CITY OF WAUKEE, IOWA
CITY COUNCIL MEETING COMMUNICATION
MEETING DATE: August 17, 2020
AGENDA ITEM: Consideration of approval of a resolution approving a site plan for Elite Eye
Care (1350 SE University Avenue)
FORMAT: Resolution
SYNOPSIS INCLUDING PRO & CON: Elite Eye Care, requests approval of a site plan to allow the
construction of a 13,500 square foot building. The building is to be used for an
Elite Eye Care clinic. In addition to the eye clinic there are two tenant spaces
proposed on the east side of the building. Access to the site will be provided
from SE University Avenue and SE Bishop Drive.
The applicant has provided elevations for the proposed building on the site,
which meets the intent of the architectural guidelines within the Site Plan
Ordinance.
FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS:
COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning
Commission reviewed this project at the August 11, 2020 Commission Meeting and
recommended approval subject to remaining staff comments:
Approval of a Site Plan for Elite Eye Care (1350 SE University Ave)
Senior City Planner, Melissa DeBoer, introduced the request for approval of a site plan as submitted
by the applicant, Elite Eye Care, for an optometrist office. The property is generally located south of
SE University Avenue and west of SE Waco Place, containing approximately 1.72 acres.
Mrs. DeBoer advised that the project includes the construction of a single- story, multi-tenant building,
approximately 13,500 square feet in area. The building would house Elite Eye Care with
approximately 3,436 square feet available for a future tenant. The site plan also indicates a trash
enclosure on the southwest corner of the site, a monument sign at the northeast corner of the site, and
approximately 63 parking spaces. Access is provided from public streets to the south and north of the
site and sidewalks are proposed along these public streets and interior to the site. Public utilities will
serve the site, and storm water detention will be provided with a detention basin located on the west
side of the site. All landscaping, open space, elevation, and lighting requirements have been met at
this time.
Staff would recommend approval of the site plan, subject to any remaining staff comments.
Commissioner Streit questioned if there is a potential for a drive thru in the second tenant
space. Mrs. DeBoer advised that there are no cueing spaces presented on the site plan,
indicating no use of a drive thru.
J5
Commissioner Streit questioned if the second tenant would be GNC as their sign is used in the
elevations. Jim Trinell, a representative for the applicant, advised that the signage on the
elevation was for presentation purposes only to indicate the maximum signage allowances to
the applicant. There is no known second tenant at this time.
Commissioner Broderick moved to approve a site plan for elite Eye Care (1350 SE University Ave)
subject to any remaining staff comments. The motion was seconded by Commissioner Streit. Ayes:
Streit, Conley, Koshy, Broderick, and Hoifeldt. Nays: None. Motion Carries.
STAFF REVIEW AND COMMENT: Staff is working with the applicant to address that last
remaining comments. Staff recommends approval of the site plan subject to
remaining staff comments.
RECOMMENDATION: Approve the resolution subject to remaining staff comments.
ATTACHMENTS: I. Proposed Resolution
II. Staff Report
III. Site Plan & Elevations
PREPARED BY: Andy Kass, Senior Planner
REVIEWED BY:
THE CITY OF WAUKEE, IOWA
RESOLUTION 2020-
APPROVING THE SITE PLAN FOR ELITE EYE CARE
(1350 SE UNIVERSITY AVENUE)
IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA
WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal
Organization; AND,
WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of
the Site Plan for Elite Eye Care, subject to remaining staff comments on August 11, 2020; AND,
WHEREAS, the Site Plan for Elite Eye Care is in general conformance with §160 – Site and
Building Development Standards Ordinance of the Waukee Municipal Code; AND,
WHEREAS, the Site Plan for Elite Eye Care is in general conformance with §161 –
Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND,
NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on
this 21st day of August, 2020 that the Site Plan for Elite Eye Care is approved subject to
remaining staff comments.
BE IT FURTHER RESOLVED that the City of Waukee does hereby accept the following
easements related to the site plan to be filed with the Dallas County Recorder:
1. Detention Easement
____________________________
Courtney Clarke, Mayor
Attest:
___________________________________
Rebecca D. Schuett, City Clerk
RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN
Anna Bergman
R. Charles Bottenberg
Chris Crone
Larry R. Lyon
Ben Sinclair
PLANNING AND ZONING COMMISSION STAFF REPORT
PROJECT: Elite Eye Care – Site Plan PREPARED BY: Melissa DeBoer, AICP – Senior Planner
REPORT DATE: August 7, 2020
MEETING DATE: August 11, 2020
GENERAL INFORMATION
Owner: Hawthorne Pointe, LLC
Applicant: Elite Eye Care
Owner’s Representative:
Korey Marsh, PE – Snyder & Associates, Inc.
Request: The applicant is requesting approval of a site plan for
an optometrist office.
Location and Size: Property is generally located south of SE University
Avenue and west of SE Waco Place, containing
approximately 1.72 acres.
Property Address: 1350 SE University Avenue
AREA MAP
ABOVE: Aerial of Property identifying the proposed plat (outlined in BLUE).
August 7, 2020
2 of 3
LAND USES AND ZONING
Location Existing Land Use Comprehensive Plan Current Zoning
Property in
Question
Vacant –
Undeveloped Community
Commercial
C-1 / PD-1 (Community and Highway
Service Commercial District / Planned
Development District)
North Multi-Family
Residential / Single
Family Residential
High Density
Residential / Single
Family Residential
R-3 / PD-1 (Multi-Family Residential
District / Planned Development District);
C-4 / PD-1 (Office Park Commercial
District / Planned Development District);
R-2 / PD-1 (One and Two Family
Residential District / Planned
Development District)
South Apartments /
Townhomes
Medium Density
Residential
C-1 / PD-1 (Community and Highway
Service Commercial District / Planned
Development District)
East Vacant –
Undeveloped
Community
Commercial
C-1 / PD-1 (Community and Highway
Service Commercial District / Planned
Development District)
West Commercial Community
Commercial
C-1 / PD-1 (Community and Highway
Service Commercial District / Planned
Development District)
PROJECT DESCRIPTION
The project includes the construction of a single-story, multi-tenant building. The building is proposed to be
about 13,500 square feet in area. The majority of the building will be the space for Elite Eye Care (10,080 sq
ft) and a smaller tenant space (3,436 sq ft) will be available for a future tenant. The main entrance to the
building is located on the north side, facing SE University Avenue.
A trash enclosure is proposed at the southwest corner of the site and a monument sign is shown at the
northeast corner of the site, along SE University Avenue.
ACCESS AND PARKING
There are two accesses into this site from the public streets. One is located to the south off of SE Bishop
Drive and this is a shared access with the dentist office to the west. The other access is located to the north
off of SE University Avenue.
A total of 41 parking spaces are required for this facility. The total amount of parking proposed is 63 spaces
including 3 accessible stalls. The site plan also identifies a bicycle rack located on the north side of the building.
The proposed site plan meets the parking requirements. The site plan also calls out an area at the south side
of the site as future parking; this includes a possibility of 18 spaces if needed at some point in the future.
August 7, 2020
3 of 3
SIDEWALKS/TRAILS
Five foot wide sidewalks will be installed along SE Bishop Drive on the south and SE University Avenue on the
north. Sidewalks are proposed interior to the site in order to provide pedestrian connections from the
parking lot to the proposed building and around the building.
UTILITIES
This site will be serviced with all public utilities. Water and sanitary sewer will be brought in from the mains
located to the south along SE Bishop Drive. Storm water detention will be provided with a detention basin
located at the west side of the site.
LANDSCAPING & OPEN SPACE
A minimum of 15% of the project area is required to be open space. The total amount of open space
proposed is 39%. The landscape plan meets the requirements of the Landscape and Open Space Ordinance
and the Kettlestone Design Guidelines.
ELEVATIONS
The elevations of the building are proposed to be constructed mostly of composite wood siding, brick,
architectural metal accents, aluminum storefront system and a metal roof.
MISCELLANEOUS:
The applicant has submitted a photometric plan and associated light fixture cut sheets. The lighting plan meets the
lighting requirements of the Site Plan Ordinance.
COMPREHENSIVE PLAN
The comprehensive plan classifies the subject property as Community Commercial. The Community
Commercial classification provides a variety of uses that would serve the community and are located along
minor or major arterials.
STAFF RECOMMENDATION
The site plan is in general conformance with the Site Plan Ordinance and Comprehensive Plan. Staff
recommends approval of the site plan for Elite Eye Care subject to remaining staff comments.
1"= 120.0504KMMEDCRMM120.050488WAUKEE, IOWA BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= ZARNESONV:\Projects\2020\120.0504.01\CADD\SP_1200504_01TSH.dgn7/22/20205:05:23 PMSnyder1:500Y:\pen\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of
Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS06/23/20RMM6/09/2020ELITE EYE CARE - WAUKEE2REVISED AS PER CITY COMMENTS07/07/20RMM3REVISED AS PER CITY COMMENTS07/22/20RMMINDEX OF SHEETS
PROJECT LOCATION
VICINITY MAP
STATE OF
IO
WA
PROFESSIO
N
ALLANDSCAPE AR CHITECTDate
License Number
Pages or sheets covered by this seal:
668
NO.
ARCHITECT
LANDSCAPE
under the laws of the State of Iowa.
Professional Landscape Architect
charge. I am a duly licensed
direct supervision and responsible
below was prepared by me or under my
this technical submission described
I hereby certify that the portion of
June 30, 2018
License Expires:
668
GULDENPFENNIG
LARA F.
Lara F. Guldenpfennig, ASLASE BRICK DRSE ALICE'S RDSE UNIVERSITY AVE.98TH STREETGRAND PRARIE PKWY1TITLE SHEET1
OWNER
8.
7.
6.
5.
4.
3.
2.
1.500'1"=500'
CITY OF WAUKEE, DALLAS COUNTY, IOWA
1350 SE UNIVERSITY AVENUE
FOR
SITE PLAN
LANDSCAPE PLAN
SIDEWALK RAMP DETAILS
EROSION AND SEDIMENT CONTROL PLAN
GRADING PLAN
UTILITY PLAN
DIMENSION PLAN
PROJECT INFORMATION
TITLE SHEET
SHEET 1-7
SHEET 8
State of Iowa.
Professional Engineer under the laws of the
supervision and that I am a duly licensed
was prepared by me or under my direct personal
I hereby certify that this engineering document
Date
License Number
My License Renewal Date is December 31, 2020
Pages or sheets covered by this seal:
P25347LICENSEDPROFEIONALEN
GI
NEERAIOW
SS
Korey M. Marsh, P.E.
P25347
MARSH
KOREY M.
DR
SE BISHOP SE EMERALD DRARCHITECT
PHONE: (319) 987-2101
CONACT: DANIEL HALBACH
JANESVILLE, IA 50647
P.O. BOX 461
201 MAIN STREET
MODERN DESIGN ARCHITECTS
ELITE EYE CARE - WAUKEE
EMAIL: JJOHNSON@ACCURATEDEVELOPMENT.COM
PHONE: 515-566-0124
CONTACT: JARED T JOHNSON
WEST DES MOINES, IA 50266
9500 SE UNIVERSITY AVE SUITE 2112
HAWTHORNE POINTE, LLC
1"= 120.0504KMMEDCRMM120.050488WAUKEE, IOWA BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= ZARNESONV:\Projects\2020\120.0504.01\CADD\SP_1200504_02NTS.dgn7/22/20205:05:24 PMSnyder1:1Y:\pen\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of
Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS06/23/20RMM6/09/2020ELITE EYE CARE - WAUKEE2REVISED AS PER CITY COMMENTS07/07/20RMM3REVISED AS PER CITY COMMENTS07/22/20RMM2 2PROJECT INFORMATIONPARKING REQUIREMENTS:
93
93.0
93
C
OC
FO
E
OE
4" G
4" HPG
8" W
8" S
12" ST12" ST
G
G
AST
UST
Features Existing Proposed
G
EB
W
LEGEND
8" W(*)
8" S(*)
4" G(*)
4" HPG(*)
C(*)
OC(*)
FO(*)
E(*)
OE(*)
DUCT(*)
93.0
1
Soil Boring
Mailbox
Satellite Dish
Sign
Above Ground Storage Tank
Underground Storage Tank
Fence Post or Guard Post
Gas Apparatus
Gas Manhole
Gas Valve
Fiber Optic Handhole
Fiber Optic Manhole
Communication Handhole
Communication Manhole
Communication Pedestal
Traffic Sign
Electric Transformer
Electric Box
Yard Light
Street Light
Utility Pole with Transformer
Utility Pole with Light
Guy Anchor
Utility Pole
Well
Water Service Valve
Water Main Valve
Fire Hydrant on Building
Fire Hydrant
Double Storm Sewer Intake
Single Storm Sewer Intake
Storm Manhole
Storm Sewer with Size
Sanitary Manhole
(*) Denotes the survey quality service level for utilities
Test Hole Location for SUE w/ID
Duct Bank
Sanitary Sewer with Size
Water Main with Size
High Pressure Gas Main with Size
Gas Main with Size
Overhead Electric
Underground Electric
Fiber Optic
Overhead Communication
Communication
Coniferous Tree or Shrub
Deciduous Tree or Shrub
Tree Stump
Tree Line
Fence (Silt)
Fence (Wood)
Fence (Chain Link)
Fence (Barbed, Field, Hog)
Contour Elevation
Spot Elevation
UTILITY WARNING
UTILITY QUALITY SERVICE LEVELS
THE TYPE, SIZE, CONDITION, MATERIAL, AND OTHER CHARACTERISTICS.
BY ACTUAL EXPOSURE OR VERIFICATION OF PREVIOUSLY EXPOSED SUBSURFACE UTILITIES, AS WELL AS
IS HORIZONTAL AND VERTICAL POSITION OF UNDERGROUND UTILITIES OBTAINEDQUALITY LEVEL (A)
SUBSURFACE UTILITIES.
GEOPHYSICAL METHODS TO DETERMINE THE EXISTENCE AND APPROXIMATE HORIZONTAL POSITION OF
INFORMATION IS OBTAINED THROUGH THE APPLICATION OF APPROPRIATE SURFACE QUALITY LEVEL (B)
QUALITY D INFORMATION.
UTILITY FEATURES AND USING PROFESSIONAL JUDGMENT IN CORRELATING THIS INFORMATION WITH
INFORMATION IS OBTAINED BY SURVEYING AND PLOTTING VISIBLE ABOVE-GROUND QUALITY LEVEL (C)
INFORMATION IS DERIVED FROM EXISTING UTILITY RECORDS OR ORAL RECOLLECTIONS.QUALITY LEVEL (D)
APPLICABLE, SIZE. THE QUALITY LEVELS ARE BASED ON THE CI / ASCE 38-02 STANDARD.
QUALITY LEVELS OF UTILITIES ARE SHOWN IN THE PARENTHESES WITH THE UTILITY TYPE AND WHEN
EXCEPT WHERE NOTED AS QUALITY LEVEL A.
UTILITIES OR SUBSURFACE FEATURES SHOWN ARE IN THE EXACT LOCATION INDICATED
SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE
SUBSURFACE FEATURES SHOWN COMPRISE ALL SUCH ITEMS IN THE AREA, EITHER IN
RECORDS OBTAINED. THE SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES OR
THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR
GENERAL NOTES
BULK REGULATIONS
ZONING
GENERAL USE
IMPERVIOUS AREA
PERVIOUS AREA
LEGAL DESCRIPTION
53,014 SF
22,025 SF
TOTAL AREA OF DISTURBANCE
1.72 AC
BEING AN OFFICIAL PLAT DALLAS COUNTY, IOWA.
LOT 1, COVE AT KETTLESTONE PLAT 3
RECORDED WITH BOOK 2016 PAGE 2362
COMMERCIAL DISTRICT)
(COMMUNITY AND HIGHWAY SERVICE
PLANNED UNIT DEVELOPMENT/ C-1
RETAIL/GENERAL COMMERCIAL N/ANAD83(2011)(EPOCH 2010.00) IARTN DERIVED - US SURVEY FEET
IOWA STATE PLANE SOUTH COORDINATE SYSTEM
CONTROL POINTS
BENCHMARKS
IARTN DERIVED - US SURVEY FEET
NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88 - GEOID12A)
CP4
CP3
CP2
CP1
BM2
BM1
SOUTH SIDE SE BISHOP DRIVE.
BURY BOLT ON HYDRANT, IN FRONT OF UNIT #1296,
ELEV=1062.50
SOUTH SIDE SE BISHOP DRIVE.
BURY BOLT ON HYDRANT, IN FRONT OF UNIT #1356,
ELEV=1061.03
COOPERATE TO PROVIDE INFORMATION UNDER THE RESPONSIBILITY OF OTHERS.f.
UPDATE AND MAINTAIN THE ONSITE SWPPP.e.
WEEKLY INSPECTIONS AND CORRESPONDING RECORDS.d.
MEASURES.
INSTALL, MAINTAIN, AND REMOVE EROSION CONTROL AND POLLUTION PREVENTION c.
COMPLY WITH THE REQUIREMENTS OF THE GENERAL PERMIT No.2 AND THE SWPPP.b.
CERTIFICATION OF SUBCONTRACTOR CO-PERMITEES.
SIGN NPDES CERTIFICATION STATEMENT AS CO-PERMITEE AND COORDINATING a.
RESPONSIBILITIES OF THE CONTRACTOR:3.
SUBMIT THE NOTICE OF DISCONTINUATION.d.
COVERAGE.
FILE THE NOTICE OF INTENT WITH APPLICATION FEE FOR NPDES GENERAL PERMIT No. 2 c.
PUBLISH THE PUBLIC NOTICE OF STORM WATER DISCHARGE.b.
CREATE THE INITIAL SWPPP.a.
RESPONSIBILITIES OF THE ENGINEER:2.
b. ALL REQUIREMENTS NOT ASSIGNED TO OTHERS.
a. SIGN NPDES CERTIFICATION STATEMENT AS PERMITEE.
RESPONSIBILITIES OF THE OWNER:1.
PROJECT SPECIFIC REQUIREMENTS FOR POLLUTION PREVENTION AND EROSION PROTECTIOND.
FILING OF THE "NOTICE OF DISCONTINUATION".
REMOVE ALL TEMPORARY EROSION CONTROL MEASURES AND SITE WASTE PRIOR TO k.
MUST BE CONTAINED ONSITE.
SEDIMENT BASIN OR OTHER CONTROL DEVICE WHERE POSSIBLE. CONCRETE WASHOUT
STAGING AREAS WITH DIVERSION BERMS AND/OR SILT BARRIERS AND DIRECT TO A
MATERIALS STORAGE, AND CONCRETE WASHOUT FACILITY. CONTROL RUNOFF FROM
JOB TRAILERS, FUELING / VEHICLE MAINTENANCE AREA, TEMPORARY SANITARY FACILITIES,
SWPPP. UNLESS NOTED OTHERWISE, STAGING AREAS SHOULD CONTAIN THE FOLLOWING:
COORDINATE LOCATIONS OF STAGING AREAS WITH THE OWNER AND RECORD IN THE j.
EXCEEDING 14 CALENDAR DAYS.
CEASED ON ANY PORTION OF THE SITE AND WHICH WILL NOT RESUME FOR A PERIOD
IMMEDIATELY AFTER CONSTRUCTION ACTIVITY IS FINALLY COMPLETED OR TEMPORARILY
COMPLETION OR DELAY OF GRADING OPERATIONS. INITIATE STABILIZATION MEASURES
PERMANENT SEED MIX, SOD, OR PAVEMENT IMMEDIATELY AS SOON AS POSSIBLE UPON
STABILIZE UNDEVELOPED, DISTURBED AREAS WITH MULCH, TEMPORARY SEED MIX, i.
ARE LOCATED.
ALL DISTURBED AREAS, EXCEPT WHERE PAVEMENT, BUILDINGS OR OTHER IMPROVEMENTS
RESPREAD A MINIMUM OF 8 INCHES OF TOPSOIL (INCLUDING TOPSOIL FOUND IN SOD) ON h.
SEWERS ARE INSTALLED.
RUNOFF CONTROL. PROVIDE INLET AND OUTLET CONTROL MEASURES AS SOON AS STORM
GRADES AND AS CONSTRUCTION OPERATIONS PROGRESS TO ENSURE CONTINUOUS
MATS, MULCH, DITCH CHECKS OR RIPRAP AS SOON AS AREAS REACH THEIR FINAL
INSTALL NECESSARY CONTROL MEASURES SUCH AS SILT BARRIERS, EROSION CONTROL g.
DEBRIS IMMEDIATELY AND TAKE REMEDIAL ACTIONS FOR FUTURE PREVENTION.
DRAINAGEWAYS, OR UNDERGROUND SEWERS. REMOVE ANY ACCUMULATION OF EARTH OR
ADJOINING PUBLIC OR PRIVATE PROPERTIES, INCLUDING STREETS, DRIVEWAYS, SIDEWALKS,
PREVENT ACCUMULATION OF EARTH AND DEBRIS FROM CONSTRUCTION ACTIVITIES ON f.
SWPPP AND IMPLEMENT ANY RECOMMENDED MEASURES WITHIN 7 DAYS.
SUBMITTED WEEKLY TO THE OWNER OR ENGINEER DURING CONSTRUCTION. REVISE THE
OF THESE INSPECTIONS AND ANY RESULTING ACTIONS IN THE SWPPP WITH A COPY
ASSIGNED BY THE CONTRACTOR) EVERY SEVEN CALENDAR DAYS. RECORD THE FINDINGS
INSPECT THE PROJECT AREA AND CONTROL DEVICES (BY QUALIFIED PERSONNEL e.
THE MEASURES HAVE LOST 50% OF THEIR ORIGINAL CAPACITY.
THROUGHOUT THE PERMIT PERIOD. CLEAN OR REPLACE SILT CONTROL DEVICES WHEN
ORDER, INCLUDING CLEANING, REPAIRING, REPLACEMENT, AND SEDIMENT REMOVAL
MAINTAIN ALL TEMPORARY AND PERMANENT EROSION CONTROL MEASURES IN WORKING d.
TIME.
TO A MINIMUM THE TOTAL AREA DISTURBED BY CONSTRUCTION OPERATIONS AT ANY
PRESERVE EXISTING VEGETATION IN AREAS NOT NEEDED FOR CONSTRUCTION AND LIMIT c.
DISTURBING ACTIVITIES PRIOR TO SITE CLEARING AND GRADING OPERATIONS.
DITCH CHECKS, DIVERSION BERMS, OR SEDIMENTATION BASINS DOWNSTREAM OF SOIL
INSTALL PERIMETER AND FINAL SEDIMENT CONTROL MEASURES SUCH AS SILT BARRIERS, b.
AND MAXIMIZE STORM WATER INFILTRATION, AND MINIMIZE SOIL COMPACTION.
WATERS, DIRECT STORM WATER TO VEGETATED AREAS TO INCREASE SEDIMENT REMOVAL
DISCHARGING FROM BASINS, PROVIDE AND MAINTAIN NATURAL BUFFERS AROUND SURFACE
UTILIZE OUTLET STRUCTURES THAT WITHDRAW WATER FROM THE SURFACE WHEN a.
UNLESS INFEASIBLE OR NOT APPLICABLE:
GENERAL PERMIT AND SWPPP, INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING BMP'S
THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL REQUIREMENTS OF THE 4.
PROGRESS AND CHANGES AT THE PROJECT SITE.
THE SWPPP AND SITE MAP SHOULD BE EXPEDITIOUSLY REVISED TO REFLECT CONSTRUCTION 3.
FROM THOSE SHOWN ON THE PLAN MAY BE REQUIRED.
RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY, NOTE AND IMPLEMENT. ADDITIONAL BMP'S
CONTROL MEASURES REQUIRED AS A RESULT OF CONSTRUCTION ACTIVITIES ARE THE
COMPLIANCE WITH THE PROJECT'S NPDES PERMIT COVERAGE. ALL BMP'S AND EROSION
THE SWPPP ILLUSTRATES GENERAL MEASURES AND BEST MANAGEMENT PRACTICES (BMP) FOR 2.
DURING CONSTRUCTION.
ADDITIONAL REQUIREMENTS AND MODIFICATIONS TO THE POLLUTION PREVENTION PLAN MADE
ADDITION TO THESE PLAN DRAWINGS. THE CONTRACTOR SHOULD REFER TO THE SWPPP FOR
THE STORM WATER POLLUTION PREVENTION PLAN (SWPPP) IS A SEPARATE DOCUMENT IN 1.
C. POLLUTION PREVENTION PLAN
AND/OR SUBMITTAL OF THE NOTICE OF DISCONTINUATION.
COPY AND PROVIDE THE ORIGINAL DOCUMENTS TO THE OWNER UPON PROJECT ACCEPTANCE
OF THREE YEARS AFTER PROJECT COMPLETION. THE CONTRACTOR SHALL RETAIN A RECORD
ALL PLANS, INSPECTION REPORTS, AND OTHER DOCUMENTS MUST BE RETAINED FOR A PERIOD
OF THE DISTURBED SITE AND REMOVAL OF ALL TEMPORARY EROSION CONTROL MEASURES.
A "NOTICE OF DISCONTINUATION" MUST BE FILED WITH THE IDNR UPON FINAL STABILIZATION 3.
WATER ACT AND THE CODE OF IOWA.
FAILURE TO COMPLY WITH THE NPDES PERMIT REQUIREMENTS IS A VIOLATION OF THE CLEAN
AT ALL TIMES AND MUST BE PRESENTED TO ANY JURISDICTIONAL AGENCIES UPON REQUEST.
LETTER, CURRENT SWPPP, SITE INSPECTION LOG, AND OTHER ITEMS, SHALL BE KEPT ON SITE
LIMITED TO, THE NOTICE OF INTENT, PROOF OF PUBLICATIONS, DISCHARGE AUTHORIZATION
ALL DOCUMENTS RELATED TO THE STORM WATER DISCHARGE PERMIT, INCLUDING, BUT NOT 2.
DOCUMENTS.
ALL REQUIREMENTS OF THE NPDES GENERAL PERMIT NO. 2 AS SPECIFIED IN THE CONTRACT
AND ALL SUBCONTRACTORS ARE RESPONSIBLE FOR COMPLIANCE WITH AND FULFILLMENT OF
REQUIRED BY THE ENVIRONMENTAL PROTECTION AGENCY (EPA). THE GENERAL CONTRACTOR
WATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITIES FROM THE IDNR, AS
THIS PROJECT REQUIRES COVERAGE UNDER THE NPDES GENERAL PERMIT NO. 2 FOR STORM 1.
B. STORM WATER DISCHARGE PERMIT
ITEMS AND DEDUCT THE COST THEREOF FROM AMOUNTS DUE TO THE CONTRACTOR.
ADJOINING PUBLIC OR PRIVATE PROPERTY, THE OWNER MAY, BUT NEED NOT, REMOVE SUCH
STEPS TO PROMPTLY REMOVE EARTH SEDIMENTATION OR DEBRIS WHICH COMES ONTO
FEES INCURRED TO OWNER. FURTHER, IF THE CONTRACTOR FAILS TO TAKE NECESSARY
DAMAGES TO ADJOINING PUBLIC OR PRIVATE PROPERTY, INCLUDING REASONABLE ATTORNEY
HARMLESS FROM ANY AND ALL CLAIMS OF ANY TYPE WHATSOEVER RESULTING FROM
DAMAGE CLAIMS: THE CONTRACTOR WILL HOLD THE OWNER AND ARCHITECT / ENGINEER 2.
BORROW OR DEPOSIT AREAS DURING PERFORMANCE OR AS A RESULT OF PERFORMANCE.
PROTECT AGAINST EROSION AND POLLUTION FROM THIS PROJECT SITE AND ALL OFF-SITE
ANY LOCAL ORDINANCES. THE CONTRACTOR SHALL TAKE ALL NECESSARY STEPS TO
DEPARTMENT OF NATURAL RESOURCES (IDNR) NPDES PERMIT, THE U.S. CLEAN WATER ACT AND
POLLUTION AND SOIL EROSION CONTROL REQUIREMENTS OF THE IOWA CODE, THE IOWA
CODE COMPLIANCE: THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL POTENTIAL 1.
A. POLLUTION PREVENTION AND EROSION PROTECTION
POLLUTION PREVENTION NOTES
UTILITY CONTACT INFORMATION
SYSTEM, TICKET NUMBER 552003655.
RECEIVED FROM THE IOWA ONE CALL DESIGN REQUEST
UTILITY CONTACT FOR MAPPING INFORMATION SHOWN AS
JACK@GRM.NET
515-897-9192
JACK JONES
MI-FIBER
PMAY@MEDIACOMCC.COM
515-246-2252
PAUL MAY
MEDIACOM COMMUNICATIONS CORP
LOCATES@ICS-LLC.NET
515-268-4045
ADAM WOODARD
INTERNET CONSULTING SERVICES,
JUSTIN.GREV@CONSOLIDATED.COM
507-386-3606
JUSTIN GREV
CONSOLIDATED COMMUNICATIONS
THOMAS.STURMER@CENTURYLINK.COM
720-578-8090
TOM STURMER
CENTURYLINK
JEFF.KLOCKO@AUREON.COM
515-830-0445
JEFF KLOCKO
AUREON NETWORK SERVICES
NO RESPONSE
CLEAR
NO RESPONSE
NO RESPONSE
C1-COMMUNICATIONS
FO2-FIBER OPTIC
F01-FIBER OPTIC
G-GAS
S-SANITARY SEWER
W-WATER
FO4-FIBER OPTIC
FO3-FIBER OPTIC
NO RESPONSE
OE-OVERHEAD ELECTRIC
E-ELECTRIC
TROYER@WAUKEE.ORG
515-978-7920
TIM ROYER
WAUKEE, CITY OF
LOCATE.DESK@WINDSTREAM.COM
800-289-1901
LOCATE DESK
WINDSTREAM COMMUNICATIONS
UPNGIS@UPNFIBER.COM
816-425-3556
JOE KILZER
UNITE PRIVATE NETWORKS, LLC
RYAN@NEXGENCOM.COM
515-369-7131
RYAN ROLWES
NEXGEN INTEGRATED COMMUNICATIO
MECDSMDESIGNLOCATES@MIDAMERICAN.COM
515-252-6632
CRAIG RANFELD
MIDAMERICAN ENERGY
}20' NORTH OF POWER POLE, }75' SOUTH OF HYDRANT.
SET CUT "X" AT SOUTH BACK OF CURB SE UNIVERSITY AVE,
N=583246.40 E=1545986.91 ELEV=1058.54
}5' NORTH OF STREET LIGHT, }150' EAST OF EMERALD DRIVE.
SET CUT "X" AT SOUTH BACK OF CURB SE UNIVERSITY AVE,
N=583247.92 E=1545528.02 ELEV=1058.62
SOUTH ENTRANCE.
BISHOP DRIVE, }5' NORTH OF STREET LIGHT, }50' WEST OF
SET CUT "X" AT SOUTH BACK OF CURB INTAKE OF SE
N=582898.81 E=1545491.01 ELEV=1060.50
ENTRANCE.
SIDE OF SE BISHOP DRIVE, }40' WEST OF TOWNHOME
SET CUT "X" AT DOUBLE BACK OF CURB INTAKE, SOUTH
N=582886.23 E=1545932.77 ELEV=1058.72
MINIMUM OPEN SPACE = 15%
ADJACENT TO RESIDENTIAL
REAR YARD = NONE EXCEPT FOR 25 FEET
ADJACENT TO RESIDENTIAL
SIDE YARD = NONE EXCEPT FOR 10 FEET
LOT AREA = NONE
FRONT YARD= ZERO (0') MINIMUM , NO MAXIMUM
ACCESSIBLE SPACES )
(INCLUDING 3 HANDICAP
63 SPACES PROVIDED
41 SPACES REQUIRED
(13,516 SF / 1000 SF) x 3 SPACES =41 SPACES
RETAIL/ GENERAL COMMERCIAL:
3 SPACES PER 1000 SF OF PROFESSIONAL/BUSINESS OFFICES
AROUND THE EXTERIOR OF THE BUILDING OR FACILITY.
OF THE EXTERIOR WALLS OF THE FIRST STORY OF THE BUILDING AS MEASURED BY AN APPROVED ROUTE
THE REQUIREMENTS OF SECTION 503.2 AND THIS SECTION SHALL EXTEND TO WITHIN 100 FEET OF ALL PORTIONS
A BUILDING AS SOON AS CONSTRUCTION COMMENCES. THE FIRE APPARATUS ACCESS ROAD SHALL COMPLY WITH
EE. APPROVED FIRE APPARATUS ACCESS ROADS SHALL BE PROVIDED FOR EVERY FACILITY, BUILDING, OR PORTION OF
COORDINATE ANY LANE/ROAD CLOSURES WITH THE CITY OF WAUKEE.
NOTIFYING DRIVERS OF LANE CLOSURES AT LEAST ONE WEEK PRIOR TO ANY CLOSURE. CONTRACTOR IS TO
DD. PRIOR TO ANY LANE CLOSURE THE CONTRACTOR IS RESPONSIBLE FOR HAVING A DIGITAL MESSAGE BOARD
CONSTRUCTION.
CC. CONTRACTOR IS TO PROVIDE SHOP DRAWING SUBMITTALS OF CONSTRUCTION MATERIALS PRIOR TO
BB. ALL FIRE HYDRANTS WILL BE REQUIRED TO HAVE 4-INCH STORZ FITTINGS.
AND CITY OF WAUKEE ENGINEERING DEPARTMENT SHALL WITNESS ALL TIE-INS.
AA. CONTRACTOR SHALL COORDINATE ALL TIE-IN TO UTILITIES WITH THE CITY OF WAUKEE ENGINEERING DEPARTMENT
SLURRY FROM CONCRETE OPERATIONS TO DISCHARGE OFFSITE.
Z. CONSTRUCTION OPERATIONS SHALL PROTECT STORM SEWERS AND DRAINAGE WAYS FROM ALLOWING CONCRETE
SHALL WITNESS ALL TESTING.
SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND ALL UTILITIES SHALL BE TESTED TO CITY STANDARDS. THE CITY
Y. ALL UTILITIES INCLUDING PRIVATE UTILITIES SHALL BE CONSTRUCTED TO THE CITY OF WAUKEE STANDARD
SHALL PROVIDE INFORMATION TO THE DESIGN ENGINEER FOR INCLUSION ON THE RECORD AS-BUILT DRAWINGS.
GRADES FOR DRAINAGE SWALES, OVERFLOWS, ACCESSIBLE RAMPS AND DETENTION FACILITIES. THE CONTRACTOR
X. AS-BUILTS SHALL BE PROVIDED TO THE WAUKEE ENGINEERING DEPARTMENT INCLUDING ALL UTILITIES AND AS-BUILT
EXPANSION JOINTS SHALL BE SEALED.
JOINT BETWEEN SIDEWALKS AND PCC PAVEMENT. THE PCC RAMP JOINT LOCATED AT THE BACK OF CURB AND ALL
W. PLACE 3/4" EXPANSION JOINT BETWEEN ALL PCC PAVEMENT/SIDEWALKS AND BUILDINGS. PLACE 1/2" EXPANSION
TO THE CITY OF WAUKEE. ALL SANITARY SEWER MANHOLES SHALL BE VACUUM TESTED.
WAUKEE SHALL WITNESS ALL CLEANING AND TELEVISING. COPIES OF THE REPORT AND VIDEO SHALL BE PROVIDED
V. ALL SANITARY SEWER AND STORM SEWER SHALL BE CLEANED AND TELEVISED PRIOR TO PAVING. THE CITY OF
GRANTED APPROVAL IN WRITING BY THE CITY OF WAUKEE DEVELOPMENT SERVICES DEPARTMENT.
U. THE CONTRACTOR IS RESPONSIBLE FOR ANY CHANGES MADE DURING CONSTRUCTION THAT HAVE NOT BEEN
CITY OF WAUKEE DEVELOPMENT SERVICES DEPARTMENT PRIOR TO CONSTRUCTION.
T. ANY CHANGES PROPOSED TO THE DRAWINGS DURING CONSTRUCTION SHALL BE APPROVED IN WRITING BY THE
PEDESTRIAN FACILITIES.
S. ALL STAKING SHALL BE DONE UNDER THE DIRECTION OF A LICENSED ENGINEER OR LAND SURVEYOR INCLUDING
CONSTRUCTION ACTIVITIES BEGINNING.
R. A PRE-CONSTRUCTION MEETING WITH THE CITY OF WAUKEE WILL BE REQUIRED A MINIMUM OF ONE WEEK PRIOR TO
DISTANCE FROM THE WATER MAIN TO THE STORM SEWER IS AT LEAST TEN FEET.
GREATER. O-RING GASKET JOINTS SHALL BE INSTALLED ON EACH SIDE OF THE CROSSING UNTIL THE NORMAL
SEWER SHALL BE CONSTRUCTED OF REINFORCED CONCRETE WITH A FLEXIBLE O-RING GASKET RATED AT 13 PSI OR
Q. IF STORM SEWER CROSSES ABOVE WATER MAIN OR CROSSES LESS THAN 18" BELOW A WATER MAIN THEN STORM
SERVICES WITH UTILITY SERVICE PROVIDER, CITY OF WAUKEE, AND THE OWNER PRIOR TO CONSTRUCTION.
P. CONTRACTOR TO COORDINATE NATURAL GAS, ELECTRICAL, TELEPHONE AND ANY OTHER FRANCHISE UTILITY
SHALL BE MET BY CONTRACTOR. A COSESCO PERMIT IS REQUIRED FOR THIS PROJECT.
MEASURES ON SITE AT THE TIME OF CONSTRUCTION. GRADING AND SOIL EROSION CONTROL CODE REQUIREMENTS
NECESSARY. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR MAINTAINING ANY EXISTING EROSION CONTROL
O. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING EROSION AND SEDIMENT CONTROL MEASURES AS
SITE WORK.
N. THE ADJUSTMENT OF ANY EXISTING UTILITY APPURTENANCES TO FINAL GRADE IS CONSIDERED INCIDENTAL TO THE
EVENT.
SIDEWALKS CAUSED BY CONSTRUCTION ACTIVITIES AT THE END OF EACH WORK DAY AND PRIOR TO A RAIN
M. THE CONTRACTOR IS RESPONSIBLE FOR CLEANING DIRT AND DEBRIS FROM NEIGHBORING STREETS, DRIVEWAYS, AND
(GUTTER), UNLESS OTHERWISE NOTED.
L. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS SHOWN ARE FINISHED GRADES AND/OR TOP OF PAVING SLAB
GRADES TO MEET SUDAS SPECIFICATIONS SECTION 2010 FOR TOPSOIL.
K. CONTRACTOR TO STRIP AND STOCKPILE TOPSOIL FROM ALL AREAS TO BE CUT OR FILLED. RESPREAD TO FINISH
INTO THE PROJECT TO AN APPROVED OFF-SITE WASTE SITE.
J. CONTRACTOR TO LOAD AND TRANSPORT ALL MATERIALS CONSIDERED TO BE UNDESIRABLE TO BE INCORPORATED
WAUKEE STANDARDS.
ANY CHANGES COMPLETED WITHOUT APPROVAL ARE SUBJECT TO REMOVAL IN ORDER TO MEET THE CITY OF
IMPROVEMENTS PRIOR TO CONSTRUCTION. CONTACT CITY OF WAUKEE FOR APPROVAL OF ANY CHANGES AND THAT
STARTING CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LAYOUT VERIFICATION OF ALL SITE
BETWEEN THIS PLAN AND FIELD CONDITIONS ARE TO BE REPORTED TO THE ARCHITECT/ENGINEER PRIOR TO
THE TIME OF DESIGN. DEVIATIONS MAY BE NECESSARY IN THE FIELD. ANY SUCH CHANGES OR CONFLICTS
I. DIMENSIONS, BUILDING LOCATION, UTILITIES AND GRADING OF THIS SITE ARE BASED ON AVAILABLE INFORMATION AT
ACCORDINGLY ON THE AS-BUILT DOCUMENTS.
H. ALL FIELD TILES ENCOUNTERED DURING CONSTRUCTION SHALL BE RECONNECTED OR REPAIRED AND NOTED
PLANS SHALL GOVERN.
G. IN THE EVENT OF A DISCREPANCY BETWEEN THE QUANTITY ESTIMATES AND THE DETAILED PLANS, THE DETAILED
COMPACT TO 95% MAXIMUM DENSITY.
F. CONSTRUCT MANHOLES AND APPURTENANCES AS WORK PROGRESSES. BACKFILL WITH SUITABLE MATERIAL AND
WEEKEND OR HOLIDAY WORK.
ALSO NOTIFY THE CITY OF WAUKEE PUBLIC WORKS DEPARTMENT AT LEAST 48 HOURS PRIOR TO ANY PLANNED
E. NOTIFY OWNER, ENGINEER, CITY OF WAUKEE AT LEAST 48 HOURS PRIOR TO BEGINNING WORK. CONTRACTOR SHALL
ANTICIPATED LANE CLOSURE.
AND ACTIONS. THE CONTRACTOR SHALL NOTIFY THE CITY OF WAUKEE AT LEAST ONE WEEK PRIOR TO ANY
ROADWAY, FLAGGERS SHALL BE PROVIDED. FLAGGERS SHALL CONFORM TO THE MUTCD IN APPEARANCE, EQUIPMENT
UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). WHEN CONSTRUCTION ACTIVITIES OBSTRUCT PORTIONS OF THE
D. ALL TRAFFIC CONTROL SHALL BE PROVIDED IN ACCORDANCE WITH REQUIREMENTS SET FORTH IN THE MANUAL ON
STRUCTURE.
C. LENGTH OF UTILITIES SHOWN ON PLANS ARE DIMENSIONED FROM CENTERLINE OF STRUCTURE TO CENTERLINE OF
REPORTS PREPARED BY OTHERS.
SPECIFICATIONS FOR PUBLIC IMPROVEMENTS, STATEWIDE URBAN DESIGN AND SPECIFICATIONS AND THE SOILS
B. CONSTRUCTION OF ALL STREET AND UTILITY IMPROVEMENTS SHALL CONFORM TO THE WAUKEE STANDARD
BE REPAIRED TO THE UTILITY OWNER'S SPECIFICATIONS AT THE CONTRACTOR'S EXPENSE.
REMOVAL OR MODIFICATION. ANY DAMAGES TO UTILITY ITEMS NOT SHOWN FOR REMOVAL OR MODIFICATION SHALL
EXACT LOCATION, AND DEPTH OF ALL UTILITIES. PROTECT ALL UTILITY LINES AND STRUCTURES NOT SHOWN FOR
PROVIDERS AS NECESSARY DURING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXISTENCE,
A. NOTIFY UTILITY PROVIDERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES AND COORDINATE WITH UTILITY
BUILDING DESCRIPTION
BUILDING CONSTRUCTION TYPE:
TOTAL = 13,516 SF
LEASE = 3,436 SF
OFFICE = 10,080 SFBUILDING SF:
HEIGHT: 24'-0"
HH
HH
BICYCLE RACK BENCH BENCHBENCH
8" W
8" W8" WST
ST
ST
STST8" SAN9 9
97
10
7
10 10
FUTURE STALLS FUTURE STALLS
ROOM
FIRE RISER
10
T HGAS30' Ingress/Egress Easement
(BOOK 2019, PAGE 21469)
Easement
Storm Sewer75.22'38'
276.70'N0°11'20"E 271.19'M&R276.70'44.24'
15'15'S0°11'20"W 271.19'75,039 SF
LOT 1
PT LOT 2
30' Ingress/Egress Easement
(BOOK 2019, PAGE 21469)
Existing 10' Sanitary Sewer Easement
(BOOK 2019, PAGE 21469)
Existing 10' Public Utility Easement
(BOOK 2019, PAGE 21469)
COVE AT KETTLESTONE PLAT 2
Easement
30' Ingress/Egress
PT LOT 2
48,002 SF
LOT 2
LOT 1(BOOK 2019, PAGE 21469)COVE AT KETTLESTONE PLAT 2(BOOK 2019, PAGE 21469)
Existing 10' Public Utiltiy Easement
21469)
(BOOK 2019, PAGE
Easement
20' Ingress/Egress
80' Temporary Grading Easement
Detention Easement 1"= 120.0504KMMEDCRMM120.050488WAUKEE, IOWA BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= ZARNESONV:\Projects\2020\120.0504.01\CADD\SP_1200504_03DIM.dgn7/22/20205:05:29 PMSnyder1:20Y:\pen\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of
Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS06/23/20RMM6/09/2020ELITE EYE CARE - WAUKEE2REVISED AS PER CITY COMMENTS07/07/20RMM3REVISED AS PER CITY COMMENTS07/22/20RMMC
C
Concrete Sidewalk
F.L.=1055.46 15" CPP W
F.L.=1055.51 12" PVC S
Rim=1057.96
Concrete
12" PVC N
F.L.=1056.77
Concrete Sidewalk
Inv=1038.62 8" PVC W
Inv=1038.72 8" PVC E
Rim=1061.17
SE BISHOP DR
Concrete
Concrete
SE UNIVERSITY AVE
Inv=1040.39 8" PVC W
Inv=1040.49 8" PVC E
Rim=1059.69
CP3
BM1BM2
8" 8" 8" 8"
DIMENSION PLAN CONSTRUCTION NOTES
NO SCALE VARIES1"R
4.5"
7.5"
2"R 6"PCC STANDARD CURB PCC SIDEWALK W/ INTEGRAL CURB
6"
NO SCALE
12"18"
VARIES
SIDEWALK
6
7
4
2 3 height: 0" to 2"
Drop curb
1'-0" min.
Curb opening
18"12"
Driveway width
NO SCALE3
1 DIMENSION PLAN3 35
DETAIL B
2
7Back of curb
1 R
bar
reinforcing
#5 x 36"
1'-0"
TYPICAL SECTION
Curb
Driveway
SidewalkPr
o
pert
y line
TYPE A WITH RADII
as specified
Detail B
Refer to
curb
Back of
8
2
'E' joint
joint
'C' or 'E'
'B' joint
'C' joint
9
10
10
1'-0"
CONCRETE DRIVEWAY, TYPE A
detectable warning panel with Engineer.
Figure 7030.205; verify need for
change requires a curb ramp, comply with
sidewalk through driveway. If elevation
transition from existing sidewalk to
exceeds 2.0%, remove and replace to
If cross slope of adjacent sidewalk panel
passing space.
driveway 5 feet wide to serve as a
construct the sidewalk through the
specified in the contract documents,
maximum cross slope of 2.0%. If
Target cross slope of 1.5% with a
2% toward center of alley.
For alleys, invert the pavement crown
'B' joint is specified.
Provide 'E' joint at back of curb unless
10
9
8
7
6
5
4
3
2
1
8 inches minimum.
Match thickness of adjacent roadway,
pavement.
Center reinforcing bar vertically in the
match thickness of driveway.
Sidewalk thickness through driveway to
minimum.
Commercial and industrial: 7 inches
Residential: 6 inches minimum.
Pavement thickness.
across sidewalk.
of sidewalk. Do not extend raised curb
end of taper/radius or at the front edge
Transition the curb height to 0 inches at
specified in the contract documents.
Commercial and industrial: As
maximum.
Residential: 10 foot minimum,15 foot
Driveway radius (R).
7" PCC PAVEMENT
6" PCC PAVEMENT
4" PCC SIDEWALK 20'0 20
FEET
3
1
3
2
9" PCC PAVEMENT
10.0'15.1'19.0'34.1'25.0' B/BTYP19.0'6.0'5.2'TYP
9.0'
10.0'96.3'70' ROW
MAINTENANCE OF THE SANITARY SEWER.
EXISTING SANITARY SEWER EASEMENT IF PAVEMENT NEEDS TO BE REMOVED FOR
8. THE CITY OF WAUKEE IS NOT RESPONSIBLE FOR PAVEMENT REPLACEMENT WITHING
ARCHITECTURAL PLANS PRIOR TO CONSTRUCTION.
E. SCREEN WALL. COORDINATE EXACT LOCATION AND DIMENSIONS WITH
D. BIKE RACK LOCATION. COORDINATE WITH OWNER.
C. BENCHES. COORDINATE WITH OWNER.
DETAILS.
B. MONUMENT SIGN. BY OTHERS. SEE ARCHITECTURAL AND ELECTRICAL PLANS FOR
A. TRASH ENCLOSURES.
7. SITE AMENITIES, PROVIDE THE FOLLOWING:
WAUKEE, AND OWNER PRIOR TO CONSTRUCTION.
C. COORDINATE RELOCATION OF LIGHT POLE WITH UTILITY PROVIDER, CITY OF
CONSTRUCTION.
COORDINATE WITH THE OWNER ALL ASPECTS SITE LIGHTING PRIOR TO
B.SITE LIGHTING SHOWN IS FOR ILLUSTRATION PURPOSES ONLY. CONTRACTOR TO
ALL ASPECTS OF ELECTRICAL SERVICE.
A.CONTRACTOR TO COORDINATE WITH THE UTILITY OWNER AND PROPERTY OWNER
6. SITE LIGHTING, PROVIDE THE FOLLOWING:
A. PROVIDE VAN ACCESSIBLE PARKING SIGNAGE AS PER ADAAG REQUIREMENTS.
5. SIGNS, PROVIDE THE FOLLOWING:
C. ACCESSIBLE AISLE. 45° STRIPING AT 3' ON CENTER SPACING WHERE SHOWN.
B. PAINTED STATE OF IOWA APPROVED ACCESSIBLE PARKING SYMBOL.
A. 4" WIDE PAINTED PARKING STALL LINES.
4. PAVEMENT MARKINGS, PROVIDE THE FOLLOWING:
H. TAPER TO NO CURB IN 6'.
SPECIFICATIONS.
G. 9" DEPTH PCC ENTRANCE APPROACH TO BE CONSTRUCTED AS PER STANDARD
MEETS VEHICULAR TRAFFIC.
DETECTABLE WARNING SYSTEM AT RAMPS WHERE PEDESTRIAN TRAFFIC
PEDESTRIAN RAMP WITH A MAXIMUM SLOPE OF 8.33%. PROVIDE F.
E. INTEGRAL CURB.
D. STANDARD CURB.
C. PCC SIDEWALKS, 4" DEPTH PAVEMENT.
COMPACTED TO 95% STANDARD PROCTOR DENSITY.
B. PCC DRIVES, 7" DEPTH PAVEMENT ON 12" DEPTH PREPARED SUBGRADE
COMPACTED TO 95% STANDARD PROCTOR DENSITY.
A. PCC PARKING, 6" DEPTH PAVEMENT ON 12" DEPTH PREPARED SUBGRADE
3. PAVEMENTS, PROVIDE THE FOLLOWING:
D. REMOVE AND DISPOSE OF EXISTING STORM SEWER.
UTILIY PROVIDER PRIOR TO CONSTRUCTION.
C. REMOVE AND RELOCATE COMMUNICATION BOX. COORDINATE WITH OWNER AND
B. SAWCUT FULL DEPTH PCC, REMOVE AND DISPOSE OF EXISTING PCC.
A. GRIND CURB.
2. DEMOLITION, REMOVE THE FOLLOWING:
OWNER'S SPECIFICATION.
CONTRACTORS EXPENSE WITH WORK BEING PREFORMED TO THE UTILITY
NOT SCHEDULED FOR MODIFICATION OR DEMOLITION SHALL BE REMEDIED AT THE
B. PROTECT EXISTING UTILITIES, ANY DAMAGE TO THE EXISTING UTILITIES THAT ARE
A. PAVEMENTS TO REMAIN.
1. EXISTING FEATURES, PROTECT THE FOLLOWING:
15.0'R
15.0'
R
5.0'R15.0'R 15.0'R5.0'R
25.0' B/B
5.1'20.0'
TYP
9.0'
TYP
9.0'
9.0'9.0'9.0'9.0'9.0'9.0'15.0'15.0'5.0'
11.1'
7.5'8.5'5.0'11.8'B/B
25.0'
19.0' TYP
6.0'
6.9'9.0'6.0'19.0' TYP25.0' B/B19.0' TYP7.0'7.0'6.0'6.0'10.0'
10.0'
5.5'
6.0'5.0'5.0'5.0'5.0'6.0'
5.0'R13.6'
R
5.0'5.5'18.5'13.5'5.0'
19.0'15.0'R5 .0 'R77.0'
25.0' B/B
2
5.0'R
25.0'R55.1'12.0'70.0' ROW31.0' B/B37.2'25.0'120.0' ROW14.4'39.7'23.1'11.7'14.3'20.1'25.2'20.1'14.3'39.2'112.8'24.9'25.3'4.0'15.0'1A
1A
1A 1A
1A
1A
1A
1A
1B
1B
1B
1B1B
1B
1B
1B
1B
1B
1B
2A2A
2A
2A
2B 3B
3A 3A
3A
3A
3A
3A
3A
3B
3B 3B
3B
3B
3C
3C 3C 3C 3C
3C
3C
3C3C
3D
3D
3D
3D
3D
3D3D
3D
3E
3E
3E
3E
3E3E
3F
3F
3F
3F
3F
3F
3F
3F
4A
TYP
4A
TYP
4A
TYP
TYP
4A
TYP
4A
4C
4B
4B4C
7A
5A
5A
5A
7D
3F
7C
2D
3D 3D
2C
2D
6C
3G
9" PCC
7" PCC
7" PCC
7" PCC
7" PCC
7" PCC7" PCC
6" PCC
6" PCC
6" PCC
6" PCC
6" PCC
6" PCC
6" PCC
3H
PATIO
DRIVEWAY (7030.101)
SUDAS TYPE A
7B
HH
HH
BICYCLE RACK BENCH BENCHBENCH
8" W
8" W8" W9 9
97
10
7
10 10
FUTURE STALLS FUTURE STALLS
ROOM
FIRE RISER
10
T HGASAL=25.16
30' Ingress/Egress Easement
(BOOK 2019, PAGE 21469)
Easement
Storm Sewer75.22'38'
276.70'N0°11'20"E 271.19'M&R276.70'44.24'
15'15'S0°11'20"W 271.19'75,039 SF
LOT 1
PT LOT 2
30' Ingress/Egress Easement
(BOOK 2019, PAGE 21469)
Existing 10' Sanitary Sewer Easement
(BOOK 2019, PAGE 21469)
Existing 10' Public Utility Easement
(BOOK 2019, PAGE 21469)
COVE AT KETTLESTONE PLAT 2
Easement
30' Ingress/Egress
PT LOT 2
48,002 SF
LOT 2
LOT 1(BOOK 2019, PAGE 21469)COVE AT KETTLESTONE PLAT 2(BOOK 2019, PAGE 21469)
Existing 10' Public Utiltiy Easement
21469)
(BOOK 2019, PAGE
Easement
20' Ingress/Egress
172.33'
AL=91
.98
'
C
-4
80' Temporary Grading Easement
Detention Easement 1"= 120.0504KMMEDCRMM120.050488WAUKEE, IOWA BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= ZARNESONV:\Projects\2020\120.0504.01\CADD\SP_1200504_04UTL.dgn7/22/20205:05:30 PMSnyder1:20Y:\pen\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of
Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS06/23/20RMM6/09/2020ELITE EYE CARE - WAUKEE2REVISED AS PER CITY COMMENTS07/07/20RMM3REVISED AS PER CITY COMMENTS07/22/20RMMC
C
Concrete Sidewalk
F.L.=1055.46 15" CPP W
F.L.=1055.51 12" PVC S
Rim=1057.96
Concrete
12" PVC N
F.L.=1056.77
Concrete Sidewalk
Inv=1038.62 8" PVC W
Inv=1038.72 8" PVC E
Rim=1061.17
SE BISHOP DR
Concrete
Concrete
SE UNIVERSITY AVE
Inv=1040.39 8" PVC W
Inv=1040.49 8" PVC E
Rim=1059.69
CP3
8" 8" 8" 8"
1056
1057105810591060 10601060106010601 061
1061
1061
10611061 10611061
106110611061
1062
1062 1062 106210621062
106210621062 20'0 20
FEET
4 UTILITY PLAN4UTILITY PLAN CONSTRUCTION NOTES
TESTED AND DECHLORINATED.
E. ALL WATERMAIN SHALL BE PRESSURE AND BACTERIA
D. ALL SANITARY MANHOLES TO BE VACUUM TESTED.
MANHOLES SHALL BE VACUUM TESTED.
SHALL BE PROVIDED TO THE CITY OF WAUKEE. ALL SANITARY SEWER
ALL CLEANING AND TELEVISING. COPIES OF THE REPORT AND VIDEO
TELEVISED PRIOR TO PAVING. THE CITY OF WAUKEE SHALL WITNESS
C. ALL SANITARY SEWER AND STORM SEWER SHALL BE CLEANED AND
DEPARTMENT.
TIE-INS SHALL BE WITNESSED BY THE CITY OF WAUKEE ENGINEERING
SPECIFICATION FOR PUBLIC IMPROVEMENTS AND ANY TESTING OR
B. ALL UTILITIES SHALL BE TESTED TO THE CITY OF WAUKEE STANDARD
CONNECTING TO ANY PUBLIC UTILITY.
A. NOTIFY THE CITY OF WAUKEE AT LEAST 48 HRS PRIOR TO
GENERAL CONSTRUCTION NOTES
NO SCALE4
1
FL=1058.37 (OUT W)
RIM=1061.12
ST-4, TYPE SW-511
128LF of 15"RCP @ 0.5%
FL=1057.63 (OUT NW)
FL=1057.73 (IN E)
RIM=1060.84
ST-5, TYPE SW-511
146LF of 15"RCP @ 0.5%FL=1056.33 (OUT SW)
FL=1056.43 (IN E)
RIM=1059.85
ST-3, TYPE SW-511
FL=1056.06
GUARD
FOOTING & APRON
ST-3A, 18" FES W/
INV=1039.51
2C
TP=1055.22(SAN)
BP=1058.13(ST)
TP=1055.12(WAT)
BP=1058.12(ST)
2B
FL=1055.51
INTAKE
CONNECT TO EX.
54
LF of 15"
R
CP @ 0.5
%6. TRANSFORMER LOCATION. COORDINATE WITH OWNER AND FRANCHISE UTILITY PROVIDER.
SEPARATION.
5. CRITICAL CROSSING. CONTRACTOR TO VERIFY ALL CROSSINGS AND PROVIDE 18" MINIMUM
COORDINATE UTILITY CONNECTIONS ACCORDINGLY.
MECHANICAL PLANS FOR INTERIOR UTILITY ROUTING, METERS, DESIGN INFORMATION AND
UTILITY SERVICE PROVIDER PRIOR TO CONSTRUCTION. SEE ARCHITECTURAL AND
4. COORDINATE NATURAL GAS AND ELECTRICAL SERVICES AND METER LOCATION WITH
G. 2" VALVE
F. 6" VALVE
E. REMOTE FIRE DEPARTMENT CONNECTION. COORDINATE WITH MECHANICAL PLANS.
CONSTRUCTION.
D. CONNECT TO EXISTING. CONTRACTOR TO VERIFY LOCATION AND DEPTH PROIR TO
MECHANICAL PLANS PRIOR TO CONSTRUCTION.
C. BUILDING WATER SERVICE CONNECTION. VERIFY LOCATION AND DEPTH WITH
B. 2" DOMESTIC WATER SERVICE
A. 8" WATER SERVICE LINE.
3. WATER SERVICES, PROVIDE THE FOLLOWING:
ELEVATION PRIOR TO CONSTRUCTION. USE 1:1 RISER AS NECESSARY.
D. CONNECT TO EXISTING 8" SANITARY SEWER. CONTRACTOR TO VERIFY LOCATION AND
C. SANITARY SEWER CLEANOUT.
MECHANICAL PLANS PRIOR TO CONSTRUCTION.
B. CONNECT TO BUILDING SANITARY SERVICE. VERIFY LOCATION AND ELEVATION WITH
A. 6" SANITARY SEWER SERVICE LINE @ MINIMUM 1.0%
2. SANITARY SEWER SERVICES; PROVIDE THE FOLLOWING:
SPECIFICATION.
CONTRACTORS EXPENSE WITH WORK BEING PERFORMED TO THE UTILITY OWNER'S
SCHEDULED FOR MODIFICATION OR DEMOLITION SHALL BE REMEDIED AT THE
A. PROTECT EXISTING UTILITES, ANY DAMAGE TO THE EXISTING UTILITIES THAT ARE NOT
1. EXISTING FEATURES, PROTECT THE FOLLOWING:
INV=1055.75
@ 2.0%6" PVC97 LF OF3F3G
12" STORM SEWER
REMOVE EXISTING
3B
3D
3C
FFE=1062.25
FL=1057.36
GUARD
FOOTING & APRON
ST-5A, 15" FES W/
EXISTING 150' R HYDRANT COVERAGE
EXISTING 150' R HYDRANT COVERAGEPROPOSED 150' R HYDRANT COVERAGECONCRETE FOOTING
3"
1'-8"3'-6"6"
RESTRICTOR PLATE
FOR SIZES
SECTION, SEE PLAN
RCP FLARED END
5/8" HOLES
SECTION VIEW
END VIEW 3'-6"VARIES TO MATCH
WIDTH OF END SECTION
FOOTING
CONCRETE
1/2" BOLTS
HOLES FOR
DRILL 5/8"
ORIFICE PLATE DETAIL
ORIFICE PLATE.
1/4" STAINLESS STEEL
ORIFICE PLATE.
BOLT. WELD TO
WITH 5/8 " HOLE FOR 1/2"
3" x 3" x 3" x 1/4" ANGLE89LF of 12"RCP @ 0.45% TRENCHLESS METHOD
INSTALLED VIA
WATER SERVICE TO BE
TP=1040.19(EX SAN)
BP=1055.12(WAT)
ST-5=4-13/16" Dia.
ST-5=4-13/16" Dia.
3E
FL=1057.61 (OUT NW)
RIM=1060.25
ST-1, TYPE SW-511
70LF of 15"RCP @ 0.5
%FL=1057.16 (OUT W)
FL=1057.26 (IN SE)
RIM=1060.58
ST-2, TYPE SW-511
55LF of 18"RCP @ 0.5%FL=1055.91
ORIFICE PLATE
GUARD & 5-1/8""
FOOTING & APRON
ST-6, 12" FES W/
4
(4' x 5' x 1.5')
RIP-RAP
CLASS-D
10 TONS OF
(4' x 5' x 1.5')
RIP-RAP
CLASS-D
10 TONS OF
2D
2A
3A
55
1A
1A
5
6
4
4
HH
HH
BICYCLE RACK BENCH BENCHBENCH
8" W
8" W8" WST
ST
ST
STST8" SAN9 9
97
10
7
10 10
FUTURE STALLS FUTURE STALLS
ROOM
FIRE RISER
10
HAL=25.16
30' Ingress/Egress Easement
(BOOK 2019, PAGE 21469)
Easement
Storm Sewer75.22'38'
276.70'N0°11'20"E 271.19'M&R276.70'44.24'
15'15'S0°11'20"W 271.19'75,039 SF
LOT 1
PT LOT 2
30' Ingress/Egress Easement
(BOOK 2019, PAGE 21469)
Existing 10' Sanitary Sewer Easement
(BOOK 2019, PAGE 21469)
Existing 10' Public Utility Easement
(BOOK 2019, PAGE 21469)
COVE AT KETTLESTONE PLAT 2
Easement
30' Ingress/Egress
PT LOT 2
48,002 SF
LOT 2
LOT 1(BOOK 2019, PAGE 21469)COVE AT KETTLESTONE PLAT 2(BOOK 2019, PAGE 21469)
Existing 10' Public Utiltiy Easement
21469)
(BOOK 2019, PAGE
Easement
20' Ingress/Egress
172.33'
AL=91
.98
'
C
-4
80' Temporary Grading Easement
Detention Easement 1"= 120.0504KMMEDCRMM120.050488WAUKEE, IOWA BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= ZARNESONV:\Projects\2020\120.0504.01\CADD\SP_1200504_05GRA.dgn7/22/20205:05:31 PMSnyder1:20Y:\pen\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of
Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS06/23/20RMM6/09/2020ELITE EYE CARE - WAUKEE2REVISED AS PER CITY COMMENTS07/07/20RMM3REVISED AS PER CITY COMMENTS07/22/20RMMC
C
Concrete Sidewalk
F.L.=1055.46 15" CPP W
F.L.=1055.51 12" PVC S
Rim=1057.96
Concrete
12" PVC N
F.L.=1056.77
Concrete Sidewalk
Inv=1038.62 8" PVC W
Inv=1038.72 8" PVC E
Rim=1061.17
SE BISHOP DR
Concrete
Concrete
SE UNIVERSITY AVE
Inv=1040.39 8" PVC W
Inv=1040.49 8" PVC E
Rim=1059.69
CP3
BM2
8" 8" 8" 8"
1057 1058105810581059
1059 1059105910591059106010601060
10601060106010601060106010611061
1061
1061 10611062
1061.41
1060.36 1060.41(1059.46)
(1059.37)
1056
10571058(1058.95)1059(1059.30)(1059.54)
1059.75
1059.79
1059.851060 10601060106010601060.53TC)
(1060.03G
1060.051061.07
1060.59TC
1060.09G
1060.09
1060.17
1060.21
(1060.24)
(1060.32)
1060.82TC
1060.32G
1060.381060.38
1060.41
OVERFLOW
1060.41
1060.42
1060.93TC)
(1060.43G
1060.47
1060.99TC
1060.49G
1060.95G
1061.06TC
1060.56G
1060.58
1061.11TC
1060.61G
1060.631060.63
(1060.65)
1060.751061.29TC
1060.79G
(1060.80)
(1060.81)1059.95
1060.83
1061.45TC
1060.95G1060.85
1061.36TC
1060.86G
1060.88
1060.89
1060.91
1060.95
1060.471060.971061
1061
1061
10611061 10611061
1061.001061 10611061
1061.01
1060.42
1061.06
1061.57TC
1061.07G
1061.60TC
1061.10G
HP
1061.10
1061.12
1061.63TC
1061.13G
1061.13
1061.15
1061.20
1061.70TC
1061.20G
1061.72TC
1061.22G1061.221061.78TC
1061.28G
1061.28 1061.31
1061.85TC
1061.35G
1061.85TC
1061.35G1061.35 1061.41
1061.41
1061.41
1061.41
1061.41
1061.41
1061.41
1061.41
1061.41
1061.41
1061.42
1061.43
1061.95TC
1061.45G
1061.98TC
1061.48G
1061.48
1061.99TC
1061.49G
1061.01
1061.51
1061.51
1061.511061.411062.08TC1061.58G1062.09TC
1061.59G
1061.92TC
1061.42G
1060.921060.83
1062.13TC
1061.63G
1061.641061.651062.20TC
1061.70G
1062.20TC
1061.70G1062.21TC1061.71G
1062.21TC
1061.71G
1061.721061.75
1062.36TC
1061.76G
1061.80
1062.31TC
1061.81G
1061.83
1060.84
1061.85TC1061.35G
1062.40TC
1061.90G
1062.45TC
1061.95G
1062
1062 1062 106210621062
1062106210621062.25FFE1062.00FG
1062.53TC
1062.03G
1062.09TC
1061.59G
1062.65TC
1062.15G
1062.21TC1061.71G
1062.25
1062.251062.25
1062.95TC
1062.45G 20'0 20
FEET
5 5GRADING PLAN GENERAL NOTES
GRADING PLANFFE=1062.25
ELEVATION=1060.35
100-YEAR PONDING
ELEVATION=1061.02
100-YR PONDING
ELEVATION=1061.33
100-YR PONDING
ELEVATION=1060.79
100-YR PONDING
ELEVATION=1060.07
100-YR PONDING
W/15" MIN. OVERLAP
4-#4 LONGITUDINAL REBAR
CLEARANCE2"2% M
IN
.SLOPE
6"
NOTES
SUBGRADE
6" COMPACTED 6"1"2% MIN.SLOPE
5'-0" O.C. (3'-6" LONG)
#4 TRAVERSE REBAR @
6. TAPER WIDTH TO MATCH FLARED END SECTION WIDTH AS NECESSARY.
5. REBAR SHALL BE EPOXY COATED STEEL AS PER SUDAS.
4. CURING AS SPECIFIED FOR CONCRETE PAVEMENT IN SUDAS.
3. FINISH SHALL CONFORM TO SUDAS FOR SIDEWALKS AND PROVIDE FINAL BROOM FINISH.
CONSTRUCTION. PLACE TOPSOIL OVER ALL AREAS DISTURBED.
2. CONCRETE WILL HAVE THE MIX DESIGN AS SHOWN FOR STREET PAVEMENT IN THE
ROADSTONE BASE.
1. SUBGRADE SHALL CONSIST OF A FIRM UNYIELDING CLAY (CL OR CH) OR CLASS "A"
NO SCALE 4"4'-0"
PCC CUNETTE
5
12.0%MIN2.0%MIN2.0%MIN2.0%MIN2.0%MIN
2.0%MIN
1061.35
ST-4 OVERFLOW
1061.51
ST-3 OVERFLOW
1061.06
ST-1 OVERFLOW1060.59ST-2 OVERFLOW2.0%MIN
4:14:1 4:14:14:12.0%MIN2.0%MIN1061.85TC
1061.35G
G. SLOPES OF ALL UNPAVED AREAS TO BE 2.0% MINIMUM.
A RAIN EVENT.
CONSTRUCTION ACTIVITIES BY THE END OF THE WORK DAY AND PRIOR TO
FROM STREETS, DRIVEWAYS, AND SIDEWALKS CAUSED BY
F. THE CONTRACTOR IS RESPONSIBLE FOR CLEANING DIRT AND DEBRIS
CUT OR FILLED. RESPREAD TO MINIMUM 8" DEPTH TO FINISH GRADES.
E. CONTRACTOR TO STRIP AND STOCKPILE TOPSOIL FROM ALL AREAS TO BE
SECTION.
STRUCTURE TO CENTER OF STRUCTURE AND INCLUDE FLARED END
D. ALL STORM SEWER PIPE LENGTHS ARE MEASURED FROM CENTER OF
NOTED.
GRADES AND/OR TOP OF PAVING SLAB (GUTTER), UNLESS OTHERWISE
C. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS SHOWN ARE FINISHED
RELOCATIONS WITH UTILITY PROVIDER.
CONTRACTOR'S EXPENSE. COORDINATE ANY UTILITY
CONTRACTOR'S CARELESSNESS SHALL BE CORRECTED AT THE
AND SERVICES DURING CONSTRUCTION. ANY DAMAGE DUE TO THE
LOCATION AND DEPTH OF ALL UTILITIES. AVOID DAMAGE TO UTILITIES
CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXISTENCE, EXACT
B. NOTIFY UTILITY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION.
LOCATION INDICATED.
DOES NOT WARRANT THAT THE UTILITIES SHOWN ARE IN THE EXACT
IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEY FURTHER
GUARANTEE THAT THE UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES
INFORMATION AND/OR RECORDS OBTAINED. THE SURVEYOR MAKES NO
THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY
A. UTILITY WARNING:
ELEVATION=1060.39
100-YR PONDING
ELEVATION=1058.03
100-YR PONDING 1059.50EX-ST OVERFLOW
HH
HH
BICYCLE RACK BENCH BENCHBENCH
8" W
8" W8" WST
ST
ST
STST8" SAN9 9
97
10
7
10 10
FUTURE STALLS FUTURE STALLS
ROOM
FIRE RISER
10
H30' Ingress/Egress Easement
(BOOK 2019, PAGE 21469)
Easement
Storm Sewer75.22'38'
276.70'N0°11'20"E 271.19'M&R276.70'44.24'
15'15'S0°11'20"W 271.19'75,039 SF
LOT 1
PT LOT 2
30' Ingress/Egress Easement
(BOOK 2019, PAGE 21469)
Existing 10' Sanitary Sewer Easement
(BOOK 2019, PAGE 21469)
Existing 10' Public Utility Easement
(BOOK 2019, PAGE 21469)
COVE AT KETTLESTONE PLAT 2
Easement
30' Ingress/Egress
PT LOT 2
48,002 SF
LOT 2
LOT 1(BOOK 2019, PAGE 21469)COVE AT KETTLESTONE PLAT 2(BOOK 2019, PAGE 21469)
Existing 10' Public Utiltiy Easement
21469)
(BOOK 2019, PAGE
Easement
20' Ingress/Egress
172.33'
80' Temporary Grading Easement
Detention Easement 1"= 120.0504KMMEDCRMM120.050488WAUKEE, IOWA BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= ZARNESONV:\Projects\2020\120.0504.01\CADD\SP_1200504_06ERO.dgn7/22/20205:05:32 PMSnyder1:20Y:\pen\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of
Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS06/23/20RMM6/09/2020ELITE EYE CARE - WAUKEE2REVISED AS PER CITY COMMENTS07/07/20RMM3REVISED AS PER CITY COMMENTS07/22/20RMMC
C
Concrete Sidewalk
F.L.=1055.46 15" CPP W
F.L.=1055.51 12" PVC S
Rim=1057.96
Concrete
12" PVC N
F.L.=1056.77
Concrete Sidewalk
Inv=1038.62 8" PVC W
Inv=1038.72 8" PVC E
Rim=1061.17
SE BISHOP DR
Concrete
Concrete
SE UNIVERSITY AVE
Inv=1040.39 8" PVC W
Inv=1040.49 8" PVC E
Rim=1059.69
CP3
BM1BM2
8" 8" 8" 8"
1057
105810581059
10591059
10591059106010601060
10601060106010601060106010611061
1061
1061 10611062
1056
1057105810591060 10601060106010601061
1061
1061
10611061 10611061
106110611061
1062
1062 1062 106210621062
106210621062 20'0 20
FEET 66 EROSION AND SEDIMENT CONTROL PLANSTORMWATER MANAGEMENT QUANTITIES
ATTACHMENT TO POST
Fabric
Post
cable ties
Wire or 5
TYPICAL SILT FENCE DITCH CHECK
F
o
resl
opeVariable (20' for a normal 10' wide ditch.)
(5'-0" max.)
Post spacing
(5'-0" max.)
Post spacing
4
5
1
3
Backslope 902
904
906
908
910
TYPICAL SILT FENCE INSTALLATION ON LONGITUDINAL SLOPES
individual section of silt fence
Install "J-hook" at each end of an
ground contour
Install parallel to
(Plan View)
(600' if slope is flatter than 5%)
200' max. length per section
documents or as directed by the Jurisdictional Engineer.
Section 9040, 3.07 and at locations shown in the contract
Install silt fence according to the requirements of
GENERAL NOTES:
1
2
3
4
5
Insert 12 in. of fabric a minimum of 6 in. deep
(fabric may be folded below the ground line)
Compact ground by driving along each side of
the silt fence as required to sufficiently
secure the fabric in the trench to prevent
pullout and flow under the fence.
In ditches, extend silt fence up side slope so
the bottom elevation at the end of the fence is
a minimum of 2 in. higher than the top of the
fence in the low point of the ditch.
Steel posts to be embedded 20 in. unless
otherwise allowed by the Jurisdictional
Engineer.
Secure top of engineering fabric to steel posts
using wire or plastic ties (50 lb. min.). See
details of "Attachment to Posts."
TYPICAL SILT FENCE INSTALLATION ON LONGITUDINAL SLOPES
Ground line
Fabric
Flow
4'-0" minimum
'T' steel fence post
(Profile View)
4
1
1
2
See plans for spacing
NO SCALE
SILT FENCE DETAIL
Ground line
Fabric
1
5
4
or as required to adequately support fence
Reduce post spacing to 5'-0" at water concentration areas,
8'-0"spacing
24"DETAILS OF SILT FENCE ON LONGITUDINAL SLOPES36"6
1
ENTRANCE
STABILIZED CONSTRUCTION
PROPERTY OWNER)
(COORDINATE WITH
STAGING AREA
LOCATION WITH PROPERTY OWNER)
(COORDINATE SIZE AND
LOCATION
APPROXIMATE STOCKPILE
FFE=1062.25
2.09 AC
DISTURBED AREA
WASHOUT
CONCRETE
Q=1.41 CFS
TO WALNUT CREEK
EXISTING STORM SEWER
ULTIMATE DISCHARGE TO
2.09 ACDISTURBED AREA
0.29 ACSOD
0.17 ACDETENTION BASIN SEEDING
0.13 ACSUDAS TYPE 4 SEEDING, FERTILIZING & MULCHING
9 EASEDIMENT BASKETS
988 LFSILT FENCE
BASKET
SEDIMENT
BASKET
SEDIMENT
BASKET
SEDIMENT
BASKET
SEDIMENT
BASKET
SEDIMENT
BASKET
SEDIMENT
BASKET
SEDIMENT
BASKET
SEDIMENT
BASKET
SEDIMENT
BASKET
SEDIMENT
BASKET
SEDIMENT
BASKET
SEDIMENT
BASKET
SEDIMENT
(TYP.)
SILT FENCE
BICYCLE RACK BENCH BENCHBENCH
10 1"= 120.0504KMMEDCRMM120.050488WAUKEE, IOWA BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= ZARNESONV:\Projects\2020\120.0504.01\CADD\SP_1200504_07DTL.dgn7/22/20205:05:33 PMSnyder1:10Y:\pen\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of
Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS06/23/20RMM6/09/2020ELITE EYE CARE - WAUKEE2REVISED AS PER CITY COMMENTS07/07/20RMM3REVISED AS PER CITY COMMENTS07/22/20RMM10
7
10
9H BICYCLE RACK BENCH BENCHBENCH
9 9
97
10
7
10 10
FUTURE STALLS FUTURE STALLS
ROOM
FIRE RISER
10 77 SIDEWALK RAMP DETAILS10'SE UNIVERSITY AVE
7
1
SCALE: 1"=10'
SIDEWALK RAMP AREA 1 DETAIL
7
2
SCALE: 1"=10'
SIDEWALK RAMP AREA 2 DETAIL
7
3
SCALE: 1"=10'
SIDEWALK RAMP AREA 3 DETAIL
7
4
SCALE: 1"=10'
SIDEWALK RAMP AREA 4 DETAIL
7
6
SCALE: 1"=50'
SITE MAP DETAIL
RAMP AREA 3
RAMP AREA 4
RAMP AREA 2
RAMP AREA 1
RAMP AREA 5
7
5
SCALE: 1"=10'
SIDEWALK RAMP AREA 5 DETAIL
1060.36
1060.41
1060.45
1060.41
1060.09
1060.051060.911061.001061.091061.181061.60TC
1061.10G
1061.95TC
1061.45G
1061.75
1062.05
1061.19 1061.28
1061.29 1061.38
1061.78TC
1061.28G
1059.75
1059.79
1060.14
1060.20
1060.14
1060.09
(1059.54)(1059.30)(1059.42)1061.421061.311061.85
1061.85
1061.78
1061.781061.061060.971061.511061.511061.571061.57
1061.75
1061.67
1061.62
1061.671061.041061.071061.011060.981060.471060.421061.99TC
1061.49G
1061.63TC
1061.13G
1060.83
1060.92
1060.74
1061.01
1061.20
1061.20
1061.30
1061.30
1061.90TC
1061.40G
1062.00
1061.95 1061.85TC
1061.35G 1061.651061.721062.191062.191062.251062.251061.511061.431061.83
1061.75 1061.701061.751061.591061.591061.651061.651061.65 1061.591061.591061.651061.411061.511061.351061.281061.46 1061.46 1061.69
1061.00
1061.52 1061.70TC
1061.20G
1061.691.23%2.46%1.33%
0.00%1.20%1.83%6.66%8.30%0.00%1.40%1.23%0.00%2.77%1.66%1.20%
1.16%8.30%7.23%0.00%1.20%1.50%6.92%8.30%0.00%1.20%8.00%
8.00%0.80%1.20%0.80%0.80%1.20%
0.80%0.67%0.83%1.00%
4.37%0.76%5.47%0.76%4.99%
5.94%1.20%1.00%1.20%
1.00%0.00%1.67%
1.67%
1.47%
1.79%
1.95%
3.47%
6.50%
6.50%1.67%1.67%1.67%1.26%1.42%4.56%
4.56%1.67%3.00%1.83%1.16%
0.00%1.20%0.00%
0.00%1.40%0.00%1.20%1.20%0.00%0.00%1.20%0.00%1.67%3.03%1.00%2.41%1060.521060.491061.45TC
1060.95G
1059.94
1059.89
0.16%1061.581061.57 1.66%1061.241060.141.0%1.0%1.0%1.11%1.0%
1.0%1.0%1.67%8.0%8.0%7.2%7.2%1.0%1.0%1.0%7.18%
8.23%
HH
HH
BICYCLE RACK BENCH BENCHBENCH
8" W
8" W8" WST
ST
ST
STST8" SAN9 9
97
10
7
10 10
FUTURE STALLS FUTURE STALLS
ROOM
FIRE RISER
10
H30' Ingress/Egress Easement
(BOOK 2019, PAGE 21469)
Easement
Storm Sewer75.22'38'
15'15'
75,039 SF
LOT 1
30' Ingress/Egress Easement
(BOOK 2019, PAGE 21469)
Existing 10' Sanitary Sewer Easement
(BOOK 2019, PAGE 21469)
Existing 10' Public Utility Easement
Easement
30' Ingress/Egress
48,002 SF
LOT 2
(BOOK 2019, PAGE 21469)
Existing 10' Public Utiltiy Easement
21469)
(BOOK 2019, PAGE
Easement
20' Ingress/Egress
80' Temporary Grading Easement
Detention Easement 1"= 120.0504KMMEDCRMM120.050488WAUKEE, IOWA BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= ZARNESONV:\Projects\2020\120.0504.01\CADD\SP_1200504_08LND.dgn7/22/20205:05:36 PMSnyder1:20Y:\pen\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of
Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS06/23/20RMM6/09/2020ELITE EYE CARE - WAUKEE2REVISED AS PER CITY COMMENTS07/07/20RMM3REVISED AS PER CITY COMMENTS07/22/20RMMC
C
CP3
SE UNIVERSITY AVE
SE BISHOP DR
Concrete
Concrete Sidewalk
Concrete
Concrete Sidewalk
Concrete
1057
1058105810591059
10591059106010601060
10601060106010601060106010611061
1061
1061 10611062
1056
1057105810591060 1060106010601 061
1061
1061
10611061 10611061
106110611061
1062
1062 1062 106210621062
106210621062 20'0 20
FEET
8 8PLANTING PLANPLANTING PLAN GENERAL NOTES
LANDSCAPE REQUIREMENTS AND CALCULATIONS
BOTANICAL NAMEKEY
SHRUBSSIZE COMMENTS
B&B
AG AUTUMN BRILLANCE SERVICEBERRYAmelanchier x grandiflora 'Autumn Brilliance'
B&B
B&B
PLANT SCHEDULE
CONT. (6' O.C.)36" Ht.
COMMON NAME
TREES18" Ht.
24" Ht.
AT
GB
TREESUNDERSTORYPhysocarpus opulifolius 'Donna May'LITTLE DEVIL NINEBARK
VD
SB
Taxus x media 'Taunton'TAUNTON YEW
Spiraea betulifolia 'Tor'TOR BIRCHLEAF SPIREA
Acer tataricum 'Hot Wings'
GT Gleditisia triacanthos var. inermis 'Skyline'B&B
UL
PRINCETON SENTRY GINKGOGinkgo biloba 'Princeton Sentry'
HOT WINGS TATARIAN MAPLE
MS
18" Ht.
24" Ht.
Hemerocallis 'Royal Occasion'ROYAL OCCASION DAYLILY
18" Ht.
B&B
B&B
B&B
DECIDUOUS ORNAMENTAL TREES SHALL BE A MINIMUM OF 6' IN HEIGHT.
EVERGREEN OVERSTORY TREES SHALL BE A MINIMUM OF 6' IN HEIGHT.
DECIDUOUS OVERSTORY TREES SHALL BE A MINIMUM OF 8' IN HEIGHT.
MINIMUM HEIGHT REQUIREMENTS :
276 LF/40 LF = 6.9 STREET TREES REQUIRED (7 STREET TREES PROVIDED)
1 OVERSTORY TREE PER 40 LF OF FRONTAGE
SE BISHOP DR. :
276 LF/40 LF = 6.9 STREET TREES REQUIRED (8 STREET TREES PROVIDED)
1 OVERSTORY TREE PER 40 LF OF FRONTAGE
SE UNIVERSITY AVE. :
STREET TREE REQUIREMENT:
THERE ARE NO BUFFER REQUIREMENTS.
BUFFER REQUIREMENT:
(6 TREES PROVIDED)
PARKING LOT ISLANDS SHALL HAVE A MINIMUM OF 1 OVERSTORY TREE.
OFF-STREET PARKING AREAS:
FOUNDATION PLANTINGS ARE REQUIRED AT THE BASE OF ALL BUILDINGS
FOUNDATION PLANTINGS:
2 SHRUBS x 11.256 PU'S = 22.51 REQUIRED (115 SHRUBS PROVIDED)
0.5 UNDERSTORY TREE x 11.256 PU'S = 5.63 REQUIRED (6 UNDERSTORY TREES PROVIDED)
1 OVERSTORY TREE x 11.256 PU'S = 11.25 REQUIRED (12 OVERSTORY TREES PROVIDED)
11,256/1,000 = 11.256 PLANT UNITS (PU'S)
18 TREES REQUIRED X 25% = 4.5 EVERGREEN TREES REQUIRED (5 PROVIDED)
MINIMUM OF 25% OF TOTAL REQUIRED TREES SHALL BE EVERGREEN.
1.0 OVERSTORY TREES, 0.5 UNDERSTORY TREES, AND 2.0 SHRUBS PER 1,000 SF OF REQUIRED OPEN SPACE.
75,039 SF (TOTAL LOT) x 15% = 11,255.85 SF REQUIRED (29,257 SF PROVIDED)
15% OPEN SPACE REQUIRED
(LANDSCAPE CALCULATIONS BASED UPON CITY OF WAUKEE ZONING CODE REQUIREMENTS AND THE KETTLESTONE DESIGN GUIDELINES PUD)
18" Ht.Salvia nemorosa 'Caradonna'CARADONNA SALVIA
Ulmus x 'Patriot'
CO PRAIRIE PRIDE HACKBERRY B&BCeltis occidentalis 'Prairie Pride'
PINK SPIRES CRABAPPLE
8' HT.B&B
BLUES FESTIVAL ST. JOHN'S WORT
SKYLINE HONEYLOCUST
1 1/2"
1 1/2"
1 1/2"
1 1/2"
8' HT.
Viburnum dentatum 'Rastzam'RASPBERRY TART VIBURNUM
CONT. (4' O.C.)
CONT. (3' O.C.)
CONT. (3' O.C.)
HK
PO
Hypericum kalmianum 'Blues Festival'
24" Ht.
18" Ht.
CONT. (3' O.C.)
CA CONT. (3' O.C.)& GRASSESPERENNIALS HE
Calamagrostis x acutiflora 'Karl Foerster'KARL FOERSTER FEATHER REED GRASS
CONT. (2' O.C.)
FG CONT. (3' O.C.)Fothergilla gardenii DWARF FOTHERGILLA
TT
8' HT.JV Juniperus virginiana 'Skyrocket'SKYROCKET JUNIPER
SN CONT. (2' O.C.)
PATRIOT ELM
1 1/2"
Malus 'Pink Spires'12' HT.
MC Malus 'Coralburst'CORALBURST CRABAPPLE
B&BPANORWAY SPRUCEPicea abies 8' HT.
B&B8' HT.JS Juniperus scopulorum 'Medora'MEDORA JUNIPER
TC B&BTilia cordata 1 1/2" LITTLELEAF LINDEN
1062
14-HK
14-PO14-PO
14-PO14-PO14-HK
1-AT
1-AT 1-AT
1-MS
1-MS 1-MS 1-MS 1-AT
1-GB
5-HK 5-HK11-HK
1-GB
1-PA
1-UL 1-UL 1-UL 1-UL
5-HK 5-HK
1-UL 1-UL 1-UL
2-CO
2-GT
2-MC
2-MC
1-AG
1-AG
3-SB
3-TT
12-CA
14-HE
6-CA
3-VD
9-SB 6-CA 6-SB 3-VD 2-JV 10-CA 5-FG
7-TT
9-SN
3-TT 9-HE 6-CA
3-SB 2-JV 6-VD
5-FG
3-SN
E FEF
E F
E F
E F
E
H
7-TC
J
J
19-JS
E F
BISHOP DRIVE).
J. ALL AREAS IN THE RIGHT-OF-WAY WILL BE REQUIRED TO BE SODDED. (ALONG BOTH SE UNIVERSITY AVE. AND SE
DEPARTMENT.
I. PLANTING SUBSTITUTIONS SHALL BE APPROVED IN WRITING BY THE WAUKEE DEVELOPMENT SERVICES
EQUAL. APPLY AT 30 LBS/ACRE.
PROVIDE REGREEN, Tricitum aestivum, SHORT-LIVED STERILE PERENNIAL WHEAT/WHEAT GRASS HYBRID OR APPROVED
SPECIFICATIONS 9010 SEEDING.
LANE, WINONA, MN 55987, OR APPROVED EQUAL SEEDING RATE: 11.48 LBS/ACRE. INSTALL AS PER SUDAS
PROVIDE DETENTION BASIN SEED MIX AS PROVIDED BY PRAIRIE MOON NURSERY. WWW.PRAIRIEMOON.COM, 32115 PRAIRIE H.
INFORMATION.
G. SOD ALL DISTURBED AREAS UNLESS NOTED OTHERWISE. REFER TO EROSION CONTROL PLAN FOR ADDITIONAL
BEDS UNLESS OTHERWISE DIRECTED BY OWNER.
CONTRACTOR TO INSTALL BLACK PLASTIC EDGING AROUND ALL INDIVIDUAL TREE PLANTINGS AND AT PERIMETER OF ALL PLANTING F.
ALL AREAS INDICATED ON PLAN.
E. PROVIDE 3-INCH DEPTH SHREDDED HARDWOOD MULCH AROUND ALL PLANTINGS TO A MIN. 3-FOOT PERIMETER, AND IN
D. CONTRACTOR SHALL GUARANTEE ALL PLANT MATERIAL FOR A PERIOD OF ONE YEAR FROM DATE OF INSTALLATION.
NURSERY STOCK" (ANSI Z60.1-LATEST EDITION).
C. ALL PLANT MATERIAL SHALL AT LEAST MEET MINIMUM REQUIREMENTS SHOWN IN THE "AMERICAN STANDARDS FOR
CONTRACTOR'S EXPENSE. COORDINATE AND COOPERATE WITH UTILITY COMPANIES DURING CONSTRUCTION.
CONSTRUCTION. ANY DAMAGE DUE TO THE CONTRACTOR'S CARELESSNESS SHALL BE CORRECTED AT THE
EXISTENCE, EXACT LOCATION AND DEPTH OF ALL UTILITIES. AVOID DAMAGE TO UTILITIES AND SERVICES DURING
B. NOTIFY UTILITY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR DETERMINING
LOCATION INDICATED.
SERVICE OR ABANDONED. THE SURVEY FURTHER DOES NOT WARRANT THAT THE UTILITIES SHOWN ARE IN THE EXACT
SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN
THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR RECORDS OBTAINED. THE
A. UTILITY WARNING:
KEY NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
NewTechWood Ultrashield Composite Siding
NewTechWood Ultrashield Belgian Board Siding
5/8" Granitex by STO
Firestone Delta Panel System (CFP-12, CFP12F)
FACE BRICK - Glen-Gery Roman Maximus
Pre-fin Sht. Mtl. Coping/Fascia
Pre-fin Sht. Mtl. Soffit
Standing Seam Mtl. Roof
Equipment Screen
Mapes Pre-fin. Mtl. Canopy
Alum. Window/Storefront
Skylight
Reveal Joint.
Signage (N.I.C.)
Calwall Translucent Panel
WINDOW NOTES:
* WINDOW DIMENSIONS & DETAILS ARE ON A2.4
* FIELD VERIFY ALL DIMENSIONS BEFORE ORDERING
* ALL WINDOWS IN BLOCK SHALL FIT TO BLOCK INCREMENTS
* NOTE ALL WINDOWS TO BE TEMPERED AS PER THE FOLLOWING
GLAZING W/ IN 24" OF DOOR OPENINGS
GLAZING W/ IN 18" OF GROUND OR FFL
* GLASS IS TO BE 1" THERMALLY BROKEN LOW E CLEAR GLASS
SIGNAGE NOTE:
* ALL EXTERIOR SIGNAGE TO BE ON DEDICATED CIRCUIT, COORDINATE
W/ SIGNAGE PROVIDER
* SIGNAGE NOT IN CONTRACT
PROJECT ARCHITECT: JET
THE INFORMATION CONTAINED HEREIN IS OF A
PROPRIETARY NATURE AND IS SUBMITTED IN
CONFIDENCE FOR USE BY THE CLIENTS OF
MODERN DESIGN ARCHITECTS, INC. ONLY. THE
USE OF THESE DOCUMENTS FOR ANY OTHER
PROJECTS, PURPOSE, LOCATION,
PUBLICATION, REPRODUCTION OR
DISTRIBUTION IN WHOLE OR PART, BY ANY
INDIVIDUAL OR ORGANIZATION WITHOUT
WRITTEN PERMISSION FROM MODERN DESIGN
ARCHITECTS, INC. IS PROHIBITED. THE
INFORMATION HEREIN REMAINS THE
PROPERTY OF MODERN DESIGN ARCHITECTS,
INC. AND ITS USE OR DISCLOSURE TO OTHERS
IS PROHIBITED FOR ANY USE NOT
AUTHORIZED BY MODERN DESIGN
ARCHITECTS, INC.
DRAWN BY: JET
JOB NO: D348-20
DATE:
SHEET NO.
SHEET TTLE.
DRAWING ISSUE INFORMATION
ISSUE:
PERMIT SET
DATEMARK DESCRIPTION
CHECKED BY: JET
-
-
-
PRINCIPAL IN CHARGE: RJS
201 MAIN STREET
JANESVILLE, IA 50647
319-987-2101
ARCHITECTS
OPTOMETRIC
ELITE EYECARE /
ELITE VISION
THERAPY
WAUKEE, IA
File name: D348-20- A5.0 - EEC - Exterior Elevations.vwxA5.0
ELEVATIONS
7/20/20
F.F.L.
100'-0"
T.O.M.
109'-0"
T.O. PARAPET
119'-0"
T.O. PARAPET
124'-0"
T.O. CANOPY
111'-8"
T.O. PARAPET
118'-0"
F.F.L.
100'-0"
T.O. PARAPET
116'-0"
T.O. CANOPY
109'-8"
T.O.F.
97'-0"
T.O.F.
97'-0"
SIGNAGE SIGNAGE
F.F.L.
100'-0"
T.O.F.
97'-0"
F.F.L.
100'-0"
T.O.F.
97'-0"
F.F.L.
100'-0"
T.O.F.
97'-0"
T.O. CANOPY
109'-8"
T.O. PARAPET
122'-0"
T.O. PARAPET
124'-0"
T.O. PARAPET
117'-6"
T.O. PARAPET
116'-0"XA4.0XA4.01
2
2
2
1
1
1
11
3 3
3
3
3
3
33XA4.03 XA4.0XA4.033
XA4.0XA4.0XA4.06
7
8
9
1
1 1
2
3
3
3
3
5
5
5 5
5
5
5 5
3
4
4 4
4
4 4
5 5 5
6
6
6
6
6 6
6
6
6
66
6
6
6
7
7
7
7
7 7
8
8
7
8
8 8
8
8
9
9
9 9
10
10
10
10
10
10
10
10
10
10
1111
11
11
11 11 11 11 11
11
1
10
10
10
10 10
6
1111 11
11 11
11 11 11
11
11 11 11 11 11 11
12 12
12
12
14
14
14
15
T.O. PARAPET
112'-0"
T.O. PARAPET
122'-0"
T.O. PARAPET
124'-0"
F.F.L.
100'-0"
T.O.F.
97'-0"
T.O.PARAPET
116'-0"
T.O.PARAPET
119'-0"
T.O.PARAPET
121'-1 3/8"
T.O. CANOPY
111'-8"
T.O. CANOPY
109'-8"
T.O.F.
109'-8"
T.O. CANOPY
113'-8"
T.O. PARAPET
116'-0"
T.O. PARAPET
118'-0"
T.O. PARAPET
116'-0"
T.O. PARAPET
111'-0"
T.O. PARAPET
119'-4"
T.O. PARAPET
109'-8"
F.F.L.
100'-0"
T.O.F.
97'-0"
T.O. CANOPY
109'-0"
T.O. CANOPY
113'-8"
T.O. PARAPET
124'-0"
T.O. PARAPET
115'-10"
WEST ELEVATION
Scale: 3/16" = 1'-0"1
NORTH ELEVATION
Scale: 3/16" = 1'-0"2
EAST ELEVATION
Scale: 3/16" = 1'-0"3
SOUTH ELEVATION
Scale: 3/16" = 1'-0"4
PRELI
MI
N
A
R
Y
NOT FOR CONS
T
R
U
C
TI
O
N
SLOPE
8 YARD DUMPSTER 8 YARD DUMPSTER
SLOPE CONCRETE1/8":12"4
A5.1
4
A5.1
2
A5.1
3
A5.1 5A5.1ROMAN MAXIMUS BRICK 2" x 4" x 24"
PREFIN MTL. CAP FLASHINGHORIZONTAL WOOD PANEL
GRADE
8" TRENCH FOOTING
ROMAN MAXIMUS BRICK 2" x 4" x 24"
PREFIN MTL. CAP FLASHINGHORIZONTAL WOOD PANEL
GRADE
8" TRENCH FOOTING
ROMAN MAXIMUS BRICK 2" x 4" x 24"
PREFIN MTL. CAP FLASHINGHORIZONTAL WOOD PANEL
GRADE
8" TRENCH FOOTING
2" x 6" SQUARE TUBE STEEL
8" THICK OVERPOUR
2 x 8 TREATED LUMBER TOP PLATE
PREFIN. MTL. CAP FLASHING
GRADE
8" TRENCH FOOTING6" SLOPED CONCRETE
SLAB ON GRADE8" TRENCH FOOTING
4" x 8" x 16" CMU BLOCK
4" x 8" x 16" CMU BLOCK
ROMAN MAXIMUS BRICK 2" x 4" x 24"
8" THICK OVERPOUR
PAVEMENT
1/2" EXPANSION JOINT
HORIZONTAL WOOD PANEL
4" x 4" MTL. POST
2" x 6" SQUARE TUBE GATE FRAME
6" SLOPED CONCRETE
SLAB ON GRADE
8" TRENCH FOOTING 4" x 8" x 16" CMU BLOCK
4" x 8" x 16" CMU BLOCK
ROMAN MAXIMUS BRICK 2" x 4" x 24"
8" THICK OVERPOUR
HORIZONTAL WOOD PANEL
4" x 4" MTL. POST
2" x 6" SQUARE TUBE GATE FRAME
4" x 8" x 16" CMU BLOCK
ROMAN MAXIMUS BRICK 2" x 4" x 24"
HORIZONTAL WOOD PANEL
DUMPSTER ENCLOSURE PLAN
Scale: 3/8" = 1'-0"1FRONT ELEVATION
Scale: 3/8" = 1'-0"2
BACK ELEVATION
Scale: 3/8" = 1'-0"3SIDE ELEVATION
Scale: 3/8" = 1'-0"4SECTION
Scale: 3/8" = 1'-0"5
PROJECT ARCHITECT: JET
THE INFORMATION CONTAINED HEREIN IS OF A
PROPRIETARY NATURE AND IS SUBMITTED IN
CONFIDENCE FOR USE BY THE CLIENTS OF
MODERN DESIGN ARCHITECTS, INC. ONLY. THE
USE OF THESE DOCUMENTS FOR ANY OTHER
PROJECTS, PURPOSE, LOCATION,
PUBLICATION, REPRODUCTION OR
DISTRIBUTION IN WHOLE OR PART, BY ANY
INDIVIDUAL OR ORGANIZATION WITHOUT
WRITTEN PERMISSION FROM MODERN DESIGN
ARCHITECTS, INC. IS PROHIBITED. THE
INFORMATION HEREIN REMAINS THE
PROPERTY OF MODERN DESIGN ARCHITECTS,
INC. AND ITS USE OR DISCLOSURE TO OTHERS
IS PROHIBITED FOR ANY USE NOT
AUTHORIZED BY MODERN DESIGN
ARCHITECTS, INC.
DRAWN BY: JET
JOB NO: --
DATE:
--
--
SHEET NO.
SHEET TTLE.
DRAWING ISSUE INFORMATION
ISSUE:
DESIGN DEVELOPMENT
DATEMARK DESCRIPTION
CHECKED BY: JET
PRINCIPAL IN CHARGE: RJS
201 MAIN STREET
JANESVILLE, IA 50647
319-987-2101
ARCHITECTS
OPTOMETRIC
File name: D348-20- A5.0 - EEC - Exterior Elevations.vwxA5.1
ELEVATIONS
7/20/20
PROJECT ARCHITECT: JET
THE INFORMATION CONTAINED HEREIN IS OF A
PROPRIETARY NATURE AND IS SUBMITTED IN
CONFIDENCE FOR USE BY THE CLIENTS OF
MODERN DESIGN ARCHITECTS, INC. ONLY. THE
USE OF THESE DOCUMENTS FOR ANY OTHER
PROJECTS, PURPOSE, LOCATION,
PUBLICATION, REPRODUCTION OR
DISTRIBUTION IN WHOLE OR PART, BY ANY
INDIVIDUAL OR ORGANIZATION WITHOUT
WRITTEN PERMISSION FROM MODERN DESIGN
ARCHITECTS, INC. IS PROHIBITED. THE
INFORMATION HEREIN REMAINS THE
PROPERTY OF MODERN DESIGN ARCHITECTS,
INC. AND ITS USE OR DISCLOSURE TO OTHERS
IS PROHIBITED FOR ANY USE NOT
AUTHORIZED BY MODERN DESIGN
ARCHITECTS, INC.
DRAWN BY: JET
JOB NO: D348-20
DATE:
SHEET NO.
SHEET TTLE.
DRAWING ISSUE INFORMATION
ISSUE:
PERMIT SET
DATEMARK DESCRIPTION
CHECKED BY: JET
-
-
-
PRINCIPAL IN CHARGE: RJS
201 MAIN STREET
JANESVILLE, IA 50647
319-987-2101
ARCHITECTS
OPTOMETRIC
ELITE EYECARE /
ELITE VISION
THERAPY
WAUKEE, IA
File name: D348-20- A5.0 - EEC - Exterior Elevations.vwxA5.2
COLORED
ELEVATIONS
7/20/20
NORTH ELEVATION1 WEST ELEVATION2
EAST ELEVATION4SOUTH ELEVATION3
ENCLOSURE ELEVATIONS5
SIDEREAR FRONT SIDE
PROJECT ARCHITECT: JET
THE INFORMATION CONTAINED HEREIN IS OF A
PROPRIETARY NATURE AND IS SUBMITTED IN
CONFIDENCE FOR USE BY THE CLIENTS OF
MODERN DESIGN ARCHITECTS, INC. ONLY. THE
USE OF THESE DOCUMENTS FOR ANY OTHER
PROJECTS, PURPOSE, LOCATION,
PUBLICATION, REPRODUCTION OR
DISTRIBUTION IN WHOLE OR PART, BY ANY
INDIVIDUAL OR ORGANIZATION WITHOUT
WRITTEN PERMISSION FROM MODERN DESIGN
ARCHITECTS, INC. IS PROHIBITED. THE
INFORMATION HEREIN REMAINS THE
PROPERTY OF MODERN DESIGN ARCHITECTS,
INC. AND ITS USE OR DISCLOSURE TO OTHERS
IS PROHIBITED FOR ANY USE NOT
AUTHORIZED BY MODERN DESIGN
ARCHITECTS, INC.
DRAWN BY: JET
JOB NO: D348-20
DATE:
SHEET NO.
SHEET TTLE.
DRAWING ISSUE INFORMATION
ISSUE:
PERMIT SET
DATEMARK DESCRIPTION
CHECKED BY: JET
-
-
-
PRINCIPAL IN CHARGE: RJS
201 MAIN STREET
JANESVILLE, IA 50647
319-987-2101
ARCHITECTS
OPTOMETRIC
ELITE EYECARE /
ELITE VISION
THERAPY
WAUKEE, IA
File name: D348-20- A5.0 - EEC - Exterior Elevations.vwxA5.3
ELEVATION
MATERIALS
7/20/20
GLEN-GERY BRICK1COLOR: WELLINGTON
VERTICAL "WOOD"2 SIDING
BRANDYWINE
HORIZONTAL "WOOD"2 SIDINGSTO - GRANITEX2
FIRESTONE COLORS2
SLATE GRAY
BLACK