HomeMy WebLinkAbout2020-08-17-J05 Elite Eye Care_Site Plan AGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: August 17, 2020 AGENDA ITEM: Consideration of approval of a resolution approving a site plan for Elite Eye Care (1350 SE University Avenue) FORMAT: Resolution SYNOPSIS INCLUDING PRO & CON: Elite Eye Care, requests approval of a site plan to allow the construction of a 13,500 square foot building. The building is to be used for an Elite Eye Care clinic. In addition to the eye clinic there are two tenant spaces proposed on the east side of the building. Access to the site will be provided from SE University Avenue and SE Bishop Drive. The applicant has provided elevations for the proposed building on the site, which meets the intent of the architectural guidelines within the Site Plan Ordinance. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning Commission reviewed this project at the August 11, 2020 Commission Meeting and recommended approval subject to remaining staff comments: Approval of a Site Plan for Elite Eye Care (1350 SE University Ave) Senior City Planner, Melissa DeBoer, introduced the request for approval of a site plan as submitted by the applicant, Elite Eye Care, for an optometrist office. The property is generally located south of SE University Avenue and west of SE Waco Place, containing approximately 1.72 acres. Mrs. DeBoer advised that the project includes the construction of a single- story, multi-tenant building, approximately 13,500 square feet in area. The building would house Elite Eye Care with approximately 3,436 square feet available for a future tenant. The site plan also indicates a trash enclosure on the southwest corner of the site, a monument sign at the northeast corner of the site, and approximately 63 parking spaces. Access is provided from public streets to the south and north of the site and sidewalks are proposed along these public streets and interior to the site. Public utilities will serve the site, and storm water detention will be provided with a detention basin located on the west side of the site. All landscaping, open space, elevation, and lighting requirements have been met at this time. Staff would recommend approval of the site plan, subject to any remaining staff comments.  Commissioner Streit questioned if there is a potential for a drive thru in the second tenant space. Mrs. DeBoer advised that there are no cueing spaces presented on the site plan, indicating no use of a drive thru. J5  Commissioner Streit questioned if the second tenant would be GNC as their sign is used in the elevations. Jim Trinell, a representative for the applicant, advised that the signage on the elevation was for presentation purposes only to indicate the maximum signage allowances to the applicant. There is no known second tenant at this time. Commissioner Broderick moved to approve a site plan for elite Eye Care (1350 SE University Ave) subject to any remaining staff comments. The motion was seconded by Commissioner Streit. Ayes: Streit, Conley, Koshy, Broderick, and Hoifeldt. Nays: None. Motion Carries. STAFF REVIEW AND COMMENT: Staff is working with the applicant to address that last remaining comments. Staff recommends approval of the site plan subject to remaining staff comments. RECOMMENDATION: Approve the resolution subject to remaining staff comments. ATTACHMENTS: I. Proposed Resolution II. Staff Report III. Site Plan & Elevations PREPARED BY: Andy Kass, Senior Planner REVIEWED BY: THE CITY OF WAUKEE, IOWA RESOLUTION 2020- APPROVING THE SITE PLAN FOR ELITE EYE CARE (1350 SE UNIVERSITY AVENUE) IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Site Plan for Elite Eye Care, subject to remaining staff comments on August 11, 2020; AND, WHEREAS, the Site Plan for Elite Eye Care is in general conformance with §160 – Site and Building Development Standards Ordinance of the Waukee Municipal Code; AND, WHEREAS, the Site Plan for Elite Eye Care is in general conformance with §161 – Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND, NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 21st day of August, 2020 that the Site Plan for Elite Eye Care is approved subject to remaining staff comments. BE IT FURTHER RESOLVED that the City of Waukee does hereby accept the following easements related to the site plan to be filed with the Dallas County Recorder: 1. Detention Easement ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Anna Bergman R. Charles Bottenberg Chris Crone Larry R. Lyon Ben Sinclair PLANNING AND ZONING COMMISSION STAFF REPORT PROJECT: Elite Eye Care – Site Plan PREPARED BY: Melissa DeBoer, AICP – Senior Planner REPORT DATE: August 7, 2020 MEETING DATE: August 11, 2020 GENERAL INFORMATION Owner: Hawthorne Pointe, LLC Applicant: Elite Eye Care Owner’s Representative: Korey Marsh, PE – Snyder & Associates, Inc. Request: The applicant is requesting approval of a site plan for an optometrist office. Location and Size: Property is generally located south of SE University Avenue and west of SE Waco Place, containing approximately 1.72 acres. Property Address: 1350 SE University Avenue AREA MAP ABOVE: Aerial of Property identifying the proposed plat (outlined in BLUE). August 7, 2020 2 of 3 LAND USES AND ZONING Location Existing Land Use Comprehensive Plan Current Zoning Property in Question Vacant – Undeveloped Community Commercial C-1 / PD-1 (Community and Highway Service Commercial District / Planned Development District) North Multi-Family Residential / Single Family Residential High Density Residential / Single Family Residential R-3 / PD-1 (Multi-Family Residential District / Planned Development District); C-4 / PD-1 (Office Park Commercial District / Planned Development District); R-2 / PD-1 (One and Two Family Residential District / Planned Development District) South Apartments / Townhomes Medium Density Residential C-1 / PD-1 (Community and Highway Service Commercial District / Planned Development District) East Vacant – Undeveloped Community Commercial C-1 / PD-1 (Community and Highway Service Commercial District / Planned Development District) West Commercial Community Commercial C-1 / PD-1 (Community and Highway Service Commercial District / Planned Development District) PROJECT DESCRIPTION The project includes the construction of a single-story, multi-tenant building. The building is proposed to be about 13,500 square feet in area. The majority of the building will be the space for Elite Eye Care (10,080 sq ft) and a smaller tenant space (3,436 sq ft) will be available for a future tenant. The main entrance to the building is located on the north side, facing SE University Avenue. A trash enclosure is proposed at the southwest corner of the site and a monument sign is shown at the northeast corner of the site, along SE University Avenue. ACCESS AND PARKING There are two accesses into this site from the public streets. One is located to the south off of SE Bishop Drive and this is a shared access with the dentist office to the west. The other access is located to the north off of SE University Avenue. A total of 41 parking spaces are required for this facility. The total amount of parking proposed is 63 spaces including 3 accessible stalls. The site plan also identifies a bicycle rack located on the north side of the building. The proposed site plan meets the parking requirements. The site plan also calls out an area at the south side of the site as future parking; this includes a possibility of 18 spaces if needed at some point in the future. August 7, 2020 3 of 3 SIDEWALKS/TRAILS Five foot wide sidewalks will be installed along SE Bishop Drive on the south and SE University Avenue on the north. Sidewalks are proposed interior to the site in order to provide pedestrian connections from the parking lot to the proposed building and around the building. UTILITIES This site will be serviced with all public utilities. Water and sanitary sewer will be brought in from the mains located to the south along SE Bishop Drive. Storm water detention will be provided with a detention basin located at the west side of the site. LANDSCAPING & OPEN SPACE A minimum of 15% of the project area is required to be open space. The total amount of open space proposed is 39%. The landscape plan meets the requirements of the Landscape and Open Space Ordinance and the Kettlestone Design Guidelines. ELEVATIONS The elevations of the building are proposed to be constructed mostly of composite wood siding, brick, architectural metal accents, aluminum storefront system and a metal roof. MISCELLANEOUS: The applicant has submitted a photometric plan and associated light fixture cut sheets. The lighting plan meets the lighting requirements of the Site Plan Ordinance. COMPREHENSIVE PLAN The comprehensive plan classifies the subject property as Community Commercial. The Community Commercial classification provides a variety of uses that would serve the community and are located along minor or major arterials. STAFF RECOMMENDATION The site plan is in general conformance with the Site Plan Ordinance and Comprehensive Plan. Staff recommends approval of the site plan for Elite Eye Care subject to remaining staff comments. 1"= 120.0504KMMEDCRMM120.050488WAUKEE, IOWA BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= ZARNESONV:\Projects\2020\120.0504.01\CADD\SP_1200504_01TSH.dgn7/22/20205:05:23 PMSnyder1:500Y:\pen\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS06/23/20RMM6/09/2020ELITE EYE CARE - WAUKEE2REVISED AS PER CITY COMMENTS07/07/20RMM3REVISED AS PER CITY COMMENTS07/22/20RMMINDEX OF SHEETS PROJECT LOCATION VICINITY MAP STATE OF IO WA PROFESSIO N ALLANDSCAPE AR CHITECTDate License Number Pages or sheets covered by this seal: 668 NO. ARCHITECT LANDSCAPE under the laws of the State of Iowa. Professional Landscape Architect charge. I am a duly licensed direct supervision and responsible below was prepared by me or under my this technical submission described I hereby certify that the portion of June 30, 2018 License Expires: 668 GULDENPFENNIG LARA F. Lara F. Guldenpfennig, ASLASE BRICK DRSE ALICE'S RDSE UNIVERSITY AVE.98TH STREETGRAND PRARIE PKWY1TITLE SHEET1 OWNER 8. 7. 6. 5. 4. 3. 2. 1.500'1"=500' CITY OF WAUKEE, DALLAS COUNTY, IOWA 1350 SE UNIVERSITY AVENUE FOR SITE PLAN LANDSCAPE PLAN SIDEWALK RAMP DETAILS EROSION AND SEDIMENT CONTROL PLAN GRADING PLAN UTILITY PLAN DIMENSION PLAN PROJECT INFORMATION TITLE SHEET SHEET 1-7 SHEET 8 State of Iowa. Professional Engineer under the laws of the supervision and that I am a duly licensed was prepared by me or under my direct personal I hereby certify that this engineering document Date License Number My License Renewal Date is December 31, 2020 Pages or sheets covered by this seal: P25347LICENSEDPROFEIONALEN GI NEERAIOW SS Korey M. Marsh, P.E. P25347 MARSH KOREY M. DR SE BISHOP SE EMERALD DRARCHITECT PHONE: (319) 987-2101 CONACT: DANIEL HALBACH JANESVILLE, IA 50647 P.O. BOX 461 201 MAIN STREET MODERN DESIGN ARCHITECTS ELITE EYE CARE - WAUKEE EMAIL: JJOHNSON@ACCURATEDEVELOPMENT.COM PHONE: 515-566-0124 CONTACT: JARED T JOHNSON WEST DES MOINES, IA 50266 9500 SE UNIVERSITY AVE SUITE 2112 HAWTHORNE POINTE, LLC 1"= 120.0504KMMEDCRMM120.050488WAUKEE, IOWA BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= ZARNESONV:\Projects\2020\120.0504.01\CADD\SP_1200504_02NTS.dgn7/22/20205:05:24 PMSnyder1:1Y:\pen\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS06/23/20RMM6/09/2020ELITE EYE CARE - WAUKEE2REVISED AS PER CITY COMMENTS07/07/20RMM3REVISED AS PER CITY COMMENTS07/22/20RMM2 2PROJECT INFORMATIONPARKING REQUIREMENTS: 93 93.0 93 C OC FO E OE 4" G 4" HPG 8" W 8" S 12" ST12" ST G G AST UST Features Existing Proposed G EB W LEGEND 8" W(*) 8" S(*) 4" G(*) 4" HPG(*) C(*) OC(*) FO(*) E(*) OE(*) DUCT(*) 93.0 1 Soil Boring Mailbox Satellite Dish Sign Above Ground Storage Tank Underground Storage Tank Fence Post or Guard Post Gas Apparatus Gas Manhole Gas Valve Fiber Optic Handhole Fiber Optic Manhole Communication Handhole Communication Manhole Communication Pedestal Traffic Sign Electric Transformer Electric Box Yard Light Street Light Utility Pole with Transformer Utility Pole with Light Guy Anchor Utility Pole Well Water Service Valve Water Main Valve Fire Hydrant on Building Fire Hydrant Double Storm Sewer Intake Single Storm Sewer Intake Storm Manhole Storm Sewer with Size Sanitary Manhole (*) Denotes the survey quality service level for utilities Test Hole Location for SUE w/ID Duct Bank Sanitary Sewer with Size Water Main with Size High Pressure Gas Main with Size Gas Main with Size Overhead Electric Underground Electric Fiber Optic Overhead Communication Communication Coniferous Tree or Shrub Deciduous Tree or Shrub Tree Stump Tree Line Fence (Silt) Fence (Wood) Fence (Chain Link) Fence (Barbed, Field, Hog) Contour Elevation Spot Elevation UTILITY WARNING UTILITY QUALITY SERVICE LEVELS THE TYPE, SIZE, CONDITION, MATERIAL, AND OTHER CHARACTERISTICS. BY ACTUAL EXPOSURE OR VERIFICATION OF PREVIOUSLY EXPOSED SUBSURFACE UTILITIES, AS WELL AS IS HORIZONTAL AND VERTICAL POSITION OF UNDERGROUND UTILITIES OBTAINEDQUALITY LEVEL (A) SUBSURFACE UTILITIES. GEOPHYSICAL METHODS TO DETERMINE THE EXISTENCE AND APPROXIMATE HORIZONTAL POSITION OF INFORMATION IS OBTAINED THROUGH THE APPLICATION OF APPROPRIATE SURFACE QUALITY LEVEL (B) QUALITY D INFORMATION. UTILITY FEATURES AND USING PROFESSIONAL JUDGMENT IN CORRELATING THIS INFORMATION WITH INFORMATION IS OBTAINED BY SURVEYING AND PLOTTING VISIBLE ABOVE-GROUND QUALITY LEVEL (C) INFORMATION IS DERIVED FROM EXISTING UTILITY RECORDS OR ORAL RECOLLECTIONS.QUALITY LEVEL (D) APPLICABLE, SIZE. THE QUALITY LEVELS ARE BASED ON THE CI / ASCE 38-02 STANDARD. QUALITY LEVELS OF UTILITIES ARE SHOWN IN THE PARENTHESES WITH THE UTILITY TYPE AND WHEN EXCEPT WHERE NOTED AS QUALITY LEVEL A. UTILITIES OR SUBSURFACE FEATURES SHOWN ARE IN THE EXACT LOCATION INDICATED SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE SUBSURFACE FEATURES SHOWN COMPRISE ALL SUCH ITEMS IN THE AREA, EITHER IN RECORDS OBTAINED. THE SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES OR THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR GENERAL NOTES BULK REGULATIONS ZONING GENERAL USE IMPERVIOUS AREA PERVIOUS AREA LEGAL DESCRIPTION 53,014 SF 22,025 SF TOTAL AREA OF DISTURBANCE 1.72 AC BEING AN OFFICIAL PLAT DALLAS COUNTY, IOWA. LOT 1, COVE AT KETTLESTONE PLAT 3 RECORDED WITH BOOK 2016 PAGE 2362 COMMERCIAL DISTRICT) (COMMUNITY AND HIGHWAY SERVICE PLANNED UNIT DEVELOPMENT/ C-1 RETAIL/GENERAL COMMERCIAL N/ANAD83(2011)(EPOCH 2010.00) IARTN DERIVED - US SURVEY FEET IOWA STATE PLANE SOUTH COORDINATE SYSTEM CONTROL POINTS BENCHMARKS IARTN DERIVED - US SURVEY FEET NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88 - GEOID12A) CP4 CP3 CP2 CP1 BM2 BM1 SOUTH SIDE SE BISHOP DRIVE. BURY BOLT ON HYDRANT, IN FRONT OF UNIT #1296, ELEV=1062.50 SOUTH SIDE SE BISHOP DRIVE. BURY BOLT ON HYDRANT, IN FRONT OF UNIT #1356, ELEV=1061.03 COOPERATE TO PROVIDE INFORMATION UNDER THE RESPONSIBILITY OF OTHERS.f. UPDATE AND MAINTAIN THE ONSITE SWPPP.e. WEEKLY INSPECTIONS AND CORRESPONDING RECORDS.d. MEASURES. INSTALL, MAINTAIN, AND REMOVE EROSION CONTROL AND POLLUTION PREVENTION c. COMPLY WITH THE REQUIREMENTS OF THE GENERAL PERMIT No.2 AND THE SWPPP.b. CERTIFICATION OF SUBCONTRACTOR CO-PERMITEES. SIGN NPDES CERTIFICATION STATEMENT AS CO-PERMITEE AND COORDINATING a. RESPONSIBILITIES OF THE CONTRACTOR:3. SUBMIT THE NOTICE OF DISCONTINUATION.d. COVERAGE. FILE THE NOTICE OF INTENT WITH APPLICATION FEE FOR NPDES GENERAL PERMIT No. 2 c. PUBLISH THE PUBLIC NOTICE OF STORM WATER DISCHARGE.b. CREATE THE INITIAL SWPPP.a. RESPONSIBILITIES OF THE ENGINEER:2. b. ALL REQUIREMENTS NOT ASSIGNED TO OTHERS. a. SIGN NPDES CERTIFICATION STATEMENT AS PERMITEE. RESPONSIBILITIES OF THE OWNER:1. PROJECT SPECIFIC REQUIREMENTS FOR POLLUTION PREVENTION AND EROSION PROTECTIOND. FILING OF THE "NOTICE OF DISCONTINUATION". REMOVE ALL TEMPORARY EROSION CONTROL MEASURES AND SITE WASTE PRIOR TO k. MUST BE CONTAINED ONSITE. SEDIMENT BASIN OR OTHER CONTROL DEVICE WHERE POSSIBLE. CONCRETE WASHOUT STAGING AREAS WITH DIVERSION BERMS AND/OR SILT BARRIERS AND DIRECT TO A MATERIALS STORAGE, AND CONCRETE WASHOUT FACILITY. CONTROL RUNOFF FROM JOB TRAILERS, FUELING / VEHICLE MAINTENANCE AREA, TEMPORARY SANITARY FACILITIES, SWPPP. UNLESS NOTED OTHERWISE, STAGING AREAS SHOULD CONTAIN THE FOLLOWING: COORDINATE LOCATIONS OF STAGING AREAS WITH THE OWNER AND RECORD IN THE j. EXCEEDING 14 CALENDAR DAYS. CEASED ON ANY PORTION OF THE SITE AND WHICH WILL NOT RESUME FOR A PERIOD IMMEDIATELY AFTER CONSTRUCTION ACTIVITY IS FINALLY COMPLETED OR TEMPORARILY COMPLETION OR DELAY OF GRADING OPERATIONS. INITIATE STABILIZATION MEASURES PERMANENT SEED MIX, SOD, OR PAVEMENT IMMEDIATELY AS SOON AS POSSIBLE UPON STABILIZE UNDEVELOPED, DISTURBED AREAS WITH MULCH, TEMPORARY SEED MIX, i. ARE LOCATED. ALL DISTURBED AREAS, EXCEPT WHERE PAVEMENT, BUILDINGS OR OTHER IMPROVEMENTS RESPREAD A MINIMUM OF 8 INCHES OF TOPSOIL (INCLUDING TOPSOIL FOUND IN SOD) ON h. SEWERS ARE INSTALLED. RUNOFF CONTROL. PROVIDE INLET AND OUTLET CONTROL MEASURES AS SOON AS STORM GRADES AND AS CONSTRUCTION OPERATIONS PROGRESS TO ENSURE CONTINUOUS MATS, MULCH, DITCH CHECKS OR RIPRAP AS SOON AS AREAS REACH THEIR FINAL INSTALL NECESSARY CONTROL MEASURES SUCH AS SILT BARRIERS, EROSION CONTROL g. DEBRIS IMMEDIATELY AND TAKE REMEDIAL ACTIONS FOR FUTURE PREVENTION. DRAINAGEWAYS, OR UNDERGROUND SEWERS. REMOVE ANY ACCUMULATION OF EARTH OR ADJOINING PUBLIC OR PRIVATE PROPERTIES, INCLUDING STREETS, DRIVEWAYS, SIDEWALKS, PREVENT ACCUMULATION OF EARTH AND DEBRIS FROM CONSTRUCTION ACTIVITIES ON f. SWPPP AND IMPLEMENT ANY RECOMMENDED MEASURES WITHIN 7 DAYS. SUBMITTED WEEKLY TO THE OWNER OR ENGINEER DURING CONSTRUCTION. REVISE THE OF THESE INSPECTIONS AND ANY RESULTING ACTIONS IN THE SWPPP WITH A COPY ASSIGNED BY THE CONTRACTOR) EVERY SEVEN CALENDAR DAYS. RECORD THE FINDINGS INSPECT THE PROJECT AREA AND CONTROL DEVICES (BY QUALIFIED PERSONNEL e. THE MEASURES HAVE LOST 50% OF THEIR ORIGINAL CAPACITY. THROUGHOUT THE PERMIT PERIOD. CLEAN OR REPLACE SILT CONTROL DEVICES WHEN ORDER, INCLUDING CLEANING, REPAIRING, REPLACEMENT, AND SEDIMENT REMOVAL MAINTAIN ALL TEMPORARY AND PERMANENT EROSION CONTROL MEASURES IN WORKING d. TIME. TO A MINIMUM THE TOTAL AREA DISTURBED BY CONSTRUCTION OPERATIONS AT ANY PRESERVE EXISTING VEGETATION IN AREAS NOT NEEDED FOR CONSTRUCTION AND LIMIT c. DISTURBING ACTIVITIES PRIOR TO SITE CLEARING AND GRADING OPERATIONS. DITCH CHECKS, DIVERSION BERMS, OR SEDIMENTATION BASINS DOWNSTREAM OF SOIL INSTALL PERIMETER AND FINAL SEDIMENT CONTROL MEASURES SUCH AS SILT BARRIERS, b. AND MAXIMIZE STORM WATER INFILTRATION, AND MINIMIZE SOIL COMPACTION. WATERS, DIRECT STORM WATER TO VEGETATED AREAS TO INCREASE SEDIMENT REMOVAL DISCHARGING FROM BASINS, PROVIDE AND MAINTAIN NATURAL BUFFERS AROUND SURFACE UTILIZE OUTLET STRUCTURES THAT WITHDRAW WATER FROM THE SURFACE WHEN a. UNLESS INFEASIBLE OR NOT APPLICABLE: GENERAL PERMIT AND SWPPP, INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING BMP'S THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL REQUIREMENTS OF THE 4. PROGRESS AND CHANGES AT THE PROJECT SITE. THE SWPPP AND SITE MAP SHOULD BE EXPEDITIOUSLY REVISED TO REFLECT CONSTRUCTION 3. FROM THOSE SHOWN ON THE PLAN MAY BE REQUIRED. RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY, NOTE AND IMPLEMENT. ADDITIONAL BMP'S CONTROL MEASURES REQUIRED AS A RESULT OF CONSTRUCTION ACTIVITIES ARE THE COMPLIANCE WITH THE PROJECT'S NPDES PERMIT COVERAGE. ALL BMP'S AND EROSION THE SWPPP ILLUSTRATES GENERAL MEASURES AND BEST MANAGEMENT PRACTICES (BMP) FOR 2. DURING CONSTRUCTION. ADDITIONAL REQUIREMENTS AND MODIFICATIONS TO THE POLLUTION PREVENTION PLAN MADE ADDITION TO THESE PLAN DRAWINGS. THE CONTRACTOR SHOULD REFER TO THE SWPPP FOR THE STORM WATER POLLUTION PREVENTION PLAN (SWPPP) IS A SEPARATE DOCUMENT IN 1. C. POLLUTION PREVENTION PLAN AND/OR SUBMITTAL OF THE NOTICE OF DISCONTINUATION. COPY AND PROVIDE THE ORIGINAL DOCUMENTS TO THE OWNER UPON PROJECT ACCEPTANCE OF THREE YEARS AFTER PROJECT COMPLETION. THE CONTRACTOR SHALL RETAIN A RECORD ALL PLANS, INSPECTION REPORTS, AND OTHER DOCUMENTS MUST BE RETAINED FOR A PERIOD OF THE DISTURBED SITE AND REMOVAL OF ALL TEMPORARY EROSION CONTROL MEASURES. A "NOTICE OF DISCONTINUATION" MUST BE FILED WITH THE IDNR UPON FINAL STABILIZATION 3. WATER ACT AND THE CODE OF IOWA. FAILURE TO COMPLY WITH THE NPDES PERMIT REQUIREMENTS IS A VIOLATION OF THE CLEAN AT ALL TIMES AND MUST BE PRESENTED TO ANY JURISDICTIONAL AGENCIES UPON REQUEST. LETTER, CURRENT SWPPP, SITE INSPECTION LOG, AND OTHER ITEMS, SHALL BE KEPT ON SITE LIMITED TO, THE NOTICE OF INTENT, PROOF OF PUBLICATIONS, DISCHARGE AUTHORIZATION ALL DOCUMENTS RELATED TO THE STORM WATER DISCHARGE PERMIT, INCLUDING, BUT NOT 2. DOCUMENTS. ALL REQUIREMENTS OF THE NPDES GENERAL PERMIT NO. 2 AS SPECIFIED IN THE CONTRACT AND ALL SUBCONTRACTORS ARE RESPONSIBLE FOR COMPLIANCE WITH AND FULFILLMENT OF REQUIRED BY THE ENVIRONMENTAL PROTECTION AGENCY (EPA). THE GENERAL CONTRACTOR WATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITIES FROM THE IDNR, AS THIS PROJECT REQUIRES COVERAGE UNDER THE NPDES GENERAL PERMIT NO. 2 FOR STORM 1. B. STORM WATER DISCHARGE PERMIT ITEMS AND DEDUCT THE COST THEREOF FROM AMOUNTS DUE TO THE CONTRACTOR. ADJOINING PUBLIC OR PRIVATE PROPERTY, THE OWNER MAY, BUT NEED NOT, REMOVE SUCH STEPS TO PROMPTLY REMOVE EARTH SEDIMENTATION OR DEBRIS WHICH COMES ONTO FEES INCURRED TO OWNER. FURTHER, IF THE CONTRACTOR FAILS TO TAKE NECESSARY DAMAGES TO ADJOINING PUBLIC OR PRIVATE PROPERTY, INCLUDING REASONABLE ATTORNEY HARMLESS FROM ANY AND ALL CLAIMS OF ANY TYPE WHATSOEVER RESULTING FROM DAMAGE CLAIMS: THE CONTRACTOR WILL HOLD THE OWNER AND ARCHITECT / ENGINEER 2. BORROW OR DEPOSIT AREAS DURING PERFORMANCE OR AS A RESULT OF PERFORMANCE. PROTECT AGAINST EROSION AND POLLUTION FROM THIS PROJECT SITE AND ALL OFF-SITE ANY LOCAL ORDINANCES. THE CONTRACTOR SHALL TAKE ALL NECESSARY STEPS TO DEPARTMENT OF NATURAL RESOURCES (IDNR) NPDES PERMIT, THE U.S. CLEAN WATER ACT AND POLLUTION AND SOIL EROSION CONTROL REQUIREMENTS OF THE IOWA CODE, THE IOWA CODE COMPLIANCE: THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL POTENTIAL 1. A. POLLUTION PREVENTION AND EROSION PROTECTION POLLUTION PREVENTION NOTES UTILITY CONTACT INFORMATION SYSTEM, TICKET NUMBER 552003655. RECEIVED FROM THE IOWA ONE CALL DESIGN REQUEST UTILITY CONTACT FOR MAPPING INFORMATION SHOWN AS JACK@GRM.NET 515-897-9192 JACK JONES MI-FIBER PMAY@MEDIACOMCC.COM 515-246-2252 PAUL MAY MEDIACOM COMMUNICATIONS CORP LOCATES@ICS-LLC.NET 515-268-4045 ADAM WOODARD INTERNET CONSULTING SERVICES, JUSTIN.GREV@CONSOLIDATED.COM 507-386-3606 JUSTIN GREV CONSOLIDATED COMMUNICATIONS THOMAS.STURMER@CENTURYLINK.COM 720-578-8090 TOM STURMER CENTURYLINK JEFF.KLOCKO@AUREON.COM 515-830-0445 JEFF KLOCKO AUREON NETWORK SERVICES NO RESPONSE CLEAR NO RESPONSE NO RESPONSE C1-COMMUNICATIONS FO2-FIBER OPTIC F01-FIBER OPTIC G-GAS S-SANITARY SEWER W-WATER FO4-FIBER OPTIC FO3-FIBER OPTIC NO RESPONSE OE-OVERHEAD ELECTRIC E-ELECTRIC TROYER@WAUKEE.ORG 515-978-7920 TIM ROYER WAUKEE, CITY OF LOCATE.DESK@WINDSTREAM.COM 800-289-1901 LOCATE DESK WINDSTREAM COMMUNICATIONS UPNGIS@UPNFIBER.COM 816-425-3556 JOE KILZER UNITE PRIVATE NETWORKS, LLC RYAN@NEXGENCOM.COM 515-369-7131 RYAN ROLWES NEXGEN INTEGRATED COMMUNICATIO MECDSMDESIGNLOCATES@MIDAMERICAN.COM 515-252-6632 CRAIG RANFELD MIDAMERICAN ENERGY }20' NORTH OF POWER POLE, }75' SOUTH OF HYDRANT. SET CUT "X" AT SOUTH BACK OF CURB SE UNIVERSITY AVE, N=583246.40 E=1545986.91 ELEV=1058.54 }5' NORTH OF STREET LIGHT, }150' EAST OF EMERALD DRIVE. SET CUT "X" AT SOUTH BACK OF CURB SE UNIVERSITY AVE, N=583247.92 E=1545528.02 ELEV=1058.62 SOUTH ENTRANCE. BISHOP DRIVE, }5' NORTH OF STREET LIGHT, }50' WEST OF SET CUT "X" AT SOUTH BACK OF CURB INTAKE OF SE N=582898.81 E=1545491.01 ELEV=1060.50 ENTRANCE. SIDE OF SE BISHOP DRIVE, }40' WEST OF TOWNHOME SET CUT "X" AT DOUBLE BACK OF CURB INTAKE, SOUTH N=582886.23 E=1545932.77 ELEV=1058.72 MINIMUM OPEN SPACE = 15% ADJACENT TO RESIDENTIAL REAR YARD = NONE EXCEPT FOR 25 FEET ADJACENT TO RESIDENTIAL SIDE YARD = NONE EXCEPT FOR 10 FEET LOT AREA = NONE FRONT YARD= ZERO (0') MINIMUM , NO MAXIMUM ACCESSIBLE SPACES ) (INCLUDING 3 HANDICAP 63 SPACES PROVIDED 41 SPACES REQUIRED (13,516 SF / 1000 SF) x 3 SPACES =41 SPACES RETAIL/ GENERAL COMMERCIAL: 3 SPACES PER 1000 SF OF PROFESSIONAL/BUSINESS OFFICES AROUND THE EXTERIOR OF THE BUILDING OR FACILITY. OF THE EXTERIOR WALLS OF THE FIRST STORY OF THE BUILDING AS MEASURED BY AN APPROVED ROUTE THE REQUIREMENTS OF SECTION 503.2 AND THIS SECTION SHALL EXTEND TO WITHIN 100 FEET OF ALL PORTIONS A BUILDING AS SOON AS CONSTRUCTION COMMENCES. THE FIRE APPARATUS ACCESS ROAD SHALL COMPLY WITH EE. APPROVED FIRE APPARATUS ACCESS ROADS SHALL BE PROVIDED FOR EVERY FACILITY, BUILDING, OR PORTION OF COORDINATE ANY LANE/ROAD CLOSURES WITH THE CITY OF WAUKEE. NOTIFYING DRIVERS OF LANE CLOSURES AT LEAST ONE WEEK PRIOR TO ANY CLOSURE. CONTRACTOR IS TO DD. PRIOR TO ANY LANE CLOSURE THE CONTRACTOR IS RESPONSIBLE FOR HAVING A DIGITAL MESSAGE BOARD CONSTRUCTION. CC. CONTRACTOR IS TO PROVIDE SHOP DRAWING SUBMITTALS OF CONSTRUCTION MATERIALS PRIOR TO BB. ALL FIRE HYDRANTS WILL BE REQUIRED TO HAVE 4-INCH STORZ FITTINGS. AND CITY OF WAUKEE ENGINEERING DEPARTMENT SHALL WITNESS ALL TIE-INS. AA. CONTRACTOR SHALL COORDINATE ALL TIE-IN TO UTILITIES WITH THE CITY OF WAUKEE ENGINEERING DEPARTMENT SLURRY FROM CONCRETE OPERATIONS TO DISCHARGE OFFSITE. Z. CONSTRUCTION OPERATIONS SHALL PROTECT STORM SEWERS AND DRAINAGE WAYS FROM ALLOWING CONCRETE SHALL WITNESS ALL TESTING. SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND ALL UTILITIES SHALL BE TESTED TO CITY STANDARDS. THE CITY Y. ALL UTILITIES INCLUDING PRIVATE UTILITIES SHALL BE CONSTRUCTED TO THE CITY OF WAUKEE STANDARD SHALL PROVIDE INFORMATION TO THE DESIGN ENGINEER FOR INCLUSION ON THE RECORD AS-BUILT DRAWINGS. GRADES FOR DRAINAGE SWALES, OVERFLOWS, ACCESSIBLE RAMPS AND DETENTION FACILITIES. THE CONTRACTOR X. AS-BUILTS SHALL BE PROVIDED TO THE WAUKEE ENGINEERING DEPARTMENT INCLUDING ALL UTILITIES AND AS-BUILT EXPANSION JOINTS SHALL BE SEALED. JOINT BETWEEN SIDEWALKS AND PCC PAVEMENT. THE PCC RAMP JOINT LOCATED AT THE BACK OF CURB AND ALL W. PLACE 3/4" EXPANSION JOINT BETWEEN ALL PCC PAVEMENT/SIDEWALKS AND BUILDINGS. PLACE 1/2" EXPANSION TO THE CITY OF WAUKEE. ALL SANITARY SEWER MANHOLES SHALL BE VACUUM TESTED. WAUKEE SHALL WITNESS ALL CLEANING AND TELEVISING. COPIES OF THE REPORT AND VIDEO SHALL BE PROVIDED V. ALL SANITARY SEWER AND STORM SEWER SHALL BE CLEANED AND TELEVISED PRIOR TO PAVING. THE CITY OF GRANTED APPROVAL IN WRITING BY THE CITY OF WAUKEE DEVELOPMENT SERVICES DEPARTMENT. U. THE CONTRACTOR IS RESPONSIBLE FOR ANY CHANGES MADE DURING CONSTRUCTION THAT HAVE NOT BEEN CITY OF WAUKEE DEVELOPMENT SERVICES DEPARTMENT PRIOR TO CONSTRUCTION. T. ANY CHANGES PROPOSED TO THE DRAWINGS DURING CONSTRUCTION SHALL BE APPROVED IN WRITING BY THE PEDESTRIAN FACILITIES. S. ALL STAKING SHALL BE DONE UNDER THE DIRECTION OF A LICENSED ENGINEER OR LAND SURVEYOR INCLUDING CONSTRUCTION ACTIVITIES BEGINNING. R. A PRE-CONSTRUCTION MEETING WITH THE CITY OF WAUKEE WILL BE REQUIRED A MINIMUM OF ONE WEEK PRIOR TO DISTANCE FROM THE WATER MAIN TO THE STORM SEWER IS AT LEAST TEN FEET. GREATER. O-RING GASKET JOINTS SHALL BE INSTALLED ON EACH SIDE OF THE CROSSING UNTIL THE NORMAL SEWER SHALL BE CONSTRUCTED OF REINFORCED CONCRETE WITH A FLEXIBLE O-RING GASKET RATED AT 13 PSI OR Q. IF STORM SEWER CROSSES ABOVE WATER MAIN OR CROSSES LESS THAN 18" BELOW A WATER MAIN THEN STORM SERVICES WITH UTILITY SERVICE PROVIDER, CITY OF WAUKEE, AND THE OWNER PRIOR TO CONSTRUCTION. P. CONTRACTOR TO COORDINATE NATURAL GAS, ELECTRICAL, TELEPHONE AND ANY OTHER FRANCHISE UTILITY SHALL BE MET BY CONTRACTOR. A COSESCO PERMIT IS REQUIRED FOR THIS PROJECT. MEASURES ON SITE AT THE TIME OF CONSTRUCTION. GRADING AND SOIL EROSION CONTROL CODE REQUIREMENTS NECESSARY. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR MAINTAINING ANY EXISTING EROSION CONTROL O. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING EROSION AND SEDIMENT CONTROL MEASURES AS SITE WORK. N. THE ADJUSTMENT OF ANY EXISTING UTILITY APPURTENANCES TO FINAL GRADE IS CONSIDERED INCIDENTAL TO THE EVENT. SIDEWALKS CAUSED BY CONSTRUCTION ACTIVITIES AT THE END OF EACH WORK DAY AND PRIOR TO A RAIN M. THE CONTRACTOR IS RESPONSIBLE FOR CLEANING DIRT AND DEBRIS FROM NEIGHBORING STREETS, DRIVEWAYS, AND (GUTTER), UNLESS OTHERWISE NOTED. L. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS SHOWN ARE FINISHED GRADES AND/OR TOP OF PAVING SLAB GRADES TO MEET SUDAS SPECIFICATIONS SECTION 2010 FOR TOPSOIL. K. CONTRACTOR TO STRIP AND STOCKPILE TOPSOIL FROM ALL AREAS TO BE CUT OR FILLED. RESPREAD TO FINISH INTO THE PROJECT TO AN APPROVED OFF-SITE WASTE SITE. J. CONTRACTOR TO LOAD AND TRANSPORT ALL MATERIALS CONSIDERED TO BE UNDESIRABLE TO BE INCORPORATED WAUKEE STANDARDS. ANY CHANGES COMPLETED WITHOUT APPROVAL ARE SUBJECT TO REMOVAL IN ORDER TO MEET THE CITY OF IMPROVEMENTS PRIOR TO CONSTRUCTION. CONTACT CITY OF WAUKEE FOR APPROVAL OF ANY CHANGES AND THAT STARTING CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LAYOUT VERIFICATION OF ALL SITE BETWEEN THIS PLAN AND FIELD CONDITIONS ARE TO BE REPORTED TO THE ARCHITECT/ENGINEER PRIOR TO THE TIME OF DESIGN. DEVIATIONS MAY BE NECESSARY IN THE FIELD. ANY SUCH CHANGES OR CONFLICTS I. DIMENSIONS, BUILDING LOCATION, UTILITIES AND GRADING OF THIS SITE ARE BASED ON AVAILABLE INFORMATION AT ACCORDINGLY ON THE AS-BUILT DOCUMENTS. H. ALL FIELD TILES ENCOUNTERED DURING CONSTRUCTION SHALL BE RECONNECTED OR REPAIRED AND NOTED PLANS SHALL GOVERN. G. IN THE EVENT OF A DISCREPANCY BETWEEN THE QUANTITY ESTIMATES AND THE DETAILED PLANS, THE DETAILED COMPACT TO 95% MAXIMUM DENSITY. F. CONSTRUCT MANHOLES AND APPURTENANCES AS WORK PROGRESSES. BACKFILL WITH SUITABLE MATERIAL AND WEEKEND OR HOLIDAY WORK. ALSO NOTIFY THE CITY OF WAUKEE PUBLIC WORKS DEPARTMENT AT LEAST 48 HOURS PRIOR TO ANY PLANNED E. NOTIFY OWNER, ENGINEER, CITY OF WAUKEE AT LEAST 48 HOURS PRIOR TO BEGINNING WORK. CONTRACTOR SHALL ANTICIPATED LANE CLOSURE. AND ACTIONS. THE CONTRACTOR SHALL NOTIFY THE CITY OF WAUKEE AT LEAST ONE WEEK PRIOR TO ANY ROADWAY, FLAGGERS SHALL BE PROVIDED. FLAGGERS SHALL CONFORM TO THE MUTCD IN APPEARANCE, EQUIPMENT UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). WHEN CONSTRUCTION ACTIVITIES OBSTRUCT PORTIONS OF THE D. ALL TRAFFIC CONTROL SHALL BE PROVIDED IN ACCORDANCE WITH REQUIREMENTS SET FORTH IN THE MANUAL ON STRUCTURE. C. LENGTH OF UTILITIES SHOWN ON PLANS ARE DIMENSIONED FROM CENTERLINE OF STRUCTURE TO CENTERLINE OF REPORTS PREPARED BY OTHERS. SPECIFICATIONS FOR PUBLIC IMPROVEMENTS, STATEWIDE URBAN DESIGN AND SPECIFICATIONS AND THE SOILS B. CONSTRUCTION OF ALL STREET AND UTILITY IMPROVEMENTS SHALL CONFORM TO THE WAUKEE STANDARD BE REPAIRED TO THE UTILITY OWNER'S SPECIFICATIONS AT THE CONTRACTOR'S EXPENSE. REMOVAL OR MODIFICATION. ANY DAMAGES TO UTILITY ITEMS NOT SHOWN FOR REMOVAL OR MODIFICATION SHALL EXACT LOCATION, AND DEPTH OF ALL UTILITIES. PROTECT ALL UTILITY LINES AND STRUCTURES NOT SHOWN FOR PROVIDERS AS NECESSARY DURING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXISTENCE, A. NOTIFY UTILITY PROVIDERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES AND COORDINATE WITH UTILITY BUILDING DESCRIPTION BUILDING CONSTRUCTION TYPE: TOTAL = 13,516 SF LEASE = 3,436 SF OFFICE = 10,080 SFBUILDING SF: HEIGHT: 24'-0" HH HH BICYCLE RACK BENCH BENCHBENCH 8" W 8" W8" WST ST ST STST8" SAN9 9 97 10 7 10 10 FUTURE STALLS FUTURE STALLS ROOM FIRE RISER 10 T HGAS30' Ingress/Egress Easement (BOOK 2019, PAGE 21469) Easement Storm Sewer75.22'38' 276.70'N0°11'20"E 271.19'M&R276.70'44.24' 15'15'S0°11'20"W 271.19'75,039 SF LOT 1 PT LOT 2 30' Ingress/Egress Easement (BOOK 2019, PAGE 21469) Existing 10' Sanitary Sewer Easement (BOOK 2019, PAGE 21469) Existing 10' Public Utility Easement (BOOK 2019, PAGE 21469) COVE AT KETTLESTONE PLAT 2 Easement 30' Ingress/Egress PT LOT 2 48,002 SF LOT 2 LOT 1(BOOK 2019, PAGE 21469)COVE AT KETTLESTONE PLAT 2(BOOK 2019, PAGE 21469) Existing 10' Public Utiltiy Easement 21469) (BOOK 2019, PAGE Easement 20' Ingress/Egress 80' Temporary Grading Easement Detention Easement 1"= 120.0504KMMEDCRMM120.050488WAUKEE, IOWA BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= ZARNESONV:\Projects\2020\120.0504.01\CADD\SP_1200504_03DIM.dgn7/22/20205:05:29 PMSnyder1:20Y:\pen\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS06/23/20RMM6/09/2020ELITE EYE CARE - WAUKEE2REVISED AS PER CITY COMMENTS07/07/20RMM3REVISED AS PER CITY COMMENTS07/22/20RMMC C Concrete Sidewalk F.L.=1055.46 15" CPP W F.L.=1055.51 12" PVC S Rim=1057.96 Concrete 12" PVC N F.L.=1056.77 Concrete Sidewalk Inv=1038.62 8" PVC W Inv=1038.72 8" PVC E Rim=1061.17 SE BISHOP DR Concrete Concrete SE UNIVERSITY AVE Inv=1040.39 8" PVC W Inv=1040.49 8" PVC E Rim=1059.69 CP3 BM1BM2 8" 8" 8" 8" DIMENSION PLAN CONSTRUCTION NOTES NO SCALE VARIES1"R 4.5" 7.5" 2"R 6"PCC STANDARD CURB PCC SIDEWALK W/ INTEGRAL CURB 6" NO SCALE 12"18" VARIES SIDEWALK 6 7 4 2 3 height: 0" to 2" Drop curb 1'-0" min. Curb opening 18"12" Driveway width NO SCALE3 1 DIMENSION PLAN3 35 DETAIL B 2 7Back of curb 1 R bar reinforcing #5 x 36" 1'-0" TYPICAL SECTION Curb Driveway SidewalkPr o pert y line TYPE A WITH RADII as specified Detail B Refer to curb Back of 8 2 'E' joint joint 'C' or 'E' 'B' joint 'C' joint 9 10 10 1'-0" CONCRETE DRIVEWAY, TYPE A detectable warning panel with Engineer. Figure 7030.205; verify need for change requires a curb ramp, comply with sidewalk through driveway. If elevation transition from existing sidewalk to exceeds 2.0%, remove and replace to If cross slope of adjacent sidewalk panel passing space. driveway 5 feet wide to serve as a construct the sidewalk through the specified in the contract documents, maximum cross slope of 2.0%. If Target cross slope of 1.5% with a 2% toward center of alley. For alleys, invert the pavement crown 'B' joint is specified. Provide 'E' joint at back of curb unless 10 9 8 7 6 5 4 3 2 1 8 inches minimum. Match thickness of adjacent roadway, pavement. Center reinforcing bar vertically in the match thickness of driveway. Sidewalk thickness through driveway to minimum. Commercial and industrial: 7 inches Residential: 6 inches minimum. Pavement thickness. across sidewalk. of sidewalk. Do not extend raised curb end of taper/radius or at the front edge Transition the curb height to 0 inches at specified in the contract documents. Commercial and industrial: As maximum. Residential: 10 foot minimum,15 foot Driveway radius (R). 7" PCC PAVEMENT 6" PCC PAVEMENT 4" PCC SIDEWALK 20'0 20 FEET 3 1 3 2 9" PCC PAVEMENT 10.0'15.1'19.0'34.1'25.0' B/BTYP19.0'6.0'5.2'TYP 9.0' 10.0'96.3'70' ROW MAINTENANCE OF THE SANITARY SEWER. EXISTING SANITARY SEWER EASEMENT IF PAVEMENT NEEDS TO BE REMOVED FOR 8. THE CITY OF WAUKEE IS NOT RESPONSIBLE FOR PAVEMENT REPLACEMENT WITHING ARCHITECTURAL PLANS PRIOR TO CONSTRUCTION. E. SCREEN WALL. COORDINATE EXACT LOCATION AND DIMENSIONS WITH D. BIKE RACK LOCATION. COORDINATE WITH OWNER. C. BENCHES. COORDINATE WITH OWNER. DETAILS. B. MONUMENT SIGN. BY OTHERS. SEE ARCHITECTURAL AND ELECTRICAL PLANS FOR A. TRASH ENCLOSURES. 7. SITE AMENITIES, PROVIDE THE FOLLOWING: WAUKEE, AND OWNER PRIOR TO CONSTRUCTION. C. COORDINATE RELOCATION OF LIGHT POLE WITH UTILITY PROVIDER, CITY OF CONSTRUCTION. COORDINATE WITH THE OWNER ALL ASPECTS SITE LIGHTING PRIOR TO B.SITE LIGHTING SHOWN IS FOR ILLUSTRATION PURPOSES ONLY. CONTRACTOR TO ALL ASPECTS OF ELECTRICAL SERVICE. A.CONTRACTOR TO COORDINATE WITH THE UTILITY OWNER AND PROPERTY OWNER 6. SITE LIGHTING, PROVIDE THE FOLLOWING: A. PROVIDE VAN ACCESSIBLE PARKING SIGNAGE AS PER ADAAG REQUIREMENTS. 5. SIGNS, PROVIDE THE FOLLOWING: C. ACCESSIBLE AISLE. 45° STRIPING AT 3' ON CENTER SPACING WHERE SHOWN. B. PAINTED STATE OF IOWA APPROVED ACCESSIBLE PARKING SYMBOL. A. 4" WIDE PAINTED PARKING STALL LINES. 4. PAVEMENT MARKINGS, PROVIDE THE FOLLOWING: H. TAPER TO NO CURB IN 6'. SPECIFICATIONS. G. 9" DEPTH PCC ENTRANCE APPROACH TO BE CONSTRUCTED AS PER STANDARD MEETS VEHICULAR TRAFFIC. DETECTABLE WARNING SYSTEM AT RAMPS WHERE PEDESTRIAN TRAFFIC PEDESTRIAN RAMP WITH A MAXIMUM SLOPE OF 8.33%. PROVIDE F. E. INTEGRAL CURB. D. STANDARD CURB. C. PCC SIDEWALKS, 4" DEPTH PAVEMENT. COMPACTED TO 95% STANDARD PROCTOR DENSITY. B. PCC DRIVES, 7" DEPTH PAVEMENT ON 12" DEPTH PREPARED SUBGRADE COMPACTED TO 95% STANDARD PROCTOR DENSITY. A. PCC PARKING, 6" DEPTH PAVEMENT ON 12" DEPTH PREPARED SUBGRADE 3. PAVEMENTS, PROVIDE THE FOLLOWING: D. REMOVE AND DISPOSE OF EXISTING STORM SEWER. UTILIY PROVIDER PRIOR TO CONSTRUCTION. C. REMOVE AND RELOCATE COMMUNICATION BOX. COORDINATE WITH OWNER AND B. SAWCUT FULL DEPTH PCC, REMOVE AND DISPOSE OF EXISTING PCC. A. GRIND CURB. 2. DEMOLITION, REMOVE THE FOLLOWING: OWNER'S SPECIFICATION. CONTRACTORS EXPENSE WITH WORK BEING PREFORMED TO THE UTILITY NOT SCHEDULED FOR MODIFICATION OR DEMOLITION SHALL BE REMEDIED AT THE B. PROTECT EXISTING UTILITIES, ANY DAMAGE TO THE EXISTING UTILITIES THAT ARE A. PAVEMENTS TO REMAIN. 1. EXISTING FEATURES, PROTECT THE FOLLOWING: 15.0'R 15.0' R 5.0'R15.0'R 15.0'R5.0'R 25.0' B/B 5.1'20.0' TYP 9.0' TYP 9.0' 9.0'9.0'9.0'9.0'9.0'9.0'15.0'15.0'5.0' 11.1' 7.5'8.5'5.0'11.8'B/B 25.0' 19.0' TYP 6.0' 6.9'9.0'6.0'19.0' TYP25.0' B/B19.0' TYP7.0'7.0'6.0'6.0'10.0' 10.0' 5.5' 6.0'5.0'5.0'5.0'5.0'6.0' 5.0'R13.6' R 5.0'5.5'18.5'13.5'5.0' 19.0'15.0'R5 .0 'R77.0' 25.0' B/B 2 5.0'R 25.0'R55.1'12.0'70.0' ROW31.0' B/B37.2'25.0'120.0' ROW14.4'39.7'23.1'11.7'14.3'20.1'25.2'20.1'14.3'39.2'112.8'24.9'25.3'4.0'15.0'1A 1A 1A 1A 1A 1A 1A 1A 1B 1B 1B 1B1B 1B 1B 1B 1B 1B 1B 2A2A 2A 2A 2B 3B 3A 3A 3A 3A 3A 3A 3A 3B 3B 3B 3B 3B 3C 3C 3C 3C 3C 3C 3C 3C3C 3D 3D 3D 3D 3D 3D3D 3D 3E 3E 3E 3E 3E3E 3F 3F 3F 3F 3F 3F 3F 3F 4A TYP 4A TYP 4A TYP TYP 4A TYP 4A 4C 4B 4B4C 7A 5A 5A 5A 7D 3F 7C 2D 3D 3D 2C 2D 6C 3G 9" PCC 7" PCC 7" PCC 7" PCC 7" PCC 7" PCC7" PCC 6" PCC 6" PCC 6" PCC 6" PCC 6" PCC 6" PCC 6" PCC 3H PATIO DRIVEWAY (7030.101) SUDAS TYPE A 7B HH HH BICYCLE RACK BENCH BENCHBENCH 8" W 8" W8" W9 9 97 10 7 10 10 FUTURE STALLS FUTURE STALLS ROOM FIRE RISER 10 T HGASAL=25.16 30' Ingress/Egress Easement (BOOK 2019, PAGE 21469) Easement Storm Sewer75.22'38' 276.70'N0°11'20"E 271.19'M&R276.70'44.24' 15'15'S0°11'20"W 271.19'75,039 SF LOT 1 PT LOT 2 30' Ingress/Egress Easement (BOOK 2019, PAGE 21469) Existing 10' Sanitary Sewer Easement (BOOK 2019, PAGE 21469) Existing 10' Public Utility Easement (BOOK 2019, PAGE 21469) COVE AT KETTLESTONE PLAT 2 Easement 30' Ingress/Egress PT LOT 2 48,002 SF LOT 2 LOT 1(BOOK 2019, PAGE 21469)COVE AT KETTLESTONE PLAT 2(BOOK 2019, PAGE 21469) Existing 10' Public Utiltiy Easement 21469) (BOOK 2019, PAGE Easement 20' Ingress/Egress 172.33' AL=91 .98 ' C -4 80' Temporary Grading Easement Detention Easement 1"= 120.0504KMMEDCRMM120.050488WAUKEE, IOWA BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= ZARNESONV:\Projects\2020\120.0504.01\CADD\SP_1200504_04UTL.dgn7/22/20205:05:30 PMSnyder1:20Y:\pen\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS06/23/20RMM6/09/2020ELITE EYE CARE - WAUKEE2REVISED AS PER CITY COMMENTS07/07/20RMM3REVISED AS PER CITY COMMENTS07/22/20RMMC C Concrete Sidewalk F.L.=1055.46 15" CPP W F.L.=1055.51 12" PVC S Rim=1057.96 Concrete 12" PVC N F.L.=1056.77 Concrete Sidewalk Inv=1038.62 8" PVC W Inv=1038.72 8" PVC E Rim=1061.17 SE BISHOP DR Concrete Concrete SE UNIVERSITY AVE Inv=1040.39 8" PVC W Inv=1040.49 8" PVC E Rim=1059.69 CP3 8" 8" 8" 8" 1056 1057105810591060 10601060106010601 061 1061 1061 10611061 10611061 106110611061 1062 1062 1062 106210621062 106210621062 20'0 20 FEET 4 UTILITY PLAN4UTILITY PLAN CONSTRUCTION NOTES TESTED AND DECHLORINATED. E. ALL WATERMAIN SHALL BE PRESSURE AND BACTERIA D. ALL SANITARY MANHOLES TO BE VACUUM TESTED. MANHOLES SHALL BE VACUUM TESTED. SHALL BE PROVIDED TO THE CITY OF WAUKEE. ALL SANITARY SEWER ALL CLEANING AND TELEVISING. COPIES OF THE REPORT AND VIDEO TELEVISED PRIOR TO PAVING. THE CITY OF WAUKEE SHALL WITNESS C. ALL SANITARY SEWER AND STORM SEWER SHALL BE CLEANED AND DEPARTMENT. TIE-INS SHALL BE WITNESSED BY THE CITY OF WAUKEE ENGINEERING SPECIFICATION FOR PUBLIC IMPROVEMENTS AND ANY TESTING OR B. ALL UTILITIES SHALL BE TESTED TO THE CITY OF WAUKEE STANDARD CONNECTING TO ANY PUBLIC UTILITY. A. NOTIFY THE CITY OF WAUKEE AT LEAST 48 HRS PRIOR TO GENERAL CONSTRUCTION NOTES NO SCALE4 1 FL=1058.37 (OUT W) RIM=1061.12 ST-4, TYPE SW-511 128LF of 15"RCP @ 0.5% FL=1057.63 (OUT NW) FL=1057.73 (IN E) RIM=1060.84 ST-5, TYPE SW-511 146LF of 15"RCP @ 0.5%FL=1056.33 (OUT SW) FL=1056.43 (IN E) RIM=1059.85 ST-3, TYPE SW-511 FL=1056.06 GUARD FOOTING & APRON ST-3A, 18" FES W/ INV=1039.51 2C TP=1055.22(SAN) BP=1058.13(ST) TP=1055.12(WAT) BP=1058.12(ST) 2B FL=1055.51 INTAKE CONNECT TO EX. 54 LF of 15" R CP @ 0.5 %6. TRANSFORMER LOCATION. COORDINATE WITH OWNER AND FRANCHISE UTILITY PROVIDER. SEPARATION. 5. CRITICAL CROSSING. CONTRACTOR TO VERIFY ALL CROSSINGS AND PROVIDE 18" MINIMUM COORDINATE UTILITY CONNECTIONS ACCORDINGLY. MECHANICAL PLANS FOR INTERIOR UTILITY ROUTING, METERS, DESIGN INFORMATION AND UTILITY SERVICE PROVIDER PRIOR TO CONSTRUCTION. SEE ARCHITECTURAL AND 4. COORDINATE NATURAL GAS AND ELECTRICAL SERVICES AND METER LOCATION WITH G. 2" VALVE F. 6" VALVE E. REMOTE FIRE DEPARTMENT CONNECTION. COORDINATE WITH MECHANICAL PLANS. CONSTRUCTION. D. CONNECT TO EXISTING. CONTRACTOR TO VERIFY LOCATION AND DEPTH PROIR TO MECHANICAL PLANS PRIOR TO CONSTRUCTION. C. BUILDING WATER SERVICE CONNECTION. VERIFY LOCATION AND DEPTH WITH B. 2" DOMESTIC WATER SERVICE A. 8" WATER SERVICE LINE. 3. WATER SERVICES, PROVIDE THE FOLLOWING: ELEVATION PRIOR TO CONSTRUCTION. USE 1:1 RISER AS NECESSARY. D. CONNECT TO EXISTING 8" SANITARY SEWER. CONTRACTOR TO VERIFY LOCATION AND C. SANITARY SEWER CLEANOUT. MECHANICAL PLANS PRIOR TO CONSTRUCTION. B. CONNECT TO BUILDING SANITARY SERVICE. VERIFY LOCATION AND ELEVATION WITH A. 6" SANITARY SEWER SERVICE LINE @ MINIMUM 1.0% 2. SANITARY SEWER SERVICES; PROVIDE THE FOLLOWING: SPECIFICATION. CONTRACTORS EXPENSE WITH WORK BEING PERFORMED TO THE UTILITY OWNER'S SCHEDULED FOR MODIFICATION OR DEMOLITION SHALL BE REMEDIED AT THE A. PROTECT EXISTING UTILITES, ANY DAMAGE TO THE EXISTING UTILITIES THAT ARE NOT 1. EXISTING FEATURES, PROTECT THE FOLLOWING: INV=1055.75 @ 2.0%6" PVC97 LF OF3F3G 12" STORM SEWER REMOVE EXISTING 3B 3D 3C FFE=1062.25 FL=1057.36 GUARD FOOTING & APRON ST-5A, 15" FES W/ EXISTING 150' R HYDRANT COVERAGE EXISTING 150' R HYDRANT COVERAGEPROPOSED 150' R HYDRANT COVERAGECONCRETE FOOTING 3" 1'-8"3'-6"6" RESTRICTOR PLATE FOR SIZES SECTION, SEE PLAN RCP FLARED END 5/8" HOLES SECTION VIEW END VIEW 3'-6"VARIES TO MATCH WIDTH OF END SECTION FOOTING CONCRETE 1/2" BOLTS HOLES FOR DRILL 5/8" ORIFICE PLATE DETAIL ORIFICE PLATE. 1/4" STAINLESS STEEL ORIFICE PLATE. BOLT. WELD TO WITH 5/8 " HOLE FOR 1/2" 3" x 3" x 3" x 1/4" ANGLE89LF of 12"RCP @ 0.45% TRENCHLESS METHOD INSTALLED VIA WATER SERVICE TO BE TP=1040.19(EX SAN) BP=1055.12(WAT) ST-5=4-13/16" Dia. ST-5=4-13/16" Dia. 3E FL=1057.61 (OUT NW) RIM=1060.25 ST-1, TYPE SW-511 70LF of 15"RCP @ 0.5 %FL=1057.16 (OUT W) FL=1057.26 (IN SE) RIM=1060.58 ST-2, TYPE SW-511 55LF of 18"RCP @ 0.5%FL=1055.91 ORIFICE PLATE GUARD & 5-1/8"" FOOTING & APRON ST-6, 12" FES W/ 4 (4' x 5' x 1.5') RIP-RAP CLASS-D 10 TONS OF (4' x 5' x 1.5') RIP-RAP CLASS-D 10 TONS OF 2D 2A 3A 55 1A 1A 5 6 4 4 HH HH BICYCLE RACK BENCH BENCHBENCH 8" W 8" W8" WST ST ST STST8" SAN9 9 97 10 7 10 10 FUTURE STALLS FUTURE STALLS ROOM FIRE RISER 10 HAL=25.16 30' Ingress/Egress Easement (BOOK 2019, PAGE 21469) Easement Storm Sewer75.22'38' 276.70'N0°11'20"E 271.19'M&R276.70'44.24' 15'15'S0°11'20"W 271.19'75,039 SF LOT 1 PT LOT 2 30' Ingress/Egress Easement (BOOK 2019, PAGE 21469) Existing 10' Sanitary Sewer Easement (BOOK 2019, PAGE 21469) Existing 10' Public Utility Easement (BOOK 2019, PAGE 21469) COVE AT KETTLESTONE PLAT 2 Easement 30' Ingress/Egress PT LOT 2 48,002 SF LOT 2 LOT 1(BOOK 2019, PAGE 21469)COVE AT KETTLESTONE PLAT 2(BOOK 2019, PAGE 21469) Existing 10' Public Utiltiy Easement 21469) (BOOK 2019, PAGE Easement 20' Ingress/Egress 172.33' AL=91 .98 ' C -4 80' Temporary Grading Easement Detention Easement 1"= 120.0504KMMEDCRMM120.050488WAUKEE, IOWA BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= ZARNESONV:\Projects\2020\120.0504.01\CADD\SP_1200504_05GRA.dgn7/22/20205:05:31 PMSnyder1:20Y:\pen\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS06/23/20RMM6/09/2020ELITE EYE CARE - WAUKEE2REVISED AS PER CITY COMMENTS07/07/20RMM3REVISED AS PER CITY COMMENTS07/22/20RMMC C Concrete Sidewalk F.L.=1055.46 15" CPP W F.L.=1055.51 12" PVC S Rim=1057.96 Concrete 12" PVC N F.L.=1056.77 Concrete Sidewalk Inv=1038.62 8" PVC W Inv=1038.72 8" PVC E Rim=1061.17 SE BISHOP DR Concrete Concrete SE UNIVERSITY AVE Inv=1040.39 8" PVC W Inv=1040.49 8" PVC E Rim=1059.69 CP3 BM2 8" 8" 8" 8" 1057 1058105810581059 1059 1059105910591059106010601060 10601060106010601060106010611061 1061 1061 10611062 1061.41 1060.36 1060.41(1059.46) (1059.37) 1056 10571058(1058.95)1059(1059.30)(1059.54) 1059.75 1059.79 1059.851060 10601060106010601060.53TC) (1060.03G 1060.051061.07 1060.59TC 1060.09G 1060.09 1060.17 1060.21 (1060.24) (1060.32) 1060.82TC 1060.32G 1060.381060.38 1060.41 OVERFLOW 1060.41 1060.42 1060.93TC) (1060.43G 1060.47 1060.99TC 1060.49G 1060.95G 1061.06TC 1060.56G 1060.58 1061.11TC 1060.61G 1060.631060.63 (1060.65) 1060.751061.29TC 1060.79G (1060.80) (1060.81)1059.95 1060.83 1061.45TC 1060.95G1060.85 1061.36TC 1060.86G 1060.88 1060.89 1060.91 1060.95 1060.471060.971061 1061 1061 10611061 10611061 1061.001061 10611061 1061.01 1060.42 1061.06 1061.57TC 1061.07G 1061.60TC 1061.10G HP 1061.10 1061.12 1061.63TC 1061.13G 1061.13 1061.15 1061.20 1061.70TC 1061.20G 1061.72TC 1061.22G1061.221061.78TC 1061.28G 1061.28 1061.31 1061.85TC 1061.35G 1061.85TC 1061.35G1061.35 1061.41 1061.41 1061.41 1061.41 1061.41 1061.41 1061.41 1061.41 1061.41 1061.41 1061.42 1061.43 1061.95TC 1061.45G 1061.98TC 1061.48G 1061.48 1061.99TC 1061.49G 1061.01 1061.51 1061.51 1061.511061.411062.08TC1061.58G1062.09TC 1061.59G 1061.92TC 1061.42G 1060.921060.83 1062.13TC 1061.63G 1061.641061.651062.20TC 1061.70G 1062.20TC 1061.70G1062.21TC1061.71G 1062.21TC 1061.71G 1061.721061.75 1062.36TC 1061.76G 1061.80 1062.31TC 1061.81G 1061.83 1060.84 1061.85TC1061.35G 1062.40TC 1061.90G 1062.45TC 1061.95G 1062 1062 1062 106210621062 1062106210621062.25FFE1062.00FG 1062.53TC 1062.03G 1062.09TC 1061.59G 1062.65TC 1062.15G 1062.21TC1061.71G 1062.25 1062.251062.25 1062.95TC 1062.45G 20'0 20 FEET 5 5GRADING PLAN GENERAL NOTES GRADING PLANFFE=1062.25 ELEVATION=1060.35 100-YEAR PONDING ELEVATION=1061.02 100-YR PONDING ELEVATION=1061.33 100-YR PONDING ELEVATION=1060.79 100-YR PONDING ELEVATION=1060.07 100-YR PONDING W/15" MIN. OVERLAP 4-#4 LONGITUDINAL REBAR CLEARANCE2"2% M IN .SLOPE 6" NOTES SUBGRADE 6" COMPACTED 6"1"2% MIN.SLOPE 5'-0" O.C. (3'-6" LONG) #4 TRAVERSE REBAR @ 6. TAPER WIDTH TO MATCH FLARED END SECTION WIDTH AS NECESSARY. 5. REBAR SHALL BE EPOXY COATED STEEL AS PER SUDAS. 4. CURING AS SPECIFIED FOR CONCRETE PAVEMENT IN SUDAS. 3. FINISH SHALL CONFORM TO SUDAS FOR SIDEWALKS AND PROVIDE FINAL BROOM FINISH. CONSTRUCTION. PLACE TOPSOIL OVER ALL AREAS DISTURBED. 2. CONCRETE WILL HAVE THE MIX DESIGN AS SHOWN FOR STREET PAVEMENT IN THE ROADSTONE BASE. 1. SUBGRADE SHALL CONSIST OF A FIRM UNYIELDING CLAY (CL OR CH) OR CLASS "A" NO SCALE 4"4'-0" PCC CUNETTE 5 12.0%MIN2.0%MIN2.0%MIN2.0%MIN2.0%MIN 2.0%MIN 1061.35 ST-4 OVERFLOW 1061.51 ST-3 OVERFLOW 1061.06 ST-1 OVERFLOW1060.59ST-2 OVERFLOW2.0%MIN 4:14:1 4:14:14:12.0%MIN2.0%MIN1061.85TC 1061.35G G. SLOPES OF ALL UNPAVED AREAS TO BE 2.0% MINIMUM. A RAIN EVENT. CONSTRUCTION ACTIVITIES BY THE END OF THE WORK DAY AND PRIOR TO FROM STREETS, DRIVEWAYS, AND SIDEWALKS CAUSED BY F. THE CONTRACTOR IS RESPONSIBLE FOR CLEANING DIRT AND DEBRIS CUT OR FILLED. RESPREAD TO MINIMUM 8" DEPTH TO FINISH GRADES. E. CONTRACTOR TO STRIP AND STOCKPILE TOPSOIL FROM ALL AREAS TO BE SECTION. STRUCTURE TO CENTER OF STRUCTURE AND INCLUDE FLARED END D. ALL STORM SEWER PIPE LENGTHS ARE MEASURED FROM CENTER OF NOTED. GRADES AND/OR TOP OF PAVING SLAB (GUTTER), UNLESS OTHERWISE C. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS SHOWN ARE FINISHED RELOCATIONS WITH UTILITY PROVIDER. CONTRACTOR'S EXPENSE. COORDINATE ANY UTILITY CONTRACTOR'S CARELESSNESS SHALL BE CORRECTED AT THE AND SERVICES DURING CONSTRUCTION. ANY DAMAGE DUE TO THE LOCATION AND DEPTH OF ALL UTILITIES. AVOID DAMAGE TO UTILITIES CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXISTENCE, EXACT B. NOTIFY UTILITY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION. LOCATION INDICATED. DOES NOT WARRANT THAT THE UTILITIES SHOWN ARE IN THE EXACT IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEY FURTHER GUARANTEE THAT THE UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES INFORMATION AND/OR RECORDS OBTAINED. THE SURVEYOR MAKES NO THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY A. UTILITY WARNING: ELEVATION=1060.39 100-YR PONDING ELEVATION=1058.03 100-YR PONDING 1059.50EX-ST OVERFLOW HH HH BICYCLE RACK BENCH BENCHBENCH 8" W 8" W8" WST ST ST STST8" SAN9 9 97 10 7 10 10 FUTURE STALLS FUTURE STALLS ROOM FIRE RISER 10 H30' Ingress/Egress Easement (BOOK 2019, PAGE 21469) Easement Storm Sewer75.22'38' 276.70'N0°11'20"E 271.19'M&R276.70'44.24' 15'15'S0°11'20"W 271.19'75,039 SF LOT 1 PT LOT 2 30' Ingress/Egress Easement (BOOK 2019, PAGE 21469) Existing 10' Sanitary Sewer Easement (BOOK 2019, PAGE 21469) Existing 10' Public Utility Easement (BOOK 2019, PAGE 21469) COVE AT KETTLESTONE PLAT 2 Easement 30' Ingress/Egress PT LOT 2 48,002 SF LOT 2 LOT 1(BOOK 2019, PAGE 21469)COVE AT KETTLESTONE PLAT 2(BOOK 2019, PAGE 21469) Existing 10' Public Utiltiy Easement 21469) (BOOK 2019, PAGE Easement 20' Ingress/Egress 172.33' 80' Temporary Grading Easement Detention Easement 1"= 120.0504KMMEDCRMM120.050488WAUKEE, IOWA BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= ZARNESONV:\Projects\2020\120.0504.01\CADD\SP_1200504_06ERO.dgn7/22/20205:05:32 PMSnyder1:20Y:\pen\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS06/23/20RMM6/09/2020ELITE EYE CARE - WAUKEE2REVISED AS PER CITY COMMENTS07/07/20RMM3REVISED AS PER CITY COMMENTS07/22/20RMMC C Concrete Sidewalk F.L.=1055.46 15" CPP W F.L.=1055.51 12" PVC S Rim=1057.96 Concrete 12" PVC N F.L.=1056.77 Concrete Sidewalk Inv=1038.62 8" PVC W Inv=1038.72 8" PVC E Rim=1061.17 SE BISHOP DR Concrete Concrete SE UNIVERSITY AVE Inv=1040.39 8" PVC W Inv=1040.49 8" PVC E Rim=1059.69 CP3 BM1BM2 8" 8" 8" 8" 1057 105810581059 10591059 10591059106010601060 10601060106010601060106010611061 1061 1061 10611062 1056 1057105810591060 10601060106010601061 1061 1061 10611061 10611061 106110611061 1062 1062 1062 106210621062 106210621062 20'0 20 FEET 66 EROSION AND SEDIMENT CONTROL PLANSTORMWATER MANAGEMENT QUANTITIES ATTACHMENT TO POST Fabric Post cable ties Wire or 5 TYPICAL SILT FENCE DITCH CHECK F o resl opeVariable (20' for a normal 10' wide ditch.) (5'-0" max.) Post spacing (5'-0" max.) Post spacing 4 5 1 3 Backslope 902 904 906 908 910 TYPICAL SILT FENCE INSTALLATION ON LONGITUDINAL SLOPES individual section of silt fence Install "J-hook" at each end of an ground contour Install parallel to (Plan View) (600' if slope is flatter than 5%) 200' max. length per section documents or as directed by the Jurisdictional Engineer. Section 9040, 3.07 and at locations shown in the contract Install silt fence according to the requirements of GENERAL NOTES: 1 2 3 4 5 Insert 12 in. of fabric a minimum of 6 in. deep (fabric may be folded below the ground line) Compact ground by driving along each side of the silt fence as required to sufficiently secure the fabric in the trench to prevent pullout and flow under the fence. In ditches, extend silt fence up side slope so the bottom elevation at the end of the fence is a minimum of 2 in. higher than the top of the fence in the low point of the ditch. Steel posts to be embedded 20 in. unless otherwise allowed by the Jurisdictional Engineer. Secure top of engineering fabric to steel posts using wire or plastic ties (50 lb. min.). See details of "Attachment to Posts." TYPICAL SILT FENCE INSTALLATION ON LONGITUDINAL SLOPES Ground line Fabric Flow 4'-0" minimum 'T' steel fence post (Profile View) 4 1 1 2 See plans for spacing NO SCALE SILT FENCE DETAIL Ground line Fabric 1 5 4 or as required to adequately support fence Reduce post spacing to 5'-0" at water concentration areas, 8'-0"spacing 24"DETAILS OF SILT FENCE ON LONGITUDINAL SLOPES36"6 1 ENTRANCE STABILIZED CONSTRUCTION PROPERTY OWNER) (COORDINATE WITH STAGING AREA LOCATION WITH PROPERTY OWNER) (COORDINATE SIZE AND LOCATION APPROXIMATE STOCKPILE FFE=1062.25 2.09 AC DISTURBED AREA WASHOUT CONCRETE Q=1.41 CFS TO WALNUT CREEK EXISTING STORM SEWER ULTIMATE DISCHARGE TO 2.09 ACDISTURBED AREA 0.29 ACSOD 0.17 ACDETENTION BASIN SEEDING 0.13 ACSUDAS TYPE 4 SEEDING, FERTILIZING & MULCHING 9 EASEDIMENT BASKETS 988 LFSILT FENCE BASKET SEDIMENT BASKET SEDIMENT BASKET SEDIMENT BASKET SEDIMENT BASKET SEDIMENT BASKET SEDIMENT BASKET SEDIMENT BASKET SEDIMENT BASKET SEDIMENT BASKET SEDIMENT BASKET SEDIMENT BASKET SEDIMENT BASKET SEDIMENT (TYP.) SILT FENCE BICYCLE RACK BENCH BENCHBENCH 10 1"= 120.0504KMMEDCRMM120.050488WAUKEE, IOWA BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= ZARNESONV:\Projects\2020\120.0504.01\CADD\SP_1200504_07DTL.dgn7/22/20205:05:33 PMSnyder1:10Y:\pen\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS06/23/20RMM6/09/2020ELITE EYE CARE - WAUKEE2REVISED AS PER CITY COMMENTS07/07/20RMM3REVISED AS PER CITY COMMENTS07/22/20RMM10 7 10 9H BICYCLE RACK BENCH BENCHBENCH 9 9 97 10 7 10 10 FUTURE STALLS FUTURE STALLS ROOM FIRE RISER 10 77 SIDEWALK RAMP DETAILS10'SE UNIVERSITY AVE 7 1 SCALE: 1"=10' SIDEWALK RAMP AREA 1 DETAIL 7 2 SCALE: 1"=10' SIDEWALK RAMP AREA 2 DETAIL 7 3 SCALE: 1"=10' SIDEWALK RAMP AREA 3 DETAIL 7 4 SCALE: 1"=10' SIDEWALK RAMP AREA 4 DETAIL 7 6 SCALE: 1"=50' SITE MAP DETAIL RAMP AREA 3 RAMP AREA 4 RAMP AREA 2 RAMP AREA 1 RAMP AREA 5 7 5 SCALE: 1"=10' SIDEWALK RAMP AREA 5 DETAIL 1060.36 1060.41 1060.45 1060.41 1060.09 1060.051060.911061.001061.091061.181061.60TC 1061.10G 1061.95TC 1061.45G 1061.75 1062.05 1061.19 1061.28 1061.29 1061.38 1061.78TC 1061.28G 1059.75 1059.79 1060.14 1060.20 1060.14 1060.09 (1059.54)(1059.30)(1059.42)1061.421061.311061.85 1061.85 1061.78 1061.781061.061060.971061.511061.511061.571061.57 1061.75 1061.67 1061.62 1061.671061.041061.071061.011060.981060.471060.421061.99TC 1061.49G 1061.63TC 1061.13G 1060.83 1060.92 1060.74 1061.01 1061.20 1061.20 1061.30 1061.30 1061.90TC 1061.40G 1062.00 1061.95 1061.85TC 1061.35G 1061.651061.721062.191062.191062.251062.251061.511061.431061.83 1061.75 1061.701061.751061.591061.591061.651061.651061.65 1061.591061.591061.651061.411061.511061.351061.281061.46 1061.46 1061.69 1061.00 1061.52 1061.70TC 1061.20G 1061.691.23%2.46%1.33% 0.00%1.20%1.83%6.66%8.30%0.00%1.40%1.23%0.00%2.77%1.66%1.20% 1.16%8.30%7.23%0.00%1.20%1.50%6.92%8.30%0.00%1.20%8.00% 8.00%0.80%1.20%0.80%0.80%1.20% 0.80%0.67%0.83%1.00% 4.37%0.76%5.47%0.76%4.99% 5.94%1.20%1.00%1.20% 1.00%0.00%1.67% 1.67% 1.47% 1.79% 1.95% 3.47% 6.50% 6.50%1.67%1.67%1.67%1.26%1.42%4.56% 4.56%1.67%3.00%1.83%1.16% 0.00%1.20%0.00% 0.00%1.40%0.00%1.20%1.20%0.00%0.00%1.20%0.00%1.67%3.03%1.00%2.41%1060.521060.491061.45TC 1060.95G 1059.94 1059.89 0.16%1061.581061.57 1.66%1061.241060.141.0%1.0%1.0%1.11%1.0% 1.0%1.0%1.67%8.0%8.0%7.2%7.2%1.0%1.0%1.0%7.18% 8.23% HH HH BICYCLE RACK BENCH BENCHBENCH 8" W 8" W8" WST ST ST STST8" SAN9 9 97 10 7 10 10 FUTURE STALLS FUTURE STALLS ROOM FIRE RISER 10 H30' Ingress/Egress Easement (BOOK 2019, PAGE 21469) Easement Storm Sewer75.22'38' 15'15' 75,039 SF LOT 1 30' Ingress/Egress Easement (BOOK 2019, PAGE 21469) Existing 10' Sanitary Sewer Easement (BOOK 2019, PAGE 21469) Existing 10' Public Utility Easement Easement 30' Ingress/Egress 48,002 SF LOT 2 (BOOK 2019, PAGE 21469) Existing 10' Public Utiltiy Easement 21469) (BOOK 2019, PAGE Easement 20' Ingress/Egress 80' Temporary Grading Easement Detention Easement 1"= 120.0504KMMEDCRMM120.050488WAUKEE, IOWA BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= ZARNESONV:\Projects\2020\120.0504.01\CADD\SP_1200504_08LND.dgn7/22/20205:05:36 PMSnyder1:20Y:\pen\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS06/23/20RMM6/09/2020ELITE EYE CARE - WAUKEE2REVISED AS PER CITY COMMENTS07/07/20RMM3REVISED AS PER CITY COMMENTS07/22/20RMMC C CP3 SE UNIVERSITY AVE SE BISHOP DR Concrete Concrete Sidewalk Concrete Concrete Sidewalk Concrete 1057 1058105810591059 10591059106010601060 10601060106010601060106010611061 1061 1061 10611062 1056 1057105810591060 1060106010601 061 1061 1061 10611061 10611061 106110611061 1062 1062 1062 106210621062 106210621062 20'0 20 FEET 8 8PLANTING PLANPLANTING PLAN GENERAL NOTES LANDSCAPE REQUIREMENTS AND CALCULATIONS BOTANICAL NAMEKEY SHRUBSSIZE COMMENTS B&B AG AUTUMN BRILLANCE SERVICEBERRYAmelanchier x grandiflora 'Autumn Brilliance' B&B B&B PLANT SCHEDULE CONT. (6' O.C.)36" Ht. COMMON NAME TREES18" Ht. 24" Ht. AT GB TREESUNDERSTORYPhysocarpus opulifolius 'Donna May'LITTLE DEVIL NINEBARK VD SB Taxus x media 'Taunton'TAUNTON YEW Spiraea betulifolia 'Tor'TOR BIRCHLEAF SPIREA Acer tataricum 'Hot Wings' GT Gleditisia triacanthos var. inermis 'Skyline'B&B UL PRINCETON SENTRY GINKGOGinkgo biloba 'Princeton Sentry' HOT WINGS TATARIAN MAPLE MS 18" Ht. 24" Ht. Hemerocallis 'Royal Occasion'ROYAL OCCASION DAYLILY 18" Ht. B&B B&B B&B DECIDUOUS ORNAMENTAL TREES SHALL BE A MINIMUM OF 6' IN HEIGHT. EVERGREEN OVERSTORY TREES SHALL BE A MINIMUM OF 6' IN HEIGHT. DECIDUOUS OVERSTORY TREES SHALL BE A MINIMUM OF 8' IN HEIGHT. MINIMUM HEIGHT REQUIREMENTS : 276 LF/40 LF = 6.9 STREET TREES REQUIRED (7 STREET TREES PROVIDED) 1 OVERSTORY TREE PER 40 LF OF FRONTAGE SE BISHOP DR. : 276 LF/40 LF = 6.9 STREET TREES REQUIRED (8 STREET TREES PROVIDED) 1 OVERSTORY TREE PER 40 LF OF FRONTAGE SE UNIVERSITY AVE. : STREET TREE REQUIREMENT: THERE ARE NO BUFFER REQUIREMENTS. BUFFER REQUIREMENT: (6 TREES PROVIDED) PARKING LOT ISLANDS SHALL HAVE A MINIMUM OF 1 OVERSTORY TREE. OFF-STREET PARKING AREAS: FOUNDATION PLANTINGS ARE REQUIRED AT THE BASE OF ALL BUILDINGS FOUNDATION PLANTINGS: 2 SHRUBS x 11.256 PU'S = 22.51 REQUIRED (115 SHRUBS PROVIDED) 0.5 UNDERSTORY TREE x 11.256 PU'S = 5.63 REQUIRED (6 UNDERSTORY TREES PROVIDED) 1 OVERSTORY TREE x 11.256 PU'S = 11.25 REQUIRED (12 OVERSTORY TREES PROVIDED) 11,256/1,000 = 11.256 PLANT UNITS (PU'S) 18 TREES REQUIRED X 25% = 4.5 EVERGREEN TREES REQUIRED (5 PROVIDED) MINIMUM OF 25% OF TOTAL REQUIRED TREES SHALL BE EVERGREEN. 1.0 OVERSTORY TREES, 0.5 UNDERSTORY TREES, AND 2.0 SHRUBS PER 1,000 SF OF REQUIRED OPEN SPACE. 75,039 SF (TOTAL LOT) x 15% = 11,255.85 SF REQUIRED (29,257 SF PROVIDED) 15% OPEN SPACE REQUIRED (LANDSCAPE CALCULATIONS BASED UPON CITY OF WAUKEE ZONING CODE REQUIREMENTS AND THE KETTLESTONE DESIGN GUIDELINES PUD) 18" Ht.Salvia nemorosa 'Caradonna'CARADONNA SALVIA Ulmus x 'Patriot' CO PRAIRIE PRIDE HACKBERRY B&BCeltis occidentalis 'Prairie Pride' PINK SPIRES CRABAPPLE 8' HT.B&B BLUES FESTIVAL ST. JOHN'S WORT SKYLINE HONEYLOCUST 1 1/2" 1 1/2" 1 1/2" 1 1/2" 8' HT. Viburnum dentatum 'Rastzam'RASPBERRY TART VIBURNUM CONT. (4' O.C.) CONT. (3' O.C.) CONT. (3' O.C.) HK PO Hypericum kalmianum 'Blues Festival' 24" Ht. 18" Ht. CONT. (3' O.C.) CA CONT. (3' O.C.)& GRASSESPERENNIALS HE Calamagrostis x acutiflora 'Karl Foerster'KARL FOERSTER FEATHER REED GRASS CONT. (2' O.C.) FG CONT. (3' O.C.)Fothergilla gardenii DWARF FOTHERGILLA TT 8' HT.JV Juniperus virginiana 'Skyrocket'SKYROCKET JUNIPER SN CONT. (2' O.C.) PATRIOT ELM 1 1/2" Malus 'Pink Spires'12' HT. MC Malus 'Coralburst'CORALBURST CRABAPPLE B&BPANORWAY SPRUCEPicea abies 8' HT. B&B8' HT.JS Juniperus scopulorum 'Medora'MEDORA JUNIPER TC B&BTilia cordata 1 1/2" LITTLELEAF LINDEN 1062 14-HK 14-PO14-PO 14-PO14-PO14-HK 1-AT 1-AT 1-AT 1-MS 1-MS 1-MS 1-MS 1-AT 1-GB 5-HK 5-HK11-HK 1-GB 1-PA 1-UL 1-UL 1-UL 1-UL 5-HK 5-HK 1-UL 1-UL 1-UL 2-CO 2-GT 2-MC 2-MC 1-AG 1-AG 3-SB 3-TT 12-CA 14-HE 6-CA 3-VD 9-SB 6-CA 6-SB 3-VD 2-JV 10-CA 5-FG 7-TT 9-SN 3-TT 9-HE 6-CA 3-SB 2-JV 6-VD 5-FG 3-SN E FEF E F E F E F E H 7-TC J J 19-JS E F BISHOP DRIVE). J. ALL AREAS IN THE RIGHT-OF-WAY WILL BE REQUIRED TO BE SODDED. (ALONG BOTH SE UNIVERSITY AVE. AND SE DEPARTMENT. I. PLANTING SUBSTITUTIONS SHALL BE APPROVED IN WRITING BY THE WAUKEE DEVELOPMENT SERVICES EQUAL. APPLY AT 30 LBS/ACRE. PROVIDE REGREEN, Tricitum aestivum, SHORT-LIVED STERILE PERENNIAL WHEAT/WHEAT GRASS HYBRID OR APPROVED SPECIFICATIONS 9010 SEEDING. LANE, WINONA, MN 55987, OR APPROVED EQUAL SEEDING RATE: 11.48 LBS/ACRE. INSTALL AS PER SUDAS PROVIDE DETENTION BASIN SEED MIX AS PROVIDED BY PRAIRIE MOON NURSERY. WWW.PRAIRIEMOON.COM, 32115 PRAIRIE H. INFORMATION. G. SOD ALL DISTURBED AREAS UNLESS NOTED OTHERWISE. REFER TO EROSION CONTROL PLAN FOR ADDITIONAL BEDS UNLESS OTHERWISE DIRECTED BY OWNER. CONTRACTOR TO INSTALL BLACK PLASTIC EDGING AROUND ALL INDIVIDUAL TREE PLANTINGS AND AT PERIMETER OF ALL PLANTING F. ALL AREAS INDICATED ON PLAN. E. PROVIDE 3-INCH DEPTH SHREDDED HARDWOOD MULCH AROUND ALL PLANTINGS TO A MIN. 3-FOOT PERIMETER, AND IN D. CONTRACTOR SHALL GUARANTEE ALL PLANT MATERIAL FOR A PERIOD OF ONE YEAR FROM DATE OF INSTALLATION. NURSERY STOCK" (ANSI Z60.1-LATEST EDITION). C. ALL PLANT MATERIAL SHALL AT LEAST MEET MINIMUM REQUIREMENTS SHOWN IN THE "AMERICAN STANDARDS FOR CONTRACTOR'S EXPENSE. COORDINATE AND COOPERATE WITH UTILITY COMPANIES DURING CONSTRUCTION. CONSTRUCTION. ANY DAMAGE DUE TO THE CONTRACTOR'S CARELESSNESS SHALL BE CORRECTED AT THE EXISTENCE, EXACT LOCATION AND DEPTH OF ALL UTILITIES. AVOID DAMAGE TO UTILITIES AND SERVICES DURING B. NOTIFY UTILITY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR DETERMINING LOCATION INDICATED. SERVICE OR ABANDONED. THE SURVEY FURTHER DOES NOT WARRANT THAT THE UTILITIES SHOWN ARE IN THE EXACT SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR RECORDS OBTAINED. THE A. UTILITY WARNING: KEY NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. NewTechWood Ultrashield Composite Siding NewTechWood Ultrashield Belgian Board Siding 5/8" Granitex by STO Firestone Delta Panel System (CFP-12, CFP12F) FACE BRICK - Glen-Gery Roman Maximus Pre-fin Sht. Mtl. Coping/Fascia Pre-fin Sht. Mtl. Soffit Standing Seam Mtl. Roof Equipment Screen Mapes Pre-fin. Mtl. Canopy Alum. Window/Storefront Skylight Reveal Joint. Signage (N.I.C.) Calwall Translucent Panel WINDOW NOTES: * WINDOW DIMENSIONS & DETAILS ARE ON A2.4 * FIELD VERIFY ALL DIMENSIONS BEFORE ORDERING * ALL WINDOWS IN BLOCK SHALL FIT TO BLOCK INCREMENTS * NOTE ALL WINDOWS TO BE TEMPERED AS PER THE FOLLOWING GLAZING W/ IN 24" OF DOOR OPENINGS GLAZING W/ IN 18" OF GROUND OR FFL * GLASS IS TO BE 1" THERMALLY BROKEN LOW E CLEAR GLASS SIGNAGE NOTE: * ALL EXTERIOR SIGNAGE TO BE ON DEDICATED CIRCUIT, COORDINATE W/ SIGNAGE PROVIDER * SIGNAGE NOT IN CONTRACT PROJECT ARCHITECT: JET THE INFORMATION CONTAINED HEREIN IS OF A PROPRIETARY NATURE AND IS SUBMITTED IN CONFIDENCE FOR USE BY THE CLIENTS OF MODERN DESIGN ARCHITECTS, INC. ONLY. THE USE OF THESE DOCUMENTS FOR ANY OTHER PROJECTS, PURPOSE, LOCATION, PUBLICATION, REPRODUCTION OR DISTRIBUTION IN WHOLE OR PART, BY ANY INDIVIDUAL OR ORGANIZATION WITHOUT WRITTEN PERMISSION FROM MODERN DESIGN ARCHITECTS, INC. IS PROHIBITED. THE INFORMATION HEREIN REMAINS THE PROPERTY OF MODERN DESIGN ARCHITECTS, INC. AND ITS USE OR DISCLOSURE TO OTHERS IS PROHIBITED FOR ANY USE NOT AUTHORIZED BY MODERN DESIGN ARCHITECTS, INC. DRAWN BY: JET JOB NO: D348-20 DATE: SHEET NO. SHEET TTLE. DRAWING ISSUE INFORMATION ISSUE: PERMIT SET DATEMARK DESCRIPTION CHECKED BY: JET - - - PRINCIPAL IN CHARGE: RJS 201 MAIN STREET JANESVILLE, IA 50647 319-987-2101 ARCHITECTS OPTOMETRIC ELITE EYECARE / ELITE VISION THERAPY WAUKEE, IA File name: D348-20- A5.0 - EEC - Exterior Elevations.vwxA5.0 ELEVATIONS 7/20/20 F.F.L. 100'-0" T.O.M. 109'-0" T.O. PARAPET 119'-0" T.O. PARAPET 124'-0" T.O. CANOPY 111'-8" T.O. PARAPET 118'-0" F.F.L. 100'-0" T.O. PARAPET 116'-0" T.O. CANOPY 109'-8" T.O.F. 97'-0" T.O.F. 97'-0" SIGNAGE SIGNAGE F.F.L. 100'-0" T.O.F. 97'-0" F.F.L. 100'-0" T.O.F. 97'-0" F.F.L. 100'-0" T.O.F. 97'-0" T.O. CANOPY 109'-8" T.O. PARAPET 122'-0" T.O. PARAPET 124'-0" T.O. PARAPET 117'-6" T.O. PARAPET 116'-0"XA4.0XA4.01 2 2 2 1 1 1 11 3 3 3 3 3 3 33XA4.03 XA4.0XA4.033 XA4.0XA4.0XA4.06 7 8 9 1 1 1 2 3 3 3 3 5 5 5 5 5 5 5 5 3 4 4 4 4 4 4 5 5 5 6 6 6 6 6 6 6 6 6 66 6 6 6 7 7 7 7 7 7 8 8 7 8 8 8 8 8 9 9 9 9 10 10 10 10 10 10 10 10 10 10 1111 11 11 11 11 11 11 11 11 1 10 10 10 10 10 6 1111 11 11 11 11 11 11 11 11 11 11 11 11 11 12 12 12 12 14 14 14 15 T.O. PARAPET 112'-0" T.O. PARAPET 122'-0" T.O. PARAPET 124'-0" F.F.L. 100'-0" T.O.F. 97'-0" T.O.PARAPET 116'-0" T.O.PARAPET 119'-0" T.O.PARAPET 121'-1 3/8" T.O. CANOPY 111'-8" T.O. CANOPY 109'-8" T.O.F. 109'-8" T.O. CANOPY 113'-8" T.O. PARAPET 116'-0" T.O. PARAPET 118'-0" T.O. PARAPET 116'-0" T.O. PARAPET 111'-0" T.O. PARAPET 119'-4" T.O. PARAPET 109'-8" F.F.L. 100'-0" T.O.F. 97'-0" T.O. CANOPY 109'-0" T.O. CANOPY 113'-8" T.O. PARAPET 124'-0" T.O. PARAPET 115'-10" WEST ELEVATION Scale: 3/16" = 1'-0"1 NORTH ELEVATION Scale: 3/16" = 1'-0"2 EAST ELEVATION Scale: 3/16" = 1'-0"3 SOUTH ELEVATION Scale: 3/16" = 1'-0"4 PRELI MI N A R Y NOT FOR CONS T R U C TI O N SLOPE 8 YARD DUMPSTER 8 YARD DUMPSTER SLOPE CONCRETE1/8":12"4 A5.1 4 A5.1 2 A5.1 3 A5.1 5A5.1ROMAN MAXIMUS BRICK 2" x 4" x 24" PREFIN MTL. CAP FLASHINGHORIZONTAL WOOD PANEL GRADE 8" TRENCH FOOTING ROMAN MAXIMUS BRICK 2" x 4" x 24" PREFIN MTL. CAP FLASHINGHORIZONTAL WOOD PANEL GRADE 8" TRENCH FOOTING ROMAN MAXIMUS BRICK 2" x 4" x 24" PREFIN MTL. CAP FLASHINGHORIZONTAL WOOD PANEL GRADE 8" TRENCH FOOTING 2" x 6" SQUARE TUBE STEEL 8" THICK OVERPOUR 2 x 8 TREATED LUMBER TOP PLATE PREFIN. MTL. CAP FLASHING GRADE 8" TRENCH FOOTING6" SLOPED CONCRETE SLAB ON GRADE8" TRENCH FOOTING 4" x 8" x 16" CMU BLOCK 4" x 8" x 16" CMU BLOCK ROMAN MAXIMUS BRICK 2" x 4" x 24" 8" THICK OVERPOUR PAVEMENT 1/2" EXPANSION JOINT HORIZONTAL WOOD PANEL 4" x 4" MTL. POST 2" x 6" SQUARE TUBE GATE FRAME 6" SLOPED CONCRETE SLAB ON GRADE 8" TRENCH FOOTING 4" x 8" x 16" CMU BLOCK 4" x 8" x 16" CMU BLOCK ROMAN MAXIMUS BRICK 2" x 4" x 24" 8" THICK OVERPOUR HORIZONTAL WOOD PANEL 4" x 4" MTL. POST 2" x 6" SQUARE TUBE GATE FRAME 4" x 8" x 16" CMU BLOCK ROMAN MAXIMUS BRICK 2" x 4" x 24" HORIZONTAL WOOD PANEL DUMPSTER ENCLOSURE PLAN Scale: 3/8" = 1'-0"1FRONT ELEVATION Scale: 3/8" = 1'-0"2 BACK ELEVATION Scale: 3/8" = 1'-0"3SIDE ELEVATION Scale: 3/8" = 1'-0"4SECTION Scale: 3/8" = 1'-0"5 PROJECT ARCHITECT: JET THE INFORMATION CONTAINED HEREIN IS OF A PROPRIETARY NATURE AND IS SUBMITTED IN CONFIDENCE FOR USE BY THE CLIENTS OF MODERN DESIGN ARCHITECTS, INC. ONLY. THE USE OF THESE DOCUMENTS FOR ANY OTHER PROJECTS, PURPOSE, LOCATION, PUBLICATION, REPRODUCTION OR DISTRIBUTION IN WHOLE OR PART, BY ANY INDIVIDUAL OR ORGANIZATION WITHOUT WRITTEN PERMISSION FROM MODERN DESIGN ARCHITECTS, INC. IS PROHIBITED. THE INFORMATION HEREIN REMAINS THE PROPERTY OF MODERN DESIGN ARCHITECTS, INC. AND ITS USE OR DISCLOSURE TO OTHERS IS PROHIBITED FOR ANY USE NOT AUTHORIZED BY MODERN DESIGN ARCHITECTS, INC. DRAWN BY: JET JOB NO: -- DATE: -- -- SHEET NO. SHEET TTLE. DRAWING ISSUE INFORMATION ISSUE: DESIGN DEVELOPMENT DATEMARK DESCRIPTION CHECKED BY: JET PRINCIPAL IN CHARGE: RJS 201 MAIN STREET JANESVILLE, IA 50647 319-987-2101 ARCHITECTS OPTOMETRIC File name: D348-20- A5.0 - EEC - Exterior Elevations.vwxA5.1 ELEVATIONS 7/20/20 PROJECT ARCHITECT: JET THE INFORMATION CONTAINED HEREIN IS OF A PROPRIETARY NATURE AND IS SUBMITTED IN CONFIDENCE FOR USE BY THE CLIENTS OF MODERN DESIGN ARCHITECTS, INC. ONLY. THE USE OF THESE DOCUMENTS FOR ANY OTHER PROJECTS, PURPOSE, LOCATION, PUBLICATION, REPRODUCTION OR DISTRIBUTION IN WHOLE OR PART, BY ANY INDIVIDUAL OR ORGANIZATION WITHOUT WRITTEN PERMISSION FROM MODERN DESIGN ARCHITECTS, INC. IS PROHIBITED. THE INFORMATION HEREIN REMAINS THE PROPERTY OF MODERN DESIGN ARCHITECTS, INC. AND ITS USE OR DISCLOSURE TO OTHERS IS PROHIBITED FOR ANY USE NOT AUTHORIZED BY MODERN DESIGN ARCHITECTS, INC. DRAWN BY: JET JOB NO: D348-20 DATE: SHEET NO. SHEET TTLE. DRAWING ISSUE INFORMATION ISSUE: PERMIT SET DATEMARK DESCRIPTION CHECKED BY: JET - - - PRINCIPAL IN CHARGE: RJS 201 MAIN STREET JANESVILLE, IA 50647 319-987-2101 ARCHITECTS OPTOMETRIC ELITE EYECARE / ELITE VISION THERAPY WAUKEE, IA File name: D348-20- A5.0 - EEC - Exterior Elevations.vwxA5.2 COLORED ELEVATIONS 7/20/20 NORTH ELEVATION1 WEST ELEVATION2 EAST ELEVATION4SOUTH ELEVATION3 ENCLOSURE ELEVATIONS5 SIDEREAR FRONT SIDE PROJECT ARCHITECT: JET THE INFORMATION CONTAINED HEREIN IS OF A PROPRIETARY NATURE AND IS SUBMITTED IN CONFIDENCE FOR USE BY THE CLIENTS OF MODERN DESIGN ARCHITECTS, INC. ONLY. THE USE OF THESE DOCUMENTS FOR ANY OTHER PROJECTS, PURPOSE, LOCATION, PUBLICATION, REPRODUCTION OR DISTRIBUTION IN WHOLE OR PART, BY ANY INDIVIDUAL OR ORGANIZATION WITHOUT WRITTEN PERMISSION FROM MODERN DESIGN ARCHITECTS, INC. IS PROHIBITED. THE INFORMATION HEREIN REMAINS THE PROPERTY OF MODERN DESIGN ARCHITECTS, INC. AND ITS USE OR DISCLOSURE TO OTHERS IS PROHIBITED FOR ANY USE NOT AUTHORIZED BY MODERN DESIGN ARCHITECTS, INC. DRAWN BY: JET JOB NO: D348-20 DATE: SHEET NO. SHEET TTLE. DRAWING ISSUE INFORMATION ISSUE: PERMIT SET DATEMARK DESCRIPTION CHECKED BY: JET - - - PRINCIPAL IN CHARGE: RJS 201 MAIN STREET JANESVILLE, IA 50647 319-987-2101 ARCHITECTS OPTOMETRIC ELITE EYECARE / ELITE VISION THERAPY WAUKEE, IA File name: D348-20- A5.0 - EEC - Exterior Elevations.vwxA5.3 ELEVATION MATERIALS 7/20/20 GLEN-GERY BRICK1COLOR: WELLINGTON VERTICAL "WOOD"2 SIDING BRANDYWINE HORIZONTAL "WOOD"2 SIDINGSTO - GRANITEX2 FIRESTONE COLORS2 SLATE GRAY BLACK