Loading...
HomeMy WebLinkAbout2020-01-20-I09 Stratford Crossing Light Industrial_Site Plan AGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: January 20, 2020 AGENDA ITEM: Consideration of approval of a resolution approving a site plan for Stratford Crossing Light Industrial FORMAT: Resolution SYNOPSIS INCLUDING PRO & CON: Element 119, requests approval of a site plan to allow for the construction of an 18,870 square feet multi-tenant commercial building. The site plan identifies four (4) tenant spaces within the building. Access to the site is provided via NW Sunrise Drive. The applicant has provided elevations for the proposed building on the site, which meets the intent of the architectural guidelines within the Site Plan Ordinance. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning Commission reviewed this project at the January 14, 2020 Commission Meeting and recommended approval subject to remaining staff comments: Approval of a Site Plan for Stratford crossing Light Industrial (220 NW Sunrise Drive) City Planner, Melissa DeBoer, introduced the request for approval of a site plan for a commercial/office building as submitted by the applicant, Stratford Crossing, LLC. The subject property is generally located south of NW Gettysburg Lane and west of NW 10th Street, containing approximately 1.10 acres. For reference, the recently approved Kinship Brewing Company site is located directly east of the site. Mrs. DeBoer advised that the site plan identifies one building 18,870 square feet in size to function as an office warehouse building. A monument sign is proposed on the south side of the access drive and the trash enclosure is on the south side of the parking area. Access to the site will be provided on the east side of the property from NW Sunrise Drive. Public Utilities are available to the site, and storm water management is proposed in a dry bottom retention pond on the south west of the site. All open- space, landscaping, parking, and lighting plans meet the requirements of the Site Plan Ordinance. At this time staff would recommend approval for the site plan for Stratford Crossing Light Industrial.  Commissioner Tietz questioned if the overhead doors meant anticipated Semi Truck traffic in the area. Mrs. DeBoer advised that they were more to keep the options open for tenants. The building use and style is much like the I-80 West Industrial Park south of town for reference. I9  Commissioner Koshy questioned if the doors are facing south. Mrs. DeBoer advised that was correct.  Commissioner Broderick questioned where the trash location was on the plan. Mrs. DeBoer highlighted the location on the south side of the site center of the parking lot.  Commissioner Tietz questioned if there were any identified tenants. Mrs. DeBoer advised that none were called out at this time. Commissioner Hoifeldt moved to approve a Site Plan for Stratford Crossing Light Industrial (220 NW Sunrise Drive). Commissioner Broderick seconded the motion. . Ayes: Ward, Tietz, Streit, Broderick, Koshy and Freund. Nays: None. Recused: Hoifeldt. Motion Carries. STAFF REVIEW AND COMMENT: Staff recommends approval of the site plan. RECOMMENDATION: Approve the resolution. ATTACHMENTS: I. Proposed Resolution II. Staff Report III. Site Plan & Elevations PREPARED BY: Andy Kass, Senior Planner REVIEWED BY: THE CITY OF WAUKEE, IOWA RESOLUTION 20- APPROVING THE SITE PLAN FOR STRATFORD CROSSING LIGHT INDUSTRIAL (220 NW SUNRISE DRIVE) IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Site Plan for Stratford Crossing Light Industrial, subject to remaining staff comments on January 14, 2020; AND, WHEREAS, the Site Plan for Stratford Crossing Light Industrial is in general conformance with §160 – Site and Building Development Standards Ordinance of the Waukee Municipal Code; AND, WHEREAS, the Site Plan for Stratford Crossing Light Industrial is in general conformance with §161 – Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND, NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 20th day of January, 2020 that the Site Plan for Stratford Crossing Light Industrial is approved. BE IT FURTHER RESOLVED that the City of Waukee does hereby accept the following easements related to the site plan to be filed with the Dallas County Recorder: 1. Public Utility Easement; and 2. Detention Easement ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Anna Bergman R. Charles Bottenberg Chris Crone Larry R. Lyon VACANT SEAT PLANNING AND ZONING COMMISSION STAFF REPORT PROJECT: Stratford Crossing Light Industrial – Site Plan PREPARED BY: Andy Kass, AICP – Senior Planner REPORT DATE: January 10, 2020 MEETING DATE: January 14, 2020 GENERAL INFORMATION Applicant / Owner: Stratford Crossing, LLC (owner) & Element 119 (applicant) Engineer: Jared Murray, Civil Design Advantage Request: The applicant is requesting approval of a site plan for a commercial/office building. Location and Size: Property is located south of NW Gettysburg Lane and east of SE Alice’s Road, containing approximately 1.10 acres. Property Address: 220 NW Sunrise Drive AREA MAP ABOVE: Aerial of subject property (outlined in RED) in relation to the surrounding area. January 9, 2020 2 of 3 LAND USES AND ZONING Location Existing Land Use Comprehensive Plan Current Zoning Property in Question Vacant – Undeveloped Light Industrial Office M-1 (Light Industrial District) North Vacant – Undeveloped Light Industrial Office M-1 (Light Industrial District) South Vacant – Undeveloped Light Industrial Office A-1 (Agricultural District) East Vacant – Undeveloped Light Industrial Office M-1 (Light Industrial District) / PD-1 (Planned Development Overlay District) West Vacant – Undeveloped Medium Density Residential A-1 (Agricultural District) HISTORY The subject property is located within Stratford Crossing Plat 4. The developer of the plat recently completed the public improvements for Plat 4, which includes ten (10) lots for light industrial development. PROJECT DESCRIPTION The site plan identifies the construction of an 18,870 square foot building. The building has an overall height of 28-feet. The primary use of the building is intended for office and warehouse space. A monument sign is proposed on the south side of the access drive. The trash enclosure is shown on the south side of the parking area. ACCESS AND PARKING Access to the site will be provided on the east side of the property from NW Sunrise Drive. The proposed building requires a total of 37 parking spaces. The site plan identifies 37 parking spaces provided across the site. SIDEWALKS/TRAILS A 5-foot-wide sidewalk will be constructed on the west side of NW Sunrise Drive as part of this project. UTILITIES Sanitary sewer and water main services exist on-site. A sand/oil separator will be installed with the project for the planned floor drains within the building. Storm water detention for the project is intended to be managed on the east side of the site within a dry bottom detention basin. Storm water will ultimately be discharged to the existing storm sewer along NW Sunrise Drive. LANDSCAPING & OPEN SPACE A minimum of 15% of the project area is required to be open space. The total amount of open space proposed is 32%. The plantings shown on the landscape plan meet the minimum requirements of the Landscape & Open Space Ordinance. The entire site will be sodded when construction is complete. January 9, 2020 3 of 3 ELEVATIONS Colored building elevations are included for review. The building is proposed to be constructed with brick, fiber cement paneling, aluminum storefront system, and glazing. Two (2) overhead doors are shown on the building and will be glazed overhead doors. The trash enclosure is shown to be constructed with brick sides and metal doors. Staff believes the proposed elevations meet the architectural requirements of the Site Plan Ordinance. PHOTOMETRIC PLAN A photometric plan for the parking lot lighting has been submitted and complies with the requirements of the Site Plan Ordinance. STAFF RECOMMENDATION Staff recommends approval of the site plan for Stratford Crossing Light Industrial. 3405 SE CROSSROADS DR. SUITE G, GRIMES, IOWA 50111PH: (515) 369-4400 Fax: (515) 369-4410CIVIL DESIGN ADVANTAGEUTILITY WARNINGDEVELOPMENT SUMMARYSUBMITTAL DATESARCHITECTPROJECT SITE ADDRESSSURVEYORZONINGOWNERINDEX OF SHEETSVICINITY MAPGENERAL LEGENDENGINEERAPPLICANTLEGAL DESCRIPTIONBENCHMARKSwww.iowaonecall.com1-800-292-8989ONE CALLIOWAONE CALLKnow what'sbefore you dig.below.CallSTRATFORD CROSSING LIGHT INDUSTRIALSTRATFORD CROSSING LIGHT INDUSTRIALSITE PLAN FOR:WAUKEE, IOWASTRATFORD CROSSING LIGHT INDUSTRIALPRELIMINARYCONSTRUCTION SCHEDULElllllllllNOTESPROJECTN 10TH STREETRACCOON RIVERVALLEY TRAILHICKMAN RD / HWY 6T AVENUE 280TH PLACECITY OF WAUKEECORPORATE LIMITSCITY OF WAUKEECORPORATE LIMITSNW STRATFORDDRIVEDRIVENW SUNRISE DETAILS CIVIL DESIGN ADVANTAGE1811.596STRATFORD CROSSING LIGHT INDUSTRIAL ENGINEER: JMM TECH: REVISIONS DATE WAUKEE, IOWA PHONE: (515) 369-4400 FAX: (515) 369-4410 3405 S.E. CROSSROADS DRIVE, SUITE G GRIMES, IOWA 50111 2ND SUBMITTAL 06/11/19 3RD SUBMITTAL 07/09/19 4TH SUBMITTAL 07/22/19 5TH SUBMITTAL 09/19/19 6TH SUBMITTAL 09/30/19 FINAL SUBMITTAL 12/12/19 2.0TYPICAL RIGHT OF WAY GRADING FOR DEPRESSED SIDEWALK LOCATIONSHYDRANT ASSEMBLY DETAILHYDRANT ASSEMBLY DETAILDETECTABLE WARNING DETAILRCP APRON FOOTING DETAILCLASS 'A' CURB AND SIDEWALKCURB RAMP FORCLASS B OR C SIDEWALKSPOT ELEVATION REFERENCE DETAILINTEGRAL 6" STANDARD CURBST-2 ORIFICE PLATE DETAIL12" SUBGRADE PREPARATIONDOWNSPOUT CONNECTION WITH WYE DETAILS CIVIL DESIGN ADVANTAGE1811.596STRATFORD CROSSING LIGHT INDUSTRIAL ENGINEER: JMM TECH: REVISIONS DATE WAUKEE, IOWA PHONE: (515) 369-4400 FAX: (515) 369-4410 3405 S.E. CROSSROADS DRIVE, SUITE G GRIMES, IOWA 50111 2ND SUBMITTAL 06/11/19 3RD SUBMITTAL 07/09/19 4TH SUBMITTAL 07/22/19 5TH SUBMITTAL 09/19/19 6TH SUBMITTAL 09/30/19 FINAL SUBMITTAL 12/12/19 2.1SW-513 INTAKE (ST-1)PCC FLUME DETAILRAMP 'E' DETAILRAMP 'D' DETAILRAMP 'C' DETAILRAMP 'A' DETAILRAMP 'B' DETAILDUMPSTER ENCLOSURE DETAIL4' CHAIN LINK FENCE NW SUNRISE DRIVENW SUNRISE DRIVE 3.0DIMENSION AND GRADING PLAN DIMENSION PLANCIVIL DESIGN ADVANTAGE1811.596STRATFORD CROSSING LIGHT INDUSTRIAL ENGINEER: JMM TECH: REVISIONS DATE WAUKEE, IOWA PHONE: (515) 369-4400 FAX: (515) 369-4410 3405 S.E. CROSSROADS DRIVE, SUITE G GRIMES, IOWA 50111 2ND SUBMITTAL 06/11/19 3RD SUBMITTAL 07/09/19 4TH SUBMITTAL 07/22/19 5TH SUBMITTAL 09/19/19 6TH SUBMITTAL 09/30/19 FINAL SUBMITTAL 12/12/19GRADING PLANGENERAL NOTESTRAFFIC CONTROL NOTESPAVEMENT THICKNESSGRADING NOTES NW SUNRISE DRIVENW SUNRISE DRIVE 4.0UTILITY AND LANDSCAPE PLAN UTILITY PLANCIVIL DESIGN ADVANTAGE1811.596STRATFORD CROSSING LIGHT INDUSTRIAL ENGINEER: JMM TECH: REVISIONS DATE WAUKEE, IOWA PHONE: (515) 369-4400 FAX: (515) 369-4410 3405 S.E. CROSSROADS DRIVE, SUITE G GRIMES, IOWA 50111 2ND SUBMITTAL 06/11/19 3RD SUBMITTAL 07/09/19 4TH SUBMITTAL 07/22/19 5TH SUBMITTAL 09/19/19 6TH SUBMITTAL 09/30/19 FINAL SUBMITTAL 12/12/19LANDSCAPE PLANUTILITY NOTESSITE LANDSCAPE REQUIREMENTSMINIMUM PLANTING REQUIREMENTSLANDSCAPE NOTES RTSB #1l lllllllllllllllllllll llllllllllllllllllllll l l l lllllllllllll lllll lllllDA #11.19 ACEROSION AND SEDIMENT CONTROL PLANRTSB #llllSWPPP LEGENDstratford crossing light industrialVICINITY MAPWAUKEE, IOWAstratford crossing light industrialDISCHARGE POINT SUMMARYSTABILIZATION QUANTITIESCIVIL DESIGN ADVANTAGE1811.596STRATFORD CROSSING LIGHT INDUSTRIAL ENGINEER: JMM TECH: REVISIONS DATE WAUKEE, IOWA PHONE: (515) 369-4400 FAX: (515) 369-4410 3405 S.E. CROSSROADS DRIVE, SUITE G GRIMES, IOWA 50111NOTES:PROJECTN 10TH STREETRACCOON RIVERVALLEY TRAILHICKMAN RD / HWY 6T AVENUE 280TH PLACECITY OF WAUKEECORPORATE LIMITSCITY OF WAUKEECORPORATE LIMITSNW STRATFORDDRIVEDRIVENW SUNRISETEMPORARY STAND PIPE DETAIL5.0EROSION AND SEDIMENT CONTROL PLAN 2ND SUBMITTAL 06/11/19 3RD SUBMITTAL 07/09/19 4TH SUBMITTAL 07/22/19 5TH SUBMITTAL 09/19/19 6TH SUBMITTAL 09/30/19 FINAL SUBMITTAL 12/12/19 John B. Overton Signature DateRegistration Expires: 6/30/2019 Sheets covered by this seal: -I hereby certify that the portion of this technicalsubmission was prepared by me or under my directsupervision and responsible charge. I am duly alicensed architect under the laws of the State ofIowa.PLUM DESIGN SERVICE, INC. ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS. WE ARE NOT A LICENSED ARCHITECT OR ENGINEER. THESE PLANS ARE PROVIDED ON AN "AS IS" BASIS AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND/OR OWNER TO VERIFY AND CHECK ALL NOTES, DETAILS, ELEVATIONS, SECTIONS, AND FLOOR PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR AND/OR OWNER SHALL NOTIFY PLUM DESIGN SERVICE, INC. IMMEDIATELY IF ANY ERRORS OR OMISSION FOR POSSIBLE CORRECTION ARE IDENTIFIED PRIOR TO START OF CONSTRUCTION. NO WARRANTIES EXPRESS OR IMPLIED INCLUDING COMPLIANCE WITH THIS PLAN WITH APPLICABLE BUILDING CODES REQUIREMENTS ARE MADE.DATE:DATE:DATE:PROJECT ID:1100 SE ALICE'S ROAD. WAUKEE, IOWA 50263PLUM DESIGN SERVICESDATE:DATE:DATE:ISSUE DATE:DATE:DATE:TELEPHONE 515 978 6260 FAX 515 978 6261THIS PAGE IS INTENDED TO BE PRINTED ON 24"X36" PAPER TO BE TO SCALEDATE: 12" = 1'-0"A0Cover PagePDS 4305Element 119Offices01-22-1902-07-1902-18-1904-24-1905-07-1907-23-19DRAWING LISTA0 Cover PageA1 Building Code ReviewA2 Accessibility StandardsA3 Code Review - Area & Occupancy/ Egress & ADAA4 Code Review - SeparationA5 Wall Types / Door ScheduleA6 ElevationsA7 ElevationsA9 First FloorA10 MezzanineA11 Reflected CeilingA12 Building SectionsA13 Building SectionsA14 Building SectionsARCHITECTURALSTRUCTURALCivil EngineerMechanical ContractorElectrical ContractorPlumbing ContractorSprinkler Systems ContractorHVAC - Plumbing - Electrical -Design / Energy ReviewAPPLICABLE CODES (CITY OF XXXX, IOWA)ELEMENT 119OFFICESPROJECT ADDRESSPROJECT TEAMSHEET INDEXPROJECT LOCATIONBUILDING DATAVICINITY LOCATIONGROSS AREA SCHEDULENAME SQ FTMain Floor 15200 SF15200 SFElement 119 Mezzanine 623 SFStratford Mezzanine 628 SF1251 SFGrand total 16451 SFBUILDING DATACompany NameCompany AddressPH:FX:Plum Building Systems1100 SE Alice's RoadWaukee, IowaPH: 515-978-6260Company NameCompany AddressPH:FX:Company NameCompany AddressPH:FX:Company NameContractor NamePH:FX:Company NameCompany AddressPH:FX:Company NameCompany AddressPH:FX:Company NameContractor NamePH:FX:WebsiteCompany NameEngineer NameCompany AddressPH:FX: WebsiteNew Construction: 1 Story w/ MezzanineType of Construction: BBuilding Height: 28' 8 13/16"NFPA-13 Sprinkler SystemPAGE NO.PAGE NAMESTRUCTURAL DRAWING LIST1. BUILDINGINTERNATIONAL BUILDING CODE 2015 EDITION, WITH LOCAL AMMENDMENTS2. FIREINTERNATIONAL FIRE CODE 2015 EDITION, WITH LOCAL AMMENDMENTS3. MECHANICALINTERNATIONAL MECHANICAL CODE 2015 EDITION, WITH LOCAL AMMENDMENTS4. ELECTRICALNATIONAL ELECTRICAL CODE XXXX EDITION WITH STATE AMMENDMENTS5. PLUMBING2015 INTERNATIONAL PLUMBING CODE, WITH LOCAL AMMENDMENTS6. ENERGY2012 INTERNATIONAL ENERGY AND CONSERVATION CODE,WITH LOCAL AND STATE AMMENDMENTS7. FUEL GAS CODEINTERNATIONAL FUEL CODE 2015 EDITION8. ICC/ANSI.A117.1 2009 (ADA STANDARDS)2010 ADA STANDARDS FOR ACCESSIBLE DESIGNFIRE ALRM AND SUPPRESSION PLANS TO BE SUBMITTED TO FIRE MARHSALL OFFICE FOR REVIEW AND APPROVAL PLUM DESIGN SERVICE, INC. ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS. WE ARE NOT A LICENSED ARCHITECT OR ENGINEER. THESE PLANS ARE PROVIDED ON AN "AS IS" BASIS AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND/OR OWNER TO VERIFY AND CHECK ALL NOTES, DETAILS, ELEVATIONS, SECTIONS, AND FLOOR PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR AND/OR OWNER SHALL NOTIFY PLUM DESIGN SERVICE, INC. IMMEDIATELY IF ANY ERRORS OR OMISSION FOR POSSIBLE CORRECTION ARE IDENTIFIED PRIOR TO START OF CONSTRUCTION. NO WARRANTIES EXPRESS OR IMPLIED INCLUDING COMPLIANCE WITH THIS PLAN WITH APPLICABLE BUILDING CODES REQUIREMENTS ARE MADE.DATE:DATE:DATE:PROJECT ID:1100 SE ALICE'S ROAD. WAUKEE, IOWA 50263PLUM DESIGN SERVICESDATE:DATE:DATE:ISSUE DATE:DATE:DATE:TELEPHONE 515 978 6260 FAX 515 978 6261THIS PAGE IS INTENDED TO BE PRINTED ON 24"X36" PAPER TO BE TO SCALEDATE:A1Building CodeReviewPDS 4305Element 119Offices01-22-1902-07-1902-18-1904-24-1905-07-1907-23-19 12¼¼½48 min30 min760122030 min48 min30 min48 min(a)forward(b)parallel36 min48 min24 max32 min32 min36 min24 max(c)folding door(a)hinged door(b)sliding door32 min 32 min32 min90°48 min48 min(a) (b)48 min(c)17"-25"9"6" max30" min(a)elevation(b)plan11" min27" min8" min9" min(a)elevation(b)plan30" min25" max60 min18 min(a)front approach, pull side(b)front approach, push side3' - 0"MIN.4' - 0"48 min12 min(c)front approach, push side, doorprovided with both closer and latch36 min60 min(d)hinge approach, pull side42 min54 min(e)hinge approach, pull side42 min22 min(f)hinge approach, push side(g)hinge approach, push side, doorprovided with both closer and latch48 min22" min12" min24 min48 min(h)latch approach, pull side(i)latch approach, pull side,door provided with closer54 min24 min24 min42 min(j)latch approach, push side(k)latch approach, push side,door provided with closer24 min48 min60 min24 min36 min36 min12 min 12 min60 minbasearmarmM I N ø 5 ' - 0 "T-TURN REQUIREMENTS CIRCULAR>20-25 max20 maxMIN4' - 0"27" MINMAX4' - 0"MIN4' - 0"27" MIN44" MAX10 max48 max34 max34 max46 max> 10-24 max(a) (b)MAX1/4"1/2" MAX1/4" MAXCONCRETESTOOPINTERIORLOW PROFILE THRESHOLDDOOREXTERIORMAX 1:2 SLOPE1/8" PER FOOTMAXIMUM SLOPE36 minX > 2461091560 minX > 15152538010 max255122048 max15 min38034-38(a)stairs(b)ramps34-38(c)walking surfaces34-381½ min1½ min12 min12 min12 min12 minMAX3' - 0"MIN2' - 3"MIN9"17" TO 19"MAX6"MIN8"TOE CLEARANCEKNEE CLEARANCEEQUIPMENT ALLOWED IN SHADED AREA-FORWARD CLEAR FLOOR SPACE / CENTER ON UNIT-KNEE AND TOE CLEARANCE COMPLY TO SECTION 30638" TO 43"36" MAX.1' - 6"CLEAR FLOOR SPACEMIN3' - 0"MAX6"MAX1' - 0"MIN3' - 6"5' - 0" MIN4' - 8" MINSINK7" TO 9"MAX1' - 0"MIN3' - 6"33" - 36"MIN1' - 6"24" MIN TO 42" MAXMIN1' - 6"39" MIN TO 41" MAX39" MIN TO 41" MAXMIN17" TO 19"WOOD BLOCKINGFOR GRAB BARStransfer side1' - 6"MIN1' - 5"MIN3' - 0"MAX6"MIN2' - 0"MIN1' - 0"33" - 36"WOOD BLOCKINGFOR GRAB BARS(b)stall type(a)wall hung type17 max13½ min13½ minMIN2' - 3"MIN9"1'-5" MINMAX6"MIN8"TOE CLEARANCEKNEE CLEARANCEMAX2' - 10"MIN2' - 5"MAX TO BOTTOM OF MIRROR3' - 4"MAX4' - 0"SOAP DISPENSER44" MAX IF OVER SINK1. PAPER TOWEL AND DRYER48" MAX TO HIGHEST OPERABLE PART2. ADA CLEARANCE WRAP PIPESPLUM DESIGN SERVICE, INC. ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS. WE ARE NOT A LICENSED ARCHITECT OR ENGINEER. THESE PLANS ARE PROVIDED ON AN "AS IS" BASIS AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND/OR OWNER TO VERIFY AND CHECK ALL NOTES, DETAILS, ELEVATIONS, SECTIONS, AND FLOOR PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR AND/OR OWNER SHALL NOTIFY PLUM DESIGN SERVICE, INC. IMMEDIATELY IF ANY ERRORS OR OMISSION FOR POSSIBLE CORRECTION ARE IDENTIFIED PRIOR TO START OF CONSTRUCTION. NO WARRANTIES EXPRESS OR IMPLIED INCLUDING COMPLIANCE WITH THIS PLAN WITH APPLICABLE BUILDING CODES REQUIREMENTS ARE MADE.DATE:DATE:DATE:PROJECT ID:1100 SE ALICE'S ROAD. WAUKEE, IOWA 50263PLUM DESIGN SERVICESDATE:DATE:DATE:ISSUE DATE:DATE:DATE:TELEPHONE 515 978 6260 FAX 515 978 6261THIS PAGE IS INTENDED TO BE PRINTED ON 24"X36" PAPER TO BE TO SCALEDATE:As indicatedA2AccessibilityStandardsPDS 4305Element 119Offices01-22-1902-07-1902-18-1904-24-1905-07-1907-23-19Scale: 3" = 1'-0"2Beveled Change in LevelScale: 1/4" = 1'-0"3Clear Floor or Ground SpaceScale: 1/4" = 1'-0"4Position of Clear Floor or GroundSpaceScale: 1/4" = 1'-0"7Clear Width of an Accessible RouteScale: 1/4" = 1'-0"8Clear Width of DoorwaysScale: 1/4" = 1'-0"11Doors in Series and Gates in SeriesScale: 1/4" = 1'-0"17Toe ClearanceScale: 1/4" = 1'-0"18Knee ClearanceCHAPTER 3-BUILDING BLOCKSCHAPTER 4-ACCESSIBLE ROUTESScale: 1/4" = 1'-0"9Maneuvering Clearance at ManualSwinging DoorsScale: 1/4" = 1'-0"10Maneuvering Clearance at ManualSwinging DoorsScale: 1/4" = 1'-0"20Maneuvering Clearance at ManualSwinging DoorsScale: 1/4" = 1'-0"21Maneuvering Clearance at ManualSwinging DoorsScale: 1/4" = 1'-0"22Maneuvering Clearance at ManualSwinging DoorsScale: 1/4" = 1'-0"23Maneuvering Clearance at ManualSwinging DoorsScale: 1/4" = 1'-0"24Maneuvering Clearance at ManualSwinging DoorsScale: 1/4" = 1'-0"25Maneuvering Clearance at ManualSwinging DoorsScale: 1/4" = 1'-0"26Maneuvering Clearance at ManualSwinging DoorsScale: 1/4" = 1'-0"27Maneuvering Clearance at ManualSwinging DoorsScale: 1/4" = 1'-0"28Maneuvering Clearance at ManualSwinging DoorsScale: 1/4" = 1'-0"29Turning SpaceScale: 1/4" = 1'-0"30Obstructed High Forward ReachScale: 1/4" = 1'-0"6Obstructed High Side ReachCHAPTER 5 GENERAL SITE AND BUILDING ELEMENTSNOTES:1. PAGE A2 IS PROVIDED FOR GENERAL REFERENCE. IT IS THE BUILDER/CONTRACTOR'S RESPONSIBILITY TO VERIFY AND COMPLY WITH ALL CURRENT CODES, ORDINANCES, AND/OR LAWS GOVERNING THIS PROJECT. REFER TO LOCAL JURISDICTION FOR ANY MODIFICATIONS AND/OR AMENDMENTS.REFERENCE STANDARDS:2010 AMERICAN WITH DISABILITIES ACT STANDARDS FOR ACCESSIBLE DESIGN2009 ACCESSIBLE AND USEABLE BUILDING AND FACILITIES (ICC A117.1-2009)FLOOR OR GROUND SURFACES SHALL BE STABLE, FIRM AND SLIP RESISTANT AND SHALL COMPLY WITH ADA/ANSI 302CARPET OR CARPET TILE SHALL COMPLY WITH ADA/ANSI 302.2OPENING IN FLOORS OR GROUND SURFACES SHALL COMPLY WITH ADA/ANSI 302.3CHANGES IN LEVEL SHALL COMPLY WITH ADA/ANSI 303Scale: 1 1/2" = 1'-0"1Vertical Change in Level-ExteriorDoor1. THRESHOLDS AT DOORWAYS SHALL BE 1/2" MAX IN HEIGHT. RAISED THRESHOLDS AND CHANGE IN LEVEL AT DOORWAYS SHALL COMPLY WITH ADA/ANSI 302 AND 3022. DOOR HARDWARE- HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERABLE PARTS ON A DOOR AND GATES SHALL COMPLY WITH ADA/ANSI 309.4. OPERABLE PARTS OF SUCH SHALL BE 34" MINIMUM AND 48" MAXIMUM ABOVE FINISH FLOOR OR GROUND3. DOOR CLOSURES SHALL COMPLY WITH ADA 404.2.8/ANSI 404.2.7Scale: 1/4" = 1'-0"5Maneuvering Clearance in anAlcove , Forward ApproachScale: 1/4" = 1'-0"12Maneuvering Clearance in anAlcove, Parallel ApproachScale: 1/4" = 1'-0"13Unobstructed Side ReachScale: 1/4" = 1'-0"14Handrail HeightScale: 3/8" = 1'-0"15Handrail ClearanceScale: 3/8" = 1'-0"16Horizontal Projections BelowGripping SurfaceScale: 1/4" = 1'-0"19Top and Bottom Handrail Extensionat RampsScale: 1/4" = 1'-0"31Top Handrail Extension at StairsScale: 1/4" = 1'-0"32Bottom Handrail Extension atStairsCHAPTER 6 PLUMBING ELEMENTS- PUBLIC SPACESScale: 3/8" = 1'-0"33Drinking Fountain Spout LocationScale: 3/8" = 1'-0"34SIZE & CLEARANCE OF WATERCLOSETSScale: 3/8" = 1'-0"35Side Wall Grab Bar at Water ClosetsScale: 3/8" = 1'-0"36Rear Wall Grab Bar at WaterClosetsScale: 1/4" = 1'-0"37Height and Depth of UrinalsScale: 3/8" = 1'-0"39Lavatories and Sink-SideView-Common-Public Areas 3627 SFElement 1193627 SFStratford3627 SFOpen Tenant4320 SFLaw Office628 SFStratford Mezzanine623 SFElement 119 MezzanineFIRE EXTINGUISHER1/3 = 30' - 7 13/16"91' - 11 7/16"1/3 = 30' - 7 13/16"91' - 11 7/16"1/3 = 30' - 7 13/16"91' - 11 7/16"1/3 = 32' - 2 5/64"96' - 6 1/4"FIRE EXTINGUISHERFIRE EXTINGUISHERFIRE EXTINGUISHER79' - 8 9/16"79' - 8 11/16"7 9 ' - 8 1 /4 "79' - 0"EXIT SIGNEXIT SIGNEXIT SIGNEXIT SIGNEXIT SIGNEXIT SIGNEXIT SIGNEXIT SIGNELEMENT 119STRATFORDOPEN TENANTLAW OFFICESTRATFORDMEZZANINEELEMENT 119MEZZANINEPLUM DESIGN SERVICE, INC. ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS. WE ARE NOT A LICENSED ARCHITECT OR ENGINEER. THESE PLANS ARE PROVIDED ON AN "AS IS" BASIS AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND/OR OWNER TO VERIFY AND CHECK ALL NOTES, DETAILS, ELEVATIONS, SECTIONS, AND FLOOR PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR AND/OR OWNER SHALL NOTIFY PLUM DESIGN SERVICE, INC. IMMEDIATELY IF ANY ERRORS OR OMISSION FOR POSSIBLE CORRECTION ARE IDENTIFIED PRIOR TO START OF CONSTRUCTION. NO WARRANTIES EXPRESS OR IMPLIED INCLUDING COMPLIANCE WITH THIS PLAN WITH APPLICABLE BUILDING CODES REQUIREMENTS ARE MADE.DATE:DATE:DATE:PROJECT ID:1100 SE ALICE'S ROAD. WAUKEE, IOWA 50263PLUM DESIGN SERVICESDATE:DATE:DATE:ISSUE DATE:DATE:DATE:TELEPHONE 515 978 6260 FAX 515 978 6261THIS PAGE IS INTENDED TO BE PRINTED ON 24"X36" PAPER TO BE TO SCALEDATE:As indicatedA3Code Review - Area& Occupancy /Egress & ADAPDS 4305Element 119Offices01-22-1902-07-1902-18-1904-24-1905-07-1907-23-19UNIT GROSS AREA BREAKOUTScale: 1" = 20'-0"1First Floor Unit Gross AreasScale: 1" = 20'-0"2Mezzanine Unit Gross AreasTOTAL TRAVEL EGRESS DISTANCEType EXIT ROUTE DISTANCEElement 11901 Start Path A 14' - 3"02 Middle Path A 100' - 0"03 End Path A 15' - 6"129' - 9"Stratford01 Start Path B 14' - 10"02 Middle Path B 58' - 4"03 End Path B 44' - 7"117' - 9"EXIT ACCESS TRAVEL DISTANCE- MAX. DISTANCE= 250 FEET (SPRINKLER)1. EXIT SIGNS PER SECTION 10132. STAIR IDENTIFICATION PER SECTION 1023.93. PROVIDE PORTABLE TYPE 2-A FIRE EXTINGUISHERS AS REQUIRED INLIGHT (LOW) HAZARD AREAS TO MEET NFPA 10 AND THE FOLLOWING CONDITIONS:1. MAXIMUM FLOOR AREA PER EXTINGUISHER IS 6,000 SF2. MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER IS 75 FEET3. CABINET TO BE RECESSED / MAINTAIN 1 HOUR RATING PARTITION RATING / NOT TO PROJECT MORE THAN 4" FROM THE FACE OF WALL4. PROVIDE MEANS OF EGRESS ILLUMINATION AT MEANS OF EGRESS LOCATIONS (CORRIDORS AND STAIRS) IN ACCORDANCE WITH SECTION 1008.2 AND 1008.3TOTAL COMMON PATH OF EGRESS TRAVELType EXIT ROUTE DISTANCEElement 11901 Start Path A 13' - 3"02 Middle Path A 49' - 1"03 End Path A 4' - 7"66' - 11"Stratford01 Start Path B 13' - 10"02 Middle Path B 33' - 4"03 End Path B 15' - 7"62' - 9"COMMON PATH OF EGRESS TRAVEL- MAX. DISTANCE = 75 FEET Scale: 3/32" = 1'-0"3First Floor - Egress & ADAClearanceScale: 3/32" = 1'-0"4Mezzanine - Egress & ADAClearanceEGRESS & ADAUNIT GROSS AREA SCHEDULENAME SQ. FT.Element 119 3627 SFElement 119 Mezzanine 623 SF4250 SFStratford 3627 SFStratford Mezzanine 628 SF4255 SFOpen Tenant 3627 SF3627 SFLaw Office 4320 SF4320 SFGrand total 16451 SF UPUP5522113344AABBFIRE DEPARTMENT CONNECTION (FDC). PROVIDE METAL SIGN WITH 1" RAISED LETTERS MIN. AT EXTERIOR WALL.COORDINATE LOCATION WITH PLUMBING CONTRACTOR.PLUM DESIGN SERVICE, INC. ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS. WE ARE NOT A LICENSED ARCHITECT OR ENGINEER. THESE PLANS ARE PROVIDED ON AN "AS IS" BASIS AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND/OR OWNER TO VERIFY AND CHECK ALL NOTES, DETAILS, ELEVATIONS, SECTIONS, AND FLOOR PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR AND/OR OWNER SHALL NOTIFY PLUM DESIGN SERVICE, INC. IMMEDIATELY IF ANY ERRORS OR OMISSION FOR POSSIBLE CORRECTION ARE IDENTIFIED PRIOR TO START OF CONSTRUCTION. NO WARRANTIES EXPRESS OR IMPLIED INCLUDING COMPLIANCE WITH THIS PLAN WITH APPLICABLE BUILDING CODES REQUIREMENTS ARE MADE.DATE:DATE:DATE:PROJECT ID:1100 SE ALICE'S ROAD. WAUKEE, IOWA 50263PLUM DESIGN SERVICESDATE:DATE:DATE:ISSUE DATE:DATE:DATE:TELEPHONE 515 978 6260 FAX 515 978 6261THIS PAGE IS INTENDED TO BE PRINTED ON 24"X36" PAPER TO BE TO SCALEDATE: 3/32" = 1'-0"A4Code Review -SeparationPDS 4305Element 119Offices01-22-1902-07-1902-18-1904-24-1905-07-1907-23-19OCCUPANCY TYPE: XXCONSTRUCTION TYPE: XXNFPA-13 SPRINKLER SYSTEMSEPARATION LEGEND:0-FB = 0 HOUR FIRE BARRIER1-FR = 1 HOUR FIRE RESISTANCE RATING- FROM INSIDSE OF BUILDING1-FRX = 1 HOUR FIRE RESISTANCE RATING- FROM OUTSIDE OF BUILDING1-FB = 1 HOUR FIRE BARRIER1-FP = 1 HOUR FIRE PARTITIONScale: 3/32" = 1'-0"1First Floor - Vertical Separation INTERIOR OF UNITSINTERIOR OF UNITSTENANT SEPARATION WALL:-5/8" TYPE X GYP. BOARD-7/16" OSB-2X6 DF STUDS @ 16" O/C / 2X6 SPF PLATES-R-19 BATT INSULATION-1/2" RESILIENT CHANNEL @ 16" O/C-5/8" TYPE X GYP. BOARD-ACOUSTICAL SEALANT @ TOP AND BOTTOM OF GYP.PARTITION WALL:2X4 WALLS-5/8" GYP. BOARD -2X4 DF STUDS @ 16" O/C / 2X4 SPF PLATES-5/8" GYP. BOARDPARTITION WALL:2X6 WALLS-5/8" GYP. BOARD -2X6 DF STUDS @ 16" O/C / 2X6 SPF PLATES-5/8" GYP. BOARD1210 11INTERIOR OF UNITSINTERIOR OF UNITSINTERIOR OF UNITSINTERIOR OF UNITS5/8"7/16"5 1/2"1/2"5/8"7 11/16"6 3/4"5/8"5 1/2"5/8"5/8"3 1/2"5/8"4 3/4"FIRE RATING: 1 HR - UL RATING NO. - U305STC RATING: STC 34FIRE RATING: 1 HR - UL RATING NO. - U327STC RATING: STC 50FIRE RATING: 1 HR - UL RATING NO. - U305STC RATING: STC 34ROOF ASSEMBLY1 HOUR - UL RATING NO. - UL L558 / GA FILE # FC 5514-1/2" OSB SHEATHING-ROOF TRUSS @ 24" O/C MAX. SPACING-ACOUSTICAL BATT INSULATION-1/2" RESILIENT CHANNEL @ 12" O/C PERPENDICULAR TO TRUSSES- 5/8" TYPE C GYP. BOARD-DUCT & DAMPERS ALLOWED11FLOOR ASSEMBLYSTAIR AREA-3/4" GYP. CRETE-3/4" OSB T & G SHEATHING-2X10 JOIST 16" O/C.-1/2" RESILIENT CHANNELS @ 16" O/C PERPENDICULAR TO JOIST- 5/8" TYPE C GYP. BOARD15FLOOR HGT.11 7/8"5/8"1/2"9 1/4"3/4"3/4"FIRE RATING: 1 HOUR - UL RATING NO. - L523STC RATING:EXTERIORINTERIOREXTERIOR WALL:BRICK- STONE OR THIN BRICK VENEER-SCRATCH COAT/BOND COAT-GALV. METAL LATH-1/2" DRAINAGE / RAINSCREEN MAT-BUILDING WEATHER WRAP-7/16" OSB-2X6 DF STUDS @ 16" O/C / 2X6 SPF PLATES-R-21 BATT INSULATION-5/8" GYP. TYPE X11/2"5 1/2"5/8"6 5/8"EXTERIOR WALL:CMU BLOCK21/2"5 1/2"5/8"- CMU BLOCK-SCRATCH COAT/BOND COAT-GALV. METAL LATH-1/2" DRAINAGE / RAINSCREEN MAT-BUILDING WEATHER WRAP-7/16" OSB-2X6 DF STUDS @ 16" O/C / 2X6 SPF PLATES-R-21 BATT INSULATION-5/8" GYP. TYPE XEXTERIORINTERIORFIRE RATING: 1 HR (INTERIOR SIDE ONLY) - UL RATING NO. - U356 STC RATING:FIRE RATING:STC RATING:EXTERIORINTERIOREXTERIOR WALL:HARDIPLANK - TIMBER BARK-HARDIPLAN/ SEE ELEV FOR HORZ/VERTICAL-BUILDING WEATHER WRAP-7/16" OSB-2X6 DF STUDS @ 16" O/C / 2X6 SPF PLATES-R-21 BATT INSULATION-5/8" GYP. TYPE X OVER 6 MIL POLY VAPOR BARRIER31/2"5 1/2"5/8"6 5/8"FIRE RATING: 1 HR (INTERIOR SIDE ONLY) - UL RATING NO. - U356 STC RATING:EXTERIORINTERIOREXTERIOR WALL:HARDI REVEAL PANEL - AGED PEWTER-STUCCO-SCRATCH COAT/BOND COAT-GALV. METAL LATH-1/2" DRAINAGE / RAINSCREEN MAT-BUILDING WEATHER WRAP-7/16" OSB-2X6 DF STUDS @ 16" O/C / 2X6 SPF PLATES-R-21 BATT INSULATION-5/8" GYP. TYPE X OVER 6 MIL POLY VAPOR BARRIER41/2"5 1/2"5/8"6 5/8"FIRE RATING: 1 HR (INTERIOR SIDE ONLY) - UL RATING NO. - U356 STC RATING:HARDWARE SCHEDULETYPE 1DOOR PANEL TYPESGROUP A: EXTERIOR DOORS-KEYED CYLINDER-ELECTRIC STRIKE-ADA COMPLIANT THRESHOLD-CLOSER/ MAX PULL 5 LBS-WALL STOP (WALL OR HINGE)-EXITING DEVICE - PANIC HARDWAREGROUP B: COMMON DOORS-PASSAGE LOCKSET-WALL STOP (WALL OR HINGE)-KICK PLATE1. LOCATE ACCESSIBLE HARDWARE BETWEEN 34" AND 48" ABOVE FINISHED FLOOR.2. ALL GLAZING IN DOORS AND SIDELIGHTS TO BE SAFETY GLASS TO MEET CODE.STOREFRONT ENTRY DOOR - SINGLEVARIESVARIESVARIESVARIESTVARIES6' - 5"TTVARIESVARIESTYPE 2STOREFRONT ENTRY DOOR - DOUBLETYPE 3EXTERIOR OVERHEAD GARAGE DOORTYPE 4SOLID CORE DOOR W/ REDIFRAME PREFINISHED STEEL FRAMES AND PREFINISHED STEEL CASING.DOOR AND FRAME TO BE RATED AS NOTED ON DOOR SCHEDULEVARIESVARIESTYPE 5INTERIOR REDIFRAMEDOOR - SINGLEPLUM DESIGN SERVICE, INC. ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS. WE ARE NOT A LICENSED ARCHITECT OR ENGINEER. THESE PLANS ARE PROVIDED ON AN "AS IS" BASIS AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND/OR OWNER TO VERIFY AND CHECK ALL NOTES, DETAILS, ELEVATIONS, SECTIONS, AND FLOOR PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR AND/OR OWNER SHALL NOTIFY PLUM DESIGN SERVICE, INC. IMMEDIATELY IF ANY ERRORS OR OMISSION FOR POSSIBLE CORRECTION ARE IDENTIFIED PRIOR TO START OF CONSTRUCTION. NO WARRANTIES EXPRESS OR IMPLIED INCLUDING COMPLIANCE WITH THIS PLAN WITH APPLICABLE BUILDING CODES REQUIREMENTS ARE MADE.DATE:DATE:DATE:PROJECT ID:1100 SE ALICE'S ROAD. WAUKEE, IOWA 50263PLUM DESIGN SERVICESDATE:DATE:DATE:ISSUE DATE:DATE:DATE:TELEPHONE 515 978 6260 FAX 515 978 6261THIS PAGE IS INTENDED TO BE PRINTED ON 24"X36" PAPER TO BE TO SCALEDATE:As indicatedA5Wall Types / DoorSchedulePDS 4305Element 119Offices01-22-1902-07-1902-18-1904-24-1905-07-1907-23-19EXTERIOR WALLINTERIOR WALLFLOOR / CEILINGROOF / CEILINGFIRE RATING:STC RATING:DOOR SCHEDULEID QTY NOMINAL SIZE DOOR TYPEROUGH OPENINGS FRAMEFIRERATINGPANELHARDWAREGROUPDESCRIPTIONLEVELWidth HeightAluminumInsulated MetalWoodRediframeThresholdAluminumInsul. MetalWoodThicknessPanel - TypeGlassD1351SF2 1 Storefront●●Full First FloorD1352RSA 1 3-0 x 6-8 3' - 2 1/4" 6' - 10 3/4" 0' - 1 3/4" Verify RO First FloorElementD4 1 12-0 x 14-0 Overhead Garage Door 12' - 3" 14' - 1 1/2"Overhead Garage Door First FloorRSA 1 3-0 x 6-8 3' - 2 1/4" 6' - 10 3/4" 0' - 1 3/4" Verify RO First FloorRWA 2 3-0 x 6-8 Interior Standard 3' - 2" 6' - 10 1/2"●●0' - 1 3/4" First FloorSF2 1 Storefront●●Full First FloorLaw FirmRSA 1 3-0 x 6-8 3' - 2 1/4" 6' - 10 3/4" 0' - 1 3/4" Verify RO First FloorSF1 1 Storefront●●Full First FloorOpen TenantD4 1 12-0 x 14-0 Overhead Garage Door 12' - 3" 14' - 1 1/2"Overhead Garage Door First FloorRSA 1 3-0 x 6-8 3' - 2 1/4" 6' - 10 3/4" 0' - 1 3/4" Verify RO First FloorStratfordD4 1 12-0 x 14-0 Overhead Garage Door 12' - 3" 14' - 1 1/2"Overhead Garage Door First FloorRSA 1 3-0 x 6-8 3' - 2 1/4" 6' - 10 3/4" 0' - 1 3/4" Verify RO First FloorRWA 1 3-0 x 6-8 Interior Standard 3' - 2" 6' - 10 1/2"●●0' - 1 3/4" First FloorSF2 1 Storefront●●Full First Floor First Floor0' - 0"Front Wall Hgt20' - 8 13/16"10' - 7 1/16"1' - 0 5/8"9' - 1 1/8"2' - 6"8' - 0"First Floor Wall Hgt9' - 1 1/8"Mezzanine10' - 1 3/4"Tower Hgt28' - 8 13/16"8' - 0"20' - 8 13/16"20' - 5 5/8"190' - 4"16' - 5"21' - 7"16' - 5"24' - 0"42' - 3"24' - 6"20' - 9"24' - 5"5' - 11 1/2"12' - 0"6' - 4"12' - 0"5' - 11 1/2"4' - 4 1/2"12' - 0"4' - 4 1/2"8' - 0"HARDIE REVEAL PANEL SYSTEM - GRAY SLATEHARDIEPLANK 7 1/4" LAPSIDING W/ 6" REVEAL - COBBLE STONE HARDIEPLANK 7 1/4" LAPSIDING W/ 6" REVEAL - COBBLE STONE HARDIEPLANK 7 1/4" LAPSIDING W/ 6" REVEAL - COBBLE STONE HARDIEPLANK 7 1/4" LAPSIDING W/ 6" REVEAL - COBBLE STONE HARDIE REVEAL PANEL SYSTEM - GRAY SLATEHARDIE REVEAL PANEL SYSTEM - IRON GRAY11 1/4"8' - 0"8' - 0"8' - 0"First Floor0' - 0"T.O. Footing-4' - 0"Front Wall Hgt20' - 8 13/16"4' - 0"14' - 1 1/8"6' - 7 11/16"8' - 0"Rear Wall Hgt14' - 1 1/8"Tower Hgt28' - 8 13/16"HARDIEPLANK 8 1/4" LAPSIDING W/ 7" REVEAL - AGED PEWTERCOBBLE STONE CMU WALLTPO COATED METAL ROOF - SLATE GRAYPLUM DESIGN SERVICE, INC. ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS. WE ARE NOT A LICENSED ARCHITECT OR ENGINEER. THESE PLANS ARE PROVIDED ON AN "AS IS" BASIS AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND/OR OWNER TO VERIFY AND CHECK ALL NOTES, DETAILS, ELEVATIONS, SECTIONS, AND FLOOR PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR AND/OR OWNER SHALL NOTIFY PLUM DESIGN SERVICE, INC. IMMEDIATELY IF ANY ERRORS OR OMISSION FOR POSSIBLE CORRECTION ARE IDENTIFIED PRIOR TO START OF CONSTRUCTION. NO WARRANTIES EXPRESS OR IMPLIED INCLUDING COMPLIANCE WITH THIS PLAN WITH APPLICABLE BUILDING CODES REQUIREMENTS ARE MADE.DATE:DATE:DATE:PROJECT ID:1100 SE ALICE'S ROAD. WAUKEE, IOWA 50263PLUM DESIGN SERVICESDATE:DATE:DATE:ISSUE DATE:DATE:DATE:TELEPHONE 515 978 6260 FAX 515 978 6261THIS PAGE IS INTENDED TO BE PRINTED ON 24"X36" PAPER TO BE TO SCALEDATE: 1/8" = 1'-0"A6ElevationsPDS 4305Element 119Offices01-22-1902-07-1902-18-1904-24-1905-07-1907-23-19Scale: 1/8" = 1'-0"1FRONT ELEVATIONScale: 1/8" = 1'-0"2REAR ELEVATIONESTIMATED AREA - WALL CLADDINGMATERIAL TYPEMATERIALSFMATERIAL%MATERIALELEVATIONHardie Panel - Stucco Finish 2352 SF 23.0%Lap Siding - 6" 1545 SF 15.1%Lap Siding - 8" 5511 SF 54.0%Stone Veneer 798 SF 7.8% ROOF PLAN LEGENDSYMBOL PLATE HGT. PITCH OVERHANG HEEL HGT.---ALL RAKE OVERHANGS ARE 12" UNLESS NOTED-ROOF NOTESPROVIDE ICE SNOW BARRIER UNDER ALL VALLEYS, EVES, & ALONG ENTIRE PERIMETER OF THE ROOFPROVIDE EVEN SPACED ROOF VENTS ALONG RIDGE. COORDINATE AMOUNTS OF VENTED SOFFIT TO ENSURE PROPER AIR MOVEMENT1.2.-EACH ROOF VENT TO = 70 NET. SQ. IN.3.1:1226' - 0"METAL ROOF54' - 2"2' - 0"2' - 0"4A14First Floor0' - 0"First Floor0' - 0"T.O. Footing-4' - 0"T.O. Footing-4' - 0"Front Wall Hgt20' - 8 13/16"8' - 0"20' - 8 13/16"4' - 0"Rear Wall Hgt14' - 1 1/8"First Floor Wall Hgt9' - 1 1/8"Mezzanine10' - 1 3/4"Tower Hgt28' - 8 13/16"14' - 1 1/8"4' - 0"10' - 7 1/16"1' - 0 5/8"9' - 1 1/8"112HARDIE REVEAL PANEL SYSTEM - IRON GRAYHARDIEPLANK 8 1/4" LAPSIDING W/ 7" REVEAL - AGED PEWTERCMU WALL8' - 0"WINDOW HDR HGTFirst Floor0' - 0"First Floor0' - 0"T.O. Footing-4' - 0"T.O. Footing-4' - 0"Front Wall Hgt20' - 8 13/16"10' - 7 1/16"1' - 0 5/8"9' - 1 1/8"Rear Wall Hgt14' - 1 1/8"First Floor Wall Hgt9' - 1 1/8"Mezzanine10' - 1 3/4"Tower Hgt28' - 8 13/16"14' - 1 1/8"4' - 0"8' - 0"20' - 8 13/16"4' - 0"112HARDIEPLANK 8 1/4" LAPSIDING W/ 7" REVEAL - AGED PEWTERCMU WALL8' - 0"WINDOW HDR HGTPLUM DESIGN SERVICE, INC. ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS. WE ARE NOT A LICENSED ARCHITECT OR ENGINEER. THESE PLANS ARE PROVIDED ON AN "AS IS" BASIS AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND/OR OWNER TO VERIFY AND CHECK ALL NOTES, DETAILS, ELEVATIONS, SECTIONS, AND FLOOR PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR AND/OR OWNER SHALL NOTIFY PLUM DESIGN SERVICE, INC. IMMEDIATELY IF ANY ERRORS OR OMISSION FOR POSSIBLE CORRECTION ARE IDENTIFIED PRIOR TO START OF CONSTRUCTION. NO WARRANTIES EXPRESS OR IMPLIED INCLUDING COMPLIANCE WITH THIS PLAN WITH APPLICABLE BUILDING CODES REQUIREMENTS ARE MADE.DATE:DATE:DATE:PROJECT ID:1100 SE ALICE'S ROAD. WAUKEE, IOWA 50263PLUM DESIGN SERVICESDATE:DATE:DATE:ISSUE DATE:DATE:DATE:TELEPHONE 515 978 6260 FAX 515 978 6261THIS PAGE IS INTENDED TO BE PRINTED ON 24"X36" PAPER TO BE TO SCALEDATE:As indicatedA7ElevationsPDS 4305Element 119Offices01-22-1902-07-1902-18-1904-24-1905-07-1907-23-19Scale: 1/16" = 1'-0"3ROOF PLANESTIMATED ROOF SFWood Rafter 2'-10" - Metal Roof 15179 SFScale: 3/16" = 1'-0"1RIGHT ELEVATIONScale: 3/16" = 1'-0"2LEFT ELEVATION UPUP5522113344AABB190' - 0"45' - 4"45' - 4"45' - 4"54' - 0"80' - 0"80' - 0"190' - 0"45' - 4"45' - 4"45' - 4"54' - 0"12-0 X 14-012-0 X 14-012-0 X 14-0D4D4D419' - 11 1/2"4' - 0"4' - 0"8' - 2 1/2"HH20' - 0"7' - 0"7' - 0"20' - 0"JJJKKKK7' - 11 1/2"4' - 0"4' - 0"20' - 2 1/2"9' - 2"8' - 0 1/2"4' - 0"4' - 0"18' - 7 1/2"10' - 8"35' - 0"5 1/2"44' - 6 1/2"18' - 6"5 1/2"26' - 1 3/4"5 1/2"18' - 6"5 1/2"25' - 11"ELEMENT 119STORAGESTRATFORDSTORAGELAW OFFICE3' - 0"SF23' - 0"SF26' - 0"SF145' - 1 1/4"5 1/2"44' - 10 1/2"5 1/2"44' - 10 1/2"5 1/2"53' - 9 1/4"31' - 6"5 1/2"48' - 0 1/2"OPEN TENANTRSA3' - 0"RSA3' - 0"RSA3' - 0"22' - 8"22' - 8"RSA3' - 0"22' - 8"22' - 8"22' - 8"22' - 8"27' - 0"27' - 0"GARAGE2A12RWA3' - 0"RWA3' - 0"1A13ELEMENT 119 OFFICE9'-1 1/8" CLGSTRATFORD OFFICE9'-1 1/8" CLG3' - 6"44' - 6 1/2"11 7/8" LP 20 PLUSI-JOISTS @ 16" 0/C11 7/8" LP 20 PLUSI-JOISTS @ 16" 0/C9' - 2"1A1231' - 6"5 1/2"48' - 0 1/2"3' - 6"4' - 7"39' - 11 1/2"7' - 0"5 1/2"18' - 11"44' - 10 1/2"10' - 0"5 1/2"69' - 6 1/2"2X8 EXT. WALL2X8 EXT. WALL2X8 EXT. WALL2X8 EXT. WALLRISER RM.RWA3' - 0"NNN7' - 11 3/4"8' - 2"19' - 10 1/4"12' - 0"12' - 0"12' - 0"8' - 0"40' - 0"40' - 0"6' - 0"19' - 6"6' - 0"2A13NNN7224 F @8' - 0" HH7224 F @8' - 0" HHJJKK3' - 0"SF2RSA3' - 0"PLUM DESIGN SERVICE, INC. ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS. WE ARE NOT A LICENSED ARCHITECT OR ENGINEER. THESE PLANS ARE PROVIDED ON AN "AS IS" BASIS AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND/OR OWNER TO VERIFY AND CHECK ALL NOTES, DETAILS, ELEVATIONS, SECTIONS, AND FLOOR PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR AND/OR OWNER SHALL NOTIFY PLUM DESIGN SERVICE, INC. IMMEDIATELY IF ANY ERRORS OR OMISSION FOR POSSIBLE CORRECTION ARE IDENTIFIED PRIOR TO START OF CONSTRUCTION. NO WARRANTIES EXPRESS OR IMPLIED INCLUDING COMPLIANCE WITH THIS PLAN WITH APPLICABLE BUILDING CODES REQUIREMENTS ARE MADE.DATE:DATE:DATE:PROJECT ID:1100 SE ALICE'S ROAD. WAUKEE, IOWA 50263PLUM DESIGN SERVICESDATE:DATE:DATE:ISSUE DATE:DATE:DATE:TELEPHONE 515 978 6260 FAX 515 978 6261THIS PAGE IS INTENDED TO BE PRINTED ON 24"X36" PAPER TO BE TO SCALEDATE: 1/8" = 1'-0"A9First FloorPDS 4305Element 119Offices01-22-1902-07-1902-18-1904-24-1905-07-1907-23-19Scale: 1/8" = 1'-0"1First FloorWINDOW SCHEDULEID QTY TYPEROUGH OPENINGSHEADERHEIGHT SPECIAL NOTESWIDTH HEIGHTH 2 3684-2 CA 6' - 0" 7' - 0" 8' - 0" FixedI 2 6024 F 5' - 0" 2' - 0" 8' - 0" PictureJ 5 7224 F 6' - 0" 2' - 0" PictureK 6 3684 F 3' - 0" 7' - 0" 8' - 0" PictureN 6 4848 F 4' - 0" 4' - 0" 8' - 0" PictureDOOR SCHEDULEID QTY NOMINAL SIZE DOOR TYPEROUGH OPENINGS FRAMEFIRERATINGPANELHARDWAREGROUPDESCRIPTIONLEVELWidth HeightAluminumInsulated MetalWoodRediframeThresholdAluminumInsul. MetalWoodThicknessPanel - TypeGlassD1351SF2 1 Storefront●●Full First FloorD1352RSA 1 3-0 x 6-8 3' - 2 1/4" 6' - 10 3/4" 0' - 1 3/4" Verify RO First FloorElementD4 1 12-0 x 14-0 Overhead Garage Door 12' - 3" 14' - 1 1/2"Overhead Garage Door First FloorRSA 1 3-0 x 6-8 3' - 2 1/4" 6' - 10 3/4" 0' - 1 3/4" Verify RO First FloorRWA 2 3-0 x 6-8 Interior Standard 3' - 2" 6' - 10 1/2"●●0' - 1 3/4" First FloorSF2 1 Storefront●●Full First FloorLaw FirmRSA 1 3-0 x 6-8 3' - 2 1/4" 6' - 10 3/4" 0' - 1 3/4" Verify RO First FloorSF1 1 Storefront●●Full First FloorOpen TenantD4 1 12-0 x 14-0 Overhead Garage Door 12' - 3" 14' - 1 1/2"Overhead Garage Door First FloorRSA 1 3-0 x 6-8 3' - 2 1/4" 6' - 10 3/4" 0' - 1 3/4" Verify RO First FloorStratfordD4 1 12-0 x 14-0 Overhead Garage Door 12' - 3" 14' - 1 1/2"Overhead Garage Door First FloorRSA 1 3-0 x 6-8 3' - 2 1/4" 6' - 10 3/4" 0' - 1 3/4" Verify RO First FloorRWA 1 3-0 x 6-8 Interior Standard 3' - 2" 6' - 10 1/2"●●0' - 1 3/4" First FloorSF2 1 Storefront●●Full First Floor DNDN5522113344AABB2A121A13ROOF TRUSSES@ 24" O/CROOF TRUSSES@ 24" O/CROOF TRUSSES@ 24" O/CROOF TRUSSES@ 24" O/CSTRATFORDMEZZANINESLOPED CLGELEMENT 119MEZZANINESLOPED CLGOPEN RAILINGOPEN RAILINGOPEN RAILINGOPEN RAILINGOPEN RAILING1A1280' - 0"190' - 0"190' - 0"80' - 0"48' - 0 1/2"31' - 11 1/2"31' - 11 1/2"48' - 0 1/2"35' - 0"5 1/2"44' - 6 1/2"45' - 4"45' - 4"45' - 4"54' - 0"18' - 6"5 1/2"26' - 4 1/2"19' - 2 1/4"26' - 1 3/4"3' - 6"4' - 7"39' - 11 1/2"18' - 6"5 1/2"26' - 1 3/4"5 1/2"18' - 11 1/2"25' - 11"45' - 1 1/4"5 1/2"44' - 10 1/2"5 1/2"44' - 10 1/2"5 1/2"53' - 9 1/4"3' - 6"44' - 6 1/2"STEEL BEAMSTEEL BEAMSTEEL BEAMSTEEL BEAMSTEEL COLUMN45' - 4"45' - 4"45' - 4"54' - 0"40' - 0"40' - 0"14' - 1"4' - 5"4' - 0"14' - 11 1/2"OPEN TO BELOWOPEN TO BELOWEQEQ2X8 EXT. WALL2X8 EXT. WALL2X8 EXT. WALL2X8 EXT. WALL4A142A13PLUM DESIGN SERVICE, INC. ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS. WE ARE NOT A LICENSED ARCHITECT OR ENGINEER. THESE PLANS ARE PROVIDED ON AN "AS IS" BASIS AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND/OR OWNER TO VERIFY AND CHECK ALL NOTES, DETAILS, ELEVATIONS, SECTIONS, AND FLOOR PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR AND/OR OWNER SHALL NOTIFY PLUM DESIGN SERVICE, INC. IMMEDIATELY IF ANY ERRORS OR OMISSION FOR POSSIBLE CORRECTION ARE IDENTIFIED PRIOR TO START OF CONSTRUCTION. NO WARRANTIES EXPRESS OR IMPLIED INCLUDING COMPLIANCE WITH THIS PLAN WITH APPLICABLE BUILDING CODES REQUIREMENTS ARE MADE.DATE:DATE:DATE:PROJECT ID:1100 SE ALICE'S ROAD. WAUKEE, IOWA 50263PLUM DESIGN SERVICESDATE:DATE:DATE:ISSUE DATE:DATE:DATE:TELEPHONE 515 978 6260 FAX 515 978 6261THIS PAGE IS INTENDED TO BE PRINTED ON 24"X36" PAPER TO BE TO SCALEDATE: 1/8" = 1'-0"A10MezzaninePDS 4305Element 119Offices01-22-1902-07-1902-18-1904-24-1905-07-1907-23-19Scale: 1/8" = 1'-0"1MezzanineWINDOW SCHEDULEID QTY TYPEROUGH OPENINGSHEADERHEIGHT SPECIAL NOTESWIDTH HEIGHTH 2 3684-2 CA 6' - 0" 7' - 0" 8' - 0" FixedI 2 6024 F 5' - 0" 2' - 0" 8' - 0" PictureJ 5 7224 F 6' - 0" 2' - 0" PictureK 6 3684 F 3' - 0" 7' - 0" 8' - 0" PictureN 6 4848 F 4' - 0" 4' - 0" 8' - 0" PictureDOOR SCHEDULEID QTY NOMINAL SIZE DOOR TYPEROUGH OPENINGS FRAMEFIRERATINGPANELHARDWAREGROUPDESCRIPTIONLEVELWidth HeightAluminumInsulated MetalWoodRediframeThresholdAluminumInsul. MetalWoodThicknessPanel - TypeGlassD1351SF2 1 Storefront●●Full First FloorD1352RSA 1 3-0 x 6-8 3' - 2 1/4" 6' - 10 3/4" 0' - 1 3/4" Verify RO First FloorElementD4 1 12-0 x 14-0 Overhead Garage Door 12' - 3" 14' - 1 1/2"Overhead Garage Door First FloorRSA 1 3-0 x 6-8 3' - 2 1/4" 6' - 10 3/4" 0' - 1 3/4" Verify RO First FloorRWA 2 3-0 x 6-8 Interior Standard 3' - 2" 6' - 10 1/2"●●0' - 1 3/4" First FloorSF2 1 Storefront●●Full First FloorLaw FirmRSA 1 3-0 x 6-8 3' - 2 1/4" 6' - 10 3/4" 0' - 1 3/4" Verify RO First FloorSF1 1 Storefront●●Full First FloorOpen TenantD4 1 12-0 x 14-0 Overhead Garage Door 12' - 3" 14' - 1 1/2"Overhead Garage Door First FloorRSA 1 3-0 x 6-8 3' - 2 1/4" 6' - 10 3/4" 0' - 1 3/4" Verify RO First FloorStratfordD4 1 12-0 x 14-0 Overhead Garage Door 12' - 3" 14' - 1 1/2"Overhead Garage Door First FloorRSA 1 3-0 x 6-8 3' - 2 1/4" 6' - 10 3/4" 0' - 1 3/4" Verify RO First FloorRWA 1 3-0 x 6-8 Interior Standard 3' - 2" 6' - 10 1/2"●●0' - 1 3/4" First FloorSF2 1 Storefront●●Full First Floor ROOF SLOPEROOF SLOPEROOF SLOPEROOF SLOPEPLUM DESIGN SERVICE, INC. ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS. WE ARE NOT A LICENSED ARCHITECT OR ENGINEER. THESE PLANS ARE PROVIDED ON AN "AS IS" BASIS AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND/OR OWNER TO VERIFY AND CHECK ALL NOTES, DETAILS, ELEVATIONS, SECTIONS, AND FLOOR PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR AND/OR OWNER SHALL NOTIFY PLUM DESIGN SERVICE, INC. IMMEDIATELY IF ANY ERRORS OR OMISSION FOR POSSIBLE CORRECTION ARE IDENTIFIED PRIOR TO START OF CONSTRUCTION. NO WARRANTIES EXPRESS OR IMPLIED INCLUDING COMPLIANCE WITH THIS PLAN WITH APPLICABLE BUILDING CODES REQUIREMENTS ARE MADE.DATE:DATE:DATE:PROJECT ID:1100 SE ALICE'S ROAD. WAUKEE, IOWA 50263PLUM DESIGN SERVICESDATE:DATE:DATE:ISSUE DATE:DATE:DATE:TELEPHONE 515 978 6260 FAX 515 978 6261THIS PAGE IS INTENDED TO BE PRINTED ON 24"X36" PAPER TO BE TO SCALEDATE: 1/8" = 1'-0"A11Reflected CeilingPDS 4305Element 119Offices01-22-1902-07-1902-18-1904-24-1905-07-1907-23-19Scale: 1/8" = 1'-0"2Mezzanine Reflected Ceiling PlanScale: 1/8" = 1'-0"1First Floor Reflected Ceiling Plan First Floor0' - 0"First Floor0' - 0"T.O. Footing-4' - 0"T.O. Footing-4' - 0"Front Wall Hgt20' - 8 13/16"AABBRear Wall Hgt14' - 1 1/8"First Floor Wall Hgt9' - 1 1/8"Mezzanine10' - 1 3/4"80' - 0"11280' - 0"40' - 0"40' - 0"31' - 6"5 1/2"48' - 0 1/2"7' - 7 13/16"14' - 1 1/8"4' - 0"10' - 7 1/16"1' - 0 5/8"9' - 1 1/8"4' - 0"HEEL2' - 10"3' - 6"44' - 6 1/2"A145SimA143SimA142SimFirst Floor0' - 0"First Floor0' - 0"T.O. Footing-4' - 0"T.O. Footing-4' - 0"Front Wall Hgt20' - 8 13/16"AABBRear Wall Hgt14' - 1 1/8"First Floor Wall Hgt9' - 1 1/8"Mezzanine10' - 1 3/4"Tower Hgt28' - 8 13/16"8' - 0"20' - 8 13/16"4' - 0"10' - 7 1/16"1' - 0 5/8"9' - 1 1/8"80' - 0"48' - 0 1/2"5 1/2"31' - 6"80' - 0"40' - 0"40' - 0"44' - 6 1/2"3' - 6"31' - 11 1/2"7' - 7 13/16"11214' - 1 1/8"4' - 0"HEEL2' - 10"39' - 11 1/2"4' - 7"3' - 6"R @0' - 6 3/4"18A145A142A143PLUM DESIGN SERVICE, INC. ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS. WE ARE NOT A LICENSED ARCHITECT OR ENGINEER. THESE PLANS ARE PROVIDED ON AN "AS IS" BASIS AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND/OR OWNER TO VERIFY AND CHECK ALL NOTES, DETAILS, ELEVATIONS, SECTIONS, AND FLOOR PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR AND/OR OWNER SHALL NOTIFY PLUM DESIGN SERVICE, INC. IMMEDIATELY IF ANY ERRORS OR OMISSION FOR POSSIBLE CORRECTION ARE IDENTIFIED PRIOR TO START OF CONSTRUCTION. NO WARRANTIES EXPRESS OR IMPLIED INCLUDING COMPLIANCE WITH THIS PLAN WITH APPLICABLE BUILDING CODES REQUIREMENTS ARE MADE.DATE:DATE:DATE:PROJECT ID:1100 SE ALICE'S ROAD. WAUKEE, IOWA 50263PLUM DESIGN SERVICESDATE:DATE:DATE:ISSUE DATE:DATE:DATE:TELEPHONE 515 978 6260 FAX 515 978 6261THIS PAGE IS INTENDED TO BE PRINTED ON 24"X36" PAPER TO BE TO SCALEDATE: 1/4" = 1'-0"A12Building SectionsPDS 4305Element 119Offices01-22-1902-07-1902-18-1904-24-1905-07-1907-23-19Scale: 1/4" = 1'-0"2Mezzanine Section - 2Scale: 1/4" = 1'-0"1Mezzanine Section - 1 First Floor0' - 0"T.O. Footing-4' - 0"Front Wall Hgt20' - 8 13/16"5522113344First Floor Wall Hgt9' - 1 1/8"Mezzanine10' - 1 3/4"Tower Hgt28' - 8 13/16"4' - 0"20' - 8 13/16"8' - 0"9' - 1 1/8"1' - 0 5/8"10' - 7 1/16"R @0' - 6 3/4"18R @0' - 6 3/4"18190' - 0"45' - 4"45' - 4"45' - 4"54' - 0"190' - 0"45' - 4"45' - 4"45' - 4"54' - 0"First Floor0' - 0"First Floor0' - 0"T.O. Footing-4' - 0"T.O. Footing-4' - 0"Front Wall Hgt20' - 8 13/16"AABBRear Wall Hgt14' - 1 1/8"Tower Hgt28' - 8 13/16"A141A145SimA143Sim80' - 0"80' - 0"40' - 0"40' - 0"40' - 0"40' - 0"2' - 0"14' - 1 1/8"4' - 0"8' - 0"20' - 8 13/16"4' - 0"PLUM DESIGN SERVICE, INC. ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS. WE ARE NOT A LICENSED ARCHITECT OR ENGINEER. THESE PLANS ARE PROVIDED ON AN "AS IS" BASIS AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND/OR OWNER TO VERIFY AND CHECK ALL NOTES, DETAILS, ELEVATIONS, SECTIONS, AND FLOOR PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR AND/OR OWNER SHALL NOTIFY PLUM DESIGN SERVICE, INC. IMMEDIATELY IF ANY ERRORS OR OMISSION FOR POSSIBLE CORRECTION ARE IDENTIFIED PRIOR TO START OF CONSTRUCTION. NO WARRANTIES EXPRESS OR IMPLIED INCLUDING COMPLIANCE WITH THIS PLAN WITH APPLICABLE BUILDING CODES REQUIREMENTS ARE MADE.DATE:DATE:DATE:PROJECT ID:1100 SE ALICE'S ROAD. WAUKEE, IOWA 50263PLUM DESIGN SERVICESDATE:DATE:DATE:ISSUE DATE:DATE:DATE:TELEPHONE 515 978 6260 FAX 515 978 6261THIS PAGE IS INTENDED TO BE PRINTED ON 24"X36" PAPER TO BE TO SCALEDATE:As indicatedA13Building SectionsPDS 4305Element 119Offices01-22-1902-07-1902-18-1904-24-1905-07-1907-23-19Scale: 1/8" = 1'-0"1BUILDING SECTION - 1Scale: 1/4" = 1'-0"2BUILDING SECTION - 2 First Floor0' - 0"T.O. Footing-4' - 0"Front Wall Hgt20' - 8 13/16"BTower Hgt28' - 8 13/16"8' - 0"20' - 8 13/16"4' - 0"A144SimFront Wall Hgt20' - 8 13/16"BTower Hgt28' - 8 13/16"8' - 0"First Floor0' - 0"T.O. Footing-4' - 0"Front Wall Hgt20' - 8 13/16"BFirst Floor Wall Hgt9' - 1 1/8"Mezzanine10' - 1 3/4"10' - 7 1/16"1' - 0 5/8"9' - 1 1/8"4' - 0"A147First Floor0' - 0"T.O. Footing-4' - 0"ARear Wall Hgt14' - 1 1/8"14' - 1 1/8"4' - 0"A146Front Wall Hgt20' - 8 13/16"BARear Wall Hgt14' - 1 1/8"PLUM DESIGN SERVICE, INC. ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS. WE ARE NOT A LICENSED ARCHITECT OR ENGINEER. THESE PLANS ARE PROVIDED ON AN "AS IS" BASIS AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND/OR OWNER TO VERIFY AND CHECK ALL NOTES, DETAILS, ELEVATIONS, SECTIONS, AND FLOOR PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR AND/OR OWNER SHALL NOTIFY PLUM DESIGN SERVICE, INC. IMMEDIATELY IF ANY ERRORS OR OMISSION FOR POSSIBLE CORRECTION ARE IDENTIFIED PRIOR TO START OF CONSTRUCTION. NO WARRANTIES EXPRESS OR IMPLIED INCLUDING COMPLIANCE WITH THIS PLAN WITH APPLICABLE BUILDING CODES REQUIREMENTS ARE MADE.DATE:DATE:DATE:PROJECT ID:1100 SE ALICE'S ROAD. WAUKEE, IOWA 50263PLUM DESIGN SERVICESDATE:DATE:DATE:ISSUE DATE:DATE:DATE:TELEPHONE 515 978 6260 FAX 515 978 6261THIS PAGE IS INTENDED TO BE PRINTED ON 24"X36" PAPER TO BE TO SCALEDATE:As indicatedA14Building SectionsPDS 4305Element 119Offices01-22-1902-07-1902-18-1904-24-1905-07-1907-23-19Scale: 1/2" = 1'-0"1PARAPET WALL DETAILScale: 3/4" = 1'-0"4PARAPET DETAILScale: 1" = 1'-0"5STEEL BEAM DETAILScale: 1/2" = 1'-0"2WALL DETAIL @ MEZZANINEScale: 1/2" = 1'-0"3WALL DETAIL @ REAR WALLScale: 1" = 1'-0"7ROOF DETAIL @ FRONT WALLScale: 1" = 1'-0"6ROOF DETAIL @ REAR WALL GP GENERAL PARAMETERS GP1 STRUCTURAL DRAWINGS ARE A PORTION OF THE CONTRACT DOCUMENTS AND ARE INTENDED TO BE USED WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE REQUIREMENTS FROM THESE DRAWINGS INTO THEIR SHOP DRAWINGS AND WORK. GP2 VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO FABRICATION OF ANY ITEMS. GP3 DRAWINGS SHALL BE COORDINATED WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL OPENINGS, ELECTRICAL COMPONENTS, FLOOR DEPRESSIONS, ETC. NOT SHOWN ON DRAWINGS. COORDINATE LOCATION, SIZE AND REINFORCEMENT OF ALL OPENINGS WITH RESPECTIVE TRADES BEFORE FABRICATION. REPORT ANY DISCREPANCIES AND/OR INTERFERENCE PROBLEMS TO THE ARCHITECT AND STRUCTURAL ENGINEER OF RECORD. GP4 THESE GENERAL NOTES SUPPLEMENT THE PROJECT SPECIFICATIONS. REFER TO THE PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. NOTES AND DETAILS ON THE STRUCTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER THE GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE PROVIDED, CONSTRUCTION SHALL BE AS SHOWN FOR SIMILAR WORK. GP5 THE BUILDING IS NOT STRUCTURALLY STABLE UNTIL ALL CONNECTIONS, FRAMING, SHEAR WALLS, X-BRACING, AND EXTERIOR WALLS ARE COMPLETE AND HAVE ACHIEVED FINAL DESIGN STRENGTH. CONTRACTOR IS SOLELY RESPONSIBLE FOR MAINTAINING STRUCTURAL STABILITY OVERALL AND TO ALL PORTIONS OF THE BUILDING DURING DEMOLITION, ERECTION AND CONSTRUCTION. TEMPORARY GRAVITY AND LATERAL FORCE BRACING SYSTEMS THAT MAY BE REQUIRED WILL BE DESIGNED BY, AND AT THE EXPENSE OF, THE CONTRACTOR. STRUCTURAL DRAWINGS DO NOT NECESSARILY INDICATE ANY OR ALL REQUIRED TEMPORARY SUPPORT SYSTEMS. TEMPORARY BRACING SYSTEMS ARE NOT TO BE REMOVED UNTIL STRUCTURAL WORK IS COMPLETE OR CONTRACTOR DEEMS THE AREA UNDER CONSIDERATION TO BE STABLE. GP6 CONTRACTOR'S CONSTRUCTION AND/OR ERECTION SEQUENCES SHALL RECOGNIZE AND CONSIDER THE EFFECTS OF THERMAL MOVEMENTS OF STRUCTURAL ELEMENTS DURING THE CONSTRUCTION PERIOD. GP7 AS USED IN GENERAL NOTES AND THROUGHOUT STRUCTURAL DRAWINGS, THE TERM "CONTRACTOR" IS DEFINED TO INCLUDE ANY OR ALL OF THE FOLLOWING: GENERAL CONTRACTOR AND THEIR SUBCONTRACTORS, CONSTRUCTION MANAGER AND THEIR SUBCONTRACTORS, FABRICATORS, INSTALLERS, DELEGATED DESIGNERS/ENGINEERS AND ERECTORS. DP DESIGN PARAMETERS DP1 THE STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE ICC INTERNATIONAL BUILDING CODE, 2015 EDITION. DP2 UNIFORM LIVE LOADS: TYPICAL ROOF (GOVERNED BY SNOW)25 PSF+DRIFT DRIFT LOAD AS SHOWN ON PLAN MEZZANINE (OFFICE)50 PSF STAIRS AND OTHER EXITS 100 PSF DP3 CONCENTRATED LIVE LOADS: TYPICAL OFFICE (OVER 2.5 FT. x 2.5 FT.)2000 LB TYPICAL STAIRS (OVER 2 IN. x 2 IN.)300 LB DP4 SNOW DESIGN PARAMETERS: GROUND SNOW LOAD (Pg)30 PSF FLAT ROOF SNOW LOAD (Pf)25 PSF SNOW EXPOSURE FACTOR (C/E)1.0 SNOW LOAD IMPORTANCE FACTOR (I)1.0 SNOW LOAD THERMAL FACTOR (Ct)1.0 DP5 EARTHQUAKE DESIGN PARAMETERS: SEISMIC IMPORTANCE FACTOR (I/E)1.0 Ss 0.064g S1 0.045g SEISMIC SITE CLASS D Sds 0.068g Sd1 0.072g SHORT-PERIOD SITE COEFFICIENT (Fa)1.6 LONG-PERIOD SITE COEFFICIENT (Fv)2.4 SEISMIC DESIGN CATEGORY B SEISMIC-FORCE-RESISTING SYSTEM: LIGHT-FRAMED WALLS SHEATHED WITH WOOD STRUCTURAL PANELS RATED FOR SHEAR RESISTANCE OR STEEL SHEETS SEISMIC BASE SHEAR (V) N-S 5 k SEISMIC BASE SHEAR (V) E-W 5 k SEISMIC RESPONSE COEFFICIENT (Cs) 0.01 RESPONSE MODIFICATION FACTOR (R) 6.5 REDUNDANCY FACTOR (ρ) 1.0 SEISMIC ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE ANALYSIS DP6 WIND DESIGN PARAMETERS: BASIC WIND SPEED (V) (3 SECOND GUST)115 MPH RISK CATEGORY II WIND EXPOSURE CATEGORY C INTERNAL PRESSURE COEFFICIENT +/-.18 BASIC DESIGN PRESSURE @ ROOF 20 PSF (SERVICE) NET WIND UPLIFT @ ROOF 10 PSF (SERVICE) DP7 ALLOWABLE WALL DEFLECTIONS: EXTERIOR (CLADDING DESIGN) L/360 (BRICK VENEER DESIGN) L/600 ≤0.3" INTERIOR L/360 DP8 ALLOWABLE FRAMING DEFLECTIONS: ROOF LIVE LOAD L/360 ROOF TOTAL LOAD L/240 FLOOR LIVE LOAD L/360 FLOOR TOTAL LOAD L/240 DP9 ASSUMED FUTURE CONSTRUCTION: VERTICAL NONE HORIZONTAL NONE MINIMUM SHEAR CAPACITIES (SERVICE LOADS) SHAPE SHEAR CAPACITY W8 W10 W12 W14 W16 W18 16 KIPS 16 KIPS 28 KIPS 28 KIPS 41 KIPS 53 KIPS SHAPE SHEAR CAPACITY W24 W27 W30 W33 W36 72 KIPS 84 KIPS 94 KIPS 103 KIPS 115 KIPS W21 59 KIPS FP FOUNDATION PARAMETERS FP1 SIZE AND BOTTOM ELEVATIONS OF FOOTINGS HAVE BEEN ESTABLISHED BASED ON THE ASSUMED MINIMUM ALLOWABLE BEARING PRESSURE OF 1500 PSF AS SHOWN IN IBC TABLE 1806.2. AS EXCAVATION PROGRESSES, UNANTICIPATED SOIL CONDITIONS MAY REQUIRE CHANGES. CONTACT STRUCTURAL ENGINEER OF RECORD FOR EVALUATION OF THESE CHANGES. FP2 ALLOWABLE SOIL BEARING PRESSURE CONTINUOUS FOOTINGS.........................................1500 PSF SQUARE FOOTINGS.................................................1500 PSF FP3 MINIMUM FOOTING DEPTH FOR FROST PROTECTION (BELOW FINISHED GRADE)......................................42 IN. FP4 GEOTECHNICAL ENGINEER IS SOLE JUDGE OF THE SUITABILITY OF UNDERLYING MATERIAL TO SUPPORT FOUNDATIONS. BEARING MATERIAL SHALL BE APPROVED BY GEOTECHNICAL ENGINEER BEFORE FOUNDATION INSTALLATION. DO NOT PROCEED WITHOUT APPROVAL. FP5 PRIOR TO COMMENCING EARTHWORK, CONTRACTOR SHALL REVIEW AND BE FAMILIAR WITH ALL ASPECTS OF THE GEOTECHNICAL REPORT. CONTACT GEOTECHNICAL ENGINEER IF QUESTIONS OR DISCREPANCIES. COMMON NAIL SCHEDULE PENNYWEIGHT LENGTH (IN.) DIAMETER (IN.) 6d 2.00 0.113 8d 0.131 10d 0.148 16d 0.162 20d 0.192 2.50 3.00 3.50 4.00 8" o.c. WOOD FASTENER SCHEDULE NUMBER OR SPACING OF FASTENERS REQUIRED PER CONNECTION minimum nominal nail length (inches) x minimum nominal nail shank diameter (inches) Top or sole plate to stud / end nail Stud to top or sole plate / toe-nail Top plate laps and intersections / face nail each side of lap Sole plate to joist or blocking / face nail Sole plate to joist or blocking at braced wall panel /face nail (number per 16" joist space) Roof rafter to 2x ridge beam / toe-nail Roof rafter to 2x ridge beam / face nail through beam into end of rafter Ceiling joists laps over partitions / face nail Ceiling joist to parallel rafter / face nail Collar tie to rafter / face nail Jack rafter to hip / toe-nail Jack rafter to hip / face nail Roof rafter to plate / toe nail Corner studs / face nail Double studs / face nail Double top plate / face nail Diagonal bracing / face nail each stud N/AN/A12" o.c.12" o.c.8" o.c.16" o.c.16" o.c.16" o.c. 12" o.c. 16" o.c. 12" o.c. 12" o.c. 8" o.c. 8" o.c. 6" o.c. 8" o.c. 12" o.c.12" o.c. N/A N/A N/A N/A N/A - Fastener not applicable to connection 16" o.c. 12" o.c. 24" o.c. 2 3 3 4 N/A 4 4 8" o.c.8" o.c.6" o.c.8" o.c.8" o.c.8" o.c.16" o.c. 2 2 3 2 3 4 3 2 2 3 4 3 3 4 3 4 3 22 3 4 45 4 4 4 3 3 N/A 3 N/A 5 N/A N/A 5 N/A 4 N/A N/AN/A 2 3 3 3 3 4 4 N/A N/A N/AN/A44N/A3332 3 3 3 3 4 4 5 5 N/AN/A4433332 3 3 4 4 5 4 4 N/A N/A N/AN/A N/AN/A3 3 4 4 5 4 4 4464443 3 4 4 4 6 4 4 N/A N/A N/A65555543Ceiling joist to plate / toe-nail Built-up girders and beams /face nail at top and bot. staggered each side of each layer 24" o.c. (3 ea. end and splice) 24" o.c. (3 ea. end and splice) 24" o.c. (3 ea. end and splice) 24" o.c. (3 ea. end and splice) 16" o.c. (4 ea. end and splice) 16" o.c. (3 ea. end and splice) 16" o.c. (3 ea. end and splice) N/A N/A 3" o.c.6" o.c.4" o.c.6" o.c.6" o.c.6" o.c.6" o.c.6" o.c.Rim joist to top plate /toe-nail Bridging to joist /toe-nail each end N/A N/A N/A N/A 2 3 3 3 4 N/AN/A4434333 Blocking between joist or rafter to top plate / toe-nail Joist to sill or girder / toe-nail Ledger strip / face nail Joist to band joist / face nail N/AN/A4434333 3 4 4 4 6 4 4 N/A N/A N/AN/A66N/A5553 CONNECTION/LOCATION 3 1/2 x 0.162 3 x 0.148 3 1/4 x 0.131 3 x 0.131 2 1/2 x 0.131 3 1/4 x 0.120 3 x 0.120 2 3/8 x 0.113 2 x 0.113 8" o.c.8" o.c. 3 VERIFICATION AND INSPECTION FREQUENCY / TASK STEEL & DECKING 1. INSPECT REINFORCEMENT, INCLUDING PRESTRESSING TENDONS, & VERIFY PLACEMENT. 9. INSPECT FORMWORK FOR SHAPE, LOCATION & DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED. CONCRETE SOILS 1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY. 2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH & HAVE REACHED PROPER MATERIAL. 3. PERFORM CLASSIFICATION & TESTING OF COMPACTED FILL MATERIALS. 4. VERIFY USE OF PROPER MATERIALS, DENSITIES & LIFT THICKNESSES DURING PLACEMENT & COMPACTION OF COMPACTED FILL. 5. PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE & VERIFY THAT SITE HAS BEEN PREPARED PROPERLY. PROGRAM FOOTNOTES 1. THE ITEMS INDICATED ABOVE SHALL BE INSPECTED IN ACCORDANCE WITH CHAPTER 17 OF THE IBC BY A CERTIFIED SPECIAL INSPECTOR FROM AN ESTABLISHED TESTING AGENCY. FOR MATERIAL SAMPLING AND TESTING REQUIREMENTS, REFER TO THE PROJECT SPECIFICATIONS & THE SPECIFIC STRUCTURAL NOTES SECTIONS. THE TESTING AGENCY SHALL SEND COPIES OF ALL STRUCTURAL TESTING & INSPECTION REPORTS DIRECTLY TO THE ARCHITECT, STRUCTURAL ENGINEER, CONTRACTOR, & BUILDING OFFICIAL. ANY MATERIALS WHICH FAIL TO MEET THE PROJECT SPECIFICATIONS SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. SPECIAL INSPECTION TESTING REQUIREMENTS APPLY EQUALLY TO ALL BIDDER DESIGNED COMPONENTS. 2. CONT.-CONTINUOUS SPECIAL INSPECTION. SPECIAL INSPECTOR IS PRESENT WHEN & WHERE THE WORK TO BE INSPECTED IS BEING PERFORMED. (IBC SECTION 1702). 3. PERIODIC -PERIODIC SPECIAL INSPECTION. SPECIAL INSPECTOR IS INTERMITTENTLY PRESENT WHERE THE WORK TO BE INSPECTED HAS BEEN OR IS BEING PERFORMED. 4. OBSERVE -SPECIAL INSPECTOR SHALL OBSERVE THESE ITEMS ON A RANDOM BASIS. OPERATIONS NEED NOT BE DELAYED PENDING THESE INSPECTIONS (AISC 360 SECTION N5). 5. PERFORM -SPECIAL INSPECTOR SHALL PERFORM THESE TASKS FOR EACH JOINT, CONNECTION, ELEMENT OR MEMBER (AISC 360 SECTION N5). 6. SPECIAL INSPECTION IS NOT REQUIRED FOR WORK PERFORMED BY AN APPROVED FABRICATOR (IBC SECTION 1704.2.2). 7. ALL WELDS SHALL BE VISUALLY INSPECTED. 8. CJP WELDS SHALL BE TESTED ULTRASONICALLY OR BY SIMILAR APPROVED METHOD. 9. INSPECTION FOR PREFABRICATED CONSTRUCTION SHALL BE THE SAME AS IF THE MATERIAL USED IN THE CONSTRUCTION TOOK PLACE ON SITE. CONTINUOUS INSPECTION WILL NOT BE REQUIRED DURING PREFABRICATION IF THE APPROVED AGENCY CERTIFIES THE CONSTRUCTION AND FURNISHES EVIDENCE OF COMPLIANCE. 10. ALL ELEMENTS OF THE WOOD FRAMED LATERAL LOAD RESISTING SYSTEM SHALL BE VISUALLY INSPECTED. SP SPECIAL INSPECTION SP1 SPECIAL INSPECTION PROGRAM SHALL CONFORM TO CHAPTER 17 OF THE IBC. SP2 THE OWNER SHALL EMPLOY A SPECIAL INSPECTOR TO PERFORM THE REQUIRED TESTS AND SPECIAL INSPECTIONS WITH QUALIFICATIONS DESCRIBED PER IBC CHAPTER 17 AND THE PROJECT SPECIFICATIONS. SP3 SPECIAL INSPECTION REPORTS SHALL BE FURNISHED TO BUILDING OFFICIAL, OWNER, ARCHITECT, STRUCTURAL ENGINEER, AND CONTRACTOR. SP4 SPECIAL INSPECTOR SHALL SUBMIT A FINAL REPORT STATING THAT THE STRUCTURAL WORK WAS, TO THE BEST OF THE SPECIAL INSPECTOR'S KNOWLEDGE, PERFORMED IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS. SP5 SPECIAL INSPECTION PROGRAM: 2. INSPECTION TASKS PRIOR TO WELDING: A. WELDING PROCEDURE SPECIFICATIONS (WPS) AVAILABLE. B. MANUFACTURER'S CERTIFICATIONS FOR WELDING CONSUMABLES AVAILABLE. C. MATERIAL IDENTIFICATION (TYPE/GRADE). D. WELDER IDENTIFICATION SYSTEM. E. FIT-UP OF GROOVE WELDS (INCLUDING JOINT GEOMETRY): •JOINT PREPARATION •DIMS. (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL) •CLEANLINESS (CONDITION OF STEEL SURFACES) •TACKING (TACK WELD QUALITY & LOCATION) •BACKING TYPE & FIT (IF APPLICABLE) F. CONFIGURATION & FINISH OF ACCESS HOLES. G. FIT-UP OF FILLET WELDS: •DIMS. (ALIGNMENT, GAPS AT ROOT) •CLEANLINESS (CONDITION OF STEEL SURFACES) •TACKING (TACK WELD QUALITY & LOCATION) 3. INSPECTION TASKS DURING WELDING: B. USE OF QUALIFIED WELDERS. C. CONTROL & HANDLING OF WELDING CONSUMABLES: •EXPOSURE CONTROL •PACKAGING D. NO WELDING OVER CRACKED TACK WELDS. E. ENVIRONMENTAL CONDITIONS: •WIND SPEED WITHIN LIMITS •PRECIPITATION & TEMP. F. WPS FOLLOWED: •SETTINGS ON WELDING EQPT.•TRAVEL SPEED •SELECTED WELDING MATERIALS •PREHEAT APPLIED •SHIELDING GAS TYPE/FLOW RATE •PROPER POSITION (F, V, H, OH) •INTERPASS TEMP. MAINTAINED (MIN / MAX) G. WELDING TECHNIQUES: •INTERPASS & FINAL CLEANING •EACH PASS WITHIN PROFILE LIMITATIONS •EACH PASS MEETS QUALITY REQUIREMENTS 4. INSPECTION TASKS AFTER WELDING. A. WELDS CLEANED. B. SIZE, LENGTH, & LOCATION OF WELDS. C. WELDS MEET VISUAL ACCEPTANCE CRITERIA: •CRACK PROHIBITION •WELD SIZE •WELD / BASE-METAL FUSION •UNDERCUT •CRATER CROSS SECTION •POROSITY •WELD PROFILES E. ARC STRIKES. F. k-AREA. G. BACKING & WELD TABS REMOVED (IF REQ'D.). H. REPAIR ACTIVITIES. I. DOCUMENT ACCEPTANCE OR REJECTION OF WELDED JOINT OR MEMBER. 5. INSPECTION TASKS PRIOR TO BOLTING: A. MFR. CERTS. AVAILABLE FOR FASTENER MATERIALS. B. FASTENERS MARKED IN ACCORDANCE w/ ASTM RQMTS. C. PROPER FASTENERS SELECTED FOR THE JOINT DETAIL (GRADE, TYPE, BOLT LENGTH, EXCLUDED THREADS). D. PROPER BOLTING PROCEDURE SELECTED FOR JOINT DETAIL. E. CONNECTING ELEMENTS, INCLUDING THE APPROPRIATE FAYING SURFACE CONDITION & HOLE PREPARATION, IF SPECIFIED, MEET APPLICABLE RQMTS. F. PRE-INSTALLATION VERIFICATION TESTING BY INSTALLATION PERSONNEL OBSERVED & DOCUMENTED FOR FASTENER ASSEMBLIES & METHODS USED. G. PROPER STORAGE PROVIDED FOR BOLTS, NUTS, WASHERS & OTHER FASTENER COMPONENTS. 6. INSPECTION TASKS DURING BOLTING: A. FASTENER ASSEMBLIES, OF SUITABLE CONDITION, PLACED IN ALL HOLES & WASHERS (IF REQ'D) ARE POSITIONED AS REQ'D. B. JOINT BROUGHT TO THE SNUG-TIGHT CONDITION PRIOR TO THE PRETENSIONING OPERATION. C. FASTENER COMPONENT NOT TURNED BY THE WRENCH PREVENTED FROM ROTATING. D. FASTENERS ARE PRETENSIONED IN ACCORDANCE w/ THE RCSC SPECIFICATION, PROGRESSING SYSTEMATICALLY FROM THE MOST RIGID POINT TOWARD THE FREE EDGES. 7. INSPECTION TASKS AFTER BOLTING: A. DOCUMENT ACCEPTANCE OR REJECTION OF BOLTED CONNS. 2. INSPECT REINFORCING BAR WELDING: 3. INSPECT ANCHORS CAST IN CONCRETE. 5. VERIFY USE OF REQUIRED DESIGN MIX. 6. PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP & AIR CONTENT TESTS AND DETERMINE CONCRETE TEMPERATURE. 7. INSPECT CONCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES. 8. VERIFY MAINTENANCE OF SPECIFIED CURING TEMPERATURE & TECHNIQUES. PERFORM PERFORM OBSERVE OBSERVE OBSERVE OBSERVE OBSERVE OBSERVE OBSERVE OBSERVE OBSERVE OBSERVE OBSERVE OBSERVE OBSERVE OBSERVE OBSERVE OBSERVE OBSERVE OBSERVE OBSERVE OBSERVE OBSERVE OBSERVE PERFORM PERFORM PERFORM PERFORM PERFORM PERFORM PERFORM PERFORM PERFORM PERIODIC PERIODIC PERIODIC PERIODIC PERIODIC CONT. CONT. PERIODIC PERIODIC PERIODIC PERIODIC CONT. 1) COMPLETE & PARTIAL PENETRATION GROOVE WELDS. 2) MULTIPASS FILLET WELDS. 3) SINGLE-PASS FILLET WELDS > 5/16". 5) SINGLE-PASS FILLET WELDS ≤5/16". A. STRUCTURAL STEEL: 4) PLUG & SLOT WELDS. OBSERVE OBSERVE PERFORM PERFORM PERFORM PERFORM D. ULTRASONIC TESTING TO BE PERFORMED ON COMPLETE JOINT PENETRATION WELDS PER AWS D1.1-2010. PERFORM A. VERIFY WELDABILITY OF REINFORCING BARS OTHER THAN ASTM A706. B. INSPECT SINGLE-PASS FILLET WELDS, MAXIMUM 5/16". C. INSPECT ALL OTHER WELDS. PERIODIC PERIODIC CONT. 4. INSPECT ANCHORS POST-INSTALLED IN HARDENED CONCRETE MEMBERS: A. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR UPWARDLY INCLINED ORIENTATIONS TO RESIST SUSTAINED TENSION LOADS. CONT. B. MECHANICAL ANCHORS AND ADHESIVE ANCHORS NOT DEFINED IN 4.A.PERIODIC 1. VERIFY COMPLIANCE OF DECK & ALL DECK ACCESSORIES WITH CONSTRUCTION DOCUMENTS, INCLUDING PROFILES, PROPERTIES & THICKNESS. PERFORM CN CONCRETE NOTES CN1 CONCRETE WORK SHALL CONFORM TO CHAPTER 19 OF THE IBC. CN2 WHERE NEW CONCRETE IS PLACED AGAINST EXISTING CONCRETE, THE EXISTING CONCRETE SURFACE SHALL BE CLEANED AND ROUGHENED TO A MINIMUM OF 1/4" AMPLITUDE. CN3 ALL EXPOSED EDGES OF CONCRETE MEMBERS SHALL BE CHAMFERED 3/4" U.N.O. CN4 CONCRETE FORMWORK: CN4.1 SLEEVES, OPENINGS, CONDUIT, AND OTHER EMBEDDED ITEMS NOT SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE APPROVED BY THE STRUCTURAL ENGINEER PRIOR TO POURING CONCRETE. CONDUITS EMBEDDED IN SLABS SHALL NOT BE LARGER IN OUTSIDE DIMENSION THAN ONE THIRD OF THE THICKNESS OF THE SLAB AND SHALL NOT BE SPACED CLOSER THAN THREE DIAMETERS ON CENTER. CN4.2 VERIFY ALL BLOCK OUTS WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING REQUIREMENTS PRIOR TO POURING. CN5 CONCRETE REINFORCEMENT: CN5.1 DETAILING, FABRICATION, AND PLACEMENT OR REINFORCEMENT SHALL CONFORM TO ACI-315. CN5.2 ALL REINFORCEMENT TO BE ASTM A615 GRADE 60 U.N.O. WELDED WIRE FABRIC TO BE ASTM A185 WITH WIRE CONFORMING TO ASTM A82. REINFORCING STEEL SHALL BE SECURELY TIED IN PLACE USING #16 ANNEALED IRON WIRE. REINFORCEMENT SHALL BE CONTINUOUS THROUGH ALL CONSTRUCTION JOINTS, U.N.O. CN5.3 ALL CONTINUOUS REINFORCING SHALL BE SPLICED USING CLASS B TENSION SPLICES, U.N.O. CN5.4 BARS IN BEAMS AND SLABS SHALL BE SUPPORTED ON WELL-CURED CONCRETE BLOCKS OR APPROVED METAL CHAIRS, AS SPECIFIED BY THE CRSI MANUAL OF STANDARD PRACTICE, MSP-1. CN5.5 CONTINUE HORIZONTAL WALL BARS THROUGH PILASTERS, COLUMNS, INTERSECTING WALLS AND INTERSECTING FOUNDATIONS. REFER TO TYPICAL DETAILS FOR LAYOUT OF CORNER BARS AND BARS IN SMALL WALL SECTIONS. SLAB BARS SHALL BE HOOKED INTO WALLS OR HOOKED DOWELS SHALL BE PROVIDED TO MATCH SLAB REINFORCING. PROVIDE HOOKED DOWELS FROM FOOTINGS TO MATCH VERTICAL WALL REINFORCING. CN5.6 ADD TWO DIAGONAL #5 BARS, FOUR FEET LONG, CENTERED, AT EACH CORNER OF FOUNDATION OR SLAB OPENING, U.N.O. CN5.7 U.N.O., INSTALL WWF 1 1/2" FROM TOP OF ALL SLABS ON GRADE, TOPPING SLABS ON DECK, OR TOPPING SLABS ON PRECAST. LAP JOINTS TWO FULL MESHES BUT NOT LESS THAN 8". AT CONSTRUCTION JOINTS, LOCATE WWF AT MID DEPTH OF SLAB. CN6 COVERAGE FOR REINFORCEMENT: CN6.1 CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH .................3" CN6.2 CONCRETE EXPOSED TO EARTH AND WEATHER: #6 THRU #18 BARS ..................................2" #5 BAR, W31 OR D31 WIRE AND SMALLER ........................................1 1/2" CN6.3 CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: SLABS, WALLS, JOISTS: #14 AND # 18 ............................................1 1/2" #11 BAR AND SMALLER .........................3/4" BEAMS, COLUMNS: PRIMARY REINFORCEMENT, TIES, STIRRUPS, SPIRALS ......................1 1/2" CN7 CONCRETE COMPRESSIVE STRENGTHS SHALL BE VERIFIED BY STANDARD 28-DAY CYLINDER TESTS PER ASTM C39 AND SHALL BE AS FOLLOWS: FOOTINGS..............................................................f'c = 3,000 PSI WALLS/PIERS/COLUMNS.......................................f'c = 4,000 PSI SLABS ON GRADE ..................................................f'c = 4,000 PSI CN8 SPECIAL INSPECTOR SHALL BE NOTIFIED IF ANY WATER IS TO BE ADDED IN FIELD. CN9 CONCRETE FOUNDATIONS: CN9.1 ALL FOUNDATION EXCAVATIONS MUST BE REVIEWED AND APPROVED BY THE SOILS ENGINEER PRIOR TO PLACEMENT OF CONCRETE. CN9.2 ACCURATELY SET AND SECURELY SUPPORT REINFORCING, DOWELS AND ANCHOR BOLTS PRIOR TO PLACEMENT OF CONCRETE. WET- STICKING OR FLOATING OF REINFORCING,DOWELS AND ANCHOR RODS IS NOT ALLOWED. CN9.3 PROVIDE CONSTRUCTION JOINTS, INSERTS, SLEEVES, DOWELS, ANCHORS, ETC., AS SHOWN. ITEMS SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS AND ACCORDING TO USUAL ACCEPTED STANDARDS OF THE TRADE. ANCHOR RODS PER ASTM F1554 AS SHOWN. CN9.4 ALL FOUNDATION COLD JOINTS SHALL BE KEYED. CONTINUOUS REINFORCING SHALL EXTEND ONE DEVELOPMENT LENGTH PLUS 6". LOCATE FOUNDATION COLD JOINTS AT EXPANSION JOINTS IN MASONRY VENEER WHEN POSSIBLE. CN9.5 REINFORCING SHOWN ON DETAILS IS THE REQUIRED MINIMUM. AT CONTRACTOR'S OPTION AND EXPENSE, ADDITIONAL REINFORCING MAY BE PERMITTED TO ASSIST IN EASE OF CONSTRUCTABILITY ADDITIONAL REINFORCING MUST BE SUBMITTED FOR REVIEW ON SHOP DRAWINGS. CN10 PROVIDE MINIMUM 6000 PSI NON-SHRINK, NON-METALLIC GROUT UNDER COLUMN BASE PLATES. GROUT SHALL NOT CONTAIN GYPSUM. COLUMN BASES TO BE GROUTED BEFORE PLACEMENT OF CONCRETE TOPPING ON STEEL FORMS. CN11 MINIMUM 4" CONCRETE SLAB ON GRADE WITH WWF 6X6-W2.1 X W2.1, OVER VAPOR BARRIER, OVER A MINIMUM 6" COMPACTABLE, TRIMMABLE, GRANULAR FILL, TYP. U.N.O. ON DRAWINGS AND GEOTECHNICAL REPORT. CN12 PROVIDE SLAB CONTROL JOINTS AS FOLLOWS, U.N.O.: CN12.1 SLABS (ON GRID LINE WHERE PRACTICAL) AND: SLAB-ON-GRADE ................................. 10' ± 2' CN12.2 MAINTAIN A CONTROL JOINT ASPECT RATIO OF APPROXIMATELY 1:1. CN13 PROVIDE VERTICAL WALL JOINTS AS FOLLOWS, U.N.O.: CN13.1 WALLS TALLER THAN 12'.....................H (H = WALL HEIGHT) CN13.2 WALLS 8' -12'.......................................2*H CN13.3 WALLS SHORTER THAN 8'...................3*H CN13.4 PROVIDE WALL JOINT WITHIN 10' OF ALL CORNERS AND IN LINE WITH EDGES OF ALL WALL OPENINGS. CN13.5 MAXIMUM WALL JOINT SPACING SHALL NOT EXCEED 25 FEET. CN14 CONCRETE ACCESSORIES: CN14.1 U.N.O., EXPANSION BOLTS TO BE HILTI KWIK BOLT TZ OR APPROVED EQUIVALENT WITH EQUAL ICC TENSION AND SHEAR VALUES. EXPANSION ANCHORS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. DO NOT CUT REINFORCING IN NEW OR EXISTING CONCRETE DURING INSTALLATION. CN14.2 U.N.O., EPOXY ANCHORS TO BE HILTI HIT-RE 500 V3 OR APPROVED EQUIVALENT WITH EQUAL ICC TENSION AND SHEAR VALUES. EPOXY ANCHORS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. DO NOT CUT REINFORCING IN NEW OR EXISTING CONCRETE DURING INSTALLATION. CN15 PERMANENTLY EXPOSED EMBEDDED PLATES AND ANGLES TO BE HOT-DIP GALVANIZED AFTER FABRICATION, U.N.O. NO LOADS OR WELDS SHALL BE PLACED ON EMBEDDED PLATES OR ANGLES FOR A MINIMUM OF 7 DAYS AFTER CASTING. CN16 U.N.O. IN ARCHITECTURAL DRAWINGS, 2" RIGID EXTRUDED POLYSTYRENE PERIMETER INSULATION OR EQUAL TO BE INSTALLED ON INSIDE FACE OF FOUNDATION WALL/GRADE BEAM, EXTENDING DOWN FROM THE TOP OF FOUNDATION 42 INCHES, AND EXTENDING IN FROM THE EDGE OF FOUNDATION 24 INCHES BELOW SLAB. CN17 EPOXY REPAIR ADHESIVE SHALL CONFORM TO ASTM C881 AND SHALL BE A TWO- COMPONENT, LIQUID EPOXY WITH NON-SAG CONSISTENCY AND A LONG POT LIFE. THE EPOXY ADHESIVE SHALL BE SUITABLE FOR USE IN DRY OR DAMP CONDITIONS. MINIMUM SHEAR STRENGTH SHALL BE 5,000 PSI; MINIMUM TENSILE STRENGTH SHALL BE 4,000 PSI. HOLE SIZES AND INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH THE APPROVED ICC REQUIREMENTS. DO NOT CUT REINFORCING IN NEW OR EXISTING CONCRETE DURING PLACEMENT. CN18 COLD WEATHER PROTECTION CN18.1 DURING COLD WEATHER CONSTRUCTION, CONTRACTOR IS RESPONSIBLE FOR PROTECTING CURING CONCRETE PER THE RQMTS. OF ACI 306. CN18.2 DURING COLD WEATHER CONSTRUCTION, CONTRACTOR IS RESPONSIBLE FOR PROTECTING FOUNDATIONS THAT DO NOT EXTEND TO FROST DEPTH FROM HEAVING. AT CONTRACTOR'S OPTION, BOTTOM OF FOOTINGS MAY BE EXTENDED BEYOND THE FROST ZONE, IN LIEU OF SURFACE PROTECTION METHODS. NO ADD'L REINFORCING WILL BE REQ'D AT EXTENDED FOUNDATIONS. ALL MITIGATION WORK SHALL BE PART OF THE CONTRACTOR BID AND NOT COMPENSIBLE BY CHANGE ORDER. CN18.3 CONTRACTOR TO PROVIDE A FROST STOOP PER TYP. STOOP DETAIL @ ALL EXTERIOR DOORS, SEE ARCH. FOR DOOR LOCATIONS. SF STEEL FRAMING NOTES SF1 STEEL FRAMING WORK SHALL COMPLY WITH CHAPTER 22 OF THE IBC. SF2 STEEL FRAMING MATERIALS: SF2.1 W -SECTIONS ASTM A992 FY=50,000 PSI SF2.2 TUBULAR STEEL ASTM A500 GR B FY=46,000 PSI SF2.3 CHANNELS, ANGLES, BARS ASTM A36 FY=36,000 PSI SF2.4 PLATES (NOT LOCATED AT MOMENT CONNECTIONS) ASTM A36 FY=36,000 PSI SF2.5 PLATES (LOCATED AT MOMENT CONNECTIONS) ASTM A572 FY=50,000 PSI SF2.6 PIPES ASTM A53 GR B FY=35,000 PSI SF2.7 WELDING ELECTRODES E70XX SF3 STEEL ERECTION SHALL COMPLY WITH ALL OSHA, STATE, LOCAL, AND UNION REGULATIONS. IN ADDITION, AT THE END OF THE WORK DAY, ALL COLUMNS MUST BE FRAMED WITH BEAMS AND/OR GIRDERS IN TWO DIRECTIONS, OR ADEQUATELY GUYED OR BRACED IN BOTH DIRECTIONS. TEMPORARY GUYING/BRACING IS THE RESPONSIBILITY OF THE ERECTOR (DESIGN AND INSTALLATION). SF4 DESIGN, FABRICATION, AND ERECTION SHALL BE IN ACCORDANCE WITH THE AISC STEEL CONSTRUCTION MANUAL, AISC 360-16 INCLUDING COMMENTARY, AND THE AISC 303-16. SF5 ALL BOLTS FOR STEEL CONNECTIONS TO BE INSTALLED PER AISC 360 AND RCSC. SF5.1 ALL BOLTS TO BE ASTM A325-N U.N.O. SF5.2 ALL BOLTS SHALL BE INSTALLED SNUG-TIGHT U.N.O. SF5.3 ALL BOLTS IN BRACED FRAME CONNECTIONS TO BE PRETENSIONED U.N.O. SF6 WELDING SHALL CONFORM TO THE AWS CODES FOR ARC AND GAS WELDING IN BUILDING CONSTRUCTION. WELDING SHALL BE PERFORMED IN ACCORDANCE WITH A WELDED PROCEDURE SPECIFICATION (WPS) AS REQUIRED IN AWS D1.1 AND APPROVED BY THE STRUCTURAL ENGINEER. THE WPS VARIABLES SHALL BE WITHIN THE PARAMETERS ESTABLISHED BY THE FILLER-METAL MANUFACTURER. SF7 WELDS SHALL BE MADE USING E70XX ELECTRODES AND SHALL BE 3/16" MINIMUM, U.N.O. ALL WELDING FOR STRUCTURAL STEEL CONNECTIONS TO BE PERFORMED BY CERTIFIED WELDERS IN ACCORDANCE WITH AWS D1.1. SF8 FOR COMPLETE JOINT PENETRATION WELDS, WELDS SHALL BE MADE WITH FILLER METAL THAT HAS A MINIMUM CVN TOUGHNESS OF 20 FT-LBS AT 40° F. SF10 EXCEPT FOR STEEL THAT IS TO RECEIVE SPRAY-APPLIED FIREPROOFING (SEE ARCH. FOR LOCATIONS) OR GALVANIZATION, ALL STEEL BEAMS, COLUMNS, AND BRACING SHALL RECEIVE A SINGLE COAT OF SHOP APPLIED PRIMER. SF11 HOT-DIP GALVANIZE STEEL FOR THE FOLLOWING CONDITIONS: SF11.1 STEEL ELEMENTS PERMANENTLY EXPOSED TO WEATHER. SF11.2 STEEL ELEMENTS LOCATED IN UNCONDITIONED SPACES. SF11.3 STEEL ELEMENTS LOCATED OUTSIDE THE BUILDING THERMAL ENVELOPE. SF11.4 STEEL ELEMENTS LOCATED IN AREAS WITH HIGH HUMIDITY. SF11.5 ALL LINTEL ASSEMBLIES LOCATED IN EXTERIOR WALLS. SF11.6 WHERE PIECES REQUIRING GALVANIZATION ARE PART OF A LARGER ASSEMBLY, THE HOT-DIPPING PROCESS IS TO OCCUR AFTER COMPLETE FABRICATION OF THE ASSEMBLY. SF12 CONNECTIONS: SF12.1 WHERE CONNECTIONS ARE NOT SHOWN, THE CONNECTIONS SHALL BE DESIGNED AND DETAILED IN ACCORDANCE WITH THE REQUIREMENTS OF AISC SPECIFICATIONS FOR THE SHEAR CAPACITIES SHOWN BELOW: SF12.2 ANY CONNECTION REACTIONS EXCEEDING THE ABOVE MINIMUM SHEAR CAPACITIES ARE NOTED, IN KIPS, AT EITHER END OF THE MEMBER ON THE STRUCTURAL FRAMING PLANS. SF12.3 NO CONNECTION SHALL USE LESS THAN 2 ROWS OF BOLTS. SF12.4 ALL CONNECTIONS SHALL SATISFY THE REQUIREMENTS OF AISC AND OSHA. SF12.5 MOMENT CONNECTIONS ARE INDICATED ON DRAWINGS BY A DARKENED TRIANGLE ON THE END OF THE MEMBER TO BE MOMENT CONNECTED. IF THE BEAM END MOMENT IS NOT SHOWN, DEVELOP PLASTIC MOMENT CAPACITY OF MEMBER ABOUT MAJOR AXIS. WHERE POSSIBLE, USE SHEAR TAB WEB CONNECTION WITH MOMENT CONNECTION. SF12.7 AT STEEL CONNECTIONS WITH POST INSTALLED ANCHORS, THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT THE HOLE DIAMETERS COMPLY WITH THE MANUFACTURER'S RECOMMENDED DRILL BIT DIAMETER. WF WOOD FRAMING NOTES WF1 WOOD FRAMING WORK SHALL COMPLY WITH CHAPTER 23 OF THE IBC. WF2 THE QUALITY OF WOOD PRODUCTS AND FASTENERS, AND THE DESIGN OF OAD-SUPPORTING MEMBERS AND CONNECTIONS, SHALL CONFORM TO THE TANDARDS SPECIFIED IN THE AWC NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION AND ITS SUPPLEMENT DESIGN VALUES FOR WOOD CONSTRUCTION. WF3 COORDINATE WOOD NAILERS AND BLOCKING LOCATIONS WITH NEED AND REQUIREMENTS OF OTHER WORK INVOLVED. WF4 PROVIDE SOLID BLOCKING BETWEEN SAWN JOISTS AT ALL SUPPORTS AND AT MIDSPAN OF JOISTS EXCEEDING 8 FEET (8FEET ON-CENTER MAXIMUM SPACING FOR BLOCKING). WF5 GIRDER TRUSSES SHALL BEAR DIRECTLY OVER WALL STUDS. NUMBER OF STUDS SHALL MATCH THE NUMBER OF PLIES IN THE GIRDER TRUSS (MINIMUM OF TWO STUDS), U.N.O. WF6 CUTTING AND NOTCHING OF JOISTS AND STUDS SHALL CONFORM TO IBC SECTIONS 2308.8.2, 2308.9.10, AND 2308.10.4.2. WF7 SALVAGED LUMBER SHALL BE GRADED BY AN APPROVED GRADING AGENCY PRIOR TO USE AND SHALL MEET THE MINIMUM STRESSES SHOWN BELOW. WF8 WOOD FRAMING MATERIALS (MINIMUM DESIGN VALUES): WF8.1 SAWN LUMBER: WF8.1a LOAD-BEARING WALL STUDS DOUGLAS FIR-LARCH NO. 2 Fb = 900 PSI Ft = 575 PSI Fv = 180 PSI Fcp = 625 PSI F/c = 1,350 PSI E = 1,600,000 PSI WF8.1b FRAMING MEMBERS (BEAMS, JOISTS, ETC.) DOUGLAS FIR-LARCH NO. 2 Fb = 900 PSI Ft = 575 PSI Fv = 180 PSI Fcp = 625 PSI Fc = 1,350 PSI E = 1,600,000 PSI WF8.2 LAMINATED VENEER LUMBER (LVL): GRADE 1.9E Fb = 2,600 PSI Ft = 1,555 PSI Fv = 285 PSI Fcp = 750 PSI Fc = 2,510 PSI E = 1,900,000 PSI WF9 WOOD STRUCTURAL PANELS WF9.1 WOOD STRUCTURAL PANELS SHALL CONFORM TO THE REQUIREMENTS OF U.S. PRODUCT STANDARD PS1 FOR CONSTRUCTION AND INDUSTRIAL PLYWOOD, U.S. PRODUCT STANDARD PS2 PERFORMANCE STANDARD FOR WOOD-BASED STRUCTURAL-USE PANELS, OR APA PRP-108 PERFORMANCE STANDARDS. WF9.2 WOOD STRUCTURAL PANEL INSTALLATION SHALL BE IN CONFORMANCE WITH APA RECOMMENDATIONS. ALLOW 1/8" SPACING AT PANEL ENDS AND EDGES, UNLESS OTHERWISE RECOMMENDED BY THE PANEL MANUFACTURER. WF9.3 SHEAR WALL SHEATHING SHALL BE PLYWOOD OR OSB CONFORMING TO THE REQUIREMENTS FOR ITS TYPE SPECIFIED IN DOC PS1 OR PS2. SHEATHING SHALL BE APPLIED EITHER HORIZONTALLY OR VERTICALLY. SHEET SIZES SHALL BE 48"x96" UNLESS AT BOUNDARIES OR FRAMING CHANGES. WF9.4 WALL SHEATHING (SEE SHEAR WALL SCHEDULE): 15/32" CDX, APA RATED SHEATHING, 32/16 EXP. I OR 15/32" OSB, APA RATED SHEATHING, 32/16, EXP. I WF 9.5 ROOF SHEATHING (SEE DIAPHRAGM SCHEDULE): 5/8" OSB OR CDX, APA RATED SHEATHING, 40/20, EXP. I WF9.6 FLOOR SHEATHING (SEE DIAPHRAGM SCHEDULE): 3/4" OSB OR CDX, APA RATED SHEATHING, 48/24, EXP. I WF9.7 WOOD STRUCTURAL PANELS USED AS SUBFLOOR, ROOF, OR WALL SHEATHING SHALL BE FASTENED TO FRAMING MEMBERS AS FOLLOWS, U.N.O.: 10d COMMON NAILS SPACED AT 6" O.C. AT PANEL EDGES, 12" O.C. AT INTERMEDIATE SUPPORTS. -OR- 2 7/8" X .12" NAILS SPACED AT 4" O.C. AT PANEL EDGES, 8" O.C. AT INTERMEDIATE SUPPORTS. -OR- 2 3/4" 14 GAGE STAPLES SPACED AT 4" O.C. AT PANEL EDGES, 8" O.C. AT INTERMEDIATE SUPPORTS. WF9.8 ALL SHEAR WALL PANEL SHEATHING EDGES SHALL BE BLOCKED. EDGE NAILS SHALL BE AT LEAST 3/8" FROM EDGES AND PANEL ENDS. STAGGER NAILING ON EDGES. WF9.9 ALL ROOF SHEATHING AND SUB-FLOORING SHALL BE INSTALLED WITH FACE GRAIN PERPENDICULAR TO SUPPORTS, U.N.O. ROOF SHEATHING SHALL EITHER BE BLOCKED, TONGUE-AND-GROOVE, OR HAVE EDGES SUPPORTED BY PLYCLIPS. WHEN ROOF SHEATHING IS NAILED DIRECTLY TO BLOCKING, THE BLOCKING SHALL BE NAILED TO SUPPORT MEMBERS WITH A MINIMUM OF 16d NAILS AT 4" O.C. SUB- FLOORING SHEATHING SHALL BE UNBLOCKED, U.N.O. WF9.10 SUB-FLOOR PANELS SHALL BE TONGUE-AND-GROOVE AND FIELD GLUED TO THE FRAMING USING ADHESIVES MEETING APA SPECIFICATION AFG-01 OR ASTM D3498. PANELS SHALL ALSO BE GLUED AT THE TONGUE-AND-GROOVE JOINT. NAILING NOT SHOWN SHALL BE AS INDICATED IN IBC TABLE 2304.9.1. WF9.11 NAIL HEADS SHALL BE DRIVEN FLUSH WITH SHEATHING. DO NOT PENETRATE SURFACE PLY WITH NAIL HEADS. IF NAIL HEADS ARE NOT FLUSH, NOTIFY STRUCTURAL ENGINEER OF RECORD. WT WOOD TRUSS FRAMING NOTES WT1 WOOD FRAMING WORK SHALL COMPLY WITH CHAPTER 23 OF THE IBC. WT2 DESIGN OF PREMANUFACTURED WOOD ROOF TRUSSES SHALL BE BY THE CONTRACTOR. DESIGN SHALL CONFORM TO THE PROFILES SHOWN ON PLANS AND SECTIONS, THE REQUIREMENTS OF IBC SECTION 2303.4, AND THE RECOMMENDATIONS OF THE TRUSS PLATE INSTITUTE. WT3 TRUSS MANUFACTURER IS RESPONSIBLE FOR DESIGNING OF TRUSSES TO ACCOMMODATE ALL LONG TERM DEFLECTION (CREEP) IN TRUSSES. WT4 IN ADDITION TO SELF WEIGHT, LIVE AND LATERAL LOADS INDICATED IN STRUCTURAL NOTES, DEAD LOAD, ANY ADDITIONAL LOADING INDICATED ON PLANS AND DETAILS, SNOW DRIFT, AND A MAXIMUM NET UPLIFT INDICATED IN STRUCTURAL NOTES, TRUSSES SHALL BE DESIGNED TO RESIST THE FOLLOWING MINIMUM LOADS: WT4.1 ROOF TRUSS LOADS: TOP CHORD DEAD LOAD 10 PSF BOTTOM CHORD DEAD LOAD 10 PSF TOP CHORD LIVE LOAD 25 PSF + DRIFT BOTTOM CHORD LIVE LOAD 0 PSF WT5 STORE MATERIALS ABOVE GROUND ON LEVEL WOOD BLOCKING, COVER FROM RAIN, ALLOWING WATER TO DRAIN FROM ALL PARTS. WT6 TRUSS MANUFACTURER SHALL PROVIDE INSTRUCTIONS TO FIELD CONSTRUCTION PERSONNEL INDICATING PROPER ERECTION PROCEDURES OF TRUSSES AND INSTALLATION OF CONNECTIONS AND ANY BRIDGING AND BRACING. WT7 CONSTRUCTION (TEMPORARY) TRUSS BRACING SHALL BE DETERMINED, FURNISHED, AND INSTALLED BY THE TRUSS ERECTION SUBCONTRACTOR. CONSTRUCTION BRACING SHALL CONFORM TO THE REQUIREMENTS OF BCSI 1-03. WT8 PERMANENT LATERAL TRUSS BRACING REQUIRED FOR THE STRENGTH AND STABILITY OF TRUSS MEMBERS SHALL BE SPECIFIED BY TRUSS MANUFACTURER. WT9 ALL GIRDER TRUSSES THAT REQUIRE LAMINATING TWO OR MORE PLYS, MUST BE LAMINATED ACCORDING TO THE INSTRUCTIONS ON THE TRUSS DESIGN DRAWINGS BY THE TRUSS MANUFACTURER. WT10 CUTTING, DRILLING, OR ANY PROCEDURE THAT MAY DAMAGE THE TRUSS CHORDS OR WEBS IS NOT ALLOWED. REMOVAL OF TRUSS WEBS, EVEN TEMPORARILY, IS NOT ALLOWED. WT11 OVERLOADING A SINGLE OR GROUP OF TRUSSES WITH TOOLS, PLYWOOD, ROOFING, OR OTHER CONSTRUCTION MATERIALS IN NOT ALLOWED. ERECTING DAMAGED TRUSSES IS NOT ALLOWED. WT12 MAKING A FIELD REPAIR TO A DAMAGED TRUSS IS NOT ALLOWED WITHOUT APPROVAL FROM THE STRUCTURAL ENGINEER OF RECORD. WT13 U.N.O., CONTRACTOR TO PROVIDE FLOATING GYPSUM CORNER DETAILING AND FASTENING, PER THE GYPSUM ASSOCIATION'S SPECIFICATION FOR THE APPLICATION AND FINISHING OF GYPSUM PANEL PRODUCTS, GA-216. WJ PREMANUFACTURED WOOD JOIST FRAMING NOTES WJ1 WOOD FRAMING WORK SHALL COMPLY WITH CHAPTER 23 OF THE IBC. WJ2 PREMANUFACTURED WOOD JOISTS SHALL BE OF THE SIZE AND TYPE SHOWN ON THE DRAWINGS, MANUFACTURED BY TRUS-JOIST, OR AN APPROVED EQUIVALENT, CONFORMING TO APA EWS STANDARD PRI-400. ALTERNATES WILL BE CONSIDERED, PROVIDED THE ALTERNATE IS ICC APPROVED, IS COMPATIBLE WITH THE LOAD CAPACITY, DIMENSIONAL, AND FIRE RATING REQUIREMENTS OF THE PROJECT, AND HAS LVL FLANGES. WJ3 PROVIDE BRIDGING FOR PREMANUFACTURED WOOD JOISTS IN CONFORMANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ROOF JOISTS AND BRIDGING SHALL BE CAPABLE OF RESISTING A MAXIMUM NET UPLIFT AS SHOWN ON STRUCTURAL NOTES. WJ4 THE JOIST MANUFACTURER SHALL VISIT THE JOB SITE AS REQUIRED TO VERIFY PROPER INSTALLATION, IN WRITING. WJ5 JOISTS SHALL BE DESIGNED FOR THE LIVE LOADS INDICATED IN STRUCTURAL NOTES, DEAD LOAD, SELF WEIGHT, ANY ADDITIONALLOADING INDICATED ON PLANS AND DETAILS, SNOW DRIFT AND A MAXIMUM NET UPLIFT INDICATED IN STRUCTURAL NOTES. 12d 0.1483.25 SU SUBMITTALS SU1 GENERAL CONTRACTOR TO PROVIDE A SHOP DRAWING SUBMITTAL LOG ITEMIZING ALL PROPOSED SUBMITTALS FOR APPROVAL BY STRUCTURAL ENGINEER OF RECORD. SU2 ALL SHOP DRAWINGS SHALL BE CHECKED BY THE FABRICATOR AND APPROVED BY THE GENERAL CONTRACTOR PRIOR TO SUBMITTAL TO THE STRUCTURAL ENGINEER OF RECORD. SHOP DRAWING REVIEW BY ENGINEER IS LIMITED TO VERIFYING GENERAL CONFORMANCE TO THE CONTRACT DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR ANY CHANGES FROM THE CONTRACT DOCUMENTS, DIMENSIONAL ERRORS, COORDINATION ERRORS, OR OMISSIONS IN SHOP DRAWINGS. SU3 SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO FABRICATION AND CONSTRUCTION REGARDING ALL STRUCTURAL ITEMS, INCLUDING THE FOLLOWING: ● CONCRETE MIX DESIGNS (5 DAYS BEFORE POUR, MIN.) ● CONCRETE REINFORCEMENT ● STRUCTURAL STEEL ● PREMANUFACTURED WOOD JOISTS ● PREMANUFACTURED WOOD ROOF TRUSS SYSTEMS SU4 SHOP DRAWINGS SHALL INCLUDE CONNECTIONS AS WELL AS SIZE, SPACING, AND GRADE OF ALL MEMBERS. PLANS AND ANY DETAILING NECESSARY FOR DETERMINING FIT AND PLACEMENT SHALL ALSO BE INCLUDED. SU5 IF SHOP DRAWINGS DIFFER FROM OR ADD TO THE DESIGN OF THE STRUCTURAL DRAWINGS, THEY SHALL BEAR THE SEAL AND SIGNATURE OF AN ENGINEER REGISTERED IN THE APPROPRIATE STATE. ANY CHANGES TO THE STRUCTURAL DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT AND ARE SUBJECT TO REVIEW AND APPROVAL OF THE STRUCTURAL ENGINEER OF RECORD. SU6 DESIGN DRAWINGS, SHOP DRAWINGS, AND CALCULATIONS FOR THE DESIGN AND FABRICATION OF ITEMS THAT ARE DESIGNED BY THE CONTRACTOR, INCLUDING: ● STRUCTURAL STEEL CONNECTIONS ● PREFABRICATED WOOD JOISTS ● PREMANUFACTURED WOOD ROOF TRUSS SYSTEMS SHALL BEAR THE SEAL AND SIGNATURE OF AN ENGINEER REGISTERED IN THE APPROPRIATE STATE AND SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO FABRICATION AND CONSTRUCTION. CALCULATIONS SHALL BE INCLUDED FOR ALL CONNECTIONS TO THE STRUCTURE, CONSIDERING LOCALIZED EFFECTS ON STRUCTURAL ELEMENTS INDUCED BY THE CONNECTION LOADS. SU7 ITEMS THAT ARE DESIGNED BY THE CONTRACTOR SHALL BE DESIGNED TO RESIST THE LIVE LOADS INDICATED IN STRUCTURAL NOTES, DEAD LOAD, SELF WEIGHT, ANY ADDITIONAL LOADING INDICATED ON PLANS AND DETAILS, SNOW DRIFT, AND A NET WIND UPLIFT. SU8 ITEMS THAT ARE DESIGNED BY THE CONTRACTOR SHALL INCLUDE ANY RELEVANT TECHNICAL LITERATURE FROM MANUFACTURER. ALSO PROVIDE A CERTIFICATION FROM THE MANUFACTURER SHOWING THE PRODUCT IS IN COMPLIANCE WITH ALL APPLICABLE CODES AND STANDARDS. SU9 THE CONTRACTOR SHALL COORDINATE SEISMIC RESTRAINTS OF MECHANICAL, PLUMBING, AND ELECTRICAL EQUIPMENT, MACHINERY, AND ASSOCIATED PIPING WITH THE STRUCTURE. ANY CONNECTIONS TO STRUCTURE SHALL CONFORM TO ASCE 7, CHAPTER 13 AND SHALL BE DESIGNED BY AN ENGINEER REGISTERED IN THE APPROPRIATE STATE, AND SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO FABRICATION. SU10 FIELD ENGINEERED DETAILS DEVELOPED BY THE CONTRACTOR THAT DIFFER FROM OR ADD TO THE STRUCTURAL DRAWINGS SHALL BEAR THE SEAL AND SIGNATURE OF AN ENGINEER REGISTERED IN THE APPROPRIATE STATE AND SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO CONSTRUCTION. WF WOOD FRAMING NOTES WF10 NAILS AND STAPLES SHALL CONFORM TO THE REQUIREMENTS OF ASTM F1667. FASTENER TYPES AND SPACINGS SHALL BE AS INDICATED IN IBC TABLE 2304.9.1 OR ESR-1539, U.N.O. WF11 ALL FRAMING NAILS SHALL BE OF THE SIZE AND NUMBER INDICATED IN THE DRAWINGS AND CONFORM TO ASTM F1667 AND ESR-1539. NAILS SHALL BE IDENTIFIED BY LABELS (ATTACHED TO THEIR CONTAINERS) THAT SHOW THE MANUFACTURER'S NAME, NES REPORT NUMBER, NAIL SHANK DIAMETER, AND LENGTH. THIS INFORMATION ALSO SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER OF RECORD PRIOR TO FRAMING. NAILING NOT SHOWN SHALL BE AS INDICATED IN IBC TABLE 2304.9.1 OR ESR-1539. NAILS USED FOR FRAMING AND SHEATHING CONNECTIONS SHALL HAVE MIN. DIMENSIONS INDICATED IN THE TABLE BELOW: WF12 BOLTS AND LAG SCREWS SHALL CONFORM TO ANSI/ASME STANDARD B18.2.1. BOLT HOLES SHALL BE A MINIMUM OF 1/32" AND NO MORE THAN 1/16" LARGER THAN THE BOLT DIAMETER. ALL BOLTS AND LAG SCREWS SHALL BE INSTALLED WITH STANDARD CUT WASHERS. ALL A307 BOLTS SHALL HAVE CUT THREADS. WF13 METAL FRAMING CONNECTORS SHALL BE MANUFACTURED BY SIMPSON STRONG-TIE CO. ALL SPECIFIED FASTENERS MUST BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. BEFORE SUBSTITUTING ANOTHER BRAND, CONFIRM LOAD CAPACITY BASED ON RELIABLE PUBLISHED TESTING DATA OR CALCULATIONS. THE ENGINEER OF RECORD SHALL EVALUATE AND GIVE WRITTEN APPROVAL FOR SUBSTITUTION PRIOR TO INSTALLATION. HANGERS NOT SHOWN SHALL BE SIMPSON U-TYPE OR B-TYPE OF SIZE RECOMMENDED FOR THE MEMBER. WF14 ALL INTERIOR METAL FRAMING CONNECTORS SHALL RECEIVE G90 ZINC COATING, UNO. ALL METAL FRAMING CONNECTORS AND FASTENERS INSTALLED IN EXTERIOR CONDITIONS SHALL RECEIVE G185 (SIMPSON ZMAX) COATING OR APPROVED EQUIVALENT. ALL METAL FRAMING CONNECTORS AND FASTENERS SHALL BE COMPATIBLE WITH THE APPLIED WOOD TREATMENT. I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PROFESSIONAL SUPERVISION AND THAT I AM A DULY REGISTERED PROFESSIONAL ENGINEER IN THE STATE OF IOWA THIS NOTICE COVERS DWGS: S -SERIES SHEETS SIGNATURE: NAME: DATE: MY REGISTRATION EXPIRES IN IOWA: 12/31/19 ERIK RAKER, P.E. PLUM DESIGN SERVICE, INC. ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS. WE ARE NOT A LICENSED ARCHITECT OR ENGINEER. THESE PLANS ARE PROVIDED ON AN "AS IS" BASIS AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND/OR OWNER TO VERIFY AND CHECK ALL NOTES, DETAILS, ELEVATIONS, SECTIONS, AND FLOOR PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR AND/OR OWNER SHALL NOTIFY PLUM DESIGN SERVICE, INC. IMMEDIATELY IF ANY ERRORS OR OMISSION FOR POSSIBLE CORRECTION ARE IDENTIFIED PRIOR TO START OF CONSTRUCTION. NO WARRANTIES EXPRESS OR IMPLIED INCLUDING COMPLIANCE WITH THIS PLAN WITH APPLICABLE BUILDING CODES REQUIREMENTS ARE MADE. DATE: DATE: DATE: PROJECT ID: 1100 SE ALICE'S ROAD. WAUKEE, IOWA 50263 PLUM DESIGN SERVICES DATE: DATE: DATE: ISSUE DATE: DATE: DATE: TELEPHONE 515 978 6260 FAX 515 978 6261 THIS PAGE IS INTENDED TO BE PRINTED ON 24"X36" PAPER TO BE TO SCALE DATE:NOT FOR CONSTRUCTIONAs indicated S-001 STRUCTURAL NOTES RRE19164Element 119OfficesWaukee, IowaIssue Date F1 F1 F1F1 F2 F2 F1F1F1 F3F3F3 F2 F1 F1 F1F1 F2 F2 F1F1F1 F3F3F3 F2 FOUNDATION SYMBOL KEY T/ WALL/ STEEL T/ FOOTING JOIST BEARING T/ BRICK LEDGE ELEV. STEP 1 2 3 4 TOP OF 4" SLAB EL. = [0'-0"] WWF6x6-W2.1xW2.1 S-201 S-201 S-201 S-201 1 2 3 4 5 A A.5 B 4.5 5' - 0"12 S-201 12 S-201 12 S-201 12 S-201 190' - 0" 45' - 4"45' - 4"45' - 4"54' - 0" 19' - 0"26' - 4"19' - 0"26' - 4"22' - 8"22' - 8"26' - 11"27' - 1"80' - 0"40' - 0"40' - 0"5' - 0"3.52.51.5 5' - 0"2' - 0"0' - 0"-3' - 2"11 S-201 11 S-201 11 S-201 11 S-201 5' - 0"11 S-201 S-201 5 TYP. 11 S-201 11 S-201 5' - 0"5' - 0"5' - 0"5' - 0"12 S-201 9' - 6"5' - 1"4' - 5"9' - 5"5' - 1"4' - 6" 12 S-201 12 S-201 12 S-201 7' - 11 1/2"5' - 1"9' - 7 1/2"23' - 2" 3' - 9"3' - 11" 23' - 2" 8 S-201 13 S-201 13 S-201 13 S-201 HSS5X5X3/8BP1HSS5X5X3/8BP1HSS5X5X3/8BP1HSS5X5X3/8BP1HSS5X5X3/8BP1HSS6X4X1/4P1, BP2HSS5X5X3/8BP1HSS5X5X3/8BP1HSS6X4X1/4P1, BP214 S-201 14 S-201 14 S-201 14 S-201 14 S-201 1' - 2" 5' - 0"20' - 2"20' - 2"2' - 6"2' - 6"20' - 2"24' - 6" 2' - 5"2' - 7" 24' - 6" 1' - 2" 5' - 0"20' - 2" 15 S-201 15 S-201 W2W4 W1 W1W1WALL TYPE1 2 -0' - 8"-0' - 8"-0' - 8"-0' - 8" -0' - 8"-0' - 8" -0' - 8" 1' - 6"2' - 0"1' - 6"2' - 0"2' - 0"2' - 0"2' - 0" TYP. S-201 9 -0' - 8"-0' - 8"-3' - 2" 1 WALL TYPEW3WALL TYPEWALL TYPEW4W31' - 0"1' - 0"10' - 4"4' - 9 1/2"4' - 8"4' - 8"HSS3X3X1/4BP31' - 0"HSS3X3X1/4BP3HSS3X3X1/4BP3INDICATES SHEAR WALL HOLD DOWNS SEE SHEAR WALL SCHEDULE SIM. 1 SIM. WOOD SHEAR WALL SCHEDULE STUD SIZE 2x MARK 1 15/32" OSB -EXTERIOR BLOCKED 10d NAILS AT ALL PANEL EDGES, TOP AND BOTTOM PLATES, & BLOCKING, U.N.O. 10d NAILS @ 12" O.C. MAX. IN THE FIELD (ALL PANEL EDGES TO BE BLOCKED WITH 2x OR WIDER FRAMING, U.N.O.) NAILS SHALL BE 3/8" FROM PANEL EDGE 10d @ 6" O.C. EDGES (1)-1/2"Ø SIMPSON TITEN HD ANCHOR @ 48" O.C. (4" EMBED.) HOLD DOWN @ EA. END OF WALL (LOCATIONS SHOWN AS ON PLAN) (NO HOLD DOWN REQUIRED @ SIM.) HILTI SIMPSON SET-XP w/ THREADED ROD SEE DETAIL SIMPSON HDQ8-SDS3 w/ (20)-SDS1/4x3 SCREWS w/ 7/8" Ø THREADED ROD (10 1/2" EMBED.) w/ (3)-2x POST NOTES: 1) SEE ARCH. DRAWINGS FOR NON-STRUCTURAL COMPONENTS (I.E. GYP. BOARD, RESILIENT CHANNELS, ETC.). 2) SEE DETAIL FOR TYPICAL BUILT-UP 2x FRAMING SCHEME. 3) SEE DETAIL FOR TYPICAL WOOD SHEAR WALL ASSEMBLY. 2x 2 15/32" OSB -EXTERIOR BLOCKED 10d @ 4" O.C. EDGES (1)-1/2"Ø SIMPSON TITEN HD ANCHOR @ 32" O.C. (4" EMBED.) SIMPSON HDQ8-SDS3 w/ (20)-SDS1/4x3 SCREWS w/ 7/8" Ø THREADED ROD (10 1/2" EMBED.) w/ (3)-2x POST SHEATHING TYPE BLOCKED OR UNBLOCKED SILL PLATE CONNECTION @ SILL /6 S-401 /1 S-401 /5 S-401 FOOTING SCHEDULE 4'-0" x 4'-0" x 1'-2"(4)-#5 E.W. BOTTOM MARK DIMENSIONS DETAILS NOTES F1 5'-0" x 5'-0" x 1'-2"(5)-#5 E.W. BOTTOMF2 7'-0" x 7'-0" x 1'-4"(7)-#5 E.W. BOTTOMF3 9'-0" x 5'-0" x 1'-2"SHORT: (9)-#5 E.W. BOTTOM LONG: (5)-#5 E.W. BOTTOMF5 4'-0" x 4'-0" x 3'-6"F4 (4)-#6 E.W. TOP & BOTTOM --- --- --- --- --- PIER SCHEDULE 16" x 16" MARK SIZE P1 (4)-#6 VERT. BARS #3 TIES @ 12" O.C. REINFORCEMENT WALL SCHEDULE MARK WALL SIZE NOTES 1.55E TIMBERSTRAND LSL @ 16" O.C. W1 W2 MATERIAL WOOD 1 3/4"x7 1/4" DFL-#2 @ 16" O.C.WOOD 2x6 1.55E TIMBERSTRAND LSL @ 16" O.C.W3 WOOD (2) 1 3/4"x5 1/2" DFL-#2 @ 12" O.C.W4 WOOD 2x6 PLUM DESIGN SERVICE, INC. ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS. WE ARE NOT A LICENSED ARCHITECT OR ENGINEER. THESE PLANS ARE PROVIDED ON AN "AS IS" BASIS AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND/OR OWNER TO VERIFY AND CHECK ALL NOTES, DETAILS, ELEVATIONS, SECTIONS, AND FLOOR PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR AND/OR OWNER SHALL NOTIFY PLUM DESIGN SERVICE, INC. IMMEDIATELY IF ANY ERRORS OR OMISSION FOR POSSIBLE CORRECTION ARE IDENTIFIED PRIOR TO START OF CONSTRUCTION. NO WARRANTIES EXPRESS OR IMPLIED INCLUDING COMPLIANCE WITH THIS PLAN WITH APPLICABLE BUILDING CODES REQUIREMENTS ARE MADE. DATE: DATE: DATE: PROJECT ID: 1100 SE ALICE'S ROAD. WAUKEE, IOWA 50263 PLUM DESIGN SERVICES DATE: DATE: DATE: ISSUE DATE: DATE: DATE: TELEPHONE 515 978 6260 FAX 515 978 6261 THIS PAGE IS INTENDED TO BE PRINTED ON 24"X36" PAPER TO BE TO SCALE DATE:NOT FOR CONSTRUCTIONAs indicated S-101 FOUNDATION PLAN RRE19164Element 119OfficesWaukee, IowaIssue Date PLAN NOTES: 1. SEE SHEET S-201 FOR TYPICAL FOUNDATION / SLAB DETAILS 2. PX -INDICATES CONCRETE PIER. SEE PIER SCHEDULE FOR INFORMATION. T/ PIER = -0'-8" U.N.O. 3. FX -INDICATES CONCRETE FOOTING. SEE FOOTING SCHEDULE FOR INFORMATION NORTH 1/8" = 1'-0"A FOUNDATION PLAN CORNER BARS: MATCH SIZE & SPACING OF HORIZONTAL BARS FOR EACH LAYER OF REINFORCING STANDARD HOOK ALTERNATE ENDS HORIZONTAL BARS: SEE WALL & FOUNDATION SECTIONS FOR REQ'D SIZE & SPACING TYPICAL CLASS B LAP EXTEND INTERIOR HOOKS TO EXTERIOR FACE OF WALL, TYP. TYPICAL CLASS B LAP NOTES: 1. SEE FDN. PLAN FOR SLAB THICKNESS & REINFORCING 2. SEE GENERAL NOTE CN12 FOR JOINT LOCATIONS WWF, SEE PLAN COMPACTED GRANULAR FILL SEE GEOTECHNICAL REPORT 6" MIN. COMPACTED SUBGRADE (95%, MIN) SEE GEOTECHNICAL REPORT VAPOR BARRIER SEE ARCH. SLAB ON GRADE, SEE PLAN NOTES: 1. SEE FDN. PLAN FOR SLAB THICKNESS & REINFORCING 2. SEE GENERAL NOTE CN12 FOR JOINT LOCATIONS 1/8" TOOLED RADIUS EDGE COMPACTED GRANULAR FILL SEE GEOTECHNICAL REPORT 6" MIN. COMPACTED SUBGRADE (95%, MIN) SEE GEOTECHNICAL REPORT WWF, SEE PLAN 1/2"Ø x 1' -4" SMOOTH BAR w/ ONE END GREASED @ 16" O.C. LOCATED @ MID-HEIGHT OF SLAB & PERPENDICULAR TO JOINT VAPOR BARRIER SEE ARCH. SLAB ON GRADE, SEE PLAN NOTES: 1. SEE FDN. PLAN FOR SLAB THICKNESS & REINFORCING 2. SEE GENERAL NOTE CN12 FOR JOINT LOCATIONS SAWCUT JOINT WITHIN 12 HOURS OF POUR, SEE PLAN FOR LOCATIONS. DEPTH OF JOINT TO BE THE SMALLER OF 1/4 THE SLAB THICKNESS OR 2". 6" MIN. COMPACTED SUBGRADE (95%, MIN) SEE GEOTECHNICAL REPORT WWF, SEE PLAN VAPOR BARRIER SEE ARCH. SLAB ON GRADE SEE PLAN COMPACTED GRANULAR FILL SEE GEOTECHNICAL REPORT DOUBLE NUTS W/ AR1: 1/4" x 2" PLATE WASHERS COLUMN BASEPLATE SEE BASEPLATE DETAILS NON-SHRINK GROUT AR1 -3/4"Ø ASTM F1554 (36KSI) ANCHOR ROD DOUBLE NUTS 1/4"6" MIN.CONCRETE FOOTING/PIER2"3"9" AR1NOTE: 1. WET-SETTING/FLOATING OF ANCHOR RODS IS NOT ALLOWED. ACCURATELY SET AND SECURELY SUPPORT ANCHOR RODS DURING PLACEMENT OF CONCRETE. STEEL COLUMN SEE SCHEDULE VERTICAL BARS SEE PIER DETAILS FOR SIZE & SPACING #3 TIES FOOTING SEE PLAN FOOTING REINFORCEMENT SEE SCHEDULE FOR SIZE & SPACING SEE PLAN T/ FOOTING SEE PLAN T/ PIER 2" 2" 2" 2" NON-SHRINK GROUT 12" O.C.10 S-201 1' - 0"WALL BEYOND CONT. BARS THROUGH FOOTINGS & PIERS 3 1/4" CURB BEYOND VERTICAL BARS w/ STD. HOOKS SEE PIER SCHEDULE FOR SIZE AND QTY. #3 TIES, SEE FOR SPACING WALL REINF. NOT SHOWN. SEE WALL SECTIONS FOR SIZE & SPACING EQ EQ WALL CONFIGURATION VARIES, SEE PLAN /9 S-201 SEE SCHEDULEBASEPLATE OUTLINE 4 3/4" 8" 3 1/4" #4 x 4'-0" CENTERED IN SLAB @ 4 SIDES OF COLUMN EXPANSION MATERIAL AROUND COLUMN PERIMETER, SET 1/4" BELOW TOP OF SLAB ELEVATION CONSTRUCTION OR CONTROL JOINT, TYPICAL 3" CLEAR TYP.HSS COLUMN SEE PLAN BASE PLATE HOLE Ø PER AISC TABLE 14-2 & AISC DESIGN GUIDE 1 TABLE 2.3cEQ.EQ.cbSEE SCHEDULESEE SCHEDULE a c EQ.EQ. c 1/4 COLUMN SECTION t a b ANCHORS NOTES: 1. FOR COLUMN WALL THICKNESSES LESS THAN THAT SHOWN IN THE SCHEDULE, DEFAULT TO NEAREST TABULATED WALL THICKNESS. 2. SEE DETAIL FOR ANCHOR ROD SETTING INFORMATION. 3. SEE STRUCTURAL NOTES FOR BASE PLATE MATERIAL REQUIREMENTS. 4. FOR RECTANGULAR BASE PLATES, ALIGN LONG SIDE PARALLEL TO FOUNDATION WALL U.N.O. 5. WET-SETTING/FLOATING OF ANCHOR RODS IS NOT ALLOWED. ACCURATELY SET AND SECURELY SUPPORT ANCHOR RODS DURING PLACEMENT OF CONCRETE. STEEL COLUMN, SEE PLAN 3/4"6"12" HSS5X5 3/4"11"11"(4) -AR1 HSS6X4 (4) -AR1 c 1 1/2" 1 1/2" /6 S-201 BP2 BP1 MARK 3/4"6"9"HSS3X3 (4) 3/4"Ø x 3 3/4" SIMPSON TITEN HD w/ 3" EMBED1 1/2"BP3 STEEL COLUMN SEE PLAN EXPANSION MATERIAL ENCASE COLUMN IN CONCRETE COLUMN FOOTING SEE PLAN SEE ANCHOR ROD SETTING DETAILS FOR INFORMATION SEE PLAN T/ FOOTING SEE PLAN T/ SLAB NON-SHRINK GROUT SLAB ON GRADE SEE PLAN SEE BASE PLATE DETAIL FOR INFORMATION SEE PLAN T/ SLAB #5 DOWEL @ 1'-6" w/ STD. HOOK EA. FACE SLAB ON GRADE SEE PLAN (2) #5 CONT. THIN BRICK VENEER SEE ARCH. SEE PLAN RIGID INSULATION SEE ARCH 1' - 0"2x (TREATED) SILL PLATE w/ 1/2"ø SIMPSON TITEN HD ANCHOR SEE SHEAR WALL SCHEDULE FOR SPACING & EMBEDMENT EXTERIOR SHEATHING #3 @ 3'-0" O.C. (4) #5 CONT., (2T+2B) SEE PLAN T/ FOOTING EQ. 8" EQ. 1/2" JOINT 3" 2x WOOD FRAMING, SEE SCHEDULE SEE PLAN T/ SLAB RIGID INSULATION SEE ARCH. FRAMING BEYOND SEE PLAN SLAB ON GRADE SEE PLAN 8"5"SLOPE #4 @ 9" O.C. EACH WAY 1'-6" 1'-6" 4" VOID FORM SEE FROST WALL DETAIL FOR REINF. INFO. NOT SHOWN #4 DOWELS @ 24" O.C. (2) #5 CONT., 1T+1B 1' - 0"TSEE PLAN T/ FOOTING SEE PLAN T/ WALL SEE PLAN 5" 8" 5" 1' - 6" SLAB ON GRADE SEE PLAN SEE PLAN T/ SLAB 2x WOOD FRAMING, SEE SCHEDULE (2) #5 CONT. #5 @ 18" O.C. 2x SILL PLATE, SEE SCHEDULE FOR FASTENING 1' - 0"SEE PLAN SHEATHING, TYP. SEE ARCH. SEE PLAN T/ SLAB #5 DOWEL @ 1'-6" w/ STD. HOOK EA. FACE SLAB ON GRADE SEE PLAN (2) #5 CONT. THIN BRICK VENEER SEE ARCH. 2' - 0" RIGID INSULATION SEE ARCH 1' - 0"2x (TREATED) SILL PLATE w/ 1/2"ø SIMPSON TITEN HD ANCHOR SEE SHEAR WALL SCHEDULE FOR SPACING & EMBEDMENT EXTERIOR SHEATHING #3 @ 3'-0" O.C. (4) #5 CONT., (2T+2B) SEE PLAN T/ FOOTING EQ. 8" EQ. 1/2" JOINT 3" 2x WOOD FRAMING, SEE SCHEDULE SLAB ON GRADE, SEE PLAN SEE PLAN T/ SLAB STAIRS, SEE ARCH TREATED 2x6 NAILER w/ (1) 1/2"ø HILTI KWIK BOLT 3 w/ 4" EMBEDMENT CENTERED BETWEEN STRINGERS 2' - 0"1' - 0"STAIR STRINGER (2) #5 CONT. #3 @ 18" O.C.MIN.7 1/4"PLUM DESIGN SERVICE, INC. ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS. WE ARE NOT A LICENSED ARCHITECT OR ENGINEER. THESE PLANS ARE PROVIDED ON AN "AS IS" BASIS AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND/OR OWNER TO VERIFY AND CHECK ALL NOTES, DETAILS, ELEVATIONS, SECTIONS, AND FLOOR PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR AND/OR OWNER SHALL NOTIFY PLUM DESIGN SERVICE, INC. IMMEDIATELY IF ANY ERRORS OR OMISSION FOR POSSIBLE CORRECTION ARE IDENTIFIED PRIOR TO START OF CONSTRUCTION. NO WARRANTIES EXPRESS OR IMPLIED INCLUDING COMPLIANCE WITH THIS PLAN WITH APPLICABLE BUILDING CODES REQUIREMENTS ARE MADE. DATE: DATE: DATE: PROJECT ID: 1100 SE ALICE'S ROAD. WAUKEE, IOWA 50263 PLUM DESIGN SERVICES DATE: DATE: DATE: ISSUE DATE: DATE: DATE: TELEPHONE 515 978 6260 FAX 515 978 6261 THIS PAGE IS INTENDED TO BE PRINTED ON 24"X36" PAPER TO BE TO SCALE DATE:NOT FOR CONSTRUCTIONAs indicated S-201 FOUNDATION DETAILS RRE19164Element 119OfficesWaukee, IowaIssue Date 1/2" = 1'-0"5 TYP. REINFORCING @ CORNERS 1 1/2" = 1'-0"1 TYP. SLAB ON GRADE 1 1/2" = 1'-0"2 TYP. SLAB ON GRADE CONSTRUCTION JOINT 1 1/2" = 1'-0"3 TYP. SLAB ON GRADE CONTROL JOINT 3" = 1'-0"6 TYP. ANCHOR ROD SETTING DETAIL 3/4" = 1'-0"9 TYP. CONCRETE PIER 3/4" = 1'-0"10 TYP. CONCRETE PIER DETAIL 1/2" = 1'-0"4 TYP. SLAB ISOLATION JOINT @ HSS COLUMN 1" = 1'-0"7 HSS COLUMN BASE PLATE SCHEDULE 3/4" = 1'-0"8 TYP. STEEL COLUMN @ INTERIOR FOOTING1 3/4" = 1'-0"11 PERIMETER FOOTING 1/2" = 1'-0"12 FOUNDATION @ STOOP 3/4" = 1'-0"13 TYP. THICKENED SLAB @ WOOD BEARING/SHEAR WALL 3/4" = 1'-0"14 PERIMETER FOOTING 3/4" = 1'-0"15 STAIRS @ SLAB H1 H1 H1 H1 H1 H2 H2 H2 H1 H1 H1 H1 H1 H1 H1 1 2 3 4 5 A A.5 B 4.5 190' - 0" 45' - 4"45' - 4"45' - 4"54' - 0" 19' - 0"26' - 4"19' - 0"26' - 4"22' - 8"22' - 8"26' - 11"27' - 1"80' - 0"40' - 0"40' - 0"W21X44 19' - 0" W21X44 19' - 0" W21X44 19' - 0" W21X44 19' - 0" W21X44 19' - 0" 3.5 W21X44 19' - 0" 2.51.5 W21X44 19' - 0" W21X44 19' - 0" 9 S-401 PRE-ENGINEERED WOOD TRUSSES @ 24" O.C., U.N.O. PRE-ENGINEERED WOOD TRUSSES @ 24" O.C., U.N.O. 10 S-401 12 S-401 D-2 D-2 11 S-401 15 S-401 1 S-402 1 S-402 1 S-402 1 S-402 11 S-401 15 S-401 12 S-401W4 WALL TYPEWALL TYPEW3WALL TYPEWALL TYPEW4W3HSS12X2X1/4 9'-10 1/2" TYP. MITRE & FIELD WELD CORNER GRIND SMOOTH, TYP. HSS12X2X1/4 9'-10 1/2" TYP. HSS12X2X1/4 9'-10 1/2" TYP. MITRE & FIELD WELD CORNER GRIND SMOOTH, TYP. HSS12X2X1/4 12'-3 1/4" TYP. MITRE & FIELD WELD CORNER GRIND SMOOTH, TYP. HSS12X2X1/4 9'-10 1/2" TYP. MITRE & FIELD WELD CORNER GRIND SMOOTH, TYP. HSS12X2X1/4 9'-10 1/2" TYP. HSS12X2X1/4 9'-10 1/2" TYP. TYP. 2 S-402 W2 W1 1 S-402 1 S-402 1 S-402 SIM.SIM. SIM. SIM. SIM. WOOD SHEAR WALL SCHEDULE STUD SIZE 2x MARK 1 15/32" OSB -EXTERIOR BLOCKED 10d NAILS AT ALL PANEL EDGES, TOP AND BOTTOM PLATES, & BLOCKING, U.N.O. 10d NAILS @ 12" O.C. MAX. IN THE FIELD (ALL PANEL EDGES TO BE BLOCKED WITH 2x OR WIDER FRAMING, U.N.O.) NAILS SHALL BE 3/8" FROM PANEL EDGE 10d @ 6" O.C. EDGES (1)-1/2"Ø SIMPSON TITEN HD ANCHOR @ 48" O.C. (4" EMBED.) HOLD DOWN @ EA. END OF WALL (LOCATIONS SHOWN AS ON PLAN) (NO HOLD DOWN REQUIRED @ SIM.) HILTI SIMPSON SET-XP w/ THREADED ROD SEE DETAIL SIMPSON HDQ8-SDS3 w/ (20)-SDS1/4x3 SCREWS w/ 7/8" Ø THREADED ROD (10 1/2" EMBED.) w/ (3)-2x POST NOTES: 1) SEE ARCH. DRAWINGS FOR NON-STRUCTURAL COMPONENTS (I.E. GYP. BOARD, RESILIENT CHANNELS, ETC.). 2) SEE DETAIL FOR TYPICAL BUILT-UP 2x FRAMING SCHEME. 3) SEE DETAIL FOR TYPICAL WOOD SHEAR WALL ASSEMBLY. 2x 2 15/32" OSB -EXTERIOR BLOCKED 10d @ 4" O.C. EDGES (1)-1/2"Ø SIMPSON TITEN HD ANCHOR @ 32" O.C. (4" EMBED.) SIMPSON HDQ8-SDS3 w/ (20)-SDS1/4x3 SCREWS w/ 7/8" Ø THREADED ROD (10 1/2" EMBED.) w/ (3)-2x POST SHEATHING TYPE BLOCKED OR UNBLOCKED SILL PLATE CONNECTION @ SILL /6 S-401 /1 S-401 /5 S-401 H1 WOOD HEADER SCHEDULE (3)-2x12 w/ (2)-2x6 FULL HEIGHT STUDS + (2)-2x6 JACK STUDS @ EA. JAMB MARK SIZE NOTES H2 (4)-1 3/4" x 14" w/ (2)-2x6 FULL HEIGHT STUDS + (2)-2x6 JACK STUDS @ EA. JAMB /3 S-401 /3 S-401 WOOD SHEATHING SCHEDULE 3/4" T&G OSB SHEATHING SEE WF GENERAL STRUCTURAL NOTES D-1 AT FLOORS MARK TYPE DETAILS NOTES 5/8" OSB SHEATHING SEE WF GENERAL STRUCTURAL NOTES AT ROOFD-2 1 A.5 B 1.5 11 7/8" LP20 PLUS @ 16" O.C.7 S-401 13 S-40113 S-401 SIM.D-1CANOPY SEE SHEET S-301 1 3/4"x14" LVL STRINGER @ 12" O.C. w/ 1 3/4"x7 1/4" LVL SISTER (2) 2x12 HEADER 2x12 @ 16" O.C. ..2 A.5 B 2.5 11 7/8" TJI 230 @ 16" O.C.7 S-401 8 S-401 13 S-401 1 3/4"x14" LVL STRINGER @ 12" O.C. w/ 1 3/4"x7 1/4" LVL SISTER 14 S-401 D-1JOIST BEARING EL. = 9'-1 1/8" CANOPY SEE SHEET S-301 1 S-402 (2) 2x12 HEADER 2x12 @ 16" O.C. ..PLUM DESIGN SERVICE, INC. ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS. WE ARE NOT A LICENSED ARCHITECT OR ENGINEER. THESE PLANS ARE PROVIDED ON AN "AS IS" BASIS AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND/OR OWNER TO VERIFY AND CHECK ALL NOTES, DETAILS, ELEVATIONS, SECTIONS, AND FLOOR PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR AND/OR OWNER SHALL NOTIFY PLUM DESIGN SERVICE, INC. IMMEDIATELY IF ANY ERRORS OR OMISSION FOR POSSIBLE CORRECTION ARE IDENTIFIED PRIOR TO START OF CONSTRUCTION. NO WARRANTIES EXPRESS OR IMPLIED INCLUDING COMPLIANCE WITH THIS PLAN WITH APPLICABLE BUILDING CODES REQUIREMENTS ARE MADE. DATE: DATE: DATE: PROJECT ID: 1100 SE ALICE'S ROAD. WAUKEE, IOWA 50263 PLUM DESIGN SERVICES DATE: DATE: DATE: ISSUE DATE: DATE: DATE: TELEPHONE 515 978 6260 FAX 515 978 6261 THIS PAGE IS INTENDED TO BE PRINTED ON 24"X36" PAPER TO BE TO SCALE DATE:NOT FOR CONSTRUCTIONAs indicated S-301 FRAMING PLAN RRE19164Element 119OfficesWaukee, IowaIssue Date PLAN NOTES: 1. T/ STEEL = XX'-XX" U.N.O. 2. SEE SHEET S-401 FOR TYPICAL FRAMING DETAILS. 3.SEE SCHEDULE ON S-001 FOR MINIMUM WOOD FASTENER REQUIREMENTS. 4.DESIGN OF TRUSSES & BRACING FOR 10 PSF NET UPLIFT. 5.ROOF TRUSS LAYOUT FOR BIDDING PURPOSES ONLY. TRUSS DETAILER TO PROVIDE FINAL LAYOUT. NORTH 1/8" = 1'-0"A ROOF FRAMING PLAN NORTH 1/8" = 1'-0"B MEZZANINE A FRAMING PLAN NORTH 1/8" = 1'-0"C MEZZANINE B FRAMING PLAN 12d @ 8" O.C. STAGGERED EA. SIDE (2) -2x STUDS (MAY BE USED IN LIEU OF (1) -3x STUD) (3) -2x STUDS8" 8" 1 1/2" MIN. 1 1/2" MIN. 2X4 STUD ELEVATION (2) ROWS 12d @ 8" O.C. EA. SIDE 1 1/2" MIN. 1 1/2" MIN. 2X6 OR LARGER STUD ELEVATION (4) -2x STUDS8"8"8"8"DIST.2 1/2" ENDDIST.2 1/2" END8"8"2x FRAMING, TYP. SEE SCHEDULE SIMPSON LSTA18 ON INTERIOR FACE CENTERED @ SPLICE SPLICE MIN. SPLICE 4' - 0" 10d NAILS @ 12" O.C. SPLICE SIMPSON LSTA18 ON INTERIOR FACE CENTERED @ SPLICE SEE PLAN T/ PLATE DOUBLE 2x TOP PLATE PLY 2x HEADER WITH 1/2" PLYWOOD SPACERS TO MATCH 2x STUD WIDTH FULL HEIGHT 2x4 OR 2x6 STUDS SEE HEADER SCHEDULE FASTEN HEADER TO STUDS WITH (6) -10d COMMON NAILS @ EACH END JACK STUDS -FACE NAIL DOUBLE STUDS WITH 16d COMMON NAILS @ 24" O.C. SEE HEADER SCHEDULE 2x FRAMING @ 16" O.C. (TYP.) 16d COMMON NAILS @ 16" O.C. @ TOP AND BOTTOM (STAGGERED) w/(3) 16d NAILS @ EACH END NOTE:KING AND JACK STUDS SHALL BE CONTINUOUS FOR ALL FLOORS BELOW HEADER. SEE ARCH. B/ HEADER 2x DOUBLE TOP PLATE. SEE ARCH. NUMBER OF STUDS TO MATCH STUDS @ POSTS AND JAMBS ABOVE DIAPHRAGM BOUNDARY STRUCTURAL PANEL SHEATHING ONE SIDE ONLY SEE PLAN FOR THICKNESS AND GRADE 10d COMMON NAILS SPACED @ MAXIMUM 6" O.C. @ DIAPHRAGM BOUNDARY AND SUPPORTED EDGES 10d COMMON NAILS SPACED @ 12" O.C. MAX @ INTERMEDIATE FRAMING MEMBERS THIS PANEL JOINT NOT CONTINUOUS CONTINUOUS PANEL JOINT ROOF TRUSSES, TYP. PANEL EDGE NAILING SEE SCHEDULE FOR PATTERN NAILS NO LESS THAN 3/8" FROM PANEL EDGES 2x STUDS FRAMING, SEE SCHEDULE (TYPICAL) w/ (2) -8d TOE NAILS @ EACH END WOOD STRUCTURAL PANEL SHEATHING SEE SCHEDULE HOLD DOWNS -SEE PLAN FOR LOCATION AND SEE SCHEDULE FOR TYPE N-PLY 2x STUDS AT SHEAR WALL ENDS, SEE SHEAR WALL SCHEDULE FOR NUMBER OF PLYS PANEL BLOCKING AS REQ'D, SEE SCHEDULE INTERMEDIATE FIELD NAILS @ 12" O.C., TYPICAL S-401 6 2x STUDS FRAMING w/ (2)-10d T&B, TYP. SEE SCHEDULE TREATED 2x SILL PLATE THREADED ROD w/ EPOXY ADHESIVE, SEE SCHEDULE FOR SIZE AND EMBEDMENT SCREWS PER SIMPSON'S SPECIFICATIONS N-PLY 2x STUDS AT SHEAR WALL ENDS FACE NAIL WITH 10d COMMON NAILS SPACED AT 12" O.C. WITH 6" VERTICAL STAGGER EA. SIDE EA. PLY SEE SHEAR WALL SCHEDULE FOR NUMBER OF PLYS SIMPSON HOLDOWN, SEE PLAN FOR LOCATION SEE SCHEDULE FOR SIZE SEE PLAN T/SLAB FLOOR JOIST, SEE PLAN DOUBLE TOP PLATE WOOD WALL, SEE SCHEDULE FLOOR SHEATHING SEE PLAN SEE GENERAL NOTE FOR NAILING SEE PLAN JOIST BEARING 2x4 LEDGER FOR CEILING ATTACHMENT SHEATHING, SEE ARCH. FLOOR JOIST, SEE PLAN DOUBLE TOP PLATE WOOD WALL, SEE SCHEDULE FLOOR SHEATHING SEE PLAN SEE GENERAL NOTE FOR NAILING 1 1/4" RIM BOARD SHEATHING, SEE ARCH. SQUASH BLOCK 10d NAIL INTO EA. FLANGE SEE PLAN JOIST BEARING RAILING, SEE ARCH. 1/4 1/4 WF BEAM SEE PLAN HSS COLUMN SEE PLAN SEE PLAN T/ STEEL 3/8" MIN. SHEAR TAB w/ MIN. 3/4"Ø A325N BOLTS 1/2" MAX. 3" 1 1/2"TYP.1 1/2"TYP.3"1/4" CAP PLATE w/ SEAL WELD ALL AROUND SEE ARCH SEE PLAN TRUSS BEARING PRE-ENGINEERED WOOD ROOF TRUSSES BY TRUSS SUPPLIER, SEE PLAN TRUSS UPLIFT CALCULATION IS THE RESPONSIBILITY OF TRUSS SUPPLIER. 2x BLOCKING SHALL BE ADDED @ EVERY OTHER TRUSS SPACE -NAIL TO TOP PLATE AND SHEATHING, FIT TIGHT BETWEEN EA. TRUSS OSB ROOF SHEATHING, SEE PLAN TRUSS TIE DOWN: SEE NOTE BELOW TYPICAL TRUSS = SIMPSON H2.5A NOTE:TIE DOWNS ARE FOR ESTIMATING PURPOSES ONLY. FINAL DESIGN SHALL BE DETERMINED AFTER TRUSS UPLIFT CALCULATIONS ARE PROVIDED BY TRUSS SUPPLIER. SHEATHING, SEE SCHEDULE 2x WOOD FRAMING, SEE SCHEDULE DOUBLE 2x TOP PLATE SEE ARCH SEE PLAN TRUSS BEARING PRE-ENGINEERED WOOD ROOF TRUSSES BY TRUSS SUPPLIER, SEE PLAN TRUSS UPLIFT CALCULATION IS THE RESPONSIBILITY OF TRUSS SUPPLIER. 2x BLOCKING SHALL BE ADDED @ EVERY OTHER TRUSS SPACE -NAIL TO TOP PLATE AND SHEATHING, FIT TIGHT BETWEEN EA. TRUSS OSB ROOF SHEATHING, SEE PLAN TRUSS TIE DOWN: SEE NOTE BELOW TYPICAL TRUSS = SIMPSON H2.5A NOTE:TIE DOWNS ARE FOR ESTIMATING PURPOSES ONLY. FINAL DESIGN SHALL BE DETERMINED AFTER TRUSS UPLIFT CALCULATIONS ARE PROVIDED BY TRUSS SUPPLIER. SHEATHING, SEE SCHEDULE 2x WOOD FRAMING, SEE SCHEDULE DOUBLE 2x TOP PLATE FLOOR JOIST, SEE PLAN DOUBLE TOP PLATE WOOD WALL, SEE SCHEDULE FLOOR SHEATHING SEE PLAN SEE GENERAL NOTE FOR NAILING 1 1/4" RIM BOARD SHEATHING, SEE ARCH. OSB @ SIM. SQUASH BLOCK 10d NAIL INTO EA. FLANGE SEE PLAN JOIST BEARING TREADS, SEE ARCH SIMPSON LSSU210-2 HANGER STRINGERS, SEE PLAN, DO NOT OVERCUT MIN.7 1/4"FASTEN SISTER JOIST TO EA. STRINGER w/ (2)-10d NAILS @ 16" O.C. SEE ARCH. T/ FINISHED FLOOR NOTES: 1) SEE ARCH FOR NON- STRUCTURAL COMPONENTS WOOD BEAM, SEE PLAN SIMPSON HUC212-2 HANGER BEYOND SIMPSON LUS210 HANGER BEYOND SEE ARCH SEE PLAN TRUSS BEARING PRE-ENGINEERED WOOD ROOF TRUSSES BY TRUSS SUPPLIER, SEE PLAN TRUSS UPLIFT CALCULATION IS THE RESPONSIBILITY OF TRUSS SUPPLIER. 2x BLOCKING SHALL BE ADDED @ EVERY OTHER TRUSS SPACE -NAIL TO TOP PLATE AND SHEATHING, FIT TIGHT BETWEEN EA. TRUSS PARAPET SHALL BE INTEGRAL w/ ROOF TRUSS Wd= 43 PSF TRUSS TIE DOWN: SEE NOTE BELOW TYPICAL TRUSS = SIMPSON H2.5A NOTE:TIE DOWNS ARE FOR ESTIMATING PURPOSES ONLY. FINAL DESIGN SHALL BE DETERMINED AFTER TRUSS UPLIFT CALCULATIONS ARE PROVIDED BY TRUSS SUPPLIER. SHEATHING, SEE SCHEDULE 2x WOOD FRAMING, SEE SCHEDULE DOUBLE 2x TOP PLATE SEE ARCH. T/ WALL OSB ROOF SHEATHING, SEE PLAN 2x4 BLOCKING @ 4'-0" O.C. SEE ARCH. SISTER 2x4 TO TRUSS. ATTACH w/ 12d NAILS @ 6" O.C. STAGGERED DOUBLE 2x TOP PLATE WOOD FRAMING, SEE PLAN PRE-ENGINEERED ROOF TRUSS BY TRUSS SUPPLIER ROOF SHEATHING, SEE PLAN 4-10d NAILS @ E.E. LU26 HANGER @ E.E., TYP. 2x4 BRACE @ 3'-0" O.C. 2x12 CONT. LEDGER 3-SDS SCREWS INTO EACH STUD (SDS25300) 2x6 FOR EACH DIAGONAL BRACE WOOD SHEATHING, SEE SCHEDULE 2x6 BLOCKING @ ROOF LINE PLUM DESIGN SERVICE, INC. ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS. WE ARE NOT A LICENSED ARCHITECT OR ENGINEER. THESE PLANS ARE PROVIDED ON AN "AS IS" BASIS AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND/OR OWNER TO VERIFY AND CHECK ALL NOTES, DETAILS, ELEVATIONS, SECTIONS, AND FLOOR PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR AND/OR OWNER SHALL NOTIFY PLUM DESIGN SERVICE, INC. IMMEDIATELY IF ANY ERRORS OR OMISSION FOR POSSIBLE CORRECTION ARE IDENTIFIED PRIOR TO START OF CONSTRUCTION. NO WARRANTIES EXPRESS OR IMPLIED INCLUDING COMPLIANCE WITH THIS PLAN WITH APPLICABLE BUILDING CODES REQUIREMENTS ARE MADE. DATE: DATE: DATE: PROJECT ID: 1100 SE ALICE'S ROAD. WAUKEE, IOWA 50263 PLUM DESIGN SERVICES DATE: DATE: DATE: ISSUE DATE: DATE: DATE: TELEPHONE 515 978 6260 FAX 515 978 6261 THIS PAGE IS INTENDED TO BE PRINTED ON 24"X36" PAPER TO BE TO SCALE DATE:NOT FOR CONSTRUCTIONAs indicated S-401 FRAMING DETAILS RRE19164Element 119OfficesWaukee, IowaIssue Date 3/4" = 1'-0"1 BUILT UP 2x FRAMING 1/2" = 1'-0"2 TOP PLATE SPLICE 3/4" = 1'-0"3 TYPICAL HEADER DETAIL 1/4" = 1'-0"4 WOOD ROOF DIAPHRAGM NAILING N.T.S.5 TYP. WOOD SHEAR WALL ELEVATION 3/4" = 1'-0"6 SHEAR WALL HOLDOWN TO CONCRETE 1" = 1'-0"7 FLOOR FRAMING 1" = 1'-0"8 FLOOR FRAMING 3/4" = 1'-0"9 TYP. BEAM TO HSS COLUMN 3/4" = 1'-0"10 PERIMETER ROOF FRAMING 3/4" = 1'-0"11 PERIMETER ROOF FRAMING 1" = 1'-0"13 FLOOR FRAMING 3/4" = 1'-0"14 STAIR FRAMING DETAIL 3/4" = 1'-0"15 PERIMETER ROOF FRAMING 1/2" = 1'-0"12 FRAMING DETAIL PRE-ENGINEERED WOOD ROOF TRUSS BY TRUSS SUPPLIER WF BEAM, SEE PLAN 2x NAILER -FASTEN TO BEAM w/ 1/2"Ø CARRIAGE BOLTS @ 24" O.C. (STAGGERED). NAILER TO OVERHANG BEAM (1/2" MAX). SEE PLAN T/ STEEL TRUSS TIE DOWN CLIPS BY TRUSS DESIGNER SEE PLAN T/ STEEL DOUBLE STUDS @ EACH SIDE OF BLOCKING 3/4"Ø STEEL TIE ROD #3 CLEVIS, TYP. HSS BEAM, SEE PLAN FINISH w/ 3 PART TNEMEC PAINT KNIFE PL1/2 w/ 1"Ø HOLE FLOOR JOIST, SEE PLAN FLOOR SHEATHING SEE PLAN SEE GENERAL NOTE FOR NAILING SEE PLAN JOIST BEARING SEE PLAN T/ STEEL 1 1/2"1 1/2" 3"1 1/2"1 1/2"11 1/4"DOUBLE STUDS @ EACH SIDE OF BLOCKING SIMPSON HUC410 HANGER @ EA. SIDE 1/4 SECTION A-A (2) 2x12 BLOCKING 1/2" PLATE w/ (4) 1/2"Ø THRU BOLTS SIMPSON A35 FRAMING ANGLE TOP & BOTTOM OF BLOCKIING SIMPSON A35 FRAMING ANGLE TOP & BOTTOM @ CANOPY LOCATION A A C12x20.7 w/ 3/4" LAG BOLTS @ 18" O.C. 6"7"7" PLUM DESIGN SERVICE, INC. ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS. WE ARE NOT A LICENSED ARCHITECT OR ENGINEER. THESE PLANS ARE PROVIDED ON AN "AS IS" BASIS AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND/OR OWNER TO VERIFY AND CHECK ALL NOTES, DETAILS, ELEVATIONS, SECTIONS, AND FLOOR PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR AND/OR OWNER SHALL NOTIFY PLUM DESIGN SERVICE, INC. IMMEDIATELY IF ANY ERRORS OR OMISSION FOR POSSIBLE CORRECTION ARE IDENTIFIED PRIOR TO START OF CONSTRUCTION. NO WARRANTIES EXPRESS OR IMPLIED INCLUDING COMPLIANCE WITH THIS PLAN WITH APPLICABLE BUILDING CODES REQUIREMENTS ARE MADE. DATE: DATE: DATE: PROJECT ID: 1100 SE ALICE'S ROAD. WAUKEE, IOWA 50263 PLUM DESIGN SERVICES DATE: DATE: DATE: ISSUE DATE: DATE: DATE: TELEPHONE 515 978 6260 FAX 515 978 6261 THIS PAGE IS INTENDED TO BE PRINTED ON 24"X36" PAPER TO BE TO SCALE DATE:NOT FOR CONSTRUCTION3/4" = 1'-0" S-402 FRAMING DETAILS RRE19164Element 119OfficesWaukee, IowaIssue Date 3/4" = 1'-0"2 TRUSS BEARING @ WF BEAM 3/4" = 1'-0"1 SECTION @ CANOPY Black Shadow Ledge Stone TPO Coated Metal Roof Slate Gray Windows, doors and Trim Trincorn Black SW 6258 Hardie STUCCO - Gray Slate (Front of building) Hardie Plank Lap siding Cobble stone (Front of Building) Cobble Stone Hardie STUCCO - Iron Gray (Accent Color/ Front & Side) Iron Gray Cobble Stone Gray Slate Iron Gray Aged Pewter Hardi Plank Lap Siding (Both sides and back of building) Stratford Crossing Light Industrial Gray Slate