Loading...
HomeMy WebLinkAbout2018-04-16-J11 Bluestem Plat 2_Revised Prelim Plat AGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: April 16, 2018 AGENDA ITEM: Consideration of approval of a resolution approving a revised preliminary plat for Bluestem Plat 2. FORMAT: Resolution SYNOPSIS INCLUDING PRO & CON: Jerry’s Homes, Inc., request approval of a revised preliminary plat for 23.18 acres of property located south of SE Tallgrass Lane and east of SE L.A. Grant Parkway. The plat consists of 63 lots intended for single family residential development. The plat indicates that lots will range in size from 8,040 square feet to 27,002 square feet, with lot widths ranging from 65 feet to 135 feet. As part of the public improvements extensions of SE Esker Ridge Drive and SE Bluestem Drive, along with two other street will occur in addition to the extensions of public utilities. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning Commission reviewed this request on April 10, 2018, and recommended approval subject to remaining staff comments. Approval of a Preliminary Plat for Bluestem Plat 2 City Planner, Melissa DeBoer, introduced the request for a preliminary plat located east of SE LA Grant Parkway and north of Ashworth Road, containing about 23 acres. The property is zoned R-2, One and Two Family Residential. Ms. DeBoer explained that this property had been approved for a preliminary plat in 2014, but since then the ownership has changed and a new preliminary plat has been proposed. The original layout included 54 single family lots and this revised layout identifies 63 single family lots. In addition to the change in number of lots, one less street will be continued to the east than what was originally proposed. Ms. DeBoer discussed lot sizes and explained that all lots meet the requirements of the R-2 zoning district. In addition, all utilities will be extended to this plat. Parkland dedication has been satisfied through previously dedicated parkland within the Stone Prairie development, located on the west side of SE LA Grant Parkway. Ms. DeBoer explained that all proposed lots meet the minimum requirements of the Zoning Ordinance and the use of the property is consistent with the Neighborhood Residential classification in the Comprehensive Plan. Staff recommended approval of the preliminary plat for Bluestem Plat 2, subject to any remaining staff comments.  Commissioner Tietz questioned if the lots backing to LA Grant Parkway would have landscape buffered and if there would be a berm. Ms. DeBoer advised that there is a 25 foot landscape buffer easement on those lots, and a slight berm, around 3 feet. J11  Commissioner Broderick questioned if there were any concerns with access further east with just the two streets, SE Tallgrass Lane and SE Esker Ridge Drive. He also questioned what the distance was between the two streets. Ms. DeBoer advised there was approximately 1200 feet between the two streets and staff did not see a concern with access to eastern developments.  Commissioner Tietz questioned if the applicant owned the parcel to the east, and if the beginning cul-de-sac shown on the map would be included in the eastern development. Ms. DeBoer advised that yes, the property owner was the same on both parcels, and that the location in question would be involved with future eastern development. Commissioner Broderick made a motion to approve the Preliminary Plat for Bluestem Plat 2. Commissioner Ward seconded the motion. Ayes: Ward, Tietz, Broderick, and Martin. Nays: None. Motion Carries. STAFF REVIEW AND COMMENT: All staff comments have been addressed. Staff recommends approval. RECOMMENDATION: Approve the resolution. ATTACHMENTS: I. Proposed Resolution II. Staff Report III. Preliminary Plat PREPARED BY: Andy Kass, Senior Planner REVIEWED BY: THE CITY OF WAUKEE, IOWA RESOLUTION 18- APPROVING THE BLUESTEM PLAT 2 REVISED PRELIMINARY PLAT IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission reviewed and recommended approval of a revised Preliminary Plat for Bluestem Plat 2 on April 10, 2018, subject to remaining staff comments; AND, WHEREAS, the revised Preliminary Plat for Bluestem Plat 2 is in general conformance with section §303 - Land Subdivision Ordinance of the Waukee Municipal Code. NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this the 16th day of April, 2018, that the revised Preliminary Plat for Bluestem Plat 2 be approved. ____________________________ William F. Peard, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Anna Bergman R. Charles Bottenberg Courtney Clarke Shelly Hughes Larry R. Lyon PLANNING AND ZONING COMMISSION STAFF REPORT PROJECT: Bluestem Plat 2 – Preliminary Plat PREPARED BY: Andy Kass AICP, Senior Planner REPORT DATE: April 6, 2018 MEETING DATE: April 10, 2018 GENERAL INFORMATION Applicant: Jerry’s Homes, Inc. Owner: Jerry’s Homes, Inc. Owner’s Representative: Caleb Smith, P.E. with McClure Engineering Request: The applicant is requesting approval of a preliminary plat for a residential subdivision. Location and Size: Property is generally located east of SE L.A. Grant Parkway, North of Ashworth Road intersection containing approximately 23.18 acres more or less. AREA MAP ABOVE LEFT: Aerial of Property identifying the proposed plat (outlined in BLUE). April 6, 2018 2 of 3 LAND USES AND ZONING Location Existing Land Use Comprehensive Plan Current Zoning Property in Question Vacant – Undeveloped Neighborhood Residential R-2 (One and Two Family Residential) North Single Family Residential Neighborhood Residential R-2 (One & Two Family Residential) South Single Family Residential Neighborhood Residential A-1 (Agricultural) East Single Family Residential Neighborhood Residential R-2 (One & Two Family Residential) West Timberline School / Soccer Fields Neighborhood Residential A-1 (Agricultural) HISTORY The subject property is located east of SE L.A. Grant Parkway and north of Ashworth Road. In 2014, a preliminary plat for the property was approved by the City Council. Since then the ownership of the property has changed and the new owner has requested that a revised preliminary plat be considered for approval. The layout of the revised preliminary plat is very similar to that of what was approved in 2014. The main difference is that the number of lot proposed on the revised preliminary plat has increased. The original layout identified 54 single family lots and the revised layout identifies 63 single family lots. In addition to the change in number of lots, one less street will be continued to the east than what was originally proposed. PROJECT DESCRIPTION LOTS The preliminary plat identifies a total of 63 lots for single family residential development. The plat identifies the lots to be developed over the course of three phases beginning in the summer of 2018. The lots range in size from 8,040 square feet to 27,002 square feet. The proposed lot widths range from 65 feet to 135 feet, with most between 65 to 70 feet in width. All proposed lot widths and square footages meet the minimum requirements of the R-2 zoning district. Table 1 below summarizes the bulk regulations for the R-2 zoning district. Table 1: R-2 Zoning District Bulk Regulations Category Standard R-2 (minimum) Lot Area 8,000 square feet Lot Width 65 feet Front Yard Setback 30 feet Rear Yard Setback 30 feet Side Yard Setback 15 feet total (7 feet minimum) Outlot Z is located on the south side of the development and will be used for storm water retention purposes. Outlot Z will be owned and maintained by the homeowners association. April 6, 2018 3 of 3 STREETS AND TRAIL The preliminary plat identifies extensions of SE Esker Ridge Drive, SE Bluestem Drive, SE Clover Court, and SE Red Fern Drive. All planned streets will be public streets. SE Esker Ridge Drive will be 31 feet in width; all other streets will either be 26 or 29 feet in width. All lots will be accessed from the planned streets with the exception of Lot 33 which will be accessed directly off of SE L.A. Parkway. No trails are required to be constructed with this plat. Five foot sidewalks will be constructed along all proposed streets and along the lots that back-up to SE L.A. Grant Parkway. UTILITIES Utilities will be extended to service the proposed plat as part of the public improvements. Sanitary sewer service wil be provided by the lift station that was recently constructed on the south side of the plat. Water main will be extended from the north. Storm sewer will be provided throughout the plat and will route storm water to the pond which outlets to the south. PARKLAND The required amount of parkland for this development is 1.134 acres. The previous owner of the property satisfied the parkland dedication requirement for this plat with the approval of the final plat for Bluestem Plat 1. The previous owner dedicated a 2.5 acre parcel to the City that is located in the southwest corner of the Stone Prairie development on the west side of SE L.A. Grant Parkway. STAFF RECOMMENDATION All proposed lots meet the minimum requirements of the Zoning Ordinance and the use of the property is consistent with the Neighborhood Residential classification in the Comprehensive Plan. Staff recommends approval subject to remaining staff comments. 12345678910111213141516171819202122232425262728293031323940414344454647495051525455565758596061LOT 'A'OUTLOT 'Z'14131211100963534842383736353433PHASE IIIPHASE IIPHASE IPHASE II62SE BLUESTEM DR.SE CLOVER CT.SE RED FERN DR.SE ESKER RIDGE DR.SE LA GRANT PKWYSE TALLGRASS LANEPROJECT LOCATIONLA GRANT PKWY WESTOWN PKWY1GN-01NORTHN:\C3D Projects\WAK 2211013\Dwg\Design\Plans\Prelim Plat\GN-01.dwg DRAWING NO.CHECKED BYENGINEERSHEET NO.FIELD BOOK NO.DRAWN BYREVISIONSNOTICE:McClure Engineering Company waives any and allresponsibility and liability for problems which arise fromfailure to follow these Plans, Specifications, and theengineering intent they convey, or for problems which arisefrom failure to obtain and/or follow the engineers guidancewith respect to any errors, omissions, inconsistencies,ambiguities, or conflicts which are alleged.McCLURE ENGINEERING COMPANY 1360 NW 121ST. StreetClive, Iowa 50325515-964-1229fax 515-964-2370building strong communities.7WAUKEE, IOWAPRELIMINARY PLATBLUESTEM PLAT 2...4.2.20183.19.20187.18.20176.27.2017-C. SMITHJ. BECKERC. SMITHFEBRUARY 3, 20172211013-03Waukee, IowaPRELIMINARY PLATBLUESTEM PLAT 2OWNER/APPLICANTJERRY'S HOMES INC.10430 NEW YORK AVE., SUITE CURBANDALE, IOWA 50322(515) 727-0356ATTN: JAY COWANENGINEERMcCLURE ENGINEERING1360 NW 121ST STREETCLIVE, IOWA 50325(515) 964-1229ATTN: CALEB SMITHcsmith@mecresults.comLEGAL DESCRIPTIONNORTHDEVELOPMENT SCHEDULELAND COVERZONINGBULK REGULATIONSPRINCIPAL USESUTILITIESPRINCIPAL PERMITTED USES ARE FOR SINGLE FAMILYRESIDENTIAL DEVELOPMENT.WATER: CITY OF WAUKEESEWER: CITY OF WAUKEENATURAL GAS: CITY OF WAUKEEELECTRIC: MIDAMERICAN ENERGY COMPANYPHONE/CABLE: CENTURYLINK LOCAL NETWORK MEDIACOM COMMUNICATIONS CORP1-7INDEX OF PLAN SHEETSSheet No.Drawing No.Sheet Title1GN-01COVER SHEET2GN-02GENERAL LAYOUT AND DIMENSION PLAN3GN-03GENERAL LAYOUT AND DIMENSION PLAN4GR-01GRADING PLAN5GR-02GRADING PLAN6UT-01UTILITY PLAN7UT-02UTILITY PLAN501000GRAPHIC SCALE200SECTION, TOWNSHIP, RANGE004 - 078 - 026BENCHMARKBM #100 BURN BOLT ON HYDRANT, FIRST HYDRANT ONSOUTH SIDE OF TALLGRASS.ELEV: 1025.61PAVEMENTSE CLOVER COURT: 7" NON-REINFORCED PCCSE RED FERN DRIVE: 7" NON-REINFORCED PCCSE BLUESTEM DRIVE: 7" NON-REINFORCED PCCSE ESKER RIDGE DRIVE: 8" PCC WITH CD BASKETSBEING A PART OF LOT 1 OF SNYDER CORNER, AN OFFICIAL PLAT, LOCATED IN THE WESTHALF OF THE WEST HALF OF THE SOUTHWEST QUARTER OF SECTION 4, TOWNSHIP 78NORTH, RANGE 26 WEST OF THE 5TH P.M., CITY OF WAUKEE, DALLAS COUNTY, IOWABEING MORE PARTICULARLY DESCRIBED AS FOLLOWS:COMMENCING AT THE NORTHWEST CORNER OF SAID LOT 1; THENCE ALONG THE WESTLINE OF SAID LOT 1 S00°08'58”W, 310.54 FEET TO THE POINT OF BEGINNING; THENCEALONG SAID WEST LINE S00°08'39”W, 1644.23 FEET TO THE SOUTHWEST CORNER OFSAID LOT 1; THENCE ALONG THE SOUTH LINE OF SAID LOT 1 S89°49'37”E, 285.59 FEET;THENCE ALONG SAID SOUTH LINE N00°19'37”E, 76.62 FEET; THENCE ALONG SAIDSOUTH LINE N83°38'56”E, 330.00 FEET TO THE SOUTHEAST CORNER OF SAID LOT 1;THENCE ALONG THE EAST LINE OF SAID LOT 1 N00°09'31”E, 1628.31 FEET; THENCEN89°53'39”W, 120.00 FEET; THENCE S00°08'53”W, 20.67 FEET; THENCE N89°50'35”W,180.00 FEET; THENCE S00°21'24”W, 40.89 FEET; THENCE S83°33'01”W, 316.07 FEET TOTHE POINT OF BEGINNING. DESCRIBED AREA CONTAINS 23.18 ACRES AND IS SUBJECT TOEASEMENTS AND RESTRICTIONS OF RECORD.PARKLAND DEDICATIONREQUIRED: (# OF LOTS * 3 * 6 / 1000)= (62 * 3 * 6 / 1000)= 1.116 ACTHIS PARKLAND WAS DEDICATED AS PART OF THE STONE PRAIRIE DEVELOPMENT.LANDSCAPINGREQUIRED: 2 OVERSTORY, 2 ORNAMENTAL 3 EVERGREEN PER 50 LF OF BUFFER1106 LF BUFFER = 45 OVERSTORY, 45 ORNAMENTAL, 67 EVERGREENPROVIDED: 51 OVERSTORY, 54 ORNAMENTAL, 79 EVERGREEN1. MINIMUM LOT AREA:8,000 SF2. MINIMUM FLOOR AREA:950 SF FOR SINGLE STORY1,250 SF FOR TWO-STORY(MIN 600 SF FIRST FLOOR)350 SF PER LEVEL FOR SPLIT LEVEL950 SF PER STORY FOR SPLIT FOYER3. MINIMUM LOT WIDTH: 65 FT4. MINIMUM FRONT YARD:30 FT5. MINIMUM SIDE YARDS: TOTAL OF 15 FT, MIN. OF 7 FT PER SIDE6. MINIMUM REAR YARD:30 FT7. MAXIMUM HEIGHT:40 FT FOR PRINCIPAL BUILDING14 FT FOR ACCESSORY BUILDINGS8. MAXIMUM STORIES:3 STORIES FOR PRINCIPAL BUILDINGS1 STORY FOR ACCESSORY BUILDINGSR-2 (ONE & TWO-FAMILY RESIDENTIAL DISTRICT)GENERAL NOTESHOMEOWNERS ASSOCIATION WILL BE RESPONSIBLE FOR THE MAINTENANCE OF THEDETENTION BASIN AND LANDSCAPE BUFFER.GRADING: SUMMER 2018PRIVATE DETENTION & UTILITIES: SUMMER 2018PAVING FALL: 2018IMPERVIOUS AREA:88,091 SF (8.73%)OPEN AREA:921,452 SF (91.27%)TOTAL AREA:1,009,543 SF (100.0%) COCOCOCOCOCOCOCOCOCOTOP OF BERM: 1001.0NORMAL POOL: 995.5BOTTOM OF POND: 988.0BOTTOM OF POND: 988.0NORMAL POOL: 995.5TOP OF BERM: 1001.0COCO100-YR STORM: 999.7100-YR STORM: 999.7COCOCOCOCOCOCOCOCOCOCO29.0' B-B60.0' ROW70.0'ROW31.0'B-B60.0'ROW26.0'B-BS00°08'39"W 1644.23'S89°49'37"E 285.59'N00°19'37"E76.62'N83°38'56"E 330.00'N00°09'31"E 1628.31'13,070 SF4180,793 SF'OUTLOT Z'12,948 SF4010,454 SF3910,657 SF3811,546 SF458,325 SF378,127 SF448,502 SF3612,661 SF438,516 SF3513,842 SF429,171 SF348,040 SF2514,620 SF329,674 SF319,706 SF3010,583 SF2910,671 SF288,040 SF278,128 SF498,128 SF508,128 SF518,128 SF528,128 SF5311,592 SF468,127 SF4717,541 SF3376.6'145.7'685.9'76.6'76.6'147.9'76.6'147.9'147.9'87.5'160. 2 '147.9'162.0'147.9'225.3'75.6'147.9'64.6'65.0'23.6'41.2'87.7' 120.0'67.0'120.0' 120.0' 120.0'67.0'41.2'67.0'6.3'64.5'149.6'4.3'60.7'149.1'65.0'148.6'98.1'147.9'70.0'131.0'70.0'131.0'65.0'131.0'65.0' 21.6'43.4'130.0'30.8'34.2' 20.8'44.4'125.9'65.0' 49.6'14.9'37.2'82.4'15.4'83.6'15.2'74.1'130.6'78.6'46.0'127.3'52.8'78.8'21.7'48.1'120.1'92.9'67.5'42.6'174.3'155.1'92.9'37.9'6.0'125.0'155.1'65.0'125.0' 155.1'75.2'43.2'97.9' 155.1'61.8'125.0' 155.1' 105.3' 3 5 . 7 ' 125.0' 155.1' 125.0' 155.1'61.8'125.0' 155.1'61.8'125.0' 155.1'61.8'125.0' 155.1'65.0'125.0' 155.1'65.0'155.1'65.0'155.1'65.0'155.1'65.0'155.1'155.1'65.0'65.0'155.1'155.1'155.1'155.1'685.9'148.7'14.6'155.1'135.1'148.7'135.0'129.9'333.1'66.6' 92.9'82.0'105.0'14.6'92.9'76.6'685.9'155.1'155.1'PHASE IPHASE II61.8'12,424 SF10,366 SF2410,366 SF1622,333 SF1925,815 SF2114,601 SF200.4'69.6'200.3'34.2'67.8'67.8'67.0'67.0'87.5'67.0'87.5'95.0'39. 3'20.9'21.7'5 2.8'41. 4 '41.4'41.4'54.0 ' 2 1.7' 20.9' 34.2'95.0'39.3'62.5'65.0'190,123 SFLOT A8,128 SF488,040 SF2615,189 SF2320,268 SF22171.5'154.8'65.0'65.0'65.0'65.0'65.0'65.0'65.0'65.0'67.0'67.0'62.5'65.0'65.0'65.0'65.0'85.8'67.0'65.0'81.8'65.0'129.9'EXISTING 43.0' TELEPHONE EASEMENTBK:508 PG:505BK:2005 PG: 2182830' FRONTSETBACK (TYP.)30' FRONTSETBACK (TYP.)30' FRONTSETBACK (TYP.)30' FRONT SETBACK (TYP.) 30' REAR SETBACK (TYP.)30' REARSETBACK (TYP.)30' SANITARYSEWER EASEMENT35' REAR SETBACK (TYP.)30' REARSETBACK (TYP.)26.0' B-B37.0'B-BSE ESKER RIDGE DRIVE(8" PCC)SE CLOVER COURT(7" PCC)10' x 10' PUBLIC FACILITYAND USE EASEMENTS10.0' P.U.E.60.0' ROWR40.0'30' REAR SETBACK (TYP.)15' SANITARY SEWER EASEMENT (TYP.)10.0' OVERLANDFLOWAGE EASEMENT10.0' SANITARYSEWER EASEMENT20.0' STORMSEWER EASEMENT7.5' SIDE SETBACK (TYP.)7.5' SIDE SETBACK (TYP.)35.0' TEMPORARYCONSTRUCTION EASEMENT7.5' SIDE SETBACK (TYP.) 7.5' SIDE SETBACK (TYP.) 7.5' SIDE SETBACK (TYP.) 7.5' SIDE SETBACK (TYP.)20.0' OVERLANDFLOWAGE EASEMENT30' REAR YARDSETBACK (TYP.)7.5' SIDE SETBACK (TYP.)7.5' SIDE SETBACK (TYP.)10.0' SNOWEASEMENT10.0' SNOWEASEMENTSTORM SEWEREASEMENT20' x 10'P.U.E.20' x 10'P.U.E.20' x 10'P.U.E.20' x 10'P.U.E.R25.0'R25.0'R25.0'R25.0'R25.0'R25.0'20.0' STORM SEWER ANDOVERLAND FLOWAGE EASEMENT20' x 10'P.U.E.20' x 10'P.U.E.20' x 10'P.U.E.20' x 10'P.U.E.R40.0'R40.0'R40.0'20.0' STORM SEWER ANDOVERLAND FLOWAGE EASEMENT10.0' SANITARYSEWER EASEMENT10.0' SANITARYSEWER EASEMENT30' x 40' STORM ANDSANITARY EASEMENT40.0'30.0'STORM SEWEREASEMENT45.0' INGRESS /EGRESS EASEMENT25.0' LANDSCAPEBUFFER EASEMENTSE BLUESTEM DRIVE(7" PCC)SE LA GRANT PKWY2GN-02GENERAL LAYOUTN:\C3D Projects\WAK 2211013\Dwg\Design\Plans\Prelim Plat\GN-02.dwg DRAWING NO.CHECKED BYENGINEERSHEET NO.FIELD BOOK NO.DRAWN BYREVISIONSNOTICE:McClure Engineering Company waives any and allresponsibility and liability for problems which arise fromfailure to follow these Plans, Specifications, and theengineering intent they convey, or for problems which arisefrom failure to obtain and/or follow the engineers guidancewith respect to any errors, omissions, inconsistencies,ambiguities, or conflicts which are alleged.1360 NW 121ST. StreetClive, Iowa 50325515-964-1229fax 515-964-2370building strong communities.7...4.2.20183.19.20187.18.20176.27.2017-C. SMITHJ. BECKERC. SMITHFEBRUARY 3, 20172211013-03Waukee, IowaPRELIMINARY PLATBLUESTEM PLAT 212345678910111213141516171819202122232425262728293031323940414344454647495051525455565759606162SE ESKER RIDGE DR.OUTLOT 'Z'63534842383736353433SE CLOVER CT.SE RED FERN DR.SE BLUESTEM DR.58NORTHNOTE:1) OUTLOT Z SHALL BE MAINTAINED BY BLUESTEM HOMEOWNERS ASSOCIATION.2) 10' x 20' P.U.E. HAS BEEN ADDED AT EVERY OTHER LOT LINE FOR ELECTRICALBOXES. (14) P.U.E. BUMP OUTS HAVE BEEN ADDED.3) SE ESKER RIDGE DRIVE SHALL HAVE A 37' PAVING WIDTH FOR 150' MEASUREDFROM THE CURB RETURN, THEN TAPER TO 31' PAVING AT 20:1.4) EXISTING FARM FENCING THAT IS LOCATED WITHIN THIS PLAT WILL NEED TOBE REMOVED.5) LOT A, WHICH INCLUDES 10' OF ADDITIONAL ROW ALONG SE L.A. GRANTPKWY, SHALL BE DEDICATED TO THE CITY.LANDSCAPING INDEXORNAMENTALEVERGREENOVERSTORY20400GRAPHIC SCALE80 COCOCOCOCOCOCOCOCOCOCOCOCOCOCOCOCOCOCOCOCOCOCOSE TALLGRASS LANE60.0'ROW26.0'B-B0102030405060708141312111009SE LA GRANT PKWYN89°53'39"W120.00'S00°08'53"W20.67'N89°50'35"W180.00'N00°09'31"E 1628.31'S00°21'24"W40.89'S83°33'01"W 316 . 0 7 '10,872 SF18,040 SF158,040 SF148,040 SF139,932 SF28,440 SF638,461 SF628,551 SF618,641 SF608,754 SF588,128 SF518,128 SF528,128 SF538,128 SF548,129 SF55128.9'45.1'127.4'77.5'126.2'66.0'87.5'244.0'262.0 ' 158.5 '164.2'191.5'6.4'89.9'169.8'132.7'87.5'67.0'39.5'70.0'120.0'120.0'120.0'27.5'120.0'67.0'87.5'160.8'183.7'160.2'162.0'125.0'125.0'125.1'125.1'125.1'125.1'70.0'70.0'53.1'124.1'70.0'122.8' 121.5' 120.2'9.0'40.6'PHASE IIIPHASE II8,278 SF568,728 SF598,754 SF57125.1' 125.1'12,424 SF1715,208 SF1826,325 SF710,366 SF10,366 SF1622,333 SF1927,002 SF618,968 SF510,846 SF48,371 SF310,366 SF1213,264 SF1115,552 SF1023,722 SF914,635 SF814,601 SF2034.2'87.5'87.5'95.0'39.3'20.9'21.7'52.8'41.4'41.4'41.4'54.0'21.7'20.9'34.2'95.0'39.3'62.5'67.0'67.0'67.0'62.5'39 . 3' 95.0'34.2'20.9'21.7'51.4' 4 1. 4 '41.4'41.4'48.7 ' 28.4' 20.9'29.5'100.1'38.8'63.0'66.0'77.5'47.0'40.1'154.8'137.2'138.4'155.1'202.5'46.7' 177.7' 71.9' 9.7'40.9'119.9'60.0'20.7'120.0'70.3'70.0'70.0'70.0'70.0'70.0'70.0'66.2'65.0'65.0'65.0'65.0'65.0'65.0'65.0'65.0'65.0'65.0'66.2'70.0'70.0'16.9'30' FRONTSETBACK (TYP.)30' REAR SETBACK (TYP.)EXISTING 20.0' STORMSEWER EASEMENTEXISTING 20.0' STORMSEWER EASEMENTEXISTING 30.0' OVERLANDFLOWAGE EASEMENTEXISTING 10.0' P.U.E. ANDTRAIL EASEMENTEXISTING 15.0'OVERLAND FLOWAGEEASEMENTEXISTING 10.0' P.U.E.26.0'B-BSE BLUESTEM DRIVE(7" PCC)SE RED FERN DR.(7" PCC)SE CLOVER COURT(7" PCC)50' FUTUREHALF ROW40' EXISTINGHALF ROW10' ROW DEDICATION60.0'ROW15' SANITARY SEWER EASEMENT (TYP.)10.0' OVERLANDFLOWAGE EASEMENT30' REAR SETBACK (TYP.)30' REARSETBACK (TYP.)OVERLAND FLOWAGE & STORM SEWER EASEMENT10.0' OVERLANDFLOWAGE EASEMENT30.0' STORMSEWER EASEMENT30' FRONTSETBACK (TYP.)30' REARSETBACK (TYP.)7.5' SIDE SETBACK (TYP.) 7.5' SIDE SETBACK (TYP.)30' REAR YARDSETBACK (TYP.)R25.0'R25.0'29.0' B-B60.0' ROW7.5' SIDE SETBACK (TYP.) 7.5' SIDE SETBACK (TYP.)10.0' SNOWEASEMENT35.0' TEMPORARYCONSTRUCTION EASEMENT30' FRONTSETBACK (TYP.)7.5' SIDE SETBACK (TYP.)7.5' SIDE SETBACK (TYP.)10.0' SNOWEASEMENTR25.0'R25.0'20' x 10'P.U.E.20' x 10'P.U.E.20' x 10'P.U.E.R40.0'R40.0'R40.0'20' x 10'P.U.E.20.0' STORM SEWER ANDOVERLAND FLOWAGE EASEMENTR40.0'R40.0'R40.0'20' x 10'P.U.E.20' x 10'P.U.E.20' x 10'P.U.E.EXISTING 43.0' TELEPHONE EASEMENTBK: 508 PG: 50520.0' STORM SEWER ANDOVERLAND FLOWAGE EASEMENT25.0' LANDSCAPEBUFFER EASEMENT3GN-03GENERAL LAYOUTN:\C3D Projects\WAK 2211013\Dwg\Design\Plans\Prelim Plat\GN-02.dwg DRAWING NO.CHECKED BYENGINEERSHEET NO.FIELD BOOK NO.DRAWN BYREVISIONSNOTICE:McClure Engineering Company waives any and allresponsibility and liability for problems which arise fromfailure to follow these Plans, Specifications, and theengineering intent they convey, or for problems which arisefrom failure to obtain and/or follow the engineers guidancewith respect to any errors, omissions, inconsistencies,ambiguities, or conflicts which are alleged.1360 NW 121ST. StreetClive, Iowa 50325515-964-1229fax 515-964-2370building strong communities.7...4.2.20183.19.20187.18.20176.27.2017-C. SMITHJ. BECKERC. SMITHFEBRUARY 3, 20172211013-03Waukee, IowaPRELIMINARY PLATBLUESTEM PLAT 212345678910111213141516171819202122232425262728293031323940414344454647495051525455565759606162SE ESKER RIDGE DR.OUTLOT 'Z'63534842383736353433SE CLOVER CT.SE RED FERN DR.SE BLUESTEM DR.58NORTHNOTE:1) OUTLOT Z SHALL BE MAINTAINED BY BLUESTEM HOMEOWNERS ASSOCIATION.2) 10' x 20' P.U.E. HAS BEEN ADDED AT EVERY OTHER LOT LINE FOR ELECTRICALBOXES. (14) P.U.E. BUMP OUTS HAVE BEEN ADDED.3) SE ESKER RIDGE DRIVE SHALL HAVE A 37' PAVING WIDTH FOR 150' MEASUREDFROM THE CURB RETURN, THEN TAPER TO 31' PAVING AT 20:1.4) EXISTING FARM FENCING THAT IS LOCATED WITHIN THIS PLAT WILL NEED TOBE REMOVED.5) LOT A, WHICH INCLUDES 10' OF ADDITIONAL ROW ALONG SE L.A. GRANTPKWY, SHALL BE DEDICATED TO THE CITY.LANDSCAPING INDEXORNAMENTALEVERGREENOVERSTORY20400GRAPHIC SCALE80 20212223242526272829303132394041434445464749505152LOT 'A'OUTLOT 'Z'4842383736353433PHASE IPHASE IICOCOCOTOP OF BERM: 1001.0NORMAL POOL: 995.5BOTTOM OF POND: 988.0BOTTOM OF POND: 988.0NORMAL POOL: 995.5TOP OF BERM: 1001.0100-YR STORM: 999.7100-YR STORM: 999.7COCOCOCOCOCOCOCO1 0 1 2 1014101 2 10121012101410161018100810101012101210101012101410101008 1 0 0 8 10121014101610181010100810021004 101010101010101210141016SWALESWALESWALE101 81018 1014101410141014 10121014 1016 1024 1024 1026 1024 1026 1012 1014 10101010101010101020101210141016101833.33%25.00%33.33%33.33%24.93%25.00%26.42%25.15%25.60%SE CLOVER CT(7" PCC)SE ESKER RIDGE DR.(8" PCC)SE BLUESTEM DR.(7" PCC)990100010101020992994996998100210041006100810121014101610189901000988992994996998990 1000 1010 988 992 994 996 998 10021004 1006 1008 10121004100610081004 1006 1008 1010 10201008 1012101410161018100610081008MOE: 1002.00MOE: 1013.00MOE: 1013.00MOE: 1006.25MOE: 1006.25MOE: 1006.25MOE: 1002.00MOE: 1002.00MOE: 1002.00MOE: 1002.00MOE: 1002.00MOE: 1002.00MOE: 1002.00MOE: 1002.00MOE: 1002.00MOE: 1010.50MOE: 1010.50MOE: 1010.50MOE: 1010.50MOE: 1010.50MOE: 1010.50MOE: 1013.00MOE: 1013.00MOE: 1013.00MOE: 1013.00MOE: 1013.00MOE: 1010.50MOE: 1010.50MOE: 1010.50MOE: 1010.50MOE: 1010.50MOE: 1010.50DETENTION BASINTOP OF BERM: 1001.0100-YR ELEVATION: 999.7TYPICAL POOL: 995.5BOTTOM OF POND: 988.0OVERFLOWOVERFLOWOVERFLOW1 0 1 2 . 7 5 F G 1 0 1 2 . 5 5 F G1012.51 FG1012.51 FG1012.82 FG1013.37 FG1013.37 FG1012.89 FG1012.61 FG1012.50 FG1 0 1 2 . 5 0 F G1012.75 FG1 0 0 9 . 7 1 F G1006.25 FG1006.25 FG1005.04 FG 1 0 1 1 . 1 1 F G 1 0 1 2 . 2 7 F G 1 0 1 3 . 0 1 F G 1013.46 FG1 0 0 9 . 9 2 F G 1 0 0 9 . 1 5 F G 1008.60 FG1009.48 FG1011.23 FG1013.97 FG1 0 0 6 . 1 5 F G1002.73 FG1001.04 FG1001.64 FG1001.27 FG1001.00 FG1001.01 FG1006.92 FG1007.63 FG1 0 0 7 . 3 3 F G 1 0 0 7 . 9 4 F G 1008.47 F G 1009.78 FG1007.50 FG1011.09 FG1012.39 FG1016.12 FG1014.87 FG1014.33 FG1013.16 FG1012.89 FG1010.82 FG1 0 0 9 . 5 2 F G 1015.54 FG1012.16 FG1010.10 FG1008.78 FG1008.73 FG1009.79 FG1007.66 FG1007.30 FG1008.22 FG1009.32 FG1010.79 FG1011.93 FG1012.80 FG1013.14 FG1008.00 FG1008.30 FG1008.54 FG1016.90 FG1014.86 FG1014.34 FG1013.15 FG1013.14 FG1012.62 FG1013.82 FG1014.09 FG1014.22 FG1014.22 FG1012.78 FG1013.14 FG1013.11 FG1013.75 FG1013.01 FG1011.67 FG1009.59 FG1009.30 FG1009.71 FG1008.19 FG1008.40 FG1007.20 FG1004.56 FG1005.17 FG1014.60 FG1012.13 FG1010.49 FG1011.70 FG1011.52 FG1010.65 FG 1 0 1 1 . 4 6 F G 1014.73 FG1018.78 FG1021.16 FG1016.50 EG1009.56 EG1000.00 EG999.06 EG1001.37 EG1006.78 EG1005.40 EG1006.13 FG1009.56 FG1005.52 FG1005.31 FG 1 0 0 6 . 1 4 F G 1008.19 FG1011.58 FG1018.76 FG1020.45 FG 1 0 2 1 . 2 6 F G1020.37 FG1 0 2 0 . 8 3 F G 1022.34 FG1018.98 FG1016.88 FG1016.16 FGCRITICAL OVERFLOW1012.10 FGCRITICAL OVERFLOW1012.36 FGCRITICAL OVERFLOW1008.02 FGCRITICAL OVERFLOW1008.07 FGCRITICAL OVERFLOW1007.91 FGCRITICAL OVERFLOW1009.48 FGSHADED AREA REPRESENTS100-YR STORM EXTENTS1006.00 EG11.4'1014.00 FG18.6'2.15% 2.75% 2.84%2.08%2.91%3.11% 3.31%2.00%2.00%2.10%2.26%2.26%4. 3 3 % 5. 5 1 %2.73%3.08%4.45%3.23%4.31%4.4 7 %4.57%2. 6 1 % 3. 6 6 %2.59%3.69%6.75%3.13% 3 . 9 5%2.51% 6.00%EXISTING POND(CURRENTLY A WET, SEDIMENT BASIN; WHEREAS FINALCONDITION IS PROPOSED TO BE DRY POND)1001.10 FG1004.00 FG1002.00 FG1000.00 FG996.00 FG14.7'14.5'14.2'12.0'1001.51 FG1013.62 FG1012.01 FG1010.00 FG1008.00 FG1008.00 FG1008.00 FG1010.00 FG5'5'5'5.0'5'5'2.00 % 2.34% 2.14%3.58%14.34%1016.00 FG50.3'2.00%5.10 % 2.47%2.00%2.24%2.00 %2.10%4.25%3. 1 3%2.48%4.09% 1012 1014 1014 4GR-01GRADING PLAN20400GRAPHIC SCALE80NORTHN:\C3D Projects\WAK 2211013\Dwg\Design\Plans\Prelim Plat\GR-01.dwg DRAWING NO.CHECKED BYENGINEERSHEET NO.FIELD BOOK NO.DRAWN BYREVISIONSNOTICE:McClure Engineering Company waives any and allresponsibility and liability for problems which arise fromfailure to follow these Plans, Specifications, and theengineering intent they convey, or for problems which arisefrom failure to obtain and/or follow the engineers guidancewith respect to any errors, omissions, inconsistencies,ambiguities, or conflicts which are alleged.1360 NW 121ST. StreetClive, Iowa 50325515-964-1229fax 515-964-2370building strong communities.7...4.2.20183.19.20187.18.20176.27.2017-C. SMITHJ. BECKERC. SMITHFEBRUARY 3, 20172211013-03Waukee, IowaPRELIMINARY PLATBLUESTEM PLAT 212345678910111213141516171819202122232425262728293031323940414344454647495051525455565759606162SE ESKER RIDGE DR.OUTLOT 'Z'63534842383736353433SE CLOVER CT.SE RED FERN DR.SE BLUESTEM DR.58 12345678910111213141516171819202122232425505152545556575859606101141312111009SE LA GRANT PKWY6353PHASE IIIPHASE II62COCOCOCOCOCOCOCOCOSE TALLGRASS LANE101410161020 1022 102410261028 10201016101610 1 8 10181012 1012101210141016101810201012101210141016101810221024102610201014 1016 1018 1022101410 2 0 10221020 101 8 1022 1024 1026 1028 10281012SWALE10181018 1020 101 8 1022 1024 1026 1028 101410141014 10141016 1016 SWALESWALESWALESWALETEMPORARY SWALE102010141016101810221024102610141014 1016 10121014 1016 1030 1030 10241024102610261026 1026 1026 1026 10261028 1028 10281028 1032 1026SE BLUESTEM DR.(7" PCC)SE RED FERN DR.(7" PCC)SE CLOVER CT(7" PCC)MOE: 1013.00MOE: 1013.00MOE: 1013.00MOE: 1013.00MOE: 1010.50MOE: 1010.50MOE: 1010.50MOE: 1010.50MOE: 1010.50MOE: 1013.00MOE: 1013.00MOE: 1013.00MOE: 1014.60MOE: 1014.60MOE: 1014.60MOE: 1014.60MOE: 1014.60MOE: 1014.60MOE: 1014.60MOE: 1014.60MOE: 1014.60MOE: 1014.60MOE: 1014.60MOE: 1021.00MOE: 1021.00MOE: 1021.00MOE: 1021.00MOE: 1021.00MOE: 1021.00TEMPORARY SWALEO V E R F L OW 1025.29 FG1023.80 FG1 0 2 2 . 2 6 F G1020.87 FG1 0 1 9 . 4 7 F G 1 0 1 7 . 8 4 F G 1 0 1 6 . 0 6 F G1014.80 FG1013.62 FG1012.91 FG1012.75 FG1012.55 FG1012.51 FG1012.51 FG1 0 2 5 . 1 7 F G 1 0 2 2 . 5 5 F G 1 0 2 0 . 3 2 F G 1 0 1 8 . 1 9 F G 1016.84 FG1 0 1 7 . 8 4 F G 1020.57 FG1020.19 FG1 0 1 5 . 1 4 F G 1 0 1 4 . 4 7 F G1013.80 FG1013.13 FG1012.82 FG1013.37 FG1013.37 FG1012.89 FG1012.61 FG1013.14 FG1013.79 FG1014.44 FG1015.10 FG1015.80 FG1017.09 FG1019.38 FG1021.74 FG1024.11 FG1026.37 FG1013.01 FG1013.46 FG1016.12 FG1014.87 FG1014.33 FG1013.16 FG1012.89 FG1010.82 FG1009.52 FG1013.14 FG1016.90 FG1014.86 FG1014.34 FG1013.15 FG1013.14 FG1012.62 FG 1014.23 FG1014.55 FG 1013.69 FG1012.35 FG1011.30 FG 1 0 1 2 . 7 9 F G 1 0 1 3 . 8 2 F G 1013.30 FG1015.95 FG1016.08 FG 1021.58 FG1018.37 FG1 0 2 1 . 1 8 F G 1022.30 FG1 0 2 1 . 5 2 F G 1018.14 FG1018.52 FG1019.11 FG1019.33 FG1021.38 FG1022.07 FG1014.82 FG1015.19 FG1015.99 FG1018.26 FG1 0 2 1 . 2 8 F G 1025.80 FG1024.94 FG1027.26 FG1025.11 FG1022.87 FG1020.73 FG1018.73 FG1017.29 FG1016.29 FG1015.50 FG1014.74 FG1014.34 FG1013.82 FG1014.09 FG1014.22 FG1014.22 FG1012.78 FG1013.14 FG1013.11 FG1011.52 FG1011.46 FG1014.73 FG 1018.78 FG1022.34 FG1023.23 FG1024.07 FG1018.98 FG1016.88 FG1017.77 FG1016.16 FG1017.14 FG1026.54 EGCRITICAL OVERFLOW1012.10 FG1022.61 EGCRITICAL OVERFLOW1012.36 FG1021.58 EG1022.89 EG1021.29 EG1021.28 EG1027.00 EG1026.97 EG1027.10 EG1027.66 EG1028.98 EG1028.77 EG1019.32 FG1019.07 FG1018.68 FG1018.52 FG1018.14 FG1017.79 FG1016.84 FG1015.79 FGCRITICAL OVERFLOW1013.61 FGCRITICAL OVERFLOW1020.04 FGSHADED AREA REPRESENTS100-YR STORM EXTENTSSHADED AREA REPRESENTS100-YR STORM EXTENTSOVERFLOWOVERFLOW OVERFLOWOVERFLOW1014.00 FG1 0 1 6 . 0 0 F G 1 0 1 8 . 0 0 F G 1020.01 FG1 0 2 2 . 0 1 F G 1024.03 FG1 0 2 6 . 0 0 F G10.5'5'5'5'5'5'5'5'1018.00 FG1018.00 FG5'5'1 0 1 2 . 0 0 F G1012.01 FG1012.00 FG1014.00 FG1016.01 FG5'5'4.53% 3. 9 3 %3.11%2.40%2.83%2.50%2.51%2.00%2.12%2.42%2.04%2.15%2.75%2.84%4.45%3.23%3.13%3.95%4.10%3.16%3.86%2.51%3.01%5.46%4.61%3.34%2. 4 6 % 4. 0 5 % 4.22 % 2.52% 2.5 7 %2.29%3.51%4.66%2.95% 4.4 4 %4.69%EXISTING POND(CURRENTLY A WET, SEDIMENT BASIN; WHEREAS FINALCONDITION IS PROPOSED TO BE DRY POND)1010.00 FG5'5'5'1015.48 FG2.34%1016.00 FG50.3'2.24%2.17%2.00%1013.43 FG5'2.62%2.00%5.22%2.08%2.00%2.09%2.39%2.24%2.02%1020.89 FG14.7'1021.69 FG6.37%2.00%1 0 1 9 . 9 3 F G31.4'2.03%1021.29 FG1020 1016 1018 1016 1018 1018 1012 10141014 5GR-02GRADING PLAN20400GRAPHIC SCALE80NORTHN:\C3D Projects\WAK 2211013\Dwg\Design\Plans\Prelim Plat\GR-01.dwg DRAWING NO.CHECKED BYENGINEERSHEET NO.FIELD BOOK NO.DRAWN BYREVISIONSNOTICE:McClure Engineering Company waives any and allresponsibility and liability for problems which arise fromfailure to follow these Plans, Specifications, and theengineering intent they convey, or for problems which arisefrom failure to obtain and/or follow the engineers guidancewith respect to any errors, omissions, inconsistencies,ambiguities, or conflicts which are alleged.1360 NW 121ST. StreetClive, Iowa 50325515-964-1229fax 515-964-2370building strong communities.7...4.2.20183.19.20187.18.20176.27.2017-C. SMITHJ. BECKERC. SMITHFEBRUARY 3, 20172211013-03Waukee, IowaPRELIMINARY PLATBLUESTEM PLAT 212345678910111213141516171819202122232425262728293031323940414344454647495051525455565759606162SE ESKER RIDGE DR.OUTLOT 'Z'63534842383736353433SE CLOVER CT.SE RED FERN DR.SE BLUESTEM DR.58 20212223242526272829303132394041434445464749505152LOT 'A'OUTLOT 'Z'4842383736353433PHASE IPHASE IICOCOCOCOCOCOCOCOCOCOTOP OF BERM: 1001.0NORMAL POOL: 995.5BOTTOM OF POND: 988.0BOTTOM OF POND: 988.0NORMAL POOL: 995.5TOP OF BERM: 1001.0COCO100-YR STORM: 999.7100-YR STORM: 999.7COCOCOCOCOCOCOCOCOCO150' HYDRANTRADIUS (TYP.)SE LA GRANT PKWYHYDRANT ASSEMBLY (HYD-05)HYDRANT ASSEMBLY (HYD-03)HYDRANT ASSEMBLY (HYD-04)HYDRANT ASSEMBLY (HYD-02)8" GATE VALVE (GV-06)8" GATE VALVE (GV-05)8" GATE VALVE (GV-04)SE BLUESTEM DRIVE(7" PCC)WATER SERVICE TO BEBORED UNDER LA GRANT PARKWAY.DETENTION BASIN8" GATE VALVE (GV-02)CO-201(TYPE 8" DIA., CLEANOUT)INT-202(TYPE SW-503)STMH-201(TYPE SW-401)INT-301(TYPE SW-503)INT-304A(TYPE SW-505)INT-304(TYPE SW-506L)INT-303(TYPE SW-506L)SSMH-306, (SW-301)RIM: 1015.64FL OUT: 1002.57 (E)SSMH-204, (SW-301)RIM: 1016.35FL OUT: 1002.80 (E)SSMH-202, (SW-301)RIM: 1013.04FL IN: 999.63 (W)FL IN: 999.36 (N)FL OUT: 999.26 (S)SSMH-203, (SW-301)RIM: 1012.88FL IN: 997.78 (N)FL OUT: 997.68 (S)SSMH-304(TYPE SW-301)SSMH-301, (SW-301)RIM: 1008.17FL IN: 995.48 (W)FL IN: 995.48 (E)FL IN: 995.48 (N)FL OUT: 994.98 (S)INT-303A(TYPE SW-505)SSMH-305, (SW-301)RIM: 1008.41FL IN: 997.30 (W)FL OUT: 997.20 (E)STMH-301(TYPE SW-401)STMH-303(TYPE SW-401)FES-302(TYPE 48" FES)EX-303, (SW-301)RIM: 1002.72FL IN: 990.78 (NE)SSMH-302, (SW-301)RIM: 1007.38FL IN: 992.30 (N)FL OUT: 992.20 (SW)STMH-304(TYPE SW-401)CO-301(TYPE 8" DIA., CLEANOUT)INT-305(TYPE SW-512, 24" BEEHIVE)22.5° BENDFT-06STMH-302(TYPE SW-401)INT-302(TYPE SW-506 MODIFIED)8" CROSSFT-03INT-301A(TYPE SW-501)INT-302A(TYPE SW-506L)45° BENDFT-0145° BENDFT-02HYDRANT ASSEMBLY (HYD-10)MAILBOX PADLOCATIONMAILBOX PADLOCATIONFES-301(TYPE 42" FES)150' HYDRANTRADIUS (TYP.)SE ESKER RIDGE DR. (8" PCC)SE CLOVER CT.(7" PCC)360 LF OF 6"SUBDRAIN375 LF OF 6"SUBDRAIN95 LF OF 6"SUBDRAINWEIRSTRUCTURECRITICALCROSSINGCLEANOUTCLEANOUTCLEANOUTCLEANOUTCLEANOUTCLEANOUTCLEANOUTHYDRANT ASSEMBLY (HYD-01)6UT-01UTILITY PLANNORTHN:\C3D Projects\WAK 2211013\Dwg\Design\Plans\Prelim Plat\UT-01.dwg DRAWING NO.CHECKED BYENGINEERSHEET NO.FIELD BOOK NO.DRAWN BYREVISIONSNOTICE:McClure Engineering Company waives any and allresponsibility and liability for problems which arise fromfailure to follow these Plans, Specifications, and theengineering intent they convey, or for problems which arisefrom failure to obtain and/or follow the engineers guidancewith respect to any errors, omissions, inconsistencies,ambiguities, or conflicts which are alleged.1360 NW 121ST. StreetClive, Iowa 50325515-964-1229fax 515-964-2370building strong communities.7...4.2.20183.19.20187.18.20176.27.2017-C. SMITHJ. BECKERC. SMITHFEBRUARY 3, 20172211013-03Waukee, IowaPRELIMINARY PLATBLUESTEM PLAT 212345678910111213141516171819202122232425262728293031323940414344454647495051525455565759606162SE ESKER RIDGE DR.OUTLOT 'Z'63534842383736353433SE CLOVER CT.SE RED FERN DR.SE BLUESTEM DR.5820'40'0GRAPHIC SCALE80' 123456789101112131415161718192021222324255051525455565758596061010203141312111009SE LA GRANT PKWY6353PHASE IIIPHASE II62COCOCOCOCOCOCOCOCOCOCOCOCOCOCOCOCOCOCOCOCOCOCO24IN RCP FESFL=1016.62SE TALLGRASS LANEEXISTING60.0' ROWEXISTING31.0' B-BEXISTING80.0' ROWEXISTING35' B-BHYDRANT ASSEMBLY (HYD-07)HYDRANT ASSEMBLY (HYD-09)HYDRANT ASSEMBLY (HYD-06)8" GATE VALVE (GV-08)8" GATE VALVE (GV-07)8" GATE VALVE (GV-06)CO-101(TYPE 8" DIA, CLEANOUT)STMH-102(TYPE SW-401)CO-102(TYPE 8" DIA., CLEANOUT)INT-102(TYPE SW-506R)INT-102A(TYPE SW-501)INT-103A(TYPE SW-505)INT-103(TYPE SW-503)STMH-103(TYPE SW-401)CO-201(TYPE 8" DIA., CLEANOUT)INT-202(TYPE SW-503)INT-202A(TYPE SW-501)INT-201(TYPE SW-506R)INT-201A(TYPE SW-505)STMH-201(TYPE SW-401)SSMH-101, (SW-301)RIM: 1027.50FL OUT: 1015.87 (S)SSMH-104, (SW-301)RIM: 1018.84FL OUT: 1006.14 (E)SSMH-102, (SW-301)RIM: 1016.32FL IN: 1002.97 (W)FL IN: 1004.44 (N)FL OUT: 1002.87 (S)SSMH-204, (SW-301)RIM: 1016.35FL OUT: 1002.80 (E)SSMH-202, (SW-301)RIM: 1013.04FL IN: 999.63 (W)FL IN: 999.36 (N)FL OUT: 999.26 (S)SSMH-203, (SW-301)RIM: 1012.88FL IN: 997.78 (N)FL OUT: 997.68 (S)HYDRANT ASSEMBLY (HYD-08)INT-203(TYPE SW-512, 24" BEEHIVE)INT-101(TYPE SW-512, 30" BEEHIVE)HYDRANT ASSEMBLY (HYD-11)8" TEEFT-058" GATE VALVE (GV-10)SSMH-201(TYPE SW-301)HYDRANT ASSEMBLY (HYD-10)8" TEEFT-04MAILBOX PADLOCATIONMAILBOX PADLOCATIONMAILBOX PADLOCATION150' HYDRANTRADIUS (TYP.)SE CLOVER CT.(7" PCC)SE RED FERN DR.(7" PCC)SE BLUESTEM DRIVE(7" PCC)360 LF OF 6"SUBDRAIN235 LF OF 6"SUBDRAIN345 LF OF 6"SUBDRAIN225 LF OF 6"SUBDRAIN305 LF OF 6"SUBDRAINHYDRANT ASSEMBLY (HYD-12)CLEANOUTCLEANOUTCLEANOUTCLEANOUTCLEANOUTCLEANOUT7UT-02UTILITY PLANNORTHN:\C3D Projects\WAK 2211013\Dwg\Design\Plans\Prelim Plat\UT-01.dwg DRAWING NO.CHECKED BYENGINEERSHEET NO.FIELD BOOK NO.DRAWN BYREVISIONSNOTICE:McClure Engineering Company waives any and allresponsibility and liability for problems which arise fromfailure to follow these Plans, Specifications, and theengineering intent they convey, or for problems which arisefrom failure to obtain and/or follow the engineers guidancewith respect to any errors, omissions, inconsistencies,ambiguities, or conflicts which are alleged.1360 NW 121ST. StreetClive, Iowa 50325515-964-1229fax 515-964-2370building strong communities.7...4.2.20183.19.20187.18.20176.27.2017-C. SMITHJ. BECKERC. SMITHFEBRUARY 3, 20172211013-03Waukee, IowaPRELIMINARY PLATBLUESTEM PLAT 212345678910111213141516171819202122232425262728293031323940414344454647495051525455565759606162SE ESKER RIDGE DR.OUTLOT 'Z'63534842383736353433SE CLOVER CT.SE RED FERN DR.SE BLUESTEM DR.5820'40'0GRAPHIC SCALE80'