Loading...
HomeMy WebLinkAbout2019-12-16-J07 Centennial Crossing Plat 1_Final Plat AGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: December 16, 2019 AGENDA ITEM: Consideration of approval of a resolution approving final plat for Centennial Crossing Plat 1 FORMAT: Resolution SYNOPSIS INCLUDING PRO & CON: The applicant is requesting approval of a final plat for an approximately 7.93-acre subdivision generally located south of SE University Avenue and west of SE L.A. Grant Parkway. The plat includes 31 lots for townhomes and one (1) lot for the construction of a clubhouse/pool. All lots meet the minimum requirements of the R-4 District. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning Commission reviewed the request at their meeting on November 26, 2019, and recommended approval: Approval of a Final Plat for Centennial Crossing Plat 1 Senior Planner, Andy Kass, introduced the request for approval of a Preliminary Plat and Final Plat for a townhome development as submitted by the applicant, Hubbell Realty. The subject property is located south of SE University Avenue and west of SE L.A. Grant Parkway, and contains approximately 18.5 acres. Mr. Kass advised that the area was recently rezoned to R-4/ PD to allow for the townhome project. To date, staff has received one letter correspondence stating concerns against the proposed project. Mr. Kass advised that the preliminary plat shows a total 130 lots split between two phases as well as a Clubhouse and clubhouse amenities. Phase one will be constructed east of the existing drainage way and include 32 lots, and phase two will be constructed to the west of the existing drainage way and contain approximately 98 lots. All proposed lots meet the requirements of the R-4/PD zoning district. All streets interior to the development are private streets and will be owned and maintained by the owner or owners association. Two connections to SE University Avenue, and one connection to SE L.A. Grant Parkway are shown. The applicant also intends to provide a connection to SE Booth Avenue by reconstructing the existing access to the south. Sidewalks are planned along one side of each street within the development and visitor parking is available throughout the development. Mr. Kass explained that all utilities are available to the site, including a public sanitary sewer main that will need to be relocated as part of the development. Stormwater detention will be J7 provided in the existing drainage way that runs from the southeast of the property to the north before it outlets into a box culvert that flows into centennial park. Storm water detention will be maintained by the owner or owners association. in lieu of the required 1.75 acres of parkland, the applicant has proposed to construct a trail along the greenway that separates plat 1 and plat 2. The trail would connect to SE University Avenue, and to SE L.A. Grant Parkway. The applicant has also proposed the construction of a bridge across the drainage way, and there has been discussion of a culvert for access to centennial park as part of improvements to SE University Avenue in the future. At this time staff would recommend approval subject to any remaining staff comments. Commissioner Koshy questioned if Staff would highlight changes that have been made since the rezoning to address current resident concerns. Mr. Kass advised that there were several changes. In regards to draining, both the Stormwater maintenance of the site and the eventual SE University City Project would improve the run off occurring in the area. Landscaping buffers are required to the north and east, and while there is no buffer required to the west, staff has worked with the applicant to allow plantings from the north buffer to be placed as screening to the west of the development. Commissioner Streit questioned if the concept viewed at the time of rezoning was the same as what was proposed now. Mr. Kass advised that there were some changes, one building was required to lose a unit to comply with fire safety regulations. Several access points have been realigned taking into account the future updates to SE University. Finally, the arrangement of the one story homes versus two story homes has been altered. Commissioner Hoifeldt questioned for an update on the lay out of the development in regards to one story vs two story units. A representative for the applicant, Matt Weller, advised that the two story units had been moved more central to the development allowing the one story units to border the current homes to the west of the property. Commissioner Tietz questioned what the time line of the university project would be. Director of Development, Brad Deets, advised that this portion would be slated for work in 2024, funding permitting. Commissioner Hoifeldt asked for more information regarding the drainage plan and if the applicants felt what was proposed would handle the issues until such a time as SE University was updated by the City. A representative for the applicant, Caleb Smith of McClure Engineering, advised that the Stormwater management had been created by looking at the project as a worst case scenario. The applicant is confidant that the calculations and proposed project are able to accommodate the Stormwater issues of the site. Commissioner Hoifeldt questioned staff if the intent was to eventually have the park maintain Stormwater. Mr. Kass advised that the Stormwater management is still a concern that the City will need to make a decision on when dealing with the SE University Avenue Project, and that a sure answer was unavailable at this time. Commissioner Hoifeldt questioned if the applicant felt there was adequate visitor parking, especially in plat 2 and if they had concerns regarding street parking. Mr. Smith advised that the parking exceeded what was required, and that the applicants believed adequate visitor parking had been provided. As these are rental units, a professional management company can enforce the no parking regulations for street parking. Commissioner Hoifeldt moved to approve the Final Plat for Centennial Crossing Plat 1 Subject to any remaining staff comments. Commissioner Tietz seconded the motion. Ayes: Ward, Tietz, Streit, Hoifeldt, Koshy, and Freund. Nays: None. Motion Carries. STAFF REVIEW AND COMMENT: Staff’s position is that the proposed final plat meets the intent and the requirements of the R-4/PD-1 Zoning District and that the applicant has successfully addressed all of the requirements within the Waukee Subdivision Ordinance with the submittal of this final plat. RECOMMENDATION: Staff recommends approval of the Final Plat for Centennial Crossing Plat 1 ATTACHMENTS: I. Resolution II. Staff Report III. Final Plat PREPARED BY: Andy Kass, Senior Planner REVIEWED BY: PUBLIC NOTICE INFORMATION – NAME OF PUBLICATION: DATE OF PUBLICATION: THE CITY OF WAUKEE, IOWA RESOLUTION 19- APPROVING THE FINAL PLAT FOR CENTENNIAL CROSSING PLAT 1 IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, Broderick Charitable Foundation Trust U/A/D 10/8/2019, has requested final plat approval of Centennial Crossing Plat 1 (the “Plat”); AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Plat on November 26, 2019, subject to remaining staff comments and review of the legal documents; AND, WHEREAS, the Final Plat for Centennial Crossing Plat 1 and the documents relating thereto will comply with Section §303 - Land Subdivision Ordinance of the Waukee Municipal Code. NOW, THEREFORE, BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 16th day of December, 2019, that the Final Plat for Centennial Crossing Plat 1 be and the same is hereby accepted and approved by the City Council of the City of Waukee. BE IT FURTHER RESOLVED that the City of Waukee does hereby accept the following easements and documents to be filed with the Plat: 1. Warranty Deed (Lots B and C) 2. Public Water Main Easement; 3. Public Utility Easement; 4. Public Use & Facility Easement; 5. Public Surface Water Flowage Easement; 6. Public Sanitary Sewer Easement; 7. Public Ingress/Egress Easement; 8. Public Gas Main Easement; 9. Public Bike Trail Easement; 10. Storm Sewer Easement (private); 11. Sign Easement (private); 12. Landscape Buffer Easement (private); and 13. Infrastructure Easement (private). ____________________________ William F. Peard, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Anna Bergman R. Charles Bottenberg Courtney Clarke Shelly Hughes Larry R. Lyon PLANNING AND ZONING COMMISSION STAFF REPORT PROJECT: Centennial Crossing Plat 1 & 2 – Preliminary Plat & Final Plats PREPARED BY: Andy Kass AICP, Senior Planner REPORT DATE: November 22, 2019 MEETING DATE: November 26, 2019 GENERAL INFORMATION Applicant: Hubbell Realty Company Owner: Philip E. Broderick Owner’s Representative: Caleb Smith, P.E., McClure Engineering Request: The applicant is requesting approval of a preliminary plat and final plat for a townhome residential subdivision. Location and Size: Property is generally located south SE University Avenue and west of SE L.A. Grant Parkway containing approximately 18.41-acres more or less. AREA MAP ABOVE: Aerial of Property identifying the proposed plat (outlined in BLUE). November 22, 2019 2 of 3 LAND USES AND ZONING Location Existing Land Use Comprehensive Plan Current Zoning Property in Question Vacant – Undeveloped Medium Density Residential & Neighborhood Commercial R-4 (Row Dwelling & Townhome District) / PD-1 (Planned Development Overlay) North Centennial Park Park COS (Conservation & Open Space) South Vacant – Undeveloped Medium Density Residential R-4 (Row Dwelling & Townhome District) / PD-1 (Planned Development Overlay) East Kum & Go Neighborhood Commercial C-1A (Neighborhood Commercial) West Glynn Village Single Family Residential R-1 (Single Family Residential District) / PD-1 (Planned Development Overlay) HISTORY The subject property is located south of SE University Avenue and west of SE L.A. Grant Parkway. The property was the subject of a rezoning in the summer of 2019. The property was rezoned from A-1 to R-4/PD-1. The planned development was added to the rezoning to allow for reduced setbacks in areas along the perimeter of the property and along the internal private streets. In addition, the planned development allows for up to 7 units to be attached. PROJECT DESCRIPTION LOTS The preliminary plat and final plats identify a total of 32 lots in Plat 1 and a total of 98 lots in Plat 2. Plat 1 is located on the east side of the property and Plat 2 is located on the west side of the property. Table 1 below summarizes the minimum requirements for the lots. All proposed lots meet the minimum requirements. Details on the proposed buildings and units are available in the individual staff reports regarding the site plans for Centennial Crossing Plat 1 and 2. Lot 32 in Plat 1 will have a clubhouse and pool constructed upon it for the use of the residents. A 25-foot landscape buffer is required along the north and east sides of the development. Table 1: Bulk regulations Category R-4/PD-1 (minimum) Lot Area 3500 square feet per unit Lot Width 20 feet Front Yard Setback 20 feet w/out a sidewalk, 25 feet w/ a sidewalk, 25 feet along east, west, north perimeter, and 15 feet on south perimeter Rear Yard Setback 30 feet Side Yard Setback 15 feet November 22, 2019 3 of 3 STREETS AND TRAIL As part of the improvements for the development there are no public streets that will be constructed. All internal streets will be owned and maintained by the owner or the owners association. Two connections to SE University Avenue are shown and one connection to SE L.A. Grant Parkway is shown. In addition, the applicant intends to provide a connection to SE Booth Avenue to the south by reconstructing the existing access to the south. The internal streets will be 24-feet wide with a concrete pavement depth of 7-inches. Five-foot sidewalks are planned along one side of each street within the development except for one. Visitor parking will be provided throughout the development. UTILITIES A portion of an existing public sanitary sewer main will need to be relocated as part of the development. The existing public sewer runs diagonally along the drainageway through the property. Sanitary sewers stubbed from the public sewer will be privately owned and maintained. In addition, the water main and storm sewer throughout the development will all be privately owned and maintained. Stormwater detention will be provided in an existing drainageway that runs from the southeast of the property to the north and outlets into a box culvert that flows into Centennial Park. Ownership and maintenance of drainageway will be the responsibility of the owner or owners association. PARKLAND DEDICATION The two plats will have a total of 129 units. The required parkland for 129 units is 1.75 acres. In lieu of dedicating parkland, the applicant has proposed to construct a trail along the greenway that separates Plat 1 from Plat 2. The trail would connect to SE University Avenue and SE L.A. Grant Parkway. In addition, the applicant intends to construct a pedestrian bridge across the drainageway to allow access to the west side of the development. STAFF RECOMMENDATION The proposed lots meet the minimum requirements of the Zoning Ordinance. The preliminary plat and final plats are in general conformance with the Subdivision Ordinance. Staff recommends approval subject to remaining staff comments. S89°48'41"E 644.04'N00°00'00"E60.00'N31°59'23"W 264.19'N34°40'17"W 454.62'N00°05'01"E66.84'C1N00°00'27"E68.07'N89°54'59"W 206.06'S00°22'51"W 837.69' (M) S00°00'00"W 840.92' (R)S89°48'41"E 1668.62' (M)S89°42'11"E 1668.86' (R)S89°58'04"W 278.51' (M)N89°41'53"E 278.51' (R)S00°22'51"W 59.00' (M)S00°06'40"W 59.00' (R)S00°22'51"W 812.83' (M)S00°00'00"W 812.83' (R)Curve TableCurve #C1Length61.66'Radius49.00'Delta72°05'54"CHD BN36°02'30"WCHD L57.67'DRAWING NO.CREW CHIEFENGINEERSHEET NO.SURVEYORDRAWN BYREVISIONSmaking lives better./01DRAWING PATH:CENTENNIAL CROSSINGFINAL PLAT 1WAUKEE, IOWA2021802310/02/2019.....C.SMITHC.CARLETONM.LEE----FP-0103DALLAS COUNTYHUBBELL REALTY COMPANY6900 WESTOWN PARKWAYWEST DES MOINES, IOWA 50266R-4 (ROW DWELLING & TOWNHOME DWELLING DISTRICT)RECORDED IN BOOK 2019, PAGE 14760MINIMUM BUILDING SETBACKSSIDE TO SIDE SEPARATION:15 FEETSIDE TO FRONT/REAR SEPARATION:30 FEETREAR TO REAR SEPARATION:30 FEETGARAGE TO DRIVE:20 FEET OR 25 FEET WITH SIDEWALKDRIVE TO HOUSE:10 FEETA PART OF LOT GOVERNMENT LOT 1, IN SECTION 5, TOWNSHIP 78 NORTH, RANGE 26 WEST OF THE FIFTHPRINCIPAL MERIDIAN IN THE CITY OF WAUKEE, DALLAS COUNTY, IOWA MORE PARTICULARLY DESCRIBED ASFOLLOWS:BEGINNING AT THE NORTHEAST CORNER OF LOT 'A', GLYNN VILLAGE PLAT 1; THENCE NORTH 89°54'59" WESTALONG THE NORTHERLY LINE OF SAID GLYNN VILLAGE PLAT 1, A DISTANCE OF 206.06 FEET; THENCE NORTH00°00'27" EAST, 68.07 FEET; THENCE NORTHWEST ALONG A CURVE CONCAVE SOUTHWEST WHOSE RADIUS IS49.00 FEET, WHOSE ARC LENGTH IS 61.66 FEET AND WHOSE CHORD BEARS NORTH 36°02'30" WEST, 57.67FEET; THENCE NORTH 00°05'01" EAST, 66.84 FEET; THENCE NORTH 34°40'17" WEST, 454.62 FEET; THENCENORTH 31°59'23" WEST, 264.19 FEET; THENCE NORTH 00°00'00" EAST, 60.00 FEET TO THE NORTH LINE OF SAIDSECTION 5; THENCE SOUTH 89°48'41" EAST ALONG SAID NORTH LINE, 644.04 FEET TO THE NORTHEASTCORNER OF SAID SECTION 5; THENCE SOUTH 00°22'51" WEST ALONG THE EAST LINE OF SAID SECTION 5, ADISTANCE OF 837.69 FEET TO THE POINT OF BEGINNING AND CONTAINING 7.93 ACRES (345,513 SQUARE FEET)THE PROPERTY IS SUBJECT TO ANY AND ALL EASEMENTS OF RECORD.NORTH(IN FEET)100502501 inch = 50 ft.MCCLURE1360 NW 121ST STREETCLIVE, IA 50325(515) 964-1229CSMITH@MECRESULTS.COMATTN: CALEB SMITHSHEETS 1-3TRS: SECTION 5, T78N, R26WLOT: GOVERNMENT LOT 1CITY: WAUKEEPROPRIETOR: PHILIP E BRODERICK TRUSTREQUESTED BY: HUBBELL REALTYSURVEYOR: MICHAEL D. LEECOMPANY: MCCLURERETURN TO: MICHAEL D. LEE1360 NW 121ST STREET, STE ACLIVE, IOWA 50325 / 515-964-1229COUNTY: DALLASVICINITY MAP- NTSPROJECTAREASURVEY BOUNDARYPROPOSED LOTEXIST PROPERTY LINESECTION LINESETBACK LINEEASEMENT LINEFNDPCBK, PG(M), (R)R.O.W.P.U.E.P.O.B.P.O.C.FOUNDPLASTIC CAPBOOK AND PAGEMEASURED, RECORDEDRIGHT-OF-WAYPUBLIC UTILITY EASEMENTPOINT OF BEGINNINGPOINT OF COMMENCEMENTMONUMENTS FOUND:SECTION CORNER(TYPE AS NOTED)5/8" REBAR W/YPC #15268(UNLESS NOTED OTHERWISE)CUT X1/2" REBAR W/YPC #16747MONUMENTS SET:1234567891011121314151617181920212223242526272829303132STREET LOT 'C'STREET LOT 'A'STREET LOT 'B'OUTLOT 'Z'SE COR, SEC 33-79-26FND GIN SPIKENE COR, SEC 5-78-26FND CUT 'X'1360 NW 121st Street, STE AClive, Iowa 50325515-964-1229fax 515-964-2370NE COR, PARCEL 'A'FND 1/2" REBARNE COR, LOT 'A'GLYNN VILLAGE PLAT 1FND CUT 'X'P.O.B.SE COR, GOV'T LOT 1SEC 5-78-26FND CUT 'X'NE COR, LOT 136GLYNN VILLAGE PLAT 1THE FINAL PLAT FOLLOWS SEVERAL RECORDED SURVEYS AND ROAD PLANS THAT ARE NOT RECORDED. THEFOLLOWING IS A LIST OF ITEMS·SECTION PLATTED 1848·PLAT OF SURVEY RECORDED 4/1/1972 - SLIDE 'A' PAGE 99·CORNER CERTIFICATE 1974 - ENGINEER RECORDS·DALLAS COUNTY ROAD PLANS 1975·CORNER CERTIFICATE 1976 - ENGINEER RECORDS·PLAT OF SURVEY RECORDED 6/30/1995 - BOOK 789 PAGE 1164·CORNER CERTIFICATE - RECORDED 10/27/1997 BOOK 850 PAGE 621·PARK VIEW CROSSING RECORDED 6/10/1999 - BOOK 1999 PAGE 6512·CORNER CERTIFICATE RECORDED 10/20/2000 - BOOK 2000 PAGE 13054·MUNICIPAL EASEMENT RECORDED 6/11/2001 - BOOK 2001 PAGE 6386·PLAT OF SURVEY RECORDED 8/23/2005 - BOOK 2005 PAGE 13670·GLYNN VILLAGE PLAT 1 RECORDED 3/6/2006 - BOOK 2006 PAGE 3292·CITY OF WAUKEE AND DALLAS COUNTY ROAD PLANS 2007·CORNER CERTIFICATE RECORDED 4/29/2019 - BOOK 2019 PAGE 6068THE NORTHEAST CORNER OF THE SECTION 5 WAS CALLED OUT BEING 3.23 NORTH OF A FOUND CUT 'X' ONTHE SUBDIVISION OF GLYNN VILLAGE. THE METHOD USED WAS NOT CONSISTENT WITH THE PREVIOUSDOCUMENTS.THIS FINAL PLAT IS HOLDING THE FOUND CUT 'X' WHICH IS STATED IN THE PREVIOUS DOCUMENTS. THEFOUND CUT 'X' IS SHOWN MATCHING THE SUBDIVISION OF PARK VIEW CROSSING. PARK VIEW CROSSINGMATCHES THE SURROUNDING SURVEYS OF THE INTERSECTION TO THE NORTHEAST, NORTHWEST AND THEMETHOD USED IN THE MUNICIPAL EASEMENT AND ROAD PLANS OF 2007. THE MUNICIPAL EASEMENT ANDROAD PLANS OF 2007 ARE LOCATED ON THE SUBJECT PROPERTY.JANUARY 17, 2019SE UNIVERSITY AVENUESE LA GRANT PARKWAY SE BOOTH AVENUES00°22'51"W 1650.52'(M) S00°00'00"W 1653.75'(R) SEE NOTESN89°54'59"W 71.00'(M)S89°42'11"W 71.00'(R)N89°54'59"W 229.65'(M)S89°42'11"W 229.84'(R)NE COR, LOT 139GLYNN VILLAGE PLAT 1S89°48'41"E 1668.62'(M)N89°48'11"E 1668.86'(R)SEE NOTESSE UNIVERSITY AVENUEWARRIOR LANE SE LA GRANT PARKWAYSE PLEASANT VIEW DRIVESE WADDELL WAY S89°48'41"E1024.58'(M)1/2" REBAR W/YPC #16747WITNESS CORNER SET 1.00 FEETAWAY FROM CORNER ON LOTLINE OR PERPENDICULAR FROMCURVE POINT·PRIVATE UTILITIES AND LANDSCAPE BUFFER SHALL BE MAINTAINED BYTHE HOMEOWNERS ASSOCIATION·LOT 32, STREET LOT 'A' AND OUTLOT 'Z' TO BE OWNED AND MAINTAINEDBY THE HOMEOWNERS ASSOCIATION·STREET LOTS 'B' & 'C' ARE TO BE DEDICATED TO THE CITY OF WAUKEEWITH RECORDATION OF THIS PLAT·THE PROPOSED TRAIL ALONG THE WEST LINE OF PLAT 1 IS BEINGDEDICATED IN LIEU PARKLAND DEDICATION 12.00'12.00'12.00'12.00'12.00'12.00'S58°45'59"E 149.87'S34°40'17"E 357.67'S07°55'20"E 226.97'S89°48'41"E 218.71'S89°48'41"E 285.70'L1C18N34°40'17"W 191.24'C19C20 N00°11'19"E 91.29' S00°22'51"W 837.69'S89°54'59"E 206.06'S31°59'23"E 264.19'S34°40'17"E 454.62'24' R.O.W.12'12'24' R.O.W.12'12'N85°08'55"E 136.82'N85°08'55"E 132.85'N85°08'55"E 129.89'N85°08'55"E 129.89'N85°08'55"E 132.94'N64°32'19"E 128 .03 'N55°19 '43 "E 123 .00 'N55°19 '43 "E 123 .00 'N55°19 '43 "E 123 .00 'N55°19 '43 "E 123 .00 'N55°19 '43 "E 123 .00 'N55°19 '43 "E 123 .00 ' N 3 1 ° 1 4 ' 0 1 " E 1 3 2 . 9 9 ' N3 1 ° 1 4 ' 0 1 " E 1 2 5 . 4 4 ' N3 1 ° 1 4 ' 0 1 " E 1 2 5 . 4 4 ' N3 1 ° 1 4 ' 0 1 " E 1 3 2 . 9 9 ' N3 1 ° 1 4 ' 0 1 " E 1 2 3 . 0 0 ' N00°11'19"E 106.00' N00°11'19"E 106.00' N00°11'19"E 106.00' N00°11'19"E 106.00' N00°11'19"E 106.00' S00°11'19"W 119.00' S00°11'19"W 119.00' S00°11'19"W 119.00' S00°11'19"W 119.00' S00°11'19"W 119.00' S00°11'19"W 119.00' 58.18' 91.29'C14C1337.00'28.00'28.00'28.00'28.00'28.00'79.81'68.48'28.00'28.00'28.00'28.00'64.26'C 1 5 C1638.58'28.00'28.00'28.00'28.00'68.13'106.00'119.00'194.41'11.07'C17C2C3C4C5C6C723.29'49.65'28.00'28.00'28.00'28.00'6.30'C8C9C10 C11 C12 28.11'5.00'70.92'28.04'28.04'28.04'28.04'43.89'43.18'68.72'28.00'28.00'28.00'28.00'49.65'84.12'28.00'28.00'28.00'28.00'33.04'S89°37'09"E 80.78'128.34'182.04'C21S00°00'27"W 68.07' N00°05'01"E 66.84'11.07'57.14'28.00'28.00'28.00'28.00'28.00'80.21'146.30'50.00'60.00' N00°00'00"E 60.00' 777.69'50.00'156.06'N89°48'41"W 644.04'145.99'196,710 SF20 3,332 SF 21 3,332 SF 22 3,332 SF 23 3,332 SF 24 3,332 SF 259,522 SF267,240 SF317,193 SF27 2,968 SF 28 2,968 SF 29 2,968 SF 30 2,968 SF 3228,510 SF67,610 SF23, 6 0 5 S F 33, 4 6 7 S F 43, 4 6 7 S F 53, 6 0 5 S F 127,274 SF173,775 SF153,630 SF138,225 SF113,444 SF103,444 SF93,444 SF83,444 SF76,107 SF189,100 SF110,092 SFSTREET LOT 'C' 38,887 SF 143,672 SF163,672 SFSTREET LOT 'B'38,630 SFOUTLOT 'Z'68,253 SFSTREET LOT 'A'20,958 SF164.83'26.41'4.83'60.00' HALF R.O.W.50.00'HALF R.O.W.(295)(289)(283)(277)(271)(265)(259)(276)(282)(288)(294)(300)(270)(1200)(1210)(1220)(1230)(1240)(1250)(1260)(1270)(1280)(1290)(1300)(1310)(1320)(1330)(1350)(1360)(1370)(1340)(1325)Line TableLine #L1DirectionN89°37'09"WLength11.07'Curve TableCurve #C18C19C20C21Length143.85'112.23'39.87'61.66'Radius150.00'250.00'250.00'49.00'Delta54°56'52"25°43'18"9°08'19"72°05'54"CHD BN62°08'43"WN21°48'39"WN04°22'50"WS36°02'30"ECHD L138.40'111.29'39.83'57.67'DRAWING NO.CREW CHIEFENGINEERSHEET NO.SURVEYORDRAWN BYREVISIONSmaking lives better./02DRAWING PATH:CENTENNIAL CROSSINGFINAL PLAT 1WAUKEE, IOWA2021802310/02/2019.....C.SMITHC.CARLETONM.LEE----FP-0103DALLAS COUNTYNORTH(IN FEET)100502501 inch = 50 ft.1360 NW 121st Street, STE AClive, Iowa 50325515-964-1229fax 515-964-2370SURVEY BOUNDARYPROPOSED LOTEXIST PROPERTY LINESECTION LINESETBACK LINEEASEMENT LINEFNDPCBK, PG(M), (R)R.O.W.P.U.E.P.O.B.P.O.C.FOUNDPLASTIC CAPBOOK AND PAGEMEASURED, RECORDEDRIGHT-OF-WAYPUBLIC UTILITY EASEMENTPOINT OF BEGINNINGPOINT OF COMMENCEMENTMONUMENTS FOUND:SECTION CORNER(TYPE AS NOTED)5/8" REBAR W/YPC #15268(UNLESS NOTED OTHERWISE)CUT X1/2" REBAR W/YPC #16747MONUMENTS SET:1/2" REBAR W/YPC #16747WITNESS CORNER SET 1.00 FEETAWAY FROM CORNER ON LOTLINE OR PERPENDICULAR FROMCURVE POINT 50.00' PUBLIC INGRESS/EGRESS& PRIVATE INFRASTRUCTUREEASEMENT20.00' PRIVATE STORM SEWEREASEMENT AND PUBLIC SURFACEWATER FLOWAGE EASEMENT15.00' PRIVATE WATERMAIN EASEMENT(DETAIL B)30.00' PUBLIC SANITARYSEWER EASEMENT(DETAIL A)20.00' PRIVATE STORMSEWER EASEMENT(DETAIL C)20.00' FRONTSETBACK20.00' FRONTSETBACK50.00' PUBLIC INGRESS/EGRESS& PRIVATE INFRASTRUCTUREEASEMENTEXISTING 60' MUNICIPALUTILITIES EASEMENT(BK 2001, PG 6386)EXISTINGCENTURYLINK EASEMENT(BK 2014, PG 17970)EXISTING40.0' R.O.W.(BK 462, PG 31)10.00'P.U.E.10.00'P.U.E.EXISTING STORMSEWER EASEMENT(BK 2006, PG 3292)EXISTING SANITARYSEWER EASEMENT(BK 2006, PG 3292)30.00' PRIVATESTORM & SANITARYSEWER EASEMENT10.00'P.U.E.EXISTING 60' STORM SEWER SURFACEWATER FLOWAGE EASEMENT(BK 1999, PG 2121)EXISTING 33' R.O.W.15x15' PRIVATESIGN EASEMENT15'x12' PRIVATESIGN EASEMENT(DETAIL I)EXISTING 10' P.U.E.(BK 2006, PG 3292)10.00'P.U.E.15.00' REARSETBACKPUBLIC USE & FACILITIES EASEMENT (DETAIL E) 13.00' 13.00'13.00 '13.00'30.00' PUBLIC BIKE TRAIL ANDPUBLIC SURFACE WATERFLOWAGE EASEMENT25.00' PUBLIC BIKE TRAIL ANDPUBLIC SURFACE WATERFLOWAGE EASEMENT15'x15' PRIVATE SIGN EASEMENT 10.00' PUE AND 10.00' PRIVATE STORMSEWER & PUBLIC SURFACE WATERFLOWAGE EASEMENT (SOUTH 10' OF LOT 26 & 27)13.00' PUBLIC INGRESS/EGRESS & PRIVATEINFRASTRUCTURE EASEMENTPRIVATE STORMSEWER EASEMENT(DETAIL F)DETAIL D15 . 0 0 'PUBLIC BIKE TRAIL& PUBLIC SURFACEWATER FLOWAGE EASEMENT(DETAIL G)25.00' SETBACKPRIVATE LANDSCAPEBUFFER25.00' SETBACKPRIVATE LANDSCAPEBUFFERPRIVATE STORM SEWER &PUBLIC SURFACE WATERFLOWAGE EASEMENT10'5.00' GASEASEMENT20.00' PUBLICTRAIL EASEMENT(DETAIL J)25.00' SETBACK PRIVATE LANDSCAPE BUFFERC22C23S89°37'09"E11.07'N00°22'51"E 84.48'N56°24'12"E 204.93'S56°24'12"W 206.93'S00°22'51"W 92.42'C2615.00' PRIVATE WATERMAIN EASEMENTS62°39'44"E93.79'S31°13'21"E 289.45'S47°32'50"E38.48'N62°39'44"W 117.49'N31°13'21"W 295.56'N40°07'06"W 336.39'S00°22'51"W33.66'S00°22'51"W32.71'S31°59'23"E38.86'30.00' PUBLIC SANITARYSEWER EASEMENTS40°07'06"E 475.77'N31°59'23"W 176.98'Curve TableCurve #C23C24C25C26C27C28C29C30C31Length3.93'22.75'29.23'6.23'34.76'38.12'57.55'20.19'70.05'Radius162.00'49.00'49.00'49.00'250.00'20.00'90.00'49.00'110.00'Delta1°23'19"26°36'11"34°10'51"7°17'24"7°58'02"109°12'13"36°38'23"23°36'22"36°29'05"CHD BS88°55'30"EN47°28'29"WN17°04'59"WN68°26'44"WN23°22'35"WN35°35'13"ES72°03'39"WN30°45'53"WN72°08'18"ECHD L3.93'22.55'28.80'6.23'34.74'32.61'56.58'20.05'68.87'10.00'13.00'30.00'35.00'PUBLIC USE ANDFACILITY EASEMENTS89°48'41"E40.01'S00°15'02"W 67.56'30.00' PUBLIC BIKE TRAIL ANDPUBLIC SURFACE WATERFLOWAGE EASEMENTS85°08'55"W30.04'C24C2520.00' PRIVATE STORMSEWER EASEMENTS15°01'35"W59.21'S74°58'25"E 20.00'N15°01'35"E 48.79'C27C28 S89°48'41"E16.19'S20°07'32"W 62.14'N89°48'41"W48.07'PRIVATE STORMSEWER EASEMENTN38°41'59"W 29.81'25.23'15.00'PUBLIC BIKE TRAIL & PUBLICSURFACE WATER FLOWAGEEASEMENTN89°48'41"W 97.02'S78°43'00"W 52.66'N81°26'16"E38.90'N67°57'22"E 52 .04 'S67°57'22"W 46 .91 'S00°22'51"W10.00'N34°40'17"W15.37'S89°48'41"E 114.25'PRIVATE STORM SEWER & PUBLIC SURFACE WATER FLOWAGE EASEMENT15' X12' PRIVATESIGN EASEMENTS89°37'09"E 45.06'N89°37'09"W 45.06'C29C31N55°21'53"E 72.24'S55°21'53"W 73.87'C30S00°22'51"W20.00'20.00' PUBLIC TRAILEASEMENTS00°22'51"W18.70'DRAWING NO.CREW CHIEFENGINEERSHEET NO.SURVEYORDRAWN BYREVISIONSmaking lives better./03DRAWING PATH:CENTENNIAL CROSSINGFINAL PLAT 1WAUKEE, IOWA2021802310/02/2019.....C.SMITHC.CARLETONM.LEE----FP-0103DALLAS COUNTYNORTH(IN FEET)100502501 inch = 50 ft.1360 NW 121st Street, STE AClive, Iowa 50325515-964-1229fax 515-964-23701234567891011121314151617181920212223242526272829303132STREET LOT 'C'STREET LOT 'A'STREET LOT 'B'OUTLOT 'Z'EXHIBIT A: PUBLIC SANITARY SEWER EASEMENT1"=100'EXHIBIT B: PRIVATE WATER MAIN EASEMENT1"= 50'1234567891011121314151617181920212223242526272829303132STREET LOT 'C'STREET LOT 'A'STREET LOT 'B'OUTLOT 'Z'123456OUTLOT 'Z'EXHIBIT E: PUBLIC USE AND FACILITY EASEMENT1"=50'252423EXHIBIT C: PRIVATE STORM SEWER EASEMENT1"=50'EXHIBIT D: PUBLIC BIKE TRAIL & PUBLICSURFACE WATER FLOWAGE EASEMENT1"=50'OUTLOT 'Z'OUTLOT 'Z'1618EXHIBIT F: PRIVATE STORM SEWER EASEMENT1"=50'313029EXHIBIT G: PUBLIC BIKE TRAIL & PUBLICSURFACE WATER FLOWAGE EASEMENT1"=50'546EXHIBIT H: PRIVATE STORM SEWER & PUBLICSURFACE WATER FLOWAGE EASEMENT1"=30'32313029282726EXHIBIT I: PRIVATE SIGN EASEMENT1"=50'252413.00'12.00'10.00'15.00'EXHIBIT J: PUBLIC TRAIL EASEMENT1"=50'OUTLOT 'Z'LOT 1