Loading...
HomeMy WebLinkAbout2022-02-07-J12 Converge NW Plat 1_Site Plan AGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: February 7, 2022 AGENDA ITEM: Consideration of approval of a resolution approving a site plan for Converge NW Plat 1 (350 NW 6th Street) FORMAT: Resolution SYNOPSIS INCLUDING PRO & CON: Hubbell Development Services, requests approval of a site plan for a multi-family residential complex. The property is 15-acres in area and is located south of NW Sunrise Drive and east of NW 10th Street. The site plan includes three (3) apartment buildings with 60 units per building and eight (8) townhome buildings. The townhome buildings will have three (3) to five (5) units per building. All apartment and townhome units will be for rent. In addition to the residential buildings, the site plan shows four (4) detached garage buildings. Access to the site will be provided from NW 6th Street. The required amount of parking is being provided across the site. All utilities and streets internal to the site will be privately owned and maintained. The applicant has provided elevations for the proposed building on the site. The design and materials are consistent with the Site Plan Ordinance. A total of 2.3-acres of parkland are required based upon the number of units shown on the site plan. The applicant has proposed to satisfy the parkland dedication requirement with a fee in lieu of land dedication. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning Commission reviewed this project at the January 11, 2022 Commission Meeting and recommended approval subject to remaining staff comments: Approval of a Site Plan for Converge NW Plat 1 Director of Development, Andy Kass, introduced the request for approval of a Preliminary Plat as submitted by the applicant Hubbell Development Services. The subject property is generally located south of NW Sunrise Drive and east of NW 10th Street, containing approximately 15 acres. Mr. Kass advised that the project involves the construction of three apartment buildings, 4 garage structures, 8 townhome buildings, and one clubhouse. Each apartment building will contain 60 units ranging in size from 673 square feet to 1,383 square feet. Each townhome building will contain 3-5 townhomes ranging in size from 1,634 square feet to 2,028 square feet. All units in the development are intended for rental use and are served by a shared clubhouse approximately 3.154 square feet in J12 size with an outdoor pool. Two trash enclosures are located on site to serve the apartments, each town home unit will have individual trash services. Mr. Kass explained that access to the site is provided from two points off of NW 6th Street with all internal streets and access drives being privately owned and maintained. Sidewalks will be installed throughout the site and along NW Sunrise Drive and NW 6th Street. Public Utilities are available to the site and storm water management will be provided with a retention basin on the north side of the site. A total of 2.3 acres of parkland dedication is required and the applicant has proposed a fee in lieu of land dedication. All parking, landscape, open space, and elevation requirements have been met at this time. Staff would recommend approval of the site plan for Converge NW Plat 1 subject to any remaining staff comments and review of the legal documents.  Commissioner Koshy questioned how many parking structures were on site. Mr. Kass advised 2 double sided structures in the middle of the site and two single sided structures on the west side of the site.  Commissioner Broderick verified that an owners association would be established. Mr. Kass advised that was correct. Commissioner Hoifeldt moved to approve the Site Plan for Converge NW Plat 1 subject to any remaining staff comments and review of the legal documents. Commissioner Gerlitz seconded the motion. Ayes: Broderick, Hoifeldt, Koshy, Ward, and Gerlitz. Nays: none. Motion Carried. STAFF REVIEW AND COMMENT: Staff recommends approval of the site plan subject to remaining staff comments. RECOMMENDATION: Approve the resolution subject to remaining staff comments. ATTACHMENTS: I. Proposed Resolution II. Staff Report III. Site Plan & Elevations PREPARED BY: Andy Kass, Community Development Director REVIEWED BY: THE CITY OF WAUKEE, IOWA RESOLUTION 2022- APPROVING THE SITE PLAN FOR CONVERGE NW PLAT 1 (350 NW 6TH STREET) IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Site Plan for Converge NW Plat 1, subject to remaining staff comments on January 11, 2022; AND, WHEREAS, the Site Plan for Converge NW Plat 1 is in general conformance with §160 – Site and Building Development Standards Ordinance of the Waukee Municipal Code; AND, WHEREAS, the Site Plan for Converge NW Plat 1 is in general conformance with §161 – Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND, NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 7th day of February, 2022 that the Site Plan for Converge NW Plat 1 is approved subject to remaining staff comments. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Anna Bergman Pierce R. Charles Bottenberg Chris Crone Larry R. Lyon Ben Sinclair PLANNING AND ZONING COMMISSION STAFF REPORT PROJECT: Converge NW Plat 1 – Preliminary Plat, Final Plat, & Site Plan PREPARED BY: Andy Kass, AICP, Community Development Director REPORT DATE: January 7, 2022 MEETING DATE: January 11, 2022 GENERAL INFORMATION Applicant: Hubbell Development Services Owner: Waukee Crossing, LLC Owner’s Representative: Ryan Hardisty, P.E. – Civil Design Advantage Request: The applicant is requesting approval of a preliminary plat, final plat, and site plan for a multi- family residential development. Location and Size: Property is generally located south of NW Sunrise Drive and east of NW 10th Street, containing approximately 15-acres. AREA MAP ABOVE: Aerial of subject property (outlined in BLUE) in relation to the surrounding area. January 7, 2022 2 of 3 LAND USES AND ZONING Location Existing Land Use Comprehensive Plan Current Zoning Property in Question Vacant - Undeveloped Single Family Residential & Medium Density Residential R-3 (Multi-Family Residential District) North Waukee Northwest High School Institutional A-1 (Agricultural District) South Industrial Single Family Residential & Medium Density Residential R-3 (Multi-Family Residential District) East Vacant – Undeveloped & Townhomes Single Family Residential & Medium Density Residential R-2 (One & Two Family Residential District) West Vacant Single Family Residential & Medium Density Residential C-1 (Community and Highway Service Commercial District) HISTORY The subject property is located south of Waukee Northwest High School and east of NW 10th Street. The property is approximately 15-acres in area and was the subject of a rezoning in summer 2021. The lot was originally platted as Outlot Y of Waukee Crossing Plat 2. PROJECT DESCRIPTION The project involves the construction of three (3) apartment buildings, eight (8) townhome buildings, and one (1) clubhouse. The apartment buildings are proposed to be three stories in height and will contain 60 units per building. Apartment unit square footages will range from 673 square feet to 1,383 square feet. Four (4) separate garage buildings are sown on the site plan that will be available to the apartment residents. The townhome buildings will be a mix of single and two-story units and will have three (3) to five (5) units per building. Square footages of the units will range from 1,634 square feet to 2,028 square feet. All townhome units will feature a two-car garage. All apartment and townhome units are intended to be rental units. The clubhouse shown on the site plan is 3,154 square feet in area and will feature a communal space and a pool for the use by the complex residents. All proposed buildings comply with the bulk regulations of the R-3 zoning district. Trash service for the apartments will be provided by two separate trash enclosures located on the site. Trash service to the townhome units will be provided by individual receptacles for each unit. Table 1: Bulk Regulations for the R-3 District Category R-3 (minimum) Front Yard Setback 30 feet (perimeter) Rear Yard Setback 30 feet Side Yard Setback 10 feet Maximum Density 4 units/acre ACCESS AND PARKING Access to the property is provided from NW 6th Street. The developer of Waukee Crossing Plat 2 is in the process of installing the plat improvements for Waukee Crossing Plat 2 which will include the extension of NW 6th Street. NW Converge Circle will provide access to the townhome units. All streets and access dries internal to the site will be privately owned and maintained. January 7, 2022 3 of 3 Sidewalks will be provided throughout the site. In addition, sidewalks will be installed along NW Sunrise Drive and NW 6th Street. A total of 324 parking spaces are required for the apartment units and the site plan identifies 324 parking spaces. For the townhome units 73 parking spaces are required and the site plan identifies a total of 73 parking spaces. UTILITIES The developer of Waukee Crossing Plat 2 is in the process of installing the plat improvements for Waukee Crossing Plat 2 which will include the extension sanitary sewer, water main, and storm sewer throughout the plat. Connections to the plat utilities will be made and extended throughout the site. The applicant will make a short extension of public sanitary sewer to serve the commercial property to the west. Stormwater management will be provided in a retention basin on the north side of the site. LANDSCAPING & OPEN SPACE The R-3 zoning district requires 20% open space. The site plan shows that 49.2% open space is being provided on the site. Landscape buffers are required on the east and north sides of the site. PARKLAND DEDICATION A total of 2.3-acres of parkland dedication is required. The applicant has proposed to satisfy this requirement with a fee in lieu of land dedication. ELEVATIONS Elevations of the available units and clubhouse have been provided by the applicant. Proposed materials include hardboard siding, vinyl siding, asphalt shingles, and brick or stone. LOTS One lot is shown on the preliminary plat and final plat. Lot 1 is 15.00-acres in area. Lot 1 complies will all requirements of the R-3 zoning district. STAFF RECOMMENDATION The site plan is in general conformance with the Zoning Ordinance, Subdivision Ordinance, Site Plan Ordinance, and Comprehensive Plan. Staff recommends approval of the preliminary plat, final plat, and site plan subject to remaining staff comments and review of the legal documents. CONVERGE NW PLAT 13405 SE CROSSROADS DR. SUITE G, GRIMES, IOWA 50111PH: (515) 369-4400CIVIL DESIGN ADVANTAGEUTILITY WARNINGEXISTING/ PROPOSED USEPROJECT SITE ADDRESSZONINGINDEX OF SHEETSVICINITY MAPGENERAL LEGENDLEGAL DESCRIPTIONDATE OF SURVEYBENCHMARKSCONVERGE NW PLAT 1SITE PLAN FOR:WAUKEE, IOWAHICKMAN ROADSITEPRELIMINARYNOT FOR CONSTRUCTIONllllllwww.iowaonecall.com1-800-292-8989ONE CALLIOWAONE CALLKnow what'sbefore you dig.below.CallWAUKEE, IOWAN. 10TH ST.NW SUNRISE DR.DEVELOPMENT SUMMARYPARKING REQUIREMENTSSUBMITTAL DATESARCHITECTSURVEYOROWNERENGINEERAPPLICANT NW SUNRISE DRIVENW 6TH STREETN10°53'15"W 44.61'N53°18'32"W 99.85'S84°16'09"W 231.73'Δ=6°05'16"L=53.23'R=501.00'CH=53.21'CHB=S87°18'46"WN89°38'37"W 467.58'S00°02'18"W 719.95'S89°38'37"E 1043.47'N32°28'53"W 140.80'Δ=29°55'10"L=284.59'R=545.00'CH=281.37'CHB=N17°31'22"WN02°33'51"W 5.00'N05°06'22"W 92.71'Δ=11°29'30"L=116.33'R=580.00'CH=116.13'CHB=N10°51'05"WN16°35'49"W 18.98'Δ=5°42'35"L=29.90'R=300.00'CH=29.88'CHB=N13°44'32"WWAUKEE CROSSINGSEC/TWP/RNG: 28-79-26CIVIL DESIGN ADVANTAGE2104.247CONVERGE NW PLAT 1 ENGINEER:TECH: REVISIONS DATE WAUKEE, IOWA23 FIRST SUBMITTAL 10/12/2021 PHONE: (515) 369-4400 4121 NW URBANDALE DRIVE URBANDALE, IOWA 50322 SECOND SUBMITTAL 11/02/2021 THIRD SUBMITTAL 11/19/2021 FOURTH SUBMITTAL 12/15/2021 FIFTH SUBMITTAL 01/07/2022 SIXTH SUBMITTAL 02/02/2022 EXISTING SITE2 N10°53'15"W 44.61'N53°18'32"W 99.85'S84°16'09"W 231.73'Δ=6°05'16"L=53.23'R=501.00'CH=53.21'CHB=S87°18'46"WN89°38'37"W 467.58'S00°02'18"W 719.95'S89°38'37"E 1043.47'N32°28'53"W 140.80'Δ=29°55'10"L=284.59'R=545.00'CH=281.37'CHB=N17°31'22"WN02°33'51"W 5.00'N05°06'22"W 92.71'Δ=11°29'30"L=116.33'R=580.00'CH=116.13'CHB=N10°51'05"WN16°35'49"W 18.98'NW SUNRISE DRIVENW 6TH STREETΔ=5°42'35"L=29.90'R=300.00'CH=29.88'CHB=N13°44'32"WNW CONVERGE CIRCLENW CONVERGE CIRCLE NW CONVERGE LANELOT 1:350 NW 6TH STREET15.00 ACRESCIVIL DESIGN ADVANTAGE2104.247CONVERGE NW PLAT 1 ENGINEER:TECH: REVISIONS DATE WAUKEE, IOWA23 FIRST SUBMITTAL 10/12/2021 PHONE: (515) 369-4400 4121 NW URBANDALE DRIVE URBANDALE, IOWA 50322 SECOND SUBMITTAL 11/02/2021 THIRD SUBMITTAL 11/19/2021 FOURTH SUBMITTAL 12/15/2021 FIFTH SUBMITTAL 01/07/2022 SIXTH SUBMITTAL 02/02/2022 DIMENSION PLAN OVERALL GENERAL NOTESPAVEMENT THICKNESS3BUILDING INFORMATION NW SUNRISE DRIVECIVIL DESIGN ADVANTAGE2104.247CONVERGE NW PLAT 1 ENGINEER:TECH: REVISIONS DATE WAUKEE, IOWA23 FIRST SUBMITTAL 10/12/2021 PHONE: (515) 369-4400 4121 NW URBANDALE DRIVE URBANDALE, IOWA 50322 SECOND SUBMITTAL 11/02/2021 THIRD SUBMITTAL 11/19/2021 FOURTH SUBMITTAL 12/15/2021 FIFTH SUBMITTAL 01/07/2022 SIXTH SUBMITTAL 02/02/2022 DIMENSION PLAN4 NW 6TH STREETNW SUNRISE DRIVECIVIL DESIGN ADVANTAGE2104.247CONVERGE NW PLAT 1 ENGINEER:TECH: REVISIONS DATE WAUKEE, IOWA23 FIRST SUBMITTAL 10/12/2021 PHONE: (515) 369-4400 4121 NW URBANDALE DRIVE URBANDALE, IOWA 50322 SECOND SUBMITTAL 11/02/2021 THIRD SUBMITTAL 11/19/2021 FOURTH SUBMITTAL 12/15/2021 FIFTH SUBMITTAL 01/07/2022 SIXTH SUBMITTAL 02/02/2022 DIMENSION PLAN5 NW CONVERGE CIRCLENW CONVERGE LANECIVIL DESIGN ADVANTAGE2104.247CONVERGE NW PLAT 1 ENGINEER:TECH: REVISIONS DATE WAUKEE, IOWA23 FIRST SUBMITTAL 10/12/2021 PHONE: (515) 369-4400 4121 NW URBANDALE DRIVE URBANDALE, IOWA 50322 SECOND SUBMITTAL 11/02/2021 THIRD SUBMITTAL 11/19/2021 FOURTH SUBMITTAL 12/15/2021 FIFTH SUBMITTAL 01/07/2022 SIXTH SUBMITTAL 02/02/2022 DIMENSION PLAN6 NW 6TH STREETNW CONVERGE CIRCLENW CONVERGE CIRCLENW CONVERGE LANECIVIL DESIGN ADVANTAGE2104.247CONVERGE NW PLAT 1 ENGINEER:TECH: REVISIONS DATE WAUKEE, IOWA23 FIRST SUBMITTAL 10/12/2021 PHONE: (515) 369-4400 4121 NW URBANDALE DRIVE URBANDALE, IOWA 50322 SECOND SUBMITTAL 11/02/2021 THIRD SUBMITTAL 11/19/2021 FOURTH SUBMITTAL 12/15/2021 FIFTH SUBMITTAL 01/07/2022 SIXTH SUBMITTAL 02/02/2022 DIMENSION PLAN7 NW SUNRISE DRIVENW 6TH STREETNW CONVERGE CIRCLENW CONVERGE CIRCLE NW CONVERGE LANECIVIL DESIGN ADVANTAGE2104.247CONVERGE NW PLAT 1 ENGINEER:TECH: REVISIONS DATE WAUKEE, IOWA23 FIRST SUBMITTAL 10/12/2021 PHONE: (515) 369-4400 4121 NW URBANDALE DRIVE URBANDALE, IOWA 50322 SECOND SUBMITTAL 11/02/2021 THIRD SUBMITTAL 11/19/2021 FOURTH SUBMITTAL 12/15/2021 FIFTH SUBMITTAL 01/07/2022 SIXTH SUBMITTAL 02/02/2022 GRADING PLAN OVERALL GRADING NOTES8 F.F.E.=1022.81F.F.E.=1023.40G.F.E.=1023.39DETENTIONBASINCIVIL DESIGN ADVANTAGE2104.247CONVERGE NW PLAT 1 ENGINEER:TECH: REVISIONS DATE WAUKEE, IOWA23 FIRST SUBMITTAL 10/12/2021 PHONE: (515) 369-4400 4121 NW URBANDALE DRIVE URBANDALE, IOWA 50322 SECOND SUBMITTAL 11/02/2021 THIRD SUBMITTAL 11/19/2021 FOURTH SUBMITTAL 12/15/2021 FIFTH SUBMITTAL 01/07/2022 SIXTH SUBMITTAL 02/02/2022 GRADING PLAN9 F.F.E.=1023.22F.F.E.=1023.60F.F.E.=1024.05DETENTIONBASINCIVIL DESIGN ADVANTAGE2104.247CONVERGE NW PLAT 1 ENGINEER:TECH: REVISIONS DATE WAUKEE, IOWA23 FIRST SUBMITTAL 10/12/2021 PHONE: (515) 369-4400 4121 NW URBANDALE DRIVE URBANDALE, IOWA 50322 SECOND SUBMITTAL 11/02/2021 THIRD SUBMITTAL 11/19/2021 FOURTH SUBMITTAL 12/15/2021 FIFTH SUBMITTAL 01/07/2022 SIXTH SUBMITTAL 02/02/2022 GRADING PLAN10 F.F.E.=1023.46F.F.E.=1024.88F.F.E.=1024.62F.F.E.=1024.95G.F.E.=1023.70G.F.E.=1023.39CIVIL DESIGN ADVANTAGE2104.247CONVERGE NW PLAT 1 ENGINEER:TECH: REVISIONS DATE WAUKEE, IOWA23 FIRST SUBMITTAL 10/12/2021 PHONE: (515) 369-4400 4121 NW URBANDALE DRIVE URBANDALE, IOWA 50322 SECOND SUBMITTAL 11/02/2021 THIRD SUBMITTAL 11/19/2021 FOURTH SUBMITTAL 12/15/2021 FIFTH SUBMITTAL 01/07/2022 SIXTH SUBMITTAL 02/02/2022 GRADING PLAN11 F.F.E.=1024.05F.F.E.=1023.10F.F.E.=1023.00F.F.E.=1024.62F.F.E.=1022.80F.F.E.=1022.65F.F.E.=1023.40CIVIL DESIGN ADVANTAGE2104.247CONVERGE NW PLAT 1 ENGINEER:TECH: REVISIONS DATE WAUKEE, IOWA23 FIRST SUBMITTAL 10/12/2021 PHONE: (515) 369-4400 4121 NW URBANDALE DRIVE URBANDALE, IOWA 50322 SECOND SUBMITTAL 11/02/2021 THIRD SUBMITTAL 11/19/2021 FOURTH SUBMITTAL 12/15/2021 FIFTH SUBMITTAL 01/07/2022 SIXTH SUBMITTAL 02/02/2022 GRADING PLAN12 F.F.E.=1023.00F.F.E.=1023.46F.F.E.=1024.88F.F.E.=1024.62F.F.E.=1024.95G.F.E.=1023.70CIVIL DESIGN ADVANTAGE2104.247CONVERGE NW PLAT 1 ENGINEER:TECH: REVISIONS DATE WAUKEE, IOWA23 FIRST SUBMITTAL 10/12/2021 PHONE: (515) 369-4400 4121 NW URBANDALE DRIVE URBANDALE, IOWA 50322 SECOND SUBMITTAL 11/02/2021 THIRD SUBMITTAL 11/19/2021 FOURTH SUBMITTAL 12/15/2021 FIFTH SUBMITTAL 01/07/2022 SIXTH SUBMITTAL 02/02/2022 GRADING PLAN13 CIVIL DESIGN ADVANTAGE2104.247CONVERGE NW PLAT 1 ENGINEER:TECH: REVISIONS DATE WAUKEE, IOWA23 FIRST SUBMITTAL 10/12/2021 PHONE: (515) 369-4400 4121 NW URBANDALE DRIVE URBANDALE, IOWA 50322 SECOND SUBMITTAL 11/02/2021 THIRD SUBMITTAL 11/19/2021 FOURTH SUBMITTAL 12/15/2021 FIFTH SUBMITTAL 01/07/2022 SIXTH SUBMITTAL 02/02/2022 GRADING PLAN - SIDEWALK RAMP DETAILS14 DETAIL 'A'DETAIL 'B'DETAIL 'C'DETAIL 'D'DETAIL 'E'DETAIL 'F'DETAIL 'G'DETAIL 'H'DETAIL 'I'DETAIL 'J'DETAIL 'K'DETAIL 'L'DETAIL 'M' Rlllllll lllllllllllllllll lllllllllllllllll llllllllllllllllllllllllllllllllllllllllllllllllllll lllllllllllllllll lllllllllllllllll lllllllllllllllll llllllllllllllllllllllllllllllllll llllllllll llllllllllllllll lllllllllllllllll llllllllllllllll llllllllllllllll lllllllllllllllll l l l l l l l llllllllllll l l l l l l l lll llll llll llll llll llll llll llll llll llll llll llll llll llll llll llll ll llllllllllllllNW SUNRISE DRIVENW 6TH STREETDA #117.15 ACRTSB #llllSWPPP LEGENDVICINITY MAPDISCHARGE POINT SUMMARYSTABILIZATION QUANTITIESCIVIL DESIGN ADVANTAGE2104.247CONVERGE NW PLAT 1 ENGINEER:TECH: REVISIONS DATE WAUKEE, IOWA PHONE: (515) 369-4400 4121 NW URBANDALE DRIVE URBANDALE, IOWA 50322 EROSION AND SEDIMENT CONTROL PLAN2315NOTES:HICKMAN ROADSITEWAUKEE, IOWAN. 10TH ST.NW SUNRISE DR. NW SUNRISE DRIVENW 6TH STREETNW CONVERGE CIRCLENW CONVERGE CIRCLE NW CONVERGE LANECIVIL DESIGN ADVANTAGE2104.247CONVERGE NW PLAT 1 ENGINEER:TECH: REVISIONS DATE WAUKEE, IOWA23 FIRST SUBMITTAL 10/12/2021 PHONE: (515) 369-4400 4121 NW URBANDALE DRIVE URBANDALE, IOWA 50322 SECOND SUBMITTAL 11/02/2021 THIRD SUBMITTAL 11/19/2021 FOURTH SUBMITTAL 12/15/2021 FIFTH SUBMITTAL 01/07/2022 SIXTH SUBMITTAL 02/02/2022 UTILITY PLAN OVERALL UTILITY NOTES16 CIVIL DESIGN ADVANTAGE2104.247CONVERGE NW PLAT 1 ENGINEER:TECH: REVISIONS DATE WAUKEE, IOWA23 FIRST SUBMITTAL 10/12/2021 PHONE: (515) 369-4400 4121 NW URBANDALE DRIVE URBANDALE, IOWA 50322 SECOND SUBMITTAL 11/02/2021 THIRD SUBMITTAL 11/19/2021 FOURTH SUBMITTAL 12/15/2021 FIFTH SUBMITTAL 01/07/2022 SIXTH SUBMITTAL 02/02/2022 UTILITY PLAN17 CIVIL DESIGN ADVANTAGE2104.247CONVERGE NW PLAT 1 ENGINEER:TECH: REVISIONS DATE WAUKEE, IOWA23 FIRST SUBMITTAL 10/12/2021 PHONE: (515) 369-4400 4121 NW URBANDALE DRIVE URBANDALE, IOWA 50322 SECOND SUBMITTAL 11/02/2021 THIRD SUBMITTAL 11/19/2021 FOURTH SUBMITTAL 12/15/2021 FIFTH SUBMITTAL 01/07/2022 SIXTH SUBMITTAL 02/02/2022 UTILITY PLAN18 CIVIL DESIGN ADVANTAGE2104.247CONVERGE NW PLAT 1 ENGINEER:TECH: REVISIONS DATE WAUKEE, IOWA23 FIRST SUBMITTAL 10/12/2021 PHONE: (515) 369-4400 4121 NW URBANDALE DRIVE URBANDALE, IOWA 50322 SECOND SUBMITTAL 11/02/2021 THIRD SUBMITTAL 11/19/2021 FOURTH SUBMITTAL 12/15/2021 FIFTH SUBMITTAL 01/07/2022 SIXTH SUBMITTAL 02/02/2022 UTILITY PLAN19 CIVIL DESIGN ADVANTAGE2104.247CONVERGE NW PLAT 1 ENGINEER:TECH: REVISIONS DATE WAUKEE, IOWA23 FIRST SUBMITTAL 10/12/2021 PHONE: (515) 369-4400 4121 NW URBANDALE DRIVE URBANDALE, IOWA 50322 SECOND SUBMITTAL 11/02/2021 THIRD SUBMITTAL 11/19/2021 FOURTH SUBMITTAL 12/15/2021 FIFTH SUBMITTAL 01/07/2022 SIXTH SUBMITTAL 02/02/2022 UTILITY PLAN20 CIVIL DESIGN ADVANTAGE2104.247CONVERGE NW PLAT 1 ENGINEER:TECH: REVISIONS DATE WAUKEE, IOWA23 FIRST SUBMITTAL 10/12/2021 PHONE: (515) 369-4400 4121 NW URBANDALE DRIVE URBANDALE, IOWA 50322 SECOND SUBMITTAL 11/02/2021 THIRD SUBMITTAL 11/19/2021 FOURTH SUBMITTAL 12/15/2021 FIFTH SUBMITTAL 01/07/2022 SIXTH SUBMITTAL 02/02/2022 DETAILS °WATER SERVICE CONNECTIONCITY OF WAUKEEUTILITY SERVICE LOCATIONSROCK APRON FOR PIPE OUTLET6" STANDARD CURB12" SUBGRADE PREPARATIONSIDEWALKTRAILCLASS 'A' INTEGRAL CURB213" INTEGRAL ROLLED CURB6" TO 3" CURB TRANSITION CIVIL DESIGN ADVANTAGE2104.247CONVERGE NW PLAT 1 ENGINEER:TECH: REVISIONS DATE WAUKEE, IOWA23 FIRST SUBMITTAL 10/12/2021 PHONE: (515) 369-4400 4121 NW URBANDALE DRIVE URBANDALE, IOWA 50322 SECOND SUBMITTAL 11/02/2021 THIRD SUBMITTAL 11/19/2021 FOURTH SUBMITTAL 12/15/2021 FIFTH SUBMITTAL 01/07/2022 SIXTH SUBMITTAL 02/02/2022 DETAILS°SANITARY SEWER SERVICE RISERHYDRANT ASSEMBLY DETAILSECTION TYPICAL - WET BOTTOM POND22CLUBHOUSE FENCE6' X 6' SW-513 INTAKE (ST-2) PLANT SCHEDULE LANDSCAPE PLANLEGEND LANDSCAPE NOTESOPEN SPACE REQUIREMENTSPARKING LANDSCAPE REQUIREMENTSCIVIL DESIGN ADVANTAGE2104.247CONVERGE NW PLAT 1 ENGINEER:TECH: REVISIONS DATE WAUKEE, IOWA23 FIRST SUBMITTAL 10/12/2021 PHONE: (515) 369-4400 4121 NW URBANDALE DRIVE URBANDALE, IOWA 50322 SECOND SUBMITTAL 11/02/2021 THIRD SUBMITTAL 11/19/2021 FOURTH SUBMITTAL 12/15/2021 FIFTH SUBMITTAL 01/07/2022 SIXTH SUBMITTAL 02/02/2022 23LANDSCAPE BUFFER FIRST FLOOR 100' - 0" THIRD FLOOR 122' - 4 5/8" TRUSS BEARING 131' - 4 7/8" SECOND FLOOR 111' - 2 3/4" FAS-1TRMFAS-2FAS-2 RF FCB-1 STN FCP-1FCP-1 BRK STN FCB-1 BRK STN FCB-1 FCP-1 FCP-2 FCP-1 BRK FCP-2 FCP-2 FCP-2 FCP-2 FIRST FLOOR 100' - 0" THIRD FLOOR 122' - 4 5/8" TRUSS BEARING 131' - 4 7/8" SECOND FLOOR 111' - 2 3/4" FCB-1 RF FCB-1FCB-1 STN STN STN BRK FCP-1FCP-1 BRK FCP-2FCP-2 FCP-2FCP-1FCP-2 FCP-1 BRK FAS-1 TRM FAS-2 FAS-2 FCP-2 FIRST FLOOR 100' - 0" RF VNLTRM FAS-2 TRM FIRST FLOOR 100' - 0" GUT FAS-2 TRM RF VNL SAA JOB #: This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C. 24"x36" SHEET (FULL SIZE) -SCALE IS AS NOTED. 12"x18" SHEET (HALF SIZE) -SCALE IS ONE-HALF OF WHAT IS NOTED OTHER SHEET SIZES NOT TO SCALE 21113 WAUKEE CROSSING APARTMENTS WAUKEE, IA 10/12/21 SCALE:1/8" = 1'-0"1 TYPICAL BACK ELEVATION BACK ELEVATION: 7,795 SF EXCLUDING GLAZING (TOTAL = 10,429 SF) STONE/BRICK = 2738 SF (35%) FIBER CEMENT PANEL & BOARD: 5057 SF EXTERIOR MATERIAL LEGEND MAT. LABEL MATERIAL DESCRIPTION BRK MERIDIAN BRICK, THIN BRICK, COLOR - AMARO, NATURAL MORTAR DS PREFINISHED METAL DOWNSPOUT, COLOR - WHITE FAS-1 HARDIE FASCIA BOARD, SMOOTH, COLOR - ARCTIC WHITE FAS-2 PREFINISHED METAL FASCIA, COLOR - WHITE FCB-1 FIBER CEMENT LAP SIDING, SMOOTH, 6" REVEAL, COLOR - ARCTIC WHITE FCP-1 FIBER CEMENT PANEL SMOOTH SIDING, COLOR - COBBLESTONE FCP-2 FIBER CEMENT PANEL SMOOTH SIDING, COLOR - AGED PEWTER GUT PREFINISHED SEAMLESS GUTTERS, COLOR - WHITE RF ARCHITECTURAL ASPHALT ROOFING SHINGLES, COLOR - CHARCOAL SF T.B. ALUMINUM STOREFRONT FRAMING: CLEAR ANODIZED FINISH STN CENTURION STONE, COASTAL OHIO LIMESTONE TRM 5/4 HARDIE TRIM BOARD, SMOOTH, COLORPLUS, COLOR - ARCTIC WHITE VIS INSULATED VISION GLASS: CLEAR W/ LOW E COATING IN VINYL RESIDENTIALSTYLE WINDOw VNL VINYL LAP SIDING, SMOOTH, 6" REVEAL, COLOR - DARK GRAY EXTERIOR MATERIAL CALCULATIONS: SCALE:1/8" = 1'-0"2 GARAGE FRONT (& REAR AT LOCATIONS) ELEVATION TYPICAL SCALE:1/8" = 1'-0"3 GARAGE SIDE ELEVATION TYPICAL Simonson & Associates Architects LLC and their consultants has completed these design documents to the level of detail requested by our client. The level of detail may range from schematic design document(s) mainly conveying programmatic information to fully detailed documents and specifications. However, the clients intent and expectations are that these documents be used as the basis for design for an complete all-inclusive project based upon industry standards & manufacturer recommendations for all disciplines & materials. It should also satisfy all authorities having jurisdiction requirements. IMPORTANT DESIGN SCOPE NOTE:CLIENT Hubbell Realty Company - Managing Member 6900 Westown Parkway West Des Moines, IA 50266 (515) 243-3228 (515) 280-2000 Fax contact: Matt Weller e-mail: matt.weller@hubbellrealty.com phone: (515) 280-2041 ARCHITECT Simonson & Associates Architects L.L.C. 1717 Ingersoll Avenue, Suite 117 Des Moines, IA 50309 (515) 440-5626 (515) 440-0964 Fax contact: Stephanie Poole e-mail: spoole@simonsonassoc.com CIVIL ENGINEER Civil Design Advantage 3405 SE Crossroads Dr., Suite G Grimes, IA 50111 (515) 369-4400 (515) 369-4410 Fax contact: Ryan Hardisty e-mail: RyanH@cda-eng.com STRUCTURAL ENGINEER Raker Rhodes Engineering, LLC 4717 Grand Ave. Des Moines, IA 50312 (515) 277-0275 (515) 277-0276 Fax contact: John Rhodes e-mail: jrhodes@rakerrhodes.com contact: Chris Harre e-mail: charre@rakerrhodes.com GENERAL CONTRACTOR Hubbell Construction Services 6900 Westown Parkway West Des Moines, IA 50266 (515) 243-3228 (515) 280-2000 Fax contact: Colleen Ladd e-mail: colleen.ladd@hubbellrealty.com phone: (407) 489-3626 City of Waukee Development Services 230 W. Hickman Road Waukee, IA 50263 515) 987-4522 contact: Keith Rash e-mail: krash@waukee.org phone: (515) 978-9533 cell JURISDICTION 1. THESE DOCUMENTS & THE DESIGN THEY REPRESENT ARE THE PROPERTY OF SIMONSON & ASSOCIATES ARCHITECTS LLC. NO CHANGES TO THESE DOCUMENTS EITHER IN WHOLE OR IN PART MAY BE MADE IN ANY WAY WITHOUT THEIR PRIOR KNOWLEDGE & WRITTEN CONSENT. 2. REFER TO ADDITIONAL NOTES AND LEGENDS ON ALL OTHER DOCUMENTS. 3. REFER TO CIVIL, GEOTECHNICAL, ENVIRONMENTAL, STRUCTURAL, FIRE SUPPRESSION, PLUMBING, MECHANICAL, ELECTRICAL, COMMUNICATIONS, ELECTRONIC SAFETY & SECURITY DOCUMENTS FOR ADDITIONAL INFORMATION OR REQUIREMENTS. REFERENCE TO OTHER DISCIPLINES IS CONCEPTUAL FOR PURPOSES OF COORDINATION WITH ARCHITECTURAL DESIGN ONLY. 4. BEFORE COMMENCEMENT OF ANY WORK, CONTRACTOR SHALL GIVE ALL NOTICES AND OBTAIN ALL PERMITS. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES, LAWS, ORDINANCES, RULES, REGULATIONS, REQUIREMENTS OF GOVERNING AGENCIES AND AUTHORITIES, HAZARDOUS MATERIAL APPLICATION AND DISPOSAL REQUIREMENTS, ETC. 5. THE ADA OR ADAAG IS A CIVIL RIGHTS ACT AND IS SUBJECT TO LEGAL INTERPRETATION THROUGH THE JUDICIAL PROCESS. REASONABLE CARE WAS EXERCISED IN INTERPRETING THE GUIDELINES AND ALL GUIDELINES MAY NOT BE INDICATED ON THESE PLANS: HOWEVER, FAILURE TO IDENTIFY A GUIDELINE DOES NOT GIVE THIS CONTRACTOR THE RIGHT TO VIOLATE THEM. THE CONTRACTOR MUST COMPLY WITH ALL GUIDELINES AS REQUIRED BY THE ADAAG. 6. THESE DRAWINGS REPRESENT THE COMPLETED PROJECT, AT TIME OF SUBSTANTIAL COMPLETION. THE INTENT OF THE DRAWINGS IS TO INCLUDE ALL ITEMS NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. UNLESS OTHERWISE NOTED, THEY DO NOT REPRESENT THE MEANS AND METHODS OF CONSTRUCTION. SEQUENCING AND MEANS AND METHODS OF CONSTRUCTION SHALL BE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 7. THESE DRAWINGS DO NOT CONTAIN INFORMATION WITH REGARD TO CONSTRUCTION SAFETY PROCEDURES. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL CONSTRUCTION SAFETY AND SHALL PERFORM ALL WORK IN ACCORDANCE WITH GOVERNING AUTHORITIES CONSTRUCTION SAFETY GUIDELINES. 8. PROVIDE COMPLETE IN PLACE ALL LABOR, TRANSPORTATION, MATERIAL, TAXES, FEES, PERMITS, LICENSES, INSURANCE, UTILITIES, INSPECTIONS, EQUIPMENT, MACHINERY, SUPERVISION, AND OTHER ITEMS NECESSARY TO COMPLETE THE WORK IN STRICT COMPLIANCE WITH THE PLANS, DOCUMENTS AND SPECIFICATIONS PREPARED BY THE ARCHITECT AND APPROVED BY THE OWNER. 9. VERIFY EXISTING CONDITIONS PRIOR TO FABRICATION AND PRIOR TO PROCEEDING WITH THE WORK, AND NOTIFY THE ARCHITECT IMMEDIATELY OF SIGNIFICANT DISCREPANCIES WHICH MAY IMPACT AESTHETICS, DURABILITY, COST AND/OR SCHEDULES. 10. DO NOT SCALE DRAWINGS IN ORDER TO DETERMINE INTENDED LAYOUT OR DIMENSIONS. IF DIMENSIONS ARE IN QUESTION THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION BEFORE CONTINUING WITH WORK. DRAWINGS ARE INTENDED ONLY AS A GRAPHICALLY CORRECT REPRESENTATION OF WORK TO BE ACCOMPLISHED. 11. THE CONTRACTOR SHALL PROTECT ALL EXISTING ENTITIES. REMOVE, REPLACE OR REPAIR MATERIALS, FACILITIES AND SERVICES DAMAGED DURING THE COURSE OF CONSTRUCTION TO THE SATISFACTION OF THE OWNER AND GOVERNING AUTHORITY. 12. ALL WORK SHALL BE OF GOOD QUALITY AND ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND FREE FROM DEFECTS FOR A PERIOD OF 1 YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION OF WORK. ANY EXTENDED WARRANTIES OBTAINED FROM SUPPLIERS OR SUBCONTRACTORS SHALL BE FORWARDED TO THE OWNER. 13. ALL REQUIREMENTS NOT FOLLOWED, INCLUDING SUBSTITUTIONS NOT PROPERLY APPROVED AND AUTHORIZED, IN WRITING, MAY BE CONSIDERED DEFECTIVE. 14. FAILURE TO IDENTIFY A STANDARD, RECOMMENDATION &/OR REQUIREMENT DOES NOT GIVE ANYONE THE RIGHT TO VIOLATE ANY CODE & GOVERNING AUTHORITY REQUIREMENTS, MINIMUM QUALITY OR QUANTITY REQUIRED, ASTM & OTHER INDUSTRY STANDARDS, MANUFACTURER RECOMMENDATIONS & REQUIREMENTS, ETC. 15. COMPLY WITH ALL WEATHER-RELATED CONSTRUCTION REQUIREMENTS. DO NOT BUILD WITH OR ON FROZEN, SATURATED, CONTAMINATED OR INAPPROPRIATE SUBSTRATES OR CONDITIONS. BUILD OVER DRY COMPACTED APPROVED GRADE WITH APPROVED APPROPRIATE MATERIALS. 16. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM AND OFF ALL BUILDINGS WITHOUT PONDING OR WATER ADJACENT TO OR ON BUILDINGS OR PAVEMENTS. 17. BY SUBMITTING SHOP DRAWINGS, PRODUCT DATA AND SAMPLES, THE GENERAL CONTRACTOR AND SUB- CONTRACTOR HAS VERIFIED AND APPROVED THE INFORMATION CONTAINED WITHIN. THE GENERAL CONTRACTOR'S REVIEW AND APPROVAL SHALL BE SHOWN ON EACH SUBMITTAL PRIOR TO THE SUBMISSION TO THE ARCHITECT. 18. THE GENERAL CONTRACTOR SHALL FORWARD TO SUBCONTRACTORS & SUPPLIERS, FULL SETS OF BIDDING &/OR CONSTRUCTION DOCUMENTS, INCLUDING, BUT NOT LIMITED TO, DRAWINGS, SPECIFICATIONS, ADDENDA, CLARIFICATIONS, BID FORMS, & ALL OTHER DOCUMENTATION ISSUED BY ARCHITECT & ARCHITECT'S CONSULTANTS TOWARD CONVEYING A COMPLETE & TIMELY PROJECT. GENERAL NOTES: FIRE SUPPRESSION (Refer to these design documents under separate cover.) ELECTRONIC SAFETY & SECURITY (Refer to these design documents under separate cov er.) CIVIL - LANDSCAPING (Refer to these design documents under separate cover.) ENVIRONMENTAL (Refer to these condition documents under separate cover) PLUMBING (Refer to these design documents under separate cov er.) SPECIFICATION MANUAL Not Provided - All Specification Notes included on drawings. ENERGY Refer to Perscriptive Code on Sheet G-101. COMMUNICATIONS (Refer to these design documents under separate cov er.) HEATING, VENTILATING, & AIR CONDITIONING (Refer to these design documents under separate cov er.) ELECTRICAL (Refer to these design documents under separate cov er.) DOCUMENTS BY OTHERS GEOTECHNICAL INVESTIGATIONS (Refer to these condition documents under separate cover)This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.Sheet No. Sheet Title Job No.Proj. Mgr.12/3/2021 5:52:03 AMJ:\2021\21113 Waukee Crossing Multi-Family - Hubbell\CAD-Arch\21113 Converge NW, Waukee, IA_60 Unit Apartment.rvt21113 SP COVER SHEET G-000CONVERGE NWAPARTMENTSWAUKEE, IAI hereby certify that the portion of this technical submission described below was prepared by me or under my direct supervision and responsible charge. I am a duly licensed architect under the laws of the State of Iowa. Registration Expires Pages or Sheets covered by this seal: Signature O L NAEROF NSCEEWOI AIDLP TCECTIHA RSS I IA Reg. # Date ARCHITECT As listed above June 30, 2023 Michael W. Simonson 2704 Michael W. Simonson 2704 24"x36" SHEET (FULL SIZE) - SCALE IS AS NOTED. 12"x18" SHEET (HALF SIZE) - SCALE IS ONE-HALF OF WHAT IS NOTED OTHER SHEET SIZES NOT TO SCALE SCALE NOTE: - DOOR INDICATOR - FINISH INDICATOR - KEYNOTE - REVISION INDICATOR - ROOM INDICATOR - HORIZONTAL & VERTICAL ASSEMBLY TYPE IDENTIFIER - WINDOW INDICATOR LEGEND: - - - - - NOTE: THIS DRAWING DOES NOT REPRESENT AN AS-BUILT CONDITION. ACTUAL DETAILS AND DIMENSIONS MAY VARY AND ARE SUBJECT TO CHANGE. AS-BUILT CONDITIONS MUST BE FIELD VERIFIED PRIOR TO FINAL LAYOUT AND CONSTRUCTION OF INTERIOR TENANT IMPROVEMENTS. NOTE: ALL DESIGN DOCUMENTS ARE SUBJECT TO AUTHORITIES HAVING JURISDICTION REVIEW AND APPROVAL. - - INDEX OF DRAWINGS ARCHITECTURAL A-001 ASSEMBLIES, DOORS & WINDOW TYPES A-101 FIRST FLOOR PLAN A-102 SECOND FLOOR PLAN A-103 THIRD FLOOR PLAN A-111 ROOF PLAN A-121 REFLECTED CEILING PLAN A-122 REFLECTED CEILING PLAN A-123 REFLECTED CEILING PLAN A-201 EXTERIOR ELEVATIONS A-202 EXTERIOR ELEVATIONS A-301 BUILDING SECTIONS A-311 WALL SECTIONS A-321 STAIR PLANS & SECTIONS A-411 UNIT PLANS A-412 UNIT PLANS A-413 UNIT PLANS A-501 DETAILS A-502 DETAILS A-801 GARAGE PLANS & ELEVATIONS A-802 GARAGE ROOF PLANS & SECTIONS GENERAL G-000 COVER SHEET G-001 SPECIFICATION NOTES G-011 ACCESSIBILITY REQUIREMENTS & GUIDELINES G-101 CODE REVIEW NEW CONSTRUCTION PLANS FOR CONVERGE NW APARTMENTS WAUKEE, IA Rev. #Issue / RevisionDate130% Set12-03-2021STRUCTURAL S-001 STRUCTURAL NOTES S-101 FOUNDATION PLAN S-102 FOUNDATION PLAN - GARAGES S-201 FOUNDATION DETAILS S-301 FRAMING PLAN - SECOND FLOOR S-302 FRAMING PLAN - THIRD FLOOR S-303 FRAMING PLAN - ROOF PLAN S-304 FRAMING PLAN - GARAGES S-401 FRAMING DETAILS S-402 FRAMING DETAILS S-403 FRAMING DETAILS KEY PLAN FRIG. DW FRIG. DW WHFURN.WDWDWHFRIG. DW FURN.WDWHFRIG. DW FURN.WDWHFRIG. DW FURN.WDWHFRIG. DW FURN.WDWHFRIG. DW FURN.UP FRIG. DW WD WHFURN. W D WHFURN. FRIG. DW WD WHFURN.WDWHFRIG. DW FURN.FRIG. DW W D WHFURN.WDWHFRIG. DW FURN.W WH FURN. D FRIG. DWDWFRIG.DWWH FURN. FRIG. DW FRIG. DW FRIG. DW WDWHFRIG. DW FURN.WDWHFRIG. DW FURN.WDWHFRIG. DW FURN.WDWHFRIG. DW FURN.DWFRIG.DWWH FURN. FRIG. DW W D WHFURN. WD WHFURN. WD WHFURN. W D WHFURN. FRIG. DW WD WHFURN. FRIG. DWWHFURN. UP 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL SITE INFO, FURNITURE, FIXTURES AND EQUIPMENT SHOWN SHOULD BE CONSIDERED CONCEPTUAL AND MAY HAVE BE PROVIDED FOR COORDINATION PURPOSES ONLY. REFER TO CIVIL, FIRE SUPPRESSION, PLUMBING, MECHANICAL, ELECTRICAL, COMMUNICATIONS, ELECTRONIC SAFETY & SECURITY DOCUMENTS &/OR CONSULTANTS FOR SPECIFIC DESIGN INFORMATION & REQUIREMENTS. 3. DIMENSIONS ARE TO FACE OF FINISH MATERIAL OR CENTER OF STRUCTURE UNLESS OTHERWISE SPECIFIED. 4. ALL CONDUITS, PIPES, WIRING, ROUGH-IN, ETC. SHOULD BE HELD AS TIGHT AS POSSIBLE TO THE ROOF OR FLOOR DECK OR SHOULD BE KEPT WITHIN INTERIOR WALL CAVITIES. NOTHING SHALL BE BELOW THE BOTTOM EDGE OF MAIN BUILDING FRAMES, NOTHING SHALL BE EXPOSED IN FINISHED SPACES, NOTHING SHALL PREVENT A SMOOTH CONTINUOUS FINISHED WALL OR CEILING AS NOTED ON THE DRAWINGS AND NO PLUMBING RAN IN EXTERIOR WALLS UNLESS PRIOR APPROVAL IS GRANTED BY THE ARCHITECT OR OWNER. PLACEMENT COORDINATION BETWEEN TRADES IS REQUIRED. 5. INSTALL VERTICAL EXPANSION JOINT MINIMAL AT COLUMN/GRID LINES AND AT THE HEAD OF DOOR JAMBS/OPENINGS OR AS OTHERWISE NOTED OR WHERE REQUIRED PER STANDARD MATERIAL PRACTICE TO REDUCE STRESS CRACKING. NO CONTROL JOINT/EXPANSION JOINT IN LOAD BEARING AREAS, STAY AWAY 2'-6" MIN. 6. CAULK & SEAL ALL CONTROL-EXPANSION, SAWCUT JOINTS AT ALL INTERIOR & EXTERIOR MASONRY & CONCRETE. 7. PROVIDE LOWER LEVEL AND/OR UNDERFLOOR DRAINAGE SYSTEM TO REDUCE HYDROSTATIC UPLIFT AND PROTECT AGAINST MOISTURE SEEPAGE. PROVIDE FOUNDATION WALL DRAINAGE SYSTEM TO REDUCE LATERAL PRESSURES AND PROTECT AGAINST MOISTURE SEEPAGE. BOTH SYSTEMS SHALL OUTLET TO APPROPRIATE RELIEF. 8. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM BUILDING WITHOUT PONDING OF WATER ADJACENT TO BUILDING OR ON PAVEMENTS. GENERAL FLOOR PLAN NOTES M-104 1 CORRIDOR C101 UNIT 114 UNIT 2A 1018 SF UNIT 110 UNIT 2A 1018 SF UNIT 116 UNIT 1A 717 SF UNIT 118 UNIT 2B 1018 SF UNIT 109 UNIT 2A 1018 SF UNIT 115 UNIT 1A 717 SF UNIT 117 UNIT 1A 717 SF UNIT 113 UNIT 2A 1018 SF UNIT 120 UNIT 1B 650 SF UNIT 108 UNIT 1A 717 SF DATA C104 UNIT 119 UNIT 1A 717 SF SPRINK. C102 UTILITY C103 UNIT 112 UNIT 1A 717 SF UNIT 111 UNIT 1A 717 SF 35' - 6"25' - 0"35' - 6" 35' - 6" 35' - 6"25' - 0"35' - 6"25' - 0"25' - 0"25' - 0"18' - 4 1/2" M-105 1 M-104 M-105 5' - 0" 7' - 11" 6' - 0" 4' - 4" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 7' - 10 1/4" 5' - 0" 7' - 11 3/4" 6' - 0" 4' - 4" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 7' - 7 3/4" 5' - 0" 8' - 2 1/4" 6' - 0" 4' - 4" 2' - 6" 5' - 0" 2' - 6" 4' - 3" 6' - 0" 4' - 4 1/2"2' - 10 1/2"2' - 0" 6' - 2" 5' - 0" 20' - 4"41' - 6"20' - 4"41' - 6"10' - 0" 14' - 7 1/2"5' - 0" 13' - 2" 12' - 0" 2' - 0" 7' - 0" 6' - 0" 8' - 2"5' - 0"17' - 5 3/4"6' - 0" 4' - 4" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 7' - 11" 5' - 0" 7' - 11" 6' - 0" 4' - 4" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 7' - 11" 5' - 0" 7' - 11" 6' - 0" 4' - 0" 3' - 0" 1' - 3 1/4" 7' - 0" 11' - 3 3/4" 7' - 0" 1' - 5 1/4" 3' - 0" 3' - 6" 6' - 0" 7' - 9" 5' - 0" 20' - 4"41' - 6"20' - 4"45' - 5 1/4"25' - 3 3/4"3' - 8"A-202 3 A-202 4 A-201 1 A-201 8 A-2013 A-321 1 1 A-301 1 A-301 U109 U108 U111 U110 U113 U112 U114 U115 U117 U116 C104 C101.1 U120 U118 U119 STAIR 1 S001 C103 C102 C100.1 BELOW ABOVE BELOW ABOVE ABOVE BELOW ABOVE BELOW ABOVE BELOW BELOW ABOVE BELOW ABOVE B B B B AA B B B B B B A A A A28' - 8 1/8"7 3/4"5' - 0"7 3/4"A A A A A A A A C A A C A ABBAAAAAAFFFFFF F F F F F F F 327'-0" (TYPE A) 25' - 0" L 12' - 4" M-104 1 M-104 2 M-105 1 M-104 M-1052 A-301 2 A-301 CORRIDOR C101 UNIT 104 UNIT 2A 1018 SF UNIT 103 UNIT 1A 717 SF UNIT 101 UNIT 3A 1362 SF UNIT 102 UNIT 3A 1362 SF MECH C10531' - 6"31' - 6"35' - 6"35' - 6"25' - 0"35' - 6" 44' - 7 1/4" 44' - 7 3/4"25' - 0"35' - 6"25' - 0"35' - 6"25' - 0"5' - 0"11' - 8"5' - 0"5' - 0"6' - 0"5' - 0"5' - 0"11' - 8"5' - 0"26' - 0"7 3/4"5' - 0"7 3/4"28' - 8 1/8"5' - 0" 11' - 6" 5' - 3" 6' - 0" 5' - 3" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 7' - 11" 5' - 0" 7' - 11" 6' - 0" 4' - 4" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 7' - 11" 5' - 0" 7' - 11" 6' - 0" 4' - 4" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 7' - 10 1/4" 16' - 6" 20' - 4"41' - 6"20' - 4"41' - 6"20' - 4" 5' - 0" 10' - 0" 5' - 4" 6' - 0" 5' - 4" 3' - 0" 5' - 0" 2' - 10" 11' - 10 3/4" 2' - 5 15/16"5' - 0" 3' - 0" 4' - 8" 6' - 0" 3' - 10" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 7' - 11" 5' - 0" 7' - 11" 6' - 0" 4' - 4" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0"7' - 11" 5' - 0" 7' - 11" 16' - 8" 10' - 10" 11' - 10 3/4" 10' - 6" 14' - 6" 20' - 4"41' - 6"20' - 4" 12' - 0" A-202 3 A-202 4 A-201 1 A-201 8 A-201 2 A-321 5 UNIT 105 UNIT 2A 1018 SF UNIT 106 UNIT 2A 1018 SF UNIT 107 UNIT 1A 717 SF UNIT 109 UNIT 2A 1018 SF UNIT 108 UNIT 1A 717 SF UNIT 110 UNIT 2A 1018 SF UNIT 111 UNIT 1A 717 SF U101 U102 C101.2 C105 U103 U104 U105 U107 U106 U109 U108 U110 U111 STAIR 2 S002 C100.2 BELOW ABOVE BELOW ABOVE BELOW ABOVE BELOW ABOVE BELOW ABOVE 1 B A A A A B B B B B B B B B B BELOW ABOVE BELOW ABOVE BELOW ABOVE AAAAAAAAA A A A A A A A A A A A A AFFFFF FFFFFF 327'-0" (TYPE A) L This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.Sheet No. Sheet Title Job No.Proj. Mgr.12/3/2021 5:51:42 AMJ:\2021\21113 Waukee Crossing Multi-Family - Hubbell\CAD-Arch\21113 Converge NW, Waukee, IA_60 Unit Apartment.rvt21113 SP FIRST FLOOR PLAN A-101CONVERGE NWAPARTMENTSWAUKEE, IASCALE:1/8" = 1'-0"1 FIRST FLOOR PLAN Rev. #Issue / RevisionDate130% Set12-03-2021REFER TO CIVIL FOR ORIENTATION W WH FURN. D FRIG. DW FRIG. DW FRIG. DW WHFURN.WDWDWHFRIG. DW FURN.WDWHFRIG. DW FURN.WDWHFRIG. DW FURN.WDWHFRIG. DW FURN.UP UP UP FRIG. DW WD WHFURN. W D WHFURN.FRIG. DW W D WHFURN.WDWHFRIG. DW FURN.FRIG. DW WD WHFURN.WDWHFRIG. DW FURN.WDWHFRIG. DW FURN.DWFRIG.DWWH FURN. FRIG. DW FRIG. DW WDWHFRIG. DW FURN.WDWHFRIG. DW FURN.WDWHFRIG. DW FURN.DWFRIG.DWWH FURN. FRIG. DW WD WHFURN. WD WHFURN. W D WHFURN.WHFURN. FRIG. DW WD WHFURN. FRIG. DW UP UP UP WDWHFRIG. DW FURN.FRIG. DW W D WHFURN. 1 CORRIDOR C201 DATA C202 M-105 1 M-104 M-105 12' - 0" 14' - 9 1/4" 20' - 4" 14' - 8 1/4" 12' - 0" 14' - 9 3/4" 20' - 4" 14' - 7 3/4" 11' - 8" 15' - 2 1/4" 10' - 0" 14' - 7 1/2" 7' - 6 1/2" 12' - 8"12' - 8"14' - 2 1/4"17' - 5 3/4"9' - 0"13' - 4"20' - 4" 14' - 10 1/8" 12' - 0" 14' - 7 7/8" 20' - 4" 14' - 9 1/4" 12' - 0" 18' - 8"13' - 4"3' - 4"6' - 0"3' - 4"3' - 4" 6' - 0" 3' - 4" A-202 3 A-202 4 A-201 1 A-201 8 A-2013A-321 2 UNIT 214 UNIT 2A 1029 SF UNIT 216 UNIT 1A 717 SF UNIT 215 UNIT 1A 717 SF UNIT 217 UNIT 1A 728 SF UNIT 220 UNIT 1B 673 SF UNIT 208 UNIT 1A 717 SF UNIT 219 UNIT 1A 717 SF UNIT 212 UNIT 1A 717 SF UNIT 211 UNIT 1A 717 SF UNIT 210 UNIT 2A 1029 SF UNIT 218 UNIT 2B 1043 SF UNIT 209 UNIT 2A 1029 SF UNIT 213 UNIT 2A 1029 SF 7' - 0 5/8" 11' - 3 3/8" 7' - 0" 17' - 6"4' - 2"5' - 0"3' - 6"4' - 6"6' - 0"3' - 8 1/4"3' - 5 3/4"2' - 0"12' - 0"9' - 0"4' - 2"5' - 0"4' - 2"6' - 0" 4' - 4" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 4' - 6 1/8" 3' - 4 1/2" 5' - 0" 3' - 7 1/2"4' - 3 7/8" 6' - 0" 4' - 4" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 4' - 5 1/4" 3' - 4 1/2" 5' - 0" 3' - 7 1/2" 4' - 4 3/4" 6' - 0" 4' - 0" 3' - 0" 1' - 3 1/4" 2' - 0" 3' - 0" 2' - 0 5/8" 11' - 3 3/8" 1' - 11 3/4" 3' - 0" 2' - 0 1/4" 1' - 5" 3' - 0" 3' - 6" 6' - 0" 3' - 7" 4' - 2" 5' - 0" 4' - 2" 3' - 6" 5' - 0" 3' - 6" 4' - 5 1/4" 6' - 0" 4' - 4" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 4' - 4 1/4" 3' - 6" 5' - 0" 3' - 6" 4' - 5 3/4" 6' - 0" 4' - 4" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 4' - 3 3/4" 3' - 4" 5' - 0" 3' - 4" 4' - 10 1/4" 6' - 0" 4' - 4" 2' - 6" 5' - 0" 2' - 6" 4' - 3" 6' - 0" 4' - 4 1/2" 2' - 10 1/2" 2' - 0" 2' - 8" 3' - 6" 5' - 0" 4' - 2" 1 A-301 1 A-301 STAIR 1 001 2 2 2 2 2 2 2 2 22 A A A A A A B BB B B B B B B B B A U220 U219 U218 C202 C201.1 U216 U217U215 U214 U213 U212 U211 U210 U209 U208 A A A A A A A C A A C A A BBBB A AA A AA F FFFFF F F F F F F F 329'-0"1' - 0"28' - 8 1/8"7 3/4"5' - 0"7 3/4"28' - 8 1/8"1' - 0"35' - 6"25' - 0"35' - 6"25' - 0"25' - 0"25' - 0"18' - 4 1/2" 35' - 6"25' - 0"35' - 6"25' - 0" 35' - 6" 12' - 4" 4" / 12" 4" / 12"4" / 12" L 1 M-104 2 M-105 1 M-104 M-1052 A-301 2 A-301 CORRIDOR C201 MECH C2031' - 0"2' - 8"5' - 0"3' - 7"8' - 1"8' - 1"3' - 7"5' - 0"2' - 8"1' - 0"12' - 3"8' - 1"26' - 0"8' - 1"12' - 3"66' - 8"12' - 3" 8' - 1" 16' - 6" 20' - 4" 14' - 9 1/4" 12' - 0"14' - 8 3/4" 20' - 4" 14' - 8 3/4" 12' - 0" 14' - 9 1/4" 20' - 4" 14' - 8 1/4" 12' - 3" 6' - 9" 16' - 8" 11' - 4" 10' - 10 3/4" 11' - 0" 14' - 6" 20' - 4" 14' - 10 1/2" 12' - 0" 14' - 7 1/2" 20' - 4" 14' - 10 1/8" 12' - 0" 12' - 0" 3' - 4" 6' - 0" 3' - 4" A-202 3 A-202 4 A-201 1 A-201 8 A-201 2 A-321 6 UNIT 204 UNIT 2A 1018 SF UNIT 203 UNIT 1A 717 SF UNIT 207 UNIT 1A 717 SFUNIT 201 UNIT 3A 1383 SF UNIT 208 UNIT 1A 717 SF UNIT 206 UNIT 2A 1029 SF UNIT 211 UNIT 1A 717 SF UNIT 202 UNIT 3A 1383 SF UNIT 210 UNIT 2A 1029 SF UNIT 209 UNIT 2A 1029 SF UNIT 205 UNIT 2A 1029 SF 5' - 0"5' - 0"6' - 0"5' - 0"5' - 0"3' - 10" 5' - 0" 3' - 5" 8' - 1" 5' - 3" 6' - 0" 5' - 3" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 4' - 5 1/4" 3' - 6" 5' - 0" 3' - 6" 4' - 4 3/4" 6' - 0" 4' - 4" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 4' - 4 3/4" 3' - 6" 5' - 0" 3' - 6" 4' - 5 1/4" 6' - 0"4' - 4" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 4' - 4 1/4" 4' - 0" 5' - 0" 3' - 3" 6' - 9" 5' - 4" 6' - 0" 5' - 4" 3' - 0" 5' - 0" 3' - 4" 5' - 0" 3' - 0" 4' - 8" 6' - 0" 3' - 10" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 4' - 6 1/2" 3' - 4 1/2" 5' - 0" 3' - 7 1/2" 4' - 3 1/2" 6' - 0" 4' - 4" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 4' - 6 1/8" 3' - 4 1/2" 5' - 0" 3' - 7 1/2"7 3/4"5' - 0"7 3/4"2 2 2 2 A A A A A B B B B B BB B B B B STAIR 2 002 U201 U202 C203 C201.2 U203 U204 U205 U206 U207 U209 U208 U211 U210U202 A A A A A A A A A A A A A A A A A A A AA A F F F F F FFFFFF 329'-0" 35' - 6"35' - 6"25' - 0"35' - 6" 44' - 7 1/4" 44' - 7 3/4" 25' - 0"35' - 6"25' - 0"35' - 6"25' - 0" 4" / 12" L This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.Sheet No. Sheet Title Job No.Proj. Mgr.12/3/2021 5:51:45 AMJ:\2021\21113 Waukee Crossing Multi-Family - Hubbell\CAD-Arch\21113 Converge NW, Waukee, IA_60 Unit Apartment.rvt21113 SP SECOND FLOOR PLAN A-102CONVERGE NWAPARTMENTSWAUKEE, IASCALE:1/8" = 1'-0"1 SECOND FLOOR Rev. #Issue / RevisionDate130% Set12-03-2021REFER TO CIVIL FOR ORIENTATION FRIG. DW FRIG. DW WHFURN.WDWDWHFRIG. DW FURN.WDWHFRIG. DW FURN.WDWHFRIG. DW FURN.WDWHFRIG. DW FURN.WDWHFRIG. DW FURN.UP UP FRIG. DW WD WHFURN. W D WHFURN. FRIG. DW WD WHFURN.WDWHFRIG. DW FURN.FRIG. DW W D WHFURN.WDWHFRIG. DW FURN.W WH FURN. D FRIG. DWDWFRIG.DWWH FURN. FRIG. DW FRIG. DW FRIG. DW WDWHFRIG. DW FURN.WDWHFRIG. DW FURN.WDWHFRIG. DW FURN.WDWHFRIG. DW FURN.DWFRIG.DWWH FURN. FRIG. DW W D WHFURN. WD WHFURN. WD WHFURN. W D WHFURN. FRIG. DW WD WHFURN. FRIG. DWWHFURN. UP UP 1 UNIT 314 UNIT 2A 1029 SF UNIT 316 UNIT 1A 717 SF UNIT 315 UNIT 1A 717 SF UNIT 317 UNIT 1A 728 SF UNIT 320 UNIT 1B 673 SF UNIT 308 UNIT 1A 717 SF UNIT 319 UNIT 1A 717 SF UNIT 312 UNIT 1A 717 SF DATA C302 M-105 1 M-104 M-105 CORRIDOR C301 12' - 0" 14' - 9 1/4" 20' - 4" 14' - 8 1/4" 12' - 0" 14' - 9 3/4" 20' - 4" 14' - 7 3/4" 11' - 8" 15' - 2 1/4" 10' - 0" 14' - 7 1/2" 7' - 6 1/2" 12' - 8"12' - 8"31' - 8"9' - 0"13' - 4"20' - 4" 14' - 10 1/8" 12' - 0" 14' - 7 7/8" 20' - 4" 14' - 9 1/4" 12' - 0" 18' - 8"13' - 4"3' - 4"6' - 0"3' - 4"3' - 4" 6' - 0" 3' - 4" 7' - 0 5/8" 11' - 3 3/8" 7' - 0" 17' - 6" 6' - 0" 4' - 4" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 4' - 6 1/8" 3' - 4 1/2" 5' - 0" 3' - 7 1/2" 4' - 3 7/8" 6' - 0" 4' - 4" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 4' - 5 1/4" 3' - 4 1/2" 5' - 0" 3' - 7 1/2" 4' - 4 3/4" 6' - 0" 4' - 0" 3' - 0" 1' - 3 1/4" 2' - 0" 3' - 0" 2' - 0 5/8" 4' - 1 3/8" 3' - 0" 4' - 2" 1' - 11 3/4"3' - 0" 1' - 9 1/4" 1' - 8" 3' - 0" 3' - 6" 6' - 0" 3' - 7" 4' - 2" 5' - 0" 4' - 2"4' - 2"5' - 0"3' - 6"4' - 6"6' - 0"3' - 8 1/4"3' - 5 3/4"2' - 0"12' - 0"9' - 0"4' - 2"5' - 0"4' - 2"3' - 6" 5' - 0" 3' - 6" 4' - 5 1/4" 6' - 0" 4' - 4" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 4' - 4 1/4" 3' - 6" 5' - 0" 3' - 6" 4' - 5 3/4" 6' - 0" 4' - 4" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 4' - 3 3/4" 3' - 4" 5' - 0" 3' - 4" 4' - 10 1/4" 6' - 0" 4' - 4" 2' - 6" 5' - 0" 2' - 6" 4' - 3" 6' - 0" 4' - 4 1/2" 2' - 10 1/2" 2' - 0" 2' - 8" 3' - 6" 5' - 0" 4' - 2" A-202 3 A-202 4 A-201 1 A-201 8 A-2013A-321 3 UNIT 310 UNIT 2A 1029 SF UNIT 318 UNIT 2B 1043 SF UNIT 309 UNIT 2A 1029 SF UNIT 313 UNIT 2A 1029 SF 1 A-301 1 A-301 U309 U308 U310 U311 U313 U312 U315 U314 U316 U317 C301.1 C302 U319 U318 U320 STAIR 1 001 A CA A AA A AA A A A A A A A B B B B A A C A 2 2 2 2 2 2 2 22 22 B B B B A B B B B B B B A A A A A A F FFFFF F F F F F F F 329'-0" E D 35' - 6"25' - 0"35' - 6"25' - 0"25' - 0"25' - 0"18' - 4 1/2" 35' - 6" 12' - 4"25' - 0"35' - 6"25' - 0"35' - 6" UNIT 311 UNIT 1A 717 SF L 1 M-104 2 M-105 1 M-104 M-1052 A-301 2 A-301 UNIT 304 UNIT 2A 1018 SF UNIT 303 UNIT 1A 717 SF UNIT 307 UNIT 1A 717 SFUNIT 301 UNIT 3A 1383 SF UNIT 308 UNIT 1A 717 SF UNIT 306 UNIT 2A 1029 SF UNIT 311 UNIT 1A 717 SF MECH C303 CORRIDOR C301 12' - 3"8' - 1"26' - 0"8' - 1"12' - 3"66' - 8"12' - 3" 8' - 1" 16' - 6" 20' - 4" 14' - 9 1/4" 12' - 0"14' - 8 3/4" 20' - 4" 14' - 8 3/4" 12' - 0" 14' - 9 1/4" 20' - 4" 14' - 8 1/4" 12' - 3" 6' - 9" 16' - 8"14' - 6" 20' - 4" 14' - 10 1/2" 12' - 0" 14' - 7 1/2" 20' - 4" 14' - 10 1/8" 12' - 0" 12' - 0" 3' - 4" 6' - 0" 3' - 4" 4' - 0" 5' - 0" 3' - 3" 6' - 9" 5' - 4" 6' - 0" 5' - 4" 3' - 0" 5' - 0" 3' - 4" 3' - 11 3/4" 3' - 0" 3' - 11" 3' - 0" 5' - 0" 3' - 0" 4' - 8" 6' - 0" 3' - 10" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 4' - 6 1/2" 3' - 4 1/2" 5' - 0" 3' - 7 1/2" 4' - 3 1/2" 6' - 0" 4' - 4" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 4' - 6 1/8" 3' - 4 1/2" 5' - 0" 3' - 7 1/2" 4' - 3 7/8" 11' - 4" 10' - 10 3/4" 11' - 0" 1' - 0" 2' - 10" 5' - 0" 3' - 5" 8' - 1" 5' - 3" 6' - 0" 5' - 3" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 4' - 5 1/4" 3' - 6" 5' - 0" 3' - 6" 4' - 4 3/4" 6' - 0" 4' - 4" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 4' - 4 3/4" 3' - 6" 5' - 0" 3' - 6" 4' - 5 1/4" 6' - 0" 4' - 4" 3' - 4" 5' - 0" 3' - 8" 5' - 0" 3' - 4" 4' - 4" 6' - 0" 4' - 4 1/4" 3' - 6"3' - 8"5' - 0"3' - 7"8' - 1"5' - 0"5' - 0"6' - 0"5' - 0"5' - 0"8' - 1"3' - 7"5' - 0"3' - 8"A-202 3 A-202 4 A-201 1 A-201 8 A-201 2 A-321 7 UNIT 302 UNIT 3A 1383 SF UNIT 310 UNIT 2A 1029 SF UNIT 309 UNIT 2A 1029 SF UNIT 305 UNIT 2A 1029 SF A A A A A A A A A A A A A A A A A A A A A A U302 U301 U303 C301.2 C303 U304 U305 U306 U307 U308 U309 U310 U311 STAIR 2 002 2 2 2 2 2 2 2 2 2 2 2 B B B B B B B B B B B A A A A A F F F F F F FFFFFF 329'-0" E D 35' - 6"35' - 6"25' - 0"35' - 6" 44' - 7 3/4"25' - 0"35' - 6"25' - 0"35' - 6"25' - 0" L This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.Sheet No. Sheet Title Job No.Proj. Mgr.12/3/2021 5:51:49 AMJ:\2021\21113 Waukee Crossing Multi-Family - Hubbell\CAD-Arch\21113 Converge NW, Waukee, IA_60 Unit Apartment.rvt21113 SP THIRD FLOOR PLAN A-103CONVERGE NWAPARTMENTSWAUKEE, IASCALE:1/8" = 1'-0"1 THIRD FLOOR Rev. #Issue / RevisionDate130% Set12-03-2021REFER TO CIVIL FOR ORIENTATION 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL FIXTURES AND EQUIPMENT SHOWN SHOULD BE CONSIDERED CONCEPTUAL AND MAY BE PROVIDED FOR COORDINATION PURPOSES ONLY. REFER TO CIVIL, FIRE SUPPRESSION, PLUMBING, MECHANICAL, ELECTRICAL, COMMUNICATIONS, ELECTRONIC SAFETY & SECURITY DOCUMENTS &/OR CONSULTANTS FOR SPECIFIC DESIGN INFORMATION & REQUIREMENTS. REFER TO STRUCTURAL DRAWINGS FOR ROOF OPENING STRUCTURAL FRAMING. 3. ALL ROOF PENETRATIONS FOR MINOR ROOF VENTS AND SIMILAR ITEMS MAY NOT BE INDICATED ON THE ROOF PLAN: HOWEVER, ALL ROOF FLASHING WORK SHALL BE PROVIDED BY THE ROOFING SUBCONTRACTOR SO AS TO OBTAIN FULL ROOFING WARRANTIES. REFER TO ALL OTHER CONSTRUCTION DOCUMENTS FOR ADDITIONAL ROOF PENETRATIONS REQUIRING ROOF FLASHING WORK. 4. IT SHOULD BE THE RESPONSIBILITY OF THE ROOF SUB-CONTRACTOR TO PROVIDE ALL NECESSARY DETAILS AND SYSTEMS TO ACCOMMODATE EXPANSION/CONTRACTION OF THE BUILDING AND BUILDING COMPONENTS FOR A LONG-LASTING ROOF. 5. CONTRACTOR SHALL KEEP ROOF CLEAN OF ALL DEBRIS DURING ALL CONSTRUCTION WORK. 6. ROOF SYSTEM AND ANY WORK ASSOCIATED WITH THE ROOF SHALL BE DONE AS TO NOT VOID ANY ROOF WARRANTIES. 7. FLASHING: A. FLASHING SHALL BE INSTALLED IN SUCH A MANNER SO AS TO PREVENT MOISTURE ENTERING THE WALL AND ROOF THROUGH JOINTS IN COPINGS & AT INTERSECTIONS WITH PARAPET WALLS & OTHER PENETRATIONS THROUGH THE ROOF PLANE. B. FLASHING SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, AT GUTTERS, WHEREVER THERE IS A CHANGE IN ROOF SLOPE OR DIRECTION AND AROUND ROOF OPENINGS. WHERE FLASHING IS METAL, THE METAL SHALL BE CORROSION RESISTANT WITH A THICKNESS OF NOT LESS THAN 0.019”, NO. 26 GALVANIZED SHEET. 8. ROOF DRAINAGE: A. DESIGN OF ROOF DRAINAGE SYSTEMS SHALL COMPLY WITH THE INT'L PLUMBING CODE. FINAL DETAILED DESIGN OF ROOF DRAINAGE SYSTEMS TO BE BY PLUMBING CONSULTANT. B. OVERSIZED ROOF DRAINS, GUTTERS AND/OR DOWNSPOUTS SHOULD BE PROVIDED TO ELIMINATE ANY OVERFLOW OR BACKUP. C. NOT LESS THAN 2 ROOF DRAINS SHALL BE INSTALLED IN ROOF AREAS 10,000 SF OR LESS AND NOT LESS THAN FOUR ROOF DRAINS SHALL BE INSTALLED IN ROOFS OVER 10,000 SF IN AREA. D. WHERE ROOF DRAINS ARE REQUIRED, SECONDARY (EMERGENCY) ROOF DRAINS OR SCUPPERS SHALL BE PROVIDED WHERE THE ROOF PERIMETER CONSTRUCTION EXTENDS ABOVE THE ROOF IN SUCH A MANNER THAT WATER WILL BE ENTRAPPED IF THE PRIMARY DRAINS ALLOW BUILDUP FOR ANY REASON. a. SECONDARY ROOF DRAIN SYSTEMS SHALL HAVE THE END POINT OF DISCHARGE SEPARATE FROM THE PRIMARY SYSTEM. DISCHARGE SHALL BE ABOVE GRADE, IN A LOCATION THAT WOULD NORMALLY BE OBSERVED BY THE BUILDING OCCUPANTS OR MAINTENANCE PERSONNEL. b. SECONDARY SCUPPERS SHALL BE SIZED TO PREVENT THE DEPTH OF PONDING WATER FROM EXCEEDING THAT FOR WHICH THE ROOF WAS DESIGNED. THEY SHALL HAVE AN OPENING DIMENSION OF NOT LESS THAN 4”. c. A CRICKET OR SADDLE SHALL BE INSTALLED ON THE RIDGE SIDE OF ANY PENETRATION GREATER THAN 30" WIDE AS MEASURED PERPENDICULAR TO THE SLOPE. d. ALL ROOF SLOPES, INCLUDING FLATTENED ROOF AREAS TO OBTAIN POSITIVE DRAINAGE, TO BE INTEGRATED INTO UNDERLYING ROOF SUPPORT DESIGN. PROVIDE TAPERED RIGID INSULATION TO MAINTAIN MINIMUM 1/4" PER FOOT SLOPE AT ALL FLATTENED ROOF AREAS TO ENSURE POSITIVE DRAINAGE ALL THE WAY TO ROOF DRAIN FROM ALL PENETRATIONS AND CHANGES IN ROOF SLOPES. E. PROVIDE CONCRETE SPLASH BLOCKS AT ALL DOWNSPOUT LOCATIONS. 9. ROOF VENTILATION INTAKE & EXHAUST VENTS SHALL BE PROVIDED IN EACH & ALL ENCLOSED ATTICS &/OR RAFTER SPACES TO CREATE CROSS VENTILATION IN ACCORDANCE WITH CODES & THE MANUFACTURES INSTALLATION INSTRUCTIONS. 10. INSULATE AND SEAL TO ENSURE ADEQUATE AIR INFILTRATION BARRIER AROUND ALL EXTERIOR PENETRATIONS TO PREVENT WATER AND SPRINKLER PIPE FREEZING. 11. ACCESS TO UNOCCUPIED SPACES A. CRAWL SPACES SHALL BE PROVIDED WITH NO FEWER THAN 1 ACCESS OPENING WHICH SHALL NOT BE LESS THAN 18" X 24". B. AN OPENING OF NOT LESS THAN 20"X30" SHALL BE PROVIDED TO ANY ATTIC AREA HAVING A CLEAR HEIGHT OF OVER 30". CLEAR HEADROOM OF NOT LESS THAN 30" SHALL BE PROVIDED IN THE ATTIC SPACE AT OR ABOVE THE ACCESS OPENING. C. ACCESS TO MECHANICAL APPLIANCES INSTALLED IN UNDER FLOOR AREAS, IN ATTIC SPACES AND ON ROOFS OR ELEVATED STRUCTURES SHALL BE IN ACCORDANCE WITH THE INT'L MECHANICAL CODE. a. ATTICS CONTAINING APPLIANCES SHALL BE PROVIDED WITH AN OPENING AND UNOBSTRUCTED PASSAGEWAY LARGE ENOUGH TO ALLOW REMOVAL OF THE LARGEST APPLIANCE. THE PASSAGEWAY SHALL NOT BE LESS THAN 30”H X 22”W AND NOT MORE THAN 20’ IN LENGTH MEASURED ALONG THE CENTERLINE OF THE PASSAGEWAY FROM THE OPENING TO THE APPLIANCE. THE PASSAGEWAY SHALL HAVE CONTINUOUS SOLD FLOORING NOT LESS THAN 24” WIDE. A LEVEL SURFACE SPACE NOT LESS THAN 30”D X 30”W SHALL BE PRESENT AT THE FRONT OF SERVICE SIDE OF THE APPLIANCE. 12. PROVIDE ROOF SNOW GUARDS/SPIKES ABOVE ALL ENTRY/EXIT POINTS TO BUILDING. 13. ROOF TRUSSES DESIGN BUILD BY TRUSS MANUFACTURER. 14. ASPHALT SHINGLES: A. ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF SLOPES OF 2:12 OR GREATER. B. FOR ROOF SLOPES FROM 2:12 (17%) & UP TO 4:12 (33%), UNDERLAYMENT SHALL BE 2 LAYERS APPLIED IN THE FOLLOWING MANNER. APPLY A MINIMUM 19” WIDE STRIP OF UNDERLAYMENT FELT PARALLEL WITH & STARTING AT THE EAVES, FASTENED SUFFICIENTLY TO HOLD IN PLACE. STARTING AT THE EAVE, APPLY 36” WIDE SHEETS OF UNDERLAYMENT OVERLAPPING SUCCESSIVE SHEETS 19”, BY FASTENED SUFFICIENTLY TO HOLD IN PLACE. C. FOR ROOF SLOPES OF 4:12 (33%) OR GREATER, UNDERLAYMENT SHALL BE ONE LAYER APPLIED IN THE FOLLOWING MANNER. UNDERLAYMENT SHALL BE APPLIED SHINGLE FASHION, PARALLEL TO & STARTING FROM THE EAVE & LAPPED 2”, FASTENED SUFFICIENTLY TO HOLD IN PLACE. D. AN ICE BARRIER THAT CONSISTS OF AT LEAST TWO LAYER OF UNDERLAYMENT CEMENTED TOGETHER OR OF A SELF-ADHERING POLYMER MODIFIED BITUMEN SHEET SHALL BE USED IN LIEU OF NORMAL UNDERLAYMENT AND EXTEND FROM THE LOWEST EDGES OF ALL ROOF SURFACES TO A POINT AT LEAST 24" INSIDE THE EXTERIOR WALL LINE OF THE BUILDING. GENERAL ROOF PLAN NOTES DRAFTSTOPPING ONLY REQUIRED IN COMBUSTIBLE BUILDINGS WITHOUT AUTOMATIC SPRINKLER SYSTEMS THROUGHOUT. 1. DRAFTSTOPPING IN FLOORS SHALL BE INSTALLED TO SUBDIVIDE FLOOR/CEILING ASSEMBLIES: A. GROUPS ALL R-1; R-2 WITH 3 OR MORE DWELLING UNITS; R-3 WITH 2 DWELLING UNITS; & ALL R-4 BUILDINGS – SHALL BE LOCATED ABOVE & IN-LINE WITH THE DWELLING UNIT AND SLEEPING UNIT SEPARATIONS. B. ALL OTHER GROUPS – SHALL BE INSTALLED SO THAT HORIZONTAL FLOOR AREAS DO NOT EXCEED 1,000 SF. 2. DRAFTSTOPPING IN ATTICS SHALL BE INSTALLED TO SUBDIVIDE ATTIC SPACES & CONCEALED ROOF SPACES: 3. GROUPS ALL R-1; & R-2 WITH 3 OR MORE DWELLING UNITS – SHALL BE LOCATED ABOVE & IN-LINE WITH THE SLEEPING UNIT & DWELLING UNIT SEPARATION W ALLS THAT DO NOT EXTEND TO THE UNDERSIDE OF THE ROOF SHEATHING ABOVE. A. EXCEPTION 1: WHERE CORRIDOR WALLS PROVIDE A SEPARATION, ONLY REQUIRED ABOVE ONE OF THE CORRIDOR WALLS. B. EXCEPTION 3: R-2 THAT DO NOT EXCEED 4 STORIES ABOVE GRADE PLANE, THE ATTIC SPACE SHALL BE SUBDIVIDED INTO AREAS NOT EXCEEDING 3,000 SF OR ABOVE EVERY 2 DWELLING UNITS, WHICHEVER IS SMALLER. A. ALL OTHER GROUPS - SHALL BE INSTALLED SUCH THAT ANY HORIZONTAL AREA DOES NOT EXCEED 3,000 SF. 4. DRAFTSTOPPING MATERIALS SHALL BE NO LESS THAN 1/2" GYP BD, 3/8" WOOD STRUCTURAL PANEL, OR 3/8" PARTICLEBOARD, 1" NOMINAL LUMBER, CEMENT FIBERBOARD, BATTS OR BLANKETS OF MINERAL WOOL OR GLASS FIBER, ADEQUATELY SUPPORTED. 5. OPENINGS IN THE DRAFTSTOPPING SHALL BE PROTECTED BY SELF-CLOSING DOORS W/ AUTOMATIC LATCHES CONSTRUCTED AS REQUIRED FOR THE DRAFTSTOPPING PARTITIONS. DRAFTSTOPPING NOTES 1. PENETRATIONS INTO OR THROUGH FIRE-RESISTIVE-RATED WALL ASSEMBLIES AND HORIZONTAL ASSEMBLIES SHALL BE PROTECTED BY APPROVED PENETRATION FIRESTOP SYSTEMS DESIGNED TO RESIST THE PASSAGE OF FIRE FOR A TIME PERIOD NOT LESS THAN THE REQUIRED FIRE-RESISTANCE RATING WHICH IT IS INSTALLED. 2. ALL JOINTS INSTALLED IN OR BETWEEN FIRE-RESISTIVE-RATED WALLS, FLOORS OR FLOOR/CEILING ASSEMBLIES AND ROOFS OR ROOF/CEILING ASSEMBLIES SHALL BE PROTECTED BY APPROVED FIRE- RESISTANT JOINT SYSTEM DESIGNED TO RESIST THE PASSAGE OF FIRE FOR A TIME PERIOD NOT LESS THAN THE REQUIRED FIRE-RESISTANCE RATING WHICH IT IS INSTALLED. (IBC 2012 Sec. 715) GENERAL ROOF PLAN NOTES M-104 1 M-105 1 M-104 8 M-105 8 A-202 3 A-202 4 A-201 1 A-201 8 A-20134" / 12"4" / 12"4" / 12"4" / 12"4" / 12" 4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12" RC RC PREFINISHED CONTINUOUS OVERSIZED GUTTER OVER PREFINISHED SHEET METAL FASCIA OVER 2X WOOD FASCIA BOARD, TYP. PREFINISHED CONTINUOUS OVERSIZED GUTTER OVER PREFINISHED SHEET METAL FASCIA OVER 2X WOOD FASCIA BOARD, TYP. PROVIDE ICE BARRIER MEMBRANE WHICH SHALL EXTEND FROM THE LOWEST EDGES OF ALL ROOF SURFACES TO A POINT AT LEAST 24" INSIDE THE EXTERIOR WALL LINE OF THE BUILDING AND ALL VALLEYS FIELD CONDITIONS & ROOFING MANUFACTURER'S SPECIFICATIONS PRIOR TO INSTALLATION. INSTALL PER ROOFING & MEMBRANE MANUFACTURER'S INSTRUCTIONS, TYP.@ MAIN ROOF2' - 0" TYP.@ UPPER ROOFS1' - 6" TYP.OUTLINE OF BUILDING BELOW CONTINUOUS RIDGE VENTS, TYP. 4" / 12" 4" / 12"4" / 12" M-104 1 M-104 2 M-105 1 M-104 8 M-105 8 2 A-301 2 A-301 A-202 3 A-202 4 A-201 1 A-201 8 A-201 2 RC 4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12" 4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12" 4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12" RC PROVIDE ICE BARRIER MEMBRANE WHICH SHALL EXTEND FROM THE LOWEST EDGES OF ALL ROOF SURFACES TO A POINT AT LEAST 24" INSIDE THE EXTERIOR WALL LINE OF THE BUILDING AND ALL VALLEYS FIELD CONDITIONS & ROOFING MANUFACTURER'S SPECIFICATIONS PRIOR TO INSTALLATION. INSTALL PER ROOFING & MEMBRANE MANUFACTURER'S INSTRUCTIONS, TYP. CONTINUOUS RIDGE VENTS, TYP.@ MAIN ROOF2' - 0" TYP.@ UPPER ROOFS1' - 6" TYP.A-412 7 PREFINISHED CONTINUOUS OVERSIZED GUTTER OVER PREFINISHED SHEET METAL FASCIA OVER 2X WOOD FASCIA BOARD, TYP. PREFINISHED CONTINUOUS OVERSIZED GUTTER OVER PREFINISHED SHEET METAL FASCIA OVER 2X WOOD FASCIA BOARD, TYP.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.Sheet No. Sheet Title Job No.Proj. Mgr.12/3/2021 5:51:52 AMJ:\2021\21113 Waukee Crossing Multi-Family - Hubbell\CAD-Arch\21113 Converge NW, Waukee, IA_60 Unit Apartment.rvt21113 SP ROOF PLAN A-111CONVERGE NWAPARTMENTSWAUKEE, IASCALE:1/8" = 1'-0"1 ROOF PLAN Rev. #Issue / RevisionDate130% Set12-03-2021 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL CONDUIT RUNS & SERVICE LINES SHALL BE GROUPED TOGETHER IN A NEAT & ORDERLY MANNER AND SHOULD PENETRATE THE WALL AT THE LOWEST POINT AND ARE NOT TO RUN OVER THE TOP OF PARAPET. ALL OTHER CONDUITS & JUNCTION BOXES FOR EXTERIOR FIXTURES & EQUIPMENT SHALL BE FULLY CONCEALED WITHIN THE BUILDING CONSTRUCTION. 3. ALL HORIZONTAL TRANSITIONS BETWEEN DIFFERENT MATERIALS SHALL BE FLASHED CONTINUOUS FROM UP BEHIND UPPER MATERIAL AND EXTEND OVER TO EXTERIOR FACE OF LOWER MATERIAL WITH DRIP EDGE. 4. ANY RETURNS OR BLIND ELEVATIONS NOT SHOWN SHALL BE SIMILAR IN MATERIAL AND MAKEUP TO ADJACENT CONDITIONS OR OTHER SIMILAR CONDITIONS. 5. NO EXPOSED MASONRY/MATERIAL CORES. MASONRY RETURNS AT WINDOWS/OPENINGS ARE REQUIRED IF FRAMING IS NOT DEEP ENOUGH TO PROVIDE CLOSURE AT THE BACKSIDE OF MASONRY FOR AN EFFECTIVELY SEALED JOINT. 6. MATERIALS ABOVE CANOPIES & AWNINGS TO BE CONTINUED DOWN BEHIND THEM U.O.N., TYP. 7. ANY EXPOSED ROOFING MEMBRANE VISIBLE FROM A PUBLIC RIGHT AWAY MUST MATCH THE PRIMARY WALL MATERIAL COLOR. 8. INSTALL VERTICAL EXPANSION JOINTS PER STRUCTURAL OR MINIMAL AT COLUMN/GRID LINES AND AT THE HEAD OF DOOR JAMBS/OPENINGS OR AS OTHERWISE NOTED OR WHERE REQUIRED PER STANDARD MATERIAL PRACTICE TO REDUCE STRESS CRACKING. NO CONTROL JOINT/EXPANSION JOINT AT MAIN STRUCTURAL BEARING LOCATIONS. VERIFY JOINTS WITH ARCHITECT. 9. CAULK & SEAL ALL TRANSITION-CONTROL-EXPANSION AT ALL EXTERIOR MATERIALS. 10. PROVIDE CAST REGLETS JUST IN FROM THE OUTER EDGE ON UNDERSIDE OF FACE MATERIAL OR DRIP EDGE AT ALL OVERHANGS & SOFFITS. 11. INSULATE AND SEAL TO ENSURE ADEQUATE AIR INFILTRATION BARRIER AROUND ALL EXTERIOR PENETRATIONS TO PREVENT WATER AND SPRINKLER PIPE FREEZING. 12. WHERE EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF PAVING TO BE 1/4" LOWER THAN INTERIOR FINISH FLOOR, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. WHERE DOOR STOOP, 48" OUT FROM DOOR 1:48(2%) MAX. SLOPE, AFTER 48" AWAY FROM DOOR 1:20(5%) MAXIMUM SLOPE TO PUBLIC WAY. (REFER TO CIVIL) 13. WHERE NO EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF FINISHED LANDSCAPE A MINIMUM OF 4" BELOW INTERIOR FINISH FLOOR AND 4” BELOW EXTERIOR WALL FLASHING/WEEPS, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. (REFER TO CIVIL) 14. ADDRESS SHALL BE PROVIDED ON STREET SIDE OF BUILDING AND ON MONUMENT SIGN. NUMBERS A MINIMUM 5 INCH CONTRASTING COLOR NUMBERS WITH MINIMUM 1/2" STROKE. 15. IF ANY SIGNAGE OR SIGN BASE IS SHOWN IT IS FOR REFERENCE ONLY, FINAL DESIGNS AND/OR ALLOWANCES SHALL BE DETERMINED WITH APPROVED SIGNAGE PERMIT(S). ACTUAL DETAILS & DIMENSIONS MAY VARY AND ARE SUBJECT TO CHANGE. ALL DRAWINGS ARE SUBJECT TO AUTHORITY HAVING JURISDICTION APPROVAL. SIGNAGE SHOWN DOES NOT REPRESENT ALLOWABLE SIGNAGE PERMITTING/APPROVAL OF ALL SIGNAGE PER CURRENT CITY ORDINANCE BY OTHERS. GENERAL EXTERIOR ELEVATION NOTES TYPICAL U.O.N. • EXPOSED CONCRETE: GRIND SMOOTH & RUB/COAT WITH CEMENT SLURRY. • METAL RAILINGS: GALVANIZED & PAINTED TO MATCH ADJACENT MATERIAL. • FASCIA & SOFFIT: METAL PREFINISHED TO MATCH ADJACENT ROOF COLOR. • SCUPPERS, GUTTERS & DOWNSPOUTS: METAL PREFINISHED TO MATCH ADJ. MATERIAL. • CAULKS & SEALANTS: COLOR MATCHED TO ADJACENT MATERIAL. • HOLLOW METAL MAN DOORS & FRAMES: PAINTED TO MATCH ADJACENT MATERIAL. • OVERHEAD PANEL DOORS: METAL PRE-FINISHED WHITE. • LOUVERS: METAL PRE-FINISHED TO MATCH ADJACENT MATERIAL COLOR. • LIGHT FIXTURES: METAL PRE-FINISHED HOUSINGS TO MATCH ADJ. OPENING FRAMING. • MECHANICAL EQUIPMENT: IF NOT SCREENED, COLOR TO MATCH ADJACENT MATERIAL. • EXTERIOR UTILITY EQUIPMENT: IF ALLOWED, PAINTED TO MATCH ADJACENT MATERIAL. • TRIM SIZES, TYP. U.O.N.: WINDOWS & DOORS 3-1/2” VERTICAL 3-1/2” HORIZONTAL 5-1/2” MISC EXTERIOR MATERIAL FINISHES FIRST FLOOR 100' - 0" THIRD FLOOR 122' - 4 5/8" TRUSS BEARING 131' - 4 7/8" SECOND FLOOR 111' - 2 3/4" ? STN ?? ? STN ? ? ? ? STN FCB-1 STN ?FCP-1 FAS-2 TRM ? FAS-2 RF FCB-1 FCB-1 FCB-1 FCP-1 FCP-1 FCB-2 FCB-2 BRK 1 A-301 B B B B BB B B B B E D A A AA A AA A AA A AA A AA A AA A A 143' - 9 13/16" F F F F F F F F F F F F F F F CONTINUOUS RIDGE VENT FAS-1 GRD4" / 12"4" / 12"4" / 12"4 " / 1 2 " 4" / 12" 4 " / 1 2 "4" / 12"4 " / 1 2 "4" / 12"4 " / 1 2 " 4 " / 1 2 " 4" / 12" 4" / 12" G C100.1 FIRST FLOOR 100' - 0" THIRD FLOOR 122' - 4 5/8" TRUSS BEARING 131' - 4 7/8" SECOND FLOOR 111' - 2 3/4" 2 A-301 FCP-1 FCP-2 BRK ? ? STN FCB-1 FCB-1 STN ? ? ? STN ?FCP-1 ? ? ? STN RF ? TRM FAS-2 FAS-2 8 A-321 A A A A A A D E A A A A A A A A A A A A A A A A A AF F F F F F F F F F F F CONTINUOUS RIDGE VENT GC100.2 FAS-1 GRD4" / 12"4" / 12"4" / 12"4 " / 1 2 " 4 " / 1 2 "4" / 12"4 " / 1 2 " 4 " / 1 2 " FIRST FLOOR 100' - 0" THIRD FLOOR 122' - 4 5/8" TRUSS BEARING 131' - 4 7/8" SECOND FLOOR 111' - 2 3/4" FCP-1 FCP-2 BRK STN FCB-2 FCP-2 FCP-1 BRK FCB-1 RF FAS-2 FAS-2 TRM ? A A A A A A A A A A A A CONTINUOUS RIDGE VENT 4 " / 1 2 "4" / 12" 4 " / 1 2 " 4" / 12" 4 " / 1 2 "4" / 12"4" / 12"FIRST FLOOR 100' - 0" THIRD FLOOR 122' - 4 5/8" TRUSS BEARING 131' - 4 7/8" SECOND FLOOR 111' - 2 3/4" FAS-2FAS-2 ?TRM RF ? STN FCP-2 FCP-1 FCP-1 BRK BRK FCB-1 A A A C C C A B A CONTINUOUS RIDGE VENT 4 " / 1 2 "4" / 12" 4 " / 1 2 " 4" / 12" 4 " / 1 2 "4" / 12" F F F4" / 12"FCP-2 This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.Sheet No. Sheet Title Job No.Proj. Mgr.12/3/2021 5:51:55 AMJ:\2021\21113 Waukee Crossing Multi-Family - Hubbell\CAD-Arch\21113 Converge NW, Waukee, IA_60 Unit Apartment.rvt21113 SP EXTERIOR ELEVATIONS A-201CONVERGE NWAPARTMENTSWAUKEE, IAEXTERIOR MATERIAL LEGEND MAT. LABEL MATERIAL DESCRIPTION BRK MERIDIAN BRICK, THIN BRICK, COLOR - AMARO, NATURAL MORTAR (CLASS 2) DS PREFINISHED METAL DOWNSPOUT, COLOR - WHITE FAS-1 HARDIE FASCIA BOARD, SMOOTH, COLOR - ARCTIC WHITE FAS-2 PREFINISHED METAL FASCIA, COLOR - WHITE FCB-1 FIBER CEMENT LAP SIDING, SMOOTH, 6" REVEAL, COLOR - ARCTIC WHITE (CLASS 3) FCB-2 FIBER CEMENT LAP SIDING, SMOOTH, 6" REVEAL, COLOR - BOOTHBAY BLUE (CLASS 3) FCB-3 FIBER CEMENT LAP SIDING, SMOOTH, 6" REVEAL, COLOR - AGED PEWTER (CLASS 3) FCP-1 FIBER CEMENT PANEL SMOOTH SIDING, COLOR - COBBLESTONE (CLASS 3) FCP-2 FIBER CEMENT PANEL SMOOTH SIDING, COLOR - AGED PEWTER (CLASS 3) GUT PREFINISHED SEAMLESS GUTTERS (EXTRA DARK BRONZE) RF ARCHITECTURAL ASPHALT ROOFING SHINGLES, COLOR - CHARCOAL SF-1 T.B. ALUMINUM STOREFRONT FRAMING: CLEAR ANODIZED FINISH STN CENTURION STONE, COASTAL OHIO LIMESTONE (CLASS 2) TRM 5/4 HARDIE TRIM BOARD, SMOOTH, COLORPLUS, COLOR - ARCTIC WHITE VIS INSULATED VISION GLASS: CLEAR W/ LOW E COATING IN VINYL RESIDENTIALSTYLE WINDOW (CLASS 1) SCALE:1/8" = 1'-0"1 FRONT ELEVATION BOTH BUILDINGS SOUTH ELEVATION BUILDING #1 WEST ELEVATION BUILDING #2 SCALE:1/8" = 1'-0"2 SIDE ELEVATION 1 SCALE:1/8" = 1'-0"3 SIDE ELEVATION 2 Rev. #Issue / RevisionDate130% Set12-03-2021FRONT ELEVATION EXCLUDING OPENINGS: 7789 SF (TOTAL = 10,442 SF) STONE/BRICK = 2821 SF (36%>35%) FIBER CEMENT PANEL & BOARD: 4968 SF SIDE ELEVATION 1 EXCLUDING OPENINGS: 1808 SF (TOTAL = 2210 SF) STONE/BRICK = 706 SF (39%>35%) FIBER CEMENT PANEL & BOARD: 1102 SF EXTERIOR MATERIAL CALCULATIONS: SIDE ELEVATION 2 EXCLUDING OPENINGS: 1933 SF (TOTAL = 2267 SF) STONE/BRICK = 729 SF (38% >35%) FIBER CEMENT PANEL & BOARD: 1204 SF FIRST FLOOR 100' - 0" THIRD FLOOR 122' - 4 5/8" TRUSS BEARING 131' - 4 7/8" SECOND FLOOR 111' - 2 3/4" 2 A-301 ? TRM FAS-2FAS-2 RF ? STN FCP-1FCP-1 ? STN ? ? STN ? ? FCP-2 FCP-1 BRK ???? 8 A-321 A A A A A A A A A A A AA A A A A A A A AA A A A A AF F F F F F F F F F F F F F F CONTINUOUS RIDGE VENT 4" / 12"4" / 12"4 " / 1 2 "4" / 12"4 " / 1 2 "4" / 12" 4" / 12" 4 " / 1 2 "4" / 12"FAS-1GRD FIRST FLOOR 100' - 0" THIRD FLOOR 122' - 4 5/8" TRUSS BEARING 131' - 4 7/8" SECOND FLOOR 111' - 2 3/4" ? RF ?? STN STN STN ? FCP-1FCP-1 ? ???FCP-1 FCP-2 FCP-1 BRK ? TRM FAS-2 FAS-2 ? 1 A-301 A A A C C C A A A A A A A A A A A A A A A A A AA A A F F F F F F F F F F F F F F F CONTINUOUS RIDGE VENT 4" / 12"4" / 12"4 " / 1 2 " 4 " / 1 2 "4" / 12"4 " / 1 2 "4" / 12"4 " / 1 2 "4" / 12"FAS-1 GRD TYPICAL U.O.N. • EXPOSED CONCRETE: GRIND SMOOTH & RUB/COAT WITH CEMENT SLURRY. • METAL RAILINGS: GALVANIZED & PAINTED TO MATCH ADJACENT MATERIAL. • FASCIA & SOFFIT: METAL PREFINISHED TO MATCH ADJACENT ROOF COLOR. • SCUPPERS, GUTTERS & DOWNSPOUTS: METAL PREFINISHED TO MATCH ADJ. MATERIAL. • CAULKS & SEALANTS: COLOR MATCHED TO ADJACENT MATERIAL. • HOLLOW METAL MAN DOORS & FRAMES: PAINTED TO MATCH ADJACENT MATERIAL. • OVERHEAD PANEL DOORS: METAL PRE-FINISHED WHITE. • LOUVERS: METAL PRE-FINISHED TO MATCH ADJACENT MATERIAL COLOR. • LIGHT FIXTURES: METAL PRE-FINISHED HOUSINGS TO MATCH ADJ. OPENING FRAMING. • MECHANICAL EQUIPMENT: IF NOT SCREENED, COLOR TO MATCH ADJACENT MATERIAL. • EXTERIOR UTILITY EQUIPMENT: IF ALLOWED, PAINTED TO MATCH ADJACENT MATERIAL. • TRIM SIZES, TYP. U.O.N.: WINDOWS & DOORS 3-1/2” VERTICAL 3-1/2” HORIZONTAL 5-1/2” MISC EXTERIOR MATERIAL FINISHES This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.Sheet No. Sheet Title Job No.Proj. Mgr.12/3/2021 5:51:57 AMJ:\2021\21113 Waukee Crossing Multi-Family - Hubbell\CAD-Arch\21113 Converge NW, Waukee, IA_60 Unit Apartment.rvt21113 SP EXTERIOR ELEVATIONS A-202CONVERGE NWAPARTMENTSWAUKEE, IASCALE:1/8" = 1'-0"3 REAR ELEVATION BOTH BUILDINGS Rev. #Issue / RevisionDate130% Set12-03-2021REAR ELEVATION: 7,795 SF EXCLUDING GLAZING (TOTAL = 10,429 SF) STONE/BRICK = 2738 SF (35%) FIBER CEMENT PANEL & BOARD: 5057 SF EXTERIOR MATERIAL CALCULATIONS: EXTERIOR MATERIAL LEGEND MAT. LABEL MATERIAL DESCRIPTION BRK MERIDIAN BRICK, THIN BRICK, COLOR - AMARO, NATURAL MORTAR (CLASS 2) DS PREFINISHED METAL DOWNSPOUT, COLOR - WHITE FAS-1 HARDIE FASCIA BOARD, SMOOTH, COLOR - ARCTIC WHITE FAS-2 PREFINISHED METAL FASCIA, COLOR - WHITE FCB-1 FIBER CEMENT LAP SIDING, SMOOTH, 6" REVEAL, COLOR - ARCTIC WHITE (CLASS 3) FCB-2 FIBER CEMENT LAP SIDING, SMOOTH, 6" REVEAL, COLOR - BOOTHBAY BLUE (CLASS 3) FCB-3 FIBER CEMENT LAP SIDING, SMOOTH, 6" REVEAL, COLOR - AGED PEWTER (CLASS 3) FCP-1 FIBER CEMENT PANEL SMOOTH SIDING, COLOR - COBBLESTONE (CLASS 3) FCP-2 FIBER CEMENT PANEL SMOOTH SIDING, COLOR - AGED PEWTER (CLASS 3) GUT PREFINISHED SEAMLESS GUTTERS (EXTRA DARK BRONZE) RF ARCHITECTURAL ASPHALT ROOFING SHINGLES, COLOR - CHARCOAL SF-1 T.B. ALUMINUM STOREFRONT FRAMING: CLEAR ANODIZED FINISH STN CENTURION STONE, COASTAL OHIO LIMESTONE (CLASS 2) TRM 5/4 HARDIE TRIM BOARD, SMOOTH, COLORPLUS, COLOR - ARCTIC WHITE VIS INSULATED VISION GLASS: CLEAR W/ LOW E COATING IN VINYL RESIDENTIALSTYLE WINDOW (CLASS 1) WDWHFRIG. DW FURN.W WH FURN. D FRIG. DW 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL FURNITURE, FIXTURES AND EQUIPMENT SHOWN SHOULD BE CONSIDERED CONCEPTUAL AND MAY HAVE BE PROVIDED FOR COORDINATION PURPOSES ONLY. REFER TO FIRE SUPPRESSION, PLUMBING, MECHANICAL, ELECTRICAL, COMMUNICATIONS, ELECTRONIC SAFETY & SECURITY DOCUMENTS &/OR CONSULTANTS FOR SPECIFIC DESIGN INFORMATION & REQUIREMENTS. 3. DIMENSIONS ARE TO FACE OF FINISH MATERIAL AND CENTER OF DOOR UNLESS OTHERWISE SPECIFIED. 4. ALL CONDUITS, PIPES, WIRING, ROUGH-IN, ETC. SHOULD BE HELD AS TIGHT AS POSSIBLE TO THE ROOF OR FLOOR DECK OR SHOULD BE KEPT WITHIN INTERIOR WALL AND FLOOR/CEILING CAVITIES. NOTHING SHALL BE EXPOSED IN FINISHED SPACES, NOTHING SHALL PREVENT A SMOOTH CONTINUOUS FINISHED WALL OR CEILING AS NOTED ON THE DRAWINGS AND NO PLUMBING RAN IN EXTERIOR WALLS UNLESS PRIOR APPROVAL IS GRANTED BY THE ARCHITECT OR OWNER. PLACEMENT COORDINATION BETWEEN TRADES IS REQUIRED. 5. INSTALL AN EXHAUST FAN IN EACH BATHROOM AS REQUIRED BY CODE. EXTEND EXHAUST TO OUTSIDE AIR CODE REQUIREMENTS. 6. AT ALL UNITS WHERE THE WASHER & DRYER ARE LOCATED IN A DEDICATED CLOSET, PROVIDE A RETURN AIR GRILL IN THE WALL ABOVE THE DOOR HEADER SIZED TO PROVIDE ADEQUATE VENTILATION FOR PROPER WASHER & DRYER OPERATION. CONTRACTOR TO VERIFY COMPLIANCE OF DRYER VENT DISTANCE. 7. KITCHEN CABINETRY LAYOUTS ARE CONCEPTUAL ONLY. VERIFY FINAL LAYOUTS WITH OWNER PRIOR TO CONSTRUCTION. 8. PROVIDE ADEQUATE WOOD BLOCKING FOR MILLWORK, FIXTURES, EQUIPMENT, PLUMBING FIXTURES AND ACCESSORIES, ELECTRIC PANELS, FUTURE REQUIREMENTS, ETC. 9. ALL APARTMENTS ARE ANSI A-117 CH.10 TYPE B UNITS UNLESS OTHERWISE INDICATED. 10. REFER TO ACCESSIBILITY MATRIX FOR ACCESSIBLE, TYPE A, TYPE B, TYPE C & ACCESSIBLE COMMUNICATION UNIT REQUIREMENTS. GENERAL UNIT PLAN NOTES 4 1/2"7' - 0"4 1/2"3' - 0"4 1/2"5' - 8 1/2"7' - 11 1/2" 4 1/2" 5' - 2" 4 1/2" 11' - 1 1/2"3' - 0"4 1/2"5' - 8 1/2"12' - 1 1/8"4 1/2"9' - 2 1/2"2' - 0"5' - 0"10' - 8 1/2" 4 1/2" 13' - 11" 5' - 4 1/2" 4 1/2" 5" 6 1/2" 2' - 0" 4 1/2" 7' - 7 3/4" 8' - 3 1/4" BEDROOM 005 LIVING 004 DINING 003 BATHROOM 001 LAUNDRY 009 MECH. 008 CLOSET 006 COAT 007 KITCHEN 002 001009 007 008 006 005 A-411 4 5 A-411 6 25' - 0"28' - 8 1/8"E EE E E D F E E E F F E 13 10 1 2 3 5 7 9 3 4 11 5 8 4" MIN. 1' - 6"1' - 0"10' - 8 5/8"6 1/2"2' - 10"6' - 10"6 1/2"5' - 9"4 1/2"1' - 8 3/4"5' - 0"11' - 7 3/4"4 1/2"14' - 1 5/8"4 1/2"8' - 9 1/2"4' - 0" 3' - 4" 4 1/2" 7' - 2" 4 1/2" 11' - 10" 6' - 10" 4 1/2" 2' - 11" 7' - 11" KITCHEN 001 LIVING 002 BATH 005 MECH 006 BEDROOM 003 LAUNDRY 004 005 006 003 004 A-411 3 7 A-41182' - 10"E D FF G E D E E E E 8 1 2 3 1 2 3 1 2 3 11 5 10 9 3 4 6 7' - 8 5/8"3' - 0"12A 13 1 2 3 2"MIN.1' - 6"OUTLINE OF WALL @ FIRST LEVEL 1" 1' - 6" 2' - 6" 2' - 6" 3' - 0" 1" 1' - 9" 1' - 9"3' - 1"2' - 6"2' - 6"1' - 6" 1"3' - 0"1' - 6"2' - 6"7' - 0"11' - 5"3' - 0"1' - 9"3' - 0"2' - 0"1' - 6" 8' - 3"3' - 4"4"2' - 9"7' - 0"2' - 0" 3' - 0" 1' - 8 1/2" 1' - 7" 4" 2' - 6" 5' - 0" 2' - 0" 1" 3' - 0"2' - 6"2' - 6" 2' - 0"3' - 1"2' - 6"2' - 6"3' - 0"4"1' - 2"2' - 6"7' - 0"12' - 7" 2"2' - 0"3' - 0"1' - 6"1' - 3"3' - 0"1' - 0" 3' - 0" 1' - 5" 1' - 5" 2" 2' - 8" 9' - 8"4"2' - 9"3' - 4"12" 12"33"-36"24" 12"33"-36"24" GRAB BAR 36" GRAB BAR MIN. 15 3/4" MIN. 15 3/4"12" 42" MIN.33"-36"SWING UP GRAB BAR SIDE GRAB BAR12" MIN.NOTE: ALL GRAB BAR BLOCKING SHALL BE MIN 2X8 WOOD BLOCKING TO ENSURE ADEQUATE COVERAGE FOR MIN 6" BLOCKING REQUIREMENTS. ALL BLOCKING TO BE VERTICALLY CENTERED ON GRAB BAR.33"-36"SHOWER SHOWER-CONTROL WALL TUB- BACK WALLTUB- CONTROL WALL TUB- HEAD END WALL INSTALL BLOCKING FOR FUTURE GRAB BARS INSTALL BLOCKING FOR FUTURE GRAB BARS INSTALL BLOCKING FOR FUTURE GRAB BARS INSTALL BLOCKING FOR FUTURE GRAB BARS INSTALL BLOCKING FOR CONTROLS INSTALL BLOCKING FOR CONTROLS T.O. BAR33"-36"MAX.32"MIN.6"12- 24"MAX.32"33- 36"3" -6"MIN.18"8" -10"T.O. BAR33"-36"MIN. 24"12" MAX 24" MIN.24" MAX MAX6"T.O. BAR33"-36"24" 6" MAX MAX.32"6" MIN.T.O. BAR33"-36"T.O. BAR33"-36"6" MIN.32"MAX. 27" MIN. 16"MAX48"4" MAX. CL 4" MAX. 6" MAX. NOTE: ALL GRAB BAR BLOCKING SHALL BE MIN 2X8 WOOD BLOCKING TO ENSURE ADEQUATE COVERAGE FOR MIN 6" BLOCKING REQUIREMENTS. ALL BLOCKING TO BE VERTICALLY CENTERED ON GRAB BAR.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.Sheet No. Sheet Title Job No.Proj. Mgr.12/3/2021 5:51:58 AMJ:\2021\21113 Waukee Crossing Multi-Family - Hubbell\CAD-Arch\21113 Converge NW, Waukee, IA_60 Unit Apartment.rvt21113 SP UNIT PLANS A-411CONVERGE NWAPARTMENTSWAUKEE, IASCALE:1/4" = 1'-0"1 UNIT 1A SCALE:1/4" = 1'-0"2 UNIT 1B SCALE:1/2" = 1'-0"4 UNIT 1A - KITCHEN ELEVATION SCALE:1/2" = 1'-0"5 UNIT 1A - KITCHEN ELEVATION SCALE:1/2" = 1'-0"6 UNIT 1A - BATH ELEVATION UNIT 1A DOOR & FRAME SCHEDULE DOOR NO. ROOM NAME DOOR FRAME REMARKS (ALSO SEE NOTES) UNITTYPE PAIR WIDTH HEIGHT MAT'L TYPE MAT'L 001 BATHROOM No 3' - 0" 6' - 8" WOOD WOOD PRIVACY LOCK 1A 005 BEDROOM No 3' - 0" 6' - 8" WOOD WOOD PRIVACY LOCK 1A 006 CLOSET No 3' - 0" 6' - 8" WOOD WOOD PASSAGE 1A 007 COAT No 2' - 10" 6' - 8" WOOD WOOD PASSAGE 1A 008 MECH. Yes 5' - 0" 6' - 8" WOOD WOOD SLIDING BI-PASS 1A 009 LAUNDRY No 3' - 0" 6' - 8" WOOD WOOD PASSAGE 1A UNIT 1B DOOR & FRAME SCHEDULE DOOR NO.ROOM NAME DOOR FRAME REMARKS (ALSO SEE NOTES)UNITTYPE PAIR WIDTH HEIGHT MAT'L TYPE MAT'L 003 BEDROOM No 3' - 0" 6' - 8" WOOD WOOD PRIVACY LOCK 1B 004 LAUNDRY No 3' - 0" 6' - 8" WOOD WOOD PASSAGE 1B 005 BATH No 3' - 0" 6' - 8" WOOD WOOD PRIVACY LOCK 1B 006 MECH Yes 5' - 0" 6' - 8" WOOD WOOD PASSAGE 1B SCALE:1/2" = 1'-0"3 UNIT 1B - KITCHEN ELEVATION SCALE:1/2" = 1'-0"7 UNIT 1B - KITCHEN ELEVATION SCALE:1/2" = 1'-0"8 UNIT 1B - BATH ELEVATION Rev. #Issue / RevisionDate130% Set12-03-2021P2 P2 P2 P2 P2 P2 B B B B B B P2 P2 P2 P2 B B B B SCALE:1/4" = 1'-0"9 TOILET GRAB BARS SCALE:1/4" = 1'-0"10 SHOWER / TUB GRAB BARS UNIT PLAN KEYNOTES LABEL REMARKS 1 REFER TO OVERALL BUILDING PLANS FOR SPECIFIC WINDOW TYPE & LOCATION, TYP. 2 WINDOWS TO RECEIVE DRYWALL SILL & RETURNS TO MATCH ADJ. WALL, TYP. 3 INSTALL WINDOW BLINDS, SIZED TO FIT WINDOW, AT ALL WINDOW LOCATIONS; SPECIFIC T.B.D., TYP. 4 REFER TO OVERALL BUILDING PLANS FOR DECK/PATIO SIZE, DETAILS, ETC. 5 COATED WIRE SHELF W/ INTEGRAL HANGING ROD - 12" DEEP 6 (5 LAYERS) COATED WIRE SHELF - 16" DEEP; TOP OF 3 LAYERS TO BE INSTALLED BETWEEN 15"-48" AFF 6A (5 LAYERS) WHITE PAINTED MILLWORK SHELF - 16" DEEP; TOP OF 3 LAYERS TO BE INSTALLED BETWEEN 15"-48" AFF 6B (3 LAYERS) WHITE PAINTED MILLWORK SHELF - 16" DEEP; TOP OF 2 LAYERS TO BE INSTALLED BETWEEN 15"-48" AFF 7 (2 LAYERS) COATED WIRE SHELF WITH INTEGRAL HANGING ROD - 12" DEEP; TOP OF LOWER SHELF AND ROD TO BE INSTALLED AT 48" AFF MAX. 8 UNIT ENTRY DOOR; REFER TO DETAIL #3 ON SHEET G-011 FOR MINIMUM DOOR CLEARANCES 9 REFER TO OVERALL BUILDING PLANS FOR SPECIFIC PATIO DOOR LOCATION 10 MECHANICAL EQUIPMENT SHOWN FOR COORDINATION PURPOSES ONLY; ALL MEP SCOPE IS DESIGN-BUILD BY CONTRACTOR 11 STEEL COUNTERTOP BRACKET - SIZED APPROPRIATELY PER OVERHANG, TYP. 12A COAT HOOKS INSTALLED @ 66" AFF (TYPE A UNTIS @ 46" AFF) OVER STAINED WOOD RAIL. STAINED WOOD BENCH BELOW UP TO 18" AFF. 12B COAT HOOKS INSTALLED @ 66" AFF (TYPE A UNTIS @ 46" AFF) OVER STAINED WOOD RAIL. 13 ELECTRICAL PANEL - FOR COORDINATION ONLY; ALL MEP SCOPE IS DESIGN-BUILD BY CONTRACTOR 14 36" X80" CASED OPENING TYPE A UNITS: COMMON BATHROOM TOILETS - INSTALL BLOCKING FOR 36" REAR WALL GRAB BAR AND 42" SIDE WALL GRAB BAR MASTER BATHROOM TOILETS - WHERE SPACE ALLOWS, INSTALL BLOCKING FOR 36" REAR WALL GRAB BAR AND 42" SIDE WALL GRAB BAR - WHERE SPACE WILL NOT PERMIT THE 36" REAR WALL GRAB BAR, IONSTALL BLOCKING FOR THE 24" GRAB BAR - WHERE SPACE WILL NTO PERMIT THE 42" SIDE WALL GRAB BAR, INSTALL BLOACKING FOR TWO SWING-UP GRAB BARS TYPE B UNITS: ALL BATHROOM TOILETS - WHERE SPACE ALLOWS, INSTALL BLOCKING FOR 36" REAR WALL GRAB BAR AND 42" SIDE WALL GRAB BAR - WHERE SPACE WILL NOT PERMIT THE 36" REAR WALL GRAB BAR, IONSTALL BLOCKING FOR THE 24" GRAB BAR - WHERE SPACE WILL NTO PERMIT THE 42" SIDE WALL GRAB BAR, INSTALL BLOACKING FOR TWO SWING-UP GRAB BARS FRIG. DW W D WHFURN. FRIG. DW WHFURN.WD18" MIN. 1' - 6" 2' - 10" 4 1/2" 5' - 9 3/4" 4 1/2" 1' - 3" 4 1/2" 15' - 3" 4 1/2" 8' - 6 1/4"1' - 0"11' - 0"4 1/2"2' - 0"4 1/2"6' - 8"6 1/2"7' - 8 5/8"10' - 11 3/4" 4 1/2" 12' - 4 3/4" 4 1/2" 11' - 4 1/2"8' - 3"4 1/2"7' - 6"4 1/2"35' - 6"28' - 8 1/8"10' - 11 3/4" 4 1/2" 12' - 4 3/4" 4 1/2" 5' - 0" 6 1/2" 5' - 6"4" 10' - 11 3/4" 4 1/2" 3' - 4 3/4" 9' - 0" 4 1/2" 2' - 5 3/4" 4 1/2" 2' - 9 1/4" 3' - 0" 2' - 9"2' - 4"5' - 4 5/8"M. BEDROOM 008 BEDROOM 2 005 BATH 004 M. CLOSET 010 M. BATHROOM 009 CLOSET 006 MECH. 003 LAUNDRY 002 KITCHEN 001 LIVING 007 002 004 005 008 003 006 A-412 3 5 4 A-412 6 E E E D E G E E E E E E E E E 1' - 5"18" MIN.1' - 7"13 10 7 7 6 5 1 2 3 1 2 3 11 9 3 4 5 12A 18" MIN.1' - 10"14 4" 8 A-412 7 D 009 G OUTLINE OF WALL @ FIRST LEVEL 11' - 7 1/8"4 1/2"5' - 0"4 1/2"11' - 4"28' - 8 1/8"4" 5' - 0" 6 1/2" 5' - 3 1/16" 1' - 4" 4 1/2" 11' - 1" 4 1/2" 5' - 0" 4 1/2" 3' - 0" 5' - 0"6 1/2"6' - 10 1/4" 8' - 10" 4 1/2"4' - 11 7/8" 4 1/2" 2' - 0" 4 1/2" 6' - 2" 10' - 10 1/2" 4 1/2" 12' - 6 3/4" 4 1/2" 12' - 3 3/4" 10' - 10 1/2" 4 1/2" 9' - 11 5/8" 4 1/2" 6' - 7 3/4" 6 1/2" 6' - 8 5/8" 1' - 0"5' - 0 7/8"4 1/2"3' - 0"6 1/2"4' - 7 1/2"4 1/2"3' - 0"1' - 0"11' - 3 3/4"0"4 1/2"11' - 5 3/8"6 1/2"5' - 0"29' - 8 1/8"BEDROOM 2 004 M. BEDROOM 006 CLOSET 003 BATHROOM 002 KITCHEN 001 LIVING 005 LAUNDRY 007 MECH 008 CLOSET 011 LIN. 009 M. BATH 010 002 003 004 006 010 007 008 A-41211 A-412 9 8 10 A-412 12 D E E E E E D E D E E E D G 14 11 10 7 6 5 6A 5 7 2' - 1" 1 2 3 9 3 4 1 2 3 1 2 3 1 2 3 13 8 12A 4" 18" MIN. 1' - 7" OUTLINE OF WALL @ FIRST LEVEL 2' - 0" 1" 3' - 0"2' - 0"1' - 0"1' - 0"1' - 0"3' - 0"4"1' - 2"2' - 6"7' - 0"2' - 0"3' - 1"2' - 0"1' - 0"2' - 0" 10' - 1" 2' - 1 1/4" 2' - 6" 3" 2' - 6" 1' - 0" 2' - 0"2' - 10"2' - 9" 2' - 6" 1' - 0" 1' - 0" 1' - 0"2' - 6"1' - 2"4"3' - 0"8' - 3" 8' - 3" MICROWAVE BASE WITH DRAWER @ UNIT 114 ONLY. ALL OTHER UNITS TO RECEIVE STANDARD 33" DOUBLE DOOR, DOUBLE DRAWER BASE. HOOD AT RANGE @ UNIT 114 ONLY . VERIFY CONTROL SWITCH WITHIN REACH RANGE ON BACK WALL. ALL OTHER UNITS TO RECEIVE MICROWAVE ABOVE RANGE ACCESSIBLE RANGE @ UNIT 114 ONLY. VERIFY CONTROLS ARE AT FRONT OF UNIT. 1' - 6" 2' - 0" 3' - 0" 2' - 6"MAX.2' - 10"9' - 0"2' - 6"4' - 6"7' - 0"REMOVEABLE SINK BASE @ UNIT 114 ONLY. VERIFY FINISH FLOOR TO EXTEND UNDER CABINET REMOVEABLE BASE FOR WORKSTATION @ UNIT 114 ONLY. ALL OTHER UNITS TO RECIEVE STANDARD 30" CABINET. VERIFY FINISH FLOOR TO EXTEND UNDER CABINET 2' - 9"4"3' - 4"1' - 0"3' - 0"1' - 0" 5' - 0" 16"-18" 2' - 3" 3' - 1" 2' - 9" 1' - 0" 2' - 0" 1' - 0"1' - 0"1' - 0"2' - 9"3' - 0" 1" 2' - 3" 11' - 1"2' - 6"1' - 2"4"3' - 0"7' - 0"2' - 0" 1' - 0" 2' - 6" 2' - 6" 1" 2' - 0" 1' - 0" 1' - 0" 1' - 0" 2' - 6" 2' - 6" FILLER 0" 8' - 0"2' - 6"1' - 2"4"3' - 0"3' - 0"E 2' - 0" 4 3/8"FILLER 1" 3' - 6" 3' - 0" 2' - 0" 3"3' - 0"4"1' - 2"2' - 6"7' - 0"3' - 0"2' - 6" 1' - 7" 1' - 6 1/8" 4' - 0" 2' - 0"4"2' - 9"7' - 0"MAX.3' - 4"5' - 0" 6 1/2" 1' - 11" 2' - 0 3/8" 3' - 0" 1' - 6" 3' - 0"MAX.3' - 4"4"2' - 9"7' - 6" 3' - 3" 1' - 0" 3' - 3" 7' - 6"4"2' - 9"3' - 4"This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.Sheet No. Sheet Title Job No.Proj. Mgr.12/3/2021 5:51:59 AMJ:\2021\21113 Waukee Crossing Multi-Family - Hubbell\CAD-Arch\21113 Converge NW, Waukee, IA_60 Unit Apartment.rvt21113 SP UNIT PLANS A-412CONVERGE NWAPARTMENTSWAUKEE, IASCALE:1/4" = 1'-0"1 UNIT 2A - TYPE A @ UNIT 114 SCALE:1/4" = 1'-0"2 UNIT 2B UNIT 2A DOOR & FRAME SCHEDULE DOOR NO.ROOM NAME DOOR FRAME REMARKS (ALSO SEE NOTES)UNITTYPE PAIR WIDTH HEIGHT MAT'L TYPE MAT'L 002 LAUNDRY No 3' - 0" 6' - 8" WOOD WOOD PASSAGE 2A 003 MECH. Yes 5' - 0" 6' - 8" WOOD WOOD PASSAGE 2A 004 BATH No 3' - 0" 6' - 8" WOOD WOOD PRIVACY LOCK 2A 005 BEDROOM 2 No 3' - 0" 6' - 8" WOOD WOOD PRIVACY LOCK 2A 006 CLOSET Yes 5' - 0" 6' - 8" WOOD WOOD PASSAGE 2A 008 M. BEDROOM No 3' - 0" 6' - 8" WOOD WOOD PRIVACY LOCK 2A 009 M. BEDROOM No 2' - 10" 6' - 8" WOOD WOOD PRIVACY LOCK 2A SCALE:1/2" = 1'-0"3 UNIT 2A - KITCHEN ELEVATION SCALE:1/2" = 1'-0"4 UNIT 2A - KITCHEN ELEVATION SCALE:1/2" = 1'-0"5 UNIT 2A - KITCHEN ELEVATION SCALE:1/2" = 1'-0"6 UNIT 2A - BATH ELEVATION SCALE:1/2" = 1'-0"8 UNIT 2B - KITCHEN ELEVATION SCALE:1/2" = 1'-0"9 UNIT 2B - KITCHEN ELEVATION SCALE:1/2" = 1'-0"10 UNIT 2B - KITCHEN ELEVATION SCALE:1/2" = 1'-0"11 UNIT 2B - BATH ELEVATION SCALE:1/2" = 1'-0"12 UNIT 2B - M. BATH ELEVATION UNIT 2B DOOR & FRAME SCHEDULE DOOR NO. ROOM NAME DOOR FRAME REMARKS (ALSO SEE NOTES) UNITTYPE PAIR WIDTH HEIGHT MAT'L TYPE MAT'L 002 BATHROOM No 3' - 0" 6' - 8" WOOD WOOD PRIVACY LOCK 2B 003 CLOSET No 2' - 8" 6' - 8" WOOD WOOD PASSAGE 2B 004 BEDROOM 2 No 3' - 0" 6' - 8" WOOD WOOD PRIVACY LOCK 2B 006 M. BEDROOM No 3' - 0" 6' - 8" WOOD WOOD PRIVACY LOCK 2B 007 LAUNDRY No 3' - 0" 6' - 8" WOOD WOOD PASSAGE 2B 008 MECH Yes 4' - 0" 6' - 8" WOOD WOOD PASSAGE 2B 010 LIN. No 2' - 10" 6' - 8" WOOD WOOD PRIVACY LOCK 2B Rev. #Issue / RevisionDate130% Set12-03-2021P2 P2 P2 P2 P2 P2 B B B B B B P2 B UNIT PLAN KEYNOTES LABEL REMARKS 1 REFER TO OVERALL BUILDING PLANS FOR SPECIFIC WINDOW TYPE & LOCATION, TYP. 2 WINDOWS TO RECEIVE DRYWALL SILL & RETURNS TO MATCH ADJ. WALL, TYP. 3 INSTALL WINDOW BLINDS, SIZED TO FIT WINDOW, AT ALL WINDOW LOCATIONS; SPECIFIC T.B.D., TYP. 4 REFER TO OVERALL BUILDING PLANS FOR DECK/PATIO SIZE, DETAILS, ETC. 5 COATED WIRE SHELF W/ INTEGRAL HANGING ROD - 12" DEEP 6 (5 LAYERS) COATED WIRE SHELF - 16" DEEP; TOP OF 3 LAYERS TO BE INSTALLED BETWEEN 15"-48" AFF 6A (5 LAYERS) WHITE PAINTED MILLWORK SHELF - 16" DEEP; TOP OF 3 LAYERS TO BE INSTALLED BETWEEN 15"-48" AFF 6B (3 LAYERS) WHITE PAINTED MILLWORK SHELF - 16" DEEP; TOP OF 2 LAYERS TO BE INSTALLED BETWEEN 15"-48" AFF 7 (2 LAYERS) COATED WIRE SHELF WITH INTEGRAL HANGING ROD - 12" DEEP; TOP OF LOWER SHELF AND ROD TO BE INSTALLED AT 48" AFF MAX. 8 UNIT ENTRY DOOR; REFER TO DETAIL #3 ON SHEET G-011 FOR MINIMUM DOOR CLEARANCES 9 REFER TO OVERALL BUILDING PLANS FOR SPECIFIC PATIO DOOR LOCATION 10 MECHANICAL EQUIPMENT SHOWN FOR COORDINATION PURPOSES ONLY; ALL MEP SCOPE IS DESIGN-BUILD BY CONTRACTOR 11 STEEL COUNTERTOP BRACKET - SIZED APPROPRIATELY PER OVERHANG, TYP. 12A COAT HOOKS INSTALLED @ 66" AFF (TYPE A UNTIS @ 46" AFF) OVER STAINED WOOD RAIL. STAINED WOOD BENCH BELOW UP TO 18" AFF. 12B COAT HOOKS INSTALLED @ 66" AFF (TYPE A UNTIS @ 46" AFF) OVER STAINED WOOD RAIL. 13 ELECTRICAL PANEL - FOR COORDINATION ONLY; ALL MEP SCOPE IS DESIGN-BUILD BY CONTRACTOR 14 36" X80" CASED OPENING P2 P2 P2 P2 P2 P2 B B B B B B P2 B SCALE:1/2" = 1'-0"7 UNIT 2A - M. BATH ELEVATION DWFRIG.DWWH FURN.10' - 5 7/8"4 1/2"2' - 4 1/2"6 1/2"7' - 1 3/8"4 1/2"10' - 2 3/4"1' - 0"32' - 6"5' - 9"4 1/2"11' - 2 7/8"3' - 6 3/8"4 1/2"2' - 0"4 1/2"7' - 10 1/4"1' - 0" 10' - 2 3/4" 2' - 11 1/2" 4 1/2" 3' - 0" 4 1/2" 16' - 0 1/2" 4 1/2" 11' - 3" 4"2' - 9 7/8"5' - 6"4 1/2"3' - 5 1/2"6 1/2"5' - 0"4 1/2"13' - 5 1/8"4 1/2" 2' - 0" 6 1/2" 9' - 10 1/2" 4 1/2" 3' - 0 1/4" 6 1/2" 5' - 4" 4 1/2" 9' - 6" 4" 6" 4" 2' - 0" 4 1/2" 4' - 5 1/2" 4 1/2" 9' - 2 1/2" 4 1/2" 12' - 1 1/4" 4 1/2" 3' - 2" 6' - 8"7' - 7"3' - 6 1/2"BEDROOM 3 005 LIN. 007 BATH 008 KITCHEN 002 LIVING 012 ENTRY 001 BEDROOM 2 009 CLOSET 010 PANTRY 011 M. BEDROOM 013 M. BATH 014 M. CLOSET 015 MECH. 004 LAUNDRY 003 CLOSET 006 009 011 010 008 007 005 006 003 004 013 014 A-4132 3 A-413 4 A-413 5 E E D E E F D E E E E E E E E D E D 8 12B 10 11 9 3 4 1 2 3 1 2 3 1 2 3 1 2 3 5 5 6B 5 6 6 7 14 13 4" 18" MIN. 1' - 8" 2' - 0" OUTLINE OF WALL @ FIRST LEVEL 1' - 9" 2' - 6" 3" 2' - 6" 3' - 1" 1' - 9" 2' - 6" 2' - 9" 3' - 0" 1"3' - 0"4"1' - 2"2' - 6"HOOD AT RANGE @ UNIT 101 ONLY. VERIFY CONTROL SWITCH WITHIN REACH RANGE ON BACK WALL. ALL OTHER UNITS TO RECEIVE MICROWAVE ABOVE RANGE ACCESSIBLE RANGE @ UNIT 101 ONLY. VERIFY CONTROLS ARE AT FRONT OF UNIT. MICROWAVE BASE WITH DRAWER @ UNIT 101 ONLY. ALL OTHER UNITS TO RECEIVE STANDARD 30" DOUBLE DOOR, DOUBLE DRAWER BASE. 1" 2' - 0" 3' - 0" 2' - 6"MAX.2' - 10"7' - 7" REMOVEABLE SINK BASE @ UNIT 101 ONLY. VERIFY FINISH FLOOR TO EXTEND UNDER CABINET REMOVEABLE BASE FOR WORKSTATION @ UNIT 101 ONLY. ALL OTHER UNITS TO RECIEVE STANDARD 30" CABINET. VERIFY FINISH FLOOR TO EXTEND UNDER CABINET 1' - 5"2' - 5"3' - 0"1' - 0"2' - 10"4"3' - 4"4' - 0" 2' - 0" 3' - 0" 1' - 0" 3' - 0" 9' - 0"7' - 0"3' - 4"1' - 6"4"2' - 9"This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.Sheet No. Sheet Title Job No.Proj. Mgr.12/3/2021 5:51:59 AMJ:\2021\21113 Waukee Crossing Multi-Family - Hubbell\CAD-Arch\21113 Converge NW, Waukee, IA_60 Unit Apartment.rvt21113 SP UNIT PLANS A-413CONVERGE NWAPARTMENTSWAUKEE, IASCALE:1/4" = 1'-0"1 UNIT 3A - TYPE A @ UNIT 101 SCALE:1/2" = 1'-0"2 UNIT 3A - KITCHEN ELEVATION SCALE:1/2" = 1'-0"3 UNIT 3A - KITCHEN ELEVATION SCALE:1/2" = 1'-0"4 UNIT 3A - BATH ELEVATION SCALE:1/2" = 1'-0"5 UNIT 3A - M. BATH ELEVATION UNIT 3A DOOR & FRAME SCHEDULE DOOR NO.ROOM NAME DOOR FRAME REMARKS (ALSO SEE NOTES)UNITTYPE PAIR WIDTH HEIGHT MAT'L TYPE MAT'L 003 LAUNDRY No 3' - 0" 6' - 8" WOOD WOOD PASSAGE 3A 004 MECH. Yes 5' - 0" 6' - 8" WOOD WOOD PASSAGE 3A 005 BEDROOM 3 No 3' - 0" 6' - 8" WOOD WOOD PRIVACY LOCK 3A 006 CLOSET Yes 5' - 0" 6' - 8" WOOD WOOD PASSAGE 3A 007 LIN. No 2' - 0" 6' - 8" WOOD WOOD PASSAGE 3A 008 BATH No 3' - 0" 6' - 8" WOOD WOOD PRIVACY LOCK 3A 009 BEDROOM 2 No 3' - 0" 6' - 8" WOOD WOOD PRIVACY LOCK 3A 010 CLOSET Yes 6' - 4" 6' - 8" WOOD WOOD PASSAGE 3A 011 PANTRY No 2' - 10" 6' - 8" WOOD WOOD PASSAGE 3A 013 M. BEDROOM No 3' - 0" 6' - 8" WOOD WOOD PRIVACY LOCK 3A 014 M. BATH No 3' - 0" 6' - 8" WOOD WOOD PRIVACY LOCK 3A Rev. #Issue / RevisionDate130% Set12-03-2021P2 P2 P2 P2 P2 P2 B B B B B B P2 B P2 P2 P2 P2 B B B B UNIT PLAN KEYNOTES LABEL REMARKS 1 REFER TO OVERALL BUILDING PLANS FOR SPECIFIC WINDOW TYPE & LOCATION, TYP. 2 WINDOWS TO RECEIVE DRYWALL SILL & RETURNS TO MATCH ADJ. WALL, TYP. 3 INSTALL WINDOW BLINDS, SIZED TO FIT WINDOW, AT ALL WINDOW LOCATIONS; SPECIFIC T.B.D., TYP. 4 REFER TO OVERALL BUILDING PLANS FOR DECK/PATIO SIZE, DETAILS, ETC. 5 COATED WIRE SHELF W/ INTEGRAL HANGING ROD - 12" DEEP 6 (5 LAYERS) COATED WIRE SHELF - 16" DEEP; TOP OF 3 LAYERS TO BE INSTALLED BETWEEN 15"-48" AFF 6A (5 LAYERS) WHITE PAINTED MILLWORK SHELF - 16" DEEP; TOP OF 3 LAYERS TO BE INSTALLED BETWEEN 15"-48" AFF 6B (3 LAYERS) WHITE PAINTED MILLWORK SHELF - 16" DEEP; TOP OF 2 LAYERS TO BE INSTALLED BETWEEN 15"-48" AFF 7 (2 LAYERS) COATED WIRE SHELF WITH INTEGRAL HANGING ROD - 12" DEEP; TOP OF LOWER SHELF AND ROD TO BE INSTALLED AT 48" AFF MAX. 8 UNIT ENTRY DOOR; REFER TO DETAIL #3 ON SHEET G-011 FOR MINIMUM DOOR CLEARANCES 9 REFER TO OVERALL BUILDING PLANS FOR SPECIFIC PATIO DOOR LOCATION 10 MECHANICAL EQUIPMENT SHOWN FOR COORDINATION PURPOSES ONLY; ALL MEP SCOPE IS DESIGN-BUILD BY CONTRACTOR 11 STEEL COUNTERTOP BRACKET - SIZED APPROPRIATELY PER OVERHANG, TYP. 12A COAT HOOKS INSTALLED @ 66" AFF (TYPE A UNTIS @ 46" AFF) OVER STAINED WOOD RAIL. STAINED WOOD BENCH BELOW UP TO 18" AFF. 12B COAT HOOKS INSTALLED @ 66" AFF (TYPE A UNTIS @ 46" AFF) OVER STAINED WOOD RAIL. 13 ELECTRICAL PANEL - FOR COORDINATION ONLY; ALL MEP SCOPE IS DESIGN-BUILD BY CONTRACTOR 14 36" X80" CASED OPENING FINISHED FLOOR 0" TRUSS BEARING 10' - 1 1/8" FCB RF FCB STN FCB FCP STN STN VIS FINISHED FLOOR 0" TRUSS BEARING 10' - 1 1/8" POSTAL PACKAGE LOCKER. COORDINATE SIZE WITH POSTAL. FCB FCP BRK STN STN FAS FAS RF VIS FINISHED FLOOR 0" TRUSS BEARING 10' - 1 1/8" STN STN FCB FCB RF FINISHED FLOOR 0" TRUSS BEARING 10' - 1 1/8" FCP FCP FCP BRK BRK VIS SAA JOB #: This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C. 24"x36" SHEET (FULL SIZE) -SCALE IS AS NOTED. 12"x18" SHEET (HALF SIZE) -SCALE IS ONE-HALF OF WHAT IS NOTED OTHER SHEET SIZES NOT TO SCALE 21113 WAUKEE CROSSING CLUBHOUSE WAUKEE, IOWA 11/01/2021 EXTERIOR MATERIAL LEGEND MAT. LABEL MATERIAL DESCRIPTION BRK MERIDIAN THIN BRICK - AMARO; NATURAL MORTAR FAS PREFINISHED METAL FASCIA, COLOR - WHITE FCB FIBER CEMENT LAP SIDING, 6" REVEAL, COLOR - WHITE FCP FIBER CEMENT PANEL SMOOTH SIDING, COLOR - DARK GRAY FCT 5/4 HARDIE TRIM BOARD, SMOOTH, COLORPLUS, ARCTIC WHITE RF ARCHITECTURAL ASPHALT ROOFING SHINGLES, COLOR- CHARCOAL SF T.B. ALUMINUM STOREFRONT FRAMING: CLEAR ANODIZED FINISH STN MANUFACTURED VENEER STONE (INSTALLED PER MFR.) VIS 1” INSULATED VISION GLASS: CLEAR W/ LOW E COATING • H. METAL MAN DOORS & FRAMES: PAINTED TO MATCH ADJACENT MATERIAL. • GUTTERS AND DOWNSPOUTS: METAL PREFINISHED TO MATCH ADJACENT MATERIAL. • FASCIA AND SOFFIT: METAL PREFINISHED TO MATCH ROOF COLOR. • CAULKS AND SEALANTS: COLOR MATCHED TO ADJACENT MATERIAL. 3D VIEW SCALE:3/16" = 1'-0"1 NORTH ELEVATION SCALE:3/16" = 1'-0"2 WEST ELEVATION SCALE:3/16" = 1'-0"3 EAST ELEVATION SCALE:3/16" = 1'-0"4 SOUTH ELEVATION WH651 SF FITNESS 918 SF COMMUNITY 304 SF BUSINESS 107 SF BUSINESS 145 SF STORAGE 69 SF STORAGE 175 SF KITCHENETTE 1497 SF POOL 91 SF UTILITY 422 SF BUSINESS 4616 SF POOL DECK Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.NEW CONSTRUCTION FOR NOT FOR CONSTRUCTIONSAA J:\2021\21113 Waukee Crossing Multi-Family - Hubbell\CAD-Arch\21113 Converge NW, Waukee, IA_Clubhouse.rvt12/3/2021 11:20:36 AMCONVERGE NWCLUBHOUSEWAUKEE, IOWA21113 G-000 CONVERGE NW CLUBHOUSE WAUKEE, IOWA COVER SHEET SP Simonson & Associates Architects LLC and their consultants has completed these design documents to the level of detail requested by our client. The level of detail may range from schematic design document(s) mainly conveying programmatic information to fully detailed documents and specifications. However, the clients intent and expectations are that these documents be used as the basis for design for an complete all-inclusive project based upon industry standards & manufacturer recommendations for all disciplines & materials. It should also satisfy all authorities having jurisdiction requirements. IMPORTANT DESIGN SCOPE NOTE: 24"x36" SHEET (FULL SIZE) - SCALE IS AS NOTED. 12"x18" SHEET (HALF SIZE) - SCALE IS ONE-HALF OF WHAT IS NOTED OTHER SHEET SIZES NOT TO SCALE SCALE NOTE: - DOOR INDICATOR - FINISH INDICATOR - KEYNOTE - REVISION INDICATOR - ROOM INDICATOR - WALL / FLOOR / CEILING / ROOF ASSEMBLY TYPE IDENTIFIER - WINDOW INDICATOR LEGEND: - - - - - NOTE: THIS DRAWING DOES NOT REPRESENT AN AS-BUILT CONDITION. ACTUAL DETAILS AND DIMENSIONS MAY VARY AND ARE SUBJECT TO CHANGE. AS-BUILT CONDITIONS MUST BE FIELD VERIFIED PRIOR TO FINAL LAYOUT AND CONSTRUCTION OF INTERIOR TENANT IMPROVEMENTS. NOTE: ALL DESIGN DOCUMENTS ARE SUBJECT TO AUTHORITIES HAVING JURISDICTION REVIEW AND APPROVAL. - - ARCHITECTURAL G-000 COVER SHEET G-001 SPECIFICATION NOTES G-011 ACCESSIBILITY REQUIREMENTS & GUIDELINES A-101 FLOOR PLAN A-111 ROOF PLAN & REFLECTED CEILING PLAN A-201 EXTERIOR ELEVATIONS A-301 BUILDING SECTIONS A-311 WALL SECTIONS A-312 WALL SECTIONS A-401 ENLARGED PLANS & INTERIOR ELEVATIONS A-501 DETAILS DOCUMENTS BY OTHERS FIRE SUPPRESSION (Refer to these design documents under separate cover.) ELECTRONIC SAFETY & SECURITY (Refer to these design documents under separate cover.) CIVIL -LANDSCAPING (Refer to these design documents under separate cover.) GEOTECHNICAL INVESTIGATIONS (Refer to these condition documents under separate cover) PLUMBING (Refer to these design documents under separate cover.) SPECIFICATION MANUAL Not Provided - All Specification Notes included on drawings. INDEX OF DRAWINGS STRUCTURAL S-001 STRUCTURAL NOTES S-101 STRUCTURAL PLANS S-201 FOUNDATION DETAILS S-301 FRAMING DETAILS ENERGY Refer to COMcheck Compliance Certificates. COMMUNICATIONS (Refer to these design documents under separate cover.) HEATING, VENTILATING, & AIR CONDITIONING (Refer to these design documents under separate cover.) ELECTRICAL (Refer to these design documents under separate cover.) NORTH SCALE:3/32" = 1'-0"1 CODE PLAN CLIENT ARCHITECT CIVIL ENGINEER STRUCTURAL ENGINEER GENERAL CONTRACTOR I hereby certify that the portion of this technical submission described below was prepared by me or under my direct supervision and responsible charge. I am a duly licensed architect under the laws of the State of Iowa. Registration Expires Pages or Sheets covered by this seal: Signature O L NAEROF NSCEEWOI AIDLP TCECTIHA RSS I IA Reg. # Date ARCHITECT As listed June 30, 2021 Michael W. Simonson 2704 Michael W. Simonson 2704 JURISDICTION Simonson & Associates Architects L.L.C. 1717 Ingersoll Avenue, Suite 117 Des Moines, IA 50309 (515) 440-5626 (515) 440-0964 Fax contact: Stephanie Poole e-mail: spoole@simonsonassoc.com Civil Design Advantage 3405 SE Crossroads Dr., Suite G Grimes, IA 50111 (515) 369-4400 (515) 369-4410 Fax contact: Ryan Hardisty e-mail: RyanH@cda-eng.com Raker Rhodes Engineering, LLC 4717 Grand Ave. Des Moines, IA 50312 (515) 277-0275 (515) 277-0276 Fax contact: John Rhodes e-mail: jrhodes@rakerrhodes.com contact: Chris Harre e-mail: charre@rakerrhodes.com Hubbell Construction Services 6900 Westown Parkway West Des Moines, IA 50266 (515) 243-3228 (515) 280-2000 Fax Fax contact: Colleen Ladd e-mail: colleen.ladd@hubbellrealty.com phone: (515) 221-6201 contact: (407) 489-3626 (mobile) Hubbell Realty Company - Managing Member 6900 Westown Parkway West Des Moines, Ia 50266 (515) 243-3228 (515) 280-2000 Fax contact: Kris Saddoris e-mail: Kris.Saddoris@hubbellrealty.com phone: (515) 280-2078 contact: Matt Weller e-mail: matt.weller@hubbellrealty.com phone: (515) 280-2041 City of Pleasant Hill City Hall 5160 Maple Drive, Suite A Pleasant Hill, IA 50327 (515) 262-9368 (515) 262-9570 Fax contact: Mike Sporleder, Senior Building Inspector e-mail: msporleder@pleasanthilliowa.org BUILDING SUMMARY DRIVING CODE REVIEW USE & OCCUPANCY TYPE OF CONSTRUCTION AREA & HEIGHT FIRE SPRINKLER & TYPE ENERGY CODE METHOD A-3 VB 2822 SF NO PERSCRIPTIVE OCCUPANT LOAD (TABLE 1004.1.2) AREA SQFT OCCUPANT LOAD OCCUPANTS BUSINESS 833 SF 150 SF 7 COMMUNITY 918 SF 15 SF 62 FITNESS 651 SF 50 SF 14 KITCHENETTE 175 SF 200 SF 1 STORAGE 213 SF 300 SF 2 UTILITY 91 SF 300 SF 1 2882 SF 87 The following is not intended to be an all inclusiv e list, but rather a general summary. Code Referenced: 2018 INTERNATIONAL BUILDING CODE (IBC) CHAPTER 3 -USE & OCCUPANCY CALSSIFICATION A-3 ASSEMBLY -intended for worship, recreation or amusement (Section 303) CHAPTER 5 -GENERAL BUILDING HEIGHTS AND AREAS Allowable Height (Table 503 & Section 504): 1 Stories 40' Height Actual Height: 1 STORY & <40' Allowable Area (Table 503 & Section 506): 6,000 SF (Table 503) Frontage Increase NOT NEEDED Actual Square Footage: 2,723 SQUARE FEET Mixed Use & Occupancy (Section 508): NO SEPARATION REQUIRED FOR ACCESSORY OCCUPANCIES (Section 508.2) Aggregate accessory occupancies shall not occupy more than 10 percent of the building area of the story in which they are located & shall not exceed the tabular values in Table 503, without building area increases. (Section 508.2.1) NO SEPARATION REQUIRED FOR INCIDENTAL ACCESSORY OCCUPANCIES (Sec.&Tab. 508.2.5) CHAPTER 6 -TYPES OF CONSTRUCTION: Fire-Resistance Rating Requirements fir Building Elements (Table 601):TYPE VB (Wood; Non-Rated) No Fire-Resistance Rating Requirements for Building Elements such as Structural Frame, Int./Ext. Walls, Floor or Roof. However, building materials must be non-combustible. Fire-Resistant Rating Requirements for Exterior Walls Based On Fire Separation Distance (Table 602): >30' No Fire-Resistance Rating Requirements CHAPTER 7 -FIRE AND SMOKE PROTECTION FEATURES Maximum Area of Exterior Wall Openings (Table 705.8): (Not less than the fire-resistance rating required by other requirements) NO RESTRICTIONS ON AREA OF EXTERIOR WALL OPENINGS >30' AWAY. NON-SPRINKLERED. Draft-Stopping in Attics (Section 718.4): (A material, devise or construction installed to restrict the movement of air within open spaces of concealed area of building components.) NO AREA >3,000SF 2018 IBC CODE ANALYSIS Code Referenced: 2018 INTERNATIONAL PLUMBING CODE (IPC) & LOCAL ORDINANCE 158.02 Local Ordinance 158.02, #9 states: Section 422 Minimum Number of Required fixtures shall be deleted along with Table 422.1 and replaced with sections 403.1 through 403.5 and Table 403.1 of the 2018 International Plumbing Code to determine minimum required plumbing fixtures. Classification & Use Group: A-3 Number of Occupants: 339 TOTAL - 170 MALE; 170 FEMALE Minimum Number of Required Plumbing Fixtures (Table 403.1): WATER CLOSETS REQUIRED:MALE -2 (1 PER 125); FEMALE -3 (1 PER 65) WATER CLOSETS PROVIDED:MALE -3;FEMALE -3 LAVATORIES REQUIRED:MALE -1 (1 PER 200);FEMALE -1 (1 PER 200) LAVATORIES PROVIDED:MALE -1;FEMALE -1 DRINKING FOUNTAINS REQUIRED:1 -Shall install 2-Hi & Low or 1 that complies for people who use a wheelchair and standing person (Section 1109.5.1) DRINKING FOUNTAINS PROVIDED:2 -Hi & Low or 1 that complies with both requirements SERVICE SINKS REQUIRED:1 SERVICE SINKS PROVIDED:1 PLUMBING FIXTURE REQUIREMENTS Code Referenced: 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) Climate Zone, Moisture Regimes, and Warm-Humid Designations (Figure & Table 301.1): POLK COUNTY, IOWA -5A Commercial Energy Efficiency (Chapter 4): These commercial buildings shall meet either the requirements of ASHRAE/IESNA Standard 90.1, Energy Standard for Buildings Except for Low- Rise Residential Buildings, or the requirements contained in this Chapter. (Section 501.1) Building Envelope Requirements -Opaque Thermal Envelope Requirements (Table C402.1.3): All other than Group R Roofs Insulation entirely above deck R-25ci (ci=Continuous Insulation) Attic and other R38 Walls, Above Grade Other R-13 + R-3.8ci or R-20 Below grade wall R-7.5ci (ci=Continuous Insulation) Slab-on-Grade Floors Heated slabs R-15 for 36" below Swinging doors U -0.37 Roll-up or sliding doors R-4.75 Building Envelope Requirements: Fenestration (Table 402.4): All other than Group R Vertical fenestration U-Factor Fixed fenestration 0.38 Operable fenestration 0.45 Entrance door 0.77 SHGC SHGC 0.40 2012 INT'L ENERGY CONSERVATION CODE ANALYSIS 1. THESE DOCUMENTS & THE DESIGN THEY REPRESENT ARE THE PROPERTY OF SIMONSON & ASSOCIATES ARCHITECTS LLC. NO CHANGES TO THESE DOCUMENTS EITHER IN WHOLE OR IN PART MAY BE MADE IN ANYWAY WITHOUT THEIR PRIOR KNOWLEDGE & WRITTEN CONSENT. 2. REFER TO ADDITIONAL NOTES AND LEGENDS ON ALL OTHER DOCUMENTS. 3. REFER TO CIVIL, GEOTECHNICAL, ENVIRONMENTAL, STRUCTURAL, FIRE SUPPRESSION, PLUMBING, MECHANICAL, ELECTRICAL, COMMUNICATIONS, ELECTRONIC SAFETY & SECURITY DOCUMENTS FOR ADDITIONAL INFORMATION OR REQUIREMENTS. REFERENCE TO OTHER DISCIPLINES IS CONCEPTUAL FOR PURPOSES OF COORDINATION WITH ARCHITECTURAL DESIGN ONLY. 4. BEFORE COMMENCEMENT OF ANY WORK, CONTRACTOR SHALL GIVE ALL NOTICES AND OBTAIN ALL PERMITS. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES,LAWS, ORDINANCES, RULES, REGULATIONS, REQUIREMENTS OF GOVERNING AGENCIES AND AUTHORITIES, HAZARDOUS MATERIAL APPLICATION AND DISPOSAL REQUIREMENTS, ETC. 5. THE ADA OR ADAAG IS A CIVIL RIGHTS ACT AND IS SUBJECT TO LEGAL INTERPRETATION THROUGH THE JUDICIAL PROCESS. REASONABLE CARE WAS EXERCISED IN INTERPRETING THE GUIDELINES AND ALL GUIDELINES MAY NOT BE INDICATED ON THESE PLANS: HOWEVER, FAILURE TO IDENTIFY A GUIDELINE DOES NOT GIVE THIS CONTRACTOR THE RIGHT TO VIOLATE THEM. THE CONTRACTOR MUST COMPLY WITH ALL GUIDELINES AS REQUIRED BY THE ADAAG. 6. THESE DRAWINGS REPRESENT THE COMPLETED PROJECT, AT TIME OF SUBSTANTIAL COMPLETION. THE INTENT OF THE DRAWINGS IS TO INCLUDE ALL ITEMS NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. UNLESS OTHERWISE NOTED, THEY DO NOT REPRESENT THE MEANS AND METHODS OF CONSTRUCTION. SEQUENCING AND MEANS AND METHODS OF CONSTRUCTION SHALL BE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 7. THESE DRAWINGS DO NOT CONTAIN INFORMATION WITH REGARD TO CONSTRUCTION SAFETY PROCEDURES. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL CONSTRUCTION SAFETY AND SHALL PERFORM ALL WORK IN ACCORDANCE WITH GOVERNING AUTHORITIES CONSTRUCTION SAFETY GUIDELINES. 8. PROVIDE COMPLETE IN PLACE ALL LABOR, TRANSPORTATION, MATERIAL, TAXES, FEES, PERMITS, LICENSES, INSURANCE, UTILITIES, INSPECTIONS, EQUIPMENT,MACHINERY, SUPERVISION, AND OTHER ITEMS NECESSARY TO COMPLETE THE WORK IN STRICT COMPLIANCE WITH THE PLANS, DOCUMENTS AND SPECIFICATIONS PREPARED BY THE ARCHITECT AND APPROVED BY THE OWNER. 9. VERIFY EXISTING CONDITIONS PRIOR TO FABRICATION AND PRIOR TO PROCEEDING WITH THE WORK, AND NOTIFY THE ARCHITECT IMMEDIATELY OF SIGNIFICANT DISCREPANCIES WHICH MAY IMPACT AESTHETICS, DURABILITY, COST AND/OR SCHEDULES. 10. DO NOT SCALE DRAWINGS IN ORDER TO DETERMINE INTENDED LAYOUT OR DIMENSIONS. IF DIMENSIONS ARE IN QUESTION THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION BEFORE CONTINUING WITH WORK. DRAWINGS ARE INTENDED ONLY AS A GRAPHICALLY CORRECT REPRESENTATION OF WORK TO BE ACCOMPLISHED. 11. THE CONTRACTOR SHALL PROTECT ALL EXISTING ENTITIES. REMOVE, REPLACE OR REPAIR MATERIALS, FACILITIES AND SERVICES DAMAGED DURING THE COURSE OF CONSTRUCTION TO THE SATISFACTION OF THE OWNER AND GOVERNING AUTHORITY. 12. ALL WORK SHALL BE OF GOOD QUALITY AND ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND FREE FROM DEFECTS FOR A PERIOD OF 1 YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION OF WORK. ANY EXTENDED WARRANTIES OBTAINED FROM SUPPLIERS OR SUBCONTRACTORS SHALL BE FORWARDED TO THE OWNER. 13. ALL REQUIREMENTS NOT FOLLOWED, INCLUDING SUBSTITUTIONS NOT PROPERLY APPROVED AND AUTHORIZED, IN WRITING, MAY BE CONSIDERED DEFECTIVE. 14. FAILURE TO IDENTIFY A STANDARD, RECOMMENDATION &/OR REQUIREMENT DOES NOT GIVE ANYONE THE RIGHT TO VIOLATE ANY CODE & GOVERNING AUTHORITY REQUIREMENTS, MINIMUM QUALITY OR QUANTITY REQUIRED, ASTM & OTHER INDUSTRY STANDARDS, MANUFACTURER RECOMMENDATIONS & REQUIREMENTS, ETC. 15. COMPLY WITH ALL WEATHER-RELATED CONSTRUCTION REQUIREMENTS. DO NOT BUILD WITH OR ON FROZEN, SATURATED, CONTAMINATED OR INAPPROPRIATE SUBSTRATES OR CONDITIONS. BUILD OVER DRY COMPACTED APPROVED GRADE WITH APPROVED APPROPRIATE MATERIALS. 16. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM AND OFF ALL BUILDINGS WITHOUT PONDING OR WATER ADJACENT TO OR ON BUILDINGS OR PAVEMENTS. 17. BY SUBMITTING SHOP DRAWINGS, PRODUCT DATA AND SAMPLES, THE GENERAL CONTRACTOR AND SUB-CONTRACTOR HAS VERIFIED AND APPROVED THE INFORMATION CONTAINED WITHIN. THE GENERAL CONTRACTOR'S REVIEW AND APPROVAL SHALL BE SHOWN ON EACH SUBMITTAL PRIOR TO THE SUBMISSION TO THE ARCHITECT. 18. THE GENERAL CONTRACTOR SHALL FORWARD TO SUBCONTRACTORS & SUPPLIERS, FULL SETS OF BIDDING &/OR CONSTRUCTION DOCUMENTS, INCLUDING, BUT NOT LIMITED TO, DRAWINGS, SPECIFICATIONS, ADDENDA, CLARIFICATIONS, BID FORMS, & ALL OTHER DOCUMENTATION ISSUED BY ARCHITECT & ARCHITECT'S CONSULTANTS TOWARD CONVEYING A COMPLETE & TIMELY PROJECT. GENERAL NOTES OCCUPANT LOAD - POOL (TABLE 1004.1.2) AREA SQFT OCCUPANT LOAD OCCUPANTS POOL 1497 SF 50 SF 30 POOL DECK 4616 SF 15 SF 308 6113 SF 338 09-30-2020 Rev. #Issue / RevisionDate130% Set12-03-2021CHAPTER 8 -INTERIOR FINISHES Interior wall & ceiling finish materials, including acoustical ceiling systems, shall be classified for allowable fire performance & smoke development as allowed by this code. (Section 803 & 808) Interior floor finish & floor covering materials shall be classified in accordance with NFPA 253 & this code. (Section 804) Decorative materials shall not exceed 10% of the wall or ceiling area to which they are attached. Trim & wall base shall be classified for allowable accordance with the code. (Section 806) CHAPTER 9 -FIRE PROTECTION SYSTEMS Automatic Sprinkler Systems (Section 903): AUTOMATIC SPRINKLER NOT REQUIRED A-3 fire area exceeds12,000sf or occupant load of 300 or more (Section 903.2.1.2) Portable Fire Extinguishers (Section 906 refers to IFC 906): EXTINGUISHERS REQUIRED Class A Fire Hazards (Business) -Max. travel distance <75' (Table 906.3(1)). CHAPTER 10 -MEANS OF EGRESS Minimum Required Egress Width (Section 1005.1): REQUIRED: Egress Components -88 Occ. x .2" = 17.6"(32" Clear Min.); PROVIDED: 102" Door Swing (Section 1008.1.2): Doors shall swing in the direction of egress travel where serving an occupant load of 50 or more persons or a Group H occupancy. Panic & Fire Exit Hardware (Section 1008.1.10): Each egress door from Group A or E occupancy having an occupant load of 50 or more or any H shall not be provided with a latch or lock unless it is panic hardware or fire exit hardware. Common Path of Egress Travel (Section 1014.3): <75' (H<25') NS; or B,F,S<100' if Sprinklered (A<30' or <75' if <50occ. -Sec. 1025.8) or (H<25') Exit Access Travel Distance (Table 1016.1 ): A,B,E,F-1,M,R,S-1 <200', F-2,S-2,U <300' NS; or A,E,F-1,M,R,S-1 <250', B <300', F-2,S-2,U <400' if Sprinklered; (I&H <? see book) Minimum Number of Exits (Section 1015 &1021, Table 1015.1,1021.1&.2): 2 REQUIRED; 2 PROVIDED Number of Accessible Means of Egress (Section 1007.1): 2 REQUIRED (1 if only 1 exit required) Corridor Fire-Resistance Rating (Table 1018.1): NO RATING REQUIRED. (An enclosed exit access component that defines and provides a path of egress travel to an exit.) ACCESSIBILITY (Chapter 11): Buildings and facilities shall be designed and constructed to be accessible in accordance with this code and ICC/ANCI A117.1. CHAPTER 15 -ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Roof Fire Classification (Table 1505.1): CLASS C Building Types IIB,IIIB,VB requires CLASS C roof assembly. Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.NOT FOR CONSTRUCTIONSAA J:\2021\21113 Waukee Crossing Multi-Family - Hubbell\CAD-Arch\21113 Converge NW, Waukee, IA_Clubhouse.rvt12/3/2021 11:20:37 AMCONVERGE NWCLUBHOUSEWAUKEE, IOWA21113 G-001 SPECIFICATION NOTES SP DIVISION 01 – GENERAL REQUIREMENTS GENERAL: 1. Refer to additional notes and requirements on all other documents and other disciplines documents. 2. In the event that a discrepancy is found between any codes, governing authority, drawings, documents, or any other requirements, the most restrictive or stringent requirement shall be used. 3. Cooperate fully with separate contractors so work on those contracts may be carried out smoothly, without interfering with or delaying work under separate Contracts. 4. Owner reserves the right to place and install equipment in all areas of building and site, before Substantial Completion, provided it does not interfere with completion of the Work. CONSTRUCTION SCHEDULE - Before commencing Work, submit a schedule showing the sequence, commencement and completion dates for all phases of the Work. Coordinate the Work of this Contract with work performed under separate contracts. TEMPORARY CONSTRUCTION - Provide all required temporary construction, temporary facilities and temporary utilities required to complete the project including but not limited to, erosion control structures, material storage areas, enclosures for tools and other equipment, a field office, temporary utility services for construction usage, temporary heat and cover, and temporary toilet facilities. CLEAN-UP - The Contractor shall be responsible for construction trash removal services and shall at all times keep the building and site free from accumulation of debris. Upon completion, the building, including glazing, and site shall be cleaned and turned over to the Owner. WARRANTY - All work shall be of good quality and all materials and equipment shall be new and free from defects for a period of one year from the date of substantial completion of work. Any extended warranties obtained from suppliers of subcontractors shall be forwarded to the owner. INSURANCE - The Contractor shall maintain Workers' Compensation Insurance and Comprehensive Public Liability and Builders Risk Insurance. QUALITY ASSURANCE - The Contractor shall implement a Quality Assurance program which includes independent agency testing and observation of soils, cast-in-place concrete and structural steel, as well as inspection of work in progress. The owner will have the right to perform inspections and/or independent tests at any time. All lines and levels shall be established by a Registered Land Surveyor. RECORD DOCUMENTS - Upon completion of the project, the Contractor shall prepare a complete set of record documents including a list of Suppliers and Subcontractors used on the project, manufacturer's warranties, operation and maintenance manuals for major pieces of equipment and instruction manuals when appropriate for building systems. SUBMITTALS 1. Allow enough time for submittal review, including time for resubmittals, No extension of the Contract Time will be authorized because of failure to transmit submittals enough in advance of the Work to permit processing, including resubmittals. 2. By submitting shop drawings, product data and samples, the contractor has verified and approved the information contained within. The contractor's review and approval shall be shown on each submittal prior to the submission to the architect. 3. Provide samples for each type and color for review of kind, color, pattern, and texture for a check of these characteristics with other elements. 4. Immediately on discovery of the need for interpretation of the Contract Documents, and if not possible to request interpretation at Project meeting, prepare and submit an RFI. 5. Include as part of each alternate, miscellaneous devices, accessory objects, and similar items incidental to or required for a complete installation whether or not indicated as part of alternate. Modify or adjust affected adjacent work as necessary to completely integrate work of the alternate into Project. QUALIFICATIONS 1. Installer Qualifications: A firm or individual experienced in installing, erecting, or assembling work similar in material, design, and extent to that indicated for this Project, whose work has resulted in construction with a record of successful in-service performance. 2. Manufacturer Qualifications: A firm experienced in manufacturing products or systems similar to those indicated for this Project and with a record of successful in-service performance, as well as sufficient production capacity to produce required units. 3. Fabricator Qualifications: A firm experienced in producing products similar to those indicated for this Project and with a record of successful in-service performance, as well as sufficient production capacity to produce required units. 4. Professional Engineer Qualifications: A professional engineer who is legally qualified to practice in jurisdiction where Project is located and who is experienced in providing engineering services of the kind indicated. Engineering services are defined as those performed for installations of the system, assembly, or product that are similar to those indicated for this Project in material, design, and extent. 5. Specialists: Certain items require that specific construction activities shall be performed by entities who are recognized experts in those operations. Specialists shall satisfy qualification requirements and shall be engaged for the activities indicated. 6. Testing Agency Qualifications: An independent agency with the experience and capability to conduct testing and inspecting indicated and where required by authorities having jurisdiction, that is acceptable to authorities. 7. Factory-Authorized Service Representative Qualifications: An authorized representative of manufacturer who is trained and approved by manufacturer to inspect installation of manufacturer's products that are similar in material, design, and extent to those indicated for this Project. 8. Manufacturer's Warranty: Preprinted written warranty published by individual manufacturer for a particular product and specifically endorsed by manufacturer to Owner. The Specification Notes are organized into Divisions using the CSI/CSC's "MasterFormat" numbering system. The following is not intended to be an all inclusive list, but rather a general summary. Failure to identify a requirement does not give any contractor, general contractor or its sub-contractors the right to violate any codes, governing authority, minimum quality or quantity, industry standards, manufacturer recommendations, etc. DIVISION 02 - EXISTING CONDITIONS GENERAL: 1. Verify existing conditions before fabrication or prior to proceeding with the work, and notify the architect immediately of significant discrepancies. 2. Maintain existing building in a weathertight condition throughout construction period. Repair damage caused by construction operations. Protect building and its occupants during construction period. 3. Perform the Work so as not to interfere with day-to-day operations. Maintain existing exits, unless otherwise indicated. 4. Provide new units to match existing units in body composition, physical properties, color, gloss, surface texture, thickness, profile, dimensions, and composition of surface. 5. Protect persons, motor vehicles, surrounding surfaces of building not effected, building site, plants, and surrounding buildings from harm resulting from any work. When no longer needed, promptly remove masking to prevent adhesive staining. 6. Support and protect remaining construction that surrounds removal area. Maintain flashing, reinforcement, lintels, and adjoining construction in an undamaged condition. 7. In general the overall selection and intent of exterior building materials and finishes are to be similar to those exterior building materials and finishes in existing building unless otherwise specified. DIVISION 03 – CONCRETE Refer to Structural Documents) GENERAL: 1. All concrete shall be reinforced unless otherwise noted. 2. All concrete shall be saw cut. If saw cuts are not specified, contact architect and engineer. If possible provide saw cut under demising walls. 3. Concrete to only be placed over dry sub-grade to prevent heaving in winter. 4. Forms where concrete is to be exposed shall be smooth and free of defects. 5. Exterior paving to be 1/4" lower than interior finish floor, sloping away from building. Where no paving, top of finished grade a minimum of 4" below finish floor. 033500 CONCRETE FINISHING 1. Concrete floor slab shall be installed to a true plane with no deviations greater than 1/4" in any 10'-0" direction and free from blemishes and trowel marks. 2. Trowel Finish: Apply a trowel finish to monolithic slab surfaces exposed to view and slab surfaces to be covered with resilient flooring, carpet, ceramic or quarry tile, paint, or another thin film-finish coating system. Grind smooth any surface defects that would telegraph through applied floor covering system. 3. Nonslip Finish: Apply a nonslip finish, perpendicular to main traffic route, to all exterior concrete platforms, steps, and ramps. 4. Slope requirements for exterior concrete sidewalks of 5% maximum running slope, 2% maximum cross slope, or 8.3% maximum slope for ramps. DIVISION 04 – MASONRY (Refer also to Structural Documents) GENERAL: 1. Large masonry joint or cut masonry unit to maintain masonry coursing joint at finish floor line. 2. STAINLESS STEEL CLIPS ARE REQUIRED FOR ANY MASONRY LARGER THAN 8x16 FACE SIZE. 040100 MAINTENANCE OF MASONRY - If acid wash is used be sure to take appropriate protection measures to eliminate any damage from getting it on other unlike materials. 040513 MASONRY MORTARING - Use mortar made with integral water repellent admixture that does not reduce flexural bond strength where masonry with integral water repellent admixture is required. 040516 MASONRY GROUTING - 1. Use grout made with integral water repellent admixture that does not reduce flexural bond strength where masonry with integral water repellent admixture is required. 2. All voided spaces below grade shall be grouted full. 040519 MASONRY ANCHORAGE AND REINFORCING - Space masonry anchors not more than 16" o.c. vertically and 24" o.c. horizontally with not less than 1 anchor for each 2.67 sq. ft. of wall area. Install additional anchors within 12" of openings and at intervals, not exceeding 36 inches, around perimeter. 040523 MASONRY ACCESSORIES - Joints, Flashing & Drainage 1. Install vertical expansion joint minimal at column/grid lines and at the head of door jambs/openings or as otherwise noted or where required per standard material practice to reduce stress cracking. No control joint/expansion joint at main structural bearing, keep away 2'-6" min. 2. No drip edge required if membrane flashing is used, but it should extend out and be trimmed back to face of adjacent masonry. Drip edge required if metal flashing is used. 3. Through wall flashing at base of wall a minimum of 4" above finish grade back and up behind vapor barrier, weeps at 24" o.c. above flashing, horizontal & vertical joints overlapped & sealed. 4. Through wall flashing above lintels back and up behind vapor barrier, weeps at 24" o.c. above flashing. End dams at openings, horizontal and vertical joints overlapped and sealed. 5. All masonry to have 1" minimum air space away from adjacent material. All cavity wall air spaces are to be maintained free of mortar. Strike flush all joints on cavity side of CMU and brick masonry. Provide mortar net at base of wall, above all lintels and above all intermediate thru-wall flashing. 042100 CLAY UNIT MASONRY (Brick) 1. For ends of sills and caps and for similar applications that would otherwise expose unfinished brick surfaces, provide units without cores or frogs and with exposed surfaces finished. 2. Provide brick that has been tested is rated "not effloresced." 047210 CAST STONE MASONRY - Provide units made with integral water repellent admixture that does not reduce flexural bond strength. DIVISION 05 – METALS (Refer also to Structural Documents) GENERAL: 1. All steel exposed on the exterior or to moisture to be galvanized. 2. All metal coping to be pre-finished. 3. All exposed steel lintels to be painted to match surrounding materials. 4. All architectural steel and metal fabrications to be continuous welds, grinded smooth and sanded for a neat and smooth final finish. 5. All holes 'burned through' steel roof deck when welding shall be repaired and touched up with primer and final finish. DIVISION 06 – WOOD, PLASTICS, AND COMPOSITES (Refer also to Structural documents) GENERAL: 1. All wood framing members, including wood sheathing, that rest on the exterior foundation walls & are less than 8” from exposed earth & all wood in direct contact with masonry, concrete, earth or material that retains moisture shall be of naturally durable or preservative-treated wood. 2. The ends of wood girders entering exterior masonry or concrete walls shall be provided with a 1/2” air space on top, sides and end, unless naturally durable or preservative-treated wood. 3. All wood that is part of a roof/parapet or flashing assembly and are fully wrapped by membrane or break metal and protected from moisture need not be treated. 4. Wood blocking is required for, but not limited to millwork, cabinets, handrails, rest room fixtures & accessories, grab bars, future grab bars as required in R / Multi-family occupancies, door & window frames, overhead door bucks, hardware, owner/tenant fixtures & equipment, etc.. 5. Exterior sheathing should be plywood at all potential signage locations. Fire retardant / rated where required. DIVISION 07 – THERMAL AND MOISTURE PROTECTION GENERAL: 1. Design and installation of roof drainage systems shall comply with the IPC. 2. Insulate and seal to ensure adequate air infiltration barrier around all exterior penetrations to prevent water and sprinkler pipe freezing. 3. Provide 2" thick continuous perimeter rigid insulation min. 24" horizontally from interior face of grade beam into building and vertically to bottom of the grade beam along the interior face. 4. Roof assembly to meet UL Class "A" fire rating. 072100 THERMAL INSULATION - R21 wall insulation unless otherwise noted. 072200 ROOF AND DECK INSULATION - R38 (min. code R19) roof insulation unless otherwise noted. 075000 MEMBRANE ROOFING 1. Roofing membranes should be installed to comply with manufacturers recommendations to obtain full roofing warranties. 2. Provide manufacturers 15-year warranty, which begins after the date of substantial completion, and covers the roofing membrane, associated flashing, roof insulation, roof accessories and labor. 079000 JOINT PROTECTION 1. Provide joint sealant at all wall and floor control and expansion joints and exterior doors, windows and other openings. 2. Provide backer rods where required for proper sealant application. Backer rods to be polyethylene closed-cell with a surface skin. 3. Utilize acoustical sealant at all floor/wall/deck junctures prior to installation of base where sound batt is also required. 4. Sealants to be compatible to materials for maximum bonding and longevity. 5. Soft caulk joint between vertical joints of dis-similar materials. Soft caulk joint & metal pan underneath horizontal joints of dis-similar materials. 6. Sealants should be color matched to adjacent materials. DIVISION 08 – OPENINGS GENERAL: 1. All exterior window framing to be thermally broken. 2. Sill pan by window manufacturer set in mastic over break metal sill flashing, with drip edge, set in mastic at bottom of all window framing. End dams at openings. Horizontal and vertical joints overlapped and sealed. 3. Sealant and backer rod at window perimeter. Verify system weeps are cleared, free of sealant and debris. 4. Additional framing, structural supports and/or bracing shall be identified by the glazing sub-contractor prior to bidding, fabrication and installation. 5. All glass in interior doors, frames, sidelights, windows and storefront to be 1/4", tempered, laminated and/or rated glass where required. 6. All glass in exterior doors, frames, sidelights, windows and storefront to be insulated, tempered, laminated and/or rated glass where required. 7. All interior glass between tempered and non-tempered spaces shall be clear insulated. 081000 DOORS & FRAMES - (Refer to Door & Frame Schedule & Elevations) 083000 ACCESS DOORS & PANELS - 2006 IBC-1209.2 Access to ATTIC SPACES. An opening not less than 20" by 30" shall be provided to any attic area having a clear height of over 30". 084000 ENTRANCES, STOREFRONTS, & CURTAIN WALLS - (Refer to Door & Frame Schedule & Elevations) 08 50 00 WINDOWS - (Refer to Window Schedule & Elevations) Operating hardware for operable windows, etc. shall be placed within one or more of the ANSI accessible reach ranges, shall be operable with one hand & shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be 5.0 pounds maximum. 08 83 00 MIRRORS Mirrors above accessible lavatories shall have the bottom edge of the reflecting surface 40” maximum above the floor. DIVISION 09 – FINISHES GENERAL: 092116 GYPSUM BOARD ASSEMBLIES 1. All gypsum board to be smooth finish, properly taped and sanded, ready for finish. 2. Gypsum board expansion joints shall be used where required per standard gyp. board practice to prevent cracking of drywall. 099100 PAINTING - All paint finish shall be primed followed by 2 coats of high quality finish paint. Gypsum board shall be latex paint, interior metals shall be epoxy paint, exterior metals shall be a three-coat Tnemec system. If smooth surface, material should be sanded between all coats. All steel doors & metal frames shall be spray applied paint. 099300 STAINING AND TRANSPARENT FINISHING - All wood finish shall be left natural or stained as noted, followed by 2 coats of high quality transparent coating. Material should be sanded between all coats. 099713 STEEL COATINGS - Interior metals shall be epoxy paint, exterior metals shall be a three-coat tnemec system. DIVISION 10 – SPECIALTIES GENERAL: Window coverings, toilet accessories, lockers, and flagpole shall be provided. 10 14 00 SIGNAGE: Provide all that apply. All signage shall comply with the ICC A117.1 requirements, where required, such as visual characters, raised characters, international symbols of accessibility, & braille. 1. BUILDING ADDRESS IDENTIFICATION: Approved address numbers or letters, where each character shall be not less than 4” in height and not less than 0.5” in width stroke, shall be installed on a contrasting background and be plainly visible from the street or road fronting the property (& monument sign). When required by the governing authority, address numbers shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or approved sign or means shall be used to identify the structure. Address numbers shall be maintained. 2. OCCUPANT LOAD: Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. 3. DIRECTIONAL SIGNAGE: Direction signage indicating the location of the other means of egress and which are accessible means of egress shall be provided: 1. At exits serving a required accessible space but not provided an approved accessible means of egress. 4. DOORS OPERATIONS: In buildings in occupancy Group A having an occupant load of 300 or less, Groups B,F,M & S, and in places of worship, the main exterior door or doors are permitted to be equipped with key-operated locking devices from the egress side provided: 2.1 The locking devise is readily distinguishable as locked; 2.2 A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WITH BUILDING IS OCCUPIED. The sign shall be in letters 1” high on a contrasting background; and 2.3 The use of the key-operated locking device is revocable by the building official for due cause DIVISION 10 – SPECIALTIES (cont.) 11. ACCESSIBLE SIGNAGE MOUNTING REQUIREMENTS: 1. Visual characters shall be located 40” minimum above the floor to less than or equal to 70” at the viewing position distance (less than 6’), measured to the baseline of the visual character. 2. Raised characters shall be located 48” minimum above the floor, measured to the baseline of the raised character & 60” maximum above the floor, measured to the baseline of the highest raised character. 3. Where a sign containing raised characters & braille is provided at a door, the sign shall be alongside the door at the latch side. Where a sign containing raised characters & braille is provided at double doors with one active leaf, the sign shall be located on the inactive leaf. Where a raised characters & braille is provided at double doors with two active leafs, the sign shall be to the right of the right-hand door. Where there is no wall space on the latch side of a single door or the right side of double doors, signs shall be on the nearest adjacent wall. Signs containing raised characters & braille shall be located so that a clear floor area 18” minimum by 18” minimum, centered on the raised characters is provided beyond the arc of any door swing between the closed position & 45 degree position. 4. Braille shall be located 48” minimum & 60” maximum above the floor, measured to the baseline of the braille cells. 12. ACCESSIBLE PARKING SPACE IDENTIFICATION SIGNS: 1. Parking space identification signs shall include the International Symbol of Accessibility. Signs identifying van parking spaces shall contain the designation “van accessible”. Signs shall be 60” minimum above the finish floor or ground surface measured to the bottom of the sign. 10 20 00 TOILET COMPARTMENTS - (Refer to Rest Room Details) 10 28 00 TOILET, BATH, AND LAUNDRY ACCESSORIES - (Refer to Rest Room Accessory Schedule) 10 41 16 EMERGENCY KEY CABINETS - Provide a recessed Knox box ordered from or approved by and installed in a location approved by governing authorities. 10 44 16 FIRE EXTINGUISHERS - Provide and install fire extinguishers, 10 pound ABC or as approved by governing authorities, by each exit and a maximum travel distance of no more than 75'-0" per placement, or as required by governing authorities. Fire extinguisher shall be in a semi- recessed cabinet when located in common areas. 10 55 00 POSTAL SPECIALTIES – Provide ADA mailboxes & parcel boxes manufactured to USPS specifications for all multi-family projects. 10 73 00 AWNINGS OR CANOPIES OR SHUDDERS – Alternative premanufactured versions may be acceptable alternative if approved by owner & architect. SPECIFICATION NOTES cont. SPECIFICATION NOTES cont. SPECIFICATION NOTES cont. SPECIFICATION NOTES cont. SPECIFICATION NOTES cont. DIVISION 11 – EQUIPMENT GENERAL: 111300 LOADING DOCK EQUIPMENT - (Refer to Dock Accessory Schedule) 11 31 13 KITCHEN APPLIANCES – Lighting controls, electrical panelboards, electrical switches & receptacle outlets, environmental controls, etc. shall be placed within one or more of the ANSI accessible reach ranges, shall be operable with one hand & shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be 5.0 pounds maximum. Exceptions include: reset button and shut-offs serving appliances, piping & plumbing fixtures; appliance doors and door latching devises shall not be required to comply with the one hand, tight grasping, pinching, twisting or force requirements; bottom hinged appliance doors, when in the open position, shall not be required to comply with reach ranges. The location of cooktop controls shall not require reaching across burners. Ovens shall have controls on front panel, on either side of the door & shall not require reaching across burners. Side-hinged door ovens shall have a countertop positioned adjacent to the latch side of the oven door, bottom- hinged door ovens shall have a countertop positioned adjacent to one side of the door. Combination refrigerators & freezers shall have at least 50% of the freezer compartment shelves, including the bottom of the freezer 54” maximum above the floor when the shelves are installed at the maximum heights possible in the compartment. DIVISION 21 – FIRE SUPPRESSION (Refer to Fire Suppression scope/documents & Utility requirements) GENERAL: 1. All penetrations thru rated walls must be protected by approved fire rated assemblies and fire stopping materials. 211000 WATER-BASED FIRE-SUPPRESSION SYSTEMS 1. Provide a complete appropriate type and adequately sized design build fire sprinkler system as required and approved by governing authorities prior to fabrication and installation. All conditioned / insulated (wet pipe system) and non-conditioned / uninsulated (dry pipe system) spaces will need to be sprinklered unless otherwise noted. 2. Contractor to verify size of main supply line and notify architect and owner immediately before sitework commences if over or under-sized. 3. Riser system shall be installed separate from electrical room or electrical panels and be flow tested and continuously monitored. 4. Fire department valve at exterior as required by governing authorities. 5. System drainage shall dump to outside of building on pavement, not floor drain. 6. Sprinkler system shall be zoned and expandable for all future tenants. 7. For shell building, provide minimal sprinkler heads turned up or as required by governing authorities. DIVISION 22 – PLUMBING (cont.) 5. GREASE TRAP/INTERCEPTOR: (not required) and/or Provide adequately sized system based on future potential information provided by owner/developer as approved by governing authorities. Provide a continuous tap-able discharge line under slab the entire length of building (side to side) approximately one third of overall building depth off the back wall of building, that would allow future service taps from any location within the building. Provide clean-outs and vent lines as required. 221400 FACILITY STORM DRAINAGE 1. Pitched Roofs - Provide adequately sized and spaced roof drains, gutters, downspouts and drain piping system, to eliminate any overflow or backup, from all roof to site stormwater piping system and/or detention area. 2. Provide collection system along low parts of building roof to be collected in gutters, down spouted and dumped on pavement or splash blocks below. 3. Provide lower level underfloor drainage system to reduce hydrostatic uplift and protect against moisture seepage. System to outlet per governing authorities. 4. Provide foundation wall drainage system to reduce lateral pressures and protect against moisture seepage. System to outlet per governing authorities. 5. Provide adequately sized and spaced gutters, down spouts and drain piping system, to eliminate any overflow or backup. 2006 IBC-1503.4 ROOF DRAINAGE. Design and installation of roof drainage systems shall comply with the International Plumbing Code. Refer to Plumbing documents for final design and details. 2006 IBC-1611.3 CONTROLLED DRAINAGE. Roofs equipped with hardware to control the rate of drainage shall be equipped with a secondary drainage system at a higher elevation. 223000 PLUMBING EQUIPMENT 1. Water Softener - Provide. 2. Water Filter - Provide. 3. Water Heater - Provide. 22 40 00 PLUMBING FIXTURES Plumbing fixture controls, faucets, etc. shall be placed within one or more of the ANSI accessible reach ranges, shall be operable with one hand & shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be 5.0 pounds maximum. Exceptions include: where redundant controls are provided for a single element, one control in each space shall not be required to be accessible; reset buttons and shut-offs serving piping & plumbing fixtures. 22 40 16 LAVATORIES & SINKS The Dip of the overflow shall not be considered in determining knee and toe clearance. The front of lavatories & sinks shall be 34” maximum above the floor, measured to the higher of the rim or counter surface. A lavatory in a toilet or bathing facility for a single occupant, accessed only thru a private office & not for common use or public use shall not be required to meet 34” height max. Water supply & drainpipes under lavatories & sinks shall be insulated or otherwise configured to protect against contact. There shall be no sharp or abrasive surfaces under lavatories. 22 40 13 WATER CLOSETS , URINALS, & BIDETS Water Closets: The required clearance around the water closet shall be permitted to overhang the water closet, associated grab bars, paper dispensers, coat hooks, shelves, accessible routes, color floor space required at other fixtures, and the wheelchair turning space. No other fixtures or obstructions shall be located within the required clearance. The top of the water closet seat shall be 15” minimum & 19” maximum above the floor, measured to the top of the seat. Flush controls shall be hand operated or automatic. Hand operated flush controls shall be located on the open side of the water closet. DIVISION 23 – HEATING, VENTILATION, AND AIR CONDITIONING (Refer to Mechanical scope/documents & Utility requirements) GENERAL: 1. Provide a new complete shell building mechanical distribution, return and ventilation system and coordinate mechanical requirements for all building equipment and fixtures. 2. All information shall be clearly documented and provided to owner and architect. 3. If provided, all systems should be sized to include all future tenants. 4. Provide independently controlled areas having excessive heat gain or heat loss or affected by solar radiation at different times of the day. 5. Verify location of all thermostats with owner before permanent placement. 6. Provide exhaust fans in all rest rooms, bathrooms, kitchens, break rooms, shafts and enclosed parking areas. 7. Clean all systems and provide new filters after construction is complete. 8. At a minimum, if other heat is not provided, provide electric baseboard heat in Valve Room or any other rooms that contain plumbing. 9. Environmental controls, etc shall be placed within one or more of the ANSI accessible reach ranges, shall be operable with one hand & shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be 5.0 pounds maximum. Exceptions include: HVAC diffusers; controls mounted on ceiling fans; where redundant controls are provided for a single element, one control in each space shall not be required to be accessible; reset buttons and shut-offs serving piping. Access To MECHANICAL APPLIANCES. Access to mechanical appliances installed in under-floor areas, in attic spaces and on roofs or elevated structures shall be in accordance with the International Mechanical Code. Refer to Mechanical documents for final design and details. 23 09 00 INSTRUMENTATION & CONTROL FOR HVAC Thermostats shall be placed within one or more of the ANSI accessible reach ranges & all controls 48” height maximum from finished floor. DIVISION 25 – INTEGRATED AUTOMATION (Refer to Electrical scope/documents) GENERAL: 1. If requested, provide complete flexible electronic building management systems to control all building functions including but not limited to HVAC, lighting, security, card reader access, fire/sprinkler alarm, etc. DIVISION 26 – ELECTRICAL (Refer to Electrical scope/documents & Utility requirements) GENERAL: 1. Provide a complete flexible shell building electrical distribution system and coordinate power requirements for all shell building equipment/fixtures. 2. All information shall be clearly documented and provided to owner and architect. 3. All systems should be sized to include all future tenants. 4. Lighting controls, electrical panelboards, electrical switches & receptacle outlets, environmental controls, etc. shall be placed within one or more of the ANSI accessible reach ranges, shall be operable with one hand & shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be 5.0 pounds maximum. Exceptions include: Receptacle outlets serving a dedicated use; where two or more receptacle outlets are provided in a kitchen above a length of counter top that is uninterrupted by a sink or appliance, one receptacle outlet shall not be required to comply; floor receptacle outlets, controls mounted on ceiling fans; where redundant controls other than light switches are provided for a single element, one control in each space shall not be required to be accessible; electrical panelboards shall not be required to comply with the one hand, tight grasping, pinching, twisting or force requirements. NOTE: Electric sub-contractor shall calculate & verify the required size of the service/transformer with utility company. 262000 ELECTRICAL DISTRIBUTION - Provide an electrical distribution system complying with requirements of governing authorities. 265200 EMERGENCY LIGHTING - Provide dual beam emergency lights with battery back-up to provide a minimum 1 foot-candle, at floor level, throughout egress system or as required by governing authorities. 265300 EXIT SIGNS - Provide lighted exit signage with battery back-up by each exit and throughout egress system as required by governing authorities. Exit signs at doors shall be on the door or within 4" of the door frame. 265600 EXTERIOR LIGHTING - 1. Provide downlites to illuminate each exterior door. 2. Provide recessed downlites in each entry canopies. 4. All exterior building lighting shall be flexibly controlled by both photocell & timer. 5. All fixtures must be approved by governing authorities before installation. DIVISION 27 – COMMUNICATIONS (Refer to Electrical & Life-Safety scope/documents & Utility requirements) GENERAL: 1. If provided, all systems should be expandable to include all future tenants. 2. Provide communication lines for fire sprinkler, fire alarm and/or security monitoring as required by governing authorities. 3. Provide 3 4" conduits (1 for telecommunications; 2 extra) from services R.O.W. To termination location at building location as noted. 4. Provide telecommunication service to d-mark for lines for fire sprinkler and fire alarm monitoring as required by governing authorities. 5. User controls for intercom systems, etc. shall be placed within one or more of the ANSI accessible reach ranges, shall be operable with one hand & shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be 5.0 pounds maximum. Exceptions include: where redundant controls are provided for a single element, one control in each space shall not be required to be accessible. DIVISION 28 – ELECTRONIC SAFETY AND SECURITY (Refer to Electrical & Life-Safety scope/documents) GENERAL: 1. If provided, all systems should be expandable to include all future tenants. 2. User controls for security or intercom systems, etc. shall be placed within one or more of the ANSI accessible reach ranges, shall be operable with one hand & shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be 5.0 pounds maximum. Exceptions include: where redundant controls are provided for a single element, one control in each space shall not be required to be accessible. 281000 ACCESS CONTROL & SECURITY - If requested, provide complete electronic building access control and security system expandable to include future tenants. 283100 FIRE DETECTION AND ALARM - Provide a complete addressable zoned fire alarm system with point identification and all audio-visual / horn- strobe devices, smoke detectors, and pull stations as required and approved by governing authorities prior to fabrication and installation. 2006 IBC-1006.2 Means of Egress ILLUMINATION. The means of egress illumination level shall not be less than 1 foot-candle at the walking surface level. 2006 IBC-1006.3 ILLUMINATION EMERGENCY POWER. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: Interior & Exterior egress components. DIVISION 31 – EARTHWORK (Refer to Civil & Geotechnical documents) GENERAL: 1. Provide excavation, backfill and fine grading for the building, paved areas, and proper site drainage. 2. Provide silt fence, clearance of trees, grubbing of stumps, curb removal, stripping of topsoil, excavation and backfill for foundations, place sand cushion for slabs on grade, grading for paving and re- spreading of top soil. 3. Provide site landscaping i.e., seeding, sodding, spreading on site topsoil, trees, mulch, edging, and shrubbery. 4. Exterior grading to be 4" lower than adjacent interior finish floor, sloping away from building. DIVISION 32 - EXTERIOR IMPROVEMENTS (Refer to Civil & Geotechnical documents) 32 10 00 PAVING 32 80 00 IRRIGATION: (not required) and/or Provide separate water line and irrigation meter which shall be located in valve room. Provide irrigation supply lines from valve room to exterior providing service to all sides of exterior of building. Provide complete zoned irrigation system to cover all plantings & grass areas of the site. DIVISION 33 – UTILITIES (Refer to Civil documents) GENERAL: 1. All utilities should be sized and expandable to include all future tenants. 2. All utilities shall be stubbed to within 5 feet of the building per Civil/Site engineering documents unless otherwise specified. 3. All utilities shall be adequately sized and spaced to eliminate any overflow and/or backup. 331000 WATER UTILITIES 1. Provide separate domestic water supply service as required from water main to house service meter with irrigation meter in valve room. 2. Provide separate fire sprinkler water supply service as required from water main to sprinkler riser located in valve room. NOTE: Sprinkler sub-contractor shall calculate the required size of the line to the building and shall notify the G.C. & owner immediately if any modification from Civil/Site documents is required. 333000 SANITARY SEWERAGE UTILITIES - Provide sanitary sewer discharge service as required from under building slab to sanitary sewerage main. 334000 STORM DRAINAGE UTILITIES - Provide storm water discharge service as required from building and/or adjacent to building to storm water main or thru detention area. 335100 NATURAL-GAS UTILITIES - Provide natural gas supply service as required from natural gas main to meter/manifold location at building. 337000 ELECTRICAL UTILITIES - Provide electric supply service as required from electric main to transformer location. Provide appropriately sized transformer and concrete pad as required. NOTE: Electric sub- contractor shall calculate & verify the required size of the service/transformer with utility company. 338000 COMMUNICATIONS UTILITIES - Provide conduits from public R.O.W. to the buildings designated location for the required communications. End of Specification Notes 5. EXIT SIGNS (non-illuminated tactile type): Raised character and Braille exit signs. A sign stating EXIT in raised characters and Braille and complying with ICC A117.1 shall be provided adjacent to each door to an area of refuge, an exterior area for assisted rescue, an exit stairway, an exit ramp, an exit passageway an the exit discharge. Refer to others docs for illuminated exit sign requirements. 6. ACCESSIBILITY: Required accessible elements shall be identified by the International Symbol of Accessibility (ISA) ___ at the following locations. 1. Accessible parking spaces required. 2. Accessible passenger loading zones. 3. Accessible rooms where multiple single-user toilet or bathing rooms are clustered at a single location. 4. Accessible entrances where not all entrances are accessible. 7. REST ROOM SIGNAGE: Required public rest room facilities shall be designated by a legible sign for each sex. Signs shall be readily visible and located near the entrance to each toilet facility. Provide ADA compliant tactile signs having Braille, regular copy and pictographs including wheelchair if applicable to be mounted 60" A.F.F. on wall at latch side of door. 8. ROOM DESIGNATIONS & IDENTIFICATION: Interior and exterior signs identifying permanent rooms and spaces shall be raised characters and Braille. Where pictograms are provided as designations of interior rooms and spaces, the pictograms shall have raised characters and Braille text descriptors. Exceptions: 1. Exterior signs that are not located at the door to the space they serve are not required to comply. 2. Temporary (seven days or less) signs are not required to comply. 9. Marketing Signage: Provide official building name & logo signage on building as approved by owner. 10. Other Jurisdiction Required Signage as required which could include: 1. FDC sign above exterior Fire Department Connection. DIVISION 22 – PLUMBING (Refer to Plumbing scope/documents & Utility requirements) GENERAL: 1. Provide a complete flexible shell building plumbing distribution and discharge system and coordinate requirements for all building equipment and fixtures. 2. All information shall be clearly documented and provided to owner and architect. Lines under floor slab shall be clearly documented. 3. All systems should be sized to include all future tenants. 221100 FACILITY WATER DISTRIBUTION 1. Provide a water distribution system complying with requirements of governing authorities. 2. Before any meters, provide a 2" supply line in valve room with 1 capped stub for each suite, spaced and capable of accepting the water utility meter at each stub. In addition, provide 1 house meter. And/or 3. Provide a continuous tap-able 2" supply line up in roof joists from meter in valve room the entire length of the building (side to side) 10' off the back wall of building. 4. Provide a 1" pipe x 6" stub at center of each of the tenant bays for future use. HOSE BIBS: Provide fully-recessed freeze-protected lockable exterior hose bibbs every 100' around building. Ensure one is close to trash enclosure. Also provide one freeze-protected hose bib centered on roof. Note: Main domestic water line and main sanitary sewerage line to run directly in-line above/below each other entire length of building. 221300 FACILITY SANITARY SEWERAGE 1. Provide a continuous tap-able discharge line under slab the entire length of building (side to side) approximately one third of overall building depth off the back wall of building, that would allow future service taps from any location within the building. Provide clean-outs and vent lines as required. 2. Drains - Provide floor drains in rest rooms, valve room, mech./elec. rooms & as required. 3. Materials, Traps, Cleanouts - Shall be provided as required. 4. Interceptors, Separators & Pumps - Shall be provided as required.Rev. #Issue / RevisionDate130% Set12-03-2021 ALL FIXTURES TO BE MOUNTED WITHIN ALLOWABLE RANGES AS INDICATED BY ADA ACCESSIBILITY GUIDELINES AND LOCAL CODES. (ALL MOUNTING HEIGHTS INDICATED ARE ABOVE FINISHED FLOOR LEVEL.) ALL GRAB BARS TO BE 1.25"-1.5" DIA. WITH GRIPPABLE SURFACE. SINK HEIGHTS SINK HEIGHTS W/MIRROR TOILET HEIGHTS URINAL HEIGHT PAPER TOWEL DISPENSER HEIGHT TOILET PAPER DISPENSER HEIGHT NAPKIN DISPOSAL HEIGHT BABY CHANGING STATION HEIGHT CLOTHES HOOKS HEIGHT ELECTRIC HAND DRYER34" MIN. 48" MAX.19"34"38" - 48"LATCHING MECHANISM54" MAX. TO27" MIN.9" MIN.17" MIN.34" MAX.6" MAX.34" MAX.40" MAX.39" - 41" 12" 42" MIN.39" - 41"MIN.18"17" - 19"36" 6" 18"33" - 36"17" - 19"17"25"34" MIN. 48" MAX.DRINKING FOUNTAIN SPOUT LOCATION (ANSI ICC A117.1-2009 FIG. 602.5a&b) TOE CLEARANCE (ANSI ICC A117.1-2009 FIG. 306.2) KNEE CLEARANCE (ANSI ICC A117.1-2009 FIG. 306.3) Shall install 2-Hi & Low or 1 that complies for people who use a wheelchair and standing person (2006 IBC Section 1109.5.1)36" MAX.15" MIN.43" MAX.15" MIN.CLEAR FLOOR 30" CLEAR FLOOR 30" CLEAR FLOOR 48"WHEELCHAIR36" MAXSTANDING38"-43"15" MIN. 5" MAX.ACTIVATION DEVICE48" MAX. TOPUSH PUSH 36" MAX.SPOUT HGT.43" MAX.SPOUT HGT.24" MIN.19" MAX.14" MIN.1 1/2" MIN.TP DISPENSER 42" MAX. 60" DIAMETER SPACE T-SHAPED SPACE FOR 180° TURNS MIN. 12" 36" MIN. MIN. 12"36" MIN.60" MIN.60" MIN. (a) (b) CORRIDOR OR OTHER CIRCULATION SPACE CARPET PILE THICKNESSWALKING PARALLEL TO A WALL SIGN OR OBSTRUCTION CANE RANGE WALL PERPENDICULAR TO A WALL EXAMPLE OF PROTECTION AROUND WALL-MOUNTED OBJECTS AND MEASUREMENTS OF CLEAR WIDTHS PROTRUDING OBJECTS HANGING ON WALL WITH LEADING EDGES ABOVE 27" WING WALLS DOWN TO FLOORADDITIONAL PROTECTION NOT REQUIRED BETWEEN WING WALLS (a)(b)(c) (d)80"4"x > 27"x < 27"ANY AMOUNT CLEAR WIDTH.27"CONT. PASSAGE36" MIN. CLEARPASSAGE32" MIN. CLR4"1/2" MAXMINIMUM CLEAR WIDTH FOR SINGLE WHEELCHAIR MINIMUM CLEAR WIDTH FOR TWO WHEELCHAIRS 36" MIN.60" MIN. 32" MIN.FOR MIN. CLEARANCE24" MAX.LATCH SIDE APPROACHES - SWINGING DOORS NOTE: ALL DOORS IN ALCOVES SHALL COMPLY WITH THE CLEARANCES FOR FRONT APPROACHES. NOTE: Y = 48" MINIMUM IF DOOR HAS CLOSER. PUSH SIDE NOTE: Y = 48" MINIMUM IF DOOR HAS BOTH A LATCH AND CLOSER. NOTE: Y = 54" MINIMUM IF DOOR HAS CLOSER. PULL SIDE PULL SIDE HINGE SIDE APPROACHES - SWINGING DOORS NOTE: X = 36" MINIMUM IF Y = 60"; X = 42" MINIMUM IF Y = 54". FRONT APPROACHES - SWINGING DOORS PUSH SIDE NOTE: X = 12" IF DOOR HAS BOTH A CLOSER AND A LATCH. PULL SIDE PUSH SIDE Y(b) (a) (c) 54" MIN.Y42" MIN.Y48" MIN.24" MIN. X 24" MIN.Y42" MIN.60"18"48"X X Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.NOT FOR CONSTRUCTIONSAA J:\2021\21113 Waukee Crossing Multi-Family - Hubbell\CAD-Arch\21113 Converge NW, Waukee, IA_Clubhouse.rvt12/3/2021 11:20:38 AMCONVERGE NWCLUBHOUSEWAUKEE, IOWA21113 G-011 ACCESSIBILITY REQUIREMENTS & GUIDELINES SP SCALE:1/4" = 1'-0"1 FIXTURE MOUNTING HEIGHT SCALE:1/4" = 1'-0"2 WHEELCHAIR TURNING SPACE SCALE:1/4" = 1'-0"6 PROTRUDING OBJECTS SCALE:1/4" = 1'-0"4 MINIMUM CLEAR WIDTHS SCALE:1/4" = 1'-0"3 MANEUVERING CLEARANCES @ DOORS ACCESSIBILITY GUIDELINES & REQUIREMENTS Code Referenced: 2010 ADA Standards for Accessible Design Dept. of Justice published revised regulations on September 15, 2010 to set minimum enforceable accessibility standards/requirements for newly designed & constructed or altered State and local government facilities, public accommodations, and commercial facilities after March 15, 2012. Code Referenced: Chapter 11, 2018 INTERNATIONAL BUILDING CODE (IBC) Buildings and facilities shall be designed and constructed to be accessible in accordance with this code and ICC/ANSI A117.1-2009 (Section 1101.2). 301 General 301.1 Scope. Floor and ground surfaces shall be stable, firm, and slip resistant and shall comply with 302. CHAPTER 3: BUILDING BLOCKS 302 Floor or Ground coverings 302.2 Carpet. Carpet or carpet tile shall be securely attached and shall have a firm cushion, pad, or pad. Carpet or carpet tile shall have a level loop, textured loop, level cut pile, or level cut/ uncut pile texture. Pile height shall be 1/2 inch (13 mm) maximum. Exposed edges of carpet shall be fastened to floor surfaces and shall have trim on the entire length of the exposed edge. Carpet edge trim shall comply with 303. 302.3 Openings. Openings in floor or ground surfaces shall not allow passage of a sphere more than 1/2 inch (13 mm) diameter except as allowed in 407.4.3, 409.4.3, 410.4, 810.5.3 and 810.10. Elongated openings shall be placed so that long dimension is perpendicular to the dominant direction of travel. 303 Changes in Level 303.1 General. Where changes in level are permintted in floor or ground surfaces, they shall comply with 303 EXCEPTIONS: 1. Animal containment areas shall not be required to comply with 303. 2. Areas of sports activity shall ot be required to comply with 303. 303.2 Vertical. Changes in level 1/4 inch (6.4 mm) high maximum shall be permitted to be vertical. 303.3 Beveled. Changes in level between 1/4 inch (6.4 mm) high minimum an 1/2 inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2. Advisory 303.3 Beveled. A change in level 1/2 inch (13 mm) is permitted to 1/4 inch (6.4 mm) vertical plus 1/4 inch (6.4 mm) beveled. However, in no case may the combined change in level exceed 1/2 inch (13 mm). changes in level exceeding 1/2 inch (13 mm) must comply with 405 (Ramps) or 406 (Curb Ramps). 303.4 Ramps. Changes in level greater than 1/2 inch (13 mm) high shall be ramped, and shall comply with 405 or 406. 304 Turning Space 304.1 General Turning space shall comply with 304. EXCEPTIONS: Slopes not steeper than 1:48 shall be permitted. 304.2 Floor or Ground Surfaces. Floor or ground surfaces of a turning space shall comply with 302. Changes in level are not permited. Advisory 304.2 Floor or Ground Surface Exception. As used in this section, the phrase "changes in lev el" refers to surfaces with slopes and to surfaces with abrupt rise exceeding that permitted in Section 303.3. Such changes in level are prohibited in required clear floor and ground spaces, turning spaces, and in similar spaces where people using wheelchairs and other mobility devices must park their mobility aids such as in wheelchair spaces, or maneuver those elements such as at doors, fixtures, and telephones. The exception permits slopes not steeper than 1:48. 304.3 Size. Turning space shall comply with 304.3.1 or 304.3.2. 304.3.1 Circular Space. Turning space shall be a space of 60 inches (1525 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with 306. 304.3.2 T-Shaped Space The turning space shall be a T-shaped space within a 60 inch (1525 mm) square minimum with arms and base 36 inches (915 mm) wide minimum. Each arm of the T shall be clear of obstructions 12 inches (304 mm) minimum in each direction and the base shall be clear of obstruction 24 inches (610 mm) minimum. The space shall be permitted to include knee and toe clearance complying with 306 only at the end of either the base or one arm. 304.4 Door Swing. Doors shall be permitted to swing into turning spaces. 305 Clear Floor or Ground Space 305.1 General Clear floor or ground space shall comply with 305. EXCEPTIONS: Slopes not steeper than 1:48 shall be permitted. 305.2 Floor or Ground Surfaces. Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted. 305.3 Size. The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum. 305.5 Position. Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element. 305.7.1 Forward Approach. Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). 305.4 Knee and Toe Clearance. Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with 306. 305.6 Approach. One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space. 305.7 Maneuvering Clearance. Where a clear floor space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with 305.7.1 and 305.7.2. 305.7.2 Parallel Approach. Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). 306 Knee and Toe Clearance 306.1 General. Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with 306. Additional space shall not be prohibited beneath an element but shall not be considered as part of the clear floor or ground space or turning space. Advisory 306.1 General. Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element. When determining clearance under an object for required turning or maneuvering space, care should be taken to ensure the space is clear of any obstructions. 306.2 Toe Clearance. 306.2.1 General. Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2. 306.2.2 Maximum Depth. Toe clearance shall extend 25 inches (635 mm) maximum under an element. 306.2.3 Minimum Required Depth. Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element. 306.2.4 Additional Clearance. Space extending greater than 6 inches (150 mm) beyond the available knee clearance at 9 inches (230 mm) above the finish floor or ground shall not be considered toe clearance. 306.2.5 Width. Toe clearance shall be 30 inches (760 mm) wide minimum. 306.3 Knee Clearance. 306.3.1 General. Space under an element between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground shall be considered knee clearance and shall comply with 306.3. 306.3.2 Maximum Depth. Knee clearance shall extend 25 inches (365 mm) maximum under an element at 9 inches (230 mm) above the finish floor or ground. 306.3.3 Minimum Required Depth. Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor or ground, and 8 inches (205 mm) deep minimum at 27 inches (685 mm) above the finish floor or ground. 306.3.4 Clearance Reduction. Between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground, the knee clearance shall be permited to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches (150mm) in height. 308 Reach Ranges 308.1 General. Reach ranges shall comply with 308. 308.2 Forward Reach. Advisory 308.1 General The folowing table provides guidance on reach ranges for children according to age where building elements such as hooks, lockers, or operable parts are designed for use primarily by children. These dimensions apply to either forward or side reaches. Accessible elements and operable parts designed for adult use or children over age 12 can be located outside these ranges but must be within the adule reach ranges required by 308. 308.2.1 Unobstructed. Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or ground. Children's Reach Ranges Forward or Side Reach Ages 3 and 4 Ages 5 through 8 Ages 9 through 12 High (maximum)36 in (915 mm)40 in (1015 mm)44 in (1120 mm) Low (minimum)20 in (510 mm)18 in (455 mm)16 in (405 mm) 308.2.2 Obstructed High Reach. Where a high reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction. The high forward reach shall be 48 inches (1120 mm) maximum where the reach depth is 20 inches (510mm) maximum. Where the reach depth exceeds 20 inches (150 mm) , the high reach shall be 44 inches (1120 mm) maximum and the reach depth shall be 25 inches (635 mm) maximum. 308.3 Side Reach. 308.3.1 Unobstructed. Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side shall be 15 inches (380 mm) minimum above the finish floor or ground. EXCEPTIONS: 1. An obstruction shall be permitted between the clear floor and ground space and the element where the depth of the obstruction is 10 inches (255 mm) maximum. 2. Operable parts of fuel dispensers shall be permitted to be 54 inches (1370 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs. 308.3.2 Unobstructed High Reach. Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum and the depth of the obstruction shall be 24 inches (610 mm) maximum. The high side reach shall be 48 inches (1220 mm) maximum for a reach depth of 10 inches (225 mm) maximum. Where the reach depth exceeds 10 inches (255 mm), the high side reach shall be 46 inches (117 mm) maximum for a reach depth of 24 inche (610 mm) maximum. EXCEPTIONS: 1. The top of washing machines and clothes dryers shall be permitted to be 36 inches (915 mm) maximum above the finish floor. 2. Operable parts of fuel dispensers shall be permitted to be 54 inches (1370 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs. 309 Operable Parts 309.1 General. Operable parts shall comply with 309. 309.2 Clear floor space. A clear floor space complying with 305 shall be provided. 309.3 Height. Operable parts shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be 5 pounds (22.2N) maximum. 307 Protruding Objects 307.1 General. Protruding objects shall comply with 307. 307.2 Protrusion Limits. Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into the circulation path. EXCEPTION: Handrails shall be permitted to protrude 4 1/2 inches (115 mm) maximum. Advisory 307.2 Protrusion Limits. When a cane is used and the element is in the detectable range, it gives a person suffecient time to detect the element with the cane before there is body contact. Elements located on circulation paths, including operable elements, must comply with requirements for protruding objects. For example, awnings and their supporting structures cannot reduce the minimum required vertical clearance. Similarly, casement windows, when open, cannot encroach more than 4 inches (100 mm) into the circulation path above 27 inches (685 mm). 307.3 Post-Mounted Objects. Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (685 mm) minimum and 80 inches (2030 mm) maximum above the finish floor or ground. Where a sign or other obstruction is mounted between posts or pylons and the clear distance between the posts or pylons is greater than 12 inches (305 mm), the lowest edge of such sign or obstruction shall be 27 inches (685 mm) maximum or 80 inches (2030 mm) minimum above the finish floor or ground. EXCEPTION: The sloping portions of handrails serving stairs and ramps shall not be required to comply with 307.3. EXCEPTION: Door closers and door stops shall be permited to be 78 inches (1980 mm) minimum above the finish floor or ground. 307.4 Vertical Clearance. Vertical clearance shall be 80 inches (2030 mm) high mimimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2030 mm) high. The leading edge of such guardrail or barrier shall be located 27 inches (685 mm) maximum above the finish floor or ground. 307.5 Required Clear Width Protruding objects shall not reduce the clear width required for accessible routes.Rev. #Issue / RevisionDate130% Set12-03-2021 WHSCALE: 1"=1'-0" EXTERIOR NON-RATED WALL 1 MANUFACTURED VENEER STONE OR BRICK (INSTALLED PER MFR.) (REFER TO ELEVATIONS FOR TYPE) OVER BUILDING WRAP OVER 1/2" EXTERIOR SHEATHING OVER 2x6 STUDS @ 16" O.C. W/ 5 1/2" FRICTION FIT BATT INSULATION (R21 MIN.), OVER 4-MIL VAPOR BARRIER OVER 5/8" GYP. BD. PROVIDE MOISTURE RESISTANT GYP. BD. @ ALL WET WALL LOCATIONS & ENTIRE RESTROOM, UNLESS NOTED OTHERWISE. SCALE: 1"=1'-0" EXTERIOR NON-RATED WALL 2 SIDING (INSTALLED PER MFR.) (REFER TO ELEVATIONS FOR TYPE) OVER BUILDING WRAP OVER 1/2" EXTERIOR SHEATHING OVER 2x6 STUDS @ 16" O.C. W/ 5 1/2" FRICTION FIT BATT INSULATION (R21 MIN), OVER 4-MIL VAPOR BARRIER OVER 5/8" GYP. BD. PROVIDE MOISTURE RESISTANT GYP. BD. @ ALL WET WALL LOCATIONS & ENTIRE RESTROOM, UNLESS NOTED OTHERWISE. SCALE: 1"=1'-0" INTERIOR NON-RATED WALL 3 2x4 STUDS @ 16" O.C. W/ 3 1/2" FRICTION FIT SOUND BATT INSUL., W/ ONE LAYER 1/2" GYP. BD. BOTH SIDES. PROVIDE MOISTURE RESISTANT GYP. BD. @ ALL WET WALL LOCATIONS & ENTIRE RESTROOM. UNLESS NOTED OTHERWISE. SCALE: 1"=1'-0" INTERIOR NON-RATED WALL 4 2x6 STUDS @ 16" O.C. W/ 5 1/2" FRICTION FIT SOUND BATT INSULATION, W/ ONE LAYER 5/8" GYP. BD. BOTH SIDES. PROVIDE MOISTURE RESISTANT GWB @ ALL WET WALL LOCATIONS & ENTIRE RESTROOM. UNLESS NOTED OTHERWISE. FGF FLUSH DOOR WITH FULL GLASS LITE FLUSH DOOR W/ INSULATED CORE SCHED. SEESCHED. SEE SCHED.SEESCHED.SEEAS REQUIRED 2" 2" AS REQ. 2" 7' - 6" 2" 11' - 0" 1AS REQUIRED 2" 2" AS REQ. 2" 2AS REQUIRED 2" 2" AS REQ. 2" 8" 2" 4' - 2" 3 A1' - 0" 6' - 2" 5' - 0" D1' - 0" 6' - 2" 4' - 0" B7' - 2" 2' - 0" 5' - 0" FIBERGLASS FIXED WINDOW FIBERGLASS FIXED WINDOW FIBERGLASS FIXED WINDOW7' - 2"9' - 2"7' - 2"E7' - 2" 1' - 0" 4' - 0" FIBERGLASS FIXED WINDOW8' - 2"C7' - 2" 2' - 0" 6' - 4" FIBERGLASS FIXED WINDOW9' - 2"M-201 1 M-2013 M-201 2 M-201 4 POOL GATE, SPECIFIC HARDWARE, TBD POOL GATE, SPECIFIC HARDWARE, TBD POSTAL PACKAGE LOCKER. COORDINATE SIZE WITH POSTAL.FURN.FILES13'-0"68'-6"23'-0"32'-8"32'-0"13'-0"18'-0"10'-11" 1497 SF POOL -- UTIL. 110 15'-0" 18'-0" 15'-0" 24/7 CORRIDOR 109 STOR 103 POOL EQUIP./ STORAGE 106 A-201 4 A-201 1 A-2012 A-201 3 A-401 9 10 A-401 1 A-401 6 OFFICE 102 RR 105 RR 104 FITNESS 111 COMMUNITY 101 FURN.34'-7"20'-5" 8'-9 5/8" 7'-8" 21'-6"31'-0"21'-6"34'-0"29'-0"52'-8" 7'-3 1/4"4 3/4"15'-4" 5'-1 3/4" 4 3/4"27'-10" 4 3/4" 9'-10 1/2" 4 3/4" 6'-8 1/2" 6 3/4" 6'-4" 8'-4 7/8" 6 3/4" 8'-8 1/2"4 3/4"9'-10 7/8" 20'-5 3/4" 4 3/4" 27'-10" 5 1/2" 2'-11 1/4" 4 3/4" 20'-5 3/4" 13'-7 1/4"7'-10"4 3/4"5'-0"4 3/4"14'-10 1/4"14'-7 1/2"4 3/4"5'-7"4 3/4"5'-5 1/2" 27'-6 1/4"12'-6 3/4"1 2 1 1 2 12 2 2 1 2 1 2 1 2 1 21 1 2 2 BELOW ABOVE BELOW ABOVE BELOW ABOVE BELOW ABOVEBELOW ABOVE BELOW ABOVE BELOW ABOVE BELOW ABOVE D D D B A D D D E E BBBB E E E 2'-6" 4'-0" 2'-3" 4'-0" 2'-3" 4'-0" 2'-6" 31'-0" 2'-8" 4'-0"2'-1" 4'-0" 2'-1" 4'-0" 2'-8" 21'-6" 3'-11 1/8" 21'-11 1/2" 5'-1 3/8" 21'-6" 4'-6" 5'-0" 2'-3" 6'-4" 2'-3" 5'-0" 5'-8"21'-0"4'-5 1/2" 15'-6 1/2" 4'-0" 3'-3" 4'-0" 2'-9"17'-0" 3'-4"8"20'-5" 3'-4" 5'-3"16'-0" 3'-2" 1'-0" 14'-5" 2'-0" 4'-0" 2'-0" 4'-0" 2'-0" 4'-0" 2'-5" 102 105104 103 107108 109.2 101.2111110 101.1 109.1 106 MEN'S RR 108 WOMENS RR 107 3' - 2" 5' - 0" 4' - 4" 5' - 0" 4' - 4" 5' - 0" 4' - 4" 5' - 0" 16' - 6" A B C A A A A Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.NOT FOR CONSTRUCTIONSAA J:\2021\21113 Waukee Crossing Multi-Family - Hubbell\CAD-Arch\21113 Converge NW, Waukee, IA_Clubhouse.rvt12/3/2021 11:20:30 AMCONVERGE NWCLUBHOUSEWAUKEE, IOWA21113 A-101 FLOOR PLAN SP 1.REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2.ALL SITE INFO, FURNITURE, FIXTURES AND EQUIPMENT SHOWN SHOULD BE CONSIDERED CONCEPTUAL AND MAY HAVE BE PROVIDED FOR COORDINATION PURPOSES ONLY. REFER TO CIVIL, FIRE SUPPRESSION, PLUMBING, MECHANICAL, ELECTRICAL, COMMUNICATIONS, ELECTRONIC SAFETY & SECURITY DOCUMENTS &/OR CONSULTANTS FOR SPECIFIC DESIGN INFORMATION & REQUIREMENTS. 3.DIMENSIONS ARE TO FACE OF FINISH MATERIAL OR CENTER OF STRUCTURE UNLESS OTHERWISE SPECIFIED. 4.ALL CONDUITS, PIPES, WIRING, ROUGH-IN, ETC. SHOULD BE HELD AS TIGHT AS POSSIBLE TO THE ROOF OR FLOOR DECK OR SHOULD BE KEPT WITHIN INTERIOR WALL CAVITIES. NOTHING SHALL BE BELOW THE BOTTOM EDGE OF MAIN BUILDING FRAMES, NOTHING SHALL BE EXPOSED IN FINISHED SPACES, NOTHING SHALL PREVENT A SMOOTH CONTINUOUS FINISHED WALL OR CEILING AS NOTED ON THE DRAWINGS AND NO PLUMBING RAN IN EXTERIOR WALLS UNLESS PRIOR APPROVAL IS GRANTED BY THE ARCHITECT OR OWNER. PLACEMENT COORDINATION BETWEEN TRADES IS REQUIRED. 5.INSTALL VERTICAL EXPANSION JOINT MINIMAL AT COLUMN/GRID LINES AND AT THE HEAD OF DOOR JAMBS/OPENINGS OR AS OTHERWISE NOTED OR WHERE REQUIRED PER STANDARD MATERIAL PRACTICE TO REDUCE STRESS CRACKING. NO CONTROL JOINT/EXPANSION JOINT IN LOAD BEARING AREAS, STAY AWAY 2'-6" MIN. 6.CAULK & SEAL ALL CONTROL-EXPANSION, SAWCUT JOINTS AT ALL INTERIOR & EXTERIOR MASONRY & CONCRETE. 7.PROVIDE LOWER LEVEL AND/OR UNDERFLOOR DRAINAGE SYSTEM TO REDUCE HYDROSTATIC UPLIFT AND PROTECT AGAINST MOISTURE SEEPAGE. PROVIDE FOUNDATION WALL DRAINAGE SYSTEM TO REDUCE LATERAL PRESSURES AND PROTECT AGAINST MOISTURE SEEPAGE. BOTH SYSTEMS SHALL OUTLET TO APPROPRIATE RELIEF. 8.PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM BUILDING WITHOUT PONDING OF WATER ADJACENT TO BUILDING OR ON PAVEMENTS. GENERAL FLOOR PLAN NOTES Rev. #Issue / RevisionDate130% Set12-03-2021VERTICAL ASSEMBLIES DOOR & FRAME SCHEDULE DOOR NO.ROOM NAME DOOR FRAME HARDWARE REMARKS (ALSO SEE NOTES)TYPE PAIR WIDTH HEIGHT MAT'L TYPE RATING MAT'L CLOSER PANIC THLD 101.1 COMMUNITY FG Yes 6' - 0" 7' - 0" ALUMINUM 1 - ALUMINUM E.STRIKE/ CARD READER, ADA DOOR OPENER 101.2 COMMUNITY FG No 3' - 0" 7' - 0" H. METAL 2 - H. METAL Yes Yes No E.STRIKE/ CARD READER 102 OFFICE FG No 3' - 0" 7' - 0" ALUMINUM 3 - ALUMINUM No No No OFFICE LOCK 103 STOR F No 3' - 0" 7' - 0" H. METAL 1 - H. METAL Yes No No STORAGE LOCK 104 RR F No 3' - 0" 7' - 0" ALUMINUM 1 - ALUMINUM Yes No No PRIVACY LOCK 105 RR F No 3' - 0" 7' - 0" ALUMINUM 1 - ALUMINUM Yes No No PRIVACY LOCK 106 POOL EQUIP./ STORAGE FG No 3' - 0" 7' - 0" H. METAL 1 -H. METAL Yes No Yes STORAGE LOCK 107 WOMENS RR F No 3' - 0" 7' - 0" H. METAL 1 - H. METAL Yes No No PUSH/PULL 108 MEN'S RR F No 3' - 0" 7' - 0" H. METAL 1 - H. METAL Yes No No PUSH/PULL 109.1 24/7 CORRIDOR FG No 3' - 0" 7' - 0" H. METAL 1 - H. METAL Yes No Yes E.STRIKE/ CARD READER, ADA DOOR OPENER 109.2 24/7 CORRIDOR FG No 3' - 0" 7' - 0" H. METAL 2 - H. METAL Yes Yes No E.STRIKE/ CARD READER, ADA DOOR OPENER 110 UTIL. F No 3' - 0" 7' - 0" H. METAL 1 - H. METAL Yes No No STORAGE LOCK 111 FITNESS FG No 3' - 0" 7' - 0" H. METAL 2 - H. METAL Yes No No PASSAGE DOOR TYPESFRAME TYPES 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL LOCKS SHALL BE REMOVABLE CYLINDER TYPE, MASTER KEYED(CONTRACTOR TO COORDINATE KEYING WITH OWNER) 3. ALL HARDWARE TO BE HEAVY DUTY COMMERCIAL GRADE BRUSHED CHROME FINISH. BRUSHED STAINLESS STEEL IS AN ACCEPTABLE ALTERNATIVE FINISH. 4. DOORS TO ROOMS WITH ELECTRICAL SERVICES OF 800 AMPS OR GREATER WILL REQUIRE PANIC EXIT HARDWARE ON ALL DOORS. 5. ALL EXTERIOR DOORS: (UNLESS OTHERWISE NOTED) • SHALL BE FULLY INSULATED, HEAVY-DUTY CONSTRUCTION. • FRAMES SHALL BE HEAVY-DUTY HOLLOW METAL CONSTRUCTION. • SHALL BE WEATHER-TIGHT, I.E. THRESHOLD, WEATHERSTRIPPING, SWEEP. • SHALL HAVE LEVER STYLE ADA DOOR HANDLES AND/OR PULLS. • SHALL HAVE LOCKING DEVICES. PANIC HARDWARE AT REQUIRED EXITS. • SHALL HAVE HEAVY DUTY SECURITY HINGES, WITH NON-REMOVABLE PINS. • SHALL HAVE AUTOMATIC DOOR CLOSERS. • SHALL HAVE CORRESPONDING DOORSTOPS (WALL OR OVERHEAD MOUNTED). • SHALL HAVE ALARM HARDWARE. • WITH RATING SHALL HAVE CLOSERS, THRESHOLDS, GASKETING AND COMPLETE RATED HARDWARE AS REQUIRED. • SHALL HAVE SPECIFIC HARDWARE AS NOTED ON DOOR SCHEDULE. 6. ALL INTERIOR DOORS: (UNLESS OTHERWISE NOTED) • SHALL BE SOLID-CORE, WOOD (STYLE AS SCHEDULED). • SHALL BE HEAVY DUTY HOLLOW REINFORCED METAL CONSTRUCTION. • DOORS BETWEEN FULL HVAC AND REDUCED HVAC SPACES SHALL BE FULLY INSULATED. • FRAMES SHALL BE 3/4" SOLID WOOD CONSTRUCTION. • SHALL HAVE LEVER STYLE ADA DOOR HANDLES AND/OR PULLS. • SHALL HAVE HEAVY DUTY HINGES. • SHALL HAVE SILENCERS; WHERE INSULATED SHALL HAVE THRESHOLD, WEATHERSTRIPPING, SWEEP. • SHALL HAVE CORRESPONDING DOORSTOPS (WALL OR OVERHEAD MOUNTED). • WITH LOBBY ACCESS SHALL HAVE CLOSERS, PANIC & ALARM HARDWARE, LOCKING DEVICES. • WITH RATING SHALL HAVE CLOSERS, THRESHOLDS, GASKETING AND COMPLETE RATED HARDWARE AS REQUIRED. • SHALL HAVE CLOSERS, LOCKS & SPECIFIC HARDWARE AS NOTED ON DOOR SCHEDULE. 7. ALL GLASS: (UNLESS OTHERWISE NOTED) • IN INTERIOR DOORS AND FRAMES TO BE 1/4" CLEAR. • IN EXTERIOR DOORS AND FRAMES TO BE INSULATED & MATCH IN APPEARANCE. • SHALL BE TEMPERED, LAMINATED AND/OR RATED WHERE REQUIRED BY AUTHORITIES. 8. REFER TO MEP DOCS OR MEP SCOPE FOR CARD READER / SECURITY SYSTEM REQUIREMENTS. 9. ALL HARDWARE IS TO BE APPROVED BY OWNER/ ARCHITECT. 10. LATCH PLATES FOR DOOR LOCKS AND DEADBOLTD SHALL BE INSTALLED WITH LAG SCREWS, OR SIMILAR, AT LEAST 3 INCHES IN LENGTH, AND CAPABLE OF ATTACHING THROUGH THE DOOR FRAME AT LEAST 1 1/2 INCHES INTO THE STUD WALL FRAMING. GENERAL DOOR, FRAME & HARDWARE NOTES: 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL LOCKS SHALL BE REMOVABLE CYLINDER TYPE, MASTER KEYED(CONTRACTOR TO COORDINATE KEYING WITH OWNER) 3. ALL HARDWARE TO BE HEAVY DUTY COMMERCIAL GRADE BRUSHED CHROME FINISH. BRUSHED STAINLESS STEEL IS AN ACCEPTABLE ALTERNATIVE FINISH. 4. DOORS TO ROOMS WITH ELECTRICAL SERVICES OF 800 AMPS OR GREATER WILL REQUIRE PANIC EXIT HARDWARE ON ALL DOORS. 5. ALL EXTERIOR DOORS: (UNLESS OTHERWISE NOTED) • SHALL BE FULLY INSULATED, HEAVY-DUTY CONSTRUCTION. • FRAMES SHALL BE HEAVY-DUTY HOLLOW METAL CONSTRUCTION. • SHALL BE WEATHER-TIGHT, I.E. THRESHOLD, WEATHERSTRIPPING, SWEEP. • SHALL HAVE LEVER STYLE ADA DOOR HANDLES AND/OR PULLS. • SHALL HAVE LOCKING DEVICES. PANIC HARDWARE AT REQUIRED EXITS. • SHALL HAVE HEAVY DUTY SECURITY HINGES, WITH NON-REMOVABLE PINS. • SHALL HAVE AUTOMATIC DOOR CLOSERS. • SHALL HAVE CORRESPONDING DOORSTOPS (WALL OR OVERHEAD MOUNTED). • SHALL HAVE ALARM HARDWARE. • WITH RATING SHALL HAVE CLOSERS, THRESHOLDS, GASKETING AND COMPLETE RATED HARDWARE AS REQUIRED. • SHALL HAVE SPECIFIC HARDWARE AS NOTED ON DOOR SCHEDULE. 6. ALL INTERIOR DOORS: (UNLESS OTHERWISE NOTED) • SHALL BE SOLID-CORE, WOOD (STYLE AS SCHEDULED). • SHALL BE HEAVY DUTY HOLLOW REINFORCED METAL CONSTRUCTION. • DOORS BETWEEN FULL HVAC AND REDUCED HVAC SPACES SHALL BE FULLY INSULATED. • FRAMES SHALL BE 3/4" SOLID WOOD CONSTRUCTION. • SHALL HAVE LEVER STYLE ADA DOOR HANDLES AND/OR PULLS. • SHALL HAVE HEAVY DUTY HINGES. • SHALL HAVE SILENCERS; WHERE INSULATED SHALL HAVE THRESHOLD, WEATHERSTRIPPING, SWEEP. • SHALL HAVE CORRESPONDING DOORSTOPS (WALL OR OVERHEAD MOUNTED). • WITH LOBBY ACCESS SHALL HAVE CLOSERS, PANIC & ALARM HARDWARE, LOCKING DEVICES. • WITH RATING SHALL HAVE CLOSERS, THRESHOLDS, GASKETING AND COMPLETE RATED HARDWARE AS REQUIRED. • SHALL HAVE CLOSERS, LOCKS & SPECIFIC HARDWARE AS NOTED ON DOOR SCHEDULE. 7. ALL GLASS: (UNLESS OTHERWISE NOTED) • IN INTERIOR DOORS AND FRAMES TO BE 1/4" CLEAR. • IN EXTERIOR DOORS AND FRAMES TO BE INSULATED & MATCH IN APPEARANCE. • SHALL BE TEMPERED, LAMINATED AND/OR RATED WHERE REQUIRED BY AUTHORITIES. 8. REFER TO MEP DOCS OR MEP SCOPE FOR CARD READER / SECURITY SYSTEM REQUIREMENTS. 9. ALL HARDWARE IS TO BE APPROVED BY OWNER/ ARCHITECT. 10. LATCH PLATES FOR DOOR LOCKS AND DEADBOLTD SHALL BE INSTALLED WITH LAG SCREWS, OR SIMILAR, AT LEAST 3 INCHES IN LENGTH, AND CAPABLE OF ATTACHING THROUGH THE DOOR FRAME AT LEAST 1 1/2 INCHES INTO THE STUD WALL FRAMING. GENERAL DOOR, FRAME & HARDWARE NOTES:1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. SEALANT AND BACKER ROD AT PERIMETER FRAMING. VERIFY SYSTEM WEEPS ARE KEPT CLEAR, FREE OF SEALANT AND DEBRIS. 3. ADDITIONAL FRAMING, STRUCTURAL SUPPORTS AND/OR BRACING SHALL BE IDENTIFIED BY THE WINDOW SUB-CONTRACTOR PRIOR TO BIDDING & INSTALLATION. 4. PROVIDE TIGHT FITTING SCREENS OF NOT LESS THAN 16 MESH PER INCH AT ALL OPERABLE WINDOWS. 5. IN RESIDENTIAL OCCUPANCIES WHERE THE OPENING OF THE WINDOW SILL PORTION OF AN OPERABLE WINDOW IS LOCATED MORE THAN 72”ABOVE FINISHED GRADE OR OTHER SURFACE BELOW, ONE OF THE FOLLOWING IS REQUIRED: A. THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE AT A HEIGHT NOT LESS THAN 36”ABOVE FINISHED FLOOR SURFACE OR THE ROOM IN WHICH THE WINDOW IS LOCATED. B. OPERABLE SECTION OF WINDOWS SHALL NOT PERMIT OPENINGS THAT ALLOW PASSAGE OF A 4”DIAMETER SPHERE WHERE SUCH OPENINGS ARE LOCATED WITHIN 36”OF THE FINISHED FLOOR. C. WINDOW OPENING CONTROL DEVICES SHALL COMPLY WITH ASTM F 2090. THE WINDOW OPENING CONTROL DEVICE, AFTER OPERATION TO RELEASE THE CONTROL DEVISE ALLOWING THE WINDOW TO FULLY OPEN, SHALL NOT REDUCE THE MINIMUM NET CLEAR OPENING AREA OF THE WINDOW UNIT TO LESS THAN THE AREA REQUIRED. GENERAL WINDOW TYPE NOTES: WINDOW TYPES 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL ASSEMBLY DESCRIPTIONS NOTED ARE GENERAL AND FOR COORDINATION PURPOSES ONLY, THE DESIGNATED ASSEMBLY SHOULD BE FOLLOWED EXACTLY AS REQUIRED. ANY DISCREPANCIES BETWEEN THE GENERAL DESCRIPTIONS AND THE DESIGNATED ASSEMBLY NOTED SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY BEFORE ANY WORK IS PERFORMED. 3. COORDINATE WITH ALL CORRESPONDING DISCIPLINES AND PRODUCTS THAT ARE PART OF OR RELYING ON EACH SYSTEM OR ASSEMBLY. 4. ALL GYPSUM BOARD: • SURFACES & LAYERS SHALL BE FINISHED PER THE RECOMMENDED LEVELS OF GYPSUM BOARD FINISH 1-5 AS REQUIRED FOR FINAL FINISH OR CODE REQUIREMENTS. • PROVIDE MOISTURE RESISTANT GYPSUM BOARD AT ALL WET WALL LOCATIONS AND ENTIRE REST ROOM, TYP. • PROVIDE INTEGRAL METAL REINFORCED GYPSUM BOARD CORNERS, TYP. • PROVIDE VERTICAL & HORIZONTAL EXPANSION JOINTS AS REQUIRED TO PREVENT CRACKS IN WALLS. TRY TO LOCATE AT COLUMN/GRID LINES AND AT THE HEAD OF DOOR JAMBS/OPENINGS OR AS OTHERWISE NOTED, 24’ MAXIMUM, OR WHERE REQUIRED PER STANDARD MATERIAL PRACTICE TO ELIMINATE STRESS CRACKING. 5. TIGHTLY WRAPPED WITH GYPSUM BOARD OVER STUDS, TYP. U.O.N. ALL INTERIOR STEEL BEAMS FALLING BELOW FINISHED CEILING HEIGHTS SHALL BE TIGHTLY WRAPPED WITH GYPSUM BOARD OVER STUDS, TYP. U.O.N. 6. ALL PENETRATIONS INTO OR THROUGH FIRE-RESISTIVE-RATED ASSEMBLIES SHALL BE PROTECTED BY APPROVED PENETRATION FIRESTOP SYSTEMS DESIGNED TO RESIST THE PASSAGE OF FIRE &/OR SMOKE FOR A TIME PERIOD NOT LESS THAN THE REQUIRED FIRE-RESISTANCE RATING WHICH IT IS INSTALLED. 7. ALL JOINTS INSTALLED IN OR BETWEEN FIRE-RESISTIVE-RATED WALLS, FLOORS OR FLOOR/CEILING ASSEMBLIES AND ROOFS OR ROOF/CEILING ASSEMBLIES SHALL BE PROTECTED BY APPROVED FIRE-RESISTANT JOINT SYSTEM DESIGNED TO RESIST THE PASSAGE OF FIRE FOR A TIME PERIOD NOT LESS THAN THE REQUIRED FIRE-RESISTANCE RATING WHICH IT IS INSTALLED. 8. ALL OPENINGS INSTALLED IN FIRE-RESISTIVE-RATED ASSEMBLIES SHALL BE PROTECTED BY APPROVED FIRE-RESISTANCE-RATED OPENING PROTECTIVES DESIGNED & LABELED TO RESIST THE PASSAGE OF FIRE & SMOKE FOR A TIME PERIOD NOT LESS THAN THE REQUIRED FIRE-RESISTANCE RATING WHICH IT IS INSTALLED. 9. INSTALL GYPSUM BOARD/GYPCRETE PRIOR TO SETTING TUBS/SHOWERS AT RATED ASSEMBLIES IN ORDER TO MAINTAIN REQUIRED RATING. 10. ALL WOOD FRAMING MEMBERS, INCLUDING WOOD SHEATHING, THAT REST ON THE EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8” FROM EXPOSED EARTH AND ALL WOOD IN DIRECT CONTACT WITH MASONRY, CONCRETE, EARTH OR MATERIAL THAT RETAINS MOISTURE SHALL BE OF NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. 11. PROVIDE ADEQUATE WOOD BLOCKING FOR MILLWORK, FIXTURES, EQUIPMENT, PLUMBING FIXTURES AND ACCESSORIES, ELECTRIC PANELS, ROOF ACCESS LADDERS, FUTURE &/OR BY OWNER ITEMS, ETC. 12. PROVIDE BRACING AT TOP OF WALLS AS NEEDED AT LOWER PARTITION WALLS THAT ARE FREE STANDING AND DON'T EXTEND TO STRUCTURE ABOVE. 13. ROOF SYSTEM SHOULD BE INSTALLED SUCH THAT A THERMAL BARRIER IS NOT REQUIRED. 14. TREATED SILL PLATE SET ON SILL SEALER AT ALL CONCRETE, TYP. GENERAL ASSEMBLY NOTES NORTH SCALE:1/8" = 1'-0"1 FLOOR PLAN FINISHED FLOOR 0" TRUSS BEARING 10' - 1 1/8" A D D DADDD B BC 101.1 STN STN STN FCB FCB FCB FCB FCB FCP BRK RF FAS FCT FCT FCT FINISHED FLOOR 0" TRUSS BEARING 10' - 1 1/8" 106 A A A A BBBB RF FCPFCP BRK FAS FINISHED FLOOR 0" TRUSS BEARING 10' - 1 1/8" E E 109.1 FCP FCB RF STNBRKSTN FCT FAS FINISHED FLOOR 0" TRUSS BEARING 10' - 1 1/8" E E E 109.2 FCT STN FCT FCT FAS FAS RF FCB STN BRK FCP Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.NOT FOR CONSTRUCTIONSAA J:\2021\21113 Waukee Crossing Multi-Family - Hubbell\CAD-Arch\21113 Converge NW, Waukee, IA_Clubhouse.rvt12/3/2021 11:20:31 AMCONVERGE NWCLUBHOUSEWAUKEE, IOWA21113 A-201 EXTERIOR ELEVATIONS SP 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL CONDUIT RUNS & SERVICE LINES SHALL BE GROUPED TOGETHER IN A NEAT & ORDERLY MANNER AND SHOULD PENETRATE THE WALL AT THE LOWEST POINT AND ARE NOT TO RUN OVER THE TOP OF PARAPET. ALL OTHER CONDUITS & JUNCTION BOXES FOR EXTERIOR FIXTURES & EQUIPMENT SHALL BE FULLY CONCEALED WITHIN THE BUILDING CONSTRUCTION. 3. ALL HORIZONTAL TRANSITIONS BETWEEN DIFFERENT MATERIALS SHALL BE FLASHED CONTINUOUS FROM UP BEHIND UPPER MATERIAL AND EXTEND OVER TO EXTERIOR FACE OF LOWER MATERIAL WITH DRIP EDGE. 4. ANY RETURNS OR BLIND ELEVATIONS NOT SHOWN SHALL BE SIMILAR IN MATERIAL AND MAKEUP TO ADJACENT CONDITIONS OR OTHER SIMILAR CONDITIONS. 5. NO EXPOSED MASONRY/MATERIAL CORES. MASONRY RETURNS AT WINDOWS/OPENINGS ARE REQUIRED IF FRAMING IS NOT DEEP ENOUGH TO PROVIDE CLOSURE AT THE BACKSIDE OF MASONRY FOR AN EFFECTIVELY SEALED JOINT. 6. INSTALL VERTICAL EXPANSION JOINTS PER STRUCTURAL OR MINIMAL AT COLUMN/GRID LINES AND AT THE HEAD OF DOOR JAMBS/OPENINGS OR AS OTHERWISE NOTED OR WHERE REQUIRED PER STANDARD MATERIAL PRACTICE TO REDUCE STRESS CRACKING. NO CONTROL JOINT/EXPANSION JOINT AT MAIN STRUCTURAL BEARING LOCATIONS. VERIFY JOINTS WITH ARCHITECT. 7. CAULK & SEAL ALL TRANSITION-CONTROL-EXPANSION AT ALL EXTERIOR MATERIALS. 8. PROVIDE CAST REGLETS JUST IN FROM THE OUTER EDGE ON UNDERSIDE OF FACE MATERIAL OR DRIP EDGE AT ALL OVERHANGS & SOFFITS. 9. INSULATE AND SEAL TO ENSURE ADEQUATE AIR INFILTRATION BARRIER AROUND ALL EXTERIOR PENETRATIONS TO PREVENT WATER AND SPRINKLER PIPE FREEZING. 10. WHERE EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF PAVING TO BE 1/4" LOWER THAN INTERIOR FINISH FLOOR, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. WHERE DOOR STOOP, 48" OUT FROM DOOR 1:48(2%) MAX. SLOPE, AFTER 48" AWAY FROM DOOR 1:20(5%) MAXIMUM SLOPE TO PUBLIC WAY. (REFER TO CIVIL) 11. WHERE NO EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF FINISHED LANDSCAPE A MINIMUM OF 4" BELOW INTERIOR FINISH FLOOR AND 4”BELOW EXTERIOR WALL FLASHING/WEEPS, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. (REFER TO CIVIL) 12. ADDRESS SHALL BE PROVIDED ON STREET SIDE OF BUILDING AND ON MONUMENT SIGN. NUMBERS A MINIMUM 5 INCH CONTRASTING COLOR NUMBERS WITH MINIMUM 1/2" STROKE. 13. IF ANY SIGNAGE OR SIGN BASE IS SHOWN IT IS FOR REFERENCE ONLY, FINAL DESIGNS AND/OR ALLOWANCES SHALL BE DETERMINED WITH APPROVED SIGNAGE PERMIT(S). ACTUAL DETAILS & DIMENSIONS MAY VARY AND ARE SUBJECT TO CHANGE. ALL DRAWINGS ARE SUBJECT TO AUTHORITY HAVING JURISDICTION APPROVAL. SIGNAGE SHOWN DOES NOT REPRESENT ALLOWABLE SIGNAGE PERMITTING/APPROVAL OF ALL SIGNAGE PER CURRENT CITY ORDINANCE BY OTHERS. GENERAL EXTERIOR ELEVATION NOTES: EXTERIOR MATERIAL LEGEND MAT. LABEL MATERIAL DESCRIPTION BRK MERIDIAN THIN BRICK - AMARO; NATURAL MORTAR FAS PREFINISHED METAL FASCIA, COLOR - WHITE FCB FIBER CEMENT LAP SIDING, 6" REVEAL, COLOR - WHITE FCP FIBER CEMENT PANEL SMOOTH SIDING, COLOR - DARK GRAY FCT 5/4 HARDIE TRIM BOARD, SMOOTH, COLORPLUS, ARCTIC WHITE RF ARCHITECTURAL ASPHALT ROOFING SHINGLES, COLOR- CHARCOAL SF T.B. ALUMINUM STOREFRONT FRAMING: CLEAR ANODIZED FINISH STN MANUFACTURED VENEER STONE (INSTALLED PER MFR.) VIS 1” INSULATED VISION GLASS: CLEAR W/ LOW E COATING • H. METAL MAN DOORS & FRAMES: PAINTED TO MATCH ADJACENT MATERIAL. • GUTTERS AND DOWNSPOUTS: METAL PREFINISHED TO MATCH ADJACENT MATERIAL. • FASCIA AND SOFFIT: METAL PREFINISHED TO MATCH ROOF COLOR. • CAULKS AND SEALANTS: COLOR MATCHED TO ADJACENT MATERIAL.Rev. #Issue / RevisionDate130% Set12-03-2021SCALE:3/16" = 1'-0"4 EAST ELEVATION SCALE:3/16" = 1'-0"3 WEST ELEVATION SCALE:3/16" = 1'-0"2 SOUTH ELEVATION SCALE:3/16" = 1'-0"1 NORTH ELEVATION 7" 5' - 0" 1" 3' - 0" 5" 4' - 4" 1' - 10" WOMENS RR 107 MEN'S RR 108 8' - 5"7"8' - 8"A-401 3 5 1071085' - 11"5"5' - 4"5"5' - 8"A-401 2 4 104105A-401 7 8 RR 104 RR 105 3' - 6"1' - 8"2' - 10"2' - 10"3' - 3"1' - 9" 1" 2' - 0"2' - 1" 2' - 6" 3' - 0" 1' - 6"1' - 3" OPENMAX.2' - 10"6"3' - 6"1' - 4"4"MAX.2' - 10"8' - 0"2' - 6" 2" 1' - 1" 3" 2' - 0" 5' - 0" 1" 3' - 0" 5" 4' - 4" 1' - 10" 16"-18"MAX.2' - 10"4"MAX.3' - 4"4"MAX.2' - 10"MAX.3' - 4"1' - 10" 4' - 4" 5" 3' - 0" 1" 5' - 0" 16"-18"MAX.2' - 10"4"MAX.3' - 4"4"MAX.2' - 10"MAX.3' - 4"MIN. 1' - 3" 16"-18"MAX.2' - 10"3' - 4"Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.NOT FOR CONSTRUCTIONSAA J:\2021\21113 Waukee Crossing Multi-Family - Hubbell\CAD-Arch\21113 Converge NW, Waukee, IA_Clubhouse.rvt12/3/2021 11:20:35 AMCONVERGE NWCLUBHOUSEWAUKEE, IOWA21113 A-401 ENLARGED PLANS & INTERIOR ELEVATIONS SP 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL PLUMBING FIXTURES SHOWN ON THIS SHEET IS PROVIDED FOR COORDINATION PURPOSES ONLY. REFER TO PLUMBING DOCUMENTS FOR SPECIFIC DESIGN INFO. 3. ALL REST ROOMS, FIXTURES & ACCESSORIES SHALL BE COMMERCIAL GRADE AND SHALL COMPLY WITH THE REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT. 4. PROVIDE ADEQUATE BLOCKING FOR ALL REST ROOM FIXTURES AND EQUIPMENT. 5. ADD GFI POWER UNDER SINKS OR AROUND WATER CLOSETS IF AUTO- CONTROLS. 6. FIXTURE & ACCESSORY MOUNTING HEIGHTS ARE AS FOLLOWS: • DRINKING FOUNTAIN & WATER COOLER: • SPOUT HEIGHT: NO HIGHER THAN 36" AFF, • CONTROLS HEIGHT: SEE BELOW. • WATER CLOSET HEIGHT: 17"-19" TO TOP OF TOILET SEAT. • URINAL RIM HEIGHT: 17" AFF. • GRAB BAR CENTER MOUNTING HEIGHT: 33"-36" AFF. • GRAB BARS TO BE 1-1/4"-1-1/2" DIA. W/ GRIPPABLE SURFACE. • TOILET PAPER DISPENSER CENTER MOUNTING HEIGHT: 19" AFF. • LAVATORY RIM OR COUNTER HEIGHT: NO HIGHER THAN 34" AFF • MIRROR HEIGHT: BOTTOM EDGE NO HIGHER THAN 40" AFF. • CONTROLS HEIGHT AND REACH RANGES ARE AS FOLLOWS: • FORWARD APPROACH: 15"-48" AFF; OVER OBJECT 44" AFF MAX, • SIDE APPROACH: 9"-54" AFF; OVER OBJECT 46" AFF MAX. GENERAL RESTROOM NOTES: 1. PROVIDE THE FOLLOWING RESTROOM FIXTURES IN WHITE VITREOUS CHINA FINISH UNLESS OTHERWISE INDICATED OR APPROVED, AS REPRESENTED IN DOCUMENTS. • FLOOR MOUNT TANK TYPE WATER CLOSETS. • WALL HUNG WITH ELONGATED RIM URINALS. • WALL MOUNT WITH OVERFLOW LAVATORY. • HAND OPERATED FLUSH & FAUCET CONTROLS. • INSTA-HOT ELECTRIC HOT WATER HEATER UNDER LAVATORY. • EXHAUST FAN. 1. PROVIDE THE FOLLOWING RESTROOM ACCESSORIES IN BRUSHED CHROME FINISH UNLESS OTHERWISE STATED OR APPROVED. BRUSHED STAINLESS STEEL IS AN ACCEPTABLE ALTERNATIVE FINISH. WATER CLOSET AREA: • (1) SURFACE MOUNT DOUBLE TOILET PAPER DISPENSER PER WATER CLOSET. • (1) SANITARY NAPKIN DISPOSAL PER WOMENS WATER CLOSET. • (1) SANITARY NAPKIN DISPENSER PER WOMENS RESTROOM. • (1) COAT HOOK PER WATER CLOSET/URINAL. • (1) TOILET SEAT PROTECTOR DISPENSER PER RESTROOM. LAVATORY AREA: • (1) AUTOMATIC HIGH VELOCITY HAND AIR DRYER (XLERATOR OR SIM) WITH ADA RECESSED TRAY & WALL GUARD.. • (1) SEMI-RECESSED COMBINATION FOLDED PAPER TOWEL DISPENSER / MEDIUM-SIZED TRASH RECEPTACLE PER RESTROOM. • (1) LIQUID SOAP DISPENSER PER LAVATORY. • (1) 24"W x 36"H MIN. MIRROR WITH METAL TRIM PER LAVATORY. MISC. • (1) FLOOR DRAIN WITH TRIM FLUSH WITH FINISHED FLOOR PER REST ROOM. • (1) BABY CHANGING STATION PER REST ROOM. RESTROOM FIXTURE & EQUIP. NOTES:Rev. #Issue / RevisionDate130% Set12-03-2021SCALE:1/4" = 1'-0"1 RESTROOM ENLARED PLAN SCALE:1/4" = 1'-0"6 UNISEX ENLARGED PLAN SCALE:1/4" = 1'-0"9 KITCHEN ELEVATION SCALE:1/4" = 1'-0"10 KITCHEN ELEVATION SCALE:1/4" = 1'-0"3 WOMEN'S RR SCALE:1/4" = 1'-0"5 WOMEN'S RR SCALE:1/4" = 1'-0"2 MEN'S RR SCALE:1/4" = 1'-0"4 MEN'S RR 2 SCALE:1/4" = 1'-0"7 UNISEX RR1 SCALE:1/4" = 1'-0"8 UNISEX RR 2 N10°44'40"W 30.91'N53°12'20"W 100.06'S84°24'38"W 231.72'Δ=6°05'14"L=53.23'R=501.00'CH=53.20'CHB=S87°27'15"WN89°30'08"W 467.55'S00°10'49"W 719.91'S89°30'08"E 1043.41'N32°20'22"W 140.79'Δ=29°50'18"L=283.82'R=545.00'CH=280.63'CHB=N17°25'13"WN04°50'27"W 93.19'Δ=4°00'52"L=68.70'R=980.50'CH=68.69'CHB=N07°35'30"WΔ=6°51'22"L=35.90'R=300.00'CH=35.88'CHB=N13°01'37"WN16°27'18"W 36.00'Δ=5°42'39"L=29.90'R=300.00'CH=29.89'CHB=N13°35'58"WN09°55'08"W 13.58'NW SUNRISE DRIVENW 6TH STREETCIVIL DESIGN ADVANTAGE2104.247WAUKEE CROSSING ENGINEER:TECH: REVISIONS DATE WAUKEE, IOWA20 FIRST SUBMITTAL 10/12/2021 PHONE: (515) 369-4400 3405 S.E. CROSSROADS DRIVE, SUITE G GRIMES, IOWA 50111 DIMENSION PLAN OVERALL GENERAL NOTESPAVEMENT THICKNESS3 Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.NEW CONSTRUCTION PLANS FOR SAA C:\Users\spoole\Documents\21113 Converge NW, Waukee, IA_3&4-Plex One-Story Townhouse_spoolePMDSN.rvt12/2/2021 3:26:30 PMCONVERGE NWTOWNHOUSESWAUKEE, IOWA21113 G-000 CONVERGE NW TOWNHOUSES WAUKEE, IOWA COVER SHEET SP 1. THESE DOCUMENTS & THE DESIGN THEY REPRESENT ARE THE PROPERTY OF SIMONSON & ASSOCIATES ARCHITECTS LLC. NO CHANGES TO THESE DOCUMENTS EITHER IN WHOLE OR IN PART MAY BE MADE IN ANY WAY WITHOUT THEIR PRIOR KNOWLEDGE & WRITTEN CONSENT. 2. REFER TO ADDITIONAL NOTES AND LEGENDS ON ALL OTHER DOCUMENTS. 3. REFER TO CIVIL, GEOTECHNICAL, ENVIRONMENTAL, STRUCTURAL, FIRE SUPPRESSION, PLUMBING, MECHANICAL, ELECTRICAL, COMMUNICATIONS, ELECTRONIC SAFETY & SECURITY DOCUMENTS FOR ADDITIONAL INFORMATION OR REQUIREMENTS. REFERENCE TO OTHER DISCIPLINES IS CONCEPTUAL FOR PURPOSES OF COORDINATION WITH ARCHITECTURAL DESIGN ONLY. 4. BEFORE COMMENCEMENT OF ANY WORK, CONTRACTOR SHALL GIVE ALL NOTICES AND OBTAIN ALL PERMITS. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES, LAWS, ORDINANCES, RULES, REGULATIONS, REQUIREMENTS OF GOVERNING AGENCIES AND AUTHORITIES,HAZARDOUS MATERIAL APPLICATION AND DISPOSAL REQUIREMENTS, ETC. 5. THE ADA OR ADAAG IS A CIVIL RIGHTS ACT AND IS SUBJECT TO LEGAL INTERPRETATION THROUGH THE JUDICIAL PROCESS. REASONABLE CARE WAS EXERCISED IN INTERPRETING THE GUIDELINES AND ALL GUIDELINES MAY NOT BE INDICATED ON THESE PLANS: HOWEVER, FAILURE TO IDENTIFY A GUIDELINE DOES NOT GIVE THIS CONTRACTOR THE RIGHT TO VIOLATE THEM. THE CONTRACTOR MUST COMPLY WITH ALL GUIDELINES AS REQUIRED BY THE ADAAG. 6. THESE DRAWINGS REPRESENT THE COMPLETED PROJECT, AT TIME OF SUBSTANTIAL COMPLETION. THE INTENT OF THE DRAWINGS IS TO INCLUDE ALL ITEMS NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. UNLESS OTHERWISE NOTED, THEY DO NOT REPRESENT THE MEANS AND METHODS OF CONSTRUCTION. SEQUENCING AND MEANS AND METHODS OF CONSTRUCTION SHALL BE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 7. THESE DRAWINGS DO NOT CONTAIN INFORMATION WITH REGARD TO CONSTRUCTION SAFETY PROCEDURES. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL CONSTRUCTION SAFETY AND SHALL PERFORM ALL WORK IN ACCORDANCE WITH GOVERNING AUTHORITIES CONSTRUCTION SAFETY GUIDELINES. 8. PROVIDE COMPLETE IN PLACE ALL LABOR, TRANSPORTATION, MATERIAL, TAXES, FEES, PERMITS, LICENSES, INSURANCE, UTILITIES, INSPECTIONS, EQUIPMENT, MACHINERY, SUPERVISION, AND OTHER ITEMS NECESSARY TO COMPLETE THE WORK IN STRICT COMPLIANCE WITH THE PLANS, DOCUMENTS AND SPECIFICATIONS PREPARED BY THE ARCHITECT AND APPROVED BY THE OWNER. 9. VERIFY EXISTING CONDITIONS PRIOR TO FABRICATION AND PRIOR TO PROCEEDING WITH THE WORK, AND NOTIFY THE ARCHITECT IMMEDIATELY OF SIGNIFICANT DISCREPANCIES WHICH MAY IMPACT AESTHETICS, DURABILITY, COST AND/OR SCHEDULES. 10. DO NOT SCALE DRAWINGS IN ORDER TO DETERMINE INTENDED LAYOUT OR DIMENSIONS. IF DIMENSIONS ARE IN QUESTION THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION BEFORE CONTINUING WITH WORK. DRAWINGS ARE INTENDED ONLY AS A GRAPHICALLY CORRECT REPRESENTATION OF WORK TO BE ACCOMPLISHED. 11. THE CONTRACTOR SHALL PROTECT ALL EXISTING ENTITIES. REMOVE, REPLACE OR REPAIR MATERIALS, FACILITIES AND SERVICES DAMAGED DURING THE COURSE OF CONSTRUCTION TO THE SATISFACTION OF THE OWNER AND GOVERNING AUTHORITY. 12. ALL WORK SHALL BE OF GOOD QUALITY AND ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND FREE FROM DEFECTS FOR A PERIOD OF 1 YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION OF WORK. ANY EXTENDED WARRANTIES OBTAINED FROM SUPPLIERS OR SUBCONTRACTORS SHALL BE FORWARDED TO THE OWNER. 13. ALL REQUIREMENTS NOT FOLLOWED, INCLUDING SUBSTITUTIONS NOT PROPERLY APPROVED AND AUTHORIZED, IN WRITING, MAY BE CONSIDERED DEFECTIVE. 14. FAILURE TO IDENTIFY A STANDARD, RECOMMENDATION &/OR REQUIREMENT DOES NOT GIVE ANYONE THE RIGHT TO VIOLATE ANY CODE & GOVERNING AUTHORITY REQUIREMENTS, MINIMUM QUALITY OR QUANTITY REQUIRED, ASTM & OTHER INDUSTRY STANDARDS, MANUFACTURER RECOMMENDATIONS & REQUIREMENTS, ETC. 15. COMPLY WITH ALL WEATHER-RELATED CONSTRUCTION REQUIREMENTS. DO NOT BUILD WITH OR ON FROZEN, SATURATED, CONTAMINATED OR INAPPROPRIATE SUBSTRATES OR CONDITIONS. BUILD OVER DRY COMPACTED APPROVED GRADE WITH APPROVED APPROPRIATE MATERIALS. 16. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM AND OFF ALL BUILDINGS WITHOUT PONDING OR WATER ADJACENT TO OR ON BUILDINGS OR PAVEMENTS. 17. BY SUBMITTING SHOP DRAWINGS, PRODUCT DATA AND SAMPLES, THE GENERAL CONTRACTOR AND SUB- CONTRACTOR HAS VERIFIED AND APPROVED THE INFORMATION CONTAINED WITHIN. THE GENERAL CONTRACTOR'S REVIEW AND APPROVAL SHALL BE SHOWN ON EACH SUBMITTAL PRIOR TO THE SUBMISSION TO THE ARCHITECT. 18. THE GENERAL CONTRACTOR SHALL FORWARD TO SUBCONTRACTORS & SUPPLIERS, FULL SETS OF BIDDING &/OR CONSTRUCTION DOCUMENTS, INCLUDING, BUT NOT LIMITED TO, DRAWINGS, SPECIFICATIONS, ADDENDA, CLARIFICATIONS, BID FORMS, & ALL OTHER DOCUMENTATION ISSUED BY ARCHITECT & ARCHITECT'S CONSULTANTS TOWARD CONVEYING A COMPLETE & TIMELY PROJECT. GENERAL NOTES Simonson & Associates Architects LLC and their consultants has completed these design documents to the level of detail requested by our client. The level of detail may range from schematic design document(s) mainly conveying programmatic information to fully detailed documents and specifications. However, the clients intent and expectations are that these documents be used as the basis for design for an complete all-inclusive project based upon industry standards & manufacturer recommendations for all disciplines & materials. It should also satisfy all authorities having jurisdiction requirements. IMPORTANT DESIGN SCOPE NOTE: 24"x36" SHEET (FULL SIZE) - SCALE IS AS NOTED. 12"x18" SHEET (HALF SIZE) - SCALE IS ONE-HALF OF WHAT IS NOTED OTHER SHEET SIZES NOT TO SCALE SCALE NOTE: - DOOR INDICATOR - FINISH INDICATOR - KEYNOTE - REVISION INDICATOR - ROOM INDICATOR - WALL / FLOOR / CEILING / ROOF ASSEMBLY TYPE IDENTIFIER - WINDOW INDICATOR LEGEND: - - - - - NOTE: THIS DRAWING DOES NOT REPRESENT AN AS-BUILT CONDITION. ACTUAL DETAILS AND DIMENSIONS MAY VARY AND ARE SUBJECT TO CHANGE. AS-BUILT CONDITIONS MUST BE FIELD VERIFIED PRIOR TO FINAL LAYOUT AND CONSTRUCTION OF INTERIOR TENANT IMPROVEMENTS. NOTE: ALL DESIGN DOCUMENTS ARE SUBJECT TO AUTHORITIES HAVING JURISDICTION REVIEW AND APPROVAL. - - ARCHITECTURAL A-101 3/4-PLEX 1-STORY FLOOR PLAN A-102 5-PLEX 1-STORY FLOOR PLAN A-103 4-PLEX 2-STORY FLOOR PLANS A-111 3/4-PLEX 1-STORY ROOF PLAN A-112 5-PLEX 1-STORY ROOF PLAN A-113 4-PLEX 2-STORY ROOF PLAN A-201 3/4-PLEX 1-STORY EXT. ELEVATIONS A-202 5-PLEX 1-STORY EXTERIOR ELEVATIONS A-203 4-PLEX 2-STORY EXTERIOR ELEVATIONS A-411 TYPE 2A UNIT PLAN A-412 UNIT 2B+D UNIT PLAN A-413 TYPE 3A UNIT PLAN A-414 TYPE 3B UNIT PLAN A-415 TYPE 3C UNIT PLAN DOCUMENTS BY OTHERS ELECTRONIC SAFETY & SECURITY (Refer to these design documents under separate cover.) CIVIL -LANDSCAPING (Refer to these design documents under separate cover.) GEOTECHNICAL INVESTIGATIONS (Refer to these condition documents under separate cover) PLUMBING (Refer to these design documents under separate cover.) SPECIFICATION MANUAL Not Provided - All Specification Notes included on drawings. INDEX OF DRAWINGS STRUCTURAL S-001 STRUCTURAL NOTES S-101 FOUNDATION PLAN - 2 STORY 8 PLEX S-102 FOUNDATION PLAN - 2 STORY 6 PLEX S-103 FOUNDATION PLAN - 1 STORY 8 PLEX S-201 FOUNDATION DETAILS S-301 FRAMING PLAN - 2 STORY 8 PLEX S-302 FRAMING PLAN - 2 STORY 6 PLEX S-401 ROOF FRAMING PLAN - 2 STORY 8 PLEX S-402 ROOF FRAMING PLAN - 2 STORY 6 PLEX S-403 ROOF FRAMING PLAN - 1 STORY 8 PLEX S-501 FRAMING DETAILS ENERGY Refer to Prescriptive Method on G-101 COMMUNICATIONS (Refer to these design documents under separate cover.) HEATING, VENTILATING, & AIR CONDITIONING (Refer to these design documents under separate cover.) ELECTRICAL (Refer to these design documents under separate cover.) CLIENT ARCHITECT CIVIL ENGINEER STRUCTURAL ENGINEER GENERAL CONTRACTOR I hereby certify that the portion of this technical submission described below was prepared by me or under my direct supervision and responsible charge. I am a duly licensed architect under the laws of the State of Iowa. Registration Expires Pages or Sheets covered by this seal: Signature O L NAEROF NSCEEWOI AIDLP TCECTIHA RSS I IA Reg. # Date ARCHITECT AS LISTED IN INDEX June 30, 2023 Michael W. Simonson 2704 Michael W. Simonson 2704 JURISDICTION GENERAL G-000 COVER SHEET G-001 SPECIFICATION NOTES G-011 ACCESSIBILITY REQUIREMENTS & GUIDELINES G-101 3/4-PLEX 1-STORY CODE REVIEW G-102 5-PLEX 1-STORY CODE REVIEW G-103 4-PLEX 2-STORY CODE REVIEW KEY PLAN XX-XX-2022 Simonson & Associates Architects L.L.C. 1717 Ingersoll Avenue, Suite 117 Des Moines, IA 50309 (515) 440-5626 (515) 440-0964 Fax contact: Stephanie Poole e-mail: spoole@simonsonassoc.com Civil Design Advantage 3405 SE Crossroads Dr., Suite G Grimes, IA 50111 (515) 369-4400 (515) 369-4410 Fax contact: Ryan Hardisty e-mail: RyanH@cda-eng.com Raker Rhodes Engineering, LLC 4717 Grand Ave. Des Moines, IA 50312 (515) 277-0275 (515) 277-0276 Fax contact: John Rhodes e-mail: jrhodes@rakerrhodes.com contact: Chris Harre e-mail: charre@rakerrhodes.com Hubbell Construction Services 6900 Westown Parkway West Des Moines, IA 50266 (515) 243-3228 (515) 280-2000 Fax Fax contact: Colleen Ladd e-mail: colleen.ladd@hubbellrealty.com phone: (515) 221-6201 contact: (407) 489-3626 (mobile) Hubbell Realty Company - Managing Member 6900 Westown Parkway West Des Moines, Ia 50266 (515) 280-2041 (515) 280-2000 Fax contact: Matthew Weller e-mail: matt.weller@hubbellrealty.com phone: (515) 868-6874 City of Waukee Development Services 230 W. Hickman Road Waukee, IA 50263 515) 987-4522 contact: Keith Rash e-mail: krash@waukee.org phone: (515) 978-9533 cell Rev. #Issue / RevisionDate330% Set12-03-2021 Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.SAA C:\Users\spoole\Documents\21113 Converge NW, Waukee, IA_3&4-Plex One-Story Townhouse_spoolePMDSN.rvt12/2/2021 3:26:31 PMCONVERGE NWTOWNHOUSESWAUKEE, IOWA21113 G-001 SPECIFICATION NOTES SP DIVISION 01 – GENERAL REQUIREMENTS GENERAL: 1. Refer to additional notes and requirements on all other documents and other disciplines documents. 2. In the event that a discrepancy is found between any codes, governing authority, drawings, documents, or any other requirements, the most restrictive or stringent requirement shall be used. 3. Cooperate fully with separate contractors so work on those contracts may be carried out smoothly, without interfering with or delaying work under separate Contracts. 4. Owner reserves the right to place and install equipment in all areas of building and site, before Substantial Completion, provided it does not interfere with completion of the Work. CONSTRUCTION SCHEDULE - Before commencing Work, submit a schedule showing the sequence, commencement and completion dates for all phases of the Work. Coordinate the Work of this Contract with work performed under separate contracts. TEMPORARY CONSTRUCTION - Provide all required temporary construction, temporary facilities and temporary utilities required to complete the project including but not limited to, erosion control structures, material storage areas, enclosures for tools and other equipment, a field office, temporary utility services for construction usage, temporary heat and cover, and temporary toilet facilities. CLEAN-UP - The Contractor shall be responsible for construction trash removal services and shall at all times keep the building and site free from accumulation of debris. Upon completion, the building, including glazing, and site shall be cleaned and turned over to the Owner. WARRANTY - All work shall be of good quality and all materials and equipment shall be new and free from defects for a period of one year from the date of substantial completion of work. Any extended warranties obtained from suppliers of subcontractors shall be forwarded to the owner. INSURANCE - The Contractor shall maintain Workers' Compensation Insurance and Comprehensive Public Liability and Builders Risk Insurance. QUALITY ASSURANCE - The Contractor shall implement a Quality Assurance program which includes independent agency testing and observation of soils, cast-in-place concrete and structural steel, as well as inspection of work in progress. The owner will have the right to perform inspections and/or independent tests at any time. All lines and levels shall be established by a Registered Land Surveyor. RECORD DOCUMENTS - Upon completion of the project, the Contractor shall prepare a complete set of record documents including a list of Suppliers and Subcontractors used on the project, manufacturer's warranties, operation and maintenance manuals for major pieces of equipment and instruction manuals when appropriate for building systems. SUBMITTALS 1. Allow enough time for submittal review, including time for resubmittals, No extension of the Contract Time will be authorized because of failure to transmit submittals enough in advance of the Work to permit processing, including resubmittals. 2. By submitting shop drawings, product data and samples, the contractor has verified and approved the information contained within. The contractor's review and approval shall be shown on each submittal prior to the submission to the architect. 3. Provide samples for each type and color for review of kind, color, pattern, and texture for a check of these characteristics with other elements. 4. Immediately on discovery of the need for interpretation of the Contract Documents, and if not possible to request interpretation at Project meeting, prepare and submit an RFI. 5. Include as part of each alternate, miscellaneous devices, accessory objects, and similar items incidental to or required for a complete installation whether or not indicated as part of alternate. Modify or adjust affected adjacent work as necessary to completely integrate work of the alternate into Project. QUALIFICATIONS 1. Installer Qualifications: A firm or individual experienced in installing, erecting, or assembling work similar in material, design, and extent to that indicated for this Project, whose work has resulted in construction with a record of successful in-service performance. 2. Manufacturer Qualifications: A firm experienced in manufacturing products or systems similar to those indicated for this Project and with a record of successful in-service performance, as well as sufficient production capacity to produce required units. 3. Fabricator Qualifications: A firm experienced in producing products similar to those indicated for this Project and with a record of successful in-service performance, as well as sufficient production capacity to produce required units. 4. Professional Engineer Qualifications: A professional engineer who is legally qualified to practice in jurisdiction where Project is located and who is experienced in providing engineering services of the kind indicated. Engineering services are defined as those performed for installations of the system, assembly, or product that are similar to those indicated for this Project in material, design, and extent. 5. Specialists: Certain items require that specific construction activities shall be performed by entities who are recognized experts in those operations. Specialists shall satisfy qualification requirements and shall be engaged for the activities indicated. 6. Testing Agency Qualifications: An independent agency with the experience and capability to conduct testing and inspecting indicated and where required by authorities having jurisdiction, that is acceptable to authorities. 7. Factory-Authorized Service Representative Qualifications: An authorized representative of manufacturer who is trained and approved by manufacturer to inspect installation of manufacturer's products that are similar in material, design, and extent to those indicated for this Project. 8. Manufacturer's Warranty: Preprinted written warranty published by individual manufacturer for a particular product and specifically endorsed by manufacturer to Owner. The Specification Notes are organized into Divisions using the CSI/CSC's "MasterFormat" numbering system. The following is not intended to be an all inclusive list, but rather a general summary. Failure to identify a requirement does not give any contractor, general contractor or its sub-contractors the right to violate any codes, governing authority, minimum quality or quantity, industry standards, manufacturer recommendations, etc. DIVISION 02 - EXISTING CONDITIONS GENERAL: 1. Verify existing conditions before fabrication or prior to proceeding with the work, and notify the architect immediately of significant discrepancies. 2. Maintain existing building in a weathertight condition throughout construction period. Repair damage caused by construction operations. Protect building and its occupants during construction period. DIVISION 03 – CONCRETE Refer to Structural Documents) GENERAL: 1. All concrete shall be reinforced unless otherwise noted. 2. All concrete shall be saw cut. If saw cuts are not specified, contact architect and engineer. If possible provide saw cut under demising walls. 3. Concrete to only be placed over dry sub-grade to prevent heaving in winter. 4. Forms where concrete is to be exposed shall be smooth and free of defects. 5. Exterior paving to be 1/4" lower than interior finish floor, sloping away from building. Where no paving, top of finished grade a minimum of 4" below finish floor. 033500 CONCRETE FINISHING 1. Concrete floor slab shall be installed to a true plane with no deviations greater than 1/4" in any 10'-0" direction and free from blemishes and trowel marks. 2. Trowel Finish: Apply a trowel finish to monolithic slab surfaces exposed to view and slab surfaces to be covered with resilient flooring, carpet, ceramic or quarry tile, paint, or another thin film-finish coating system. Grind smooth any surface defects that would telegraph through applied floor covering system. 3. Nonslip Finish: Apply a nonslip finish, perpendicular to main traffic route, to all exterior concrete platforms, steps, and ramps. 4. Slope requirements for exterior concrete sidewalks of 5% maximum running slope, 2% maximum cross slope, or 8.3% maximum slope for ramps. DIVISION 04 – MASONRY (Refer also to Structural Documents) GENERAL: 1. Large masonry joint or cut masonry unit to maintain masonry coursing joint at finish floor line. 040100 MAINTENANCE OF MASONRY - If acid wash is used be sure to take appropriate protection measures to eliminate any damage from getting it on other unlike materials. 040513 MASONRY MORTARING - Use mortar made with integral water repellent admixture that does not reduce flexural bond strength where masonry with integral water repellent admixture is required. 040516 MASONRY GROUTING - 1. Use grout made with integral water repellent admixture that does not reduce flexural bond strength where masonry with integral water repellent admixture is required. 2. All voided spaces below grade shall be grouted full. 040519 MASONRY ANCHORAGE AND REINFORCING - Space masonry anchors not more than 16" o.c. vertically and 24" o.c. horizontally with not less than 1 anchor for each 2.67 sq. ft. of wall area. Install additional anchors within 12" of openings and at intervals, not exceeding 36 inches, around perimeter. 040523 MASONRY ACCESSORIES - Joints, Flashing & Drainage 1. Install vertical expansion joint minimal at column/grid lines and at the head of door jambs/openings or as otherwise noted or where required per standard material practice to reduce stress cracking. No control joint/expansion joint at main structural bearing, keep away 2'-6" min. 2. No drip edge required if membrane flashing is used, but it should extend out and be trimmed back to face of adjacent masonry. Drip edge required if metal flashing is used. 3. Through wall flashing at base of wall a minimum of 4" above finish grade back and up behind vapor barrier, weeps at 24" o.c. above flashing, horizontal & vertical joints overlapped & sealed. 4. Through wall flashing above lintels back and up behind vapor barrier, weeps at 24" o.c. above flashing. End dams at openings, horizontal and vertical joints overlapped and sealed. 5. All masonry to have 1" minimum air space away from adjacent material. All cavity wall air spaces are to be maintained free of mortar. Strike flush all joints on cavity side of CMU and brick masonry. Provide mortar net at base of wall, above all lintels and above all intermediate thru-wall flashing. 042100 CLAY UNIT MASONRY (Brick) 1. For ends of sills and caps and for similar applications that would otherwise expose unfinished brick surfaces, provide units without cores or frogs and with exposed surfaces finished. 2. Provide brick that has been tested is rated "not effloresced." 047210 CAST STONE MASONRY - Provide units made with integral water repellent admixture that does not reduce flexural bond strength. DIVISION 05 – METALS (Refer also to Structural Documents) GENERAL: 1. All steel exposed on the exterior or to moisture to be galvanized. 2. All metal coping to be pre-finished. 3. All exposed steel lintels to be painted to match surrounding materials. 4. All architectural steel and metal fabrications to be continuous welds, grinded smooth and sanded for a neat and smooth final finish. DIVISION 06 – WOOD, PLASTICS, AND COMPOSITES (Refer also to Structural documents) GENERAL: 1. All wood framing members, including wood sheathing, that rest on the exterior foundation walls & are less than 8” from exposed earth & all wood in direct contact with masonry, concrete, earth or material that retains moisture shall be of naturally durable or preservative-treated wood. 2. The ends of wood girders entering exterior masonry or concrete walls shall be provided with a 1/2” air space on top, sides and end, unless naturally durable or preservative-treated wood. 3. All wood that is part of a roof/parapet or flashing assembly and are fully wrapped by membrane or break metal and protected from moisture need not be treated. 4. Wood blocking is required for, but not limited to millwork, cabinets, handrails, rest room fixtures & accessories, grab bars, future grab bars as required in R / Multi-family occupancies, door & window frames, overhead door bucks, hardware, owner/tenant fixtures & equipment, etc.. 5. Exterior sheathing should be plywood at all potential signage locations. Fire retardant / rated where required. DIVISION 07 – THERMAL AND MOISTURE PROTECTION GENERAL: 1. Design and installation of roof drainage systems shall comply with the IPC. 2. Insulate and seal to ensure adequate air infiltration barrier around all exterior penetrations to prevent water and sprinkler pipe freezing. 3. Provide 2" thick continuous perimeter rigid insulation min. 24" horizontally from interior face of grade beam into building and vertically to bottom of the grade beam along the interior face. 4. Roof assembly to meet UL Class "A" fire rating. 072100 THERMAL INSULATION 1. Refer to requirements of each designated tested assembly where insulation is to be installed (wall, floor-ceiling, or roof-ceiling). Insulation shall comply with the specific requirements as listed in the designated tested assembly. Any descrepencies between the general descriptions noted in the plans and the designated tested assembly noted shall be brought to the attention of the architect immediately before any work is performed. 2. Exterior wall insulation shall be min R21 Fiber Glass Building Insulation Batts, or approved equal. 3. Below grade perimeter insulation shall be rigid extruded polystyrene board with min. R10. 4. Sound attenuating fiberglass batt insulation (SAFB) in interior walls shall be per the thickness indicated on the drawings. SAFB shall be unfaced fiberglass batts. 072200 ROOF AND DECK INSULATION - R-38 blown-in insulation for attic space in pitched roofs, unless otherwise noted. 072500 WEATHER BARRIER 1. Weather barrier is a weather-resistant membrane for vertical building envelope protection that will maintain air/moisture resistance and will maintain moisture-vapor permeability. 2. Joints & seems shall be sealed, including at transitions in changes of materials. 3. Provide seam tape, sealants, adhesives, flashing and other accessories recommended by the manufacturer for a complete weather barrier system. Install materials in strict accordance to the manufacturer's instructions. 4. Weather barrier shall be DuPont Tyvek CommercialWrap or approved equal. 5. Joints shall be "shingled" to shed water, with the lower level bands installed first and with a minimum of 6" overlap. 6. Seal seam of the weather barrier with seam tape at all vertical and horizontal overlapping seams. Seal any tears and cuts per manufacturer's instructions. 7. The weather barrier manufacturer's flashing system shall be installed around all windows and doors in accordance with the manufacturer's instructions. 8. Penetration shall be sealed in accordance with IECC Section C402.4.2. The joints and seals shall be securely installed in or on the joint for its entire length. 073113 ASPHALT SHINGLE ROOFING SYSTEM 1. Roofing should be installed in strict accordance with manufacturer’s instructions and weather limitations to obtain full roofing warranties. 2. Provide at a minimum manufacturer's 25-year warranty, which begins after the date of substantial completion, and covers the roofing membrane, associated flashing, roof insulation, roof accessories and labor. 3. Roofing shall be CertainTeed brand, architectural shake-style, minimum 25-year warranty asphalt shingles, Landmark Premium Series, color is Moire Black, or approved equal. 4. Provide ice and water protection underlayment membrane installed in valleys and at eaves, and around all penetrations for a secure flashing interface with the roofing system. Ice and water protection underlayment material shall extend from the edge of the eave to a minimum of 2 feet inside of the interior face of the exterior wall, and shall extend a minimum of 2 feet of either side of a valley. 5. Ice and water protection underlayment membrane shall be CertainTeed “WinterGuard” Waterproofing Shingle Underlayment, or approved equal. Install per instructions of shingle and waterproofing membrane manufacturers. 6. Roof Slopes between 2:12 and 4:12; Apply two layers of roofing felt underlayment over areas not protected by ice and water protection underlayment membrane at eaves, with end and edges weather- lapped 19 inches. Stagger end laps each consecutive layer. 7. Roofing felt underlayment shall be CertainTeed “Roofers’ Select”, ASTM D 6757 or approved equal. Install per instructions of shingle and underlayment manufacturers. 8. Install flashing, drip edge, sealants, and accessories in conformance with roofing manufacturer’s instructions. 078413 THROUGH-PENETRATION FIRESTOPPING 1. Provide products that upon curing do not re-emulsify, dissolve, leach, breakdown, or otherwise deteriorate over time from exposure to atmospheric moisture, sweating pipes, ponding water or other forms of moisture characteristic during and after construction. 2. When intumescent products are used, provide products that do not contain sodium silicate or any other water soluble intumescent ingredient in the formulation. 3. Provide firestop products that do not contain ethylene glycol. 4. Provide firestop sealants sufficiently flexible to accommodate motion such as pipe vibration, water hammer, thermal expansion and other normal building movement without damage to the seal. 5. Pipe insulation shall not be removed, cut away or otherwise interrupted through wall or floor openings. Provide products appropriately tested for the thickness and type of insulation utilized. 6. Fire rated pathway devices shall be the preferred product and shall be installed in all locations where frequent cable moves, add-ons and changes will occur. Such devices shall be: A. Capable of retrofit around existing cables B. Designed such that two or more devices can be ganged together C. Maintenance free such that no action is required to activate the smoke and fire sealing mechanism 7. When mechanical cable pathways are not practical, openings within walls and floors designed to accommodate voice, data and video cabling shall be provided with re-enterable products specifically designed for retrofit. 8. Provide through-penetration firestop systems and fire-resistive joint systems subjected to an air leakage test conducted in accordance with the Standards, ANSI/ UL1479 for penetration firestop systems, with published L-Ratings for ambient and elevated temperatures as evidence of the ability of the fire-resistive joint system to restrict the movement of smoke. 9. Provide T-Rating Collar Devices tested in accordance with ASTM E814 or ANSI/UL1479 for metallic pipe penetrations requiring T- Ratings per the applicable building code. 10. Provide a fire-rated grommet for all individual or small grouped cable applications up to 0.53 in. (14 mm). 11. Provide moisture-curing products where inclement weather or greater than transient water exposure is expected. 12. Product manufacturer shall be Hilti, Inc. or approved equal. 078443 JOINT FIRESTOPPING 1. Provide firestopping joint protection at all rated assemblies, including all pre-cast wall joints. 2. Provide firestopping composed of components that are compatible with each other and substrates forming joints under conditions of service and application, as demonstrated by the firestopping manufacturer based on testing and field experience. 3. Provide components for each fire-resistive joint system that are needed to install fill material. Use only components specified by the firestopping manufacturer and approved by the qualified testing agency for the designated fire-resistance-rated systems. 4. Product manufacturer shall be Hilti, Inc. or approved equal. DIVISION 08 – OPENINGS GENERAL: 1. All exterior window framing to be thermally broken. 2. Sill pan by window manufacturer set in mastic over break metal sill flashing, with drip edge, set in mastic at bottom of all window framing. End dams at openings. Horizontal and vertical joints overlapped and sealed. 3. Sealant and backer rod at window perimeter. Verify system weeps are cleared, free of sealant and debris. 4. Additional framing, structural supports and/or bracing shall be identified by the glazing sub-contractor prior to bidding, fabrication and installation. 5. All glass in interior doors, frames, sidelights, windows and storefront to be 1/4", tempered, laminated and/or rated glass where required. 6. All glass in exterior doors, frames, sidelights, windows and storefront to be insulated, tempered, laminated and/or rated glass where required. 7. All interior glass between tempered and non-tempered spaces shall be clear insulated. 081000 DOORS & FRAMES - (Refer to Door & Frame Schedule & Elevations) Thresholds, if provided at a doorway, must not exceed 3/4 inch in height for exterior sliding doors or 1/2 inch for other types of doors. Changes in level up to 1/4 inch can be vertical and do not need an edge treatment. Changes in level between 1/4 inch and 1/2 inch must have a beveled slope equaling 1:2. 1. Unit entry doors shall be as required by the Owner. Provide and install the following: A. Door viewer peephole with 180 degree view. B. Hardware finish to be determined by architect. 2. Unit interior doors shall be hollow core molded door as manufactured by Lynden Door Co., or approved equal, factory finished molded hardboard door. Doors are to be interior pre-hung doors. A. Hollow core molded doors, 1 3/8" thick, two panel door with factory finish. B. Factory prepared for hardware. a. 3 1/2 x 3 1/2 RC1841 hinge 2CD. Single bore 2 3/4" Mortise Radius Corner. b. Passage or privacy lever as required. c. Wood core jambs shall be prefinished. d. Casing shall be prefinished, manufactured by Moulding and Millwork, or an approved equal. Profile, style, finish specification by others. 3. Interior doors at corridors, except at unit entry, shall be factory finished fire-rated hollow metal doors with hollow metal frames with smooth finish, U.N.O. 4. Patio sliding glass doors shall be Builders Series Vinyl Sliding Patio Door with fiberglass screen, Low-E glass as manufactured by Ply Gem or approved equal. Color to be white. 5. Insulated overhead doors, verify garage door opener and controls with owner. 083000 ACCESS DOORS & PANELS - 2018 IBC-1209.2 Access to ATTIC SPACES. An opening not less than 20" by 30" shall be provided to any attic area having a clear height of over 30". 1. Attic access doors shall be rated for roof/ceiling assemblies and tested in accordance with ASTM E 119 or UL 263 as horizontal assemblies and labeled by an approved agency for such purpose. 2. Attic access doors shall be insulated to comply with energy code requirements for roof insulation. 085000 WINDOWS - (Refer to Window Schedule & Elevations) 1. Windows shall be vinyl PlyGem Builders Series, or approved equal. 2. Operable Parts in Dwelling Units & Sleeping Units – operating hardware for operable windows, etc. shall be placed within one or more of the ANSI accessible reach ranges, shall be operable with one hand & shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be 5.0 pounds maximum. 08 70 00 HARDWARE - Door hardware shall have a shape that is easy to grasp with one hand and does not require light grasping, pinching, or twisting of the wrist to operate. (ICC A117.1 2009 Sec. 309) Lever handles, no round knobs. (ICC A117.1 2009 Sec. 1003.9) 088300 MIRRORS Mirrors above accessible lavatories shall have the bottom edge of the reflecting surface 40” maximum above the floor. DIVISION 10 – SPECIALTIES Window coverings, toilet accessories, lockers, and flagpole shall be provided. 10 14 00 SIGNAGE: Provide all that apply. All signage shall comply with the ICC A117.1 requirements, where required, such as visual characters, raised characters, international symbols of accessibility, & braille. 1. BUILDING ADDRESS IDENTIFICATION: Approved address numbers or letters, where each character shall be not less than 4” in height and not less than 0.5” in width stroke, shall be installed on a contrasting background and be plainly visible from the street or road fronting the property (& monument sign). When required by the governing authority, address numbers shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or approved sign or means shall be used to identify the structure. Address numbers shall be maintained. 2. UNIT SIGNAGE: A. Unit designation required at exterior of each unit entry. (Confirm also to owner preference) B. Unit directional signage at all building corridor entry points. 3. MARKETING SIGNAGE: Provide official building name & logo signage on building as approved by owner. SPECIFICATION NOTES cont. SPECIFICATION NOTES cont. SPECIFICATION NOTES cont. SPECIFICATION NOTES cont. SPECIFICATION NOTES cont. DIVISION 11 – EQUIPMENT GENERAL: 11 31 13 KITCHEN APPLIANCES – Operable Parts in Dwelling Units & Sleeping Units – Lighting controls, electrical panelboards, electrical switches & receptacle outlets, environmental controls, etc. shall be placed within one or more of the ANSI accessible reach ranges, shall be operable with one hand & shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be 5.0 pounds maximum. (ICC A117.1 2009 Sec. 309) Exceptions include: reset button and shut-offs serving appliances, piping & plumbing fixtures;. (ICC A117.1 2009 Sec. 1003.9) appliance doors and door latching devises shall not be required to comply with the one hand, tight grasping, pinching, twisting or force requirements; bottom hinged appliance doors, when in the open position, shall not be required to comply with reach ranges. (ICC A117.1 2009 Sec. 1003.12.5.1) The location of cooktop controls shall not require reaching across burners. (ICC A117.1 2009 Sec. 1003.12.5.4.4) Ovens shall have controls on front panel, on either side of the door & shall not require reaching across burners. Side-hinged door ovens shall have a countertop positioned adjacent to the latch side of the oven door, bottom-hinged door ovens shall have a countertop positioned adjacent to one side of the door. (ICC A117.1 2009 Sec. 1003.12.5.5) Combination refrigerators & freezers shall have at least 50% of the freezer compartment shelves, including the bottom of the freezer 54” maximum above the floor when the shelves are installed at the maximum heights possible in the compartment. (ICC A117.1 2009 Sec. 1003.12.5.6) 11 31 23 LAUNDRY APPLIANCES – Operable Parts in Dwelling Units & Sleeping Units -Washing Machines & Clothes Dryers, including doors, lint screens, detergent and bleach compartments, etc. (ICC A117.1 2009 Sec. 611.3) shall be placed within one or more of the ANSI accessible reach ranges, shall be operable with one hand & shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be 5.0 pounds maximum. (ICC A117.1 2009 Sec. 309) 11452 APPLIANCES AND EQUIPMENT 1. Provide and install washers, dryers, dishwashers, garbage disposal, range, refrigerator and microwave ovens in each apartment unit. 2. Laundry - GE appliances or approved equal. A. Each apartment shall have an individual side by side unit (as shown on the drawings) within the unit. DIVISION 13 - 21 (Not Used) 079000 JOINT PROTECTION 1. Provide joint sealant at all wall and floor control and expansion joints and exterior doors, windows and other openings. 2. Provide backer rods where required for proper sealant application. Backer rods to be polyethylene closed-cell with a surface skin. 3. Utilize acoustical sealant at all floor/wall/deck junctures prior to installation of base where sound batt is also required. 4. Sealants to be compatible to materials for maximum bonding and longevity. 5. Soft caulk joint between vertical joints of dis-similar materials. Soft caulk joint & metal pan underneath horizontal joints of dis-similar materials. 6. Sealants should be color matched to adjacent materials. DIVISION 09 – FINISHES GENERAL: Transition strips or finish thresholds, if provided, must not exceed 1/2 inch. Changes in level up to 1/4 inch can be vertical and do not need an edge treatment. Changes in level between 1/4 inch and 1/2 inch must have a beveled slope equaling 1:2. 092116 GYPSUM BOARD ASSEMBLIES Refer to assembly types on sheet A-101 for designated vertical assemblies and sheet A-311 for horizontal assemblies. Assembly descriptions are general and for coordination purposes only; the designated UL assembly shall be followed exactly as required. Some UL assemblies require proprietary products. Refer to specific UL assembly listing for acceptable brands and product types. All products required for each designated assembly shall be followed. 1. Provide moisture resistant gypsum board at all wet wall locations including behind water closets, sinks and tub showers. 2. All gypsum board at walls and ceiling to be smooth, properly taped and sanded, ready for painting. 3. Gypsum board expansion control joints shall be used where required per standard gypsum board practice to prevent cracking of drywall as recommended by The Gypsum Construction Handbook, 6th Edition. Joints shall not exceed 30 feet apart for walls and not to exceed 50 feet for ceilings. 4. Align control joints from ceilings to walls. Control joint shall be a USG 093 Control Joint or equal. Pack mineral wool behind control joints where installed in a fire rated wall. DIVISION 12 – FURNISHINGS 123000 RESIDENTIAL CASEWORK 1. Kitchen and restroom cabinetry shall be manufactured by Smart Cabinety, or approved equal. Model,style, finish, etc. to specified by others. 2. Refer to Unit Interior Elevations for required vanity cabinet heights. 3. Countertops shall be solid surface (specific T.B.D. by others) with eased edges and 4" backsplash, U.N.O. 4. Cabinetry shall be complete with all fillers and hardware. 124920 WINDOW COVERINGS 1. Provide blinds at all exterior windows.(specification by others). 2. Blinds to be equipped with child safety break-away cords. 3. Colors specification by others. DIVISION 22 - PLUMBING (Refer to Hubbell plumbing requirements) The following are accessibility requirements. See sheet G-011 for heights and clearances. 224000 PLUMBING FIXTURES - Operable Parts in Dwelling Units – Plumbing fixture controls, faucets, etc. shall be placed within one or more of the ANSI accessible reach ranges, shall be operable with one hand & shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be 5.0 pounds maximum. (ICC A117.1 2009 Sec. 309) Exceptions include: where redundant controls are provided for a single element, one control in each space shall not be required to be accessible; reset buttons and shut-offs serving piping & plumbing fixtures.(ICC A117.1 2009 Sec. 1003.9) 224016 LAVATORIES & SINKS The Dip of the overflow shall not be considered in determining knee and toe clearance. The front of lavatories & sinks shall be 34” maximum above the floor, measured to the higher of the rim or counter surface. A lavatory in a toilet or bathing facility for a single occupant, accessed only thru a private office & not for common use or public use shall not be required to meet 34” height max. (ICC A117.1 2009 Sec. 606) Water supply & drainpipes under lavatories & sinks shall be insulated or otherwise configured to protect against contact. There shall be no sharp or abrasive surfaces under lavatories. (ICC A117.1 2009 Sec. 606.6) 22 40 13 WATER CLOSETS , URINALS, & BIDETS Water Closets: The required clearance around the water closet shall be permitted to overhang the water closet, associated grab bars, paper dispensers, coat hooks, shelves, accessible routes, color floor space required at other fixtures, and the wheelchair turning space. No other fixtures or obstructions shall be located within the required clearance. The top of the water closet seat shall be 15” minimum & 19” maximum above the floor, measured to the top of the seat. Flush controls shall be hand operated located on the open side of the water closet. No grab bars required, unless requested, in Type A, B or C Dwelling & Sleeping Units, but reinforcement for future installation required in Type A & B Units.(ICC A117.1 2009 Sec. 1003.11.2.4) 22 40 19 BATHTUBS A permanent seat at the head end of the bathtub or a removable in-tub seat shall be provided & meet ANSI requirements. No seat required, unless requested, in Type A, B or C Dwelling & Sleeping Units, but reinforcement for future installation required in Type A & B Units. Grab bars shall be provided on back wall, control end wall & head end wall. No grab bars required, unless requested, in Type A, B or C Dwelling Units, but reinforcement for future installation required in Type A & B Units. (ICC A117.1 2009 Sec. 607) 22 40 23 SHOWER RECEPTORS & BASINS Shower: A permanent seat at the head end of the shower or a removable in-shower seat shall be provided & meet ANSI requirements. No seat required, unless requested, in Type A, B or C Dwelling Units, but reinforcement for future installation required in Type A & B Units. Grab bars shall be provided on back wall, control end wall & head end wall. No grab bars required, unless requested, in Type A, B or C Dwelling Units, but reinforcement for future installation required in Type A & B Units. (ICC A117.1 2009 Sec. 608) DIVISION 23 - HEATING, VENTILATING, AND AIR CONDITIONING DIVISION 26 – ELECTRICAL DIVISION 27 – COMMUNICATIONS DIVISION 28 – ELECTRONIC SAFETY AND SECURITY (Refer to Hubbell requirements) GENERAL: 1. Operable Parts – Tenent controls shall be placed within one or more of the ANSI accessible reach ranges, typically, 48”AFF maximum to top of all controls, shall be operable with one hand & shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be 5.0 pounds maximum. A. (ICC A117.1 2009 Sec. 309) Exceptions include: a. HVAC diffusers; controls mounted on ceiling fans; where redundant controls are provided for a single element, one control in each space shall not be required to be accessible; reset buttons and shut-offs serving piping. (ICC A117.1 2009 Sec. 1003.9) b. Receptacle outlets serving a dedicated use; where two or more receptacle outlets are provided in a kitchen above a length of counter top that is uninterrupted by a sink or appliance, one receptacle outlet shall not be required to comply; floor receptacle outlets, controls mounted on ceiling fans; where redundant controls other than light switches are provided for a single element, one control in each space shall not be required to be accessible; electrical panelboards shall not be required to comply with the one hand, tight grasping, pinching, twisting or force requirements. (ICC A117.1 2009 Sec. 1003.9) c. Where redundant controls are provided for a single element, one control in each space shall not be required to be accessible DIVISION 31 – EARTHWORK (Refer to Civil & Geotechnical documents) GENERAL: 1. Provide excavation, backfill and fine grading for the building, paved areas, and proper site drainage. 2. Provide silt fence, clearance of trees, grubbing of stumps, curb removal, stripping of topsoil, excavation and backfill for foundations, place sand cushion for slabs on grade, grading for paving and re- spreading of top soil. 3. Provide site landscaping i.e., seeding, sodding, spreading on site topsoil, trees, mulch, edging, and shrubbery. 4. Exterior grading to be 4" lower than adjacent interior finish floor, sloping away from building. DIVISION 32 - EXTERIOR IMPROVEMENTS (Refer to Civil & Geotechnical documents) 32 10 00 PAVING 32 80 00 IRRIGATION: (not required) DIVISION 33 – UTILITIES (Refer to Civil documents) GENERAL: 1. All utilities should be sized and expandable to include all future tenants. 2. All utilities shall be stubbed to within 5 feet of the building per Civil/Site engineering documents unless otherwise specified. 3. All utilities shall be adequately sized and spaced to eliminate any overflow and/or backup. 331000 WATER UTILITIES Provide separate domestic water supply service as required from water main to house service meter with irrigation meter in valve room. 333000 SANITARY SEWERAGE UTILITIES - Provide sanitary sewer discharge service as required from under building slab to sanitary sewerage main. 334000 STORM DRAINAGE UTILITIES - Provide storm water discharge service as required from building and/or adjacent to building to storm water main or thru detention area. 335100 NATURAL-GAS UTILITIES - Provide natural gas supply service as required from natural gas main to meter/manifold location at building. 337000 ELECTRICAL UTILITIES - Provide electric supply service as required from electric main to transformer location. Provide appropriately sized transformer and concrete pad as required. NOTE: Electric sub- contractor shall calculate & verify the required size of the service/transformer with utility company. 338000 COMMUNICATIONS UTILITIES - Provide conduits from public R.O.W. to the buildings designated location for the required communications. DIVISION 34 – 39 (Not Used) End of Specification Notes DIVISION 10 – SPECIALTIES (cont.) 10 28 00 TOILET, BATH, AND LAUNDRY ACCESSORIES - (Refer to Unit Plans) Provide toilet paper dispensers and towel bars in each bathroom. 10 55 00 POSTAL SPECIALTIES – Provide ADA mailboxes & parcel boxes manufactured to USPS specifications for all multi-family projects. 10 57 00 CLOSET SPECIALTIES – (Refer to notes on Unit Plans and millwork details)Rev. #Issue / RevisionDate330% Set12-03-2021 ALL FIXTURES TO BE MOUNTED WITHIN ALLOWABLE RANGES AS INDICATED BY ADA ACCESSIBILITY GUIDELINES AND LOCAL CODES. (ALL MOUNTING HEIGHTS INDICATED ARE ABOVE FINISHED FLOOR LEVEL.) ALL GRAB BARS TO BE 1.25"-1.5" DIA. WITH GRIPPABLE SURFACE. SINK HEIGHTS SINK HEIGHTS W/MIRROR TOILET HEIGHTS URINAL HEIGHT PAPER TOWEL DISPENSER HEIGHT TOILET PAPER DISPENSER HEIGHT NAPKIN DISPOSAL HEIGHT BABY CHANGING STATION HEIGHT CLOTHES HOOKS HEIGHT ELECTRIC HAND DRYER34" MIN. 48" MAX.19"34"38" - 48"LATCHING MECHANISM54" MAX. TO27" MIN.9" MIN.17" MIN.34" MAX.6" MAX.34" MAX.40" MAX.39" - 41" 12" 42" MIN.39" - 41"MIN.18"17" - 19"36" 6" 18"33" - 36"17" - 19"17"25"34" MIN. 48" MAX.DRINKING FOUNTAIN SPOUT LOCATION (ANSI ICC A117.1-2009 FIG. 602.5a&b) TOE CLEARANCE (ANSI ICC A117.1-2009 FIG. 306.2) KNEE CLEARANCE (ANSI ICC A117.1-2009 FIG. 306.3) Shall install 2-Hi & Low or 1 that complies for people who use a wheelchair and standing person (2006 IBC Section 1109.5.1)36" MAX.15" MIN.43" MAX.15" MIN.CLEAR FLOOR 30" CLEAR FLOOR 30" CLEAR FLOOR 48"WHEELCHAIR36" MAXSTANDING38"-43"15" MIN. 5" MAX.ACTIVATION DEVICE48" MAX. TOPUSH PUSH 36" MAX.SPOUT HGT.43" MAX.SPOUT HGT.24" MIN.19" MAX.14" MIN.1 1/2" MIN.TP DISPENSER 42" MAX. 60" DIAMETER SPACE T-SHAPED SPACE FOR 180° TURNS MIN. 12" 36" MIN. MIN. 12"36" MIN.60" MIN.60" MIN. (a) (b) CORRIDOR OR OTHER CIRCULATION SPACE CARPET PILE THICKNESSWALKING PARALLEL TO A WALL SIGN OR OBSTRUCTION CANE RANGE WALL PERPENDICULAR TO A WALL EXAMPLE OF PROTECTION AROUND WALL-MOUNTED OBJECTS AND MEASUREMENTS OF CLEAR WIDTHS PROTRUDING OBJECTS HANGING ON WALL WITH LEADING EDGES ABOVE 27" WING WALLS DOWN TO FLOORADDITIONAL PROTECTION NOT REQUIRED BETWEEN WING WALLS (a)(b)(c) (d)80"4"x > 27"x < 27"ANY AMOUNT CLEAR WIDTH.27"CONT. PASSAGE36" MIN. CLEARPASSAGE32" MIN. CLR4"1/2" MAXMINIMUM CLEAR WIDTH FOR SINGLE WHEELCHAIR MINIMUM CLEAR WIDTH FOR TWO WHEELCHAIRS 36" MIN.60" MIN. 32" MIN.FOR MIN. CLEARANCE24" MAX.LATCH SIDE APPROACHES - SWINGING DOORS NOTE: ALL DOORS IN ALCOVES SHALL COMPLY WITH THE CLEARANCES FOR FRONT APPROACHES. NOTE: Y = 48" MINIMUM IF DOOR HAS CLOSER. PUSH SIDE NOTE: Y = 48" MINIMUM IF DOOR HAS BOTH A LATCH AND CLOSER. NOTE: Y = 54" MINIMUM IF DOOR HAS CLOSER. PULL SIDE PULL SIDE HINGE SIDE APPROACHES - SWINGING DOORS NOTE: X = 36" MINIMUM IF Y = 60"; X = 42" MINIMUM IF Y = 54". FRONT APPROACHES - SWINGING DOORS PUSH SIDE NOTE: X = 12" IF DOOR HAS BOTH A CLOSER AND A LATCH. PULL SIDE PUSH SIDE Y(b) (a) (c) 54" MIN.Y42" MIN.Y48" MIN.24" MIN. X 24" MIN.Y42" MIN.60"18"48"X X Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.SAA C:\Users\spoole\Documents\21113 Converge NW, Waukee, IA_3&4-Plex One-Story Townhouse_spoolePMDSN.rvt12/2/2021 3:26:31 PMCONVERGE NWTOWNHOUSESWAUKEE, IOWA21113 G-011 ACCESSIBILITY REQUIREMENTS & GUIDELINES SP SCALE:1/4" = 1'-0"1 FIXTURE MOUNTING HEIGHT SCALE:1/4" = 1'-0"2 WHEELCHAIR TURNING SPACE SCALE:1/4" = 1'-0"6 PROTRUDING OBJECTS SCALE:1/4" = 1'-0"4 MINIMUM CLEAR WIDTHS SCALE:1/4" = 1'-0"3 CLEARANCES @ DOORS ACCESSIBILITY GUIDELINES & REQUIREMENTS Code Referenced: 2010 ADA Standards for Accessible Design Dept. of Justice published revised regulations on September 15, 2010 to set minimum enforceable accessibility standards/requirements for newly designed & constructed or altered State and local government facilities, public accommodations, and commercial facilities after March 15, 2012. Code Referenced: Chapter 11, 2018 INTERNATIONAL BUILDING CODE (IBC) Buildings and facilities shall be designed and constructed to be accessible in accordance with this code and ICC/ANSI A117.1-2009 (Section 1101.2). 301 General 301.1 Scope. Floor and ground surfaces shall be stable, firm, and slip resistant and shall comply with 302. CHAPTER 3: BUILDING BLOCKS 302 Floor or Ground coverings 302.2 Carpet. Carpet or carpet tile shall be securely attached and shall have a firm cushion, pad, or pad. Carpet or carpet tile shall have a level loop, textured loop, level cut pile, or level cut/ uncut pile texture. Pile height shall be 1/2 inch (13 mm) maximum. Exposed edges of carpet shall be fastened to floor surfaces and shall have trim on the entire length of the exposed edge. Carpet edge trim shall comply with 303. 302.3 Openings. Openings in floor or ground surfaces shall not allow passage of a sphere more than 1/2 inch (13 mm) diameter except as allowed in 407.4.3, 409.4.3, 410.4, 810.5.3 and 810.10. Elongated openings shall be placed so that long dimension is perpendicular to the dominant direction of travel. 303 Changes in Level 303.1 General. Where changes in level are permintted in floor or ground surfaces, they shall comply with 303 EXCEPTIONS: 1. Animal containment areas shall not be required to comply with 303. 2. Areas of sports activity shall ot be required to comply with 303. 303.2 Vertical. Changes in level 1/4 inch (6.4 mm) high maximum shall be permitted to be vertical. 303.3 Beveled. Changes in level between 1/4 inch (6.4 mm) high minimum an 1/2 inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2. Advisory 303.3 Beveled. A change in level 1/2 inch (13 mm) is permitted to 1/4 inch (6.4 mm) vertical plus 1/4 inch (6.4 mm) beveled. However, in no case may the combined change in level exceed 1/2 inch (13 mm). changes in level exceeding 1/2 inch (13 mm) must comply with 405 (Ramps) or 406 (Curb Ramps). 303.4 Ramps. Changes in level greater than 1/2 inch (13 mm) high shall be ramped, and shall comply with 405 or 406. 304 Turning Space 304.1 General Turning space shall comply with 304. EXCEPTIONS: Slopes not steeper than 1:48 shall be permitted. 304.2 Floor or Ground Surfaces. Floor or ground surfaces of a turning space shall comply with 302. Changes in level are not permited. Advisory 304.2 Floor or Ground Surface Exception. As used in this section, the phrase "changes in lev el" refers to surfaces with slopes and to surfaces with abrupt rise exceeding that permitted in Section 303.3. Such changes in level are prohibited in required clear floor and ground spaces, turning spaces, and in similar spaces where people using wheelchairs and other mobility devices must park their mobility aids such as in wheelchair spaces, or maneuver those elements such as at doors, fixtures, and telephones. The exception permits slopes not steeper than 1:48. 304.3 Size. Turning space shall comply with 304.3.1 or 304.3.2. 304.3.1 Circular Space. Turning space shall be a space of 60 inches (1525 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with 306. 304.3.2 T-Shaped Space The turning space shall be a T-shaped space within a 60 inch (1525 mm) square minimum with arms and base 36 inches (915 mm) wide minimum. Each arm of the T shall be clear of obstructions 12 inches (304 mm) minimum in each direction and the base shall be clear of obstruction 24 inches (610 mm) minimum. The space shall be permitted to include knee and toe clearance complying with 306 only at the end of either the base or one arm. 304.4 Door Swing. Doors shall be permitted to swing into turning spaces. 305 Clear Floor or Ground Space 305.1 General Clear floor or ground space shall comply with 305. EXCEPTIONS: Slopes not steeper than 1:48 shall be permitted. 305.2 Floor or Ground Surfaces. Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted. 305.3 Size. The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum. 305.5 Position. Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element. 305.7.1 Forward Approach. Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). 305.4 Knee and Toe Clearance. Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with 306. 305.6 Approach. One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space. 305.7 Maneuvering Clearance. Where a clear floor space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with 305.7.1 and 305.7.2. 305.7.2 Parallel Approach. Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). 306 Knee and Toe Clearance 306.1 General. Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with 306. Additional space shall not be prohibited beneath an element but shall not be considered as part of the clear floor or ground space or turning space. Advisory 306.1 General. Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element. When determining clearance under an object for required turning or maneuvering space, care should be taken to ensure the space is clear of any obstructions. 306.2 Toe Clearance. 306.2.1 General. Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2. 306.2.2 Maximum Depth. Toe clearance shall extend 25 inches (635 mm) maximum under an element. 306.2.3 Minimum Required Depth. Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element. 306.2.4 Additional Clearance. Space extending greater than 6 inches (150 mm) beyond the available knee clearance at 9 inches (230 mm) above the finish floor or ground shall not be considered toe clearance. 306.2.5 Width. Toe clearance shall be 30 inches (760 mm) wide minimum. 306.3 Knee Clearance. 306.3.1 General. Space under an element between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground shall be considered knee clearance and shall comply with 306.3. 306.3.2 Maximum Depth. Knee clearance shall extend 25 inches (365 mm) maximum under an element at 9 inches (230 mm) above the finish floor or ground. 306.3.3 Minimum Required Depth. Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor or ground, and 8 inches (205 mm) deep minimum at 27 inches (685 mm) above the finish floor or ground. 306.3.4 Clearance Reduction. Between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground, the knee clearance shall be permited to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches (150mm) in height. 308 Reach Ranges 308.1 General. Reach ranges shall comply with 308. 308.2 Forward Reach. Advisory 308.1 General The folowing table provides guidance on reach ranges for children according to age where building elements such as hooks, lockers, or operable parts are designed for use primarily by children. These dimensions apply to either forward or side reaches. Accessible elements and operable parts designed for adult use or children over age 12 can be located outside these ranges but must be within the adule reach ranges required by 308. 308.2.1 Unobstructed. Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or ground. Children's Reach Ranges Forward or Side Reach Ages 3 and 4 Ages 5 through 8 Ages 9 through 12 High (maximum)36 in (915 mm)40 in (1015 mm)44 in (1120 mm) Low (minimum)20 in (510 mm)18 in (455 mm)16 in (405 mm) 308.2.2 Obstructed High Reach. Where a high reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction. The high forward reach shall be 48 inches (1120 mm) maximum where the reach depth is 20 inches (510mm) maximum. Where the reach depth exceeds 20 inches (150 mm) , the high reach shall be 44 inches (1120 mm) maximum and the reach depth shall be 25 inches (635 mm) maximum. 308.3 Side Reach. 308.3.1 Unobstructed. Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side shall be 15 inches (380 mm) minimum above the finish floor or ground. EXCEPTIONS: 1. An obstruction shall be permitted between the clear floor and ground space and the element where the depth of the obstruction is 10 inches (255 mm) maximum. 2. Operable parts of fuel dispensers shall be permitted to be 54 inches (1370 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs. 308.3.2 Unobstructed High Reach. Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum and the depth of the obstruction shall be 24 inches (610 mm) maximum. The high side reach shall be 48 inches (1220 mm) maximum for a reach depth of 10 inches (225 mm) maximum. Where the reach depth exceeds 10 inches (255 mm), the high side reach shall be 46 inches (117 mm) maximum for a reach depth of 24 inche (610 mm) maximum. EXCEPTIONS: 1. The top of washing machines and clothes dryers shall be permitted to be 36 inches (915 mm) maximum above the finish floor. 2. Operable parts of fuel dispensers shall be permitted to be 54 inches (1370 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs. 309 Operable Parts 309.1 General. Operable parts shall comply with 309. 309.2 Clear floor space. A clear floor space complying with 305 shall be provided. 309.3 Height. Operable parts shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be 5 pounds (22.2N) maximum. 307 Protruding Objects 307.1 General. Protruding objects shall comply with 307. 307.2 Protrusion Limits. Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into the circulation path. EXCEPTION: Handrails shall be permitted to protrude 4 1/2 inches (115 mm) maximum. Advisory 307.2 Protrusion Limits. When a cane is used and the element is in the detectable range, it gives a person suffecient time to detect the element with the cane before there is body contact. Elements located on circulation paths, including operable elements, must comply with requirements for protruding objects. For example, awnings and their supporting structures cannot reduce the minimum required vertical clearance. Similarly, casement windows, when open, cannot encroach more than 4 inches (100 mm) into the circulation path above 27 inches (685 mm). 307.3 Post-Mounted Objects. Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (685 mm) minimum and 80 inches (2030 mm) maximum above the finish floor or ground. Where a sign or other obstruction is mounted between posts or pylons and the clear distance between the posts or pylons is greater than 12 inches (305 mm), the lowest edge of such sign or obstruction shall be 27 inches (685 mm) maximum or 80 inches (2030 mm) minimum above the finish floor or ground. EXCEPTION: The sloping portions of handrails serving stairs and ramps shall not be required to comply with 307.3. EXCEPTION: Door closers and door stops shall be permited to be 78 inches (1980 mm) minimum above the finish floor or ground. 307.4 Vertical Clearance. Vertical clearance shall be 80 inches (2030 mm) high mimimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2030 mm) high. The leading edge of such guardrail or barrier shall be located 27 inches (685 mm) maximum above the finish floor or ground. 307.5 Required Clear Width Protruding objects shall not reduce the clear width required for accessible routes.Rev. #Issue / RevisionDate330% Set12-03-2021 DW REF. W D W D DW REF. WD DW REF. DW REF. W D W D DW REF. DW REF. WD REF.WDDW 5482 SF FIRST FLOOR 7309 SF FIRST FLOOR (TYPE B)(TYPE B)(TYPE B)(TYPE B) Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.SAA C:\Users\spoole\Documents\21113 Converge NW, Waukee, IA_3&4-Plex One-Story Townhouse_spoolePMDSN.rvt12/2/2021 3:26:33 PMCONVERGE NWTOWNHOUSESWAUKEE, IOWA21113 G-101 3/4-PLEX 1-STORY CODE REVIEW SP BUILDING SUMMARY DRIVING CODE REVIEW USE & OCCUPANCY TYPE OF CONSTRUCTION AREA FIRE SPRINKLER & TYPE ENERGY CODE METHOD IRC/R-3 CHAPTER 11 IBC VB 0 SF NFPA 13R PRESCRIPTIVE 2018 IRC CODE ANALYSIS The following is not intended to be an all inclusive list, but rather a general summary. Code Referenced: 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) CODE SUMMARY: CHAPTER 1 –SCOPE AND ADMINISTRATION Scope (Section R101.2):The provisions of the International Residential Code for One-and Two-Family Dwellings shall apply to the construction, alterations, movement, enlargement, replacement, repair, equipment, use and occupancy, location removal and demolition of detached one-and two-family dwellings and townhouses not more than three storied above grade plan in height with separate means of egress and their accessory structures, CHAPTER 3 –BUILDING PLANNING Fire-Resistant Construction (Section R302): Exterior Walls (Section R302.1 & Table R302.1(1)):>5' NO EXTERIOR ELEMENT RATINGS REQUIRED Townhouses (Section R302.2): Common Wall (Section 302.2.2):NO SPRINKLER = 2 HOUR RATING Such walls do not contain plumbing or mechanical equipment, ducts or vents in the cavity of the wall. Wall shall be rated for fire exposure from both sides and shall extend continuous from the foundation to the underside of the roof sheathing. Dwelling/Garage Opening/Penetration Protection (Section R302.5): Opening Protection (Section R302.5.1):20 MIN. GARAGE DOOR WITH CLOSER Dwelling/Garage Fire Separation (Section R302.6):>= 5/8" GYP.BD. ON GARAGE SIDE, WALLS AND CEILING Chapter 156, Section 156.02, Item #10 Local Amendments to the Building Code Fireblocking (Section R302.11):FIREBLOCKING REQ'D AT BELOW LOCATIONS 1. Concealed spaces of stud walls and ceiling height. 2. At interconnections between concealed spaces such as occur at soffits. 3. At openings around vents, pipes, ducts, cables and wires at ceiling level. *See Section R302.11.1 for Fireblocking Material Options Draftstopping (Section R302.12):<1000 SF OF CONCEALED SPACE Materials (R302.12.1):>=1/2" GYP. BD. OR >=3/8" WOOD STRUCTURAL PANEL Minimum Room Areas (Section R304): Minimum Area (Section R304.1):ONE ROOM MIN. 120 SF GROSS Other Rooms (Section R304.2):MIN. 70 SF Minimum Dimensions (Section R304.3):MIN. 7 FT IN ANY HORIZONTAL DIMENSIONS Ceiling Height (Section R305):MIN. 7 FT Toilet, Bath and Shower Spaces (Section R307):REFER TO CHAPTER 11 IBC Emergency Escape and Rescue Openings (Section R310): Emergency Escape and Rescue Required (Section R310.1):EACH BEDROOM Emergency Escape and Rescue Openings (Section R310.2): Minimum Opening Area (Section R310.2.1):MIN. 5.7 SF NET OPENING, MIN. 24" CLEAR HEIGHT MIN. 20" CLEAR WIDTH Minimum Sill Height (Section R310.2.2):<44" Means of Egress (Section R311): Egress Door (Section R311.2):MIN. 1 DOOR, SIDE-HINGED, MIN. CLEAR 32" Floors and Landings at Exterior Doors (R311.3):MIN. 36" IN DIRECTION OF TRAVEL, BOTH SIDES OF DOOR Hallways (Section R311.6):MIN. 36" Stairways (Section 311.7): Width (Section 311.7.1):MIN. 36" Headroom (Section 311.7.2):MIN. 80" Vertical Rise (Section 311.7.3):MAX. 151" Treads & Risers (Section R311.7.5):RISER 7 3/4" MAX.; TREADS 10" MIN. Landing (Section R311.7.6):WIDTH = STAIR A WIDTH; DEPTH = 36" MIN. Stairways Walking Surface (Section R311.7.7):MAX 2% SLOPE Handrails (Section R311.7.8):MIN. ONE SIDE Height (Section R311.7.8.1):BETWEEN 34"-38" Guards and Window Fall Protection (Section R312): Guards (Section R312.1): Where Required(Section R312.1.1):>=36" TO FLOOR/GRADE BELOW Height (Section R312.1.2):MIN. 36" Opening Limitations (Section R312.1.3):<4" Window Fall Protection (Section R312.2): Window Sill (Section R312.2.1):> 72" ABOVE GRADE; MIN. 24" ABOVE FLOOR Window Opening Control Device:<4" OPENING COMPLYING WITH ASTM F 2090 Automatic Fire Sprinkler System (Section R313): Townhouses Automatic Fire Sprinkler Systems (Section R313.1):SPRINKLER NOT REQUIRED Chapter 156, Section 156.02, Item #25 Local Amendments to the Building Code EXCEPTION #2: 8 OR LESS DWELLING UNITS EXCEPTION #3: <18,000 SF FLOOR SPACE EXCLUSIVE OF ANY GARAGE Smoke Alarms (Section R314): Smoke Detection Systems (Section R314.2): PER NFPA 72 Locations (Section R314.2): 1. Each sleeping room 2. Outside each separate sleeping area in the immediate vicinity of the bedrooms 3. On each additional story of the dwelling Carbon Monoxide Alarms (Section R315): Carbon Monoxide Alarms (Section R315.1):OUTSIDE EACH SEPARATE SLEEPING AREA Carbon Monoxide Detection (Section R315.2):PER NFPA 720 Site Address (Section R319): Buildings shall have approved address numbers that are plainly legible and visible from the street. Shall be contrasting with their background. Shall be a minimum of 4" high with Minimum stroke of 1/2". Accessibility (Section R320):>=4 UNITS = REFER TO CHAPTER 11 OF IBC FOR R-3 The following is not intended to be an all inclusive list, but rather a general summary. Code Referenced: 2018 INTERNATIONAL BUILDING CODE (IBC) CHAPTER 11 -ACCESSIBILITY Dwelling Units and Sleeping Units (Section 1107): Accessible Spaces (Section 1107.3):ROOMS OR SPACES USED BY RESIDENTS SERVING TYPE A OR TYPE B UNITS SHALL BE ACCESSIBLE Accessible Route (Section 1007.4):AT LEAST ONE ROUTE SHALL CONNECT TO ENTRANCE OF EACH TYPE A AND TYPE B UNIT AND WITH THOSE EXTERIOR AND INTERIOR SPACE OF THE UNIT. Group R-3 (Section 1107.6.3):ALL DWELLING UNITS IN STRUCTURES OF FOUR OR MORE DWELLING UNITS = TYPE B General Exceptions (Section 1007.7): Multistory Units (Section 1107.7.2):2 STORY UNITS = NOT TYPE B Other Features and Facilities (Section 1109): General (Section 1109.1):TYPE B UNIT SHALL COMPLY WITH CHAPTER 10 OF ICC A117.1 2018 IBC CODE ANALYSIS FIRE RATING LEGEND ONE HOUR RATED WALL TWO HOUR PARTY WALL Code Referenced: 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) Climate Zone, Moisture Regimes, and Warm-Humid Designations (Figure & Table 301.1): POLK COUNTY, IOWA -5A Commercial Energy Efficiency (Chapter 4): These commercial buildings shall meet either the requirements of ASHRAE/IESNA Standard 90.1, Energy Standard for Buildings Except for Low- Rise Residential Buildings, or the requirements contained in this Chapter. (Section 501.1) Building Envelope Requirements -Opaque Thermal Envelope Requirements (Table C402.1.3): All other than Group R Roofs Insulation entirely above deck R-25ci (ci=Continuous Insulation) Attic and other R38 Walls, Above Grade Other R-13 + R-3.8ci or R-20 Below grade wall R-7.5ci (ci=Continuous Insulation) Slab-on-Grade Floors Heated slabs R-15 for 36" below Swinging doors U -0.37 Roll-up or sliding doors R-4.75 Building Envelope Requirements: Fenestration (Table 402.4): All other than Group R Vertical fenestration U-Factor Fixed fenestration 0.38 Operable fenestration 0.45 Entrance door 0.77 SHGC SHGC 0.40 2012 INT'L ENERGY CONSERVATION CODE ANALYSIS VARIES NORTHRev. #Issue / RevisionDate330% Set12-03-2021SCALE:1/16" = 1'-0"1 3-PLEX 1-STORY FIRST FLOOR CODE PLAN SCALE:1/16" = 1'-0"2 4-PLEX 1-STORY FIRST FLOOR CODE PLAN NORTH ORIENTATION VARIES - REFER TO CIVIL REF.WDDW REF. WD DW REF.WDDW REF. WD DW REF. WD DW8837 SF FIRST FLOOR (TYPE B) (TYPE B)(TYPE B)(TYPE B) (TYPE B) Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.SAA C:\Users\spoole\Documents\21113 Converge NW, Waukee, IA_5-Plex One-Story Townhouse_spoolePMDSN.rvt12/2/2021 3:22:46 PMCONVERGE NWTOWNHOUSESWAUKEE, IA21113 G-102 5-PLEX 1-STORY CODE REVIEW SP SCALE:1/16" = 1'-0"1 1-STORY TOWNHOUSE CODE PLAN BUILDING SUMMARY DRIVING CODE REVIEW USE & OCCUPANCY TYPE OF CONSTRUCTION AREA FIRE SPRINKLER & TYPE ENERGY CODE METHOD IRC/R-3 CHAPTER 11 IBC VB 8837 SF NFPA 13R PRESCRIPTIVE 2018 IRC CODE ANALYSIS The following is not intended to be an all inclusiv e list, but rather a general summary. Code Referenced: 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) CODE SUMMARY: CHAPTER 1 –SCOPE AND ADMINISTRATION Scope (Section R101.2):The provisions of the International Residential Code for One-and Two-Family Dwellings shall apply to the construction, alterations, movement, enlargement, replacement, repair, equipment, use and occupancy, location removal and demolition of detached one-and two-family dwellings and townhouses not more than three storied above grade plan in height with separate means of egress and their accessory structures, CHAPTER 3 –BUILDING PLANNING Fire-Resistant Construction (Section R302): Exterior Walls (Section R302.1 & Table R302.1(1)):>5' NO EXTERIOR ELEMENT RATINGS REQUIRED Townhouses (Section R302.2): Common Wall (Section 302.2.2):NO SPRINKLER = 2 HOUR RATING Such walls do not contain plumbing or mechanical equipment, ducts or vents in the cavity of the wall. Wall shall be rated for fire exposure from both sides and shall extend continuous from the foundation to the underside of the roof sheathing. Dwelling/Garage Opening/Penetration Protection (Section R302.5): Opening Protection (Section R302.5.1):20 MIN. GARAGE DOOR WITH CLOSER Dwelling/Garage Fire Separation (Section R302.6):>= 5/8" GYP.BD. ON GARAGE SIDE, WALLS AND CEILING Chapter 156, Section 156.02, Item #10 Local Amendments to the Building Code Fireblocking (Section R302.11):FIREBLOCKING REQ'D AT BELOW LOCATIONS 1. Concealed spaces of stud walls and ceiling height. 2. At interconnections between concealed spaces such as occur at soffits. 3. At openings around vents, pipes, ducts, cables and wires at ceiling level. *See Section R302.11.1 for Fireblocking Material Options Draftstopping (Section R302.12):<1000 SF OF CONCEALED SPACE Materials (R302.12.1):>=1/2" GYP. BD. OR >=3/8" WOOD STRUCTURAL PANEL Minimum Room Areas (Section R304): Minimum Area (Section R304.1):ONE ROOM MIN. 120 SF GROSS Other Rooms (Section R304.2):MIN. 70 SF Minimum Dimensions (Section R304.3):MIN. 7 FT IN ANY HORIZONTAL DIMENSIONS Ceiling Height (Section R305):MIN. 7 FT Toilet, Bath and Shower Spaces (Section R307):REFER TO CHAPTER 11 IBC Emergency Escape and Rescue Openings (Section R310): Emergency Escape and Rescue Required (Section R310.1):EACH BEDROOM Emergency Escape and Rescue Openings (Section R310.2): Minimum Opening Area (Section R310.2.1):MIN. 5.7 SF NET OPENING, MIN. 24" CLEAR HEIGHT MIN. 20" CLEAR WIDTH Minimum Sill Height (Section R310.2.2):<44" Means of Egress (Section R311): Egress Door (Section R311.2):MIN. 1 DOOR, SIDE-HINGED, MIN. CLEAR 32" Floors and Landings at Exterior Doors (R311.3):MIN. 36" IN DIRECTION OF TRAVEL, BOTH SIDES OF DOOR Hallways (Section R311.6):MIN. 36" Stairways (Section 311.7): Width (Section 311.7.1):MIN. 36" Headroom (Section 311.7.2):MIN. 80" Vertical Rise (Section 311.7.3):MAX. 151" Treads & Risers (Section R311.7.5):RISER 7 3/4" MAX.; TREADS 10" MIN. Landing (Section R311.7.6):WIDTH = STAIR A WIDTH; DEPTH = 36" MIN. Stairways Walking Surface (Section R311.7.7):MAX 2% SLOPE Handrails (Section R311.7.8):MIN. ONE SIDE Height (Section R311.7.8.1):BETWEEN 34"-38" Guards and Window Fall Protection (Section R312): Guards (Section R312.1): Where Required(Section R312.1.1):>=36" TO FLOOR/GRADE BELOW Height (Section R312.1.2):MIN. 36" Opening Limitations (Section R312.1.3):<4" Window Fall Protection (Section R312.2): Window Sill (Section R312.2.1):> 72" ABOVE GRADE; MIN. 24" ABOVE FLOOR Window Opening Control Device:<4" OPENING COMPLYING WITH ASTM F 2090 Automatic Fire Sprinkler System (Section R313): Townhouses Automatic Fire Sprinkler Systems (Section R313.1):SPRINKLER NOT REQUIRED Chapter 156, Section 156.02, Item #25 Local Amendments to the Building Code EXCEPTION #2: 8 OR LESS DWELLING UNITS EXCEPTION #3: <18,000 SF FLOOR SPACE EXCLUSIVE OF ANY GARAGE Smoke Alarms (Section R314): Smoke Detection Systems (Section R314.2): PER NFPA 72 Locations (Section R314.2): 1. Each sleeping room 2. Outside each separate sleeping area in the immediate vicinity of the bedrooms 3. On each additional story of the dwelling Carbon Monoxide Alarms (Section R315): Carbon Monoxide Alarms (Section R315.1):OUTSIDE EACH SEPARATE SLEEPING AREA Carbon Monoxide Detection (Section R315.2):PER NFPA 720 Site Address (Section R319): Buildings shall have approved address numbers that are plainly legible and visible from the street. Shall be contrasting with their background. Shall be a minimum of 4" high with Minimum stroke of 1/2". Accessibility (Section R320):>=4 UNITS = REFER TO CHAPTER 11 OF IBC FOR R-3 The following is not intended to be an all inclusive list, but rather a general summary. Code Referenced: 2018 INTERNATIONAL BUILDING CODE (IBC) CHAPTER 11 -ACCESSIBILITY Dwelling Units and Sleeping Units (Section 1107): Accessible Spaces (Section 1107.3):ROOMS OR SPACES USED BY RESIDENTS SERVING TYPE A OR TYPE B UNITS SHALL BE ACCESSIBLE Accessible Route (Section 1007.4):AT LEAST ONE ROUTE SHALL CONNECT TO ENTRANCE OF EACH TYPE A AND TYPE B UNIT AND WITH THOSE EXTERIOR AND INTERIOR SPACE OF THE UNIT. Group R-3 (Section 1107.6.3):ALL DWELLING UNITS IN STRUCTURES OF FOUR OR MORE DWELLING UNITS = TYPE B General Exceptions (Section 1007.7): Multistory Units (Section 1107.7.2):2 STORY UNITS = NOT TYPE B Other Features and Facilities (Section 1109): General (Section 1109.1):TYPE B UNIT SHALL COMPLY WITH CHAPTER 10 OF ICC A117.1 2018 IBC CODE ANALYSIS FIRE RATING LEGEND ONE HOUR RATED WALL TWO HOUR PARTY WALL Code Referenced: 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) Climate Zone, Moisture Regimes, and Warm-Humid Designations (Figure & Table 301.1): POLK COUNTY, IOWA -5A Commercial Energy Efficiency (Chapter 4): These commercial buildings shall meet either the requirements of ASHRAE/IESNA Standard 90.1, Energy Standard for Buildings Except for Low- Rise Residential Buildings, or the requirements contained in this Chapter. (Section 501.1) Building Envelope Requirements -Opaque Thermal Envelope Requirements (Table C402.1.3): All other than Group R Roofs Insulation entirely above deck R-25ci (ci=Continuous Insulation) Attic and other R38 Walls, Above Grade Other R-13 + R-3.8ci or R-20 Below grade wall R-7.5ci (ci=Continuous Insulation) Slab-on-Grade Floors Heated slabs R-15 for 36" below Swinging doors U -0.37 Roll-up or sliding doors R-4.75 Building Envelope Requirements: Fenestration (Table 402.4): All other than Group R Vertical fenestration U-Factor Fixed fenestration 0.38 Operable fenestration 0.45 Entrance door 0.77 SHGC SHGC 0.40 2012 INT'L ENERGY CONSERVATION CODE ANALYSIS NORTH Rev. #Issue / RevisionDate330% Set12-03-2021NORTH ORIENTATION VARIES - REFER TO CIVIL REF.WDDW REF.WDDW REF. DW REF. DW WDWD5746 SF FIRST FLOOR (TYPE B)(TYPE B) 2250 SF SECOND FLOOR Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.SAA C:\Users\spoole\Documents\21113 Converge NW, Waukee, IA_4-Plex Two-Story Townhouse_spoolePMDSN.rvt12/2/2021 3:19:21 PMCONVERGE NWTOWNHOUSESWAUKEE, IA21113 G-103 4-PLEX 2-STORY CODE REVIEW SP BUILDING SUMMARY DRIVING CODE REVIEW USE & OCCUPANCY TYPE OF CONSTRUCTION AREA FIRE SPRINKLER & TYPE ENERGY CODE METHOD IRC/R-3 CHAPTER 11 IBC VB 7796 SF NFPA 13R PRESCRIPTIVE 2018 IRC CODE ANALYSIS The following is not intended to be an all inclusiv e list, but rather a general summary. Code Referenced: 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) CODE SUMMARY: CHAPTER 1 –SCOPE AND ADMINISTRATION Scope (Section R101.2):The provisions of the International Residential Code for One-and Two-Family Dwellings shall apply to the construction, alterations, movement, enlargement, replacement, repair, equipment, use and occupancy, location removal and demolition of detached one-and two-family dwellings and townhouses not more than three storied above grade plan in height with separate means of egress and their accessory structures, CHAPTER 3 –BUILDING PLANNING Fire-Resistant Construction (Section R302): Exterior Walls (Section R302.1 & Table R302.1(1)):>5' NO EXTERIOR ELEMENT RATINGS REQUIRED Townhouses (Section R302.2): Common Wall (Section 302.2.2):NO SPRINKLER = 2 HOUR RATING Such walls do not contain plumbing or mechanical equipment, ducts or vents in the cavity of the wall. Wall shall be rated for fire exposure from both sides and shall extend continuous from the foundation to the underside of the roof sheathing. Dwelling/Garage Opening/Penetration Protection (Section R302.5): Opening Protection (Section R302.5.1):20 MIN. GARAGE DOOR WITH CLOSER Dwelling/Garage Fire Separation (Section R302.6):>= 5/8" GYP.BD. ON GARAGE SIDE, WALLS AND CEILING Chapter 156, Section 156.02, Item #10 Local Amendments to the Building Code Fireblocking (Section R302.11):FIREBLOCKING REQ'D AT BELOW LOCATIONS 1. Concealed spaces of stud walls and ceiling height. 2. At interconnections between concealed spaces such as occur at soffits. 3. At openings around vents, pipes, ducts, cables and wires at ceiling level. *See Section R302.11.1 for Fireblocking Material Options Draftstopping (Section R302.12):<1000 SF OF CONCEALED SPACE Materials (R302.12.1):>=1/2" GYP. BD. OR >=3/8" WOOD STRUCTURAL PANEL Minimum Room Areas (Section R304): Minimum Area (Section R304.1):ONE ROOM MIN. 120 SF GROSS Other Rooms (Section R304.2):MIN. 70 SF Minimum Dimensions (Section R304.3):MIN. 7 FT IN ANY HORIZONTAL DIMENSIONS Ceiling Height (Section R305):MIN. 7 FT Toilet, Bath and Shower Spaces (Section R307):REFER TO CHAPTER 11 IBC Emergency Escape and Rescue Openings (Section R310): Emergency Escape and Rescue Required (Section R310.1):EACH BEDROOM Emergency Escape and Rescue Openings (Section R310.2): Minimum Opening Area (Section R310.2.1):MIN. 5.7 SF NET OPENING, MIN. 24" CLEAR HEIGHT MIN. 20" CLEAR WIDTH Minimum Sill Height (Section R310.2.2):<44" Means of Egress (Section R311): Egress Door (Section R311.2):MIN. 1 DOOR, SIDE-HINGED, MIN. CLEAR 32" Floors and Landings at Exterior Doors (R311.3):MIN. 36" IN DIRECTION OF TRAVEL, BOTH SIDES OF DOOR Hallways (Section R311.6):MIN. 36" Stairways (Section 311.7): Width (Section 311.7.1):MIN. 36" Headroom (Section 311.7.2):MIN. 80" Vertical Rise (Section 311.7.3):MAX. 151" Treads & Risers (Section R311.7.5):RISER 7 3/4" MAX.; TREADS 10" MIN. Landing (Section R311.7.6):WIDTH = STAIR A WIDTH; DEPTH = 36" MIN. Stairways Walking Surface (Section R311.7.7):MAX 2% SLOPE Handrails (Section R311.7.8):MIN. ONE SIDE Height (Section R311.7.8.1):BETWEEN 34"-38" Guards and Window Fall Protection (Section R312): Guards (Section R312.1): Where Required(Section R312.1.1):>=36" TO FLOOR/GRADE BELOW Height (Section R312.1.2):MIN. 36" Opening Limitations (Section R312.1.3):<4" Window Fall Protection (Section R312.2): Window Sill (Section R312.2.1):> 72" ABOVE GRADE; MIN. 24" ABOVE FLOOR Window Opening Control Device:<4" OPENING COMPLYING WITH ASTM F 2090 Automatic Fire Sprinkler System (Section R313): Townhouses Automatic Fire Sprinkler Systems (Section R313.1):SPRINKLER NOT REQUIRED Chapter 156, Section 156.02, Item #25 Local Amendments to the Building Code EXCEPTION #2: 8 OR LESS DWELLING UNITS EXCEPTION #3: <18,000 SF FLOOR SPACE EXCLUSIVE OF ANY GARAGE Smoke Alarms (Section R314): Smoke Detection Systems (Section R314.2): PER NFPA 72 Locations (Section R314.2): 1. Each sleeping room 2. Outside each separate sleeping area in the immediate vicinity of the bedrooms 3. On each additional story of the dwelling Carbon Monoxide Alarms (Section R315): Carbon Monoxide Alarms (Section R315.1):OUTSIDE EACH SEPARATE SLEEPING AREA Carbon Monoxide Detection (Section R315.2):PER NFPA 720 Site Address (Section R319): Buildings shall have approved address numbers that are plainly legible and visible from the street. Shall be contrasting with their background. Shall be a minimum of 4" high with Minimum stroke of 1/2". Accessibility (Section R320):>=4 UNITS = REFER TO CHAPTER 11 OF IBC FOR R-3 The following is not intended to be an all inclusive list, but rather a general summary. Code Referenced: 2018 INTERNATIONAL BUILDING CODE (IBC) CHAPTER 11 -ACCESSIBILITY Dwelling Units and Sleeping Units (Section 1107): Accessible Spaces (Section 1107.3):ROOMS OR SPACES USED BY RESIDENTS SERVING TYPE A OR TYPE B UNITS SHALL BE ACCESSIBLE Accessible Route (Section 1007.4):AT LEAST ONE ROUTE SHALL CONNECT TO ENTRANCE OF EACH TYPE A AND TYPE B UNIT AND WITH THOSE EXTERIOR AND INTERIOR SPACE OF THE UNIT. Group R-3 (Section 1107.6.3):ALL DWELLING UNITS IN STRUCTURES OF FOUR OR MORE DWELLING UNITS = TYPE B General Exceptions (Section 1007.7): Multistory Units (Section 1107.7.2):2 STORY UNITS = NOT TYPE B Other Features and Facilities (Section 1109): General (Section 1109.1):TYPE B UNIT SHALL COMPLY WITH CHAPTER 10 OF ICC A117.1 2018 IBC CODE ANALYSIS SCALE:1/16" = 1'-0"1 4-PLEX 2-STORY TOWNHOUSE FIRST FLOOR CODE PLAN SCALE:1/16" = 1'-0"2 4-PLEX 2-STORYTOWNHOUSE SECOND FLOOR CODE PLAN FIRE RATING LEGEND ONE HOUR RATED WALL TWO HOUR PARTY WALL Code Referenced: 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) Climate Zone, Moisture Regimes, and Warm-Humid Designations (Figure & Table 301.1): POLK COUNTY, IOWA -5A Commercial Energy Efficiency (Chapter 4): These commercial buildings shall meet either the requirements of ASHRAE/IESNA Standard 90.1, Energy Standard for Buildings Except for Low- Rise Residential Buildings, or the requirements contained in this Chapter. (Section 501.1) Building Envelope Requirements -Opaque Thermal Envelope Requirements (Table C402.1.3): All other than Group R Roofs Insulation entirely above deck R-25ci (ci=Continuous Insulation) Attic and other R38 Walls, Above Grade Other R-13 + R-3.8ci or R-20 Below grade wall R-7.5ci (ci=Continuous Insulation) Slab-on-Grade Floors Heated slabs R-15 for 36" below Swinging doors U -0.37 Roll-up or sliding doors R-4.75 Building Envelope Requirements: Fenestration (Table 402.4): All other than Group R Vertical fenestration U-Factor Fixed fenestration 0.38 Operable fenestration 0.45 Entrance door 0.77 SHGC SHGC 0.40 2012 INT'L ENERGY CONSERVATION CODE ANALYSIS Rev. #Issue / RevisionDate330% Set12-03-2021NORTH ORIENTATION VARIES - REFER TO CIVIL NORTH ORIENTATION VARIES - REFER TO CIVIL DW REF. W D W D DW REF. WD DW REF. DW REF. W D W D DW REF. DW REF. WD REF.WDDW 10' - 8" 5' - 7" 20' - 1"48' - 0"6' - 0"16' - 8" 19' - 8" 16' - 8" 19' - 8" 19' - 8" 16' - 8"54' - 0"2' - 4" 6' - 0" 2' - 4" 2' - 1"3' - 0" 6"2' - 1" 16' - 0" 2' - 0" A-201 1 A-201 5 A-201 2 A-2016 1' - 9" 6' - 0" 4' - 2" 6' - 0" 1' - 9" 5' - 4" 6' - 0" 5' - 4"20' - 4" 6' - 0" 21' - 8" 6' - 0"SLOPE CONCRETE 1/4" PER FT, TYP6' - 0"3' - 0"SLOPE CONCRETE 1/4" PER FT, TYP6' - 0"45' - 0"3' - 0"2' - 0" 16' - 0" 2' - 1" 6" 3' - 0"2' - 1" 2' - 4" 6' - 0" 2' - 4" 5' - 4" 6' - 0" 5' - 4"6' - 0"21' - 8"6' - 0"20' - 4"19' - 8" 5' - 4" 6' - 0" 5' - 4" 19' - 8" 19' - 8"54' - 0"1/4" PER FT, TYP6' - 0"1' - 9" 6' - 0" 4' - 2" 6' - 0" 1' - 9" 1' - 9"6' - 0"4' - 2"6' - 0" 1' - 9" 20' - 1"5' - 7"10' - 8" 2' - 0"16' - 0"2' - 1" 6" 3' - 0"2' - 1" 2' - 4" 6' - 0" 2' - 4" 20' - 1" 5' - 7" 10' - 8" UNIT 101 TYPE 3B 1730 SF UNIT 102 TYPE 2B+D 1730 SF UNIT 103 TYPE 3B 1730 SF 36' - 4"36' - 4"36' - 4" 109' - 0" 35' - 4 1/8" 11 1/2" 35' - 4 1/2" 11 1/2" 35' - 4 1/8" A-201 3 A-201 4 10' - 8" 5' - 7" 20' - 1"48' - 0"6' - 0"16' - 8" 19' - 8" 16' - 8"39' - 4"16' - 8" 19' - 8" 16' - 8"54' - 0"2' - 4" 6' - 0" 2' - 4" 2' - 1"3' - 0" 6"2' - 1" 16' - 0" 2' - 0" 1' - 8 1/2" 6' - 0" 4' - 1 1/4" 6' - 0" 1' - 9" 5' - 4" 6' - 0" 5' - 4"20' - 4" 6' - 0" 21' - 8" 6' - 0"SLOPE CONCRETE 1/4" PER FT, TYP6' - 0"3' - 0"SLOPE CONCRETE 1/4" PER FT, TYP2' - 0" 16' - 0" 2' - 1" 6" 3' - 0"2' - 1" 2' - 4" 6' - 0" 2' - 4" 5' - 3" 6' - 0"5' - 4" 6' - 0" 5' - 4"39' - 4"1/4" PER FT, TYP6' - 0"1' - 9" 6' - 0" 4' - 1 1/4" 6' - 0" 1' - 8 1/2" 1' - 9"6' - 0"4' - 1 1/4"6' - 0" 1' - 8 1/2" 10' - 8"5' - 7"20' - 1"10' - 8"5' - 7"20' - 1"20' - 1"5' - 7"10' - 8" 2' - 0"16' - 0"2' - 1" 6" 3' - 0"2' - 1" 2' - 4" 6' - 0" 2' - 4" UNIT 101 TYPE 3B 1730 SF UNIT 102 TYPE 2B+D 1730 SF UNIT 103 TYPE 2B+D ALT 1730 SF 36' - 4"36' - 4"36' - 4"36' - 4"6' - 0"45' - 0"3' - 0"2' - 0" 16' - 0" 2' - 1" 6" 3' - 0"2' - 1" 2' - 4" 6' - 0" 2' - 4" 5' - 4" 6' - 0" 5' - 4"6' - 0"21' - 8"6' - 0"20' - 4"54' - 0"1/4" PER FT, TYP6' - 0"1' - 8 1/2" 6' - 0"4' - 1 1/4"6' - 0"1' - 9" UNIT 103 TYPE 3B 1730 SF 145' - 4" A-201 5 A-2016 35' - 4 1/8" 11 1/2" 35' - 4 1/2" 11 1/2" 35' - 4 1/2" 11 1/2" 35' - 4 1/8" Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.SAA C:\Users\spoole\Documents\21113 Converge NW, Waukee, IA_3&4-Plex One-Story Townhouse_spoolePMDSN.rvt12/2/2021 3:26:23 PMCONVERGE NWTOWNHOUSESWAUKEE, IOWA21113 A-101 3/4-PLEX 1-STORY FLOOR PLAN SP SCALE:1/8" = 1'-0"1 1-STORY 3-PLEX FIRST FLOOR Rev. #Issue / RevisionDate330% Set12-03-20211. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL SITE INFO, FURNITURE, FIXTURES AND EQUIPMENT SHOWN SHOULD BE CONSIDERED CONCEPTUAL AND MAY HAVE BE PROVIDED FOR COORDINATION PURPOSES ONLY. REFER TO CIVIL, FIRE SUPPRESSION, PLUMBING, MECHANICAL, ELECTRICAL, COMMUNICATIONS, ELECTRONIC SAFETY & SECURITY DOCUMENTS &/OR CONSULTANTS FOR SPECIFIC DESIGN INFORMATION & REQUIREMENTS. 3. DIMENSIONS ARE TO FACE OF FINISH MATERIAL OR CENTER OF STRUCTURE UNLESS OTHERWISE SPECIFIED. 4. ALL CONDUITS, PIPES, WIRING, ROUGH-IN, ETC. SHOULD BE HELD AS TIGHT AS POSSIBLE TO THE ROOF OR FLOOR DECK OR SHOULD BE KEPT WITHIN INTERIOR WALL CAVITIES. NOTHING SHALL BE BELOW THE BOTTOM EDGE OF MAIN BUILDING FRAMES, NOTHING SHALL BE EXPOSED IN FINISHED SPACES, NOTHING SHALL PREVENT A SMOOTH CONTINUOUS FINISHED WALL OR CEILING AS NOTED ON THE DRAWINGS AND NO PLUMBING RAN IN EXTERIOR WALLS UNLESS PRIOR APPROVAL IS GRANTED BY THE ARCHITECT OR OWNER. PLACEMENT COORDINATION BETWEEN TRADES IS REQUIRED. 5. INSTALL VERTICAL EXPANSION JOINT MINIMAL AT COLUMN/GRID LINES AND AT THE HEAD OF DOOR JAMBS/OPENINGS OR AS OTHERWISE NOTED OR WHERE REQUIRED PER STANDARD MATERIAL PRACTICE TO REDUCE STRESS CRACKING. NO CONTROL JOINT/EXPANSION JOINT IN LOAD BEARING AREAS, STAY AWAY 2'-6" MIN. 6. CAULK & SEAL ALL CONTROL-EXPANSION, SAWCUT JOINTS AT ALL INTERIOR & EXTERIOR MASONRY & CONCRETE. 7. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM BUILDING WITHOUT PONDING OF WATER ADJACENT TO BUILDING OR ON PAVEMENTS. GENERAL FLOOR PLAN NOTES SCALE:1/8" = 1'-0"2 1-STORY 4-PLEX FIRST FLOORNORTH NORTH ORIENTATION VARIES - REFER TO CIVIL REF.WDDW REF. WD DW REF.WDDW REF. WD DW REF. WD DW 1' - 9" 6' - 0" 4' - 2" 6' - 0" 1' - 9"14' - 0"54' - 0"24' - 0" 6' - 0" 24' - 0" 14' - 0" 2' - 0" 16' - 0" 2' - 1"2' - 8" 16' - 0" 2' - 8" 6' - 8"2' - 2" 16' - 0" 3' - 2" 6' - 8" 2' - 8" 16' - 0" 2' - 8"6' - 8" 2' - 1" 16' - 0" 2' - 0" 5' - 7" 2' - 4" 6' - 0" 2' - 4"2' - 4" 6' - 0" 2' - 4" 5' - 7" 5' - 4" 6' - 0" 5' - 4" 19' - 8" 16' - 8" 19' - 8"28' - 0"28' - 0"28' - 0"19' - 8" 16' - 8"6' - 0"UNIT 101 TYPE 3A 1750 SF 1/4" PER FT, TYP1/4" PER FT, TYP1/4" PER FT, TYP3' - 0"20' - 0"1' - 9" 6' - 0"4' - 2"6' - 0"1' - 9" 5' - 4"6' - 0"5' - 4"19' - 8" 10" 5' - 0"9 1/2"6' - 0"UNIT 105 TYPE 3A 1750 SF UNIT 103 TYPE 2A 1631 SF 1/4" PER FT, TYP1/4" PER FT, TYP1/4" PER FT, TYP21' - 3" TYP DIMS 3' - 0"2' - 3"3' - 0"20' - 0"10' - 8" 5' - 7" 20' - 1"21' - 4" 6' - 8" 21' - 4" 6' - 8" 21' - 4" 6' - 8" 20' - 1" 5' - 7" 10' - 8" 35' - 4 1/8" 11 1/2" 27' - 0 1/2" 11 1/2" 27' - 0 1/2" 11 1/2" 27' - 0 1/2" 11 1/2" 35' - 4 1/8"68' - 0"4' - 6" 6' - 0" 7' - 0" 6' - 0" 4' - 6" 4' - 6" 6' - 0" 7' - 0" 6' - 0" 4' - 6" 4' - 6" 6' - 0" 7' - 0" 6' - 0" 4' - 6" 14' - 6" 13' - 6" 14' - 6" 13' - 6" 14' - 6" 13' - 6" 156' - 8"14' - 0"54' - 0"24' - 0" 6' - 0" 24' - 0" 14' - 0" UNIT 102 TYPE 2A 1634 SF UNIT 104 TYPE 2A 1631 SF 1/4" PER FT, TYP1/4" PER FT, TYP21' - 4" 36' - 4"28' - 0"28' - 0"28' - 0"36' - 4" Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.SAA C:\Users\spoole\Documents\21113 Converge NW, Waukee, IA_5-Plex One-Story Townhouse_spoolePMDSN.rvt12/2/2021 3:22:40 PMCONVERGE NWTOWNHOUSESWAUKEE, IA21113 A-102 5-PLEX 1-STORY FLOOR PLAN SP SCALE:1/8" = 1'-0"1 5-PLEX 1-STORY FLOOR PLAN 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL SITE INFO, FURNITURE, FIXTURES AND EQUIPMENT SHOWN SHOULD BE CONSIDERED CONCEPTUAL AND MAY HAVE BE PROVIDED FOR COORDINATION PURPOSES ONLY. REFER TO CIVIL, FIRE SUPPRESSION, PLUMBING, MECHANICAL, ELECTRICAL, COMMUNICATIONS, ELECTRONIC SAFETY & SECURITY DOCUMENTS &/OR CONSULTANTS FOR SPECIFIC DESIGN INFORMATION & REQUIREMENTS. 3. DIMENSIONS ARE TO FACE OF FINISH MATERIAL OR CENTER OF STRUCTURE UNLESS OTHERWISE SPECIFIED. 4. ALL CONDUITS, PIPES, WIRING, ROUGH-IN, ETC. SHOULD BE HELD AS TIGHT AS POSSIBLE TO THE ROOF OR FLOOR DECK OR SHOULD BE KEPT WITHIN INTERIOR WALL CAVITIES. NOTHING SHALL BE BELOW THE BOTTOM EDGE OF MAIN BUILDING FRAMES, NOTHING SHALL BE EXPOSED IN FINISHED SPACES, NOTHING SHALL PREVENT A SMOOTH CONTINUOUS FINISHED WALL OR CEILING AS NOTED ON THE DRAWINGS AND NO PLUMBING RAN IN EXTERIOR WALLS UNLESS PRIOR APPROVAL IS GRANTED BY THE ARCHITECT OR OWNER. PLACEMENT COORDINATION BETWEEN TRADES IS REQUIRED. 5. INSTALL VERTICAL EXPANSION JOINT MINIMAL AT COLUMN/GRID LINES AND AT THE HEAD OF DOOR JAMBS/OPENINGS OR AS OTHERWISE NOTED OR WHERE REQUIRED PER STANDARD MATERIAL PRACTICE TO REDUCE STRESS CRACKING. NO CONTROL JOINT/EXPANSION JOINT IN LOAD BEARING AREAS, STAY AWAY 2'-6" MIN. 6. CAULK & SEAL ALL CONTROL-EXPANSION, SAWCUT JOINTS AT ALL INTERIOR & EXTERIOR MASONRY & CONCRETE. 7. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM BUILDING WITHOUT PONDING OF WATER ADJACENT TO BUILDING OR ON PAVEMENTS. GENERAL FLOOR PLAN NOTES Rev. #Issue / RevisionDate330% Set12-03-2021NORTH REF.WDDW REF.WDDW REF. DW REF. DW WDWD10' - 8" 5' - 7" 20' - 1" 20' - 3 1/2" 6' - 3" 20' - 3 1/2" 20' - 1" 5' - 7" 10' - 8" 35' - 4 1/8" 11 1/2" 22' - 5 1/2" 11 1/2" 22' - 5 1/2" 11 1/2" 35' - 4 1/8"3' - 0"45' - 0"6' - 0"UNIT 101 TYPE 3A 1730 SF UNIT 102 TYPE 3B 975 SF 3' - 0"2' - 0" 16' - 0" 2' - 1" 2' - 2 1/2"16' - 0" 2' - 1"2' - 4" 6' - 0" 2' - 4" 2' - 1" 3' - 0" 6"24' - 0" 6' - 0" 24' - 0"54' - 0"16' - 8" 19' - 8"23' - 5"23' - 5" 3' - 2" 5' - 0" 6' - 3" 6' - 0" 3' - 0" 3' - 0" 6' - 0" 6' - 3" 5' - 0" 3' - 2"6' - 0"5' - 4" 6' - 0" 5' - 4" 1' - 9" 6' - 0" 4' - 2" 6' - 0" 1' - 9"1/4" PER FT, TYP1/4" PER FT, TYP6"3' - 0"21' - 6" TYP DIMS6' - 0"45' - 0"3' - 0"UNIT 103 TYPE 3B 975 SF UNIT 104 TYPE 3A 1730 SF 3' - 0"54' - 0"3' - 6"6' - 0"14' - 6"6' - 0"14' - 6"6' - 0"3' - 6"6" 3' - 0" 2' - 1" 2' - 4" 6' - 0" 2' - 4"2' - 1" 16' - 0" 2' - 2 1/2" 2' - 0" 16' - 0" 2' - 1"6' - 0"1' - 9" 6' - 0" 4' - 2" 6' - 0" 1' - 9" 5' - 4" 6' - 0" 5' - 4"10' - 0"1/4" PER FT, TYP1/4" PER FT, TYP1/4" PER FT, TYP13' - 5" 10' - 0" 10' - 0" 13' - 5" 36' - 4"23' - 5"23' - 5"36' - 4" 119' - 6" 19' - 8" 16' - 8" 6" / 12"6" / 12"5" / 12"5" / 12"5" / 12"5" / 12"UNIT 102 TYPE 3B 1053 SF UNIT 103 TYPE 3B 1053 SF1' - 6"54' - 0"1' - 6"57' - 11 1/8"1' - 0" 36' - 4"20' - 5" 6' - 0" 20' - 5"36' - 4" 1' - 0"6' - 0" 1' - 6" 3' - 5" 3' - 0" 7' - 8" 3' - 0" 3' - 4" 6' - 0" 3' - 4" 3' - 0" 7' - 8" 3' - 0" 3' - 5" 3' - 2" 5' - 0" 15' - 3" 15' - 3" 5' - 0" 3' - 2"1' - 6"6" / 12"6" / 12" ROOF SHEATHING WITHIN 4 FEET OF A DEMISING WALL IS 1/2" FIRE RATED PLYWOOD (HATCHED AREAS) - NO ROOF PENETRATIONS IN THIS AREA 7 1/2" 17' - 0 3/4" SEE SHEET A-113 FOR ROOF PLAN Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.SAA C:\Users\spoole\Documents\21113 Converge NW, Waukee, IA_4-Plex Two-Story Townhouse_spoolePMDSN.rvt12/2/2021 3:19:17 PMCONVERGE NWTOWNHOUSESWAUKEE, IA21113 A-103 4-PLEX 2-STORY FLOOR PLAN SP SCALE:1/8" = 1'-0"1 4-PLEX 2-STORY FIRST FLOOR SCALE:1/8" = 1'-0"2 4-PLEX 2-STORY SECOND FLOOR 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL SITE INFO, FURNITURE, FIXTURES AND EQUIPMENT SHOWN SHOULD BE CONSIDERED CONCEPTUAL AND MAY HAVE BE PROVIDED FOR COORDINATION PURPOSES ONLY. REFER TO CIVIL, FIRE SUPPRESSION, PLUMBING, MECHANICAL, ELECTRICAL, COMMUNICATIONS, ELECTRONIC SAFETY & SECURITY DOCUMENTS &/OR CONSULTANTS FOR SPECIFIC DESIGN INFORMATION & REQUIREMENTS. 3. DIMENSIONS ARE TO FACE OF FINISH MATERIAL OR CENTER OF STRUCTURE UNLESS OTHERWISE SPECIFIED. 4. ALL CONDUITS, PIPES, WIRING, ROUGH-IN, ETC. SHOULD BE HELD AS TIGHT AS POSSIBLE TO THE ROOF OR FLOOR DECK OR SHOULD BE KEPT WITHIN INTERIOR WALL CAVITIES. NOTHING SHALL BE BELOW THE BOTTOM EDGE OF MAIN BUILDING FRAMES, NOTHING SHALL BE EXPOSED IN FINISHED SPACES, NOTHING SHALL PREVENT A SMOOTH CONTINUOUS FINISHED WALL OR CEILING AS NOTED ON THE DRAWINGS AND NO PLUMBING RAN IN EXTERIOR WALLS UNLESS PRIOR APPROVAL IS GRANTED BY THE ARCHITECT OR OWNER. PLACEMENT COORDINATION BETWEEN TRADES IS REQUIRED. 5. INSTALL VERTICAL EXPANSION JOINT MINIMAL AT COLUMN/GRID LINES AND AT THE HEAD OF DOOR JAMBS/OPENINGS OR AS OTHERWISE NOTED OR WHERE REQUIRED PER STANDARD MATERIAL PRACTICE TO REDUCE STRESS CRACKING. NO CONTROL JOINT/EXPANSION JOINT IN LOAD BEARING AREAS, STAY AWAY 2'-6" MIN. 6. CAULK & SEAL ALL CONTROL-EXPANSION, SAWCUT JOINTS AT ALL INTERIOR & EXTERIOR MASONRY & CONCRETE. 7. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM BUILDING WITHOUT PONDING OF WATER ADJACENT TO BUILDING OR ON PAVEMENTS. GENERAL FLOOR PLAN NOTES Rev. #Issue / RevisionDate330% Set12-03-2021NORTH ORIENTATION VARIES - REFER TO CIVIL NORTH ORIENTATION VARIES - REFER TO CIVIL A-201 5 A-2016 ROOF SHEATHING WITHIN 4 FEET OF A DEMISING WALL IS 1/2" FIRE RATED PLYWOOD (HATCHED AREAS) - NO ROOF PENETRATIONS IN THIS AREA ROOF VENT, TYP. ROOF VENT, TYP 5" / 12"5" / 12"DS (DOWNSPOUT)DS DSDSDS A-201 3 A-201 4 ROOF SHEATHING WITHIN 4 FEET OF A DEMISING WALL IS 1/2" FIRE RATED PLYWOOD (HATCHED AREAS) - NO ROOF PENETRATIONS IN THIS AREA ROOF VENT, TYP. ROOF VENT, TYP DS (DOWNSPOUT)DS Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.SAA C:\Users\spoole\Documents\21113 Converge NW, Waukee, IA_3&4-Plex One-Story Townhouse_spoolePMDSN.rvt12/2/2021 3:26:23 PMCONVERGE NWTOWNHOUSESWAUKEE, IOWA21113 A-111 3/4-PLEX 1-STORY ROOF PLAN SP 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL FIXTURES AND EQUIPMENT SHOWN SHOULD BE CONSIDERED CONCEPTUAL AND MAY BE PROVIDED FOR COORDINATION PURPOSES ONLY. REFER TO CIVIL, FIRE SUPPRESSION, PLUMBING, MECHANICAL, ELECTRICAL, COMMUNICATIONS, ELECTRONIC SAFETY & SECURITY DOCUMENTS &/OR CONSULTANTS FOR SPECIFIC DESIGN INFORMATION & REQUIREMENTS. REFER TO STRUCTURAL DRAWINGS FOR ROOF OPENING STRUCTURAL FRAMING. 3. ALL ROOF PENETRATIONS FOR MINOR ROOF VENTS AND SIMILAR ITEMS MAY NOT BE INDICATED ON THE ROOF PLAN: HOWEVER, ALL ROOF FLASHING WORK SHALL BE PROVIDED BY THE ROOFING SUBCONTRACTOR SO AS TO OBTAIN FULL ROOFING WARRANTIES. REFER TO ALL OTHER CONSTRUCTION DOCUMENTS FOR ADDITIONAL ROOF PENETRATIONS REQUIRING ROOF FLASHING WORK. 4. IT SHOULD BE THE RESPONSIBILITY OF THE ROOF SUB-CONTRACTOR TO PROVIDE ALL NECESSARY DETAILS AND SYSTEMS TO ACCOMMODATE EXPANSION/CONTRACTION OF THE BUILDING AND BUILDING COMPONENTS FOR A LONG-LASTING ROOF. 5. CONTRACTOR SHALL KEEP ROOF CLEAN OF ALL DEBRIS DURING ALL CONSTRUCTION WORK. 6. ROOF SYSTEM AND ANY WORK ASSOCIATED WITH THE ROOF SHALL BE DONE AS TO NOT VOID ANY ROOF WARRANTIES. 7. FLASHING: A. FLASHING SHALL BE INSTALLED IN SUCH A MANNER SO AS TO PREVENT MOISTURE ENTERING THE WALL AND ROOF THROUGH JOINTS IN COPINGS & AT INTERSECTIONS WITH PARAPET WALLS & OTHER PENETRATIONS THROUGH THE ROOF PLANE. B. FLASHING SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, AT GUTTERS, WHEREVER THERE IS A CHANGE IN ROOF SLOPE OR DIRECTION AND AROUND ROOF OPENINGS. WHERE FLASHING IS METAL, THE METAL SHALL BE CORROSION RESISTANT WITH A THICKNESS OF NOT LESS THAN 0.019”, NO. 26 GALVANIZED SHEET. 8. ROOF DRAINAGE: A. DESIGN OF ROOF DRAINAGE SYSTEMS SHALL COMPLY WITH THE INT'L PLUMBING CODE. FINAL DETAILED DESIGN OF ROOF DRAINAGE SYSTEMS TO BE BY PLUMBING CONSULTANT. B. OVERSIZED ROOF DRAINS, GUTTERS AND/OR DOWNSPOUTS SHOULD BE PROVIDED TO ELIMINATE ANY OVERFLOW OR BACKUP. C. PROVIDE CONCRETE SPLASH BLOCKS AT ALL DOWNSPOUT LOCATIONS. 9. ROOF VENTILATION INTAKE & EXHAUST VENTS SHALL BE PROVIDED IN EACH & ALL ENCLOSED ATTICS &/OR RAFTER SPACES TO CREATE CROSS VENTILATION IN ACCORDANCE WITH CODES & THE MANUFACTURES INSTALLATION INSTRUCTIONS. 10. INSULATE AND SEAL TO ENSURE ADEQUATE AIR INFILTRATION BARRIER AROUND ALL EXTERIOR PENETRATIONS TO PREVENT WATER AND SPRINKLER PIPE FREEZING. 11. ACCESS TO UNOCCUPIED SPACES A. CRAWL SPACES SHALL BE PROVIDED WITH NO FEWER THAN 1 ACCESS OPENING WHICH SHALL NOT BE LESS THAN 18" X 24". B. AN OPENING OF NOT LESS THAN 20"X30" SHALL BE PROVIDED TO ANY ATTIC AREA HAVING A CLEAR HEIGHT OF OVER 30". CLEAR HEADROOM OF NOT LESS THAN 30" SHALL BE PROVIDED IN THE ATTIC SPACE AT OR ABOVE THE ACCESS OPENING. C. ACCESS TO MECHANICAL APPLIANCES INSTALLED IN UNDER FLOOR AREAS, IN ATTIC SPACES AND ON ROOFS OR ELEVATED STRUCTURES SHALL BE IN ACCORDANCE WITH THE INT'L MECHANICAL CODE. a. ATTICS CONTAINING APPLIANCES SHALL BE PROVIDED WITH AN OPENING AND UNOBSTRUCTED PASSAGEWAY LARGE ENOUGH TO ALLOW REMOVAL OF THE LARGEST APPLIANCE. THE PASSAGEWAY SHALL NOT BE LESS THAN 30”H X 22”W AND NOT MORE THAN 20’IN LENGTH MEASURED ALONG THE CENTERLINE OF THE PASSAGEWAY FROM THE OPENING TO THE APPLIANCE. THE PASSAGEWAY SHALL HAVE CONTINUOUS SOLD FLOORING NOT LESS THAN 24”WIDE. A LEVEL SURFACE SPACE NOT LESS THAN 30”D X 30”W SHALL BE PRESENT AT THE FRONT OF SERVICE SIDE OF THE APPLIANCE. 12. ROOF TRUSSES DESIGN BUILD BY TRUSS MANUFACTURER. 13. ASPHALT SHINGLES: A. ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF SLOPES OF 2:12 OR GREATER. B. FOR ROOF SLOPES FROM 2:12 (17%) & UP TO 4:12 (33%), UNDERLAYMENT SHALL BE 2 LAYERS APPLIED IN THE FOLLOWING MANNER. APPLY A MINIMUM 19”WIDE STRIP OF UNDERLAYMENT FELT PARALLEL WITH & STARTING AT THE EAVES, FASTENED SUFFICIENTLY TO HOLD IN PLACE. STARTING AT THE EAVE, APPLY 36”WIDE SHEETS OF UNDERLAYMENT OVERLAPPING SUCCESSIVE SHEETS 19”, BY FASTENED SUFFICIENTLY TO HOLD IN PLACE. C. FOR ROOF SLOPES OF 4:12 (33%) OR GREATER, UNDERLAYMENT SHALL BE ONE LAYER APPLIED IN THE FOLLOWING MANNER. UNDERLAYMENT SHALL BE APPLIED SHINGLE FASHION, PARALLEL TO & STARTING FROM THE EAVE & LAPPED 2”, FASTENED SUFFICIENTLY TO HOLD IN PLACE. D. AN ICE BARRIER THAT CONSISTS OF AT LEAST TWO LAYER OF UNDERLAYMENT CEMENTED TOGETHER OR OF A SELF-ADHERING POLYMER MODIFIED BITUMEN SHEET SHALL BE USED IN LIEU OF NORMAL UNDERLAYMENT AND EXTEND FROM THE LOWEST EDGES OF ALL ROOF SURFACES TO A POINT AT LEAST 24" INSIDE THE EXTERIOR WALL LINE OF THE BUILDING. GENERAL ROOF PLAN NOTES DRAFTSTOPPING ONLY REQUIRED IN COMBUSTIBLE BUILDINGS WITHOUT AUTOMATIC SPRINKLER SYSTEMS THROUGHOUT. 1. DRAFTSTOPPING IN FLOORS SHALL BE INSTALLED TO SUBDIVIDE FLOOR/CEILING ASSEMBLIES: A. GROUPS ALL R-1; R-2 WITH 3 OR MORE DWELLING UNITS; R-3 WITH 2 DWELLING UNITS; & ALL R-4 BUILDINGS – SHALL BE LOCATED ABOVE & IN-LINE WITH THE DWELLING UNIT AND SLEEPING UNIT SEPARATIONS. B. ALL OTHER GROUPS – SHALL BE INSTALLED SO THAT HORIZONTAL FLOOR AREAS DO NOT EXCEED 1,000 SF. 2. DRAFTSTOPPING IN ATTICS SHALL BE INSTALLED TO SUBDIVIDE ATTIC SPACES & CONCEALED ROOF SPACES: A. GROUPS ALL R-1; & R-2 WITH 3 OR MORE DWELLING UNITS – SHALL BE LOCATED ABOVE & IN-LINE WITH THE SLEEPING UNIT & DWELLING UNIT SEPARATION WALLS THAT DO NOT EXTEND TO THE UNDERSIDE OF THE ROOF SHEATHING ABOVE. B. EXCEPTION 1: WHERE CORRIDOR WALLS PROVIDE A SEPARATION, ONLY REQUIRED ABOVE ONE OF THE CORRIDOR WALLS. C. EXCEPTION 3: R-2 THAT DO NOT EXCEED 4 STORIES ABOVE GRADE PLANE, THE ATTIC SPACE SHALL BE SUBDIVIDED INTO AREAS NOT EXCEEDING 3,000 SF OR ABOVE EVERY 2 DWELLING UNITS, WHICHEVER IS SMALLER. D. ALL OTHER GROUPS - SHALL BE INSTALLED SUCH THAT ANY HORIZONTAL AREA DOES NOT EXCEED 3,000 SF. 3. DRAFTSTOPPING MATERIALS SHALL BE NO LESS THAN 1/2" GYP BD, 3/8" WOOD STRUCTURAL PANEL, OR 3/8" PARTICLEBOARD, 1" NOMINAL LUMBER, CEMENT FIBERBOARD, BATTS OR BLANKETS OF MINERAL WOOL OR GLASS FIBER, ADEQUATELY SUPPORTED. 4. OPENINGS IN THE DRAFTSTOPPING SHALL BE PROTECTED BY SELF-CLOSING DOORS W/ AUTOMATIC LATCHES CONSTRUCTED AS REQUIRED FOR THE DRAFTSTOPPING PARTITIONS. GENERAL DRAFTSTOPPING: 1. PENETRATIONS INTO OR THROUGH FIRE-RESISTIVE-RATED WALL ASSEMBLIES AND HORIZONTAL ASSEMBLIES SHALL BE PROTECTED BY APPROVED PENETRATION FIRESTOP SYSTEMS DESIGNED TO RESIST THE PASSAGE OF FIRE FOR A TIME PERIOD NOT LESS THAN THE REQUIRED FIRE-RESISTANCE RATING WHICH IT IS INSTALLED. 2. ALL JOINTS INSTALLED IN OR BETWEEN FIRE-RESISTIVE-RATED WALLS, FLOORS OR FLOOR/CEILING ASSEMBLIES AND ROOFS OR ROOF/CEILING ASSEMBLIES SHALL BE PROTECTED BY APPROVED FIRE-RESISTANT JOINT SYSTEM DESIGNED TO RESIST THE PASSAGE OF FIRE FOR A TIME PERIOD NOT LESS THAN THE REQUIRED FIRE-RESISTANCE RATING WHICH IT IS INSTALLED. (IBC 2012 Sec. 715) GENERAL FIRESTOPPING & JOINT NOTES: SCALE:1/8" = 1'-0"1 3-PLEX 1-STORY ROOF PLAN Rev. #Issue / RevisionDate330% Set12-03-2021SCALE:1/8" = 1'-0"2 4-PLEX 1-STORY ROOF PLANNORTH NORTH ORIENTATION VARIES - REFER TO CIVIL 6" / 12"6" / 12" ROOF SHEATHING WITHIN 4 FEET OF A DEMISING WALL IS 1/2" FIRE RATED PLYWOOD (HATCHED AREAS) - NO ROOF PENETRATIONS IN THIS AREA END UNITS REQUIRE A MIN. OF 423 SQ. IN. OF NET FREE AREA FOR ATTIC VENTILATION AT RIDGE AND AT SOFFITS EACH MIDDLE UNIT REQUIRE A MIN. OF 444 SQ. IN. OF NET FREE AREA FOR ATTIC VENTILATION AT RIDGE AND AT SOFFITS 6" / 12"6" / 12" 6" / 12"6" / 12" ROOF VENT, TYP RC RC DS DS (DOWNSPOUT)DSDS DS DSDSDSDSDS RC DS Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.SAA C:\Users\spoole\Documents\21113 Converge NW, Waukee, IA_5-Plex One-Story Townhouse_spoolePMDSN.rvt12/2/2021 3:22:40 PMCONVERGE NWTOWNHOUSESWAUKEE, IA21113 A-112 5-PLEX 1-STORY ROOF PLAN SP 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL FIXTURES AND EQUIPMENT SHOWN SHOULD BE CONSIDERED CONCEPTUAL AND MAY BE PROVIDED FOR COORDINATION PURPOSES ONLY. REFER TO CIVIL, FIRE SUPPRESSION, PLUMBING, MECHANICAL, ELECTRICAL, COMMUNICATIONS, ELECTRONIC SAFETY & SECURITY DOCUMENTS &/OR CONSULTANTS FOR SPECIFIC DESIGN INFORMATION & REQUIREMENTS. REFER TO STRUCTURAL DRAWINGS FOR ROOF OPENING STRUCTURAL FRAMING. 3. ALL ROOF PENETRATIONS FOR MINOR ROOF VENTS AND SIMILAR ITEMS MAY NOT BE INDICATED ON THE ROOF PLAN: HOWEVER, ALL ROOF FLASHING WORK SHALL BE PROVIDED BY THE ROOFING SUBCONTRACTOR SO AS TO OBTAIN FULL ROOFING WARRANTIES. REFER TO ALL OTHER CONSTRUCTION DOCUMENTS FOR ADDITIONAL ROOF PENETRATIONS REQUIRING ROOF FLASHING WORK. 4. IT SHOULD BE THE RESPONSIBILITY OF THE ROOF SUB-CONTRACTOR TO PROVIDE ALL NECESSARY DETAILS AND SYSTEMS TO ACCOMMODATE EXPANSION/CONTRACTION OF THE BUILDING AND BUILDING COMPONENTS FOR A LONG-LASTING ROOF. 5. CONTRACTOR SHALL KEEP ROOF CLEAN OF ALL DEBRIS DURING ALL CONSTRUCTION WORK. 6. ROOF SYSTEM AND ANY WORK ASSOCIATED WITH THE ROOF SHALL BE DONE AS TO NOT VOID ANY ROOF WARRANTIES. 7. FLASHING: A. FLASHING SHALL BE INSTALLED IN SUCH A MANNER SO AS TO PREVENT MOISTURE ENTERING THE WALL AND ROOF THROUGH JOINTS IN COPINGS & AT INTERSECTIONS WITH PARAPET WALLS & OTHER PENETRATIONS THROUGH THE ROOF PLANE. B. FLASHING SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, AT GUTTERS, WHEREVER THERE IS A CHANGE IN ROOF SLOPE OR DIRECTION AND AROUND ROOF OPENINGS. WHERE FLASHING IS METAL, THE METAL SHALL BE CORROSION RESISTANT WITH A THICKNESS OF NOT LESS THAN 0.019”, NO. 26 GALVANIZED SHEET. 8. ROOF DRAINAGE: A. DESIGN OF ROOF DRAINAGE SYSTEMS SHALL COMPLY WITH THE INT'L PLUMBING CODE. FINAL DETAILED DESIGN OF ROOF DRAINAGE SYSTEMS TO BE BY PLUMBING CONSULTANT. B. OVERSIZED ROOF DRAINS, GUTTERS AND/OR DOWNSPOUTS SHOULD BE PROVIDED TO ELIMINATE ANY OVERFLOW OR BACKUP. C. PROVIDE CONCRETE SPLASH BLOCKS AT ALL DOWNSPOUT LOCATIONS. 9. ROOF VENTILATION INTAKE & EXHAUST VENTS SHALL BE PROVIDED IN EACH & ALL ENCLOSED ATTICS &/OR RAFTER SPACES TO CREATE CROSS VENTILATION IN ACCORDANCE WITH CODES & THE MANUFACTURES INSTALLATION INSTRUCTIONS. GENERAL ROOF PLAN NOTES 9. INSULATE AND SEAL TO ENSURE ADEQUATE AIR INFILTRATION BARRIER AROUND ALL EXTERIOR PENETRATIONS TO PREVENT WATER AND SPRINKLER PIPE FREEZING. 10. ACCESS TO UNOCCUPIED SPACES A. CRAWL SPACES SHALL BE PROVIDED WITH NO FEWER THAN 1 ACCESS OPENING WHICH SHALL NOT BE LESS THAN 18" X 24". B. AN OPENING OF NOT LESS THAN 20"X30" SHALL BE PROVIDED TO ANY ATTIC AREA HAVING A CLEAR HEIGHT OF OVER 30". CLEAR HEADROOM OF NOT LESS THAN 30" SHALL BE PROVIDED IN THE ATTIC SPACE AT OR ABOVE THE ACCESS OPENING. C. ACCESS TO MECHANICAL APPLIANCES INSTALLED IN UNDER FLOOR AREAS, IN ATTIC SPACES AND ON ROOFS OR ELEVATED STRUCTURES SHALL BE IN ACCORDANCE WITH THE INT'L MECHANICAL CODE. a. ATTICS CONTAINING APPLIANCES SHALL BE PROVIDED WITH AN OPENING AND UNOBSTRUCTED PASSAGEWAY LARGE ENOUGH TO ALLOW REMOVAL OF THE LARGEST APPLIANCE. THE PASSAGEWAY SHALL NOT BE LESS THAN 30”H X 22”W AND NOT MORE THAN 20’IN LENGTH MEASURED ALONG THE CENTERLINE OF THE PASSAGEWAY FROM THE OPENING TO THE APPLIANCE. THE PASSAGEWAY SHALL HAVE CONTINUOUS SOLD FLOORING NOT LESS THAN 24”WIDE. A LEVEL SURFACE SPACE NOT LESS THAN 30”D X 30”W SHALL BE PRESENT AT THE FRONT OF SERVICE SIDE OF THE APPLIANCE. 11. ROOF TRUSSES DESIGN BUILD BY TRUSS MANUFACTURER. 12. ASPHALT SHINGLES: A. ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF SLOPES OF 2:12 OR GREATER. B. FOR ROOF SLOPES FROM 2:12 (17%) & UP TO 4:12 (33%), UNDERLAYMENT SHALL BE 2 LAYERS APPLIED IN THE FOLLOWING MANNER. APPLY A MINIMUM 19”WIDE STRIP OF UNDERLAYMENT FELT PARALLEL WITH & STARTING AT THE EAVES, FASTENED SUFFICIENTLY TO HOLD IN PLACE. STARTING AT THE EAVE, APPLY 36”WIDE SHEETS OF UNDERLAYMENT OVERLAPPING SUCCESSIVE SHEETS 19”, BY FASTENED SUFFICIENTLY TO HOLD IN PLACE. C. FOR ROOF SLOPES OF 4:12 (33%) OR GREATER, UNDERLAYMENT SHALL BE ONE LAYER APPLIED IN THE FOLLOWING MANNER. UNDERLAYMENT SHALL BE APPLIED SHINGLE FASHION, PARALLEL TO & STARTING FROM THE EAVE & LAPPED 2”, FASTENED SUFFICIENTLY TO HOLD IN PLACE. D. AN ICE BARRIER THAT CONSISTS OF AT LEAST TWO LAYER OF UNDERLAYMENT CEMENTED TOGETHER OR OF A SELF-ADHERING POLYMER MODIFIED BITUMEN SHEET SHALL BE USED IN LIEU OF NORMAL UNDERLAYMENT AND EXTEND FROM THE LOWEST EDGES OF ALL ROOF SURFACES TO A POINT AT LEAST 24" INSIDE THE EXTERIOR WALL LINE OF THE BUILDING. DRAFTSTOPPING ONLY REQUIRED IN COMBUSTIBLE BUILDINGS WITHOUT AUTOMATIC SPRINKLER SYSTEMS THROUGHOUT. 1. DRAFTSTOPPING IN FLOORS SHALL BE INSTALLED TO SUBDIVIDE FLOOR/CEILING ASSEMBLIES: A. GROUPS ALL R-1; R-2 WITH 3 OR MORE DWELLING UNITS; R-3 WITH 2 DWELLING UNITS; & ALL R-4 BUILDINGS – SHALL BE LOCATED ABOVE & IN-LINE WITH THE DWELLING UNIT AND SLEEPING UNIT SEPARATIONS. B. ALL OTHER GROUPS – SHALL BE INSTALLED SO THAT HORIZONTAL FLOOR AREAS DO NOT EXCEED 1,000 SF. 2. DRAFTSTOPPING IN ATTICS SHALL BE INSTALLED TO SUBDIVIDE ATTIC SPACES & CONCEALED ROOF SPACES: A. GROUPS ALL R-1; & R-2 WITH 3 OR MORE DWELLING UNITS – SHALL BE LOCATED ABOVE & IN-LINE WITH THE SLEEPING UNIT & DWELLING UNIT SEPARATION WALLS THAT DO NOT EXTEND TO THE UNDERSIDE OF THE ROOF SHEATHING ABOVE. B. EXCEPTION 1: WHERE CORRIDOR WALLS PROVIDE A SEPARATION, ONLY REQUIRED ABOVE ONE OF THE CORRIDOR WALLS. C. EXCEPTION 3: R-2 THAT DO NOT EXCEED 4 STORIES ABOVE GRADE PLANE, THE ATTIC SPACE SHALL BE SUBDIVIDED INTO AREAS NOT EXCEEDING 3,000 SF OR ABOVE EVERY 2 DWELLING UNITS, WHICHEVER IS SMALLER. D. ALL OTHER GROUPS - SHALL BE INSTALLED SUCH THAT ANY HORIZONTAL AREA DOES NOT EXCEED 3,000 SF. 3. DRAFTSTOPPING MATERIALS SHALL BE NO LESS THAN 1/2" GYP BD, 3/8" WOOD STRUCTURAL PANEL, OR 3/8" PARTICLEBOARD, 1" NOMINAL LUMBER, CEMENT FIBERBOARD, BATTS OR BLANKETS OF MINERAL WOOL OR GLASS FIBER, ADEQUATELY SUPPORTED. 4. OPENINGS IN THE DRAFTSTOPPING SHALL BE PROTECTED BY SELF-CLOSING DOORS W/ AUTOMATIC LATCHES CONSTRUCTED AS REQUIRED FOR THE DRAFTSTOPPING PARTITIONS. GENERAL DRAFTSTOPPING: 1. PENETRATIONS INTO OR THROUGH FIRE-RESISTIVE-RATED WALL ASSEMBLIES AND HORIZONTAL ASSEMBLIES SHALL BE PROTECTED BY APPROVED PENETRATION FIRESTOP SYSTEMS DESIGNED TO RESIST THE PASSAGE OF FIRE FOR A TIME PERIOD NOT LESS THAN THE REQUIRED FIRE-RESISTANCE RATING WHICH IT IS INSTALLED. 2. ALL JOINTS INSTALLED IN OR BETWEEN FIRE-RESISTIVE-RATED WALLS, FLOORS OR FLOOR/CEILING ASSEMBLIES AND ROOFS OR ROOF/CEILING ASSEMBLIES SHALL BE PROTECTED BY APPROVED FIRE-RESISTANT JOINT SYSTEM DESIGNED TO RESIST THE PASSAGE OF FIRE FOR A TIME PERIOD NOT LESS THAN THE REQUIRED FIRE-RESISTANCE RATING WHICH IT IS INSTALLED. (IBC 2012 Sec. 715) GENERAL FIRESTOPPING & JOINT NOTES: SCALE:1/8" = 1'-0"1 5-PLEX 1-STORY ROOF PLAN Rev. #Issue / RevisionDate330% Set12-03-2021NORTH 1 A-302 3 A-302 6" / 12"6" / 12"6" / 12" ROOF SHEATHING WITHIN 4 FEET OF A DEMISING WALL IS 1/2" FIRE RATED PLYWOOD (HATCHED AREAS) - NO ROOF PENETRATIONS IN THIS AREA 5" / 12"5" / 12"6" / 12"6" / 12"6" / 12"6" / 12"5" / 12"5" / 12"6" / 12"ROOF VENT, TYP ROOF VENT, TYP DS DSDSDSDS DS DS (DOWNSPOUT) DS DS (DOWNSPOUT) DS Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.SAA C:\Users\spoole\Documents\21113 Converge NW, Waukee, IA_4-Plex Two-Story Townhouse_spoolePMDSN.rvt12/2/2021 3:19:17 PMCONVERGE NWTOWNHOUSESWAUKEE, IA21113 A-113 4-PLEX 2-STORY ROOF PLAN SP 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL FIXTURES AND EQUIPMENT SHOWN SHOULD BE CONSIDERED CONCEPTUAL AND MAY BE PROVIDED FOR COORDINATION PURPOSES ONLY. REFER TO CIVIL, FIRE SUPPRESSION, PLUMBING, MECHANICAL, ELECTRICAL, COMMUNICATIONS, ELECTRONIC SAFETY & SECURITY DOCUMENTS &/OR CONSULTANTS FOR SPECIFIC DESIGN INFORMATION & REQUIREMENTS. REFER TO STRUCTURAL DRAWINGS FOR ROOF OPENING STRUCTURAL FRAMING. 3. ALL ROOF PENETRATIONS FOR MINOR ROOF VENTS AND SIMILAR ITEMS MAY NOT BE INDICATED ON THE ROOF PLAN: HOWEVER, ALL ROOF FLASHING WORK SHALL BE PROVIDED BY THE ROOFING SUBCONTRACTOR SO AS TO OBTAIN FULL ROOFING WARRANTIES. REFER TO ALL OTHER CONSTRUCTION DOCUMENTS FOR ADDITIONAL ROOF PENETRATIONS REQUIRING ROOF FLASHING WORK. 4. IT SHOULD BE THE RESPONSIBILITY OF THE ROOF SUB-CONTRACTOR TO PROVIDE ALL NECESSARY DETAILS AND SYSTEMS TO ACCOMMODATE EXPANSION/CONTRACTION OF THE BUILDING AND BUILDING COMPONENTS FOR A LONG-LASTING ROOF. 5. CONTRACTOR SHALL KEEP ROOF CLEAN OF ALL DEBRIS DURING ALL CONSTRUCTION WORK. 6. ROOF SYSTEM AND ANY WORK ASSOCIATED WITH THE ROOF SHALL BE DONE AS TO NOT VOID ANY ROOF WARRANTIES. 7. FLASHING: A. FLASHING SHALL BE INSTALLED IN SUCH A MANNER SO AS TO PREVENT MOISTURE ENTERING THE WALL AND ROOF THROUGH JOINTS IN COPINGS & AT INTERSECTIONS WITH PARAPET WALLS & OTHER PENETRATIONS THROUGH THE ROOF PLANE. B. FLASHING SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, AT GUTTERS, WHEREVER THERE IS A CHANGE IN ROOF SLOPE OR DIRECTION AND AROUND ROOF OPENINGS. WHERE FLASHING IS METAL, THE METAL SHALL BE CORROSION RESISTANT WITH A THICKNESS OF NOT LESS THAN 0.019”, NO. 26 GALVANIZED SHEET. 8. ROOF DRAINAGE: A. DESIGN OF ROOF DRAINAGE SYSTEMS SHALL COMPLY WITH THE INT'L PLUMBING CODE. FINAL DETAILED DESIGN OF ROOF DRAINAGE SYSTEMS TO BE BY PLUMBING CONSULTANT. B. OVERSIZED ROOF DRAINS, GUTTERS AND/OR DOWNSPOUTS SHOULD BE PROVIDED TO ELIMINATE ANY OVERFLOW OR BACKUP. C. PROVIDE CONCRETE SPLASH BLOCKS AT ALL DOWNSPOUT LOCATIONS. 9. ROOF VENTILATION INTAKE & EXHAUST VENTS SHALL BE PROVIDED IN EACH & ALL ENCLOSED ATTICS &/OR RAFTER SPACES TO CREATE CROSS VENTILATION IN ACCORDANCE WITH CODES & THE MANUFACTURES INSTALLATION INSTRUCTIONS. GENERAL ROOF PLAN NOTES 9. INSULATE AND SEAL TO ENSURE ADEQUATE AIR INFILTRATION BARRIER AROUND ALL EXTERIOR PENETRATIONS TO PREVENT WATER AND SPRINKLER PIPE FREEZING. 10. ACCESS TO UNOCCUPIED SPACES A. CRAWL SPACES SHALL BE PROVIDED WITH NO FEWER THAN 1 ACCESS OPENING WHICH SHALL NOT BE LESS THAN 18" X 24". B. AN OPENING OF NOT LESS THAN 20"X30" SHALL BE PROVIDED TO ANY ATTIC AREA HAVING A CLEAR HEIGHT OF OVER 30". CLEAR HEADROOM OF NOT LESS THAN 30" SHALL BE PROVIDED IN THE ATTIC SPACE AT OR ABOVE THE ACCESS OPENING. C. ACCESS TO MECHANICAL APPLIANCES INSTALLED IN UNDER FLOOR AREAS, IN ATTIC SPACES AND ON ROOFS OR ELEVATED STRUCTURES SHALL BE IN ACCORDANCE WITH THE INT'L MECHANICAL CODE. a. ATTICS CONTAINING APPLIANCES SHALL BE PROVIDED WITH AN OPENING AND UNOBSTRUCTED PASSAGEWAY LARGE ENOUGH TO ALLOW REMOVAL OF THE LARGEST APPLIANCE. THE PASSAGEWAY SHALL NOT BE LESS THAN 30”H X 22”W AND NOT MORE THAN 20’IN LENGTH MEASURED ALONG THE CENTERLINE OF THE PASSAGEWAY FROM THE OPENING TO THE APPLIANCE. THE PASSAGEWAY SHALL HAVE CONTINUOUS SOLD FLOORING NOT LESS THAN 24”WIDE. A LEVEL SURFACE SPACE NOT LESS THAN 30”D X 30”W SHALL BE PRESENT AT THE FRONT OF SERVICE SIDE OF THE APPLIANCE. 11. ROOF TRUSSES DESIGN BUILD BY TRUSS MANUFACTURER. 12. ASPHALT SHINGLES: A. ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF SLOPES OF 2:12 OR GREATER. B. FOR ROOF SLOPES FROM 2:12 (17%) & UP TO 4:12 (33%), UNDERLAYMENT SHALL BE 2 LAYERS APPLIED IN THE FOLLOWING MANNER. APPLY A MINIMUM 19”WIDE STRIP OF UNDERLAYMENT FELT PARALLEL WITH & STARTING AT THE EAVES, FASTENED SUFFICIENTLY TO HOLD IN PLACE. STARTING AT THE EAVE, APPLY 36”WIDE SHEETS OF UNDERLAYMENT OVERLAPPING SUCCESSIVE SHEETS 19”, BY FASTENED SUFFICIENTLY TO HOLD IN PLACE. C. FOR ROOF SLOPES OF 4:12 (33%) OR GREATER, UNDERLAYMENT SHALL BE ONE LAYER APPLIED IN THE FOLLOWING MANNER. UNDERLAYMENT SHALL BE APPLIED SHINGLE FASHION, PARALLEL TO & STARTING FROM THE EAVE & LAPPED 2”, FASTENED SUFFICIENTLY TO HOLD IN PLACE. D. AN ICE BARRIER THAT CONSISTS OF AT LEAST TWO LAYER OF UNDERLAYMENT CEMENTED TOGETHER OR OF A SELF-ADHERING POLYMER MODIFIED BITUMEN SHEET SHALL BE USED IN LIEU OF NORMAL UNDERLAYMENT AND EXTEND FROM THE LOWEST EDGES OF ALL ROOF SURFACES TO A POINT AT LEAST 24" INSIDE THE EXTERIOR WALL LINE OF THE BUILDING. DRAFTSTOPPING ONLY REQUIRED IN COMBUSTIBLE BUILDINGS WITHOUT AUTOMATIC SPRINKLER SYSTEMS THROUGHOUT. 1. DRAFTSTOPPING IN FLOORS SHALL BE INSTALLED TO SUBDIVIDE FLOOR/CEILING ASSEMBLIES: A. GROUPS ALL R-1; R-2 WITH 3 OR MORE DWELLING UNITS; R-3 WITH 2 DWELLING UNITS; & ALL R-4 BUILDINGS – SHALL BE LOCATED ABOVE & IN-LINE WITH THE DWELLING UNIT AND SLEEPING UNIT SEPARATIONS. B. ALL OTHER GROUPS – SHALL BE INSTALLED SO THAT HORIZONTAL FLOOR AREAS DO NOT EXCEED 1,000 SF. 2. DRAFTSTOPPING IN ATTICS SHALL BE INSTALLED TO SUBDIVIDE ATTIC SPACES & CONCEALED ROOF SPACES: A. GROUPS ALL R-1; & R-2 WITH 3 OR MORE DWELLING UNITS – SHALL BE LOCATED ABOVE & IN-LINE WITH THE SLEEPING UNIT & DWELLING UNIT SEPARATION WALLS THAT DO NOT EXTEND TO THE UNDERSIDE OF THE ROOF SHEATHING ABOVE. B. EXCEPTION 1: WHERE CORRIDOR WALLS PROVIDE A SEPARATION, ONLY REQUIRED ABOVE ONE OF THE CORRIDOR WALLS. C. EXCEPTION 3: R-2 THAT DO NOT EXCEED 4 STORIES ABOVE GRADE PLANE, THE ATTIC SPACE SHALL BE SUBDIVIDED INTO AREAS NOT EXCEEDING 3,000 SF OR ABOVE EVERY 2 DWELLING UNITS, WHICHEVER IS SMALLER. D. ALL OTHER GROUPS - SHALL BE INSTALLED SUCH THAT ANY HORIZONTAL AREA DOES NOT EXCEED 3,000 SF. 3. DRAFTSTOPPING MATERIALS SHALL BE NO LESS THAN 1/2" GYP BD, 3/8" WOOD STRUCTURAL PANEL, OR 3/8" PARTICLEBOARD, 1" NOMINAL LUMBER, CEMENT FIBERBOARD, BATTS OR BLANKETS OF MINERAL WOOL OR GLASS FIBER, ADEQUATELY SUPPORTED. 4. OPENINGS IN THE DRAFTSTOPPING SHALL BE PROTECTED BY SELF-CLOSING DOORS W/ AUTOMATIC LATCHES CONSTRUCTED AS REQUIRED FOR THE DRAFTSTOPPING PARTITIONS. GENERAL DRAFTSTOPPING: 1. PENETRATIONS INTO OR THROUGH FIRE-RESISTIVE-RATED WALL ASSEMBLIES AND HORIZONTAL ASSEMBLIES SHALL BE PROTECTED BY APPROVED PENETRATION FIRESTOP SYSTEMS DESIGNED TO RESIST THE PASSAGE OF FIRE FOR A TIME PERIOD NOT LESS THAN THE REQUIRED FIRE-RESISTANCE RATING WHICH IT IS INSTALLED. 2. ALL JOINTS INSTALLED IN OR BETWEEN FIRE-RESISTIVE-RATED WALLS, FLOORS OR FLOOR/CEILING ASSEMBLIES AND ROOFS OR ROOF/CEILING ASSEMBLIES SHALL BE PROTECTED BY APPROVED FIRE-RESISTANT JOINT SYSTEM DESIGNED TO RESIST THE PASSAGE OF FIRE FOR A TIME PERIOD NOT LESS THAN THE REQUIRED FIRE-RESISTANCE RATING WHICH IT IS INSTALLED. (IBC 2012 Sec. 715) GENERAL FIRESTOPPING & JOINT NOTES: SCALE:1/8" = 1'-0"1 5-PLEX 2-STORY ROOF PLAN Rev. #Issue / RevisionDate330% Set12-03-2021NORTH ORIENTATION VARIES - REFER TO CIVIL FIRST FLOOR 0" TRUSS BEARING 9' - 1 1/8" STN VNL-1 VNL-1 VNL-1 RF VNL-1VNL-1 TRM VIS STN DS TRM VNL-3VNL-3 VNL-1 STN VIS VNL-1 VNL-3 VNL-1 VNL-3 FAS FAS FIRST FLOOR 0" TRUSS BEARING 9' - 1 1/8" VNL-3 VNL-1 FAS VIS TRM TRM DSDS TRM RF FIRST FLOOR 0" TRUSS BEARING 9' - 1 1/8"VNL-1 VNL-1 VIS VIS RF DS TRM GUT VNL-1 VNL-1VIS VIS VNL-2 VNL-2 VISVIS VIS FIRST FLOOR 0" TRUSS BEARING 9' - 1 1/8" TRM TRM TRM FAS VNL-3 VNL-1VISTRM RF FIRST FLOOR 0" TRUSS BEARING 9' - 1 1/8" ROOF PEAK - 1 STORY 21' - 6 3/4" FAS VNL-1TRM DS VNL-1 VNL-3 VNL-3 FAS VNL-3 VNL-1 STN TRM VNL-1 STN VNL-1 VNL-3 VNL-1 FAS RF VNL-3 VNL-3 STN VNL-1 STN VIS VNL-1 VNL-1 FIRST FLOOR 0" TRUSS BEARING 9' - 1 1/8" ROOF PEAK - 1 STORY 21' - 6 3/4" TRM DS VIS VNL-1 VIS VNL-1 VNL-2 VNL-2 VNL-2 VNL-2 VNL-1 VNL-1 VIS VIS VISVIS Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.SAA C:\Users\spoole\Documents\21113 Converge NW, Waukee, IA_3&4-Plex One-Story Townhouse_spoolePMDSN.rvt12/2/2021 3:26:26 PMCONVERGE NWTOWNHOUSESWAUKEE, IOWA21113 A-201 3/4-PLEX 1-STORY EXT. ELEVATIONS SP SCALE:1/8" = 1'-0"1 3-PLEX 1-STORY FRONT ELEVATION SCALE:1/8" = 1'-0"5 LEFT ELEVATION SCALE:1/8" = 1'-0"2 3-PLEX 1-STORY REAR ELEVATION SCALE:1/8" = 1'-0"6 RIGHT ELEVATION SCALE:1/8" = 1'-0"3 4-PLEX 1-STORY FRONT ELEVATION SCALE:1/8" = 1'-0"4 4-PLEX 1-STORY REAR ELEVATION Rev. #Issue / RevisionDate330% Set12-03-20211. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL CONDUIT RUNS & SERVICE LINES SHALL BE GROUPED TOGETHER IN A NEAT & ORDERLY MANNER AND SHOULD PENETRATE THE WALL AT THE LOWEST POINT AND ARE NOT TO RUN OVER THE TOP OF PARAPET. ALL OTHER CONDUITS & JUNCTION BOXES FOR EXTERIOR FIXTURES & EQUIPMENT SHALL BE FULLY CONCEALED WITHIN THE BUILDING CONSTRUCTION. 3. ALL HORIZONTAL TRANSITIONS BETWEEN DIFFERENT MATERIALS SHALL BE FLASHED CONTINUOUS FROM UP BEHIND UPPER MATERIAL AND EXTEND OVER TO EXTERIOR FACE OF LOWER MATERIAL WITH DRIP EDGE. 4. ANY RETURNS OR BLIND ELEVATIONS NOT SHOWN SHALL BE SIMILAR IN MATERIAL AND MAKEUP TO ADJACENT CONDITIONS OR OTHER SIMILAR CONDITIONS. 5. NO EXPOSED MASONRY/MATERIAL CORES. MASONRY RETURNS AT WINDOWS/OPENINGS ARE REQUIRED IF FRAMING IS NOT DEEP ENOUGH TO PROVIDE CLOSURE AT THE BACKSIDE OF MASONRY FOR AN EFFECTIVELY SEALED JOINT. 6. CAULK & SEAL ALL TRANSITION-CONTROL-EXPANSION AT ALL EXTERIOR MATERIALS. 7. PROVIDE CAST REGLETS JUST IN FROM THE OUTER EDGE ON UNDERSIDE OF FACE MATERIAL OR DRIP EDGE AT ALL OVERHANGS & SOFFITS. 8. INSULATE AND SEAL TO ENSURE ADEQUATE AIR INFILTRATION BARRIER AROUND ALL EXTERIOR PENETRATIONS TO PREVENT WATER AND SPRINKLER PIPE FREEZING. 9. WHERE EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF PAVING TO BE 1/4" LOWER THAN INTERIOR FINISH FLOOR, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. WHERE DOOR STOOP, 48" OUT FROM DOOR 1:48(2%) MAX. SLOPE, AFTER 48" AWAY FROM DOOR 1:20(5%) MAXIMUM SLOPE TO PUBLIC WAY. (REFER TO CIVIL) 10. WHERE NO EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF FINISHED LANDSCAPE A MINIMUM OF 4" BELOW INTERIOR FINISH FLOOR AND 4”BELOW EXTERIOR WALL FLASHING/WEEPS, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. (REFER TO CIVIL) 11. ADDRESS SHALL BE PROVIDED ON STREET SIDE OF BUILDING AND ON MONUMENT SIGN. NUMBERS A MINIMUM 5 INCH CONTRASTING COLOR NUMBERS WITH MINIMUM 1/2" STROKE. ACTUAL DETAILS & DIMENSIONS MAY VARY AND ARE SUBJECT TO CHANGE. ALL DRAWINGS ARE SUBJECT TO AUTHORITY HAVING JURISDICTION APPROVAL. SIGNAGE SHOWN DOES NOT REPRESENT ALLOWABLE SIGNAGE PERMITTING/APPROVAL OF ALL SIGNAGE PER CURRENT CITY ORDINANCE BY OTHERS. GENERAL EXTERIOR ELEVATION NOTES: EXTERIOR MATERIAL LEGEND MAT. LABEL MATERIAL DESCRIPTION DS PREFINISHED METAL DOWNSPOUT: WHITE FAS VINYL FASCIA BOARD, SMOOTH, COLOR - WHITE GUT PREFINISHED METAL GUTTER: WHITE RF ARCHITECTURAL ASPHALT ROOFING SHINGLES, COLOR - CHARCOAL STN CENTURION STONE, COASTAL OHIO LIMESTONE W/ ASSOCIATED STONE SILL CAP TRM VINYL TRIM BOARD, SMOOTH, COLOR - WHITE VIS INSULATED VISION GLASS: CLEAR W/ LOW E COATING IN VINYL RESIDENTIAL STYLE WINDOW VNL-1 VINYL LAP SIDING, 6" REVEAL, COLOR - WHITE VNL-2 VINYL LAP SIDING, 6" REVEAL, COLOR - GRAY VNL-3 VINYL LAP SIDING, 6" REVEAL, COLOR - LIGHT GRAY MISCELLANEOUS EXTERIOR MATERIAL FINISHES: TYPICAL U.O.N. • EXPOSED CONCRETE: GRIND SMOOTH & RUB/COAT WITH CEMENT SLURRY. • EXPOSED LINTELS: GALVANIZED & PAINTED TO MATCH ADJACENT MATERIAL ABOVE. • FASCIA & SOFFIT: METAL PREFINISHED TO MATCH ADJACENT ROOF COLOR. • GUTTERS & DOWNSPOUTS: METAL PREFINISHED WHITE. • CAULKS & SEALANTS: COLOR MATCHED TO ADJACENT MATERIAL. • HOLLOW METAL MAN DOORS & FRAMES: PAINTED TO MATCH ADJACENT MATERIAL. • GARAGE DOORS: METAL PRE-FINISHED WHITE. • LOUVERS: METAL PRE-FINISHED TO MATCH ADJACENT MATERIAL COLOR. • LIGHT FIXTURES: METAL PRE-FINISHED WHITE. • TRIM SIZES, TYP. U.O.N.: WINDOWS & DOORS 5-1/2” VERTICAL 5-1/2” HORIZONTAL 9-1/4” FIRST FLOOR 0" TRUSS BEARING 9' - 1 1/8" VNL-2 VNL-3 VNL-1 VNL-1 VNL-2 TRM TRM VIS TRM DSDSDS FAS FAS FCT ROOF PEAK - 1 STORY 24' - 6 3/4" RF TRM FIRST FLOOR 0" TRUSS BEARING 9' - 1 1/8" RF RF RF VNL-1 DS VIS VIS VNL-1 VNL-2 TRMTRM VIS ROOF PEAK - 1 STORY 24' - 6 3/4" VNL-2 VIS VISVNL-1 DS VIS VIS VNL-1TRMTRM VIS VNL-3 FIRST FLOOR 0" TRUSS BEARING 9' - 1 1/8" VNL-3RF VNL-1 FAS FAS ROOF PEAK - 1 STORY 24' - 6 3/4" TRM TRM VISVNL-1 VNL-1 TRM TRM VNL-2 FIRST FLOOR 0" TRUSS BEARING 9' - 1 1/8" VNL-1 STN VNL-1 STN VNL-3 VNL-1 VNL-2VNL-1 VNL-1 VIS TRM DS FAS ROOF PEAK - 1 STORY 24' - 6 3/4" VNL-1 VNL-3 VNL-2 FAS VNL-3 VNL-2 VNL-1 VIS STN VIS TRM DS STN STN VNL-1 RF GUT VNL-2 VNL-3 VNL-1 VNL-1 STN Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.SAA C:\Users\spoole\Documents\21113 Converge NW, Waukee, IA_5-Plex One-Story Townhouse_spoolePMDSN.rvt12/2/2021 3:22:43 PMCONVERGE NWTOWNHOUSESWAUKEE, IA21113 A-202 5-PLEX 1-STORY EXT. ELEVATIONS SP SCALE:1/8" = 1'-0"3 5-PLEX 1-STORY WEST ELEVATION SCALE:1/8" = 1'-0"2 5-PLEX 1-STORY NORTH ELEVATION SCALE:1/8" = 1'-0"4 5-PLEX 1-STORY EAST ELEVATION SCALE:1/8" = 1'-0"1 5-PLEX 1-STORY SOUTH ELEVATION'Rev. #Issue / RevisionDate330% Set12-03-20211. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL CONDUIT RUNS & SERVICE LINES SHALL BE GROUPED TOGETHER IN A NEAT & ORDERLY MANNER AND SHOULD PENETRATE THE WALL AT THE LOWEST POINT AND ARE NOT TO RUN OVER THE TOP OF PARAPET. ALL OTHER CONDUITS & JUNCTION BOXES FOR EXTERIOR FIXTURES & EQUIPMENT SHALL BE FULLY CONCEALED WITHIN THE BUILDING CONSTRUCTION. 3. ALL HORIZONTAL TRANSITIONS BETWEEN DIFFERENT MATERIALS SHALL BE FLASHED CONTINUOUS FROM UP BEHIND UPPER MATERIAL AND EXTEND OVER TO EXTERIOR FACE OF LOWER MATERIAL WITH DRIP EDGE. 4. ANY RETURNS OR BLIND ELEVATIONS NOT SHOWN SHALL BE SIMILAR IN MATERIAL AND MAKEUP TO ADJACENT CONDITIONS OR OTHER SIMILAR CONDITIONS. 5. NO EXPOSED MASONRY/MATERIAL CORES. MASONRY RETURNS AT WINDOWS/OPENINGS ARE REQUIRED IF FRAMING IS NOT DEEP ENOUGH TO PROVIDE CLOSURE AT THE BACKSIDE OF MASONRY FOR AN EFFECTIVELY SEALED JOINT. 6. CAULK & SEAL ALL TRANSITION-CONTROL-EXPANSION AT ALL EXTERIOR MATERIALS. 7. PROVIDE CAST REGLETS JUST IN FROM THE OUTER EDGE ON UNDERSIDE OF FACE MATERIAL OR DRIP EDGE AT ALL OVERHANGS & SOFFITS. 8. INSULATE AND SEAL TO ENSURE ADEQUATE AIR INFILTRATION BARRIER AROUND ALL EXTERIOR PENETRATIONS TO PREVENT WATER AND SPRINKLER PIPE FREEZING. 9. WHERE EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF PAVING TO BE 1/4" LOWER THAN INTERIOR FINISH FLOOR, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. WHERE DOOR STOOP, 48" OUT FROM DOOR 1:48(2%) MAX. SLOPE, AFTER 48" AWAY FROM DOOR 1:20(5%) MAXIMUM SLOPE TO PUBLIC WAY. (REFER TO CIVIL) 10. WHERE NO EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF FINISHED LANDSCAPE A MINIMUM OF 4" BELOW INTERIOR FINISH FLOOR AND 4”BELOW EXTERIOR WALL FLASHING/WEEPS, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. (REFER TO CIVIL) 11. ADDRESS SHALL BE PROVIDED ON STREET SIDE OF BUILDING AND ON MONUMENT SIGN. NUMBERS A MINIMUM 5 INCH CONTRASTING COLOR NUMBERS WITH MINIMUM 1/2" STROKE. ACTUAL DETAILS & DIMENSIONS MAY VARY AND ARE SUBJECT TO CHANGE. ALL DRAWINGS ARE SUBJECT TO AUTHORITY HAVING JURISDICTION APPROVAL. SIGNAGE SHOWN DOES NOT REPRESENT ALLOWABLE SIGNAGE PERMITTING/APPROVAL OF ALL SIGNAGE PER CURRENT CITY ORDINANCE BY OTHERS. GENERAL EXTERIOR ELEVATION NOTES: EXTERIOR MATERIAL LEGEND MAT. LABEL MATERIAL DESCRIPTION DS PREFINISHED METAL DOWNSPOUT: WHITE FAS VINYL FASCIA BOARD, SMOOTH, COLOR - WHITE GUT PREFINISHED METAL GUTTER: WHITE RF ARCHITECTURAL ASPHALT ROOFING SHINGLES, COLOR - CHARCOAL STN CENTURION STONE, COASTAL OHIO LIMESTON W/ ASSOCIATED STONE SILL CAP TRM VINYL TRIM BOARD, SMOOTH, COLOR - WHITE VIS INSULATED VISION GLASS: CLEAR W/ LOW E COATING IN VINYL RESIDENTIAL STYLE WINDOW VNL-1 VINYL LAP SIDING, 6" REVEAL, COLOR - WHITE VNL-2 VINYL LAP SIDING, 6" REVEAL, COLOR - GRAY VNL-3 VINYL LAP SIDING, 6" REVEAL, COLOR - LIGHT GRAY MISCELLANEOUS EXTERIOR MATERIAL FINISHES: TYPICAL U.O.N. • EXPOSED CONCRETE: GRIND SMOOTH & RUB/COAT WITH CEMENT SLURRY. • EXPOSED LINTELS: GALVANIZED & PAINTED TO MATCH ADJACENT MATERIAL ABOVE. • FASCIA & SOFFIT: METAL PREFINISHED TO MATCH ADJACENT ROOF COLOR. • GUTTERS & DOWNSPOUTS: METAL PREFINISHED WHITE. • CAULKS & SEALANTS: COLOR MATCHED TO ADJACENT MATERIAL. • HOLLOW METAL MAN DOORS & FRAMES: PAINTED TO MATCH ADJACENT MATERIAL. • GARAGE DOORS: METAL PRE-FINISHED WHITE. • LOUVERS: METAL PRE-FINISHED TO MATCH ADJACENT MATERIAL COLOR. • LIGHT FIXTURES: METAL PRE-FINISHED WHITE. • TRIM SIZES, TYP. U.O.N.: WINDOWS & DOORS 5-1/2” VERTICAL 5-1/2” HORIZONTAL 9-1/4” FIRST FLOOR 0" SECOND FLOOR 10' - 7 7/8" ROOF PEAK - 2 STORY 32' - 11 1/2" RF FAS 2 STORY ROOF BEARING 19' - 9" VNL-1 VIS VNL-3 VNL-2 VNL-1 VNL-1 TRM TRM TRM TRM FAS FIRST FLOOR 0" SECOND FLOOR 10' - 7 7/8" ROOF PEAK - 2 STORY 32' - 11 1/2" RF VNL-3 VNL-1 VNL-1 VNL-1 RF RF VIS VIS TRM VIS TRM 2 STORY ROOF BEARING 19' - 9" TRM VNL-1 VNL-1TRM DS GUT TRM VNL-2 VNL-1 GUT TRM TRM VIS VIS FIRST FLOOR 0" SECOND FLOOR 10' - 7 7/8" ROOF PEAK - 2 STORY 32' - 11 1/2" VNL-1 TRM VNL-3 VIS TRM FAS FAS VNL-1 2 STORY ROOF BEARING 19' - 9" VNL-1 VNL-1 VNL-2 TRM TRM FIRST FLOOR 0" SECOND FLOOR 10' - 7 7/8" ROOF PEAK - 2 STORY 32' - 11 1/2" RF STN VNL-1 STN STN VNL-3 RF FAS VNL-1 VNL-3 VNL-1 VNL-1 VNL-1 VNL-3 VNL-2 VNL-3 VIS TRM VIS TRM RF RF 2 STORY ROOF BEARING 19' - 9" FAS VNL-2 TRM STN VNL-1 VNL-1 VNL-3 VIS TRM Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.SAA C:\Users\spoole\Documents\21113 Converge NW, Waukee, IA_4-Plex Two-Story Townhouse_spoolePMDSN.rvt12/2/2021 3:19:20 PMCONVERGE NWTOWNHOUSESWAUKEE, IA21113 A-203 4-PLEX 2-STORY EXT. ELEVATIONS SP SCALE:1/8" = 1'-0"3 4-PLEX 2-STORY RIGHT ELEVATION SCALE:1/8" = 1'-0"2 4-PLEX 2-STORY REAR ELEVATION SCALE:1/8" = 1'-0"4 4-PLEX 2-STORY LEFT ELEVATION SCALE:1/8" = 1'-0"1 4-PLEX 2-STORY FRONT ELEVATION Rev. #Issue / RevisionDate330% Set12-03-20211. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL CONDUIT RUNS & SERVICE LINES SHALL BE GROUPED TOGETHER IN A NEAT & ORDERLY MANNER AND SHOULD PENETRATE THE WALL AT THE LOWEST POINT AND ARE NOT TO RUN OVER THE TOP OF PARAPET. ALL OTHER CONDUITS & JUNCTION BOXES FOR EXTERIOR FIXTURES & EQUIPMENT SHALL BE FULLY CONCEALED WITHIN THE BUILDING CONSTRUCTION. 3. ALL HORIZONTAL TRANSITIONS BETWEEN DIFFERENT MATERIALS SHALL BE FLASHED CONTINUOUS FROM UP BEHIND UPPER MATERIAL AND EXTEND OVER TO EXTERIOR FACE OF LOWER MATERIAL WITH DRIP EDGE. 4. ANY RETURNS OR BLIND ELEVATIONS NOT SHOWN SHALL BE SIMILAR IN MATERIAL AND MAKEUP TO ADJACENT CONDITIONS OR OTHER SIMILAR CONDITIONS. 5. NO EXPOSED MASONRY/MATERIAL CORES. MASONRY RETURNS AT WINDOWS/OPENINGS ARE REQUIRED IF FRAMING IS NOT DEEP ENOUGH TO PROVIDE CLOSURE AT THE BACKSIDE OF MASONRY FOR AN EFFECTIVELY SEALED JOINT. 6. CAULK & SEAL ALL TRANSITION-CONTROL-EXPANSION AT ALL EXTERIOR MATERIALS. 7. PROVIDE CAST REGLETS JUST IN FROM THE OUTER EDGE ON UNDERSIDE OF FACE MATERIAL OR DRIP EDGE AT ALL OVERHANGS & SOFFITS. 8. INSULATE AND SEAL TO ENSURE ADEQUATE AIR INFILTRATION BARRIER AROUND ALL EXTERIOR PENETRATIONS TO PREVENT WATER AND SPRINKLER PIPE FREEZING. 9. WHERE EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF PAVING TO BE 1/4" LOWER THAN INTERIOR FINISH FLOOR, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. WHERE DOOR STOOP, 48" OUT FROM DOOR 1:48(2%) MAX. SLOPE, AFTER 48" AWAY FROM DOOR 1:20(5%) MAXIMUM SLOPE TO PUBLIC WAY. (REFER TO CIVIL) 10. WHERE NO EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF FINISHED LANDSCAPE A MINIMUM OF 4" BELOW INTERIOR FINISH FLOOR AND 4”BELOW EXTERIOR WALL FLASHING/WEEPS, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. (REFER TO CIVIL) 11. ADDRESS SHALL BE PROVIDED ON STREET SIDE OF BUILDING AND ON MONUMENT SIGN. NUMBERS A MINIMUM 5 INCH CONTRASTING COLOR NUMBERS WITH MINIMUM 1/2" STROKE. ACTUAL DETAILS & DIMENSIONS MAY VARY AND ARE SUBJECT TO CHANGE. ALL DRAWINGS ARE SUBJECT TO AUTHORITY HAVING JURISDICTION APPROVAL. SIGNAGE SHOWN DOES NOT REPRESENT ALLOWABLE SIGNAGE PERMITTING/APPROVAL OF ALL SIGNAGE PER CURRENT CITY ORDINANCE BY OTHERS. GENERAL EXTERIOR ELEVATION NOTES: EXTERIOR MATERIAL LEGEND MAT. LABEL MATERIAL DESCRIPTION DS PREFINISHED METAL DOWNSPOUT: WHITE FAS VINYL FASCIA BOARD, SMOOTH, COLOR - WHITE GUT PREFINISHED METAL GUTTER: WHITE RF ARCHITECTURAL ASPHALT ROOFING SHINGLES, COLOR - CHARCOAL STN CENTURION STONE, COASTAL OHIO LIMESTONE W/ ASSOCIATED STONE SILL CAP TRM VINYL TRIM BOARD, SMOOTH, COLOR - WHITE VIS INSULATED VISION GLASS: CLEAR W/ LOW E COATING IN VINYL RESIDENTIAL STYLE WINDOW VNL-1 VINYL LAP SIDING, 6" REVEAL, COLOR - WHITE VNL-2 VINYL LAP SIDING, 6" REVEAL, COLOR - GRAY VNL-3 VINYL LAP SIDING, 6" REVEAL, COLOR - LIGHT GRAY MISCELLANEOUS EXTERIOR MATERIAL FINISHES: TYPICAL U.O.N. • EXPOSED CONCRETE: GRIND SMOOTH & RUB/COAT WITH CEMENT SLURRY. • EXPOSED LINTELS: GALVANIZED & PAINTED TO MATCH ADJACENT MATERIAL ABOVE. • FASCIA & SOFFIT: METAL PREFINISHED TO MATCH ADJACENT ROOF COLOR. • GUTTERS & DOWNSPOUTS: METAL PREFINISHED WHITE. • CAULKS & SEALANTS: COLOR MATCHED TO ADJACENT MATERIAL. • HOLLOW METAL MAN DOORS & FRAMES: PAINTED TO MATCH ADJACENT MATERIAL. • GARAGE DOORS: METAL PRE-FINISHED WHITE. • LOUVERS: METAL PRE-FINISHED TO MATCH ADJACENT MATERIAL COLOR. • LIGHT FIXTURES: METAL PRE-FINISHED WHITE. • TRIM SIZES, TYP. U.O.N.: WINDOWS & DOORS 5-1/2” VERTICAL 5-1/2” HORIZONTAL 9-1/4” REF. WD DW GARAGE 003 LIVING 011 BEDROOM 006 BEDROOM 012 ENTRY 001 KITCHEN 008 WIC 014 MECH. 005 LAUNDRY 004 BATH 010 BATH 013 WIC 007 CLOSET002CLOSET0094 003.1 001 004 005 006 007 009 010 013 012 002 003 1/4" PER FT, TYPA-411 2 3 4 A-411 5 6 A-411 7 123 9 6 10 8 11 5 3 123 12 6 5 5 5 5 7 1' - 0" 2 1/8" 3' - 9"1' - 6"3' - 0" 1"3' - 0"1' - 6"1' - 3"1' - 3"6' - 0"1' - 0"7' - 0"2' - 0" 2 1/8" 2' - 9"1' - 6"3' - 1" 1' - 0" 2' - 9" 2' - 6" 2' - 9" 2' - 3"2' - 6"1' - 6"3' - 0"2' - 0" 3" 1' - 6" 2' - 6" 1' - 6" 3" 2' - 0"1' - 3"1' - 3"1' - 6"3' - 0"3"2' - 0"3' - 0"1' - 9"3"2' - 0"33"-36"1' - 0" 1' - 0" CRITICAL 1' - 6"1' - 6 1/2"1' - 0"2' - 0"1' - 0" 1"33"-36"1' - 0" 3' - 6" 6' - 7 1/2" 2' - 6"33"-36"MIN. 15 3/4" MIN. 15 3/4" 2" 2' - 3" 1' - 0" 2' - 3" 1' - 7 1/2" 1' - 8" 2' - 6" 12" 12"33"-36"24" 12"33"-36"24" GRAB BAR 36" GRAB BAR MIN. 15 3/4" MIN. 15 3/4" 12" 42" MIN.33"-36"SWING UP GRAB BAR SIDE GRAB BAR 12" MIN.NOTE: ALL GRAB BAR BLOCKING SHALL BE MIN 2X8 WOOD BLOCKING TO ENSURE ADEQUATE COVERAGE FOR MIN 6" BLOCKING REQUIREMENTS. ALL BLOCKING TO BE VERTICALLY CENTERED ON GRAB BAR.33"-36"TUB- BACK WALL TUB- CONTROL WALL TUB- HEAD END WALL INSTALL BLOCKING FOR FUTURE GRAB BARS INSTALL BLOCKING FOR FUTURE GRAB BARS INSTALL BLOCKING FOR FUTURE GRAB BARS INSTALL BLOCKING FOR CONTROLST.O. BAR33"-36"MAX.32"MIN.6"12- 24"MAX.32"33- 36"3" -6"MIN.18"8" -10"T.O. BAR33"-36"MIN. 24" 12" MAX 24" MIN.24" MAX MAX6"T.O. BAR33"-36"4" MAX. CL NOTE: ALL GRAB BAR BLOCKING SHALL BE MIN 2X8 WOOD BLOCKING TO ENSURE ADEQUATE COVERAGE FOR MIN 6" BLOCKING REQUIREMENTS. ALL BLOCKING TO BE VERTICALLY CENTERED ON GRAB BAR. Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.SAA C:\Users\spoole\Documents\21113 Converge NW, Waukee, IA_5-Plex One-Story Townhouse_spoolePMDSN.rvt12/2/2021 3:22:44 PMCONVERGE NWTOWNHOUSESWAUKEE, IA21113 A-411 TYPE 2A UNIT PLAN SP SCALE:1/4" = 1'-0"1 TYPE 2A UNIT FLOOR PLAN TYPE 2A DOOR & FRAME SCHEDULE DOOR NO.ROOM NAME DOOR FRAME HARDWARE REMARKS (ALSO SEE NOTES)UNITTYPE PAIR WIDTH HEIGHT MAT'L TYPE RATING MAT'L CLOSER THLD 001 ENTRY P3 No 3' - 0" 6' - 8" VINYL 1 VINYL Yes Yes ENTRY LOCK 2A 002 CLOSET P2 No 2' - 6" 6' - 8" WOOD 2 WOOD No No PASSAGE 2A 003 OHD No 16' - 0" 7' - 0" STEEL -- -- PUSH BUTTON, 2 REMOTES 2A 003.1 GARAGE P2 No 3' - 0" 6' - 8" WOOD 2 WOOD Yes No ENTRY LOCK 2A 004 LAUNDRY P2 No 2' - 10" 6' - 8" WOOD 2 WOOD No No PASSAGE 2A 005 MECH. P2 Yes 5' - 0" 6' - 8" WOOD 2 WOOD No No PASSAGE 2A 006 BEDROOM P2 No 2' - 10" 6' - 8" WOOD 2 WOOD No No PASSAGE 2A 007 WIC P2 No 2' - 10" 6' - 8" WOOD 2 WOOD No No PASSAGE 2A 009 CLOSET P2 No 2' - 0" 6' - 8" WOOD 2 WOOD No No PASSAGE 2A 010 BATH P2 No 2' - 10" 6' - 8" WOOD 2 WOOD No No PRIVACY LOCK 2A 012 BEDROOM P2 No 2' - 10" 6' - 8" WOOD 2 WOOD No No PASSAGE 2A 013 BATH P2 No 2' - 10" 6' - 8" WOOD 2 WOOD No No PRIVACY LOCK 2A UNIT PLAN KEYNOTES LABEL REMARKS 1 REFER TO OVERALL BUILDING PLANS FOR SPECIFIC WINDOW TYPE & LOCATION, TYP. 2 WINDOWS TO RECEIVE DRYWALL SILL & RETURNS TO MATCH ADJ. WALL, TYP. 3 INSTALL WINDOW BLINDS, SIZED TO FIT WINDOW, AT ALL WINDOW LOCATIONS; SPECIFIC T.B.D., TYP. 4 REFER TO OVERALL BUILDING PLANS FOR DECK/PATIO SIZE, DETAILS, ETC. 5 COATED WIRE SHELF W/ INTEGRAL HANGING ROD - 12" DEEP 6 (2 LAYERS) COATED WIRE SHELF WITH INTEGRAL HANGING ROD - 12" DEEP; TOP OF LOWER SHELF AND ROD TO BE INSTALLED AT 48" AFF MAXIMUM 7 (5 LAYERS) COATED WIRE SHELF - 16" DEEP; TOP OF 3 LAYERS TO BE INSTALLED BETWEEN 15"-48" AFF 8 UNIT ENTRY DOOR; REFER TO DETAIL #3 ON SHEET G-011 FOR MINIMUM DOOR CLEARANCES 9 REFER TO OVERALL BUILDING PLANS FOR SPECIFIC PATIO DOOR LOCATION 10 MECHANICAL EQUIPMENT SHOWN FOR COORDINATION PURPOSES ONLY; ALL MEP SCOPE IS DESIGN-BUILD BY CONTRACTOR 11 STEEL COUNTERTOP BRACKET - SIZED APPROPRIATELY PER OVERHANG, TYP. 12 36" X 80" CASED OPENING 13 COAT HOOKS INSTALLED @ 66" AFF OVER STAINED WOOD RAIL 14 18" DEEP WOOD BENCH W/ CUBBIES & COAT HOOKS INSTALLED @ 66" AFF OVER STAINED WOOD RAIL GARAGE 20 MIN.Rev. #Issue / RevisionDate330% Set12-03-2021SCALE:1/2" = 1'-0"2 TYPE 2A - KITCHEN 1 SCALE:1/2" = 1'-0"3 TYPE 2A - KITCHEN 2 SCALE:1/2" = 1'-0"4 TYPE 2A - KITCHEN 3 SCALE:1/2" = 1'-0"5 TYPE 2A - BATH 1 SCALE:1/2" = 1'-0"6 TYPE 2A - BATH 2 SCALE:1/2" = 1'-0"7 TYPE 2A - M. BATH TOILET GRAB BARS SHOWER / TUB GRAB BARS W D DW REF. KITCHEN 012 DEN 007 BEDROOM 010 M. BATH 008 WIC 009 BATH 004 BEDROOM 002 CL0SET 003 LAUNDRY 005 LIVING 011 GARAGE 013 LIN. ENTRY 00111' - 1 3/8"4 1/2"12' - 8"2' - 8"6 1/2"7' - 4"4 1/2"5' - 0"6 1/2"2' - 0"4 1/2"9' - 11 7/8"6' - 0"5' - 1 3/8"4 1/2"5' - 5 1/2"4 1/2"9' - 6"4 1/2"3' - 6 1/4"9' - 10 3/4"9' - 4 3/8"15' - 7 3/4" 4 1/2" 4" 6' - 0" 4 1/2" 8' - 11 5/8" 4 1/2" 19' - 3 7/8" 6' - 0" 4 1/2" 3' - 3 5/8" 4 1/2" 5' - 8 1/4" 6 1/2" 19' - 1 1/8" 3' - 0" 4 1/2" 6' - 4" 1' - 8" 4 1/2" 3' - 11 7/8" 5' - 5 5/8" 4 1/2"16' - 10 3/4"4 1/2"9' - 2"6 1/2"20' - 0"52' - 11 3/4"6' - 0"46' - 11 3/4"5' - 0"MECH. 006 9' - 8 1/8" 6' - 7 1/4" 11' - 4 1/2" A-412 3 2 A-412 4 LIN. A-4125 1 2 3 6 5 5 5 10 1 2 3 9 4 3 11 8 14 001 002 003 004 005 006 007 008 010 013.1 013 2' - 0" 3' - 0" 2' - 6" 3' - 0" 3' - 3" 2' - 0" 3' - 0" 2' - 6" 3' - 0" 3' - 3"3' - 0"4"1' - 2"2' - 6"7' - 0"2' - 6"2' - 0"3' - 3"2' - 0"3' - 0"2' - 6"1' - 7"1' - 6 1/2"3' - 0"1' - 0"1' - 9"2' - 10"4"3' - 6"7' - 0"4' - 0" MIN. 15 3/4" MIN. 15 3/4"33"-36"2' - 6" 2" 2' - 1" 2' - 1" 2' - 6" 1' - 0" 2' - 6" 2' - 6" 6' - 0"3' - 6"4"2' - 10"7' - 0"MIN. 15 3/4" MIN. 15 3/4"33"-36"Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.SAA C:\Users\spoole\Documents\21113 Converge NW, Waukee, IA_3&4-Plex One-Story Townhouse_spoolePMDSN.rvt12/2/2021 3:26:28 PMCONVERGE NWTOWNHOUSESWAUKEE, IOWA21113 A-412 UNIT 2B+D UNIT PLAN SP UNIT PLAN KEYNOTES LABEL REMARKS 1 REFER TO OVERALL BUILDING PLANS FOR SPECIFIC WINDOW TYPE & LOCATION, TYP. 2 WINDOWS TO RECEIVE DRYWALL SILL & RETURNS TO MATCH ADJ. WALL, TYP. 3 INSTALL WINDOW BLINDS, SIZED TO FIT WINDOW, AT ALL WINDOW LOCATIONS; SPECIFIC T.B.D., TYP. 4 REFER TO OVERALL BUILDING PLANS FOR DECK/PATIO SIZE, DETAILS, ETC. 5 COATED WIRE SHELF W/ INTEGRAL HANGING ROD - 12" DEEP 6 (2 LAYERS) COATED WIRE SHELF WITH INTEGRAL HANGING ROD - 12" DEEP; TOP OF LOWER SHELF AND ROD TO BE INSTALLED AT 48" AFF MAXIMUM 7 (5 LAYERS) COATED WIRE SHELF - 16" DEEP; TOP OF 3 LAYERS TO BE INSTALLED BETWEEN 15"-48" AFF 8 UNIT ENTRY DOOR; REFER TO DETAIL #3 ON SHEET G-011 FOR MINIMUM DOOR CLEARANCES 9 REFER TO OVERALL BUILDING PLANS FOR SPECIFIC PATIO DOOR LOCATION 10 MECHANICAL EQUIPMENT SHOWN FOR COORDINATION PURPOSES ONLY; ALL MEP SCOPE IS DESIGN-BUILD BY CONTRACTOR 11 STEEL COUNTERTOP BRACKET - SIZED APPROPRIATELY PER OVERHANG, TYP. 12 36" X 80" CASED OPENING 13 COAT HOOKS INSTALLED @ 66" AFF OVER STAINED WOOD RAIL 14 18" DEEP WOOD BENCH W/ CUBBIES & COAT HOOKS INSTALLED @ 66" AFF OVER STAINED WOOD RAIL Rev. #Issue / RevisionDate330% Set12-03-2021SCALE:1/4" = 1'-0"1 TYPE 2B+D UNIT FLOOR PLAN SCALE:1/2" = 1'-0"2 UNIT 2B+D KITCHEN ELEVATION 1 SCALE:1/2" = 1'-0"3 UNIT 2B+D KITCHEN ELEVATION 2 SCALE:1/2" = 1'-0"4 UNIT 2B+D BATHROOM ELEVATION SCALE:1/2" = 1'-0"5 UNIT 2B+D M. BATHROOM ELEVATION 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. DIMENSIONS ARE TO FACE OF FINISH MATERIAL AND CENTER OF DOOR UNLESS OTHERWISE SPECIFIED. 3. MECHANICAL, ELECTRICAL, PLUMPING, FIRE SPRINKLER, FIRE/SMOKE ALARM SCOPE IS TO BE DESIGN/BUILD BY CONTRACTOR. FIXTURES AND EQUIPMENT SHOWN IS PROVIDED FOR COORDINATION PURPOSES ONLY. THE LAYOUT IS CONSIDERED CONCEPTUAL. REFER TO OTHER CONSULTANT & CONTRACTOR DOCUMENTS FOR SPECIFIC DESIGN INFORMATION. 4. ALL INTERIOR WALLS OF UNIT ARE TO BE WALL TYPE 6, UNLESS OTHERWISE SPECIFIED. SEE SHEET A-101 FOR WALL TYPES. 5. ALL CONDUITS, PIPES, WIRING, ROUGH-IN, ETC. SHOULD BE HELD AS TIGHT AS POSSIBLE TO THE ROOF OR FLOOR DECK OR SHOULD BE KEPT WITHIN INTERIOR WALL AND FLOOR/CEILING CAVITIES. NOTHING SHALL BE EXPOSED IN FINISHED SPACES, NOTHING SHALL PREVENT A SMOOTH CONTINUOUS FINISHED WALL OR CEILING AS NOTED ON THE DRAWINGS AND NO PLUMBING RAN IN EXTERIOR WALLS UNLESS PRIOR APPROVAL IS GRANTED BY THE ARCHITECT OR OWNER. PLACEMENT COORDINATION BETWEEN TRADES IS REQUIRED. 6. FLOORING TO BE COMPLETE UNDER RANGE & REFRIGERATOR. 7. ALL APARTMENTS ARE ANSI A-117 CH.10 TYPE B UNITS UNLESS OTHERWISE INDICATED. 8. INSTALL AN EXHAUST FAN IN EACH BATHROOM AS REQUIRED BY CODE. EXTEND EXHAUST TO OUTSIDE AIR CODE REQUIREMENTS. 9. REFER TO ACCESSIBILITY MATRIX FOR ACCESSIBLE, TYPE A, TYPE B, TYPE C & ACCESSIBLE COMMUNICATION UNIT REQUIREMENTS. 10. KITCHEN CABINETRY LAYOUTS ARE CONCEPTUAL ONLY. VERIFY FINAL LAYOUTS WITH OWNER PRIOR TO CONSTRUCTION. 11. INSTALL VERTICAL CONTROL JOINT FOR GYPSUM BOARD WALLS AT THE HEAD OF DOOR JAMBS/OPENINGS (ONE SIDE ONLY) OR AS OTHERWISE NOTED OR WHERE REQUIRED PER STANDARD MATERIAL PRACTICE (IN WALLS GREATER THAN 24') TO REDUCE STRESS CRACKING. 12. PROVIDE ADEQUATE WOOD BLOCKING FOR MILLWORK, FIXTURES, EQUIPMENT, PLUMBING FIXTURES AND ACCESSORIES, ELECTRIC PANELS, ETC. 13. AT ALL UNITS WHERE THE WASHER & DRYER ARE LOCATED IN A DEDICATED CLOSET, PROVIDE A RETURN AIR GRILLE IN THE WALL ABOVE THE DOOR HEADER SIZED TO PROVIDE ADEQUATE VENTILATION FOR PROPER WASHER & DRYER OPERATION. 14. ALL LAUNDRY, UTILITY, & MECH ROOMS SHALL RECEIVE EPOXY PAINT THROUGHOUT THE ENTIRE ROOM. GENERAL UNIT PLAN NOTES TYPE 2B+D DOOR & FRAME SCHEDULE DOOR NO.ROOM NAME DOOR FRAME HARDWARE REMARKS (ALSO SEE NOTES)UNITTYPE PAIR WIDTH HEIGHT MAT'L TYPE RATING MAT'L CLOSER THLD 001 ENTRY P3 No 3' - 0" 6' - 8" VINYL 1 VINYL Yes Yes ENTRY DOOR 2BD 002 BEDROOM P2 No 2' - 10" 6' - 8" WOOD 2 WOOD No No PRIVACY LOCK 2BD 003 CL0SET SP2 Yes 5' - 0" 6' - 8" WOOD 2 WOOD No No BYPASS, PASSAGE 2BD 004 BATH P2 No 2' - 6" 6' - 8" WOOD 2 WOOD No No PRIVACY LOCK 2BD 005 LAUNDRY P2 No 2' - 10" 6' - 8" WOOD 2 WOOD No No PRIVACY LOCK 2BD 006 MECH. SP2 Yes 5' - 0" 6' - 8" WOOD 2 WOOD No No BYPASS, PASSAGE 2BD 007 DEN P2 Yes 6' - 0" 6' - 8" WOOD 2 WOOD No No PASSAGE 2BD 008 M. BATH P2 No 2' - 10" 6' - 8" WOOD 2 WOOD No No PRIVACY LOCK 2BD 010 BEDROOM P2 No 2' - 10" 6' - 8" WOOD 2 WOOD No No PASSAGE 2BD 013 OHD No 16' - 0" 7' - 0" -- -- GARAGE DOOR 2BD 013.1 GARAGE P2 No 3' - 0" 6' - 8" WOOD 2 WOOD Yes No ENTRY LOCK 2BD GARAGE 20 MIN. REF.WDDW LIVING 012 KITCHEN 009 BEDROOM 013 BEDROOM 007 BEDROOM 004 WIC 015 LAUNDRY 010 MECH. 002 CLOSET 008 LIN.016BATH 014 ENTRY 001 012 011 005 004 003 002 006 007 008 014 013 010 011.1 BATH 003 CLOSET 006 CLOSET005016 7 6 2 3 22 2 6 6 6 6 6 6 6 6 6 6 6 7 6 8 6 6 6 1 2 2 7 6 7 9 6 A-413 3 2 A-413 4 A-4135 1 2 3 9 6 10 8 11 4 3 1 2 3 5 1 2 3 1 2 3 19' - 3 7/8"15' - 7 3/4"11' - 11 3/4"5' - 5 1/2"2' - 0"10' - 6"10' - 1 1/2"5' - 11 3/4"15' - 11 7/8"9' - 11 7/16"19' - 11 1/2"46' - 11 3/4"5' - 2 1/2"3' - 3 1/4" 3' - 3 1/8"5' - 0" 2' - 0 1/2"3' - 10 1/2"2' - 11 1/2"5' - 8 1/8"3' - 9 1/4"12' - 0 3/4" 10' - 2" 7' - 10 3/8" 3' - 3 1/4"2' - 0"15' - 7 3/4"6' - 1"5' - 7 3/4"3' - 0 3/4"12' - 10 3/4"2' - 1 1/2"2' - 9"5 5 5 5 7 6 6 6 9 6 6 6 6 7 6 6 9' - 0 7/8"6' - 3" 3' - 3 1/4"2' - 6"1' - 11 1/8"5' - 0" 3 1/2"2' - 10"1 5/8" ENTRY 00111' - 0 1/2"(40" MIN.)4' - 2 1/2"1' - 0 1/2"GARAGE 011 001 9"3' - 3"2' - 0"3" DISHWASHER END PANEL 3' - 0"1 1/2"3' - 3"1 3/4"3' - 0" 2' - 6" 3' - 9" 3' - 6 1/4" 3' - 0" 2' - 6" 3' - 9"3' - 0"4"1' - 2"2' - 6"6' - 0"1' - 0"FILLER, TYP.FILLER, TYP.7' - 0"3' - 6"4"2' - 10"2' - 6" 1' - 0" 2' - 6" 1' - 10" 1' - 10 1/4" 2' - 6" MIN. 15 3/4" MIN 15 3/4" 6' - 0"3' - 6"4"2' - 10"MIN. 15 3/4" MIN 15 3/4" 2' - 6" 1' - 9" 1' - 10 1/2" 3' - 0" 1' - 0" 2' - 6"6' - 8"4' - 0" Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.SAA C:\Users\spoole\Documents\21113 Converge NW, Waukee, IA_5-Plex One-Story Townhouse_spoolePMDSN.rvt12/2/2021 3:22:45 PMCONVERGE NWTOWNHOUSESWAUKEE, IA21113 A-413 TYPE 3A UNIT PLAN SP TYPE 3A DOOR & FRAME SCHEDULE DOOR NO.ROOM NAME DOOR FRAME HARDWARE REMARKS (ALSO SEE NOTES)UNITTYPE PAIR WIDTH HEIGHT MAT'L TYPE RATING MAT'L CLOSER THLD 001 P3 No 3' - 0" 6' - 8" VINYL 1 VINYL Yes Yes ENTRY DOOR 3A 002 MECH. P2 Yes 5' - 0" 6' - 8" WOOD 2 WOOD No No PASSAGE 3A 003 BATH P2 No 2' - 10" 6' - 8" WOOD 2 WOOD No No PRIVACY LOCK 3A 004 BEDROOM P2 No 2' - 10" 6' - 8" WOOD 2 WOOD No No PASSAGE 3A 005 CLOSET SP2 Yes 5' - 0" 6' - 8" WOOD 2 WOOD No No BYPASS, PASSAGE 3A 006 CLOSET P2 No 2' - 6" 6' - 8" WOOD 2 WOOD No No PASSAGE 3A 007 BEDROOM P2 No 2' - 10" 6' - 8" WOOD 2 WOOD No No PASSAGE 3A 008 CLOSET SP2 Yes 5' - 0" 6' - 8" WOOD 2 WOOD No No BYPASS, PASSAGE 3A 010 LAUNDRY P2 No 2' - 10" 6' - 8" WOOD 2 WOOD No No PASSAGE 3A 011 OHD No 16' - 0" 7' - 0" STEEL -- -- PUSH BUTTON, 2 REMOTES 3A 011.1 GARAGE P2 No 3' - 0" 6' - 8" WOOD 2 WOOD Yes No ENTRY LOCK 3A 012 LIVING SL Yes 6' - 0" 6' - 8" VINYL 1 VINYL No Yes INTERIOR SLIDE LOCK 3A 013 BEDROOM P2 No 2' - 10" 6' - 8" WOOD 2 WOOD No No PASSAGE 3A 014 BATH P2 No 2' - 10" 6' - 8" WOOD 2 WOOD No No PRIVACY LOCK 3A 016 LIN. P2 No 2' - 6" 6' - 8" WOOD 2 WOOD No No PASSAGE 3A SCALE:1/4" = 1'-0"1 TYPE 3A UNIT FLOOR PLAN SCALE:1/2" = 1'-0"2 TYPE 3A - ISLAND SCALE:1/2" = 1'-0"3 TYPA 3A - KITCHEN SCALE:1/2" = 1'-0"4 TYPE 3A - BATHROOM SCALE:1/2" = 1'-0"5 TYPE 3A - BATHROOM 2 GARAGE 20 MIN.Rev. #Issue / RevisionDate330% Set12-03-2021UNIT PLAN KEYNOTES LABEL REMARKS 1 REFER TO OVERALL BUILDING PLANS FOR SPECIFIC WINDOW TYPE & LOCATION, TYP. 2 WINDOWS TO RECEIVE DRYWALL SILL & RETURNS TO MATCH ADJ. WALL, TYP. 3 INSTALL WINDOW BLINDS, SIZED TO FIT WINDOW, AT ALL WINDOW LOCATIONS; SPECIFIC T.B.D., TYP. 4 REFER TO OVERALL BUILDING PLANS FOR DECK/PATIO SIZE, DETAILS, ETC. 5 COATED WIRE SHELF W/ INTEGRAL HANGING ROD - 12" DEEP 6 (2 LAYERS) COATED WIRE SHELF WITH INTEGRAL HANGING ROD - 12" DEEP; TOP OF LOWER SHELF AND ROD TO BE INSTALLED AT 48" AFF MAXIMUM 7 (5 LAYERS) COATED WIRE SHELF - 16" DEEP; TOP OF 3 LAYERS TO BE INSTALLED BETWEEN 15"-48" AFF 8 UNIT ENTRY DOOR; REFER TO DETAIL #3 ON SHEET G-011 FOR MINIMUM DOOR CLEARANCES 9 REFER TO OVERALL BUILDING PLANS FOR SPECIFIC PATIO DOOR LOCATION 10 MECHANICAL EQUIPMENT SHOWN FOR COORDINATION PURPOSES ONLY; ALL MEP SCOPE IS DESIGN-BUILD BY CONTRACTOR 11 STEEL COUNTERTOP BRACKET - SIZED APPROPRIATELY PER OVERHANG, TYP. 12 36" X 80" CASED OPENING 13 COAT HOOKS INSTALLED @ 66" AFF OVER STAINED WOOD RAIL 14 18" DEEP WOOD BENCH W/ CUBBIES & COAT HOOKS INSTALLED @ 66" AFF OVER STAINED WOOD RAIL DW REF. W D BEDROOM 002 BEDROOM 005 GARAGE 015 WIC 009 M. BATHROOM 008 BEDROOM 010 LAUNDRY 007 LIVING 011 KITCHEN 012 LAUNDRY 014 ENTRY 001 BATH 004 MECH. 013 CLOSET 003 CLOSET 00610' - 7 7/8"4 1/2"9' - 0"2' - 8"4 1/2"2' - 0"4 1/2"9' - 3"4 1/2"5' - 0"6 1/2"2' - 0"4 1/2"9' - 11 7/8"6' - 0"4' - 7 7/8"4 1/2"4' - 9 1/2"4 1/2"1' - 2"4 1/2"7' - 4"15' - 6 1/2"9' - 4 3/8"6' - 0" 4 1/2" 3' - 3 1/4" 4 1/2" 5' - 7 3/4" 6 1/2" 19' - 1 5/8" 11' - 10 5/8" 4 1/2" 3' - 4 7/8" 6 1/2" 13' - 5 1/8" 4 1/2" 5' - 4" 6' - 4 1/8" 4 1/2" 5' - 2" 4 1/2" 6' - 4 1/8" 4 1/2" 8' - 11 1/8" 4 1/2" 19' - 3 7/8" 15' - 7 3/4" 4 1/2" 19' - 3 7/8"20' - 0"6 1/2"7' - 8 1/4"4 1/2"3' - 0"4 1/2"15' - 0"52' - 11 3/4"46' - 11 3/4"6' - 0"9' - 7 3/4" 6' - 7 1/4"19' - 1 1/8" LIN. 35' - 4 1/8" A-414 3 2 A-4145 A-414 4 14 13 6 5 5 5 5 7 10 8 11 1 2 3 9 4 3 1 2 3 001 002 003 004 005 015.1 015 014 007 006 008 010 013 12 3' - 3" 3' - 0" 2' - 6" 3' - 0" 2' - 0" 2' - 0"3' - 0"2' - 6"3' - 0"3' - 3" 13' - 9"3' - 0"4"1' - 2"2' - 6"7' - 0"3' - 0"2' - 0"3' - 3"2' - 0"2' - 6"2' - 0" 1' - 0" 3' - 0" 1' - 8 5/8" 1' - 8" 2' - 6" 4' - 0"2' - 10"4"3' - 6"7' - 0"MIN. 15 3/4" MIN. 15 3/4"33"-36"2' - 6" 2" 1' - 5 3/4" 1' - 6 1/4" 2' - 6" 1' - 0" 2' - 6" 6' - 0"3' - 6"4"2' - 10"MIN. 15 3/4" MIN. 15 3/4"33"-36"33"-36"Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.SAA C:\Users\spoole\Documents\21113 Converge NW, Waukee, IA_3&4-Plex One-Story Townhouse_spoolePMDSN.rvt12/2/2021 3:26:29 PMCONVERGE NWTOWNHOUSESWAUKEE, IOWA21113 A-414 TYPE 3B UNIT PLAN SP UNIT PLAN KEYNOTES LABEL REMARKS 1 REFER TO OVERALL BUILDING PLANS FOR SPECIFIC WINDOW TYPE & LOCATION, TYP. 2 WINDOWS TO RECEIVE DRYWALL SILL & RETURNS TO MATCH ADJ. WALL, TYP. 3 INSTALL WINDOW BLINDS, SIZED TO FIT WINDOW, AT ALL WINDOW LOCATIONS; SPECIFIC T.B.D., TYP. 4 REFER TO OVERALL BUILDING PLANS FOR DECK/PATIO SIZE, DETAILS, ETC. 5 COATED WIRE SHELF W/ INTEGRAL HANGING ROD - 12" DEEP 6 (2 LAYERS) COATED WIRE SHELF WITH INTEGRAL HANGING ROD - 12" DEEP; TOP OF LOWER SHELF AND ROD TO BE INSTALLED AT 48" AFF MAXIMUM 7 (5 LAYERS) COATED WIRE SHELF - 16" DEEP; TOP OF 3 LAYERS TO BE INSTALLED BETWEEN 15"-48" AFF 8 UNIT ENTRY DOOR; REFER TO DETAIL #3 ON SHEET G-011 FOR MINIMUM DOOR CLEARANCES 9 REFER TO OVERALL BUILDING PLANS FOR SPECIFIC PATIO DOOR LOCATION 10 MECHANICAL EQUIPMENT SHOWN FOR COORDINATION PURPOSES ONLY; ALL MEP SCOPE IS DESIGN-BUILD BY CONTRACTOR 11 STEEL COUNTERTOP BRACKET - SIZED APPROPRIATELY PER OVERHANG, TYP. 12 36" X 80" CASED OPENING 13 COAT HOOKS INSTALLED @ 66" AFF OVER STAINED WOOD RAIL 14 18" DEEP WOOD BENCH W/ CUBBIES & COAT HOOKS INSTALLED @ 66" AFF OVER STAINED WOOD RAIL 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. DIMENSIONS ARE TO FACE OF FINISH MATERIAL AND CENTER OF DOOR UNLESS OTHERWISE SPECIFIED. 3. MECHANICAL, ELECTRICAL, PLUMPING, FIRE SPRINKLER, FIRE/SMOKE ALARM SCOPE IS TO BE DESIGN/BUILD BY CONTRACTOR. FIXTURES AND EQUIPMENT SHOWN IS PROVIDED FOR COORDINATION PURPOSES ONLY. THE LAYOUT IS CONSIDERED CONCEPTUAL. REFER TO OTHER CONSULTANT & CONTRACTOR DOCUMENTS FOR SPECIFIC DESIGN INFORMATION. 4. ALL INTERIOR WALLS OF UNIT ARE TO BE WALL TYPE 6, UNLESS OTHERWISE SPECIFIED. SEE SHEET A-101 FOR WALL TYPES. 5. ALL CONDUITS, PIPES, WIRING, ROUGH-IN, ETC. SHOULD BE HELD AS TIGHT AS POSSIBLE TO THE ROOF OR FLOOR DECK OR SHOULD BE KEPT WITHIN INTERIOR WALL AND FLOOR/CEILING CAVITIES. NOTHING SHALL BE EXPOSED IN FINISHED SPACES, NOTHING SHALL PREVENT A SMOOTH CONTINUOUS FINISHED WALL OR CEILING AS NOTED ON THE DRAWINGS AND NO PLUMBING RAN IN EXTERIOR WALLS UNLESS PRIOR APPROVAL IS GRANTED BY THE ARCHITECT OR OWNER. PLACEMENT COORDINATION BETWEEN TRADES IS REQUIRED. 6. FLOORING TO BE COMPLETE UNDER RANGE & REFRIGERATOR. 7. ALL APARTMENTS ARE ANSI A-117 CH.10 TYPE B UNITS UNLESS OTHERWISE INDICATED. 8. INSTALL AN EXHAUST FAN IN EACH BATHROOM AS REQUIRED BY CODE. EXTEND EXHAUST TO OUTSIDE AIR CODE REQUIREMENTS. 9. REFER TO ACCESSIBILITY MATRIX FOR ACCESSIBLE, TYPE A, TYPE B, TYPE C & ACCESSIBLE COMMUNICATION UNIT REQUIREMENTS. 10. KITCHEN CABINETRY LAYOUTS ARE CONCEPTUAL ONLY. VERIFY FINAL LAYOUTS WITH OWNER PRIOR TO CONSTRUCTION. 11. INSTALL VERTICAL CONTROL JOINT FOR GYPSUM BOARD WALLS AT THE HEAD OF DOOR JAMBS/OPENINGS (ONE SIDE ONLY) OR AS OTHERWISE NOTED OR WHERE REQUIRED PER STANDARD MATERIAL PRACTICE (IN WALLS GREATER THAN 24') TO REDUCE STRESS CRACKING. 12. PROVIDE ADEQUATE WOOD BLOCKING FOR MILLWORK, FIXTURES, EQUIPMENT, PLUMBING FIXTURES AND ACCESSORIES, ELECTRIC PANELS, ETC. 13. AT ALL UNITS WHERE THE WASHER & DRYER ARE LOCATED IN A DEDICATED CLOSET, PROVIDE A RETURN AIR GRILLE IN THE WALL ABOVE THE DOOR HEADER SIZED TO PROVIDE ADEQUATE VENTILATION FOR PROPER WASHER & DRYER OPERATION. 14. ALL LAUNDRY, UTILITY, & MECH ROOMS SHALL RECEIVE EPOXY PAINT THROUGHOUT THE ENTIRE ROOM. GENERAL UNIT PLAN NOTES Rev. #Issue / RevisionDate330% Set12-03-2021SCALE:1/4" = 1'-0"1 TYPE 3B UNIT FLOOR PLAN SCALE:1/2" = 1'-0"2 UNIT 3B KITCHEN ELEVATION 1 SCALE:1/2" = 1'-0"3 UNIT 3B KITCHEN ELEVATION 2 SCALE:1/2" = 1'-0"4 UNIT 3B BATHROOM ELEVATION SCALE:1/2" = 1'-0"5 UNIT 3B M. BATHROOM ELEVATION TYPE 3B DOOR & FRAME SCHEDULE DOOR NO. ROOM NAME DOOR FRAME HARDWARE REMARKS (ALSO SEE NOTES) UNITTYPE PAIR WIDTH HEIGHT MAT'L TYPE RATING MAT'L CLOSER THLD 001 ENTRY No 3' - 0" 6' - 8" VINYL VINYL Yes Yes ENTRY DOOR 3B 002 BEDROOM No 2' - 10" 6' - 8" WOOD WOOD No No PRIVACY LOCK 3B 003 CLOSET Yes 5' - 0" 6' - 8" WOOD WOOD No No BYPASS, PASSAGE 3B 004 BATH No 2' - 6" 6' - 8" WOOD WOOD No No PRIVACY LOCK 3B 005 BEDROOM No 3' - 0" 6' - 8" WOOD WOOD No No PRIVACY LOCK 3B 006 CLOSET Yes 5' - 0" 6' - 8" WOOD WOOD No No BYPASS, PASSAGE 3B 007 LAUNDRY No 3' - 0" 6' - 8" WOOD WOOD No No PRIVACY LOCK 3B 008 M. BATHROOM No 2' - 10" 6' - 8" WOOD WOOD No No PRIVACY LOCK 3B 010 BEDROOM No 2' - 10" 6' - 8" WOOD WOOD No No PASSAGE 3B 013 MECH. Yes 5' - 0" 6' - 8" WOOD WOOD No No BYPASS, PASSAGE 3B 014 LAUNDRY No 3' - 0" 6' - 8" WOOD WOOD No No PRIVACY LOCK 3B 015 No 16' - 0" 7' - 0" ---- GARAGE DOOR 3B 015.1 GARAGE No 3' - 0" 6' - 8" WOOD WOOD Yes No ENTRY LOCK 3B GARAGE 20 MIN. REF. DW WDLIVING 005 KITCHEN 003 ENTRY 001 BATH 004 CLOSET 002 GARAGE 000 A-415 5 4 3 4 A-415 616' - 6 1/4"4 1/2"9' - 7"6 3/4"19' - 11 1/4"18' - 5" 6 1/2" 3' - 6"19' - 11 1/4"6 3/4"4' - 5 1/2"6 1/2"8' - 8 7/8"6 1/2"7' - 8 7/8"4' - 5 1/2"10' - 9" 5' - 3" 4 1/2" 2' - 0 1/2"6 1/2" 3' - 6"4 1/2"3' - 0"4 1/2"4' - 5 1/2"19' - 3 5/8" 11 123 93 8 5 000 000.1 002 004 001 BEDROOM 013 BEDROOM 016 WIC 014 WIC 017 BATH 018 LAUNDRY 012 MECH. 008 BATH 015 BEDROOM 009 WIC 011 BATH 010 CORRIDOR 007 A-4158 A-415 7 A-415 913' - 4 3/8"4 1/2"5' - 9"4 1/2"3' - 0"6 1/2"5' - 0"4 1/2"5' - 0"4 1/2"12' - 9 7/8"11' - 9 1/4" 4 1/2" 10' - 3 5/8"5' - 1 5/8"4 1/2"12' - 3"4 1/2"3' - 5 7/8"4 1/2"6' - 1"4 1/2"5' - 3 7/8"4 1/2"12' - 9 7/8"8' - 6 7/8" 4 1/2" 5' - 11 3/4" 4 1/2" 7' - 1 3/4" 8' - 6 7/8" 4 1/2" 4' - 1 1/8" 6 1/2" 8' - 10 3/8" 12' - 11 7/8" 4 1/2" 5' - 0" 6 1/2" 3' - 6 1/2" 6 5 6 5 7 6 5 5 10 1 2 3 1 2 3 016013 015 018 012 009 011 008 12 12 2' - 6"1' - 6"3' - 0"2' - 0"2' - 0"3' - 6"1' - 0" 3" 2' - 0"3' - 0"7' - 0"2' - 0" 2" 1' - 6" 2' - 6" 1' - 3" 2" 2' - 0" 1' - 0 1/2"3' - 0"1' - 6"2' - 6"7' - 0"1' - 0" 2" 2' - 6" 2' - 6" 1' - 0" 1' - 0" 2" 1' - 0"3' - 0"2' - 9" 1 3/4" 3' - 0" 1 3/4" 2' - 0" 2" 3' - 0"2' - 9"3' - 3 1/2"6' - 0"1' - 0"7' - 0"3' - 0"1' - 6"2' - 6"4"2' - 10"3' - 6"2' - 9" 1' - 0" 2' - 9" 3' - 3" 2' - 6" 6' - 6"3' - 6"4"2' - 10"1 1/2" 3' - 3" 1 1/2"2' - 10"4"3' - 6"Sheet No. Sheet Title Proj. No.Proj. Mgr.This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C.SAA C:\Users\spoole\Documents\21113 Converge NW, Waukee, IA_4-Plex Two-Story Townhouse_spoolePMDSN.rvt12/2/2021 3:19:20 PMCONVERGE NWTOWNHOUSESWAUKEE, IA21113 A-415 TYPE 3C UNIT PLAN SP SCALE:1/4" = 1'-0"1 TYPE 3C UNIT FIRST FLOOR PLAN SCALE:1/4" = 1'-0"2 TYPE 3C UNIT SECOND FLOOR PLAN SCALE:1/2" = 1'-0"3 TYPE 3C - KITCHEN SCALE:1/2" = 1'-0"4 TYPE 3C - KITCHEN 2 SCALE:1/2" = 1'-0"5 TYPE 3C - KITCHEN 3 SCALE:1/2" = 1'-0"8 TYPE 3C - BATHROOM SCALE:1/2" = 1'-0"7 TYPE 3C - BATHROOM 3 SCALE:1/2" = 1'-0"9 TYPE 3C - BATHROOM 2 SCALE:1/2" = 1'-0"6 TYPE 3C - 1/2 BATHROOM Rev. #Issue / RevisionDate330% Set12-03-2021TYPE 3C DOOR & FRAME SCHEDULE DOOR NO.ROOM NAME DOOR FRAME HARDWARE REMARKS (ALSO SEE NOTES)UNITTYPE PAIR WIDTH HEIGHT MAT'L TYPE RATING MAT'L CLOSER THLD 000 OHD No 16' - 0" 7' - 0" -- -- GARAGE DOOR 3C 000.1 GARAGE P2 No 3' - 0" 6' - 8" WOOD 2 WOOD KEYED ENTRY 3C 001 LIVING P3 No 3' - 0" 6' - 8" VINYL 1 VINYL Yes Yes ENTRY DOOR 3C 002 CLOSET P2 No 2' - 6" 6' - 8" WOOD 2 WOOD No No PASSAGE 3C 004 LIVING P2 No 2' - 6" 6' - 8" WOOD 2 WOOD No No PRIVACY LOCK 3C 009 BEDROOM P2 No 3' - 0" 6' - 8" WOOD 2 WOOD PRIVACY LOCK 3C 011 WIC P2 No 2' - 6" 6' - 8" WOOD 2 WOOD No No PRIVACY LOCK 3C 012 LAUNDRY P2 No 3' - 0" 6' - 8" WOOD 2 WOOD PASSAGE 3C 013 BEDROOM P2 No 2' - 6" 6' - 8" WOOD 2 WOOD PRIVACY LOCK 3C 015 BATH P2 No 2' - 6" 6' - 8" WOOD 2 WOOD PRIVACY LOCK 3C 016 BEDROOM P2 No 2' - 6" 6' - 8" WOOD 2 WOOD PRIVACY LOCK 3C 018 BATH P2 No 2' - 6" 6' - 8" WOOD 2 WOOD No No PRIVACY LOCK 3C GARAGE 20 MIN. UNIT PLAN KEYNOTES LABEL REMARKS 1 REFER TO OVERALL BUILDING PLANS FOR SPECIFIC WINDOW TYPE & LOCATION, TYP. 2 WINDOWS TO RECEIVE DRYWALL SILL & RETURNS TO MATCH ADJ. WALL, TYP. 3 INSTALL WINDOW BLINDS, SIZED TO FIT WINDOW, AT ALL WINDOW LOCATIONS; SPECIFIC T.B.D., TYP. 4 REFER TO OVERALL BUILDING PLANS FOR DECK/PATIO SIZE, DETAILS, ETC. 5 COATED WIRE SHELF W/ INTEGRAL HANGING ROD - 12" DEEP 6 (2 LAYERS) COATED WIRE SHELF WITH INTEGRAL HANGING ROD - 12" DEEP; TOP OF LOWER SHELF AND ROD TO BE INSTALLED AT 48" AFF MAXIMUM 7 (5 LAYERS) COATED WIRE SHELF - 16" DEEP; TOP OF 3 LAYERS TO BE INSTALLED BETWEEN 15"-48" AFF 8 UNIT ENTRY DOOR; REFER TO DETAIL #3 ON SHEET G-011 FOR MINIMUM DOOR CLEARANCES 9 REFER TO OVERALL BUILDING PLANS FOR SPECIFIC PATIO DOOR LOCATION 10 MECHANICAL EQUIPMENT SHOWN FOR COORDINATION PURPOSES ONLY; ALL MEP SCOPE IS DESIGN-BUILD BY CONTRACTOR 11 STEEL COUNTERTOP BRACKET - SIZED APPROPRIATELY PER OVERHANG, TYP. 12 36" X 80" CASED OPENING 17' - 4" 1' - 8"14' - 0"1' - 8"13' - 4"A-502 2 A-502 4 A-5023 A-502 3 SIM.5' - 10 3/4"3' - 0 3/8" 3' - 4" 3' - 4" 3' - 4" 3' - 0 3/8"1' - 4" 3' - 4" 8' - 8" PAVING 0" T.O. BRICK 6' - 8" COP-1 BRK METAL PANEL W/ METAL FRAME - FINISH BLACK SUBMERGE T.S. COLUMN 48" INTO FOOTING 6" CONCRETE FILLED GALV STL PIPE - PAINT BLACK PINS BOTH DOORS - SEE DTL PAVING 0" T.O. BRICK 6' - 8" BRK COP-1 6" CONCRETE FILLED GALV STL PIPE - PAINT BLACK PAVING 0" T.O. BRICK 6' - 8" COP-1 BRK GRADE BRICK OVER CMU W/ INTERGAL WATER REPELLANT CMU 6" THICK 1/4" SLOPE MAX. CONCRETE DUMPSTER PAD TREATED 2X8 WOOD GUARD RAIL ANCHOR TO BRICKWALL AT HEIGHT OF DUMPSTER PINS PIPE BOLLARD FOUNDATION PRE-FINISHED METAL PANEL OVER 3/4" TREATED PLYWOOD ON STEEL FRAME GATES T.S. 3x2x3/16 FRAME & CROSS BRACE @ GATE DOORS PREFINISHED SHT MTL CAP OVER EPDM OVER TREATED WOOD BLOCKING T.S. 6x6x1/4 CORNER POSTS @ GATE DOORS 3' - 6" 8" 6' - 8" 1' - 8" SLOPE TOP (2) #4 CONT. TO TIE DOWELS TO (4) CONT. #5 (2T & 2B)#3 TIES @ 4'-0" MAX. #5 DOWELS x 5'-0" (PROJ. 3'-0") @ 32" O.C. #5 VERT. @ 32" O.C. HORIZ. REINF: LADDER TYPE @ 16" O.C. 6X6X1//4 GALV. STEEL TUBE - PAINT 3/4" DIA. STEEL HINGE PIN (WELDED TO STEEL TUBE) 3/4" DIA. STEEL HINGE SLEEVE (BOLTED TO DOOR) METAL PANEL W/ METAL FRAME - FINISH BLACK 5/8" DIA. BAR SIDE FRONT 1/4" PLATE 5/8" I.D. RING 3/8" DIA. HOLE 5/8" I.D. SPRING 5/8" I.D. RING 3/8" DIA. HOLE 2"3' - 0"5" 2"4 3/4" 1' - 0"4 3/4"3 3/4"6 1/2"1 3/4"SAA JOB #: This drawing has been prepared by the Architect, or under the Architect's direct supervision. This drawing is provided as an instrument of service by the Designer / Architect and is intended for use on this project only. Any reproduction, use, or disclosure of information contained herein without the prior written consent of the Architect is strictly prohibited. (C) Copyright 2021 by Simonson & Associates Architects, L.L.C. 24"x36" SHEET (FULL SIZE) -SCALE IS AS NOTED. 12"x18" SHEET (HALF SIZE) -SCALE IS ONE-HALF OF WHAT IS NOTED OTHER SHEET SIZES NOT TO SCALE 21113 WAUKEE CROSSING WAUKEE, IA 10/12/21 1.REFER TO ADDITIONAL NOTES & REQUIREMENTS ON ALL OTHER DOCUMENTS & OTHER DISCIPLINES DOCUMENTS. 2.ALL HORIZONTAL TRANSITIONS BETWEEN DIFFERENT MATERIALS SHALL BE FLASHED CONTINUOUS FROM UP BEHIND TO UNDER UPPER MATERIAL & EXTEND OVER TO EXTERIOR FACE OF LOWER MATERIAL. SOFT JOINTS REQUIRED BETWEEN DISSIMILAR MATERIALS. 3.INSTALL VERTICAL EXPANSION JOINTS MINIMAL AT COLUMN/GRID LINE AND & AT THE HEAD OF DOOR JAMBS/OPENING OR AS OTHERWISE NOTED OR WHERE REQUIRED PER STANDARD MATERIAL PRACTICES TO REDUCE STRESS CRACKING. NO CONTROL JOINTS/ EXPANSION JOINTS AT MAIN STRUCTURAL BEARING, KEEP AWAY 2'-6" MIN. 4.CAULK & SEAL ALL TRANSITION-CONTROL-EXPANSION AT ALL EXTERIOR MATERIALS. ALL SEALANTS SHOULD BE COLOR-MATCHED TO ADJACENT MATERIAL. 5.INSULATE AND SEAL TO ENSURE ADEQUATE AIR INFILTRATION BARRIER AROUND ALL EXTERIOR PENETRATIONS TO PREVENT WATER AND SPRINKLER PIPE FREEZING. 6. ALL METAL EXPOSED TO EXTERIOR OR EXPOSED TO MOISTURE SHALL BE GALVANIZED 7. STAINLESS STEEL CLIPS ARE REQUIRED FOR ANY MASONRY LARGER THAN 8x16 FACE SIZE GENERAL DETAIL NOTES: NORTH SCALE:1/4" = 1'-0"1 TRASH ENCLOSURE PLAN SCALE:1/4" = 1'-0"2 TRASH ENCLOSURE FRONT ELEVATION SCALE:1/4" = 1'-0"3 TRASH ENCLOSURE SIDE ELEVATION SCALE:1/4" = 1'-0"4 TRASH ELNCOSURE BACK ELEVATION SCALE:1/4" = 1'-0"5 TRASH CROSS SECTION SCALE:1 1/2" = 1'-0"6 TRASH HINGE SCALE:3/4" = 1'-0"7 TRASH PIN