Loading...
HomeMy WebLinkAbout2022-04-04 J19 Vintage Estates of Waukee_Site Plan AGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: April 4, 2022 AGENDA ITEM: Consideration of approval of a resolution approving a site plan for Vintage Estates of Waukee FORMAT: Resolution SYNOPSIS INCLUDING PRO & CON: Ewing Properties, requests approval of a site plan for a detached townhome development. The property is 7.90-acres in area and is located south of SE Tallgrass Lane and west of SE Parkview Crossing Drive. The site plan includes 29 detached townhomes and one (1) clubhouse. In addition, to the clubhouse, the site will include a pool and sport courts for residents use. Access to the site will be provided from SE Esker Ridge Drive. The required amount of parking is being provided across the site. All utilities and streets internal to the site will be privately owned and maintained. The applicant has provided elevations for the proposed building on the site. The design and materials are consistent with the Site Plan Ordinance. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning Commission reviewed this project at the December 14, 2021 Commission Meeting and recommended approval subject to remaining staff comments: Approval of a Final Plat for Vintage Estates of Waukee Planning Coordinator, Andy Kass, introduced the request for approval of a preliminary plat, final plat, and site plan for a villa style townhome development as submitted by the applicant, Ewing Properties. The property is generally located north of SE Esker Ridge Drive and west of SE Parkview Crossing Drive, containing approximately 11- acres. Mr. Kass advised that the development would include the construction of 29 detached townhome units and one clubhouse that will be owner occupied, but parceled as one lot to be operated as a Cooperative for maintenance of the common areas. The maximum size of the villas is shown to be 2,552 square feet and the clubhouse is shown to be 6.507 square feet in size and contain an outdoor pool. A Planned Development provides specific provisions for the size and appearance of the product. Access to the property is shown off of SE Esker Ridge Drive to the privately owned and maintained SE Vintage Lane for final access to the units and clubhouse. Public utilities will be extended to the property, all utilities internal to the site will be privately owned and maintained. A 25 foot landscape buffer is required along all sides of the development, and a fee has been proposed in lieu of parkland dedication. J19 Lot 2 which is zoned K-OF (Kettlestone Office District) will not contain any of the mentioned project. Development on this lot is not proposed at this time. Staff recommends approval of the preliminary plat, final plat, and site plan subject to any remaining staff comments and review of the legal documents.  Commissioner Hoifeldt moved to approve the Preliminary Plat for Vintage Estates of Waukee subject to any remaining staff comments and review of the legal documents. The motion was seconded by Commissioner Ward. Ayes: Streit, Broderick, Hoifeldt, Koshy, Ward, and Gerlitz. Nays: none. Motion Carried.  Commissioner Hoifeldt moved to approve the Final Plat for Vintage Estates of Waukee subject to any remaining staff comments and review of the legal documents. The motion was seconded by Commissioner Gerlitz. Ayes: Streit, Broderick, Hoifeldt, Koshy, Ward, and Gerlitz. Nays: none. Motion Carried. Commissioner Hoifeldt moved to approve the Final Plat for Vintage Estates of Waukee subject to any remaining staff comments and review of the legal documents. The motion was seconded by Commissioner Broderick. Ayes: Streit, Broderick, Hoifeldt, Koshy, Ward, and Gerlitz. Nays: none. Motion Carried. STAFF REVIEW AND COMMENT: Staff recommends approval of the site plan subject to remaining staff comments. RECOMMENDATION: Approve the resolution subject to remaining staff comments. ATTACHMENTS: I. Proposed Resolution II. Staff Report III. Site Plan & Elevations PREPARED BY: Andy Kass, Community Development Director REVIEWED BY: THE CITY OF WAUKEE, IOWA RESOLUTION 2022- APPROVING THE SITE PLAN FOR VINTAGE ESTATES OF WAUKEE (700 SE ESKER RIDGE DRIVE) IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Site Plan for Vintage Estates of Waukee, subject to remaining staff comments on December 14, 2021; AND, WHEREAS, the Site Plan for Vintage Estates of Waukee is in general conformance with §160 – Site and Building Development Standards Ordinance of the Waukee Municipal Code; AND, WHEREAS, the Site Plan for Vintage Estates of Waukee is in general conformance with §161 – Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND, NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 4th day of April, 2022 that the Site Plan for Vintage Estates of Waukee is approved subject to remaining staff comments. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Anna Bergman Pierce R. Charles Bottenberg Chris Crone Larry R. Lyon Ben Sinclair PLANNING AND ZONING COMMISSION STAFF REPORT PROJECT: Vintage Estates of Waukee – Preliminary Plat, Final Plat, & Site Plan PREPARED BY: Andy Kass, AICP, Planning Coordinator REPORT DATE: December 10, 2021 MEETING DATE: December 14, 2021 GENERAL INFORMATION Applicant: Ewing Properties Owner: E & J, LLC Owner’s Representative: Jason Ledden, P.E. – Snyder & Associates Request: The applicant is requesting approval of a preliminary plat, final plat, and site plan for a villa style development. Location and Size: Property is generally located north of SE Esker Ridge Drive and west of SE Parkview Crossing Drive, containing approximately 11-acres. AREA MAP ABOVE: Aerial of subject property (outlined in BLUE) in relation to the surrounding area. December 10, 2021 2 of 4 LAND USES AND ZONING Location Existing Land Use Comprehensive Plan Current Zoning Property in Question Vacant - Undeveloped Office R-4 (Row Dwelling & Townhomes District) / PD-1 (Planned Development Overlay) & K-OF (Kettlestone Office) North Kettlestone Heights Neighborhood Medium Density Residential R-2 (One & Two Family Residential District) / PD-1 (Planned Development Overlay) South Vacant - Undeveloped Retail Community K-RC (Kettlestone Retail Community) East Kettleview Office Office K-OF (Kettlestone Office) & K-MU (Kettlestone Mixed-Use) West Kettlestone Ridge Neighborhood Single Family Residential R-2 (One & Two Family Residential District) HISTORY The subject property is located north of SE Esker Ridge Drive and west of SE Parkview Crossing Drive. The property is approximately 11-acres in area and was the subject of a rezoning in summer 2021. PROJECT DESCRIPTION The project involves the construction of 29 detached villa style townhome units and one (1) clubhouse. The maximum size of the villas is shown to be 2,552 square feet in area. The clubhouse is shown to be 6,507 square feet in area and will have an exterior pool. The project is proposed to be developed over the course of one phase. All units will be owner-occupied. The units will be platted on one lot. Trash and recycling service will be provided to each unit. As part of the rezoning process a planned development overlay (PD) was approved to allow for the development. The PD included some specific provisions that the developer will be required to comply with. The specific provisions are as follows:  Minimum two car garage;  Minimum of 1,350 square feet of floor area per unit;  No more than two adjacent units can share the same building elevation; and  Prohibition of vinyl siding December 10, 2021 3 of 4 The site plan demonstrates that the proposed units will meet or exceed the minimum bulk regulations of the R-4/PD-1 zoning district. Table 1 below summarizes the bulk regulations that are applicable to the proposed development. Table 1: Bulk Regulations for the R-4/PD-1 District Category R-4/PD-1 (minimum) Front Yard Setback 30 feet (perimeter) 22-feet (internal w/out sidewalk) 25-feet Internal w/ a sidewalk) Rear Yard Setback 30 feet Side Yard Setback 10 feet Maximum Density 4 units/acre ACCESS AND PARKING Access to the property is shown to be provided from SE Esker Ridge Drive. SE Vintage Lane is shown to be a loop street and will be a privately owned and maintained street. SE Vintage Lane will have streetlights. The street lights will be owned and maintained by the owners cooperative. A five-foot sidewalk will be provided along one side of SE Vintage Lane. In addition, the applicant will install 5- foot sidewalks along SE Esker Ridge Drive and SE Tallgrass Lane. A total of 64 parking spaces are required for the overall development. The site plan indicates 124 parking spaces will be provided across the site. This parking count includes two garage spaces and two driveway spaces provided with each unit. UTILITIES Sanitary sewer and water services were extended to the property as part of the overall Shops at Kettlestone North improvements. Extensions of private sewer and water main will be installed as part of this project. All utilities will be privately owned and maintained. Stormwater detention will be provided for in a regional detention basin to the east. The regional basin is owned and maintained by the City of Waukee. LANDSCAPING & OPEN SPACE The R-4 zoning district does not require a specific open space percentage; however, it does require a minimum of two trees per unit. In addition, the applicant will be required to provide a 25-foot land scape buffer along all sides of the project. The landscape plan demonstrates compliance with the landscape and open space ordinance. PARKLAND DEDICATION A total of 0.42-acres of parkland dedication is required. The applicant has proposed to satisfy this requirement with a fee in lieu of land dedication. ELEVATIONS Elevations of the available units have been provided by the applicant. Proposed materials include hardboard siding, asphalt shingles, stucco, and brick or stone. LOTS The preliminary plat and final plat identify two (2) lots to be platted. Lot 1 is 7.90-acres in area and is where the proposed units will be constructed. Lot 2 is 3.03-acres in area and is not proposed to be developed at this time. Lot 2 is zoned K-OF (Kettlestone Office District). All proposed lots meet the minimum requirements of the Zoning Ordinance. December 10, 2021 4 of 4 STAFF RECOMMENDATION The site plan is in general conformance with the Zoning Ordinance, Subdivision Ordinance, Site Plan Ordinance, and Comprehensive Plan. Staff recommends approval of the preliminary plat, final plat, and site plan subject to remaining staff comments and review of the legal documents. SE ESKER RIDGE DR SE TALLGRAS S L A N E GR A N D P R A I R I E P A R K W A Y SE P A R K V I E W CR O S S I N G D R I V E SE ASHWORTH R O A D INT E R S T A T E 8 0 SE UNIVERSITY AVE PRELIMINARY PLAT AND SITE PLANS FOR VINTAGE ESTATES OF WAUKEE CITY OF WAUKEE, DALLAS COUNTY, IOWA VICINITY MAP PROJECT LOCATION NOT TO SCALE OWNER E&J, LLC 2521 WASHINGTON STREET PELLA, IOWA 50219 CONTACT: JEFF EWING PHONE: (641) 628-1077 EMAIL: jeff@ewingprop.com DEVELOPER EWING PROPERTIES 2521 WASHINGTON STREET PELLA, IOWA 50219 CONTACT: RAY BISBEE PHONE: (641) 780-3408 EMAIL: ray@ewingprop.com ENGINEER SNYDER & ASSOCIATES, INC 2727 SW SNYDER BLVD ANKENY, IOWA 50023 PHONE: (515) 964-2020 PROJECT MANAGER: JASON LEDDEN, PE ERIN GRIFFIN, PLS BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m JA L RM B LB W 09 - 2 8 - 2 0 2 1 10 0 0 ' 12 1 . 0 4 7 6 C1 0 0 121.0476 C100 VI N T A G E E S T A T E S O F W A U K E E TI T L E S H E E T WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 10 / 2 6 / 2 1 11 / 1 1 / 2 1 12 / 0 9 / 2 1 03 / 3 0 / 2 2 RM B RM B LM W LM W 2345 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 1 \ 1 2 1 . 0 4 7 6 . 0 1 \ C A D D \ S P _ 1 2 1 0 4 7 6 _ P L A N . d w g LO R E N A W A S I O N , TI T L E S H E E T , 20 2 2 / 0 3 / 3 0 , 1: 5 3 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) I hereby certify that this engineering document was prepared by me or under my direct personal supervision and that I am a duly licensed Professional Engineer under the laws of the State of Iowa. Jason A. Ledden, P.E.Date License Number P24117 My License Renewal Date is December 31, 2022 Pages or sheets covered by this seal: JASON A. LEDDEN P24117 D P R O F E L NS E ICE IONAL EN G I N E ER AIOW SS SHEETS C100-C503 Index of Sheets Sheet #Sheet Title C100 TITLE SHEET C101 PROJECT INFORMATION C200 HYDRANT COVERAGE PLAN C300 DIMENSION PLAN C400 UTILITY PLAN C401 STORM SEWER PLAN C500 OVERALL GRADING PLAN C501 DETAILED GRADING PLAN C502 DETAILED GRADING PLAN C503 EROSION CONTROL PLAN C504 INTERSECTION AND SIDEWALK DETAILS C600 PLANTING PLAN PROPERTY DESCRIPTION OUTLOT 'X', THE SHOPS AT KETTLESTONE NORTH PLAT 4, AN OFFICIAL PLAT NOW INCLUDED IN AND FORMING A PART OF THE CITY OF WAUKEE, DALLAS COUNTY, IOWA. ZONING LOT 1 R-4/PD-1(BK 2021, PG 27620): ROW DWELLING & TOWNHOME DWELLING DISTRICT/VINTAGE ESTATES PUD LOT 2 K-OF: KETTLESTONE OFFICE DISTRICT BULK REGULATIONS LOT 1 FRONT YARD SETBACK = 30' REAR YARD SETBACK = 30' SIDE YARD SETBACK = 10' MAXIMUM DENSITY = 4 UNITS/ACRE MAXIMUM HEIGHT = 40' MINIMUM FLOOR AREA = 1,350 SF LOT 2 FRONT YARD SETBACK = NONE 20' FOR ACCESSORY STRUCTURES REAR YARD SETBACK = NONE, UNLESS ADJACENT TO SINGLE FAMILY, THEN 50' 5' FOR ACCESSORY STRUCTURES SIDE YARD SETBACK = SAME AS REAR YARD MINIMUM BUILDING SEPARATION = 25' MAXIMUM HEIGHT = 8 STORIES 1 STORY FOR ACCESSORY STRUCTURES MINIMUM HEIGHT: UNDER 15,000 SF = 1 STORY, OVER 15,000 SF = 2 STORY FLOOR AREA RATIO = 0.35 PARKING REQUIREMENTS 2 SPACES PER 1 UNITS 29 UNITS X 2 = 58 SPACES REQUIRED 2 SPACES IN GARAGE AND 2 SPACES IN DRIVEWAY PER UNIT = 116 SPACES VISITOR PARKING SPACE REQUIREMENTS = 1 SPACE PER 5 UNITS 29 UNITS/ 5 UNITS X 1 SPACE = 6 SPACES REQUIRED 8 SPACES PROVIDED INCLUDING 1 HANDICAP STALL TOTAL SPACES PROVIDED = 124 SPACES PROVIDED INCLUDING 1 HANDICAP STALL AREA 10.93 ACRES (475,765 S.F.) BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m JA L RM B LB W 09 - 2 8 - 2 0 2 1 1' 12 1 . 0 4 7 6 C1 0 1 121.0476 C101 VI N T A G E E S T A T E S O F W A U K E E PR O J E C T I N F O R M A T I O N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 10 / 2 6 / 2 1 11 / 1 1 / 2 1 12 / 0 9 / 2 1 03 / 3 0 / 2 2 RM B RM B LM W LM W 2345 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 1 \ 1 2 1 . 0 4 7 6 . 0 1 \ C A D D \ S P _ 1 2 1 0 4 7 6 _ P L A N . d w g LO R E N A W A S I O N , PR O J E C T I N F O R M A T I O N , 20 2 2 / 0 3 / 3 0 , 1: 5 3 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) UTILITY QUALITY SERVICE LEVELS QUALITY LEVELS OF UTILITIES ARE SHOWN IN THE PARENTHESES WITH THE UTILITY TYPE AND WHEN APPLICABLE, SIZE. THE QUALITY LEVELS ARE BASED ON THE CI / ASCE 38-02 STANDARD. QUALITY LEVEL (D) INFORMATION IS DERIVED FROM EXISTING UTILITY RECORDS OR ORAL RECOLLECTIONS. QUALITY LEVEL (C) INFORMATION IS OBTAINED BY SURVEYING AND PLOTTING VISIBLE ABOVE-GROUND UTILITY FEATURES AND USING PROFESSIONAL JUDGMENT IN CORRELATING THIS INFORMATION WITH QUALITY D INFORMATION. QUALITY LEVEL (B) INFORMATION IS OBTAINED THROUGH THE APPLICATION OF APPROPRIATE SURFACE GEOPHYSICAL METHODS TO DETERMINE THE EXISTENCE AND APPROXIMATE HORIZONTAL POSITION OF SUBSURFACE UTILITIES. QUALITY LEVEL (A) IS HORIZONTAL AND VERTICAL POSITION OF UNDERGROUND UTILITIES OBTAINED BY ACTUAL EXPOSURE OR VERIFICATION OF PREVIOUSLY EXPOSED SUBSURFACE UTILITIES, AS WELL AS THE TYPE, SIZE, CONDITION, MATERIAL, AND OTHER CHARACTERISTICS. UTILITY WARNING THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR RECORDS OBTAINED. THE SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES OR SUBSURFACE FEATURES SHOWN COMPRISE ALL SUCH ITEMS IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UTILITIES OR SUBSURFACE FEATURES SHOWN ARE IN THE EXACT LOCATION INDICATED EXCEPT WHERE NOTED AS QUALITY LEVEL A. FEATURES EXISTING PROPOSED Spot Elevation Contour Elevation Fence (Barbed, Field, Hog) Fence (Chain Link) Fence (Wood) Fence (Silt) Tree Line Tree Stump Deciduous Tree \\ Shrub Coniferous Tree \\ Shrub Communication Overhead Communication Fiber Optic Underground Electric Overhead Electric Gas Main with Size High Pressure Gas Main with Size Water Main with Size Sanitary Sewer with Size Duct Bank Test Hole Location for SUE w/ID (*) Denotes the survey quality service level for utilities Sanitary Manhole Storm Sewer with Size Storm Manhole Single Storm Sewer Intake Double Storm Sewer Intake Fire Hydrant Fire Hydrant on Building Water Main Valve Water Service Valve Well Utility Pole Guy Anchor Utility Pole with Light Utility Pole with Transformer Street Light Yard Light Electric Box Electric Transformer Traffic Sign Communication Pedestal Communication Manhole Communication Handhole Fiber Optic Manhole Fiber Optic Handhole Gas Valve Gas Manhole Gas Apparatus Fence Post or Guard Post Underground Storage Tank Above Ground Storage Tank Sign Satellite Dish Mailbox Sprinkler Head Irrigation Control Valve LEGEND ○ 1 2 2 5 X 1225.25 ● X 1 2 2 5 1225.25 FEATURES FOUND SET Section Corner 1/2" Rebar, Cap # 11579 (Unless Otherwise Noted) ROW Marker ROW Rail Control Point Bench Mark Platted Distance P Measured Bearing & Distance M Recorded As R Deed Distance D Calculated Distance C Minimum Protection Elevation MPE Centerline Section Line 1/4 Section Line 1/4 1/4 Section Line Easement Line UTILITY CONTACT INFORMATION UTILITY CONTACT FOR MAPPING INFORMATION SHOWN AS RECEIVED FROM THE IOWA ONE CALL DESIGN REQUEST SYSTEM, TICKET NUMBER 552105375. CO1-COMMUNICATION CENTURY LINK SADIE HULL 918-547-0147 SADIE.HULL@LUMEN.COM UE1-UNDERGROUND ELECTRIC MIDAMERICAN ENERGY JAMIE NEER 515-252-6972 MECDSMDESIGNLOCATES@MIDAMERICAN.COM W1-WATER MAIN WAUKEE, CITY OF S1-SANITARY SEWER TIM ROYER ST1- STORM SEWER 515-978-7920 G1-NATURAL GAS TROYER@WAUKEE.ORG CONTROL POINTS IOWA SOUTH STATE PLANE COORDINATE SYSTEM NAD83(2011)(EPOCH 2010.00) IARTN DERIVED - US SURVEY FEET CP100 N=577071.89 E=1542829.15 Z=1045.20 SET CUT "X" ON TOP CURB AT DOUBLE BACK OF CURB INTAKE LOCATED SOUTH SIDE SE ESKER RIDGE DR., +-60' WEST OF CENTERLINE SE PARKVIEW CROSSING DR. (AS SHOWN ON SURVEY) CP101 N=577090.55 E=1542487.89 Z=1048.78 SET CUT "X" ON TOP CURB, SOUTH SIDE SE ESKER RIDGE DR., LOCATED AT MID RAD ACROSS FROM HYDRANT. (AS SHOWN ON SURVEY) CP102 N=576839.19 E=1542140.13 Z=1046.85 SET CUT "X" TOP CURB, WEST EDGE SE WILLOWBROOK DR., LOCATED +-15' NW OF CENTERLINE CENTERLINE AT MIDRAD. (AS SHOWN ON SURVEY) CP103 N=577711.78 E=1542175.21 Z=1050.29 SET CUT "X" TOP CURB, SOUTH SIDE SE TALLGRASS LN. LOCATED AT NE CORNER PROPERTY 600 SE TALLGRASS LN. (AS SHOWN ON SURVEY) CP104 N=577888.79 E=1542929.93 Z=1032.58 SET CUT "X" TOP CURB, NE QUAD TALLGRASS LN. AND SE PARKVIEW CROSSING DR. AT STORM CLEANOUT. (AS SHOWN ON SURVEY) BENCHMARKS NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88 - GEOID12A) IARTN DERIVED - US SURVEY FEET BM500 ELEV=1048.47 NE BURY BOLT ON HYDRANT, LOCATED AT 1ST HYDRANT WEST OF SE PARKVIEW CROSSING DR., NORTH SIDE OF ESKER DR. (AS SHOWN ON SURVEY) BM501 ELEV=1035.92 SW BURY BOLT ON HYDRANT, LOCATED 1ST HYDRANT SOUTH OF SE TALLGRASS LN., WEST SIDE OF SE PARKVIEW CROSSING DR (AS SHOWN ON SURVEY) DATE OF SURVEY AUGUST 27TH, 2021 POLLUTION PREVENTION NOTES A.POLLUTION PREVENTION AND EROSION PROTECTION 1.CODE COMPLIANCE: THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL POTENTIAL POLLUTION AND SOIL EROSION CONTROL REQUIREMENTS OF THE IOWA CODE, THE IOWA DEPARTMENT OF NATURAL RESOURCES (IDNR) NPDES PERMIT, THE U.S. CLEAN WATER ACT AND ANY LOCAL ORDINANCES. THE CONTRACTOR SHALL TAKE ALL NECESSARY STEPS TO PROTECT AGAINST EROSION AND POLLUTION FROM THIS PROJECT SITE AND ALL OFF-SITE BORROW OR DEPOSIT AREAS DURING PERFORMANCE OR AS A RESULT OF PERFORMANCE. 2.DAMAGE CLAIMS: THE CONTRACTOR WILL HOLD THE OWNER AND ARCHITECT / ENGINEER HARMLESS FROM ANY AND ALL CLAIMS OF ANY TYPE WHATSOEVER RESULTING FROM DAMAGES TO ADJOINING PUBLIC OR PRIVATE PROPERTY, INCLUDING REASONABLE ATTORNEY FEES INCURRED TO OWNER. FURTHER, IF THE CONTRACTOR FAILS TO TAKE NECESSARY STEPS TO PROMPTLY REMOVE EARTH SEDIMENTATION OR DEBRIS WHICH COMES ONTO ADJOINING PUBLIC OR PRIVATE PROPERTY, THE OWNER MAY, BUT NEED NOT, REMOVE SUCH ITEMS AND DEDUCT THE COST THEREOF FROM AMOUNTS DUE TO THE CONTRACTOR. B.STORM WATER DISCHARGE PERMIT 1.THIS PROJECT REQUIRES COVERAGE UNDER THE NPDES GENERAL PERMIT NO. 2 FOR STORM WATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITIES FROM THE IDNR, AS REQUIRED BY THE ENVIRONMENTAL PROTECTION AGENCY (EPA). THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS ARE RESPONSIBLE FOR COMPLIANCE WITH AND FULFILLMENT OF ALL REQUIREMENTS OF THE NPDES GENERAL PERMIT NO. 2 AS SPECIFIED IN THE CONTRACT DOCUMENTS. 2.ALL DOCUMENTS RELATED TO THE STORM WATER DISCHARGE PERMIT, INCLUDING, BUT NOT LIMITED TO, THE NOTICE OF INTENT, PROOF OF PUBLICATIONS, DISCHARGE AUTHORIZATION LETTER, CURRENT SWPPP, SITE INSPECTION LOG, AND OTHER ITEMS, SHALL BE KEPT ON SITE AT ALL TIMES AND MUST BE PRESENTED TO ANY JURISDICTIONAL AGENCIES UPON REQUEST. FAILURE TO COMPLY WITH THE NPDES PERMIT REQUIREMENTS IS A VIOLATION OF THE CLEAN WATER ACT AND THE CODE OF IOWA. 3.A "NOTICE OF DISCONTINUATION" MUST BE FILED WITH THE IDNR UPON FINAL STABILIZATION OF THE DISTURBED SITE AND REMOVAL OF ALL TEMPORARY EROSION CONTROL MEASURES. ALL PLANS, INSPECTION REPORTS, AND OTHER DOCUMENTS MUST BE RETAINED FOR A PERIOD OF THREE YEARS AFTER PROJECT COMPLETION. THE CONTRACTOR SHALL RETAIN A RECORD COPY AND PROVIDE THE ORIGINAL DOCUMENTS TO THE OWNER UPON PROJECT ACCEPTANCE AND/OR SUBMITTAL OF THE NOTICE OF DISCONTINUATION. C.POLLUTION PREVENTION PLAN 1.THE STORM WATER POLLUTION PREVENTION PLAN (SWPPP) IS A SEPARATE DOCUMENT IN ADDITION TO THESE PLAN DRAWINGS. THE CONTRACTOR SHOULD REFER TO THE SWPPP FOR ADDITIONAL REQUIREMENTS AND MODIFICATIONS TO THE POLLUTION PREVENTION PLAN MADE DURING CONSTRUCTION. 2.THE SWPPP ILLUSTRATES GENERAL MEASURES AND BEST MANAGEMENT PRACTICES (BMP) FOR COMPLIANCE WITH THE PROJECT'S NPDES PERMIT COVERAGE. ALL BMP'S AND EROSION CONTROL MEASURES REQUIRED AS A RESULT OF CONSTRUCTION ACTIVITIES ARE THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY, NOTE AND IMPLEMENT. ADDITIONAL BMP'S FROM THOSE SHOWN ON THE PLAN MAY BE REQUIRED. 3.THE SWPPP AND SITE MAP SHOULD BE EXPEDITIOUSLY REVISED TO REFLECT CONSTRUCTION PROGRESS AND CHANGES AT THE PROJECT SITE. 4.THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL REQUIREMENTS OF THE GENERAL PERMIT AND SWPPP, INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING BMP'S UNLESS INFEASIBLE OR NOT APPLICABLE: a.UTILIZE OUTLET STRUCTURES THAT WITHDRAW WATER FROM THE SURFACE WHEN DISCHARGING FROM BASINS, PROVIDE AND MAINTAIN NATURAL BUFFERS AROUND SURFACE WATERS, DIRECT STORM WATER TO VEGETATED AREAS TO INCREASE SEDIMENT REMOVAL AND MAXIMIZE STORM WATER INFILTRATION, AND MINIMIZE SOIL COMPACTION. b.INSTALL PERIMETER AND FINAL SEDIMENT CONTROL MEASURES SUCH AS SILT BARRIERS, DITCH CHECKS, DIVERSION BERMS, OR SEDIMENTATION BASINS DOWNSTREAM OF SOIL DISTURBING ACTIVITIES PRIOR TO SITE CLEARING AND GRADING OPERATIONS. c.PRESERVE EXISTING VEGETATION IN AREAS NOT NEEDED FOR CONSTRUCTION AND LIMIT TO A MINIMUM THE TOTAL AREA DISTURBED BY CONSTRUCTION OPERATIONS AT ANY TIME. d.MAINTAIN ALL TEMPORARY AND PERMANENT EROSION CONTROL MEASURES IN WORKING ORDER, INCLUDING CLEANING, REPAIRING, REPLACEMENT, AND SEDIMENT REMOVAL THROUGHOUT THE PERMIT PERIOD. CLEAN OR REPLACE SILT CONTROL DEVICES WHEN THE MEASURES HAVE LOST 50% OF THEIR ORIGINAL CAPACITY. e.INSPECT THE PROJECT AREA AND CONTROL DEVICES (BY QUALIFIED PERSONNEL ASSIGNED BY THE CONTRACTOR) EVERY SEVEN CALENDAR DAYS. RECORD THE FINDINGS OF THESE INSPECTIONS AND ANY RESULTING ACTIONS IN THE SWPPP WITH A COPY SUBMITTED WEEKLY TO THE OWNER OR ENGINEER DURING CONSTRUCTION. REVISE THE SWPPP AND IMPLEMENT ANY RECOMMENDED MEASURES WITHIN 7 DAYS. f.PREVENT ACCUMULATION OF EARTH AND DEBRIS FROM CONSTRUCTION ACTIVITIES ON ADJOINING PUBLIC OR PRIVATE PROPERTIES, INCLUDING STREETS, DRIVEWAYS, SIDEWALKS, DRAINAGEWAYS, OR UNDERGROUND SEWERS. REMOVE ANY ACCUMULATION OF EARTH OR DEBRIS IMMEDIATELY AND TAKE REMEDIAL ACTIONS FOR FUTURE PREVENTION. g.INSTALL NECESSARY CONTROL MEASURES SUCH AS SILT BARRIERS, EROSION CONTROL MATS, MULCH, DITCH CHECKS OR RIPRAP AS SOON AS AREAS REACH THEIR FINAL GRADES AND AS CONSTRUCTION OPERATIONS PROGRESS TO ENSURE CONTINUOUS RUNOFF CONTROL. PROVIDE INLET AND OUTLET CONTROL MEASURES AS SOON AS STORM SEWERS ARE INSTALLED. h.RESPREAD A MINIMUM OF 8 INCHES OF TOPSOIL (INCLUDING TOPSOIL FOUND IN SOD) ON ALL DISTURBED AREAS, EXCEPT WHERE PAVEMENT, BUILDINGS OR OTHER IMPROVEMENTS ARE LOCATED. i.STABILIZE UNDEVELOPED, DISTURBED AREAS WITH MULCH, TEMPORARY SEED MIX, PERMANENT SEED MIX, SOD, OR PAVEMENT IMMEDIATELY AS SOON AS POSSIBLE UPON COMPLETION OR DELAY OF GRADING OPERATIONS. INITIATE STABILIZATION MEASURES IMMEDIATELY AFTER CONSTRUCTION ACTIVITY IS FINALLY COMPLETED OR TEMPORARILY CEASED ON ANY PORTION OF THE SITE AND WHICH WILL NOT RESUME FOR A PERIOD EXCEEDING 14 CALENDAR DAYS. j.COORDINATE LOCATIONS OF STAGING AREAS WITH THE OWNER AND RECORD IN THE SWPPP. UNLESS NOTED OTHERWISE, STAGING AREAS SHOULD CONTAIN THE FOLLOWING: JOB TRAILERS, FUELING / VEHICLE MAINTENANCE AREA, TEMPORARY SANITARY FACILITIES, MATERIALS STORAGE, AND CONCRETE WASHOUT FACILITY. CONTROL RUNOFF FROM STAGING AREAS WITH DIVERSION BERMS AND/OR SILT BARRIERS AND DIRECT TO A SEDIMENT BASIN OR OTHER CONTROL DEVICE WHERE POSSIBLE. CONCRETE WASHOUT MUST BE CONTAINED ONSITE. k.REMOVE ALL TEMPORARY EROSION CONTROL MEASURES AND SITE WASTE PRIOR TO FILING OF THE "NOTICE OF DISCONTINUATION". GENERAL NOTES A. NOTIFY UTILITY PROVIDERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES AND COORDINATE WITH UTILITY PROVIDERS AS NECESSARY DURING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXISTENCE, EXACT LOCATION, AND DEPTH OF ALL UTILITIES. PROTECT ALL UTILITY LINES AND STRUCTURES NOT SHOWN FOR REMOVAL OR MODIFICATION. ANY DAMAGES TO UTILITY ITEMS NOT SHOWN FOR REMOVAL OR MODIFICATION SHALL BE REPAIRED TO THE UTILITY OWNER'S SPECIFICATIONS AT THE CONTRACTOR'S EXPENSE. B. CONSTRUCTION OF ALL STREET AND UTILITY IMPROVEMENTS SHALL CONFORM TO THE 2020 WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS, 2021 STATEWIDE URBAN DESIGN AND SPECIFICATIONS AND THE SOILS REPORTS PREPARED BY OTHERS. C. LENGTH OF UTILITIES SHOWN ON PLANS ARE DIMENSIONED FROM CENTERLINE OF STRUCTURE TO CENTERLINE OF STRUCTURE. D. ALL TRAFFIC CONTROL SHALL BE PROVIDED IN ACCORDANCE WITH REQUIREMENTS SET FORTH IN THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). WHEN CONSTRUCTION ACTIVITIES OBSTRUCT PORTIONS OF THE ROADWAY, FLAGGERS SHALL BE PROVIDED. FLAGGERS SHALL CONFORM TO THE MUTCD IN APPEARANCE, EQUIPMENT AND ACTIONS. THE CONTRACTOR SHALL NOTIFY THE CITY OF WAUKEE AT LEAST ONE WEEK PRIOR TO ANY ANTICIPATED LANE CLOSURE. E. NOTIFY OWNER, ENGINEER, CITY OF WAUKEE AT LEAST 48 HOURS PRIOR TO BEGINNING WORK. CONTRACTOR SHALL ALSO NOTIFY THE CITY OF WAUKEE ENGINEERING DEPARTMENT AT LEAST 48 HOURS PRIOR TO ANY PLANNED WEEKEND OR HOLIDAY WORK. F. CONSTRUCT MANHOLES AND APPURTENANCES AS WORK PROGRESSES. BACKFILL WITH SUITABLE MATERIAL AND COMPACT TO 95% MAXIMUM DENSITY. G. IN THE EVENT OF A DISCREPANCY BETWEEN THE QUANTITY ESTIMATES AND THE DETAILED PLANS, THE DETAILED PLANS SHALL GOVERN. H. ALL FIELD TILES ENCOUNTERED DURING CONSTRUCTION SHALL BE RECONNECTED OR REPAIRED AND NOTED ACCORDINGLY ON THE AS-BUILT DOCUMENTS. I. DIMENSIONS, BUILDING LOCATION, UTILITIES AND GRADING OF THIS SITE ARE BASED ON AVAILABLE INFORMATION AT THE TIME OF DESIGN. DEVIATIONS MAY BE NECESSARY IN THE FIELD. ANY SUCH CHANGES OR CONFLICTS BETWEEN THIS PLAN AND FIELD CONDITIONS ARE TO BE REPORTED TO THE ARCHITECT/ENGINEER PRIOR TO STARTING CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LAYOUT VERIFICATION OF ALL SITE IMPROVEMENTS PRIOR TO CONSTRUCTION. CONTACT CITY OF WAUKEE FOR APPROVAL OF ANY CHANGES AND THAT ANY CHANGES COMPLETED WITHOUT APPROVAL ARE SUBJECT TO REMOVAL IN ORDER TO MEET THE CITY OF WAUKEE STANDARDS. J. CONTRACTOR TO LOAD AND TRANSPORT ALL MATERIALS CONSIDERED TO BE UNDESIRABLE TO BE INCORPORATED INTO THE PROJECT TO AN APPROVED OFF-SITE WASTE SITE. K. CONTRACTOR TO STRIP AND STOCKPILE TOPSOIL FROM ALL AREAS TO BE CUT OR FILLED. RESPREAD TO MEET SUDAS SPECIFICATION SECTION 2010 FOR TOPSOIL. L. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS SHOWN ARE FINISHED GRADES AND/OR TOP OF PAVING SLAB (GUTTER), UNLESS OTHERWISE NOTED. M. THE CONTRACTOR IS RESPONSIBLE FOR CLEANING DIRT AND DEBRIS FROM NEIGHBORING STREETS, DRIVEWAYS, AND SIDEWALKS CAUSED BY CONSTRUCTION ACTIVITIES AT THE END OF EACH WORK DAY AND PRIOR TO A RAIN EVENT. N. THE ADJUSTMENT OF ANY EXISTING UTILITY APPURTENANCES TO FINAL GRADE IS CONSIDERED INCIDENTAL TO THE SITE WORK. O. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING EROSION AND SEDIMENT CONTROL MEASURES AS NECESSARY. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR MAINTAINING ANY EXISTING EROSION CONTROL MEASURES ON SITE AT THE TIME OF CONSTRUCTION. GRADING AND SOIL EROSION CONTROL CODE REQUIREMENTS SHALL BE MET BY CONTRACTOR. A COSESCO PERMIT IS REQUIRED FOR THIS PROJECT. P. CONTRACTOR TO COORDINATE NATURAL GAS, ELECTRICAL, TELEPHONE AND ANY OTHER FRANCHISE UTILITY SERVICES WITH UTILITY SERVICE PROVIDER, CITY OF WAUKEE, AND THE OWNER PRIOR TO CONSTRUCTION. Q. IF STORM SEWER CROSSES ABOVE WATER MAIN OR CROSSES LESS THAN 18" BELOW A WATER MAIN THEN STORM SEWER SHALL BE CONSTRUCTED OF REINFORCED CONCRETE WITH A FLEXIBLE O-RING GASKET RATED AT 13 PSI OR GREATER. O-RING GASKET JOINTS SHALL BE INSTALLED ON EACH SIDE OF THE CROSSING UNTIL THE NORMAL DISTANCE FROM THE WATER MAIN TO THE STORM SEWER IS AT LEAST TEN FEET. R. A PRE-CONSTRUCTION MEETING WITH THE CITY OF WAUKEE WILL BE REQUIRED A MINIMUM OF ONE WEEK PRIOR TO CONSTRUCTION ACTIVITIES BEGINNING. S. ALL STAKING SHALL BE DONE UNDER THE DIRECTION OF A LICENSED ENGINEER OR LAND SURVEYOR INCLUDING PEDESTRIAN FACILITIES. T. ANY CHANGES PROPOSED TO THE DRAWINGS DURING CONSTRUCTION SHALL BE APPROVED IN WRITING BY THE COMMUNITY DEVELOPMENT DEPARTMENT PRIOR TO CONSTRUCTION. U. THE CONTRACTOR IS RESPONSIBLE FOR ANY CHANGES MADE DURING CONSTRUCTION THAT HAVE NOT BEEN GRANTED APPROVAL IN WRITING BY THE COMMUNITY DEVELOPMENT DEPARTMENT. V. ALL SANITARY SEWER AND STORM SEWER SHALL BE CLEANED AND TELEVISED PRIOR TO PAVING. THE CITY OF WAUKEE SHALL WITNESS ALL CLEANING AND TELEVISING. COPIES OF THE REPORT AND VIDEO SHALL BE PROVIDED TO THE CITY OF WAUKEE. ALL SANITARY SEWER MANHOLES SHALL BE VACUUM TESTED. W. ALL CONSTRUCTION TO EXISTING SANITARY MANHOLES SHALL BE CORE DRILL WITH A LINK SEAL. X. PLACE 3/4" EXPANSION JOINT BETWEEN ALL PCC PAVEMENT/SIDEWALKS AND BUILDINGS. PLACE 1/2" EXPANSION JOINT BETWEEN SIDEWALKS AND PCC PAVEMENT. THE PCC RAMP JOINT LOCATED AT THE BACK OF CURB AND ALL EXPANSION JOINTS SHALL BE SEALED. Y. ALL UTILITIES INCLUDING PRIVATE UTILITIES SHALL BE CONSTRUCTED TO THE CITY OF WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND ALL UTILITIES SHALL BE TESTED TO CITY STANDARDS. THE CITY SHALL WITNESS ALL TESTING. Z. CONTRACTOR SHALL PROTECT STORM SEWERS AND DRAINAGE WAYS FROM ALLOWING CONCRETE SLURRY FROM CONCRETE OPERATIONS TO DISCHARGE OFFSITE. AA. CONTRACTOR SHALL COORDINATE ALL TIE-IN TO UTILITIES WITH THE CITY OF WAUKEE PUBLIC WORKS DEPARTMENT AND CITY OF WAUKEE PUBLIC WORKS SHALL WITNESS ALL TIE-INS. BB. THE COOP ASSOCIATION SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF THE PRIVATE STREETS, MONUMENT SIGN AND ALL PRIVATE UTILITIES WITHIN THE DEVELOPMENT. CC. ALL FIRE HYDRANTS TO HAVE 5 INCH STORZ FITTINGS. DD. CONTRACTOR TO INSTALL STREET BLADE SIGNS FOR PRIVATE STREETS AT THE TIME VERTICAL CONSTRUCTION BEGINS. 1 (2620) 2 (2610) 3 (2600) 4 (2590) 5 (2580) 6 (2570) 7 (2560) 8 (2550) 9 (2540) 10 (2535) 11 (2525) 12 (2515) 13 (2505)14 (2495) 15 (2485) 16 (2475) 17 (2465) 18 (2455) 19 (2445) 20 (2435) 21 (2430) 22 (2420) 23 (2410) 24 (2400) 25 (2390) 26 (2395) 27 (2405) 28 (2415) 29 (2425)SE V I N T A G E L N SE V I N T A G E L N POOL CLUBHOUSE 2460 RISER 20 ' B u i l d i n g S e t b a c k 20' B u i l d i n g S e t b a c k 20' Bui l d i n g S e t b a c k BM500 BM501 100 101 103 ConcreteSE Tallgrass Lan e Co n c r e t e SE P a r k v i e w C r o s s i n g D r i v e Concrete SE Esker R i d g e D r i v e Con c r e t e SE E s k e r R i d g e D r i v e Concrete Sidewalk Planter Area Wood Fence Concrete Sidewalk Rim=1034.41 F.L.=1021.09 8" TRUSS NE F.L.=1021.09 8" TRUSS W Rim=1036.72 F.L.=1024.27 8" TRUSS E F.L.=1024.70 8" TRUSS W Rim=1049.00 F.L.=1036.36 8" TRUSS E Rim=1042.83 F.L.=1038.71 8" CMP W F.L.= 1038.52 18" RCP E Intake=1042.22 F.L.=1038.57 15" RCP N Intake=1042.22 F.L.=1039.05 15" RCP S Rim=1035.69 F.L.=1030.89 18" RCP W F.L.= 1030.89 18" RCP E Intake=1035.00 F.L.=1030.84 15" RCP N Intake=1034.98 F.L.=1031.53 15" RCP S Rim=1033.15 F.L.=1026.19 15" RCP W F.L.= 1026.19 18" RCP SE Intake=1032.45 F.L.=1028.30 15" RCP N Intake=1032.45 F.L.=1028.80 15" RCP S Intake=1033.18 F.L.=1026.14 24" RCP NE Intake=1032.41 F.L.=1025.49 24" RCP SW F.L.=1025.28 18" RCP NW F.L.=1025.14 24" RCP E Intake=1032.54 F.L.=1024.65 24" RCP W Intake=1034.10 F.L.=1030.05 15" RCP E Intake=1034.16 F.L.=1029.66 15" RCP W Intake=1039.00 F.L.=1034.95 15" RCP E Intake=1038.98 F.L.=1034.54 15" RCP W Intake=1044.51 F.L.=1040.30 15" RCP SW Intake=1044.57 F.L.=1040.25 15" RCP NE Concrete Sidewalk Rim=1045.40 F.L.=1040.61 15" RCP W F.L.= 1040.21 18" RCP SE Rim=1047.41 F.L.=1041.50 15" RCP SE F.L.= 1041.50 15" RCP SW Rim=1049.70 F.L.=1042.30 15" RCP NE F.L.= 1042.30 15" RCP SW Rim=1047.96 F.L.=1043.20 15" RCP NE Intake=1047.21 F.L.=1043.10 15" RCP NW Intake=1047.19 F.L.=1043.37 15" RCP SE Rim=1032.95 F.L.=1018.34 8" TRUSS N F.L.=1018.73 8" TRUSS SE F.L.=1018.14 8" TRUSS E F.L.=1018.14 8" TRUSS W Transformer MidAmerican Transformer MidAmerican N83°56'08"E 411. 6 4 ' M N83°41'41"E 411. 6 4 ' P C1 C2 C3 C4 C5 N37°28'27"E 62.82' M S37°14'00"W 62.82' P N0 ° 3 3 ' 1 9 " E 7 9 2 . 7 0 ' M N0 0 ° 1 8 ' 5 5 " E 7 9 2 . 7 0 ' P 343,965 SF 7.90 AC Lot 1 131,800 SF 3.03 AC Lot 2 C 7 C9 C10 C8 C6 150 ' E X I S T I N G H Y D R A N T C O V E R A G E 150' EXISTING HYDRANT COVERAGE 150' E X I S T I N G H Y D R A N T COV E R A G E 150' PRO P O S E D H Y D R A N T C O V E R A G E 1 5 0 ' P R O P O S E D H Y D R A N T C O V E R A G E 15 0 ' P R O P O S E D H Y D R A N T C O V E R A G E 150' PROPOS E D H Y D R A N T C O V E R A G E 150' PROPOS E D H Y D R A N T C O V E R A G E 150' EXISTING HYD R A N T C O V E R A G E 15 0 ' E X I S T I N G H Y D R A N T C O V E R A G E 150 ' E X I S T I N G H Y D R A N T C O V E R A G E 15 0 ' E X I S T I N G HY D R A N T CO V E R A G E 150' E X I S T I N G HY D R A N T C O V E R A G E 15 0 ' E X I S T I N G H Y D R A N T C O V E R A G E 15' Private Storm Sewer and Overland Flowage Easement 10' PUE 10' PUE 10' PUE 54' Public Ingress/Egress Easement 45' Public Ingress/Egress Easement 15' Private Overland Flowage Easement 15' Private Overland Flowage Easement 15' Private Overland Flowage Easement 10' PUE 10' PUE 20' Private Overland Flowage Easement 20' Private Overland Flowage Easement 45' Public Ingress/Egress Easement 5' Public Gas Easement 5' Public Gas Easement 15 0 ' P R O P O S E D H Y D R A N T C O V E R A G E 5' Public Gas Easement 15' Private Overland Flowage Easement BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m JA L RM B LB W 09 - 2 8 - 2 0 2 1 50 ' 12 1 . 0 4 7 6 C2 0 0 121.0476 C200 VI N T A G E E S T A T E S O F W A U K E E HY D R A N T C O V E R A G E P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 10 / 2 6 / 2 1 11 / 1 1 / 2 1 12 / 0 9 / 2 1 03 / 3 0 / 2 2 RM B RM B LM W LM W 2345 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 1 \ 1 2 1 . 0 4 7 6 . 0 1 \ C A D D \ S P _ 1 2 1 0 4 7 6 _ H Y D T . d w g LO R E N A W A S I O N , HY D R A N T C O V E R A G E P L A N , 20 2 2 / 0 3 / 3 0 , 1: 5 4 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 50 1 (2620) 2 (2610) 3 (2600) 4 (2590) 5 (2580) 6 (2570) 7 (2560) 8 (2550) 9 (2540) 10 (2535) 11 (2525) 12 (2515) 13 (2505)14 (2495) 15 (2485) 16 (2475) 17 (2465) 18 (2455) 19 (2445) 20 (2435) 21 (2430) 22 (2420) 23 (2410) 24 (2400) 25 (2390) 26 (2395) 27 (2405) 28 (2415) 29 (2425)SE V I N T A G E L N SE V I N T A G E L N POOL CLUBHOUSE 2460 RISER 20 ' B u i l d i n g S e t b a c k 20' B u i l d i n g S e t b a c k 20' Bui l d i n g S e t b a c k BM500 BM501 100 101 103 104 ConcreteSE Tallgrass Lan e Co n c r e t e SE P a r k v i e w C r o s s i n g D r i v e Concrete SE Esker R i d g e D r i v e Con c r e t e SE E s k e r R i d g e D r i v e Concrete Sidewalk Planter Area Wood Fence Concrete Sidewalk Rim=1034.41 F.L.=1021.09 8" TRUSS NE F.L.=1021.09 8" TRUSS W Rim=1036.72 F.L.=1024.27 8" TRUSS E F.L.=1024.70 8" TRUSS W Rim=1049.00 F.L.=1036.36 8" TRUSS E Rim=1042.83 F.L.=1038.71 8" CMP W F.L.= 1038.52 18" RCP E Intake=1042.22 F.L.=1038.57 15" RCP N Intake=1042.22 F.L.=1039.05 15" RCP S Rim=1035.69 F.L.=1030.89 18" RCP W F.L.= 1030.89 18" RCP E Intake=1035.00 F.L.=1030.84 15" RCP N Intake=1034.98 F.L.=1031.53 15" RCP S Rim=1033.15 F.L.=1026.19 15" RCP W F.L.= 1026.19 18" RCP SE Intake=1032.45 F.L.=1028.30 15" RCP N Intake=1032.45 F.L.=1028.80 15" RCP S Intake=1033.18 F.L.=1026.14 24" RCP NE Intake=1032.41 F.L.=1025.49 24" RCP SW F.L.=1025.28 18" RCP NW F.L.=1025.14 24" RCP E Intake=1032.54 F.L.=1024.65 24" RCP W Intake=1034.10 F.L.=1030.05 15" RCP E Intake=1034.16 F.L.=1029.66 15" RCP W Intake=1039.00 F.L.=1034.95 15" RCP E Intake=1038.98 F.L.=1034.54 15" RCP W Intake=1044.51 F.L.=1040.30 15" RCP SW Intake=1044.57 F.L.=1040.25 15" RCP NE Concrete Sidewalk The Estates Of Waukee Large Sign For Sale Sign Rim=1045.40 F.L.=1040.61 15" RCP W F.L.= 1040.21 18" RCP SE Rim=1047.41 F.L.=1041.50 15" RCP SE F.L.= 1041.50 15" RCP SW Rim=1049.70 F.L.=1042.30 15" RCP NE F.L.= 1042.30 15" RCP SW Rim=1047.96 F.L.=1043.20 15" RCP NE Intake=1047.21 F.L.=1043.10 15" RCP NW Intake=1047.19 F.L.=1043.37 15" RCP SE Rim=1032.95 F.L.=1018.34 8" TRUSS N F.L.=1018.73 8" TRUSS SE F.L.=1018.14 8" TRUSS E F.L.=1018.14 8" TRUSS W Notice Of Rezoning Sign For Sale Sign Notice Of Rezoning Sign For Sale Sign Notice Of Rezoning Sign Transformer MidAmerican Transformer MidAmerican N83°56'08"E 411. 6 4 ' M N83°41'41"E 411. 6 4 ' P C1 C2 C3 C4 C5 N37°28'27"E 62.82' M S37°14'00"W 62.82' P N0 ° 3 3 ' 1 9 " E 7 9 2 . 7 0 ' M N0 0 ° 1 8 ' 5 5 " E 7 9 2 . 7 0 ' P 343,965 SF 7.90 AC Lot 1 131,800 SF 3.03 AC Lot 2 C 7 C9 C10 C8 C6 19.7' 5.0' 25.0'22.0' 9. 0 ' T Y P 2 2 . 0 ' 2 5 . 0 ' 5 . 0 ' 18.0' TYP 22 . 0 ' 5. 0 ' 25 . 0 ' 22 . 0 ' 10.0' 26.0'25.0' 5.0' 50.5' 74.7' TYP 42 . 0 ' T Y P 74.7' TYP 42 . 0 ' T Y P 12 . 0 ' 10.0' 12.0'17.0' 11 . 0 ' 12.0'10.0' 10 . 0 ' 11 . 0 ' 2 0 . 9 ' 20 . 0 ' 12.0' 10.0' 11 . 0 ' 1 0 . 0 ' TYP TYP TYP TYP 3 1 . 7 ' 32.5' 3 2 . 0 ' E x 3 1 ' B / B E x 7 0 ' R O W Ex 31' B / B Ex 70' R O W E x 2 9 . 0 ' B / B E x 6 0 ' R O W 12 . 0 ' 12.0 ' 12.0' 12.0' 12 . 0 ' 12 . 0 ' 12 . 0 ' 12 . 0 ' 11 . 0 ' 12.0' 10.0' 3 0 . 6 ' 20 . 0 ' 6,507 SF 1 9 . 4 ' 15' Private Storm Sewer and Overland Flowage Easement 10' PUE 10' PUE 10' PUE 45' Public Ingress/Egress Easement 15' Private Overland Flowage Easement 15' Private Overland Flowage Easement 15' Private Overland Flowage Easement 20' Private Overland Flowage Easement 20' Private Overland Flowage Easement 10' PUE 10' PUE 1A 1A 1A 1A 1A 1A 1A 1A 1A 1A 1A 1A 1B 1B 1B 1B 2A 2A 2A 2H 2H 2H 2B 2B 2C 2C 2C 2J 2I 3A 3C 3B 2E 2G 2D 4A 2D 2E 2E 2F 2D 4B 4B 5 2K 2C 2B 1C 1C 45' Public Ingress/Egress Easement 130.0' 77 . 7 ' 77.3' 39 . 4 ' 6 6 5' Public Gas Easement 5' Public Gas Easement 41' 13 . 4 ' 15' Private Overland Flowage Easement 5' Public Gas Easement 54' Public Ingress Egress Easement 5' Electrical Easement 5' Electrical Easement 5' Electrical Easement BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m JA L RM B LB W 09 - 2 8 - 2 0 2 1 50 ' 12 1 . 0 4 7 6 C3 0 0 121.0476 C300 VI N T A G E E S T A T E S O F W A U K E E DI M E N S I O N P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 10 / 2 6 / 2 1 11 / 1 1 / 2 1 12 / 0 9 / 2 1 03 / 3 0 / 2 2 RM B RM B LM W LM W 2345 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 1 \ 1 2 1 . 0 4 7 6 . 0 1 \ C A D D \ S P _ 1 2 1 0 4 7 6 _ D I M S . d w g LO R E N A W A S I O N , DI M E N S I O N P L A N , 20 2 2 / 0 3 / 3 0 , 1: 5 4 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 50 DIMENSION PLAN CONSTRUCTION NOTES 1. PROTECT THE FOLLOWING SITE FEATURES: A.EXISTING UTILITY. ADJUST AS NECESSARY TO ALLOW FOR CONSTRUCTION. VERIFY LOCATION, ELEVATION AND MINIMUM COVER REQUIREMENTS PRIOR TO CONSTRUCTION. B.EXISTING PAVEMENT. C.EXISTING STREET LIGHT. ANY ELECTRIC FOR STREET LIGHTS OR ANY LIGHT POLE THAT NEEDS TO BE RELOCATED WILL BE AT THE EXPENSE OF THE DEVELOPER. 2.PAVEMENTS, PROVIDE THE FOLLOWING: A.7" DEPTH PCC PAVEMENT ON 12" DEPTH PREPARED SUBGRADE COMPACTED TO 95% STANDARD PROCTOR DENSITY. B.4" MINIMUM DEPTH PCC SIDEWALK ON 6" DEPTH PREPARED SUBGRADE COMPACTED TO 95% STANDARD PROCTOR DENSITY. C.3" PCC ROLL CURB. D.PEDESTRIAN RAMP WITH MAXIMUM SLOPE OF 8.33%. PROVIDE DETECTABLE WARNING PANELS WHERE SHOWN. E.5" PCC DRIVEWAY TO BE BUILT WITH HOME CONSTRUCTION. F. 6" DEPTH PCC PAVEMENT ON 12" DEPTH PREPARED SUBGRADE COMPACTED TO 95% STANDARD PROCTOR DENSITY. G.8" PCC, 4'X4' CLUSTER MAIL BOX PAD. SEE DETAIL SHEET C504. H.INTEGRAL CURB AND 4" PCC SIDEWALK. I.8" DEPTH PCC TYPE A ENTRANCE APPROACH TO BE CONSTRUCTED AS PER STANDARD SPECIFICATIONS. J.SUDAS TYPE A CONNECTION. K.PAVED INTEGRAL CURB. 3.PAVEMENT MARKINGS, PROVIDE THE FOLLOWING: A.PAINTED PARKING STALL LINE, 4" WIDE, PAINTED YELLOW. B.PAINTED 45° STRIPING AT 3' O.C. C.PAINTED STATE OF IOWA APPROVED DISABLED SYMBOL. AS PER ADAAG REQUIREMENTS. 4.SIGNAGE PROVIDE THE FOLLOWING: A.BLUE SIGN WITH DISABLED SYMBOL READING "PARKING ONLY" AND "$200 FINE FOR IMPROPER USE" AS PER ADAAG STANDARDS. SECURE SIGN TO 2" SQUARE STEEL CHANNEL POST WITH ENAMEL FINISH IN A 12" DIAMETER CONCRETE FOOTING. ALSO ADD SIGN READING "VAN ACCESSIBLE". B.STOP SIGN. CONTRACTOR TO INSTALL. STREET BLADE SIGN TO BE INSTALLED PRIOR TO VERTICAL CONSTRUCTION. 5. ENTRANCE GATE WITH KEY PAD TO BE SELECTED BY OWNER. COORDINATE ACCESS WTH WAUKEE FIRE DEPARTMENT, TRASH PROVIDER, WAUKEE POLICE DEPARTMENT AND USPS. 6.MODULAR BLOCK RETAINING WALL. SEE DETAIL. NOT TO SCALE TYPICAL PRIVATE STREET CROSS SECTION4 C300 LEGEND 8" DEPTH PCC 7" DEPTH PCC 6" DEPTH PCC 4" DEPTH PCC SIDEWALK 3 C300 NOT TO SCALE INTEGRAL 3" ROLLED CURB AND SIDEWALK DETAIL PCC SIDEWALK SECTION PCC PAVEMENT SECTION 2 C300 NOT TO SCALE TYPICAL PAVEMENT CROSS SECTIONS 2"R 1"R 10.5" 2.5" VA R I E S 3"Sidewalk 4"min. 2% max. Sealed 'E' joint 1 C300 NOT TO SCALE 74 . 7 ' 42.0' 22 . 0 ' 5. 0 ' 25 . 0 ' B/ B 20.0' TYPICAL MAXIMUM UNIT DETAIL OPTIONAL PORCH TYPICAL SECTION Exact dimensions, wall batter, backfill limits, reinforcement, and leveling pad materials and dimensions will be specified by the wall manufacturer. 1 5 C300 MODULAR BLOCK RETAINING WALL NO SCALE 8" M i n . 6" M i n . 6" M i n . 4' - 0 " m a x . Topsoil or Suitable Backfill Material Granular Backfill Material Geogrid (if required) Excavation Line Geogrid (if required) Subdrain Wrap porous backfill material with engineering fabric. Excavation Line Finished Grade Wall Unit (Typ.) Finished Grade (slope varies) Pins or Lip to Ensure Proper Block Setback Cap Stone Compacted Foundation Construct a 6" thick X 18" wide (min.) leveling pad 1 (2620) 2 (2610) 3 (2600) 4 (2590) 5 (2580) 6 (2570) 7 (2560) 8 (2550) 9 (2540) 10 (2535) 11 (2525) 12 (2515) 13 (2505)14 (2495) 15 (2485) 16 (2475) 17 (2465) 18 (2455) 19 (2445) 20 (2435) 21 (2430) 22 (2420) 23 (2410) 24 (2400) 25 (2390) 26 (2395) 27 (2405) 28 (2415) 29 (2425)SE V I N T A G E L N SE V I N T A G E L N POOL CLUBHOUSE 2460 RISER 20 ' B u i l d i n g S e t b a c k 20' B u i l d i n g S e t b a c k 20' Bui l d i n g S e t b a c k BM500 BM501 100 101 103 ConcreteSE Tallgrass Lan e Co n c r e t e SE P a r k v i e w C r o s s i n g D r i v e Concrete SE Esker R i d g e D r i v e Con c r e t e SE E s k e r R i d g e D r i v e Concrete Sidewalk Planter Area Wood Fence Concrete Sidewalk Rim=1034.41 F.L.=1021.09 8" TRUSS NE F.L.=1021.09 8" TRUSS W Rim=1036.72 F.L.=1024.27 8" TRUSS E F.L.=1024.70 8" TRUSS W Rim=1049.00 F.L.=1036.36 8" TRUSS E Rim=1042.83 F.L.=1038.71 8" CMP W F.L.= 1038.52 18" RCP E Intake=1042.22 F.L.=1038.57 15" RCP N Intake=1042.22 F.L.=1039.05 15" RCP S Rim=1035.69 F.L.=1030.89 18" RCP W F.L.= 1030.89 18" RCP E Intake=1035.00 F.L.=1030.84 15" RCP N Intake=1034.98 F.L.=1031.53 15" RCP S Rim=1033.15 F.L.=1026.19 15" RCP W F.L.= 1026.19 18" RCP SE Intake=1032.45 F.L.=1028.30 15" RCP N Intake=1032.45 F.L.=1028.80 15" RCP S Intake=1033.18 F.L.=1026.14 24" RCP NE Intake=1032.41 F.L.=1025.49 24" RCP SW F.L.=1025.28 18" RCP NW F.L.=1025.14 24" RCP E Intake=1032.54 F.L.=1024.65 24" RCP W Intake=1034.10 F.L.=1030.05 15" RCP E Intake=1034.16 F.L.=1029.66 15" RCP W Intake=1039.00 F.L.=1034.95 15" RCP E Intake=1038.98 F.L.=1034.54 15" RCP W Intake=1044.51 F.L.=1040.30 15" RCP SW Intake=1044.57 F.L.=1040.25 15" RCP NE Concrete Sidewalk Rim=1045.40 F.L.=1040.61 15" RCP W F.L.= 1040.21 18" RCP SE Rim=1047.41 F.L.=1041.50 15" RCP SE F.L.= 1041.50 15" RCP SW Rim=1049.70 F.L.=1042.30 15" RCP NE F.L.= 1042.30 15" RCP SW Rim=1047.96 F.L.=1043.20 15" RCP NE Intake=1047.21 F.L.=1043.10 15" RCP NW Intake=1047.19 F.L.=1043.37 15" RCP SE Rim=1032.95 F.L.=1018.34 8" TRUSS N F.L.=1018.73 8" TRUSS SE F.L.=1018.14 8" TRUSS E F.L.=1018.14 8" TRUSS W Transformer MidAmerican Transformer MidAmerican N83°56'08"E 411. 6 4 ' M N83°41'41"E 411. 6 4 ' P C1 C2 C3 C4 C5 N37°28'27"E 62.82' M S37°14'00"W 62.82' P N0 ° 3 3 ' 1 9 " E 7 9 2 . 7 0 ' M N0 0 ° 1 8 ' 5 5 " E 7 9 2 . 7 0 ' P 343,965 SF 7.90 AC Lot 1 131,800 SF 3.03 AC Lot 2 C 7 C9 C10 C8 C6 MANHOLE NO. 1, SW-301 RIM: 1048.96 INV: 1037.11 (OUT N) MANHOLE NO. 3, SW-301 RIM: 1046.54 INV: 1029.13 (IN S) INV: 1028.88 (OUT E) MANHOLE NO. 2, SW-301 RIM: 1045.38 INV: 1030.89 (IN S) INV: 1030.79 (OUT N) MANHOLE NO. 5, SW-301 RIM: 1044.96 INV: 1033.60 (OUT E) MANHOLE NO. 6, SW-301 RIM: 1042.70 INV: 1031.43 (IN W) INV: 1031.33 (OUT NE) MANHOLE NO. 4, SW-301 RIM: 1042.17 INV: 1027.99 (IN W) INV: 1027.89 (OUT E) MANHOLE NO. 7, SW-301 RIM: 1041.79 INV: 1030.50 (IN SW) INV: 1030.40 (OUT N) MANHOLE NO. 9, SW-301 RIM: 1039.50 INV: 1027.27 (IN W) INV: 1027.27 (IN SE) INV: 1027.00 (OUT NE) MANHOLE NO. 8, SW-301 RIM: 1039.26 INV: 1028.18 (IN S) INV: 1028.08 (OUT NW) 89 LF OF 8"SANITARY S E W E R @ 0 . 7 0 % 128 L F O F 8 " SANIT A R Y S E W E R @ 0 . 7 0 % 23 7 L F O F 8 " S A N I T A R Y S E W E R @ 0 . 7 0 % 19 5 L F O F 8 " S A N I T A R Y S E W E R @ 3 . 2 0 % 165 LF OF 8" SANITARY SEWER @ 1.32% 64 LF OF 8" SANITARY SEWER @ 1.30% 18 5 L F O F 8 " S A N I T A R Y S E W E R @ 1 . 2 0 % 68 LF OF 8" SANITARY SEWER @ 1.20%18 4 L F O F 8 " S A N I T A R Y S E W E R @ 1 . 1 1 % 1A 1A 1A 1A 1A 1A 1A 1A 1A 1A 1A 1A 2A 2B TYP 2B TYP 2B TYP 2C 2C 2C 2C 3A 3B 3B 3B 3B 3B 3C TYP 3C TYP 3CTYP 3F 3E 3D 3D 3D 3D 3E 3E 4 INV=1024.96 15' Private Storm Sewer and Overland Flowage Easement 10' PUE 10' PUE 10' PUE 54' Public Ingress/Egress Easement 45' Public Ingress/Egress Easement 15' Private Overland Flowage Easement 15' Private Overland Flowage Easement 15' Private Overland Flowage Easement 20' Private Overland Flowage Easement 10' PUE 10' PUE 20' Private Overland Flowage Easement 45' Private Ingress/Egress Easement 5A 5A 5A 5A 3G 5C 4.0' 4.0' 4 . 0 ' 3H BP=1038.87(W) TP=1032.04(SAN) 3K BP=1 0 3 3 . 2 7 ( S T ) TP=1 0 3 1 . 7 7 ( W ) 3H BP= 1 0 3 3 . 3 3 ( W ) TP= 1 0 2 7 . 5 6 ( S A N ) 5' Public Gas Easement 5' Public Gas Easement 3J 3I 3H BP=1033.65(ST) TP=1031.77(SAN) 3H BP = 1 0 3 6 . 6 8 ( S T ) TP = 1 0 3 1 . 6 3 ( S A N ) 3H BP=1039.90(ST) TP=1033.11(SAN) 3H BP=1040.15(ST) TP=1031.19(SAN) 3D 3D 3H BP=1030.50(ST) TP=1024.92(SAN) 3H BP=1039.34(ST) TP=1037.84(W) 5' Public Gas Easement 5A 5A 5A 15' Private Overland Flowage Easement 5 5 5 5' Electrical Easement 5' Electrical Easement 5' Electrical Easement 5' Electrical Easement BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m JA L RM B LB W 09 - 2 8 - 2 0 2 1 50 ' 12 1 . 0 4 7 6 C4 0 0 121.0476 C400 VI N T A G E E S T A T E S O F W A U K E E UT I L I T Y P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 10 / 2 6 / 2 1 11 / 1 1 / 2 1 12 / 0 9 / 2 1 03 / 3 0 / 2 2 RM B RM B LM W LM W 2345 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 1 \ 1 2 1 . 0 4 7 6 . 0 1 \ C A D D \ S P _ 1 2 1 0 4 7 6 _ U T I L . d w g LO R E N A W A S I O N , UT I L I T Y P L A N , 20 2 2 / 0 3 / 3 0 , 1: 5 4 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 50 UTILITY PLAN CONSTRUCTION NOTES 1. EXISTING FEATURES, PROTECT THE FOLLOWING: A.EXISTING UTILITIES. ANY DAMAGES TO EXISTING UTILITIES THAT ARE NOT SCHEDULED FOR MODIFICATION OR DEMOLITION SHALL BE REMEDIED AT THE CONTRACTOR'S EXPENSE WITH THE WORK BEING PERFORMED TO THE UTILITY OWNER'S SPECIFICATIONS. 2.PRIVATE SANITARY SEWER SERVICE. A.CORE DRILL AND CONNECT TO EXISTING SANITARY MANHOLE. CONTRACTOR TO VERIFY PRIOR TO CONSTRUCTION. B.4" SANITARY SEWER SERVICE LINE (PVC SDR 23.5) AT MINIMUM 2.0%. C.INSTALL 8" PRIVATE SANITARY SEWER MAIN PER CITY OF WAUKEE STANDARD SPECIFICATIONS. MAIN SHALL BE PVC, TRUSS PIPE. 3.PRIVATE WATER SERVICE. PROVIDE THE FOLLOWING AS PER CITY OF WAUKEE STANDARDS. A.CONNECTION TO EXISTING 8" WATER MAIN WITH TAPPING VALVE AND SLEEVE. VERIFY LOCATION AND ELEVATION. B.8" WATER LINE WITH FITTINGS AND BENDS AS NECESSARY. MINIMUM 5.5' DEEP. C.1" WATER SERVICE WITH CURB STOP. INSTALL WATER SERVICE AS PER CITY OF WAUKEE STANDARD SPECIFICATIONS D.HYDRANT ASSEMBLY. E.8" VALVE. F.8" TEE. G. FIRE DEPARTMENT CONNECTION. SEE ARCHITECTURAL PLANS FOR LOCATION PRIOR TO CONSTRUCTION. H.CRITICAL CROSSING. MAINTAIN MINIMUM 18" SEPARATION BETWEEN ALL OTHER UTILITIES. I.6" PRIVATE WATER SERVICE. J.CURB STOP. K.WHERE THE WATER MAIN IS LOCATED BELOW THE STORM SEWER, PROVIDE GASKETED JOINTS FOR RCP STORM SEWER LOCATION WITHIN 10 FEET OF CROSSING 4.COORDINATE NATURAL GAS AND ELECTRICAL SERVICES AND METER LOCATION WITH UTILITY SERVICE PROVIDER PRIOR TO CONSTRUCTION. SEE ARCHITECTURAL AND MECHANICAL PLANS FOR INTERIOR UTILITY ROUTING,METERS, DESIGN INFORMATION AND COORDINATE UTILITY CONNECTIONS ACCORDINGLY. 5.ELECTRICAL SERVICES AS PER CITY OF WAUKEE STANDARDS. ALL ELECTRICAL CONDUIT, TRANSFORMER BASES, AND SECONDARY HANDHOLES TO BE PROVIDED AND INSTALLED BY OWNER. A.STREET LIGHT. 1 C400 SERVICE LOCATION DETAIL NO SCALE STOP SANITARY SERVICE ROCK BEDDING AT THE ROW LINE NOTES: 1.PAINT CURB RED FOR SANITARY, GREEN FOR SUMP SERVICES, AND BLUE FOR WATER SERVICE. 2. PLACE ONE 6 FT. STEEL POST BURIED 3 FT. AT WATER CURB BOX AND SEWER SERVICE STUB. WA T E R S E R V I C E 5 . 5 ' D E E P SA N I T A R Y S E W E R 1 0 - 1 2 ' D E E P SU M P S E R V I C E M I N . 4 ' D E E P 24"24" CO M P A C T E D S O I L STOP @ 20' FROM BOC (UNITS 1-25) STOP @ 25' FROM BOC (UNITS 26-29) 20 ' B u i l d i n g S e t b a c k 20' Bu i l d i n g S e t b a c k 20' Bui l d i n g S e t b a c k BM500 BM501 100 101 103 ConcreteSE Tallgrass Lan e Co n c r e t e SE P a r k v i e w C r o s s i n g D r i v e Concrete SE Esker R i d g e D r i v e Con c r e t e SE E s k e r R i d g e D r i v e Concrete Sidewalk Planter Area Wood Fence Concrete Sidewalk Rim=1034.41 F.L.=1021.09 8" TRUSS NE F.L.=1021.09 8" TRUSS W Rim=1036.72 F.L.=1024.27 8" TRUSS E F.L.=1024.70 8" TRUSS W Rim=1049.00 F.L.=1036.36 8" TRUSS E Rim=1042.83 F.L.=1038.71 8" CMP W F.L.= 1038.52 18" RCP E Intake=1042.22 F.L.=1038.57 15" RCP N Intake=1042.22 F.L.=1039.05 15" RCP S Rim=1035.69 F.L.=1030.89 18" RCP W F.L.= 1030.89 18" RCP E Intake=1035.00 F.L.=1030.84 15" RCP N Intake=1034.98 F.L.=1031.53 15" RCP S Rim=1033.15 F.L.=1026.19 15" RCP W F.L.= 1026.19 18" RCP SE Intake=1032.45 F.L.=1028.30 15" RCP N Intake=1032.45 F.L.=1028.80 15" RCP S Intake=1033.18 F.L.=1026.14 24" RCP NE Intake=1032.41 F.L.=1025.49 24" RCP SW F.L.=1025.28 18" RCP NW F.L.=1025.14 24" RCP E Intake=1032.54 F.L.=1024.65 24" RCP W Intake=1034.10 F.L.=1030.05 15" RCP E Intake=1034.16 F.L.=1029.66 15" RCP W Intake=1039.00 F.L.=1034.95 15" RCP E Intake=1038.98 F.L.=1034.54 15" RCP W Intake=1044.51 F.L.=1040.30 15" RCP SW Intake=1044.57 F.L.=1040.25 15" RCP NE Concrete Sidewalk Rim=1045.40 F.L.=1040.61 15" RCP W F.L.= 1040.21 18" RCP SE Rim=1047.41 F.L.=1041.50 15" RCP SE F.L.= 1041.50 15" RCP SW Rim=1049.70 F.L.=1042.30 15" RCP NE F.L.= 1042.30 15" RCP SW Rim=1047.96 F.L.=1043.20 15" RCP NE Intake=1047.21 F.L.=1043.10 15" RCP NW Intake=1047.19 F.L.=1043.37 15" RCP SE Rim=1032.95 F.L.=1018.34 8" TRUSS N F.L.=1018.73 8" TRUSS SE F.L.=1018.14 8" TRUSS E F.L.=1018.14 8" TRUSS W Transformer MidAmerican Transformer MidAmerican ST-4A, 24" NYLOPLAST DRAIN BASIN W/ SOLID LID RIM: 1045.97 INV: 1036.99 (IN SW) INV: 1036.89 (OUT E) ST-14A, SW-401 RIM: 1045.46 INV: 1039.13 (OUT E)ST-8, SW-501 T/C: 1045.71 INV: 1040.60 (OUT E) ST-9, SW-501 T/C: 1045.71 INV: 1040.10 (IN W) INV: 1039.24 (IN S) INV: 1039.14 (OUT N) ST-7, SW-501 T/C: 1045.15 INV: 1039.89 (IN W) INV: 1039.78 (IN S) INV: 1039.68 (OUT N) ST-6, SW-501 T/C: 1045.15 INV: 1040.35 (OUT E) ST-3A, 18" NYLOPLAST DRAIN BASIN W/ SOLID LID RIM: 1044.91 INV: 1038.66 (IN S) INV: 1038.56 (OUT N) ST-3, 18" NYLOPLAST DRAIN BASIN W/ DOMED GRATE RIM: 1044.50 INV: 1039.64 (IN S) INV: 1039.54 (OUT N) ST-2, 18" NYLOPLAST DRAIN BASIN W/ DOMED GRATE RIM: 1044.50 INV: 1040.82 (IN S) INV: 1040.72 (OUT N) ST-1, 18" NYLOPLAST DRAIN BASIN W/ DOMED GRATE RIM: 1044.50 INV: 1041.90 (OUT N) ST-4, 24" NYLOPLAST DRAIN BASIN W/ DOMED GRATE RIM: 1043.35 INV: 1037.79 (IN S) INV: 1037.69 (OUT NE) ST-16, SW-505 T/C: 1039.24 INV: 1033.66 (IN SW) INV: 1033.56 (OUT NE) ST-15, SW-505 T/C: 1039.24 INV: 1034.09 (IN W) INV: 1034.09 (IN S) INV: 1033.99 (OUT NE) ST-16A, SW-401 RIM: 1037.71 INV: 1031.06 (IN SW) INV: 1031.59 (IN SE) INV: 1030.96 (OUT N) ST-17, SW-513 (4'X4') OPEN 2-SIDES (W/S) RIM:1033.00 INLET 1031.75 INV: 1028.83 (IN W) INV: 1028.63 (IN S) INV: 1028.53 (OUT E) ST-13, SW-501 T/C: 1042.27 INV: 1037.27 (OUT NW) ST-14, SW-501 T/C: 1042.27 INV: 1036.77 (IN SE) INV: 1037.15 (IN W) INV: 1036.67 (OUT N) CONNECT TO EXISTING, INTAKE INV: 1026.39 (IN W) 88 LF OF 15" RCP @ 0.50% 25 LF OF 15" RCP @ 1.86% 25 LF OF 15" RCP @ 2.00% 25 LF OF 18" RCP @ 1.30% 98 LF OF 15" RCP @ 0.96% 198 LF OF 8" HDPE @ 1.00% 108 LF OF 12" HDPE @ 1.00% 108 LF OF 12" HDPE @ 1.00% 88 LF OF 15" HDPE @ 1.00% 77 LF OF 15" HDPE @ 1.00% 100 LF OF 18" HDPE @ 0.70% 424 LF OF 18" HDPE @ 1. 9 0 % 132 LF OF 18" RCP @ 1.76% 124 LF O F 18" R C P @ 2 . 0 1 % 165 LF OF 24" RCP @ 1 . 3 0 % 25 LF OF 15" RCP @ 2.00% 21 5 LF O F 15 " R C P @ 1 . 2 0 % 165 LF OF 24" RCP @ 1 . 3 0 % 165 LF OF 24" RCP @ 1 . 3 0 % 165 LF OF 24" RCP @ 1 . 3 0 % ST-5, SW-401 RIM: 1047.17 INV: 1042.61 (OUT N) ST-10A, SW-401 RIM: 1046.14 INV: 1038.20 (IN S) INV: 1036.27 (IN E) INV: 1036.07 (OUT N) 57 LF O F 18 " R C P @ 0 . 4 0 % 48 LF OF 18" RCP @ 0.60% ST-11, SW-511 RIM: 1040.00 INV: 1035.84 (IN S) INV: 1035.74 (OUT N) 82 LF OF 18" RCP @ 0 . 6 0 % ST-11A, SW-401 RIM: 1041.05 INV: 1035.45 (IN S) INV: 1035.35 (OUT E) ST-12, SW-511 RIM: 1039.35 INV: 1034.86 (IN W) INV: 1034.76 (OUT E) 96 LF OF18" RCP @ 0 . 7 0 % 157 LF OF 15" HDPE @ 0.40% ST-10, 18" NYLOPLAST DRAIN BASIN W/ DOMED GRATE RIM: 1038.95 INV: 1036.90 (OUT W) ST-18, 18" NYLOPLAST DRAIN BASIN W/ DOMED GRATE RIM: 1042.50 INV: 1039.02 (OUT E) 58 LF OF 15" HDPE @ 1.90% 89 LF OF 15" HDPE @ 1.00 % ST-20, 18" NYLOPLAST DRAIN BASIN W/ DOMED GRATE RIM: 1041.65 INV: 1036.92 (IN W) INV: 1036.82 (OUT NE) ST-19, 18" NYLOPLAST DRAIN BASIN W/ DOMED GRATE RIM: 1042.42 INV: 1037.91 (IN W) INV: 1037.81 (OUT E) ST-21, 18" NYLOPLAST DRAIN BASIN W/ DOMED GRATE RIM: 1041.00 INV: 1035.79 (IN SW) INV: 1035.69 (OUT N) 10 2 LF O F 15 " HD P E @ 1 . 0 0 % ST-21A, 18" NYLOPLAST DRAIN BASIN W/ SOLID LID RIM: 1040.86 INV: 1034.67 (IN S) INV: 1034.57 (OUT N) 17 9 LF O F 15 " H D P E @ 1 . 0 0 % ST-21B, 18" NYLOPLAST DRAIN BASIN W/ SOLID LID RIM: 1038.62 INV: 1032.78 (IN S) INV: 1032.68 (OUT NW) 9 0 L F O F 1 5 " H D P E @ 1 . 2 1 % 103 LF O F 15" H D P E @ 1 . 0 0 % 15' Private Storm Sewer and Overland Flowage Easement 10' PUE 10' PUE 10' PUE 54' Public Ingress/Egress Easement 45' Public Ingress/Egress Easement 15' Private Overland Flowage Easement 15' Private Overland Flowage Easement 15' Private Overland Flowage Easement 10' PUE 10' PUE 20' Private Overland Flowage Easement 20' Private Overland Flowage Easement 45' Public Ingress/Egress Easement 1 0 5 L F O F 1 5 " H D P E @ 2 . 7 0 % 1E 1E 1E 2 BP=1033.27(ST) TP=1031.77(W) 2 BP=1033.65(ST) TP=1028.13(SAN) 2BP=1039.90(ST) TP=1033.11(SAN) 2 BP=1040.15(ST) TP=1031.19(SAN) 5' Public Gas Easement 5' Public Gas Easement 2 BP=1036.68(ST) TP=1031.63(SAN) 2 BP=1039.34(ST) TP=1037.84(W) 5' Public Gas Easement 15' Private Overland Flowage Easement BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m JA L RM B LB W 09 - 2 8 - 2 0 2 1 50 ' 12 1 . 0 4 7 6 C4 0 1 121.0476 C401 VI N T A G E E S T A T E S O F W A U K E E ST O R M S E W E R P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 10 / 2 6 / 2 1 11 / 1 1 / 2 1 12 / 0 9 / 2 1 03 / 3 0 / 2 2 RM B RM B LM W LM W 2345 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 1 \ 1 2 1 . 0 4 7 6 . 0 1 \ C A D D \ S P _ 1 2 1 0 4 7 6 _ S T R M . d w g LO R E N A W A S I O N , ST O R M S E W E R P L A N , 20 2 2 / 0 3 / 3 0 , 1: 5 5 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 50 1.PROVIDE PRIVATE STORM SEWER IMPROVEMENTS AS SHOWN ON THE PLANS AS PER CITY OF WAUKEE STANDARDS. A.CRITICAL CROSSING. CONTRACTOR TO VERIFY ALL CROSSINGS AND PROVIDE 18" MINIMUM SEPARATION. PROVIDE GASKETED STORM SEWER WITHIN 10' OF WATER MAIN. B.ALL STORM SEWER PIPE LENGTHS ARE MEASURED FROM CENTER OF STRUCTURE TO CENTER OF STRUCTURE AND INCLUDE FLARED END SECTION. C.ALL FOOTINGS FOR STORM SEWER STRUCTURES SHALL BE A MINIMUM 42 INCHES BELOW FINISHED GRADE. CONCRETE FILLET INSIDE INTAKES AS NECESSARY TO FLOW LINES. D.ALL STORM SEWER IS PRIVATE UNLESS OTHERWISE NOTED. E.4" SUMP SERVICE. 2. CRITICAL CROSSING. MAINTAIN MINIMUM 18" SEPARATION BETWEEN ALL OTHER UTILITIES. WHERE THE WATER MAIN IS LOCATED BELOW THE STORM SEWER, PROVIDE GASKETED JOINTS FOR RCP STORM SEWER LOCATION WITHIN 10 FEET OF CROSSING. AT CRITICAL CROSSING WHERE THE WATER MAIN IS LOCATED BELOW THE SANITARY SEWER, PROVIDE C900 SANITARY SEWER LOCATED WITHIN 10 FEET OF CROSSING. STORM SEWER CONSTRUCTION NOTES 1 (2620) 2 (2610) 3 (2600) 4 (2590) 5 (2580) 6 (2570) 7 (2560) 8 (2550) 9 (2540) 10 (2535) 11 (2525) 12 (2515) 13 (2505)14 (2495) 15 (2485) 16 (2475) 17 (2465) 18 (2455) 19 (2445) 20 (2435) 21 (2430) 22 (2420) 23 (2410) 24 (2400) 25 (2390) 26 (2395) 27 (2405) 28 (2415) 29 (2425)SE V I N T A G E L N SE V I N T A G E L N POOL CLUBHOUSE 2460 RISER 20 ' B u i l d i n g S e t b a c k 20' B u i l d i n g S e t b a c k 20' Bui l d i n g S e t b a c k BM500 BM501 100 101 103 ConcreteSE Tallgrass Lan e Co n c r e t e SE P a r k v i e w C r o s s i n g D r i v e Concrete SE Esker R i d g e D r i v e Con c r e t e SE E s k e r R i d g e D r i v e Concrete Sidewalk Planter Area Wood Fence Concrete Sidewalk Rim=1034.41 F.L.=1021.09 8" TRUSS NE F.L.=1021.09 8" TRUSS W Rim=1036.72 F.L.=1024.27 8" TRUSS E F.L.=1024.70 8" TRUSS W Rim=1049.00 F.L.=1036.36 8" TRUSS E Rim=1042.83 F.L.=1038.71 8" CMP W F.L.= 1038.52 18" RCP E Intake=1042.22 F.L.=1038.57 15" RCP N Intake=1042.22 F.L.=1039.05 15" RCP S Rim=1035.69 F.L.=1030.89 18" RCP W F.L.= 1030.89 18" RCP E Intake=1035.00 F.L.=1030.84 15" RCP N Intake=1034.98 F.L.=1031.53 15" RCP S Rim=1033.15 F.L.=1026.19 15" RCP W F.L.= 1026.19 18" RCP SE Intake=1032.45 F.L.=1028.30 15" RCP N Intake=1032.45 F.L.=1028.80 15" RCP S Intake=1033.18 F.L.=1026.14 24" RCP NE Intake=1032.41 F.L.=1025.49 24" RCP SW F.L.=1025.28 18" RCP NW F.L.=1025.14 24" RCP E Intake=1032.54 F.L.=1024.65 24" RCP W Intake=1034.10 F.L.=1030.05 15" RCP E Intake=1034.16 F.L.=1029.66 15" RCP W Intake=1039.00 F.L.=1034.95 15" RCP E Intake=1038.98 F.L.=1034.54 15" RCP W Intake=1044.51 F.L.=1040.30 15" RCP SW Intake=1044.57 F.L.=1040.25 15" RCP NE Concrete Sidewalk Rim=1045.40 F.L.=1040.61 15" RCP W F.L.= 1040.21 18" RCP SE Rim=1047.41 F.L.=1041.50 15" RCP SE F.L.= 1041.50 15" RCP SW Rim=1049.70 F.L.=1042.30 15" RCP NE F.L.= 1042.30 15" RCP SW Rim=1047.96 F.L.=1043.20 15" RCP NE Intake=1047.21 F.L.=1043.10 15" RCP NW Intake=1047.19 F.L.=1043.37 15" RCP SE Rim=1032.95 F.L.=1018.34 8" TRUSS N F.L.=1018.73 8" TRUSS SE F.L.=1018.14 8" TRUSS E F.L.=1018.14 8" TRUSS W Transformer MidAmerican Transformer MidAmerican N83°56'08"E 411. 6 4 ' M N83°41'41"E 411. 6 4 ' P C1 C2 C3 C4 C5 N37°28'27"E 62.82' M S37°14'00"W 62.82' P N0 ° 3 3 ' 1 9 " E 7 9 2 . 7 0 ' M N0 0 ° 1 8 ' 5 5 " E 7 9 2 . 7 0 ' P C 7 C9 C10 C8 C6 9 + 0 0 1 0 + 0 0 1 1 + 0 0 12 + 0 0 13 + 0 0 14 + 0 0 15 + 0 0 16+00 17+ 0 0 1 8 + 0 0 19 + 0 0 20+ 0 0 21+0022+0023+0023+58 BP S T A 9 + 0 0 . 0 0 PC S T A 1 0 + 5 0 . 5 5 PT STA 11+08.53 PC STA 14+44.35 P T S T A 1 5 + 8 9 . 8 8 P C S T A 1 6 + 5 2 . 9 5 PT STA 18+21.58 PC STA 19+51.96 PT S T A 2 0 + 4 6 . 2 1 EP S T A 2 3 + 5 8 . 0 3 10 4 6 10 4 5 10 5 0 10 4 8 10 4 7 10 4 5 10 4 7 10 4 9 10 4 8 104 5 104 4 10 4 6 1047 1048 1049 1 0 3 5 1 0 3 5 10 4 0 1045 1 0 3 3 1 0 3 3 1 0 3 4 1 0 3 4 1 0 3 6 10 3 6 1 0 3 7 10 3 7 1 0 3 8 10 3 8 1 0 3 9 10 3 9 1041 1042 1043 1044 1 0 4 7 104 7 10 4 6 104 7 1 0 4 7 1045 1044 1046 10 4 5 104610471 0 4 8 1 0 4 9 1035 1040 1034 10361037 1038 1039 1041 1042 1043 1044 1 0 4 7 10 4 7 10 4 6 10 4 5 1 0 4 6 10 4 7 1 0 4 5 10 4 9 1048 10 4 8 1049 1049 1049 10 4 8 10 4 8 10 4 7 10 4 7 10 4 7 1 0 4 1 1 0 4 2 1 0 4 3 1043 1044 1041 1040 10 4 1 10 4 2 104310441045 10 4 5 1 0 4 5 10 4 6 1046 1047 104 8 104 9 1043 1044 1043 1044 104 3 1 0 4 3 1 0 4 4 10 4 2 1 0 4 0 1041 1042 1044 1 0 4 7 1 0 4 0 1 0 4 0 1 0 4 1 1 0 4 2 1 0 4 3 1 0 4 4 10 4 5 1046 10 4 6 1040 15' Private Storm Sewer and Overland Flowage Easement 10' PUE 10' PUE 10' PUE 54' Public Ingress/Egress Easement 45' Public Ingress/Egress Easement 45' Private Ingress/Egress Easement 15' Private Overland Flowage Easement 15' Private Overland Flowage Easement 15' Private Overland Flowage Easement 20' Private Overland Flowage Easement 20' Private Overland Flowage Easement 10' PUE 10' PUE Ultimate Discharge Point 5' Public Gas Easement 5' Public Gas Easement 5' Public Gas Easement 1 0 4 0 1 0 4 1 5' Public Gas Easement BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m JA L RM B LB W 09 - 2 8 - 2 0 2 1 50 ' 12 1 . 0 4 7 6 C5 0 0 121.0476 C500 VI N T A G E E S T A T E S O F W A U K E E OV E R A L L G R A D I N G P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 10 / 2 6 / 2 1 11 / 1 1 / 2 1 12 / 0 9 / 2 1 03 / 3 0 / 2 2 RM B RM B LM W LM W 2345 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 1 \ 1 2 1 . 0 4 7 6 . 0 1 \ C A D D \ S P _ 1 2 1 0 4 7 6 _ G R A D . d w g LO R E N A W A S I O N , OV E R A L L G R A D I N G P L A N , 20 2 2 / 0 3 / 3 0 , 1: 5 6 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 50 GRADING NOTES 1.UTILITY WARNING: THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/ OR RECORDS OBTAINED. THE SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEY FURTHER DOES NOT WARRANT THAT THE UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED. 2.PROTECT EXISTING UTILITIES FROM CONSTRUCTION DAMAGE. ANY DAMAGE THAT OCCURS SHALL BE REPAIRED BY THE CONTRACTOR TO THE OWNERS SPECIFICATIONS WITHOUT ADDITIONAL COMPENSATION. 3.PRIOR TO GRADING, THE OWNER/ CONTRACTOR SHALL OBTAIN A COSESCO PERMIT. 4.GRADES SHOWN ARE FINISHED GRADE AND/OR TOP OF PAVING SLAB (GUTTER), UNLESS OTHERWISE NOTED. 5.CONTRACTOR SHALL PROVIDE SILT FENCE AROUND ALL STORM INTAKES AND WHERE SHOWN ON THE PLAN. SILT FENCE AROUND STORM INTAKES SHALL BE MAINTAINED UNTIL PAVING AND SEEDING/ SODDING ARE COMPLETE. 6. THE CONTRACTOR IS RESPONSIBLE FOR VERIFICATION AND COORDINATION OF ALL SITE UTILITIES AND IMPROVEMENTS WITH THE ARCHITECTURAL MECHANICAL/ ELECTRICAL/ PLUMBING SYSTEMS INCLUDING ROUTING, CRITICAL DIMENSIONS, CONNECTIONS, AND INVERT ELEVATIONS. 7.CONTRACTOR TO STRIP AND STOCKPILE TOPSOIL FROM ALL AREAS TO BE CUT OR FILLED. RESPREAD TO MEET SUDAS SPECIFICATION SECTION 2010 FOR TOPSOIL. 8. THE CONTRACTOR IS RESPONSIBLE FOR CLEANING DIRT AND DEBRIS FROM NEIGHBORING STREETS, DRIVEWAYS, AND SIDEWALKS CAUSED BY CONSTRUCTION ACTIVITIES. QUANTITIES EROSION CONTROL MEASURE SILT FENCE 3013 LF SEDIMENT BASKETS 24 EA TOTAL DISTURBED AREA 8.92 AC SOD 4.80 AC TYPE 4 URBAN TEMPORARY 8.92 AC EROSION CONTROL MIXTURE 4 (2590) 5 (2580) 6 (2570) 7 (2560) 8 (2550) 9 (2540) 10 (2535) 11 (2525) 12 (2515) 13 (2505)14 (2495) 15 (2485) 16 (2475) 17 (2465) 18 (2455) 19 (2445) 20 (2435) 21 (2430) 232425 26 (2395) 27 (2405) 28 (2415) 29 (2425)SE V I N T A G E L N SE V I N T A G E L N CLUBHOUSE 2460 BM501 103 Concrete SE Tallgrass Lan e Co n c r e t e SE P a r k v i e w C r o s s i n g D r i v e Concrete Sidewalk Rim=1034.41 F.L.=1021.09 8" TRUSS NE F.L.=1021.09 8" TRUSS W Rim=1036.72 F.L.=1024.27 8" TRUSS E F.L.=1024.70 8" TRUSS W Rim=1049.00 F.L.=1036.36 8" TRUSS E Rim=1042.83 F.L.=1038.71 8" CMP W F.L.= 1038.52 18" RCP E Intake=1042.22 F.L.=1038.57 15" RCP N Intake=1042.22 F.L.=1039.05 15" RCP S Rim=1035.69 F.L.=1030.89 18" RCP W F.L.= 1030.89 18" RCP E Intake=1035.00 F.L.=1030.84 15" RCP N Intake=1034.98 F.L.=1031.53 15" RCP S Rim=1033.15 F.L.=1026.19 15" RCP W F.L.= 1026.19 18" RCP SE Intake=1032.45 F.L.=1028.30 15" RCP NF.L.=1028.80 15" RCP S Intake=1033.18 F.L.=1026.14 24" RCP NE Intake=1032.41 F.L.=1025.49 24" RCP SW F.L.=1025.28 18" RCP NW F.L.=1025.14 24" RCP E Intake=1032.54 F.L.=1024.65 24" RCP W Intake=1034.10 F.L.=1030.05 15" RCP E Intake=1034.16 F.L.=1029.66 15" RCP W Intake=1039.00 F.L.=1034.95 15" RCP E Intake=1038.98 F.L.=1034.54 15" RCP W Rim=1032.95 F.L.=1018.34 8" TRUSS N F.L.=1018.73 8" TRUSS SE F.L.=1018.14 8" TRUSS E F.L.=1018.14 8" TRUSS W Transformer MidAmerican N83°56'08"E 411. 6 4 ' M N83°41'41"E 411. 6 4 ' P C1 C2 C3 N0 ° 3 3 ' 1 9 " E 7 9 2 . 7 0 ' M N0 0 ° 1 8 ' 5 5 " E 7 9 2 . 7 0 ' P C 7 C9 C6 13 + 0 0 14 + 0 0 15 + 0 0 16+00 17+ 0 0 1 8 + 0 0 19 + 0 0 20+ 0 0 21+0022+0023+0023+58 PC STA 14+44.35 P T S T A 1 5 + 8 9 . 8 8 P C S T A 1 6 + 5 2 . 9 5 PT STA 18+21.58 PC STA 19+51.96 PT S T A 2 0 + 4 6 . 2 1 EP S T A 2 3 + 5 8 . 0 3 10 5 0 10 4 8 10 4 7 10 4 5 10 4 7 10 4 9 1 0 3 5 1 0 3 5 10 4 0 1 0 3 3 1 0 3 3 1 0 3 4 1 0 3 4 1 0 3 6 10 3 6 1 0 3 7 10 3 7 1 0 3 8 10 3 8 1 0 3 9 10 3 9 1041 1042 1043 1044 1047 104 7 10 4 6 104 7 1 0 4 7 1045 1044 1046 FFE=1041.50 FFE=1042.75 FFE=1044.75 FFE=1047.00 FFE=1047.50 FFE=1047.50 FFE=1047.50 FFE=1047.50 FFE=1047.50 FFE=1047.00 FFE=1043.75 FFE=1043.25 FFE=1042.75 FFE=1042.25 FFE=1041.75 FFE=1040.65 FFE=1040.65 FFE=1046.00 FFE=1045.50 FFE=1045.00 FFE=1044.50 FFE=1041.551047.25 1047.251044.50 1045.60 OVERFLOW 1044.91 1043.35 1045.60 OVERFLOW 1047.30 1046.75 1044.50 1046.751045.60 OVERFLOW 104 4 . 2 6 104 5 . 7 5 104 4 . 7 5 1044.25 1042.761043.26 1045.25 104 4 . 2 5 1 0 4 3 . 5 0 104 3 . 0 0 1042.50 1041.00 1040.511042.00 1041.50 1040.01 1038.68 1040.15 1037.10 1038.55 1040.25 1038.80 104 1 . 2 5 1039.78 104 2 . 5 0 104 1 . 0 1 1043.03 104 4 . 5 0 1046.00 104 5 . 9 7 1045.78 1047.25 1031.75 1041.00 1042.50 OVERFLOW 1040.00 1041.00 OVERFLOW 1041.25 1038.95 1045.50 OVERFLOW 1039.35 104 5 1046 10471 0 4 8 1 0 4 9 1035 1040 1034 1036 1037 1038 1039 1041 1042 1043 1044 10 4 7 10 4 6 10 4 5 1 0 4 6 10 4 7 10 4 5 10 4 7 10 4 7 1 0 4 1 1 0 4 2 1 0 4 3 1043 1044 1041 1040 10 4 1 10 4 2 104310441045 10 4 5 1 0 4 5 10 4 2 1 0 4 0 1041 1042 1044 1 0 4 7 1 0 4 0 1 0 4 0 1 0 4 1 1 0 4 2 1 0 4 3 1044 10 4 5 1046 10 4 6 1040 1040.65 1040.65 1040.65 1040.65 1040.65 1040.65 1040.65 1040.65 1041.75 1041.751041.75 1041.75 1042.75 1042.75 1042.751042.75 1043.25 1043.25 1043.25 1043.25 1043.75 1043.75 1044.50 1044.50 1044.75 1044.75 104 5 . 5 0 1045.50 1045.90 1045.90 1047.00 1047.00 1047.00 1047.00 1047.00 1047.00 1047.50 1047.501047.50 1047.50 1047.50 1047.501047.50 1047.50 1047.50 1047.50 1047.50 1047.50 1047.50 1047.50 1047.50 1047.50 1047.50 1047.50 1047.50 10 4 7 . 0 0 1047.00 1047.00 1047.00 1044.751044 . 7 5 1044.75 1044.75 1042.75 1042.75 104 2 . 7 5 1042.75 1041.50 1041.50 1041.50 1041.50 1046.00 1046.00 1046.00 1046.00 1045.50 1045.50 1045.50 1045.50 1045.00 1045.00 1045.00 1045.00 1044.50 1044.50 1044.50 1044.50 1041.55 1041.411041.551041.55 1041.55 15' Private Storm Sewer and Overland Flowage Easement 10' PUE 10' PUE 45' Public Ingress/Egress Easement 45' Private Ingress/Egress Easement 15' Private Overland Flowage Easement 15' Private Overland Flowage Easement 20' Private Overland Flowage Easement 20' Private Overland Flowage Easement Ultimate Discharge Point 1037.68 1040.8 6 41.1' 2 0 . 5 ' 2 1 . 4 ' 14.4' 13.7' 19.3 ' 22.2' 21.4' 21.4' - 5 . 6 3 % - 8 . 6 0 % - 6 . 1 1 % - 6 . 0 2 % -6 . 7 1 % -5. 9 1 % -5.19% -8.05% -7.35% -6.22% -5.9 7 % - 6 . 0 0 % - 7 . 0 1 % -5 . 7 1 % -5 . 3 9 % -4 . 5 8 % -3 . 7 6 % - 4 . 4 0 % -5 . 0 7 % - 5 . 8 9 % -2.8 7 % -4.13% -5.53% -7.64% -6.81% -8.25% -2 . 0 4 % - 2 . 0 3 % -2 . 0 4 % -2 . 0 3 % -2. 1 0 % -4 . 5 0 % 2. 0 0 % -2.0 0 % -6 . 7 5 % -1 5 . 2 4 % -3.16% -2.95% -2.80% -4.00% -2.00% -2.00% -2.00% -2.00% -2.00% -2. 0 0 % - 2 . 0 0 % -2.00% -2.00% -2.00% -2.00% -2. 0 0 % -2 . 0 0 % - 2 . 0 0 % - 2 . 0 0 % - 2 . 0 0 % -2 . 0 2 % -2 . 0 2 % -2 . 0 2 % -21 . 1 9 % -2.02% -2.00% -2.00% 1047.00 1047.00 1047.00 1047.00 1047.50 1047.50 1047.50 1047.50 1047.50 1047.50 1047.50 1047.50 1047.50 1047.50 1047.00 1047.00 104 4 . 7 5 104 4 . 7 5 1042.75 1042.75 1041.50 1041.50 1040.65 1040.65 1040.651040.65 1041.751041.75 1042.25 1042.25 1042.25 1042.25 1042.25 1042.25 1042.751042.75 1043.25 1043.25 1041.55 -2 . 0 5 % -2 . 0 5 % -2 . 0 1 % -2 . 0 0 % -2 . 0 1 % -2. 0 0 % -3. 1 5 % -4.34% 100-YR ELEV =1044.82 100-YR ELEV =1044.82 100-YR ELEV =1043.98 100-YR ELEV=1039.27 100-YR ELEV=1040.25 100-YR ELEV =1039.45 100-YR ELEV=1039.20 100-YR ELEV=1041.32 1034.75 OVERFLO W 100-YR ELEV=1032.13 1046.75 - 2 . 0 5 % FG=1046.00 FG=1046.00 FG=1042.75 FG=1042.75 -2.21% - 2 . 0 2 % -2 . 1 0 % -2.00% 1043.00FG 1043.50TW 1043.00FG 1044.00TW1043.08FG 1044.50TW 1043.06FG 1046.00TW 1043.60FG 1046.00TW 1046.00FG 1046.50TW 1045.00FG 1046.29TW 1041.55 1039.24TC OVERFLOW 1046.85 OVERFLOW 1045.02 OVERFLOW 5' Public Gas Easement 5' Public Gas Easement 5' Public Gas Easement 1033.37 1033.25 1034.96 ??? 1036.89 ??? 1050.91 1040. 8 4 1041.98 1039.84 1 0 3 8 . 8 2 1036.85 1035.13 1032.17 1038.63 10' TYP 1039. 8 1 10 3 7 . 5 5 1035.70 1033.80 10' TYP OVERFLOW ROUTE OVERFLOW ROUTE OVERFLOW ROUTE OVERFLOW ROUTE OVERFLOW ROUTE OVERFLOW ROUTE OVERFLOW ROUTE OVERFLOW ROUTE 1 0 4 0 1 0 4 1 1 0 4 1 . 5 5 1 0 4 1 . 5 5 1040.76 OVERFLOW 1041.38 1041.38 OVERFLOW ROUTE OVERFLOW ROUTE 15' Private Overland Flowage Easement 5' Public Gas Easement 1041.55 1040.65 OVERFLOW BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m JA L RM B LB W 09 - 2 8 - 2 0 2 1 30 ' 12 1 . 0 4 7 6 C5 0 1 121.0476 C501 VI N T A G E E S T A T E S O F W A U K E E DE T A I L E D G R A D I N G P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 10 / 2 6 / 2 1 11 / 1 1 / 2 1 12 / 0 9 / 2 1 03 / 3 0 / 2 2 RM B RM B LM W LM W 2345 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 1 \ 1 2 1 . 0 4 7 6 . 0 1 \ C A D D \ S P _ 1 2 1 0 4 7 6 _ G R A D . d w g LO R E N A W A S I O N , DE T A I L E D G R A D I N G P L A N , 20 2 2 / 0 3 / 3 0 , 1: 5 6 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 30 1 (2620) 2 (2610) 3 (2600) 4 (2590) 5 (2580) 6 (2570) 7 (2560) (2550) 18 (2455) 19 (2445) 20 (2435) 21 (2430) 22 (2420) 23 (2410) 24 (2400) 25 (2390) 26 (2395) 27 (2405) 28 (2415) 29 (2425)SE V I N T A G E L N SE V I N T A G E L N BM500 100 101 SE P a r k v i e w C r o s s i n g D r i v e Concrete SE Esker R i d g e D r i v e Con c r e t e SE E s k e r R i d g e D r i v e Concrete Sidewalk Planter Area Wood Fence Intake=1039.00 F.L.=1034.95 15" RCP E Intake=1038.98 F.L.=1034.54 15" RCP W Intake=1044.51 F.L.=1040.30 15" RCP SW Intake=1044.57 F.L.=1040.25 15" RCP NE Concrete Sidewalk Rim=1045.40 F.L.=1040.61 15" RCP W F.L.= 1040.21 18" RCP SE Rim=1047.41 F.L.=1041.50 15" RCP SE F.L.= 1041.50 15" RCP SW Rim=1049.70 F.L.=1042.30 15" RCP NE F.L.= 1042.30 15" RCP SW Rim=1047.96 F.L.=1043.20 15" RCP NE Intake=1047.21 F.L.=1043.10 15" RCP NW Intake=1047.19 F.L.=1043.37 15" RCP SE Transformer MidAmerican Transformer MidAmerican C3 C4 C5 N37°28'27"E 62.82' M S37°14'00"W 62.82' P N0 ° 3 3 ' 1 9 " E 7 9 2 . 7 0 ' M N0 0 ° 1 8 ' 5 5 " E 7 9 2 . 7 0 ' P C10 C8 9 + 0 0 1 0 + 0 0 1 1 + 0 0 12 + 0 0 13 + 0 0 14 + 0 0 19 + 0 0 20+ 0 0 21+0022+0023+0023+58 BP S T A 9 + 0 0 . 0 0 PC S T A 1 0 + 5 0 . 5 5 PT STA 11+08.53 PC STA 19+51.96 PT S T A 2 0 + 4 6 . 2 1 EP S T A 2 3 + 5 8 . 0 3 10 4 6 10 4 5 10 4 7 10 4 8 104 5 104 4 10 4 6 1047 1048 1049 10 4 0 1045 10 3 9 1041 1042 1043 1044 FFE=1047.50 FFE=1047.50 FFE=1047.50 FFE=1047.00 FFE=1047.00 FFE=1048.00 FFE=1049.00 FFE=1049.50 FFE=1045.90 FFE=1045.50 FFE=1044.75 FFE=1044.50 FFE=1043.75 FFE=1043.25 FFE=1042.75 FFE=1042.25 FFE=1046.00 FFE=1045.50 FFE=1045.00 FFE=1044.50 1047.251044.50 1045.60 OVERFLOW 1047.30 1046.75 1044.50 1046.751045.60 OVERFLOW 1046.75 1044.50 1047.75 1048.75 104 4 . 2 6 104 5 . 7 5 104 4 . 7 5 1044.25 1042.761043.26 1045.25 1043.76 1043.01 1042 . 7 5 104 4 . 2 5 1 0 4 3 . 5 0 1042.05 104 3 . 0 0 1042.50 1041.00 1040.511042.00 1041.50 1040.01 1042 . 4 2 1041.65 1041.00 1042 . 5 0 1043 . 0 5 OVE R F L O W 104 3 . 1 5 OVE R F L O W 1042.70 OVERFLOW 1042.50 OVERFLOW 1041.25 1038.95 10 4 7 10 4 7 10 4 6 10 4 5 1 0 4 6 1 0 4 5 10 4 9 1048 10 4 8 1049 1049 1049 10 4 8 10 4 8 10 4 7 10 4 7 10 4 7 1 0 4 2 1 0 4 3 1043 1044 1041 1040 10 4 1 10 4 2 104310441045 10 4 5 1 0 4 5 10 4 6 1046 1047 104 8 104 9 1043 1044 1043 1044 104 3 1 0 4 3 1 0 4 4 10 4 2 10 4 6 1041.751041.75 1042.75 1042.75 1042.751042.75 1043.25 1043.25 1043.25 1043.25 1043.75 1043.75 1043.75 1043.75 1044.50 1044.50 1044.50 1044.50 1044.75 1044.75 1044.75 1044.75 104 5 . 5 0 1045.50 1045.50 1045.50 1045.90 1045.90 1045.90 1045.90 1049.501049.50 1049.50 1049.50 1049.00 1049.00 1049.001049.00 1048.00 1048.00 1048.00 1048.00 1047.001047.00 1047.00 1047.00 1047.00 1047.00 1047.00 1047.00 1047.50 1047.501047.50 1047.50 1047.50 1047.501047.50 1047.50 1047.50 1046.00 1046.00 1046.00 1046.00 1045.50 1045.50 1045.50 1045.50 1045.00 1045.00 1045.00 1045.00 1044.50 1044.50 1044.50 1044.50 1041.411041.551041.55 10' PUE 10' PUE 10' PUE 54' Public Ingress/Egress Easement 45' Private Ingress/Egress Easement 15' Private Overland Flowage Easement 15' Private Overland Flowage Easement 20' Private Overland Flowage Easement 10' PUE 10' PUE 1040.8 6 13.7' 19.3 ' 21 . 4 ' 1 9 . 5 ' 3 0 . 0 ' 22.9' 22.2' 21.4' -7.35% -6.22% -5.9 7 % - 6 . 0 0 % - 7 . 0 1 % -5 . 7 1 % -5 . 3 9 % -4 . 5 8 % -3 . 7 6 % - 4 . 4 0 % -5 . 0 7 % - 5 . 8 9 % -5.53% -7.64% -6.81% -8.25% -9.50% -7.07% -3.00% -2 . 0 4 % -2 . 5 0 % -2 . 0 4 % -2 . 0 3 % -2 . 3 6 % -9 . 0 7 % -2.35% -2.10%-2.00% -2.75% -2.0 2 % -3.3 5 % -2. 1 0 % -4 . 5 0 % 2. 0 0 % -2.00% -2.00% -2.00% -2.00% -2.00% -2.00% -2.00% -2 . 0 0 % -2 . 0 0 % -2 . 0 0 % - 2 . 0 0 % - 2 . 0 0 % -2.00% -2.00% -2.00% -2 . 0 2 % -2 . 0 2 % -2 . 0 2 % -21 . 1 9 % 4.0' -2.00% -2.00% -2.00% -2.00% 1049 . 5 0 1049.50 1048.00 1048.00 1047.00 1047.00 1047.00 1047.00 1047.50 1047.50 1047.50 1047.50 1042.25 1042.25 1042.25 1042.25 1042.25 1042.25 1042.751042.75 1043.25 1043.25 1043.75 1043.75 -2.04% 1045.90 1045.90 1045.50 1045.50 1044.50 1044.50 1044.75 1044.75 -2 . 0 5 % -2 . 0 5 % 100-YR ELEV =1045.37 100-YR ELEV =1044.82 100-YR ELEV =1044.82 100-YR ELEV =1045.00 100-YR ELEV=1039.27 100-YR ELEV=1042.92 100-YR ELEV=1042.70 100-YR ELEV=1041.93 100-YR ELEV=1041.32 -2.21% - 2 . 0 2 % -2.00% 1046.00FG 1046.50TW 1045.02 OVERFLOW 5' Public Gas Easement 5' Public Gas Easement SE E S K E R R I D G E D R I V E 5' Public Gas Easement 1047.99 1048.31 1047.20 1045.19 1044.37 1040. 8 4 1041.98 1039.84 1 0 3 8 . 8 2 1038.63 10' TYP 1039. 8 1 10 3 7 . 5 5 18.0 ' R40.0' R4 0 . 0 ' 18.0 ' OVERFLOW ROUTE OVERFLOW ROUTE OVERFLOW ROUTE OVERFLOW ROUTE 1 0 4 1 . 5 5 1 0 4 1 . 5 5 1040.76 OVERFLOW OVERFLOW ROUTE 5' Public Gas Easement BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m JA L RM B LB W 09 - 2 8 - 2 0 2 1 30 ' 12 1 . 0 4 7 6 C5 0 2 121.0476 C502 VI N T A G E E S T A T E S O F W A U K E E DE T A I L E D G R A D I N G P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 10 / 2 6 / 2 1 11 / 1 1 / 2 1 12 / 0 9 / 2 1 03 / 3 0 / 2 2 RM B RM B LM W LM W 2345 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 1 \ 1 2 1 . 0 4 7 6 . 0 1 \ C A D D \ S P _ 1 2 1 0 4 7 6 _ G R A D . d w g LO R E N A W A S I O N , DE T A I L E D G R A D I N G P L A N , 20 2 2 / 0 3 / 3 0 , 1: 5 6 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 30 1 (2620) 2 (2610) 3 (2600) 4 (2590) 5 (2580) 6 (2570) 7 (2560) 8 (2550) 9 (2540) 10 (2535) 11 (2525) 12 (2515) 13 (2505)14 (2495) 15 (2485) 16 (2475) 17 (2465) 18 (2455) 19 (2445) 20 (2435) 21 (2430) 22 (2420) 23 (2410) 24 (2400) 25 (2390) 26 (2395) 27 (2405) 28 (2415) 29 (2425)SE V I N T A G E L N SE V I N T A G E L N POOL CLUBHOUSE 2460 RISER 20 ' B u i l d i n g S e t b a c k 20' B u i l d i n g S e t b a c k 20' Bui l d i n g S e t b a c k BM500 BM501 100 101 103 ConcreteSE Tallgrass Lan e Co n c r e t e SE P a r k v i e w C r o s s i n g D r i v e Concrete SE Esker R i d g e D r i v e Con c r e t e SE E s k e r R i d g e D r i v e Concrete Sidewalk Planter Area Wood Fence Concrete Sidewalk Rim=1034.41 F.L.=1021.09 8" TRUSS NE F.L.=1021.09 8" TRUSS W Rim=1036.72 F.L.=1024.27 8" TRUSS E F.L.=1024.70 8" TRUSS W Rim=1049.00 F.L.=1036.36 8" TRUSS E Rim=1042.83 F.L.=1038.71 8" CMP W F.L.= 1038.52 18" RCP E Intake=1042.22 F.L.=1038.57 15" RCP N Intake=1042.22 F.L.=1039.05 15" RCP S Rim=1035.69 F.L.=1030.89 18" RCP W F.L.= 1030.89 18" RCP E Intake=1035.00 F.L.=1030.84 15" RCP N Intake=1034.98 F.L.=1031.53 15" RCP S Rim=1033.15 F.L.=1026.19 15" RCP W F.L.= 1026.19 18" RCP SE Intake=1032.45 F.L.=1028.30 15" RCP N Intake=1032.45 F.L.=1028.80 15" RCP S Intake=1033.18 F.L.=1026.14 24" RCP NE Intake=1032.41 F.L.=1025.49 24" RCP SW F.L.=1025.28 18" RCP NW F.L.=1025.14 24" RCP E Intake=1032.54 F.L.=1024.65 24" RCP W Intake=1034.10 F.L.=1030.05 15" RCP E Intake=1034.16 F.L.=1029.66 15" RCP W Intake=1039.00 F.L.=1034.95 15" RCP E Intake=1038.98 F.L.=1034.54 15" RCP W Intake=1044.51 F.L.=1040.30 15" RCP SW Intake=1044.57 F.L.=1040.25 15" RCP NE Concrete Sidewalk Rim=1045.40 F.L.=1040.61 15" RCP W F.L.= 1040.21 18" RCP SE Rim=1047.41 F.L.=1041.50 15" RCP SE F.L.= 1041.50 15" RCP SW Rim=1049.70 F.L.=1042.30 15" RCP NE F.L.= 1042.30 15" RCP SW Rim=1047.96 F.L.=1043.20 15" RCP NE Intake=1047.21 F.L.=1043.10 15" RCP NW Intake=1047.19 F.L.=1043.37 15" RCP SE Rim=1032.95 F.L.=1018.34 8" TRUSS N F.L.=1018.73 8" TRUSS SE F.L.=1018.14 8" TRUSS E F.L.=1018.14 8" TRUSS W Transformer MidAmerican Transformer MidAmerican N83°56'08"E 411. 6 4 ' M N83°41'41"E 411. 6 4 ' P C1 C2 C3 C4 C5 N37°28'27"E 62.82' M S37°14'00"W 62.82' P N0 ° 3 3 ' 1 9 " E 7 9 2 . 7 0 ' M N0 0 ° 1 8 ' 5 5 " E 7 9 2 . 7 0 ' P C 7 C9 C10 C8 C6 9 + 0 0 1 0 + 0 0 1 1 + 0 0 12 + 0 0 13 + 0 0 14 + 0 0 15 + 0 0 16+00 17+ 0 0 1 8 + 0 0 19 + 0 0 20+ 0 0 21+0022+0023+0023+58 BP S T A 9 + 0 0 . 0 0 PC S T A 1 0 + 5 0 . 5 5 PT STA 11+08.53 PC STA 14+44.35 P T S T A 1 5 + 8 9 . 8 8 P C S T A 1 6 + 5 2 . 9 5 PT STA 18+21.58 PC STA 19+51.96 PT S T A 2 0 + 4 6 . 2 1 EP S T A 2 3 + 5 8 . 0 3 10 4 6 10 4 5 10 5 0 10 4 8 10 4 7 10 4 5 10 4 7 10 4 9 10 4 8 ● ● ● ● ●●●●●●●●●●●● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●●●●● ● ● ● ● ● ●● ● ● ● ● ● ●● ● ● ● 104 5 104 4 10 4 6 1047 1048 1049 1 0 3 5 1 0 3 5 10 4 0 1045 1 0 3 3 1 0 3 3 1 0 3 4 1 0 3 4 1 0 3 6 10 3 6 1 0 3 7 10 3 7 1 0 3 8 10 3 8 1 0 3 9 10 3 9 1041 1042 1043 1044 1 0 4 7 104 7 10 4 6 104 7 1 0 4 7 1045 1044 1046 10 4 5 104610471 0 4 8 1 0 4 9 1035 1040 1034 10361037 1038 1039 1041 1042 1043 1044 1 0 4 7 10 4 7 10 4 6 10 4 5 1 0 4 6 10 4 7 1 0 4 5 10 4 9 1048 10 4 8 1049 1049 1049 10 4 8 10 4 8 10 4 7 10 4 7 10 4 7 1 0 4 1 1 0 4 2 1 0 4 3 1043 1044 1041 1040 10 4 1 10 4 2 104310441045 10 4 5 1 0 4 5 10 4 6 1046 1047 104 8 104 9 1043 1044 1043 1044 104 3 1 0 4 3 1 0 4 4 10 4 2 1 0 4 0 1041 1042 1044 1 0 4 7 1 0 4 0 1 0 4 0 1 0 4 1 1 0 4 2 1 0 4 3 1 0 4 4 10 4 5 1046 10 4 6 1040 CONSTRUCTION ENTRANCE STAGING AREA WASHOUT AREA TOPSOIL STOCKPILE ● ● ● ● ● ● ● PRIVATE STORM SEWER DISCHARGE LOCATION TO AN UNNAMED TRIBUTARY OF FOX CREEK. ●●●● ● LIMIT OF DISTURBANCE 1 0 4 0 1 0 4 1 BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m JA L RM B LB W 09 - 2 8 - 2 0 2 1 50 ' 12 1 . 0 4 7 6 C5 0 3 121.0476 C503 VI N T A G E E S T A T E S O F W A U K E E ER O S I O N C O N T R O L P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 10 / 2 6 / 2 1 11 / 1 1 / 2 1 12 / 0 9 / 2 1 03 / 3 0 / 2 2 RM B RM B LM W LM W 2345 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 1 \ 1 2 1 . 0 4 7 6 . 0 1 \ C A D D \ S P _ 1 2 1 0 4 7 6 _ G R A D . d w g LO R E N A W A S I O N , ER O S I O N C O N T R O L P L A N , 20 2 2 / 0 3 / 3 0 , 1: 5 6 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 50 Post Spacing (5'-0" max.) Post Spacing (5'-0" max.) Variable (20'-0" for a normal 10'-0" wide ditch.) TYPICAL SILT FENCE DITCH CHECK Fore s l o p e Bac k s l o p e 1 2" min. 20" min. ATTACHMENT TO POST Fabric Post Wire or Cable Ties Insert 12 inches of fabric a minimum of 6 inches deep (fabric may be folded below the ground line). Reduce post spacing to 5'-0" at water concentration areas, or as required to adequately support fence. 1 2 24" 36" 8'-0" Spacing DETAILS OF SILT FENCE ON LONGITUDINAL SLOPES 1 2 Ground Line Fabric See plans for spacing. (Profile View) TYPICAL SILT FENCE INSTALLATION ON LONGITUDINAL SLOPES 1 1 'T' Steel Fence Post 4'-0" min. Ground line Fabric Flow SILT FENCE 200'-0" max. length per section (600'-0" if slope is flatter than 5%) (Plan View) TYPICAL SILT FENCE INSTALLATION ON LONGITUDINAL SLOPES Ground ContoursInstall parallel to ground contour. Install "J-hook" at each end of an individual section of silt fence. 13 + 0 0 22+00 1045.90 1046.00 -4 . 5 8 % -3 . 7 6 % -6.81% 4.6%3.60% 4.4% 1. 6 % -1.20% -1.20% 1045.31 1045.06 104 4 . 8 2 104 5 . 2 6 1045.37 1045.48 1045.23 1045.17TC 1044.92 1044.89TC 1045. 0 8 1044 . 8 2 1044 . 9 0 1045 . 0 0 T C 1044 . 7 5 1044 . 9 6 1044 . 8 8 1045 . 2 5 1 0 4 4 . 8 8 1 0 4 5 . 1 0 T C 1 0 4 4 . 8 5 104 5 . 1 8 104 4 . 9 6 1. 6 % 1045.02 OVERFLOW 1.2% 1.2% 1044.64 1. 6 % -1.30% 1. 6 % 1. 6 % 3.5% 1. 6 % 5.8%3.60% SE E s k e r R i d g e D r i v e 1 0 + 0 0 PC S T A 1 0 + 5 0 . 5 5 104 9 4.0' - 1 . 3 9 % - 1 . 4 0 % -1.0 0 % - 1 . 3 5 % -5.5 0 % - 1 . 4 0 % -5.5 5 % -1.00 % 1049.74 1049.79 1049 . 8 8 1049.83 1049.76 1049.81 1049.42 1049.52 1049.48 1049.38 1049.41TC 1050.02TC 1049.52 (1049.15) (1049.12) (1049.00) (1048.98) (1049.18) 1049.16 1049.45TC 1049.20 SE E S K E R R I D G E D R I V E - 2 . 0 0 % 1049.66TC 1049.16 18.0 ' -5.5 5 % - 1 . 8 0 % -1.00 % -5.5 0 % 1049.72 1049.77 1049.84 1049.79 R40.0' R4 0 . 0 ' 1049.50 1049.51 18.0 ' - 1 . 4 0 % -1.0 0 % - 1 . 4 0 % - 1 . 8 0 % -1.00 % 1 8 + 0 0 PT STA 18+21.58 1041.50 1040.15 1 0 4 0 1040.65 1041.75 1041.75 1041.55 1041.41 1042.25 -1.80% -5 . 0 0 % -6 . 6 0 % -0.80% -0.80% -4.53% -4.53% -1.86% -1.32% -1.46% -1.95 % 1039.04 1040.25 1040.03 1039.91 1040.16 1040.28 1040.61TC 1040.65 1040.32 1040.41TC 1039.31 1039.62 1040.56 1040.90 1040.50TC1040.48 1039.26 1039.29TC 1039.79 1040.36TC 1040.33 1040.81TC 1040.25 1040.50 1040.46 1040.16 1040.36 1040.11 1040.24TC 1039.99 1039.56TC 1039.34 1040.25 1039.04 1039.66 1039.68 1039.75 1039.71 1039.64 -1.80% -1.80% -1 . 2 8 % -1.32% 1. 0 % -1.60 % - 0 . 4 0 % 1039.54 1040.85 1040.84 1 0 4 0 1 0 4 1 0. 6 % -0.8% -6 . 6 0 % -1.80% -5 . 0 0 % 1040.69 1040.76 1040.66TC 1040.73TC 1040.41 1040.48 -0.80%-1 . 4 0 % 1040.76 OVERFLOW 1041.38 1041.38 -1.0 0 % -1.00 % - 1 . 7 5 % 1039.25TC 1039.34TC 1039.09 1039.00 -1.8 0 % 0 . 0 0 % -0.80% -0 . 7 8 % -1 . 3 5 % -1 . 4 0 % 1041.411041.55 1 0 4 1 . 5 5 1 0 4 1 . 5 5 1041.471041.47 1 0 4 1 . 3 5 1 0 4 1 . 3 5 1041.30 1041 . 2 5 1041.31 1041 . 2 5 1041.401041.40 1041.38 -1 . 0 0 % -1 . 0 0 % - 0 . 7 % 0.00% 0.00% -1 . 4 0 % -1 . 4 0 % - 1 . 0 % 0.00% 0.00% CLUBHOUSE 1039.35 1040 1041.55 1043.00FG 1043.50TW 1040.65 . 1041.05 1040.98 10 4 0 . 5 8 1041.45 1041.55 1041.40 10 4 0 . 5 3 104 0 . 6 0 . 1041.05 1040.981041 . 4 0 1041.45 1041.55 -1 . 0 0 % -0.00% -0. 7 0 % 0.00%-1 . 0 0 % -1 . 4 0 % -1 . 4 0 % 0.00% -0.00% -1.0 0 % -1 . 0 0 % -1.40% -1 . 0 0 % -1.40% -1.7 0 % 1040.65 OVERFLOW BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m JA L RM B LB W 09 - 2 8 - 2 0 2 1 10 ' 12 1 . 0 4 7 6 C5 0 4 121.0476 C504 VI N T A G E E S T A T E S O F W A U K E E IN T E R S E C T I O N A N D S I D E W A L K D E T A I L S WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 10 / 2 6 / 2 1 11 / 1 1 / 2 1 12 / 0 9 / 2 1 03 / 3 0 / 2 2 RM B RM B LM W LM W 2345 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 1 \ 1 2 1 . 0 4 7 6 . 0 1 \ C A D D \ S P _ 1 2 1 0 4 7 6 _ G R A D . d w g LO R E N A W A S I O N , IN T E R S E C T I O N A N D S I D E W A L K D E T A I L S , 20 2 2 / 0 3 / 3 0 , 1: 5 7 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 10 DETAIL 1/C504 DETAIL 2/C504 DETAIL 3/C504 DETAIL 4/C504 DETAIL 5/C504 Kettlesto n e R i d g e P l a t 3 Kettlesto n e R i d g e P l a t 2 9 10 4 9 Kettlesto n e R i d g e Plat 1 BM500 101 102 103 343,965 SF 7.90 AC Lot 1 1 (2620) 2 (2610) 3 (2600) 4 (2590) 5 (2580) 6 (2570) 7 (2560) 8 (2550) 9 (2540) 10 (2535) 11 (2525) 12 (2515) 13 (2505)14 (2495) 15 (2485) 16 (2475) 17 (2465) 18 (2455) 19 (2445) 20 (2435) 21 (2430) 22 (2420) 23 (2410) 24 (2400) 25 (2390) 26 (2395) 27 (2405) 28 (2415) 29 (2425)SE V I N T A G E L N SE V I N T A G E L N POOL CLUBHOUSE 2460 RISER 20' Bu i l d i n g S e t b a c k 20' Bui l d i n g S e t b a c k 3-CR 1-PN 10-PO 3-MP 2-UP 1-MP 9-VL 3-CR 11-SB 3-JU 7-AB 3-JU 1-PI 3-SR 1-GB 3-SN 5-HY 18-FO 3-MP 15-PF 3-CC 1-GB10-CA 1-AC 11-PF 3-PG 1-PI 1-AC 1-AG 1-AC 1-SR 9-HY 3-SN 12-AB 2-AG 5-MJ 13-SB 2-GL 8-VL 2-GL 3-PT 3-PT 3-JU 1-PN 2-CR 10-PF 1-CR 13-CA 1-UP 1-GB 1-CR 7-CC 3-PT 1-CR 9-SB 1-PI 2-GB 2-MJ 1-UP 1-UP 4-SN 1-AC 1-PN 6-JS 2-QU 12-HY 1-SR 3-PC 1-PI 2-MJ 1-SR 9-SB 1-AC 1-SR 10-PF 2-GL 5-VL 2-SR 3-MJ 5-HK 9-CA 1-GL 1-PN 3-OV 3-CR 3-JU 2-MJ 1-PI 1-CR 1-CR 12-SB 9-FO 13-AB 2-TA 7-CC 6-JS 2-QU 3-MJ 5-HK 9-CA 1-PN 3-AG 9-PF 3-PC 9-FO 1-QU 1-AG 1-AG 15-PO 12-SB 1-PI 3-MJ 1-PS 1-PS 9-HY 3-SN 11-HK 7-CA1-PN 6-JS 3-MP1-PS 3-OV 2-CR 15-PO 3-CR 9-SB 9-PF 3-PC 1-PI 5-HY 2-MJ 2-CT 3-MJ 1-CT 5-VL 9-HK 2-MJ 1-CT 12-CA 1-PN 1-AG 1-TA 3-CC 3-PG 2-AG 11-SB 3-SR 2-TA 15-FO 11-CA 1-PN 6-JS2-CO 1-SR 1-SR 9-PO 9-PF 1-CO 6-PC 9-FO 3-VL 3-MJ 1-UP 2-PI 11-FO 3-VL 3-MJ 9-PF 1-CO 1-SR 2-CO 6-PT 1-SR 9-PO 1-PN 3-AG 1-PI 1-MP 11-AB 1-QB 3-SN 11-SB 11-CA 15-HK 2-QB 3-JU 2-MP 3-JS 11-HK 5-CC 1-TA 3-MJ 2-TA 2-MJ 1-TA 5-PO 1-PN 3-PC 11-SB 3-AG 1-CR 1-CT 1-CR 1-PI 3-VL 9-FO 1-CT 12-HY 3-JU 3-SR 7-CA 1-CT 3-MJ 1-PS 1-PS 5-VL 1-PS 11-SB 11-HY 1-PN 1-AG2-AG 5-PG 1-QB 9-PF 3-SN 2-QB 1-PI 3-JS 5-HY 5-CA 1-AC 2-GL 1-GL 1-UP 1-UP 1-UP 1-CO 1-CO 1-TA 1-TA 1-PS 1-PS 1-GB 1-PS BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m JA L RM B LB W 09 - 2 8 - 2 0 2 1 60 ' 12 1 . 0 4 7 6 C6 0 0 121.0476 C600 VI N T A G E E S T A T E S O F W A U K E E PL A N T I N G P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 10 / 2 6 / 2 1 11 / 1 1 / 2 1 12 / 0 9 / 2 1 03 / 3 0 / 2 2 RM B RM B LM W LM W 2345 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 1 \ 1 2 1 . 0 4 7 6 . 0 1 \ C A D D \ S P _ 1 2 1 0 4 7 6 _ L A N D . d w g LO R E N A W A S I O N , PL A N T I N G P L A N , 20 2 2 / 0 3 / 3 0 , 1: 5 8 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 50 PLANTING PLAN CONSTRUCTION NOTES 1.UTILITY WARNING: THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR RECORDS OBTAINED. THE SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEY FURTHER DOES NOT WARRANT THAT THE UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED. 2.NOTIFY UTILITY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXISTENCE, EXACT LOCATION AND DEPTH OF ALL UTILITIES. AVOID DAMAGE TO UTILITIES AND SERVICES DURING CONSTRUCTION. ANY DAMAGE DUE TO THE CONTRACTOR'S CARELESSNESS SHALL BE CORRECTED AT THE CONTRACTOR'S EXPENSE. COORDINATE AND COOPERATE WITH UTILITY COMPANIES DURING CONSTRUCTION. 3.ALL PLANT MATERIAL SHALL AT LEAST MEET MINIMUM REQUIREMENTS SHOWN IN THE "AMERICAN STANDARDS FOR NURSERY STOCK" (ANSI Z60.1-LATEST EDITION). 4.CONTRACTOR SHALL GUARANTEE ALL PLANT MATERIAL FOR A PERIOD OF ONE YEAR FROM DATE OF PROJECT ACCEPTANCE. 5.PROVIDE 3-INCH DEPTH SHREDDED HARDWOOD MULCH ON ALL TREE PLANTINGS IN LAWN AREAS AND LAWN AREA PLANTING BEDS UNLESS OTHERWISE DIRECTED BY OWNER. 6.ALL PLANTING BEDS TO RECEIVE 4 INCH DEPTH VERTICAL CUT EDGE, UNLESS OTHERWISE DIRECTED BY OWNER. 7.SOD ALL AREAS DISTURBED BY CONSTRUCTION WITHIN THE PROPOSED LOT AND THE ADJACENT RIGHT-OF-WAY. DISTURBED AREA ON LOT 2 TO BE SEEDED WITH TYPE 1 PERMANENT LAWN SEED MIX. 8.ALL SUBSTITUTIONS SHALL BE APPROVED IN WRITING BY THE CITY OF WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT. 9.OVERSTORY TREES SHALL BE A MINIMUM OF 8 FEET IN HEIGHT, EVERGREEN TREES SHALL BE MINIMUM OF 6 FEET IN HEIGHT, AND ORNAMENTAL TREES SHALL BE A MINIMUM OF 6 FEET IN HEIGHT. 1 C600 DECIDUOUS TREES STAKING DETAIL NO SCALE SEE PLANTING PIT DETAILS GARDEN HOSE FLAGGING MATERIAL 1 STAKING PLAN (TREES 2 1/2" DIA OR SMALLER) STAKING PLAN (TREES LARGER THAN 2 1/2" DIA) 1 WRAP TRUNK FROM GROUND TO FIRST BRANCH. 1 2 T O 2 3 T R E E H E I G H T (4 ' - 0 " M I N ) 1 4 TO 1 3 TREE HEIGHT (2'-0" MIN) 6" PLACE ON STAKE TO SOUTHWEST PLACE ON STAKE TO SOUTHWEST 2 C600 PLANTING PIT DETAILS NO SCALE TYPICAL PLANTING PIT DETAIL SLOPE PLANTING PIT DETAIL SET ROOT COLLAR AND ROOT FLARE 2" ABOVE FINISH GRADE. DO NOT PLACE MULCH WITHIN 2" OF TRUNK. ROOT COLLAR IS NOT ALWAYS LOCATED AT TOP OF ROOTBALL MINIMUM 6' DIAMETER, 3" DEPTH MULCH RING 3" HEIGHT WATER RETENTION BERM BEYOND EDGE OF ROOT BALL FINISH GRADE SCARIFY SIDES OF PIT REMOVE ALL NON-BIODEGRADABLE MATERIAL, CONTAINERS OR OTHER MATERIAL THAT WILL IMPEDE THE GROWTH OF THE PLANT MATERIAL. REMOVE ALL TWINE. FOR BALLED AND BURLAP (B&B) PLANTS REMOVE MINIMUM TOP 1 2 OF BURLAP AND WIRE BASKET MINIMUM. PLACE ROOT BALL ON UNDISTURBED SOIL 3X ROOTBALL MINIMUM FOR TREES 2X ROOTBAL MINIMUM FOR SHRUBS DE P T H O F RO O T B A L L OR C O N T A I N E R RO O T S Y S T E M 3X ROOTBALL MINIMUM FOR TREES 2X ROOTBAL MINIMUM FOR SHRUBS DE P T H O F RO O T B A L L OR C O N T A I N E R RO O T S Y S T E M 2:1 MAXIMUM TRANSITION SLOPE. BEGIN TRANSITION AT EDGE OF ROOT BALL EXISTING SLOPE TREE OR SHRUB SCARIFY SIDES OF PIT REMOVE ALL NON-BIODEGRADABLE MATERIAL, CONTAINERS OR OTHER MATERIAL THAT WILL IMPEDE THE GROWTH OF THE PLANT MATERIAL. REMOVE ALL TWINE. FOR BALLED AND BURLAP (B&B) PLANTS REMOVE MINIMUM TOP 1 2 OF BURLAP AND WIRE BASKET MINIMUM. PLACE ROOT BALL ON UNDISTURBED SOIL FINISH GRADE 3" HEIGHT WATER RETENTION BERM BEYOND EDGE OF ROOT BALL MINIMUM 6' DIAMETER, 3" DEPTH MULCH RING SET ROOT COLLAR AND ROOT FLARE 2" ABOVE FINISH GRADE. DO NOT PLACE MULCH WITHIN 2" OF TRUNK. ROOT COLLAR IS NOT ALWAYS LOCATED AT TOP OF ROOT BALL FINISH GRADE SEE PLANTING PIT DETAIL ENGINEERING FABRIC IMPERVIOUS SOIL SEPTIC GRAVEL 1 PERVIOUS SOIL (IF PRESENT) 1 IF PERVIOUS SOIL IS ENCOUNTERED AT A DEPTH LESS THAN 6-FEET, THE DRAINAGE WELL MAY BE TERMINATED WHERE THE WELL EXTENDS A MINIMUM OF 12-INCHES INTO THE PERVIOUS SOIL LAYER. 3 C600 TREE DRAINAGE WELL DETAIL NO SCALE NOTE: TREE DRAINAGE WELL ONLY REQUIRED IF IMPERVIOUS SOILS ARE FOUND DURING INSTALLATION AS PER SPECIFICATIONS AND AS APPROVED BY ENGINEER. ORNAMENTAL TREES 21 AG Amelanchier x grandiflora 'Autumn Brilliance'AUTUMN BRILLIANCE SERVICEBERRY 6' HT.B&B, MULTI-STEM 23 CR Crataegus crus-galli var. inermis THORNLESS COCKSPUR HAWTHORN 6' HT.B&B 41 MJ Malus 'Jarmin'MARILEE CRABAPPLE 6' HT.B&B 12 MP Malus x 'Prairifire'PRAIRIFIRE CRABAPPLE 6' HT.B&B 19 SR Syringa reticulata 'Ivory Silk'IVORY SILK JAPANESE TREE LILAC 6' HT.B&B SHRUBS 43 AB Aronia arbutifolia 'Brilliantissima'RED CHOCKBERRY 24" HT.CONT. (5' O.C) 94 CA Cornus alba 'Ivory Halo'IVORY HALO DOGWOOD 24" HT.CONT. (6' O.C) 23 CC Cotinus coggygria 'Ancot'GOLDEN SPIRIT SMOKEBUSH 36" HT.CONT. (8' O.C) 80 FO Forsythia x 'Show Off Sugar Baby'SHOW OFF SUGAR BABY FORSYTHIA 18" HT.CONT. (3' O.C) 56 HK Hypericum kalmianum 'Ames'AMES ST. JOHN'S WART 18" HT.CONT. (3' O.C) 68 HY Hydrangea paniculata 'Renhy'VANILLA STRAWBERRY HYDRANGEA 24" HT.CONT. (6' O.C) 91 PF Potentilla fruticosa 'Lundy'LUNDY SHRUBBY CINQUEFOIL 18" HT.CONT. (3' O.C) 63 PO Physocarpus opulifolius 'Jefam' Amber Jubilee AMBER JUBILEE NINEBARK 24" HT.CONT. (5' O.C) 19 SN Sambucus nigra 'Eva'BLACKLACE ELDERBERRY 36" HT.CONT. (8' O.C) 119 SB Spiraea betuliflora 'Tor'TOR BIRCHLEAF SPIREA 18" HT.CONT. (3' O.C) 41 VL Viburnum lantana 'Mohican'MOHICAN VIBURNUM 36" HT.CONT. (8' O.C) PLANTING PLAN REQUIREMENTS (LANDSCAPE CALCULATIONS BASED ON CITY OF WAUKEE ZONING CODE REQUIREMENTS, PER CHAPTER 161, AND THE SHOPS AT KETTLESTONE DESIGN GUIDELINES). MINIMUM OF 20% OPEN SPACE REQUIRED TOTAL AREA 344,053 SF MIN OPEN SPACE REQUIRED 68,810 SF (20.0%) OPEN SPACE PROVIDED 133,499 SF (38.8%) PLANTING REQUIREMENTS: ZONED R-4 = 2 TREES AND 2 SHRUBS PER DWELLING UNIT 29 TOTAL DWELLING UNITS X 2 = 58 TREES AND 58 SHRUBS REQUIRED ----TREES AND SHRUBS TO BE PROVIDED AT TIME OF HOME CONSTRUCTION. NON-BUFFER PLANTINGS: STREET TREE FRONTAGE REQUIREMENTS: 1 OVERSTORY TREE PER 40 LF OF FRONTAGE ALONG ESKER DRIVE 492 LF OF FRONTAGE = 492/40 = 12.30 OVERSTORY TREES REQUIRED (13 PROVIDED) BUFFER AND SCREENING REQUIREMENTS: BUFFER SCREEN PROVIDED FOR R-4 TO FUTURE R-1 ON EAST AND WEST BOUNDARIES. 25 FOOT BUFFER REQUIRES, PER 50 LINEAR FEET= 1.5 OVERSTORY TREE, 2.5 EVERGREEN TREES, 2.5 ORNAMENTAL TREES AND 15 SHRUBS. EAST BUFFER= 557 LF 557 / 50 = 11.14 PLANT UNITS ----11.14 P.U. x 1.5 OVERSTORY TREE = 17 OVERSTORY TREES REQUIRED, 17 OVERSTORY TREES PROVIDED ----11.14 P.U. x 2.5 EVERGREEN TREES = 28 EVERGREEN TREES REQUIRED, 28 EVERGREEN TREES PROVIDED ----11.14 P.U. x 2.5 ORNAMENTAL TREES = 28 ORNAMENTAL TREES REQUIRED, 28 ORNAMENTAL TREES PROVIDED ----11.14 P.U. x 15 SHRUBS = 167 SHRUBS REQUIRED, 167 SHRUBS PROVIDED WEST BUFFER= 737 LF 737 / 50 = 14.74 PLANT UNITS ----14.74 P.U. x 1.5 OVERSTORY TREE = 22 OVERSTORY TREES REQUIRED, 22 OVERSTORY TREES PROVIDED ----14.74 P.U. x 2.5 EVERGREEN TREES = 37 EVERGREEN TREES REQUIRED, 37 EVERGREEN TREES PROVIDED ----24 P.U. x 2.5 ORNAMENTAL TREES = 37 ORNAMENTAL TREES REQUIRED, 37 ORNAMENTAL TREES PROVIDED ----11.14 P.U. x 15 SHRUBS = 221 SHRUBS REQUIRED, 221 SHRUBS PROVIDED NORTH BUFFER= 522 LF 522 / 50 = 10.44 PLANT UNITS ----10.44 P.U. x 1.5 OVERSTORY TREE = 16 OVERSTORY TREES REQUIRED, 16 OVERSTORY TREES PROVIDED ----10.44 P.U. x 2.5 EVERGREEN TREES = 26 EVERGREEN TREES REQUIRED, 26 EVERGREEN TREES PROVIDED ----10.44 P.U. x 2.5 ORNAMENTAL TREES = 26 ORNAMENTAL TREES REQUIRED, 26 ORNAMENTAL TREES PROVIDED ----10.44 P.U. x 15 SHRUBS = 157 SHRUBS REQUIRED, 157 SHRUBS PROVIDED SOUTH BUFFER= 492 LF 492 / 50 = 9.84 PLANT UNITS ----9.84 P.U. x 1.5 OVERSTORY TREE = 15 OVERSTORY TREES REQUIRED, 15 OVERSTORY TREES PROVIDED ----9.84 P.U. x 2.5 EVERGREEN TREES = 25 EVERGREEN TREES REQUIRED, 25 EVERGREEN TREES PROVIDED ----9.84 P.U. x 2.5 ORNAMENTAL TREES = 25 ORNAMENTAL TREES REQUIRED, 25 ORNAMENTAL TREES PROVIDED ----9.84 P.U. x 15 SHRUBS = 148 SHRUBS REQUIRED, 148 SHRUBS PROVIDED PLANT SCHEDULE QTY KEY BOTANICAL NAME COMMON NAME INSTALL SIZE COMMENTS CANOPY TREES 6 AC Acer freemanii 'Jeffersred'AUTUMN BLAZE FREEMAN MAPLE 8' HT.B&B 7 CT Catalpa speciosa NORTHERN CATALPA 8' HT.B&B 8 CO Celtis occidentalis 'Prairie Pride'PRAIRIE PRIDE HACKBERRY 8' HT.B&B 6 GB Ginkgo biloba 'Autumn Gold'AUTUMN GOLD GINKGO 8' HT.B&B MALE ONLY 10 GL Gleditsia tricanthos var inermis 'Impcole'IMPERIAL HONEYLOCUST 8' HT.B&B 6 OV Ostrya virginiana IRONWOOD 8' HT.B&B 8 PS Robinia pseudoacacia 'Purple Robe'PURPLE ROBE 8' HT.B&B 6 QB Quercus bicolor SWAMP WHITE OAK 8' HT.B&B 7 QU Quercus warei 'Long'REGAL PRINCE OAK 8' HT.B&B, COLUMNAR 11 TA Tilia americana 'Boulevard'BOULEVARD AMERICAN LINDEN 8' HT.B&B 8 UP Ulmus 'Patriot'PATIRIOT ELM 8' HT.B&B EVERGREEN TREES 30 JS Juniperus scopulorum 'Bailigh'SKY HIGH JUNIPER 6' HT.B&B 18 JU Juniperus scopulorum 'Skyrocket'SKYROCKET JUNIPER 6' HT.B&B 8 PC Pinus cembra 'Swiss Stone'ALGONQUIN PILLAR SWISS STONE PINE 6' HT.B&B 11 PN Pinus flexilis 'Vanderwolf Pyramid'VANDERWOLF'S LIMBER PINE 6' HT.B&B 12 PI Picea glauca 'Densata'BLACK HILLS WHITE SPRUCE 6' HT.B&B 11 PG Picea pungens f. glauca 'Fat Albert'FAT ALBERT COLORADO SPRUCE 6' HT.B&B 15 PT Pinus mugo 'Tannenbaum'TANNENBAUM MUGO PINE 6' HT.B&B GENERAL NOTES B. Submit floor truss layouts showing beam locations, joist layout, locations of continuous duct chases, and maximum duct size in each chase. Allow designer five days for complete review. lumber package. Allow designer five days for complete review. manufacturer for review prior to ordering roof trusses and/or roof A. Submit roof truss and/or rafter layout plan as completed by the 12. SUBMITTALS 8. DOORS AND WINDOWS A. Exterior doors shall be selected by the Owner. B. House-to-garage doors shall be fire rated doors approved by governing codes. Face design to be selected by the Owner. C. Interior doors shall be selected by the Owner. D. Exterior windows by Pella Corp as selected by owner. E. Glazing in all doors and windows shall comply with governing codes. F. Install egress window units in accordance with governing codes. G. Door and window sizes indicated or drawings are as follows: "3/0x6/8" represents a door or window 3'-0" wide x 6'-8" high. Jamb depth to be coordinated by the Contractor. H. Finish hardware shall be selected by the owner. Install hardware in accordance with governing codes. 9. FINISHES A. Gypsum wallboard, unless noted otherwise, shall be provided as follows: 1. Exterior walls: One layer 1/2" regular wallboard to interior face. 2. Interior walls: One layer 1/2" regular wallboard each face. 3. Ceiling: One layer 5/8" regular wallboard. 4. Garage/House common wall: One layer 5/8" type "X" wallboard each face. 5. Baths: Water resistant wallboard at all walls and ceilings surrounding tubs and showers and as required by governing codes. Provide cement board as substrate for ceramic tile. B. Provide metal corner bead and trim at all locations recommended by the gypsum wallboard manufacturer. C. Tape, float, and sand joints and fasteners of gypsum wallboard with three coats of joint compound as required to obtain a uniformly smooth surface. D. Finishes shall be selected by the Owner. 10. PLUMBING, MECHANICAL, AND ELECTRICAL A. Plumbing, mechanical, and electrical information and layouts shown on the Drawings is schematic in design, and shall be reviewed by sub-contractors, suppliers, and building officials for compliance with governing codes and good common construction practices. The Architect shall be notified by the Contractor of any discrepancies prior to construction. B. Plumbing, mechanical, and electrical equipment shall be selected by the Owner. C. Design and installation of plumbing, mechanical, and electrical equipment shall be the responsibility of the appropriate licensed contractors and sub- contractors. Design shall be submitted for owner's review prior to ordering D. Service panels shall be selected by the electrical sub-contractor. E. All HVAC equipment shall be individually switched. F. All outdoor, bath, and garage and spa wall receptacles shall be provided with ground fault circuit protection in accordance with governing codes. G. Dryer vents shall be extended to the exterior. H. Provide plumbing vents in accordance with governing codes. Minimize number and locate for minimal visual impact. I. Install type and number of smoke detectors in accordance with governing codes & UL217. J. Connect water, gas, and electric services in accordance with governing codes. 11. MISCELLANEOUS and installation of equipment. exterior walls install plates over foam sill sealer. C. Unless noted otherwise, all slabs on grade shall be 4" thick, reinforced with 6x6 W1.4xW1.4 W.W.M., and placed over 4" minimum compacted sand or gravel fill. Interior slabs shall be placed over 6 mil. Stabilized polyethylene vapor barrier. Coordinate with radon removal procedures. D. Footing sizes shown are typical only for stated soil pressure and consistent compaction. Contractor shall be responsible for footings complying with A. Adhered masonry flashing must be installed at wall penetrations and terminations integrated with the WRB properly (when used), and installed in accordance with the to ensure a consistent overall project color on the wall. C. Install in accordance with manufacturer's installation instructions. Visit this page for http://ncmabr.org/pdfs/masterlibrary/MVMA%20Installation%20Guide%204th%20Edition%20web.pdf Consult manufacturer for proper installation instructions. modified mortar meeting ANSI A118.4 OR ANSI 118.15. F. Touch-up, repair or replace damaged stone before completion of project. A. All structural steel shall comply with appropriate ASTM Specifications as follows: ASTM A36, ASTM A53, ASTM A501, ASTM A307, and ASTM A. Lumber shall, in addition to complying with governing codes, comply with: 1. "Product Use Manual" of the Western Wood Products Association for selection and use of products included in that manual. 2. "Plywood Specification and Grade Guide" of the American Plywood 3. "Standard Specifications for Grades of California Redwood Lumber" of 4. American Wood Preservers Association standards and recommendations for fire-retardate and preservative pressure treated lumber and plywood. 5. Western Red Cedar Lumber Association standards and recommendations the Redwood Inspection Bureau for Redwood. for cedar. Association. D. Application details and mortar recommendations may vary depending on the stone style. E. All dry-stacked and large format standard stones must be applied using a polymer - 5. METALS A325. 6. WOOD AND PLASTICS the design requirements of specific soil conditions. of the stone veneer. Assure that all flashing and kickouts are corrosion resistant, local building code requirements. B. Product should be pulled from a variety of boxes and blended on site during intalllation installation instructions: 4. MASONRY Install skylights according to the manufactures' recommendations. I. Install water and ice barrier (Bituthene or equal) over roof sheathing at all eaves and valleys. water & ice barrier to extend 24" past outside face of L. Provide 2" nominal pressure treated lumber over foam sill sealer beneath full bearing of wood beams bearing on concrete or 7. THERMAL AND MOISTURE PROTECTION A. Provide thermal building insulation at assemblies adjacent to exterior or unheated spaces meeting the requirements of governing codes and, unless noted otherwise, meeting the following minimum requirements: 1. Foundations: 1 1/2"extruded polystyrene (R-10) 2. Walls: glass fiber batt (R-20) U.N.O. 3. Floors: glass fiber batt (R-30) -for floors over unconditioned space or exterior 4. Ceilings: glass fiber batt (R-49) 5. Install continuous blankets without holes for electrical boxes, lighting fixtures, or heating ductwork. B. Install 6 mil. stabilized polyethylene vapor barrier against interior face of all C. Waterproof foundation walls at excavated areas from footing to finished grade with two coats of asphalt based waterproofing compound for full basements. D. Roofing shall be 240 lb. (minimum) composition shingles installed over 15 lb. roof felt on roof sheathing. Minimum slope, fasteners, under layment, and exposure according to manufacturers' recommendations. E. Provide flashing and sheet metal required to prevent penetration of water through the exterior shell of the building. In addition to complying with governing codes, comply with pertinent recommendations contained in the current edition of "Architectural Sheet Metal Manual" published by SMCNA. All iron sheet metal flashing shall be hot-dipped galvanized complying with F. Provide gutters and downspouts to provide positive roof and site drainage. G. Provide attic and roof ventilation as required by governing codes and as shown on the Drawings. Provide appropriate soffit and roof vents. H. Skylights shall be selected by the Contractor and approved by the owner. ASTM A93. thermal insulation. masonry. 1. Before final Drawings and Specifications are issued for construction, they shall be submitted to all governing building agencies to insure their compliance with all applicable local and national codes. If code discrepancies in Drawings and/or Specifications appear, the Architect shall be notified of such discrepancies in writing by the Contractor or building official, and allowed to alter the drawings and specifications so as to comply with governing codes before construction begins. 2. Upon written receipt of approval from the governing official, approved final Drawings and Specifications shall be submitted to the Contractor by 3. If code discrepancies are discovered during the construction process, the Architect shall be notified and allowed ample time to remedy said 4. All work performed shall comply with all applicable local, state and national building codes, ordinances and regulations, and all other B. All contractors, suppliers, and fabricators shall be responsible for the content of the Drawings, and for the supply and design of appropriate C. All manufactured articles, materials, and equipment shall be handled, applied, installed, erected, used, cleaned, and conditioned in strict accordance with the D. All alternates are at the option of the Owner and shall be at the Owner's request, constructed in addition to or in lieu of the typical construction, as dead load 15psf (10 psf top, 5psf bottom) dead load 15psf (10 psf top, 5psf bottom) 5. Prior to start of construction, verify design loads with governing codes and site conditions. Check with local building agencies for wind, seismic, snow and other special loading conditions. If discrepancies are discovered, Architect shall be notified according to Section 1.A.1 above. A. Perform excavation, according to good common construction practices, to the lines, grades, and elevations indicated on the Drawings. B. Provide consistent compaction of the top 8" of sub-grade, fill, and backfill material beneath structures, walks, and pavements to meet the stated soil C. Provide soil poisoning to control termites as required by governing codes. D. Provide and install ventilation for Radon Gas as required by local building A. Provide concrete complying with ASTM C94. Unless otherwise noted, concrete shall have the following 28 day compressive strengths as minimums: 2. Concrete floor slabs, walks, drives, and patios: 3,500psi 3. Provide construction joints so panel size does not exceed 400sf. B. Provide reinforcement of the size and spacing indicated on Drawings. Reinforcing shall comply with the following minimums: live load 60psf (maximum) live load 40psf (maximum) live load 30psf (maximum) agencies and governing codes. 1. Concrete footings and foundations: 3,000psi 1. Bars: ASTM A615, grade 40, deformed bars. 2. Welded Wire Fabric: ASTM A185. 3. CONCRETE 2. SITE WORK pressure. materials and work performance. manufacturers' requirements. indicated on the Drawings. 3. Balconies and Decks: 4. Soil Pressure: 1500 psf (minimum) 2. Floor: 1. Roof: E. Design Loads: dead load 10psf 1. GENERAL REQUIREMENTS authorities having jurisdiction. discrepancies. the Architect. A. Codes: drawings to designer for review prior to construction. spacing of all trusses. Contractor to submit truss drawings and/or roof framing b. Install joist and beam hangers capable of supporting the maximum allowable load of joist or beam being supported. C. Provide "Micro-Lam" glue laminated veneer lumber beams (manufactured by Truss Joist Corporation) or equal, of the dimensions and number indicated on the drawings. Provide exterior grade Micro Lams for deck framing and other in strict accordance with manufacturers' recommendations. a. Modulus of elasticity: 2,000,000 psi b. Flexural (12" depth): 2,900 psi c. Horizontal shear: 285 psi D. Provide wood trusses able to sustain the stated loads for the spans, profiles, and arrangement shown on the Drawings. Truss layout is schematic only. Truss manufacturer and/or engineer shall be responsible for the design and E. All roof trusses shall be installed with metal truss seats as specified by the F. Unless noted otherwise, provide: 1. Double header joists and trimmers at all floor openings. 2. Double joists under all partitions parallel to joists. 3. Double 2x12 headers with 1/2 OSB between at all door and window openings in 2x4 walls. Triple 2x10 headers with 1/2" OSB between at all door and window openings at 2x6 walls. 4. For solid sawn joists, provide one row of 1x3 cross-bridging or metal bridging G. Stud spacing at all exterior and bearing walls shall be 16" o.c. minimum. H. Stud walls shall not exceed the following heights without continuous lateral support perpendicular to the plane of the wall at the stated height or less. Studs shall be continuous between points of lateral support. I. Unless noted otherwise, rafters, ceiling joists, collar ties, and purlins shall be sized and spaced in accordance with FHA requirements or governing codes, J. Stair construction shall consist of (3)2x12 stringers, 5/4" or 2x thick tread and 3/4" thick risers or, shall be fabricated by component manufacturer. K. All wood plates bearing on concrete or masonry shall be pressure treated. At b. 2x6: 12'-0' 2. Non-bearing walls: a. 2x4: 14'-0" b. 2x6: 20'-0" whichever is more restrictive. 1. Bearing walls: a. 2x4: 10'-0" for each 8'-0" of joist span. d. Bearing: 550 psi truss manufacturer. 1. Allowable stresses: B. Provide lumber and materials meeting or exceeding the following standards of a. Studs: Douglas Fir-Larch, Stud Grade -or as approved by building code. b. Headers and Beams: Douglas Fir-Larch, No. 2 and better -or as appoved by building code. 2. All headers and beams shall be free from splits, checks, and shakes. a. Roof: 1/2" OSB APA RATED SHEATHING, EXP 1. b. Walls: 1/2" OR 7/16" OSB APA RATED SHEATHING, EXP 1. c. Floor: 23/32" plywood APA RATED SHEATHING, EXP 1. d. Proper oriented strand board may be substituted for plywood. steel at exterior locations. a. Steel items: Comply with ASTM A36; use galvanized 3. Sheathing: (with clips) (glue and nail) 4. Rough Hardware: 1. Framing Members: quality: Contractor to submit steel shop drawings to designer or a licensed structural Construction and shall be detailed by a qualified structural steel detailer. B. All steel connections shall be designed according to AISC Manual of Steel engineer prior to steel erection. C. Architect will not be responsible for any errors in the roof and/or floor framing without the opportunity to review the roof and/or floor framing layouts. Framing layouts, member sizes, and floor/roof penetrations indicated on the drawings are for design intent only. Final layouts shall be the responsibility of builder. exterior applications. Unless noted otherwise, fasten multiple beams together exterior wall below. And as shown on the roof plan. A. This set of construction drawings is intended for design intent only. Although many jurisdictions will accept these drawings as sufficient for a construction permit, these drawings are not intended, and should not be construed, as a complete set of construction drawings. These drawings will have to be adapted to meet local zoning and/or site conditions and additional detailing will need to be completed on site by the builder. B. Install prefabricated fireplace units as shown on Drawings. 1. Fireplace units shall be "Heat-N-Glo" or as approved by Owner. 2. Contractor shall be responsible for proper installation as recommended by the manufacturer and as required by governing codes, including mantel and hearth design and location. C. Room sizes shown on the plans indicate room dimensions prior to installation of gypsum wall board. Gypsum wall board thickness must be subtracted from room sizes indicated for actual room dimensions and are subject to change. 2. Use exterior grade Micro-Lam in all areas subject to moisture. 3. Hearth shall be of non-combustible material. E. All excavations located beneath interior floor slabs (including garage) shall be inspected by a geotechnical engineer for bearing and the presence of unsuitable soils. If unsuitable soils are identified, the contractor shall follow the recommendations of the geotechnical engineer. F. All excavations located beneath footings and foundations shall be inspected by a geotechnical engineer for bearing and the presence of unsuitable soils. If unsuitable soils are identified, the contractor shall follow the recommendations of the geotechnical engineer. EARTH RIGID INSULATION CONCRETE BLOCK CONCRETE BRICK PLYWOOD STEEL OR STEEL STUD WALL BATT INSULATION GYPSUM BOARD GRAVEL WOOD OR WOOD STUD WALL SOUND INSULATION IN WALL MIN. (3) 2X SOLID BLOCKING BEARING WALL MATERIALS ELEVATION DRAWING NUMBER WALL TYPE SHEET NUMBER SHEET NUMBER SECTION DRAWING NUMBER DETAIL DRAWING NUMBER SHEET NUMBER POINT LOAD FROM ABOVE ELEVATION HEIGHT ELEVATION TYPE W2 SYMBOLS PELLA COOP PLAN INFORMATION PLAN OPTION: FOUNDATION: ROOF TRUSS: BORDEAUX ESTATE SLAB ON GRADE UPPER FLOOR BONUS ROOM FULL BASEMENT STANDARD ROOF TRUSSES 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : IS S U E D F O R : 11 - 2 3 - 2 0 FO R C O N S T R U C T I O N 11 - 3 0 - 2 0 RE V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 RE V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 OW N E R R E Q U E S T E D C H A N G E S A0 19-137.2 3-18-2021 MS P L A N LR KC VI N T A G E E S T A T E S - N O R T H L I B E R T Y BO R D E A U X E S T A T E V 1 TI T L E S H E E T SHEET LIST Sheet Number Sheet Name A0 TITLE SHEET A100 FOUNDATION PLAN A101 MAIN FLOOR PLAN A200 ELEVATIONS A201 DETAILS AREA SCHEDULE Level Name Area MAIN FLOOR MAIN FLOOR 1585 SF MAIN FLOOR GARAGE 557 SF Grand total: 2 2142 SF NOTE: THIS DRAWING IS AN ARTISTIC INTERPRETATION OF THE GENERAL APPEARANCE OF THE DESIGN. IT IS NOT INTENDED TO BE AN EXACT RENDITION. MAIN FLOOR 0" T.O.F. -6" B.O.F. -4' -0" W3W2 ***VERIFY ALL CHANGES IN WALL ELEVATION ON SITE. MAINTAIN 42" MINIMUM FROST PROTECTION AT ALL TIMES ***ALL FOUNDATION STEP- DOWNS TO BE DETERMINED ON SITE AS GRADE ALLOWS DROP T.O.F. @ O.H.D., VERIFY W/ GRADE 4' - 0 " 8" 6" 6" 3' - 0 " 8" 8"8" MA I N T A I N 4 2 " M I N . F R O S T 1' - 4"1' - 4" W1 6" 1' - 4" 3' - 6 " 8" CF 16 10 " 1' - 4" 4"4" W4 PR O T E C T I O N A T A L L T I M E S 8" 6" 3' - 6 " 8" 2' - 10"16' - 4"1' - 6"20' - 4" NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL NOTE: STEP FOOTINGS DOWN AS GRADE REQUIRES. MAINTAIN MINIMUM FROST PROTECTION AT ALL TIMES. NOTE: STEP FOUNDATION DOWN AS GRADE REQUIRES. MAINTAIN 42" MINIMUM FROST PROTECTION ON ALL FOOTINGS NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIALSTOOP ABOVE NOTE: CHANGES IN FOOTING AND FOUNDATION WALL ELEVATIONS ARE FOR DESIGN INTENT ONLY. ACTUAL ELEVATIONS SHALL BE VERIFIED W/FINAL GRADE DURING CONSTRUCTION. MAINTAIN 42" MINIMUM FROST PROTECTION ON ALL FOOTINGS. STEP DOWN FOOTING @ O.H.D. STOOP ABOVE 41' - 0" W2 W1 W1 W1 W1 W1 W1 W1 W1 W1 3' - 0 " 25 ' - 4 " 29 ' - 0 " 5' - 8 " 63 ' - 0 " 9' - 0"13' - 0"19' - 0" 41' - 0" NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL W4 W4 W4 W4 W1 W2 W2 W3 W1 W1 8" 39' - 8" 8" 8"20' - 8" 8" 5' - 8"12' - 8"8" 8' - 0 " 2' - 0 " 44 ' - 6 " 8' - 6 " 63 ' - 0 " 8" 2' - 10"16' - 4"2' - 10" W1 W1 DOWEL STOOP SLAB TO FOUNDATION TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL -VERIFY ALL CHANGES IN WALL ELEVATION ON SITE -MAINTAIN 42" MINIMUM FROST PROTECTION AT ALL TIMES POST P20 FOOTING F30 F24 CF16 1'-8'' 2'-6'' 2'-0'' 1'-4'' DIA 2'-6'' 2'-0'' CONT 4'-0'' 1'-0'' 1'-0'' 10'' (2) #4 CONT. #4 AT 12" O.C. E.W. #4 AT 12" O.C. E.W. (2) #4 CONT. -NOT ALL TYPES ARE USED F36 3'-0'' 3'-0'' 1'-0'' #4 AT 12" O.C. E.W. 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A100 19-137.2 3-18-2021 MS P L A N ML K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y BO R D E A U X E S T A T E V 1 FO U N D A T I O N P L A N SCALE: 1/4" = 1'-0"2 FOOTING LEGEND SCALE: 1/4" = 1'-0"1 FOUNDATION PLAN FOUNDATION SCHEDULE Type Mark WALL FOOTING Width Unconnected Height Hotizontal Reinforcements Vertical Reinforcements Footing Width Footing Length Footing Depth Footing Reinforcing W1 8" 3' - 6" #4 @ TOP & BOT. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. W2 8" 4' - 0" #4 @ TOP & BOT. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. W3 8" 3' - 0" #4 @ TOP & BOT. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. W4 8" 3' - 6" #4 @ TOP & BOT. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. 2 A201 4 A201 22' - 0"5' - 0"14' - 0" 34 ' - 4 " 5' - 4 1 / 2 " 4' - 3 " 11 ' - 0 1 / 2 " 3' - 0"16' - 0"3' - 0"2' - 6"2' - 6"7' - 3 1/8"6' - 8 7/8" W W.C. COVERED PORCH R/S R/ S R/S MUD/LAUN. MASTER BEDROOM BATH GUEST BEDROOM TWO CAR GARAGE 41' - 0" M. BATH M. CLOSET LOCKERS W.C. 3/0 x 6/8 PCKT 2/ 8 x 6 / 8 2/ 8 x 6 / 8 2/8 x 6/8 3/ 0 x 6 / 8 2/10 X 6/8 2/ 1 0 X 6 / 8 3/ 0 X 6 / 8 9' - 0"13' - 0"19' - 0" 41' - 0" 3' - 0 " 25 ' - 4 " 5' - 8 1 / 2 " 2' - 1 " 8' - 8 " 6' - 0 1 / 2 " 6' - 6 " 5' - 8 " 63 ' - 0 " PANTRY 3/0 x 6/8 DBL FOYER GUEST CLOSET COVERED PORCH PLUMBING WALL AS REQ'D FOR W/D HOOKUPS 29 3 5 C S M T 29 5 9 C S M T 2959 CSMT 2959 CSMT 1' - 1 0 " 4' - 8 " 2' - 1 0 " 2' - 1 0 " 6" 3' - 3"3' - 3"5' - 3 1/2"9' - 6"18' - 8 1/2"6" O.H.C. O. H . C . R/S 2' - 3"8' - 6"2' - 3" 6' - 1 1 / 4 " 5' - 8 " 2' - 1 0 " RO O F T R U S S A B V . @ 2 4 " O . C . EX. GRADE LVL BM ABOVE EX . G R A D E L V L B M A B O V E 2' - 10 1/2"8' - 1 1/2"8' - 0" 32 X 6 0 TU B / S H W R (2) 1 3/4" X 11 7/8" LVL HEADER ATTIC ACCESS ABOVE ROOF TRUSS ABV. @ 24" O.C. ROOF TRUSS ABV. @ 24" O.C. EX. GRADE LVL BM ABOVE 11 7 / 8 " F L O O R J O I S T S SP A C E P E R M F G R 2/ 1 0 X 6 / 8 RO O F T R U S S A B V . @ 2 4 " O . C . TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL NOTE: WALLS AND CEILING TO BE FINISHED W/ 5/8" TYPE "X" FIRE CODE GYPSUM BOARD RO O F T R U S S A B V . @ 2 4 " O . C . MECH. 3/0 x 6/8 FLOOR DRAIN 2' - 0"14' - 5 1/2"2' - 0" 2' - 0 " 2' - 0 " 2959 CSMT3- DW RANGE SINK RE F DINING LIVING ROOM KITCHEN P101 2 P101 1 3' - 3"5' - 5 1/2"12' - 3 1/2" 6' - 6"2' - 5"12' - 7"6" 6"12' - 9 1/2"8' - 4 1/2" 5' - 3"2' - 6 1/2"3' - 10 1/2"6' - 10 1/2"6" 2' - 0 " 3' - 7 " 7' - 3 " 2' - 0 " 6" 2' - 0 " 6" 8' - 6 1 / 2 " 4' - 3 " 2' - 4 1 / 2 " 3' - 0 " 25 ' - 4 " 6" 12 ' - 6 1 / 2 " 5' - 3 1 / 2 " 8' - 6 1 / 2 " 7' - 4 " 6" 24 ' - 9 1 / 2 " 6" 25 ' - 1 0 " 8' - 6 " 12" TRAY CLG. 12" TRAY CLG. OPTIONAL 12" TRAY NICHE HB FURNWH HB OPTIONAL POCKET DOOR OPTIONAL POCKET DOOR 3 A201 Sim 55 ' - 0 " R/ S 2/ 0 x 6 / 8 1/4 X 6/8 29 5 9 C S M T 2' - 6 " 3' - 6 " O.H.C. 29 2 9 T R S M A101 3 8 1 / 2 " 5' - 4 " SL O P E S L A B 6 " T O OV E R H E A D D O O R 0'-0" -0'-2" 2- 2' - 0 " 2' - 0" 2' - 0 " 2' - 0" 2' - 0 " 2' - 0" 3/0 x 6/8 3/ 0 X 6 / 8 2959 CSMT 5359 FXD 2959 CSMT CL LIN. CLO. 29 2 9 T R S M FULL HT. WALL 12 ' - 5 3 / 4 " 7' - 3 " 29 5 9 C S M T 2- A101 4 A201 7 5 18' - 6" A201 11 6 A201 10 (2) 1 3/4x11 7/8 LVL HDR (2) 1 3/4x11 7/8 LVL HDR LAV. LAV.LAV. MW HOOD D RI D G E ROOF NOTES: 2'-0" EAVE OVERHANG*** 1' - 6" GABLE RAKES*** 9:12 SLOPE SIDE TO SIDE*** 5:12 SLOPE FRONT TO BACK*** ***UNLESS NOTED OTHERWISE PROVIDE RIDGE, HIP AND SOFFIT VENTING TO COMPLY W/ GOVERNING CODES RI D G E OVERFRAMING AS REQ'D (TYPICAL SEE ELEVATIONS) SNOW AND ICE BARRIER ALONG ALL EAVES & RAKES 2' - 0" PAST OUTSIDE FACE OF FRAMING (TYPICAL @ ALL EXTERIOR EAVES) OUTSIDE FACE OF FRAMING BELOW RI D G E 5" / 1 2 " 5" / 1 2 " 6" / 12"6" / 12" 8" / 12"8" / 12" 8" / 12"8" / 12" O.H.C. O. H . C . DW RANGE SINK RE F O.H.C. A201 7 5 6 A201 8 9 2' - 3" 1/2" 3' - 0"3' - 3" 1 1/4" 2' - 6" 1 1/4" 3' - 3" 14' - 6" 1" 3' - 0 " 1" 2' - 6 " 2' - 6 " 3' - 0 " 1/ 2 " 2' - 3 " 13 ' - 5 1 / 2 " 1 1/2" 1' - 6"1' - 3"3' - 0"2' - 0"1" 1 1/2" 3/ 4 " 2' - 0 " 1' - 3 1 / 4 " 8' - 1" 3' - 4 " MW HOOD O. H . C . O . H . C . O . H . C .O.H.C.O.H.C. LAZY SUSAN W/ DOOR ATTACHED OP T . FP LIVING ROOM 29 2 9 T R S M 29 2 9 T R S M 2' - 7 " 2' - 2 " 5' - 0 " 2' - 2 " 2' - 0" 12" TRAY CLG. DW RANGE SINK RE F PANTRY KITCHEN MW HOOD 3' - 3" 1 1/4" 2' - 6" 1 1/4" 3' - 3" 9' - 2 1/2" 1" 3' - 0 " 1" 2' - 6 " 2' - 6 " 8' - 2 " 1 1/2" 1' - 6"1' - 3"3' - 0"2' - 0"1" 1 1/2"8' - 1" 3/ 4 " 2' - 0 " 1' - 3 1 / 4 " 3' - 4 " 1' - 6"1' - 6" 3' - 0" 1' - 1 0 1 / 2 " 1/2"5' - 0"1/2" 1' - 1 0 1 / 2 " 1' - 1 0 1 / 2 " 5' - 1" 1' - 0 1/4"2' - 11 1/2"1' - 0 1/4" 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A101 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y BO R D E A U X E S T A T E V 1 MA I N F L O O R P L A N SCALE: 1/4" = 1'-0"1 MAIN FLOOR- 1500 FLOOR PLAN SCALE: 1/4" = 1'-0"2 ROOF PLAN SCALE: 1/4" = 1'-0"3 KITCHEN - OPTION B SCALE: 1/4" = 1'-0"4 FIREPLACE OPTION SCALE: 1/4" = 1'-0"5 BORDEAUX KITCHEN SCALE: 1/4" = 1'-0"6 BORDEAUX BATH SCALE: 1/4" = 1'-0"7 BORDEAUX MASTER BATH O. H . C . O . H . C . O . H . C . O.H.C. O.H.C. MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MAIN WIN. H.H. 6' -10" UPPER LEVEL PLT HT 18' -2 7/8" T5 CONCRETE SLOPE TO GRADE UPPER FLOOR 10' -1 3/4" L1 8' - 1 1 / 8 " 1' - 0 5 / 8 " 9' - 1 1 / 8 " UPPER WIN. H.H. 16' -9 3/4" T1 M2 M1 T2 S2 3353 CSMT 2935 CSMT 2929 FXD T7 T4 F1 B1 T4 S4 S4 R1 1' - 6 " 4' - 0 " T7 B1 F1 T1 T7 T2 T1 S2 C1 M2 M1 T5 S1 T1 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE T5 T2 F1 T1 C1 F1 T2 M1 M2 S1 T5 T2 T1 S4 T1 R1 F1 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE M1 M2 MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MAIN WIN. H.H. 6' -10" T.O.F. -6"T1 S1 R1 F1 C1 S2 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE FIREPLACE OPTION B TRANSOM WINDOWS 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A200 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y BO R D E A U X E S T A T E V 1 EL E V A T I O N S SCALE: 1/4" = 1'-0"1 FRONT SCALE: 1/4" = 1'-0"2 BACK SCALE: 1/8" = 1'-0"3 LEFT SCALE: 1/8" = 1'-0"4 RIGHT Keynote Legend Key Value Keynote Text B1 DECORATIVE BRACKET - FYPON CRAFTSMAN BRACKET BKT04X12X16RI C1 COLUMN WRAP - OR - TRIM OUT COLUMN F1 6" ALUMINUM FASCIA OR 6" ALUMINUM RAKE L1 EXTERIOR WALL LIGHT M1 MASONRY- CULTURED STONE M2 MASONRY- STONE CAP R1 LAMINATED ASPHALT ROOF SHINGLES S1 (LAP SIDING) HARDIE-PLANK SIDING-7" MAX EXPOSURE S2 (STUCCO PANEL) HARDIE PANEL S3 (BOARD AND BATTEN SIDING) VERTICAL SIDING AND HARDIE TRIM S4 (SHAKE SIDING) T1 PAINTED HARDIE CORNER TRIM T2 4" PAINTED TRIM T4 6" OVER 8" PAINTED TRIM T5 7" OVER 12" PAINTED TRIM T7 4" TRIM AT WINDOWS ON FRONT ELEVATION ONLY 1X3 BATTENS ON SMOOTH PANEL SIDING SEE ROOF PLAN 36" PLASTIC ATTIC CHUTE SNOW AND ICE BARRIER EXTEND 24" PAST I.S. FACE OF EXTERIOR WALLS LAMINATED ASPHALT ROOF SHINGLES ON 15# ROOF FELT ON 1/2" O.S.B. SHEATHING MTL. DRIP 2X6 SUB-FASCIA VENTED ALUMINUM SOFFIT AND FASCIA ON 2X4 LOOKOUTS @ 24" O.C. 7" OVER 12" PAINTED TRIM SEE ELEVATIONS FOR SIDING MATERIAL WEATHER RESISTANT BARRIER OVER 1/2" O.S.B. SHEATHING ON 2X6 WALL STUDS @16" O.C. R21 INSULATION 1/2" GYP. BD. ON 6MIL POLY VAPOR BARRIER FLASHING (ALL HORIZ. JOINTS) 2X6 SILL PLATE "TRTD" ON CLOSED CELL FOAM SILL SEALER R49 BLOWN INSULATION 12 SE E R O O F PL A N MAIN FLOOR 12 " E N E R G Y H E E L M I N . T.O.F. 0'-0" 0'-4" FOUNDATION WALL-REFER TO PLAN TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL MAIN FLOOR PLT. HT. 9'-1 1/8" HOLD ALL TRIM AND SIDING MIN. 6" ABOVE GRADE 9' - 1 1 / 8 " CONTINUOUS BEAD OF SEALANT 4"4" 4' - 0 " LINE OF GRADE (VARIES) 2" 4" 2' - 0" HOLD ALL TRIM AND SIDING MIN. 6" MIN. ABOVE GRADE MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" T.O.F. -6" B.O.F. -4' -0" 9' - 9 1 / 8 " 3' - 4 " 8" 8' - 1 1 / 4 " 2" 11 7 / 8 " 8' - 3 1 / 4 " 4" 2" 4" 4" 1' - 6 " 2 1/2" 2"2" 2 1/2" SIMPSON POST STANDOFF 6X6 TRTD TIMBER POST BLOCKING AS REQ'D PAINTED COLUMN TRIM STONE CAP MAIN FLOOR 0" T.O.F. -6"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE GARAGE SLAB (SLOPE TO OVERHEAD DOOR) 4" FLOOR SLAB MAIN FLOOR 0'-0" TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL CONTINUOUS BEAD OF SEALANT 4"4" 2" 2' - 0"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE SLAB (SLOPE AWAY FROM HOUSE) MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 3' - 3" 1 1/4" 2' - 6" 1 1/4" 3' - 3" 9' - 2 1/2" 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 7' - 6 " 3' - 3"2' - 8 1/2"3' - 3" 9' - 2 1/2" MW HOOD RANGE PANTRY MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" PANTRY REF 1"3' - 0"1"2' - 6"2' - 6" 1' - 6 " 6' - 0 " 7' - 6 " 2' - 6"2' - 6" 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 7' - 6 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 1' - 6"1' - 3"3' - 0"2' - 0"1" 7' - 10" 2' - 1 0 1 / 2 " 1 1 / 2 " 3' - 0 " DW MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 3' - 0"3' - 3" 1 1/4" 2' - 6" 1 1/4" 3' - 3" 12' - 2 1/2" 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 7' - 6 " 2' - 6"3' - 3"2' - 8 1/2"3' - 3" 11' - 8 1/2" MW HOOD RANGE MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" REF 1' - 6 " 6' - 0 " 7' - 6 " 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 7' - 6 " 3' - 2"2' - 6"2' - 6"2' - 6" 7' - 6" 1"3' - 0"1"2' - 6"2' - 6"3' - 0" 11' - 2" MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 1/2"5' - 0"1/2" 5' - 1" 1 1 / 2 " 2' - 1 0 1 / 2 " 3' - 0 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 1 1 / 2 " 2' - 1 0 1 / 2 " 3' - 0 " 3' - 0" 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A201 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y BO R D E A U X E S T A T E V 1 DE T A I L S ROOM FINISH SCHEDULE- OVERALL ROOM NO ROOM NAME AREA FLOOR BASE WALLS CEILING NOTESN E S W FINISH HEIGHT 1 GUEST BEDROOM 133 SF CARPET 2 BATH 53 SF LVT 3 MASTER BEDROOM 149 SF CARPET 4 MUD/LAUN. 87 SF LVP 5 TWO CAR GARAGE 522 SF CONCRETE 6 M. BATH 92 SF LVT 7 M. CLOSET 53 SF CARPET 10 PANTRY 21 SF LVP 11 GUEST CLOSET 26 SF CARPET 13 LOFT 369 SF 14 FOYER 120 SF LVP 16 MECH. 56 SF CONCRETE 17 DINING 201 SF LVP 18 LIVING ROOM 262 SF LVP 20 KITCHEN 174 SF LVP 21 CL 6 SF LVP 22 LIN. CLO. 5 SF LVT NOTE: AREA'S ARE PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL FLOOR AREA'S PRIOR TO BIDDING AND CONSTRUCTION NOTE: VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION SCALE: 1/2" = 1'-0"1 TYP. WALL SECTION DOOR SCHEDULE Type To Room: Name Door CommentsWidth Height 2/10 X 6/8 BATH 2' - 10" 6' - 8" 1/4 x 6/8 BATH 1' - 4" 6' - 8" 3/0 x 6/8 DINING 3' - 0" 6' - 8" 36" x 80" DINING 3' - 0" 6' - 8" 3/0 X 6/8 FOYER 3' - 0" 6' - 8" 2/10 X 6/8 FOYER 2' - 10" 6' - 8" 2/0 x 6/8 FOYER 2' - 0" 6' - 8" 2/10 X 6/8 GUEST BEDROOM 2' - 10" 6' - 8" 3/0 x 6/8 KITCHEN 3' - 0" 6' - 8" 2/8 x 6/8 M. BATH 2' - 8" 6' - 8" Interior - Double Sliding Glass Shower Door M. BATH 5' - 0" 6' - 0" 2/8 x 6/8 M. CLOSET 2' - 8" 6' - 8" 3/0 x 6/8 MUD/LAUN. 3' - 0" 6' - 8" 3/0 x 6/8 PCKT MUD/LAUN. 3' - 0" 6' - 8" 2/8 x 6/8 MUD/LAUN. 2' - 8" 6' - 8" 3/0 x 6/8 MUD/LAUN. 3' - 0" 6' - 8" 3/0 x 6/8 MUD/LAUN. 3' - 0" 6' - 8" 16'-0" x 8'-0" TWO CAR GARAGE 16' - 0" 8' - 0" 3/0 x 6/8 TWO CAR GARAGE 3' - 0" 6' - 8" NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL DOORS PRIOR TO BIDDING AND CONSTRUCTION NOTE: VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION WINDOW SCHEDULE Level From Room: Name Type Comments MAIN FLOOR 2929 TRSM MAIN FLOOR 2929 TRSM MAIN FLOOR 2959 CSMT E MAIN FLOOR 2959 CSMT E MAIN FLOOR DINING 2929 TRSM MAIN FLOOR DINING 5359 FXD MAIN FLOOR DINING 2959 CSMT E MAIN FLOOR DINING 2959 CSMT E MAIN FLOOR GUEST BEDROOM 2959 CSMT E MAIN FLOOR GUEST BEDROOM 2959 CSMT E MAIN FLOOR GUEST BEDROOM 2959 CSMT E MAIN FLOOR LIVING ROOM 2929 TRSM MAIN FLOOR M. BATH 2935 CSMT E3 MAIN FLOOR MASTER BEDROOM 2959 CSMT E MAIN FLOOR MASTER BEDROOM 2959 CSMT E MAIN FLOOR MASTER BEDROOM 2959 CSMT E MAIN FLOOR MASTER BEDROOM 2959 CSMT E MAIN FLOOR MUD/LAUN. 2929 TRSM MAIN FLOOR: 18 UPPER FLOOR 2929 TRSM Porch Gable UPPER FLOOR TWO CAR GARAGE 3353 CSMT E Garage Gable UPPER FLOOR TWO CAR GARAGE 2935 CSMT E3 Garage Gable UPPER FLOOR TWO CAR GARAGE 2935 CSMT E3 Garage Gable UPPER FLOOR: 4 Grand total: 22 NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL WINDOWS PRIOR TO BIDDING AND CONSTRUCTION NOTE: VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION NOTE: GLASS SHOWER DOORS NOT INCLUDED IN SCHEDULE SCALE: 1/2" = 1'-0"4 TYP. COLUMN SCALE: 1" = 1'-0"2 TYP. ZERO ENTRY - GARAGE SCALE: 1" = 1'-0"3 TYP. ZERO ENTRY DETAIL - STOOP SCALE: 1/4" = 1'-0"5 KITCHEN ELEVATION 1 SCALE: 1/4" = 1'-0"6 KITCHEN ELEVATION 2 SCALE: 1/4" = 1'-0"7 KITCHEN ISLAND ELEVATION SCALE: 1/4" = 1'-0"8 KITCHEN OPTION B - ELEVATION 1 SCALE: 1/4" = 1'-0"9 KITCHEN OPTION B - ELEVATION 2 SCALE: 1/4" = 1'-0"11 MASTER BATH ELEVATION SCALE: 1/4" = 1'-0"10 BATH ELEVATION SCALE: 1" = 1'-0"12 TERMITE GUARD GENERAL NOTES B. Submit floor truss layouts showing beam locations, joist layout, locations of continuous duct chases, and maximum duct size in each chase. Allow designer five days for complete review. lumber package. Allow designer five days for complete review. manufacturer for review prior to ordering roof trusses and/or roof A. Submit roof truss and/or rafter layout plan as completed by the 12. SUBMITTALS 8. DOORS AND WINDOWS A. Exterior doors shall be selected by the Owner. B. House-to-garage doors shall be fire rated doors approved by governing codes. Face design to be selected by the Owner. C. Interior doors shall be selected by the Owner. D. Exterior windows by Pella Corp as selected by owner. E. Glazing in all doors and windows shall comply with governing codes. F. Install egress window units in accordance with governing codes. G. Door and window sizes indicated or drawings are as follows: "3/0x6/8" represents a door or window 3'-0" wide x 6'-8" high. Jamb depth to be coordinated by the Contractor. H. Finish hardware shall be selected by the owner. Install hardware in accordance with governing codes. 9. FINISHES A. Gypsum wallboard, unless noted otherwise, shall be provided as follows: 1. Exterior walls: One layer 1/2" regular wallboard to interior face. 2. Interior walls: One layer 1/2" regular wallboard each face. 3. Ceiling: One layer 5/8" regular wallboard. 4. Garage/House common wall: One layer 5/8" type "X" wallboard each face. 5. Baths: Water resistant wallboard at all walls and ceilings surrounding tubs and showers and as required by governing codes. Provide cement board as substrate for ceramic tile. B. Provide metal corner bead and trim at all locations recommended by the gypsum wallboard manufacturer. C. Tape, float, and sand joints and fasteners of gypsum wallboard with three coats of joint compound as required to obtain a uniformly smooth surface. D. Finishes shall be selected by the Owner. 10. PLUMBING, MECHANICAL, AND ELECTRICAL A. Plumbing, mechanical, and electrical information and layouts shown on the Drawings is schematic in design, and shall be reviewed by sub-contractors, suppliers, and building officials for compliance with governing codes and good common construction practices. The Architect shall be notified by the Contractor of any discrepancies prior to construction. B. Plumbing, mechanical, and electrical equipment shall be selected by the Owner. C. Design and installation of plumbing, mechanical, and electrical equipment shall be the responsibility of the appropriate licensed contractors and sub- contractors. Design shall be submitted for owner's review prior to ordering D. Service panels shall be selected by the electrical sub-contractor. E. All HVAC equipment shall be individually switched. F. All outdoor, bath, and garage and spa wall receptacles shall be provided with ground fault circuit protection in accordance with governing codes. G. Dryer vents shall be extended to the exterior. H. Provide plumbing vents in accordance with governing codes. Minimize number and locate for minimal visual impact. I. Install type and number of smoke detectors in accordance with governing codes & UL217. J. Connect water, gas, and electric services in accordance with governing codes. 11. MISCELLANEOUS and installation of equipment. exterior walls install plates over foam sill sealer. C. Unless noted otherwise, all slabs on grade shall be 4" thick, reinforced with 6x6 W1.4xW1.4 W.W.M., and placed over 4" minimum compacted sand or gravel fill. Interior slabs shall be placed over 6 mil. Stabilized polyethylene vapor barrier. Coordinate with radon removal procedures. D. Footing sizes shown are typical only for stated soil pressure and consistent compaction. Contractor shall be responsible for footings complying with A. Adhered masonry flashing must be installed at wall penetrations and terminations integrated with the WRB properly (when used), and installed in accordance with the to ensure a consistent overall project color on the wall. C. Install in accordance with manufacturer's installation instructions. Visit this page for http://ncmabr.org/pdfs/masterlibrary/MVMA%20Installation%20Guide%204th%20Edition%20web.pdf Consult manufacturer for proper installation instructions. modified mortar meeting ANSI A118.4 OR ANSI 118.15. F. Touch-up, repair or replace damaged stone before completion of project. A. All structural steel shall comply with appropriate ASTM Specifications as follows: ASTM A36, ASTM A53, ASTM A501, ASTM A307, and ASTM A. Lumber shall, in addition to complying with governing codes, comply with: 1. "Product Use Manual" of the Western Wood Products Association for selection and use of products included in that manual. 2. "Plywood Specification and Grade Guide" of the American Plywood 3. "Standard Specifications for Grades of California Redwood Lumber" of 4. American Wood Preservers Association standards and recommendations for fire-retardate and preservative pressure treated lumber and plywood. 5. Western Red Cedar Lumber Association standards and recommendations the Redwood Inspection Bureau for Redwood. for cedar. Association. D. Application details and mortar recommendations may vary depending on the stone style. E. All dry-stacked and large format standard stones must be applied using a polymer - 5. METALS A325. 6. WOOD AND PLASTICS the design requirements of specific soil conditions. of the stone veneer. Assure that all flashing and kickouts are corrosion resistant, local building code requirements. B. Product should be pulled from a variety of boxes and blended on site during intalllation installation instructions: 4. MASONRY Install skylights according to the manufactures' recommendations. I. Install water and ice barrier (Bituthene or equal) over roof sheathing at all eaves and valleys. water & ice barrier to extend 24" past outside face of L. Provide 2" nominal pressure treated lumber over foam sill sealer beneath full bearing of wood beams bearing on concrete or 7. THERMAL AND MOISTURE PROTECTION A. Provide thermal building insulation at assemblies adjacent to exterior or unheated spaces meeting the requirements of governing codes and, unless noted otherwise, meeting the following minimum requirements: 1. Foundations: 1 1/2"extruded polystyrene (R-10) 2. Walls: glass fiber batt (R-20) U.N.O. 3. Floors: glass fiber batt (R-30) -for floors over unconditioned space or exterior 4. Ceilings: glass fiber batt (R-49) 5. Install continuous blankets without holes for electrical boxes, lighting fixtures, or heating ductwork. B. Install 6 mil. stabilized polyethylene vapor barrier against interior face of all C. Waterproof foundation walls at excavated areas from footing to finished grade with two coats of asphalt based waterproofing compound for full basements. D. Roofing shall be 240 lb. (minimum) composition shingles installed over 15 lb. roof felt on roof sheathing. Minimum slope, fasteners, under layment, and exposure according to manufacturers' recommendations. E. Provide flashing and sheet metal required to prevent penetration of water through the exterior shell of the building. In addition to complying with governing codes, comply with pertinent recommendations contained in the current edition of "Architectural Sheet Metal Manual" published by SMCNA. All iron sheet metal flashing shall be hot-dipped galvanized complying with F. Provide gutters and downspouts to provide positive roof and site drainage. G. Provide attic and roof ventilation as required by governing codes and as shown on the Drawings. Provide appropriate soffit and roof vents. H. Skylights shall be selected by the Contractor and approved by the owner. ASTM A93. thermal insulation. masonry. 1. Before final Drawings and Specifications are issued for construction, they shall be submitted to all governing building agencies to insure their compliance with all applicable local and national codes. If code discrepancies in Drawings and/or Specifications appear, the Architect shall be notified of such discrepancies in writing by the Contractor or building official, and allowed to alter the drawings and specifications so as to comply with governing codes before construction begins. 2. Upon written receipt of approval from the governing official, approved final Drawings and Specifications shall be submitted to the Contractor by 3. If code discrepancies are discovered during the construction process, the Architect shall be notified and allowed ample time to remedy said 4. All work performed shall comply with all applicable local, state and national building codes, ordinances and regulations, and all other B. All contractors, suppliers, and fabricators shall be responsible for the content of the Drawings, and for the supply and design of appropriate C. All manufactured articles, materials, and equipment shall be handled, applied, installed, erected, used, cleaned, and conditioned in strict accordance with the D. All alternates are at the option of the Owner and shall be at the Owner's request, constructed in addition to or in lieu of the typical construction, as dead load 15psf (10 psf top, 5psf bottom) dead load 15psf (10 psf top, 5psf bottom) 5. Prior to start of construction, verify design loads with governing codes and site conditions. Check with local building agencies for wind, seismic, snow and other special loading conditions. If discrepancies are discovered, Architect shall be notified according to Section 1.A.1 above. A. Perform excavation, according to good common construction practices, to the lines, grades, and elevations indicated on the Drawings. B. Provide consistent compaction of the top 8" of sub-grade, fill, and backfill material beneath structures, walks, and pavements to meet the stated soil C. Provide soil poisoning to control termites as required by governing codes. D. Provide and install ventilation for Radon Gas as required by local building A. Provide concrete complying with ASTM C94. Unless otherwise noted, concrete shall have the following 28 day compressive strengths as minimums: 2. Concrete floor slabs, walks, drives, and patios: 3,500psi 3. Provide construction joints so panel size does not exceed 400sf. B. Provide reinforcement of the size and spacing indicated on Drawings. Reinforcing shall comply with the following minimums: live load 60psf (maximum) live load 40psf (maximum) live load 30psf (maximum) agencies and governing codes. 1. Concrete footings and foundations: 3,000psi 1. Bars: ASTM A615, grade 40, deformed bars. 2. Welded Wire Fabric: ASTM A185. 3. CONCRETE 2. SITE WORK pressure. materials and work performance. manufacturers' requirements. indicated on the Drawings. 3. Balconies and Decks: 4. Soil Pressure: 1500 psf (minimum) 2. Floor: 1. Roof: E. Design Loads: dead load 10psf 1. GENERAL REQUIREMENTS authorities having jurisdiction. discrepancies. the Architect. A. Codes: drawings to designer for review prior to construction. spacing of all trusses. Contractor to submit truss drawings and/or roof framing b. Install joist and beam hangers capable of supporting the maximum allowable load of joist or beam being supported. C. Provide "Micro-Lam" glue laminated veneer lumber beams (manufactured by Truss Joist Corporation) or equal, of the dimensions and number indicated on the drawings. Provide exterior grade Micro Lams for deck framing and other in strict accordance with manufacturers' recommendations. a. Modulus of elasticity: 2,000,000 psi b. Flexural (12" depth): 2,900 psi c. Horizontal shear: 285 psi D. Provide wood trusses able to sustain the stated loads for the spans, profiles, and arrangement shown on the Drawings. Truss layout is schematic only. Truss manufacturer and/or engineer shall be responsible for the design and E. All roof trusses shall be installed with metal truss seats as specified by the F. Unless noted otherwise, provide: 1. Double header joists and trimmers at all floor openings. 2. Double joists under all partitions parallel to joists. 3. Double 2x12 headers with 1/2 OSB between at all door and window openings in 2x4 walls. Triple 2x10 headers with 1/2" OSB between at all door and window openings at 2x6 walls. 4. For solid sawn joists, provide one row of 1x3 cross-bridging or metal bridging G. Stud spacing at all exterior and bearing walls shall be 16" o.c. minimum. H. Stud walls shall not exceed the following heights without continuous lateral support perpendicular to the plane of the wall at the stated height or less. Studs shall be continuous between points of lateral support. I. Unless noted otherwise, rafters, ceiling joists, collar ties, and purlins shall be sized and spaced in accordance with FHA requirements or governing codes, J. Stair construction shall consist of (3)2x12 stringers, 5/4" or 2x thick tread and 3/4" thick risers or, shall be fabricated by component manufacturer. K. All wood plates bearing on concrete or masonry shall be pressure treated. At b. 2x6: 12'-0' 2. Non-bearing walls: a. 2x4: 14'-0" b. 2x6: 20'-0" whichever is more restrictive. 1. Bearing walls: a. 2x4: 10'-0" for each 8'-0" of joist span. d. Bearing: 550 psi truss manufacturer. 1. Allowable stresses: B. Provide lumber and materials meeting or exceeding the following standards of a. Studs: Douglas Fir-Larch, Stud Grade -or as approved by building code. b. Headers and Beams: Douglas Fir-Larch, No. 2 and better -or as appoved by building code. 2. All headers and beams shall be free from splits, checks, and shakes. a. Roof: 1/2" OSB APA RATED SHEATHING, EXP 1. b. Walls: 1/2" OR 7/16" OSB APA RATED SHEATHING, EXP 1. c. Floor: 23/32" plywood APA RATED SHEATHING, EXP 1. d. Proper oriented strand board may be substituted for plywood. steel at exterior locations. a. Steel items: Comply with ASTM A36; use galvanized 3. Sheathing: (with clips) (glue and nail) 4. Rough Hardware: 1. Framing Members: quality: Contractor to submit steel shop drawings to designer or a licensed structural Construction and shall be detailed by a qualified structural steel detailer. B. All steel connections shall be designed according to AISC Manual of Steel engineer prior to steel erection. C. Architect will not be responsible for any errors in the roof and/or floor framing without the opportunity to review the roof and/or floor framing layouts. Framing layouts, member sizes, and floor/roof penetrations indicated on the drawings are for design intent only. Final layouts shall be the responsibility of builder. exterior applications. Unless noted otherwise, fasten multiple beams together exterior wall below. And as shown on the roof plan. A. This set of construction drawings is intended for design intent only. Although many jurisdictions will accept these drawings as sufficient for a construction permit, these drawings are not intended, and should not be construed, as a complete set of construction drawings. These drawings will have to be adapted to meet local zoning and/or site conditions and additional detailing will need to be completed on site by the builder. B. Install prefabricated fireplace units as shown on Drawings. 1. Fireplace units shall be "Heat-N-Glo" or as approved by Owner. 2. Contractor shall be responsible for proper installation as recommended by the manufacturer and as required by governing codes, including mantel and hearth design and location. C. Room sizes shown on the plans indicate room dimensions prior to installation of gypsum wall board. Gypsum wall board thickness must be subtracted from room sizes indicated for actual room dimensions and are subject to change. 2. Use exterior grade Micro-Lam in all areas subject to moisture. 3. Hearth shall be of non-combustible material. E. All excavations located beneath interior floor slabs (including garage) shall be inspected by a geotechnical engineer for bearing and the presence of unsuitable soils. If unsuitable soils are identified, the contractor shall follow the recommendations of the geotechnical engineer. F. All excavations located beneath footings and foundations shall be inspected by a geotechnical engineer for bearing and the presence of unsuitable soils. If unsuitable soils are identified, the contractor shall follow the recommendations of the geotechnical engineer. EARTH RIGID INSULATION CONCRETE BLOCK CONCRETE BRICK PLYWOOD STEEL OR STEEL STUD WALL BATT INSULATION GYPSUM BOARD GRAVEL WOOD OR WOOD STUD WALL SOUND INSULATION IN WALL MIN. (3) 2X SOLID BLOCKING BEARING WALL MATERIALS ELEVATION DRAWING NUMBER WALL TYPE SHEET NUMBER SHEET NUMBER SECTION DRAWING NUMBER DETAIL DRAWING NUMBER SHEET NUMBER POINT LOAD FROM ABOVE ELEVATION HEIGHT ELEVATION TYPE W2 SYMBOLS PELLA COOP PLAN INFORMATION PLAN OPTION: FOUNDATION: ROOF TRUSS: BORDEAUX ESTATE SLAB ON GRADE UPPER FLOOR BONUS ROOM FULL BASEMENT STANDARD ROOF TRUSSES 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : IS S U E D F O R : 11 - 2 3 - 2 0 FO R C O N S T R U C T I O N 11 - 3 0 - 2 0 RE V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 RE V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 OW N E R R E Q U E S T E D C H A N G E S A0 19-137.2 3-18-2021 MS P L A N LR KC VI N T A G E E S T A T E S - N O R T H L I B E R T Y BO R D E A U X E S T A T E V 2 TI T L E S H E E T SHEET LIST Sheet Number Sheet Name A0 TITLE SHEET A100 FOUNDATION PLAN A101 MAIN FLOOR PLAN A200 ELEVATIONS A201 DETAILS AREA SCHEDULE Level Name Area MAIN FLOOR MAIN FLOOR 1620 SF MAIN FLOOR GARAGE 557 SF Grand total: 2 2177 SF NOTE: THIS DRAWING IS AN ARTISTIC INTERPRETATION OF THE GENERAL APPEARANCE OF THE DESIGN. IT IS NOT INTENDED TO BE AN EXACT RENDITION. MAIN FLOOR 0" T.O.F. -6" B.O.F. -4' -0" W3W2 ***VERIFY ALL CHANGES IN WALL ELEVATION ON SITE. MAINTAIN 42" MINIMUM FROST PROTECTION AT ALL TIMES ***ALL FOUNDATION STEP- DOWNS TO BE DETERMINED ON SITE AS GRADE ALLOWS DROP T.O.F. @ O.H.D., VERIFY W/ GRADE 4' - 0 " 8" 6" 6" 3' - 0 " 8" 8"8" MA I N T A I N 4 2 " M I N . F R O S T 1' - 4"1' - 4" W1 6" 1' - 4" 3' - 6 " 8" CF 16 10 " 1' - 4" 4"4" W4 PR O T E C T I O N A T A L L T I M E S 8" 6" 3' - 6 " 8" 2' - 10"16' - 4"1' - 6"20' - 4" NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL NOTE: STEP FOOTINGS DOWN AS GRADE REQUIRES. MAINTAIN MINIMUM FROST PROTECTION AT ALL TIMES. NOTE: STEP FOUNDATION DOWN AS GRADE REQUIRES. MAINTAIN 42" MINIMUM FROST PROTECTION ON ALL FOOTINGS NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIALSTOOP ABOVE NOTE: CHANGES IN FOOTING AND FOUNDATION WALL ELEVATIONS ARE FOR DESIGN INTENT ONLY. ACTUAL ELEVATIONS SHALL BE VERIFIED W/FINAL GRADE DURING CONSTRUCTION. MAINTAIN 42" MINIMUM FROST PROTECTION ON ALL FOOTINGS. STEP DOWN FOOTING @ O.H.D. STOOP ABOVE 41' - 0" W2 W1 W1 W1 W1 W1 W1 W1 W1 W1 3' - 0 " 25 ' - 4 " 29 ' - 0 " 5' - 8 " 63 ' - 0 " 9' - 0"17' - 0"15' - 0" 41' - 0" NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL W4 W4 W4 W4 W1 W2 W2 W3 W1 W1 8" 39' - 8" 8" 8"20' - 8" 8" 5' - 8"12' - 8"8" 8' - 0 " 2' - 0 " 44 ' - 6 " 8' - 6 " 63 ' - 0 " 8" 2' - 10"16' - 4"2' - 10" W1 W1 DOWEL STOOP SLAB TO FOUNDATION TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL -VERIFY ALL CHANGES IN WALL ELEVATION ON SITE -MAINTAIN 42" MINIMUM FROST PROTECTION AT ALL TIMES POST P20 FOOTING F30 F24 CF16 1'-8'' 2'-6'' 2'-0'' 1'-4'' DIA 2'-6'' 2'-0'' CONT 4'-0'' 1'-0'' 1'-0'' 10'' (2) #4 CONT. #4 AT 12" O.C. E.W. #4 AT 12" O.C. E.W. (2) #4 CONT. -NOT ALL TYPES ARE USED F36 3'-0'' 3'-0'' 1'-0'' #4 AT 12" O.C. E.W. 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A100 19-137.2 3-18-2021 MS P L A N ML K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y BO R D E A U X E S T A T E V 2 FO U N D A T I O N P L A N SCALE: 1/4" = 1'-0"2 FOOTING LEGEND SCALE: 1/4" = 1'-0"1 FOUNDATION PLAN FOUNDATION SCHEDULE Type Mark WALL FOOTING Width Unconnected Height Hotizontal Reinforcements Vertical Reinforcements Footing Width Footing Length Footing Depth Footing Reinforcing W1 8" 3' - 6" #4 @ TOP & BOT. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. W2 8" 4' - 0" #4 @ TOP & BOT. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. W3 8" 3' - 0" #4 @ TOP & BOT. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. W4 8" 3' - 6" #4 @ TOP & BOT. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. 2 A201 4 A201 22' - 0"5' - 0"14' - 0" 34 ' - 4 " 5' - 4 1 / 2 " 4' - 3 " 11 ' - 0 1 / 2 " 3' - 0"16' - 0"3' - 0"2' - 6"2' - 6"7' - 3 1/8"6' - 8 7/8" W W.C. COVERED PORCH R/S R/ S R/S MUD/LAUN. MASTER BEDROOM BATH GUEST BEDROOM TWO CAR GARAGE 41' - 0" M. BA M. CLOSET LOCKERS W.C. 3/0 x 6/8 PCKT 2/ 8 x 6 / 8 2/ 8 x 6 / 8 2/8 x 6/8 3/ 0 x 6 / 8 2/10 X 6/8 2/ 1 0 X 6 / 8 3/ 0 X 6 / 8 9' - 0"17' - 0"15' - 0" 41' - 0" 3' - 0 " 25 ' - 4 " 5' - 8 1 / 2 " 2' - 1 " 8' - 8 " 6' - 0 1 / 2 " 6' - 6 " 5' - 8 " 63 ' - 0 " PANTRY 3/0 x 6/8 DBL FOYER GUEST CLOSET COVERED PORCH PLUMBING WALL AS REQ'D FOR W/D HOOKUPS 29 3 5 C S M T 29 5 9 C S M T 2959 CSMT 2959 CSMT 1' - 1 0 " 4' - 8 " 2' - 1 0 " 2' - 1 0 " 6" 3' - 3"3' - 3"5' - 3 1/2"9' - 3 1/2"18' - 11"6" O.H.C. O. H . C . R/S 2' - 10"11' - 4"2' - 10" 6' - 1 1 / 4 " 5' - 8 " 2' - 1 0 " RO O F T R U S S A B V . @ 2 4 " O . C . EX. GRADE LVL BM ABOVE EX . G R A D E L V L B M A B O V E 2' - 8"6' - 8"5' - 8" 32 X 6 0 TU B / S H W R (2) 1 3/4" X 11 7/8" LVL HEADER ATTIC ACCESS ABOVE ROOF TRUSS ABV. @ 24" O.C. ROOF TRUSS ABV. @ 24" O.C. EX. GRADE LVL BM ABOVE 11 7 / 8 " F L O O R J O I S T S SP A C E P E R M F G R 2/ 1 0 X 6 / 8 RO O F T R U S S A B V . @ 2 4 " O . C . TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL NOTE: WALLS AND CEILING TO BE FINISHED W/ 5/8" TYPE "X" FIRE CODE GYPSUM BOARD RO O F T R U S S A B V . @ 2 4 " O . C . MECH. 3/0 x 6/8 FLOOR DRAIN 2' - 0"14' - 5 1/2"2' - 0" 2' - 0 " 2' - 0 " 2959 CSMT3- DW RANGE SINK RE F DINING LIVING ROOM KITCHEN 2959 CSMT 2959 CSMT 3/ 0 X 6 / 8 P101 2 P101 1 3' - 3"5' - 5 1/2"16' - 3 1/2" 6' - 6"2' - 5"12' - 7" 6" 6"12' - 9 1/2"8' - 4 1/2" 5' - 3"2' - 6 1/2"3' - 10 1/2"6' - 10 1/2"6" 2' - 0 " 10 ' - 6 " 3' - 7 " 7' - 2 1 / 2 " 2' - 0 " 6" 2' - 0 " 6" 8' - 6 1 / 2 " 4' - 3 " 2' - 4 1 / 2 " 3' - 0 " 25 ' - 4 " 6" 12 ' - 6 1 / 2 " 5' - 3 1 / 2 " 8' - 6 1 / 2 " 7' - 4 " 6" 24 ' - 9 1 / 2 " 6" 25 ' - 1 0 " 8' - 6 " 12" TRAY CLG. 12" TRAY CLG. OPTIONAL 12" TRAY NICHE HB FURNWH HB OPTIONAL POCKET DOOR OPTIONAL POCKET DOOR 3 A201 Sim 55 ' - 0 " R/ S 2/ 0 x 6 / 8 1/4 X 6/8 29 5 9 C S M T 2' - 6 " 3' - 6 " O.H.C. 29 2 9 T R S M A101 3 8 1 / 2 " 5' - 4 " SL O P E S L A B 6 " T O OV E R H E A D D O O R 0'-0" -0'-2" 2- 3/0 x 6/8 2' - 0 " 2' - 0" 2' - 0 " 2' - 0" 2' - 0 " 2' - 0" 2' - 0"1 3 5 .0 0 ° CL LIN. CLO. A101 4 29 5 9 C S M T 12 ' - 5 3 / 4 " 7' - 3 " 29 2 9 T R S M FULL HT. WALL (2) 1 3/4x11 7/8 LVL HDR (2) 1 3/4x11 7/8 LVL HDR LAV. LAV.LAV. A201 11 A201 10 A201 5 6 7 A201 MW HOOD D RI D G E ROOF NOTES: 2'-0" EAVE OVERHANG*** 1' - 6" GABLE RAKES*** 9:12 SLOPE SIDE TO SIDE*** 5:12 SLOPE FRONT TO BACK*** ***UNLESS NOTED OTHERWISE PROVIDE RIDGE, HIP AND SOFFIT VENTING TO COMPLY W/ GOVERNING CODES RI D G E OVERFRAMING AS REQ'D (TYPICAL SEE ELEVATIONS) SNOW AND ICE BARRIER ALONG ALL EAVES & RAKES 2' - 0" PAST OUTSIDE FACE OF FRAMING (TYPICAL @ ALL EXTERIOR EAVES) OUTSIDE FACE OF FRAMING BELOW RI D G E 5" / 1 2 " 5" / 1 2 " 6" / 12"6" / 12" 8" / 12"8" / 12" 8" / 12"8" / 12" O.H.C. O. H . C . DW RANGE SINK RE F O.H.C. 2' - 3" 1/2" 3' - 0"3' - 3" 1 1/4" 2' - 6" 1 1/4" 3' - 0" 14' - 2 7/8" A201 5 6 7 A201 8 9 1" 3' - 0 " 1" 2' - 6 " 2' - 6 " 3' - 0 " 1/ 2 " 2' - 3 " 13 ' - 5 1 / 2 " 1' - 0 " 1' - 1 " 2' - 1 " 1 1/2" 1' - 6"1' - 3"3' - 0"2' - 0"1" 1 1/2"8' - 1" 2' - 0 3 / 4 " 1' - 3 1 / 4 " 3' - 4 " MW HOOD O. H . C . O . H . C . O . H . C . O.H.C.O.H.C. LAZY SUSAN W/ DOOR ATTACHED OP T . FP LIVING ROOM 29 2 9 T R S M 29 2 9 T R S M 2' - 7 " 2' - 2 " 5' - 0 " 2' - 2 " 2' - 0" 12" TRAY CLG. PANTRY DW RANGE SINK RE F 3' - 3" 1 1/4" 2' - 6" 1 1/4" 3' - 0" 8' - 11 1/2" 1' - 0 " 1' - 1 " 1" 3' - 0 " 1"2' - 6 " 2' - 6 " 8' - 2 " 1 1/2" 1' - 6"1' - 3"3' - 0"2' - 0" 1" 1 1/2" 3/ 4 " 2' - 0 " 1' - 3 1 / 4 " 3' - 4 " 8' - 1" MW HOODO.H.C.O.H.C. O. H . C . O . H . C . O . H . C . 3' - 0" 1' - 1 0 1 / 2 " 1' - 6"1' - 6" 1/2"5' - 0"1/2" 5' - 1" 1' - 1 0 1 / 2 " 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A101 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y BO R D E A U X E S T A T E V 2 MA I N F L O O R P L A N SCALE: 1/4" = 1'-0"1 MAIN FLOOR- 1500 FLOOR PLAN SCALE: 1/4" = 1'-0"2 ROOF PLAN SCALE: 1/4" = 1'-0"3 KITCHEN - OPTION B SCALE: 1/4" = 1'-0"4 FIREPLACE OPTION SCALE: 1/4" = 1'-0"5 BORDEAUX KITCHEN SCALE: 1/4" = 1'-0"6 BORDEAUX BATH SCALE: 1/4" = 1'-0"7 BORDEAUX MASTER BATH MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MAIN WIN. H.H. 6' -10" UPPER LEVEL PLT HT 18' -2 7/8" T5 CONCRETE SLOPE TO GRADE UPPER FLOOR 10' -1 3/4" L1 8' - 1 1 / 8 " 1' - 0 5 / 8 " 9' - 1 1 / 8 " UPPER WIN. H.H. 16' -9 3/4" T1 M2 M1 T2 S2 3353 CSMT 2935 CSMT 2929 FXD T7 T4 F1 B1 T4 S4 S4 R1 1' - 6 " 4' - 0 " T7 B1 F1 T1 T7 T2 T1 S2 C1 M2 M1 T5 S1 T1 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE T5 T2 F1 T1 C1 F1 T2 M1 M2 S1 T5 T2 T1 S4 T1 R1 F1 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE M1 M2 MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MAIN WIN. H.H. 6' -10" T.O.F. -6"T1 S1 R1 F1 C1 S2 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE FIREPLACE OPTION B TRANSOM WINDOWS 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A200 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y BO R D E A U X E S T A T E V 2 EL E V A T I O N S SCALE: 1/4" = 1'-0"1 FRONT SCALE: 1/4" = 1'-0"2 BACK SCALE: 1/8" = 1'-0"3 LEFT SCALE: 1/8" = 1'-0"4 RIGHT Keynote Legend Key Value Keynote Text B1 DECORATIVE BRACKET - FYPON CRAFTSMAN BRACKET BKT04X12X16RI C1 COLUMN WRAP - OR - TRIM OUT COLUMN F1 6" ALUMINUM FASCIA OR 6" ALUMINUM RAKE L1 EXTERIOR WALL LIGHT M1 MASONRY- CULTURED STONE M2 MASONRY- STONE CAP R1 LAMINATED ASPHALT ROOF SHINGLES S1 (LAP SIDING) HARDIE-PLANK SIDING-7" MAX EXPOSURE S2 (STUCCO PANEL) HARDIE PANEL S3 (BOARD AND BATTEN SIDING) VERTICAL SIDING AND HARDIE TRIM S4 (SHAKE SIDING) T1 PAINTED HARDIE CORNER TRIM T2 4" PAINTED TRIM T4 6" OVER 8" PAINTED TRIM T5 7" OVER 12" PAINTED TRIM T7 4" TRIM AT WINDOWS ON FRONT ELEVATION ONLY 1X3 BATTENS ON SMOOTH PANEL SIDING SEE ROOF PLAN 36" PLASTIC ATTIC CHUTE SNOW AND ICE BARRIER EXTEND 24" PAST I.S. FACE OF EXTERIOR WALLS LAMINATED ASPHALT ROOF SHINGLES ON 15# ROOF FELT ON 1/2" O.S.B. SHEATHING MTL. DRIP 2X6 SUB-FASCIA VENTED ALUMINUM SOFFIT AND FASCIA ON 2X4 LOOKOUTS @ 24" O.C. 7" OVER 12" PAINTED TRIM SEE ELEVATIONS FOR SIDING MATERIAL WEATHER RESISTANT BARRIER OVER 1/2" O.S.B. SHEATHING ON 2X6 WALL STUDS @16" O.C. R21 INSULATION 1/2" GYP. BD. ON 6MIL POLY VAPOR BARRIER FLASHING (ALL HORIZ. JOINTS) 2X6 SILL PLATE "TRTD" ON CLOSED CELL FOAM SILL SEALER R49 BLOWN INSULATION 12 SE E R O O F PL A N MAIN FLOOR 12 " E N E R G Y H E E L M I N . T.O.F. 0'-0" 0'-4" FOUNDATION WALL-REFER TO PLAN TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL MAIN FLOOR PLT. HT. 9'-1 1/8" HOLD ALL TRIM AND SIDING MIN. 6" ABOVE GRADE 9' - 1 1 / 8 " CONTINUOUS BEAD OF SEALANT 4"4" 4' - 0 " LINE OF GRADE (VARIES) 2" 4" 2' - 0" HOLD ALL TRIM AND SIDING MIN. 6" MIN. ABOVE GRADE MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" T.O.F. -6" B.O.F. -4' -0" 9' - 9 1 / 8 " 3' - 4 " 8" 8' - 1 1 / 4 " 2" 11 7 / 8 " 8' - 3 1 / 4 " 4" 2" 4" 4" 1' - 6 " 2 1/2" 2"2" 2 1/2" SIMPSON POST STANDOFF 6X6 TRTD TIMBER POST BLOCKING AS REQ'D PAINTED COLUMN TRIM STONE CAP MAIN FLOOR 0" T.O.F. -6"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE GARAGE SLAB (SLOPE TO OVERHEAD DOOR) 4" FLOOR SLAB MAIN FLOOR 0'-0" TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL CONTINUOUS BEAD OF SEALANT 4"4" 2" 2' - 0"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE SLAB (SLOPE AWAY FROM HOUSE) MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MW HOOD RANGE 3' - 3" 1 1/4" 2' - 6" 1 1/4" 3' - 0" 8' - 11 1/2" 3' - 3"2' - 8 1/2"3' - 0" 8' - 11 1/2" 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 7' - 6 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" PANTRY REF 1"3' - 0"1"2' - 6"2' - 6" 8' - 2" 1' - 6 " 6' - 0 " 7' - 6 " 3' - 2"2' - 6"2' - 6" 8' - 2" 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 7' - 6 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" DW 1"2' - 0"3' - 0"1' - 3"1' - 6" 7' - 10" 2' - 1 0 1 / 2 " 1 1 / 2 " 3' - 0 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MW HOOD RANGE 3' - 0"3' - 3" 1 1/4" 2' - 6" 1 1/4" 3' - 0" 11' - 11 1/2" 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 7' - 6 " 2' - 6"3' - 3"2' - 8 1/2"3' - 0" 11' - 5 1/2" MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" REF 1"3' - 0" 1" 2' - 6"2' - 6"3' - 0" 11' - 2" 6' - 0 " 1' - 6 " 7' - 6 " 2' - 6"2' - 6"2' - 6" 7' - 6" 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 7' - 6 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 5' - 1"1/2" 5' - 0"1/2" 1 1 / 2 " 2' - 1 0 1 / 2 " 3' - 0 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 1 1 / 2 " 2' - 1 0 1 / 2 " 3' - 0 " 3' - 0" 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A201 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y BO R D E A U X E S T A T E V 2 DE T A I L S ROOM FINISH SCHEDULE- OVERALL ROOM NO ROOM NAME AREA FLOOR BASE WALLS CEILING NOTESN E S W FINISH HEIGHT 1 GUEST BEDROOM 133 SF CARPET 2 BATH 53 SF LVT 3 MASTER BEDROOM 193 SF CARPET 4 MUD/LAUN. 87 SF LVP 5 TWO CAR GARAGE 522 SF CONCRETE 6 M. BA 92 SF LVT 7 M. CLOSET 53 SF CARPET 10 PANTRY 21 SF LVP 11 GUEST CLOSET 26 SF CARPET 13 LOFT 586 SF 14 FOYER 120 SF LVP 16 MECH. 56 SF CONCRETE 17 DINING 193 SF LVP 18 LIVING ROOM 262 SF LVP 20 KITCHEN 174 SF LVP 21 CL 6 SF LVP 22 LIN. CLO. 5 SF LVT NOTE: AREA'S ARE PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL FLOOR AREA'S PRIOR TO BIDDING AND CONSTRUCTION NOTE: VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION SCALE: 1/2" = 1'-0"1 TYP. WALL SECTION DOOR SCHEDULE Type To Room: Name Door CommentsWidth Height 2/10 X 6/8 BATH 2' - 10" 6' - 8" 1/4 x 6/8 BATH 1' - 4" 6' - 8" 36" x 80" DINING 3' - 0" 6' - 8" 3/0 X 6/8 FOYER 3' - 0" 6' - 8" 2/10 X 6/8 FOYER 2' - 10" 6' - 8" 2/0 x 6/8 FOYER 2' - 0" 6' - 8" 2/10 X 6/8 GUEST BEDROOM 2' - 10" 6' - 8" 3/0 x 6/8 KITCHEN 3' - 0" 6' - 8" 2/8 x 6/8 M. BA 2' - 8" 6' - 8" Interior - Double Sliding Glass Shower Door M. BA 5' - 0" 6' - 0" 2/8 x 6/8 M. CLOSET 2' - 8" 6' - 8" 3/0 x 6/8 MASTER BEDROOM 3' - 0" 6' - 8" 3/0 x 6/8 MUD/LAUN. 3' - 0" 6' - 8" 3/0 x 6/8 PCKT MUD/LAUN. 3' - 0" 6' - 8" 2/8 x 6/8 MUD/LAUN. 2' - 8" 6' - 8" 3/0 x 6/8 MUD/LAUN. 3' - 0" 6' - 8" 3/0 x 6/8 MUD/LAUN. 3' - 0" 6' - 8" 16'-0" x 8'-0" TWO CAR GARAGE 16' - 0" 8' - 0" 3/0 x 6/8 TWO CAR GARAGE 3' - 0" 6' - 8" NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL DOORS PRIOR TO BIDDING AND CONSTRUCTION NOTE: VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION WINDOW SCHEDULE Level From Room: Name Type Comments MAIN FLOOR 2929 TRSM MAIN FLOOR 2929 TRSM MAIN FLOOR 2959 CSMT E MAIN FLOOR 2959 CSMT E MAIN FLOOR DINING 2959 CSMT E MAIN FLOOR DINING 2959 CSMT E MAIN FLOOR DINING 2929 TRSM MAIN FLOOR GUEST BEDROOM 2959 CSMT E MAIN FLOOR GUEST BEDROOM 2959 CSMT E MAIN FLOOR GUEST BEDROOM 2959 CSMT E MAIN FLOOR LIVING ROOM 2929 TRSM MAIN FLOOR M. BA 2935 CSMT E3 MAIN FLOOR MASTER BEDROOM 2959 CSMT E MAIN FLOOR MASTER BEDROOM 2959 CSMT E MAIN FLOOR MASTER BEDROOM 2959 CSMT E MAIN FLOOR MASTER BEDROOM 2959 CSMT E MAIN FLOOR MUD/LAUN. 2929 TRSM MAIN FLOOR: 17 UPPER FLOOR 2929 TRSM Porch Gable UPPER FLOOR TWO CAR GARAGE 3353 CSMT E Garage Gable UPPER FLOOR TWO CAR GARAGE 2935 CSMT E3 Garage Gable UPPER FLOOR TWO CAR GARAGE 2935 CSMT E3 Garage Gable UPPER FLOOR: 4 Grand total: 21NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL WINDOWS PRIOR TO BIDDING AND CONSTRUCTION NOTE: VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION NOTE: GLASS SHOWER DOORS NOT INCLUDED IN SCHEDULE SCALE: 1/2" = 1'-0"4 TYP. COLUMN SCALE: 1" = 1'-0"2 TYP. ZERO ENTRY - GARAGE SCALE: 1" = 1'-0"3 TYP. ZERO ENTRY DETAIL - STOOP SCALE: 1/4" = 1'-0"5 KITCHEN ELEVATION 1 SCALE: 1/4" = 1'-0"6 KITCHEN ELEVATION 2 SCALE: 1/4" = 1'-0"7 KITCHEN ISLAND ELEVATION SCALE: 1/4" = 1'-0"8 KITCHEN OPTION B - ELEVATION 1 SCALE: 1/4" = 1'-0"9 KITCHEN OPTION B - ELEVATION 2 SCALE: 1/4" = 1'-0"11 MASTER BATH ELEVATION SCALE: 1/4" = 1'-0"10 BATH ELEVATION SCALE: 1" = 1'-0"12 TERMITE GUARD GENERAL NOTES B. Submit floor truss layouts showing beam locations, joist layout, locations of continuous duct chases, and maximum duct size in each chase. Allow designer five days for complete review. lumber package. Allow designer five days for complete review. manufacturer for review prior to ordering roof trusses and/or roof A. Submit roof truss and/or rafter layout plan as completed by the 12. SUBMITTALS 8. DOORS AND WINDOWS A. Exterior doors shall be selected by the Owner. B. House-to-garage doors shall be fire rated doors approved by governing codes. Face design to be selected by the Owner. C. Interior doors shall be selected by the Owner. D. Exterior windows by Pella Corp as selected by owner. E. Glazing in all doors and windows shall comply with governing codes. F. Install egress window units in accordance with governing codes. G. Door and window sizes indicated or drawings are as follows: "3/0x6/8" represents a door or window 3'-0" wide x 6'-8" high. Jamb depth to be coordinated by the Contractor. H. Finish hardware shall be selected by the owner. Install hardware in accordance with governing codes. 9. FINISHES A. Gypsum wallboard, unless noted otherwise, shall be provided as follows: 1. Exterior walls: One layer 1/2" regular wallboard to interior face. 2. Interior walls: One layer 1/2" regular wallboard each face. 3. Ceiling: One layer 5/8" regular wallboard. 4. Garage/House common wall: One layer 5/8" type "X" wallboard each face. 5. Baths: Water resistant wallboard at all walls and ceilings surrounding tubs and showers and as required by governing codes. Provide cement board as substrate for ceramic tile. B. Provide metal corner bead and trim at all locations recommended by the gypsum wallboard manufacturer. C. Tape, float, and sand joints and fasteners of gypsum wallboard with three coats of joint compound as required to obtain a uniformly smooth surface. D. Finishes shall be selected by the Owner. 10. PLUMBING, MECHANICAL, AND ELECTRICAL A. Plumbing, mechanical, and electrical information and layouts shown on the Drawings is schematic in design, and shall be reviewed by sub-contractors, suppliers, and building officials for compliance with governing codes and good common construction practices. The Architect shall be notified by the Contractor of any discrepancies prior to construction. B. Plumbing, mechanical, and electrical equipment shall be selected by the Owner. C. Design and installation of plumbing, mechanical, and electrical equipment shall be the responsibility of the appropriate licensed contractors and sub- contractors. Design shall be submitted for owner's review prior to ordering D. Service panels shall be selected by the electrical sub-contractor. E. All HVAC equipment shall be individually switched. F. All outdoor, bath, and garage and spa wall receptacles shall be provided with ground fault circuit protection in accordance with governing codes. G. Dryer vents shall be extended to the exterior. H. Provide plumbing vents in accordance with governing codes. Minimize number and locate for minimal visual impact. I. Install type and number of smoke detectors in accordance with governing codes & UL217. J. Connect water, gas, and electric services in accordance with governing codes. 11. MISCELLANEOUS and installation of equipment. exterior walls install plates over foam sill sealer. C. Unless noted otherwise, all slabs on grade shall be 4" thick, reinforced with 6x6 W1.4xW1.4 W.W.M., and placed over 4" minimum compacted sand or gravel fill. Interior slabs shall be placed over 6 mil. Stabilized polyethylene vapor barrier. Coordinate with radon removal procedures. D. Footing sizes shown are typical only for stated soil pressure and consistent compaction. Contractor shall be responsible for footings complying with A. Adhered masonry flashing must be installed at wall penetrations and terminations integrated with the WRB properly (when used), and installed in accordance with the to ensure a consistent overall project color on the wall. C. Install in accordance with manufacturer's installation instructions. Visit this page for http://ncmabr.org/pdfs/masterlibrary/MVMA%20Installation%20Guide%204th%20Edition%20web.pdf Consult manufacturer for proper installation instructions. modified mortar meeting ANSI A118.4 OR ANSI 118.15. F. Touch-up, repair or replace damaged stone before completion of project. A. All structural steel shall comply with appropriate ASTM Specifications as follows: ASTM A36, ASTM A53, ASTM A501, ASTM A307, and ASTM A. Lumber shall, in addition to complying with governing codes, comply with: 1. "Product Use Manual" of the Western Wood Products Association for selection and use of products included in that manual. 2. "Plywood Specification and Grade Guide" of the American Plywood 3. "Standard Specifications for Grades of California Redwood Lumber" of 4. American Wood Preservers Association standards and recommendations for fire-retardate and preservative pressure treated lumber and plywood. 5. Western Red Cedar Lumber Association standards and recommendations the Redwood Inspection Bureau for Redwood. for cedar. Association. D. Application details and mortar recommendations may vary depending on the stone style. E. All dry-stacked and large format standard stones must be applied using a polymer - 5. METALS A325. 6. WOOD AND PLASTICS the design requirements of specific soil conditions. of the stone veneer. Assure that all flashing and kickouts are corrosion resistant, local building code requirements. B. Product should be pulled from a variety of boxes and blended on site during intalllation installation instructions: 4. MASONRY Install skylights according to the manufactures' recommendations. I. Install water and ice barrier (Bituthene or equal) over roof sheathing at all eaves and valleys. water & ice barrier to extend 24" past outside face of L. Provide 2" nominal pressure treated lumber over foam sill sealer beneath full bearing of wood beams bearing on concrete or 7. THERMAL AND MOISTURE PROTECTION A. Provide thermal building insulation at assemblies adjacent to exterior or unheated spaces meeting the requirements of governing codes and, unless noted otherwise, meeting the following minimum requirements: 1. Foundations: 1 1/2"extruded polystyrene (R-10) 2. Walls: glass fiber batt (R-20) U.N.O. 3. Floors: glass fiber batt (R-30) -for floors over unconditioned space or exterior 4. Ceilings: glass fiber batt (R-49) 5. Install continuous blankets without holes for electrical boxes, lighting fixtures, or heating ductwork. B. Install 6 mil. stabilized polyethylene vapor barrier against interior face of all C. Waterproof foundation walls at excavated areas from footing to finished grade with two coats of asphalt based waterproofing compound for full basements. D. Roofing shall be 240 lb. (minimum) composition shingles installed over 15 lb. roof felt on roof sheathing. Minimum slope, fasteners, under layment, and exposure according to manufacturers' recommendations. E. Provide flashing and sheet metal required to prevent penetration of water through the exterior shell of the building. In addition to complying with governing codes, comply with pertinent recommendations contained in the current edition of "Architectural Sheet Metal Manual" published by SMCNA. All iron sheet metal flashing shall be hot-dipped galvanized complying with F. Provide gutters and downspouts to provide positive roof and site drainage. G. Provide attic and roof ventilation as required by governing codes and as shown on the Drawings. Provide appropriate soffit and roof vents. H. Skylights shall be selected by the Contractor and approved by the owner. ASTM A93. thermal insulation. masonry. 1. Before final Drawings and Specifications are issued for construction, they shall be submitted to all governing building agencies to insure their compliance with all applicable local and national codes. If code discrepancies in Drawings and/or Specifications appear, the Architect shall be notified of such discrepancies in writing by the Contractor or building official, and allowed to alter the drawings and specifications so as to comply with governing codes before construction begins. 2. Upon written receipt of approval from the governing official, approved final Drawings and Specifications shall be submitted to the Contractor by 3. If code discrepancies are discovered during the construction process, the Architect shall be notified and allowed ample time to remedy said 4. All work performed shall comply with all applicable local, state and national building codes, ordinances and regulations, and all other B. All contractors, suppliers, and fabricators shall be responsible for the content of the Drawings, and for the supply and design of appropriate C. All manufactured articles, materials, and equipment shall be handled, applied, installed, erected, used, cleaned, and conditioned in strict accordance with the D. All alternates are at the option of the Owner and shall be at the Owner's request, constructed in addition to or in lieu of the typical construction, as dead load 15psf (10 psf top, 5psf bottom) dead load 15psf (10 psf top, 5psf bottom) 5. Prior to start of construction, verify design loads with governing codes and site conditions. Check with local building agencies for wind, seismic, snow and other special loading conditions. If discrepancies are discovered, Architect shall be notified according to Section 1.A.1 above. A. Perform excavation, according to good common construction practices, to the lines, grades, and elevations indicated on the Drawings. B. Provide consistent compaction of the top 8" of sub-grade, fill, and backfill material beneath structures, walks, and pavements to meet the stated soil C. Provide soil poisoning to control termites as required by governing codes. D. Provide and install ventilation for Radon Gas as required by local building A. Provide concrete complying with ASTM C94. Unless otherwise noted, concrete shall have the following 28 day compressive strengths as minimums: 2. Concrete floor slabs, walks, drives, and patios: 3,500psi 3. Provide construction joints so panel size does not exceed 400sf. B. Provide reinforcement of the size and spacing indicated on Drawings. Reinforcing shall comply with the following minimums: live load 60psf (maximum) live load 40psf (maximum) live load 30psf (maximum) agencies and governing codes. 1. Concrete footings and foundations: 3,000psi 1. Bars: ASTM A615, grade 40, deformed bars. 2. Welded Wire Fabric: ASTM A185. 3. CONCRETE 2. SITE WORK pressure. materials and work performance. manufacturers' requirements. indicated on the Drawings. 3. Balconies and Decks: 4. Soil Pressure: 1500 psf (minimum) 2. Floor: 1. Roof: E. Design Loads: dead load 10psf 1. GENERAL REQUIREMENTS authorities having jurisdiction. discrepancies. the Architect. A. Codes: drawings to designer for review prior to construction. spacing of all trusses. Contractor to submit truss drawings and/or roof framing b. Install joist and beam hangers capable of supporting the maximum allowable load of joist or beam being supported. C. Provide "Micro-Lam" glue laminated veneer lumber beams (manufactured by Truss Joist Corporation) or equal, of the dimensions and number indicated on the drawings. Provide exterior grade Micro Lams for deck framing and other in strict accordance with manufacturers' recommendations. a. Modulus of elasticity: 2,000,000 psi b. Flexural (12" depth): 2,900 psi c. Horizontal shear: 285 psi D. Provide wood trusses able to sustain the stated loads for the spans, profiles, and arrangement shown on the Drawings. Truss layout is schematic only. Truss manufacturer and/or engineer shall be responsible for the design and E. All roof trusses shall be installed with metal truss seats as specified by the F. Unless noted otherwise, provide: 1. Double header joists and trimmers at all floor openings. 2. Double joists under all partitions parallel to joists. 3. Double 2x12 headers with 1/2 OSB between at all door and window openings in 2x4 walls. Triple 2x10 headers with 1/2" OSB between at all door and window openings at 2x6 walls. 4. For solid sawn joists, provide one row of 1x3 cross-bridging or metal bridging G. Stud spacing at all exterior and bearing walls shall be 16" o.c. minimum. H. Stud walls shall not exceed the following heights without continuous lateral support perpendicular to the plane of the wall at the stated height or less. Studs shall be continuous between points of lateral support. I. Unless noted otherwise, rafters, ceiling joists, collar ties, and purlins shall be sized and spaced in accordance with FHA requirements or governing codes, J. Stair construction shall consist of (3)2x12 stringers, 5/4" or 2x thick tread and 3/4" thick risers or, shall be fabricated by component manufacturer. K. All wood plates bearing on concrete or masonry shall be pressure treated. At b. 2x6: 12'-0' 2. Non-bearing walls: a. 2x4: 14'-0" b. 2x6: 20'-0" whichever is more restrictive. 1. Bearing walls: a. 2x4: 10'-0" for each 8'-0" of joist span. d. Bearing: 550 psi truss manufacturer. 1. Allowable stresses: B. Provide lumber and materials meeting or exceeding the following standards of a. Studs: Douglas Fir-Larch, Stud Grade -or as approved by building code. b. Headers and Beams: Douglas Fir-Larch, No. 2 and better -or as appoved by building code. 2. All headers and beams shall be free from splits, checks, and shakes. a. Roof: 1/2" OSB APA RATED SHEATHING, EXP 1. b. Walls: 1/2" OR 7/16" OSB APA RATED SHEATHING, EXP 1. c. Floor: 23/32" plywood APA RATED SHEATHING, EXP 1. d. Proper oriented strand board may be substituted for plywood. steel at exterior locations. a. Steel items: Comply with ASTM A36; use galvanized 3. Sheathing: (with clips) (glue and nail) 4. Rough Hardware: 1. Framing Members: quality: Contractor to submit steel shop drawings to designer or a licensed structural Construction and shall be detailed by a qualified structural steel detailer. B. All steel connections shall be designed according to AISC Manual of Steel engineer prior to steel erection. C. Architect will not be responsible for any errors in the roof and/or floor framing without the opportunity to review the roof and/or floor framing layouts. Framing layouts, member sizes, and floor/roof penetrations indicated on the drawings are for design intent only. Final layouts shall be the responsibility of builder. exterior applications. Unless noted otherwise, fasten multiple beams together exterior wall below. And as shown on the roof plan. A. This set of construction drawings is intended for design intent only. Although many jurisdictions will accept these drawings as sufficient for a construction permit, these drawings are not intended, and should not be construed, as a complete set of construction drawings. These drawings will have to be adapted to meet local zoning and/or site conditions and additional detailing will need to be completed on site by the builder. B. Install prefabricated fireplace units as shown on Drawings. 1. Fireplace units shall be "Heat-N-Glo" or as approved by Owner. 2. Contractor shall be responsible for proper installation as recommended by the manufacturer and as required by governing codes, including mantel and hearth design and location. C. Room sizes shown on the plans indicate room dimensions prior to installation of gypsum wall board. Gypsum wall board thickness must be subtracted from room sizes indicated for actual room dimensions and are subject to change. 2. Use exterior grade Micro-Lam in all areas subject to moisture. 3. Hearth shall be of non-combustible material. E. All excavations located beneath interior floor slabs (including garage) shall be inspected by a geotechnical engineer for bearing and the presence of unsuitable soils. If unsuitable soils are identified, the contractor shall follow the recommendations of the geotechnical engineer. F. All excavations located beneath footings and foundations shall be inspected by a geotechnical engineer for bearing and the presence of unsuitable soils. If unsuitable soils are identified, the contractor shall follow the recommendations of the geotechnical engineer. EARTH RIGID INSULATION CONCRETE BLOCK CONCRETE BRICK PLYWOOD STEEL OR STEEL STUD WALL BATT INSULATION GYPSUM BOARD GRAVEL WOOD OR WOOD STUD WALL SOUND INSULATION IN WALL MIN. (3) 2X SOLID BLOCKING BEARING WALL MATERIALS ELEVATION DRAWING NUMBER WALL TYPE SHEET NUMBER SHEET NUMBER SECTION DRAWING NUMBER DETAIL DRAWING NUMBER SHEET NUMBER POINT LOAD FROM ABOVE ELEVATION HEIGHT ELEVATION TYPE W2 SYMBOLS VINTAGE COOP PLAN INFORMATION PLAN OPTION: FOUNDATION: ROOF TRUSS: CARMEL ESTATE SLAB ON GRADE UPPER FLOOR BONUS ROOM FULL BASEMENT STANDARD ROOF TRUSSES 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : IS S U E D F O R : 11 - 2 3 - 2 0 FO R C O N S T R U C T I O N 11 - 3 0 - 2 0 RE V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 RE V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 OW N E R R E Q U E S T E D C H A N G E S A0 19-137.2 3-18-2021 MS P L A N LR KC VI N T A G E E S T A T E S - N O R T H L I B E R T Y CA R M E L E S T A T E P L A N V 1 TI T L E S H E E T SHEET LIST Sheet Number Sheet Name A0 TITLE SHEET A100 FOUNDATION PLAN A101 MAIN FLOOR PLAN A200 ELEVATIONS A201 DETAILS AREA SCHEDULE Level Name Area MAIN FLOOR MAIN FLOOR 1585 SF MAIN FLOOR GARAGE 557 SF Grand total: 2 2142 SF NOTE: THIS DRAWING IS AN ARTISTIC INTERPRETATION OF THE GENERAL APPEARANCE OF THE DESIGN. IT IS NOT INTENDED TO BE AN EXACT RENDITION. MAIN FLOOR 0" T.O.F. -6" B.O.F. -4' -0" W3W2 ***VERIFY ALL CHANGES IN WALL ELEVATION ON SITE. MAINTAIN 42" MINIMUM FROST PROTECTION AT ALL TIMES ***ALL FOUNDATION STEP- DOWNS TO BE DETERMINED ON SITE AS GRADE ALLOWS DROP T.O.F. @ O.H.D., VERIFY W/ GRADE 4' - 0 " 8" 6" 3' - 0 " 8" 8"8" 1' - 4"1' - 4" W1 6" 1' - 4" 3' - 6 " 8" CF 16 10 " 1' - 4" W4 6" 3' - 6 " 8" 8" 1' - 4"MA I N T A I N 4 2 " M I N . F R O S T PR O T E C T I O N A T A L L T I M E S 2' - 10"16' - 4"1' - 4"20' - 6" NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL NOTE: STEP FOOTINGS DOWN AS GRADE REQUIRES. MAINTAIN MINIMUM FROST PROTECTION AT ALL TIMES. NOTE: STEP FOUNDATION DOWN AS GRADE REQUIRES. MAINTAIN 42" MINIMUM FROST PROTECTION ON ALL FOOTINGS NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL STOOP ABOVE NOTE: CHANGES IN FOOTING AND FOUNDATION WALL ELEVATIONS ARE FOR DESIGN INTENT ONLY. ACTUAL ELEVATIONS SHALL BE VERIFIED W/FINAL GRADE DURING CONSTRUCTION. MAINTAIN 42" MINIMUM FROST PROTECTION ON ALL FOOTINGS. STEP DOWN FOOTING @ O.H.D. STOOP ABOVE 41' - 0" W2 W1 W1 W1 W1 W1 W1 W1 W1 W1 3' - 0 " 25 ' - 4 " 29 ' - 0 " 5' - 8 " 63 ' - 0 " 9' - 0"13' - 0"19' - 0" 41' - 0" NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL W4 W4 W4 W4 W4 W2 W2 W3 W1 W1 8" 39' - 8" 8" 8"20' - 8" 8" 5' - 8"12' - 8"8" 8' - 0 " 2' - 0 " 44 ' - 6 " 8' - 6 " 63 ' - 0 " 10" 2' - 10"16' - 4"2' - 10" W1 W1 TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL DOWEL STOOP SLAB TO FOUNDATION ELEVATION CHANGE -VERIFY ALL CHANGES IN WALL ELEVATION ON SITE -MAINTAIN 42" MINIMUM FROST PROTECTION AT ALL TIMES POST P20 FOOTING F30 F24 CF16 1'-8'' 2'-6'' 2'-0'' 1'-4'' DIA 2'-6'' 2'-0'' CONT 4'-0'' 1'-0'' 1'-0'' 10'' (2) #4 CONT. #4 AT 12" O.C. E.W. #4 AT 12" O.C. E.W. (2) #4 CONT. -NOT ALL TYPES ARE USED F36 3'-0'' 3'-0'' 1'-0'' #4 AT 12" O.C. E.W. 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A100 19-137.2 3-18-2021 MS P L A N ML K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y CA R M E L E S T A T E P L A N V 1 FO U N D A T I O N P L A N SCALE: 1/4" = 1'-0"2 FOOTING LEGEND SCALE: 1/4" = 1'-0"1 FOUNDATION PLAN FOUNDATION SCHEDULE Type Mark WALL FOOTING Width Unconnected Height Hotizontal Reinforcements Vertical Reinforcements Footing Width Footing Length Footing Depth Footing Reinforcing W1 8" 3' - 6" #4 @ TOP & BOT. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. W2 8" 4' - 0" #4 @ TOP & BOT. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. W3 8" 3' - 0" #4 @ TOP & BOT. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. W4 8" 3' - 6" #4 @ TOP & BOT. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. 4 A201 22' - 0"5' - 0"14' - 0" 8' - 6 " 25 ' - 1 0 " 5' - 4 1 / 2 " 4' - 3 " 11 ' - 0 1 / 2 " 3' - 0"16' - 0"3' - 0"2' - 6"2' - 6"7' - 3 1/8"6' - 8 7/8" W W.C. COVERED PORCH R/S R/ S R/S MUD/LAUN. MASTER BEDROOM BATH GUEST BEDROOM TWO CAR GARAGE 41' - 0" M. BA M. CLOSET LOCKERS W.C. 3/0 x 6/8 PCKT 2/ 8 x 6 / 8 2/ 8 x 6 / 8 2/8 x 6/8 3/0 x 6/8 3/ 0 x 6 / 8 2/10 X 6/8 2/ 1 0 X 6 / 8 3/ 0 X 6 / 8 3' - 9"5' - 3"13' - 0"19' - 0" 41' - 0" 3' - 0 " 25 ' - 4 " 5' - 8 1 / 2 " 2' - 1 " 8' - 8 " 6' - 0 1 / 2 " 6' - 6 " 5' - 8 " 63 ' - 0 " PANTRY 3/0 x 6/8 DBL FOYER GUEST CLOSET COVERED PORCH PLUMBING WALL AS REQ'D FOR W/D HOOKUPS 29 3 5 C S M T 29 5 9 C S M T 2959 CSMT 2959 CSMT 1' - 1 0 " 4' - 8 " 2' - 1 0 " 2' - 1 0 " 6"3' - 3"3' - 3"5' - 3 1/2"9' - 6"18' - 8 1/2"6" R/S 2' - 3"8' - 6"2' - 3" 6' - 1 1 / 4 " 5' - 8 " 2' - 1 0 " RO O F T R U S S A B V . @ 2 4 " O . C . G.T.A. EX . G R A D E L V L B M A B O V E 5359 FXD 2' - 10 1/2"8' - 1 1/2"8' - 0" 32 X 6 0 TU B / S H W R (2) 1 3/4 X 11 7/8 LVL HEADER ATTIC ACCESS ABOVE ROOF TRUSS ABV. @ 24" O.C. ROOF TRUSS ABV. @ 24" O.C. EX. GRADE LVL BM ABOVE 11 7 / 8 " F L O O R J O I S T S SP A C E P E R M F G R 2/ 1 0 X 6 / 8 RO O F T R U S S A B V . @ 2 4 " O . C . NOTE: WALLS AND CEILING TO BE FINISHED W/ 5/8" TYPE "X" FIRE CODE GYPSUM BOARD RO O F T R U S S A B V . @ 2 4 " O . C . MECH. 3/0 x 6/8 FLOOR DRAIN 14' - 5 1/2"2' - 0" 2' - 0 " 2' - 0 " 2959 CSMT3- DINING LIVING ROOM KITCHEN 2959 CSMT 2959 CSMT 3/ 0 X 6 / 8 3' - 3"5' - 5 1/2"12' - 3 1/2" 6' - 6"2' - 5"12' - 7"18' - 6"6" 6"12' - 9 1/2"8' - 4 1/2" 20' - 11 1/2"6"5' - 3"2' - 6 1/2"3' - 10 1/2"6' - 10 1/2"6" 2' - 0 " 10 ' - 6 " 3' - 7 " 7' - 2 1 / 2 " 2' - 0 " 6" 2' - 0 " 6" 8' - 6 1 / 2 " 4' - 3 " 2' - 4 1 / 2 " 3' - 0 " 25 ' - 4 " 6' - 1 0 1 / 2 " 5' - 3 1 / 2 " 8' - 6 1 / 2 " 7' - 4 " 25 ' - 3 1 / 2 " NOTE: DIMENSIONS AND ROOM SIZES ARE SHOWN FOR DESIGN INTENT ONLY. DUE TO CONSTRUCTION MEANS, METHODS AND TOLERANCES, ROOM SIZES ARE SUBJECT TO CHANGE WITHOUT NOTICE. BEAR TRUSSES ON HOUSE/GARAGE WALL NICHE HB FUR WALL OUT W/ 1/2" FURRING STRIPS 12" TRAY CLG. 12" TRAY CLG. OPTIONAL 12" TRAY OPTIONAL POCKET DOOR OPTIONAL POCKET DOOR FURNWH HB 2 A201 Sim 3 A201 Sim 55 ' - 0 " R/ S 2/ 0 x 6 / 8 1/4 X 6/8 29 5 9 C S M T 2' - 6 " 3' - 6 " 5' - 4 " 8 1 / 2 " DW SINK A101 3O.H.C. O. H . C . RANGE RE F O.H.C. 29 2 9 T R S M TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL SL O P E S L A B 6 " T O OV E R H E A D D O O R 0'-0" -0'-2" 2- 6" 5' - 8 " 2' - 0" CL LIN. CLO. 29 2 9 T R S M FULL HT. WALL 29 5 9 C S M T 2- A101 4 12 ' - 5 3 / 4 " 7' - 3 " P102 3(2 ) 1 3 / 4 x 1 1 7 / 8 L V L H D R (2 ) 1 3 / 4 x 1 1 7 / 8 L V L H D R A201 10 A201 11 A201 5 7 6 A201 LAV. LAV.LAV. DW MW HOOD D RI D G E RI D G E RI D G E ROOF NOTES: 2'-0" EAVE OVERHANG*** 1' - 6" GABLE RAKES*** 9:12 SLOPE SIDE TO SIDE*** 5:12 SLOPE FRONT TO BACK*** ***UNLESS NOTED OTHERWISE PROVIDE RIDGE, HIP AND SOFFIT VENTING TO COMPLY W/ GOVERNING CODES RI D G E OVERFRAMING AS REQ'D (TYPICAL SEE ELEVATIONS) 8" / 1 2 " SNOW AND ICE BARRIER ALONG ALL EAVES & RAKES 2' - 0" PAST OUTSIDE FACE OF FRAMING (TYPICAL @ ALL EXTERIOR EAVES) OUTSIDE FACE OF FRAMING BELOW 6 1/2" / 12"6 1/2" / 12" 6 1/2" / 12" 6 1/2" / 12" 1' - 0 " O.H.C. O. H . C . DW RANGE SINK RE F O.H.C. 2' - 3" 1/2" 3' - 0"3' - 3" 1 1/4" 2' - 6" 1 1/4" 3' - 3" 14' - 6" 1" 3' - 0 " 1" 2' - 6 " 2' - 6 " 3' - 0 " 1/ 2 " 2' - 3 " 13 ' - 5 1 / 2 " 1' - 0 " 1' - 1 " 2' - 1 " 1 1/2" 1' - 6"1' - 3"3' - 0"2' - 0"1" 1 1/2" 3/ 4 " 2' - 0 " 1' - 3 1 / 4 " 8' - 1" 3' - 4 " A201 5 7 6 A201 8 9 MW HOOD O. H . C . O . H . C . O . H . C . O.H.C.O.H.C. LAZY SUSAN W/ DOOR ATTACHED OP T . FP LIVING ROOM 29 2 9 T R S M 29 2 9 T R S M 2' - 7 " 2' - 2 " 5' - 0 " 2' - 2 " 2' - 0" 12" TRAY CLG. PANTRY 3' - 3" 1 1/4" 2' - 6" 1 1/4" 3' - 3" 9' - 2 1/2" 1' - 0 " 1' - 1 " 2' - 1 " 1" 3' - 0 " 1" 2' - 6 " 2' - 6 " 8' - 2 " RANGE SINK RE F DW 1 1/2"1' - 6"1' - 3"3' - 0"2' - 0"1"1 1/2" 8' - 1" 3/ 4 " 2' - 0 " 1' - 3 1 / 4 " MW HOODO.H.C.O.H.C. O. H . C . O . H . C . O . H . C . 3' - 4 " 3' - 0" 1' - 6"1' - 6" 1' - 1 0 1 / 2 " 1/2"5' - 0"1/2" 5' - 1" 1' - 1 0 1 / 2 " 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A101 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y CA R M E L E S T A T E P L A N V 1 MA I N F L O O R P L A N SCALE: 1/4" = 1'-0"1 MAIN FLOOR- 1500 FLOOR PLAN SCALE: 1/4" = 1'-0"2 ROOF PLAN SCALE: 1/4" = 1'-0"3 KITCHEN - OPTION B SCALE: 1/4" = 1'-0"4 FIREPLACE OPTION SCALE: 1/4" = 1'-0"5 CARMEL KITCHEN SCALE: 1/4" = 1'-0"6 CARMEL BATH SCALE: 1/4" = 1'-0"7 CARMEL MASTER BATH MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MAIN WIN. H.H. 6' -10" UPPER LEVEL PLT HT 18' -2 7/8" T5 CONCRETE SLOPE TO GRADE UPPER FLOOR 10' -1 3/4" L1 8' - 1 1 / 8 " 1' - 0 5 / 8 " 9' - 1 1 / 8 " UPPER WIN. H.H. 16' -9 3/4" T1 M2 M1 T2 6' - 8 " T5T5 L1 8' - 1 1 / 8 " 1' - 0 5 / 8 " 9' - 1 1 / 8 " T1 M2 M1 T2 6' - 8 " 10' - 0" F1 M2 C1 T5 +12" +0" F1 T4 T6 T4 B1 T4 T7 2535 FXD 2953 CSMT 2935 FXD M1 2535 FXD T6 F1 T7 1' - 6 " 4' - 0 " S4 B1 S4 B1T7 S4 B1 M2 S2S2 T6 S1 T1 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE S1 T2 F1 T5 T2 F1 S1 C1 M1 M2 S1 T1 T5 T2 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE L1 C1 F1 M1 M2 MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MAIN WIN. H.H. 6' -10" T.O.F. -6" B.O.F. -4' -0" T1 S1 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE M2 M1 R1 F1 M1 F1 F1C1 M2 FIREPLACE OPTION B TRANSOM WINDOWS 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A200 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y CA R M E L E S T A T E P L A N V 1 EL E V A T I O N S SCALE: 1/4" = 1'-0"1 FRONT SCALE: 1/4" = 1'-0"2 BACK SCALE: 1/8" = 1'-0"3 LEFT SCALE: 1/8" = 1'-0"4 RIGHT Keynote Legend Key Value Keynote Text B1 DECORATIVE BRACKET - FYPON CRAFTSMAN BRACKET BKT04X12X16RI C1 COLUMN WRAP - OR - TRIM OUT COLUMN F1 6" ALUMINUM FASCIA OR 6" ALUMINUM RAKE L1 EXTERIOR WALL LIGHT M1 MASONRY- CULTURED STONE M2 MASONRY- STONE CAP R1 LAMINATED ASPHALT ROOF SHINGLES S1 (LAP SIDING) HARDIE-PLANK SIDING-7" MAX EXPOSURE S2 (STUCCO PANEL) HARDIE PANEL S3 (BOARD AND BATTEN SIDING) VERTICAL SIDING AND HARDIE TRIM S4 (SHAKE SIDING) T1 PAINTED HARDIE CORNER TRIM T2 4" PAINTED TRIM T4 6" OVER 8" PAINTED TRIM T5 7" OVER 12" PAINTED TRIM T6 5/4 X 7" PAINTED TRIM T7 4" TRIM AT WINDOWS ON FRONT ELEVATION ONLY 1X3 BATTENS ON SMOOTH PANEL SIDING MAIN FLOOR 0'-0" TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL CONTINUOUS BEAD OF SEALANT 4"4" 2" 4" 2' - 0"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE GARAGE SLAB (SLOPE TO OVERHEAD DOOR) MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" T.O.F. -6" B.O.F. -4' -0" 9' - 9 1 / 8 " 3' - 4 " 8" 8' - 1 1 / 4 " 2" 11 7 / 8 " 8' - 3 1 / 4 " 4" 2" SIMPSON POST STANDOFF 6X6 TRTD TIMBER POST BLOCKING AS REQ'D PAINTED COLUMN TRIM STONE CAP SEE ROOF PLAN 36" PLASTIC ATTIC CHUTE SNOW AND ICE BARRIER EXTEND 24" PAST I.S. FACE OF EXTERIOR WALLS LAMINATED ASPHALT ROOF SHINGLES ON 15# ROOF FELT ON 1/2" O.S.B. SHEATHING MTL. DRIP 2X6 SUB-FASCIA ALUMINUM FASCIA & SOFFIT ON 2X4 LOOKOUTS @ 24" O.C. 7" OVER 12" PAINTED TRIM SEE ELEVATIONS FOR SIDING MATERIAL WEATHER RESISTANT BARRIER OVER 1/2" O.S.B. SHEATHING ON 2X6 WALL STUDS @16" O.C. R21 INSULATION 1/2" GYP. BD. ON 6MIL POLY VAPOR BARRIER FLASHING (ALL HORIZ. JOINTS) 2X6 SILL PLATE "TRTD" ON CLOSED CELL FOAM SILL SEALER R49 BLOWN INSULATION 12 SE E R O O F PL A N MAIN FLOOR 12 " E N E R G Y H E E L M I N . T.O.F. 0'-0" 0'-4" FOUNDATION WALL-REFER TO PLAN TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL MAIN FLOOR PLT. HT. 9'-1 1/8" HOLD ALL TRIM AND SIDING MIN. 6" ABOVE GRADE 9' - 1 1 / 8 " CONTINUOUS BEAD OF SEALANT 4"4" 4' - 0 " LINE OF GRADE (VARIES) 2" 4" 2' - 0" HOLD ALL TRIM AND SIDING MIN. 6" MIN. ABOVE GRADE MAIN FLOOR 0'-0" TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL CONTINUOUS BEAD OF SEALANT 4"4" 2" 2' - 0"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE SLAB (SLOPE AWAY FROM HOUSE) MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MW HOOD RANGE PANTRY 3' - 3"2' - 8 1/2"3' - 3" 9' - 2 1/2" 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 7' - 6 " 3' - 3" 1 1/4" 2' - 6" 1 1/4" 3' - 3" 9' - 2 1/2" MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 1" 2' - 6"2' - 6" 3' - 0"1"2' - 6"2' - 6" 6' - 0 " 1' - 6 " 7' - 6 " 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 7' - 6 " PANTRY REF MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 1"2' - 0"3' - 0"1' - 3"1' - 6" 7' - 10" 2' - 1 0 1 / 2 " 1 1 / 2 " 3' - 0 " DW MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8"3' - 3" 1 1/4" 2' - 6" 1 1/4" 3' - 3"3' - 0" 12' - 2 1/2" 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 7' - 6 " 2' - 6"3' - 3"2' - 8 1/2"3' - 3" 11' - 8 1/2" MW HOOD RANGE MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 1"3' - 0"1"2' - 6"2' - 6"2' - 6" 10' - 8" 1' - 6 " 6' - 0 " 7' - 6 " 1"3' - 0"1"2' - 6"2' - 6"3' - 0" 11' - 2" 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 7' - 6 " REF MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 1/2"5' - 0"1/2" 5' - 1" 1 1 / 2 " 2' - 1 0 1 / 2 " 3' - 0 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 1 1 / 2 " 2' - 1 0 1 / 2 " 3' - 0 " 3' - 0" 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A201 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y CA R M E L E S T A T E P L A N V 1 DE T A I L S ROOM FINISH SCHEDULE- OVERALL ROOM NO ROOM NAME AREA FLOOR BASE WALLS CEILING NOTESN E S W FINISH HEIGHT 1 GUEST BEDROOM 133 SF CARPET 2 BATH 53 SF LVT 3 MASTER BEDROOM 149 SF CARPET 4 MUD/LAUN. 87 SF LVP 5 TWO CAR GARAGE 522 SF CONCRETE 6 M. BA 92 SF LVT 7 M. CLOSET 53 SF CARPET 10 PANTRY 21 SF LVP 11 GUEST CLOSET 26 SF CARPET 13 LOFT 369 SF 14 FOYER 120 SF LVP 16 MECH. 56 SF CONCRETE 17 DINING 200 SF LVP 18 LIVING ROOM 262 SF LVP 20 KITCHEN 175 SF LVP 21 CL 6 SF LVP 22 LIN. CLO. 5 SF LVT NOTE: AREA'S ARE PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL FLOOR AREA'S PRIOR TO BIDDING AND CONSTRUCTION NOTE: VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION SCALE: 1" = 1'-0"2 TYP. ZERO ENTRY DETAIL - GARAGE DOOR SCHEDULE Type To Room: Name Door CommentsWidth Height 2/10 X 6/8 BATH 2' - 10" 6' - 8" 1/4 x 6/8 BATH 1' - 4" 6' - 8" 3/0 x 6/8 DINING 3' - 0" 6' - 8" 36" x 80" DINING 3' - 0" 6' - 8" 3/0 X 6/8 FOYER 3' - 0" 6' - 8" 2/10 X 6/8 FOYER 2' - 10" 6' - 8" 2/0 x 6/8 FOYER 2' - 0" 6' - 8" 2/10 X 6/8 GUEST BEDROOM 2' - 10" 6' - 8" 3/0 x 6/8 KITCHEN 3' - 0" 6' - 8" 2/8 x 6/8 M. BA 2' - 8" 6' - 8" Interior - Double Sliding Glass Shower Door M. BA 5' - 0" 6' - 0" 2/8 x 6/8 M. CLOSET 2' - 8" 6' - 8" 3/0 x 6/8 MUD/LAUN. 3' - 0" 6' - 8" 3/0 x 6/8 PCKT MUD/LAUN. 3' - 0" 6' - 8" 2/8 x 6/8 MUD/LAUN. 2' - 8" 6' - 8" 3/0 x 6/8 MUD/LAUN. 3' - 0" 6' - 8" 3/0 x 6/8 MUD/LAUN. 3' - 0" 6' - 8" 16'-0" x 8'-0" TWO CAR GARAGE 16' - 0" 8' - 0" 3/0 x 6/8 TWO CAR GARAGE 3' - 0" 6' - 8" NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL DOORS PRIOR TO BIDDING AND CONSTRUCTION NOTE: VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION WINDOW SCHEDULE Level From Room: Name Type Comments MAIN FLOOR 2929 TRSM MAIN FLOOR 2959 CSMT E MAIN FLOOR 2959 CSMT E MAIN FLOOR DINING 5359 FXD MAIN FLOOR DINING 2959 CSMT E MAIN FLOOR DINING 2959 CSMT E MAIN FLOOR DINING 2929 TRSM MAIN FLOOR GUEST BEDROOM 2959 CSMT E MAIN FLOOR GUEST BEDROOM 2959 CSMT E MAIN FLOOR GUEST BEDROOM 2959 CSMT E MAIN FLOOR LIVING ROOM 2929 TRSM MAIN FLOOR LIVING ROOM 2929 TRSM MAIN FLOOR M. BA 2935 CSMT E3 MAIN FLOOR MASTER BEDROOM 2959 CSMT E MAIN FLOOR MASTER BEDROOM 2959 CSMT E MAIN FLOOR MASTER BEDROOM 2959 CSMT E MAIN FLOOR MASTER BEDROOM 2959 CSMT E MAIN FLOOR MUD/LAUN. 2929 TRSM MAIN FLOOR: 18 UPPER FLOOR 2935 CSMT E3 PORCH GABLE UPPER FLOOR 2935 CSMT E3 GARAGE GABLE UPPER FLOOR 2953 CSMT E GARAGE GABLE UPPER FLOOR TWO CAR GARAGE 2935 CSMT E3 GARAGE GABLE UPPER FLOOR: 4 Grand total: 22 NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL WINDOWS PRIOR TO BIDDING AND CONSTRUCTION NOTE: VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION NOTE: GLASS SHOWER DOORS NOT INCLUDED IN SCHEDULE SCALE: 1/2" = 1'-0"4 TYP. COLUMN SCALE: 1/2" = 1'-0"1 WALL SECTION SCALE: 1" = 1'-0"3 TYP. ZERO ENTRY DETAIL - STOOP SCALE: 1/4" = 1'-0"5 KITCHEN ELEVATION 1 SCALE: 1/4" = 1'-0"6 KITCHEN ELEVATION 2 SCALE: 1/4" = 1'-0"7 KITCHEN ISLAND ELEVATION SCALE: 1/4" = 1'-0"8 KITCHEN OPTION B - ELEVATION 1 SCALE: 1/4" = 1'-0"9 KITCHEN OPTION B - ELEVATION 2 SCALE: 1/4" = 1'-0"11 MASTER BATH ELEVATION SCALE: 1/4" = 1'-0"10 BATH ELEVATION SCALE: 1" = 1'-0"12 TERMITE GUARD GENERAL NOTES B. Submit floor truss layouts showing beam locations, joist layout, locations of continuous duct chases, and maximum duct size in each chase. Allow designer five days for complete review. lumber package. Allow designer five days for complete review. manufacturer for review prior to ordering roof trusses and/or roof A. Submit roof truss and/or rafter layout plan as completed by the 12. SUBMITTALS 8. DOORS AND WINDOWS A. Exterior doors shall be selected by the Owner. B. House-to-garage doors shall be fire rated doors approved by governing codes. Face design to be selected by the Owner. C. Interior doors shall be selected by the Owner. D. Exterior windows by Pella Corp as selected by owner. E. Glazing in all doors and windows shall comply with governing codes. F. Install egress window units in accordance with governing codes. G. Door and window sizes indicated or drawings are as follows: "3/0x6/8" represents a door or window 3'-0" wide x 6'-8" high. Jamb depth to be coordinated by the Contractor. H. Finish hardware shall be selected by the owner. Install hardware in accordance with governing codes. 9. FINISHES A. Gypsum wallboard, unless noted otherwise, shall be provided as follows: 1. Exterior walls: One layer 1/2" regular wallboard to interior face. 2. Interior walls: One layer 1/2" regular wallboard each face. 3. Ceiling: One layer 5/8" regular wallboard. 4. Garage/House common wall: One layer 5/8" type "X" wallboard each face. 5. Baths: Water resistant wallboard at all walls and ceilings surrounding tubs and showers and as required by governing codes. Provide cement board as substrate for ceramic tile. B. Provide metal corner bead and trim at all locations recommended by the gypsum wallboard manufacturer. C. Tape, float, and sand joints and fasteners of gypsum wallboard with three coats of joint compound as required to obtain a uniformly smooth surface. D. Finishes shall be selected by the Owner. 10. PLUMBING, MECHANICAL, AND ELECTRICAL A. Plumbing, mechanical, and electrical information and layouts shown on the Drawings is schematic in design, and shall be reviewed by sub-contractors, suppliers, and building officials for compliance with governing codes and good common construction practices. The Architect shall be notified by the Contractor of any discrepancies prior to construction. B. Plumbing, mechanical, and electrical equipment shall be selected by the Owner. C. Design and installation of plumbing, mechanical, and electrical equipment shall be the responsibility of the appropriate licensed contractors and sub- contractors. Design shall be submitted for owner's review prior to ordering D. Service panels shall be selected by the electrical sub-contractor. E. All HVAC equipment shall be individually switched. F. All outdoor, bath, and garage and spa wall receptacles shall be provided with ground fault circuit protection in accordance with governing codes. G. Dryer vents shall be extended to the exterior. H. Provide plumbing vents in accordance with governing codes. Minimize number and locate for minimal visual impact. I. Install type and number of smoke detectors in accordance with governing codes & UL217. J. Connect water, gas, and electric services in accordance with governing codes. 11. MISCELLANEOUS and installation of equipment. exterior walls install plates over foam sill sealer. C. Unless noted otherwise, all slabs on grade shall be 4" thick, reinforced with 6x6 W1.4xW1.4 W.W.M., and placed over 4" minimum compacted sand or gravel fill. Interior slabs shall be placed over 6 mil. Stabilized polyethylene vapor barrier. Coordinate with radon removal procedures. D. Footing sizes shown are typical only for stated soil pressure and consistent compaction. Contractor shall be responsible for footings complying with A. Adhered masonry flashing must be installed at wall penetrations and terminations integrated with the WRB properly (when used), and installed in accordance with the to ensure a consistent overall project color on the wall. C. Install in accordance with manufacturer's installation instructions. Visit this page for http://ncmabr.org/pdfs/masterlibrary/MVMA%20Installation%20Guide%204th%20Edition%20web.pdf Consult manufacturer for proper installation instructions. modified mortar meeting ANSI A118.4 OR ANSI 118.15. F. Touch-up, repair or replace damaged stone before completion of project. A. All structural steel shall comply with appropriate ASTM Specifications as follows: ASTM A36, ASTM A53, ASTM A501, ASTM A307, and ASTM A. Lumber shall, in addition to complying with governing codes, comply with: 1. "Product Use Manual" of the Western Wood Products Association for selection and use of products included in that manual. 2. "Plywood Specification and Grade Guide" of the American Plywood 3. "Standard Specifications for Grades of California Redwood Lumber" of 4. American Wood Preservers Association standards and recommendations for fire-retardate and preservative pressure treated lumber and plywood. 5. Western Red Cedar Lumber Association standards and recommendations the Redwood Inspection Bureau for Redwood. for cedar. Association. D. Application details and mortar recommendations may vary depending on the stone style. E. All dry-stacked and large format standard stones must be applied using a polymer - 5. METALS A325. 6. WOOD AND PLASTICS the design requirements of specific soil conditions. of the stone veneer. Assure that all flashing and kickouts are corrosion resistant, local building code requirements. B. Product should be pulled from a variety of boxes and blended on site during intalllation installation instructions: 4. MASONRY Install skylights according to the manufactures' recommendations. I. Install water and ice barrier (Bituthene or equal) over roof sheathing at all eaves and valleys. water & ice barrier to extend 24" past outside face of L. Provide 2" nominal pressure treated lumber over foam sill sealer beneath full bearing of wood beams bearing on concrete or 7. THERMAL AND MOISTURE PROTECTION A. Provide thermal building insulation at assemblies adjacent to exterior or unheated spaces meeting the requirements of governing codes and, unless noted otherwise, meeting the following minimum requirements: 1. Foundations: 1 1/2"extruded polystyrene (R-10) 2. Walls: glass fiber batt (R-20) U.N.O. 3. Floors: glass fiber batt (R-30) -for floors over unconditioned space or exterior 4. Ceilings: glass fiber batt (R-49) 5. Install continuous blankets without holes for electrical boxes, lighting fixtures, or heating ductwork. B. Install 6 mil. stabilized polyethylene vapor barrier against interior face of all C. Waterproof foundation walls at excavated areas from footing to finished grade with two coats of asphalt based waterproofing compound for full basements. D. Roofing shall be 240 lb. (minimum) composition shingles installed over 15 lb. roof felt on roof sheathing. Minimum slope, fasteners, under layment, and exposure according to manufacturers' recommendations. E. Provide flashing and sheet metal required to prevent penetration of water through the exterior shell of the building. In addition to complying with governing codes, comply with pertinent recommendations contained in the current edition of "Architectural Sheet Metal Manual" published by SMCNA. All iron sheet metal flashing shall be hot-dipped galvanized complying with F. Provide gutters and downspouts to provide positive roof and site drainage. G. Provide attic and roof ventilation as required by governing codes and as shown on the Drawings. Provide appropriate soffit and roof vents. H. Skylights shall be selected by the Contractor and approved by the owner. ASTM A93. thermal insulation. masonry. 1. Before final Drawings and Specifications are issued for construction, they shall be submitted to all governing building agencies to insure their compliance with all applicable local and national codes. If code discrepancies in Drawings and/or Specifications appear, the Architect shall be notified of such discrepancies in writing by the Contractor or building official, and allowed to alter the drawings and specifications so as to comply with governing codes before construction begins. 2. Upon written receipt of approval from the governing official, approved final Drawings and Specifications shall be submitted to the Contractor by 3. If code discrepancies are discovered during the construction process, the Architect shall be notified and allowed ample time to remedy said 4. All work performed shall comply with all applicable local, state and national building codes, ordinances and regulations, and all other B. All contractors, suppliers, and fabricators shall be responsible for the content of the Drawings, and for the supply and design of appropriate C. All manufactured articles, materials, and equipment shall be handled, applied, installed, erected, used, cleaned, and conditioned in strict accordance with the D. All alternates are at the option of the Owner and shall be at the Owner's request, constructed in addition to or in lieu of the typical construction, as dead load 15psf (10 psf top, 5psf bottom) dead load 15psf (10 psf top, 5psf bottom) 5. Prior to start of construction, verify design loads with governing codes and site conditions. Check with local building agencies for wind, seismic, snow and other special loading conditions. If discrepancies are discovered, Architect shall be notified according to Section 1.A.1 above. A. Perform excavation, according to good common construction practices, to the lines, grades, and elevations indicated on the Drawings. B. Provide consistent compaction of the top 8" of sub-grade, fill, and backfill material beneath structures, walks, and pavements to meet the stated soil C. Provide soil poisoning to control termites as required by governing codes. D. Provide and install ventilation for Radon Gas as required by local building A. Provide concrete complying with ASTM C94. Unless otherwise noted, concrete shall have the following 28 day compressive strengths as minimums: 2. Concrete floor slabs, walks, drives, and patios: 3,500psi 3. Provide construction joints so panel size does not exceed 400sf. B. Provide reinforcement of the size and spacing indicated on Drawings. Reinforcing shall comply with the following minimums: live load 60psf (maximum) live load 40psf (maximum) live load 30psf (maximum) agencies and governing codes. 1. Concrete footings and foundations: 3,000psi 1. Bars: ASTM A615, grade 40, deformed bars. 2. Welded Wire Fabric: ASTM A185. 3. CONCRETE 2. SITE WORK pressure. materials and work performance. manufacturers' requirements. indicated on the Drawings. 3. Balconies and Decks: 4. Soil Pressure: 1500 psf (minimum) 2. Floor: 1. Roof: E. Design Loads: dead load 10psf 1. GENERAL REQUIREMENTS authorities having jurisdiction. discrepancies. the Architect. A. Codes: drawings to designer for review prior to construction. spacing of all trusses. Contractor to submit truss drawings and/or roof framing b. Install joist and beam hangers capable of supporting the maximum allowable load of joist or beam being supported. C. Provide "Micro-Lam" glue laminated veneer lumber beams (manufactured by Truss Joist Corporation) or equal, of the dimensions and number indicated on the drawings. Provide exterior grade Micro Lams for deck framing and other in strict accordance with manufacturers' recommendations. a. Modulus of elasticity: 2,000,000 psi b. Flexural (12" depth): 2,900 psi c. Horizontal shear: 285 psi D. Provide wood trusses able to sustain the stated loads for the spans, profiles, and arrangement shown on the Drawings. Truss layout is schematic only. Truss manufacturer and/or engineer shall be responsible for the design and E. All roof trusses shall be installed with metal truss seats as specified by the F. Unless noted otherwise, provide: 1. Double header joists and trimmers at all floor openings. 2. Double joists under all partitions parallel to joists. 3. Double 2x12 headers with 1/2 OSB between at all door and window openings in 2x4 walls. Triple 2x10 headers with 1/2" OSB between at all door and window openings at 2x6 walls. 4. For solid sawn joists, provide one row of 1x3 cross-bridging or metal bridging G. Stud spacing at all exterior and bearing walls shall be 16" o.c. minimum. H. Stud walls shall not exceed the following heights without continuous lateral support perpendicular to the plane of the wall at the stated height or less. Studs shall be continuous between points of lateral support. I. Unless noted otherwise, rafters, ceiling joists, collar ties, and purlins shall be sized and spaced in accordance with FHA requirements or governing codes, J. Stair construction shall consist of (3)2x12 stringers, 5/4" or 2x thick tread and 3/4" thick risers or, shall be fabricated by component manufacturer. K. All wood plates bearing on concrete or masonry shall be pressure treated. At b. 2x6: 12'-0' 2. Non-bearing walls: a. 2x4: 14'-0" b. 2x6: 20'-0" whichever is more restrictive. 1. Bearing walls: a. 2x4: 10'-0" for each 8'-0" of joist span. d. Bearing: 550 psi truss manufacturer. 1. Allowable stresses: B. Provide lumber and materials meeting or exceeding the following standards of a. Studs: Douglas Fir-Larch, Stud Grade -or as approved by building code. b. Headers and Beams: Douglas Fir-Larch, No. 2 and better -or as appoved by building code. 2. All headers and beams shall be free from splits, checks, and shakes. a. Roof: 1/2" OSB APA RATED SHEATHING, EXP 1. b. Walls: 1/2" OR 7/16" OSB APA RATED SHEATHING, EXP 1. c. Floor: 23/32" plywood APA RATED SHEATHING, EXP 1. d. Proper oriented strand board may be substituted for plywood. steel at exterior locations. a. Steel items: Comply with ASTM A36; use galvanized 3. Sheathing: (with clips) (glue and nail) 4. Rough Hardware: 1. Framing Members: quality: Contractor to submit steel shop drawings to designer or a licensed structural Construction and shall be detailed by a qualified structural steel detailer. B. All steel connections shall be designed according to AISC Manual of Steel engineer prior to steel erection. C. Architect will not be responsible for any errors in the roof and/or floor framing without the opportunity to review the roof and/or floor framing layouts. Framing layouts, member sizes, and floor/roof penetrations indicated on the drawings are for design intent only. Final layouts shall be the responsibility of builder. exterior applications. Unless noted otherwise, fasten multiple beams together exterior wall below. And as shown on the roof plan. A. This set of construction drawings is intended for design intent only. Although many jurisdictions will accept these drawings as sufficient for a construction permit, these drawings are not intended, and should not be construed, as a complete set of construction drawings. These drawings will have to be adapted to meet local zoning and/or site conditions and additional detailing will need to be completed on site by the builder. B. Install prefabricated fireplace units as shown on Drawings. 1. Fireplace units shall be "Heat-N-Glo" or as approved by Owner. 2. Contractor shall be responsible for proper installation as recommended by the manufacturer and as required by governing codes, including mantel and hearth design and location. C. Room sizes shown on the plans indicate room dimensions prior to installation of gypsum wall board. Gypsum wall board thickness must be subtracted from room sizes indicated for actual room dimensions and are subject to change. 2. Use exterior grade Micro-Lam in all areas subject to moisture. 3. Hearth shall be of non-combustible material. E. All excavations located beneath interior floor slabs (including garage) shall be inspected by a geotechnical engineer for bearing and the presence of unsuitable soils. If unsuitable soils are identified, the contractor shall follow the recommendations of the geotechnical engineer. F. All excavations located beneath footings and foundations shall be inspected by a geotechnical engineer for bearing and the presence of unsuitable soils. If unsuitable soils are identified, the contractor shall follow the recommendations of the geotechnical engineer. EARTH RIGID INSULATION CONCRETE BLOCK CONCRETE BRICK PLYWOOD STEEL OR STEEL STUD WALL BATT INSULATION GYPSUM BOARD GRAVEL WOOD OR WOOD STUD WALL SOUND INSULATION IN WALL MIN. (3) 2X SOLID BLOCKING BEARING WALL MATERIALS ELEVATION DRAWING NUMBER WALL TYPE SHEET NUMBER SHEET NUMBER SECTION DRAWING NUMBER DETAIL DRAWING NUMBER SHEET NUMBER POINT LOAD FROM ABOVE ELEVATION HEIGHT ELEVATION TYPE W2 SYMBOLS VINTAGE COOP PLAN INFORMATION PLAN OPTION: FOUNDATION: ROOF TRUSS: CARMEL ESTATE SLAB ON GRADE UPPER FLOOR BONUS ROOM FULL BASEMENT STANDARD ROOF TRUSSES 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : IS S U E D F O R : 11 - 2 3 - 2 0 FO R C O N S T R U C T I O N 11 - 3 0 - 2 0 RE V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 RE V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 OW N E R R E Q U E S T E D C H A N G E S A0 19-137.2 3-18-2021 MS P L A N LR KC VI N T A G E E S T A T E S - N O R T H L I B E R T Y CA R M E L E S T A T E P L A N V 2 TI T L E S H E E T SHEET LIST Sheet Number Sheet Name A0 TITLE SHEET A100 FOUNDATION PLAN A101 MAIN FLOOR PLAN A200 ELEVATIONS A201 DETAILS AREA SCHEDULE Level Name Area MAIN FLOOR MAIN FLOOR 1620 SF MAIN FLOOR GARAGE 557 SF Grand total: 2 2177 SF NOTE: THIS DRAWING IS AN ARTISTIC INTERPRETATION OF THE GENERAL APPEARANCE OF THE DESIGN. IT IS NOT INTENDED TO BE AN EXACT RENDITION. MAIN FLOOR 0" T.O.F. -6" B.O.F. -4' -0" W3W2 ***VERIFY ALL CHANGES IN WALL ELEVATION ON SITE. MAINTAIN 42" MINIMUM FROST PROTECTION AT ALL TIMES ***ALL FOUNDATION STEP- DOWNS TO BE DETERMINED ON SITE AS GRADE ALLOWS DROP T.O.F. @ O.H.D., VERIFY W/ GRADE 4' - 0 " 8" 6" 3' - 0 " 8" 8"8" 1' - 4"1' - 4" W1 6" 1' - 4" 3' - 6 " 8" CF 16 10 " 1' - 4" W4 6" 3' - 6 " 8" 8" 1' - 4"MA I N T A I N 4 2 " M I N . F R O S T PR O T E C T I O N A T A L L T I M E S 2' - 10"16' - 4"1' - 4"20' - 6" NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL NOTE: STEP FOOTINGS DOWN AS GRADE REQUIRES. MAINTAIN MINIMUM FROST PROTECTION AT ALL TIMES. NOTE: STEP FOUNDATION DOWN AS GRADE REQUIRES. MAINTAIN 42" MINIMUM FROST PROTECTION ON ALL FOOTINGS NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL STOOP ABOVE NOTE: CHANGES IN FOOTING AND FOUNDATION WALL ELEVATIONS ARE FOR DESIGN INTENT ONLY. ACTUAL ELEVATIONS SHALL BE VERIFIED W/FINAL GRADE DURING CONSTRUCTION. MAINTAIN 42" MINIMUM FROST PROTECTION ON ALL FOOTINGS. STEP DOWN FOOTING @ O.H.D. STOOP ABOVE 41' - 0" W2 W1 W1 W1 W1 W1 W1 W1 W1 W1 3' - 0 " 25 ' - 4 " 29 ' - 0 " 5' - 8 " 63 ' - 0 " 9' - 0"17' - 0"15' - 0" 41' - 0" NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL W4 W4 W4 W4 W4 W2 W2 W3 W1 W1 8" 39' - 8" 8" 8"20' - 8" 8" 5' - 8"12' - 8"8" 8' - 0 " 2' - 0 " 44 ' - 6 " 8' - 6 " 63 ' - 0 " 10" 2' - 10"16' - 4"2' - 10" W1 W1 TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL DOWEL STOOP SLAB TO FOUNDATION ELEVATION CHANGE -VERIFY ALL CHANGES IN WALL ELEVATION ON SITE -MAINTAIN 42" MINIMUM FROST PROTECTION AT ALL TIMES POST P20 FOOTING F30 F24 CF16 1'-8'' 2'-6'' 2'-0'' 1'-4'' DIA 2'-6'' 2'-0'' CONT 4'-0'' 1'-0'' 1'-0'' 10'' (2) #4 CONT. #4 AT 12" O.C. E.W. #4 AT 12" O.C. E.W. (2) #4 CONT. -NOT ALL TYPES ARE USED F36 3'-0'' 3'-0'' 1'-0'' #4 AT 12" O.C. E.W. 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A100 19-137.2 3-18-2021 MS P L A N ML K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y CA R M E L E S T A T E P L A N V 2 FO U N D A T I O N P L A N SCALE: 1/4" = 1'-0"2 FOOTING LEGEND SCALE: 1/4" = 1'-0"1 FOUNDATION PLAN FOUNDATION SCHEDULE Type Mark WALL FOOTING Width Unconnected Height Hotizontal Reinforcements Vertical Reinforcements Footing Width Footing Length Footing Depth Footing Reinforcing W1 8" 3' - 6" #4 @ TOP & BOT. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. W2 8" 4' - 0" #4 @ TOP & BOT. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. W3 8" 3' - 0" #4 @ TOP & BOT. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. W4 8" 3' - 6" #4 @ TOP & BOT. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. 4 A201 22' - 0"5' - 0"14' - 0" 34 ' - 4 " 5' - 4 1 / 2 " 4' - 3 " 11 ' - 0 1 / 2 " 3' - 0"16' - 0"3' - 0"2' - 6"2' - 6"7' - 3 1/8"6' - 8 7/8" W W.C. COVERED PORCH R/S R/ S R/S MUD/LAUN. MASTER BEDROOM BATH GUEST BEDROOM TWO CAR GARAGE 41' - 0" M. BA M. CLOSET LOCKERS W.C. 3/0 x 6/8 PCKT 2/ 8 x 6 / 8 2/ 8 x 6 / 8 2/8 x 6/8 3/ 0 x 6 / 8 2/10 X 6/8 2/ 1 0 X 6 / 8 3/ 0 X 6 / 8 9' - 0"17' - 0"15' - 0" 41' - 0" 3' - 0 " 25 ' - 4 " 5' - 8 1 / 2 " 2' - 1 " 8' - 8 " 6' - 0 1 / 2 " 6' - 6 " 5' - 8 " 63 ' - 0 " PANTRY 3/0 x 6/8 DBL FOYER GUEST CLOSET COVERED PORCH PLUMBING WALL AS REQ'D FOR W/D HOOKUPS 29 3 5 C S M T 29 5 9 C S M T 2959 CSMT 1' - 1 0 " 4' - 8 " 2' - 1 0 " 2' - 1 0 " 6"3' - 3"3' - 3"5' - 3 1/2"9' - 3 1/2"3' - 11"15' - 0"6" R/S 2' - 10"11' - 4"2' - 10"2' - 8"6' - 8"5' - 8" 6' - 1 1 / 4 " 5' - 8 " 2' - 1 0 " RO O F T R U S S A B V . @ 2 4 " O . C . G.T.A. EX . G R A D E L V L B M A B O V E 32 X 6 0 TU B / S H W R (2) 1 3/4 X 11 7/8 LVL HEADER ATTIC ACCESS ABOVE ROOF TRUSS ABV. @ 24" O.C. ROOF TRUSS ABV. @ 24" O.C. EX. GRADE LVL BM ABOVE 11 7 / 8 " F L O O R J O I S T S SP A C E P E R M F G R 2/ 1 0 X 6 / 8 RO O F T R U S S A B V . @ 2 4 " O . C . NOTE: WALLS AND CEILING TO BE FINISHED W/ 5/8" TYPE "X" FIRE CODE GYPSUM BOARD RO O F T R U S S A B V . @ 2 4 " O . C . MECH. 3/0 x 6/8 FLOOR DRAIN 14' - 6 1/2"2' - 0" 2' - 0 " 2' - 0 " 2959 CSMT3- DINING LIVING ROOM KITCHEN 3' - 3"5' - 5 1/2" 6' - 6"2' - 5"12' - 7"18' - 6"6" 6"12' - 9 1/2"8' - 4 1/2" 20' - 11 1/2"6"5' - 3"2' - 6 1/2"3' - 10 1/2"6' - 10 1/2"6" 2' - 0 " 10 ' - 6 1 / 2 " 3' - 7 " 7' - 2 1 / 2 " 2' - 0 " 6" 8' - 6 1 / 2 " 4' - 3 " 2' - 4 1 / 2 " 3' - 0 " 6' - 1 0 1 / 2 " 5' - 3 1 / 2 " 8' - 6 1 / 2 " 7' - 4 " 25 ' - 3 1 / 2 " NOTE: DIMENSIONS AND ROOM SIZES ARE SHOWN FOR DESIGN INTENT ONLY. DUE TO CONSTRUCTION MEANS, METHODS AND TOLERANCES, ROOM SIZES ARE SUBJECT TO CHANGE WITHOUT NOTICE. BEAR TRUSSES ON HOUSE/GARAGE WALL NICHE HB FUR WALL OUT W/ 1/2" FURRING STRIPS 12" TRAY CLG. 12" TRAY CLG. OPTIONAL 12" TRAY OPTIONAL POCKET DOOR OPTIONAL POCKET DOOR FURNWH HB 2 A201 Sim 3 A201 Sim 55 ' - 0 " R/ S 2/ 0 x 6 / 8 1/4 X 6/8 2' - 6 " 3' - 6 " 5' - 4 " 8 1 / 2 " DW SINK A101 3 O.H.C. O. H . C . RANGE RE F O.H.C. 29 2 9 T R S M TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL SL O P E S L A B 6 " T O OV E R H E A D D O O R 0'-0" -0'-2" 2- 3/ 0 X 6 / 8 3/0 x 6/8 2' - 0 " 2' - 0"2' - 0" 2' - 0 " 2' - 0" 2' - 0" 2' - 0 " 2959 CSMT 2959 CSMT 2959 CSMT 29 5 9 C S M T 1 3 5 .0 0 ° CL LIN. CLO. 29 2 9 T R S M FULL HT. WALL A101 4 12 ' - 5 3 / 4 " 7' - 3 " 25 ' - 4 " LAV. LAV.LAV. MW HOOD (2 ) 1 3 / 4 x 1 1 7 / 8 L V L H D R (2 ) 1 3 / 4 x 1 1 7 / 8 L V L H D R A201 5 7 6 A201 11 A201 10 D RI D G E RI D G E RI D G E ROOF NOTES: 2'-0" EAVE OVERHANG*** 1' - 6" GABLE RAKES*** 9:12 SLOPE SIDE TO SIDE*** 5:12 SLOPE FRONT TO BACK*** ***UNLESS NOTED OTHERWISE PROVIDE RIDGE, HIP AND SOFFIT VENTING TO COMPLY W/ GOVERNING CODES RI D G E OVERFRAMING AS REQ'D (TYPICAL SEE ELEVATIONS) 8" / 1 2 " SNOW AND ICE BARRIER ALONG ALL EAVES & RAKES 2' - 0" PAST OUTSIDE FACE OF FRAMING (TYPICAL @ ALL EXTERIOR EAVES) OUTSIDE FACE OF FRAMING BELOW 6 1/2" / 12"6 1/2" / 12" 6 1/2" / 12" 6 1/2" / 12" 1' - 0 " O.H.C. O. H . C . DW RANGE SINK RE F O.H.C. 2' - 3" 1/2" 3' - 0"3' - 3" 1 1/4" 2' - 6" 1 1/4" 3' - 0" 14' - 3" 1' - 0 " 1' - 1 " 2' - 1 " 1" 3' - 0 " 1" 2' - 6 " 2' - 6 " 3' - 0 " 1/ 2 " 2' - 3 " 13 ' - 5 1 / 2 " 1 1/2" 1' - 6"1' - 3"3' - 0"2' - 0"1"1 1/2" 3/ 4 " 2' - 0 " 1' - 3 1 / 4 " 3' - 4 " 8' - 1" MW HOOD A201 5 7 6 A201 8 9 O. H . C . O . H . C . O . H . C .O.H.C.O.H.C. LAZY SUSAN W/ DOOR ATTACHED 29 2 9 T R S M 29 2 9 T R S M OP T . FP LIVING ROOM 2' - 7 " 2' - 2 " 5' - 0 " 2' - 2 " 2' - 0" 12" TRAY CLG. DW SINK RANGE RE F MW HOOD PANTRY KITCHEN 3' - 3" 1 1/4" 2' - 6" 1 1/4" 3' - 0" 8' - 11 1/2" 1' - 0 " 1' - 1 " 2' - 1 " 1 1/2"1' - 6"1' - 3"3' - 0"2' - 0" 1" 1 1/2" 8' - 1" 1" 3' - 0 " 1" 2' - 6 " 2' - 6 " 8' - 2 " O.H.C.O.H.C. O. H . C . O . H . C . O . H . C . 3' - 4 " 3/ 4 " 2' - 0 " 1' - 3 1 / 4 " 1/2"5' - 0"1/2" 5' - 1" 1' - 1 0 1 / 2 " 3' - 0" 1' - 6"1' - 6" 1' - 1 0 1 / 2 " 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A101 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y CA R M E L E S T A T E P L A N V 2 MA I N F L O O R P L A N SCALE: 1/4" = 1'-0"1 MAIN FLOOR- 1500 FLOOR PLAN SCALE: 1/4" = 1'-0"2 ROOF PLAN SCALE: 1/4" = 1'-0"3 KITCHEN - OPTION B SCALE: 1/4" = 1'-0"4 FIREPLACE OPTION SCALE: 1/4" = 1'-0"5 CARMEL KITCHEN SCALE: 1/4" = 1'-0"6 CARMEL MASTER BATH SCALE: 1/4" = 1'-0"7 CARMEL BATH MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MAIN WIN. H.H. 6' -10" UPPER LEVEL PLT HT 18' -2 7/8" T5 CONCRETE SLOPE TO GRADE UPPER FLOOR 10' -1 3/4" L1 8' - 1 1 / 8 " 1' - 0 5 / 8 " 9' - 1 1 / 8 " UPPER WIN. H.H. 16' -9 3/4" T1 M2 M1 T2 6' - 8 " T5T5 L1 8' - 1 1 / 8 " 1' - 0 5 / 8 " 9' - 1 1 / 8 " T1 M2 M1 T2 6' - 8 " 10' - 0" F1 M2 C1 T5 +12" +0" F1 T4 T6 T4 B1 T4 T7 2535 FXD 2953 CSMT 2935 FXD M1 2535 FXD T6 F1 T7 1' - 6 " 4' - 0 " S4 B1 S4 B1T7 S4 B1 M2 S2S2 S1 T1 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE S1 T2 F1 T5 F1 S1T2 C1 M1 S1 T1 T5 T2 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE L1 C1 F1 M1 M2 MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MAIN WIN. H.H. 6' -10" T.O.F. -6" B.O.F. -4' -0" T1 S1 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE M2 M1 R1 F1 M1 F1 F1C1 M2 FIREPLACE OPTION B TRANSOM WINDOWS 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A200 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y CA R M E L E S T A T E P L A N V 2 EL E V A T I O N S SCALE: 1/4" = 1'-0"1 FRONT SCALE: 1/4" = 1'-0"2 BACK SCALE: 1/8" = 1'-0"3 LEFT SCALE: 1/8" = 1'-0"4 RIGHT Keynote Legend Key Value Keynote Text B1 DECORATIVE BRACKET - FYPON CRAFTSMAN BRACKET BKT04X12X16RI C1 COLUMN WRAP - OR - TRIM OUT COLUMN F1 6" ALUMINUM FASCIA OR 6" ALUMINUM RAKE L1 EXTERIOR WALL LIGHT M1 MASONRY- CULTURED STONE M2 MASONRY- STONE CAP R1 LAMINATED ASPHALT ROOF SHINGLES S1 (LAP SIDING) HARDIE-PLANK SIDING-7" MAX EXPOSURE S2 (STUCCO PANEL) HARDIE PANEL S3 (BOARD AND BATTEN SIDING) VERTICAL SIDING AND HARDIE TRIM S4 (SHAKE SIDING) T1 PAINTED HARDIE CORNER TRIM T2 4" PAINTED TRIM T4 6" OVER 8" PAINTED TRIM T5 7" OVER 12" PAINTED TRIM T6 5/4 X 7" PAINTED TRIM T7 4" TRIM AT WINDOWS ON FRONT ELEVATION ONLY 1X3 BATTENS ON SMOOTH PANEL SIDING MAIN FLOOR 0'-0" TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL CONTINUOUS BEAD OF SEALANT 4"4" 2" 4" 2' - 0"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE GARAGE SLAB (SLOPE TO OVERHEAD DOOR) MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" T.O.F. -6" B.O.F. -4' -0" 9' - 9 1 / 8 " 3' - 4 " 8" 8' - 1 1 / 4 " 2" 11 7 / 8 " 8' - 3 1 / 4 " 4" 2" SIMPSON POST STANDOFF 6X6 TRTD TIMBER POST BLOCKING AS REQ'D PAINTED COLUMN TRIM STONE CAP SEE ROOF PLAN 36" PLASTIC ATTIC CHUTE SNOW AND ICE BARRIER EXTEND 24" PAST I.S. FACE OF EXTERIOR WALLS LAMINATED ASPHALT ROOF SHINGLES ON 15# ROOF FELT ON 1/2" O.S.B. SHEATHING MTL. DRIP 2X6 SUB-FASCIA ALUMINUM FASCIA & SOFFIT ON 2X4 LOOKOUTS @ 24" O.C. 7" OVER 12" PAINTED TRIM SEE ELEVATIONS FOR SIDING MATERIAL WEATHER RESISTANT BARRIER OVER 1/2" O.S.B. SHEATHING ON 2X6 WALL STUDS @16" O.C. R21 INSULATION 1/2" GYP. BD. ON 6MIL POLY VAPOR BARRIER FLASHING (ALL HORIZ. JOINTS) 2X6 SILL PLATE "TRTD" ON CLOSED CELL FOAM SILL SEALER R49 BLOWN INSULATION 12 SE E R O O F PL A N MAIN FLOOR 12 " E N E R G Y H E E L M I N . T.O.F. 0'-0" 0'-4" FOUNDATION WALL-REFER TO PLAN TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL MAIN FLOOR PLT. HT. 9'-1 1/8" HOLD ALL TRIM AND SIDING MIN. 6" ABOVE GRADE 9' - 1 1 / 8 " CONTINUOUS BEAD OF SEALANT 4"4" 4' - 0 " LINE OF GRADE (VARIES) 2" 4" 2' - 0" HOLD ALL TRIM AND SIDING MIN. 6" MIN. ABOVE GRADE MAIN FLOOR 0'-0" TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL CONTINUOUS BEAD OF SEALANT 4"4" 2" 2' - 0"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE SLAB (SLOPE AWAY FROM HOUSE) MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MW HOOD RANGE 3' - 3" 1 1/4" 2' - 6" 1 1/4" 3' - 0" 8' - 11 1/2" 3' - 3"2' - 8 1/2"3' - 0" 8' - 11 1/2" 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 7' - 6 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" PANTRY REF 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 7' - 6 " 1"3' - 0"1"2' - 6"2' - 6" 8' - 2" 1' - 6 " 6' - 0 " 7' - 6 " 1"3' - 0"1"2' - 6"2' - 6" 8' - 2" MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" DW 1"2' - 0"3' - 0"1' - 3"1' - 6" 7' - 10" 2' - 1 0 1 / 2 " 1 1 / 2 " 3' - 0 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MW HOOD RANGE 3' - 0"3' - 3" 1 1/4" 2' - 6" 1 1/4" 3' - 0" 11' - 11 1/2" 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 7' - 6 " 2' - 6"3' - 3"2' - 8 1/2"3' - 0" 11' - 5 1/2" MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" REF 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 7' - 6 " 1"3' - 0"1"2' - 6"2' - 6"3' - 0" 11' - 2" 6' - 0 " 1' - 6 " 7' - 6 " 1"3' - 0"1"2' - 6"2' - 6"2' - 6" 10' - 8" MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 1/2"5' - 0"1/2" 5' - 1" 1 1 / 2 " 2' - 1 0 1 / 2 " 3' - 0 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 1 1 / 2 " 2' - 1 0 1 / 2 " 3' - 0 " 3' - 0" 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A201 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y CA R M E L E S T A T E P L A N V 2 DE T A I L S ROOM FINISH SCHEDULE- OVERALL ROOM NO ROOM NAME AREA FLOOR BASE WALLS CEILING NOTESN E S W FINISH HEIGHT 1 GUEST BEDROOM 133 SF CARPET 2 BATH 53 SF LVT 3 MASTER BEDROOM 193 SF CARPET 4 MUD/LAUN. 87 SF LVP 5 TWO CAR GARAGE 522 SF CONCRETE 6 M. BA 92 SF LVT 7 M. CLOSET 53 SF CARPET 10 PANTRY 21 SF LVP 11 GUEST CLOSET 26 SF CARPET 13 LOFT 369 SF 14 FOYER 120 SF LVP 16 MECH. 56 SF CONCRETE 17 DINING 193 SF LVP 18 LIVING ROOM 262 SF LVP 20 KITCHEN 173 SF LVP 21 CL 6 SF LVP 22 LIN. CLO. 5 SF LVT NOTE: AREA'S ARE PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL FLOOR AREA'S PRIOR TO BIDDING AND CONSTRUCTION NOTE: VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION SCALE: 1" = 1'-0"2 TYP. ZERO ENTRY DETAIL - GARAGE DOOR SCHEDULE Type To Room: Name Door CommentsWidth Height 2/10 X 6/8 BATH 2' - 10" 6' - 8" 1/4 x 6/8 BATH 1' - 4" 6' - 8" 36" x 80" DINING 3' - 0" 6' - 8" 3/0 X 6/8 FOYER 3' - 0" 6' - 8" 2/10 X 6/8 FOYER 2' - 10" 6' - 8" 2/0 x 6/8 FOYER 2' - 0" 6' - 8" 2/10 X 6/8 GUEST BEDROOM 2' - 10" 6' - 8" 3/0 x 6/8 KITCHEN 3' - 0" 6' - 8" 2/8 x 6/8 M. BA 2' - 8" 6' - 8" Interior - Double Sliding Glass Shower Door M. BA 5' - 0" 6' - 0" 2/8 x 6/8 M. CLOSET 2' - 8" 6' - 8" 3/0 x 6/8 MASTER BEDROOM 3' - 0" 6' - 8" 3/0 x 6/8 MUD/LAUN. 3' - 0" 6' - 8" 3/0 x 6/8 PCKT MUD/LAUN. 3' - 0" 6' - 8" 2/8 x 6/8 MUD/LAUN. 2' - 8" 6' - 8" 3/0 x 6/8 MUD/LAUN. 3' - 0" 6' - 8" 3/0 x 6/8 MUD/LAUN. 3' - 0" 6' - 8" 16'-0" x 8'-0" TWO CAR GARAGE 16' - 0" 8' - 0" 3/0 x 6/8 TWO CAR GARAGE 3' - 0" 6' - 8" NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL DOORS PRIOR TO BIDDING AND CONSTRUCTION NOTE: VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION WINDOW SCHEDULE Level From Room: Name Type Comments MAIN FLOOR 2929 TRSM MAIN FLOOR 2959 CSMT E MAIN FLOOR 2959 CSMT E MAIN FLOOR DINING 2929 TRSM MAIN FLOOR DINING 2959 CSMT E MAIN FLOOR DINING 2959 CSMT E MAIN FLOOR GUEST BEDROOM 2959 CSMT E MAIN FLOOR GUEST BEDROOM 2959 CSMT E MAIN FLOOR GUEST BEDROOM 2959 CSMT E MAIN FLOOR LIVING ROOM 2929 TRSM MAIN FLOOR LIVING ROOM 2929 TRSM MAIN FLOOR M. BA 2935 CSMT E3 MAIN FLOOR MASTER BEDROOM 2959 CSMT E MAIN FLOOR MASTER BEDROOM 2959 CSMT E MAIN FLOOR MASTER BEDROOM 2959 CSMT E MAIN FLOOR MASTER BEDROOM 2959 CSMT E MAIN FLOOR MUD/LAUN. 2929 TRSM MAIN FLOOR: 17 UPPER FLOOR 2935 CSMT E3 PORCH GABLE UPPER FLOOR 2935 CSMT E3 GARAGE GABLE UPPER FLOOR 2953 CSMT E GARAGE GABLE UPPER FLOOR TWO CAR GARAGE 2935 CSMT E3 GARAGE GABLE UPPER FLOOR: 4 Grand total: 21 NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL WINDOWS PRIOR TO BIDDING AND CONSTRUCTION NOTE: VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION NOTE: GLASS SHOWER DOORS NOT INCLUDED IN SCHEDULE SCALE: 1/2" = 1'-0"4 TYP. COLUMN SCALE: 1/2" = 1'-0"1 WALL SECTION SCALE: 1" = 1'-0"3 TYP. ZERO ENTRY DETAIL - STOOP SCALE: 1/4" = 1'-0"5 KITCHEN ELEVATION 1 SCALE: 1/4" = 1'-0"6 KITCHEN ELEVATION 2 SCALE: 1/4" = 1'-0"7 KITCHEN ISLAND ELEVATION SCALE: 1/4" = 1'-0"8 KITCHEN OPTION B - ELEVATION 1 SCALE: 1/4" = 1'-0"9 KITCHEN OPTION B - ELEVATION 2 SCALE: 1/4" = 1'-0"11 MASTER BATH ELEVATION SCALE: 1/4" = 1'-0"10 BATH ELEVATION SCALE: 1" = 1'-0"12 TERMITE GUARD GENERAL NOTES B. Submit floor truss layouts showing beam locations, joist layout, locations of continuous duct chases, and maximum duct size in each chase. Allow designer five days for complete review. lumber package. Allow designer five days for complete review. manufacturer for review prior to ordering roof trusses and/or roof A. Submit roof truss and/or rafter layout plan as completed by the 12. SUBMITTALS 8. DOORS AND WINDOWS A. Exterior doors shall be selected by the Owner. B. House-to-garage doors shall be fire rated doors approved by governing codes. Face design to be selected by the Owner. C. Interior doors shall be selected by the Owner. D. Exterior windows by Pella Corp as selected by owner. E. Glazing in all doors and windows shall comply with governing codes. F. Install egress window units in accordance with governing codes. G. Door and window sizes indicated or drawings are as follows: "3/0x6/8" represents a door or window 3'-0" wide x 6'-8" high. Jamb depth to be coordinated by the Contractor. H. Finish hardware shall be selected by the owner. Install hardware in accordance with governing codes. 9. FINISHES A. Gypsum wallboard, unless noted otherwise, shall be provided as follows: 1. Exterior walls: One layer 1/2" regular wallboard to interior face. 2. Interior walls: One layer 1/2" regular wallboard each face. 3. Ceiling: One layer 5/8" regular wallboard. 4. Garage/House common wall: One layer 5/8" type "X" wallboard each face. 5. Baths: Water resistant wallboard at all walls and ceilings surrounding tubs and showers and as required by governing codes. Provide cement board as substrate for ceramic tile. B. Provide metal corner bead and trim at all locations recommended by the gypsum wallboard manufacturer. C. Tape, float, and sand joints and fasteners of gypsum wallboard with three coats of joint compound as required to obtain a uniformly smooth surface. D. Finishes shall be selected by the Owner. 10. PLUMBING, MECHANICAL, AND ELECTRICAL A. Plumbing, mechanical, and electrical information and layouts shown on the Drawings is schematic in design, and shall be reviewed by sub-contractors, suppliers, and building officials for compliance with governing codes and good common construction practices. The Architect shall be notified by the Contractor of any discrepancies prior to construction. B. Plumbing, mechanical, and electrical equipment shall be selected by the Owner. C. Design and installation of plumbing, mechanical, and electrical equipment shall be the responsibility of the appropriate licensed contractors and sub- contractors. Design shall be submitted for owner's review prior to ordering D. Service panels shall be selected by the electrical sub-contractor. E. All HVAC equipment shall be individually switched. F. All outdoor, bath, and garage and spa wall receptacles shall be provided with ground fault circuit protection in accordance with governing codes. G. Dryer vents shall be extended to the exterior. H. Provide plumbing vents in accordance with governing codes. Minimize number and locate for minimal visual impact. I. Install type and number of smoke detectors in accordance with governing codes & UL217. J. Connect water, gas, and electric services in accordance with governing codes. 11. MISCELLANEOUS and installation of equipment. exterior walls install plates over foam sill sealer. C. Unless noted otherwise, all slabs on grade shall be 4" thick, reinforced with 6x6 W1.4xW1.4 W.W.M., and placed over 4" minimum compacted sand or gravel fill. Interior slabs shall be placed over 6 mil. Stabilized polyethylene vapor barrier. Coordinate with radon removal procedures. D. Footing sizes shown are typical only for stated soil pressure and consistent compaction. Contractor shall be responsible for footings complying with A. Adhered masonry flashing must be installed at wall penetrations and terminations integrated with the WRB properly (when used), and installed in accordance with the to ensure a consistent overall project color on the wall. C. Install in accordance with manufacturer's installation instructions. Visit this page for http://ncmabr.org/pdfs/masterlibrary/MVMA%20Installation%20Guide%204th%20Edition%20web.pdf Consult manufacturer for proper installation instructions. modified mortar meeting ANSI A118.4 OR ANSI 118.15. F. Touch-up, repair or replace damaged stone before completion of project. A. All structural steel shall comply with appropriate ASTM Specifications as follows: ASTM A36, ASTM A53, ASTM A501, ASTM A307, and ASTM A. Lumber shall, in addition to complying with governing codes, comply with: 1. "Product Use Manual" of the Western Wood Products Association for selection and use of products included in that manual. 2. "Plywood Specification and Grade Guide" of the American Plywood 3. "Standard Specifications for Grades of California Redwood Lumber" of 4. American Wood Preservers Association standards and recommendations for fire-retardate and preservative pressure treated lumber and plywood. 5. Western Red Cedar Lumber Association standards and recommendations the Redwood Inspection Bureau for Redwood. for cedar. Association. D. Application details and mortar recommendations may vary depending on the stone style. E. All dry-stacked and large format standard stones must be applied using a polymer - 5. METALS A325. 6. WOOD AND PLASTICS the design requirements of specific soil conditions. of the stone veneer. Assure that all flashing and kickouts are corrosion resistant, local building code requirements. B. Product should be pulled from a variety of boxes and blended on site during intalllation installation instructions: 4. MASONRY Install skylights according to the manufactures' recommendations. I. Install water and ice barrier (Bituthene or equal) over roof sheathing at all eaves and valleys. water & ice barrier to extend 24" past outside face of L. Provide 2" nominal pressure treated lumber over foam sill sealer beneath full bearing of wood beams bearing on concrete or 7. THERMAL AND MOISTURE PROTECTION A. Provide thermal building insulation at assemblies adjacent to exterior or unheated spaces meeting the requirements of governing codes and, unless noted otherwise, meeting the following minimum requirements: 1. Foundations: 1 1/2"extruded polystyrene (R-10) 2. Walls: glass fiber batt (R-20) U.N.O. 3. Floors: glass fiber batt (R-30) -for floors over unconditioned space or exterior 4. Ceilings: glass fiber batt (R-49) 5. Install continuous blankets without holes for electrical boxes, lighting fixtures, or heating ductwork. B. Install 6 mil. stabilized polyethylene vapor barrier against interior face of all C. Waterproof foundation walls at excavated areas from footing to finished grade with two coats of asphalt based waterproofing compound for full basements. D. Roofing shall be 240 lb. (minimum) composition shingles installed over 15 lb. roof felt on roof sheathing. Minimum slope, fasteners, under layment, and exposure according to manufacturers' recommendations. E. Provide flashing and sheet metal required to prevent penetration of water through the exterior shell of the building. In addition to complying with governing codes, comply with pertinent recommendations contained in the current edition of "Architectural Sheet Metal Manual" published by SMCNA. All iron sheet metal flashing shall be hot-dipped galvanized complying with F. Provide gutters and downspouts to provide positive roof and site drainage. G. Provide attic and roof ventilation as required by governing codes and as shown on the Drawings. Provide appropriate soffit and roof vents. H. Skylights shall be selected by the Contractor and approved by the owner. ASTM A93. thermal insulation. masonry. 1. Before final Drawings and Specifications are issued for construction, they shall be submitted to all governing building agencies to insure their compliance with all applicable local and national codes. If code discrepancies in Drawings and/or Specifications appear, the Architect shall be notified of such discrepancies in writing by the Contractor or building official, and allowed to alter the drawings and specifications so as to comply with governing codes before construction begins. 2. Upon written receipt of approval from the governing official, approved final Drawings and Specifications shall be submitted to the Contractor by 3. If code discrepancies are discovered during the construction process, the Architect shall be notified and allowed ample time to remedy said 4. All work performed shall comply with all applicable local, state and national building codes, ordinances and regulations, and all other B. All contractors, suppliers, and fabricators shall be responsible for the content of the Drawings, and for the supply and design of appropriate C. All manufactured articles, materials, and equipment shall be handled, applied, installed, erected, used, cleaned, and conditioned in strict accordance with the D. All alternates are at the option of the Owner and shall be at the Owner's request, constructed in addition to or in lieu of the typical construction, as dead load 15psf (10 psf top, 5psf bottom) dead load 15psf (10 psf top, 5psf bottom) 5. Prior to start of construction, verify design loads with governing codes and site conditions. Check with local building agencies for wind, seismic, snow and other special loading conditions. If discrepancies are discovered, Architect shall be notified according to Section 1.A.1 above. A. Perform excavation, according to good common construction practices, to the lines, grades, and elevations indicated on the Drawings. B. Provide consistent compaction of the top 8" of sub-grade, fill, and backfill material beneath structures, walks, and pavements to meet the stated soil C. Provide soil poisoning to control termites as required by governing codes. D. Provide and install ventilation for Radon Gas as required by local building A. Provide concrete complying with ASTM C94. Unless otherwise noted, concrete shall have the following 28 day compressive strengths as minimums: 2. Concrete floor slabs, walks, drives, and patios: 3,500psi 3. Provide construction joints so panel size does not exceed 400sf. B. Provide reinforcement of the size and spacing indicated on Drawings. Reinforcing shall comply with the following minimums: live load 60psf (maximum) live load 40psf (maximum) live load 30psf (maximum) agencies and governing codes. 1. Concrete footings and foundations: 3,000psi 1. Bars: ASTM A615, grade 40, deformed bars. 2. Welded Wire Fabric: ASTM A185. 3. CONCRETE 2. SITE WORK pressure. materials and work performance. manufacturers' requirements. indicated on the Drawings. 3. Balconies and Decks: 4. Soil Pressure: 1500 psf (minimum) 2. Floor: 1. Roof: E. Design Loads: dead load 10psf 1. GENERAL REQUIREMENTS authorities having jurisdiction. discrepancies. the Architect. A. Codes: drawings to designer for review prior to construction. spacing of all trusses. Contractor to submit truss drawings and/or roof framing b. Install joist and beam hangers capable of supporting the maximum allowable load of joist or beam being supported. C. Provide "Micro-Lam" glue laminated veneer lumber beams (manufactured by Truss Joist Corporation) or equal, of the dimensions and number indicated on the drawings. Provide exterior grade Micro Lams for deck framing and other in strict accordance with manufacturers' recommendations. a. Modulus of elasticity: 2,000,000 psi b. Flexural (12" depth): 2,900 psi c. Horizontal shear: 285 psi D. Provide wood trusses able to sustain the stated loads for the spans, profiles, and arrangement shown on the Drawings. Truss layout is schematic only. Truss manufacturer and/or engineer shall be responsible for the design and E. All roof trusses shall be installed with metal truss seats as specified by the F. Unless noted otherwise, provide: 1. Double header joists and trimmers at all floor openings. 2. Double joists under all partitions parallel to joists. 3. Double 2x12 headers with 1/2 OSB between at all door and window openings in 2x4 walls. Triple 2x10 headers with 1/2" OSB between at all door and window openings at 2x6 walls. 4. For solid sawn joists, provide one row of 1x3 cross -bridging or metal bridging G. Stud spacing at all exterior and bearing walls shall be 16" o.c. minimum. H. Stud walls shall not exceed the following heights without continuous lateral support perpendicular to the plane of the wall at the stated height or less. Studs shall be continuous between points of lateral support. I. Unless noted otherwise, rafters, ceiling joists, collar ties, and purlins shall be sized and spaced in accordance with FHA requirements or governing codes, J. Stair construction shall consist of (3)2x12 stringers, 5/4" or 2x thick tread and 3/4" thick risers or, shall be fabricated by component manufacturer. K. All wood plates bearing on concrete or masonry shall be pressure treated. At b. 2x6: 12'-0' 2. Non-bearing walls: a. 2x4: 14'-0" b. 2x6: 20'-0" whichever is more restrictive. 1. Bearing walls: a. 2x4: 10'-0" for each 8'-0" of joist span. d. Bearing: 550 psi truss manufacturer. 1. Allowable stresses: B. Provide lumber and materials meeting or exceeding the following standards of a. Studs: Douglas Fir-Larch, Stud Grade -or as approved by building code. b. Headers and Beams: Douglas Fir -Larch, No. 2 and better -or as appoved by building code. 2. All headers and beams shall be free from splits, checks, and shakes. a. Roof: 1/2" OSB APA RATED SHEATHING, EXP 1. b. Walls: 1/2" OR 7/16" OSB APA RATED SHEATHING, EXP 1. c. Floor: 23/32" plywood APA RATED SHEATHING, EXP 1. d. Proper oriented strand board may be substituted for plywood. steel at exterior locations. a. Steel items: Comply with ASTM A36; use galvanized 3. Sheathing: (with clips) (glue and nail) 4. Rough Hardware: 1. Framing Members: quality: Contractor to submit steel shop drawings to designer or a licensed structural Construction and shall be detailed by a qualified structural steel detailer. B. All steel connections shall be designed according to AISC Manual of Steel engineer prior to steel erection. C. Architect will not be responsible for any errors in the roof and/or floor framing without the opportunity to review the roof and/or floor framing layouts. Framing layouts, member sizes, and floor/roof penetrations indicated on the drawings are for design intent only. Final layouts shall be the responsibility of builder. exterior applications. Unless noted otherwise, fasten multiple beams together exterior wall below. And as shown on the roof plan. A. This set of construction drawings is intended for design intent only. Although many jurisdictions will accept these drawings as sufficient for a construction permit, these drawings are not intended, and should not be construed, as a complete set of construction drawings. These drawings will have to be adapted to meet local zoning and/or site conditions and additional detailing will need to be completed on site by the builder. B. Install prefabricated fireplace units as shown on Drawings. 1. Fireplace units shall be "Heat-N-Glo" or as approved by Owner. 2. Contractor shall be responsible for proper installation as recommended by the manufacturer and as required by governing codes, including mantel and hearth design and location. C. Room sizes shown on the plans indicate room dimensions prior to installation of gypsum wall board. Gypsum wall board thickness must be subtracted from room sizes indicated for actual room dimensions and are subject to change. 2. Use exterior grade Micro-Lam in all areas subject to moisture. 3. Hearth shall be of non-combustible material. EARTH RIGID INSULATION CONCRETE BLOCK CONCRETE BRICK PLYWOOD STEEL OR STEEL STUD WALL BATT INSULATION GYPSUM BOARD GRAVEL WOOD OR WOOD STUD WALL SOUND INSULATION IN WALL MIN. (3) 2X SOLID BLOCKING BEARING WALL MATERIALS ELEVATION DRAWING NUMBER WALL TYPE SHEET NUMBER SHEET NUMBER SECTION DRAWING NUMBER DETAIL DRAWING NUMBER SHEET NUMBER POINT LOAD FROM ABOVE ELEVATION HEIGHT ELEVATION TYPE W2 SYMBOLS VINTAGE COOP PLAN INFORMATION PLAN OPTION: FOUNDATION: ROOF TRUSS: MENDOCINO ESTATE SLAB ON GRADE UPPER FLOOR BONUS ROOM FULL BASEMENT STANDARD ROOF TRUSSES 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : IS S U E D F O R : 11 - 2 3 - 2 0 FO R C O N S T R U C T I O N 11 - 3 0 - 2 0 RE V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 RE V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 OW N E R R E Q U E S T E D C H A N G E S A0 19-137.2 3-18-2021 MS P L A N LR KC VI N T A G E E S T A T E S - N O R T H L I B E R T Y ME N D O C I N O E S T A T E V 1 TI T L E S H E E T SHEET LIST Sheet Number Sheet Name A0 TITLE SHEET A100 FOUNDATION PLAN A101 MAIN FLOOR PLAN A200 ELEVATIONS A201 DETAILS AREA SCHEDULE Level Name Area MAIN FLOOR MAIN FLOOR 1989 SF MAIN FLOOR GARAGE 502 SF Grand total: 2 2491 SF NOTE: THIS DRAWING IS AN ARTISTIC INTERPRETATION OF THE GENERAL APPEARANCE OF THE DESIGN. IT IS NOT INTENDED TO BE AN EXACT RENDITION. MAIN FLOOR 0" T.O.F. -6" B.O.F. -4' -0" W3W2 ***VERIFY ALL CHANGES IN WALL ELEVATION ON SITE. MAINTAIN 42" MINIMUM FROST PROTECTION AT ALL TIMES ***ALL FOUNDATION STEP- DOWNS TO BE DETERMINED ON SITE AS GRADE ALLOWS W1 DROP T.O.F. @ O.H.D.- VERIFY W/ GRADE 4' - 0 " 8" 4' - 0 " 8" 1' - 0 " 3' - 0 " 8" 8"8" 1' - 4"1' - 4" 1' - 4" CF16 1' - 4" 10 " W4 6" 3' - 6 " 8" 8" 1' - 4" NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL NOTE: STEP FOOTINGS DOWN AS GRADE REQUIRES. MAINTAIN MINIMUM FROST PROTECTION AT ALL TIMES. NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL PATIO ABOVE NOTE: CHANGES IN FOOTING AND FOUNDATION WALL ELEVATIONS ARE FOR DESIGN INTENT ONLY. ACTUAL ELEVATIONS SHALL BE VERIFIED W/FINAL GRADE DURING CONSTRUCTION. MAINTAIN 42" MINIMUM FROST PROTECTION ON ALL FOOTINGS. STEP DOWN FOOTING @ O.H.D. STOOP ABOVE 2' - 10"16' - 4"2' - 10" 16' - 0"14' - 4"11' - 8" 42' - 0" 46 ' - 8 " 22 ' - 0 " 2' - 0 " 2' - 0 " 72 ' - 8 " 7' - 8 " 11 ' - 4 " 38 ' - 8 " 15 ' - 0 " 72 ' - 8 " 22' - 0"20' - 0" 42' - 0" W4 W4 W4 W1 W2 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W4 W2 W2 29' - 0" 12 ' - 4 " 2' - 0 " 22' - 0"18' - 8" 2' - 4 " 8' - 4 " 45.00° 45.00° W3 4' - 0"4' - 4" TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL DOWEL STOOP SLAB TO FOUNDATION -VERIFY ALL CHANGES IN WALL ELEVATION ON SITE -MAINTAIN 42" MINIMUM FROST PROTECTION AT ALL TIMES POST P20 FOOTING F30 F24 CF16 1'-8'' 2'-6'' 2'-0'' 1'-4'' DIA 2'-6'' 2'-0'' CONT 4'-0'' 1'-0'' 1'-0'' 10'' (2) #4 CONT. #4 AT 12" O.C. E.W. #4 AT 12" O.C. E.W. (2) #4 CONT. -NOT ALL TYPES ARE USED F36 3'-0'' 3'-0'' 1'-0'' #4 AT 12" O.C. E.W. 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A100 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y ME N D O C I N O E S T A T E V 1 FO U N D A T I O N P L A N SCALE: 1/4" = 1'-0"2 FOOTING LEGEND SCALE: 1/4" = 1'-0"1 FOUNDATION PLAN FOUNDATION SCHEDULE Type Mark WALL FOOTING Width Unconnected Height Hotizontal Reinforcements Vertical Reinforcements Footing Width Footing Length Footing Depth Footing Reinforcing W1 8" 3' - 6" #4 @ TOP & BOT. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. W2 8" 4' - 0" #4 @ TOP & BOT. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. W3 8" 3' - 0" #4 @ TOP & BOT. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. W4 8" 3' - 6" #4 @ TOP & BOT. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. DW DW A2004 A200 A200 A200 2 3 1 3' - 0"16' - 0"3' - 0"11' - 0"9' - 0" 42' - 0" BEDROOM 1 BEDROOM 2 LIVING ROOM KITCHEN MASTER BEDROOM M. BATH PANTRY 3/ 0 X 6 / 8 BA R N D O O R LAUNDRY M. CLOSET BATH FOYER MUD COVERED PORCH OPTIONAL PATIO DINING R/ S 72 ' - 8 " 5' - 6"5' - 6"6' - 9"2' - 3" 2' - 0 " 13 ' - 0 " 38 ' - 8 " 11 ' - 4 " 7' - 8 " 72 ' - 8 " TWO CAR GARAGE CLOSET 2 3/0 x 6/8 2/ 1 0 x 6 / 8 W. C . 2/6 x 6/8 3/0 x 6/8 2/ 1 0 x 6 / 8 2/10 x 6/8 2/10 x 6/8 2/ 1 0 x 6 / 8 2/10 x 6/8 PCKT 3/ 0 x 6 / 8 72 8 2 S L D R 5359 FXD 2959 CSMT 29 2 9 T R S M 29 2 9 T R S M 8' - 0"8' - 0"6' - 9 1/2"7' - 6 1/2"6' - 8"5' - 0" 16' - 0"14' - 4"11' - 8" 5359 FXD2959 CSMT 2959 CSMT 29 5 9 C S M T 2959 CSMT 2959 CSMT 29 2 9 T R S M 2935 CSMT 2959 CSMT3- 16/0 X 8/0 O.H.D. W.C. O.H.C. O. H . C . O. H . C . 42' - 0" 2' - 6 " 5' - 2 " 4' - 9 " 6' - 7 " 15 ' - 9 " 6" 22 ' - 0 " 9' - 4 " 10 ' - 0 " 5' - 2 " 2' - 5 1 / 2 " 4' - 4 1 / 2 " 14 ' - 4 " 6" 6" 11 ' - 7 " 4' - 1 0 1 / 2 " 2' - 0 1 / 2 " 4' - 4 " 1' - 2 " 9' - 1 0 " 16 ' - 1 0 " 6" 10 ' - 1 0 " 6" 6/ 0 x 6 / 8 GIRDER TRUSS ABOVE 6"21' - 6"6"2' - 9 1/2"4' - 11"5' - 6" 5' - 9 1/2" 6" 6" 7' - 6"5' - 4"2' - 2"9' - 6"5' - 2 1/2"11' - 3 1/2"6" 6" 6' - 5 1/2"4' - 2"4' - 4 1/2" 5 1/2" 13' - 10 1/2" 6" 4' - 0 " 22 ' - 0 " 46 ' - 8 " 2' - 6 " 10 ' - 4 " 4' - 7 " 7' - 3 1 / 2 " 14 ' - 1 1 / 2 " 7' - 4 " 6" EQ EQ NICHE PLUMB WALL AS REQ'D VA U L T E D VA U L T E D GIRDER TRUSS ABOVE R/ S R/ S R/ S 32X60 TUB/SHWR 3/ 0 x 6 / 8 W 2/ 1 0 X 6 / 8 OP E N I N G RE F NOTE: DIMENSIONS AND ROOM SIZES ARE SHOWN FOR DESIGN PURPOSES ONLY. DUE TO CONSTRUCTION MEANS, METHODS AND TOLERANCES, ROOM SIZES ARE SUBECT TO CHANGE WITHOUT NOTICE. 6"10' - 0"6" 7' - 1 1 1 / 2 " 6' - 7 " 12 ' - 5 " 11 ' - 0 1 / 2 " 6" PEAK HT = 11'-2" RA N G E 2' - 0" HB HB OPTIONAL 12" TRAY 12" TRAY CLG. 12" TRAY CLG. COVERED PORCH FURN WH 22' - 0"20' - 0" OPTIONAL POCKET DOOR POCKET DOOR 2 A201 Sim 3 A201 Sim 29 1 7 F X D 29 1 7 F X D 8' - 6 " H . H . 8' - 6 " H . H . SHELVES O. H . C . GL A S S 5' - 1 0 " 1' - 0 " 1' - 0" 2/10 x 6/8 A101 3 6"7' - 6"2' - 6 1/2"4' - 11 1/2"9' - 6"5' - 2 1/2"11' - 3 1/2"6" 2/ 6 x 6 / 8 2959 CSMT2- 29 4 7 C S M T 2- 3/ 6 X 6 / 8 OP E N I N G SL O P E S L A B 6 " T O OV E R H E A D D O O R 0'-0" -0'-2" LO C K E R S 4' - 1 0 " 9' - 2 1 / 2 " 2/6 x 6/8 3/ 0 x 6 / 8 F.D. MECH ATTIC ACCESS ABOVE 135.00° CLOSET 1 5' - 8"1' - 8 3/4" 2/6 x 6/8 2' - 0 " 2' - 0"2' - 0" 2' - 0 " CL 1 CL 2 A101 4 8' - 1 1 " 14 ' - 0 " 29 5 9 C S M T 53 5 9 F X D 29 5 9 C S M T A2014 5 SI N K 6 A201 9 A2018 A201 MW H O O D MA K E U P A20110 LA V LA V . L A V . (2) 1 3/4x11 7/8 LVL HDR (2) 1 3/4x11 7/8 LVL HDR O. H . C . (2) 1 3/4x11 7/8 LVL HDR D 8' - 4 " 3' - 4" ROOF NOTES: 2'-0" EAVE OVERHANG*** 1' - 6" GABLE RAKES*** 10:12 SLOPE SIDE TO SIDE*** 6:12 SLOPE FRONT TO BACK*** ***UNLESS NOTED OTHERWISE PROVIDE RIDGE, HIP AND SOFFIT VENTING TO COMPLY W/ GOVERNING CODES SNOW AND ICE BARRIER ALONG ALL EAVES & RAKES 2' - 0" PAST OUTSIDE FACE OF FRAMING (TYPICAL @ ALL EXTERIOR EAVES) OUTSIDE FACE OF FRAMING BELOW 4 1 / 2 " / 1 2 " 4 1 / 2 " / 1 2 " 3" / 1 2 " 10" / 12"10" / 12" 1' - 6"1' - 6" 2' - 0 " 1' - 6" 2' - 0 " 2' - 0 " 2' - 0 " 1' - 6" 1' - 6" 2' - 0 " 1' - 6" 2' - 0 " 1' - 6" 2' - 0 " RIDGE SLOPE CHANGE VALLEY V A L L E Y RI D G E RI D G E RI D G E VALLEYV A L L E Y 10" / 12" 10" / 12" 8"10' - 8"8" 1' - 6 " DR O P Z O N E O. H . C . LO C K E R S RA N G E 3/ 0 X 6 / 8 BA R N D O O R PANTRY 2/ 1 0 x 6 / 8 2/4 x 6/8 3/ 0 x 6 / 8 MUD 3/0 x 6/8 A2017 SI M VA U L T E D VA U L T E D 11'-2" PEAK OP T . FP 29 5 9 C S M T 29 5 9 C S M T 2' - 1 0 1 / 2 " 2' - 1 0 1 / 2 " 5' - 4 " 2' - 1 0 1 / 2 " 2' - 1 0 1 / 2 " 2959 CSMT2- LIVING ROOM A2014 5 6A201 RE F RA N G E 12 ' - 1 " 3' - 3"3' - 0"3' - 3" 9' - 6" 1' - 1 " 1' - 0 " 2' - 1 " 1" 1" 2' - 0 " 3' - 0 " 1' - 6 " 1' - 6 " 1" 1" 8' - 4 " O.H.C. MW HO O D SI N K 2' - 6 " 2' - 6 " 1' - 6 " 1' - 3 " 1' - 3 " 1/ 2 " 3' - 0 " 1/ 2 " O.H.C. O.H.C. O. H . C . O . H . C . O . H . C . O. H . C . 3' - 4" 3/4"2' - 0"1' - 3 1/4" 1' - 6 " 1' - 6 " 3' - 0 " 1' - 10 1/2" 1' - 10 1/2" 1" 4' - 0 " 3' - 3 1 / 2 " 4' - 0 " 1" 11 ' - 5 1 / 2 " 1' - 10 1/2" 1' - 10 1/2" MA K E U P 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A101 19-137.2 3-18-2021 MS P L A N ML K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y ME N D O C I N O E S T A T E V 1 MA I N F L O O R P L A N SCALE: 1/4" = 1'-0"1 MAIN FLOOR PLAN SCALE: 1/4" = 1'-0"2 ROOF PLAN SCALE: 1/4" = 1'-0"3 MUD/PANTRY - OPTION B SCALE: 1/4" = 1'-0"4 FIREPLACE OPTION SCALE: 1/4" = 1'-0"5 MENDOCINO KITCHEN SCALE: 1/4" = 1'-0"6 MENDOCINO BATH SCALE: 1/4" = 1'-0"7 MENDOCINO MASTER BATH MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MAIN WIN. H.H. 6' -10" C1 M1 M2 S3 S1 2925 TRSM3- 2929 TRSM EQ EQ DORMER PLATE HT. 13'-4" B3 B2 T4 T5 L1 T1 T7 B3 T7 CONCRETE - SLOPE TO GRADE R1 T1 R1 T4 S3 F1 B3 M2 M1 T2 S1 T5 F1 R1 F1 S1 T1 T2 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE T5 C1 S1 F1 R1 F1 T1 S1 S3 B3 M1 M2 L1 T2T2 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE S1 R1 C1 T1 M1 T2 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE T1 R1 F1 FIREPLACE OPTION B WINDOW LOCATIONS 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A200 19-137.2 3-18-2021 MS P L A N ML K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y ME N D O C I N O E S T A T E V 1 EL E V A T I O N S SCALE: 1/4" = 1'-0"1 FRONT SCALE: 1/4" = 1'-0"2 BACK SCALE: 1/8" = 1'-0"3 LEFT SCALE: 1/8" = 1'-0"4 RIGHT Keynote Legend Key Value Keynote Text B2 COLUMN BRACKET - 1'-7" WIDE X 2-7" HIGH B3 DECORATIVE BRACKET - FYPON BKT25X27 C1 COLUMN WRAP - OR - TRIM OUT COLUMN F1 6" ALUMINUM FASCIA OR 6" ALUMINUM RAKE L1 EXTERIOR WALL LIGHT M1 MASONRY- CULTURED STONE M2 MASONRY- STONE CAP R1 LAMINATED ASPHALT ROOF SHINGLES S1 (LAP SIDING) HARDIE-PLANK SIDING-7" MAX EXPOSURE S3 (BOARD AND BATTEN SIDING) VERTICAL SIDING AND HARDIE TRIM T1 PAINTED HARDIE CORNER TRIM T2 4" PAINTED TRIM T4 6" OVER 8" PAINTED TRIM T5 7" OVER 12" PAINTED TRIM T7 4" TRIM AT WINDOWS ON FRONT ELEVATION ONLY 1X3 BATTENS ON SMOOTH PANEL SIDING SEE ROOF PLAN 36" PLASTIC ATTIC CHUTE SNOW AND ICE BARRIER EXTEND 24" PAST I.S. FACE OF EXTERIOR WALLS LAMINATED ASPHALT ROOF SHINGLES ON 15# ROOF FELT ON 1/2" O.S.B. SHEATHING MTL. DRIP 2X6 SUB-FASCIA 3/8" VENTED ALUMINUM SOFFIT & FASCIA ON 2X4 LOOKOUTS @ 24" O.C. 7" OVER 12" PAINTED TRIM SEE ELEVATIONS FOR SIDING MATERIAL WEATHER RESISTANT BARRIER OVER 1/2" O.S.B. SHEATHING ON 2X6 WALL STUDS @16" O.C. R21 INSULATION 1/2" GYP. BD. ON 6MIL POLY VAPOR BARRIER FLASHING (ALL HORIZ. JOINTS) 2X6 SILL PLATE "TRTD" ON CLOSED CELL FOAM SILL SEALER R49 BLOWN INSULATION 12 SE E R O O F PL A N MAIN FLOOR 12 " E N E R G Y H E E L M I N . T.O.F. 0'-0" 0'-4" FOUNDATION WALL-REFER TO PLAN TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL MAIN FLOOR PLT. HT. 9'-1 1/8" HOLD ALL TRIM AND SIDING MIN. 6" ABOVE GRADE 9' - 1 1 / 8 " CONTINUOUS BEAD OF SEALANT 4"4" 4' - 0 " LINE OF GRADE (VARIES) 2" 4" 2' - 0" HOLD ALL TRIM AND SIDING MIN. 6" MIN. ABOVE GRADE MAIN FLOOR 0'-0" TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL CONTINUOUS BEAD OF SEALANT 4"4" 2" 4" 2' - 0"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE GARAGE SLAB (SLOPE TO OVERHEAD DOOR) MAIN FLOOR 0'-0" TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL CONTINUOUS BEAD OF SEALANT 4"4" 2" 2' - 0"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE SLAB (SLOPE AWAY FROM HOUSE) MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 2' - 1 0 1 / 2 " 1 1 / 2 " 1' - 6 " 3' - 0 " 7' - 6 " 2' - 6"2' - 6 1/2"1' - 6"1' - 3"1' - 3"3' - 0 1/2" 12' - 1" 2' - 6"2' - 6"1' - 6"1' - 3"1' - 3" 1/2" 3' - 0"1/2" 12' - 1" 1' - 6 " 6' - 0 " 7' - 6 " REF. MW HOOD RANGE MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 3' - 3"3' - 0"3' - 3" 9' - 6" 2' - 1 0 1 / 2 " 1 1 / 2 " 1' - 6 " 3' - 0 " 7' - 6 " 3' - 3"3' - 0"3' - 3" 9' - 6" MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 1"2' - 0"3' - 0"1' - 6"1' - 6"1" 8' - 2" 2' - 1 0 1 / 2 " 1 1 / 2 " 3' - 0 " DW MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 2' - 1 0 1 / 2 " 1 1 / 2 " 1' - 6 " 3' - 0 " 7' - 6 " REF. MW HOOD RANGE PANTRY 1' - 9"2' - 6 1/2"1' - 6" 5' - 9 1/2" 6' - 0 " 1' - 6 " 7' - 6 " 1' - 9"2' - 6"1' - 6"3' - 0" 8' - 9" MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 1"4' - 0"3' - 3 1/2"4' - 0"1" 11' - 5 1/2" 2' - 1 0 1 / 2 " 1 1 / 2 " 3' - 0 " MAKEUP 2' - 4 1 / 2 " 1 1 / 2 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 3' - 0" 2' - 1 0 1 / 2 " 1 1 / 2 " 3' - 0 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 4' - 6 " 3' - 0 " 7' - 6 " 2' - 6"2' - 6" 5' - 0" W/D 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A201 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y ME N D O C I N O E S T A T E V 1 DE T A I L S WINDOW SCHEDULE From Room: Name Type Comments BATH 2935 CSMT E3 DINING 2959 CSMT E DINING 5359 FXD DINING 2959 CSMT E BEDROOM 1 2959 CSMT E BEDROOM 1 2959 CSMT E BEDROOM 1 2959 CSMT E 2925 TRSM GABLE 2925 TRSM GABLE 2925 TRSM GABLE 2929 TRSM GABLE MASTER BEDROOM 2959 CSMT E MASTER BEDROOM 5359 FXD MASTER BEDROOM 2959 CSMT E LAUNDRY 2929 TRSM MASTER BEDROOM 2929 TRSM MASTER BEDROOM 2959 CSMT E MASTER BEDROOM 2929 TRSM DINING 2959 CSMT E M. BATH 2917 FXD 2917 FXD LIVING ROOM 2959 CSMT E LIVING ROOM 2959 CSMT E 2959 CSMT E BEDROOM 2 2947 CSMT E BEDROOM 2 2947 CSMT E LIVING ROOM 2959 CSMT E LIVING ROOM 2959 CSMT E 5359 FXD LIVING ROOM 2959 CSMT E Grand total: 30 NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL SCHEDULES PRIOR TO BIDDING AND CONSTRUCTION. VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION. DOOR SCHEDULE Level Type To Room: Name Door CommentsWidth Height Material Finish MAIN FLOOR 3/0 x 6/8 Sliding Door 3' - 0" 6' - 8" MAIN FLOOR 2/4 x 6/8 2' - 4" 6' - 8" MAIN FLOOR 2/10 x 6/8 BATH 2' - 10" 6' - 8" MAIN FLOOR 2/10 x 6/8 BEDROOM 1 2' - 10" 6' - 8" MAIN FLOOR 3/0 x 6/8 BEDROOM 2 3' - 0" 6' - 8" MAIN FLOOR 2/6 x 6/8 CLOSET 1 2' - 6" 6' - 8" MAIN FLOOR 2/6 x 6/8 CLOSET 2 2' - 6" 6' - 8" MAIN FLOOR 7282 SLDR DINING 6' - 0" 6' - 10" MAIN FLOOR 3/0 x 6/8 FOYER 3' - 0" 6' - 8" MAIN FLOOR 6/0 x 6/8 FOYER 6' - 0" 6' - 8" MAIN FLOOR 2/10 x 6/8 LAUNDRY 2' - 10" 6' - 8" MAIN FLOOR 2/10 x 6/8 PCKT 2 M. BATH 2' - 10" 6' - 8" MAIN FLOOR 2/10 x 6/8 M. BATH 2' - 10" 6' - 8" MAIN FLOOR 2/10 x 6/8 M. BATH 2' - 10" 6' - 8" MAIN FLOOR 2/10 x 6/8 M. CLOSET 2' - 10" 6' - 8" MAIN FLOOR 3/0 x 6/8 MASTER BEDROOM 3' - 0" 6' - 8" MAIN FLOOR 3/0 x 6/8 MECH 3' - 0" 6' - 8" MAIN FLOOR 3/0 x 6/8 MUD 3' - 0" 6' - 8" MAIN FLOOR 34" x 80" MUD 0" 0" MAIN FLOOR 2/6 x 6/8 MUD 2' - 6" 6' - 8" MAIN FLOOR 2/6 x 6/8 PANTRY 2' - 6" 6' - 8" T.O.F. 16'-0" x 8'-0" TWO CAR GARAGE 16' - 0" 8' - 0" NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL SCHEDULES PRIOR TO BIDDING AND CONSTRUCTION. VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION. ROOM FINISH SCHEDULE- OVERALL ROOM NO ROOM NAME AREA FLOOR BASE WALLS CEILING NOTESN E S W FINISH HEIGHT 35 BEDROOM 1 110 SF CARPET 36 BEDROOM 2 118 SF CARPET 37 LIVING ROOM 195 SF LVP 38 KITCHEN 277 SF LVP 39 MASTER BEDROOM 215 SF CARPET 40 M. BATH 136 SF LVT 41 PANTRY 23 SF LVP 42 LAUNDRY 67 SF LVP 43 M. CLOSET 72 SF CARPET 45 BATH 50 SF LVT 46 FOYER 133 SF LVP 47 MUD 89 SF LVP 48 DINING 158 SF LVP 49 TWO CAR GARAGE 463 SF CONCRETE 50 CLOSET 2 20 SF CARPET 51 MECH 71 SF CONCRETE 52 CLOSET 1 21 SF CARPET 53 CL 1 18 SF LVP 54 CL 2 10 SF LVP NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL SCHEDULES PRIOR TO BIDDING AND CONSTRUCTION. VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION. SCALE: 1/2" = 1'-0"1 TYPICAL SLAB ON GRADE WALL SECTION SCALE: 1" = 1'-0"2 TYP. ZERO ENTRY DETAIL - GARAGE SCALE: 1" = 1'-0"3 TYP. ZERO ENTRY DETAIL - STOOP SCALE: 1/4" = 1'-0"4 KITCHEN ELEVATION 1 SCALE: 1/4" = 1'-0"5 KITCHEN ELEVATION 2 SCALE: 1/4" = 1'-0"6 KITCHEN ISLAND ELEVATION SCALE: 1/4" = 1'-0"7 KITCHEN ELEVATION - OPTION B SCALE: 1/4" = 1'-0"8 MASTER BATH ELEVATION SCALE: 1/4" = 1'-0"9 BATH ELEVATION SCALE: 1/4" = 1'-0"10 LAUNDRY ELEVATION SCALE: 1" = 1'-0"11 TERMITE GUARD GENERAL NOTES B. Submit floor truss layouts showing beam locations, joist layout, locations of continuous duct chases, and maximum duct size in each chase. Allow designer five days for complete review. lumber package. Allow designer five days for complete review. manufacturer for review prior to ordering roof trusses and/or roof A. Submit roof truss and/or rafter layout plan as completed by the 12. SUBMITTALS 8. DOORS AND WINDOWS A. Exterior doors shall be selected by the Owner. B. House-to-garage doors shall be fire rated doors approved by governing codes. Face design to be selected by the Owner. C. Interior doors shall be selected by the Owner. D. Exterior windows by Pella Corp as selected by owner. E. Glazing in all doors and windows shall comply with governing codes. F. Install egress window units in accordance with governing codes. G. Door and window sizes indicated or drawings are as follows: "3/0x6/8" represents a door or window 3'-0" wide x 6'-8" high. Jamb depth to be coordinated by the Contractor. H. Finish hardware shall be selected by the owner. Install hardware in accordance with governing codes. 9. FINISHES A. Gypsum wallboard, unless noted otherwise, shall be provided as follows: 1. Exterior walls: One layer 1/2" regular wallboard to interior face. 2. Interior walls: One layer 1/2" regular wallboard each face. 3. Ceiling: One layer 5/8" regular wallboard. 4. Garage/House common wall: One layer 5/8" type "X" wallboard each face. 5. Baths: Water resistant wallboard at all walls and ceilings surrounding tubs and showers and as required by governing codes. Provide cement board as substrate for ceramic tile. B. Provide metal corner bead and trim at all locations recommended by the gypsum wallboard manufacturer. C. Tape, float, and sand joints and fasteners of gypsum wallboard with three coats of joint compound as required to obtain a uniformly smooth surface. D. Finishes shall be selected by the Owner. 10. PLUMBING, MECHANICAL, AND ELECTRICAL A. Plumbing, mechanical, and electrical information and layouts shown on the Drawings is schematic in design, and shall be reviewed by sub-contractors, suppliers, and building officials for compliance with governing codes and good common construction practices. The Architect shall be notified by the Contractor of any discrepancies prior to construction. B. Plumbing, mechanical, and electrical equipment shall be selected by the Owner. C. Design and installation of plumbing, mechanical, and electrical equipment shall be the responsibility of the appropriate licensed contractors and sub- contractors. Design shall be submitted for owner's review prior to ordering D. Service panels shall be selected by the electrical sub-contractor. E. All HVAC equipment shall be individually switched. F. All outdoor, bath, and garage and spa wall receptacles shall be provided with ground fault circuit protection in accordance with governing codes. G. Dryer vents shall be extended to the exterior. H. Provide plumbing vents in accordance with governing codes. Minimize number and locate for minimal visual impact. I. Install type and number of smoke detectors in accordance with governing codes & UL217. J. Connect water, gas, and electric services in accordance with governing codes. 11. MISCELLANEOUS and installation of equipment. exterior walls install plates over foam sill sealer. C. Unless noted otherwise, all slabs on grade shall be 4" thick, reinforced with 6x6 W1.4xW1.4 W.W.M., and placed over 4" minimum compacted sand or gravel fill. Interior slabs shall be placed over 6 mil. Stabilized polyethylene vapor barrier. Coordinate with radon removal procedures. D. Footing sizes shown are typical only for stated soil pressure and consistent compaction. Contractor shall be responsible for footings complying with A. Adhered masonry flashing must be installed at wall penetrations and terminations integrated with the WRB properly (when used), and installed in accordance with the to ensure a consistent overall project color on the wall. C. Install in accordance with manufacturer's installation instructions. Visit this page for http://ncmabr.org/pdfs/masterlibrary/MVMA%20Installation%20Guide%204th%20Edition%20web.pdf Consult manufacturer for proper installation instructions. modified mortar meeting ANSI A118.4 OR ANSI 118.15. F. Touch-up, repair or replace damaged stone before completion of project. A. All structural steel shall comply with appropriate ASTM Specifications as follows: ASTM A36, ASTM A53, ASTM A501, ASTM A307, and ASTM A. Lumber shall, in addition to complying with governing codes, comply with: 1. "Product Use Manual" of the Western Wood Products Association for selection and use of products included in that manual. 2. "Plywood Specification and Grade Guide" of the American Plywood 3. "Standard Specifications for Grades of California Redwood Lumber" of 4. American Wood Preservers Association standards and recommendations for fire-retardate and preservative pressure treated lumber and plywood. 5. Western Red Cedar Lumber Association standards and recommendations the Redwood Inspection Bureau for Redwood. for cedar. Association. D. Application details and mortar recommendations may vary depending on the stone style. E. All dry-stacked and large format standard stones must be applied using a polymer - 5. METALS A325. 6. WOOD AND PLASTICS the design requirements of specific soil conditions. of the stone veneer. Assure that all flashing and kickouts are corrosion resistant, local building code requirements. B. Product should be pulled from a variety of boxes and blended on site during intalllation installation instructions: 4. MASONRY Install skylights according to the manufactures' recommendations. I. Install water and ice barrier (Bituthene or equal) over roof sheathing at all eaves and valleys. water & ice barrier to extend 24" past outside face of L. Provide 2" nominal pressure treated lumber over foam sill sealer beneath full bearing of wood beams bearing on concrete or 7. THERMAL AND MOISTURE PROTECTION A. Provide thermal building insulation at assemblies adjacent to exterior or unheated spaces meeting the requirements of governing codes and, unless noted otherwise, meeting the following minimum requirements: 1. Foundations: 1 1/2"extruded polystyrene (R-10) 2. Walls: glass fiber batt (R-20) U.N.O. 3. Floors: glass fiber batt (R-30) -for floors over unconditioned space or exterior 4. Ceilings: glass fiber batt (R-49) 5. Install continuous blankets without holes for electrical boxes, lighting fixtures, or heating ductwork. B. Install 6 mil. stabilized polyethylene vapor barrier against interior face of all C. Waterproof foundation walls at excavated areas from footing to finished grade with two coats of asphalt based waterproofing compound for full basements. D. Roofing shall be 240 lb. (minimum) composition shingles installed over 15 lb. roof felt on roof sheathing. Minimum slope, fasteners, under layment, and exposure according to manufacturers' recommendations. E. Provide flashing and sheet metal required to prevent penetration of water through the exterior shell of the building. In addition to complying with governing codes, comply with pertinent recommendations contained in the current edition of "Architectural Sheet Metal Manual" published by SMCNA. All iron sheet metal flashing shall be hot-dipped galvanized complying with F. Provide gutters and downspouts to provide positive roof and site drainage. G. Provide attic and roof ventilation as required by governing codes and as shown on the Drawings. Provide appropriate soffit and roof vents. H. Skylights shall be selected by the Contractor and approved by the owner. ASTM A93. thermal insulation. masonry. 1. Before final Drawings and Specifications are issued for construction, they shall be submitted to all governing building agencies to insure their compliance with all applicable local and national codes. If code discrepancies in Drawings and/or Specifications appear, the Architect shall be notified of such discrepancies in writing by the Contractor or building official, and allowed to alter the drawings and specifications so as to comply with governing codes before construction begins. 2. Upon written receipt of approval from the governing official, approved final Drawings and Specifications shall be submitted to the Contractor by 3. If code discrepancies are discovered during the construction process, the Architect shall be notified and allowed ample time to remedy said 4. All work performed shall comply with all applicable local, state and national building codes, ordinances and regulations, and all other B. All contractors, suppliers, and fabricators shall be responsible for the content of the Drawings, and for the supply and design of appropriate C. All manufactured articles, materials, and equipment shall be handled, applied, installed, erected, used, cleaned, and conditioned in strict accordance with the D. All alternates are at the option of the Owner and shall be at the Owner's request, constructed in addition to or in lieu of the typical construction, as dead load 15psf (10 psf top, 5psf bottom) dead load 15psf (10 psf top, 5psf bottom) 5. Prior to start of construction, verify design loads with governing codes and site conditions. Check with local building agencies for wind, seismic, snow and other special loading conditions. If discrepancies are discovered, Architect shall be notified according to Section 1.A.1 above. A. Perform excavation, according to good common construction practices, to the lines, grades, and elevations indicated on the Drawings. B. Provide consistent compaction of the top 8" of sub-grade, fill, and backfill material beneath structures, walks, and pavements to meet the stated soil C. Provide soil poisoning to control termites as required by governing codes. D. Provide and install ventilation for Radon Gas as required by local building A. Provide concrete complying with ASTM C94. Unless otherwise noted, concrete shall have the following 28 day compressive strengths as minimums: 2. Concrete floor slabs, walks, drives, and patios: 3,500psi 3. Provide construction joints so panel size does not exceed 400sf. B. Provide reinforcement of the size and spacing indicated on Drawings. Reinforcing shall comply with the following minimums: live load 60psf (maximum) live load 40psf (maximum) live load 30psf (maximum) agencies and governing codes. 1. Concrete footings and foundations: 3,000psi 1. Bars: ASTM A615, grade 40, deformed bars. 2. Welded Wire Fabric: ASTM A185. 3. CONCRETE 2. SITE WORK pressure. materials and work performance. manufacturers' requirements. indicated on the Drawings. 3. Balconies and Decks: 4. Soil Pressure: 1500 psf (minimum) 2. Floor: 1. Roof: E. Design Loads: dead load 10psf 1. GENERAL REQUIREMENTS authorities having jurisdiction. discrepancies. the Architect. A. Codes: drawings to designer for review prior to construction. spacing of all trusses. Contractor to submit truss drawings and/or roof framing b. Install joist and beam hangers capable of supporting the maximum allowable load of joist or beam being supported. C. Provide "Micro-Lam" glue laminated veneer lumber beams (manufactured by Truss Joist Corporation) or equal, of the dimensions and number indicated on the drawings. Provide exterior grade Micro Lams for deck framing and other in strict accordance with manufacturers' recommendations. a. Modulus of elasticity: 2,000,000 psi b. Flexural (12" depth): 2,900 psi c. Horizontal shear: 285 psi D. Provide wood trusses able to sustain the stated loads for the spans, profiles, and arrangement shown on the Drawings. Truss layout is schematic only. Truss manufacturer and/or engineer shall be responsible for the design and E. All roof trusses shall be installed with metal truss seats as specified by the F. Unless noted otherwise, provide: 1. Double header joists and trimmers at all floor openings. 2. Double joists under all partitions parallel to joists. 3. Double 2x12 headers with 1/2 OSB between at all door and window openings in 2x4 walls. Triple 2x10 headers with 1/2" OSB between at all door and window openings at 2x6 walls. 4. For solid sawn joists, provide one row of 1x3 cross -bridging or metal bridging G. Stud spacing at all exterior and bearing walls shall be 16" o.c. minimum. H. Stud walls shall not exceed the following heights without continuous lateral support perpendicular to the plane of the wall at the stated height or less. Studs shall be continuous between points of lateral support. I. Unless noted otherwise, rafters, ceiling joists, collar ties, and purlins shall be sized and spaced in accordance with FHA requirements or governing codes, J. Stair construction shall consist of (3)2x12 stringers, 5/4" or 2x thick tread and 3/4" thick risers or, shall be fabricated by component manufacturer. K. All wood plates bearing on concrete or masonry shall be pressure treated. At b. 2x6: 12'-0' 2. Non-bearing walls: a. 2x4: 14'-0" b. 2x6: 20'-0" whichever is more restrictive. 1. Bearing walls: a. 2x4: 10'-0" for each 8'-0" of joist span. d. Bearing: 550 psi truss manufacturer. 1. Allowable stresses: B. Provide lumber and materials meeting or exceeding the following standards of a. Studs: Douglas Fir-Larch, Stud Grade -or as approved by building code. b. Headers and Beams: Douglas Fir -Larch, No. 2 and better -or as appoved by building code. 2. All headers and beams shall be free from splits, checks, and shakes. a. Roof: 1/2" OSB APA RATED SHEATHING, EXP 1. b. Walls: 1/2" OR 7/16" OSB APA RATED SHEATHING, EXP 1. c. Floor: 23/32" plywood APA RATED SHEATHING, EXP 1. d. Proper oriented strand board may be substituted for plywood. steel at exterior locations. a. Steel items: Comply with ASTM A36; use galvanized 3. Sheathing: (with clips) (glue and nail) 4. Rough Hardware: 1. Framing Members: quality: Contractor to submit steel shop drawings to designer or a licensed structural Construction and shall be detailed by a qualified structural steel detailer. B. All steel connections shall be designed according to AISC Manual of Steel engineer prior to steel erection. C. Architect will not be responsible for any errors in the roof and/or floor framing without the opportunity to review the roof and/or floor framing layouts. Framing layouts, member sizes, and floor/roof penetrations indicated on the drawings are for design intent only. Final layouts shall be the responsibility of builder. exterior applications. Unless noted otherwise, fasten multiple beams together exterior wall below. And as shown on the roof plan. A. This set of construction drawings is intended for design intent only. Although many jurisdictions will accept these drawings as sufficient for a construction permit, these drawings are not intended, and should not be construed, as a complete set of construction drawings. These drawings will have to be adapted to meet local zoning and/or site conditions and additional detailing will need to be completed on site by the builder. B. Install prefabricated fireplace units as shown on Drawings. 1. Fireplace units shall be "Heat-N-Glo" or as approved by Owner. 2. Contractor shall be responsible for proper installation as recommended by the manufacturer and as required by governing codes, including mantel and hearth design and location. C. Room sizes shown on the plans indicate room dimensions prior to installation of gypsum wall board. Gypsum wall board thickness must be subtracted from room sizes indicated for actual room dimensions and are subject to change. 2. Use exterior grade Micro-Lam in all areas subject to moisture. 3. Hearth shall be of non-combustible material. EARTH RIGID INSULATION CONCRETE BLOCK CONCRETE BRICK PLYWOOD STEEL OR STEEL STUD WALL BATT INSULATION GYPSUM BOARD GRAVEL WOOD OR WOOD STUD WALL SOUND INSULATION IN WALL MIN. (3) 2X SOLID BLOCKING BEARING WALL MATERIALS ELEVATION DRAWING NUMBER WALL TYPE SHEET NUMBER SHEET NUMBER SECTION DRAWING NUMBER DETAIL DRAWING NUMBER SHEET NUMBER POINT LOAD FROM ABOVE ELEVATION HEIGHT ELEVATION TYPE W2 SYMBOLS VINTAGE COOP PLAN INFORMATION PLAN OPTION: FOUNDATION: ROOF TRUSS: MENDOCINO ESTATE SLAB ON GRADE UPPER FLOOR BONUS ROOM FULL BASEMENT STANDARD ROOF TRUSSES 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : IS S U E D F O R : 11 - 2 3 - 2 0 FO R C O N S T R U C T I O N 11 - 3 0 - 2 0 RE V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 RE V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 OW N E R R E Q U E S T E D C H A N G E S A0 19-137.2 3-18-2021 MS P L A N LR KC VI N T A G E E S T A T E S - N O R T H L I B E R T Y ME N D O C I N O E S T A T E V 2 TI T L E S H E E T SHEET LIST Sheet Number Sheet Name A0 TITLE SHEET A100 FOUNDATION PLAN A101 MAIN FLOOR PLAN A200 ELEVATIONS A201 DETAILS AREA SCHEDULE Level Name Area MAIN FLOOR MAIN FLOOR 2010 SF MAIN FLOOR GARAGE 547 SF Grand total: 2 2557 SF NOTE: THIS DRAWING IS AN ARTISTIC INTERPRETATION OF THE GENERAL APPEARANCE OF THE DESIGN. IT IS NOT INTENDED TO BE AN EXACT RENDITION. MAIN FLOOR 0" T.O.F. -6" B.O.F. -4' -0" W3W2 ***VERIFY ALL CHANGES IN WALL ELEVATION ON SITE. MAINTAIN 42" MINIMUM FROST PROTECTION AT ALL TIMES ***ALL FOUNDATION STEP- DOWNS TO BE DETERMINED ON SITE AS GRADE ALLOWS W1 DROP T.O.F. @ O.H.D.- VERIFY W/ GRADE 4' - 0 " 8" 4' - 0 " 8" 1' - 0 " 3' - 0 " 8" 8"8" 1' - 4"1' - 4" 1' - 4" CF16 1' - 4" 10 " W4 6" 3' - 6 " 8" 8" 1' - 4" NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL NOTE: STEP FOOTINGS DOWN AS GRADE REQUIRES. MAINTAIN MINIMUM FROST PROTECTION AT ALL TIMES. NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL PATIO ABOVE NOTE: CHANGES IN FOOTING AND FOUNDATION WALL ELEVATIONS ARE FOR DESIGN INTENT ONLY. ACTUAL ELEVATIONS SHALL BE VERIFIED W/FINAL GRADE DURING CONSTRUCTION. MAINTAIN 42" MINIMUM FROST PROTECTION ON ALL FOOTINGS. STEP DOWN FOOTING @ O.H.D. STOOP ABOVE 2' - 10"16' - 4"2' - 10" 16' - 0"14' - 4"11' - 8" 42' - 0" 46 ' - 8 " 24 ' - 0 " 2' - 0 " 2' - 0 " 74 ' - 8 " 7' - 8 " 11 ' - 4 " 38 ' - 8 " 17 ' - 0 " 74 ' - 8 " 22' - 0"10' - 4"9' - 8" 42' - 0" W4 W4 W4 W4 W1 W2 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W4 W2 W2 29' - 0" 14 ' - 4 " 2' - 0 " 22' - 0"18' - 8" 2' - 4 " 8' - 4 " 45.00° 45.00° W3 4' - 0"4' - 4" TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL DOWEL STOOP SLAB TO FOUNDATION -VERIFY ALL CHANGES IN WALL ELEVATION ON SITE -MAINTAIN 42" MINIMUM FROST PROTECTION AT ALL TIMES POST P20 FOOTING F30 F24 CF16 1'-8'' 2'-6'' 2'-0'' 1'-4'' DIA 2'-6'' 2'-0'' CONT 4'-0'' 1'-0'' 1'-0'' 10'' (2) #4 CONT. #4 AT 12" O.C. E.W. #4 AT 12" O.C. E.W. (2) #4 CONT. -NOT ALL TYPES ARE USED F36 3'-0'' 3'-0'' 1'-0'' #4 AT 12" O.C. E.W. 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A100 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y ME N D O C I N O E S T A T E V 2 FO U N D A T I O N P L A N SCALE: 1/4" = 1'-0"2 FOOTING LEGEND SCALE: 1/4" = 1'-0"1 FOUNDATION PLAN FOUNDATION SCHEDULE Type Mark WALL FOOTING Width Unconnected Height Hotizontal Reinforcements Vertical Reinforcements Footing Width Footing Length Footing Depth Footing Reinforcing W1 8" 3' - 6" #4 @ TOP & BOT. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. W2 8" 4' - 0" #4 @ TOP & BOT. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. W3 8" 3' - 0" #4 @ TOP & BOT. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. W4 8" 3' - 6" #4 @ TOP & BOT. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. 7 " DW A2004 A200 A200 A200 2 3 1 3' - 0"16' - 0"3' - 0"11' - 0"9' - 0" 42' - 0" BEDROOM 1 BEDROOM 2 LIVING ROOM KITCHEN MASTER BEDROOM M. BATH PANTRY 3/ 0 X 6 / 8 BA R N D O O R LAUNDRY M. CLOSET BATH FOYER MUD COVERED PORCH OPTIONAL PATIO DINING R/ S 74 ' - 8 " 5' - 6"5' - 6"6' - 9"2' - 3" 2' - 0 " 15 ' - 0 " 38 ' - 8 " 11 ' - 4 " 7' - 8 " 74 ' - 8 " TWO CAR GARAGE CLOSET 2 3/0 x 6/8 2/10 x 6/8 W. C . 2/6 x 6/8 3/0 x 6/8 2/ 1 0 x 6 / 8 2/10 x 6/8 2/10 x 6/8 2/ 1 0 x 6 / 8 2/10 x 6/8 PCKT 3/ 0 x 6 / 8 72 8 2 S L D R 5359 FXD 2959 CSMT 29 2 9 T R S M 29 2 9 T R S M 8' - 0"8' - 0"6' - 9 1/2"7' - 6 1/2"6' - 8"5' - 0" 16' - 0"14' - 4"11' - 8" 5359 FXD2959 CSMT 2959 CSMT 29 5 9 C S M T 2959 CSMT 2959 CSMT 29 2 9 T R S M 2935 CSMT 2959 CSMT3- 16/0 X 8/0 O.H.D. W.C. O.H.C. O. H . C . O. H . C . 42' - 0" 2' - 6 " 5' - 2 " 4' - 9 " 6' - 7 " 15 ' - 9 " 6" 24 ' - 0 " 9' - 4 " 10 ' - 0 " 5' - 2 " 2' - 5 1 / 2 " 4' - 4 1 / 2 " 14 ' - 4 " 6" 6" 13 ' - 7 " 4' - 1 0 1 / 2 " 2' - 0 1 / 2 " 4' - 4 " 1' - 2 " 9' - 1 0 " 16 ' - 1 0 " 6" 10 ' - 1 0 " 6" 6/ 0 x 6 / 8 GIRDER TRUSS ABOVE 6"21' - 6"6"2' - 9 1/2"4' - 11"5' - 6" 5' - 9 1/2" 6" 6" 7' - 6"5' - 4"2' - 2"9' - 6"5' - 2 1/2"11' - 3 1/2"6" 6" 6' - 5 1/2"4' - 2"4' - 4 1/2" 5 1/2" 13' - 10 1/2" 6" 4' - 0 " 24 ' - 0 " 46 ' - 8 " 2' - 6 " 10 ' - 4 " 4' - 7 " 7' - 3 1 / 2 " 14 ' - 1 1 / 2 " 7' - 4 " 6" EQ EQ NICHE PLUMB WALL AS REQ'D VA U L T E D VA U L T E D GIRDER TRUSS ABOVE R/ S R/ S R/ S 32X60 TUB/SHWR 3/ 0 x 6 / 8 DW W D 2/ 1 0 X 6 / 8 OP E N I N G RE F NOTE: DIMENSIONS AND ROOM SIZES ARE SHOWN FOR DESIGN PURPOSES ONLY. DUE TO CONSTRUCTION MEANS, METHODS AND TOLERANCES, ROOM SIZES ARE SUBECT TO CHANGE WITHOUT NOTICE. 6"10' - 0"6" 7' - 1 1 1 / 2 " 19 ' - 0 " 11 ' - 0 1 / 2 " 6" PEAK HT = 11'-2" RA N G E 2' - 0" HB HB OPTIONAL 12" TRAY 12" TRAY CLG. 12" TRAY CLG. COVERED PORCH FURN WH 22' - 0"20' - 0" OPTIONAL POCKET DOOR POCKET DOOR 2 A201 Sim 3 A201 Sim 29 1 7 F X D 29 1 7 F X D 8' - 6 " H . H . 8' - 6 " H . H . SHELVES O. H . C . GL A S S 5' - 1 0 " 1' - 0 " 1' - 0" 2/10 x 6/8 A101 3 6"7' - 6"2' - 6 1/2"4' - 11 1/2"9' - 6"5' - 2 1/2"11' - 3 1/2"6" 2/ 6 x 6 / 8 2959 CSMT2- 29 4 7 C S M T 2- 3/ 6 X 6 / 8 OP E N I N G SL O P E S L A B 6 " T O OV E R H E A D D O O R 0'-0" -0'-2" LO C K E R S 4' - 1 0 " 9' - 2 1 / 2 " 2/6 x 6/8 3/ 0 x 6 / 8 F.D. MECH ATTIC ACCESS ABOVE 135.00° CLOSET 1 5' - 8"1' - 8 3/4" 2/6 x 6/8 2' - 0 " 2' - 0"2' - 0" 2' - 0 " CL 2 CL 1 4" 29 5 9 C S M T 53 5 9 F X D 29 5 9 C S M T 8' - 1 1 " 14 ' - 0 " A101 4 A2018 A201 9 A2016 4 5A201 (2) 1 3/4x11 7/8 LVL HDR (2) 1 3/4x11 7/8 LVL HDR (2) 1 3/4x11 7/8 LVL HDR MA K E U P LA V LA V . L A V . O. H . C . A20111 A101 6 3' - 4" 8' - 4 " ROOF NOTES: 2'-0" EAVE OVERHANG*** 1' - 6" GABLE RAKES*** 10:12 SLOPE SIDE TO SIDE*** 6:12 SLOPE FRONT TO BACK*** ***UNLESS NOTED OTHERWISE PROVIDE RIDGE, HIP AND SOFFIT VENTING TO COMPLY W/ GOVERNING CODES SNOW AND ICE BARRIER ALONG ALL EAVES & RAKES 2' - 0" PAST OUTSIDE FACE OF FRAMING (TYPICAL @ ALL EXTERIOR EAVES) OUTSIDE FACE OF FRAMING BELOW 4 1 / 2 " / 1 2 " 4 1 / 2 " / 1 2 " 3" / 1 2 " 10" / 12"10" / 12" 1' - 6"1' - 6" 2' - 0 " 1' - 6" 2' - 0 " 2' - 0 " 2' - 0 " 2' - 0" 1' - 6" 2' - 0 " 1' - 6" 2' - 0 " 1' - 6" 2' - 0 " RIDGE SLOPE CHANGE VALLEY V A L L E Y RI D G E RI D G E RI D G E VALLEYV A L L E Y 10" / 12" 10" / 12" 10" / 12"10" / 12" 8"10' - 8"8" 1' - 6 " DR O P Z O N E O. H . C . LO C K E R S GL A S S RA N G E 3/ 0 X 6 / 8 BA R N D O O R PANTRY 2/ 1 0 x 6 / 8 2/4 x 6/8 3/ 0 x 6 / 8 MUD 3/0 x 6/8 A2017 SI M VA U L T E D VA U L T E D 11'-2" PEAK OP T . FP 29 5 9 C S M T 29 5 9 C S M T 2' - 1 0 1 / 2 " 2' - 1 0 1 / 2 " 5' - 4 " 2' - 1 0 1 / 2 " 2' - 1 0 1 / 2 " 2959 CSMT2- LIVING ROOM A2016 4 5A201 RE F RA N G E 3' - 3"3' - 0"3' - 3" 9' - 6" 1' - 1 " 1' - 0 " 2' - 1 " 8' - 4 " O.H.C. MW HO O D SI N K 2' - 6 " 2' - 6 " 1' - 6 " 1' - 3 " 1' - 3 " 1/ 2 " 3' - 0 " 1/ 2 " O.H.C. O.H.C. O. H . C . O . H . C . O . H . C . O. H . C . 1" 1" 2' - 0 " 3' - 0 " 1' - 6 " 1' - 6 " 1" 1" 3/4"2' - 0"1' - 3 1/4" 12 ' - 1 " KITCHEN 3' - 4" 1' - 6 " 1' - 6 " 3' - 0 " 1' - 10 1/2" 1' - 10 1/2" 1" 7' - 3 1 / 2 " 0" 4' - 0 " 1" 11 ' - 5 1 / 2 " MA K E U P 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A101 19-137.2 3-18-2021 MS P L A N ML K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y ME N D O C I N O E S T A T E V 2 MA I N F L O O R P L A N SCALE: 1/4" = 1'-0"1 MAIN FLOOR PLAN SCALE: 1/4" = 1'-0"2 ROOF PLAN SCALE: 1/4" = 1'-0"3 MUD/PANTRY - OPTION B SCALE: 1/4" = 1'-0"4 FIREPLACE OPTION SCALE: 1/4" = 1'-0"5 MENDOCINO KITCHEN SCALE: 1/4" = 1'-0"6 MENDOCINO BATH SCALE: 1/4" = 1'-0"7 MENDOCINO MASTER BATH MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MAIN WIN. H.H. 6' -10" C1 M1 M2 S3 S1 2925 TRSM3- 2929 TRSM EQ EQ DORMER PLATE HT. 13'-4" B3 B2 T4 T5 L1 T1 T7 B3 T7 CONCRETE - SLOPE TO GRADE R1 T1 R1 T4 S3 F1 B3 M2 M1 T2 S1 T5 F1 R1 F1 S1 T1 T2 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE T5 C1 S1 F1 R1 F1 T1 S1 S3 B3 M1 M2 L1 T2T2 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE S1 R1 C1 T1 M1 T2 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE T1 R1 F1 FIREPLACE OPTION B WINDOW LOCATIONS 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A200 19-137.2 3-18-2021 MS P L A N ML K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y ME N D O C I N O E S T A T E V 2 EL E V A T I O N S SCALE: 1/4" = 1'-0"1 FRONT SCALE: 1/4" = 1'-0"2 BACK SCALE: 1/8" = 1'-0"3 LEFT SCALE: 1/8" = 1'-0"4 RIGHT Keynote Legend Key Value Keynote Text B2 COLUMN BRACKET - 1'-7" WIDE X 2-7" HIGH B3 DECORATIVE BRACKET - FYPON BKT25X27 C1 COLUMN WRAP - OR - TRIM OUT COLUMN F1 6" ALUMINUM FASCIA OR 6" ALUMINUM RAKE L1 EXTERIOR WALL LIGHT M1 MASONRY- CULTURED STONE M2 MASONRY- STONE CAP R1 LAMINATED ASPHALT ROOF SHINGLES S1 (LAP SIDING) HARDIE-PLANK SIDING-7" MAX EXPOSURE S3 (BOARD AND BATTEN SIDING) VERTICAL SIDING AND HARDIE TRIM T1 PAINTED HARDIE CORNER TRIM T2 4" PAINTED TRIM T4 6" OVER 8" PAINTED TRIM T5 7" OVER 12" PAINTED TRIM T7 4" TRIM AT WINDOWS ON FRONT ELEVATION ONLY 1X3 BATTENS ON SMOOTH PANEL SIDING SEE ROOF PLAN 36" PLASTIC ATTIC CHUTE SNOW AND ICE BARRIER EXTEND 24" PAST I.S. FACE OF EXTERIOR WALLS LAMINATED ASPHALT ROOF SHINGLES ON 15# ROOF FELT ON 1/2" O.S.B. SHEATHING MTL. DRIP 2X6 SUB-FASCIA 3/8" VENTED ALUMINUM SOFFIT & FASCIA ON 2X4 LOOKOUTS @ 24" O.C. 7" OVER 12" PAINTED TRIM SEE ELEVATIONS FOR SIDING MATERIAL WEATHER RESISTANT BARRIER OVER 1/2" O.S.B. SHEATHING ON 2X6 WALL STUDS @16" O.C. R21 INSULATION 1/2" GYP. BD. ON 6MIL POLY VAPOR BARRIER FLASHING (ALL HORIZ. JOINTS) 2X6 SILL PLATE "TRTD" ON CLOSED CELL FOAM SILL SEALER R49 BLOWN INSULATION 12 SE E R O O F PL A N MAIN FLOOR 12 " E N E R G Y H E E L M I N . T.O.F. 0'-0" 0'-4" FOUNDATION WALL-REFER TO PLAN TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL MAIN FLOOR PLT. HT. 9'-1 1/8" HOLD ALL TRIM AND SIDING MIN. 6" ABOVE GRADE 9' - 1 1 / 8 " CONTINUOUS BEAD OF SEALANT 4"4" 4' - 0 " LINE OF GRADE (VARIES) 2" 4" 2' - 0" HOLD ALL TRIM AND SIDING MIN. 6" MIN. ABOVE GRADE MAIN FLOOR 0'-0" TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL CONTINUOUS BEAD OF SEALANT 4"4" 2" 4" 2' - 0"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE GARAGE SLAB (SLOPE TO OVERHEAD DOOR) MAIN FLOOR 0'-0" TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL CONTINUOUS BEAD OF SEALANT 4"4" 2" 2' - 0"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE SLAB (SLOPE AWAY FROM HOUSE) MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 3' - 3"3' - 0"3' - 3" 9' - 6" 2' - 1 0 1 / 2 " 1 1 / 2 " 1' - 6 " 3' - 0 " 7' - 6 " 3' - 3"3' - 0"3' - 3" 9' - 6" MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 1"2' - 0"3' - 0"1' - 6"1' - 6"1" 8' - 2" 2' - 1 0 1 / 2 " 1 1 / 2 " 3' - 0 " DW MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 2' - 1 0 1 / 2 " 1 1 / 2 " 1' - 6 " 3' - 0 " 7' - 6 " 2' - 6"2' - 6 1/2"1' - 6"1' - 3"1' - 3"3' - 0 1/2" 12' - 1" 2' - 6"2' - 6"1' - 6"1' - 3"1' - 3" 1/2" 3' - 0"1/2" 1' - 6 " 6' - 0 " 7' - 6 " REF. MW HOOD RANGE 12' - 1" MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 2' - 1 0 1 / 2 " 1 1 / 2 " 1' - 6 " 3' - 0 " 7' - 6 " REF. MW HOOD RANGE PANTRY 1' - 9"2' - 6 1/2"1' - 6" 5' - 9 1/2" 6' - 0 " 1' - 6 " 7' - 6 " 1' - 9"2' - 6"1' - 6"3' - 0" 8' - 9" MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 1"4' - 0"3' - 3 1/2"4' - 0"1" 11' - 5 1/2" 2' - 1 0 1 / 2 " 1 1 / 2 " 3' - 0 " MAKEUP 2' - 4 1 / 2 " 1 1 / 2 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 3' - 0" 2' - 1 0 1 / 2 " 1 1 / 2 " 3' - 0 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" W/D4' - 6 " 3' - 0 " 7' - 6 " 2' - 6"2' - 6" 5' - 0" 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A201 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y ME N D O C I N O E S T A T E V 2 DE T A I L S WINDOW SCHEDULE From Room: Name Type Comments BATH 2935 CSMT E3 DINING 2959 CSMT E DINING 5359 FXD DINING 2959 CSMT E BEDROOM 1 2959 CSMT E BEDROOM 1 2959 CSMT E BEDROOM 1 2959 CSMT E 2925 TRSM GABLE 2925 TRSM GABLE 2925 TRSM GABLE 2929 TRSM GABLE MASTER BEDROOM 2959 CSMT E MASTER BEDROOM 5359 FXD MASTER BEDROOM 2959 CSMT E LAUNDRY 2929 TRSM MASTER BEDROOM 2929 TRSM MASTER BEDROOM 2959 CSMT E MASTER BEDROOM 2929 TRSM DINING 2959 CSMT E M. BATH 2917 FXD 2917 FXD LIVING ROOM 2959 CSMT E LIVING ROOM 2959 CSMT E 2959 CSMT E BEDROOM 2 2947 CSMT E BEDROOM 2 2947 CSMT E LIVING ROOM 2959 CSMT E LIVING ROOM 2959 CSMT E 5359 FXD LIVING ROOM 2959 CSMT E Grand total: 30 NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL SCHEDULES PRIOR TO BIDDING AND CONSTRUCTION. VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION. DOOR SCHEDULE Level Type To Room: Name Door CommentsWidth Height Material Finish MAIN FLOOR 3/0 x 6/8 Sliding Door 3' - 0" 6' - 8" MAIN FLOOR 2/4 x 6/8 2' - 4" 6' - 8" MAIN FLOOR 2/10 x 6/8 BATH 2' - 10" 6' - 8" MAIN FLOOR 2/10 x 6/8 BEDROOM 1 2' - 10" 6' - 8" MAIN FLOOR 3/0 x 6/8 BEDROOM 2 3' - 0" 6' - 8" MAIN FLOOR 2/6 x 6/8 CLOSET 1 2' - 6" 6' - 8" MAIN FLOOR 2/6 x 6/8 CLOSET 2 2' - 6" 6' - 8" MAIN FLOOR 7282 SLDR DINING 6' - 0" 6' - 10" MAIN FLOOR 3/0 x 6/8 FOYER 3' - 0" 6' - 8" MAIN FLOOR 6/0 x 6/8 FOYER 6' - 0" 6' - 8" MAIN FLOOR 2/10 x 6/8 LAUNDRY 2' - 10" 6' - 8" MAIN FLOOR 2/10 x 6/8 PCKT 2 M. BATH 2' - 10" 6' - 8" MAIN FLOOR 2/10 x 6/8 M. BATH 2' - 10" 6' - 8" MAIN FLOOR 2/10 x 6/8 M. BATH 2' - 10" 6' - 8" MAIN FLOOR 2/10 x 6/8 M. CLOSET 2' - 10" 6' - 8" MAIN FLOOR 3/0 x 6/8 MASTER BEDROOM 3' - 0" 6' - 8" MAIN FLOOR 3/0 x 6/8 MECH 3' - 0" 6' - 8" MAIN FLOOR 3/0 x 6/8 MUD 3' - 0" 6' - 8" MAIN FLOOR 34" x 80" MUD 0" 0" MAIN FLOOR 2/6 x 6/8 MUD 2' - 6" 6' - 8" MAIN FLOOR 2/6 x 6/8 PANTRY 2' - 6" 6' - 8" T.O.F. 16'-0" x 8'-0" TWO CAR GARAGE 16' - 0" 8' - 0" NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL SCHEDULES PRIOR TO BIDDING AND CONSTRUCTION. VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION. ROOM FINISH SCHEDULE- OVERALL ROOM NO ROOM NAME AREA FLOOR BASE WALLS CEILING NOTESN E S W FINISH HEIGHT 35 BEDROOM 1 130 SF CARPET 36 BEDROOM 2 118 SF CARPET 37 LIVING ROOM 195 SF LVP 38 KITCHEN 277 SF LVP 39 MASTER BEDROOM 215 SF CARPET 40 M. BATH 136 SF LVT 41 PANTRY 23 SF LVP 42 LAUNDRY 67 SF LVP 43 M. CLOSET 72 SF CARPET 45 BATH 50 SF LVT 46 FOYER 133 SF LVP 47 MUD 89 SF LVP 48 DINING 158 SF LVP 49 TWO CAR GARAGE 506 SF CONCRETE 50 CLOSET 2 20 SF CARPET 51 MECH 71 SF CONCRETE 52 CLOSET 1 21 SF CARPET 53 CL 2 10 SF LVP 54 CL 1 18 SF LVP NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL SCHEDULES PRIOR TO BIDDING AND CONSTRUCTION. VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION. SCALE: 1/2" = 1'-0"1 TYPICAL SLAB ON GRADE WALL SECTION SCALE: 1" = 1'-0"2 TYP. ZERO ENTRY DETAIL - GARAGE SCALE: 1" = 1'-0"3 TYP. ZERO ENTRY DETAIL - STOOP SCALE: 1/4" = 1'-0"4 KITCHEN ELEVATION 2 SCALE: 1/4" = 1'-0"5 KITCHEN ISLAND ELEVATION SCALE: 1/4" = 1'-0"6 KITCHEN ELEVATION 1 SCALE: 1/4" = 1'-0"7 KITCHEN ELEVATION - OPTION B SCALE: 1/4" = 1'-0"8 MASTER BATH ELEVATION SCALE: 1/4" = 1'-0"9 BATH ELEVATION SCALE: 1" = 1'-0"10 TERMITE GUARD SCALE: 1/4" = 1'-0"11 LAUNDRY ELEVATION GENERAL NOTES B. Submit floor truss layouts showing beam locations, joist layout, locations of continuous duct chases, and maximum duct size in each chase. Allow designer five days for complete review. lumber package. Allow designer five days for complete review. manufacturer for review prior to ordering roof trusses and/or roof A. Submit roof truss and/or rafter layout plan as completed by the 12. SUBMITTALS 8. DOORS AND WINDOWS A. Exterior doors shall be selected by the Owner. B. House-to-garage doors shall be fire rated doors approved by governing codes. Face design to be selected by the Owner. C. Interior doors shall be selected by the Owner. D. Exterior windows by Pella Corp as selected by owner. E. Glazing in all doors and windows shall comply with governing codes. F. Install egress window units in accordance with governing codes. G. Door and window sizes indicated or drawings are as follows: "3/0x6/8" represents a door or window 3'-0" wide x 6'-8" high. Jamb depth to be coordinated by the Contractor. H. Finish hardware shall be selected by the owner. Install hardware in accordance with governing codes. 9. FINISHES A. Gypsum wallboard, unless noted otherwise, shall be provided as follows: 1. Exterior walls: One layer 1/2" regular wallboard to interior face. 2. Interior walls: One layer 1/2" regular wallboard each face. 3. Ceiling: One layer 5/8" regular wallboard. 4. Garage/House common wall: One layer 5/8" type "X" wallboard each face. 5. Baths: Water resistant wallboard at all walls and ceilings surrounding tubs and showers and as required by governing codes. Provide cement board as substrate for ceramic tile. B. Provide metal corner bead and trim at all locations recommended by the gypsum wallboard manufacturer. C. Tape, float, and sand joints and fasteners of gypsum wallboard with three coats of joint compound as required to obtain a uniformly smooth surface. D. Finishes shall be selected by the Owner. 10. PLUMBING, MECHANICAL, AND ELECTRICAL A. Plumbing, mechanical, and electrical information and layouts shown on the Drawings is schematic in design, and shall be reviewed by sub-contractors, suppliers, and building officials for compliance with governing codes and good common construction practices. The Architect shall be notified by the Contractor of any discrepancies prior to construction. B. Plumbing, mechanical, and electrical equipment shall be selected by the Owner. C. Design and installation of plumbing, mechanical, and electrical equipment shall be the responsibility of the appropriate licensed contractors and sub- contractors. Design shall be submitted for owner's review prior to ordering D. Service panels shall be selected by the electrical sub-contractor. E. All HVAC equipment shall be individually switched. F. All outdoor, bath, and garage and spa wall receptacles shall be provided with ground fault circuit protection in accordance with governing codes. G. Dryer vents shall be extended to the exterior. H. Provide plumbing vents in accordance with governing codes. Minimize number and locate for minimal visual impact. I. Install type and number of smoke detectors in accordance with governing codes & UL217. J. Connect water, gas, and electric services in accordance with governing codes. 11. MISCELLANEOUS and installation of equipment. exterior walls install plates over foam sill sealer. C. Unless noted otherwise, all slabs on grade shall be 4" thick, reinforced with 6x6 W1.4xW1.4 W.W.M., and placed over 4" minimum compacted sand or gravel fill. Interior slabs shall be placed over 6 mil. Stabilized polyethylene vapor barrier. Coordinate with radon removal procedures. D. Footing sizes shown are typical only for stated soil pressure and consistent compaction. Contractor shall be responsible for footings complying with A. Adhered masonry flashing must be installed at wall penetrations and terminations integrated with the WRB properly (when used), and installed in accordance with the to ensure a consistent overall project color on the wall. C. Install in accordance with manufacturer's installation instructions. Visit this page for http://ncmabr.org/pdfs/masterlibrary/MVMA%20Installation%20Guide%204th%20Edition%20web.pdf Consult manufacturer for proper installation instructions. modified mortar meeting ANSI A118.4 OR ANSI 118.15. F. Touch-up, repair or replace damaged stone before completion of project. A. All structural steel shall comply with appropriate ASTM Specifications as follows: ASTM A36, ASTM A53, ASTM A501, ASTM A307, and ASTM A. Lumber shall, in addition to complying with governing codes, comply with: 1. "Product Use Manual" of the Western Wood Products Association for selection and use of products included in that manual. 2. "Plywood Specification and Grade Guide" of the American Plywood 3. "Standard Specifications for Grades of California Redwood Lumber" of 4. American Wood Preservers Association standards and recommendations for fire-retardate and preservative pressure treated lumber and plywood. 5. Western Red Cedar Lumber Association standards and recommendations the Redwood Inspection Bureau for Redwood. for cedar. Association. D. Application details and mortar recommendations may vary depending on the stone style. E. All dry-stacked and large format standard stones must be applied using a polymer - 5. METALS A325. 6. WOOD AND PLASTICS the design requirements of specific soil conditions. of the stone veneer. Assure that all flashing and kickouts are corrosion resistant, local building code requirements. B. Product should be pulled from a variety of boxes and blended on site during intalllation installation instructions: 4. MASONRY Install skylights according to the manufactures' recommendations. I. Install water and ice barrier (Bituthene or equal) over roof sheathing at all eaves and valleys. water & ice barrier to extend 24" past outside face of L. Provide 2" nominal pressure treated lumber over foam sill sealer beneath full bearing of wood beams bearing on concrete or 7. THERMAL AND MOISTURE PROTECTION A. Provide thermal building insulation at assemblies adjacent to exterior or unheated spaces meeting the requirements of governing codes and, unless noted otherwise, meeting the following minimum requirements: 1. Foundations: 1 1/2"extruded polystyrene (R-10) 2. Walls: glass fiber batt (R-20) U.N.O. 3. Floors: glass fiber batt (R-30) -for floors over unconditioned space or exterior 4. Ceilings: glass fiber batt (R-49) 5. Install continuous blankets without holes for electrical boxes, lighting fixtures, or heating ductwork. B. Install 6 mil. stabilized polyethylene vapor barrier against interior face of all C. Waterproof foundation walls at excavated areas from footing to finished grade with two coats of asphalt based waterproofing compound for full basements. D. Roofing shall be 240 lb. (minimum) composition shingles installed over 15 lb. roof felt on roof sheathing. Minimum slope, fasteners, under layment, and exposure according to manufacturers' recommendations. E. Provide flashing and sheet metal required to prevent penetration of water through the exterior shell of the building. In addition to complying with governing codes, comply with pertinent recommendations contained in the current edition of "Architectural Sheet Metal Manual" published by SMCNA. All iron sheet metal flashing shall be hot-dipped galvanized complying with F. Provide gutters and downspouts to provide positive roof and site drainage. G. Provide attic and roof ventilation as required by governing codes and as shown on the Drawings. Provide appropriate soffit and roof vents. H. Skylights shall be selected by the Contractor and approved by the owner. ASTM A93. thermal insulation. masonry. 1. Before final Drawings and Specifications are issued for construction, they shall be submitted to all governing building agencies to insure their compliance with all applicable local and national codes. If code discrepancies in Drawings and/or Specifications appear, the Architect shall be notified of such discrepancies in writing by the Contractor or building official, and allowed to alter the drawings and specifications so as to comply with governing codes before construction begins. 2. Upon written receipt of approval from the governing official, approved final Drawings and Specifications shall be submitted to the Contractor by 3. If code discrepancies are discovered during the construction process, the Architect shall be notified and allowed ample time to remedy said 4. All work performed shall comply with all applicable local, state and national building codes, ordinances and regulations, and all other B. All contractors, suppliers, and fabricators shall be responsible for the content of the Drawings, and for the supply and design of appropriate C. All manufactured articles, materials, and equipment shall be handled, applied, installed, erected, used, cleaned, and conditioned in strict accordance with the D. All alternates are at the option of the Owner and shall be at the Owner's request, constructed in addition to or in lieu of the typical construction, as dead load 15psf (10 psf top, 5psf bottom) dead load 15psf (10 psf top, 5psf bottom) 5. Prior to start of construction, verify design loads with governing codes and site conditions. Check with local building agencies for wind, seismic, snow and other special loading conditions. If discrepancies are discovered, Architect shall be notified according to Section 1.A.1 above. A. Perform excavation, according to good common construction practices, to the lines, grades, and elevations indicated on the Drawings. B. Provide consistent compaction of the top 8" of sub-grade, fill, and backfill material beneath structures, walks, and pavements to meet the stated soil C. Provide soil poisoning to control termites as required by governing codes. D. Provide and install ventilation for Radon Gas as required by local building A. Provide concrete complying with ASTM C94. Unless otherwise noted, concrete shall have the following 28 day compressive strengths as minimums: 2. Concrete floor slabs, walks, drives, and patios: 3,500psi 3. Provide construction joints so panel size does not exceed 400sf. B. Provide reinforcement of the size and spacing indicated on Drawings. Reinforcing shall comply with the following minimums: live load 60psf (maximum) live load 40psf (maximum) live load 30psf (maximum) agencies and governing codes. 1. Concrete footings and foundations: 3,000psi 1. Bars: ASTM A615, grade 40, deformed bars. 2. Welded Wire Fabric: ASTM A185. 3. CONCRETE 2. SITE WORK pressure. materials and work performance. manufacturers' requirements. indicated on the Drawings. 3. Balconies and Decks: 4. Soil Pressure: 1500 psf (minimum) 2. Floor: 1. Roof: E. Design Loads: dead load 10psf 1. GENERAL REQUIREMENTS authorities having jurisdiction. discrepancies. the Architect. A. Codes: drawings to designer for review prior to construction. spacing of all trusses. Contractor to submit truss drawings and/or roof framing b. Install joist and beam hangers capable of supporting the maximum allowable load of joist or beam being supported. C. Provide "Micro-Lam" glue laminated veneer lumber beams (manufactured by Truss Joist Corporation) or equal, of the dimensions and number indicated on the drawings. Provide exterior grade Micro Lams for deck framing and other in strict accordance with manufacturers' recommendations. a. Modulus of elasticity: 2,000,000 psi b. Flexural (12" depth): 2,900 psi c. Horizontal shear: 285 psi D. Provide wood trusses able to sustain the stated loads for the spans, profiles, and arrangement shown on the Drawings. Truss layout is schematic only. Truss manufacturer and/or engineer shall be responsible for the design and E. All roof trusses shall be installed with metal truss seats as specified by the F. Unless noted otherwise, provide: 1. Double header joists and trimmers at all floor openings. 2. Double joists under all partitions parallel to joists. 3. Double 2x12 headers with 1/2 OSB between at all door and window openings in 2x4 walls. Triple 2x10 headers with 1/2" OSB between at all door and window openings at 2x6 walls. 4. For solid sawn joists, provide one row of 1x3 cross-bridging or metal bridging G. Stud spacing at all exterior and bearing walls shall be 16" o.c. minimum. H. Stud walls shall not exceed the following heights without continuous lateral support perpendicular to the plane of the wall at the stated height or less. Studs shall be continuous between points of lateral support. I. Unless noted otherwise, rafters, ceiling joists, collar ties, and purlins shall be sized and spaced in accordance with FHA requirements or governing codes, J. Stair construction shall consist of (3)2x12 stringers, 5/4" or 2x thick tread and 3/4" thick risers or, shall be fabricated by component manufacturer. K. All wood plates bearing on concrete or masonry shall be pressure treated. At b. 2x6: 12'-0' 2. Non-bearing walls: a. 2x4: 14'-0" b. 2x6: 20'-0" whichever is more restrictive. 1. Bearing walls: a. 2x4: 10'-0" for each 8'-0" of joist span. d. Bearing: 550 psi truss manufacturer. 1. Allowable stresses: B. Provide lumber and materials meeting or exceeding the following standards of a. Studs: Douglas Fir-Larch, Stud Grade -or as approved by building code. b. Headers and Beams: Douglas Fir -Larch, No. 2 and better -or as appoved by building code. 2. All headers and beams shall be free from splits, checks, and shakes. a. Roof: 1/2" OSB APA RATED SHEATHING, EXP 1. b. Walls: 1/2" OR 7/16" OSB APA RATED SHEATHING, EXP 1. c. Floor: 23/32" plywood APA RATED SHEATHING, EXP 1. d. Proper oriented strand board may be substituted for plywood. steel at exterior locations. a. Steel items: Comply with ASTM A36; use galvanized 3. Sheathing: (with clips) (glue and nail) 4. Rough Hardware: 1. Framing Members: quality: Contractor to submit steel shop drawings to designer or a licensed structural Construction and shall be detailed by a qualified structural steel detailer. B. All steel connections shall be designed according to AISC Manual of Steel engineer prior to steel erection. C. Architect will not be responsible for any errors in the roof and/or floor framing without the opportunity to review the roof and/or floor framing layouts. Framing layouts, member sizes, and floor/roof penetrations indicated on the drawings are for design intent only. Final layouts shall be the responsibility of builder. exterior applications. Unless noted otherwise, fasten multiple beams together exterior wall below. And as shown on the roof plan. A. This set of construction drawings is intended for design intent only. Although many jurisdictions will accept these drawings as sufficient for a construction permit, these drawings are not intended, and should not be construed, as a complete set of construction drawings. These drawings will have to be adapted to meet local zoning and/or site conditions and additional detailing will need to be completed on site by the builder. B. Install prefabricated fireplace units as shown on Drawings. 1. Fireplace units shall be "Heat -N-Glo" or as approved by Owner. 2. Contractor shall be responsible for proper installation as recommended by the manufacturer and as required by governing codes, including mantel and hearth design and location. C. Room sizes shown on the plans indicate room dimensions prior to installation of gypsum wall board. Gypsum wall board thickness must be subtracted from room sizes indicated for actual room dimensions and are subject to change. 2. Use exterior grade Micro-Lam in all areas subject to moisture. 3. Hearth shall be of non-combustible material. EARTH RIGID INSULATION CONCRETE BLOCK CONCRETE BRICK PLYWOOD STEEL OR STEEL STUD WALL BATT INSULATION GYPSUM BOARD GRAVEL WOOD OR WOOD STUD WALL SOUND INSULATION IN WALL MIN. (3) 2X SOLID BLOCKING BEARING WALL MATERIALS ELEVATION DRAWING NUMBER WALL TYPE SHEET NUMBER SHEET NUMBER SECTION DRAWING NUMBER DETAIL DRAWING NUMBER SHEET NUMBER POINT LOAD FROM ABOVE ELEVATION HEIGHT ELEVATION TYPE W2 SYMBOLS VINTAGE COOP PLAN INFORMATION PLAN OPTION: FOUNDATION: ROOF TRUSS: MONTEREY ESTATE SLAB ON GRADE UPPER FLOOR BONUS ROOM FULL BASEMENT STANDARD ROOF TRUSSES 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : IS S U E D F O R : 11 - 2 3 - 2 0 FO R C O N S T R U C T I O N 11 - 3 0 - 2 0 RE V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 RE V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 OW N E R R E Q U E S T E D C H A N G E S A0 19-137.2 3-18-2021 MS P L A N LR KC VI N T A G E E S T A T E S - N O R T H L I B E R T Y MO N T E R E Y E S T A T E V 1 TI T L E S H E E T SHEET LIST Sheet Number Sheet Name A0 TITLE SHEET A100 FOUNDATION PLAN A101 MAIN FLOOR PLAN A200 ELEVATIONS A201 DETAILS AREA SCHEDULE Level Name Area MAIN FLOOR MAIN FLOOR 1989 SF MAIN FLOOR GARAGE 502 SF Grand total: 2 2490 SF NOTE: THIS DRAWING IS AN ARTISTIC INTERPRETATION OF THE GENERAL APPEARANCE OF THE DESIGN. IT IS NOT INTENDED TO BE AN EXACT RENDITION. MAIN FLOOR 0" T.O.F. -6" B.O.F. -4' -0" W3W2 ***VERIFY ALL CHANGES IN WALL ELEVATION ON SITE. MAINTAIN 42" MINIMUM FROST PROTECTION AT ALL TIMES ***ALL FOUNDATION STEP- DOWNS TO BE DETERMINED ON SITE AS GRADE ALLOWS DROP T.O.F. @ O.H.D.- VERIFY W/ GRADE 4' - 0 " 8" 1' - 0 " 3' - 0 " 8" 8" 8" W1 6" 3' - 6 " 8" 8" 1' - 4"1' - 4"1' - 4" 1' - 4" 10 " CF16W4 6" 3' - 6 " 8" 8" 1' - 4" MA I N T A I N 4 2 " M I N I M U M FR O S T P R O T E C T I O N A T A L L T I M E S NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL NOTE: STEP FOOTINGS DOWN AS GRADE REQUIRES. MAINTAIN MINIMUM FROST PROTECTION AT ALL TIMES. NOTE: STEP FOUNDATION DOWN AS GRADE REQUIRES. MAINTAIN 42" MINIMUM FROST PROTECTION ON ALL FOOTINGS NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL PATIO ABOVE NOTE: CHANGES IN FOOTING AND FOUNDATION WALL ELEVATIONS ARE FOR DESIGN INTENT ONLY. ACTUAL ELEVATIONS SHALL BE VERIFIED W/FINAL GRADE DURING CONSTRUCTION. MAINTAIN 42" MINIMUM FROST PROTECTION ON ALL FOOTINGS. STEP DOWN FOOTING @ O.H.D. STOOP ABOVE 2' - 10"16' - 4"2' - 10" 16' - 0"14' - 4"11' - 8" 42' - 0" 46 ' - 8 " 22 ' - 0 " 2' - 0 " 70 ' - 8 " 7' - 8 " 11 ' - 4 " 38 ' - 8 " 11 ' - 0 " 2' - 0 " 70 ' - 8 " 22' - 0"11' - 0"9' - 0" 42' - 0" W4 W4 W4 W1 W2 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W4 W2 W2 2' - 4 " 8' - 4 " 8"22' - 0"18' - 8" 10 ' - 4 " 2' - 0 " W3 TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL DOWEL STOOP SLAB TO FOUNDATION -VERIFY ALL CHANGES IN WALL ELEVATION ON SITE -MAINTAIN 42" MINIMUM FROST PROTECTION AT ALL TIMES POST P20 FOOTING F30 F24 CF16 1'-8'' 2'-6'' 2'-0'' 1'-4'' DIA 2'-6'' 2'-0'' CONT 4'-0'' 1'-0'' 1'-0'' 10'' (2) #4 CONT. #4 AT 12" O.C. E.W. #4 AT 12" O.C. E.W. (2) #4 CONT. -NOT ALL TYPES ARE USED F36 3'-0'' 3'-0'' 1'-0'' #4 AT 12" O.C. E.W. 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A100 19-137.2 3-18-2021 MS P L A N ML K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y MO N T E R E Y E S T A T E V 1 FO U N D A T I O N P L A N SCALE: 1/4" = 1'-0"2 FOOTING LEGEND SCALE: 1/4" = 1'-0"1 FOUNDATION PLAN FOUNDATION SCHEDULE Type Mark WALL FOOTING Width Unconnected Height Hotizontal Reinforcements Vertical Reinforcements Footing Width Footing Length Footing Depth Footing Reinforcing W1 8" 3' - 6" #4 @ TOP & BOT. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. W2 8" 4' - 0" #4 @ TOP & BOT. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. W3 8" 3' - 0" #4 @ TOP & BOT. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. W4 8" 3' - 6" #4 @ TOP & BOT. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. DW DW A2004 A200 A200 A200 2 3 1 3' - 0"16' - 0"3' - 0"11' - 0"9' - 0" 42' - 0" BEDROOM 1 BEDROOM 2 LIVING ROOM KITCHEN MASTER BEDROOM M. BATH PANTRY 3/ 0 X 6 / 8 BA R N D O O R LAUNDRY M. CLOSET BATH FOYER MUD COVERED PORCH OPTIONAL PATIO DINING R/ S 70 ' - 8 " 5' - 6"5' - 6"6' - 9"2' - 3" 2' - 0 " 11 ' - 0 " 38 ' - 8 " 11 ' - 4 " 7' - 8 " 70 ' - 8 " TWO CAR GARAGE CLOSET 2 3/0 x 6/8 2/ 1 0 x 6 / 8 W. C . 2/6 x 6/8 3/0 x 6/8 2/ 1 0 x 6 / 8 2/ 1 0 x 6 / 8 2/10 x 6/8 2/10 x 6/8 2/ 1 0 x 6 / 8 2/10 x 6/8 PCKT 3/ 0 x 6 / 8 72 8 2 S L D R 5359 FXD 2959 CSMT 29 2 9 T R S M 29 2 9 T R S M 8' - 0"8' - 0"6' - 9 1/2"7' - 6 1/2"6' - 8"5' - 0" 16' - 0"14' - 4"11' - 8" 5359 FXD2959 CSMT 2959 CSMT 29 5 9 C S M T 2959 CSMT 2959 CSMT 29 4 7 C S M T 2- 2/ 6 x 6 / 8 29 2 9 T R S M 2935 CSMT 2959 CSMT3- 16/0 X 8/0 O.H.D. O.H.C. O. H . C . O. H . C . 29 1 7 F X D 42' - 0" 2' - 6 " 5' - 2 " 4' - 9 " 6' - 7 " 15 ' - 9 " 6" 22 ' - 0 " 9' - 4 " 5' - 2 " 4' - 1 0 " 5' - 2 " 2' - 5 1 / 2 " 4' - 4 1 / 2 " 14 ' - 4 " 6" 6" 11 ' - 7 " 4' - 1 0 1 / 2 " 2' - 0 1 / 2 " 4' - 4 " 1' - 2 " 7' - 8 " 3 1 / 2 " 1' - 1 0 1 / 2 " 16 ' - 1 0 " 6" 10 ' - 1 0 " 6" 6/ 0 x 6 / 8 GIRDER TRUSS ABOVE 6" 21' - 6" 6" 2' - 6"5' - 2 1/2"5' - 6"5' - 9 1/2" 6" 6" 7' - 6"5' - 4"2' - 2"14' - 8 1/2"11' - 3 1/2"6" 6" 6' - 3"4' - 4 1/2"4' - 4 1/2"3 1/2"14' - 0 1/2"6" 2' - 0 " 22 ' - 0 " 46 ' - 8 " 2' - 6 " 10 ' - 4 " 4' - 7 " 7' - 3 1 / 2 " 14 ' - 1 1 / 2 " 7' - 4 " 6" EQ EQ O. H . C . R/ S 32X60 TUB/SHWR VA U L T E D VA U L T E D NOTE: WALLS AND CEILING TO BE FINISHED W/ 5/8" TYPE "X" FIRE CODE GYPSUM BOARD LINE OF O.H.D. IN OPEN POSITION GIRDER TRUSS ABOVE LO C K E R S MECH D W 3/ 0 x 6 / 8 NOTE: DIMENSIONS AND ROOM SIZES ARE SHOWN FOR DESIGN PURPOSES ONLY. DUE TO CONSTRUCTION MEANS, METHODS AND TOLERANCES, ROOM SIZES ARE SUBECT TO CHANGE WITHOUT NOTICE. 6"7' - 6"2' - 6 1/2"4' - 11 1/2"9' - 6"5' - 2 1/2"11' - 3 1/2" 6" 6' - 8 " 4' - 4 1 / 2 " 12 ' - 5 1 / 2 " 6' - 6 1 / 2 " 7' - 1 1 1 / 2 " 6" 11'-2" PEAK 2/ 1 0 X 6 / 8 O P E N I N G RA N G E RE F 2' - 0" HB HB POCKET DOOR OPTIONAL POCKET DOOR NICHE OPTIONAL 12" TRAY 12" TRAY CLG. 12" TRAY CLG. FURN WH COVERED PORCH 2 A201 Sim 3 A201 Sim SHELVES 29 1 7 F X D 8' - 6 " H . H . 8' - 6 " H . H . 2959 CSMT2- GL A S S 5' - 1 0 " 1' - 0 " 10' - 0" A101 3 PLUMB WALL AS REQ'D 1' - 0" 3/ 6 X 6 / 8 OP E N I N G SL O P E S L A B 6 " T O OV E R H E A D D O O R 0'-0" -0'-2" 2/6 x 6/8 9' - 2 1 / 2 " 4' - 1 0 " 3/ 0 x 6 / 8 F.D. ATTIC ACCESS ABOVE 135.00° 2/6 x 6/8 CLOSET 1 5' - 8"1' - 8 3/4" CL 1 CL 2 W.C.A101 4 29 5 9 C S M T 53 5 9 F X D 29 5 9 C S M T 8' - 1 1 " 14 ' - 0 " A2015 MA K E U P LA V LA V . L A V . 6 7A201 A2019 A201 10 O. H . C . A20111 (2) 1 3/4x11 7/8 LVL HDR (2) 1 3/4x11 7/8 LVL HDR 3' - 4" SI N K 8' - 4 " ROOF NOTES: 2'-0" EAVE OVERHANG*** 1' - 6" GABLE RAKES*** 10:12 SLOPE SIDE TO SIDE*** 6:12 SLOPE FRONT TO BACK*** ***UNLESS NOTED OTHERWISE PROVIDE RIDGE, HIP AND SOFFIT VENTING TO COMPLY W/ GOVERNING CODES SNOW AND ICE BARRIER ALONG ALL EAVES & RAKES 2' - 0" PAST OUTSIDE FACE OF FRAMING (TYPICAL @ ALL EXTERIOR EAVES) OUTSIDE FACE OF FRAMING BELOW 4 1 / 2 " / 1 2 " 4 1 / 2 " / 1 2 " 10" / 12"10" / 12" 1' - 6"1' - 6" 2' - 0 " 1' - 6" 2' - 0 " 2' - 0 " 1' - 6" 2' - 0 " RIDGE VALLEY V A L L E Y RI D G E RI D G E RI D G E VALLEYV A L L E Y 2' - 0 " 2' - 0"2' - 0" 10" / 12"10" / 12" VALLEY V A L L E Y RI D G E 10" / 12"10" / 12" 4' - 0 " DR O P Z O N E O. H . C . LO C K E R S RA N G E MUD 3/ 0 X 6 / 8 BA R N D O O R 2/4 x 6/8 PANTRY 3/ 0 x 6 / 8 2/ 1 0 x 6 / 8 3/0 x 6/8 A2018 SI M 29 5 9 C S M T 29 5 9 C S M T 2959 CSMT VA U L T E D VA U L T E D 11'-2" PEAK OP T . FP 2' - 1 0 1 / 2 " 2' - 1 0 1 / 2 " 5' - 4 " 2' - 1 0 1 / 2 " 2' - 1 0 1 / 2 " 2- LIVING ROOM A2015 RE F RA N G E 12 ' - 1 " 3' - 3"3' - 0"3' - 3" 9' - 6" 1' - 1 " 1' - 0 " 2' - 1 " 8' - 4 " O.H.C. MW HO O D SI N K 2' - 6 " 2' - 6 " 1' - 6 " 1' - 3 " 1' - 3 " 1/ 2 " 3' - 0 " 1/ 2 " O.H.C. O.H.C. O. H . C . O . H . C . O . H . C . O. H . C . 1" 1" 2' - 0 " 3' - 0 " 1' - 6 " 1' - 6 " 1" 1" 3/4"2' - 0"1' - 3 1/4" KITCHEN 6 7A201 3' - 4" 1' - 6 " 1' - 6 " 3' - 0 " 1' - 10 1/2" 1' - 10 1/2" 1" 4' - 0 " 3' - 3 1 / 2 " 4' - 0 " 1" 11 ' - 5 1 / 2 " MA K E U P 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A101 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y MO N T E R E Y E S T A T E V 1 MA I N F L O O R P L A N SCALE: 1/4" = 1'-0"1 MAIN FLOOR PLAN SCALE: 1/4" = 1'-0"2 ROOF PLAN SCALE: 1/4" = 1'-0"3 MUD/PANTRY - OPTION B SCALE: 1/4" = 1'-0"4 FIREPLACE OPTION SCALE: 1/4" = 1'-0"5 MONTEREY KITCHEN SCALE: 1/4" = 1'-0"6 MONTEREY BATH SCALE: 1/4" = 1'-0"7 MONTEREY MASTER BATH MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MAIN WIN. H.H. 6' -10" T.O.F. -6" R1 M1 S1 C1 L1 S3 F1 2525 TRSM 2525 TRSM 2525 TRSM 2525 TRSM 9' - 1 1 / 8 " T4 M2 T5 T7 F1 CONCRETE - SLOPE TO GRADE T7 S3 T4 F1 R1 F1 S3 T4 T7 F1 T5 T2 L1 S1 M2 M1 R1 F1 S1 T1 T2T2 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE C1 M2 M1 T5 R1 F1 T1 S1 M1 M2 L1 T2 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE S1 T1 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE C1 M1 M2 S3T2 FIREPLACE OPTION B WINDOW LOCATIONS 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A200 19-137.2 3-18-2021 MS P L A N ML K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y MO N T E R E Y E S T A T E V 1 EL E V A T I O N S SCALE: 1/4" = 1'-0"1 FRONT SCALE: 1/4" = 1'-0"2 BACK SCALE: 1/8" = 1'-0"3 LEFT SCALE: 1/8" = 1'-0"4 RIGHT Keynote Legend Key Value Keynote Text C1 COLUMN WRAP - OR - TRIM OUT COLUMN F1 6" ALUMINUM FASCIA OR 6" ALUMINUM RAKE L1 EXTERIOR WALL LIGHT M1 MASONRY- CULTURED STONE M2 MASONRY- STONE CAP R1 LAMINATED ASPHALT ROOF SHINGLES S1 (LAP SIDING) HARDIE-PLANK SIDING-7" MAX EXPOSURE S3 (BOARD AND BATTEN SIDING) VERTICAL SIDING AND HARDIE TRIM T1 PAINTED HARDIE CORNER TRIM T2 4" PAINTED TRIM T4 6" OVER 8" PAINTED TRIM T5 7" OVER 12" PAINTED TRIM T7 4" TRIM AT WINDOWS ON FRONT ELEVATION ONLY 1X3 BATTENS ON SMOOTH PANEL SIDING SEE ROOF PLAN 36" PLASTIC ATTIC CHUTE SNOW AND ICE BARRIER EXTEND 24" PAST I.S. FACE OF EXTERIOR WALLS LAMINATED ASPHALT ROOF SHINGLES ON 30# ROOF FELT ON 1/2" O.S.B. SHEATHING MTL. DRIP 8" FASCIA 2X6 SUB-FASCIA 3/8" VENTED HARDI- SOFFIT ON 2X4 LOOKOUTS @ 24" O.C. 7" TRIM ON 12" TRIM SEE ELEVATIONS FOR SIDING MATERIAL WEATHER RESISTANT BARRIER OVER 1/2" O.S.B. SHEATHING ON 2X6 WALL STUDS @16" O.C. R20 INSULATION 1/2" GYP. BD. ON 6MIL POLY VAPOR BARRIER FLASHING (ALL HORIZ. JOINTS) 2X6 SILL PLATE "TRTD" ON CLOSED CELL FOAM SILL SEALER 4" PERF. DRAIN WILE W/ SILT SLEEVE R49 BLOWN INSULATION 12 SE E R O O F PL A N MAIN FLOOR 12 " E N E R G Y H E E L M I N . 6" 2" T.O.F. 0'-0" 0'-4" FOUNDATION WALL-REFER TO PLAN TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL MAIN FLOOR PLT. HT. 9'-1 1/8" HOLD ALL TRIM AND SIDING MIN. 6" ABOVE GRADE 9' - 1 1 / 8 " CONTINUOUS BEAD OF SEALANT 4"4" 4' - 0 " LINE OF GRADE (VARIES) 2" 4" 2' - 0" MAIN FLOOR 0'-0" TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL CONTINUOUS BEAD OF SEALANT 4"4" 2" 4" 2' - 0"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE GARAGE SLAB (SLOPE TO OVERHEAD DOOR) MAIN FLOOR 0'-0" TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL CONTINUOUS BEAD OF SEALANT 4"4" 2" 2' - 0"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE SLAB (SLOPE AWAY FROM HOUSE) MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 2' - 1 0 1 / 2 " 1 1 / 2 " 1' - 6 " 3' - 0 " 7' - 6 " 2' - 6"2' - 6 1/2"1' - 6"1' - 3"1' - 3"3' - 0 1/2" 12' - 1" 2' - 6"2' - 6"1' - 6"1' - 3"1' - 3" 1/2" 3' - 0" 1' - 6 " 6' - 0 " 7' - 6 " REF. MW HOOD RANGE 12' - 1" MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 3' - 3"3' - 0"3' - 3" 9' - 6" 2' - 1 0 1 / 2 " 1 1 / 2 " 1' - 6 " 3' - 0 " 7' - 6 " 3' - 3"3' - 0"3' - 3" 9' - 6" MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 1"2' - 0"3' - 0"1' - 6"1' - 6"1" 8' - 2" 2' - 1 0 1 / 2 " 1 1 / 2 " 3' - 0 " DW MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 2' - 1 0 1 / 2 " 1 1 / 2 " 1' - 6 " 3' - 0 " 7' - 6 " REF. MW HOOD RANGE PANTRY 1' - 9"2' - 6 1/2"1' - 6" 5' - 9 1/2" 6' - 0 " 1' - 6 " 7' - 6 " 1' - 9"2' - 6"1' - 6"3' - 0" 8' - 9" MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 1"4' - 0"3' - 3 1/2"4' - 0"1" 11' - 5 1/2" 2' - 1 0 1 / 2 " 1 1 / 2 " 3' - 0 " MAKEUP 1 1 / 2 " 2' - 4 1 / 2 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 2' - 1 0 1 / 2 " 1 1 / 2 " 3' - 0 " 3' - 0" MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 4' - 6 " 3' - 0 " 7' - 6 " 2' - 6"2' - 6" 5' - 0" W/D 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A201 19-137.2 3-18-2021 MS P L A N ML K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y MO N T E R E Y E S T A T E V 1 DE T A I L S WINDOW SCHEDULE From Room: Name Type Comments BATH 2935 CSMT E3 DINING 2959 CSMT E DINING 5359 FXD DINING 2959 CSMT E M. BATH 2917 FXD LIVING ROOM 2959 CSMT E BEDROOM 1 2959 CSMT E BEDROOM 1 2959 CSMT E BEDROOM 1 2959 CSMT E BEDROOM 2 2947 CSMT E BEDROOM 2 2947 CSMT E MASTER BEDROOM 2959 CSMT E MASTER BEDROOM 5359 FXD MASTER BEDROOM 2959 CSMT E LAUNDRY 2929 TRSM MASTER BEDROOM 2929 TRSM MASTER BEDROOM 2959 CSMT E MASTER BEDROOM 2929 TRSM 2525 TRSM GABLE 2525 TRSM GABLE 2525 TRSM GABLE 2525 TRSM GABLE 2917 FXD LIVING ROOM 2959 CSMT E LIVING ROOM 2959 CSMT E 2959 CSMT E LIVING ROOM 2959 CSMT E 5359 FXD LIVING ROOM 2959 CSMT E Grand total: 29 DOOR SCHEDULE Level Type To Room: Name Door CommentsWidth Height Material Finish MAIN FLOOR 2/4 x 6/8 2' - 4" 6' - 8" MAIN FLOOR 2/10 x 6/8 BATH 2' - 10" 6' - 8" MAIN FLOOR 2/10 x 6/8 BEDROOM 1 2' - 10" 6' - 8" MAIN FLOOR 3/0 x 6/8 BEDROOM 2 3' - 0" 6' - 8" MAIN FLOOR 2/6 x 6/8 CLOSET 1 2' - 6" 6' - 8" MAIN FLOOR 2/6 x 6/8 CLOSET 2 2' - 6" 6' - 8" MAIN FLOOR 7282 SLDR DINING 6' - 0" 6' - 10" MAIN FLOOR 3/0 x 6/8 FOYER 3' - 0" 6' - 8" MAIN FLOOR 6/0 x 6/8 FOYER 6' - 0" 6' - 8" MAIN FLOOR 2/10 x 6/8 LAUNDRY 2' - 10" 6' - 8" MAIN FLOOR 2/10 x 6/8 PCKT 2 M. BATH 2' - 10" 6' - 8" MAIN FLOOR 2/10 x 6/8 M. BATH 2' - 10" 6' - 8" MAIN FLOOR 2/10 x 6/8 M. CLOSET 2' - 10" 6' - 8" MAIN FLOOR 2/10 x 6/8 M. CLOSET 2' - 10" 6' - 8" MAIN FLOOR 3/0 x 6/8 MASTER BEDROOM 3' - 0" 6' - 8" MAIN FLOOR 3/0 x 6/8 MECH 3' - 0" 6' - 8" MAIN FLOOR 3/0 x 6/8 MUD 3' - 0" 6' - 8" MAIN FLOOR 34" x 80" MUD 0" 0" MAIN FLOOR 2/6 x 6/8 MUD 2' - 6" 6' - 8" MAIN FLOOR 2/6 x 6/8 PANTRY 2' - 6" 6' - 8" T.O.F. 16'-0" x 8'-0" TWO CAR GARAGE 16' - 0" 8' - 0" NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL DOORS PRIOR TO BIDDING AND CONSTRUCTION NOTE: VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL WINDOWS PRIOR TO BIDDING AND CONSTRUCTION NOTE: VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION NOTE: GLASS SHOWER DOORS NOT INCLUDED IN SCHEDULE ROOM FINISH SCHEDULE- OVERALL ROOM NO ROOM NAME AREA FLOOR BASE WALLS CEILING NOTESN E S W FINISH HEIGHT 35 BEDROOM 1 110 SF CARPET 36 BEDROOM 2 118 SF CARPET 37 LIVING ROOM 195 SF LVP 38 KITCHEN 277 SF LVP 39 MASTER BEDROOM 215 SF CARPET 40 M. BATH 136 SF LVT 41 PANTRY 23 SF LVP 42 LAUNDRY 67 SF LVP 43 M. CLOSET 72 SF CARPET 45 BATH 50 SF LVT 46 FOYER 133 SF LVP 47 MUD 89 SF LVP 48 DINING 160 SF LVP 49 TWO CAR GARAGE 463 SF CONCRETE 50 CLOSET 2 20 SF CARPET 52 MECH 71 SF CONCRETE 53 CLOSET 1 21 SF CARPET 54 CL 1 18 SF LVP 55 CL 2 10 SF LVP NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL FINISHES PRIOR TO BIDDING AND CONSTRUCTION NOTE: VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION SCALE: 1/2" = 1'-0"1 TYPICAL WALL SECTION SCALE: 1" = 1'-0"2 TYP. ZERO ENTRY DETAIL - GARAGE SCALE: 1" = 1'-0"3 TYP. ZERO ENTRY DETAIL - STOOP SCALE: 1" = 1'-0"4 TERMITE GUARD SCALE: 1/4" = 1'-0"5 KITCHEN ELEVATION 1 SCALE: 1/4" = 1'-0"6 KITCHEN ELEVATION 2 SCALE: 1/4" = 1'-0"7 KITCHEN ISLAND ELEVATION SCALE: 1/4" = 1'-0"8 KITCHEN ELEVATION - OPTION B SCALE: 1/4" = 1'-0"9 MASTER BATH ELEVATION SCALE: 1/4" = 1'-0"10 BATH ELEVATION SCALE: 1/4" = 1'-0"11 LAUNDRY ELEVATION GENERAL NOTES B. Submit floor truss layouts showing beam locations, joist layout, locations of continuous duct chases, and maximum duct size in each chase. Allow designer five days for complete review. lumber package. Allow designer five days for complete review. manufacturer for review prior to ordering roof trusses and/or roof A. Submit roof truss and/or rafter layout plan as completed by the 12. SUBMITTALS 8. DOORS AND WINDOWS A. Exterior doors shall be selected by the Owner. B. House-to-garage doors shall be fire rated doors approved by governing codes. Face design to be selected by the Owner. C. Interior doors shall be selected by the Owner. D. Exterior windows by Pella Corp as selected by owner. E. Glazing in all doors and windows shall comply with governing codes. F. Install egress window units in accordance with governing codes. G. Door and window sizes indicated or drawings are as follows: "3/0x6/8" represents a door or window 3'-0" wide x 6'-8" high. Jamb depth to be coordinated by the Contractor. H. Finish hardware shall be selected by the owner. Install hardware in accordance with governing codes. 9. FINISHES A. Gypsum wallboard, unless noted otherwise, shall be provided as follows: 1. Exterior walls: One layer 1/2" regular wallboard to interior face. 2. Interior walls: One layer 1/2" regular wallboard each face. 3. Ceiling: One layer 5/8" regular wallboard. 4. Garage/House common wall: One layer 5/8" type "X" wallboard each face. 5. Baths: Water resistant wallboard at all walls and ceilings surrounding tubs and showers and as required by governing codes. Provide cement board as substrate for ceramic tile. B. Provide metal corner bead and trim at all locations recommended by the gypsum wallboard manufacturer. C. Tape, float, and sand joints and fasteners of gypsum wallboard with three coats of joint compound as required to obtain a uniformly smooth surface. D. Finishes shall be selected by the Owner. 10. PLUMBING, MECHANICAL, AND ELECTRICAL A. Plumbing, mechanical, and electrical information and layouts shown on the Drawings is schematic in design, and shall be reviewed by sub-contractors, suppliers, and building officials for compliance with governing codes and good common construction practices. The Architect shall be notified by the Contractor of any discrepancies prior to construction. B. Plumbing, mechanical, and electrical equipment shall be selected by the Owner. C. Design and installation of plumbing, mechanical, and electrical equipment shall be the responsibility of the appropriate licensed contractors and sub- contractors. Design shall be submitted for owner's review prior to ordering D. Service panels shall be selected by the electrical sub-contractor. E. All HVAC equipment shall be individually switched. F. All outdoor, bath, and garage and spa wall receptacles shall be provided with ground fault circuit protection in accordance with governing codes. G. Dryer vents shall be extended to the exterior. H. Provide plumbing vents in accordance with governing codes. Minimize number and locate for minimal visual impact. I. Install type and number of smoke detectors in accordance with governing codes & UL217. J. Connect water, gas, and electric services in accordance with governing codes. 11. MISCELLANEOUS and installation of equipment. exterior walls install plates over foam sill sealer. C. Unless noted otherwise, all slabs on grade shall be 4" thick, reinforced with 6x6 W1.4xW1.4 W.W.M., and placed over 4" minimum compacted sand or gravel fill. Interior slabs shall be placed over 6 mil. Stabilized polyethylene vapor barrier. Coordinate with radon removal procedures. D. Footing sizes shown are typical only for stated soil pressure and consistent compaction. Contractor shall be responsible for footings complying with A. Adhered masonry flashing must be installed at wall penetrations and terminations integrated with the WRB properly (when used), and installed in accordance with the to ensure a consistent overall project color on the wall. C. Install in accordance with manufacturer's installation instructions. Visit this page for http://ncmabr.org/pdfs/masterlibrary/MVMA%20Installation%20Guide%204th%20Edition%20web.pdf Consult manufacturer for proper installation instructions. modified mortar meeting ANSI A118.4 OR ANSI 118.15. F. Touch-up, repair or replace damaged stone before completion of project. A. All structural steel shall comply with appropriate ASTM Specifications as follows: ASTM A36, ASTM A53, ASTM A501, ASTM A307, and ASTM A. Lumber shall, in addition to complying with governing codes, comply with: 1. "Product Use Manual" of the Western Wood Products Association for selection and use of products included in that manual. 2. "Plywood Specification and Grade Guide" of the American Plywood 3. "Standard Specifications for Grades of California Redwood Lumber" of 4. American Wood Preservers Association standards and recommendations for fire-retardate and preservative pressure treated lumber and plywood. 5. Western Red Cedar Lumber Association standards and recommendations the Redwood Inspection Bureau for Redwood. for cedar. Association. D. Application details and mortar recommendations may vary depending on the stone style. E. All dry-stacked and large format standard stones must be applied using a polymer - 5. METALS A325. 6. WOOD AND PLASTICS the design requirements of specific soil conditions. of the stone veneer. Assure that all flashing and kickouts are corrosion resistant, local building code requirements. B. Product should be pulled from a variety of boxes and blended on site during intalllation installation instructions: 4. MASONRY Install skylights according to the manufactures' recommendations. I. Install water and ice barrier (Bituthene or equal) over roof sheathing at all eaves and valleys. water & ice barrier to extend 24" past outside face of L. Provide 2" nominal pressure treated lumber over foam sill sealer beneath full bearing of wood beams bearing on concrete or 7. THERMAL AND MOISTURE PROTECTION A. Provide thermal building insulation at assemblies adjacent to exterior or unheated spaces meeting the requirements of governing codes and, unless noted otherwise, meeting the following minimum requirements: 1. Foundations: 1 1/2"extruded polystyrene (R-10) 2. Walls: glass fiber batt (R-20) U.N.O. 3. Floors: glass fiber batt (R-30) -for floors over unconditioned space or exterior 4. Ceilings: glass fiber batt (R-49) 5. Install continuous blankets without holes for electrical boxes, lighting fixtures, or heating ductwork. B. Install 6 mil. stabilized polyethylene vapor barrier against interior face of all C. Waterproof foundation walls at excavated areas from footing to finished grade with two coats of asphalt based waterproofing compound for full basements. D. Roofing shall be 240 lb. (minimum) composition shingles installed over 15 lb. roof felt on roof sheathing. Minimum slope, fasteners, under layment, and exposure according to manufacturers' recommendations. E. Provide flashing and sheet metal required to prevent penetration of water through the exterior shell of the building. In addition to complying with governing codes, comply with pertinent recommendations contained in the current edition of "Architectural Sheet Metal Manual" published by SMCNA. All iron sheet metal flashing shall be hot-dipped galvanized complying with F. Provide gutters and downspouts to provide positive roof and site drainage. G. Provide attic and roof ventilation as required by governing codes and as shown on the Drawings. Provide appropriate soffit and roof vents. H. Skylights shall be selected by the Contractor and approved by the owner. ASTM A93. thermal insulation. masonry. 1. Before final Drawings and Specifications are issued for construction, they shall be submitted to all governing building agencies to insure their compliance with all applicable local and national codes. If code discrepancies in Drawings and/or Specifications appear, the Architect shall be notified of such discrepancies in writing by the Contractor or building official, and allowed to alter the drawings and specifications so as to comply with governing codes before construction begins. 2. Upon written receipt of approval from the governing official, approved final Drawings and Specifications shall be submitted to the Contractor by 3. If code discrepancies are discovered during the construction process, the Architect shall be notified and allowed ample time to remedy said 4. All work performed shall comply with all applicable local, state and national building codes, ordinances and regulations, and all other B. All contractors, suppliers, and fabricators shall be responsible for the content of the Drawings, and for the supply and design of appropriate C. All manufactured articles, materials, and equipment shall be handled, applied, installed, erected, used, cleaned, and conditioned in strict accordance with the D. All alternates are at the option of the Owner and shall be at the Owner's request, constructed in addition to or in lieu of the typical construction, as dead load 15psf (10 psf top, 5psf bottom) dead load 15psf (10 psf top, 5psf bottom) 5. Prior to start of construction, verify design loads with governing codes and site conditions. Check with local building agencies for wind, seismic, snow and other special loading conditions. If discrepancies are discovered, Architect shall be notified according to Section 1.A.1 above. A. Perform excavation, according to good common construction practices, to the lines, grades, and elevations indicated on the Drawings. B. Provide consistent compaction of the top 8" of sub-grade, fill, and backfill material beneath structures, walks, and pavements to meet the stated soil C. Provide soil poisoning to control termites as required by governing codes. D. Provide and install ventilation for Radon Gas as required by local building A. Provide concrete complying with ASTM C94. Unless otherwise noted, concrete shall have the following 28 day compressive strengths as minimums: 2. Concrete floor slabs, walks, drives, and patios: 3,500psi 3. Provide construction joints so panel size does not exceed 400sf. B. Provide reinforcement of the size and spacing indicated on Drawings. Reinforcing shall comply with the following minimums: live load 60psf (maximum) live load 40psf (maximum) live load 30psf (maximum) agencies and governing codes. 1. Concrete footings and foundations: 3,000psi 1. Bars: ASTM A615, grade 40, deformed bars. 2. Welded Wire Fabric: ASTM A185. 3. CONCRETE 2. SITE WORK pressure. materials and work performance. manufacturers' requirements. indicated on the Drawings. 3. Balconies and Decks: 4. Soil Pressure: 1500 psf (minimum) 2. Floor: 1. Roof: E. Design Loads: dead load 10psf 1. GENERAL REQUIREMENTS authorities having jurisdiction. discrepancies. the Architect. A. Codes: drawings to designer for review prior to construction. spacing of all trusses. Contractor to submit truss drawings and/or roof framing b. Install joist and beam hangers capable of supporting the maximum allowable load of joist or beam being supported. C. Provide "Micro-Lam" glue laminated veneer lumber beams (manufactured by Truss Joist Corporation) or equal, of the dimensions and number indicated on the drawings. Provide exterior grade Micro Lams for deck framing and other in strict accordance with manufacturers' recommendations. a. Modulus of elasticity: 2,000,000 psi b. Flexural (12" depth): 2,900 psi c. Horizontal shear: 285 psi D. Provide wood trusses able to sustain the stated loads for the spans, profiles, and arrangement shown on the Drawings. Truss layout is schematic only. Truss manufacturer and/or engineer shall be responsible for the design and E. All roof trusses shall be installed with metal truss seats as specified by the F. Unless noted otherwise, provide: 1. Double header joists and trimmers at all floor openings. 2. Double joists under all partitions parallel to joists. 3. Double 2x12 headers with 1/2 OSB between at all door and window openings in 2x4 walls. Triple 2x10 headers with 1/2" OSB between at all door and window openings at 2x6 walls. 4. For solid sawn joists, provide one row of 1x3 cross-bridging or metal bridging G. Stud spacing at all exterior and bearing walls shall be 16" o.c. minimum. H. Stud walls shall not exceed the following heights without continuous lateral support perpendicular to the plane of the wall at the stated height or less. Studs shall be continuous between points of lateral support. I. Unless noted otherwise, rafters, ceiling joists, collar ties, and purlins shall be sized and spaced in accordance with FHA requirements or governing codes, J. Stair construction shall consist of (3)2x12 stringers, 5/4" or 2x thick tread and 3/4" thick risers or, shall be fabricated by component manufacturer. K. All wood plates bearing on concrete or masonry shall be pressure treated. At b. 2x6: 12'-0' 2. Non-bearing walls: a. 2x4: 14'-0" b. 2x6: 20'-0" whichever is more restrictive. 1. Bearing walls: a. 2x4: 10'-0" for each 8'-0" of joist span. d. Bearing: 550 psi truss manufacturer. 1. Allowable stresses: B. Provide lumber and materials meeting or exceeding the following standards of a. Studs: Douglas Fir-Larch, Stud Grade -or as approved by building code. b. Headers and Beams: Douglas Fir -Larch, No. 2 and better -or as appoved by building code. 2. All headers and beams shall be free from splits, checks, and shakes. a. Roof: 1/2" OSB APA RATED SHEATHING, EXP 1. b. Walls: 1/2" OR 7/16" OSB APA RATED SHEATHING, EXP 1. c. Floor: 23/32" plywood APA RATED SHEATHING, EXP 1. d. Proper oriented strand board may be substituted for plywood. steel at exterior locations. a. Steel items: Comply with ASTM A36; use galvanized 3. Sheathing: (with clips) (glue and nail) 4. Rough Hardware: 1. Framing Members: quality: Contractor to submit steel shop drawings to designer or a licensed structural Construction and shall be detailed by a qualified structural steel detailer. B. All steel connections shall be designed according to AISC Manual of Steel engineer prior to steel erection. C. Architect will not be responsible for any errors in the roof and/or floor framing without the opportunity to review the roof and/or floor framing layouts. Framing layouts, member sizes, and floor/roof penetrations indicated on the drawings are for design intent only. Final layouts shall be the responsibility of builder. exterior applications. Unless noted otherwise, fasten multiple beams together exterior wall below. And as shown on the roof plan. A. This set of construction drawings is intended for design intent only. Although many jurisdictions will accept these drawings as sufficient for a construction permit, these drawings are not intended, and should not be construed, as a complete set of construction drawings. These drawings will have to be adapted to meet local zoning and/or site conditions and additional detailing will need to be completed on site by the builder. B. Install prefabricated fireplace units as shown on Drawings. 1. Fireplace units shall be "Heat -N-Glo" or as approved by Owner. 2. Contractor shall be responsible for proper installation as recommended by the manufacturer and as required by governing codes, including mantel and hearth design and location. C. Room sizes shown on the plans indicate room dimensions prior to installation of gypsum wall board. Gypsum wall board thickness must be subtracted from room sizes indicated for actual room dimensions and are subject to change. 2. Use exterior grade Micro-Lam in all areas subject to moisture. 3. Hearth shall be of non-combustible material. EARTH RIGID INSULATION CONCRETE BLOCK CONCRETE BRICK PLYWOOD STEEL OR STEEL STUD WALL BATT INSULATION GYPSUM BOARD GRAVEL WOOD OR WOOD STUD WALL SOUND INSULATION IN WALL MIN. (3) 2X SOLID BLOCKING BEARING WALL MATERIALS ELEVATION DRAWING NUMBER WALL TYPE SHEET NUMBER SHEET NUMBER SECTION DRAWING NUMBER DETAIL DRAWING NUMBER SHEET NUMBER POINT LOAD FROM ABOVE ELEVATION HEIGHT ELEVATION TYPE W2 SYMBOLS VINTAGE COOP PLAN INFORMATION PLAN OPTION: FOUNDATION: ROOF TRUSS: MONTEREY ESTATE SLAB ON GRADE UPPER FLOOR BONUS ROOM FULL BASEMENT STANDARD ROOF TRUSSES 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : IS S U E D F O R : 11 - 2 3 - 2 0 FO R C O N S T R U C T I O N 11 - 3 0 - 2 0 RE V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 RE V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 OW N E R R E Q U E S T E D C H A N G E S A0 19-137.2 3-18-2021 MS P L A N LR KC VI N T A G E E S T A T E S - N O R T H L I B E R T Y MO N T E R E Y E S T A T E V 2 TI T L E S H E E T SHEET LIST Sheet Number Sheet Name A0 TITLE SHEET A100 FOUNDATION PLAN A101 MAIN FLOOR PLAN A200 ELEVATIONS A201 DETAILS AREA SCHEDULE Level Name Area MAIN FLOOR MAIN FLOOR 2010 SF MAIN FLOOR GARAGE 547 SF Grand total: 2 2557 SF NOTE: THIS DRAWING IS AN ARTISTIC INTERPRETATION OF THE GENERAL APPEARANCE OF THE DESIGN. IT IS NOT INTENDED TO BE AN EXACT RENDITION. MAIN FLOOR 0" T.O.F. -6" B.O.F. -4' -0" W3W2 ***VERIFY ALL CHANGES IN WALL ELEVATION ON SITE. MAINTAIN 42" MINIMUM FROST PROTECTION AT ALL TIMES ***ALL FOUNDATION STEP- DOWNS TO BE DETERMINED ON SITE AS GRADE ALLOWS DROP T.O.F. @ O.H.D.- VERIFY W/ GRADE 4' - 0 " 8" 1' - 0 " 3' - 0 " 8" 8" 8" W1 6" 3' - 6 " 8" 8" 1' - 4"1' - 4"1' - 4" 1' - 4" 10 " CF16W4 6" 3' - 6 " 8" 8" 1' - 4" MA I N T A I N 4 2 " M I N I M U M FR O S T P R O T E C T I O N A T A L L T I M E S NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL NOTE: STEP FOOTINGS DOWN AS GRADE REQUIRES. MAINTAIN MINIMUM FROST PROTECTION AT ALL TIMES. NOTE: STEP FOUNDATION DOWN AS GRADE REQUIRES. MAINTAIN 42" MINIMUM FROST PROTECTION ON ALL FOOTINGS NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL PATIO ABOVE NOTE: CHANGES IN FOOTING AND FOUNDATION WALL ELEVATIONS ARE FOR DESIGN INTENT ONLY. ACTUAL ELEVATIONS SHALL BE VERIFIED W/FINAL GRADE DURING CONSTRUCTION. MAINTAIN 42" MINIMUM FROST PROTECTION ON ALL FOOTINGS. STEP DOWN FOOTING @ O.H.D. STOOP ABOVE 2' - 10"16' - 4"2' - 10" 16' - 0"14' - 4"11' - 8" 42' - 0" 46 ' - 8 " 24 ' - 0 " 2' - 0 " 72 ' - 8 " 7' - 8 " 11 ' - 4 " 38 ' - 8 " 13 ' - 0 " 2' - 0 " 72 ' - 8 " 22' - 0"11' - 0"9' - 0" 42' - 0" W4 W4 W4 W1 W2 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W4 W2 W2 2' - 4 " 8' - 4 " 8"22' - 0"18' - 8" 12 ' - 4 " 2' - 0 " W3 TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL DOWEL STOOP SLAB TO FOUNDATION -VERIFY ALL CHANGES IN WALL ELEVATION ON SITE -MAINTAIN 42" MINIMUM FROST PROTECTION AT ALL TIMES POST P20 FOOTING F30 F24 CF16 1'-8'' 2'-6'' 2'-0'' 1'-4'' DIA 2'-6'' 2'-0'' CONT 4'-0'' 1'-0'' 1'-0'' 10'' (2) #4 CONT. #4 AT 12" O.C. E.W. #4 AT 12" O.C. E.W. (2) #4 CONT. -NOT ALL TYPES ARE USED F36 3'-0'' 3'-0'' 1'-0'' #4 AT 12" O.C. E.W. 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A100 19-137.2 3-18-2021 MS P L A N ML K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y MO N T E R E Y E S T A T E V 2 FO U N D A T I O N P L A N SCALE: 1/4" = 1'-0"2 FOOTING LEGEND SCALE: 1/4" = 1'-0"1 FOUNDATION PLAN FOUNDATION SCHEDULE Type Mark WALL FOOTING Width Unconnected Height Hotizontal Reinforcements Vertical Reinforcements Footing Width Footing Length Footing Depth Footing Reinforcing W1 8" 3' - 6" #4 @ TOP & BOT. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. W2 8" 4' - 0" #4 @ TOP & BOT. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. W3 8" 3' - 0" #4 @ TOP & BOT. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. W4 8" 3' - 6" #4 @ TOP & BOT. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. DW DW A2004 A200 A200 A200 2 3 1 3' - 0"16' - 0"3' - 0"11' - 0"9' - 0" 42' - 0" BEDROOM 1 BEDROOM 2 LIVING ROOM KITCHEN MASTER BEDROOM M. BATH PANTRY 3/ 0 X 6 / 8 BA R N D O O R LAUNDRY M. CLOSET BATH FOYER MUD COVERED PORCH OPTIONAL PATIO DINING R/ S 72 ' - 8 " 5' - 6"5' - 6"6' - 9"2' - 3" 2' - 0 " 13 ' - 0 " 38 ' - 8 " 11 ' - 4 " 7' - 8 " 72 ' - 8 " TWO CAR GARAGE CLOSET 2 3/0 x 6/8 2/ 1 0 x 6 / 8 W. C . 2/6 x 6/8 3/0 x 6/8 2/ 1 0 x 6 / 8 2/ 1 0 x 6 / 8 2/10 x 6/8 2/10 x 6/8 2/ 1 0 x 6 / 8 2/10 x 6/8 PCKT 3/ 0 x 6 / 8 72 8 2 S L D R 5359 FXD 2959 CSMT 29 2 9 T R S M 29 2 9 T R S M 8' - 0"8' - 0"6' - 9 1/2"7' - 6 1/2"6' - 8"5' - 0" 16' - 0"14' - 4"11' - 8" 5359 FXD2959 CSMT 2959 CSMT 29 5 9 C S M T 2959 CSMT 2959 CSMT 29 4 7 C S M T 2- 2/ 6 x 6 / 8 29 2 9 T R S M 2935 CSMT 2959 CSMT3- 16/0 X 8/0 O.H.D. W.C. O.H.C. O. H . C . O. H . C . 29 1 7 F X D 42' - 0" 2' - 6 " 5' - 2 " 4' - 9 " 6' - 7 " 15 ' - 9 " 6" 24 ' - 0 " 9' - 4 " 5' - 2 " 4' - 1 0 " 5' - 2 " 2' - 5 1 / 2 " 4' - 4 1 / 2 " 14 ' - 4 " 6" 6" 13 ' - 7 " 4' - 1 0 1 / 2 " 2' - 0 1 / 2 " 4' - 4 " 1' - 2 " 7' - 8 " 3 1 / 2 " 1' - 1 0 1 / 2 " 16 ' - 1 0 " 6" 10 ' - 1 0 " 6" 6/ 0 x 6 / 8 GIRDER TRUSS ABOVE 6" 21' - 6" 6" 2' - 6"5' - 2 1/2"5' - 6"5' - 9 1/2" 6" 6" 7' - 6"5' - 4"2' - 2"14' - 8 1/2"11' - 3 1/2"6" 6" 6' - 3"4' - 4 1/2"4' - 4 1/2" 3 1/2" 14' - 0 1/2" 6" 2' - 0 " 24 ' - 0 " 46 ' - 8 " 2' - 6 " 10 ' - 4 " 4' - 7 " 7' - 3 1 / 2 " 14 ' - 1 1 / 2 " 7' - 4 " 6" EQ EQ O. H . C . R/ S 32X60 TUB/SHWR VA U L T E D VA U L T E D NOTE: WALLS AND CEILING TO BE FINISHED W/ 5/8" TYPE "X" FIRE CODE GYPSUM BOARD LINE OF O.H.D. IN OPEN POSITION GIRDER TRUSS ABOVE LO C K E R S MECH D W 3/ 0 x 6 / 8 NOTE: DIMENSIONS AND ROOM SIZES ARE SHOWN FOR DESIGN PURPOSES ONLY. DUE TO CONSTRUCTION MEANS, METHODS AND TOLERANCES, ROOM SIZES ARE SUBECT TO CHANGE WITHOUT NOTICE. 6"7' - 6"2' - 6 1/2"4' - 11 1/2"9' - 6"5' - 2 1/2"11' - 3 1/2" 6" 6' - 8 " 4' - 4 1 / 2 " 12 ' - 5 1 / 2 " 6' - 6 1 / 2 " 7' - 1 1 1 / 2 " 6" 11'-2" PEAK 2/ 1 0 X 6 / 8 O P E N I N G RA N G E RE F 2' - 0" HB HB POCKET DOOR OPTIONAL POCKET DOOR NICHE OPTIONAL 12" TRAY 12" TRAY CLG. 12" TRAY CLG. FURN WH COVERED PORCH 2 A201 Sim 3 A201 Sim SHELVES 29 1 7 F X D 8' - 6 " H . H . 8' - 6 " H . H . 2959 CSMT2- GL A S S 5' - 1 0 " 1' - 0 " 10' - 0" A101 3 PLUMB WALL AS REQ'D 1' - 0" 3/ 6 X 6 / 8 OP E N I N G SL O P E S L A B 6 " T O OV E R H E A D D O O R 0'-0" -0'-2" 2/6 x 6/8 9' - 2 1 / 2 " 4' - 1 0 " 3/ 0 x 6 / 8 F.D. ATTIC ACCESS ABOVE 135.00° 2/6 x 6/8 CLOSET 1 5' - 8"1' - 8 3/4" CL 1 CL 2 A101 4 29 5 9 C S M T 53 5 9 F X D 29 5 9 C S M T 8' - 1 1 " 14 ' - 0 " (2) 1 3/4x11 7/8 LVL HDR (2) 1 3/4x11 7/8 LVL HDR MA K E U P LA V LA V . L A V . A201 6 5 7A201 A2019 A201 10 A20111O. H . C . 3' - 4" 8' - 4 " SI N K ROOF NOTES: 2'-0" EAVE OVERHANG*** 1' - 6" GABLE RAKES*** 10:12 SLOPE SIDE TO SIDE*** 6:12 SLOPE FRONT TO BACK*** ***UNLESS NOTED OTHERWISE PROVIDE RIDGE, HIP AND SOFFIT VENTING TO COMPLY W/ GOVERNING CODES SNOW AND ICE BARRIER ALONG ALL EAVES & RAKES 2' - 0" PAST OUTSIDE FACE OF FRAMING (TYPICAL @ ALL EXTERIOR EAVES) OUTSIDE FACE OF FRAMING BELOW 4 1 / 2 " / 1 2 " 4 1 / 2 " / 1 2 " 10" / 12"10" / 12" 1' - 6"1' - 6" 2' - 0 " 1' - 6" 2' - 0 " 2' - 0 " 1' - 6" 2' - 0 " RIDGE V ALLEY V A L L E Y RI D G E RI D G E RI D G E VALLEYV A L L E Y 2' - 0 " 2' - 0"2' - 0" 10" / 12"10" / 12" V ALLEY V A L L E Y RI D G E 10" / 12"10" / 12" 2' - 0 " DR O P Z O N E O. H . C . LO C K E R S GL A S S RA N G E MUD 3/ 0 X 6 / 8 BA R N D O O R 2/4 x 6/8 PANTRY 3/ 0 x 6 / 8 2/ 1 0 x 6 / 8 3/0 x 6/8 A2018 SI M 29 5 9 C S M T 29 5 9 C S M T 2959 CSMT VA U L T E D VA U L T E D 11'-2" PEAK OP T . FP 2' - 1 0 1 / 2 " 2' - 1 0 1 / 2 " 5' - 4 " 2' - 1 0 1 / 2 " 2' - 1 0 1 / 2 " LIVING ROOM 2- RE F RA N G E 12 ' - 1 " 3' - 3"3' - 0"3' - 3" 9' - 6" 1' - 1 " 1' - 0 " 2' - 1 " 8' - 4 " O.H.C. MW HO O D SI N K 2' - 6 " 2' - 6 " 1' - 6 " 1' - 3 " 1' - 3 " 1/ 2 " 3' - 0 " 1/ 2 " O.H.C. O.H.C. O. H . C . O . H . C . O . H . C . O. H . C . 3' - 4" 1" 1" 2' - 0 " 3' - 0 " 1' - 6 " 1' - 6 " 1" 1" 3/4"2' - 0"1' - 3 1/4" A201 6 5 7A201 1' - 10 1/2" 1' - 10 1/2" 1' - 6 " 1' - 6 " 3' - 0 " 1" 4' - 0 " 3' - 3 1 / 2 " 4' - 0 " 1" 12 ' - 0 " MA K E U P 1' - 10 1/2" 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A101 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y MO N T E R E Y E S T A T E V 2 MA I N F L O O R P L A N SCALE: 1/4" = 1'-0"1 MAIN FLOOR PLAN SCALE: 1/4" = 1'-0"2 ROOF PLAN SCALE: 1/4" = 1'-0"3 MUD/PANTRY - OPTION B SCALE: 1/4" = 1'-0"4 FIREPLACE OPTION SCALE: 1/4" = 1'-0"5 MONTEREY KITCHEN SCALE: 1/4" = 1'-0"6 MONTEREY BATH SCALE: 1/4" = 1'-0"7 MONTEREY MASTER BATH MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MAIN WIN. H.H. 6' -10" T.O.F. -6" R1 M1 S1 C1 L1 S3 F1 2525 TRSM 2525 TRSM 2525 TRSM 2525 TRSM 9' - 1 1 / 8 " T4 M2 T5 T7 F1 CONCRETE - SLOPE TO GRADE T7 S3 T4 F1 R1 F1 S3 T4 T7 F1 T5 T2 L1 S1 M2 M1 R1 F1 S1 T1 T2T2 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE C1 M2 M1 T5 R1 F1 T1 S1 M1 M2 L1 T2 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE S1 T1 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE C1 M1 M2 FIREPLACE OPTION B WINDOW LOCATIONS 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A200 19-137.2 3-18-2021 MS P L A N ML K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y MO N T E R E Y E S T A T E V 2 EL E V A T I O N S SCALE: 1/4" = 1'-0"1 FRONT SCALE: 1/4" = 1'-0"2 BACK SCALE: 1/8" = 1'-0"3 LEFT SCALE: 1/8" = 1'-0"4 RIGHT Keynote Legend Key Value Keynote Text C1 COLUMN WRAP - OR - TRIM OUT COLUMN F1 6" ALUMINUM FASCIA OR 6" ALUMINUM RAKE L1 EXTERIOR WALL LIGHT M1 MASONRY- CULTURED STONE M2 MASONRY- STONE CAP R1 LAMINATED ASPHALT ROOF SHINGLES S1 (LAP SIDING) HARDIE-PLANK SIDING-7" MAX EXPOSURE S3 (BOARD AND BATTEN SIDING) VERTICAL SIDING AND HARDIE TRIM T1 PAINTED HARDIE CORNER TRIM T2 4" PAINTED TRIM T4 6" OVER 8" PAINTED TRIM T5 7" OVER 12" PAINTED TRIM T7 4" TRIM AT WINDOWS ON FRONT ELEVATION ONLY 1X3 BATTENS ON SMOOTH PANEL SIDING SEE ROOF PLAN 36" PLASTIC ATTIC CHUTE SNOW AND ICE BARRIER EXTEND 24" PAST I.S. FACE OF EXTERIOR WALLS LAMINATED ASPHALT ROOF SHINGLES ON 30# ROOF FELT ON 1/2" O.S.B. SHEATHING MTL. DRIP 8" FASCIA 2X6 SUB-FASCIA 3/8" VENTED HARDI- SOFFIT ON 2X4 LOOKOUTS @ 24" O.C. 8" TRIM ON 8" TRIM SEE ELEVATIONS FOR SIDING MATERIAL WEATHER RESISTANT BARRIER OVER 1/2" O.S.B. SHEATHING ON 2X6 WALL STUDS @16" O.C. R20 INSULATION 1/2" GYP. BD. ON 6MIL POLY VAPOR BARRIER FLASHING (ALL HORIZ. JOINTS) 2X6 SILL PLATE "TRTD" ON CLOSED CELL FOAM SILL SEALER 4" PERF. DRAIN WILE W/ SILT SLEEVE R49 BLOWN INSULATION 12 SE E R O O F PL A N MAIN FLOOR 12 " E N E R G Y H E E L M I N . 6" 2" T.O.F. 0'-0" 0'-4" FOUNDATION WALL-REFER TO PLAN TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL MAIN FLOOR PLT. HT. 9'-1 1/8" HOLD ALL TRIM AND SIDING MIN. 6" ABOVE GRADE 9' - 1 1 / 8 " CONTINUOUS BEAD OF SEALANT 4"4" 4' - 0 " LINE OF GRADE (VARIES) 2" 4" 2' - 0" MAIN FLOOR 0'-0" TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL CONTINUOUS BEAD OF SEALANT 4"4" 2" 4" 2' - 0"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE GARAGE SLAB (SLOPE TO OVERHEAD DOOR) MAIN FLOOR 0'-0" TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL CONTINUOUS BEAD OF SEALANT 4"4" 2" 2' - 0"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE SLAB (SLOPE AWAY FROM HOUSE) MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 2' - 1 0 1 / 2 " 1 1 / 2 " 1' - 6 " 3' - 0 " 7' - 6 " 2' - 6"2' - 6 1/2"1' - 6"1' - 3"1' - 3"3' - 0 1/2" 12' - 1" 2' - 6"2' - 6"1' - 6"1' - 3"1' - 3" 1/2" 3' - 0" 1' - 6 " 6' - 0 " 7' - 6 " REF. MW HOOD RANGE 12' - 1" MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 3' - 3"3' - 0"3' - 3" 9' - 6" 2' - 1 0 1 / 2 " 1 1 / 2 " 1' - 6 " 3' - 0 " 7' - 6 " 3' - 3"3' - 0"3' - 3" 9' - 6" MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 1"2' - 0"3' - 0"1' - 6"1' - 6"1" 8' - 2" 2' - 1 0 1 / 2 " 1 1 / 2 " 3' - 0 " DW MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 2' - 1 0 1 / 2 " 1 1 / 2 " 1' - 6 " 3' - 0 " 7' - 6 " REF. MW HOOD RANGE PANTRY 1' - 9"2' - 6 1/2"1' - 6" 5' - 9 1/2" 6' - 0 " 1' - 6 " 7' - 6 " 1' - 9"2' - 6"1' - 6"3' - 0" 8' - 9" MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 1"4' - 0"3' - 3 1/2"4' - 0"1" 11' - 5 1/2" 2' - 1 0 1 / 2 " 1 1 / 2 " 3' - 0 " MAKEUP 1 1 / 2 " 2' - 4 1 / 2 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 3' - 0" 2' - 1 0 1 / 2 " 1 1 / 2 " 3' - 0 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 4' - 6 " 3' - 0 " 7' - 6 " 2' - 6"2' - 6" 5' - 0" W/D 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A201 19-137.2 3-18-2021 MS P L A N ML K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y MO N T E R E Y E S T A T E V 2 DE T A I L S WINDOW SCHEDULE From Room: Name Type Comments BATH 2935 CSMT E3 DINING 2959 CSMT E DINING 5359 FXD DINING 2959 CSMT E M. BATH 2917 FXD LIVING ROOM 2959 CSMT E BEDROOM 1 2959 CSMT E BEDROOM 1 2959 CSMT E BEDROOM 1 2959 CSMT E BEDROOM 2 2947 CSMT E BEDROOM 2 2947 CSMT E MASTER BEDROOM 2959 CSMT E MASTER BEDROOM 5359 FXD MASTER BEDROOM 2959 CSMT E LAUNDRY 2929 TRSM MASTER BEDROOM 2929 TRSM MASTER BEDROOM 2959 CSMT E MASTER BEDROOM 2929 TRSM 2525 TRSM GABLE 2525 TRSM GABLE 2525 TRSM GABLE 2525 TRSM GABLE 2917 FXD LIVING ROOM 2959 CSMT E LIVING ROOM 2959 CSMT E 2959 CSMT E LIVING ROOM 2959 CSMT E 5359 FXD LIVING ROOM 2959 CSMT E Grand total: 29 DOOR SCHEDULE Level Type To Room: Name Door CommentsWidth Height Material Finish MAIN FLOOR 2/4 x 6/8 2' - 4" 6' - 8" MAIN FLOOR 2/10 x 6/8 BATH 2' - 10" 6' - 8" MAIN FLOOR 2/10 x 6/8 BEDROOM 1 2' - 10" 6' - 8" MAIN FLOOR 3/0 x 6/8 BEDROOM 2 3' - 0" 6' - 8" MAIN FLOOR 2/6 x 6/8 CLOSET 1 2' - 6" 6' - 8" MAIN FLOOR 2/6 x 6/8 CLOSET 2 2' - 6" 6' - 8" MAIN FLOOR 7282 SLDR DINING 6' - 0" 6' - 10" MAIN FLOOR 3/0 x 6/8 FOYER 3' - 0" 6' - 8" MAIN FLOOR 6/0 x 6/8 FOYER 6' - 0" 6' - 8" MAIN FLOOR 2/10 x 6/8 LAUNDRY 2' - 10" 6' - 8" MAIN FLOOR 2/10 x 6/8 PCKT 2 M. BATH 2' - 10" 6' - 8" MAIN FLOOR 2/10 x 6/8 M. BATH 2' - 10" 6' - 8" MAIN FLOOR 2/10 x 6/8 M. CLOSET 2' - 10" 6' - 8" MAIN FLOOR 2/10 x 6/8 M. CLOSET 2' - 10" 6' - 8" MAIN FLOOR 3/0 x 6/8 MASTER BEDROOM 3' - 0" 6' - 8" MAIN FLOOR 3/0 x 6/8 MECH 3' - 0" 6' - 8" MAIN FLOOR 3/0 x 6/8 MUD 3' - 0" 6' - 8" MAIN FLOOR 34" x 80" MUD 0" 0" MAIN FLOOR 2/6 x 6/8 MUD 2' - 6" 6' - 8" MAIN FLOOR 2/6 x 6/8 PANTRY 2' - 6" 6' - 8" T.O.F. 16'-0" x 8'-0" TWO CAR GARAGE 16' - 0" 8' - 0" NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL DOORS PRIOR TO BIDDING AND CONSTRUCTION NOTE: VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL WINDOWS PRIOR TO BIDDING AND CONSTRUCTION NOTE: VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION NOTE: GLASS SHOWER DOORS NOT INCLUDED IN SCHEDULE ROOM FINISH SCHEDULE- OVERALL ROOM NO ROOM NAME AREA FLOOR BASE WALLS CEILING NOTESN E S W FINISH HEIGHT 35 BEDROOM 1 130 SF CARPET 36 BEDROOM 2 118 SF CARPET 37 LIVING ROOM 195 SF LVP 38 KITCHEN 277 SF LVP 39 MASTER BEDROOM 215 SF CARPET 40 M. BATH 136 SF LVT 41 PANTRY 23 SF LVP 42 LAUNDRY 67 SF LVP 43 M. CLOSET 72 SF CARPET 45 BATH 50 SF LVT 46 FOYER 133 SF LVP 47 MUD 89 SF LVP 48 DINING 160 SF LVP 49 TWO CAR GARAGE 506 SF CONCRETE 50 CLOSET 2 20 SF CARPET 52 MECH 71 SF CONCRETE 53 CLOSET 1 21 SF CARPET 54 CL 1 18 SF LVP 55 CL 2 10 SF LVP NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL FINISHES PRIOR TO BIDDING AND CONSTRUCTION NOTE: VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION SCALE: 1/2" = 1'-0"1 TYPICAL WALL SECTION SCALE: 1" = 1'-0"2 TYP. ZERO ENTRY DETAIL - GARAGE SCALE: 1" = 1'-0"3 TYP. ZERO ENTRY DETAIL - STOOP SCALE: 1" = 1'-0"4 TERMITE GUARD SCALE: 1/4" = 1'-0"5 KITCHEN ELEVATION 1 SCALE: 1/4" = 1'-0"6 KITCHEN ELEVATION 2 SCALE: 1/4" = 1'-0"7 KITCHEN ISLAND ELEVATION SCALE: 1/4" = 1'-0"8 KITCHEN ELEVATION - OPTION B SCALE: 1/4" = 1'-0"9 MASTER BATH ELEVATION SCALE: 1/4" = 1'-0"10 BATH ELEVATION SCALE: 1/4" = 1'-0"11 LAUNDRY ELEVATION GENERAL NOTES B. Submit floor truss layouts showing beam locations, joist layout, locations of continuous duct chases, and maximum duct size in each chase. Allow designer five days for complete review. lumber package. Allow designer five days for complete review. manufacturer for review prior to ordering roof trusses and/or roof A. Submit roof truss and/or rafter layout plan as completed by the 12. SUBMITTALS 8. DOORS AND WINDOWS A. Exterior doors shall be selected by the Owner. B. House-to-garage doors shall be fire rated doors approved by governing codes. Face design to be selected by the Owner. C. Interior doors shall be selected by the Owner. D. Exterior windows by Pella Corp as selected by owner. E. Glazing in all doors and windows shall comply with governing codes. F. Install egress window units in accordance with governing codes. G. Door and window sizes indicated or drawings are as follows: "3/0x6/8" represents a door or window 3'-0" wide x 6'-8" high. Jamb depth to be coordinated by the Contractor. H. Finish hardware shall be selected by the owner. Install hardware in accordance with governing codes. 9. FINISHES A. Gypsum wallboard, unless noted otherwise, shall be provided as follows: 1. Exterior walls: One layer 1/2" regular wallboard to interior face. 2. Interior walls: One layer 1/2" regular wallboard each face. 3. Ceiling: One layer 5/8" regular wallboard. 4. Garage/House common wall: One layer 5/8" type "X" wallboard each face. 5. Baths: Water resistant wallboard at all walls and ceilings surrounding tubs and showers and as required by governing codes. Provide cement board as substrate for ceramic tile. B. Provide metal corner bead and trim at all locations recommended by the gypsum wallboard manufacturer. C. Tape, float, and sand joints and fasteners of gypsum wallboard with three coats of joint compound as required to obtain a uniformly smooth surface. D. Finishes shall be selected by the Owner. 10. PLUMBING, MECHANICAL, AND ELECTRICAL A. Plumbing, mechanical, and electrical information and layouts shown on the Drawings is schematic in design, and shall be reviewed by sub-contractors, suppliers, and building officials for compliance with governing codes and good common construction practices. The Architect shall be notified by the Contractor of any discrepancies prior to construction. B. Plumbing, mechanical, and electrical equipment shall be selected by the Owner. C. Design and installation of plumbing, mechanical, and electrical equipment shall be the responsibility of the appropriate licensed contractors and sub- contractors. Design shall be submitted for owner's review prior to ordering D. Service panels shall be selected by the electrical sub-contractor. E. All HVAC equipment shall be individually switched. F. All outdoor, bath, and garage and spa wall receptacles shall be provided with ground fault circuit protection in accordance with governing codes. G. Dryer vents shall be extended to the exterior. H. Provide plumbing vents in accordance with governing codes. Minimize number and locate for minimal visual impact. I. Install type and number of smoke detectors in accordance with governing codes & UL217. J. Connect water, gas, and electric services in accordance with governing codes. 11. MISCELLANEOUS and installation of equipment. exterior walls install plates over foam sill sealer. C. Unless noted otherwise, all slabs on grade shall be 4" thick, reinforced with 6x6 W1.4xW1.4 W.W.M., and placed over 4" minimum compacted sand or gravel fill. Interior slabs shall be placed over 6 mil. Stabilized polyethylene vapor barrier. Coordinate with radon removal procedures. D. Footing sizes shown are typical only for stated soil pressure and consistent compaction. Contractor shall be responsible for footings complying with A. Adhered masonry flashing must be installed at wall penetrations and terminations integrated with the WRB properly (when used), and installed in accordance with the to ensure a consistent overall project color on the wall. C. Install in accordance with manufacturer's installation instructions. Visit this page for http://ncmabr.org/pdfs/masterlibrary/MVMA%20Installation%20Guide%204th%20Edition%20web.pdf Consult manufacturer for proper installation instructions. modified mortar meeting ANSI A118.4 OR ANSI 118.15. F. Touch-up, repair or replace damaged stone before completion of project. A. All structural steel shall comply with appropriate ASTM Specifications as follows: ASTM A36, ASTM A53, ASTM A501, ASTM A307, and ASTM A. Lumber shall, in addition to complying with governing codes, comply with: 1. "Product Use Manual" of the Western Wood Products Association for selection and use of products included in that manual. 2. "Plywood Specification and Grade Guide" of the American Plywood 3. "Standard Specifications for Grades of California Redwood Lumber" of 4. American Wood Preservers Association standards and recommendations for fire-retardate and preservative pressure treated lumber and plywood. 5. Western Red Cedar Lumber Association standards and recommendations the Redwood Inspection Bureau for Redwood. for cedar. Association. D. Application details and mortar recommendations may vary depending on the stone style. E. All dry-stacked and large format standard stones must be applied using a polymer - 5. METALS A325. 6. WOOD AND PLASTICS the design requirements of specific soil conditions. of the stone veneer. Assure that all flashing and kickouts are corrosion resistant, local building code requirements. B. Product should be pulled from a variety of boxes and blended on site during intalllation installation instructions: 4. MASONRY Install skylights according to the manufactures' recommendations. I. Install water and ice barrier (Bituthene or equal) over roof sheathing at all eaves and valleys. water & ice barrier to extend 24" past outside face of L. Provide 2" nominal pressure treated lumber over foam sill sealer beneath full bearing of wood beams bearing on concrete or 7. THERMAL AND MOISTURE PROTECTION A. Provide thermal building insulation at assemblies adjacent to exterior or unheated spaces meeting the requirements of governing codes and, unless noted otherwise, meeting the following minimum requirements: 1. Foundations: 1 1/2"extruded polystyrene (R-10) 2. Walls: glass fiber batt (R-20) U.N.O. 3. Floors: glass fiber batt (R-30) -for floors over unconditioned space or exterior 4. Ceilings: glass fiber batt (R-49) 5. Install continuous blankets without holes for electrical boxes, lighting fixtures, or heating ductwork. B. Install 6 mil. stabilized polyethylene vapor barrier against interior face of all C. Waterproof foundation walls at excavated areas from footing to finished grade with two coats of asphalt based waterproofing compound for full basements. D. Roofing shall be 240 lb. (minimum) composition shingles installed over 15 lb. roof felt on roof sheathing. Minimum slope, fasteners, under layment, and exposure according to manufacturers' recommendations. E. Provide flashing and sheet metal required to prevent penetration of water through the exterior shell of the building. In addition to complying with governing codes, comply with pertinent recommendations contained in the current edition of "Architectural Sheet Metal Manual" published by SMCNA. All iron sheet metal flashing shall be hot-dipped galvanized complying with F. Provide gutters and downspouts to provide positive roof and site drainage. G. Provide attic and roof ventilation as required by governing codes and as shown on the Drawings. Provide appropriate soffit and roof vents. H. Skylights shall be selected by the Contractor and approved by the owner. ASTM A93. thermal insulation. masonry. 1. Before final Drawings and Specifications are issued for construction, they shall be submitted to all governing building agencies to insure their compliance with all applicable local and national codes. If code discrepancies in Drawings and/or Specifications appear, the Architect shall be notified of such discrepancies in writing by the Contractor or building official, and allowed to alter the drawings and specifications so as to comply with governing codes before construction begins. 2. Upon written receipt of approval from the governing official, approved final Drawings and Specifications shall be submitted to the Contractor by 3. If code discrepancies are discovered during the construction process, the Architect shall be notified and allowed ample time to remedy said 4. All work performed shall comply with all applicable local, state and national building codes, ordinances and regulations, and all other B. All contractors, suppliers, and fabricators shall be responsible for the content of the Drawings, and for the supply and design of appropriate C. All manufactured articles, materials, and equipment shall be handled, applied, installed, erected, used, cleaned, and conditioned in strict accordance with the D. All alternates are at the option of the Owner and shall be at the Owner's request, constructed in addition to or in lieu of the typical construction, as dead load 15psf (10 psf top, 5psf bottom) dead load 15psf (10 psf top, 5psf bottom) 5. Prior to start of construction, verify design loads with governing codes and site conditions. Check with local building agencies for wind, seismic, snow and other special loading conditions. If discrepancies are discovered, Architect shall be notified according to Section 1.A.1 above. A. Perform excavation, according to good common construction practices, to the lines, grades, and elevations indicated on the Drawings. B. Provide consistent compaction of the top 8" of sub-grade, fill, and backfill material beneath structures, walks, and pavements to meet the stated soil C. Provide soil poisoning to control termites as required by governing codes. D. Provide and install ventilation for Radon Gas as required by local building A. Provide concrete complying with ASTM C94. Unless otherwise noted, concrete shall have the following 28 day compressive strengths as minimums: 2. Concrete floor slabs, walks, drives, and patios: 3,500psi 3. Provide construction joints so panel size does not exceed 400sf. B. Provide reinforcement of the size and spacing indicated on Drawings. Reinforcing shall comply with the following minimums: live load 60psf (maximum) live load 40psf (maximum) live load 30psf (maximum) agencies and governing codes. 1. Concrete footings and foundations: 3,000psi 1. Bars: ASTM A615, grade 40, deformed bars. 2. Welded Wire Fabric: ASTM A185. 3. CONCRETE 2. SITE WORK pressure. materials and work performance. manufacturers' requirements. indicated on the Drawings. 3. Balconies and Decks: 4. Soil Pressure: 1500 psf (minimum) 2. Floor: 1. Roof: E. Design Loads: dead load 10psf 1. GENERAL REQUIREMENTS authorities having jurisdiction. discrepancies. the Architect. A. Codes: drawings to designer for review prior to construction. spacing of all trusses. Contractor to submit truss drawings and/or roof framing b. Install joist and beam hangers capable of supporting the maximum allowable load of joist or beam being supported. C. Provide "Micro-Lam" glue laminated veneer lumber beams (manufactured by Truss Joist Corporation) or equal, of the dimensions and number indicated on the drawings. Provide exterior grade Micro Lams for deck framing and other in strict accordance with manufacturers' recommendations. a. Modulus of elasticity: 2,000,000 psi b. Flexural (12" depth): 2,900 psi c. Horizontal shear: 285 psi D. Provide wood trusses able to sustain the stated loads for the spans, profiles, and arrangement shown on the Drawings. Truss layout is schematic only. Truss manufacturer and/or engineer shall be responsible for the design and E. All roof trusses shall be installed with metal truss seats as specified by the F. Unless noted otherwise, provide: 1. Double header joists and trimmers at all floor openings. 2. Double joists under all partitions parallel to joists. 3. Double 2x12 headers with 1/2 OSB between at all door and window openings in 2x4 walls. Triple 2x10 headers with 1/2" OSB between at all door and window openings at 2x6 walls. 4. For solid sawn joists, provide one row of 1x3 cross -bridging or metal bridging G. Stud spacing at all exterior and bearing walls shall be 16" o.c. minimum. H. Stud walls shall not exceed the following heights without continuous lateral support perpendicular to the plane of the wall at the stated height or less. Studs shall be continuous between points of lateral support. I. Unless noted otherwise, rafters, ceiling joists, collar ties, and purlins shall be sized and spaced in accordance with FHA requirements or governing codes, J. Stair construction shall consist of (3)2x12 stringers, 5/4" or 2x thick tread and 3/4" thick risers or, shall be fabricated by component manufacturer. K. All wood plates bearing on concrete or masonry shall be pressure treated. At b. 2x6: 12'-0' 2. Non-bearing walls: a. 2x4: 14'-0" b. 2x6: 20'-0" whichever is more restrictive. 1. Bearing walls: a. 2x4: 10'-0" for each 8'-0" of joist span. d. Bearing: 550 psi truss manufacturer. 1. Allowable stresses: B. Provide lumber and materials meeting or exceeding the following standards of a. Studs: Douglas Fir-Larch, Stud Grade -or as approved by building code. b. Headers and Beams: Douglas Fir-Larch, No. 2 and better -or as appoved by building code. 2. All headers and beams shall be free from splits, checks, and shakes. a. Roof: 1/2" OSB APA RATED SHEATHING, EXP 1. b. Walls: 1/2" OR 7/16" OSB APA RATED SHEATHING, EXP 1. c. Floor: 23/32" plywood APA RATED SHEATHING, EXP 1. d. Proper oriented strand board may be substituted for plywood. steel at exterior locations. a. Steel items: Comply with ASTM A36; use galvanized 3. Sheathing: (with clips) (glue and nail) 4. Rough Hardware: 1. Framing Members: quality: Contractor to submit steel shop drawings to designer or a licensed structural Construction and shall be detailed by a qualified structural steel detailer. B. All steel connections shall be designed according to AISC Manual of Steel engineer prior to steel erection. C. Architect will not be responsible for any errors in the roof and/or floor framing without the opportunity to review the roof and/or floor framing layouts. Framing layouts, member sizes, and floor/roof penetrations indicated on the drawings are for design intent only. Final layouts shall be the responsibility of builder. exterior applications. Unless noted otherwise, fasten multiple beams together exterior wall below. And as shown on the roof plan. A. This set of construction drawings is intended for design intent only. Although many jurisdictions will accept these drawings as sufficient for a construction permit, these drawings are not intended, and should not be construed, as a complete set of construction drawings. These drawings will have to be adapted to meet local zoning and/or site conditions and additional detailing will need to be completed on site by the builder. B. Install prefabricated fireplace units as shown on Drawings. 1. Fireplace units shall be "Heat-N-Glo" or as approved by Owner. 2. Contractor shall be responsible for proper installation as recommended by the manufacturer and as required by governing codes, including mantel and hearth design and location. C. Room sizes shown on the plans indicate room dimensions prior to installation of gypsum wall board. Gypsum wall board thickness must be subtracted from room sizes indicated for actual room dimensions and are subject to change. 2. Use exterior grade Micro-Lam in all areas subject to moisture. 3. Hearth shall be of non-combustible material. E. All excavations located beneath interior floor slabs (including garage) shall be inspected by a geotechnical engineer for bearing and the presence of unsuitable soils. If unsuitable soils are identified, the contractor shall follow the recommendations of the geotechnical engineer. F. All excavations located beneath footings and foundations shall be inspected by a geotechnical engineer for bearing and the presence of unsuitable soils. If unsuitable soils are identified, the contractor shall follow the recommendations of the geotechnical engineer. EARTH RIGID INSULATION CONCRETE BLOCK CONCRETE BRICK PLYWOOD STEEL OR STEEL STUD WALL BATT INSULATION GYPSUM BOARD GRAVEL WOOD OR WOOD STUD WALL SOUND INSULATION IN WALL MIN. (3) 2X SOLID BLOCKING BEARING WALL MATERIALS ELEVATION DRAWING NUMBER WALL TYPE SHEET NUMBER SHEET NUMBER SECTION DRAWING NUMBER DETAIL DRAWING NUMBER SHEET NUMBER POINT LOAD FROM ABOVE ELEVATION HEIGHT ELEVATION TYPE W2 SYMBOLS VINTAGE COOP PLAN INFORMATION PLAN OPTION: FOUNDATION: ROOF TRUSS: NAPA ESTATE SLAB ON GRADE UPPER FLOOR BONUS ROOM FULL BASEMENT STANDARD ROOF TRUSSES 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : IS S U E D F O R : 11 - 2 3 - 2 0 FO R C O N S T R U C T I O N 11 - 3 0 - 2 0 RE V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 RE V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 OW N E R R E Q U E S T E D C H A N G E S A0 19-137.2 3-18-2021 MS P L A N LR KC VI N T A G E E S T A T E S - N O R T H L I B E R T Y NA P A E S T A T E P L A N TI T L E S H E E T SHEET LIST Sheet Number Sheet Name A0 TITLE SHEET A100 FOUNDATION PLAN A101 MAIN FLOOR PLAN A200 ELEVATIONS A201 DETAILS AREA SCHEDULE Level Name Area MAIN FLOOR MAIN FLOOR 1394 SF MAIN FLOOR GARAGE 560 SF Grand total: 2 1954 SF NOTE: THIS DRAWING IS AN ARTISTIC INTERPRETATION OF THE GENERAL APPEARANCE OF THE DESIGN. IT IS NOT INTENDED TO BE AN EXACT RENDITION. MAIN FLOOR 0" T.O.F. -6" B.O.F. -4' -0" W3W2 ***VERIFY ALL CHANGES IN WALL ELEVATION ON SITE. MAINTAIN 42" MINIMUM FROST PROTECTION AT ALL TIMES ***ALL FOUNDATION STEP- DOWNS TO BE DETERMINED ON SITE AS GRADE ALLOWS DROP T.O.F. @ O.H.D., VERIFY W/ GRADE 4' - 0 " 8" 6" 3' - 0 " 8" 8"8" 1' - 4"1' - 4" W1 6" 1' - 4" 3' - 6 " 8" CF 16 10 " 1' - 4" W4 0" 3' - 6 " 8" 8" 1' - 4"MA I N T A I N 4 2 " M I N . F R O S T PR O T E C T I O N A T A L L T I M E S 2' - 10"16' - 4"1' - 6"7' - 8"12' - 8" NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL NOTE: STEP FOOTINGS DOWN AS GRADE REQUIRES. MAINTAIN MINIMUM FROST PROTECTION AT ALL TIMES. NOTE: STEP FOUNDATION DOWN AS GRADE REQUIRES. MAINTAIN 42" MINIMUM FROST PROTECTION ON ALL FOOTINGS NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL STOOP ABOVE NOTE: CHANGES IN FOOTING AND FOUNDATION WALL ELEVATIONS ARE FOR DESIGN INTENT ONLY. ACTUAL ELEVATIONS SHALL BE VERIFIED W/FINAL GRADE DURING CONSTRUCTION. MAINTAIN 42" MINIMUM FROST PROTECTION ON ALL FOOTINGS. STEP DOWN FOOTING @ O.H.D. 4 A201 STOOP ABOVE 41' - 0" W2 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 7' - 0 " 25 ' - 4 " 29 ' - 0 " 5' - 8 " 67 ' - 0 " 9' - 0"13' - 0"19' - 0" 41' - 0" W4 W4 W4 W4 W4 W4 W4 W2 W3 W1 W1 8" 27' - 0" 8" 2' - 0"10' - 0" 8" 8"20' - 8" 8" 5' - 8"12' - 8"8" 2' - 0 " 5' - 0 " 7' - 0 " 27 ' - 0 " 11 ' - 8 " 14 ' - 4 " 67 ' - 0 " 8"8" 2' - 10"16' - 4"2' - 10" W2 W1 TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL DOWEL STOOP SLAB TO FOUNDATION 20' - 8"20' - 4" NOTE: CHANGES IN FOOTING AND FOUNDATION WALL ELEVATIONS ARE FOR DESIGN INTENT ONLY. ACTUAL ELEVATIONS SHALL BE VERIFIED W/FINAL GRADE DURING CONSTRUCTION. MAINTAIN 42" MINIMUM FROST PROTECTION ON ALL FOOTINGS. W1 2' - 0 " 9' - 0 " 135.00° -VERIFY ALL CHANGES IN WALL ELEVATION ON SITE -MAINTAIN 42" MINIMUM FROST PROTECTION AT ALL TIMES POST P20 FOOTING F30 F24 CF16 1'-8'' 2'-6'' 2'-0'' 1'-4'' DIA 2'-6'' 2'-0'' CONT 4'-0'' 1'-0'' 1'-0'' 10'' (2) #4 CONT. #4 AT 12" O.C. E.W. #4 AT 12" O.C. E.W. (2) #4 CONT. -NOT ALL TYPES ARE USED F36 3'-0'' 3'-0'' 1'-0'' #4 AT 12" O.C. E.W. 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A100 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y NA P A E S T A T E P L A N FO U N D A T I O N P L A N SCALE: 1/4" = 1'-0"2 FOOTING LEGEND SCALE: 1/4" = 1'-0"1 FOUNDATION PLAN FOUNDATION SCHEDULE Type Mark WALL FOOTING Width Unconnected Height Hotizontal Reinforcements Vertical Reinforcements Footing Width Footing Length Footing Depth Footing Reinforcing W1 8" 3' - 6" #4 @ TOP & BOT. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. W2 8" 4' - 0" #4 @ TOP & BOT. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. W3 8" 3' - 0" #4 @ TOP & BOT. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. W4 8" 3' - 6" #4 @ TOP & BOT. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. 4 A201 22' - 0"5' - 0"14' - 0" 14 ' - 4 " 11 ' - 8 " 13 ' - 6 " 5' - 4 1 / 2 " 4' - 3 " 10 ' - 1 0 1 / 2 " 4' - 6 " 2' - 0 " 6" 3' - 0"16' - 0"3' - 0"2' - 6"2' - 6"7' - 0"7' - 0" W.C. COVERED PORCH R/S R/ S R/ S MUD/LAUN. MASTER BEDROOM BATH GUEST BEDROOM TWO CAR GARAGE 41' - 0" M. BATH M. CLOSET OPTIONAL PATIO LOCKERS W.C. 67 ' - 0 " 3/0 x 6/8 PCKT 2/ 8 x 6 / 8 2/ 8 x 6 / 8 2/8 x 6/8 3/ 0 x 6 / 8 3/ 0 x 6 / 8 2/10 X 6/8 R/ S 2/ 1 0 X 6 / 8 3/ 0 X 6 / 8 KITCHEN DINING 3' - 9"5' - 3"13' - 0"6' - 4"12' - 8" 41' - 0" 7' - 0 " 25 ' - 4 " 5' - 7 " 2' - 2 1 / 2 " 8' - 8 " 6' - 0 1 / 2 " 6' - 6 " 5' - 8 " 67 ' - 0 " FOYER GUEST CLOSET COVERED PORCH PLUMBING WALL AS REQ'D FOR W/D HOOKUPS 29 3 5 C S M T 2959 CSMT 2959 CSMT 29 5 9 C S M T 1' - 1 0 " 4' - 8 " 5' - 8 " 6" 3' - 3"3' - 3"10' - 1 1/2"4' - 4 1/2"6' - 4"6" O.H.C. O. H . C . R/S 2' - 3"8' - 6"2' - 3" 2' - 0 " 4' - 6 " 5' - 2 " 9' - 2 " 5' - 2 " RO O F T R U S S A B V . @ 2 4 " O . C . G.T.A. G.T.A.EX. GRADE LVL BM ABOVE 3559 CSMT 2' - 11"3' - 5"2' - 0"5' - 0"5' - 8" 32 X 6 0 TU B / S H W R 72 8 2 S L D R 2/ 0 x 6 / 8 EX. GRADE LVL BM ABOVE (2) 1 3/4 X 11 7/8 LVL HEADER ATTIC ACCESS ABOVE ROOF TRUSS ABV. @ 24" O.C. ROOF TRUSS ABV. @ 24" O.C. EX. GRADE LVL BM ABOVE 2/ 1 0 X 6 / 8 RO O F T R U S S A B V . @ 2 4 " O . C . NOTE: WALLS AND CEILING TO BE FINISHED W/ 5/8" TYPE "X" FIRE CODE GYPSUM BOARD RO O F T R U S S A B V . @ 2 4 " O . C . 3- LIVING ROOM BRG WALL MECH. 3/0 x 6/8 FLOOR DRAIN 2' - 0" 2' - 0 " 1' - 2"1' - 2" 2' - 0 " 2' - 0 " 2959 CSMT3- DW RA N G E SI N K REF 13' - 6" 25 ' - 3 1 / 2 " 7' - 4 " 13 ' - 1 0 " 12 ' - 6 1 / 2 " 6" 6"21' - 0"5' - 8 1/2"2' - 6 1/2"10' - 9"6" NOTE: DIMENSIONS AND ROOM SIZES ARE SHOWN FOR DESIGN INTENT ONLY. DUE TO CONSTUCTION MEANS, METHODS AND TOLERANCES, ROOM SIZES ARE SUBJECT TO CHANGE WITHOUT NOTICE. FURNWH 3' - 3"5' - 5 1/2" 6"12' - 9 1/2"8' - 8" 3 1/2"6' - 1 1/2"6' - 10 1/2"6" 6' - 1 0 1 / 2 " ROOF TRUSSES TO BEAR ON HOUSE/GARAGE WALL 12" TRAY CLG. OPTIONAL 12" TRAY NICHE OPTIONAL POCKET DOOR OPTIONAL POCKET DOOR HB HB 2 A201 Sim 3 A201 Sim 2' - 0" 1/4 X 6/8 2959 CSMT 2' - 6 " 3' - 6 " 5' - 4 " 8 1 / 2 " 2' - 0 " 2' - 0" 2' - 0 " 1 3 5 . 0 0 ° 135.00° 2- 6"3' - 1 " 4' - 3 " 2' - 4 " 3' - 0 1 / 2 " 13 ' - 3 1 / 2 " W D SL O P E S L A B 6 " T O OV E R H E A D D O O R 0'-0" -0'-2" PA N T R Y CL LIN. CLO. 29 2 9 T R S M A101 3 7' - 0 " 6' - 6 " 29 5 9 C S M T 29 5 9 C S M T FULL HT. WALL A2015 6 7 A201 8 A201 9 LAV. LAV.LAV. (2) 1 3/4 x 11 7/8 LVL HDR MW H O O D RIDGEVALLEYVALLEYRI D G E RI D G EVALLEYRI D G E ROOF NOTES: 2'-0" EAVE OVERHANG*** 1' - 6" GABLE RAKES*** 9:12 SLOPE SIDE TO SIDE*** 5:12 SLOPE FRONT TO BACK*** ***UNLESS NOTED OTHERWISE PROVIDE RIDGE, HIP AND SOFFIT VENTING TO COMPLY W/ GOVERNING CODES SNOW AND ICE BARRIER ALONG ALL EAVES & RAKES 2' - 0" PAST OUTSIDE FACE OF FRAMING (TYPICAL @ ALL EXTERIOR EAVES) OUTSIDE FACE OF FRAMING BELOW 2' - 0" 1' - 6 " 2' - 0" 2' - 0" 2' - 0" 2' - 0 " 1' - 3 1 / 2 " 1' - 3 3 / 4 " 2' - 0 " 2' - 0"2' - 3 1/2" 2' - 0 " 1' - 3 3 / 4 " RI D G E 1' - 6 " 2' - 0" 1' - 6"VALLEYRI D G E 1' - 6" OVERFRAMING AS REQ'D (TYPICAL SEE ELEVATIONS) 10 ' - 6 1 / 2 " 6" 10 ' - 0 1 / 2 " 1' - 6" 2' - 0" 1' - 6 " 1' - 6 " 6" / 12"6" / 12" 6" / 12" 6" / 1 2 " 6" / 1 2 " 6" / 12"6" / 12" 6" / 12"6" / 12" 2' - 0 " 2' - 0 " 2' - 0 " OP T . FP 29 2 9 T R S M 29 2 9 T R S M 2' - 0 " 9' - 0 " 2' - 6 " 13 ' - 6 " 2' - 0 " 2' - 0 " 5' - 0 " 2' - 0 " 2' - 0 " SEE PLAN FOR WINDOW SIZE/DIMS 13 ' - 0 " 2' - 0" LIVING ROOM 12" TRAY CLG. 2' - 3"2' - 6"2' - 0"3' - 0" 9' - 9" 1' - 0 " 1' - 0 " 1" 2' - 1 " 1 1 / 2 " 3' - 0 " 3' - 0 " 2' - 6 " 2' - 6 " 1" 2' - 3 " 13 ' - 5 1 / 2 " 1' - 0"1' - 0"1" 2' - 1" 3" 2' - 0 " 3" 3' - 0 " 1' - 3 " 2 1 / 2 " 6' - 1 1 1 / 2 " 3/4"2' - 0"1' - 3 1/4" 3' - 4" REF. SI N K DW RA N G E MW H O O D PA N T R Y O. H . C . O . H . C .O.H.C.O.H.C. O.H.C. O.H.C. 3' - 0" 1' - 6"1' - 6" 1' - 1 0 1 / 2 " 5' - 1" 1/2" 1' - 0 1/4"2' - 11 1/2"1' - 0 1/4" 1/2" 1' - 1 0 1 / 2 " 1' - 1 0 1 / 2 " 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A101 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y NA P A E S T A T E P L A N MA I N F L O O R P L A N SCALE: 1/4" = 1'-0"1 MAIN FLOOR- 1380 FLOOR PLAN SCALE: 1/4" = 1'-0"2 ROOF PLAN SCALE: 1/4" = 1'-0"3 FIREPLACE OPTION SCALE: 3/8" = 1'-0"4 NAPA KITCHEN SCALE: 3/8" = 1'-0"5 NAPA BATH SCALE: 3/8" = 1'-0"6 NAPA MASTER BATH MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MAIN WIN. H.H. 6' -10" UPPER LEVEL PLT HT 18' -2 7/8" S4 S2 F1 B1 C1 M1 CONCRETE SLOPE TO GRADE L19' - 1 1 / 8 " T1 M2 M1 T2 R1 T4 F1 T7 GABLE WIN. H.H. 12' -8" T5 T6 (2) 2547 CSMT 2535 FXD T6 S4 F1 B1 T4 T7 T5 S2 1' - 6 " 4' - 0 " R1 S1 F1 T1 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE T2 R1 S1 M1 T1 F1 C1 T2 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MAIN WIN. H.H. 6' -10" T.O.F. -6" R1 C1 M1 T1 S1 GABLE WIN. H.H. 12' -8" T2 F1 M2 M1 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE FIREPLACE OPTION B TRANSOM WINDOWS 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A200 19-137.2 3-18-2021 MS P L A N ML K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y NA P A E S T A T E P L A N EL E V A T I O N S SCALE: 1/4" = 1'-0"1 FRONT SCALE: 1/4" = 1'-0"2 BACK SCALE: 1/8" = 1'-0"3 LEFT SCALE: 1/8" = 1'-0"4 RIGHT Keynote Legend Key Value Keynote Text B1 DECORATIVE BRACKET - FYPON CRAFTSMAN BRACKET BKT04X12X16RI C1 COLUMN WRAP - OR - TRIM OUT COLUMN F1 6" ALUMINUM FASCIA OR 6" ALUMINUM RAKE L1 EXTERIOR WALL LIGHT M1 MASONRY- CULTURED STONE M2 MASONRY- STONE CAP R1 LAMINATED ASPHALT ROOF SHINGLES S1 (LAP SIDING) HARDIE-PLANK SIDING-7" MAX EXPOSURE S2 (STUCCO PANEL) HARDIE PANEL S4 (SHAKE SIDING) T1 PAINTED HARDIE CORNER TRIM T2 4" PAINTED TRIM T4 6" OVER 8" PAINTED TRIM T5 7" OVER 12" PAINTED TRIM T6 5/4 X 7" PAINTED TRIM T7 4" TRIM AT WINDOWS ON FRONT ELEVATION ONLY MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" T.O.F. -6" B.O.F. -4' -0" 9' - 9 1 / 8 " 3' - 4 " 8" 8' - 1 1 / 4 " 2" 11 7 / 8 " 8' - 3 1 / 4 " 4" 2" 4" 4" 1' - 6 " 2 1/2" 2" 2" 5 1/2" 2 1/2" 2" 2 1/2" SIMPSON POST STANDOFF 6X6 TRTD TIMBER POST BLOCKING AS REQ'D PAINTED COLUMN TRIM STONE CAP SEE ROOF PLAN 36" PLASTIC ATTIC CHUTE SNOW AND ICE BARRIER EXTEND 24" PAST I.S. FACE OF EXTERIOR WALLS LAMINATED ASPHALT ROOF SHINGLES ON 15# ROOF FELT ON 1/2" O.S.B. SHEATHING MTL. DRIP 2X6 SUB-FASCIA 3/8" VENTED ALUMINUM SOFFIT & FASCIA ON 2X4 LOOKOUTS @ 24" O.C. 7" OVER 12" PAINTED TRIM SEE ELEVATIONS FOR SIDING MATERIAL WEATHER RESISTANT BARRIER OVER 1/2" O.S.B. SHEATHING ON 2X6 WALL STUDS @16" O.C. R21 INSULATION 1/2" GYP. BD. ON 6MIL POLY VAPOR BARRIER FLASHING (ALL HORIZ. JOINTS) 2X6 SILL PLATE "TRTD" ON CLOSED CELL FOAM SILL SEALER R49 BLOWN INSULATION 12 SE E R O O F PL A N MAIN FLOOR 12 " E N E R G Y H E E L M I N . T.O.F. 0'-0" 0'-4" FOUNDATION WALL-REFER TO PLAN TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL MAIN FLOOR PLT. HT. 9'-1 1/8" HOLD ALL TRIM AND SIDING MIN. 6" ABOVE GRADE 9' - 1 1 / 8 " CONTINUOUS BEAD OF SEALANT 4"4" 4' - 0 " LINE OF GRADE (VARIES) 2" 4" 2' - 0" HOLD ALL TRIM AND SIDING MIN. 6" MIN. ABOVE GRADE MAIN FLOOR 0'-0" TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL CONTINUOUS BEAD OF SEALANT 4"4" 2" 4" 2' - 0"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE GARAGE SLAB (SLOPE TO OVERHEAD DOOR) MAIN FLOOR 0'-0" TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL CONTINUOUS BEAD OF SEALANT 4"4" 2" 2' - 0"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE SLAB (SLOPE AWAY FROM HOUSE) MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8"1 1/2"3' - 0"3' - 0"2' - 6"2' - 6" 11' - 1 1/2" 1 1/2" 3' - 0" 2 1/2" 2' - 9"2' - 7"2' - 0" 10' - 8" 2 9 / 1 6 " 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 9' - 1 1 / 8 " 7' - 6 " RANGE MW HOOD MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8"3' - 0"2' - 0"2' - 6" 7' - 6" 2' - 9"1' - 3" 2 9 / 1 6 " 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 7' - 6 " REF. MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" DW 1' - 3"3' - 0" 3" 2' - 0" 3" 6' - 9" 1 1 / 2 " 2' - 1 0 1 / 2 " 3' - 0 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 1/2"5' - 0"1/2" 5' - 1" 4" 1 1 / 2 " 2' - 1 0 1 / 2 " 3' - 0 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 3' - 0" 1 1 / 2 " 2' - 1 0 1 / 2 " 3' - 0 " 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A201 19-137.2 3-18-2021 MS P L A N ML K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y NA P A E S T A T E P L A N DE T A I L S ROOM FINISH SCHEDULE- OVERALL ROOM NO ROOM NAME AREA FLOOR BASE WALLS CEILING NOTESN E S W FINISH HEIGHT 1 GUEST BEDROOM 131 SF CARPET 2 BATH 53 SF LVT 3 MASTER BEDROOM 151 SF CARPET 4 MUD/LAUN. 87 SF LVP 5 TWO CAR GARAGE 522 SF CONCRETE 6 M. BATH 92 SF LVT 7 M. CLOSET 52 SF CARPET 8 KITCHEN 136 SF LVP 9 DINING 366 SF LVP 10 PANTRY Not Placed LVP 11 GUEST CLOSET 26 SF CARPET 13 LOFT 314 SF 14 FOYER 93 SF LVP 15 LIVING ROOM Redundant Room LVP 16 MECH. 54 SF CONCRETE 17 CL 6 SF LVP 18 LIN. CLO. 5 SF LVT NOTE: AREA'S ARE PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL FLOOR AREA'S PRIOR TO BIDDING AND CONSTRUCTION NOTE: VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION DOOR SCHEDULE Type To Room: Name Door CommentsWidth Height 2/10 X 6/8 BATH 2' - 10" 6' - 8" 1/4 x 6/8 BATH 1' - 4" 6' - 8" 7282 SLDR DINING 6' - 0" 6' - 10" 3/0 x 6/8 DINING 3' - 0" 6' - 8" 3/0 X 6/8 FOYER 3' - 0" 6' - 8" 2/0 x 6/8 FOYER 2' - 0" 6' - 8" 2/10 X 6/8 GUEST BEDROOM 2' - 10" 6' - 8" 2/10 X 6/8 GUEST CLOSET 2' - 10" 6' - 8" 3/0 x 6/8 PCKT KITCHEN 3' - 0" 6' - 8" 2/8 x 6/8 M. BATH 2' - 8" 6' - 8" Interior - Double Sliding Glass Shower Door M. BATH 5' - 0" 6' - 0" 2/8 x 6/8 M. CLOSET 2' - 8" 6' - 8" 2/8 x 6/8 M. CLOSET 2' - 8" 6' - 8" 3/0 x 6/8 MECH. 3' - 0" 6' - 8" 3/0 x 6/8 MUD/LAUN. 3' - 0" 6' - 8" 16'-0" x 8'-0" TWO CAR GARAGE 16' - 0" 8' - 0" NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL DOORS PRIOR TO BIDDING AND CONSTRUCTION NOTE: VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION WINDOW SCHEDULE Level From Room: Name Type Comments MAIN FLOOR 2535 CSMT FRONT GABLE MAIN FLOOR 2547 FXD FRONT GABLE MAIN FLOOR 2959 CSMT E MAIN FLOOR 2959 CSMT E MAIN FLOOR DINING 2929 TRSM MAIN FLOOR DINING 2929 TRSM MAIN FLOOR DINING 3559 CSMT E MAIN FLOOR DINING 3559 CSMT E MAIN FLOOR DINING 2959 CSMT E MAIN FLOOR GUEST BEDROOM 2959 CSMT E MAIN FLOOR GUEST BEDROOM 2959 CSMT E MAIN FLOOR GUEST BEDROOM 2959 CSMT E MAIN FLOOR M. BATH 2935 CSMT E3 MAIN FLOOR MASTER BEDROOM 2959 CSMT E MAIN FLOOR MASTER BEDROOM 2959 CSMT E MAIN FLOOR MASTER BEDROOM 2959 CSMT E MAIN FLOOR MASTER BEDROOM 2959 CSMT E MAIN FLOOR MASTER BEDROOM 2959 CSMT E MAIN FLOOR MUD/LAUN. 2929 TRSM MAIN FLOOR TWO CAR GARAGE 2547 FXD FRONT GABLE MAIN FLOOR: 20 Grand total: 20 NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL WINDOWS PRIOR TO BIDDING AND CONSTRUCTION NOTE: VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION NOTE: GLASS SHOWER DOORS NOT INCLUDED IN SCHEDULE SCALE: 1/2" = 1'-0"4 TYP. COLUMN SCALE: 1/2" = 1'-0"1 TYPICAL SLAB ON GRADE WALL SECTION SCALE: 1" = 1'-0"2 TYP. ZERO ENTRY DETAIL - GARAGE SCALE: 1" = 1'-0"3 TYP. ZERO ENTRY DETAIL - STOOP SCALE: 1/4" = 1'-0"5 KITCHEN ELEVATION 1 SCALE: 1/4" = 1'-0"6 KITCHEN ELEVATION 2 SCALE: 1/4" = 1'-0"7 KITCHEN ELEVATION 3 SCALE: 1/4" = 1'-0"8 MASTER BATH ELEVATION SCALE: 1/4" = 1'-0"9 BATH ELEVATION SCALE: 1" = 1'-0"10 TERMITE GUARD GENERAL NOTES B. Submit floor truss layouts showing beam locations, joist layout, locations of continuous duct chases, and maximum duct size in each chase. Allow designer five days for complete review. lumber package. Allow designer five days for complete review. manufacturer for review prior to ordering roof trusses and/or roof A. Submit roof truss and/or rafter layout plan as completed by the 12. SUBMITTALS 8. DOORS AND WINDOWS A. Exterior doors shall be selected by the Owner. B. House-to-garage doors shall be fire rated doors approved by governing codes. Face design to be selected by the Owner. C. Interior doors shall be selected by the Owner. D. Exterior windows by Pella Corp as selected by owner. E. Glazing in all doors and windows shall comply with governing codes. F. Install egress window units in accordance with governing codes. G. Door and window sizes indicated or drawings are as follows: "3/0x6/8" represents a door or window 3'-0" wide x 6'-8" high. Jamb depth to be coordinated by the Contractor. H. Finish hardware shall be selected by the owner. Install hardware in accordance with governing codes. 9. FINISHES A. Gypsum wallboard, unless noted otherwise, shall be provided as follows: 1. Exterior walls: One layer 1/2" regular wallboard to interior face. 2. Interior walls: One layer 1/2" regular wallboard each face. 3. Ceiling: One layer 5/8" regular wallboard. 4. Garage/House common wall: One layer 5/8" type "X" wallboard each face. 5. Baths: Water resistant wallboard at all walls and ceilings surrounding tubs and showers and as required by governing codes. Provide cement board as substrate for ceramic tile. B. Provide metal corner bead and trim at all locations recommended by the gypsum wallboard manufacturer. C. Tape, float, and sand joints and fasteners of gypsum wallboard with three coats of joint compound as required to obtain a uniformly smooth surface. D. Finishes shall be selected by the Owner. 10. PLUMBING, MECHANICAL, AND ELECTRICAL A. Plumbing, mechanical, and electrical information and layouts shown on the Drawings is schematic in design, and shall be reviewed by sub-contractors, suppliers, and building officials for compliance with governing codes and good common construction practices. The Architect shall be notified by the Contractor of any discrepancies prior to construction. B. Plumbing, mechanical, and electrical equipment shall be selected by the Owner. C. Design and installation of plumbing, mechanical, and electrical equipment shall be the responsibility of the appropriate licensed contractors and sub- contractors. Design shall be submitted for owner's review prior to ordering D. Service panels shall be selected by the electrical sub-contractor. E. All HVAC equipment shall be individually switched. F. All outdoor, bath, and garage and spa wall receptacles shall be provided with ground fault circuit protection in accordance with governing codes. G. Dryer vents shall be extended to the exterior. H. Provide plumbing vents in accordance with governing codes. Minimize number and locate for minimal visual impact. I. Install type and number of smoke detectors in accordance with governing codes & UL217. J. Connect water, gas, and electric services in accordance with governing codes. 11. MISCELLANEOUS and installation of equipment. exterior walls install plates over foam sill sealer. C. Unless noted otherwise, all slabs on grade shall be 4" thick, reinforced with 6x6 W1.4xW1.4 W.W.M., and placed over 4" minimum compacted sand or gravel fill. Interior slabs shall be placed over 6 mil. Stabilized polyethylene vapor barrier. Coordinate with radon removal procedures. D. Footing sizes shown are typical only for stated soil pressure and consistent compaction. Contractor shall be responsible for footings complying with A. Adhered masonry flashing must be installed at wall penetrations and terminations integrated with the WRB properly (when used), and installed in accordance with the to ensure a consistent overall project color on the wall. C. Install in accordance with manufacturer's installation instructions. Visit this page for http://ncmabr.org/pdfs/masterlibrary/MVMA%20Installation%20Guide%204th%20Edition%20web.pdf Consult manufacturer for proper installation instructions. modified mortar meeting ANSI A118.4 OR ANSI 118.15. F. Touch-up, repair or replace damaged stone before completion of project. A. All structural steel shall comply with appropriate ASTM Specifications as follows: ASTM A36, ASTM A53, ASTM A501, ASTM A307, and ASTM A. Lumber shall, in addition to complying with governing codes, comply with: 1. "Product Use Manual" of the Western Wood Products Association for selection and use of products included in that manual. 2. "Plywood Specification and Grade Guide" of the American Plywood 3. "Standard Specifications for Grades of California Redwood Lumber" of 4. American Wood Preservers Association standards and recommendations for fire-retardate and preservative pressure treated lumber and plywood. 5. Western Red Cedar Lumber Association standards and recommendations the Redwood Inspection Bureau for Redwood. for cedar. Association. D. Application details and mortar recommendations may vary depending on the stone style. E. All dry-stacked and large format standard stones must be applied using a polymer - 5. METALS A325. 6. WOOD AND PLASTICS the design requirements of specific soil conditions. of the stone veneer. Assure that all flashing and kickouts are corrosion resistant, local building code requirements. B. Product should be pulled from a variety of boxes and blended on site during intalllation installation instructions: 4. MASONRY Install skylights according to the manufactures' recommendations. I. Install water and ice barrier (Bituthene or equal) over roof sheathing at all eaves and valleys. water & ice barrier to extend 24" past outside face of L. Provide 2" nominal pressure treated lumber over foam sill sealer beneath full bearing of wood beams bearing on concrete or 7. THERMAL AND MOISTURE PROTECTION A. Provide thermal building insulation at assemblies adjacent to exterior or unheated spaces meeting the requirements of governing codes and, unless noted otherwise, meeting the following minimum requirements: 1. Foundations: 1 1/2"extruded polystyrene (R-10) 2. Walls: glass fiber batt (R-20) U.N.O. 3. Floors: glass fiber batt (R-30) -for floors over unconditioned space or exterior 4. Ceilings: glass fiber batt (R-49) 5. Install continuous blankets without holes for electrical boxes, lighting fixtures, or heating ductwork. B. Install 6 mil. stabilized polyethylene vapor barrier against interior face of all C. Waterproof foundation walls at excavated areas from footing to finished grade with two coats of asphalt based waterproofing compound for full basements. D. Roofing shall be 240 lb. (minimum) composition shingles installed over 15 lb. roof felt on roof sheathing. Minimum slope, fasteners, under layment, and exposure according to manufacturers' recommendations. E. Provide flashing and sheet metal required to prevent penetration of water through the exterior shell of the building. In addition to complying with governing codes, comply with pertinent recommendations contained in the current edition of "Architectural Sheet Metal Manual" published by SMCNA. All iron sheet metal flashing shall be hot-dipped galvanized complying with F. Provide gutters and downspouts to provide positive roof and site drainage. G. Provide attic and roof ventilation as required by governing codes and as shown on the Drawings. Provide appropriate soffit and roof vents. H. Skylights shall be selected by the Contractor and approved by the owner. ASTM A93. thermal insulation. masonry. 1. Before final Drawings and Specifications are issued for construction, they shall be submitted to all governing building agencies to insure their compliance with all applicable local and national codes. If code discrepancies in Drawings and/or Specifications appear, the Architect shall be notified of such discrepancies in writing by the Contractor or building official, and allowed to alter the drawings and specifications so as to comply with governing codes before construction begins. 2. Upon written receipt of approval from the governing official, approved final Drawings and Specifications shall be submitted to the Contractor by 3. If code discrepancies are discovered during the construction process, the Architect shall be notified and allowed ample time to remedy said 4. All work performed shall comply with all applicable local, state and national building codes, ordinances and regulations, and all other B. All contractors, suppliers, and fabricators shall be responsible for the content of the Drawings, and for the supply and design of appropriate C. All manufactured articles, materials, and equipment shall be handled, applied, installed, erected, used, cleaned, and conditioned in strict accordance with the D. All alternates are at the option of the Owner and shall be at the Owner's request, constructed in addition to or in lieu of the typical construction, as dead load 15psf (10 psf top, 5psf bottom) dead load 15psf (10 psf top, 5psf bottom) 5. Prior to start of construction, verify design loads with governing codes and site conditions. Check with local building agencies for wind, seismic, snow and other special loading conditions. If discrepancies are discovered, Architect shall be notified according to Section 1.A.1 above. A. Perform excavation, according to good common construction practices, to the lines, grades, and elevations indicated on the Drawings. B. Provide consistent compaction of the top 8" of sub-grade, fill, and backfill material beneath structures, walks, and pavements to meet the stated soil C. Provide soil poisoning to control termites as required by governing codes. D. Provide and install ventilation for Radon Gas as required by local building A. Provide concrete complying with ASTM C94. Unless otherwise noted, concrete shall have the following 28 day compressive strengths as minimums: 2. Concrete floor slabs, walks, drives, and patios: 3,500psi 3. Provide construction joints so panel size does not exceed 400sf. B. Provide reinforcement of the size and spacing indicated on Drawings. Reinforcing shall comply with the following minimums: live load 60psf (maximum) live load 40psf (maximum) live load 30psf (maximum) agencies and governing codes. 1. Concrete footings and foundations: 3,000psi 1. Bars: ASTM A615, grade 40, deformed bars. 2. Welded Wire Fabric: ASTM A185. 3. CONCRETE 2. SITE WORK pressure. materials and work performance. manufacturers' requirements. indicated on the Drawings. 3. Balconies and Decks: 4. Soil Pressure: 1500 psf (minimum) 2. Floor: 1. Roof: E. Design Loads: dead load 10psf 1. GENERAL REQUIREMENTS authorities having jurisdiction. discrepancies. the Architect. A. Codes: drawings to designer for review prior to construction. spacing of all trusses. Contractor to submit truss drawings and/or roof framing b. Install joist and beam hangers capable of supporting the maximum allowable load of joist or beam being supported. C. Provide "Micro-Lam" glue laminated veneer lumber beams (manufactured by Truss Joist Corporation) or equal, of the dimensions and number indicated on the drawings. Provide exterior grade Micro Lams for deck framing and other in strict accordance with manufacturers' recommendations. a. Modulus of elasticity: 2,000,000 psi b. Flexural (12" depth): 2,900 psi c. Horizontal shear: 285 psi D. Provide wood trusses able to sustain the stated loads for the spans, profiles, and arrangement shown on the Drawings. Truss layout is schematic only. Truss manufacturer and/or engineer shall be responsible for the design and E. All roof trusses shall be installed with metal truss seats as specified by the F. Unless noted otherwise, provide: 1. Double header joists and trimmers at all floor openings. 2. Double joists under all partitions parallel to joists. 3. Double 2x12 headers with 1/2 OSB between at all door and window openings in 2x4 walls. Triple 2x10 headers with 1/2" OSB between at all door and window openings at 2x6 walls. 4. For solid sawn joists, provide one row of 1x3 cross-bridging or metal bridging G. Stud spacing at all exterior and bearing walls shall be 16" o.c. minimum. H. Stud walls shall not exceed the following heights without continuous lateral support perpendicular to the plane of the wall at the stated height or less. Studs shall be continuous between points of lateral support. I. Unless noted otherwise, rafters, ceiling joists, collar ties, and purlins shall be sized and spaced in accordance with FHA requirements or governing codes, J. Stair construction shall consist of (3)2x12 stringers, 5/4" or 2x thick tread and 3/4" thick risers or, shall be fabricated by component manufacturer. K. All wood plates bearing on concrete or masonry shall be pressure treated. At b. 2x6: 12'-0' 2. Non-bearing walls: a. 2x4: 14'-0" b. 2x6: 20'-0" whichever is more restrictive. 1. Bearing walls: a. 2x4: 10'-0" for each 8'-0" of joist span. d. Bearing: 550 psi truss manufacturer. 1. Allowable stresses: B. Provide lumber and materials meeting or exceeding the following standards of a. Studs: Douglas Fir-Larch, Stud Grade -or as approved by building code. b. Headers and Beams: Douglas Fir-Larch, No. 2 and better -or as appoved by building code. 2. All headers and beams shall be free from splits, checks, and shakes. a. Roof: 1/2" OSB APA RATED SHEATHING, EXP 1. b. Walls: 1/2" OR 7/16" OSB APA RATED SHEATHING, EXP 1. c. Floor: 23/32" plywood APA RATED SHEATHING, EXP 1. d. Proper oriented strand board may be substituted for plywood. steel at exterior locations. a. Steel items: Comply with ASTM A36; use galvanized 3. Sheathing: (with clips) (glue and nail) 4. Rough Hardware: 1. Framing Members: quality: Contractor to submit steel shop drawings to designer or a licensed structural Construction and shall be detailed by a qualified structural steel detailer. B. All steel connections shall be designed according to AISC Manual of Steel engineer prior to steel erection. C. Architect will not be responsible for any errors in the roof and/or floor framing without the opportunity to review the roof and/or floor framing layouts. Framing layouts, member sizes, and floor/roof penetrations indicated on the drawings are for design intent only. Final layouts shall be the responsibility of builder. exterior applications. Unless noted otherwise, fasten multiple beams together exterior wall below. And as shown on the roof plan. A. This set of construction drawings is intended for design intent only. Although many jurisdictions will accept these drawings as sufficient for a construction permit, these drawings are not intended, and should not be construed, as a complete set of construction drawings. These drawings will have to be adapted to meet local zoning and/or site conditions and additional detailing will need to be completed on site by the builder. B. Install prefabricated fireplace units as shown on Drawings. 1. Fireplace units shall be "Heat-N-Glo" or as approved by Owner. 2. Contractor shall be responsible for proper installation as recommended by the manufacturer and as required by governing codes, including mantel and hearth design and location. C. Room sizes shown on the plans indicate room dimensions prior to installation of gypsum wall board. Gypsum wall board thickness must be subtracted from room sizes indicated for actual room dimensions and are subject to change. 2. Use exterior grade Micro-Lam in all areas subject to moisture. 3. Hearth shall be of non-combustible material. E. All excavations located beneath interior floor slabs (including garage) shall be inspected by a geotechnical engineer for bearing and the presence of unsuitable soils. If unsuitable soils are identified, the contractor shall follow the recommendations of the geotechnical engineer. F. All excavations located beneath footings and foundations shall be inspected by a geotechnical engineer for bearing and the presence of unsuitable soils. If unsuitable soils are identified, the contractor shall follow the recommendations of the geotechnical engineer. EARTH RIGID INSULATION CONCRETE BLOCK CONCRETE BRICK PLYWOOD STEEL OR STEEL STUD WALL BATT INSULATION GYPSUM BOARD GRAVEL WOOD OR WOOD STUD WALL SOUND INSULATION IN WALL MIN. (3) 2X SOLID BLOCKING BEARING WALL MATERIALS ELEVATION DRAWING NUMBER WALL TYPE DECORATIVE COLUMN TYPE SHEET NUMBER SHEET NUMBER SECTION DRAWING NUMBER DETAIL DRAWING NUMBER SHEET NUMBER POINT LOAD FROM ABOVE ELEVATION HEIGHT ELEVATION TYPE W2 C1 SYMBOLS 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : IS S U E D F O R : 11 - 2 3 - 2 0 FO R C O N S T R U C T I O N 11 - 3 0 - 2 0 RE V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 RE V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 OW N E R R E Q U E S T E D C H A N G E S A0 19-137.2 3-18-2021 MS P L A N LR KC VI N T A G E E S T A T E S - N O R T H L I B E R T Y SO N O M A E S T A T E P L A N TI T L E S H E E T SHEET LIST Sheet Number Sheet Name A0 TITLE SHEET A100 FOUNDATION PLAN A102 MAIN FLOOR PLAN A200 ELEVATIONS A201 DETAILS AREA SCHEDULE Level Name Area MAIN FLOOR Area 1769 SF MAIN FLOOR Area 555 SF MAIN FLOOR: 2 2324 SF Grand total: 2 2324 SF NOTE: THIS DRAWING IS AN ARTISTIC INTERPRETATION OF THE GENERAL APPEARANCE OF THE DESIGN. IT IS NOT INTENDED TO BE AN EXACT RENDITION. MAIN FLOOR 0" T.O.F. -6" B.O.F. -4' -0" W3W1W2 1' - 4"1' - 4"1' - 4" 1' - 0 " 3' - 2 " 8" 8"8"8" 8"8" 4' - 0 " STEP DOWN FOUNDATION AT O.H.D.- VERIFY FOUNDATION HEIGHT WITH GRADE 6" 3' - 6 " CF 16 1' - 4" 10 " W4 1' - 4" 6" 3' - 8 " 8" 8" W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W4 W4 W4 W4W4 W2 W2 W2 29' - 0" 30' - 4"11' - 8" 42' - 0" 13 ' - 2 " 12 ' - 8 " 38 ' - 1 0 " 5' - 0 " 69 ' - 8 " 22' - 6" 1' - 6" 6' - 0" 12' - 0" 42' - 0" 3' - 10" 16' - 4" 2' - 4" 5' - 0 " 2 2 ' - 8 " 42 ' - 0 " 69 ' - 8 " 12 ' - 0 " 26' - 8" 40' - 8" 8" 22' - 8" 8" 17' - 4" 8" 8" 11 ' - 8 " 10 ' - 4 " STEP DOWN FOOTING AT O.H.D. NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL NOTE: STEP FOOTINGS DOWN AS GRADE REQUIRES. MAINTAIN MINIMUM FROST PROTECTION AT ALL TIMES. NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL STOOP ABOVE PATIO ABOVE GARAGE ABOVE W2 W3 TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL NOTE: STEP FOOTINGS DOWN AS GRADE REQUIRES. MAINTAIN MINIMUM FROST PROTECTION AT ALL TIMES. TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL DOWEL STOOP SLAB TO FOUNDATION DOWEL STOOP SLAB TO FOUNDATION 1' - 0 " 2' - 4 " 7' - 0 " 2' - 4 " 8" 2' - 4" -VERIFY ALL CHANGES IN WALL ELEVATION ON SITE -MAINTAIN 42" MINIMUM FROST PROTECTION AT ALL TIMES POST P20 FOOTING F30 F24 CF16 1'-8'' 2'-6'' 2'-0'' 1'-4'' DIA 2'-6'' 2'-0'' CONT 4'-0'' 1'-0'' 1'-0'' 10'' (2) #4 CONT. #4 AT 12" O.C. E.W. #4 AT 12" O.C. E.W. (2) #4 CONT. -NOT ALL TYPES ARE USED F36 3'-0'' 3'-0'' 1'-0'' #4 AT 12" O.C. E.W. 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A100 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y SO N O M A E S T A T E P L A N FO U N D A T I O N P L A N SCALE: 1/4" = 1'-0"2 FOOTING LEGEND SCALE: 1/4" = 1'-0"1 FOUNDATION PLAN FOUNDATION SCHEDULE Type Mark WALL FOOTING CommentsWidth Unconnected Height Hotizontal Reinforcements Vertical Reinforcements Footing Width Footing Length Footing Depth Footing Reinforcing W1 8" 3' - 6" #4 @ TOP & BOT. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. W2 8" 4' - 0" #4 @ 24" O.C. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. W3 8" 3' - 2" #4 @ 48" O.C. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. W4 8" 3' - 8" #4 @ 48" O.C. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. 42' - 0" 24' - 0" 6' - 0" 12' - 0" 38 ' - 1 0 " 25 ' - 1 0 " 64 ' - 8 " 4' - 7 1 / 2 " 6" 30' - 4"11' - 8" 42' - 0" 64 ' - 8 " 11'-1 1/8" CLG. 2/ 1 0 x 6 / 8 2/10 x 6/8 5/0 x 6/8 2/4 x 6/8 3/ 0 x 6 / 8 C . O . 5/0 x 6/8 C.O. 3/ 0 x 6 / 8 3/ 0 x 6 / 8 12' - 0" 12' - 0" 3' - 0" 3' - 0" 6' - 0" 6' - 0" 18 ' - 5 " 1 2 ' - 4 1 / 2 " 8 ' - 0 1 / 2 " 5 ' - 1 0 " 6 ' - 1 0 " 6 ' - 0 1 / 2 " 7 ' - 1 1 / 2 " 16' - 10" 3' - 8" 3' - 8" 3' - 8" 2' - 6" 5' - 2" 6' - 6" 6' - 0 " 14 ' - 0 " 10 ' - 1 1 1 / 2 " 11 ' - 0 1 / 2 " 22 ' - 8 " 2/10 x 6/8 D. D.W. 2/10 x 6/8 ROOF TRUSS ABV. @ 24" O.C. O.H.C. 6" 6' - 9 1/2" 2' - 4 1/2" 3' - 10 1/2" 27' - 11 1/2" 6" 6" 3' - 5 " 4' - 0 " 5' - 9 " 12 ' - 4 1 / 2 " 5 1 / 2 " 7' - 7 1 / 2 " 3 1 / 2 " 3' - 1 " 4' - 0 1 / 2 " 5 1 / 2 " 22 ' - 2 " 6" 6" 10 ' - 0 " 3' - 2 " 12 ' - 4 1 / 2 " 4' - 6 " 11 ' - 0 " 5 1 / 2 " 3/ 0 x 6 / 8 C . O . 6" 8' - 6" 4' - 6 1/2" 2' - 2" 25' - 9 1/2" 6" LIVING ROOM DININGDEN MASTER BEDROOM MUD/LAUN. KITCHEN PA N T R Y TWO CAR GARAGE FOYER GUEST BEDROOM BATH 2959 CSMT 29 2 9 T R S M 2965 CSMT 72 8 2 S L D R 29 6 5 C S M T 2947 CSMT2929 TRSM2929 TRSM2947 CSMT 3 1/2" 2' - 0" 11' - 0" 2' - 0" 6" 3' - 6" 10' - 6 1/2" 15' - 3 1/2" 6" 29 2 9 T R S M 29 3 5 C S M T 29 3 5 C S M T W.C. 6" 11 ' - 1 0 " 2 ' - 6 1 / 2 " 5 ' - 1 0 " 2' - 5 " 15 ' - 2 1 / 2 " 3- 4- 3- 3- 3- 2- D.T.D. 3' - 6" G.T.A. GIRDER TRUSS ABOVE(2) 1 3/4 X 11 7/8 LVL HEADER 16/0 X 8/0 O.H.D. LINE OF O.H.D. IN OPEN POSITION NOTE: WALLS AND CEILING TO BE FINISHED W/ 5/8" TYPE "X" FIRE CODE GYPSUM BOARD ATTIC ACCESS PER CODE 60 8 0 RO O F T R U S S A B V . @ 2 4 " O . C . ROOF TRUSS ABV. @ 24" O.C. MECH. 3/0 x 6/8 2/ 4 x 6 / 8 W.C.R/SR/S 2/ 1 0 x 6 / 8 2/ 1 0 x 6 / 8 M. BATH M. CLOSET COVERED PORCH W. 2/10 x 6/8 REF RA N G E SI N K 6" 23' - 0" 6" 6' - 0" 6" 3' - 11 1/2" 7' - 0 1/2" 6" 6" 11' - 0" 4' - 2 1/2" 11' - 9 1/2" NOTE: DIMENSIONS AND ROOM SIZES ARE SHOWN FOR DESIGN PURPOSES ONLY. DUE TO CONSTRUCTION MEANS, METHODS AND TOLERANCES, ROOM SIZES ARE SUBECT TO CHANGE WITHOUT NOTICE. 11'-1 1/8" CLG. 2/ 1 0 x 6 / 8 29 3 5 C S M T GARAGE FLOOR 4 A201 2' - 0 " 4 SHELVES BEAR TRUSSES ON THIS WALL 2' - 4 " 7 ' - 0 " 2 ' - 4 " 2' - 4" 1' - 2 1/2" 5' - 0 1/2" 7' - 9 1/2" OPTIONAL 12" TRAY 12" TRAY CLG. FURN WH HB HB 3 A201 Sim 2 A201 Sim 2' - 1" OPTIONAL POCKET DOOR F.D. 2' - 0"2' - 0" 2' - 0 " A102 3 SH E L V E S NICHE 135.00° SL O P E S L A B 6 " T O OV E R H E A D D O O R 0'-0" -0'-2" CL 1 CL 2 CL 3 O.H.C A102 5 A2017 6 5 A201 8 O.H.C. A201 9 A201 (2) 1 3/4x11 7/8 LVL HDR MW H O O D LAV. LAV. LAV. A201 12 A201 11 3' - 6 1 / 2 " 9 ' - 7 " 3' - 11" 3' - 4" 3' - 10" 3' - 4" COVERED PORCH 14 CO U N T E R T O P 5 1 / 4 " / 1 2 " 5 1 / 4 " / 1 2 " 6" / 12" 6" / 12" 6" / 12"6" / 12" 6" / 12"6" / 12" RIDGE RI D G E RI D G E RI D G EVALLEYVALLEYVALLEYVALLEYVALLEYROOF NOTES: 2' - 0" EAVE OVERHANG*** 2' - 0" GABLE RAKES*** 9:12 SLOPE SIDE TO SIDE 8:12 SLOPE FRONT TO BACK ***UNLESS NOTED OTHERWISE PROVIDE RIDGE, HIP AND SOFFIT VENTING TO COMPLY W/ GOVERNING CODES SNOW AND ICE BARRIER ALONG ALL EAVES & RAKES 2' - 0" PAST OUTSIDE FACE OF FRAMING (TYPICAL @ ALL EXTERIOR EAVES) OUTSIDE FACE OF FRAMING BELOW 2' - 0 " 2' - 0" 2' - 0" 2' - 0 " 2' - 0 " 2' - 0" D.W. O.H.C. REF RA N G E MUD/LAUN. KITCHEN 3/0 x 6/8 3/ 0 x 6 / 8 3/ 0 x 6 / 8 C . O . 2/ 1 0 x 6 / 8 2/10 x 6/8 PA N T R Y LO C K E R O.H.C. W.D. A2017 6 5 A201 O.H.C. MW HO O D 3' - 3" 3' - 3" 1 1/2" 3' - 0" 1 1/2" 9' - 9" 1' - 3 " 2 ' - 6 1 / 2 " 1 ' - 3 " 1 " 5' - 1 1 / 2 " 1/ 2 " 3' - 0 " 2' - 0 " 3' - 0 " 1' - 6 " 9' - 7 " 1 3/8" 3' - 0" 1 3/8" 3' - 3" 3' - 3" 1 3/8" 3' - 0" 1 3/8" 12' - 11 1/2" 1' - 0 " A201 12 O.H.C. O.H.C. O.H.C. O. H . C . O. H . C . O.H.C. MECH. 3' - 10" 3' - 4" 3/4"2' - 0"1' - 3 1/4" 4' - 6 " 14 D.W. O.H.C. REF RA N G E LO C K E R D.W. MUD/LAUN. MECH.KITCHEN 3/ 0 x 6 / 8 3/0 x 6/8 2/10 x 6/8 2/ 6 x 6 / 8 3/ 0 x 6 / 8 C . O . PANTRY O. H . C . O.H.C A2017 6 5 A20110 O.H.C. 1' - 3 " 2 ' - 6 1 / 2 " 1 ' - 3 " 2 ' - 3 " 2 ' - 3 " 9' - 6 1 / 2 " 3' - 3" 3' - 3" 1 1/2" 3' - 0" 1 1/2" 9' - 9" 1/ 2 " 3' - 0 " 2' - 0 " 3' - 0 " 1' - 6 " 1/ 2 " 9' - 7 " 1' - 0" 1' - 1" 2' - 1" 2' - 6" 2' - 6" 5' - 0" A201 12 A201 11 O. H . C . O.H.C O.H.C. MW H O O D 3/4" 2' - 0" 1' - 3 1/4" 3' - 4" 14 OPT. FP 3' - 1 1/2" 5' - 0" 3' - 2" 2965 CSMT 29 2 9 T R S M 4- 3- 2' - 0 " 1 3 ' - 2 1 / 2 " LIVING ROOM 1" 3' - 0" 1' - 3" 3' - 0" 1" 7' - 5" 1' - 1 0 1 / 2 " 1' - 1 0 1 / 2 " 3' - 6" 1' - 9" 1' - 9" 1' - 1 0 1 / 2 " 1' - 1 0 1 / 2 " 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A102 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y SO N O M A E S T A T E P L A N MA I N F L O O R P L A N SCALE: 1/4" = 1'-0"1 MAIN FLOOR SCALE: 1/4" = 1'-0"2 ROOF PLAN SCALE: 1/4" = 1'-0"3 KITCHEN/MUD - OPTION B SCALE: 1/4" = 1'-0"4 KITCHEN/MUD - OPTION C SCALE: 1/4" = 1'-0"5 FIREPLACE OPTION SCALE: 1/4" = 1'-0"6 SONOMA MASTER BATH SCALE: 1/4" = 1'-0"7 SONOMA BATH MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MAIN WIN. H.H. 6' -10" F1 R1 S3 C1 M1 S1 L1 CONCRETE SLOPE TO GRADE B3 S4 T4 T5 T1 T7 F1 (3) 2941 CSMT (2)2517 CSMT T7 T8 T8 T5 S4 B3 +8" +0" S3 +8" +0"T4 M2 M1 T2 S1 T7 T2 MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MAIN WIN. H.H. 6' -10" R1 F1 S1 C1 M1 T2 F1M2 F1 S1 T1 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE S1 F1 C1 M1 L1 T2 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE F1M2 R1 F1 C1 M1 S1 T1 T2 T5HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE F1M2 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A200 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y SO N O M A E S T A T E P L A N EL E V A T I O N S SCALE: 1/4" = 1'-0"1 FRONT SCALE: 1/4" = 1'-0"2 BACK SCALE: 1/8" = 1'-0"3 LEFT SCALE: 1/8" = 1'-0"4 RIGHT Keynote Legend Key Value Keynote Text B3 DECORATIVE BRACKET - FYPON BKT25X27 C1 COLUMN WRAP - OR - TRIM OUT COLUMN F1 6" ALUMINUM FASCIA OR 6" ALUMINUM RAKE L1 EXTERIOR WALL LIGHT M1 MASONRY- CULTURED STONE M2 MASONRY- STONE CAP R1 LAMINATED ASPHALT ROOF SHINGLES S1 (LAP SIDING) HARDIE-PLANK SIDING-7" MAX EXPOSURE S3 (BOARD AND BATTEN SIDING) VERTICAL SIDING AND HARDIE TRIM S4 (SHAKE SIDING) T1 PAINTED HARDIE CORNER TRIM T2 4" PAINTED TRIM T4 6" OVER 8" PAINTED TRIM T5 7" OVER 12" PAINTED TRIM T7 4" TRIM AT WINDOWS ON FRONT ELEVATION ONLY T8 4" OVER 6" PAINTED TRIM 1X3 BATTENS ON SMOOTH PANEL SIDING MAIN FLOOR 0" T.O.F. -6" B.O.F. -4' -0" PAINTED COLUMN TRIM 6X6 TREATED TIMBER POST SIMPSON POST STANDOFF BLOCKING AS REQUIRED VENEER STONE STONE CAP HOLD VENEER UP 2" FROM LANDSCAPE 3' - 6 " SEE ROOF PLAN 36" PLASTIC ATTIC CHUTE SNOW AND ICE BARRIER EXTEND 24" PAST I.S. FACE OF EXTERIOR WALLS LAMINATED ASPHALT ROOF SHINGLES ON 15# ROOF FELT ON 1/2" O.S.B. SHEATHING MTL. DRIP 2X6 SUB-FASCIA 3/8" VENTED ALUMINUM SOFFIT & FASCIA ON 2X4 LOOKOUTS @ 24" O.C. 7" OVER 12" PAINTED TRIM SEE ELEVATIONS FOR SIDING MATERIAL WEATHER RESISTANT BARRIER OVER 1/2" O.S.B. SHEATHING ON 2X6 WALL STUDS @16" O.C. R21 INSULATION 1/2" GYP. BD. ON 6MIL POLY VAPOR BARRIER FLASHING (ALL HORIZ. JOINTS) 2X6 SILL PLATE "TRTD" ON CLOSED CELL FOAM SILL SEALER 4" PERF. DRAIN WILE W/ SILT SLEEVE R49 BLOWN INSULATION 12 SE E R O O F PL A N MAIN FLOOR 12 " E N E R G Y H E E L M I N . T.O.F. 0'-0" 0'-4" FOUNDATION WALL-REFER TO PLAN TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL MAIN FLOOR PLT. HT. 9'-1 1/8" HOLD ALL TRIM AND SIDING MIN. 6" ABOVE GRADE 9' - 1 1 / 8 " CONTINUOUS BEAD OF SEALANT 4"4" 4' - 0 " LINE OF GRADE (VARIES) 2" 4" 2' - 0" 4" PERF. DRAIN WILE W/ SILT SLEEVE HOLD ALL TRIM AND SIDING MIN. 6" MIN. ABOVE GRADE MAIN FLOOR 0'-0" TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL CONTINUOUS BEAD OF SEALANT 4"4" 2" 4" 2' - 0"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE GARAGE SLAB (SLOPE TO OVERHEAD DOOR) MAIN FLOOR 0'-0" TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL CONTINUOUS BEAD OF SEALANT 4"4" 2" 2' - 0"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE SLAB (SLOPE AWAY FROM HOUSE) MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" REF 2' - 1 0 1 / 2 " 1 1 / 2 " 1' - 6 " 3 ' - 0 " 7' - 6 " 1 1/2" 3' - 0" 1 1/2" 3' - 3" 3' - 3" 9' - 9" 6' - 0 " 1 ' - 6 " 7' - 6 " 1 1/2" 3' - 0" 1 1/2" 3' - 3" 3' - 3" 9' - 9" MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" DW 1/2" 3' - 0" 2' - 0" 3' - 0" 1' - 6" 1/2" 9' - 7" 1 1 / 2 " 2' - 1 0 1 / 2 " 3' - 0 " WINDOWS BEYOND MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" PANTRY MW HOOD RANGE 1' - 3" 2' - 6" 1' - 3" 1 1/4" 5' - 1 1/4" 1' - 3"2' - 6 1/2"1' - 3" 1" 5' - 1 1/2" 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 7' - 6 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 1"3' - 0"1' - 3"3' - 0"1" 7' - 5" 1 1 / 2 " 2' - 1 0 1 / 2 " 3' - 0 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 3' - 6" 2' - 1 0 1 / 2 " 1 1 / 2 " 3' - 0 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8"1' - 3" 2' - 6" 1' - 3" 2' - 3" 2' - 3" 9' - 6" 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 7' - 6 " 1' - 3" 2' - 6 1/2"1' - 3" 2' - 3" 2' - 3" 9' - 6 1/2" MW HOOD RANGE MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 3' - 0 " 4' - 6 " 7' - 6 " W.D. 2' - 6" 2' - 6" 5' - 0" MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 7' - 6 " 3' - 0 " 4' - 6 " 1 3/8" 3' - 0" 1 3/8" 3' - 3" 3' - 3" 1 3/8" 3' - 0" 1 3/8" 12' - 11 1/2" W.D. MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MAIN WIN. H.H. 6' -10" 2' - 1 0 1 / 2 " 1 1 / 2 " 3' - 0 " 7' - 6 1/2" COUNTERTOP 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A201 19-137.2 3-18-2021 MS P L A N ML K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y SO N O M A E S T A T E P L A N DE T A I L S DOOR SCHEDULE Level Location Width Height Material Finish Comments MAIN FLOOR FOYER - OPENING 0" 0" MAIN FLOOR BATH 2' - 10" 6' - 8" MAIN FLOOR DINING 6' - 0" 6' - 10" MAIN FLOOR BEDROOM CL 5' - 0" 6' - 8" MAIN FLOOR BEDROOM 2' - 10" 6' - 8" MAIN FLOOR LIVING RM - OPENING 0" 0" MAIN FLOOR LINEN 2' - 4" 6' - 8" T.O.F. GARAGE OHD 16' - 0" 8' - 0" MAIN FLOOR FOYER 5' - 2" 7' - 0" 3/0X6/8 W/SIDELIGHTS MAIN FLOOR MUD 3' - 0" 6' - 8" MAIN FLOOR MASTER 2' - 10" 6' - 8" MAIN FLOOR DEN 5' - 0" 6' - 8" MAIN FLOOR KITCHEN - OPENING 0" 0" MAIN FLOOR PANTRY 2' - 10" 6' - 8" MAIN FLOOR MUD CL 2' - 4" 6' - 8" MAIN FLOOR MECH 3' - 0" 6' - 8" MAIN FLOOR M. BATH 2' - 10" 6' - 8" MAIN FLOOR M. WIC 2 2' - 10" 6' - 8" MAIN FLOOR TOILET 2' - 10" 6' - 8" MAIN FLOOR M. WIC 3 2' - 10" 6' - 8" MAIN FLOOR M. WIC 4 2' - 10" 6' - 8" MAIN FLOOR M. WIC 5 2' - 6" 6' - 8" MAIN FLOOR 655 5' - 0" 6' - 0" WINDOW SCHEDULE Location Width Height Material Finish Comments BATH 2' - 5" 2' - 11 1/16" BEDROOM 1 2' - 5" 4' - 11 1/16" BEDROOM 2 2' - 5" 4' - 11 1/16" BEDROOM 3 2' - 5" 4' - 11 1/16" DEN 1 2' - 5" 2' - 5 1/16" DEN 2 2' - 5" 2' - 5 1/16" DEN 3 2' - 5" 2' - 5 1/16" LAUNDRY 1 2' - 5" 2' - 11 1/16" LAUNDRY 2 2' - 5" 2' - 11 1/16" LIVING ROOM 1 2' - 5" 2' - 5 1/16" LIVING ROOM 2 2' - 5" 2' - 5 1/16" LIVING ROOM 3 2' - 5" 2' - 5 1/16" LIVING ROOM 4 2' - 5" 2' - 5 1/16" LIVING ROOM 5 2' - 5" 5' - 5 1/16" LIVING ROOM 6 2' - 5" 5' - 5 1/16" LIVING ROOM 7 2' - 5" 5' - 5 1/16" M.BATH 1 2' - 5" 2' - 11 1/16" M.BED 1 2' - 5" 3' - 11 1/16" M.BED 2 2' - 5" 2' - 5 1/16" M.BED 3 2' - 5" 2' - 5 1/16" M.BED 4 2' - 5" 3' - 11 1/16" M.BED 5 2' - 5" 5' - 5 1/16" M.BED 6 2' - 5" 5' - 5 1/16" M.BED 7 2' - 5" 5' - 5 1/16" MAIN GABLE 1 2' - 5" 3' - 5 1/16" MAIN GABLE 2 2' - 5" 3' - 5 1/16" MAIN GABLE 3 2' - 5" 3' - 5 1/16" PORCH GABLE 1 2' - 1" 1' - 5 1/16" PORCH GABLE 2 2' - 1" 1' - 5 1/16" ROOM FINISH SCHEDULE-MAIN FLOOR Level ROOM NO ROOM NAME AREA FLOOR BASE WALLS CEILING CEILING NOTESN E S W HEIGHT MAIN FLOOR 030 LIVING ROOM 279 SF LVP MAIN FLOOR 031 DINING 207 SF LVP MAIN FLOOR 032 DEN 133 SF CARPET MAIN FLOOR 033 MASTER BEDROOM 192 SF CARPET MAIN FLOOR 034 M. BATH 84 SF LVT MAIN FLOOR 036 MUD/LAUN. 67 SF LVP MAIN FLOOR 037 KITCHEN 117 SF LVP MAIN FLOOR 038 PANTRY 7 SF LVP MAIN FLOOR 040 TWO CAR GARAGE 510 SF CONCRETE MAIN FLOOR 041 FOYER 70 SF LVP MAIN FLOOR 042 GUEST BEDROOM 137 SF CARPET MAIN FLOOR 043 BATH 52 SF LVT MAIN FLOOR 045 MECH. 57 SF CONCRETE MAIN FLOOR 049 M. CLOSET 53 SF CARPET MAIN FLOOR 053 COVERED PORCH Not Enclosed MAIN FLOOR 054 PANTRY 13 SF LVP MAIN FLOOR 055 CL 1 6 SF LVP MAIN FLOOR 056 CL 2 8 SF LVP MAIN FLOOR 057 CL 3 15 SF CARPET MAIN FLOOR 058 COVERED PORCH Not Enclosed NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSED ONLY GENERAL CONTRACTOR TO VERIFY ALL SCHEDULE PRIOR TO BIDDING AND CONSTRUCTION. VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION. SCALE: 1/2" = 1'-0"4 COLUMN DETAIL SCALE: 1/2" = 1'-0"1 TYPICAL SLAB ON GRADE WALL SECTION SCALE: 1" = 1'-0"2 TYP. ZERO ENTRY DETAIL - GARAGE SCALE: 1" = 1'-0"3 TYP. ZERO ENTRY DETAIL - STOOP SCALE: 1/4" = 1'-0"5 BASE KITCHEN/OPTION B + C ELEV. SCALE: 1/4" = 1'-0"6 KITCHEN ISLAND ELEV. SCALE: 1/4" = 1'-0"7 BASE KITCHEN/OPTION B ELEV. SCALE: 1/4" = 1'-0"8 MASTER BATH ELEVATION SCALE: 1/4" = 1'-0"9 BATH ELEVATION SCALE: 1/4" = 1'-0"10 KITCHEN ELEVATION - OPTION C SCALE: 1/4" = 1'-0"11 LAUNDRY ELEVATION 1 SCALE: 1/4" = 1'-0"12 LAUNDRY ELEVATION - OPTION B SCALE: 1" = 1'-0"13 TERMITE GUARD SCALE: 1/4" = 1'-0"14 LAUNDRY ELEVATION 1 GENERAL NOTES B. Submit floor truss layouts showing beam locations, joist layout, locations of continuous duct chases, and maximum duct size in each chase. Allow designer five days for complete review. lumber package. Allow designer five days for complete review. manufacturer for review prior to ordering roof trusses and/or roof A. Submit roof truss and/or rafter layout plan as completed by the 12. SUBMITTALS 8. DOORS AND WINDOWS A. Exterior doors shall be selected by the Owner. B. House-to-garage doors shall be fire rated doors approved by governing codes. Face design to be selected by the Owner. C. Interior doors shall be selected by the Owner. D. Exterior windows by Pella Corp as selected by owner. E. Glazing in all doors and windows shall comply with governing codes. F. Install egress window units in accordance with governing codes. G. Door and window sizes indicated or drawings are as follows: "3/0x6/8" represents a door or window 3'-0" wide x 6'-8" high. Jamb depth to be coordinated by the Contractor. H. Finish hardware shall be selected by the owner. Install hardware in accordance with governing codes. 9. FINISHES A. Gypsum wallboard, unless noted otherwise, shall be provided as follows: 1. Exterior walls: One layer 1/2" regular wallboard to interior face. 2. Interior walls: One layer 1/2" regular wallboard each face. 3. Ceiling: One layer 5/8" regular wallboard. 4. Garage/House common wall: One layer 5/8" type "X" wallboard each face. 5. Baths: Water resistant wallboard at all walls and ceilings surrounding tubs and showers and as required by governing codes. Provide cement board as substrate for ceramic tile. B. Provide metal corner bead and trim at all locations recommended by the gypsum wallboard manufacturer. C. Tape, float, and sand joints and fasteners of gypsum wallboard with three coats of joint compound as required to obtain a uniformly smooth surface. D. Finishes shall be selected by the Owner. 10. PLUMBING, MECHANICAL, AND ELECTRICAL A. Plumbing, mechanical, and electrical information and layouts shown on the Drawings is schematic in design, and shall be reviewed by sub-contractors, suppliers, and building officials for compliance with governing codes and good common construction practices. The Architect shall be notified by the Contractor of any discrepancies prior to construction. B. Plumbing, mechanical, and electrical equipment shall be selected by the Owner. C. Design and installation of plumbing, mechanical, and electrical equipment shall be the responsibility of the appropriate licensed contractors and sub- contractors. Design shall be submitted for owner's review prior to ordering D. Service panels shall be selected by the electrical sub-contractor. E. All HVAC equipment shall be individually switched. F. All outdoor, bath, and garage and spa wall receptacles shall be provided with ground fault circuit protection in accordance with governing codes. G. Dryer vents shall be extended to the exterior. H. Provide plumbing vents in accordance with governing codes. Minimize number and locate for minimal visual impact. I. Install type and number of smoke detectors in accordance with governing codes & UL217. J. Connect water, gas, and electric services in accordance with governing codes. 11. MISCELLANEOUS and installation of equipment. exterior walls install plates over foam sill sealer. C. Unless noted otherwise, all slabs on grade shall be 4" thick, reinforced with 6x6 W1.4xW1.4 W.W.M., and placed over 4" minimum compacted sand or gravel fill. Interior slabs shall be placed over 6 mil. Stabilized polyethylene vapor barrier. Coordinate with radon removal procedures. D. Footing sizes shown are typical only for stated soil pressure and consistent compaction. Contractor shall be responsible for footings complying with A. Adhered masonry flashing must be installed at wall penetrations and terminations integrated with the WRB properly (when used), and installed in accordance with the to ensure a consistent overall project color on the wall. C. Install in accordance with manufacturer's installation instructions. Visit this page for http://ncmabr.org/pdfs/masterlibrary/MVMA%20Installation%20Guide%204th%20Edition%20web.pdf Consult manufacturer for proper installation instructions. modified mortar meeting ANSI A118.4 OR ANSI 118.15. F. Touch-up, repair or replace damaged stone before completion of project. A. All structural steel shall comply with appropriate ASTM Specifications as follows: ASTM A36, ASTM A53, ASTM A501, ASTM A307, and ASTM A. Lumber shall, in addition to complying with governing codes, comply with: 1. "Product Use Manual" of the Western Wood Products Association for selection and use of products included in that manual. 2. "Plywood Specification and Grade Guide" of the American Plywood 3. "Standard Specifications for Grades of California Redwood Lumber" of 4. American Wood Preservers Association standards and recommendations for fire-retardate and preservative pressure treated lumber and plywood. 5. Western Red Cedar Lumber Association standards and recommendations the Redwood Inspection Bureau for Redwood. for cedar. Association. D. Application details and mortar recommendations may vary depending on the stone style. E. All dry-stacked and large format standard stones must be applied using a polymer - 5. METALS A325. 6. WOOD AND PLASTICS the design requirements of specific soil conditions. of the stone veneer. Assure that all flashing and kickouts are corrosion resistant, local building code requirements. B. Product should be pulled from a variety of boxes and blended on site during intalllation installation instructions: 4. MASONRY Install skylights according to the manufactures' recommendations. I. Install water and ice barrier (Bituthene or equal) over roof sheathing at all eaves and valleys. water & ice barrier to extend 24" past outside face of L. Provide 2" nominal pressure treated lumber over foam sill sealer beneath full bearing of wood beams bearing on concrete or 7. THERMAL AND MOISTURE PROTECTION A. Provide thermal building insulation at assemblies adjacent to exterior or unheated spaces meeting the requirements of governing codes and, unless noted otherwise, meeting the following minimum requirements: 1. Foundations: 1 1/2"extruded polystyrene (R-10) 2. Walls: glass fiber batt (R-20) U.N.O. 3. Floors: glass fiber batt (R-30) -for floors over unconditioned space or exterior 4. Ceilings: glass fiber batt (R-49) 5. Install continuous blankets without holes for electrical boxes, lighting fixtures, or heating ductwork. B. Install 6 mil. stabilized polyethylene vapor barrier against interior face of all C. Waterproof foundation walls at excavated areas from footing to finished grade with two coats of asphalt based waterproofing compound for full basements. D. Roofing shall be 240 lb. (minimum) composition shingles installed over 15 lb. roof felt on roof sheathing. Minimum slope, fasteners, under layment, and exposure according to manufacturers' recommendations. E. Provide flashing and sheet metal required to prevent penetration of water through the exterior shell of the building. In addition to complying with governing codes, comply with pertinent recommendations contained in the current edition of "Architectural Sheet Metal Manual" published by SMCNA. All iron sheet metal flashing shall be hot-dipped galvanized complying with F. Provide gutters and downspouts to provide positive roof and site drainage. G. Provide attic and roof ventilation as required by governing codes and as shown on the Drawings. Provide appropriate soffit and roof vents. H. Skylights shall be selected by the Contractor and approved by the owner. ASTM A93. thermal insulation. masonry. 1. Before final Drawings and Specifications are issued for construction, they shall be submitted to all governing building agencies to insure their compliance with all applicable local and national codes. If code discrepancies in Drawings and/or Specifications appear, the Architect shall be notified of such discrepancies in writing by the Contractor or building official, and allowed to alter the drawings and specifications so as to comply with governing codes before construction begins. 2. Upon written receipt of approval from the governing official, approved final Drawings and Specifications shall be submitted to the Contractor by 3. If code discrepancies are discovered during the construction process, the Architect shall be notified and allowed ample time to remedy said 4. All work performed shall comply with all applicable local, state and national building codes, ordinances and regulations, and all other B. All contractors, suppliers, and fabricators shall be responsible for the content of the Drawings, and for the supply and design of appropriate C. All manufactured articles, materials, and equipment shall be handled, applied, installed, erected, used, cleaned, and conditioned in strict accordance with the D. All alternates are at the option of the Owner and shall be at the Owner's request, constructed in addition to or in lieu of the typical construction, as dead load 15psf (10 psf top, 5psf bottom) dead load 15psf (10 psf top, 5psf bottom) 5. Prior to start of construction, verify design loads with governing codes and site conditions. Check with local building agencies for wind, seismic, snow and other special loading conditions. If discrepancies are discovered, Architect shall be notified according to Section 1.A.1 above. A. Perform excavation, according to good common construction practices, to the lines, grades, and elevations indicated on the Drawings. B. Provide consistent compaction of the top 8" of sub-grade, fill, and backfill material beneath structures, walks, and pavements to meet the stated soil C. Provide soil poisoning to control termites as required by governing codes. D. Provide and install ventilation for Radon Gas as required by local building A. Provide concrete complying with ASTM C94. Unless otherwise noted, concrete shall have the following 28 day compressive strengths as minimums: 2. Concrete floor slabs, walks, drives, and patios: 3,500psi 3. Provide construction joints so panel size does not exceed 400sf. B. Provide reinforcement of the size and spacing indicated on Drawings. Reinforcing shall comply with the following minimums: live load 60psf (maximum) live load 40psf (maximum) live load 30psf (maximum) agencies and governing codes. 1. Concrete footings and foundations: 3,000psi 1. Bars: ASTM A615, grade 40, deformed bars. 2. Welded Wire Fabric: ASTM A185. 3. CONCRETE 2. SITE WORK pressure. materials and work performance. manufacturers' requirements. indicated on the Drawings. 3. Balconies and Decks: 4. Soil Pressure: 1500 psf (minimum) 2. Floor: 1. Roof: E. Design Loads: dead load 10psf 1. GENERAL REQUIREMENTS authorities having jurisdiction. discrepancies. the Architect. A. Codes: drawings to designer for review prior to construction. spacing of all trusses. Contractor to submit truss drawings and/or roof framing b. Install joist and beam hangers capable of supporting the maximum allowable load of joist or beam being supported. C. Provide "Micro-Lam" glue laminated veneer lumber beams (manufactured by Truss Joist Corporation) or equal, of the dimensions and number indicated on the drawings. Provide exterior grade Micro Lams for deck framing and other in strict accordance with manufacturers' recommendations. a. Modulus of elasticity: 2,000,000 psi b. Flexural (12" depth): 2,900 psi c. Horizontal shear: 285 psi D. Provide wood trusses able to sustain the stated loads for the spans, profiles, and arrangement shown on the Drawings. Truss layout is schematic only. Truss manufacturer and/or engineer shall be responsible for the design and E. All roof trusses shall be installed with metal truss seats as specified by the F. Unless noted otherwise, provide: 1. Double header joists and trimmers at all floor openings. 2. Double joists under all partitions parallel to joists. 3. Double 2x12 headers with 1/2 OSB between at all door and window openings in 2x4 walls. Triple 2x10 headers with 1/2" OSB between at all door and window openings at 2x6 walls. 4. For solid sawn joists, provide one row of 1x3 cross-bridging or metal bridging G. Stud spacing at all exterior and bearing walls shall be 16" o.c. minimum. H. Stud walls shall not exceed the following heights without continuous lateral support perpendicular to the plane of the wall at the stated height or less. Studs shall be continuous between points of lateral support. I. Unless noted otherwise, rafters, ceiling joists, collar ties, and purlins shall be sized and spaced in accordance with FHA requirements or governing codes, J. Stair construction shall consist of (3)2x12 stringers, 5/4" or 2x thick tread and 3/4" thick risers or, shall be fabricated by component manufacturer. K. All wood plates bearing on concrete or masonry shall be pressure treated. At b. 2x6: 12'-0' 2. Non-bearing walls: a. 2x4: 14'-0" b. 2x6: 20'-0" whichever is more restrictive. 1. Bearing walls: a. 2x4: 10'-0" for each 8'-0" of joist span. d. Bearing: 550 psi truss manufacturer. 1. Allowable stresses: B. Provide lumber and materials meeting or exceeding the following standards of a. Studs: Douglas Fir-Larch, Stud Grade -or as approved by building code. b. Headers and Beams: Douglas Fir-Larch, No. 2 and better -or as appoved by building code. 2. All headers and beams shall be free from splits, checks, and shakes. a. Roof: 1/2" OSB APA RATED SHEATHING, EXP 1. b. Walls: 1/2" OR 7/16" OSB APA RATED SHEATHING, EXP 1. c. Floor: 23/32" plywood APA RATED SHEATHING, EXP 1. d. Proper oriented strand board may be substituted for plywood. steel at exterior locations. a. Steel items: Comply with ASTM A36; use galvanized 3. Sheathing: (with clips) (glue and nail) 4. Rough Hardware: 1. Framing Members: quality: Contractor to submit steel shop drawings to designer or a licensed structural Construction and shall be detailed by a qualified structural steel detailer. B. All steel connections shall be designed according to AISC Manual of Steel engineer prior to steel erection. C. Architect will not be responsible for any errors in the roof and/or floor framing without the opportunity to review the roof and/or floor framing layouts. Framing layouts, member sizes, and floor/roof penetrations indicated on the drawings are for design intent only. Final layouts shall be the responsibility of builder. exterior applications. Unless noted otherwise, fasten multiple beams together exterior wall below. And as shown on the roof plan. A. This set of construction drawings is intended for design intent only. Although many jurisdictions will accept these drawings as sufficient for a construction permit, these drawings are not intended, and should not be construed, as a complete set of construction drawings. These drawings will have to be adapted to meet local zoning and/or site conditions and additional detailing will need to be completed on site by the builder. B. Install prefabricated fireplace units as shown on Drawings. 1. Fireplace units shall be "Heat-N-Glo" or as approved by Owner. 2. Contractor shall be responsible for proper installation as recommended by the manufacturer and as required by governing codes, including mantel and hearth design and location. C. Room sizes shown on the plans indicate room dimensions prior to installation of gypsum wall board. Gypsum wall board thickness must be subtracted from room sizes indicated for actual room dimensions and are subject to change. 2. Use exterior grade Micro-Lam in all areas subject to moisture. 3. Hearth shall be of non-combustible material. E. All excavations located beneath interior floor slabs (including garage) shall be inspected by a geotechnical engineer for bearing and the presence of unsuitable soils. If unsuitable soils are identified, the contractor shall follow the recommendations of the geotechnical engineer. F. All excavations located beneath footings and foundations shall be inspected by a geotechnical engineer for bearing and the presence of unsuitable soils. If unsuitable soils are identified, the contractor shall follow the recommendations of the geotechnical engineer. EARTH RIGID INSULATION CONCRETE BLOCK CONCRETE BRICK PLYWOOD STEEL OR STEEL STUD WALL BATT INSULATION GYPSUM BOARD GRAVEL WOOD OR WOOD STUD WALL SOUND INSULATION IN WALL MIN. (3) 2X SOLID BLOCKING BEARING WALL MATERIALS ELEVATION DRAWING NUMBER WALL TYPE SHEET NUMBER SHEET NUMBER SECTION DRAWING NUMBER DETAIL DRAWING NUMBER SHEET NUMBER POINT LOAD FROM ABOVE ELEVATION HEIGHT ELEVATION TYPE W2 SYMBOLS VINTAGE COOP PLAN INFORMATION PLAN OPTION: FOUNDATION: ROOF TRUSS: TUSCANY ESTATE SLAB ON GRADE UPPER FLOOR BONUS ROOM FULL BASEMENT STANDARD ROOF TRUSSES 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : IS S U E D F O R : 11 - 2 3 - 2 0 FO R C O N S T R U C T I O N 11 - 3 0 - 2 0 RE V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 RE V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 OW N E R R E Q U E S T E D C H A N G E S A0 19-137.2 3-18-2021 MS P L A N LR KC VI N T A G E E S T A T E S - N O R T H L I B E R T Y TU S C A N Y E S T A T E P L A N TI T L E S H E E T SHEET LIST Sheet Number Sheet Name A0 TITLE SHEET A100 FOUNDATION PLAN A101 MAIN FLOOR PLAN A200 ELEVATIONS A201 DETAILS AREA SCHEDULE Level Name Area MAIN FLOOR MAIN FLOOR 1394 SF MAIN FLOOR GARAGE 560 SF Grand total: 2 1954 SF NOTE: THIS DRAWING IS AN ARTISTIC INTERPRETATION OF THE GENERAL APPEARANCE OF THE DESIGN. IT IS NOT INTENDED TO BE AN EXACT RENDITION. MAIN FLOOR 0" T.O.F. -6" B.O.F. -4' -0" W3W2 ***VERIFY ALL CHANGES IN WALL ELEVATION ON SITE. MAINTAIN 42" MINIMUM FROST PROTECTION AT ALL TIMES ***ALL FOUNDATION STEP-DOWNS TO BE DETERMINED ON SITE AS GRADE ALLOWS DROP T.O.F. @ O.H.D., VERIFY W/ GRADE 4' - 0 " 8" 6" 3' - 2 " 8" 8"8" 1' - 4"1' - 4" W1 1' - 4" 6" 3' - 6 " 8" 8" CF16 10 " 1' - 4" W4 6" 3' - 8 " 8" 8" 1' - 4"MA I N T A I N 4 2 " F R O S T PR O T E C T I O N A T A L L T I M E S 2' - 10"16' - 4"2' - 2"6' - 4" NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL NOTE: STEP FOOTINGS DOWN AS GRADE REQUIRES. MAINTAIN MINIMUM FROST PROTECTION AT ALL TIMES. NOTE: STEP FOUNDATION DOWN AS GRADE REQUIRES. MAINTAIN 42" MINIMUM FROST PROTECTION ON ALL FOOTINGS NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL STOOP ABOVE NOTE: CHANGES IN FOOTING AND FOUNDATION WALL ELEVATIONS ARE FOR DESIGN INTENT ONLY. ACTUAL ELEVATIONS SHALL BE VERIFIED W/FINAL GRADE DURING CONSTRUCTION. MAINTAIN 42" MINIMUM FROST PROTECTION ON ALL FOOTINGS. STEP DOWN FOOTING @ O.H.D. 4 A201 STOOP ABOVE 41' - 0" W2 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 5' - 0 " 25 ' - 4 " 29 ' - 0 " 5' - 8 " 65 ' - 0 " 9' - 0"13' - 0"19' - 0" 41' - 0" NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL W4 W4 W4 W4 W4 W2 W2 W3 W1 W1 8" 27' - 0" 8" 2' - 0"10' - 0" 8" 8"20' - 9 1/2"8"5' - 6 1/2"12' - 8"8" 5' - 0 " 7' - 0 " 27 ' - 0 " 11 ' - 8 " 14 ' - 4 " 65 ' - 0 " 18' - 2 1/2" 13' - 4" 5' - 0" W1 TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL 21' - 4"19' - 8" 135.00° W1 -VERIFY ALL CHANGES IN WALL ELEVATION ON SITE -MAINTAIN 42" MINIMUM FROST PROTECTION AT ALL TIMES POST P20 FOOTING F30 F24 CF16 1'-8'' 2'-6'' 2'-0'' 1'-4'' DIA 2'-6'' 2'-0'' CONT 4'-0'' 1'-0'' 1'-0'' 10'' (2) #4 CONT. #4 AT 12" O.C. E.W. #4 AT 12" O.C. E.W. (2) #4 CONT. -NOT ALL TYPES ARE USED F36 3'-0'' 3'-0'' 1'-0'' #4 AT 12" O.C. E.W. 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A100 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y TU S C A N Y E S T A T E P L A N FO U N D A T I O N P L A N SCALE: 1/4" = 1'-0"2 FOOTING LEGEND SCALE: 1/4" = 1'-0"1 FOUNDATION PLAN FOUNDATION SCHEDULE Type Mark WALL FOOTING Width Unconnected Height Hotizontal Reinforcements Vertical Reinforcements Footing Width Footing Length Footing Depth Footing Reinforcing W1 8" 3' - 6" #4 @ TOP & BOT. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. W2 8" 4' - 0" #4 @ TOP & BOT. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. W3 8" 3' - 2" #4 @ TOP & BOT. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. W4 8" 3' - 8" #4 @ TOP & BOT. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. 4 A201 22' - 0"5' - 0"14' - 0" 14 ' - 4 " 11 ' - 8 " 7' - 0 " 6' - 6 " 5' - 4 1 / 2 " 4' - 3 " 10 ' - 1 0 1 / 2 " 5' - 0 " 3' - 0"16' - 0"3' - 0"2' - 6"2' - 6"7' - 0"7' - 0" W W.C. COVERED PORCH R/S R/ S R/S MUD/LAUN. MASTER BEDROOM BATH GUEST BEDROOM TWO CAR GARAGE 41' - 0" M. BATH M. CLOSET LOCKERS W.C. 65 ' - 0 " 3/0 x 6/8 PCKT 2/8 x 6/8 2/ 8 x 6 / 8 2/8 x 6/8 3/ 0 x 6 / 8 3/ 0 x 6 / 8 2/10 X 6/8 2/ 1 0 X 6 / 8 3/ 0 X 6 / 8 KITCHEN DINING 3' - 9"5' - 3"13' - 0"6' - 4"12' - 8" 41' - 0" 5' - 0 " 25 ' - 4 " 5' - 7 " 2' - 2 1 / 2 " 8' - 8 " 6' - 0 1 / 2 " 6' - 6 " 5' - 8 " 65 ' - 0 " FOYER GUEST CLOSET PLUMBING WALL AS REQ'D FOR W/D HOOKUPS 29 3 5 C S M T 2959 CSMT 2959 CSMT 29 5 9 C S M T 1' - 1 0 " 4' - 8 " 6" 3' - 3"3' - 3"10' - 1 1/2"4' - 4 1/2"6' - 4"6" R/S 2' - 3"8' - 6"2' - 3" 2' - 0 " 4' - 6 " 5' - 2 " 9' - 2 " 5' - 2 " G.T.A.EX. GRADE LVL BM ABOVE EX . G R A D E L V L B M A B O V E 2' - 11"3' - 5"2' - 0"5' - 0"5' - 8" 32 X 6 0 TU B / S H W R 72 8 2 S L D R EX. GRADE LVL BM ABOVE (2) 1 3/4 X 11 7/8 LVL HEADER ATTIC ACCESS ABOVE ROOF TRUSS ABV. @ 24" O.C. 2/ 1 0 X 6 / 8 RO O F T R U S S A B V . @ 2 4 " O . C . NOTE: WALLS AND CEILING TO BE FINISHED W/ 5/8" TYPE "X" FIRE CODE GYPSUM BOARD SL O P E S L A B 6 " T O OV E R H E A D D O O R RO O F T R U S S A B V . @ 2 4 " O . C . 3- LIVING ROOM BRG WALL 2959 CSMT3- 2' - 0 " 6"12' - 9 1/2"8' - 2 1/2"5 1/2"18' - 6 1/2" 21' - 0"5 1/2"5' - 3"2' - 6 1/2"3' - 10 1/2"6' - 10 1/2"6" 3/0 x 6/8 MECH. D 13' - 6" 6' - 6"14' - 8"6' - 2"6" NOTE: DIMENSIONS AND ROOM SIZES ARE SHOWN FOR DESIGN INTENT ONLY. DUE TO CONSTRUCTION MEANS, METHODS AND TOLERANCES, ROOM SIZES ARE SUBJECT TO CHANGE WITHOUT NOTICE. 25 ' - 3 1 / 2 " 7' - 4 " 13 ' - 1 0 " 12 ' - 6 1 / 2 " 6" 3' - 3"5' - 5 1/2" BEAR TRUSSES ON GARAGE/HOUSE WALL OPTIONAL POCKET DOOR 12" TRAY CLG. OPTIONAL 12" TRAY OPTIONAL POCKET DOOR HB HB NICHE FURNWH FLOOR DRAIN 2 A201 Sim 3 A201 Sim R/ S 13 ' - 3 1 / 2 " 3' - 0 1 / 2 " 2' - 4 " 3' - 1 1 1 / 2 " 3' - 4 1 / 2 " 1 3 5 . 0 0 ° 2' - 0" 2' - 0 " 2' - 6 " 3' - 6 " 5' - 4 " 8 1 / 2 " 2959 CSMT 135.00°3559 CSMT2- 2/ 0 x 6 / 8 1/4 X 6/8 1 1/2" 0'-0" -0'-2" 2' - 0 " 2' - 0" 2' - 0 " 2' - 0" PA N T R Y CL LIN. CLO. 29 2 9 T R S M 29 5 9 C S M T 29 5 9 C S M T A101 3 FULL HT. WALL PA N T R Y O.H.C. O. H . C . RA N G E REF DW SI N K A201 8 A201 9 A2015 6 7 (2) 1 3/4x11 7/8 LVL HDR LAV. LAV.LAV. MW H O O D COVERED PORCH RIDGEVALLEYVALLEYRI D G E RI D G EVALLEYRI D G E ROOF NOTES: 2'-0" EAVE OVERHANG*** 1' - 6" GABLE RAKES*** 10:12 SLOPE SIDE TO SIDE*** 8:12 SLOPE FRONT TO BACK*** ***UNLESS NOTED OTHERWISE PROVIDE RIDGE, HIP AND SOFFIT VENTING TO COMPLY W/ GOVERNING CODES SNOW AND ICE BARRIER ALONG ALL EAVES & RAKES 2' - 0" PAST OUTSIDE FACE OF FRAMING (TYPICAL @ ALL EXTERIOR EAVES) OUTSIDE FACE OF FRAMING BELOW 2' - 0" 1' - 6 " 2' - 0" 2' - 0" 2' - 0" RI D G E 2' - 0" 1' - 6"VALLEYRI D G E 1' - 6" OVERFRAMING AS REQ'D (TYPICAL SEE ELEVATIONS) 1' - 6" 2' - 0" 1' - 6 " 1' - 6 " 6" / 12"6" / 12" 6" / 12" 6" / 1 2 " 6" / 1 2 " 2' - 0 " 2' - 0 " 2' - 0 "VALLEYVALLEY6" / 12"6" / 12" 6" / 12"6" / 12" 6" / 12"6" / 12" 1' - 6" 1' - 6" 1' - 6 " 1' - 6 5 / 8 " 2' - 0 " 2' - 2 5/8"2' - 2 5/8" 2' - 0 " OP T . FP 29 2 9 T R S M 29 2 9 T R S M 2' - 0 " 9' - 0 " 2' - 6 " 13 ' - 6 " 2' - 0 " 2' - 0 " 5' - 0 " 2' - 0 " 2' - 0 " SEE PLAN FOR WINDOW SIZE/DIMS 13 ' - 0 " 2' - 0" LIVING ROOM 12" TRAY CLG. REF. SI N K DW RA N G E MW H O O D PA N T R Y 2' - 3"2' - 6"2' - 0"3' - 0" 9' - 9" 1" 1' - 0 " 1' - 0 " 2' - 0 " 2' - 3 " 1" 2' - 6 " 2' - 6 " 3' - 0 " 3' - 0 " 1 1 / 2 " 13 ' - 5 1 / 2 " 2 1 / 2 " 1' - 3 " 3' - 0 " 3" 2' - 0 " 3" 2 1/4"2' - 0"1' - 1 3/4" 3' - 4" O. H . C . O . H . C .O.H.C.O.H.C. O.H.C. O.H.C. 6' - 1 1 1 / 2 " 3' - 0" 1' - 1 0 1 / 2 " 1' - 6"1' - 6" 5' - 1" 1/2" 1' - 0 1/4"2' - 11 1/2"1' - 0 1/4" 1/2" 1' - 1 0 1 / 2 " 1' - 1 0 1 / 2 " 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A101 19-137.2 3-18-2021 MS P L A N ML K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y TU S C A N Y E S T A T E P L A N MA I N F L O O R P L A N SCALE: 1/4" = 1'-0"1 MAIN FLOOR- 1380 FLOOR PLAN SCALE: 1/4" = 1'-0"2 ROOF PLAN SCALE: 1/4" = 1'-0"3 FIREPLACE OPTION SCALE: 3/8" = 1'-0"4 TUSCANY KITCHEN SCALE: 3/8" = 1'-0"5 TUSCANY BATH SCALE: 3/8" = 1'-0"6 TUSCANY MASTER BATH MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MAIN WIN. H.H. 6' -10" S3 T5 CONCRETE - SLOPE TO GRADE AS REQ'D L19' - 1 1 / 8 " T1 M2 M1 R1 C1 R1 T4 F1 F1 T1 M2 M1 T7 T4 F1 T7 T6 3525 CSMT 3525 FXD T7 S4 T1 S4 T5 T2 4' - 0 " 3' - 4 " R1 S1 T1 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE T2 S3 S3T5 S3 S1 T1 T5 T2 R1 C1 M1 M1M2 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MAIN WIN. H.H. 6' -10" T1 S1 T5 T2 R1 F1 S4 C1 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE FIREPLACE OPTION B TRANSOM WINDOWS 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A200 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y TU S C A N Y E S T A T E P L A N EL E V A T I O N S SCALE: 1/4" = 1'-0"1 FRONT SCALE: 1/4" = 1'-0"2 BACK SCALE: 1/8" = 1'-0"3 LEFT SCALE: 1/8" = 1'-0"4 RIGHT Keynote Legend Key Value Keynote Text C1 COLUMN WRAP - OR - TRIM OUT COLUMN F1 6" ALUMINUM FASCIA OR 6" ALUMINUM RAKE L1 EXTERIOR WALL LIGHT M1 MASONRY- CULTURED STONE M2 MASONRY- STONE CAP R1 LAMINATED ASPHALT ROOF SHINGLES S1 (LAP SIDING) HARDIE-PLANK SIDING-7" MAX EXPOSURE S3 (BOARD AND BATTEN SIDING) VERTICAL SIDING AND HARDIE TRIM S4 (SHAKE SIDING) T1 PAINTED HARDIE CORNER TRIM T2 4" PAINTED TRIM T4 6" OVER 8" PAINTED TRIM T5 7" OVER 12" PAINTED TRIM T6 5/4 X 7" PAINTED TRIM T7 4" TRIM AT WINDOWS ON FRONT ELEVATION ONLY 1X3 BATTENS ON SMOOTH PANEL SIDING MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" T.O.F. -6" B.O.F. -4' -0" 8' - 1 1 / 4 " 2" 11 7 / 8 " 8' - 1 1 / 4 " 2" 11 1/4"TREATED STAINED TIMBER COLUMN BUILT UP TRIM FOUNDATION WALL SEE FOUNDATION PLAN STONE CAP SEE ROOF PLAN 36" PLASTIC ATTIC CHUTE SNOW AND ICE BARRIER EXTEND 24" PAST I.S. FACE OF EXTERIOR WALLS LAMINATED ASPHALT ROOF SHINGLES ON 15# ROOF FELT ON 1/2" O.S.B. SHEATHING MTL. DRIP 2X6 SUB-FASCIA 3/8" VENTED ALUMINUM SOFFIT & FASCIA ON 2X4 LOOKOUTS @ 24" O.C. 7" OVER 12" PAINTED TRIM SEE ELEVATIONS FOR SIDING MATERIAL WEATHER RESISTANT BARRIER OVER 1/2" O.S.B. SHEATHING ON 2X6 WALL STUDS @16" O.C. R21 INSULATION 1/2" GYP. BD. ON 6MIL POLY VAPOR BARRIER FLASHING (ALL HORIZ. JOINTS) 2X6 SILL PLATE "TRTD" ON CLOSED CELL FOAM SILL SEALER R49 BLOWN INSULATION 12 SE E R O O F PL A N MAIN FLOOR 12 " E N E R G Y H E E L M I N . T.O.F. 0'-0" 0'-4" FOUNDATION WALL-REFER TO PLAN TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL MAIN FLOOR PLT. HT. 9'-1 1/8" HOLD ALL TRIM AND SIDING MIN. 6" ABOVE GRADE 9' - 1 1 / 8 " CONTINUOUS BEAD OF SEALANT 4"4" 4' - 0 " LINE OF GRADE (VARIES) 2" 4" 2' - 0" HOLD ALL TRIM AND SIDING MIN. 6" MIN. ABOVE GRADE MAIN FLOOR 0'-0" TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL CONTINUOUS BEAD OF SEALANT 4"4" 2" 4" 2' - 0"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE GARAGE SLAB (SLOPE TO OVERHEAD DOOR) MAIN FLOOR 0'-0" TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL CONTINUOUS BEAD OF SEALANT 4"4" 2" 2' - 0"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE SLAB (SLOPE AWAY FROM HOUSE) MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8"1 1/2"3' - 0"3' - 0"2' - 6"2' - 6" 11' - 1 1/2" 7' - 6 " 9' - 1 1 / 8 " RANGE MW HOOD 1' - 4 9 / 1 6 " 2 9 / 1 6 " 3' - 0 " 1' - 6 " 3' - 0 " 1"3' - 0 1/2"2 1/2"2' - 9"2' - 7"2' - 0 1/2"MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" REF. 2' - 6"2' - 0"3' - 0" 7' - 6" 2 9 / 1 6 " 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 7' - 6 " 2' - 9"1' - 3" MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" DW 1' - 3"3' - 0" 3" 2' - 0" 3"6' - 9" 1 1 / 2 " 2' - 1 0 1 / 2 " 3' - 0 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 5' - 0"1/2"1/2" 5' - 1" 4" 1 1 / 2 " 2' - 1 0 1 / 2 " 3' - 0 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 3' - 0" 1 1 / 2 " 2' - 1 0 1 / 2 " 3' - 0 " 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A201 19-137.2 3-18-2021 MS P L A N ML K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y TU S C A N Y E S T A T E P L A N DE T A I L S DOOR SCHEDULE Type To Room: Name Door CommentsWidth Height 2/10 X 6/8 BATH 2' - 10" 6' - 8" 1/4 x 6/8 BATH 1' - 4" 6' - 8" 7282 SLDR DINING 6' - 0" 6' - 10" 3/0 X 6/8 FOYER 3' - 0" 6' - 10" 2/10 X 6/8 FOYER 2' - 10" 6' - 8" 2/0 x 6/8 FOYER 2' - 0" 6' - 8" 2/10 X 6/8 GUEST BEDROOM 2' - 10" 6' - 8" 2/8 x 6/8 M. BATH 2' - 8" 6' - 8" Interior - Double Sliding Glass Shower Door M. BATH 5' - 0" 6' - 0" 2/8 x 6/8 M. CLOSET 2' - 8" 6' - 8" 3/0 x 6/8 MASTER BEDROOM 3' - 0" 6' - 8" 3/0 x 6/8 MECH. 3' - 0" 6' - 8" 3/0 x 6/8 MUD/LAUN. 3' - 0" 6' - 8" 3/0 x 6/8 PCKT MUD/LAUN. 3' - 0" 6' - 8" 2/8 x 6/8 MUD/LAUN. 2' - 8" 6' - 8" 16'-0" x 8'-0" TWO CAR GARAGE 16' - 0" 8' - 0" NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL DOORS PRIOR TO BIDDING AND CONSTRUCTION NOTE: VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION WINDOW SCHEDULE From Room: Name Type Comments 2929 TRSM 2959 CSMT E 2959 CSMT E DINING 2929 TRSM DINING 2959 CSMT E DINING 3559 CSMT E DINING 3559 CSMT E GUEST BEDROOM 2959 CSMT E GUEST BEDROOM 2959 CSMT E GUEST BEDROOM 2959 CSMT E GUEST BEDROOM 3525 FXD SMALL GABLE M. BATH 2935 CSMT E3 MASTER BEDROOM 2959 CSMT E MASTER BEDROOM 2959 CSMT E MASTER BEDROOM 2959 CSMT E MASTER BEDROOM 2959 CSMT E MASTER BEDROOM 2959 CSMT E MUD/LAUN. 2929 TRSM TWO CAR GARAGE 3525 FXD GARAGE GABLE Grand total: 19 NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL WINDOWS PRIOR TO BIDDING AND CONSTRUCTION NOTE: VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION NOTE: GLASS SHOWER DOORS NOT INCLUDED IN SCHEDULE SCALE: 1/2" = 1'-0"4 TYP. COLUMN ROOM FINISH SCHEDULE- OVERALL ROOM NO ROOM NAME AREA FLOOR BASE WALLS CEILING NOTESN E S W FINISH HEIGHT 1 GUEST BEDROOM 131 SF CARPET 2 BATH 53 SF LVT 3 MASTER BEDROOM 151 SF CARPET 4 MUD/LAUN. 87 SF LVP 5 TWO CAR GARAGE 522 SF CONCRETE 6 M. BATH 92 SF LVT 7 M. CLOSET 53 SF CARPET 8 KITCHEN 136 SF LVP 9 DINING 367 SF LVP 10 PANTRY Not Placed LVP 11 GUEST CLOSET 26 SF CARPET 13 LOFT 623 SF 14 FOYER 92 SF LVP 15 LIVING ROOM Redundant Room LVP 16 MECH. 55 SF CONCRETE 17 CL 6 SF LVP 18 LIN. CLO. 5 SF LVT NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL FINISHES PRIOR TO BIDDING AND CONSTRUCTION SCALE: 1/2" = 1'-0"1 TYPICAL SLAB ON GRADE WALL SECTION SCALE: 1" = 1'-0"2 TYP. ZERO ENTRY DETAIL - GARAGE SCALE: 1" = 1'-0"3 TYP. ZERO ENTRY DETAIL - STOOP SCALE: 1/4" = 1'-0"5 KITCHEN ELEVATION 1 SCALE: 1/4" = 1'-0"6 KITCHEN ELEVATION 2 SCALE: 1/4" = 1'-0"7 KITCHEN ELEVATION 3 SCALE: 1/4" = 1'-0"8 MASTER BATH ELEVATION SCALE: 1/4" = 1'-0"9 BATH ELEVATION SCALE: 1" = 1'-0"10 TERMITE GUARD GENERAL NOTES B. Submit floor truss layouts showing beam locations, joist layout, locations of continuous duct chases, and maximum duct size in each chase. Allow designer five days for complete review. lumber package. Allow designer five days for complete review. manufacturer for review prior to ordering roof trusses and/or roof A. Submit roof truss and/or rafter layout plan as completed by the 12. SUBMITTALS 8. DOORS AND WINDOWS A. Exterior doors shall be selected by the Owner. B. House-to-garage doors shall be fire rated doors approved by governing codes. Face design to be selected by the Owner. C. Interior doors shall be selected by the Owner. D. Exterior windows by Pella Corp as selected by owner. E. Glazing in all doors and windows shall comply with governing codes. F. Install egress window units in accordance with governing codes. G. Door and window sizes indicated or drawings are as follows: "3/0x6/8" represents a door or window 3'-0" wide x 6'-8" high. Jamb depth to be coordinated by the Contractor. H. Finish hardware shall be selected by the owner. Install hardware in accordance with governing codes. 9. FINISHES A. Gypsum wallboard, unless noted otherwise, shall be provided as follows: 1. Exterior walls: One layer 1/2" regular wallboard to interior face. 2. Interior walls: One layer 1/2" regular wallboard each face. 3. Ceiling: One layer 5/8" regular wallboard. 4. Garage/House common wall: One layer 5/8" type "X" wallboard each face. 5. Baths: Water resistant wallboard at all walls and ceilings surrounding tubs and showers and as required by governing codes. Provide cement board as substrate for ceramic tile. B. Provide metal corner bead and trim at all locations recommended by the gypsum wallboard manufacturer. C. Tape, float, and sand joints and fasteners of gypsum wallboard with three coats of joint compound as required to obtain a uniformly smooth surface. D. Finishes shall be selected by the Owner. 10. PLUMBING, MECHANICAL, AND ELECTRICAL A. Plumbing, mechanical, and electrical information and layouts shown on the Drawings is schematic in design, and shall be reviewed by sub-contractors, suppliers, and building officials for compliance with governing codes and good common construction practices. The Architect shall be notified by the Contractor of any discrepancies prior to construction. B. Plumbing, mechanical, and electrical equipment shall be selected by the Owner. C. Design and installation of plumbing, mechanical, and electrical equipment shall be the responsibility of the appropriate licensed contractors and sub- contractors. Design shall be submitted for owner's review prior to ordering D. Service panels shall be selected by the electrical sub-contractor. E. All HVAC equipment shall be individually switched. F. All outdoor, bath, and garage and spa wall receptacles shall be provided with ground fault circuit protection in accordance with governing codes. G. Dryer vents shall be extended to the exterior. H. Provide plumbing vents in accordance with governing codes. Minimize number and locate for minimal visual impact. I. Install type and number of smoke detectors in accordance with governing codes & UL217. J. Connect water, gas, and electric services in accordance with governing codes. 11. MISCELLANEOUS and installation of equipment. exterior walls install plates over foam sill sealer. C. Unless noted otherwise, all slabs on grade shall be 4" thick, reinforced with 6x6 W1.4xW1.4 W.W.M., and placed over 4" minimum compacted sand or gravel fill. Interior slabs shall be placed over 6 mil. Stabilized polyethylene vapor barrier. Coordinate with radon removal procedures. D. Footing sizes shown are typical only for stated soil pressure and consistent compaction. Contractor shall be responsible for footings complying with A. Adhered masonry flashing must be installed at wall penetrations and terminations integrated with the WRB properly (when used), and installed in accordance with the to ensure a consistent overall project color on the wall. C. Install in accordance with manufacturer's installation instructions. Visit this page for http://ncmabr.org/pdfs/masterlibrary/MVMA%20Installation%20Guide%204th%20Edition%20web.pdf Consult manufacturer for proper installation instructions. modified mortar meeting ANSI A118.4 OR ANSI 118.15. F. Touch-up, repair or replace damaged stone before completion of project. A. All structural steel shall comply with appropriate ASTM Specifications as follows: ASTM A36, ASTM A53, ASTM A501, ASTM A307, and ASTM A. Lumber shall, in addition to complying with governing codes, comply with: 1. "Product Use Manual" of the Western Wood Products Association for selection and use of products included in that manual. 2. "Plywood Specification and Grade Guide" of the American Plywood 3. "Standard Specifications for Grades of California Redwood Lumber" of 4. American Wood Preservers Association standards and recommendations for fire-retardate and preservative pressure treated lumber and plywood. 5. Western Red Cedar Lumber Association standards and recommendations the Redwood Inspection Bureau for Redwood. for cedar. Association. D. Application details and mortar recommendations may vary depending on the stone style. E. All dry-stacked and large format standard stones must be applied using a polymer - 5. METALS A325. 6. WOOD AND PLASTICS the design requirements of specific soil conditions. of the stone veneer. Assure that all flashing and kickouts are corrosion resistant, local building code requirements. B. Product should be pulled from a variety of boxes and blended on site during intalllation installation instructions: 4. MASONRY Install skylights according to the manufactures' recommendations. I. Install water and ice barrier (Bituthene or equal) over roof sheathing at all eaves and valleys. water & ice barrier to extend 24" past outside face of L. Provide 2" nominal pressure treated lumber over foam sill sealer beneath full bearing of wood beams bearing on concrete or 7. THERMAL AND MOISTURE PROTECTION A. Provide thermal building insulation at assemblies adjacent to exterior or unheated spaces meeting the requirements of governing codes and, unless noted otherwise, meeting the following minimum requirements: 1. Foundations: 1 1/2"extruded polystyrene (R-10) 2. Walls: glass fiber batt (R-20) U.N.O. 3. Floors: glass fiber batt (R-30) -for floors over unconditioned space or exterior 4. Ceilings: glass fiber batt (R-49) 5. Install continuous blankets without holes for electrical boxes, lighting fixtures, or heating ductwork. B. Install 6 mil. stabilized polyethylene vapor barrier against interior face of all C. Waterproof foundation walls at excavated areas from footing to finished grade with two coats of asphalt based waterproofing compound for full basements. D. Roofing shall be 240 lb. (minimum) composition shingles installed over 15 lb. roof felt on roof sheathing. Minimum slope, fasteners, under layment, and exposure according to manufacturers' recommendations. E. Provide flashing and sheet metal required to prevent penetration of water through the exterior shell of the building. In addition to complying with governing codes, comply with pertinent recommendations contained in the current edition of "Architectural Sheet Metal Manual" published by SMCNA. All iron sheet metal flashing shall be hot-dipped galvanized complying with F. Provide gutters and downspouts to provide positive roof and site drainage. G. Provide attic and roof ventilation as required by governing codes and as shown on the Drawings. Provide appropriate soffit and roof vents. H. Skylights shall be selected by the Contractor and approved by the owner. ASTM A93. thermal insulation. masonry. 1. Before final Drawings and Specifications are issued for construction, they shall be submitted to all governing building agencies to insure their compliance with all applicable local and national codes. If code discrepancies in Drawings and/or Specifications appear, the Architect shall be notified of such discrepancies in writing by the Contractor or building official, and allowed to alter the drawings and specifications so as to comply with governing codes before construction begins. 2. Upon written receipt of approval from the governing official, approved final Drawings and Specifications shall be submitted to the Contractor by 3. If code discrepancies are discovered during the construction process, the Architect shall be notified and allowed ample time to remedy said 4. All work performed shall comply with all applicable local, state and national building codes, ordinances and regulations, and all other B. All contractors, suppliers, and fabricators shall be responsible for the content of the Drawings, and for the supply and design of appropriate C. All manufactured articles, materials, and equipment shall be handled, applied, installed, erected, used, cleaned, and conditioned in strict accordance with the D. All alternates are at the option of the Owner and shall be at the Owner's request, constructed in addition to or in lieu of the typical construction, as dead load 15psf (10 psf top, 5psf bottom) dead load 15psf (10 psf top, 5psf bottom) 5. Prior to start of construction, verify design loads with governing codes and site conditions. Check with local building agencies for wind, seismic, snow and other special loading conditions. If discrepancies are discovered, Architect shall be notified according to Section 1.A.1 above. A. Perform excavation, according to good common construction practices, to the lines, grades, and elevations indicated on the Drawings. B. Provide consistent compaction of the top 8" of sub-grade, fill, and backfill material beneath structures, walks, and pavements to meet the stated soil C. Provide soil poisoning to control termites as required by governing codes. D. Provide and install ventilation for Radon Gas as required by local building A. Provide concrete complying with ASTM C94. Unless otherwise noted, concrete shall have the following 28 day compressive strengths as minimums: 2. Concrete floor slabs, walks, drives, and patios: 3,500psi 3. Provide construction joints so panel size does not exceed 400sf. B. Provide reinforcement of the size and spacing indicated on Drawings. Reinforcing shall comply with the following minimums: live load 60psf (maximum) live load 40psf (maximum) live load 30psf (maximum) agencies and governing codes. 1. Concrete footings and foundations: 3,000psi 1. Bars: ASTM A615, grade 40, deformed bars. 2. Welded Wire Fabric: ASTM A185. 3. CONCRETE 2. SITE WORK pressure. materials and work performance. manufacturers' requirements. indicated on the Drawings. 3. Balconies and Decks: 4. Soil Pressure: 1500 psf (minimum) 2. Floor: 1. Roof: E. Design Loads: dead load 10psf 1. GENERAL REQUIREMENTS authorities having jurisdiction. discrepancies. the Architect. A. Codes: drawings to designer for review prior to construction. spacing of all trusses. Contractor to submit truss drawings and/or roof framing b. Install joist and beam hangers capable of supporting the maximum allowable load of joist or beam being supported. C. Provide "Micro-Lam" glue laminated veneer lumber beams (manufactured by Truss Joist Corporation) or equal, of the dimensions and number indicated on the drawings. Provide exterior grade Micro Lams for deck framing and other in strict accordance with manufacturers' recommendations. a. Modulus of elasticity: 2,000,000 psi b. Flexural (12" depth): 2,900 psi c. Horizontal shear: 285 psi D. Provide wood trusses able to sustain the stated loads for the spans, profiles, and arrangement shown on the Drawings. Truss layout is schematic only. Truss manufacturer and/or engineer shall be responsible for the design and E. All roof trusses shall be installed with metal truss seats as specified by the F. Unless noted otherwise, provide: 1. Double header joists and trimmers at all floor openings. 2. Double joists under all partitions parallel to joists. 3. Double 2x12 headers with 1/2 OSB between at all door and window openings in 2x4 walls. Triple 2x10 headers with 1/2" OSB between at all door and window openings at 2x6 walls. 4. For solid sawn joists, provide one row of 1x3 cross -bridging or metal bridging G. Stud spacing at all exterior and bearing walls shall be 16" o.c. minimum. H. Stud walls shall not exceed the following heights without continuous lateral support perpendicular to the plane of the wall at the stated height or less. Studs shall be continuous between points of lateral support. I. Unless noted otherwise, rafters, ceiling joists, collar ties, and purlins shall be sized and spaced in accordance with FHA requirements or governing codes, J. Stair construction shall consist of (3)2x12 stringers, 5/4" or 2x thick tread and 3/4" thick risers or, shall be fabricated by component manufacturer. K. All wood plates bearing on concrete or masonry shall be pressure treated. At b. 2x6: 12'-0' 2. Non-bearing walls: a. 2x4: 14'-0" b. 2x6: 20'-0" whichever is more restrictive. 1. Bearing walls: a. 2x4: 10'-0" for each 8'-0" of joist span. d. Bearing: 550 psi truss manufacturer. 1. Allowable stresses: B. Provide lumber and materials meeting or exceeding the following standards of a. Studs: Douglas Fir-Larch, Stud Grade -or as approved by building code. b. Headers and Beams: Douglas Fir -Larch, No. 2 and better -or as appoved by building code. 2. All headers and beams shall be free from splits, checks, and shakes. a. Roof: 1/2" OSB APA RATED SHEATHING, EXP 1. b. Walls: 1/2" OR 7/16" OSB APA RATED SHEATHING, EXP 1. c. Floor: 23/32" plywood APA RATED SHEATHING, EXP 1. d. Proper oriented strand board may be substituted for plywood. steel at exterior locations. a. Steel items: Comply with ASTM A36; use galvanized 3. Sheathing: (with clips) (glue and nail) 4. Rough Hardware: 1. Framing Members: quality: Contractor to submit steel shop drawings to designer or a licensed structural Construction and shall be detailed by a qualified structural steel detailer. B. All steel connections shall be designed according to AISC Manual of Steel engineer prior to steel erection. C. Architect will not be responsible for any errors in the roof and/or floor framing without the opportunity to review the roof and/or floor framing layouts. Framing layouts, member sizes, and floor/roof penetrations indicated on the drawings are for design intent only. Final layouts shall be the responsibility of builder. exterior applications. Unless noted otherwise, fasten multiple beams together exterior wall below. And as shown on the roof plan. A. This set of construction drawings is intended for design intent only. Although many jurisdictions will accept these drawings as sufficient for a construction permit, these drawings are not intended, and should not be construed, as a complete set of construction drawings. These drawings will have to be adapted to meet local zoning and/or site conditions and additional detailing will need to be completed on site by the builder. B. Install prefabricated fireplace units as shown on Drawings. 1. Fireplace units shall be "Heat-N-Glo" or as approved by Owner. 2. Contractor shall be responsible for proper installation as recommended by the manufacturer and as required by governing codes, including mantel and hearth design and location. C. Room sizes shown on the plans indicate room dimensions prior to installation of gypsum wall board. Gypsum wall board thickness must be subtracted from room sizes indicated for actual room dimensions and are subject to change. 2. Use exterior grade Micro-Lam in all areas subject to moisture. 3. Hearth shall be of non-combustible material. E. All excavations located beneath interior floor slabs (including garage) shall be inspected by a geotechnical engineer for bearing and the presence of unsuitable soils. If unsuitable soils are identified, the contractor shall follow the recommendations of the geotechnical engineer. F. All excavations located beneath footings and foundations shall be inspected by a geotechnical engineer for bearing and the presence of unsuitable soils. If unsuitable soils are identified, the contractor shall follow the recommendations of the geotechnical engineer. EARTH RIGID INSULATION CONCRETE BLOCK CONCRETE BRICK PLYWOOD STEEL OR STEEL STUD WALL BATT INSULATION GYPSUM BOARD GRAVEL WOOD OR WOOD STUD WALL SOUND INSULATION IN WALL MIN. (3) 2X SOLID BLOCKING BEARING WALL MATERIALS ELEVATION DRAWING NUMBER WALL TYPE DECORATIVE COLUMN TYPE SHEET NUMBER SHEET NUMBER SECTION DRAWING NUMBER DETAIL DRAWING NUMBER SHEET NUMBER POINT LOAD FROM ABOVE ELEVATION HEIGHT ELEVATION TYPE W2 C1 SYMBOLS 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : IS S U E D F O R : 11 - 2 3 - 2 0 FO R C O N S T R U C T I O N 11 - 3 0 - 2 0 RE V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 RE V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 OW N E R R E Q U E S T E D C H A N G E S A0 19-137.2 3-18-2021 MS P L A N LR KC VI N T A G E E S T A T E S - N O R T H L I B E R T Y VE N E T O E S T A T E P L A N TI T L E S H E E T SHEET LIST Sheet Number Sheet Name A0 TITLE SHEET A100 FOUNDATION PLAN A102 MAIN FLOOR PLAN A200 ELEVATIONS A201 DETAILS AREA SCHEDULE Level Name Area MAIN FLOOR MAIN LEVEL 1769 SF MAIN FLOOR GARAGE 555 SF MAIN FLOOR: 2 2324 SF Grand total: 2 2324 SF NOTE: THIS DRAWING IS AN ARTISTIC INTERPRETATION OF THE GENERAL APPEARANCE OF THE DESIGN. IT IS NOT INTENDED TO BE AN EXACT RENDITION. MAIN FLOOR 0" T.O.F. -6" B.O.F. -4' -0" W3W2W1 1' - 4"1' - 4"1' - 4" NOTE: -VERIFY ALL CHANGES IN WALL ELEVATION ON SITE. MAINTAIN 42" MINIMUM FROST PROTECTION AT ALL TIMES -NOT ALL WALL TYPES ARE USED 6" 3' - 0 " 8" 8" 8" 8" 4' - 0 " 8"8" 3' - 6 " VERIFY FOUNDATION HEIGHT WITH GRADE (O.H.D.) CF 16 1' - 4" 10 " W4 1' - 4" 6" 3' - 6 " 8" 8" W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W4 W4 W4 W4W4 W2 W2 W2 8" 26' - 8" 2' - 4" 8" 30' - 4"11' - 8" 42' - 0" 13 ' - 2 " 12 ' - 8 " 38 ' - 1 0 " 5' - 0 " 69 ' - 8 " 22' - 6" 1' - 6" 6' - 0" 12' - 0" 42' - 0" 3' - 10" 16' - 4" 2' - 4" 5' - 0 " 2 2 ' - 8 " 42 ' - 0 " 69 ' - 8 " 2' - 4 " 7 ' - 0 " 2 ' - 4 " 4 " 8" 40 ' - 8 " 26' - 8" 8" 22' - 8" 8" 17' - 4" 8" 8" 11 ' - 8 " 10 ' - 4 " STEP DOWN FOOTING AT O.H.D. NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL NOTE: STEP FOOTINGS DOWN AS GRADE REQUIRES. MAINTAIN MINIMUM FROST PROTECTION AT ALL TIMES. STOOP ABOVE STOOP ABOVE GARAGE ABOVE W4 45.00° NOTE: BACKFILL ALL EXCAVATIONS LOCATED BENEATH FLOOR SLAB WITH SAND OR OTHER COMPACTIBLE MATERIAL NOTE: STEP FOOTINGS DOWN AS GRADE REQUIRES. MAINTAIN MINIMUM FROST PROTECTION AT ALL TIMES. 4 A201 TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL TYPICAL CONCRETE SLAB CONST. * 4" REINFORCED CONC. SLAB O/ * 6 MIL. POLY VAPOR BARRIER O/ * 4"MIN. COMPACTED GRAN. FILL DOWEL STOOP SLAB TO FOUNDATION ELEVATION CHANGE DOWEL STOOP SLAB TO FOUNDATION -VERIFY ALL CHANGES IN WALL ELEVATION ON SITE -MAINTAIN 42" MINIMUM FROST PROTECTION AT ALL TIMES POST P20 FOOTING F30 F24 CF16 1'-8'' 2'-6'' 2'-0'' 1'-4'' DIA 2'-6'' 2'-0'' CONT 4'-0'' 1'-0'' 1'-0'' 10'' (2) #4 CONT. #4 AT 12" O.C. E.W. #4 AT 12" O.C. E.W. (2) #4 CONT. -NOT ALL TYPES ARE USED F36 3'-0'' 3'-0'' 1'-0'' #4 AT 12" O.C. E.W. 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A100 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y VE N E T O E S T A T E P L A N FO U N D A T I O N P L A N SCALE: 1/4" = 1'-0"2 FOOTING LEGEND SCALE: 1/4" = 1'-0"1 FOUNDATION PLAN FOUNDATION SCHEDULE Type Mark WALL FOOTING CommentsWidth Unconnected Height Hotizontal Reinforcements Vertical Reinforcements Footing Width Footing Length Footing Depth Footing Reinforcing W1 8" 3' - 6" #4 @ 24" O.C. #4 @ 20" O.C. 1'-4" CONT. 8" (2) #4 CONT. W2 8" 4' - 0" #4 @ TOP & BOT. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. W3 8" 3' - 0" #4 @ 48" O.C. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. W4 8" 3' - 6" #4 @ 48" O.C. #4 @ 48" O.C. 1'-4" CONT. 8" (2) #4 CONT. 42' - 0" 24' - 0" 6' - 0" 12' - 0" 38 ' - 1 0 " 25 ' - 1 0 " 64 ' - 8 " 4' - 6 " 6" 30' - 4"11' - 8" 42' - 0" 64 ' - 8 " 11'-1 1/8" CLG. 2/ 1 0 x 6 / 8 2/10 x 6/8 5/0 x 6/8 2/4 x 6/8 3/ 0 x 6 / 8 C . O . 5/0 x 6/8 C.O. 3/ 0 x 6 / 8 3/ 0 x 6 / 8 12' - 0" 12' - 0" 3' - 0" 3' - 0" 6' - 0" 6' - 0" 18 ' - 5 " 1 2 ' - 4 1 / 2 " 8 ' - 0 1 / 2 " 5 ' - 1 0 " 1 2 ' - 1 0 1 / 2 " 7 ' - 1 1 / 2 " 16' - 10" 3' - 8" 3' - 8" 3' - 8" 2' - 6" 5' - 6" 6' - 2" 6' - 0 " 14 ' - 0 " 10 ' - 1 1 1 / 2 " 11 ' - 0 1 / 2 " 22 ' - 8 " 2/10 x 6/8 2/10 x 6/8 D. 2/10 x 6/8 ROOF TRUSS ABV. @ 24" O.C. R/SR/SR/ S R/ S O.H.C. 6" 6' - 9 1/2" 2' - 4 1/2" 3' - 10 1/2" 2' - 4" 25' - 7 1/2" 6" 6" 3' - 5 " 4' - 0 " 5' - 9 " 12 ' - 4 1 / 2 " 5 1 / 2 " 7' - 7 1 / 2 " 3 1 / 2 " 3' - 1 " 4' - 0 1 / 2 " 5 1 / 2 " 22 ' - 2 " 6" 6" 10 ' - 0 " 3' - 2 " 12 ' - 4 1 / 2 " 4' - 6 " 11 ' - 0 " 5 1 / 2 " 3/ 0 x 6 / 8 C . O . 6" 8' - 6" 4' - 6 1/2" 2' - 2" 25' - 9 1/2" 6" LIVING ROOM DININGDEN MASTER BEDROOM MUD/LAUN. KITCHEN PA N T R Y TWO CAR GARAGE FOYER GUEST BEDROOM 2959 CSMT 2965 CSMT 72 8 2 S L D R 29 6 5 C S M T 2947 CSMT2929 TRSM2929 TRSM2947 CSMT 2' - 0" 11' - 0" 2' - 0" 6" 1' - 2 1/2"5' - 0 1/2" 7' - 9 1/2" 15' - 3 1/2" 6" 29 3 5 C S M T 29 2 9 T R S M 29 3 5 C S M T 29 3 5 C S M T W.C. 6" 11 ' - 1 0 " 2 ' - 6 1 / 2 " 5 ' - 1 0 " 2' - 5 " 3- 3- 3- 3- 2- D.T.D. 3' - 6" G.T.A. (2) 1 3/4 X 11 7/8 LVL HEADER 16/0 X 8/0 O.H.D. LINE OF O.H.D. IN OPEN POSITION NOTE: WALLS AND CEILING TO BE FINISHED W/ 5/8" TYPE "X" FIRE CODE GYPSUM BOARD ATTIC ACCESS PER CODE W. 6080 RO O F T R U S S A B V . @ 2 4 " O . C . ROOF TRUSS ABV. @ 24" O.C. BEAM ABOVE MECH. 3/0 x 6/8F.D. 4 A201 6" 23' - 0" 6" 6' - 0" 6" 3' - 11 1/2" 7' - 0 1/2" 6" M.BATH 3' - 6" 10' - 6 1/2" 2/10 x 6/82/ 1 0 x 6 / 8 2/ 4 x 6 / 8 NOTE: DIMENSIONS AND ROOM SIZES ARE SHOWN FOR DESIGN PURPOSES ONLY. DUE TO CONSTRUCTION MEANS, METHODS AND TOLERANCES, ROOM SIZES ARE SUBECT TO CHANGE WITHOUT NOTICE. 11' - 0" 16' - 0" REF SI N K RA N G E 11'-1 1/8" CLG. 2/ 1 0 x 6 / 8 COVERED PORCH 2' - 0" 60x32 TUB 4 SHELVES BATH 2' - 4 " 7 ' - 0 " 2 ' - 4 " 2' - 4" BEAR TRUSSES ON THIS WALL OPTIONAL 12" TRAY 12" TRAY CLG. OPTIONAL POCKET DOOR FURN WH 2 A201 Sim 3 A201 Sim HB HB NICHE 11 ' - 0 " A102 3 SH E L V E S 2' - 0 " 2' - 0" 2' - 0 " 135.00° SL O P E S L A B 6 " T O OV E R H E A D D O O R 0'-0" -0'-2" 4- 29 2 9 T R S M CL 3 CL 2 CL 1 O.H.C A102 5 15 ' - 2 1 / 2 " A2017 5 D.W. 6 A201 8 A201 9 A201 LAV. LAV. 2' - 0 " 2' - 0 " MW H O O D A201 11 A201 (2) 1 3/4x11 7/8 LVL HDR LAV. M. CLOSET COVERED PORCH 14 CO U N T E R T O P 9' - 7 " 3' - 11" 3' - 4" 3' - 10" 3' - 4" 5 3 / 8 " / 1 2 " 5 3 / 8 " / 1 2 " 6" / 12" 6" / 12" RIDGE RI D G E RI D G E RI D G EVALLEYVALLEYVALLEYVALLEYROOF NOTES: 2' - 0" EAVE OVERHANG*** 1' - 6" GABLE RAKES*** 10:12 SLOPE SIDE TO SIDE 7:12 SLOPE FRONT TO BACK ***UNLESS NOTED OTHERWISE PROVIDE RIDGE, HIP AND SOFFIT VENTING TO COMPLY W/ GOVERNING CODES SNOW AND ICE BARRIER ALONG ALL EAVES & RAKES 2' - 0" PAST OUTSIDE FACE OF FRAMING (TYPICAL @ ALL EXTERIOR EAVES) OUTSIDE FACE OF FRAMING BELOW 2' - 0 " 2' - 0" 2' - 0" 1' - 6 " 1' - 6 " 2' - 0 " 2' - 0" V ALLEY V A L L E Y V ALLE Y V A L L E Y RI D G E 1' - 9" 1' - 6 " 1' - 6 " 10" / 12"10" / 12" 10" / 12"10" / 12" 10" / 12"10" / 12" D.W. O.H.C. REF RA N G E PA N T R Y 2/10 x 6/8 MUD/LAUN. 2/ 1 0 x 6 / 8 3/0 x 6/8 3/ 0 x 6 / 8 3/ 0 x 6 / 8 C . O . KITCHENLO C K E R O.H.C. W.D. A2017 5 6 O.H.C. A201 MW HO O D A201 11 1 3/8" 3' - 0" 1 3/8" 3' - 3" 3' - 3" 1 3/8" 3' - 0" 1 3/8" 12' - 11 1/2" 1' - 0 " 3' - 3" 3' - 3" 1 1/2" 3' - 0" 1 1/2" 9' - 9" 1' - 3 " 2 ' - 6 1 / 2 " 1 ' - 3 " 1 " 5' - 1 1 / 2 " 9' - 7 " 1/ 2 " 3' - 0 " 2' - 0 " 3' - 0 " 1' - 6 " 1/ 2 " A201 12 O.H.C.O.H.C.O.H.C. O. H . C . O. H . C . O.H.C. MECH. 14 CO U N T E R T O P 3/4" 2' - 0" 1' - 3 1/4" 3' - 4" D.W. O.H.C. REF RA N G E D.W. LO C K E R 2/ 6 x 6 / 8 2/10 x 6/8 3/ 0 x 6 / 8 3/ 0 x 6 / 8 C . O . 3/0 x 6/8 MECH. O. H . C . PANTRY MUD/LAUN. KITCHEN O.H.C A2017 5 6A20110 A201 11 MW H O O D A201 O. H . C . O.H.C O.H.C. O.H.C. 2' - 6" 2' - 6" 5' - 0" 1' - 0 " 1' - 3 " 2 ' - 6 " 1 ' - 3 " 2 ' - 3 " 2 ' - 3 " 1/ 2 " 3' - 0 " 2' - 0 " 3' - 0 " 1' - 6 " 1/ 2 " 3/4" 2' - 0"1' - 3 1/4" 9' - 7 " 3' - 4" 3' - 3" 3' - 3" 1 1/2" 3' - 0" 1 1/2" 9' - 9" 14 CO U N T E R T O P OPT. FP 3' - 1 1/2" 5' - 0" 3' - 8" 2' - 0 " 1 3 ' - 2 1 / 2 " 2965 CSMT 29 2 9 T R S M 4- 3- LIVING ROOM 1" 3' - 0" 1' - 3" 3' - 0" 1" 7' - 5" 1' - 1 0 1 / 2 " 1' - 1 0 1 / 2 " 1' - 9" 1' - 9" 3' - 6" 1' - 1 0 1 / 2 " 1' - 1 0 1 / 2 " 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A102 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y VE N E T O E S T A T E P L A N MA I N F L O O R P L A N SCALE: 1/4" = 1'-0"1 MAIN FLOOR SCALE: 1/4" = 1'-0"2 ROOF PLAN SCALE: 1/4" = 1'-0"3 KITCHEN/MUD - OPTION B SCALE: 1/4" = 1'-0"4 KITCHEN/MUD - OPTION C SCALE: 1/4" = 1'-0"5 FIREPLACE OPTION SCALE: 1/4" = 1'-0"6 VENETO MASTER BATH SCALE: 1/4" = 1'-0"7 VENETO BATH MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MAIN WIN. H.H. 6' -10" F1 R1 S4 C1 M1 S1 L1 CONCRETE SLOPE TO GRADE B3 T1 3535 CSMT 3535 CSMT T4 T5 F1 M2 T5 T4 T7 T7 M1 M2 B3 B3 S4 T1 S4 T2 S1 S4 T7 16' - 10 5/8" MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MAIN WIN. H.H. 6' -10" F1 S1 C1 M1 T5 T2 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE F1M2 R1 S1 F1 L1 T2 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE M1 F1 F1C1 M2 R1 F1 C1 M1 S1 T1 T2 HOLD ALL SIDING AND TRIM MIN. 6" ABOVE GRADE F1M2 T2T5 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A200 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y VE N E T O E S T A T E P L A N EL E V A T I O N S SCALE: 1/4" = 1'-0"1 FRONT SCALE: 1/4" = 1'-0"2 BACK SCALE: 1/8" = 1'-0"3 LEFT SCALE: 1/8" = 1'-0"4 RIGHT Keynote Legend Key Value Keynote Text B3 DECORATIVE BRACKET - FYPON BKT25X27 C1 COLUMN WRAP - OR - TRIM OUT COLUMN F1 6" ALUMINUM FASCIA OR 6" ALUMINUM RAKE L1 EXTERIOR WALL LIGHT M1 MASONRY- CULTURED STONE M2 MASONRY- STONE CAP R1 LAMINATED ASPHALT ROOF SHINGLES S1 (LAP SIDING) HARDIE-PLANK SIDING-7" MAX EXPOSURE S4 (SHAKE SIDING) T1 PAINTED HARDIE CORNER TRIM T2 4" PAINTED TRIM T4 6" OVER 8" PAINTED TRIM T5 7" OVER 12" PAINTED TRIM T7 4" TRIM AT WINDOWS ON FRONT ELEVATION ONLY MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" T.O.F. -6" SIMPSON POST STANDOFF 6X6 TRTD TIMBER POST BLOCKING AS REQ'D PAINTED COLUMN TRIM 3" 6"6" THIN VENEER ADHERED MASONRY FOUNDATION WALL- SEE FOUNDATION PLAN 7" 2" STONE CAP SEE ROOF PLAN 36" PLASTIC ATTIC CHUTE SNOW AND ICE BARRIER EXTEND 24" PAST I.S. FACE OF EXTERIOR WALLS LAMINATED ASPHALT ROOF SHINGLES ON 15# ROOF FELT ON 1/2" O.S.B. SHEATHING MTL. DRIP 2X6 SUB-FASCIA VENTED ALUMINUM SOFFIT & FASCIA ON 2X4 LOOKOUTS @ 24" O.C. 7" OVER 12" PAINTED TRIM SEE ELEVATIONS FOR SIDING MATERIAL WEATHER RESISTANT BARRIER OVER 1/2" O.S.B. SHEATHING ON 2X6 WALL STUDS @16" O.C. R21 INSULATION 1/2" GYP. BD. ON 6MIL POLY VAPOR BARRIER FLASHING (ALL HORIZ. JOINTS) 2X6 SILL PLATE "TRTD" ON CLOSED CELL FOAM SILL SEALER R49 BLOWN INSULATION 12 SE E R O O F PL A N MAIN FLOOR 12 " E N E R G Y H E E L M I N . T.O.F. 0'-0" 0'-4" FOUNDATION WALL-REFER TO PLAN TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL MAIN FLOOR PLT. HT. 9'-1 1/8" HOLD ALL TRIM AND SIDING MIN. 6" ABOVE GRADE 9' - 1 1 / 8 " CONTINUOUS BEAD OF SEALANT 4"4" 4' - 0 " LINE OF GRADE (VARIES) 2" 4" 2' - 0" HOLD ALL TRIM AND SIDING MIN. 6" MIN. ABOVE GRADE MAIN FLOOR 0'-0" TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL CONTINUOUS BEAD OF SEALANT 4"4" 2" 4" 2' - 0"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE GARAGE SLAB (SLOPE TO OVERHEAD DOOR) MAIN FLOOR 0'-0" TYPICAL SLAB CONSTRUCTION -4" REINFORCED CONCRETE SLAB -6 MIL. POLY VAPOR BARRIER -4" MIN. COMPACTED GRAN. FILL CONTINUOUS BEAD OF SEALANT 4"4" 2" 2' - 0"2" RIGID INSULATION VERIFY FLOORING FINISH WITH CONTRACTOR ADA-COMPLIANT THRESHOLD SET IN TWO CONTINUOUS BEADS OF SEALANT 4" CONCRETE SLAB (SLOPE AWAY FROM HOUSE) MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8"1 1/2" 3' - 0" 1 1/2" 3' - 3" 3' - 3" 9' - 9" 2' - 1 0 1 / 2 " 1 1 / 2 " 1' - 6 " 3 ' - 0 " 6' - 0 " 1 ' - 6 " 7' - 6 " REF 1 1/2" 3' - 0" 1 1/2" 3' - 3" 3' - 3" 9' - 9" 7' - 6 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 1/2" 3' - 0" 2' - 0" 3' - 0" 1' - 6" 1/2" 9' - 7" 1 1 / 2 " 2' - 1 0 1 / 2 " 3' - 0 " DW WINDOWS BEYOND MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" PANTRY MW HOOD RANGE 1' - 3" 2' - 6 1/2" 1' - 3" 1" 5' - 1 1/2" 1' - 3" 2' - 6" 1' - 3" 1 1/4" 5' - 1 1/4" 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 7' - 6 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 1"3' - 0"1' - 3"3' - 0"1" 7' - 5" 1 1 / 2 " 2' - 1 0 1 / 2 " 3' - 0 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 2' - 1 0 1 / 2 " 1 1 / 2 " 4" 3' - 6" 3' - 0 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MW HOOD RANGE 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 7' - 6 " 1' - 3" 2' - 6" 1' - 3" 2' - 3" 2' - 3" 9' - 6" 1' - 3" 2' - 6 1/2" 1' - 3"2' - 3" 2' - 3" 9' - 6 1/2" 3' - 0 " 1' - 6 " 1 1 / 2 " 2' - 1 0 1 / 2 " 7' - 6 " MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" W.D. 3' - 0 " 4' - 6 " 7' - 6 " 2' - 6" 2' - 6" 5' - 0" MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" 7' - 6 " 3' - 0 " 4' - 6 " 1 3/8" 3' - 0" 1 3/8" 3' - 3" 3' - 3" 1 3/8" 3' - 0" 1 3/8" 12' - 11 1/2" W.D. MAIN FLOOR 0" MAIN PLT. HT. 9' -1 1/8" MAIN WIN. H.H. 6' -10" 3' - 0 " 2' - 1 0 1 / 2 " 1 1 / 2 " 7' - 6 1/2" COUNTERTOP 16 0 5 N . A N K E N Y B L V D # 1 3 0 AN K E N Y , I O W A 5 0 0 2 3 PH O N E : ( 5 1 5 ) 9 6 5 - 5 3 3 6 FA X : ( 5 1 5 ) 9 6 5 - 5 3 3 5 in f o @ i m p r i n t a r c h i t e c t s . c o m PR O J E C T : DATE: DR A W N B Y : CH K ' D BY : DA T E : I S S U E D F O R : 11 - 2 3 - 2 0 F O R C O N S T R U C T I O N 11 - 3 0 - 2 0 R E V I S E D F L O O R F I N I S H S C H E D U L E 12 - 0 9 - 2 0 R E V I S E D P L A N C H A N G E S 02 - 0 9 - 2 1 C A S E W O R K E L E V A T I O N S 03 - 1 8 - 2 1 O W N E R R E Q U E S T E D C H A N G E S A201 19-137.2 3-18-2021 MS P L A N LR K C VI N T A G E E S T A T E S - N O R T H L I B E R T Y VE N E T O E S T A T E P L A N DE T A I L S SCALE: 1/2" = 1'-0"4 TYPICAL VENETO COLUMN DOOR SCHEDULE Level Mark Width Height Material Finish Comments MAIN FLOOR FOYER - OPENING 0" 0" MAIN FLOOR BATH 2' - 10" 6' - 8" MAIN FLOOR DINING 6' - 0" 6' - 10" MAIN FLOOR BEDROOM CL. 5' - 0" 6' - 8" MAIN FLOOR BEDROOM 2' - 10" 6' - 8" MAIN FLOOR LIVING ROOM - OPENING 0" 0" MAIN FLOOR LINEN 2' - 4" 6' - 8" T.O.F. GARAGE - OHD 16' - 0" 8' - 0" MAIN FLOOR FOYER 5' - 2" 7' - 0" MAIN FLOOR MUD 3' - 0" 6' - 8" MAIN FLOOR MASTER BEDROOM 2' - 10" 6' - 8" MAIN FLOOR MASTER BATH 2' - 10" 6' - 8" MAIN FLOOR DEN 5' - 0" 6' - 8" MAIN FLOOR KITCHEN - OPENING 0" 0" MAIN FLOOR PANTRY 2' - 10" 6' - 8" MAIN FLOOR MUD CL. 2' - 4" 6' - 8" MAIN FLOOR MECH 3' - 0" 6' - 8" MAIN FLOOR M. WIC 2 2' - 10" 6' - 8" MAIN FLOOR TOILET 2' - 10" 6' - 8" MAIN FLOOR M. WIC 3 2' - 10" 6' - 8" MAIN FLOOR 655 5' - 0" 6' - 0" MAIN FLOOR M. WIC 4 2' - 10" 6' - 8" MAIN FLOOR M. WIC 5 2' - 6" 6' - 8" WINDOW SCHEDULE Mark Width Height Material Finish Comments BATH 2' - 5" 2' - 11 1/16" BEDROOM 1 2' - 5" 4' - 11 1/16" BEDROOM 2 2' - 5" 4' - 11 1/16" BEDROOM 3 2' - 5" 4' - 11 1/16" DEN 1 2' - 5" 2' - 5 1/16" DEN 2 2' - 5" 2' - 5 1/16" DEN 3 2' - 5" 2' - 5 1/16" GABLE 2' - 11" 2' - 11 1/16" GARAGE GABLE 2' - 11" 2' - 11 1/16" LAUNDRY 1 2' - 5" 2' - 11 1/16" LAUNDRY 2 2' - 5" 2' - 11 1/16" LAUNDRY 3 2' - 5" 2' - 5 1/16" LAUNDRY 4 2' - 5" 2' - 5 1/16" LAUNDRY 5 2' - 5" 2' - 5 1/16" LIVING ROOM 1 2' - 5" 5' - 5 1/16" LIVING ROOM 2 2' - 5" 5' - 5 1/16" LIVING ROOM 3 2' - 5" 5' - 5 1/16" LIVING ROOM 4 2' - 5" 2' - 5 1/16" M. BATH 2' - 5" 2' - 11 1/16" M. BEDROOM 1 2' - 5" 3' - 11 1/16" M. BEDROOM 2 2' - 5" 2' - 5 1/16" M. BEDROOM 3 2' - 5" 2' - 5 1/16" M. BEDROOM 4 2' - 5" 3' - 11 1/16" M. BEDROOM 5 2' - 5" 5' - 5 1/16" M. BEDROOM 6 2' - 5" 5' - 5 1/16" M. BEDROOM 7 2' - 5" 5' - 5 1/16" NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL SCHEDULES PRIOR TO BIDDING AND CONSTRUCTION. VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION. NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL SCHEDULES PRIOR TO BIDDING AND CONSTRUCTION. VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION. ROOM FINISH SCHEDULE-MAIN FLOOR Level ROOM NO ROOM NAME AREA FLOOR BASE WALLS CEILING CEILING NOTESN E S W HEIGHT MAIN FLOOR 030 LIVING ROOM 279 SF LVP MAIN FLOOR 031 DINING 207 SF LVP MAIN FLOOR 032 DEN 133 SF CARPET MAIN FLOOR 033 MASTER BEDROOM 192 SF CARPET MAIN FLOOR 036 MUD/LAUN. 67 SF LVP MAIN FLOOR 037 KITCHEN 117 SF LVP MAIN FLOOR 038 PANTRY 7 SF LVP MAIN FLOOR 040 TWO CAR GARAGE 510 SF CONCRETE MAIN FLOOR 041 FOYER 70 SF LVP MAIN FLOOR 042 GUEST BEDROOM 137 SF CARPET MAIN FLOOR 045 MECH. 57 SF CONCRETE MAIN FLOOR 046 M.BATH 157 SF LVT MAIN FLOOR 047 COVERED PORCH Not Enclosed MAIN FLOOR 048 COVERED PORCH Not Enclosed MAIN FLOOR 049 BATH 52 SF LVT MAIN FLOOR 050 PANTRY 13 SF LVP MAIN FLOOR 051 CL 3 15 SF CARPET MAIN FLOOR 052 CL 2 8 SF LVP MAIN FLOOR 053 CL 1 6 SF LVP NOTE: THIS SCHEDULE IS PROVIDED FOR CONVENIENCE PURPOSES ONLY. GENERAL CONTRACTOR TO VERIFY ALL SCHEDULES PRIOR TO BIDDING AND CONSTRUCTION. VERIFY FINISHES NOT SPECIFIED WITH GENERAL CONTRACTOR PRIOR TO BIDDING AND CONSTRUCTION. SCALE: 1/2" = 1'-0"1 TYPICAL SLAB ON GRADE WALL SECTION SCALE: 1" = 1'-0"2 TYP. ZERO ENTRY DETAIL - GARAGE SCALE: 1" = 1'-0"3 TYP. ZERO ENTRY DETAIL - STOOP SCALE: 1/4" = 1'-0"5 BASE KITCHEN/OPTION B + C ELEV. SCALE: 1/4" = 1'-0"6 KITCHEN ISLAND ELEV. SCALE: 1/4" = 1'-0"7 BASE KITCHEN/OPTION B ELEV. SCALE: 1/4" = 1'-0"8 MASTER BATH ELEVATION SCALE: 1/4" = 1'-0"9 BATH ELEVATION SCALE: 1/4" = 1'-0"10 KITCHEN ELEVATION - OPTION C SCALE: 1/4" = 1'-0"11 LAUNDRY ELEVATION 1 SCALE: 1/4" = 1'-0"12 LAUNDRY ELEVATION - OPTION B SCALE: 1" = 1'-0"13 TERMITE GUARD SCALE: 1/4" = 1'-0"14 LAUNDRY ELEVATION 1 ABV.ABOVE ACT ACOUSTIC CEILING TILE ALUM. ALUMINUM APP APPENDIX AWN.AWNING BRG.BEARING BM.BEAM CAB.CABINET C.J.CONTROL JOINT CLG.CEILING C.M.U. CONCRETE MASONRY UNIT COL.COLUMN CONC. CONCRETE CONT. CONTINUOUS CPT.CARPET CSMT CASEMENT C.T.CERAMIC TILE DBL DOUBLE D.H.DOUBLE HUNG DIA.DIAMETER DIM.DIMENSION DR.DOOR D.S.DOWNSPOUT D.W.DISHWASHER EA.EACH EIFS EXTERIOR INSULATION AND FINISH SYSTEM EL.ELEVATION EQ.EQUAL EXT EXISTING EXST.EXISTING F.B.O.FURNISHED BY OWNER F.D.FLOOR DRAIN F.E.FIRE EXTINGUISHER FLUOR FLUORESCENT F.R.P.W. FIRE RETARDANT PLYWOOD FTG.FOOTING GALV. GALVANIZED G.F.I.GROUND FAULT CIRCUIT INTERRUPTER GL.GLASS GYP. BD. GYPSUM BOARD H.M.HOLLOW METAL H.V.A.C. HEATING VENTILATING & AIR CONDITIONING HORIZ. HORIZONTAL INSUL. INSULATED/INSULATION LAV.LAVATORY MFR MANUFACTURER M.C.MEDICINE CABINET M.D.O. MEDIUM DENSITY OVERLAY MTL.METAL MIN.MINIMUM N.T.S.NOT TO SCALE O.C.ON CENTER O.H.OVERHEAD O.H.C. OVERHEAD CABINET PED PEDESTAL PNT PAINT PL.PLATE P. LAM PLASTIC LAMINATE P.S.F.POUNDS PER SQUARE FOOT R.D.ROOF DRAIN REF.REFRIGERATOR R.S.ROUGH SAWN S.D.SMOKE DETECTOR SH.SHELF S.F.SQUARE FOOT SL.GL.DR. SLIDING GLASS DOOR SPR.SPRINKLER TEMP. TEMPERED THLD THRESHOLD T.O.F.TOP OF FRAMING TRT.TREATED U.N.O. UNLESS NOTED OTHERWISE VB VINYL BASE VCT VINYL COMPOSITION TILE VERT.VERTICAL W WIDE W/WITH W.C.WATER CLOSET WD.WOOD WDW.WINDOW W.H.WATER HEATER W.P.WEATHERPROOF W.R.WATER RESISTANT W.S.WIRE SHELF ABBREVIATIONS SECTION DESTINATION SHEET NUMBER DETAIL NUMBER SHEET NUMBER 1STOREFRONT & WINDOW TYPE WALL TYPE ELEVATION HEIGHT ELEVATION TYPE SYMBOLS 1DOOR NUMBER MATERIALS RIGID INSULATION CONCRETE EARTH BRICK CONCRETE BLOCK BATT INSULATION GYPSUM BOARD GRAVEL STEEL OR STEEL STUD WALL PLYWOOD WOOD OR WOOD STUD WALL SOUND INSULATION IN WALLP1A ALL WORK SHALL COMPLY WITH APPLICABLE CODES, RULES, ORDINANCES, AND REGULATIONS IN FORCE AT TIME OF CONSTRUCTION AND REQUIRED BY THE LOCAL BUILDING AUTHORITIES. THE GOVERNING CODE, RULES, ORDINANCES, AND REGULATIONS ARE COLLECTIVELY REFERRED TO AS THE "CODE". THE CONTRACTOR SHALL REPORT ANY INCONSISTENCIES, CONFLICTS OR OMISSIONS HE MAY DISCOVER TO THE ARCHITECT FOR INTERPRETATION PRIOR TO PERFORMING THE WORK. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, EXISTING AND NEW CONDITIONS ON THE JOB BEFORE PROCEEDING WITH THE WORK. DISCREPANCIES, IF ANY, ARE TO BE REFERRED TO THE ARCHITECT PRIOR TO START OF WORK. DOORS NOT LOCATED BY DIMENSION ON PLANS OR DETAILS SHALL BE INSTALLED SUCH THAT THE DOOR, WHEN IN THE FULL OPEN POSITION AGAINST WALL STOP, IS PARALLEL TO ADJACENT WALL. COORDINATE WITH DOOR HARDWARE. CONTRACTORS SHALL CONSULT PLANS OF ALL TRADES FOR ADDITIONAL INFORMATION INCLUDING BUT NOT LIMITED TO OPENINGS AND ROUGH-INS, ROUGH-OUTS THROUGH SLABS, WALLS, CEILINGS, AND ROOFS FOR DUCTS, PIPES, CONDUITS, CABINETS AND EQUIPMENT, AND SHALL VERIFY SIZE AND LOCATION BEFORE PROCEEDING WITH WORK.NO DEVIATION FROM THE STRUCTURAL, MEP AND ANY OTHER DISCIPLINES' DESIGN WITHOUT WRITTEN APPROVAL OF THE APPLICABLE AUTHORITY TO DEVIATE FROM THE PLANS OR SPECIFICATIONS. PROVIDE FIRE RESISTIVE CLOSURE, MEETING THE REQUIREMENTS OF THE GOVERNING FIRE AUTHORITIES, AT ALL GAPS AROUND THE PENETRATING DUCT, PIPES, CONDUITS, OR LIKE ITEMS, AT ALL FIRE RATED BUILDING PARTITIONS AND CEILINGS. ANNULAR SPACE ASSOCIATED WITH NONCOMBUSTIBLE PENETRATING ITEMS SHALL BE FILLED WITH APPROVED NONCOMBUSTIBLE MATERIAL OR AN APPROVED THROUGH-PENETRATION FIRESTOP SYSTEM. THE CONTRACTOR SHALL VERIFY ALL ROUGH-IN DIMENSIONS AND EQUIPMENT, FURNISHED AND INSTALLED BY HIMSELF/HERSELF OR OTHERS, PRIOR TO PROCEEDING WITH WORK. ROOM FINISH SCHEDULE SHALL NOT BE TAKEN AS A COMPLETE SPECIFICATION FOR ALL INTERIOR ROOM MATERIALS. HOWEVER, IT SHALL BE BINDING TO THE EXTENT OF THE MATERIAL IT DOES SPECIFY. THE CONTRACTOR SHALL CHECK THE SCHEDULE WITH SPECIFICATIONS AND DRAWINGS FOR OTHER MATERIALS NOT COVERED BY THE SCHEDULE. REFER TO SPECIFICATIONS FOR ACCESS DOORS AND CONSULT WITH MECHANICAL CONTRACTOR FOR EXACT LOCATIONS OF ACCESS REQUIRED BY THEIR WORK. ACCESS MUST BE PROVIDED FOR ALL CONCEALED VALVES, DAMPER CONTROLS, FIRE DAMPER LINKAGE, ELECTRICAL JUNCTION BOXES, ETC. OBTAIN ARCHITECT'S APPROVAL IN LOCATING ALL ACCESS DOORS PRIOR TO INSTALLATION. CONTRACTOR SHALL COORDINATE WITH ALL OWNER FURNISHED ITEMS AND PROVIDE ALL REQUIRED MECHANICAL AND ELECTRICAL CONNECTIONS, INCLUDING STUB OUTS FOR NEW OR FUTURE WORK INDICATED. INTERIOR NONBEARING STUD PARTITIONS SHALL BE CONSTRUCTED PER WALL TYPES SCHEDULE FOR ALL WALLS EXCEPT AS SPECIFICALLY NOTED OR DIMENSIONED OTHERWISE. PROVIDE CONSTRUCTION AND CONTROL JOINTS IN CONCRETE SLABS ON GRADE AS SHOWN OR DETAILED ON STRUCTURAL DRAWINGS, IF NOT SHOWN,PROVIDE JOINTING PLAN ELECTRICAL OUTLETS AND COMMUNICATION RECEPTACLES SHOWN ON ARCHITECTURAL DRAWINGS DO NOT INCLUDE THE ENTIRE SCOPE OF WORK AND ARE SHOWN WHERE THERE MAY BE COORDINATION ISSUES WITH OTHER WORK. FOR FURTHER CLARIFICATION, CONSULT ELECTRICAL DRAWINGS. PROVIDE BLOCKING IN PARTITIONS AS REQUIRED FOR ALL ITEMS ATTACHED TO WALLS, INCLUDING OWNER FURNISHED ITEMS. THE FAIR HOUSING ACT REQUIRES ADDITIONAL BLOCKING IN WALLS BEYOND THE STANDARD LOCATIONS OF GRAB BARS IN COMMERCIAL CONSTRUCTION. PROVIDE BLOCKING TO ACCOMMODATE THE FULL RANGE OF MOUNTING POSSIBILITIES. ALL CONCEALED WOOD BLOCKING IN INTERIOR WALLS IS REQUIRED TO BE FIRE TREATED. ALL GYPSUM BOARD TO BE 5/8" TYPE "X". USE WATER RESISTANT GYPSUM BOARD AT WET AREAS AND CEMENTITIOUS BACKER BOARD AT SHOWERS. ALL PENETRATIONS AND JOINTS OF DRYWALL AT ACOUSTIC WALLS ARE TO BE ACOUSTICALLY SEALED. DETAILS ARE USUALLY KEYED ONLY ONCE (ON PLANS OR ELEVATIONS WHEN THEY FIRST OCCUR) AND ARE TYPICAL FOR SIMILAR CONDITIONS THROUGHOUT UNLESS NOTED OTHERWISE. DRYWALL SUBCONTRACTOR IS REQUIRED TO REPAIR AND REFINISH ALL 'TO REMAIN' EXISTING CEILINGS AND WALLS WHICH MAY BE PENETRATED OR CUT AWAY FOR NEW MECHANICAL, ELECTRICAL, PLUMBING, OR FIRE PROTECTION WORK. ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. NO DEADBOLTS, NO SLIDING BOLTS, ETC. EXISTING WALL CONSTRUCTION TO BE FIELD VERIFIED IN AFFECTED AREAS. ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THOSE DEFINED IN THESE DOCUMENTS ARE TO BE BROUGHT TO THE ARCHITECTS ATTENTION. CONTRACTOR TO COORDINATE TIMING AND LOCATION OF TEMPORARY SEPARATION WALLS WITH OWNER. LOCATION AND SIZING OF BLOCKING FOR ALL FIXTURES SHALL BE COORDINATED WITH INTERIOR DESIGNER. READILY VISIBLE AND/OR TACTILE SIGNAGE SHALL BE PROVIDED AS REQUIRED FOR ADDRESS/SUITE; FIRE EXTINGUISHER CABINETS; STAIRS, EXITS AND EXIT ACCESS (INCLUDING OUTDOOR AREAS); AND BATHROOMS. AN EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE AISLES, CORRIDORS, AND EXIT ACCESS STAIRWAYS AND RAMPS WHERE 2 OR MORE MEANS OF EGRESS ARE REQUIRED. CONTRACTOR SHALL PROVIDE AND COORDINATE ALL REQUIRED FIRE PROTECTION DRAWINGS AND EQUIPMENT WITH THE FIRE MARSHALL. GENERAL PROJECT NOTES: 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com PR O J E C T : DATE:DRAWN BY: CHK'D BY: REVISED: NOT FOR CONSTRUCTIONC: \ U s e r s \ m t a y l o r \ D o c u m e n t s \ 1 9 - 1 3 7 . 4 D u b u q u e C o o p e r a t i v e L i v i n g - D e t a c h e d _ I A - m t a y l o r . r v t 11 / 3 0 / 2 0 2 1 1 1 : 0 2 : 3 4 A M G000 19-137 ----WA U K E E CO O P C L U B H O U S E CO V E R S H E E T 11/30/2021 MT KC ARCHITECT: 1605 N. ANKENY BLVD, STE 130 ANKENY, IA 50023 CONTACT: KARL CHAMBERS 515-965-5336 OWNER: IMPRINT ARCHITECTS PROJECT: WAUKEE, IA 50263 WAUKEE CLUBHOUSE MECHANICAL ENGINEER: 2521 WASHINGTON STREET, PELLA, IA 50219 CONTACT: RAY BISBEE 641-628-0073 EWING LAND DEVELOPMENT ELECTRICAL ENGINEER:STRUCTURAL ENGINEER: -- TBD -- TBD 4717 GRAND AVE, DES MOINES, IA 50312 CONTACT: BRIAN THOMAS 515-277-0275 RAKER RHODES KARL E CHAMBERS IOW A ** 5486 A R C HI CTL I CENSED P R O F E SSI AL ON TE I hereby certify that the portion of this technical submission described below was prepared by me or under my direct supervision and responsible charge. I am a duly licensed architect under the laws of the state of Iowa. KARL E. CHAMBERS DATE: Pages or sheets covered by this seal: My license expiration date is : June 30, 2022 ARCHITECTURE A000 ARCHITECTURAL GENERAL INFORMATION A010 CODE PLANS REVIEW A100 MAIN FLOOR PLAN A101 MAIN FLOOR PLAN A102 MAIN FLOOR PLAN A103 MAIN FLOOR PLAN A120 REFLECTED CEILING PLAN A130 ROOF PLAN A200 EXTERIOR ELEVATIONS A300 BUILDING SECTIONS A301 BUILDING SECTIONS A310 WALL SECTIONS A311 WALL SECTIONS A312 WALL SECTIONS A400 ENLARGED PLANS, ELEVATION, & SECTIONS A401 ENLARGED PLANS, ELEVATION, & SECTIONS A402 ENLARGED PLANS, ELEVATION, & SECTIONS A500 DETAILS A501 DETAILS A600 DOOR & FRAME SCHEDULE A900 FINISH FLOOR PLAN SHEET LIST NO.SHEET NAME GENERAL G000 COVER SHEET G000,A000,A010,A100,A101,A102,A103,A120,A130,A200,A300,A301,A310,A311,A312, A400,A401,A402,A500,A501,A600,A900 STRUCTURAL S001 S101 S201 S301 S401 STRUCTURAL NOTES FOUNDATION PLAN FOUNDATION DETAILS FRAMING PLAN FRAMING DETAILS 42"18" 60" 56 " CLEAR FLOOR AREA TO P O F B A R 33 " - 3 6 " MIN. 24" MIN. 12" 36" MIN. 12" MAX.42" MIN. 54" MIN. 48 " M A X . 15 " M I N . CL 7"-9" MI N . 18 " 40 1 / 4 " 39"-41" MIN. 24" Y NOTE:Y = 48 IN. MIN. W/O CLOSER Y = 54 IN. MIN. W/ CLOSER MIN. 24" Y NOTE:Y = 42 IN. MIN. W/O CLOSER Y = 48 IN. MIN. W/ CLOSER PULL SIDE PUSH SIDE MIN. X Y NOTE:X = 36 IN. MIN. WHEN Y ≥60 IN. X = 42 IN. MIN. WHEN Y ≥54 IN., BUT < 60 IN. Y NOTE:Y = 42 IN. MIN. Y = 48 IN. MIN. W/ CLOSER & LATCH PULL SIDE PUSH SIDE MIN. 22" MIN. 18" 60 " M I N . MIN. 12" 48 " M I N . NOTE:12" SIDE CLEARANCE REQUIRED WHEN DOOR EQUIPED WITH BOTH CLOSER & LATCH PULL SIDE PUSH SIDE MIN. 18" MIN. 18" FACE OF SIGNAGE AREA OF REFUGE AREA OF REFUGE 48" MIN. 60" MAX. **TACTILE LETTERS 5/8" MINIMUM IN HEIGHT CLEAR 48" MIN. CLEAR 30" MIN. TO FINISHED SURFACE 15" MIN. TO RIM 34" MAX. 40" MAX. 34" MAX. 17" MIN. 6" MAX. 8" MIN. CLEAR AREA 9" MIN. 17"-19" CLEAR 48" MIN. CLEAR 30" MIN.6" MAX.8" MIN. 27" MIN. TO BUBBLER 36" MAX 17"-19" X > 27" 4" MAX. X ≥ 80" 27" MAX.CLEARANCE X < 80" 15" MIN. 48" MAX. CLEAR FLOOR AREA 48" CLEAR FLOOR AREA 30" 20" MAX. 48" MAX. >20"-25" MAX. 44" MAX. 27" MIN. 28"-34" 27" MAX. 28"-34" MAX. 10" 15" MIN. 48" MAX. MAX. 10" 34" MAX. 48" MAX. 10"-24" MAX. 34" MAX. 46" MAX. CLEAR FLOOR AREA 30" MAX. 10" CLEAR FLOOR AREA 48" SE A T WA L L CO N T R O L W A L L MAX. 18" GRAB BAR 4" MAX. SHOWER HEAD 36" INSIDE FACE OF FINISH36 " x 4 8 " C L E A R 36" INSIDE FACE OF FINISH 30" TYPICAL 60" CO N T R O L W A L L BACK WALL HE A D EN D WA L L MIN. 12" MIN. 24" MAX. 12" MIN. 24" MAX. 24" GRAB BARGRAB BAR 30" LENGTH OF TUB + SEAT + 12" SE A T 12"CO N T R O L W A L L BACK WALL HE A D EN D WA L L 12"15" 24" GRAB BAR 42" GRAB BAR 10"46" 8" 30" 28"4" 8" 30" 24" GRAB BAR 30" 8" TUB DEPTH OF 6"6" 6" 38" 30" 8" TUB DEPTH OF 30" 8" SHOWER DEPTH OF 8" 30" SHOWER LENGTH OF 8" 6" 24" SHOWER DEPTH OF 33"-36" 8"-10" MAX. 12" MAX. 15" THIS DATA IS PROVIDED AS AN ADDITIONAL RESOURCE TO THE TEAM OF OWNER, CLIENT, ARCHITECT, ENGINEER, AND SPECIFICALLY, CONTRACTOR. THIS IS A TOOL TO APPRISE ALL PARTIES OF GENERAL ACCESSIBLE CONDITIONS AS PUBLISHED PER THE "ICC ANSI A117.1-2009 ACCESSIBILE AND USABLE BUILDINGS AND FACILITIES". THE DIAGRAMS ARE VERBATIM DUPLICATIONS OF THE STANDARDS AND ARE NOT INDICATIVE OF ALL CONDITIONS AND CERTAINLY DO NOT FULLY REPRESENT THE ENTIRETY OF THE WRITTEN GUIDELINES AS CONTAINED IN THE STANDARDS. THIS DATA IS IN SUPPORT OF GENERAL ARCHITECTURAL AND ENGINEERING DOCUMENTATION, WHICH IS INTENDED TO BE CONSISTENT WITH ACCESSIBLE CONDITIONS. THIS DATA IS PROVIDED TO ACT AS AN ADDED SAFEGUARD TO FULLY FAMILIARIZE THE TEAM WITH EXPECTATIONS ASSOCIATED WITH THE 2009 ANSI STANDARDS AND TO ASSIST THE TEAM IN ACHIEVING FULLY ACCESSIBLE CONDITIONS AS REQUIRED BY CIVIL LAW. WE ENCOURAGE THE DETAILED REVIEW BY OWNER AND CONTRACTOR. 2009 ANSI A117.1 STANDARDS GENERAL NOTES: MAX. 1/2"MAX. 1/4" 1/4" 1/4" MAX.MAX. 1/2" 2 1 MAX. 1/2" 2 1 1/4"-1/2" 36" MIN. X > 24" X > 15" 60" MIN. 9" MAX. 6" 30" MIN. 17"-25" ELEVATION PLAN 27" MIN. 8" MIN. 9" MIN. 11" MIN. 25" MAX. 30" MIN. ELEVATION PLAN 42" MIN. X < 48" 42" MIN.36" MIN. X < 48" 36" MIN. 48"60" 180° TURN 180° TURN (EXCEPTION) 18" RECOMMENDED 15" MIN. 45" RECOMMENDED 48" MAX. ENVIRONMENTAL CONTROLS SUCH AS, BUT NOT LIMITED TO, THERMOSTATS AND OTHER HEATING, AIR-CONDITIONING, AND OTHER MECHANISMS MUST BE POSITIONED IN ACCESSIBLE LOCATIONS. 1/2" 1/4" 5" 1.SIGNAGE PROPORTION: LETTERS AND NUMBERS ON SIGNS SHALL HAVE A WIDTH-TO-HEIGHT RATIO BETWEEN 3:5 AND 1:1 AND A STROKE-WIDTH-TO-HEIGHT RATIO BETWEEN 1:5 AND 1:10. 2.CHARACTER HEIGHT: CHARACTERS AND NUMBERS ON SIGNS SHALL BE SIZED ACCORDING TO THE VIEWING DISTANCE FROM WHICH THEY ARE TO BE READ. THE MINIMUM HEIGHT IS MEASURED USING AN UPPER CASE X. LOWER CASE CHARACTERS ARE PERMITTED. 3 INCH MININUM HEIGHT. 3.RAISED AND BRAILLED CHARACTER AND PICTORIAL SYMBOL SIGNS: LETTERS AND NUMERALS SHALL BE RAISED 1/32 INCH IN UPPER CASE SANS SERIF OR SIMPLE SERIF TYPE AND SHALL BE ACCOMPANIED WITH GRADE 2 BRAILLE. RAISED CHARACTERS SHALL BE AT LEAST 5/8 INCH HIGH, BUT NO HIGHER THAN 2 INCHES. PICTOGRAMS SHALL BE ACCOMPANIED BY THE EQUIVALENT VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE PICTOGRAM. THE BORDER DIMENSION OF THE PICTOGRAM SHALL BE 6 INCHES MINIMUM IN HEIGHT. 4.FINISH AND CONTRAST: THE CHARACTERS AND BACKGROUND OF SIGNS SHALL BE EGGSHELL, MATTE, OR OTHER NON-GLARE FINISH. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND - EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND. 5.MOUNTING LOCATION AND HEIGHT: WHERE PERMANENT INDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES, SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. WHERE THERE IS NO WALL SPACE TO THE LATCH SIDE OF THE DOOR, INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL. MOUNTING HEIGHT SHALL BE 60 INCHES ABOVE THE FINISH FLOOR TO THE CENTERLINE OF THE SIGN. MOUNTING LOCATION FOR SUCH SIGNAGE SHALL BE SO THAT A PERSON MAY APPROACH WITHIN 3 INCHES OF SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A DOOR. SIGNAGE GENERAL NOTES: MIN. 18" 3"-6" 33"-36"8"-10" MAX. 24" MIN. 24"12" MAX. 1.BATHTUB SEAT: AN IN-TUB SEAT OR A SEAT AT THE HEAD OF THE TUB SHALL BE PROVIDED AS SHOWN ABOVE. SEATS SHALL BE MOUNTED SECURELY AND SHALL NOT SLIP DURING USE. 2.SHOWER UNIT: A SHOWER SPRAY UNIT WITH A HOSE AT LEAST 60 INCHES LONG THAT CAN BE USED BOTH AS A FIXED SHOWER HEAD AND AS A HAND-HELD SHOWER SHALL BE PROVIDED. 3.BATHTUB ENCLOSURES: IF PROVIDED, ENCLOSURES FOR BATHTUBS SHALL NOT OBSTRUCT CONTROLS OR TRANSFER FROM WHEELCHAIRS ONTO BATHTUB SEATS OR INTO TUBS. ENCLOSURES ON BATHTUBS SHALL NOT HAVE TRACKS MOUNTED ON THEIR BATHTUB RIMS. (BATHTUB RIMS SHALL BE 17 INCHES TO 19 INCHES MEASURED FROM FLOOR TO TOP OF RIM.) BATHTUB GENERAL NOTES: CL LOCATION OF TUB CONTROLS 36" MIN. 16" 27" MAX. ABOVE GRAB BAR 48" MAX. WITH SEAT CL 33"-36" 38" MIN. 48" MAX. 15" MAX.15" MAX. MAX. 27" 38" MIN. 48" MAX. 38" MIN. 48" MAX. 15" MAX. 60" 30" INSIDE FACE OF FINISH 30" MIN. SE A T WA L L SI D E W A L L INSIDE FACE OF FINISH 60" MIN. 6" MAX. 6" MAX.IF NO SEAT PROVIDED 6" MAX. GRAB BARS 36" SI D E W A L L SI D E W A L L INSIDE FACE OF FINISH 60" MIN. 6" MAX. 6" MAX. 6" MAX. 24"-36" MIN. 36" 60" MIN. 1.THRESHOLDS: THRESHOLDS IN ROLL-IN-TYPE SHOWER COMPARTMENTS SHALL BE 1/2 INCH MAXIMUM IN HEIGHT IN ACCORDANCE WITH ANSI SECTION 303. IN TRANSFER-TYPE SHOWER COMPARTMENTS, THRESHOLDS 1/2 INCH MAXIMUM IN HEIGHT SHALL BE BEVELED, ROUNDED, OR VERTICAL. 2.FLOOR SLOPE: THE MAXIMUM SLOPE OF THE FLOOR SHALL BE 1/4 INCH PER FOOT IN ANY DIRECTION. WHERE DRAINS ARE PROVIDED, GRATE OPENINGS SHALL BE A MAXIMUM OF 1/4 INCH AND LOCATED FLUSH WITH THE FLOOR SURFACE. 3.ENCLOSURES: IF PROVIDED, ENCLOSURES FOR SHOWER STALLS SHALL NOT OBSTRUCT CONTROLS OR OBSTRUCT TRANSFER FROM WHEELCHAIRS ONTO SHOWER SEATS. SHOWER STALLS GENERAL NOTES: 60" MIN. 60" MIN. 84 1/2" MIN. 60" MIN. WIDTH DOOR 60" MIN. MIN. 18" MIN. 18" MIN. 18" 12" MIN. 48" MIN. 12" MIN.* *PROVIDE 12" CLEARANCE IF DOORS EQUIPED WITH BOTH LATCH & CLOSER.4 8" M IN. DOOR WIDTH PLUS 42" * *24" MINIMUM EXTERIOR & 18" MINIMUM INTERIOR BEYOND STRIKE EDGE OF A GATE OR DOOR ON THE SIDE TOWARD WHICH IT SWINGS. 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com DATE:DRAWN BY: CHK'D BY: REVISED: C: \ U s e r s \ m t a y l o r \ D o c u m e n t s \ 1 9 - 1 3 7 . 4 D u b u q u e C o o p e r a t i v e L i v i n g - D e t a c h e d _ I A - m t a y l o r . r v t 11 / 3 0 / 2 0 2 1 1 1 : 0 1 : 4 0 A M A000 19-137 ----PR O J E C T : WA U K E E CO O P C L U B H O U S E AR C H I T E C T U R A L GE N E R A L IN F O R M A T I O N 11/30/2021 MT KC CLEAR FLOOR SPACE AT WATER CLOSETS GRAB BARS & TOILET TISSUE DISPENSERS AT WATER CLOSETS 404.2.4.1 - MANEUVERING CLEARANCES AT DOORS 703.4.2 - LOCATION OF TACTILE SIGNS AT DOORS 703.4.1 - LOCATION OF TACTILE CHARACTERS A.F.F. 606 - LAVATORIES & SINKS CLEARANCES DRINKING FOUNTAIN/WATER COOLER CLEARANCES 307.2 WALL PROTRUSION & CEILING CLEARANCES 307.4 HEAD CLEARANCE 308.2.1 FORWARD READ308.2.2 FORWARD REACH @ COUNTER308.3.1 SIDE REACH LIMITS 608.2.1 - TRANSFER TYPE SHOWER 607.4.2 - BATHTUB WITHOUT SEAT607.4.1 - BATHTUB WITH SEAT WATER CLOSET - FRONT WATER CLOSET - SIDE TUB - CONTROL WALL TUB - BACK WALL TUB - SIDE WALL SHOWER - CONTROL WALL SHOWER - BACK WALL SHOWER - SEAT WALL GRAB BAR REINFORCING 607 -CLEARANCES FOR BATHTUBS SIGNAGE REQUIREMENTS 302.2 CARPET PILE HEIGHT 303.2 VERTICAL CHANGE IN LEVEL 303.3 BEVELED CHANGES IN LEVEL 302 & 303 -FLOOR SURFACES & CHANGES IN LEVEL 305.7 MANUVERING CLEARANCE IN AN ALCOVE 306.2 TOE CLEARANCE 306.3 KNEE CLEARANCE 403.5.1 CLEAR WIDTH AT 180° TURN OUTLET, CONTROLS & SWITCH HEIGHT EXTERIOR DOOR THRESHOLD EXPOSED PIPES & SURFACES: WATER SUPPLY AND DRAIN PIPES UNDER LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE PROTECTED AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES AND SINKS. 607.5 LOCATION OF BATHTUB CONTROLS 608.4.2 STANDARD ROLL-IN-TYPE SHOWER CONTROL 608.4.3 ALT. ROLL-IN-TYPE SHOWER CONTROL BACK WALL 608.4.3 ALT. ROLL-IN-TYPE SHOWER CONTROL SIDE WALL 608.4.1 TRANSFER-TYPE SHOWER CONTROLS 608.2.2 STANDARD ROLL-IN-TYPE SHOWER 608.2.3 ALTERNATE ROLL-IN-TYPE SHOWER 404.2.5 TWO DOORS IN A SERIES NOT FOR CONSTRUCTION REF. BUILDING CODE ANALYSIS - 2018 IBC PROJECT DESCRIPTION: 6,554 SF NEW CONSTRUCTION OF A ONE STORY ASSEMBLY AND BUSINESS SPACE BUILDING MATERIAL: CEMENT BOARD SIDING ON WOOD STUD WALLS WITH BATT INSULATION CHAPTER 3 -USE AND OCCUPANCY CLASSIFICATION: OCCUPANCY TYPE: MIXED USE, RUN AS NON-SEPARATED MOST RESTRICTIVE = A-3 A-3 ASSEMBLY B BUSINESS CHAPTER 4 -SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY N/A CHAPTER 5 -GENERAL BUILDING HEIGHTS AND AREAS ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE PER TABLE 504.3 -CONSTRUCTION TYPE V-B NON SPRINKLERED ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE 504.4 OCCUPANCY CLASSIFICATION TYPE OF CONSTRUCTION ACTUAL TYPE V-B = 1 STORY CHAPTER 6 -TYPES OF CONSTRUCTION General per Sec. 601 - FIRE-RESISTANT RATING REQUIREMENT FOR BUILDING ELEMENTS (HOURS) PER TABLE 601: CONSTRUCTION TYPE: TYPE V-B BUILDING ELEMENT RATING -HOURS PRIMARY STRUCTURAL FRAME 0 BEARING WALLS EXTERIOR BEARING WALL INTERIOR NON BEARING WALLS EXTERIOR NON BEARING WALLS INTERIOR FLOOR CONSTRUCTION ROOF CONSTRUCTION CONSTRUCTION CLASSIFICATION SECTION 602 - FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE ARE AS FOLLOW PER TABLE 602: BUILDING SEPARATION FIRE SEPARATION DISTANCE 1HR5 < X < 10 CHAPTER 7 -FIRE AND SMOKE PROTECTION FEATURES -MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION. TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENING FIRE SEPARATION DISTANCE DEGREE OF OPENING PROTECTION ALLOWABLE AREA 5 < X < 10 UNPROTECTED, NONSPRINKLERED 10% CHAPTER 9 -FIRE PROTECTION SYSTEMS PORTABLE FIRE EXTINGUISHERS 906 -PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED IN ALL OF THE FOLLOWING LOCATIONS: 1. IN GROUP A-3 & B OCCUPANCIES. DUBUQUE COOP CLUBHOUSE 0 0 0 0 0 0 OCCUPANCY CLASSIFICATION TYPE OF CONSTRUCTION ACTUAL TYPE V-B = 6,000 S.F. ALLOWABLE AREA FACTOR IN SQUARE FEET 506.2 V-B OCCUPANCY A-3/BTYPE OF CONSTRUCTION CHAPTER 8 -INTERIOR FINISHES GROUP INTERIOR EXIT STAIRWAYS AND RAMPS AND EXIT PASSAGEWAY A-3 NON SPRINKLERED -INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY PER TABLE 803.11 CORRIDORS AND ENCLOSURE FOR EXIT ACCESS STAIRWAYS AND RAMPS ROOM AND ENCLOSED SPACES A A C WALL AND CEILING FINISHES 803 INTERIOR WALL AND CEILING FINISHES MATERIALS SHALL BE CLASSIFIED FOR FIRE PERFORMANCE AND SMOKE DEVELOPMENT IN ACCORDANCE WITH SECTION 803.1.1 OR 803.1.2 INTERIOR WALL AND CEILING FINISH MATERIALS 803.1.1 INTERIOR WALL AND CEILING FINISH MATERIALS SHALL BE CLASSIFIED IN ACCORDANCE WITH ASTM E84 AND UL 723 CLASS A= FLAME SPREAD INDEX 0-25; SMOKE DEVELOPED INDEX 0-450 CLASS B= FLAME SPREAD INDEX 26-75; SMOKE DEVELOPED 0-450 CLASS C= FLAME SPREAD INDEX 76-200; SMOKE DEVELOPED 76-200 ROOM CORNER TEST FOR INTERIOR WALL OR CEILING FINISH MATERIALS. INTERIOR WALL OR CEILING FINISH MATERIALS SHALL BE PERMITTED TO BE TESTED IN ACCORDANCE WITH NFPA 286. -GENERAL REQUIREMENTS 906.2 PORTABLE FIRE EXTINGUISHERS SHALL BE SELECTED AND INSTALLED IN ACCORDANCE WITH THIS SECTION AND NFPA 10 CHAPTER 29-PLUMBING OCCUPANCY CLASSIFICATION TYPE OF CONSTRUCTION ACTUAL A-3 TYPE V-B = 40'NS A-3 NS A-3 NS Definitions per Sec. 702 -Fire separation distance is the distance measured from the building face to one of the following: 1. The closest interior lot line; 2.To the centerline of a street, an alley or public way; or 3. To an imaginary line between two buildings on the property. per Sec. 702.1 -Fire resistance rating is not required for exterior wall per table 601 & 602 Fire Walls per Sec. 706 -Not Applicable Fire Barriers per Sec. 707 Fire Partitions per Sec. 708 Floor and Roof Assemblies per sec. 711 -Not Applicable - Corridor walls - No fire resistance required by section 1020.1 -Not Applicable REQUIRED SEPARATION OF OCCUPANCIES -NON-SEPARATED OCCUPANCIES PER TABLE 508.4 (RUN AS NON-SEPARATED, MOST RESTRICTIVE = A-3 B A B C MINIMUM PLUMBING FACILITIES (SECTION 2902) (A-3) ASSEMBLY TOTAL OCCUPANTS: 232 (116 MALE, 116 FEMALE) WATER CLOSET:1 PER 125 (MEN) 1 PER 65 (WOMEN) LAVATORIES:1 PER 200 (EACH) DRINKING FOUNTAIN:1 PER 500 REQUIRED PROVIDED MALE FEMALE MALE FEMALE 2 1 2 1 WATER CLOSET: LAVATORIES: 2 1 2 1 CHAPTER 10 -MEANS OF EGRESS OCCUPANT LOAD PER SECTION 1004 SEE OCCUPANT LOAD TABLE MIN. NUMBER OF EXITS PER STORY PER TABLE 1006.3.1 EXIT AND EXIT ACCESS DOORWAY CONFIGURATION 1007 -THE DISTANCE OF EXITS SHALL BE APART EQUAL TO NOT LESS THAN ONE HALF OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING ACCESSIBLE MEANS OF EGRESS 1009 -ACCESSIBLE MEANS OF EGRESS 1009.2 EACH REQUIRED ACCESSIBLE MEANS OF EGRESS SHALL BE CONTINUOUS TO A PUBLIC WAY AND SHALL CONSIST OF ONE OR MORE OF THE FOLLOWING COMPONENTS. 1.ACCESSIBLE ROUTES COMPLYING WITH 1104 EXIT ACCESS TRAVEL DISTANCE 1017 -TRAVEL DISTANCE PER TABLE 1017.2: WITHOUT SPRINKLER SYSTEM (FEET) OCCUPANCY PROVIDED A-3 200 FEET 90 FEET OR LESS CORRIDORS WIDTH 1020.2 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS 1006 1006.3.1 OCCUPANT LOAD MIN. # OF EXITS OR ACCESS TO EXITS FROM STORY 1-500 2 PROVIDED 5 MEANS OF EGRESS ILLUMINATION 1008 -MEANS OF EGRESS ILLUMINATION SHALL BE PROVIDED IN THE MEANS OF EGRESS IN ACCORDANCE WITH SECTION 1008.2. UN PER EMERGENCY POWER, MEANS OF EGRESS ILLUMINATION SHALL COMPLY WITH SECTION 1008.3. *(5)ACCESSIBLE MEANS OF EGRESS PROVIDED IN THE BUILDING DOOR, GATES AND TURNSTILES 1010 - SIZE OF DOORS 1010.1.1 THE REQUIRED CAPACITY OF EACH DOOR OPENING SHALL BE SUFFICIENT FOR THE OCCUPANT LOAD THEREOF AND SHALL PROVIDE A MIN. CLEAR WIDTH OF 32". (ALL DOORS IN PROJECT ARE 34" CLEAR WIDTH OR WIDER) - THRESHOLD 1010.1.7 THRESHOLD AT DOORWAYS SHALL NOT EXCEED 1/2" ABOVE FINISH FLOOR OR LANDING. - HARDWARE 1010.1.9.1 DOOR HANDLE, PULL, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON DOORS REQUIRED TO BE ACCESSIBLE BY CHAPTER 11 SHALL NOT REQUIRED TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. - HARDWARE HEIGHT1010.1.9.2 DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES SHALL BE INSTALLED AT 34" MIN. AND 48" MAX. ABOVE FINISH FLOOR. OCCUPANCY A-3/B MIN. WIDTH 44" PROVIDED 60" CHAPTER 11-ACCESSIBILITY - SITE ARRIVAL POINTS 1104.1 AT LEAST ONE ACCESSIBLE ROUTE WITHIN THE SITE SHALL BE PROVIDED FROM PUBLIC TRANSPORTATION STOPS, ACCESSIBLE PARKING, ACCESSIBLE PASSENGER LOADING ZONES AND PUBLIC STREETS OR SIDEWALKS TO THE ACCESSIBLE BUILDING ENTRANCE SERVED. BUILDING IS DESIGNED IN ACCORDANCE WITH CHAPTER 11 OF THE 2015 IBC AS WELL AS THE 2010 ADA STANDARDS - PUBLIC ENTRANCE 1105.1 IN ADDITION TO ACCESSIBLE ENTRANCES REQUIRED BY SECTIONS 1105.1.1 THROUGH 1005.1.7, AT LEAST 60 PERCENT OF ALL PUBLIC ENTRANCES SHALL BE ACCESSIBLE OTHER FEATURES AND FACILITIES 1109 TOILET AND BATHING FACILITIES 1109.2 . EACH TOILET ROOM AND BATHING ROOM SHALL BE ACCESSIBLE. EXCEPTIONS 1. TOILET ROOMS ACCESSED ONLY THROUGH A PRIVATE OFFICE, NOT FOR COMMON PUBLIC USE AND INTENDED FOR USE BY SINGLE OCCUPANT, SHALL BE PERMITTED TO COMPLY WITH THE SPECIFIC EXCEPTIONS IN ICC A117.1 MEANS OF EGRESS SIZING 1005 - CALCULATIONS PER SECTION BELOW 1005.3.2 OCC. Load Exit (inches) REQ'D Provided 232 232X0.2 = 46.4" 252" B 200 FEET 90 FEET OR LESS 6,554 S.F. B TYPE V-B = 40'NS TYPE V-B = 2 STORYBNS TYPE V-B = 9,000 S.F.B NS 6,554 S.F. 29'-6" 29'-6" 1 STORY 1 STORY -FIRE EXTINGUISHERS MAX DISTANCE = 75'-0" NUMBER REQUIRED = 1 "A" PER 1,500 SF = 3 (A=1 1/4 EFFECTIVE GAL.) NUMBER PROVIDED = 3A REQ'D = (3) 2-A FEC PROVIDED REQUIRED PROVIDED 1 DRINKING FOUNTAIN:2 0HR10 < X < 30 V-B 10 < X < 15 UNPROTECTED, NONSPRINKLERED 15% 15 < X < 20 UNPROTECTED, NONSPRINKLERED 25% 20 < X < 25 UNPROTECTED, NONSPRINKLERED 45% 25 < X < 30 UNPROTECTED, NONSPRINKLERED 70% 30 < X UNPROTECTED, NONSPRINKLERED NO LIMIT W=(L1*w1+L2*w2+L3*w3+L4*w4)/F W=(77.5*25.75+129.8*10+77.5*41+129.8* 66.5)/414.66 W=36.43=30 If=[(F/P)-0.25]W/30 If=[(414.66/414.66)-0.25]30/30 If=0.75 Aa=[At+(Ns*If)] Aa=[6,000+(6000*0.75)] Aa=10,500 sqft ALLOWABLE AREA MINIMUM FRONTAGE DISTANCE AREA FACTOR INCREASE DUE TO FRONTAGE ALLOWABLE AREA A=6,554 S.F. AREA PROVIDED RATING DESCRIPTION USE 1 HR PLAN INDICATOR LINE STYLE SEPARATION DESIGNATION WALL RATING INDICATORS AND CODES FIRE WALLFW-1HR EXTERIOR WALL TRAVEL DISTANCE -ACTUAL: 20'-0" LIFE SAFETY PLAN SYMBOLS LEGEND EXIT PATH AND ASSOCIATED TRAVEL DISTANCE FIRE EXTINGUISHER F.E. EGRESS LENGTH: 43'-8" EGRESS LENGTH: 83'-4" EGRESS LENGTH: 45'-10" EGRESS LENGTH: 85'-5" F.E. F.E. F.E. EGRESS LENGTH: 38'-9" COMMON PATH: 67'-10" COMMON PATH: 42'-2" COMMON PATH: 29'-6" 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com DATE:DRAWN BY: CHK'D BY: REVISED: C: \ U s e r s \ m t a y l o r \ D o c u m e n t s \ 1 9 - 1 3 7 . 4 D u b u q u e C o o p e r a t i v e L i v i n g - D e t a c h e d _ I A - m t a y l o r . r v t 11 / 3 0 / 2 0 2 1 1 1 : 0 1 : 4 2 A M A010 19-137 ---- CO D E P L A N S RE V I E W 11/30/2021 MT KC OCCUPANT LOAD SCHEDULE PER SECTION 1004 NO. ROOM NAME AREA SPACE FUNCTION AREA PER OCCUPANT Area Unit OCC Exit Width MAIN LEVEL 100 VESTIBULE 208 SF Assembly without fixed seats - Unconcentrated (tables and chairs)15 SF Net 14 2.8 101 COFFEE LOUNGE 176 SF Assembly without fixed seats - Unconcentrated (tables and chairs)15 SF Net 12 2.4 102 FIREPLACE LOUNGE 644 SF Assembly without fixed seats - Unconcentrated (tables and chairs)15 SF Net 43 8.6 103 OFFICE 173 SF Business areas 100 SF Gross 2 0.4 104 GAMES 348 SF Assembly without fixed seats - Unconcentrated (tables and chairs)15 SF Net 24 4.8 105 MEETING 1,264 SF Assembly without fixed seats - Unconcentrated (tables and chairs)15 SF Net 85 17 106 EXERCISE 364 SF Exercise rooms 50 SF Gross 8 1.6 107 RR 112 SF -Not Counted 0 SF 108 RR 112 SF -Not Counted 0 SF 109 MECH 102 SF Accessory storage areas, mechanical equipment room 300 SF Gross 1 0.2 110 JAN.42 SF Accessory storage areas, mechanical equipment room 300 SF Gross 1 0.2 111 OUTDOOR STORAGE 114 SF Accessory storage areas, mechanical equipment room 300 SF Gross 1 0.2 112 HALLWAY 174 SF -Not Counted 0 SF 113 PICKLEBALL 1,994 SF Exercise rooms 50 SF Gross 40 8 114 STOR.35 SF Accessory storage areas, mechanical equipment room 300 SF Gross 1 0.2 232 46.4 TOTAL OCC.232 46.4 1/16" = 1'-0"3 LIFE SAFETY PLAN 5,859 SF 150 NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E REF. A200 4 A200 3 A200 2 A200 1 A100 5 1 A300 1 A300 3 A300 3 A300 W3 W4 W4 W2 W2 W2 W2 W1 W1 W1 W1 W1W1 W1 W6 W6 W1 GAMES 104 FIREPLACE LOUNGE 102 MEETING 105 PICKLEBALL 113 HALLWAY 112 EXERCISE 106 OFFICE 103 W3 2 A300 2 A300 W3 100.1 114.1 102.1 106.1 107.1 108.1 110.1 109.1 111.1 112.2 113.1 112.3 113.2 OUTDOOR STORAGE 111 JAN. 110 MECH 109 RR 108 RR 107 E6A E4A E3AE3A P1A P1A P1A E3A E2A E3A E7A P1A E7A P2A P2AP2A P2B P2B P2B P2A E6A E3A E3A E3A E1A E1A P1A P1A P1A P1A P1A P1A P1A P3A E8A E8A P3AP1A P3A P3A P1A E1A E1A E9A P1A P1A P1A A101 1 A102 1 78'-5" 51'-5" 129'-10" 16'-5"16'-6"28'-5"16'-2" 16'-5"16'-6"7'-3"35'-4"2'-0" W5 W5 47'-4" 2'-0" 80'-6" 129'-10" STOR. 114 112.1 2'-0" 2'-0" 77'-6" 2 A301 2 A301 77'-6" E6A P1A P1A 105.1 VESTIBULE 100 COFFEE LOUNGE 101 103.1 POOL 18X30 A103 1 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS, DISCIPLINES AND SPECIFICATIONS. 2. USE DIMENSIONAL INFORMATION GIVEN. DO NOT SCALE DRAWINGS. 3. EXTERIOR DIMENSIONS ARE TYPICALLY INDICATED TO THE EXTERIOR FACE OF THE STRUCTURE/GRID LINE UNLESS OTHERWISE NOTED. 4. INTERIOR PARTITION DIMENSIONS ARE TYPICALLY INDICATED TO THE STUD FACE UNLESS OTHERWISE NOTED. 5. ALL SITE INFO, FIXTURES AND EQUIPMENT SHOWN ON THIS SHEET IS PROVIDED FOR COORDINATION PURPOSES ONLY. THE LAYOUT IS CONSIDERED CONCEPTUAL. REFER TO CIVIL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE SPRINKLER, LIFE-SAFETY, ETC. DOCUMENTS FOR SPECIFIC DESIGN INFORMATION. 6. PROVIDE ADEQUATE BLOCKING FOR ALL CABINETS, RESTROOM FIXTURES, AND EQUIPMENT. 7. FOR WALL TYPES NOT SEEN ON PLAN REFER TO WALL SECTIONS AND DETAILS. 8. REFER TO ENLARGED PLANS IF ITS AVAILABLE FOR ADDITIONAL EXTERIOR AND INTERIOR INFORMATION. 9. BUILDING STRUCTURAL ELEMENTS SUCH MAIN FRAMES AND COLUMNS ARE SHOWN FOR REFERENCE ONLY. SEE STRUCTURAL DRAWINGS FOR DETAILS FLOOR PLAN GENERAL NOTE: MARK WALL LAYERS DESCRIPTION FIRE RATING RATING SOURCE SOUND RATING RATING SOURCE NOTE EXTERIOR WALLS LEGEND - WOOD STUDS E 1 A -- -- ---- (EXTERIOR) 6" HORIZONTAL SIDING(WOOD OR CONCRETE) CONTINUOUS WEATHER BARRIER 5/8" PLYWOOD SHEATHING 2X6 WOOD STUDS @ 16" O.C. R-20 BATT INSULATION (INTERIOR) 5/8" GYPSUM WALL PANELS NOTE: WALL TO UNDERSIDE OF STRUCTURE E 3 A -- -- ---- (EXTERIOR) 12" VERTICAL SIDING(WOOD OR CONCRETE) CONTINUOUS WEATHER BARRIER 5/8" PLYWOOD SHEATHING 2X6 WOOD STUDS @ 16" O.C. R-20 BATT INSULATION (INTERIOR) 5/8" GYPSUM WALL PANELS NOTE: WALL TO UNDERSIDE OF STRUCTURE E 4 A -- -- ---- (EXTERIOR) WATER REPELLENT STONE VENEER DRAINAGE MAT 1 1/2" AIR SPACE CONTINUOUS WEATHER BARRIER 5/8" OSB SHEATHING 2X6 WOOD STUDS @ 16" O.C. R-20 BATT INSULATION (INTERIOR) 5/8" GYPSUM WALL PANELS NOTE: WALL TO UNDERSIDE OF STRUCTURE E 5 B -- -- ---- (EXTERIOR) WATER REPELLENT STONE VENEER DRAINAGE MAT 1 1/2" AIR SPACE CONTINUOUS WEATHER BARRIER 6X8X16 CMU NOTE: WALL TO 3'-4" 9 3/8" 10 3/8" 7 1/4" 7 1/4" E 6 A -- -- ---- (EXTERIOR) 6" HORIZONTAL SIDING(WOOD OR CONCRETE) CONTINUOUS WEATHER BARRIER 5/8" OSB SHEATHING 2X6 WOOD STUDS @ 16" O.C. R-20 BATT INSULATION 5/8" OSB SHEATHING (INTERIOR) 5/8" GYPSUM WALL PANELS NOTE: WALL TO UNDERSIDE OF STRUCTURE 8 1/2" E 7 A -- -- ---- (EXTERIOR) 12" VERTICAL SIDING(WOOD OR CONCRETE) CONTINUOUS WEATHER BARRIER 5/8" OSB SHEATHING 2X6 WOOD STUDS @ 16" O.C. R-20 BATT INSULATION (INTERIOR) 5/8" GYPSUM WALL PANELS NOTE: WALL TO UNDERSIDE OF STRUCTURE 7 1/4" E 8 A -- -- ---- (EXTERIOR) 12" VERTICAL SIDING(WOOD OR CONCRETE) CONTINUOUS WEATHER BARRIER 5/8" OSB SHEATHING 2X6 WOOD STUDS @ 16" O.C. R-20 BATT INSULATION 6" CMU BLOCK; GROUT CORES SOLID 7/8" HAT CHANNEL (INTERIOR) 5/8" GYPSUM WALL PANELS NOTE: WALL TO UNDERSIDE OF STRUCTURE 1'-1 3/4" E 2 A -- -- ---- (EXTERIOR) 6" HORIZONTAL SIDING(WOOD OR CONCRETE) CONTINUOUS WEATHER BARRIER 5/8" OSB SHEATHING 2X6 WOOD STUDS @ 16" O.C. R-20 BATT INSULATION 5/8" OSB SHEATHING (INTERIOR) 5/8" GYPSUM WALL PANELS NOTE: WALL TO UNDERSIDE OF STRUCTURE 7 7/8" E 9 A -- -- ---- (EXTERIOR) 6" HORIZONTAL SIDING(WOOD OR CONCRETE) CONTINUOUS WEATHER BARRIER 5/8" OSB SHEATHING 2X8 LSL STUDS @ 16" O.C. R-20 BATT INSULATION 5/8" OSB SHEATHING (INTERIOR) 5/8" GYPSUM WALL PANELS NOTE: WALL TO UNDERSIDE OF STRUCTURE 9 5/8" MARK WALL LAYERS DESCRIPTION FIRE RATING RATING SOURCE SOUND RATING RATING SOURCE NOTE INTERIOR WALLS LEGEND - WOOD STUDS P 1 A -- -- ---- (EXTERIOR) 5/8" GYPSUM WALL PANELS 2X6 WOOD STUDS @ 16" O.C. BATT INSULATION (INTERIOR) 5/8" GYPSUM WALL PANELS NOTE: WALL TO UNDERSIDE OF STRUCTURE P 2 A -- -- ---- (EXTERIOR) STONE VENEER MORTAR 5/8" OSB SHEATHING 2X4 WOOD STUDS @ 16" O.C. BATT INSULATION NOTE: WALL TO UNDERSIDE OF STRUCTURE P 2 B -- -- ---- (EXTERIOR) STONE VENEER MORTAR 5/8" OSB SHEATHING 2X4 WOOD STUDS @ 16" O.C. BATT INSULATION NOTE: WALL TO UNDERSIDE OF STRUCTURE 6 3/4" 6 3/8" 6 3/8" P 3 A -- -- ---- (EXTERIOR) 5/8" GYPSUM WALL PANELS 7/8" HAT CHANNEL @ 16" O.C. 6" CMU BLOCK; GROUT CORES SOLID 7/8" HAT CHANNEL @ 16" O.C. 5/8" GYPSUM WALL PANELS MORTAR (RESTROOM) CERAMIC TILE NOTE: WALL TO UNDERSIDE OF STRUCTURE 8 5/8" 4 A100 FILL CAVITY WITH 6"X8"X8" CMU BLOCKS 1'-1"1'-1" 2'-2" 2'-2" 1'-1" 1'-1" E5B E5B E5B E5B MAIN LEVEL100'-0" MANUFACTURED CAST STONE CAP FILL CAVITY WITH 6"X8"X8" CMU BLOCK 6"X8"X16" CMU 1 1/2" AIR SPACE STONE VENEER W/ WATER REPELLENT FOUNDATION BELOW 3'-0" 2" 2" 5'-9" 2" 3" DECORATIVE COLUMN WRAP STRUCTURAL COLUMN 1X3 TRIM 2 3/4"1'-6"2 3/4" 3'-0" 6'-6" 1/8" = 1'-0"1 MAIN FLOOR PLAN 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com DATE:DRAWN BY: CHK'D BY: REVISED: C: \ U s e r s \ m t a y l o r \ D o c u m e n t s \ 1 9 - 1 3 7 . 4 D u b u q u e C o o p e r a t i v e L i v i n g - D e t a c h e d _ I A - m t a y l o r . r v t 11 / 3 0 / 2 0 2 1 1 1 : 0 1 : 4 3 A M A100 19-137 ---- MA I N F L O O R P L A N 11/30/2021 MT KC 1/2" = 1'-0"5 COLUMN-PLAN TYP. 1/2" = 1'-0"4 COLUMN-SECTION TYP. N NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E REF. 4 A100 1 A300 1 A300 GAMES 104 FIREPLACE LOUNGE 102 MEETING 105 8'-5"8'-0"8'-3"8'-3"11'-4"9'-5"7'-8"2'-1"12'-0"2'-1" 2'-0" 2'-2" 7'-0" 2'-0" 30'-3" 7'-9" 7'-4" 2'-0" 51'-5" OUTDOOR STORAGE 111 JAN. 110 MECH 109 RR 108 RR 107 EXERCISE 106 STOR. 114 OFFICE 103 100.1 114.1 102.1 111.1 110.1 109.1 108.1 107.1 106.1 A400 1 2'-0"6'-2 3/8" 14'-9"5 1/2"5'-6"5 1/2"4'-7 1/8"5 1/2"8'-2 3/8" 2'-0" 2'-0" 24'-2 7/8" 5 5/8" 12'-5" 5 5/8" 12'-5 1/4" 5 5/8" 13'-11" 3'-3 1/2"5 1/2"24'-8"5 1/2"15'-3" 5 1/2" 4'-0" 7'-10 5/8" A401 1 A401 2 5'-9" 5'-9" 15'-11 1/2"5 1/2"19'-9 1/2"24'-8"5 1/2"15'-3" 11'-0 1/2" 5 1/2" 11'-6" W2 W2 W2 W2 W1 W4 W4 W3 W3 5'-2" 4'-6" 8'-5"8'-0"8'-3"8'-3"7'-3"35'-4"2'-0" 16'-5"16'-6"7'-3"35'-4"2'-0" 12'-5 1/2" 8'-0" 12'-5 1/2" 31'-7 3/4"1'-9 3/4"2'-6 3/4"24'-10 1/4"5 1/2"4'-8" 5 5/8" 9'-7 3/4" 5'-0" 13'-0" 5 1/2" 7'-10 5/8" 16'-5"16'-6"28'-5"16'-2" P2B P2B P2A P2AP2A P2B P2A P1A P3A P3A P3AP1A 2'-0" E8A E8A E7A E2AW3 E7A 7'-0" 2'-2" 1'-11 7/8" 2'-2"15'-9 5/8"2'-2"10'-10"2'-2"7'-11"5 1/2" E5B E5B E5B E5B E5B E5B E5B E5B E5B E5B E5B E5B 2'-2"7'-1 1/2"8'-0"8"2'-2"5'-5"5'-5"2'-2"8" 2'-2" 9'-0" 2'-0" E1AE3A E3A E3AE6A E6A E4A P1A P1A E3A E3A E3A P1A P1A P1A P3A P1A P1A P1A P1A P1A P1A P1A E1A 25'-10 1/2" 4'-4 1/2" 9'-6 1/2" W5 W5 4 A312 2 A311 1 A311 2 A312 E7A 3 A311 4 A311 3 A312 1 A310 A600 7 A600 4 A600 5 A600 3 A600 6 A4025 E5B E5BE5B E5B E5B E5B E5BE5B E5BE5B E5B E5B 3 A310 2'-0" 2 A301 2 A301 2 A310 1 A301 1 A301 4'-0" 4'-0" 11'-0 1/2" 5 1/2" 21'-5" 32'-0" 103.1 P1A A4026 VESTIBULE 100 COFFEE LOUNGE 101 105.1 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS, DISCIPLINES AND SPECIFICATIONS. 2. USE DIMENSIONAL INFORMATION GIVEN. DO NOT SCALE DRAWINGS. 3. EXTERIOR DIMENSIONS ARE TYPICALLY INDICATED TO THE EXTERIOR FACE OF THE STRUCTURE/GRID LINE UNLESS OTHERWISE NOTED. 4. INTERIOR PARTITION DIMENSIONS ARE TYPICALLY INDICATED TO THE STUD FACE UNLESS OTHERWISE NOTED. 5. ALL SITE INFO, FIXTURES AND EQUIPMENT SHOWN ON THIS SHEET IS PROVIDED FOR COORDINATION PURPOSES ONLY. THE LAYOUT IS CONSIDERED CONCEPTUAL. REFER TO CIVIL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE SPRINKLER, LIFE-SAFETY, ETC. DOCUMENTS FOR SPECIFIC DESIGN INFORMATION. 6. PROVIDE ADEQUATE BLOCKING FOR ALL CABINETS, RESTROOM FIXTURES, AND EQUIPMENT. 7. FOR WALL TYPES NOT SEEN ON PLAN REFER TO WALL SECTIONS AND DETAILS. 8. REFER TO ENLARGED PLANS IF ITS AVAILABLE FOR ADDITIONAL EXTERIOR AND INTERIOR INFORMATION. 9. BUILDING STRUCTURAL ELEMENTS SUCH MAIN FRAMES AND COLUMNS ARE SHOWN FOR REFERENCE ONLY. SEE STRUCTURAL DRAWINGS FOR DETAILS FLOOR PLAN GENERAL NOTE: 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com DATE:DRAWN BY: CHK'D BY: REVISED: C: \ U s e r s \ m t a y l o r \ D o c u m e n t s \ 1 9 - 1 3 7 . 4 D u b u q u e C o o p e r a t i v e L i v i n g - D e t a c h e d _ I A - m t a y l o r . r v t 11 / 3 0 / 2 0 2 1 1 1 : 0 1 : 4 5 A M A101 19-137 ---- MA I N F L O O R P L A N 11/30/2021 MT KC 1/4" = 1'-0"1 MAIN LEVEL PLAN-LOUNGEN NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E 3 A300 3 A300 2 A300 2 A300 PICKLEBALL 113 HALLWAY 112 5 1/2" 5'-2" 5 1/2" 58'-3 1/4" 23'-5"11'-0" 34'-5" 113.1 112.3 112.2 113.2 7'-8" 12'-0" 4'-0" 3'-10" 2'-2" 2'-2" 3'-10" 4'-0" 12'-0" 10'-10" 3'-6"12'-0"4'-4"12'-0"3'-6" 35'-4" 7'-8" 12'-0" 4'-0" 12'-0" 4'-0" 12'-0" 9'-8" W6 W1 W1 W1 W1W1 W1 W1 W6 P1A P1A E1A E1A E9A 2'-0" 2'-0" 5 A312 A600 8 1 A312 EQ.EQ. EQ. EQ. 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS, DISCIPLINES AND SPECIFICATIONS. 2. USE DIMENSIONAL INFORMATION GIVEN. DO NOT SCALE DRAWINGS. 3. EXTERIOR DIMENSIONS ARE TYPICALLY INDICATED TO THE EXTERIOR FACE OF THE STRUCTURE/GRID LINE UNLESS OTHERWISE NOTED. 4. INTERIOR PARTITION DIMENSIONS ARE TYPICALLY INDICATED TO THE STUD FACE UNLESS OTHERWISE NOTED. 5. ALL SITE INFO, FIXTURES AND EQUIPMENT SHOWN ON THIS SHEET IS PROVIDED FOR COORDINATION PURPOSES ONLY. THE LAYOUT IS CONSIDERED CONCEPTUAL. REFER TO CIVIL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE SPRINKLER, LIFE-SAFETY, ETC. DOCUMENTS FOR SPECIFIC DESIGN INFORMATION. 6. PROVIDE ADEQUATE BLOCKING FOR ALL CABINETS, RESTROOM FIXTURES, AND EQUIPMENT. 7. FOR WALL TYPES NOT SEEN ON PLAN REFER TO WALL SECTIONS AND DETAILS. 8. REFER TO ENLARGED PLANS IF ITS AVAILABLE FOR ADDITIONAL EXTERIOR AND INTERIOR INFORMATION. 9. BUILDING STRUCTURAL ELEMENTS SUCH MAIN FRAMES AND COLUMNS ARE SHOWN FOR REFERENCE ONLY. SEE STRUCTURAL DRAWINGS FOR DETAILS FLOOR PLAN GENERAL NOTE: 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com DATE:DRAWN BY: CHK'D BY: REVISED: C: \ U s e r s \ m t a y l o r \ D o c u m e n t s \ 1 9 - 1 3 7 . 4 D u b u q u e C o o p e r a t i v e L i v i n g - D e t a c h e d _ I A - m t a y l o r . r v t 11 / 3 0 / 2 0 2 1 1 1 : 0 1 : 4 6 A M A102 19-137 ---- MA I N F L O O R P L A N 11/30/2021 MT KC 1/4" = 1'-0"1 MAIN LEVEL PLAN-PICKLEBALL COURTN NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E POOL 18X30 23'-8 7/8" 30'-0" 20'-0" 12'-11 5/8"18'-0"11'-6" 42'-5 5/8" 73'-8 7/8" PANIC HARDWARE APPLIED TO GATE CONCRETE PATH BY CONTRACTOR 2'-3" 1'-0" 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com DATE:DRAWN BY: CHK'D BY: REVISED: C: \ U s e r s \ m t a y l o r \ D o c u m e n t s \ 1 9 - 1 3 7 . 4 D u b u q u e C o o p e r a t i v e L i v i n g - D e t a c h e d _ I A - m t a y l o r . r v t 11 / 3 0 / 2 0 2 1 1 1 : 0 1 : 4 7 A M A103 19-137 ---- MA I N F L O O R P L A N 11/30/2021 MT KC 1/4" = 1'-0"1 POOL PLANN NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E CEILING GENERAL NOTES: 1.REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS, DISCIPLINES AND SPECIFICATIONS. 2.PAINT ALL GYPSUM BOARD CEILINGS. SEE FINISH SCHEDULE. 3.REFER TO ELECTRICAL DRAWINGS AND FIRE PROTECTION DRAWING FOR FIXTURE AND EQUIPMENT TYPE. 4.REFER TO MECHANICAL, PLUMBING, ELECTRICAL, AND FIRE PROTECTION DRAWINGS FOR ADDITIONAL INFORMATION. 5.CEILING HEIGHTS ARE SHOWN ON THE REFLECTED CEILING PLAN. 6.ALIGN CEILING GRID IN ROOMS WITH ACOUSTIC CEILING TILE CEILING SYSTEM AS SHOWN ON CEILING PLAN. PLACE ALL CEILING MOUNTED EQUIPMENT IN THE CENTER OF THE CEILING TILE UNLESS OTHERWISE NOTED. COORDINATE ALL DISCREPANCIES WITH ARCHITECT PRIOR TO INSTALLATION. 7.SEE INTERIOR ELEVATIONS / SECTIONS / DETAILS FOR ADDITIONAL INFORMATION ON FINISHED SOFFIT, BULKHEAD, CEILING, ETC. WHERE NOT INDICATED ON REFLECTED CEILING PLAN. CEILING LEGEND: GYPSUM BOARD CEILING VENTED METAL SOFFIT 10'-0 1/2"11'-0" 12'-0" 10'-0 1/2"8'-0"10'-0 1/2" 23'-8 43/64"13'-0"13'-0" 8'-0" 10'-0 1/2" 7 1/2" / 1'-0"7 1/2" / 1'-0" 14'-0" 10'-0 1/2" 9'-1 7/8" 9'-1 7/8" 10'-0 1/2" PICKLEBALL 113 HALLWAY 112 MECH 109 JAN. 110 OUTDOOR STORAGE 111 RR 108 RR 107 EXERCISE 106 MEETING 105 FIREPLACE LOUNGE 102 GAMES 104 1'-9 1/2"11'-10 7/8"3'-0 3/4" 3'-0 1/2" 2'-0"20'-6 3/4"2'-0" 1'-9 1/2"5'-11 1/2"5'-11 1/2"3'-0 3/4" 18'-1 7/8" 1'-5 3/8"13'-5"3'-3 1/2" 1'-6" 18'-3 1/8" 1'-6" 14'-0" 7 1/2" / 1'-0"7 1/2" / 1'-0" OFFICE 103 10'-0 1/2" 21'-11 1/8" 30'-0" 2'-0" 10'-0 1/2" LVL BEAM WITH 1" SMOOTH CEDAR WRAP; COLOR BY OWNER LVL BEAM WITH 1" SMOOTH CEDAR WRAP; COLOR BY OWNER 9'-6"9'-6" 9'-6" 9'-6 1/2" 10'-0 1/2" 10'-0 1/2" 3X3 ACCESS; COORD. W/ ELECTRICAL BEADBOARD (WHITE PINE CARSIDING) SOFFIT BEADBOARD (WHITE PINE CARSIDING) SOFFIT VENTED ALUMINUM SOFFIT VENTED ALUMINUM SOFFIT VENTED ALUMINUM SOFFIT VENTED ALUMINUM SOFFITVENTED ALUMINUM SOFFIT VENTED ALUMINUM SOFFIT VENTED ALUMINUM SOFFIT VENTED ALUMINUM SOFFIT 9'-6" 9'-6" 7 1/2" / 1'-0" 9'-6"9'-6" LVL BEAM WITH 1" SMOOTH CEDAR WRAP; COLOR BY OWNER LVL BEAM WITH 1" SMOOTH CEDAR WRAP; COLOR BY OWNER 10'-0 1/2"10'-0 1/2" 7 1/2" / 1'-0" 7 1/2" / 1'-0"7 1/2" / 1'-0" 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com DATE:DRAWN BY: CHK'D BY: REVISED: C: \ U s e r s \ m t a y l o r \ D o c u m e n t s \ 1 9 - 1 3 7 . 4 D u b u q u e C o o p e r a t i v e L i v i n g - D e t a c h e d _ I A - m t a y l o r . r v t 11 / 3 0 / 2 0 2 1 1 1 : 0 1 : 4 8 A M A120 19-137 ---- RE F L E C T E D C E I L I N G PL A N 11/30/2021 MT KC 1/8" = 1'-0"1 REFLECTED CEILING PLANN NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E 7 1/2" / 1'-0"7 1/2" / 1'-0" 7 1/2" / 1'-0" 4" / 1'-0" 4" / 1'-0" 3 1/2" / 1'-0" 7 1/2" / 1'-0" 7 1/2" / 1'-0" 7 1/2" / 1'-0" 7 1/2" / 1'-0"VALLEYVALLEYVALLEYVALLEYVALLEYVALLEYVALLEYV A L L E Y 1'-0" 1'-0" 1'-6"1'-6" 1'-0" 1'-0" RIDGE 1'-6" 1'-0" 1'-6" 1'-0" 1'-0"1'-0" 1'-6" RI D G E RI D G E HIP H I P VALLEY RI D G E RI D G E 2 4 2 2 2 2 2 2 2 2 11 11 5 1 1 1 111 1 1 11 RI D G E RI D G E 5 7 1/2" / 1'-0" 7 1/2" / 1'-0" ROOF PLAN NOTES 1. DOWNSPOUT LOCATION A. TIE ALL DOWNSPOUTS TO SUB DRAIN SYSTEM DESIGNED BY CIVIL ENGINEER 2. CONTINUOUS RIDGE VENT 3. ASHPALT SHINGLES TO COVER ENTIRETY OF ROOF 4. DRAFT STOP, GYP. BOARD APPLIED TO GABLE END ROOF TRUSS BELOW 5. GIRDER TRUSS 6. GABLE-END TRUSS 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com DATE:DRAWN BY: CHK'D BY: REVISED: C: \ U s e r s \ m t a y l o r \ D o c u m e n t s \ 1 9 - 1 3 7 . 4 D u b u q u e C o o p e r a t i v e L i v i n g - D e t a c h e d _ I A - m t a y l o r . r v t 11 / 3 0 / 2 0 2 1 1 1 : 0 1 : 4 9 A M A130 19-137 ---- RO O F P L A N 11/30/2021 MT KC 1/8" = 1'-0"1 ROOF PLANN NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E 1.ARCHITECTURAL 100' -0" = SURVEY XXXX.XX' 2.DO NOT SCALE DRAWINGS. DRAWN DIMENSIONS SHALL TAKE PRECEDENCE. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES IMMEDIATELY. 3.REFER TO DOOR AND WINDOW SCHEDULES FOR MORE INFORMATION. 4.SEE CIVIL DRAWINGS FOR DRAINAGE REQUIREMENTS. 5.GRADE SOIL AWAY FROM BUILDING TO DRAIN. SEE CIVIL AND LANDSCAPE DRAWINGS FOR MORE INFORMATION. ELEVATION GENERAL NOTES MAIN PLT. HT.110'-1 1/8" ALUMINUM FASCIA GUTTER ALUMINUM FASCIA COLUMN STONE VENEER COLUMN BASE ASPHALT SHINGLES ASPHALT SHINGLE ALUMINUM FASCIA 6" HORIZONTAL WOOD OR CONCRETE SIDING PELLA WINDOWS W/ 5/4X4 TRIM;TYP. DOWNSPOUT PICKLEBALL PLT. HEIGHT113'-0 3/4"5/4X4 CORNER TRIM; TYP. 5/4X6 FRIEZE BOARD;TYP. DOUBLE FRIEZE BOARD (2) 5/4X6 6" HORIZONTAL WOOD OR CONCRETE SIDING FAUX TIMBER 5/4X6 FRIEZE BOARD 5/4X4 CORNER TRIM EXPOSED FOUNDATION PELLA WINDOWS W/ 5/4X4 TRIM FENCE MAIN PLT. HT.110'-1 1/8" ASPHALT SHINGLE DOWNSPOUT ALUMINUM FASCIA GUTTER 6" HORIZONTAL WOOD OR CONCRETE SIDING 6" HORIZONTAL WOOD OR CONCRETE SIDING ALUMINUM FASCIA COLUMN STONE VENEER COLUMN BASE 6" HORIZONTAL WOOD OR CONCRETE SIDING PICKLEBALL PLT. HEIGHT113'-0 3/4" 5/4X6 FRIEZE BOARD FAUX TIMBER PELLA WINDOWS W/ 5/4X4 TRIM 5/4X4 CORNER TRIM; TYP. 5/4X6 FRIEZE BOARD; TYP. EXPOSED FOUNDATIONFENCE MAIN PLT. HT.110'-1 1/8" ASPHALT SHINGLE GUTTER ALUMINUM FASCIA DOWNSPOUT PELLA WINDOWS W/ 5/4X4 TRIM 6" HORIZONTAL WOOD OR CONCRETE SIDING STONE VENEER COLUMN BASE COLUMN ALUMINUM FASCIA GUTTER 12" VERTICAL WOOD OR CONCRETE SIDING ALUMINUM FASCIA PICKLEBALL PLT. HEIGHT113'-0 3/4" FAUX TIMBER BRACKET 5/4X4 CORNER TRIM; TYP. 5/4X6 FRIEZE BOARD; TYP. EXPOSED FOUNDATION FAUX TIMBER 5/4X4 CORNER TRIM; TYP. 5/4X6 FRIEZE BOARD; TYP. MAIN PLT. HT.110'-1 1/8" ASPHALT SHINGLE GUTTER ALUMINUM FASCIA DOWNSPOUT 12" VERTICAL WOOD OR CONCRETE SIDING 6" HORIZONTAL WOOD OR CONCRETE SIDING STONE VENEER COLUMN BASE STONE VENEER 12" VERTICAL WOOD OR CONCRETE SIDING PELLA WINDOWS W/ 5/4X4 TRIM; TYP. ALUMINUM FASCIA PELLA WINDOWS W/ 5/4X4 TRIM PELLA WINDOWS W/ 5/4X4 TRIM PELLA WINDOWS W/ 5/4X4 TRIM; TYP. COLUMN FAUX TIMBER BRACKET 5/4X6 FRIEZE BOARD; TYP. 5/4X4 CORNER TRIM; TYP. 5/4X6 FRIEZE BOARD;TYP. 5/4X4 CORNER TRIM; TYP. EXPOSED FOUNDATION DOUBLE FRIEZE BOARD (2) 5/4X6 6" HORIZONTAL WOOD OR CONCRETE SIDING FAUX TIMBER 5/4X4 CORNER TRIM 5/4X6 FRIEZE BOARD 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com DATE:DRAWN BY: CHK'D BY: REVISED: C: \ U s e r s \ m t a y l o r \ D o c u m e n t s \ 1 9 - 1 3 7 . 4 D u b u q u e C o o p e r a t i v e L i v i n g - D e t a c h e d _ I A - m t a y l o r . r v t 11 / 3 0 / 2 0 2 1 1 1 : 0 1 : 5 2 A M A200 19-137 ---- EX T E R I O R EL E V A T I O N S 11/30/2021 MT KC 1/8" = 1'-0"2 BACK 1/8" = 1'-0"3 LEFT 1/8" = 1'-0"4 RIGHT 1/8" = 1'-0"1 FRONT NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E MAIN LEVEL100'-0" PICKLEBALL PLT. HEIGHT113'-0 3/4" PICKLEBALL PLT HT 13'-0 3/4" HEEL 2'-5 1/8" DUCTSOX PER MECHANICAL DRAWINGS MAIN LEVEL100'-0" MAIN PLT. HT.110'-1 1/8" PICKLEBALL PLT. HEIGHT113'-0 3/4" PICKLEBALL 113 MEETING 105 OUTDOOR STORAGE 111 OPEN TO BEYOND A500 5 A500 6 FAUX TIMBER BRACKET MAIN LEVEL100'-0" MAIN PLT. HT.110'-1 1/8" PLT. HT 10'-1 1/8" HEEL 1'-7 1/4" A500 7 ATTIC SPACE 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com DATE:DRAWN BY: CHK'D BY: REVISED: C: \ U s e r s \ m t a y l o r \ D o c u m e n t s \ 1 9 - 1 3 7 . 4 D u b u q u e C o o p e r a t i v e L i v i n g - D e t a c h e d _ I A - m t a y l o r . r v t 11 / 3 0 / 2 0 2 1 1 1 : 0 1 : 5 4 A M A300 19-137 ---- BU I L D I N G S E C T I O N S 11/30/2021 MT KC 3/16" = 1'-0"2 BUILDING SECTION 3/16" = 1'-0"3 BUILDING SECTION 3/16" = 1'-0"1 BUILDING SECTION *TRUSS BY TRUSS MANUFACTURER, LAYOUT SHOWN IS FOR REPRESENTATION ONLY *TRUSS BY TRUSS MANUFACTURER, LAYOUT SHOWN IS FOR REPRESENTATION ONLY *TRUSS BY TRUSS MANUFACTURER, LAYOUT SHOWN IS FOR REPRESENTATION ONLY NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E MAIN LEVEL100'-0" MAIN PLT. HT.110'-1 1/8" PICKLEBALL PLT. HEIGHT113'-0 3/4" A500 4 A500 10 *TRUSS BY TRUSS MANUFACTURER, LAYOUT SHOWN IS FOR REPRESENTATION ONLY OPEN TO BEYOND FAUX TIMBER 2X6 RAKE LADDER COLUMN STONE VENEER BASE BEAD BOARD SOFFIT VENTED ALUMINUM SOFFIT EXTERIOR WALL BEYOND FIREPLACE LOUNGE 102 MAIN LEVEL100'-0" MAIN PLT. HT.110'-1 1/8" ASPHALT SHINGLES ON #15 ROOF FELT; SEE STRUCT. TRUSS BY MANUFACTURER BEAD BOARD SOFFIT APPLIED TO BOTTOM OF TRUSS STONE VENEER BASE COLUMN BEAD BOARD SOFFIT APPLIED TO BOOTOM OF TRUSS GUTTER ALUMINUM FASCIA 2X6 SUBFASCIA 2X4 LOOKOUT @ 24" O.C. VENTED ALUMINUM SOFFIT 12" VERTICAL WOOD OR CONCRETE SIDING 5/8" OSB SHEATHING *TRUSS BY TRUSS MANUFACTURER, LAYOUT SHOWN IS FOR REPRESENTATION ONLY 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com DATE:DRAWN BY: CHK'D BY: REVISED: C: \ U s e r s \ m t a y l o r \ D o c u m e n t s \ 1 9 - 1 3 7 . 4 D u b u q u e C o o p e r a t i v e L i v i n g - D e t a c h e d _ I A - m t a y l o r . r v t 11 / 3 0 / 2 0 2 1 1 1 : 0 1 : 5 5 A M A301 19-137 ---- BU I L D I N G S E C T I O N S 11/30/2021 MT KC 3/16" = 1'-0"2 BUILDING SECTION 1/4" = 1'-0"1 ENTRY SECTION NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E MAIN LEVEL100'-0" MAIN PLT. HT.110'-1 1/8" HEEL 4'-1 7/8" PLATE HEIGHT 10'-1 1/8" FOUNDATION WALL; SEE STRUCT. 2" RIGID INSULATION 24" VERTICALLY & HORIZONTALLY HIGH DENSITY INSULATION 6" SIDING (HORIZONTAL) CONTINUOUS WEATHER BARRIER 5/8" PLYWOOD SHEATHING 2X6 WOOD STUDS @ 16" O.C. R-20 BATT INSULATION 5/8" GYPSUM WALL PANELS CEILING LINE; 5/8" GYPSUM WALL PANELS R-40 BLOWN INSULATION 2X4 LOOKOUT @ 24" O.C. 5/4X6 FRIEZE BOARD WOOD DOUBLE PLATE TREATED WOOD BASE PLATE SLOPE GRADE AWAY FROM BUILDING 2X6 SUBFASCIA VENTED ALUMINUM SOFFIT ALUMINUM FASCIA GUTTER 2X8 BLOCKING 5'-7" MAIN LEVEL100'-0" MAIN PLT. HT.110'-1 1/8" PLATE HEIGHT 10'-1 1/8" FOUNDATION WALL; SEE STRUCT. 2" RIGID INSULATION 24" VERTICALLY & HORIZONTALLY HIGH DENSITY INSULATION 12" SIDING VERTICAL CONTINUOUS WEATHER BARRIER 5/8" PLYWOOD SHEATHING 2X6 WOOD STUDS @ 16" O.C. R-20 BATT INSULATION 5/8" GYPSUM WALL PANELS CEILING LINE; 5/8" GYPSUM WALL PANELS R-40 BLOWN INSULATION 2X4 LOOKOUT @ 24" O.C. 5/4X6 FRIEZE BOARD WOOD DOUBLE PLATE TREATED WOOD BASE PLATE SLOPE GRADE AWAY FROM BUILDING 2X6 RAKE LADDER ALUMINUM FASCIA VENTED ALUMINUM SOFFIT GABLE-END TRUSS 5/8" PLYWOOD SHEATHING CONTINUOUSWEATHER BARRIER 6" HORIZONTAL SIDING 1" WOOD TRIM; SEE ELEVATIONS TAPE WEATHER BARRIER AT ROOF 1'-0" 2X8 BLOCKING MAIN LEVEL100'-0" MAIN PLT. HT.110'-1 1/8" A501 1 5'-0 1/8" HEEL 2'-10 3/4" PLATE HEIGHT 10'-1 1/8" 2X4 LOOKOUUT @ 24" O.C. VENTED ALUMINUM SOFFIT 2X6 SUBFASCIA FASCIA 5/4X6 FRIEZE BOARD WOOD DOUBLE PLATE 5/8" GYPSUM WALL PANELS 5/8" OSB SHEATHING 2X6 WOOD STUDS @ 16" O.C. R-20 BATT INSULATION 5/8" OSB SHEATHING CONTINUOUS WEATHER BARRIER 6" SIDING (HORIZONTAL) TREATED WOOS BASE PLATE FOUNDATION WALL; SEE STRUCT. HIGH DENSITY INSULATION 2" RIGID INSULATION 24" VERTICALLY & HORIZONTALLY SLOPE GRADE AWAY FROM BUILDING 2X4 LOOKOUT @ 24" O.C. 2X6 SUBFASCIA FASCIA FAUX TIMBER BRACKET 2X6 WOOD STUDS @ 16" O.C. 5/8" OSB SHEATHING CONTINUOUS WEATHER BARRIER 6" SIDING (HORIZONTAL) ASPHALT SHINGLE ON 15MM UNDERLAYMENT ASPHALT SHINGLE 1'-6" 3'-6" 2X8 BLOCKING 5/4X6 FRIEZE BOARD 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com DATE:DRAWN BY: CHK'D BY: REVISED: C: \ U s e r s \ m t a y l o r \ D o c u m e n t s \ 1 9 - 1 3 7 . 4 D u b u q u e C o o p e r a t i v e L i v i n g - D e t a c h e d _ I A - m t a y l o r . r v t 11 / 3 0 / 2 0 2 1 1 1 : 0 1 : 5 7 A M A310 19-137 ---- WA L L S E C T I O N S 11/30/2021 MT KC 1/2" = 1'-0"1 WALL SECTION-E1A 1/2" = 1'-0"3 WALL SECTION-E3A 1/2" = 1'-0"2 WALL SECTION-E2A NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E MAIN LEVEL100'-0" MAIN PLT. HT.110'-1 1/8" PLATE HEIGHT 10'-1 1/8" FOUNDATION WALL; SEE STRUCT. 2" RIGID INSULATION 24" VERTICALLY & HORIZONTALLY HIGH DENSITY INSULATION 12" SIDING (VERTICAL) CONTINUOUS WEATHER BARRIER 5/8" DENS GLASS WALL PANELS 2X6 WOOD STUDS @ 16" O.C. R-20 BATT INSULATION 5/8" GYPSUM WALL PANELS CEILING LINE; 5/8" GYPSUM WALL PANELS R-40 BLOWN INSULATION GABLE-END ROOF TRUSS 5/4X6 FRIEZE BOARD WOOD DOUBLE PLATE TREATED WOOD BASE PLATE A500 3 1'-0" VENTED ALUMINUM SOFFIT 2X6 RAKE LADDER ASPHALT SHINGLE ON #15 ROOF FELT ON SHEATHING PER STRUCTURAL MAIN LEVEL100'-0" MAIN PLT. HT.110'-1 1/8" PLATE HEIGHT 10'-1 1/8" FOUNDATION WALL; SEE STRUCT. 2" RIGID INSULATION 24" VERTICALLY & HORIZONTALLY HIGH DENSITY INSULATION 12" SIDING (VERTICAL) CONTINUOUS WEATHER BARRIER 5/8" DENS GLASS WALL PANELS 2X6 WOOD STUDS @ 16" O.C. R-20 BATT INSULATION 6" CMU BLOCK; GROUT CORES SOLID 7/8" HAT CHANNEL 5/8" GYPSUM WALL PANELS R-40 BLOWN INSULATION GABLE-END ROOF TRUSS ASPHALT SHINGLE ON #15 ROOF FELT ON SHEATHING PER STRUCUTAL 2X6 RAKE LADDER 5/4X6 FRIEZE BOARD WOOD DOUBLE PLATE TREATED WOOD BASE PLATE CEILING LINE; 5/8" GYSPUM WALL PANELS (2) 3/4" PLYWOOD SHEATHING (2) 2X8 WOOD STUDS @ 12" O.C. 2X8 RIM BOARD BOND BEAM CONNECTOR STRONG TIE HETA 16 CONNECTOR STRONG TIE HGAM 10 MAIN LEVEL100'-0" MAIN PLT. HT.110'-1 1/8" HEEL 1'-7 1/4" PLATE HEIGHT 10'-1 1/8" FOUNDATION WALL; SEE STRUCT. 2" RIGID INSULATION 24" VERTICALLY & HORIZONTALLY HIGH DENSITY INSULATION 6" SIDING (HORIZONTAL) CONTINUOUS WEATHER BARRIER 5/8" DENS GLASS SHEATHING 5/8" OSB SHEATHING 2X6 WOOD STUDS @ 16" O.C. R-20 BATT INSULATION 5/8" OSB SHEATHING 5/8" GYPSUM WALL PANELS CEILING LINE; 5/8" GYPSUM WALL PANELS 5/4X6 FRIEZE BOARD WOOD DOUBLE PLATE TREATED WOOD BASE PLATE SLOPE GRADE AWAY FROM BUILDING R-40 BLOWN INSULATION 2X4 LOOKOUT VENTED ALUMINUM SOFFIT 2X6 SUBFASCIA ALUMINUM FASCIA GUTTER A500 2 2X8 BLOCKING 1'-6" ASPHALT SHINGLE ON #15 ROOF FELT ON SHEATHING PER STRUCTURAL MAIN LEVEL100'-0" MAIN PLT. HT.110'-1 1/8" PLATE HEIGHT 10'-1 1/8" GUTTER ALUMINUM FASCIA 2X6 SUBFASCIA 2X4 LOOKOUT @ 24" O.C. TRUSS BY MANUFACTURER VENTED ALUMINUM SOFFIT 2X6 RAKE LADDER ALUMINUM FASCIA VENTED ALUMINUM SOFFIT GABLE-END TRUSS 5/8" DENS GLASS WALL PANELS CONTINUOUSWEATHER BARRIER 6" HORIZONTAL SIDING 1" WOOD TRIM; SEE ELEVATIONS TAPE WEATHER BARRIER AT ROOF R-40 BLOWN INSULATION FOUNDATION WALL; SEE STRUCT. 2" RIGID INSULATION 24" VERTICALLY & HORIZONTALLY HIGH DENSITY INSULATION 5/8" GYPSUM WALL PANELS 2X6 WOOD STUDS @ 16" O.C. R-20 BATT INSULATION 5/8" DENS GLASS WALL PANELS CONTINUOUS WEATHER BARRIER 1 1/2" AIR SPACE DRAINAGE MAT STONE VENEER W/ WATER REPELLENT CEILING LINE; 5/8" GYPSUM WALL PANELS WOOD DOUBLE PLATE TREATED WOOD BASE PLATE ASPHALT SHINGLE ON #15 ROOF FELT ON 1/2" OSB SHEATHING 1'-0" 11'-6 3/8" 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com DATE:DRAWN BY: CHK'D BY: REVISED: C: \ U s e r s \ m t a y l o r \ D o c u m e n t s \ 1 9 - 1 3 7 . 4 D u b u q u e C o o p e r a t i v e L i v i n g - D e t a c h e d _ I A - m t a y l o r . r v t 11 / 3 0 / 2 0 2 1 1 1 : 0 1 : 5 8 A M A311 19-137 ---- WA L L S E C T I O N S 11/30/2021 MT KC 1/2" = 1'-0"3 WALL SECTION-E7A 1/2" = 1'-0"4 WALL SECTION-E8A 1/2" = 1'-0"2 WALL SECTION-E6A 1/2" = 1'-0"1 WALL SECTION-E4A NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E MAIN LEVEL100'-0" MAIN PLT. HT.110'-1 1/8" THICKEN SLAB @ FIREPLACE 2X4 WOOD STUDS @ 16" O.C. 1/2" OSB SHEATHING MORTAR STONE VENEER R-11 BATT INSULATION PROVIDE BLOCKING FOR MANTLE MANTLE WOOD HEADER FIREPLACE; INSTALL ACCORDING TO MANUFACTURER SPECIFICATIONS HEARTH SLAB WOOD DOUBLE PLATE CEILING LINE; 5/8" GYPSUM WALL PANELS STONE TO 6" ABOVE CEILING EXTEND WOOD STUDS & INSULATION TO UNDERSIDE OF ROOF R-40 BLOWN INSULATION PROVIDE BLOCKING & DATA FOR TV/ART MAIN LEVEL100'-0" MAIN PLT. HT.110'-1 1/8" THICKEN SLAB @ FIREPLACE TREATED WOOD BASE PLATE CEILING LINE; 5/8" GYPSUM WALL PANELS R-40 BLOWN INSULATION 2X6 RAKE LADDER R-40 BLOWN INSULATION WOOD DOUBLE PLATE 5/8" GYPSUM WALL PANELS 2X6 WOOD STUDS @ 16" O.C. BATT INSULATION 5/8" GYPSUM WALL PANELS VENTED ALUMINUM SOFFIT 5/4X6 FRIEZE BOARD WOOD DOUBLE PLATE MAIN LEVEL100'-0" MAIN PLT. HT.110'-1 1/8" CEILING LINE WOOD PLATE 5/8" GYPSUM WALL PANELS 2X6 WOOD STUDS @ 16" O.C. BATT INSULATION 5/8" GYPSUM WALL PANELS TREATED WOOD BASE PLATE R-40 BLOWN INSULATION MAIN LEVEL100'-0" MAIN PLT. HT.110'-1 1/8" 5/8" GYPSUM WALL PANELS 7/8" HAT CHANNEL 6" CMU BLOCK; GROUT CORES COLID 7/8" HAT CHANNEL 5/8" GYPSUM WALL PANELS THICKEN SLAB @ CMU WALL CEILING LINE; 5/8" GYSPUM WALL PANELS (2) 3/4" PLYWOOD SHEATHING (2) 2X8 WOOD STUDS @ 12" O.C. 2X8 RIM BOARD BOND BEAM CONNECTOR STRONG TIE HETA 16 CONNECTOR STRONG TIE HGAM 10 R-40 BLOWN INSULATION A501 2 MAIN LEVEL100'-0" MAIN PLT. HT.110'-1 1/8" PICKLEBALL PLT. HEIGHT113'-0 3/4"6" SIDING (HORIZONTAL) CONTINUOUS WEATHER BARRIER 5/8" OSB SHEATHING 2X8 LSL STUD @ 16" O.C. BALLOON FRAMED R-20 BATT INSULATION 5/8" OSB SHEATHING 5/8" GYPSUM WALL PANELS 2X8 LSL BEAM 2X8 LSL BEAM TREATED WOOD BASE PLATE WOOD DOUBLE PLATE CEILING LINE; 5/8" GYPSUM WALL PANELS R-40 BLOWN INSULATION GABLE END ROOF TRUSS 2X6 RAKE LADDER ASPHALT SHINGLE ON #15 ROOF FELT ON SHEATHING PER STRUCTURAL VARIES 8'-2 1/2" 8'-2 1/2" FOUNDATION WALL; SEE STRUCT. HIGH DENSITY INSULATION 2" RIGID INSULATION 24" VERTICALLY & HORIZONTALLY SLOPE GRADE AWAY FROM BUILDING 1'-0" 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com DATE:DRAWN BY: CHK'D BY: REVISED: C: \ U s e r s \ m t a y l o r \ D o c u m e n t s \ 1 9 - 1 3 7 . 4 D u b u q u e C o o p e r a t i v e L i v i n g - D e t a c h e d _ I A - m t a y l o r . r v t 11 / 3 0 / 2 0 2 1 1 1 : 0 1 : 5 9 A M A312 19-137 ---- WA L L S E C T I O N S 11/30/2021 MT KC 1/2" = 1'-0"4 WALL SECTION @ FIREPLACE 1/2" = 1'-0"5 WALL SECTION @ PICKLE BALL COURT 1/2" = 1'-0"2 WALL SECTION-P1A 1/2" = 1'-0"3 WALL SECTION-P3A 1/2" = 1'-0"1 WALL SECTION-E9A *FIRE TREAT WALL ACCORDING TO MANUFACTURERS REQUIREMENTS. NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E A400 8 RR 108 RR 107 A400 4 3 5 2 4 A311 3 A312 106.1 107.1 108.1 9 6 7 EQ-01 EQ-02 EQ-04 EQ-08 EQ-09 EQ-07 EQ-05 EQ-06 EQ-03 EQ-10 FD EQ-04 EQ-08 EQ-09 EQ-07 EQ-05 EQ-06 EQ-10 FD EQ-01 EQ-02 EQ-03 EQ-04 EQ-05 EQ-06 EQ-04 EQ-05 EQ-06 4'-0" 4'-0" EPOXY PAINT EQ-02 EQ-01 EQ-05 EQ-04 EQ-06 EQ-07 EQ-08 EQ-09 5'-0" CERAMIC TILE LIGHT FIXTURE BY OWNER CERAMIC TILE COUNTERTOP: CLASSIC MARBLE #251 CARRERA EBONY, POLISHED 4" APRON EQ-03 LIGHT FIXTURE BY OWNER EQ-04 EQ-05 EQ-06 EPOXY PAINT EQ-03 CERAMIC TILE 5'-0" EPOXY PAINT EQ-04 EQ-05 EQ-009 EQ-07 EQ-08 CERAMIC TILE 5'-0" 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS, DISCIPLINES AND SPECIFICATIONS. 2. USE DIMENSIONAL INFORMATION GIVEN. DO NOT SCALE DRAWINGS. 3. EXTERIOR DIMENSIONS ARE TYPICALLY INDICATED TO THE EXTERIOR FACE OF THE STRUCTURE/GRID LINE UNLESS OTHERWISE NOTED. 4. INTERIOR PARTITION DIMENSIONS ARE TYPICALLY INDICATED TO THE STUD FACE UNLESS OTHERWISE NOTED. 5. ALL SITE INFO, FIXTURES AND EQUIPMENT SHOWN ON THIS SHEET IS PROVIDED FOR COORDINATION PURPOSES ONLY. THE LAYOUT IS CONSIDERED CONCEPTUAL. REFER TO CIVIL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE SPRINKLER, LIFE-SAFETY, ETC. DOCUMENTS FOR SPECIFIC DESIGN INFORMATION. 6. PROVIDE ADEQUATE BLOCKING FOR ALL CABINETS, RESTROOM FIXTURES, AND EQUIPMENT. 7. FOR WALL TYPES NOT SEEN ON PLAN REFER TO WALL SECTIONS AND DETAILS. 8. REFER TO ENLARGED PLANS IF ITS AVAILABLE FOR ADDITIONAL EXTERIOR AND INTERIOR INFORMATION. 9. BUILDING STRUCTURAL ELEMENTS SUCH MAIN FRAMES AND COLUMNS ARE SHOWN FOR REFERENCE ONLY. SEE STRUCTURAL DRAWINGS FOR DETAILS FLOOR PLAN GENERAL NOTE: CERAMIC TILE LIGHT FIXTURE BY OWNER EPOXY PAINT EQ-06 EQ-05 EQ-04 EQ-03 CERAMIC TILE 5'-0" EPOXY PAINT EQ-05 EQ-04 EQ-06 EQ-07 EQ-09 EQ-08 EQ-04 EQ-05 CERAMIC TILE 5'-0" EPOXY PAINT EQ-07 EQ-09 EQ-04 EQ-05 EQ-06 EQ-01 EQ-02 COUNTERTOP: CLASSIC MARBLE #251 CARRERA EBONY, POLISHED 4" APRON CERAMIC TILE 5'-0" 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com DATE:DRAWN BY: CHK'D BY: REVISED: C: \ U s e r s \ m t a y l o r \ D o c u m e n t s \ 1 9 - 1 3 7 . 4 D u b u q u e C o o p e r a t i v e L i v i n g - D e t a c h e d _ I A - m t a y l o r . r v t 11 / 3 0 / 2 0 2 1 1 1 : 0 2 : 0 2 A M A400 19-137 ---- EN L A R G E D P L A N S , EL E V A T I O N , & SE C T I O N S 11/30/2021 MT KC 1/2" = 1'-0"1 MAIN LEVEL PLAN - RESTROOM 1/2" = 1'-0"4 RESTROOM 106-ELEVATION 1/2" = 1'-0"5 RESTROOM 106-ELEVATION 1/2" = 1'-0"2 RESTROOM 106-ELEVATION 1/2" = 1'-0"3 RESTROOM 106-ELEVATION EQUIPMENT SCHEDULE EQ-01 EQ-02 EQ-03 EQ-04 EQ-05 EQ-06 EQ-07 EQ-08 EQ-09 EQ-10 SINK MIRROR HAND DRYER TOILET TOILET PAPER DISPENSER TOILET PARTITION 18" GRAB BAR 36" GRAB BAR 42" GRAB BAR FLOOR DRAIN 1/2" = 1'-0"8 RESTROOM 107-ELEVATION 1/2" = 1'-0"7 RESTROOM 107-ELEVATION 1/2" = 1'-0"6 RESTROOM 107-ELEVATION 1/2" = 1'-0"9 RESTROOM 107-ELEVATION NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E REF. 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS, DISCIPLINES AND SPECIFICATIONS. 2. USE DIMENSIONAL INFORMATION GIVEN. DO NOT SCALE DRAWINGS. 3. EXTERIOR DIMENSIONS ARE TYPICALLY INDICATED TO THE EXTERIOR FACE OF THE STRUCTURE/GRID LINE UNLESS OTHERWISE NOTED. 4. INTERIOR PARTITION DIMENSIONS ARE TYPICALLY INDICATED TO THE STUD FACE UNLESS OTHERWISE NOTED. 5. ALL SITE INFO, FIXTURES AND EQUIPMENT SHOWN ON THIS SHEET IS PROVIDED FOR COORDINATION PURPOSES ONLY. THE LAYOUT IS CONSIDERED CONCEPTUAL. REFER TO CIVIL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE SPRINKLER, LIFE-SAFETY, ETC. DOCUMENTS FOR SPECIFIC DESIGN INFORMATION. 6. PROVIDE ADEQUATE BLOCKING FOR ALL CABINETS, RESTROOM FIXTURES, AND EQUIPMENT. 7. FOR WALL TYPES NOT SEEN ON PLAN REFER TO WALL SECTIONS AND DETAILS. 8. REFER TO ENLARGED PLANS IF ITS AVAILABLE FOR ADDITIONAL EXTERIOR AND INTERIOR INFORMATION. 9. BUILDING STRUCTURAL ELEMENTS SUCH MAIN FRAMES AND COLUMNS ARE SHOWN FOR REFERENCE ONLY. SEE STRUCTURAL DRAWINGS FOR DETAILS FLOOR PLAN GENERAL NOTE: 4'-6" 4'-3 7/8"9'-0"7'-4 5/8" 5 1/2" 7'-7" W3 E1A E1A P1A P1A P1A A401 5 4 3 4'-0" 4'-0" P1A P1A105.1 A4016 P1A P1A P1A 103.1 F3'-0"3'-0"3'-0"3'-0"F3'-3 3/4" 3'-6" 1'-8" 2'-10" CERAMIC TILE BY OWNER OVEN DISHWASHER COUNTERTOP: QUARTZ W/ VEINING CABINETS: 36" WAYPOINT PAINTED LINEN W/ SLAB DRAWER CABINETS: 36" WAYPOINT PAINTED LINEN COUNTERTOP: QUARTZ W/ VEINING 2'-8 1/2" 2'-10" SPACE LEFT OPEN FOR MICROWAVE OVEN; FINISH INTERIOR OF HOLE WITH WOOD STAINED TO MATCH CABINETS 3'-0"3'-0"3'-0" ADJUSTABLE SHELVING CABINETS: 36" WAYPOINT PAINTED LINEN W/ SLAB DRAWER LOCKED CABINET ADJUSTABLE SHELVING 2'-10" COUNTERTOP: PREMIUM LAMINATE COLOR BY OWNER F 3'-0"3'-0"3'-0"F TV BY OWNER PROVIDE BACKING DATA/ELECTRIC FOR TV CABINETS: 36" SMART COLOR BY OWNER ALCOHOL CABINET BY OWNER 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com DATE:DRAWN BY: CHK'D BY: REVISED: C: \ U s e r s \ m t a y l o r \ D o c u m e n t s \ 1 9 - 1 3 7 . 4 D u b u q u e C o o p e r a t i v e L i v i n g - D e t a c h e d _ I A - m t a y l o r . r v t 11 / 3 0 / 2 0 2 1 1 1 : 0 2 : 0 3 A M A401 19-137 ---- EN L A R G E D P L A N S , EL E V A T I O N , & SE C T I O N S 11/30/2021 MT KC 1/2" = 1'-0"1 MAIN LEVEL PLAN-KITCHEN 1/2" = 1'-0"2 MAIN LEVEL PLAN-OFFICE 1/2" = 1'-0"5 KITCHEN-CABINET ELEVATION 1/2" = 1'-0"4 KITCHEN-ISLAND ELEVATION 1/2" = 1'-0"6 OFFICE-CABINET ELEVATION 1/2" = 1'-0"3 KITCHEN-CABINET ELEVATION NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS, DISCIPLINES AND SPECIFICATIONS. 2. USE DIMENSIONAL INFORMATION GIVEN. DO NOT SCALE DRAWINGS. 3. EXTERIOR DIMENSIONS ARE TYPICALLY INDICATED TO THE EXTERIOR FACE OF THE STRUCTURE/GRID LINE UNLESS OTHERWISE NOTED. 4. INTERIOR PARTITION DIMENSIONS ARE TYPICALLY INDICATED TO THE STUD FACE UNLESS OTHERWISE NOTED. 5. ALL SITE INFO, FIXTURES AND EQUIPMENT SHOWN ON THIS SHEET IS PROVIDED FOR COORDINATION PURPOSES ONLY. THE LAYOUT IS CONSIDERED CONCEPTUAL. REFER TO CIVIL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE SPRINKLER, LIFE-SAFETY, ETC. DOCUMENTS FOR SPECIFIC DESIGN INFORMATION. 6. PROVIDE ADEQUATE BLOCKING FOR ALL CABINETS, RESTROOM FIXTURES, AND EQUIPMENT. 7. FOR WALL TYPES NOT SEEN ON PLAN REFER TO WALL SECTIONS AND DETAILS. 8. REFER TO ENLARGED PLANS IF ITS AVAILABLE FOR ADDITIONAL EXTERIOR AND INTERIOR INFORMATION. 9. BUILDING STRUCTURAL ELEMENTS SUCH MAIN FRAMES AND COLUMNS ARE SHOWN FOR REFERENCE ONLY. SEE STRUCTURAL DRAWINGS FOR DETAILS FLOOR PLAN GENERAL NOTE: MANTLE PROVIDE BLOCKING FOR MANLTE PROVIDE DATA & BLOCKING FOR TV/ART FIREPLACE; INSTALL PER MANUFACRUTER RECOMMENDATIONS STONE TO 6" ABOVE CEILING 1'-3" HEARTH SLAB STONE VENEER COUNTERTOP: QUARTZ COLOR BY OWNER CABINET: 36" SMART COLOR BY OWNER F 3'-0"3'-0"3'-0"F 2'-10" 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com DATE:DRAWN BY: CHK'D BY: REVISED: C: \ U s e r s \ m t a y l o r \ D o c u m e n t s \ 1 9 - 1 3 7 . 4 D u b u q u e C o o p e r a t i v e L i v i n g - D e t a c h e d _ I A - m t a y l o r . r v t 11 / 3 0 / 2 0 2 1 1 1 : 0 2 : 0 4 A M A402 19-137 ---- EN L A R G E D P L A N S , EL E V A T I O N , & SE C T I O N S 11/30/2021 MT KC 1/2" = 1'-0"5 FIREPLACE ELEVATION 1/2" = 1'-0"6 COFFEE BAR ELEVATION NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E MAIN PLT. HT.110'-1 1/8" PICKLEBALL PLT. HEIGHT113'-0 3/4" ROOF GABLE-END TRUSS APPLY GYPSUM PANELS TO FACE OF TRUSS CEILING LINE MAIN PLT. HT.110'-1 1/8" GUTTER STYLE "D" DRIP EDGE #15 ROOF FELT ASPHALT SHINGLES ALUMINUM FASCIA 2X6 SUBFASCIA 2X4 LOOKOUT @ 24" O.C. VENTED ALUMINUM SOFFIT 5/4X6 FRIEZE BOARD TAPE MEMBRANE AT DRIP EDGE WOOD DOUBLE PLATE 5/8" OSB SHEATHING R-20 BATT INSULATION 2X6 WOOD STUDS @ 16" O.C. 5/8" DENS GLASS WALL PANELS CONTINUOUS WEATHER BARRIER SIDING R-40 BLOWN INSULATION WOOD TRUSS BY MANUFACTURER 5/8" GYPSUM WALL PANELS 5/8" OSB SHEATHING 2X8 BLOCKING DRIP EDGE TAPE MEMBRANE AT DRIP EDGE #15 ROOF FELT ASPHALT SHINGLES ALUMINUM FASCIA 2X6 SUBFASCIA 2X6 RAKE LADDER VENTED ALUMINUM SOFFITGABLE END TRUSS EXTERIOR SHEATHING CONTONUOUS WEATHER BARRIER SIDING 5/4X6 FRIEZE BOARD 4 1/2" 6" CMU BLOCK 7/8" HAT CHANNEL 5/8" GYPSUM WALL PANELS STURCTURAL BOND BEAM TAPE & PAINT CORNER GYP. RETURN @ DOOR FRAME HOLLOW METAL FRAME DOOR PELLA WINDOW TAPE WEATHER BARRIER AT FLANGE VINYL SIDINGCONTINUOUS WEATHER BARRIER5/8" OSB SHEATHING 2X8 LSL STUD5/8" OSB SHEATHING5/8" GYPSUM WALL PANELS R-20 BATT INSULATION HEADER BY CONTRACTOR GYP RETURN @ WINDOW FRAME TAPE & PAINT CORNER 1X4 TRIM BOARD 1X8 TRIM BOARD PELLA WINDOW TAPE WEATHER BARRIER AT FLANGE VINYL SIDINGCONTINUOUS WEATHER BARRIER5/8" OSB SHEATHING 2X8 LSL STUD5/8" OSB SHEATHING5/8" GYPSUM WALL PANELS R-20 BATT INSULATION 1X4 TRIM BOARD 2X12 RAKE LADDER ALUMINUM FASCIA DRIP EDGE SELF ADHERED MEMBRANE LAYER ASPHALT SHINGLE VENTED ALUMINUM SOFFIT 6X12 TIMBER STAINED AND SEALED PRE DRILL HOLE HALFWAY THROUGH TIMBER 10" SCREW INFILL HOLE WITH WOOD STAINED AND SEALED TO MATCH GABLE END TRUSS5/8" PLYWOOD SHEATHING CONTINUOUS WEATHER BARRIER SIDING PICKLEBALL PLT. HEIGHT113'-0 3/4" GABLE END TRUSS5/8" PLYWOOD SHEATHINGCONTINUOUS WEATHER BARRIERSIDING BEAD BOARD SOFFIT WOOD TRIM STAINED AND SEALED TAPE WEATHER BARRIER OVER TRIM PELLA WINDOW TAPE WEATHER BARRIER AT FLANGE SIDINGCONTINUOUS WEATHER BARRIER5/8" OSB SHEATHING 2X6 WOOD STUD5/8" OSB SHEATHING5/8" GYPSUM WALL PANELS R-20 BATT INSULATION HEADER BY CONTRACTOR GYP RETURN @ WINDOW FRAME TAPE & PAINT CORNER 1X4 TRIM BOARD 1X6 TRIM BOARD PELLA WINDOW TAPE WEATHER BARRIER AT FLANGE SIDINGCONTINUOUS WEATHER BARRIER5/8" OSB SHEATHING 2X6 WOOD STUD5/8" OSB SHEATHING5/8" GYPSUM WALL PANELS R-20 BATT INSULATION 1X4 TRIM BOARD 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com DATE:DRAWN BY: CHK'D BY: REVISED: C: \ U s e r s \ m t a y l o r \ D o c u m e n t s \ 1 9 - 1 3 7 . 4 D u b u q u e C o o p e r a t i v e L i v i n g - D e t a c h e d _ I A - m t a y l o r . r v t 11 / 3 0 / 2 0 2 1 1 1 : 0 2 : 0 6 A M A500 19-137 ---- DE T A I L S 11/30/2021 MT KC 1 1/2" = 1'-0"1 DRAFT STOP-SECTION 3" = 1'-0"2 TYP. LOOKOUT DETAIL 3" = 1'-0"3 TYP. RAKE LADDER DETAIL 1 1/2" = 1'-0"7 DOOR JAMB @ SAFE ROOM 1 1/2" = 1'-0"5 WINDOW HEADER SECTION @ E9A 1 1/2" = 1'-0"6 WINDOW SILL SECTION @ E9A 1 1/2" = 1'-0"4 TIMBER LOOKOUT 1 1/2" = 1'-0"10 ENTRY SOFFIT DETAIL 1 1/2" = 1'-0"8 TYP. WINDOW HEADER SECTION 1 1/2" = 1'-0"9 TYP. WINDOWSILL SECTION NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E 3 1/2" 1'-8 5/8" 3 1/2"1'-2" 5 3/8" 3 1/2" ALUMINUM FASCIA GUTTER 2X6 SUBFASCIA 2X4 LOOKOUT @ 24" O.C. 1/2" PLYWOOD SHEATHING #15 ROOF FELT ASPHALT SHINGLE VENTED ALUMINUM SOFFIT 4X4 CEDAR TIMBER BRACKET 2X6 WOOD STUD @ 16" O.C. 5/8" OSB SHEATHING CONTINUOUS WEATHER BARRIER 6" SIDING (HORIZONTAL) STYLE "D" DRIP EDGE PRE DRILL HOLES HALFWAY THROUGH TIMBER; TYP. INFILL HOLE WITH WOOD STAINED AND SEALED TO MATCH; TYP. MAIN PLT. HT.110'-1 1/8" TRUSS BY MANUFACTURER R-40 BLOWN INSULATION 6X8X16 CMU BLOCK BOND BEAM 7/8" RC HAT CHANNEL 5/8" GYPSUM WALL PANELS CEILING LINE; 5/8" GYSPUM WALL PANELS (2) 3/4" PLYWOOD SHEATHING (2) 2X8 WOOD STUDS @ 12" O.C. CONNECTOR STRONG TIE HETA 16 CONNECTOR STRONG TIE HGAM 10 2X8 RIM BOARD (2) 2X8 WOOD STUDS 16" O.C. 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com DATE:DRAWN BY: CHK'D BY: REVISED: C: \ U s e r s \ m t a y l o r \ D o c u m e n t s \ 1 9 - 1 3 7 . 4 D u b u q u e C o o p e r a t i v e L i v i n g - D e t a c h e d _ I A - m t a y l o r . r v t 11 / 3 0 / 2 0 2 1 1 1 : 0 2 : 0 6 A M A501 19-137 ---- DE T A I L S 11/30/2021 MT KC 3" = 1'-0"1 TIMBER BRACKET DETAIL 3" = 1'-0"2 SAFE ROOM HEADER NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E 1.G.C. TO COORDINATE PLAN OPENING WIDTH DIMENSIONS W/ SCHEDULE. 2.SAFETY GLAZING SHOULD BE INSTALLED AT THE FOLLOWING LOCATIONS: INGRESS AND EGRESS DOORS •FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SWINGING DOORS. •FIXED OR OPERABLE PANELS ADJACENT TO A DOOR WHERE THE NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN A 24" ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" ABOVE THE WALKING SURFACE. •GLAZING IN AN INDIVIDUAL OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS NOTED ABOVE THAT MEETS ALL OF THE FOLLOWING CONDITIONS: A.EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQ. FT. B.EXPOSED TOP EDGE GREATER THAN 36" ABOVE THE FLOOR. C.ONE OR MORE WALKING SURFACES WITHIN 36" HORIZONTALLY OF THE PLANE OF THE GLASS. D.EXPOSED BOTTOM EDGE LESS THAN 18" ABOVE THE FLOOR •AS OTHERWISE SPECIFIED. 3.INSTALL FIRE RESISTANT GLASS AS REQUIRED FOR RATING AT ALL RATED DOOR/FRAME OPENINGS WITH GLASS. 4.NO WIRE GLASS ALLOWED ON PROJECT, PROVIDE TEMPERED OR LAMINATED GLASS AS REQ'D. FOR SAFETY GLASS, AND FIRE RATED GLASS AT FIRE RATED LOCATIONS. 5.ALL HOLLOW METAL DOORS, DOOR FRAMES, & WINDOW FRAMES TO BE PAINTED UNLESS NOTED OTHERWISE. 6.ALL DOORS ARE TO BE 1 3/4" THICK UNLESS OTHERWISE NOTED OR SCHEDULED. 7.DOOR/FRAME GLAZING IS TO BE 1/4" FLOAT GLASS UNLESS REQUIRED TO BE SAFETY GLASS AS STATED IN GENERAL NOTES. NOTES FOR OBSCURE GLASS & FIRE RATED CLEAR GLASS STILL APPLY. OPENINGS NOTED AS "SOUND REDUCTION ASSEMBLY" ARE TO HAVE LAMINATED GLASS EXCEPT AT RATED OPENINGS. EXTERIOR DOORS TO HAVE DOUBLE PANE INSULATING GLASS AS SPEC'D. 8.DOORS NEXT TO WALLS, NOT LOCATED BY DIMENSION ON PLANS OR DETAILS SHALL BE INSTALLED SUCH THAT THE DOOR, WHEN IN THE FULL OPEN POSITION AGAINST WALL STOP, IS PARALLEL TO ADJACENT WALL. COORDINATE WITH DOOR HARDWARE. 9.HM FRAMES TO BE PROVIDED FULL DEPTH OF WALL ASSEMBLY UNLESS NOTED OTHERWISE. DOOR AND FRAME GENERAL NOTES 1.ALL LOCKS SHALL BE REMOVABLE CYLINDER TYPE, MASTER KEYED.(CONTRACTOR TO COORDINATE KEYING WITH OWNER) 2. THUMB TURN LOCKS ARE NOT ALLOWED . DEADBOLTS ARE ONLY ALLOWED PER CODE. 3.PROVIDE HARDWARE FOR ALL DOORS AS NOTED. HARDWARE SHALL BE HEAVY DUTY COMMERCIAL GRADE 4.ALL EXTERIOR DOORS: (UNLESS OTHERWISE NOTED) -SHALL BE FULLY INSULATED, HEAVY-DUTY CONSTRUCTION. -FRAMES SHALL BE HEAVY-DUTY HOLLOW METAL CONSTRUCTION. -SHALL HAVE LEVER STYLE ADA DOOR HANDLES AND/OR PULLS. -SHALL HAVE LOCKING DEVICES. PANIC HARDWARE AT REQUIRED EXITS. 5.ALL INTERIOR DOORS: (UNLESS OTHERWISE NOTED) -SHALL BE SOLID-CORE, WOOD. -DOORS BETWEEN FULL HVAC AND REDUCED HVAC SPACES SHALL BE FULLY INSULATED. -FRAMES SHALL BE HEAVY DUTY HOLLOW METAL CONSTRUCTION. GLASS KEY VISION GLASS SPANDREL GLASS SAFETY GLAZING DOOR HARDWARE GENERAL NOTES S F FG SEE SCHED. SEE SCHED. SEE SCHED. SEE SCHED. 1'-0" 8" 6"6"FILL FILL S 2"SEE SCHED.2" 2" SEE SHCED. 2 1/2"SEE SCHED.2 1/2" 2 1/2" SEE SCHED. HM-001 AL-002 2"SEE SCHED.2" 4" SEE SHCED. HM-002 2"SEE SCHED. 2" 1'-0" 2" HM-003 2" SEE SCHED. 2" S PELLA WINDOWS WINDOW TRIM; TO MATCH SIDING SILL 6'-10 7/8" 2'-0" 4'-0" 6'-5" SILL 1'-9 1/2" 12'-0" 3'-0"3'-0"3'-0"3'-0" PELLA WINDOWS WINDOW TRIM; TO MATCH SIDINGSSSS PELLA WINDOWS WINDOW TRIM; TO MATCH SIDING6'-0" SILL 2'-2 5/8" 5'-2" S SS S SILL 1'-9 1/2" 6'-5" 7'-2" 1'-0 1/2" 3'-10"6"3'-4"6"3'-10" 12'-0" PELLA WINDOWS WINDOW TRIM; TO MATCH SIDING 2'-6" 5'-4 1/4" 6'-5" 1'-9 1/2" PELLA WINDOWS;SPANDREL GLASS WINDOW TRIM; TO MATCH SIDING 6'-8" 3'-4"3'-4" 16'-0 3/4" 3'-1 3/8" 1'-5 5/8" 2 1/2" 8'-0" 10'-0" 2 1/2"1'-7"2 1/2"6'-0"2 1/2"1'-7"2 1/2" S S SS 12'-9 1/2" DOOR & FRAME SCHEDULE DOOR NO.ROOM DOOR FRAME FIRE RATING REMARKS SIZE TYPE MTRL GLAZ TYPE MTRL GLAZ HDWRWD HT TK 100.1 VESTIBULE 6'-0" 8'-0" 1 3/4" FG1 : FG HM GLAZING AL-002 HM GLAZING 1 102.1 FIREPLACE LOUNGE 6'-0" 8'-0" 1 3/4" FG1 : FG HM GLAZING AL-002 HM GLAZING 1 103.1 OFFICE 3'-0" 7'-0" 1 3/4" FG WD GLAZING HM-001 HM GLAZING 2 105.1 MEETING 2'-6" 7'-0" 1 3/4" F WD --HM-001 HM --4 106.1 EXERCISE 3'-0" 7'-0" 1 3/4" FG WD GLAZING HM-001 HM --2 107.1 RR 3'-0" 7'-0" 1 3/4" F WD --HM-002 HM --3 108.1 RR 3'-0" 7'-0" 1 3/4" F WD --HM-002 HM --3 109.1 MECH 3'-0" 7'-0" 1 3/8" F WD --HM-001 HM --4 110.1 JAN.3'-0" 7'-0" 1 3/4" F WD --HM-001 HM --4 111.1 OUTDOOR STORAGE 6'-0" 7'-0" 1 3/4" F HM --HM-001 HM --2 112.2 HALLWAY 3'-0" 7'-0" 1 3/4" FG WD GLAZING HM-001 HM --1 112.3 HALLWAY 3'-0" 7'-0" 1 3/4" FG WD GLAZING HM-001 HM --1 113.1 PICKLEBALL 3'-0" 7'-0" 1 3/4" FG WD GLAZING HM-001 HM --2 113.2 PICKLEBALL 3'-0" 7'-0" 1 3/4" FG WD GLAZING HM-001 HM --1 114.1 STOR.6'-0" 7'-0" 1 3/8" F WD --HM-001 HM --4 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com DATE:DRAWN BY: CHK'D BY: REVISED: C: \ U s e r s \ m t a y l o r \ D o c u m e n t s \ 1 9 - 1 3 7 . 4 D u b u q u e C o o p e r a t i v e L i v i n g - D e t a c h e d _ I A - m t a y l o r . r v t 11 / 3 0 / 2 0 2 1 1 1 : 0 2 : 0 8 A M A600 19-137 ---- DO O R & F R A M E SC H E D U L E 11/30/2021 MT KC 1/4" = 1'-0"1 DOOR PANEL ELEVATIONS GLAZING GLAZING 1/4" = 1'-0"2 DOOR FRAME ELEVATIONS HARDWARE SET 1 • 2 PAIR HINGES • ENTRY LOCKSET • LEVER HANDLE/PANIC HARDWARE • CLOSER • SILENCER HARDWARE SET 2 • 2 PAIR HINGES • OFFICE LOCKSET • LEVER HANDLE BOTH SIDES • CLOSER • SILENCER HARDWARE SET 3 • 2 PAIR HINGES • PASSAGE LOCKSET • PUSH PANEL/PULL HANDLE • CLOSER • SILENCER HARDWARE SET 4 • 2 PAIR HINGES • OFFICE LOCKSET • LEVER HANDLE BOTH SIDES • CLOSER • SILENCER *ADDITIONAL WINDOW ENGINEERING REQUIRED BY MANUFACTURER *ADDITIONAL WINDOW ENGINEERING REQUIRED BY MANUFACTURER *ADDITIONAL WINDOW ENGINEERING REQUIRED BY MANUFACTURER *ADDITIONAL WINDOW ENGINEERING REQUIRED BY MANUFACTURER 1/4" = 1'-0"6 WINDOW-W4 1/4" = 1'-0"3 WINDOW-W1 1/4" = 1'-0"5 WINDOW-W3 1/4" = 1'-0"8 WINDOW-W6 1/4" = 1'-0"4 WINDOW-W2 1/4" = 1'-0"7 WINDOW-W5 HM-003 NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E REF. GAMES 104 FIREPLACE LOUNGE 102 MEETING 105 STOR. 114 OFFICE 103 EXERCISE 106 RR 107 RR 108 MECH 109 JAN. 110 OUTDOOR STORAGE 111 HALLWAY 112 PICKLEBALL 113 VESTIBULE 100 COFFEE LOUNGE 101 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com DATE:DRAWN BY: CHK'D BY: REVISED: C: \ U s e r s \ m t a y l o r \ D o c u m e n t s \ 1 9 - 1 3 7 . 4 D u b u q u e C o o p e r a t i v e L i v i n g - D e t a c h e d _ I A - m t a y l o r . r v t 11 / 3 0 / 2 0 2 1 1 1 : 0 2 : 0 9 A M A900 19-137 ---- FI N I S H F L O O R P L A N 11/30/2021 MT KC 1/8" = 1'-0"1 FINISH FLOOR PLAN ROOM FINISH SCHEDULE ROOM NO. ROOM NAME FLR BASE WALLS CEILINGS REMARKSNORTH EAST SOUTH WEST MTRL HEIGHT 100 VESTIBULE LVP-1 VB-1 PT-1 PT-1 PT-1 PT-1 GYP.10'-0 1/2" 101 COFFEE LOUNGE LVP-1 VB-1 PT-1 PT-1 PT-1 PT-1 GYP.10'-0 1/2" 102 FIREPLACE LOUNGE LVP-1 VB-1 PT-1 PT-1 PT-1 PT-1 GYP.10'-0 1/2" 103 OFFICE CPT-1 VB-1 PT-1 PT-1 PT-1 PT-1 GYP.10'-0 1/2" 104 GAMES LVP-1 VB-1 PT-1 PT-1 PT-1 PT-1 GYP.10'-0 1/2" 105 MEETING LVP-1 VB-1 PT-1 PT-1 CMT-2/PT-1 PT-1 GYP.10'-0 1/2" 106 EXERCISE RF-2 VB-1 PT-1 PT-1 PT-1 PT-1 GYP.10'-0 1/2" 107 RR CMT-1 CB-1 CMT-1/EPT-1 CMT-1/EPT-1 CMT-1 CMT-1/EPT-1 GYP.9'-1 7/8" 108 RR CMT-1 CB-1 CMT-1 CMT-1/EPT-1 CMT-1/EPT-1 CMT-1/EPT-1 GYP.9'-1 7/8" 109 MECH CONC-1 VB-1 EPT-1 EPT-1 EPT-1 EPT-1 GYP.10'-0 1/2" LEVEL 1 FINISH 110 JAN.CONC-1 VB-1 FRP-1/EPT-1 FRP-1/EPT-1 FRP-1/EPT-1 FRP-1/EPT-1 GYP.10'-0 1/2" LEVEL 1 FINISH/FRP UP TO 4'-0" 111 OUTDOOR STORAGE CONC-1 VB-1 EPT-1 EPT-1 EPT-1 EPT-1 GYP.10'-0 1/2" LEVEL 1 FINISH 112 HALLWAY CPT-1 VB-1 PT-1 PT-1 PT-1 PT-1 GYP.10'-0 1/2" 113 PICKLEBALL RF-1 VB-1 PT-1 PT-1 PT-1 PT-1 GYP.13'-0" 114 STOR.LVP-1 VB-1 PT-1 PT-1 PT-1 PT-1 GYP.10'-0 1/2" INTERIOR FINISH LEGEND KEY KEY DESCRIPTION DESCRIPTION MANUFACTURER PRODUCT/NUMBER COLOR/NAME REMARKS LVP-1 CPT-1 CMT-1 CMT-2 VLT-1 RF-1 PT-1 EPT-1 VB-1 CB-1 LUXURY VINYL PLANK CARPET TILE CERAMIC TILE CERAMIC TILE VINYL TILE MODUTILE ATHELTIC TILE FLOOR W/ LINING PAINT EPOXY PAINT VINYL BASE CERAMIC BASE TBD CPT-2 CARPET TILE TBDCORETECTBD TBDTBDTBD TBDTBDTBD TBDTBDTBD TBDTBDTBD TBDTBDTBD TBDTBDTBD TBDTBDTBD TBDTBDTBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBDTBD TBD RF-2 AMORIUM RUBBER FLOORING TBDTBDTBDTBD CONC-1 SEALED CONCRETE TBD TBD TBD TBD N FRP-1 FIBERGLASS REINFORCED PLASTIC TBDTBDTBDTBD NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E GP GENERAL PARAMETERS GP1 STRUCTURAL DRAWINGS ARE A PORTION OF THE CONTRACT DOCUMENTS AND ARE INTENDED TO BE USED WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE REQUIREMENTS FROM THESE DRAWINGS INTO THEIR SHOP DRAWINGS AND WORK. GP2 VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO FABRICATION OF ANY ITEMS. GP3 DRAWINGS SHALL BE COORDINATED WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL OPENINGS, ELECTRICAL COMPONENTS, FLOOR DEPRESSIONS, ETC. NOT SHOWN ON DRAWINGS. COORDINATE LOCATION, SIZE AND REINFORCEMENT OF ALL OPENINGS WITH RESPECTIVE TRADES BEFORE FABRICATION. REPORT ANY DISCREPANCIES AND/OR INTERFERENCE PROBLEMS TO THE ARCHITECT AND STRUCTURAL ENGINEER OF RECORD. GP4 THESE GENERAL NOTES SUPPLEMENT THE PROJECT SPECIFICATIONS. REFER TO THE PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. NOTES AND DETAILS ON THE STRUCTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER THE GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE PROVIDED, CONSTRUCTION SHALL BE AS SHOWN FOR SIMILAR WORK. GP5 THE BUILDING IS NOT STRUCTURALLY STABLE UNTIL ALL CONNECTIONS, FRAMING, SHEAR WALLS, X-BRACING, AND EXTERIOR WALLS ARE COMPLETE AND HAVE ACHIEVED FINAL DESIGN STRENGTH. CONTRACTOR IS SOLELY RESPONSIBLE FOR MAINTAINING STRUCTURAL STABILITY OVERALL AND TO ALL PORTIONS OF THE BUILDING DURING DEMOLITION, ERECTION AND CONSTRUCTION. TEMPORARY GRAVITY AND LATERAL FORCE BRACING SYSTEMS THAT MAY BE REQUIRED WILL BE DESIGNED BY, AND AT THE EXPENSE OF, THE CONTRACTOR. STRUCTURAL DRAWINGS DO NOT NECESSARILY INDICATE ANY OR ALL REQUIRED TEMPORARY SUPPORT SYSTEMS. TEMPORARY BRACING SYSTEMS ARE NOT TO BE REMOVED UNTIL STRUCTURAL WORK IS COMPLETE OR CONTRACTOR DEEMS THE AREA UNDER CONSIDERATION TO BE STABLE. GP6 CONTRACTOR'S CONSTRUCTION AND/OR ERECTION SEQUENCES SHALL RECOGNIZE AND CONSIDER THE EFFECTS OF THERMAL MOVEMENTS OF STRUCTURAL ELEMENTS DURING THE CONSTRUCTION PERIOD. GP7 RETAINING WALLS AND BASEMENT WALLS WHICH TIE TO UPPER SLABS SHALL NOT BE BACKFILLED UNTIL THE UPPER SLABS REACH FULL DESIGN STRENGTH, UNLESS ADEQUATE BRACING IS PROVIDED AT THE TOP OF THE WALL. GP8 AS USED IN GENERAL NOTES AND THROUGHOUT STRUCTURAL DRAWINGS, THE TERM "CONTRACTOR" IS DEFINED TO INCLUDE ANY OR ALL OF THE FOLLOWING: GENERAL CONTRACTOR AND THEIR SUBCONTRACTORS, CONSTRUCTION MANAGER AND THEIR SUBCONTRACTORS, FABRICATORS, INSTALLERS, DELEGATED DESIGNERS/ENGINEERS AND ERECTORS. SU SUBMITTALS SU1 GENERAL CONTRACTOR TO PROVIDE A SHOP DRAWING SUBMITTAL LOG ITEMIZING ALL PROPOSED SUBMITTALS FOR APPROVAL BY STRUCTURAL ENGINEER OF RECORD. SU2 ALL SHOP DRAWINGS SHALL BE CHECKED BY THE FABRICATOR AND APPROVED BY THE GENERAL CONTRACTOR PRIOR TO SUBMITTAL TO THE STRUCTURAL ENGINEER OF RECORD. SHOP DRAWING REVIEW BY ENGINEER IS LIMITED TO VERIFYING GENERAL CONFORMANCE TO THE CONTRACT DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR ANY CHANGES FROM THE CONTRACT DOCUMENTS, DIMENSIONAL ERRORS, COORDINATION ERRORS, OR OMISSIONS IN SHOP DRAWINGS. SU3 SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO FABRICATION AND CONSTRUCTION REGARDING ALL STRUCTURAL ITEMS, INCLUDING THE FOLLOWING: ● CONCRETE MIX DESIGNS (5 DAYS BEFORE POUR, MIN.) ● CONCRETE REINFORCEMENT ● PREMANUFACTURED WOOD ROOF TRUSS SYSTEMS SU4 SHOP DRAWINGS SHALL INCLUDE CONNECTIONS AS WELL AS SIZE, SPACING, AND GRADE OF ALL MEMBERS. PLANS AND ANY DETAILING NECESSARY FOR DETERMINING FIT AND PLACEMENT SHALL ALSO BE INCLUDED. SU5 IF SHOP DRAWINGS DIFFER FROM OR ADD TO THE DESIGN OF THE STRUCTURAL DRAWINGS, THEY SHALL BEAR THE SEAL AND SIGNATURE OF AN ENGINEER REGISTERED IN THE APPROPRIATE STATE. ANY CHANGES TO THE STRUCTURAL DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT AND ARE SUBJECT TO REVIEW AND APPROVAL OF THE STRUCTURAL ENGINEER OF RECORD. SU6 DESIGN DRAWINGS, SHOP DRAWINGS, AND CALCULATIONS FOR THE DESIGN AND FABRICATION OF ITEMS THAT ARE DESIGNED BY CONTRACTOR, INCLUDING: ● PREMANUFACTURED WOOD ROOF TRUSS SYSTEMS SHALL BEAR THE SEAL AND SIGNATURE OF AN ENGINEER REGISTERED IN THE APPROPRIATE STATE AND SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO FABRICATION AND CONSTRUCTION. CALCULATIONS SHALL BE INCLUDED FOR ALL CONNECTIONS TO THE STRUCTURE, CONSIDERING LOCALIZED EFFECTS ON STRUCTURAL ELEMENTS INDUCED BY THE CONNECTION LOADS. SU7 ITEMS THAT ARE DESIGNED BY CONTRACTOR SHALL BE DESIGNED TO RESIST THE LIVE LOADS INDICATED IN STRUCTURAL NOTES, DEAD LOAD, SELF WEIGHT, ANY ADDITIONAL LOADING INDICATED ON PLANS AND DETAILS, SNOW DRIFT, AND A NET WIND UPLIFT. SU8 ITEMS THAT ARE DESIGNED BY CONTRACTOR SHALL INCLUDE ANY RELEVANT TECHNICAL LITERATURE FROM MANUFACTURER. ALSO PROVIDE A CERTIFICATION FROM THE MANUFACTURER SHOWING THE PRODUCT IS IN COMPLIANCE WITH ALL APPLICABLE CODES AND STANDARDS. SU9 CONTRACTOR SHALL COORDINATE SEISMIC RESTRAINTS OF MECHANICAL, PLUMBING, AND ELECTRICAL EQUIPMENT, MACHINERY, AND ASSOCIATED PIPING WITH THE STRUCTURE. ANY CONNECTIONS TO STRUCTURE SHALL CONFORM TO ASCE 7, CHAPTER 13 AND SHALL BE DESIGNED BY AN ENGINEER REGISTERED IN THE APPROPRIATE STATE, AND SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO FABRICATION. SU10 FIELD ENGINEERED DETAILS DEVELOPED BY CONTRACTOR THAT DIFFER FROM OR ADD TO THE STRUCTURAL DRAWINGS SHALL BEAR THE SEAL AND SIGNATURE OF AN ENGINEER REGISTERED IN THE APPROPRIATE STATE AND SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO CONSTRUCTION. FP FOUNDATION PARAMETERS FP1 SIZE AND BOTTOM ELEVATIONS OF FOOTINGS HAVE BEEN ESTABLISHED BASED ON THE GEOTECHNICAL REPORT FILE NO. 1-4776 PREPARED BY TEAM SERVICES AND DATED 04/22/2020. AS EXCAVATION PROGRESSES, UNANTICIPATED SOIL CONDITIONS MAY REQUIRE CHANGES. CONTACT STRUCTURAL ENGINEER OF RECORD FOR EVALUATION OF THESE CHANGES. FP2 ALLOWABLE SOIL BEARING PRESSURE CONTINUOUS FOOTINGS.........................................1500 PSF SQUARE FOOTINGS.................................................1500 PSF FP3 MINIMUM FOOTING DEPTH FOR FROST PROTECTION (BELOW FINISHED GRADE)......................................42 IN. FP4 DESIGN EARTH PRESSURES: ACTIVE ..................................................................................... 35 PCF PASSIVE ...................................................................................260 PCF AT REST ...................................................................................60 PCF FP5 GEOTECHNICAL ENGINEER IS SOLE JUDGE OF THE SUITABILITY OF UNDERLYING MATERIAL TO SUPPORT FOUNDATIONS. BEARING MATERIAL SHALL BE APPROVED BY GEOTECHNICAL ENGINEER BEFORE FOUNDATION INSTALLATION. DO NOT PROCEED WITHOUT APPROVAL. FP6 PRIOR TO COMMENCING EARTHWORK, CONTRACTOR SHALL REVIEW AND BE FAMILIAR WITH ALL ASPECTS OF THE GEOTECHNICAL REPORT. CONTACT GEOTECHNICAL ENGINEER IF QUESTIONS OR DISCREPANCIES. COMMON NAIL SCHEDULE PENNYWEIGHT LENGTH (IN.) DIAMETER (IN.) 6d 2.00 0.113 8d 0.131 10d 0.148 16d 0.162 20d 0.192 2.50 3.00 3.50 4.00 8" o.c. WOOD FASTENER SCHEDULE NUMBER OR SPACING OF FASTENERS REQUIRED PER CONNECTION minimum nominal nail length (inches) x minimum nominal nail shank diameter (inches) Top or sole plate to stud / end nail Stud to top or sole plate / toe-nail Top plate laps and intersections / face nail each side of lap Sole plate to joist or blocking / face nail Sole plate to joist orblocking at braced wallpanel /face nail (numberper 16" joist space) Roof rafter to 2x ridge beam / toe-nail Roof rafter to 2x ridgebeam / face nail throughbeamintoend of rafter Ceiling joists laps over partitions / face nail Ceiling joist to parallel rafter / face nail Collar tie to rafter / face nail Jack rafter to hip / toe-nail Jack rafter to hip / face nail Roof rafter to plate / toe nail Corner studs / face nail Double studs / face nail Double top plate / face nail Diagonal bracing / face nail each stud N/AN/A12" o.c.12" o.c.8" o.c.16" o.c.16" o.c.16" o.c. 12" o.c. 16" o.c. 12" o.c. 12" o.c. 8" o.c. 8" o.c. 6" o.c. 8" o.c. 12" o.c.12" o.c. N/A N/A N/A N/A N/A - Fastener not applicable to connection 16" o.c. 12" o.c. 24" o.c. 2 3 3 4 N/A 4 4 8" o.c.8" o.c.6" o.c.8" o.c.8" o.c.8" o.c.16" o.c. 2 2 3 2 3 4 3 2 2 3 4 3 3 4 3 4 3 22 3 4 45 4 4 4 3 3 N/A 3 N/A 5 N/A N/A 5 N/A 4 N/A N/AN/A 2 3 3 3 3 4 4 N/A N/A N/AN/A44N/A3332 3 3 3 3 4 4 5 5 N/AN/A4433332 3 3 4 4 5 4 4 N/A N/A N/AN/A N/AN/A3344544 4464443 3 4 4 4 6 4 4 N/A N/A N/A65555543Ceiling joist to plate / toe-nail Built-up girders andbeams /face nail at topand bot. staggered eachside of each layer 24" o.c. (3 ea. end and splice) 24" o.c. (3 ea. end and splice) 24" o.c. (3 ea. end and splice) 24" o.c. (3 ea. end and splice) 16" o.c. (4 ea. end and splice) 16" o.c. (3 ea. end and splice) 16" o.c. (3 ea. end and splice) N/A N/A 3" o.c.6" o.c.4" o.c.6" o.c.6" o.c.6" o.c.6" o.c.6" o.c.Rim joist to top plate/toe-nail Bridging to joist/toe-nail each end N/A N/A N/A N/A 2 3 3 3 4 N/AN/A4434333 Blocking between joist or rafter to top plate / toe-nail Joist to sill or girder / toe-nail Ledger strip / face nail Joist to band joist / face nail N/AN/A4434333 3 4 4 4 6 4 4 N/A N/A N/AN/A66N/A5553 CONNECTION/LOCATION 3 1/2 x 0.162 3 x 0.148 3 1/4 x 0.131 3 x 0.131 2 1/2 x 0.131 3 1/4 x 0.120 3 x 0.120 2 3/8 x 0.113 2 x 0.113 8" o.c.8" o.c. 3 TYPICAL STRUCTURAL ABBREVIATIONS (PERIODS w/ ABBREVIATIONS MAY BE OMITTED WITHOUT CHANGING MEANING). & AND @ AT A.B. ANCHOR BOLT A.C.I. AMERICAN CONCRETE INSTITUTE A.E.S.S. ARCHITECTURALLY EXPOSED STRUCTURAL STEEL A.I.S.C. AMERICAN INSTITUTE OF STEEL CONSTRUCTION A.S.T.M. AMERICAN SOCIETY FOR TESTING AND MATERIALS ADD. ADDENDUM ADD'L. ADDITIONAL ALT. ALTERNATE ARCH. ARCHITECTURAL B.P. BASE PLATE B/ BOTTOM OF BLDG. BUILDING BRG. BEARING C.I.P. CAST IN PLACE C.J. CONSTRUCTION JOINT C.M.U. CONCRETE MASONRY UNIT C.P. COMPLETE PENETRATION CL CENTERLINE CLG. CEILING CLR. CLEAR CONC. CONCRETE CONN. CONNECTION CONST. CONSTRUCTION CONT. CONTINUOUS CONTR. CONTRACTOR D.B.A. DEFORMED BAR ANCHOR D.L. DEAD LOAD L ANGLE L.L LIVE LOAD L.L.H. LONG LEG HORIZONTAL L.L.V. LONG LEG VERTICAL L.P. LOW POINT LB. POUND L.S.H. LONG SIDE HORIZONTAL L.S.V. LONG SIDE VERTICAL LONG. LONGITUDINAL LT. GA. LIGHT GAGE M.E.P. MECHANICAL, ELECTRICAL, PLUMBING M.S.J.C. MASONRY STANDARDS JOINT COMMITTEE MAX. MAXIMUM MECH. MECHANICAL MFR. MANUFACTURER MIN. MINIMUM MISC. MISCELLANEOUS MTL. METAL N.D.S. NATIONAL DESIGN SPECIFICATION N.I.C. NOT IN CONTRACT N.S. NEAR SIDE N.T.S. NOT TO SCALE O.C. ON CENTER O.S.H.A. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION O.W.J. OPEN WEB JOIST OPNG. OPENING OPP. OPPOSITE P.C.I. PRECAST/PRESTRESSED CONCRETE INSTITUTE DET. DETAIL DIA. or Φ DIAMETER DIAG. DIAGONAL DIM. DIMENSION DN. DOWN DWGS. DRAWINGS E.F. EACH FACE E.J. EXPANSION JOINT E.W. EACH WAY EA. EACH EL. ELEVATION ELEC. ELECTRICAL EQ. EQUAL EXT. EXTERIOR F.S. FAR SIDE FIN. FINISH FM FOUNDATION MISCELLANEOUS FNDN. FOUNDATION FT FOOT/FEET GA. GAGE GALV. GALVANIZED GC. GENERAL CONTRACTOR H.P. HIGH POINT HORIZ. HORIZONTAL HT. HEIGHT I.B.C. INTERNATIONAL BUILDING CODE IN. INCH/INCHES INT. INTERIOR K or k KIP P.P. PARTIAL PENETRATION P.S.I. POUNDS PER SQUARE INCH P.S.F. POUNDS PER SQUARE FOOT P.C.F. POUNDS PER CUBIC FOOT PL PLATE PLBG. PLUMBING QTY. QUANTITY R or RAD. RADIUS REF. REFERENCE REINF. REINFORCING REQ'D. REQUIRED REV. REVISION RRE RAKER RHODES ENGINEERING S.D.I. STEEL DECK INSTITUTE S.J.I. STEEL JOIST INSTITUTE S.O.G. SLAB ON GRADE SCHED. SCHEDULE SIM. SIMILAR SPA. SPACING/SPACES SPECS. SPECIFICATIONS STD. STANDARD STRUC. STRUCTURAL T/ TOP OF TYP. TYPICAL U.N.O. UNLESS NOTED OTHERWISE VERT. VERTICAL V.I.F. VERIFY IN FIELD (FIELD VERIFY) w/ WITH w/o WITHOUT W.F. WIDE FLANGE W.P. WORKPOINT W.W.F. WELDED WIRE FABRIC VERIFICATION AND INSPECTION FREQUENCY / TASK 1. INSPECT REINFORCEMENT, INCLUDING PRESTRESSING TENDONS, & VERIFY PLACEMENT. 9. INSPECT FORMWORK FOR SHAPE, LOCATION & DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED. CONCRETE SOILS 1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY. 2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH & HAVE REACHED PROPER MATERIAL. 3. PERFORM CLASSIFICATION & TESTING OF COMPACTED FILL MATERIALS. 4. VERIFY USE OF PROPER MATERIALS, DENSITIES & LIFT THICKNESSES DURING PLACEMENT & COMPACTION OF COMPACTED FILL. 5. PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE & VERIFY THAT SITE HAS BEEN PREPARED PROPERLY. PROGRAM FOOTNOTES 1. THE ITEMS INDICATED ABOVE SHALL BE INSPECTED IN ACCORDANCE WITH CHAPTER 17 OF THE IBC BY A CERTIFIED SPECIAL INSPECTOR FROM AN ESTABLISHED TESTING AGENCY. FOR MATERIAL SAMPLING AND TESTING REQUIREMENTS, REFER TO THE PROJECT SPECIFICATIONS & THE SPECIFIC STRUCTURAL NOTES SECTIONS. THE TESTING AGENCY SHALL SEND COPIES OF ALL STRUCTURAL TESTING & INSPECTION REPORTS DIRECTLY TO THE ARCHITECT, STRUCTURAL ENGINEER, CONTRACTOR, & BUILDING OFFICIAL. ANY MATERIALS WHICH FAIL TO MEET THE PROJECT SPECIFICATIONS SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. SPECIAL INSPECTION TESTING REQUIREMENTS APPLY EQUALLY TO ALL BIDDER DESIGNED COMPONENTS. 2.CONT.-CONTINUOUS SPECIAL INSPECTION. SPECIAL INSPECTOR IS PRESENT WHEN & WHERE THE WORK TO BE INSPECTED IS BEING PERFORMED. (IBC SECTION 1702). 3.PERIODIC -PERIODIC SPECIAL INSPECTION. SPECIAL INSPECTOR IS INTERMITTENTLY PRESENT WHERE THE WORK TO BE INSPECTED HAS BEEN OR IS BEING PERFORMED. 4.OBSERVE -SPECIAL INSPECTOR SHALL OBSERVE THESE ITEMS ON A RANDOM BASIS. OPERATIONS NEED NOT BE DELAYED PENDING THESE INSPECTIONS (AISC 360 SECTION N5). 5.PERFORM -SPECIAL INSPECTOR SHALL PERFORM THESE TASKS FOR EACH JOINT, CONNECTION, ELEMENT OR MEMBER (AISC 360 SECTION N5). 6. SPECIAL INSPECTION IS NOT REQUIRED FOR WORK PERFORMED BY AN APPROVED FABRICATOR (IBC SECTION 1704.2.2). 7. ALL WELDS SHALL BE VISUALLY INSPECTED. 8. CJP WELDS SHALL BE TESTED ULTRASONICALLY OR BY SIMILAR APPROVED METHOD. 9. INSPECTION FOR PREFABRICATED CONSTRUCTION SHALL BE THE SAME AS IF THE MATERIAL USED IN THE CONSTRUCTION TOOK PLACE ON SITE. CONTINUOUS INSPECTION WILL NOT BE REQUIRED DURING PREFABRICATION IF THE APPROVED AGENCY CERTIFIES THE CONSTRUCTION AND FURNISHES EVIDENCE OF COMPLIANCE. 10. ALL ELEMENTS OF THE WOOD FRAMED LATERAL LOAD RESISTING SYSTEM SHALL BE VISUALLY INSPECTED. SP SPECIAL INSPECTION SP1 SPECIAL INSPECTION PROGRAM SHALL CONFORM TO CHAPTER 17 OF THE IBC. SP2 THE OWNER SHALL EMPLOY A SPECIAL INSPECTOR TO PERFORM THE REQUIRED TESTS AND SPECIAL INSPECTIONS WITH QUALIFICATIONS DESCRIBED PER IBC CHAPTER 17 AND THE PROJECT SPECIFICATIONS. SP3 SPECIAL INSPECTION REPORTS SHALL BE FURNISHED TO BUILDING OFFICIAL, OWNER, ARCHITECT, STRUCTURAL ENGINEER, AND CONTRACTOR. SP4 SPECIAL INSPECTOR SHALL SUBMIT A FINAL REPORT STATING THAT THE STRUCTURAL WORK WAS, TO THE BEST OF THE SPECIAL INSPECTOR'S KNOWLEDGE, PERFORMED IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS. SP5 SPECIAL INSPECTION PROGRAM: 2. INSPECT REINFORCING BAR WELDING: 3. INSPECT ANCHORS CAST IN CONCRETE. 5. VERIFY USE OF REQUIRED DESIGN MIX. 6. PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP & AIR CONTENT TESTS AND DETERMINE CONCRETE TEMPERATURE. 7. INSPECT CONCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES. 8. VERIFY MAINTENANCE OF SPECIFIED CURING TEMPERATURE & TECHNIQUES. PERIODIC PERIODIC PERIODIC PERIODIC PERIODIC CONT. CONT. PERIODIC PERIODIC PERIODIC PERIODIC CONT. A. VERIFY WELDABILITY OF REINFORCING BARS OTHER THAN ASTM A706. B. INSPECT SINGLE-PASS FILLET WELDS, MAXIMUM 5/16". C. INSPECT ALL OTHER WELDS. PERIODIC PERIODIC CONT. 4. INSPECT ANCHORS POST-INSTALLED IN HARDENED CONCRETE MEMBERS: A. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR UPWARDLY INCLINED ORIENTATIONS TO RESIST SUSTAINED TENSION LOADS. CONT. B. MECHANICAL ANCHORS AND ADHESIVE ANCHORS NOT DEFINED IN 4.A.PERIODIC CN CONCRETE NOTES CN1 CONCRETE WORK SHALL CONFORM TO CHAPTER 19 OF THE IBC. CN2 WHERE NEW CONCRETE IS PLACED AGAINST EXISTING CONCRETE, THE EXISTING CONCRETE SURFACE SHALL BE CLEANED AND ROUGHENED TO A MINIMUM OF 1/4" AMPLITUDE. CN3 ALL EXPOSED EDGES OF CONCRETE MEMBERS SHALL BE CHAMFERED 3/4" U.N.O. CN4 CONCRETE FORMWORK: CN4.1 SLEEVES, OPENINGS, CONDUIT, AND OTHER EMBEDDED ITEMS NOT SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE APPROVED BY THE STRUCTURAL ENGINEER PRIOR TO POURING CONCRETE. CONDUITS EMBEDDED IN SLABS SHALL NOT BE LARGER IN OUTSIDE DIMENSION THAN ONE THIRD OF THE THICKNESS OF THE SLAB AND SHALL NOT BE SPACED CLOSER THAN THREE DIAMETERS ON CENTER. CN4.2 VERIFY ALL BLOCK OUTS WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING REQUIREMENTS PRIOR TO POURING. CN5 CONCRETE REINFORCEMENT: CN5.1 DETAILING, FABRICATION, AND PLACEMENT OR REINFORCEMENT SHALL CONFORM TO ACI-315. CN5.2 ALL REINFORCEMENT TO BE ASTM A615 GRADE 60 U.N.O. WELDED WIRE FABRIC TO BE ASTM A185 WITH WIRE CONFORMING TO ASTM A82. REINFORCING STEEL SHALL BE SECURELY TIED IN PLACE USING #16 ANNEALED IRON WIRE. REINFORCEMENT SHALL BE CONTINUOUS THROUGH ALL CONSTRUCTION JOINTS, U.N.O. CN5.3 ALL CONTINUOUS REINFORCING SHALL BE SPLICED USING CLASS B TENSION SPLICES, U.N.O. CN5.4 BARS IN BEAMS AND SLABS SHALL BE SUPPORTED ON WELL-CURED CONCRETE BLOCKS OR APPROVED METAL CHAIRS, AS SPECIFIED BY THE CRSI MANUAL OF STANDARD PRACTICE, MSP-1. CN5.5 CONTINUE HORIZONTAL WALL BARS THROUGH PILASTERS, COLUMNS, INTERSECTING WALLS AND INTERSECTING FOUNDATIONS. REFER TO TYPICAL DETAILS FOR LAYOUT OF CORNER BARS AND BARS IN SMALL WALL SECTIONS. SLAB BARS SHALL BE HOOKED INTO WALLS OR HOOKED DOWELS SHALL BE PROVIDED TO MATCH SLAB REINFORCING. PROVIDE HOOKED DOWELS FROM FOOTINGS TO MATCH VERTICAL WALL REINFORCING. CN5.6 ADD TWO DIAGONAL #5 BARS, FOUR FEET LONG, CENTERED, AT EACH CORNER OF FOUNDATION OR SLAB OPENING, U.N.O. CN5.7 U.N.O., INSTALL WWF 1 1/2" FROM TOP OF ALL SLABS ON GRADE, TOPPING SLABS ON DECK, OR TOPPING SLABS ON PRECAST. LAP JOINTS TWO FULL MESHES BUT NOT LESS THAN 8". AT CONSTRUCTION JOINTS, LOCATE WWF AT MID DEPTH OF SLAB. CN6 COVERAGE FOR REINFORCEMENT: CN6.1 CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH ................. 3" CN6.2 CONCRETE EXPOSED TO EARTH AND WEATHER: #6 THRU #18 BARS ................................ 2" #5 BAR, W31 OR D31 WIRE AND SMALLER ....................................... 1 1/2" CN6.3 CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: SLABS, WALLS, JOISTS: #14 AND # 18 .......................................... 1 1/2" #11 BAR AND SMALLER ........................ 3/4" BEAMS, COLUMNS: PRIMARY REINFORCEMENT, TIES, STIRRUPS, SPIRALS ................... 1 1/2" CN7 CONCRETE COMPRESSIVE STRENGTHS SHALL BE VERIFIED BY STANDARD 28-DAY CYLINDER TESTS PER ASTM C39 AND SHALL BE AS FOLLOWS: FOOTINGS.............................................................. f'c = 3,000 PSI WALLS/PIERS/COLUMNS....................................... f'c = 4,000 PSI SLABS ON GRADE .................................................. f'c = 4,000 PSI CN8 SPECIAL INSPECTOR SHALL BE NOTIFIED IF ANY WATER IS TO BE ADDED IN FIELD. CN9 CONCRETE FOUNDATIONS: CN9.1 ALL FOUNDATION EXCAVATIONS MUST BE REVIEWED AND APPROVED BY THE SOILS ENGINEER PRIOR TO PLACEMENT OF CONCRETE. CN9.2 ACCURATELY SET AND SECURELY SUPPORT REINFORCING, DOWELS AND ANCHOR BOLTS PRIOR TO PLACEMENT OF CONCRETE. WET- STICKING OR FLOATING OF REINFORCING,DOWELS AND ANCHOR RODS IS NOT ALLOWED. CN9.3 PROVIDE CONSTRUCTION JOINTS, INSERTS, SLEEVES, DOWELS, ANCHORS, ETC., AS SHOWN. ITEMS SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS AND ACCORDING TO USUAL ACCEPTED STANDARDS OF THE TRADE. ANCHOR RODS PER ASTM F1554 AS SHOWN. CN9.4 ALL FOUNDATION COLD JOINTS SHALL BE KEYED. CONTINUOUS REINFORCING SHALL EXTEND ONE DEVELOPMENT LENGTH PLUS 6". LOCATE FOUNDATION COLD JOINTS AT EXPANSION JOINTS IN MASONRY VENEER WHEN POSSIBLE. CN9.5 REINFORCING SHOWN ON DETAILS IS THE REQUIRED MINIMUM. AT CONTRACTOR'S OPTION AND EXPENSE, ADDITIONAL REINFORCING MAY BE PERMITTED TO ASSIST IN EASE OF CONSTRUCTABILITY. ADDITIONAL REINFORCING MUST BE SUBMITTED FOR REVIEW ON SHOP DRAWINGS. CN10 PROVIDE MINIMUM 6000 PSI NON-SHRINK, NON-METALLIC GROUT UNDER COLUMN BASE PLATES. GROUT SHALL NOT CONTAIN GYPSUM. COLUMN BASES TO BE GROUTED BEFORE PLACEMENT OF CONCRETE TOPPING ON STEEL FORMS. CN11 MINIMUM 4" CONCRETE SLAB ON GRADE WITH WWF 6X6-W2.1 X W2.1, OVER VAPOR BARRIER, OVER A MINIMUM 6" COMPACTABLE, TRIMMABLE, GRANULAR FILL, TYP. U.N.O. ON DRAWINGS AND GEOTECHNICAL REPORT. CN12 SLAB CONTROL JOINTS: CN12.1 PROVIDE SLAB CONTROL JOINTS FOR THE FOLLOWING, U.N.O.: • SLAB-ON-GRADE ...........................................................10' ± 2' CN12.2 PROVIDE SLAB CONTROL JOINTS ON GRID LINE WHERE PRACTICAL. CN12.3 MAINTAIN A SLAB CONTROL JOINT ASPECT RATIO OF APPROXIMATELY 1:1. CN13 PROVIDE VERTICAL WALL JOINTS AS FOLLOWS, U.N.O.: CN13.1 WALLS TALLER THAN 12'..................................................H (H = WALL HEIGHT) CN13.2 WALLS 8' - 12'......................................................................2*H CN13.3 WALLS SHORTER THAN 8'................................................3*H CN13.4 PROVIDE WALL JOINT WITHIN 10' OF ALL CORNERS AND IN LINE WITH EDGES OF ALL WALL OPENINGS. CN13.5 MAXIMUM WALL JOINT SPACING SHALL NOT EXCEED 25 FEET. CN14 CONCRETE ACCESSORIES: CN14.1 U.N.O., EXPANSION BOLTS TO BE HILTI KWIK BOLT TZ OR APPROVED EQUIVALENT WITH EQUAL ICC TENSION AND SHEAR VALUES. EXPANSION ANCHORS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. DO NOT CUT REINFORCING IN NEW OR EXISTING CONCRETE DURING INSTALLATION. CN14.2 U.N.O., EPOXY ANCHORS TO BE HILTI HIT-RE 500 V3 OR APPROVED EQUIVALENT WITH EQUAL ICC TENSION AND SHEAR VALUES. EPOXY ANCHORS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. DO NOT CUT REINFORCING IN NEW OR EXISTING CONCRETE DURING INSTALLATION. CN15 PERMANENTLY EXPOSED EMBEDDED PLATES AND ANGLES TO BE HOT-DIP GALVANIZED AFTER FABRICATION, U.N.O. NO LOADS OR WELDS SHALL BE PLACED ON EMBEDDED PLATES OR ANGLES FOR A MINIMUM OF 7 DAYS AFTER CASTING. CN16 U.N.O. IN ARCHITECTURAL DRAWINGS, 2" RIGID EXTRUDED POLYSTYRENE PERIMETER INSULATION OR EQUAL TO BE INSTALLED ON INSIDE FACE OF FOUNDATION WALL/GRADE BEAM, EXTENDING DOWN FROM THE TOP OF FOUNDATION 42 INCHES, AND EXTENDING IN FROM THE EDGE OF FOUNDATION 24 INCHES BELOW SLAB. CN17 EPOXY REPAIR ADHESIVE SHALL CONFORM TO ASTM C881 AND SHALL BE A TWO- COMPONENT, LIQUID EPOXY WITH NON-SAG CONSISTENCY AND A LONG POT LIFE. THE EPOXY ADHESIVE SHALL BE SUITABLE FOR USE IN DRY OR DAMP CONDITIONS. MINIMUM SHEAR STRENGTH SHALL BE 5,000 PSI; MINIMUM TENSILE STRENGTH SHALL BE 4,000 PSI. HOLE SIZES AND INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH THE APPROVED ICC REQUIREMENTS. DO NOT CUT REINFORCING IN NEW OR EXISTING CONCRETE DURING PLACEMENT. CN18 COLD WEATHER PROTECTION CN18.1 DURING COLD WEATHER CONSTRUCTION, CONTRACTOR IS RESPONSIBLE FOR PROTECTING CURING CONCRETE PER THE RQMTS. OF ACI 306. CN18.2 DURING COLD WEATHER CONSTRUCTION, CONTRACTOR IS RESPONSIBLE FOR PROTECTING FOUNDATIONS THAT DO NOT EXTEND TO FROST DEPTH FROM HEAVING. AT CONTRACTOR'S OPTION, BOTTOM OF FOOTINGS MAY BE EXTENDED BEYOND THE FROST ZONE, IN LIEU OF SURFACE PROTECTION METHODS. NO ADD'L REINFORCING WILL BE REQ'D AT EXTENDED FOUNDATIONS. ALL MITIGATION WORK SHALL BE PART OF THE CONTRACTOR BID AND NOT COMPENSIBLE BY CHANGE ORDER. CN18.3 CONTRACTOR TO PROVIDE A FROST STOOP PER TYP. STOOP DETAIL @ ALL EXTERIOR DOORS, SEE ARCH. FOR DOOR LOCATIONS. WF WOOD FRAMING NOTES WF1 WOOD FRAMING WORK SHALL COMPLY WITH CHAPTER 23 OF THE IBC. WF2 THE QUALITY OF WOOD PRODUCTS AND FASTENERS, AND THE DESIGN OF OAD-SUPPORTING MEMBERS AND CONNECTIONS, SHALL CONFORM TO THE TANDARDS SPECIFIED IN THE AWC NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION AND ITS SUPPLEMENT DESIGN VALUES FOR WOOD CONSTRUCTION. WF3 COORDINATE WOOD NAILERS AND BLOCKING LOCATIONS WITH NEED AND REQUIREMENTS OF OTHER WORK INVOLVED. WF4 PROVIDE SOLID BLOCKING BETWEEN SAWN JOISTS AT ALL SUPPORTS AND AT MIDSPAN OF JOISTS EXCEEDING 8 FEET (8FEET ON-CENTER MAXIMUM SPACING FOR BLOCKING). WF5 GIRDER TRUSSES SHALL BEAR DIRECTLY OVER WALL STUDS. NUMBER OF STUDS SHALL MATCH THE NUMBER OF PLIES IN THE GIRDER TRUSS (MINIMUM OF TWO STUDS), U.N.O. WF6 CUTTING AND NOTCHING OF JOISTS AND STUDS SHALL CONFORM TO IBC SECTIONS 2308.5.9. WF7 SALVAGED LUMBER SHALL BE GRADED BY AN APPROVED GRADING AGENCY PRIOR TO USE AND SHALL MEET THE MINIMUM STRESSES SHOWN BELOW. WF8 WOOD FRAMING MATERIALS (MINIMUM DESIGN VALUES): WF8.1 SAWN LUMBER: WF8.1a LOAD-BEARING WALL STUDS DOUGLAS FIR-LARCH NO. 2 Fb = 900 PSI Ft = 575 PSI Fv = 180 PSI Fcp = 625 PSI F/c = 1,350 PSI E = 1,600,000 PSI WF8.1b FRAMING MEMBERS (BEAMS, JOISTS, ETC.) DOUGLAS FIR-LARCH NO. 2 Fb = 900 PSI Ft = 575 PSI Fv = 180 PSI Fcp = 625 PSI Fc = 1,350 PSI E = 1,600,000 PSI WF8.2 LAMINATED VENEER LUMBER (LVL): GRADE 1.9E Fb = 2,600 PSI Ft = 1,555 PSI Fv = 285 PSI Fcp = 750 PSI Fc = 2,510 PSI E = 1,900,000 PSI WF9 WOOD STRUCTURAL PANELS WF9.1 WOOD STRUCTURAL PANELS SHALL CONFORM TO THE REQUIREMENTS OF U.S. PRODUCT STANDARD PS1 FOR CONSTRUCTION AND INDUSTRIAL PLYWOOD, U.S. PRODUCT STANDARD PS2 PERFORMANCE STANDARD FOR WOOD-BASED STRUCTURAL-USE PANELS, OR APA PRP-108 PERFORMANCE STANDARDS. WF9.2 WOOD STRUCTURAL PANEL INSTALLATION SHALL BE IN CONFORMANCE WITH APA RECOMMENDATIONS. ALLOW 1/8" SPACING AT PANEL ENDS AND EDGES, UNLESS OTHERWISE RECOMMENDED BY THE PANEL MANUFACTURER. WF9.3 SHEAR WALL SHEATHING SHALL BE PLYWOOD OR OSB CONFORMING TO THE REQUIREMENTS FOR ITS TYPE SPECIFIED IN DOC PS1 OR PS2. SHEATHING SHALL BE APPLIED EITHER HORIZONTALLY OR VERTICALLY. SHEET SIZES SHALL BE 48"x96" UNLESS AT BOUNDARIES OR FRAMING CHANGES. WF9.4 WALL SHEATHING (SEE SHEAR WALL SCHEDULE): 5/8" CDX, APA RATED SHEATHING, 40/20 EXP. I OR 5/8" OSB, APA RATED SHEATHING, 40/20, EXP. I WF9.5 ROOF SHEATHING (SEE DIAPHRAGM SCHEDULE): 5/8" OSB OR CDX, APA RATED SHEATHING, 40/20, EXP. I WF9.6 WOOD STRUCTURAL PANELS USED AS SUBFLOOR, ROOF, OR WALL SHEATHING SHALL BE FASTENED TO FRAMING MEMBERS AS FOLLOWS, U.N.O.: 10d COMMON NAILS SPACED AT 6" O.C. AT PANEL EDGES, 12" O.C. AT INTERMEDIATE SUPPORTS. -OR- 2 7/8" X .12" NAILS SPACED AT 4" O.C. AT PANEL EDGES, 8" O.C. AT INTERMEDIATE SUPPORTS. -OR- 2 3/4" 14 GAGE STAPLES SPACED AT 4" O.C. AT PANEL EDGES, 8" O.C. AT INTERMEDIATE SUPPORTS. WF9.7 ALL SHEAR WALL PANEL SHEATHING EDGES SHALL BE BLOCKED. EDGE NAILS SHALL BE AT LEAST 3/8" FROM EDGES AND PANEL ENDS. STAGGER NAILING ON EDGES. WF9.8 ALL ROOF SHEATHING SHALL BE INSTALLED WITH FACE GRAIN PERPENDICULAR TO SUPPORTS, U.N.O. ROOF SHEATHING SHALL EITHER BE BLOCKED, TONGUE-AND-GROOVE, OR HAVE EDGES SUPPORTED BY PLYCLIPS. WHEN ROOF SHEATHING IS NAILED DIRECTLY TO BLOCKING, THE BLOCKING SHALL BE NAILED TO SUPPORT MEMBERS WITH A MINIMUM OF 16d NAILS AT 4" O.C. WF9.9 NAIL HEADS SHALL BE DRIVEN FLUSH WITH SHEATHING. DO NOT PENETRATE SURFACE PLY WITH NAIL HEADS. IF NAIL HEADS ARE NOT FLUSH, NOTIFY STRUCTURAL ENGINEER OF RECORD. WF10 NAILS AND STAPLES SHALL CONFORM TO THE REQUIREMENTS OF ASTM F1667. FASTENER TYPES AND SPACINGS SHALL BE AS INDICATED IN IBC TABLE 2304.10.1 OR ESR-1539, U.N.O. WF11 ALL FRAMING NAILS SHALL BE OF THE SIZE AND NUMBER INDICATED IN THE DRAWINGS AND CONFORM TO ASTM F1667 AND ESR-1539. NAILS SHALL BE IDENTIFIED BY LABELS (ATTACHED TO THEIR CONTAINERS) THAT SHOW THE MANUFACTURER'S NAME, NES REPORT NUMBER, NAIL SHANK DIAMETER, AND LENGTH. THIS INFORMATION ALSO SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER OF RECORD PRIOR TO FRAMING. NAILING NOT SHOWN SHALL BE AS INDICATED IN IBC TABLE 2304.10.1 OR ESR-1539. NAILS USED FOR FRAMING AND SHEATHING CONNECTIONS SHALL HAVE MIN. DIMENSIONS INDICATED IN THE TABLE BELOW: WF12 BOLTS AND LAG SCREWS SHALL CONFORM TO ANSI/ASME STANDARD B18.2.1. BOLT HOLES SHALL BE A MINIMUM OF 1/32" AND NO MORE THAN 1/16" LARGER THAN THE BOLT DIAMETER. ALL BOLTS AND LAG SCREWS SHALL BE INSTALLED WITH STANDARD CUT WASHERS. ALL A307 BOLTS SHALL HAVE CUT THREADS. WF13 METAL FRAMING CONNECTORS SHALL BE MANUFACTURED BY SIMPSON STRONG-TIE CO. ALL SPECIFIED FASTENERS MUST BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. BEFORE SUBSTITUTING ANOTHER BRAND, CONFIRM LOAD CAPACITY BASED ON RELIABLE PUBLISHED TESTING DATA OR CALCULATIONS. THE ENGINEER OF RECORD SHALL EVALUATE AND GIVE WRITTEN APPROVAL FOR SUBSTITUTION PRIOR TO INSTALLATION. HANGERS NOT SHOWN SHALL BE SIMPSON U-TYPE OR B-TYPE OF SIZE RECOMMENDED FOR THE MEMBER. WF14 ALL INTERIOR METAL FRAMING CONNECTORS SHALL RECEIVE G90 ZINC COATING, UNO. ALL METAL FRAMING CONNECTORS AND FASTENERS INSTALLED IN EXTERIOR CONDITIONS SHALL RECEIVE G185 (SIMPSON ZMAX) COATING OR APPROVED EQUIVALENT. ALL METAL FRAMING CONNECTORS AND FASTENERS SHALL BE COMPATIBLE WITH THE APPLIED WOOD TREATMENT. WT WOOD TRUSS FRAMING NOTES WT1 WOOD FRAMING WORK SHALL COMPLY WITH CHAPTER 23 OF THE IBC. WT2 DESIGN OF PREMANUFACTURED WOOD ROOF TRUSSES BY CONTRACTOR. DESIGN SHALL CONFORM TO THE PROFILES SHOWN ON PLANS AND SECTIONS, THE REQUIREMENTS OF IBC SECTION 2303.4, AND THE RECOMMENDATIONS OF THE TRUSS PLATE INSTITUTE. WT3 TRUSS MANUFACTURER IS RESPONSIBLE FOR DESIGNING OF TRUSSES TO ACCOMMODATE ALL LONG TERM DEFLECTION (CREEP) IN TRUSSES. WT4 IN ADDITION TO SELF WEIGHT, LIVE AND LATERAL LOADS INDICATED IN STRUCTURAL NOTES, DEAD LOAD, ANY ADDITIONAL LOADING INDICATED ON PLANS AND DETAILS, SNOW DRIFT, AND A MAXIMUM NET UPLIFT INDICATED IN STRUCTURAL NOTES, TRUSSES SHALL BE DESIGNED TO RESIST THE FOLLOWING MINIMUM LOADS: WT4.1 ROOF TRUSS LOADS: TOP CHORD DEAD LOAD 10 PSF BOTTOM CHORD DEAD LOAD 10 PSF TOP CHORD LIVE LOAD 25 PSF + DRIFT BOTTOM CHORD LIVE LOAD 0 PSF WT5 STORE MATERIALS ABOVE GROUND ON LEVEL WOOD BLOCKING, COVER FROM RAIN, ALLOWING WATER TO DRAIN FROM ALL PARTS. WT6 TRUSS MANUFACTURER SHALL PROVIDE INSTRUCTIONS TO FIELD CONSTRUCTION PERSONNEL INDICATING PROPER ERECTION PROCEDURES OF TRUSSES AND INSTALLATION OF CONNECTIONS AND ANY BRIDGING AND BRACING. WT7 CONSTRUCTION (TEMPORARY) TRUSS BRACING SHALL BE DETERMINED, FURNISHED, AND INSTALLED BY CONTRACTOR. CONSTRUCTION BRACING SHALL CONFORM TO THE REQUIREMENTS OF BCSI 1-03. WT8 PERMANENT LATERAL TRUSS BRACING REQUIRED FOR THE STRENGTH AND STABILITY OF TRUSS MEMBERS SHALL BE SPECIFIED BY TRUSS MANUFACTURER. WT9 ALL GIRDER TRUSSES THAT REQUIRE LAMINATING TWO OR MORE PLYS, MUST BE LAMINATED ACCORDING TO THE INSTRUCTIONS ON THE TRUSS DESIGN DRAWINGS BY THE TRUSS MANUFACTURER. WT10 CUTTING, DRILLING, OR ANY PROCEDURE THAT MAY DAMAGE THE TRUSS CHORDS OR WEBS IS NOT ALLOWED. REMOVAL OF TRUSS WEBS, EVEN TEMPORARILY, IS NOT ALLOWED. WT11 OVERLOADING A SINGLE OR GROUP OF TRUSSES WITH TOOLS, PLYWOOD, ROOFING, OR OTHER CONSTRUCTION MATERIALS IN NOT ALLOWED. ERECTING DAMAGED TRUSSES IS NOT ALLOWED. WT12 MAKING A FIELD REPAIR TO A DAMAGED TRUSS IS NOT ALLOWED WITHOUT APPROVAL FROM THE STRUCTURAL ENGINEER OF RECORD. WT13 U.N.O., CONTRACTOR TO PROVIDE FLOATING GYPSUM CORNER DETAILING AND FASTENING, PER THE GYPSUM ASSOCIATION'S SPECIFICATION FOR THE APPLICATION AND FINISHING OF GYPSUM PANEL PRODUCTS, GA-216. DP DESIGN PARAMETERS DP1 THE STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE ICC INTERNATIONAL BUILDING CODE, 2018 EDITION. DP2 UNIFORM LIVE LOADS: TYPICAL ROOF (GOVERNED BY SNOW)25 PSF+DRIFT DRIFT LOAD AS SHOWN ON PLAN DP3 SNOW DESIGN PARAMETERS: GROUND SNOW LOAD (Pg)30 PSF FLAT ROOF SNOW LOAD (Pf)25 PSF SNOW EXPOSURE FACTOR (C/E)1.0 SNOW LOAD IMPORTANCE FACTOR (Is)1.0 SNOW LOAD THERMAL FACTOR (Ct)1.0 DP5 EARTHQUAKE DESIGN PARAMETERS: SEISMIC IMPORTANCE FACTOR (Ie)1.0 Ss 0.07g S1 0.04g SEISMIC SITE CLASS D Sds 0.075g Sd1 0.064g SHORT-PERIOD SITE COEFFICIENT (Fa)1.6 LONG-PERIOD SITE COEFFICIENT (Fv)2.4 SEISMIC DESIGN CATEGORY A SEISMIC-FORCE-RESISTING SYSTEM: LIGHT-FRAMED WALLS SHEATHED WITH WOOD STRUCTURAL PANELS RATED FOR SHEAR SEISMIC BASE SHEAR (V) N-S 5 k SEISMIC BASE SHEAR (V) E-W 5 k SEISMIC RESPONSE COEFFICIENT (Cs) N-S 0.01 SEISMIC RESPONSE COEFFICIENT (Cs) E-W 0.01 RESPONSE MODIFICATION FACTOR (R) N-S N/A RESPONSE MODIFICATION FACTOR (R) E-W N/A REDUNDANCY FACTOR (ρ) N-S 1.0 REDUNDANCY FACTOR (ρ) E-W 1.0 SEISMIC ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE ANALYSIS DP6 WIND DESIGN PARAMETERS: BASIC WIND SPEED (V) (3 SECOND GUST)110 MPH RISK CATEGORY II WIND EXPOSURE CATEGORY C INTERNAL PRESSURE COEFFICIENT +/-.18 BASIC DESIGN PRESSURE @ ROOF 15 PSF (SERVICE) NET WIND UPLIFT @ ROOF 10 PSF (SERVICE) DP7 ROOF RAIN LOAD PARAMETERS: RAIN INTENSITY (i) 3.4 IN. / HR. DP8 ALLOWABLE WALL DEFLECTIONS: EXTERIOR (CLADDING DESIGN)L/360 (BRICK VENEER DESIGN)L/600 ≤0.3" INTERIOR L/360 DP9 ALLOWABLE FRAMING DEFLECTIONS: ROOF LIVE LOAD L/360 ROOF TOTAL LOAD L/240 FLOOR LIVE LOAD L/360 FLOOR TOTAL LOAD L/240 DP10 ASSUMED FUTURE CONSTRUCTION: VERTICAL NONE HORIZONTAL NONE I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PROFESSIONAL SUPERVISION AND THAT I AM A DULY REGISTERED PROFESSIONAL ENGINEER IN THE STATE OF IOWA THIS NOTICE COVERS DWGS: S-SERIES SHEETS SIGNATURE: NAME: DATE: 11/30/2021 MY REGISTRATION EXPIRES IN IOWA: 12/31/22 BRIAN THOMAS, P.E. BRIAN THOMAS 20805 SSEFORPDESNECI L I O W A REEN I G N E LA NOI DATE:DRAWN BY: CHK'D BY: REVISED: RAKER RHODES ENGINEERING, LLC Des Moines IA. 50312 P:(515) 277-0275 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com C: \ U s e r s \ b t h o m a s \ D o c u m e n t s \ R R E 2 1 4 9 0 _ D u b u q u e C o o p e r a t i v e L i v i n g _ R 2 0 _ b t h o m a s @ r a k e r r h o d e s . c o m . r v t 11 / 2 9 / 2 0 2 1 1 2 : 1 4 : 3 9 P M RRE21490 ST R U C T U R A L N O T E S 11/30/2021 BT ER S001 NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E F1 F1 F1 F1 F1 F2F2 F3 F1 F3 F3 F4 F4 F1 F1 F1 F1 F1 F2F2 F3 F1 F3 F3 F4 F4 FOUNDATION SYMBOL KEY T/ WALL/ STEEL T/ FOOTING JOIST BEARING T/ BRICK LEDGE ELEV. STEP EXIST. BLDG. 1 2 3 TOP OF 4" SLAB EL. = [100'-0"] WWF6x6-W2.1xW2.1 S-201 S-201 S-201 5 S201------------------------------------------------------------------------------------------------------------------- 7 S201------------------------------------------------------------------------------------------------------------------- 6 S201------------------------------------------------------------------------------------------------------------------- 5 S201------------------------------------------------------------------------------------------------------------------- 6 S201------------------------------------------------------------------------------------------------------------------- 5 S201------------------------------------------------------------------------------------------------------------------- 99' - 4" 6 S201------------------------------------------------------------------------------------------------------------------- 5 S201------------------------------------------------------------------------------------------------------------------- 5 S201------------------------------------------------------------------------------------------------------------------- 9 S201------------------------------------------------------------------------------------------------------------------- 99' - 4 " 102' - 10"TYP.TYP.6 S201------------------------------------------------------------------------------------------------------------------- 2' - 0 " 6 S201------------------------------------------------------------------------------------------------------------------- 5 S201------------------------------------------------------------------------------------------------------------------- 5' - 0" 2 16x6 WOODPOSTP16x6 WOODPOSTP16x6 WOODPOSTP16x6 WOODPOSTP16x6 WOODPOSTP16x6 WOODPOSTP18 1 2 3 5 4 6 A C D E G H 77' - 6" 14' - 5"16' - 6"7' - 3"21' - 2"14' - 2" 2' - 0 " 11 ' - 6 " 11 ' - 1 1 1 / 2 " 21 ' - 1 0 1 / 2 " 1' - 1 1 3 / 4 " 2' - 1 1 / 4 " 12 9 ' - 1 0 " F 2' - 0" 5 S201------------------------------------------------------------------------------------------------------------------- 99' - 4" 1' - 6" 5 S201------------------------------------------------------------------------------------------------------------------- 1 2 3 TOP OF 4" SLAB EL. = [100'-0"] WWF6x6-W2.1xW2.1 S-201 S-201 S-201 7 5' - 0 " 78 ' - 5 " B 5' - 0 " 5' - 0" 14 ' - 1 1 / 4 " 5' - 0 " 2' - 0" 5' - 8 " 12 ' - 6 1 / 2 " 99' - 4" 2' - 7"11' - 4"2' - 7" 2' - 7"11' - 4"2' - 7" S201 10 S201 10 OPP. 10 ' - 1 " 1' - 9"13' - 0"1' - 9" 8' - 1 3 / 8 " 2 3/4" 5' - 1 1 1 / 2 " 2 3/4" 7' - 1 1 7 / 8 " 1' - 9"13' - 0"1' - 9" F3 F2 5' - 0 " 27 ' - 6 " 18 ' - 7 3 / 4 " 1' - 4 " 5' - 0" 11 S201------------------------------------------------------------------------------------------------------------------- 11 S201------------------------------------------------------------------------------------------------------------------- 11 S201------------------------------------------------------------------------------------------------------------------- 11 S201------------------------------------------------------------------------------------------------------------------- 3/ 8 " 1' - 4 " 1' - 4 " 11 ' - 6 5 / 8 " 1' - 4 " 11 ' - 6 7 / 8 " 1' - 4"8' - 1 5/8" W1 W1 W1 W1 W1 1' - 6" 1' - 6 " PIER SCHEDULE 12" x 12" MARK SIZE P1 (4)-#6 VERT. BARS #3 TIES @ 12" O.C. REINFORCEMENT CMU WALL SCHEDULE #5 @ 48" O.C. MARK WALL SIZE NOTES ---8" VERT. REINFORCEMENT HORIZ. REINFORCEMENT LADDER TYPE @ 16" O.C.W1 NOTES: 1) CMU WALLS SHOWN ON PLAN ARE TYPE W1, U.N.O. 2) SEE STRUCTURAL NOTES FOR NON-LOAD BEARING MASONRY WALL REINFORCEMENT. DATE:DRAWN BY: CHK'D BY: REVISED: RAKER RHODES ENGINEERING, LLC Des Moines IA. 50312 P:(515) 277-0275 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com C: \ U s e r s \ b t h o m a s \ D o c u m e n t s \ R R E 2 1 4 9 0 _ D u b u q u e C o o p e r a t i v e L i v i n g _ R 2 0 _ b t h o m a s @ r a k e r r h o d e s . c o m . r v t 11 / 2 9 / 2 0 2 1 1 2 : 1 4 : 3 9 P M RRE21490 FO U N D A T I O N P L A N 11/30/2021 BT ER S101 PLAN NOTES: 1. SEE SHEET S201 FOR TYPICAL FOUNDATION / SLAB DETAILS 2. PX - INDICATES CONCRETE PIER. SEE PIER SCHEDULE FOR INFORMATION. 3. FX - INDICATES CONCRETE FOOTING. SEE FOOTING SCHEDULE FOR INFORMATION NORTH 1/8" = 1'-0"A FOUNDATION PLAN FOOTING SCHEDULE Type Comments WIDTH LENGTH THICKNESS REINFORCEMENT F1 3' - 0" 3' - 0" 3' - 6"(4) #5's E.W. - BOTTOM F2 5' - 0" 5' - 0" 3' - 6" (6) - #5 E.W. - TOP & BOTTOM F3 7' - 0" 7' - 0" 3' - 6" (8) #5's E.W. - TOP & BOTTOM F4 4' - 0" 4' - 0" 3' - 6" (5) #5's E.W. - TOP & BOTTOM NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E CORNER BARS: MATCH SIZE & SPACING OF HORIZONTAL BARS FOR EACH LAYER OF REINFORCING STANDARD HOOK ALTERNATE ENDS HORIZONTAL BARS: SEE WALL & FOUNDATION SECTIONS FOR REQ'D SIZE & SPACING TYPICAL CLASS B LAP EXTEND INTERIOR HOOKS TO EXTERIOR FACE OF WALL, TYP. TYPICAL CLASS B LAP NOTES: 1. SEE FDN. PLAN FOR SLAB THICKNESS & REINFORCING 2. SEE GENERAL NOTE CN12 FOR JOINT LOCATIONS WWF, SEE PLAN COMPACTED GRANULAR FILL SEE GEOTECHNICAL REPORT6" MIN. COMPACTED SUBGRADE (95%, MIN) SEE GEOTECHNICAL REPORT VAPOR BARRIER SEE ARCH. SLAB ON GRADE, SEE PLAN NOTES: 1. SEE FDN. PLAN FOR SLAB THICKNESS & REINFORCING 2. SEE GENERAL NOTE CN12 FOR JOINT LOCATIONS 1/8" TOOLED RADIUS EDGE COMPACTED GRANULAR FILL SEE GEOTECHNICAL REPORT 6" MIN. COMPACTED SUBGRADE (95%, MIN) SEE GEOTECHNICAL REPORT WWF, SEE PLAN 1/2"Ø x 1' -4" SMOOTH BAR w/ ONE END GREASED @ 16" O.C. LOCATED @ MID-HEIGHT OF SLAB & PERPENDICULAR TO JOINT VAPOR BARRIER SEE ARCH. SLAB ON GRADE, SEE PLAN NOTES: 1. SEE FDN. PLAN FOR SLAB THICKNESS & REINFORCING 2. SEE GENERAL NOTE CN12 FOR JOINT LOCATIONS SAWCUT JOINT WITHIN 12 HOURS OF POUR, SEE PLAN FOR LOCATIONS. DEPTH OF JOINT TO BE THE SMALLER OF 1/4 THE SLAB THICKNESS OR 2". 6" MIN. COMPACTED SUBGRADE (95%, MIN) SEE GEOTECHNICAL REPORT WWF, SEE PLAN VAPOR BARRIER SEE ARCH. SLAB ON GRADE SEE PLAN COMPACTED GRANULAR FILL SEE GEOTECHNICAL REPORT WOOD COLUMN SEE PLAN VERTICAL BARS SEE PIER DETAILS FOR SIZE & SPACING #3 TIES FOOTING SEE PLAN FOOTING REINFORCEMENT SEE SCHEDULE FOR SIZE & SPACING SEE PLAN T/ FOOTING SEE PLAN T/ PIER 2" 2 " 12 " O . C . BRICK VENEER SEE ARCH. SIMPSON ABU66Z w/ 5/8"Ø HILTI HUS EZ COLUMN SEE ARCH EM B E D 1' - 6 " SEE PLAN T/ SLAB SEE PLAN T/ FOOTING WOOD FRAMING SEE PLAN #3 TIES @ 4'-0" O.C. SLAB ON GRADE SEE PLAN (4) #5 CONT, 2T + 2B CONT. BARS THROUGH FOOTINGS & PIERS #4 DOWEL @ 24" O.C. w/ STANDARD HOOK SEE PLAN RIGID INSULATION SEE ARCH. 3' - 6 " NOTES: 1) SEE ARCH FOR NON-STRUCTURAL WALL AND FLOOR COMPONENTS 2) SEE CIVIL FOR TOP OF GRADE WOOD SHEATHING SEE PLAN TREATED 2x SILL PLATE, CONT. SEE PLAN FOR WALL TYPE 1/2"Ø THREADED ROD w/ DOUBLE NUT AND 8" EMBED @ 32" O.C. 2" 2' - 0 " 30" 8" #4 CONT. SEE PLAN T/ SLAB SEE PLAN T/ FOOTING RIGID INSULATION SEE ARCH. SLAB ON GRADE SEE PLAN 8" 5" SLOPE #4 @ 9" O.C. EACH WAY 1'-6" 1'-6" 4" VOID FORM #4 DOWELS @ 24" O.C. #4 @ 12" O.C. (CENTERED) EXPANSION MATERIAL, TYP. 3' - 6 " M I N . ARCH SEE NOTE:CONTRACTOR TO PROVIDE 4" BEARING @ STOOP WALL WHERE EXTERIOR PAVEMENT/SIDEWALK OCCURS. SEE ARCH AND CIVIL DRAWINGS FOR LOCATIONS. S201 5 SEE PLAN SLAB ON GRADE SEE PLAN SEE PLAN T/ SLAB 2x WOOD FRAMING, SEE SCHEDULE (2) #5 CONT. #5 @ 18" O.C. 2x SILL PLATE, SEE SCHEDULE FOR FASTENING 1' - 0 " SEE PLAN SHEATHING, TYP. SEE SCHEDULE 2x STUDS FRAMING w/ (2)-10d T&B, TYP. SEE SCHEDULE TREATED 2x6 SILL PLATE HILTI THREADED HAS ROD w/ HILTI HIT- HY 200 ADHESIVE, SEE SCHEDULE FOR SIZE AND EMBEDMENT SCREWS PER SIMPSON'S SPECIFICATIONS N-PLY 2x STUDS AT SHEAR WALL ENDS FACE NAIL WITH 10d COMMON NAILS SPACED AT 12" O.C. WITH 6" VERTICAL STAGGER EA. SIDE EA. PLY SEE SHEAR WALL SCHEDULE FOR NUMBER OF PLYS SIMPSON HOLDOWN, SEE PLAN FOR LOCATION SEE SCHEDULE FOR SIZE SEE PLAN T/SLAB EPOXY SHEAR WALL HOLDOWN ANCHOR, SEE SCHEDULE PSL STUD, SEE SCHEDULE 2x6 STUDS, SEE SCHEDULE EPOXY SHEAR WALL HOLDOWN ANCHOR, SEE SCHEDULE 1' - 0 " NON LOAD-BEARING CMU WALL SEE ARCH. FOR LOCATIONS NOTE:THICKENED SLAB REQ'D AT ALL NON LOAD-BEARING CMU WALLS. SEE ARCH. DRAWINGS FOR WALL SIZES & LOCATIONS. SEE PLAN T/ SLAB SEE PLAN #4 @ 12" O.C. (2) #4 CONTINUOUS SLAB ON GRADE SEE PLAN #5 x 3'-0" DOWELS w/ HILTI HIT-HY 200 EPOXY (6" MIN. EMBED) MATCH VERT. BAR SPACING DATE:DRAWN BY: CHK'D BY: REVISED: RAKER RHODES ENGINEERING, LLC Des Moines IA. 50312 P:(515) 277-0275 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com C: \ U s e r s \ b t h o m a s \ D o c u m e n t s \ R R E 2 1 4 9 0 _ D u b u q u e C o o p e r a t i v e L i v i n g _ R 2 0 _ b t h o m a s @ r a k e r r h o d e s . c o m . r v t 11 / 2 9 / 2 0 2 1 1 2 : 1 4 : 3 9 P M RRE21490 FO U N D A T I O N D E T A I L S 11/30/2021 BT ER S201 1/2" = 1'-0"4 TYP. REINFORCING @ CORNERS 1 1/2" = 1'-0"1 TYP. SLAB ON GRADE 1 1/2" = 1'-0"2 TYP. SLAB ON GRADE CONSTRUCTION JOINT 1 1/2" = 1'-0"3 TYP. SLAB ON GRADE CONTROL JOINT 3/4" = 1'-0"9 TYP. CONCRETE PIER 3/4" = 1'-0"5 PERIMETER FOOTING @ WOOD FRAMING 1/2" = 1'-0"6 TYP. STOOP SECTION 3/4" = 1'-0"7 TYP. THICKENED SLAB @ WOOD BEARING/SHEAR WALL 3/4" = 1'-0"8 SHEAR WALL HOLDOWN TO CONCRETE 1" = 1'-0"10 SHEARWALL HOLDOWN DETAIL 3/4" = 1'-0"11 TYP. THICKENED SLAB @ NON LOAD-BEARING CMU NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E H3 H3 H2 H2 H2 H2 H2 H2 H1 H2 H1H1H1 H1 H1 H1 H1 H1 H1 H1 H1 H1 30 " P A R A L L E L C H O R D P R E -FA B R I C A T E D R O O F T R U S S E S @ 1 6 " O . C . PR E -FA B R I C A T E D R O O F T R U S S E S @2 4 " O . C . PRE-FABRICATED ROOF TRUSSES @24" O.C. PR E -FA B R I C A T E D P A R A L L E L C H O R D R O O F T R U S S E S @2 4 " O . C . TR U S S P R O F I L E ' C ' SE E 1 3 / S 4 0 1 TR U S S P R O F I L E ' A ' SE E 9 / S 4 0 1 TR U S S P R O F I L E ' B ' SE E 9 / S 4 0 1 TRUSS PROFILE 'E' SEE 14/S401 TRUSS PROFILE 'D' SEE 14/S401 H1 34 " P A R A L L E L C H O R D T R U S S E S @2 4 " O . C . PRE-FABRICATED ROOF TRUSSES@24" O.C. H1 PRE-FABRICATED ROOF TRUSSES@24" O.C. 34 " P A R A L L E L C H O R D T R U S S E S @2 4 " O . C . GIRDER TRUSS GI R D E R T R U S S ST E P B O T T O M CH O R D O F T R U S S , SE E A R C H . OVERFRAMING BY TRUSS SUPPLIER 6 S401------------------------------------------------------------------------------------------------------------------- 7 S401------------------------------------------------------------------------------------------------------------------- 7 S401-------------------------------------------------------------------------------------------------------------------TRUSS BEARING EL. 113'-0 3/4" TRUSS BEARING EL. 113'-0 3/4" TRUSS BEARING EL. 110'-1 1/8" TRUSS BEARING EL. 110'-1 1/8" 6 S401------------------------------------------------------------------------------------------------------------------- TRUSS BEARING EL. 110'-1 1/8" TRUSS BEARING EL. 110'-1 1/8" 2 2 5 1 4 STEP BOTTOM CHORD OF TRUSS, SEE ARCH. 6 S401------------------------------------------------------------------------------------------------------------------- D- 1 D-1 8 1 2 3 5 4 6 A C D E G HF 77' - 6" 7 B 2' - 0"14' - 5"16' - 6"7' - 3"21' - 2"14' - 2"2' - 0" 12 9 ' - 1 0 " 2' - 0 " 11 ' - 6 " 11 ' - 1 1 1 / 2 " 21 ' - 1 0 1 / 2 " 1' - 1 1 3 / 4 " 2' - 1 1 / 4 " 78 ' - 5 " FALSE DORMER OVER FRAMING BY CONTRACTOR GABLE END WALL TRUSS, BY TRUSS SUPPLIER BALLOON FRAME END STUD WALL WITH LSL STUDS, BY CONTRACTOR S301 C S301 B 4 4 3 3 10 S401------------------------------------------------------------------------------------------------------------------- 11 S401------------------------------------------------------------------------------------------------------------------- GI R D E R T R U S S OVERFRAMING BY TRUSS SUPPLIER GI R D E R T R U S S GABLE END WALL TRUSS, BY TRUSS SUPPLIER GI R D E R T R U S S ATTIC/MECH STORAGE GIRDER TRUSS GIRDER TRUSS 12 S401------------------------------------------------------------------------------------------------------------------- WOOD SHEAR WALL SCHEDULE STUD SIZE AND SPACING 2x6 @ 16" O.C. MARK 1 5/8" OSB -EXTERIOR BLOCKED 10d NAILS AT ALL PANEL EDGES, TOP AND BOTTOM PLATES, & BLOCKING, U.N.O. 10d NAILS @ 12" O.C. MAX. IN THE FIELD (ALL PANEL EDGES TO BE BLOCKED WITH 2x OR WIDER FRAMING, U.N.O.) NAILS SHALL BE 3/8" FROM PANEL EDGE 10d @ 6" O.C. EDGES (1)-5/8" Ø HILTI HUS-EZ ANCHOR @ 48" O.C. (4 1/4" EMBED.) HOLD DOWN @ EA. END OF WALL (LOCATIONS SHOWN AS ON PLAN) HILTI HIT-RE 500 V3 ADHESIVE w/ THREADED HAS ROD SEE DETAIL NOTES: 1) SEE ARCH. DRAWINGS FOR NON-STRUCTURAL COMPONENTS (I.E. GYP. BOARD, RESILIENT CHANNELS, ETC.). 2) SEE DETAIL FOR TYPICAL BUILT-UP 2x FRAMING SCHEME. 3) SEE DETAIL FOR TYPICAL WOOD SHEAR WALL ASSEMBLY. 2x6 @ 16" O.C. 2 5/8" OSB -ONE SIDE BLOCKED 10d @ 4" O.C. EDGES (1)-5/8" Ø HILTI HUS-EZ ANCHOR @ 32" O.C. (4 1/4" EMBED.) SIMPSON HDU5-SDS2.5 w/ (14)-SDS1/4x3 SCREWS w/ 5/8" Ø A36 THEADED ROD (10 1/2" EMBED.) w/ (2)-PLY 2x6 POST SHEATHING TYPE BLOCKED OR UNBLOCKED SILL PLATE CONNECTION @ TOPPING/PRECAST /8 S201 /1 S401 /5 S401 2x6 @ 16" O.C. 3 5/8" OSB -BOTH SIDES BLOCKED 10d @ 4" O.C. EDGES 1/2"Ø A36 THREADED ROD w/ DOUBLE NUT AND 8" EMBED @ 32" O.C. SIMPSON HDU14-SDS2.5 w/ (36)-SDS1/4x2.5 SCREWS w/ 1" Ø HILTI HAS ROD (10 1/2" EMBED.) w/ (1) 6x6 WOOD POST 2x6 @ 16" O.C. 4 5/8" OSB -EXERIOR BLOCKED 10d @ 4" O.C. EDGES SIMPSON HDU5-SDS2.5 w/ (14)-SDS1/4x3 SCREWS w/ 5/8" Ø A36 THEADED ROD (10 1/2" EMBED.) w/ (2)-PLY 2x6 POST 1/2"Ø A36 THREADED ROD w/ DOUBLE NUT AND 8" EMBED @ 32" O.C. SIMPSON HDU11-SDS2.5 w/ (30)-SDS1/4x3 SCREWS w/ 1" Ø A36 THEADED ROD (10 1/2" EMBED.) w/ (3)-PLY 2x6 POST 3 1/2" x 7 1/4" 1.3E TimberStrand® LSL @ 16" OC. 5 5/8" OSB -BOTH SIDES BLOCKED 10d @ 4" O.C. EDGES 1/2"Ø A36 THREADED ROD w/ DOUBLE NUT AND 8" EMBED @ 32" O.C. SIMPSON HDU14-SDS2.5 w/ (36)-SDS1/4x2.5 SCREWS w/ 1" Ø HILTI HAS ROD (10 1/2" EMBED.) w/ (2) 3 1/2" x 7 1/4" 1.3E TimberStrand® LSL H1 WOOD HEADER SCHEDULE (3)-2x12 w/ (2)-2x6 FULL HEIGHT STUDS + (2)-2x6 JACK STUDS @ EA. JAMB --- MARK SIZE NOTES H2 (3)-1 3/4" x 14" w/ (3)-2x6 FULL HEIGHT STUDS + (2)-2x6 JACK STUDS @ EA. JAMB --- H3 (4)-1 3/4" x 14" w/ (2)-3 1/2x 71/4 LSL FULL HEIGHT STUDS + (2)-2x6 JACK STUDS @ EA. JAMB --- WOOD SHEATHING SCHEDULE D-1 MARK TYPE DETAILS NOTES 5/8" OSB SHEATHING SEE WF GENERAL STRUCTURAL NOTES AT ROOF 1 2 A C DB (3 ) 1 3 / 4 x 1 1 7 / 8 L V L (3 ) 1 3 / 4 x 1 1 7 / 8 L V L (3)1 3/4x11 7/8 LVL (3 ) 1 3 / 4 x 1 1 7 / 8 L V L SIMPSON POST CAP BC6, TYP. SIMPSON HANGER HHUS5.50/10 PARALLEL CHORD END WALL TRUSS AT ENTRY WALL 5 6 A C D 7 B HIP GIRDER TRUSS (3)1 3/4x11 7/8 LVL (3 ) 1 3 / 4 x 1 1 7 / 8 L V L (3 ) 1 3 / 4 x 1 1 7 / 8 L V L (3 ) 1 3 / 4 x 1 1 7 / 8 L V L SIMPSON POST CAP BC6, TYP. SIMPSON HANGER HHUS5.50/10 PARALLEL CHORD END WALL TRUSS AT ENTRY WALL W3 102.1 E6A E3A E3A E3A E1A W5 DATE:DRAWN BY: CHK'D BY: REVISED: RAKER RHODES ENGINEERING, LLC Des Moines IA. 50312 P:(515) 277-0275 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com C: \ U s e r s \ b t h o m a s \ D o c u m e n t s \ R R E 2 1 4 9 0 _ D u b u q u e C o o p e r a t i v e L i v i n g _ R 2 0 _ b t h o m a s @ r a k e r r h o d e s . c o m . r v t 11 / 2 9 / 2 0 2 1 1 2 : 1 4 : 4 0 P M RRE21490 FR A M I N G P L A N 11/30/2021 BT ER S301 PLAN NOTES: 1. 2. SEE SHEET S401 FOR TYPICAL FRAMING DETAILS. 3. TRUSS BEARING ELEVATION = 110'-1 1/8" U.N.O. 4. DESIGN TRUSSES & BRACING FOR 5 PSF NET UPLIFT. 5. ROOF TRUSS LAYOUT FOR BIDDING PURPOSES ONLY. CONTRACTOR TO PROVIDE FINAL LAYOUT. 6. ALL EXTERIOR WALLS TO BE CONSTRUCTED USING FASTENER LAYOUT PER SHEAR WALL TYPE 1, U.N.O. NORTH 1/8" = 1'-0"A ROOF FRAMING PLAN NORTH 1/4" = 1'-0"B ROOF FRAMING PLAN NORTH 1/4" = 1'-0"C ROOF FRAMING PLAN NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E 12d @ 8" O.C. STAGGERED EA. SIDE (2) -2x STUDS (MAY BE USED IN LIEU OF (1) -3x STUD) (3) -2x STUDS 8" 8 " 1 1/2" MIN. 1 1/2" MIN. 2X4 STUD ELEVATION (2) ROWS 12d @ 8" O.C. EA. SIDE 1 1/2" MIN. 1 1/2" MIN. 2X6 OR LARGER STUD ELEVATION (4) -2x STUDS 8" 8" 8"8" DIST. 2 1/2" END DIST. 2 1/2" END 8" 8" 2x FRAMING, TYP. SEE SCHEDULE SIMPSON LSTA18 ON INTERIOR FACE CENTERED @ SPLICE SPLICE MIN. SPLICE 4' - 0" 10d NAILS @ 12" O.C. SPLICE SIMPSON LSTA18 ON INTERIOR FACE CENTERED @ SPLICE SEE PLAN T/ PLATE DOUBLE 2x TOP PLATE PLY 2x HEADER WITH 1/2" PLYWOOD SPACERS TO MATCH 2x STUD WIDTH FULL HEIGHT 2x4 OR 2x6 STUDS SEE HEADER SCHEDULE FASTEN HEADER TO STUDS WITH (6) -10d COMMON NAILS @ EACH END JACK STUDS -FACE NAIL DOUBLE STUDS WITH 16d COMMON NAILS @ 24" O.C. SEE HEADER SCHEDULE 2x FRAMING @ 16" O.C. (TYP.) 16d COMMON NAILS @ 16" O.C. @ TOP AND BOTTOM (STAGGERED) w/(3) 16d NAILS @ EACH END NOTE:KING AND JACK STUDS SHALL BE CONTINUOUS FOR ALL FLOORS BELOW HEADER. SEE ARCH. B/ HEADER 2x DOUBLE TOP PLATE. SEE ARCH. NUMBER OF STUDS TO MATCH STUDS @ POSTS AND JAMBS ABOVE DIAPHRAGM BOUNDARY STRUCTURAL PANEL SHEATHING ONE SIDE ONLY SEE PLAN FOR THICKNESS AND GRADE 10d COMMON NAILS SPACED @ MAXIMUM 6" O.C. @ DIAPHRAGM BOUNDARY AND SUPPORTED EDGES 10d COMMON NAILS SPACED @ 12" O.C. MAX @ INTERMEDIATE FRAMING MEMBERS THIS PANEL JOINT NOT CONTINUOUS CONTINUOUS PANEL JOINT ROOF TRUSSES, TYP. PANEL EDGE NAILING SEE SCHEDULE FOR PATTERN NAILS NO LESS THAN 3/8" FROM PANEL EDGES 2x STUDS FRAMING, SEE SCHEDULE (TYPICAL) w/ (2) -8d TOE NAILS @ EACH END WOOD STRUCTURAL PANEL SHEATHING SEE SCHEDULE HOLD DOWNS -SEE PLAN FOR LOCATION AND SEE SCHEDULE FOR TYPE N-PLY 2x STUDS @ SHEAR WALL ENDS, TYP. PANEL BLOCKING AS REQ'D, SEE SCHEDULE INTERMEDIATE FIELD NAILS @ 12" O.C., TYPICAL SILL PLATE ANCHORS TYP. SEE SCHEDULES201 8 SEE ARCH SEE PLAN TRUSS BEARING PRE-ENGINEERED WOOD ROOF TRUSSES BY CONTRACTOR, SEE PLAN TRUSS UPLIFT CALCULATION IS THE RESPONSIBILITY OF CONTRACTOR. 2x BLOCKING SHALL BE ADDED @ EVERY OTHER TRUSS SPACE -NAIL TO TOP PLATE AND SHEATHING, FIT TIGHT BETWEEN EA. TRUSS OSB ROOF SHEATHING, SEE PLAN TRUSS TIE DOWN: SEE NOTE BELOW TYPICAL TRUSS = SIMPSON H2.5A GIRDER TRUSS = SIMPSON MGT w/ HDU4 NOTE:TIE DOWNS ARE FOR ESTIMATING PURPOSES ONLY. FINAL DESIGN SHALL BE DETERMINED AFTER TRUSS UPLIFT CALCULATIONS ARE PROVIDED BY CONTRACTOR. SHEATHING, SEE SCHEDULE 2x WOOD FRAMING, SEE SCHEDULE DOUBLE 2x TOP PLATE SEE ARCH. SEE ARCH SEE PLAN TRUSS BEARING PRE-ENGINEERED WOOD ROOF TRUSSES BY CONTRACTOR, SEE PLAN TRUSS UPLIFT CALCULATION IS THE RESPONSIBILITY OF CONTRACTOR. 2x BLOCKING SHALL BE ADDED @ EVERY OTHER TRUSS SPACE -NAIL TO TOP PLATE AND SHEATHING, FIT TIGHT BETWEEN EA. TRUSS OSB ROOF SHEATHING, SEE PLAN TRUSS TIE DOWN: SEE NOTE BELOW TYPICAL TRUSS = SIMPSON H2.5A GIRDER TRUSS = SIMPSON MGT w/ HDU4 NOTE:TIE DOWNS ARE FOR ESTIMATING PURPOSES ONLY. FINAL DESIGN SHALL BE DETERMINED AFTER TRUSS UPLIFT CALCULATIONS ARE PROVIDED BY CONTRACTOR. SHEATHING, SEE SCHEDULE 2x WOOD FRAMING, SEE SCHEDULE DOUBLE 2x TOP PLATE SEE ARCH. ROOF SHEATHING AND NAILING PER STRUCTURAL NOTES PRE-ENGINEERED WOOD ROOF TRUSS BY CONTRACTOR, SEE PLAN WOOD SHEATHING SEE SCHEDULE SEE PLAN TRUSS BEARING 1/4"x3" SDS SCREWS @ 16" O.C., TYP. WOOD FRAMING SEE SCHEDULE 1/4"x3" SDS SCREWS @ 16" O.C., TYP. 1/2" OSB AT SHEAR WALL LOCATIONS, SEE PLAN 2x4 BLOCKING w/ 1/4"x3" SDS SCREWS @ 16" O.C., TYP. /2 S401DOUBLE 2x TOP PLATE SEE DETAIL FOR TOP PLATE SPLICE DETAIL EXTEND WALL WOOD SHEATHING TO ROOF SHEATHING, SEE SCHEDULE 2x4 BRACE @ 48" O.C. ARCH SEE PRE-ENGINEERED WOOD ROOF TRUSSES BY CONTRACTOR, SEE PLAN OSB ROOF SHEATHING, SEE PLAN BALLON FRAMED LSL WALL, SEE SCHEDULE OUTLOOKER FRAMING, SEE ARCH. (2) 2x8 TOP PLATE EXTEND WALL WOOD SHEATHING TO UPPER ROOF SHEATHING, SEE SCHEDULE 2x4 BRACE @ 48" O.C. ARCH SEE PRE-ENGINEERED WOOD ROOF TRUSSES BY CONTRACTOR, SEE PLAN OSB ROOF SHEATHING, SEE PLAN OUTLOOKER FRAMING, SEE ARCH. (2) 2x6 TOP PLATE, SLOPE WITH ROOF SEE PLAN TRUSS BEARING VARIES 2x6xCONT. LEDGER w/ (2) SIMPSON SDS 1/4x5 SCREWS @ EACH STUD (SDS25500) 2X6 STUD FRAMING, SEE SCHEDULE (2) 2x6 TOP PLATE 2x6 BOTTOM PLATE ROOF TRUSSES OVER FRAMING TRUSSES TRUSS PROFILE 'A' 12 7 1/2 12 7 1/2 MINIMUM 1'-6". MINIMUM 1'-6". TRUSS PROFILE 'B' OVER FRAMING TRUSSES GIRDER TRUSS GIRDER TRUSS MONO ROOF TRUSS STEPPED BOTTOM CHORD OVER FRAMING TRUSS MONO ROOF TRUSS GIRDER TRUSS GIRDER TRUSS GIRDER TRUSS GIRDER TRUSS ROOF TRUSSES 12 7 1/2 12 7 1/2 TRUSS PROFILE 'C' SEE PLAN 12 7 1/2 2' - 5 1/4" 2 ' - 4 " TRUSS PROFILE 'D' ATTIC/ MECH STORAGE STEPPED BOTTOM CHORD GIRDER TRUSS MAX SHIPPING HEIGHT TRUSS PROFILE 'E' BY TRUSS SUPPLIER 12" WOOD TRUSSES @ 24" O.C., BY TRUSS SUPPIER (20-10-5) LOADING INFILL ROOF TRUSSES 12 7 1/2 1' - 0" 8' - 0" GIRDER TRUSS 3/4" OSB SHEATHING SEE ARCH. 2x FRAMING, SEE SCHEDULE ROOF SHEATHING SEE PLAN GABLE END TRUSS w/ INFILL VERTICALS @ 16" O.C. (MAX) BY TRUSS SUPPLIER DOUBLE 2x TOP PL SIMPSON GBC ON EA. SIDE OF BRACE @ EA. BRACE PROVIDE BLOCKING FOR CEILING ATTACHEMENT AS REQUIRED 2x6 BRACE @ 2'-8" SECONDARY 2x6 BRACE @ 2'-8" O.C. WHERE GABLE HEIGHT IS > 6'-6" 2x BLOCKING @ EVERY JOIST SPACE (CUT TO FIT TIGHT & TOENAIL) TYP. 40°-45° GABLE MID-HEIGHT (4)-16d NAILS 10d NAILS @ 4" O.C. CONT. RIM BOARD, SEE ARCH. (3) -16d NAILS HORIZONTAL BRACE AS REQUIRED, SEE TRUSS SHOPS FASTEN GABLE TRUSS TO TOP PLACE w/ SIMPSON A35 CLIP @ 2'-0" O.C. ADD 2x4 BRACING @ 6'-0" O.C. MAX PRE-ENGINEERED TRUSSES @ 24" O.C. 2x6 @ EA. BRACE w/ SIMPSON LB26 @ EA. END SEE PLAN T/ WALL DATE:DRAWN BY: CHK'D BY: REVISED: RAKER RHODES ENGINEERING, LLC Des Moines IA. 50312 P:(515) 277-0275 1605 N. ANKENY BLVD #130 ANKENY, IOWA 50023 PHONE: (515) 965-5336 FAX: (515) 965-5335 info@imprintarchitects.com C: \ U s e r s \ b t h o m a s \ D o c u m e n t s \ R R E 2 1 4 9 0 _ D u b u q u e C o o p e r a t i v e L i v i n g _ R 2 0 _ b t h o m a s @ r a k e r r h o d e s . c o m . r v t 11 / 2 9 / 2 0 2 1 1 2 : 1 4 : 4 0 P M RRE21490 FR A M I N G D E T A I L S 11/30/2021 BT ER S401 3/4" = 1'-0"1 BUILT UP 2x FRAMING 1/2" = 1'-0"2 TOP PLATE SPLICE 3/4" = 1'-0"3 TYPICAL HEADER DETAIL 1/4" = 1'-0"4 WOOD ROOF DIAPHRAGM NAILING N.T.S.5 TYP. WOOD SHEAR WALL ELEVATION 3/4" = 1'-0"6 PERIMETER ROOF FRAMING 3/4" = 1'-0"7 PERIMETER ROOF FRAMING 3/4" = 1'-0"8 ROOF TRUSS CONNECTION TO SHEAR WALL 3/4" = 1'-0"10 EAVE FRAMING DETAIL @ BALOON FRAMING 3/4" = 1'-0"11 FRAMING DETAIL 1/4" = 1'-0"9 TRUSS PROFILES 'A' & 'B' 3/16" = 1'-0"13 TRUSS PROFILE 'C'3/16" = 1'-0"14 TRUSS PROFILE 'D' & 'E' 3/4" = 1'-0"12 GABLE END FRAMING DETAIL NOT FOR CONSTRUCTION PR O J E C T : WA U K E E CO O P C L U B H O U S E