Loading...
HomeMy WebLinkAbout2022-06-20 G01 Petersen Townhomes Rezoning_PH AGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: June 20, 2022 AGENDA ITEM: Public hearing on an ordinance to amend Chapter 169, Zoning Ordinance, City of Waukee, Iowa, by rezoning certain property from R-2 (One and Two-Family Residential District) / PD-1 (Planned Development Overlay) and R-4 (Row Dwelling & Townhome District) / PD-1 (Planned Development Overlay) to R-4 (Row Dwelling & Townhome District) / PD-1 (Planned Development Overlay) [Petersen Townhomes] FORMAT: Public Hearing SYNOPSIS INCLUDING PRO & CON: The subject property is located south of NW Douglas Parkway and west of NW 10th Street. The property is approximately 20.96-acres in area and is currently in agricultural use. The applicant and property owner request that 20.96-acres of the property be rezoned from R-2/PD-1 and R-4/PD-1 to R-4/PD-1. The subject property was originally rezoned in Fall 2021, however, due to some existing site constraints, the layout for the development and zoning is proposed to be revised. In May 2022, the Commission reviewed and approved a preliminary plat for Alder Point, which is the single-family portion of the property. The applicant has submitted consent from 69.17% of property owners within 250-feet of the area proposed to be rezoned. Notification to adjacent property owners was mailed on June 3, 2022. The rezoning sign was placed on the property by the June 6, 2022, deadline. Staff has not received any correspondence regarding this request. The concept plan identifies 114 potential townhome units within the area proposed to be zoned R- 4/PD-1. A limited amount of the units will be access from private streets. The remaining units would be accessed from internal private streets. Due to some of the unique characteristics of the proposed development, a planned development overlay has been requested. The Planned Development Agreement requires the following provisions for the PD areas:  Minimum two car garage along units facing public streets, one-car garages are allowed along private streets;  Adjacent buildings must incorporate different materials and/or colors;  Minimum of 20% stone, brick, or stucco on the front of the home facing the street;  Specific requirements for the use of vinyl siding (0.042-inch thickness);  An outdoor space for each unit shall be provided;  Attached and detached townhomes are allowed. A number of public street extensions would occur as part of this development. Two main collector streets would provide primary access in and out of the development. Streets within the townhome portion would be private streets. Previously, the Commission reviewed and approved a preliminary plat for Alder Point, which is the single-family portion of the property that will construct the public streets. G1 Public utilities are available to service the proposed development. Stormwater management is shown to be provided in a basin on the south side of the property. Parkland dedication requirements will apply to the project because of its residential nature. The required amount of parkland is 2.42-acres. The Greenbelt area shown on the south side of the property is shown to be 3.59-acres in area. The applicant proposes to dedicate this area to the City for parkland. An existing pedestrian underpass was installed as part of the improvements to NW 10th Street. The intent of the City would be to install a trail through this greenbelt and connect to the underpass. Further trail extensions will occur to the west and into the parkland located within Stratford Crossing. The subject property is classified as Medium Density Residential and Open Space in the Imagine Waukee 2040: Comprehensive Plan. The densities of the three townhome areas proposed is 5.4 units per acre which is within the range identified in the Comprehensive Plan and under the maximum allowed of 12 units per acre within the R-4 district. The areas to be dedicated to the City for parkland dedication purposes are consistent with those areas identified as Open Space on the Future Land Use Map. The subject property was included as part of the overall Northwest Neighborhood Master Plan that was approved in early 2022. The Master Plan identified the property for townhome development. The proposed zoning is consistent with the neighborhood plan as well. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning Commission reviewed the rezoning request on June 14, 2022, and recommended approval: Approval of a Rezoning related to a change from R-2 (One & Two Family Residential District)/ PD-1 (Planned Development Overlay) and R-4 (Row Dwelling & Townhome District)/ PD-1 (Planned Development Overlay) to R-4 (Row Dwelling & Townhome District)/ PD-1 (Planned Development Overlay) [Petersen Townhomes] Community Development Director, Andy Kass, introduced the request for approval of a rezoning for a townhome development. The property is generally located south of NW Douglas Parkway and west of NW 10th Street, containing approximately 20.96 acres. The area was recently included in a rezoning in Fall of 2021; however, some site constraints have required the layout for the development and zoning to be revised. Notification regarding the rezoning was sent to adjacent property owners on June 3rd, 2022. The applicant has submitted approval from approximately 69.17% of property owners within 250 feet of the property. To date staff has not received any correspondence for or against the request. Mr. Kass advised that the concept plan identifies a total of 114 townhome units proposed to be zoned R-4/PD-1. The Planned development overlay would allow for a limited number of units that do not face public streets to have one-car garages. The planned development overlay also identifies specifications for building materials and the requirement of an outdoor space for each unit. The project identifies several public street extensions around the site and the creation of private streets internal to the site to be owned and maintained by the owner’s association. Public utilities are available to be extended to the site and stormwater detention is shown to be contained in a basin on the south side of the property. A greenbelt area on the south side of the property is shown to satisfy parkland dedication requirements. At this time staff would recommend approval of a rezoning for the Petersen Townhomes.  Commissioner Inman questioned if this product would be similar to Grey’s Station. A representative for the applicant advised that was correct, it would have a similar feel, but that the point of the development was to bring something a little more urban to their property.  Commissioner Tessau questioned the square footage of the units. Mr. Kass advised that the units ranged from 1200 to 1800 square feet. The applicant’s representative, Matt Weller, advised that the purpose of the one car garage was to allow for more main floor living space.  Commissioner Hoifeldt questioned about the cell tower location and potential future intent. Whether the applicant would be returning to rezone this one portion yet again in the future to allow for a single-family home as presented on the previous rezoning. Both the Mr. Weller and Mr. Kass advised that technically a zoning change wouldn’t be required for a home to be constructed on the subject lot, however if that portion was left out at the present, it would have caused unusual zoning amendments to be needed in other areas. In the future it is also a potential that the lot remains green space depending on how fast the neighborhood builds out and how long the cellular tower lease holds viability. Commissioner Hoifeldt moved to approve the rezoning related to a change from R-2 (One- & Two-Family Residential District)/ PD-1 (Planned Development Overlay) and R-4 (Row Dwelling & Townhome District)/ PD-1 (Planned Development Overlay) to R-4 (Row Dwelling & Townhome District)/ PD-1 (Planned Development Overlay) [Petersen Townhomes]. Commissioner Broderick seconded the motion. Ayes: Hoifeldt, Inman, Broderick, Koshy, and Tessau. Nays: none. Motion Carried. STAFF REVIEW AND COMMENT: Staff would recommend approval of the proposed rezoning request based on its conformance with the Comprehensive Plan. RECOMMENDATION: Hold the Public Hearing. ATTACHMENTS: I. Staff Report II. Rezoning Map III. Concept Plan IV. Planned Development V. Elevations PREPARED BY: Andy Kass, Community Development Director REVIEWED BY: PUBLIC NOTICE INFORMATION – NAME OF PUBLICATION: Dallas County News DATE OF PUBLICATION: June 9, 2022 PLANNING AND ZONING COMMISSION STAFF REPORT PROJECT: Petersen Townhomes – Rezoning PREPARED BY: Andy Kass AICP, Community Development Director REPORT DATE: June 10, 2022 MEETING DATE: June 14, 2022 GENERAL INFORMATION Applicant: Hubbell Realty Company Owner: HRC Alder Point, LLC Owner’s Representative: Ryan Hardisty, PE – Civil Design Advantage Request: The applicant is requesting approval of a rezoning for a townhome development Location and Size: Property is generally located south of NW Douglas Parkway and west of NW 10th Street, containing approximately 20.96-acres. AREA MAP ABOVE LEFT: Concept plan of the development identifying the area proposed to be rezoned. The area outlined in BLUE is the area proposed to be rezoned. June 16, 2022 2 of 3 LAND USES AND ZONING Location Existing Land Use Comprehensive Plan Current Zoning Property in Question Vacant - Undeveloped Single Family Residential, Medium Density Residential, & Open Space R-2 (One & Two Family Residential District) / PD-1 (Planned Development Overlay) & R-4 (Row Dwelling & Townhome District) / PD-1 (Planned Development Overlay) North Undeveloped Single Family Residential A-1 (Agricultural District) South Stratford Crossing Medium Density Residential & Open Space R-3 (Multi-Family Residential District) & C- 1 (Community & Highway Service District) East Triumph Park / NW High School Institutional A-1 (Agricultural District) West Stratford Crossing Single Family Residential R-2 (One & Two Family Residential District) / PD-1 (Planned Development Overlay) BACKGROUND The subject property is located south of NW Douglas Parkway and west of NW 10th Street. The property is approximately 20.96-acres in area and is currently in agricultural use. The applicant and property owner request that 20.96-acres of the property be rezoned from R-2/PD-1 and R-4/PD-1 to R-4/PD-1. The subject property was originally rezoned in Fall 2021, however, due to some existing site constraints, the layout for the development and zoning is proposed to be revised. In May 2022, the Commission reviewed and approved a preliminary plat for Alder Point, which is the single-family portion of the property. The applicant has submitted consent from 69.17% of property owners within 250-feet of the area proposed to be rezoned. Notification to adjacent property owners was mailed on June 3, 2022. The rezoning sign was placed on the property by the June 6, 2022, deadline. Staff has not received any correspondence regarding this request. PROJECT DESCRIPTION The concept plan identifies 114 potential townhome units within the area proposed to be zoned R-4/PD-1. A limited amount of the units will be access from private streets. The remaining units would be accessed from internal private streets. Due to some of the unique characteristics of the proposed development, a planned development overlay has been requested. Table 1 below outlines the bulk regulations for the development. The Planned Development Agreement requires the following provisions for the PD areas: R-4/PD-1  Minimum two car garage along units facing public streets, one-car garages are allowed along private streets;  Adjacent buildings must incorporate different materials and/or colors;  Minimum of 20% stone, brick, or stucco on the front of the home facing the street;  Specific requirements for the use of vinyl siding (0.042-inch thickness);  An outdoor space for each unit shall be provided;  Attached and detached townhomes are allowed. June 16, 2022 3 of 3 Table 1: Standard R-4 requirements and proposed R-4/PD-1 requirements. Category Standard R-2/PD-1 (minimum) Proposed R-4/PD-1 Lot Area 3,500 square feet per unit 3,500 square feet per unit Lot Width 20 feet 20 feet Front Yard Setback 30 feet 30-feet along public street / 25 feet along private street Rear Yard Setback 30 feet 30 feet Side Yard Setback 10 feet (total) 12 feet A number of public street extensions would occur as part of this development. Two main collector streets would provide primary access in and out of the development. Streets within the townhome portion would be private streets. Previously, the Commission reviewed and approved a preliminary plat for Alder Point, which is the single-family portion of the property that will construct the public streets. Public utilities are available to service the proposed development. Stormwater management is shown to be provided in a basin on the south side of the property. Parkland dedication requirements will apply to the project because of its residential nature. The required amount of parkland is 2.42-acres. The Greenbelt area shown on the south side of the property is shown to be 3.59-acres in area. The applicant proposes to dedicate this area to the City for parkland. An existing pedestrian underpass was installed as part of the improvements to NW 10th Street. The intent of the City would be to install a trail through this greenbelt and connect to the underpass. Further trail extensions will occur to the west and into the parkland located within Stratford Crossing. COMPREHENSIVE PLAN The subject property is classified as Single Family Residential, Medium Density Residential, and Open Space in the Imagine Waukee 2040: Comprehensive Plan. The comprehensive plan defines the referenced land use classifications as follows:  Single Family Residential is defined as traditional forms of single family housing with lot sizes ranging from 8,000 square feet to 0.50-acres in area with an average density of 2 to 4 units per acre.  Medium Density Residential is defined as a variety of attached side-by-side townhome and row home products with densities ranging from 4 to 12 units per acre.  Open Space is defined as areas intended for park development or open space conservation. The densities of the three townhome areas proposed is 5.4 units per acre which is within the range identified in the Comprehensive Plan and under the maximum allowed of 12 units per acre within the R-4 district. The areas to be dedicated to the City for parkland dedication purposes are consistent with those areas identified as Open Space on the Future Land Use Map. The subject property was included as part of the overall Northwest Neighborhood Master Plan that was approved in early 2022. The Master Plan identified the property for townhome development. The proposed zoning is consistent with the neighborhood plan as well. STAFF RECOMMENDATION The proposed zoning district is generally consistent with the land uses identified in the Comprehensive Plan. Based on the conformance with the Comprehensive Plan staff recommends approval of the rezoning for the Petersen Townhomes. NOTIFICATION BOUNDARY REZONING BOUNDARY NOTIFICATION BOUNDARY REZONING BOUNDARY EXISTING ZONING: A-1 AGRICULTURAL DISTRICT EXISTING ZONING: A-1 AGRICULTURAL DISTRICT EXISTING ZONING: A-1 AGRICULTURAL DISTRICT EXISTING ZONING: R-3 RENTAL MULTI-FAMILY RESIDENTIAL DISTRICT EXISTING ZONING: C-1 COMMUNITY AND HIGHWAY SERVICE COMMERCIAL DISTRICT E X I S T I N G Z O N I N G : R - 2 O N E A N D T W O - F A M I L Y R E S I D E N T I A L D I S T R I C T EX I S T I N G Z O N I N G : R- 2 O N E A N D T W O - F A M I L Y RE S I D E N T I A L D I S T R I C T NW 1 0 T H S T R E E T NW YORKTOWN DRIVE NW W I L L I A M S B U R G L A N E NW DOUGLAS PARKWAY WAUKEE CITY LIMITS NW S T R A T F O R D D R I V E PROPOSED ZONING: PUD 20.96 ACRES CI V I L D E S I G N A D V A N T A G E 2204.289 EN G I N E E R : TE C H : RE V I S I O N S DA T E 11 PU D R E Z O N I N G M A P PE T E R S E N P R O P E R T Y WA U K E E , I O W A SU B M I T T A L # 1 04 / 2 6 / 2 0 2 2 PH O N E : ( 5 1 5 ) 3 6 9 - 4 4 0 0 41 2 1 N W U R B A N D A L E D R I V E UR B A N D A L E , I A 5 0 3 2 2 SU B M I T T A L # 2 06 / 0 1 / 2 0 2 2 WAUKEE, IOWA OWNER ADJACENT OWNERSHIP N. W A R R I O R L A N E VICINITY MAP NW 1 0 T H S T R E E T HICKMAN ROAD SITE APPLICANT ENGINEER ZONING NW DOUGLAS PARKWAY PUD REZONING DESCRIPTION (UNDERLYING R-4) “” “”“”“” “” BULK REGULATIONS · · · · N 1 0 T H S T CL U B H O U S E W/ P O O L WALNUT (3 UNITS) CARBON (2 UNITS) RA N C H ( 3 U N I T S ) RA N C H ( 3 U N I T S ) C A R B O N ( 2 U N I T S ) OUTLOT 'X' DEVELOPMENT SUMMARY UNIT SUMMARY PARKING REQUIREMENTS / CALCULATIONS CI V I L D E S I G N A D V A N T A G E 2204.289 PE T E R S E N M U L T I - F A M I L Y EN G I N E E R : TE C H : RE V I S I O N S DA T E WA U K E E , I O W A 4 1 OU T L O T ' X ' C O N C E P T PH O N E : ( 5 1 5 ) 3 6 9 - 4 4 0 0 41 2 1 N W U R B A N D A L E D R I V E UR B A N D A L E , I A 5 0 3 2 2 BUILDING SQUARE FOOTAGES 12345678 9 10 37 38 39 NW YORKTOWN DR OUT L O T Z PAR K L A N D / G R E E N B E L T (156 , 4 7 7 S F ) CELL TOWE R PARCEL OUTLOT Z - PARKLAND / GREENBELT (156,477 SF) CL U B H O U S E W/ P O O L 20' x 20' MAINTENENCE SHOP WALNUT (3 UNITS) WALNUT (3 UNITS) WALNUT (3 UNITS) WALNUT (3 UNITS) RO O F T O P ( 4 U N I T S ) ROOFTOP (4 UNITS) RO O F T O P (4 U N I T S ) RO C K W E L L ( 4 U N I T S ) ROCKWELL (4 UNITS) ROCKWELL (4 UNITS) ROCKWELL (4 UNITS) ROCKWELL (4 UNITS) CA R B O N ( 4 U N I T S ) CARBON (2 UNITS) RA N C H ( 3 U N I T S ) ROOFTOP (4 UNITS) BIRCH (3 UNITS) CARBON (4 UNITS) CARBON (4 UNITS) CARBON (4 UNITS) CARBON (4 UNITS) CARBON (4 UNITS) WALNUT (3 UNITS) BIRCH (3 UNITS) WALNUT (3 UNITS) BIRCH (3 UNITS) BIRCH (3 UNITS) BIRCH (3 UNITS) BIRCH (3 UNITS) RO O F T O P (4 U N I T S ) RO C K W E L L ( 4 U N I T S ) CI V I L D E S I G N A D V A N T A G E 2204.289 PE T E R S E N M U L T I - F A M I L Y EN G I N E E R : TE C H : RE V I S I O N S DA T E WA U K E E , I O W A 4 2 OU T L O T ' Y ' C O N C E P T PH O N E : ( 5 1 5 ) 3 6 9 - 4 4 0 0 41 2 1 N W U R B A N D A L E D R I V E UR B A N D A L E , I A 5 0 3 2 2 OUTLOT 'Y' DEVELOPMENT SUMMARY UNIT SUMMARY PARKING REQUIREMENTS / CALCULATIONS BUILDING SQUARE FOOTAGES ORDINANCE NO. AN ORDINANCE TO AMEND CHAPTER 169, ZONING ORDINANCE, CITY OF WAUKEE, IOWA BY AMENDING THE ZONING FROM R-2 (ONE & TWO FAMILY RESIDENTIAL DISTRICT) / PD-1 (PLANNED DEVELOPMENT OVERLAY) AND R-4 (ROW DWELLING AND TOWNHOME DWELLING DISTRICT) / PD-1 (PLANNED DEVELOPMENT OVERLAY) TO R-4 (ROW DWELLING AND TOWNHOME DWELLING DISTRICT) / PD-1 (PLANNED DEVELOPMENT OVERLAY) FOR CERTAIN PROPERTY [PETERSEN PROPERTY] BE IT ORDAINED by the Council of the City of Waukee: Section 1. Section 160.02 of Chapter 169, Waukee Municipal Code, Zoning Ordinance of the City, adopting the Official Zoning Map, is hereby amended by amending the zoning from R-2 (One & Two Family Residential District) / PD-1 (Planned Development Overlay District) and R-4 (Row Dwelling and Townhome Dwelling District) / PD-1 (Planned Development Overlay District) to R-4 (Row Dwelling and Townhome Dwelling District) / PD-1 (Planned Development Overlay District) for property legally described as follows: A PART OF THE NORTHEAST QUARTER OF THE NORTHEAST QUARTER, AND A PART OF THE NORTHWEST QUARTER OF THE NORTHEAST QUARTER, AND A PART OF PARCEL ‘A’ OF SAID NORTHEAST QUARTER OF THE NORTHEAST QUARTER AS SHOWN ON THE PLAT OF SURVEY RECORDED IN BOOK 2003, PAGE 59, AND A PART OF TRACT “A” OF SAID NORTHEAST QUARTER OF THE NORTHEAST QUARTER AS SHOWN ON THE PLAT OF SURVEY RECORDED IN BOOK 2003, PAGE 58, ALL BEING IN SECTION 29, TOWNSHIP 79 NORTH, RANGE 26 WEST OF THE FIFTH PRINCIPAL MERIDIAN IN THE CITY OF WAUKEE, DALLAS COUNTY, IOWA AND MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNING AT THE SOUTHWEST CORNER OF SAID TRACT “A”; THENCE SOUTH 00°01'35" EAST ALONG THE WESTERLY LINE OF PARCEL “B” AND TRACT “B” AS SHOWN ON SAID PLAT OF SURVEY RECORDED IN BOOK 2003, PAGE 58, A DISTANCE OF 204.89 FEET TO THE SOUTH LINE OF SAID NORTHEAST QUARTER OF THE NORTHEAST QUARTER; THENCE SOUTH 89°57'31" WEST ALONG SAID SOUTH LINE AND THE SOUTH LINE OF SAID NORTHWEST QUARTER OF THE NORTHEAST QUARTER, 1072.93 FEET; THENCE NORTH 00°06'44" EAST, 585.87 FEET; THENCE NORTH 80°55'12" EAST, 70.76 FEET; THENCE NORTH 59°51'38" EAST, 56.32 FEET; THENCE NORTH 02°38'53" WEST, 128.97 FEET; THENCE NORTH 35°24'01" WEST, 30.00 FEET; THENCE NORTHEASTERLY ALONG A CURVE CONCAVE NORTHWESTERLY WHOSE RADIUS IS 150.00 FEET, WHOSE ARC LENGTH IS 68.42 FEET AND WHOSE CHORD BEARS NORTH 41°31'58" EAST, 67.83 FEET; THENCE SOUTH 61°32'03" EAST, 63.12 FEET; THENCE EASTERLY ALONG A CURVE CONCAVE NORTHERLY WHOSE RADIUS IS 400.00 FEET, WHOSE ARC LENGTH IS 198.79 FEET AND WHOSE CHORD BEARS SOUTH 75°46'18" EAST, 196.75 FEET; THENCE NORTH 89°59'28" EAST, 395.01 FEET; THENCE NORTH 00°01'35" WEST, 265.02 FEET; THENCE NORTHERLY ALONG A CURVE CONCAVE WESTERLY WHOSE RADIUS IS 350.00 FEET, WHOSE ARC LENGTH IS 91.63 FEET AND WHOSE CHORD BEARS NORTH 07°31'35" WEST, 91.37 FEET; THENCE NORTH 15°01'35" WEST, 29.17 FEET; THENCE NORTHERLY ALONG A CURVE CONCAVE EASTERLY WHOSE RADIUS IS 350.00 FEET, WHOSE ARC LENGTH IS 91.63 FEET AND WHOSE CHORD BEARS NORTH 07°31'35" WEST, 91.37 FEET; THENCE NORTH 00°01'35" WEST, 35.63 FEET TO THE SOUTHERLY LINE OF PARCEL 20-98 AS SHOWN ON THE PLAT OF SURVEY RECORDED IN BOOK 2021, PAGE 13204; THENCE NORTH 89°59'28" EAST ALONG SAID SOUTHERLY LINE, 17.21 FEET; THENCE SOUTH 89°27'05" EAST CONTINUING ALONG SAID SOUTHERLY LINE, 184.20 FEET; THENCE SOUTH 00°01'35" EAST, 330.62 FEET; THENCE NORTH 89°58'33" EAST, 65.05 FEET; THENCE SOUTH 00°00'32" EAST, 176.67 FEET; THENCE SOUTH 89°59'28" WEST, 5.00 FEET; THENCE SOUTH 00°01'34" EAST, 380.00 FEET; THENCE NORTH 89°59'28" EAST, 300.00 FEET TO THE WESTERLY RIGHT OF WAY LINE OF NW 10TH STREET; THENCE SOUTH 00°01'35" EAST ALONG SAID WESTERLY RIGHT OF WAY LINE, 146.72 FEET TO THE SOUTHERLY LINE OF SAID TRACT “A”; THENCE SOUTH 85°19'48" WEST ALONG SAID SOUTHERLY LINE, 240.79 FEET TO THE POINT OF BEGINNING AND CONTAINING 20.96 ACRES (912,826 SQUARE FEET). THE PROPERTY IS SUBJECT TO ANY AND ALL EASEMENTS OF RECORD. PROPERTY IS SUBJECT TO ANY AND ALL EASEMENTS OF RECORD. Section 4. Planned Development Agreement. Attached hereto as Exhibit A is the Planned Development Agreement which shall define the minimum standards and requirements of the PD-1 [Planned Development Overlay District] pertaining to the above legally described property. Section 5. Repealer. All ordinances or parts of ordinances in conflict with the provisions of this ordinance are hereby repealed. Section 6. Severability Clause. If any section, provision or part of this ordinance shall be adjudged invalid or unconstitutional, such adjudication shall not affect the validity of the ordinance as a whole or any section, provision, or part thereof not adjudged invalid or unconstitutional. Section 7. Effective Date. This ordinance shall be in effect upon its final passage, approval and publication as provided by law. Passed by the Council this _____ day of __________, 2022, and approved this ____ day of _____________, 2022. Courtney Clarke, Mayor Attest: Rebecca D. Schuett, City Clerk Exhibit A PETERSEN PROPERTY PLANNED DEVELOPMENT CITY OF WAUKEE APPROVED BY WAUKEE CITY COUNCIL ON NOVEMBER 15, 2021 AMENDED BY THE WAUKEE CITY COUNCIL ON _______________2022 TABLE OF CONTENTS PETERSEN PROPERTY PLANNED DEVELOPMENT • Rezoning Request • Exhibit B – Waukee PD Form • Exhibit C – Property Legal Description • Exhibit D – Rezoning Map (2021) • Exhibit E – Rezoning Map Area B (2022) • Exhibit F – Conceptual Development Plan (2021) • Exhibit G – Conceptual Development Plan (2022) Exhibit B | PETERSEN PROPERTY – PLANNED DEVELOPMENT Waukee, Iowa Planned Development Overlay District (PD) Item 1 Purpose and Scope of District • The subject property is generally located south of NW Douglas Parkway and west of NW 10th Street. • The proposed Planned Development is an approximately 36.62-acre parcel of property. The proposed Planned Development calls for a small lot single family and townhome development. • The proposed underlying zoning of the Property will be R-2 (One & Two Family Residential District) (Area A) and R-4 (Row Dwelling and Townhome Dwelling District) (Area B) defining the allowable uses, bulk regulations and restrictions. Item 2 Location, Size, Legal Description • See Attached: Exhibit C – Property Legal Description Item 3 Conceptual Development Plan • See Attached: Exhibit D – Rezoning Map (2021) Exhibit E – Rezoning Map (2022) *Exhibit F – Conceptual Development Plan (2021) *Exhibit G – Conceptual Development Plan for Area B (2022) *Exhibit F represents a conceptual development plan showing proposed development of 90 attached townhome/rowhome units and 51 small lot single family lots. *Exhibit G represents a conceptual development plan for Area B which identifies the construction of a townhome development. Item 4 Building & Site Design Standards: Building design and site standards for the project shall be consistent with the Waukee Code of Ordinances as well as the additional design characteristics as follows: Area A: 1. Each single family home shall include a minimum of a two-car attached garage. 2. Each single family home shall require a minimum of 15% stone, brick or stucco on the front street facing elevation of the home. 3. Adjoining lots cannot consist of the same elevation. 4. Vinyl siding shall be permitted utilizing a 0.042-inch minimum thickness. Area B: 1. Each unit shall include a minimum of a two-car attached garage when facing a public street. A one-car attached garage shall be permitted when along a private street. All driveways shall be wide enough to accommodate two vehicles. Garage doors facing a public street shall not extend forward of the front façade line of the building. 2. Each building shall require a minimum of 20% stone, brick or stucco on the front street facing elevation of the home. Corners of building shall be wrapped with the same brick, stone, or stucco along public streets and at entrances into the development. 3. Adjoining buildings shall have a variation in architectural features or color. 4. Vinyl siding shall be permitted utilizing a 0.042-inch minimum thickness. A variety of siding that be implemented on the proposed units including, but not limited to board and batten, lap, and shake siding. 5. An outdoor space for each unit shall be provided. Item 5 Bulk Regulations – Including Density Regulations, Setbacks, Maximum Heights, and other design standards specific to the Project Area A: All lots and homes shall be consistent with the R-2 One & Two Family Residential District requirements with the following exceptions and modifications as specified below: 1. Overall Maximum Density: Five (5) Dwelling units per acre maximum. 2. Minimum Floor Area: 1,100 square feet for a single-story home. 1,400 square feet for a two-story home. 3. Front Yard: Thirty (30’) feet. 4. Rear Yard: Twenty-five (25’) feet. 5. Side Yard (Total Building Separation): Ten (10’) feet. 6. Lot Area: 5,500 square feet. 7. Lot Width: 50 feet. 8. Lots 37 – 44 shown on Exhibit E cannot b platted as buildable lots until the existing communications tower has been removed from the site. Area B: Attached Townhomes and Detached Townhomes All lots and homes shall be consistent with the R-4 Row Dwelling and Townhome Dwelling District requirements with the following exceptions and modifications as specified below: 1. Overall Maximum Density: Twelve (12) Dwelling Units/Acre maximum and consistent with the conceptual development plan as described in attached Exhibit E. 3. Front Yard: Thirty (30’) feet for buildings or units along public street right-of- way. For all other units with internal front yards, the minimum front yard setback shall be twenty-five (25’) feet from the back of the curb. 4. Side Yards (Total Building Separation): Twelve (12’) feet between units, Fifteen (15’) from private street back-of-curb, twenty (20’) feet for greater than 8 units. 5. Rear Yards: Thirty (30’) feet for buildings or units along public street right- of-way. For all other units with internal rear yards, the minimum rear yard setback shall be thirty (30’) feet between units. Item 6 Uses of Property – Including Principal Permitted Uses and Accessory Uses Area A: Only those uses and accessory uses only as permitted within the R-2 (One & Two Family Residential District) Zoning District. Area B: Those uses and accessory uses only as permitted within the R-4 (Row Dwelling and Townhome Dwelling) Zoning District with the following exceptions and modifications as specified below: 1. Detached townhomes, provided a homeowners association is responsible for property maintenance. Item 7 Park Land Dedication, Open Space, Landscape and Buffer Regulations Area A: 1. Parkland Dedication shall be provided as required within the City of Waukee Code of Ordinances. 2. Minimum open space and landscaping shall be as described within the City of Waukee Code of Ordinances. 3. Two (2) trees and two (2) shrubs shall be planted at the time of individual lot development. Area B: 1. Parkland Dedication shall be provided as required within the City of Waukee Code of Ordinances. 2. Minimum open space and landscaping shall be as described within the City of Waukee Code of Ordinances. 3. Landscape buffers shall be provided as required by the Landscape & Open Space Ordinance with the following exceptions: a. Landscape buffer shall not be required for townhomes abutting single family lots when fronting a public street or across the street from a single-family lot. END OF DOCUMENT EXHIBIT C LEGAL DESCRIPTION Area A A PART OF THE NORTHEAST QUARTER OF SECTION 29, TOWNSHIP 79 NORTH, RANGE 26 WEST OF THE FIFTH PRINCIPAL MERIDIAN IN THE CITY OF WAUKEE, DALLAS COUNTY, IOWA AND A PART OF PARCEL 'A' AS SHOWN ON THE PLAT OF SURVEY RECORDED IN BOOK 2003, PAGE 59 IN SAID NORTHEAST QUARTER AND ALL BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNING AT THE NORTHEAST CORNER OF LOT 32, STRATFORD CROSSING PLAT 7, AN OFFICIAL PLAT IN SAID CITY OF WAUKEE, SAID POINT ALSO BEING THE SOUTHWEST CORNER OF PARCEL 20-98 AS SHOWN ON THE PLAT OF SURVEY RECORDED IN BOOK 2021, PAGE 13204 IN SAID NORTHEAST QUARTER; THENCE NORTH 89°58'33" EAST ALONG THE SOUTHERLY LINE OF SAID PARCEL 20-98, A DISTANCE OF 748.48 FEET; THENCE SOUTH 00°01'35" EAST, 35.48 FEET; THENCE SOUTHERLY ALONG A CURVE CONCAVE EASTERLY WHOSE RADIUS IS 350.00 FEET, WHOSE ARC LENGTH IS 91.63 FEET AND WHOSE CHORD BEARS SOUTH 07°31'35" EAST, 91.37 FEET; THENCE SOUTH 15°01'35" EAST, 29.17 FEET; THENCE SOUTHERLY ALONG A CURVE CONCAVE WESTERLY WHOSE RADIUS IS 350.00 FEET, WHOSE ARC LENGTH IS 91.63 FEET AND WHOSE CHORD BEARS SOUTH 07°31'35" EAST, 91.37 FEET; THENCE SOUTH 00°01'35" EAST, 295.02 FEET; THENCE SOUTH 89°59'28" WEST, 131.19 FEET; THENCE SOUTH 00°00'32" EAST, 130.00 FEET; THENCE SOUTH 89°59'28" WEST, 200.00 FEET; THENCE NORTH 00°00'32" WEST, 130.00 FEET; THENCE SOUTH 89°59'28" WEST, 55.00 FEET; THENCE SOUTH 00°00'32" EAST, 130.00 FEET; THENCE SOUTH 89°59'28" WEST, 395.27 FEET TO THE EASTERLY LINE OF STRATFORD CROSSING PLAT 6, AN OFFICIAL PLAT IN SAID CITY OF WAUKEE; THENCE NORTH 00°06'44" EAST ALONG SAID EASTERLY LINE AND THE EASTERLY LINE OF SAID STRATFORD CROSSING PLAT 7, A DISTANCE OF, 669.64 FEET TO THE POINT OF BEGINNING AND CONTAINING 11.35 ACRES (494,250 SQUARE FEET). PROPERTY IS SUBJECT TO ANY AND ALL EASEMENTS OF RECORD. Area B A PART OF THE NORTHEAST QUARTER OF THE NORTHEAST QUARTER, AND A PART OF THE NORTHWEST QUARTER OF THE NORTHEAST QUARTER, AND A PART OF PARCEL ‘A’ OF SAID NORTHEAST QUARTER OF THE NORTHEAST QUARTER AS SHOWN ON THE PLAT OF SURVEY RECORDED IN BOOK 2003, PAGE 59, AND A PART OF TRACT “A” OF SAID NORTHEAST QUARTER OF THE NORTHEAST QUARTER AS SHOWN ON THE PLAT OF SURVEY RECORDED IN BOOK 2003, PAGE 58, ALL BEING IN SECTION 29, TOWNSHIP 79 NORTH, RANGE 26 WEST OF THE FIFTH PRINCIPAL MERIDIAN IN THE CITY OF WAUKEE, DALLAS COUNTY, IOWA AND MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNING AT THE SOUTHWEST CORNER OF SAID TRACT “A”; THENCE SOUTH 00°01'35" EAST ALONG THE WESTERLY LINE OF PARCEL “B” AND TRACT “B” AS SHOWN ON SAID PLAT OF SURVEY RECORDED IN BOOK 2003, PAGE 58, A DISTANCE OF 204.89 FEET TO THE SOUTH LINE OF SAID NORTHEAST QUARTER OF THE NORTHEAST QUARTER; THENCE SOUTH 89°57'31" WEST ALONG SAID SOUTH LINE AND THE SOUTH LINE OF SAID NORTHWEST QUARTER OF THE NORTHEAST QUARTER, 1072.93 FEET; THENCE NORTH 00°06'44" EAST, 585.87 FEET; THENCE NORTH 80°55'12" EAST, 70.76 FEET; THENCE NORTH 59°51'38" EAST, 56.32 FEET; THENCE NORTH 02°38'53" WEST, 128.97 FEET; THENCE NORTH 35°24'01" WEST, 30.00 FEET; THENCE NORTHEASTERLY ALONG A CURVE CONCAVE NORTHWESTERLY WHOSE RADIUS IS 150.00 FEET, WHOSE ARC LENGTH IS 68.42 FEET AND WHOSE CHORD BEARS NORTH 41°31'58" EAST, 67.83 FEET; THENCE SOUTH 61°32'03" EAST, 63.12 FEET; THENCE EASTERLY ALONG A CURVE CONCAVE NORTHERLY WHOSE RADIUS IS 400.00 FEET, WHOSE ARC LENGTH IS 198.79 FEET AND WHOSE CHORD BEARS SOUTH 75°46'18" EAST, 196.75 FEET; THENCE NORTH 89°59'28" EAST, 395.01 FEET; THENCE NORTH 00°01'35" WEST, 265.02 FEET; THENCE NORTHERLY ALONG A CURVE CONCAVE WESTERLY WHOSE RADIUS IS 350.00 FEET, WHOSE ARC LENGTH IS 91.63 FEET AND WHOSE CHORD BEARS NORTH 07°31'35" WEST, 91.37 FEET; THENCE NORTH 15°01'35" WEST, 29.17 FEET; THENCE NORTHERLY ALONG A CURVE CONCAVE EASTERLY WHOSE RADIUS IS 350.00 FEET, WHOSE ARC LENGTH IS 91.63 FEET AND WHOSE CHORD BEARS NORTH 07°31'35" WEST, 91.37 FEET; THENCE NORTH 00°01'35" WEST, 35.63 FEET TO THE SOUTHERLY LINE OF PARCEL 20-98 AS SHOWN ON THE PLAT OF SURVEY RECORDED IN BOOK 2021, PAGE 13204; THENCE NORTH 89°59'28" EAST ALONG SAID SOUTHERLY LINE, 17.21 FEET; THENCE SOUTH 89°27'05" EAST CONTINUING ALONG SAID SOUTHERLY LINE, 184.20 FEET; THENCE SOUTH 00°01'35" EAST, 330.62 FEET; THENCE NORTH 89°58'33" EAST, 65.05 FEET; THENCE SOUTH 00°00'32" EAST, 176.67 FEET; THENCE SOUTH 89°59'28" WEST, 5.00 FEET; THENCE SOUTH 00°01'34" EAST, 380.00 FEET; THENCE NORTH 89°59'28" EAST, 300.00 FEET TO THE WESTERLY RIGHT OF WAY LINE OF NW 10TH STREET; THENCE SOUTH 00°01'35" EAST ALONG SAID WESTERLY RIGHT OF WAY LINE, 146.72 FEET TO THE SOUTHERLY LINE OF SAID TRACT “A”; THENCE SOUTH 85°19'48" WEST ALONG SAID SOUTHERLY LINE, 240.79 FEET TO THE POINT OF BEGINNING AND CONTAINING 20.96 ACRES (912,826 SQUARE FEET). THE PROPERTY IS SUBJECT TO ANY AND ALL EASEMENTS OF RECORD. EXHIBIT D REZONING MAP (2021) EXHIBIT E Rezoning Map (2022) EXHIBIT F CONCEPTUAL DEVELOPMENT PLAN (2021) EXHIBIT G CONCEPTUAL DEVELOPMENT PLAN AREA B (2022) FIRST FLOOR 0" TRUSS BEARING 9' - 1 1/8" FIRST FLOOR 0" TRUSS BEARING 9' - 1 1/8" 3 " / 1 2 " 3 " / 1 2 " 3 " / 1 2 "3" / 12" 3" / 12" 3" / 12" 3" / 12" FIRST FLOOR 0" TRUSS BEARING 9' - 1 1/8" FIRST FLOOR 0" TRUSS BEARING 9' - 1 1/8" 3 " / 1 2 " 3 " / 1 2 " 3 " / 1 2 " 6 " / 1 2 "6" / 12" 3 " / 1 2 " 3" / 12" 3" / 12" 3" / 12" 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL CONDUIT RUNS & SERVICE LINES SHALL BE GROUPED TOGETHER IN A NEAT & ORDERLY MANNER AND SHOULD PENETRATE THE WALL AT THE LOWEST POINT AND ARE NOT TO RUN OVER THE TOP OF PARAPET. ALL OTHER CONDUITS & JUNCTION BOXES FOR EXTERIOR FIXTURES & EQUIPMENT SHALL BE FULLY CONCEALED WITHIN THE BUILDING CONSTRUCTION. 3. ALL HORIZONTAL TRANSITIONS BETWEEN DIFFERENT MATERIALS SHALL BE FLASHED CONTINUOUS FROM UP BEHIND UPPER MATERIAL AND EXTEND OVER TO EXTERIOR FACE OF LOWER MATERIAL WITH DRIP EDGE. 4. ANY RETURNS OR BLIND ELEVATIONS NOT SHOWN SHALL BE SIMILAR IN MATERIAL AND MAKEUP TO ADJACENT CONDITIONS OR OTHER SIMILAR CONDITIONS. 5. NO EXPOSED MASONRY/MATERIAL CORES. MASONRY RETURNS AT WINDOWS/OPENINGS ARE REQUIRED IF FRAMING IS NOT DEEP ENOUGH TO PROVIDE CLOSURE AT THE BACKSIDE OF MASONRY FOR AN EFFECTIVELY SEALED JOINT. 6. MATERIALS ABOVE CANOPIES & AWNINGS TO BE CONTINUED DOWN BEHIND THEM U.O.N., TYP. 7. ANY EXPOSED ROOFING MEMBRANE VISIBLE FROM A PUBLIC RIGHT AWAY MUST MATCH THE PRIMARY WALL MATERIAL COLOR. 8. INSTALL VERTICAL EXPANSION JOINTS PER STRUCTURAL OR MINIMAL AT COLUMN/GRID LINES AND AT THE HEAD OF DOOR JAMBS/OPENINGS OR AS OTHERWISE NOTED OR WHERE REQUIRED PER STANDARD MATERIAL PRACTICE TO REDUCE STRESS CRACKING. NO CONTROL JOINT/EXPANSION JOINT AT MAIN STRUCTURAL BEARING LOCATIONS. VERIFY JOINTS WITH ARCHITECT. 9. CAULK & SEAL ALL TRANSITION-CONTROL-EXPANSION AT ALL EXTERIOR MATERIALS. 10. PROVIDE CAST REGLETS JUST IN FROM THE OUTER EDGE ON UNDERSIDE OF FACE MATERIAL OR DRIP EDGE AT ALL OVERHANGS & SOFFITS. 11. INSULATE AND SEAL TO ENSURE ADEQUATE AIR INFILTRATION BARRIER AROUND ALL EXTERIOR PENETRATIONS TO PREVENT WATER AND SPRINKLER PIPE FREEZING. 12. WHERE EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF PAVING TO BE 1/4" LOWER THAN INTERIOR FINISH FLOOR, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. WHERE DOOR STOOP, 48" OUT FROM DOOR 1:48(2%) MAX. SLOPE, AFTER 48" AWAY FROM DOOR 1:20(5%) MAXIMUM SLOPE TO PUBLIC WAY. (REFER TO CIVIL) 13. WHERE NO EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF FINISHED LANDSCAPE A MINIMUM OF 4" BELOW INTERIOR FINISH FLOOR AND 4” BELOW EXTERIOR WALL FLASHING/WEEPS, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. (REFER TO CIVIL) 14. ADDRESS SHALL BE PROVIDED ON STREET SIDE OF BUILDING AND ON MONUMENT SIGN. NUMBERS A MINIMUM 5 INCH CONTRASTING COLOR NUMBERS WITH MINIMUM 1/2" STROKE. 15. IF ANY SIGNAGE OR SIGN BASE IS SHOWN IT IS FOR REFERENCE ONLY, FINAL DESIGNS AND/OR ALLOWANCES SHALL BE DETERMINED WITH APPROVED SIGNAGE PERMIT(S). ACTUAL DETAILS & DIMENSIONS MAY VARY AND ARE SUBJECT TO CHANGE. ALL DRAWINGS ARE SUBJECT TO AUTHORITY HAVING JURISDICTION APPROVAL. SIGNAGE SHOWN DOES NOT REPRESENT ALLOWABLE SIGNAGE PERMITTING/APPROVAL OF ALL SIGNAGE PER CURRENT CITY ORDINANCE BY OTHERS. GENERAL EXTERIOR ELEVATION NOTES Sheet No. Sheet Title Proj. No.Proj. Mgr. Th i s d r a w i n g h a s b e e n p r e p a r e d b y th e A r c h i t e c t , o r u n d e r t h e Ar c h i t e c t ' s d i r e c t s u p e r v i s i o n . T h i s dr a w i n g i s p r o v i d e d a s a n in s t r u m e n t o f s e r v i c e b y t h e De s i g n e r / A r c h i t e c t a n d i s i n t e n d e d fo r u s e o n t h i s p r o j e c t o n l y . A n y re p r o d u c t i o n , u s e , o r d i s c l o s u r e o f in f o r m a t i o n c o n t a i n e d h e r e i n wit h o u t t h e p r i o r w r i t t e n c o n s e n t o f th e A r c h i t e c t i s s t r i c t l y p r o h i b i t e d . (C ) C o p y r i g h t 2 0 2 2 b y S i m o n s o n & As s o c i a t e s A r c h i t e c t s , L . L . C . NO T F O R C O N S T R U C T I O N SAA C: \ U s e r s \ s p o o l e \ D o c u m e n t s \ 2 2 0 1 1 _ P e t e r s o n T o w n h o u s e s _3 - P l e x O n e - S t o r y T o w n h o u s e s _ s p o o l e P M D S N . r v t 6/ 8 / 2 0 2 2 7 : 0 4 : 0 2 P M PE T E R S O N T O W N H O U S E S U A V E N U E WA U K E E , I A 21113 A-201 DEEP RANCH EXTERIOR ELEVATIONS SCALE:3/16" = 1'-0"3 DEEP RANCH SIDE ELEVATION 2 SCALE:3/16" = 1'-0"2 DEEP RANCH REAR ELEVATION SCALE:3/16" = 1'-0"4 DEEP RANCH SIDE ELEVATION SCALE:3/16" = 1'-0"1 DEEP RANCH FRONT ELEVATION Rev. # Issue / Revision Date 5 Site Plan Submittal 06-09-2022 DE E P R A N C H ( 3 U N I T S ) EXTERIOR MATERIAL FINISHES ELEVATIONS SHOW SCHEMATIC COLORS AND TEXTURES OF INTENDED EXTERIOR MATERIAL FINISHES. MATERIALS TO CREATE THESE ELEVATIONS MAY INCLUDE A MIXTURE OF ANY OF THE FOLLOWING MATERIALS: • VINYL SIDING • FIBER CEMENT PANEL • FIBER CEMENT LAP • FIBER CEMENT BOARD & BATTEN • THIN BRICK OR STONE • METAL PANEL FIRST FLOOR 0" TRUSS BEARING 9' - 1 1/8" 3 " / 1 2 " 3 " / 1 2 " 3 " / 1 2 " 3" / 12"3 " / 1 2 " 3" / 12" 3" / 12" FIRST FLOOR 0" TRUSS BEARING 9' - 1 1/8" FIRST FLOOR 0" TRUSS BEARING 9' - 1 1/8" 3 " / 1 2 " 3 " / 1 2 " 3" / 12" 3" / 12" 3 " / 1 2 "3" / 12" 3" / 12" FIRST FLOOR 0" TRUSS BEARING 9' - 1 1/8" 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL CONDUIT RUNS & SERVICE LINES SHALL BE GROUPED TOGETHER IN A NEAT & ORDERLY MANNER AND SHOULD PENETRATE THE WALL AT THE LOWEST POINT AND ARE NOT TO RUN OVER THE TOP OF PARAPET. ALL OTHER CONDUITS & JUNCTION BOXES FOR EXTERIOR FIXTURES & EQUIPMENT SHALL BE FULLY CONCEALED WITHIN THE BUILDING CONSTRUCTION. 3. ALL HORIZONTAL TRANSITIONS BETWEEN DIFFERENT MATERIALS SHALL BE FLASHED CONTINUOUS FROM UP BEHIND UPPER MATERIAL AND EXTEND OVER TO EXTERIOR FACE OF LOWER MATERIAL WITH DRIP EDGE. 4. ANY RETURNS OR BLIND ELEVATIONS NOT SHOWN SHALL BE SIMILAR IN MATERIAL AND MAKEUP TO ADJACENT CONDITIONS OR OTHER SIMILAR CONDITIONS. 5. NO EXPOSED MASONRY/MATERIAL CORES. MASONRY RETURNS AT WINDOWS/OPENINGS ARE REQUIRED IF FRAMING IS NOT DEEP ENOUGH TO PROVIDE CLOSURE AT THE BACKSIDE OF MASONRY FOR AN EFFECTIVELY SEALED JOINT. 6. MATERIALS ABOVE CANOPIES & AWNINGS TO BE CONTINUED DOWN BEHIND THEM U.O.N., TYP. 7. ANY EXPOSED ROOFING MEMBRANE VISIBLE FROM A PUBLIC RIGHT AWAY MUST MATCH THE PRIMARY WALL MATERIAL COLOR. 8. INSTALL VERTICAL EXPANSION JOINTS PER STRUCTURAL OR MINIMAL AT COLUMN/GRID LINES AND AT THE HEAD OF DOOR JAMBS/OPENINGS OR AS OTHERWISE NOTED OR WHERE REQUIRED PER STANDARD MATERIAL PRACTICE TO REDUCE STRESS CRACKING. NO CONTROL JOINT/EXPANSION JOINT AT MAIN STRUCTURAL BEARING LOCATIONS. VERIFY JOINTS WITH ARCHITECT. 9. CAULK & SEAL ALL TRANSITION-CONTROL-EXPANSION AT ALL EXTERIOR MATERIALS. 10. PROVIDE CAST REGLETS JUST IN FROM THE OUTER EDGE ON UNDERSIDE OF FACE MATERIAL OR DRIP EDGE AT ALL OVERHANGS & SOFFITS. 11. INSULATE AND SEAL TO ENSURE ADEQUATE AIR INFILTRATION BARRIER AROUND ALL EXTERIOR PENETRATIONS TO PREVENT WATER AND SPRINKLER PIPE FREEZING. 12. WHERE EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF PAVING TO BE 1/4" LOWER THAN INTERIOR FINISH FLOOR, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. WHERE DOOR STOOP, 48" OUT FROM DOOR 1:48(2%) MAX. SLOPE, AFTER 48" AWAY FROM DOOR 1:20(5%) MAXIMUM SLOPE TO PUBLIC WAY. (REFER TO CIVIL) 13. WHERE NO EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF FINISHED LANDSCAPE A MINIMUM OF 4" BELOW INTERIOR FINISH FLOOR AND 4” BELOW EXTERIOR WALL FLASHING/WEEPS, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. (REFER TO CIVIL) 14. ADDRESS SHALL BE PROVIDED ON STREET SIDE OF BUILDING AND ON MONUMENT SIGN. NUMBERS A MINIMUM 5 INCH CONTRASTING COLOR NUMBERS WITH MINIMUM 1/2" STROKE. 15. IF ANY SIGNAGE OR SIGN BASE IS SHOWN IT IS FOR REFERENCE ONLY, FINAL DESIGNS AND/OR ALLOWANCES SHALL BE DETERMINED WITH APPROVED SIGNAGE PERMIT(S). ACTUAL DETAILS & DIMENSIONS MAY VARY AND ARE SUBJECT TO CHANGE. ALL DRAWINGS ARE SUBJECT TO AUTHORITY HAVING JURISDICTION APPROVAL. SIGNAGE SHOWN DOES NOT REPRESENT ALLOWABLE SIGNAGE PERMITTING/APPROVAL OF ALL SIGNAGE PER CURRENT CITY ORDINANCE BY OTHERS. GENERAL EXTERIOR ELEVATION NOTES Sheet No. Sheet Title Proj. No.Proj. Mgr. Th i s d r a w i n g h a s b e e n p r e p a r e d b y th e A r c h i t e c t , o r u n d e r t h e Ar c h i t e c t ' s d i r e c t s u p e r v i s i o n . T h i s dr a w i n g i s p r o v i d e d a s a n in s t r u m e n t o f s e r v i c e b y t h e De s i g n e r / A r c h i t e c t a n d i s i n t e n d e d fo r u s e o n t h i s p r o j e c t o n l y . A n y re p r o d u c t i o n , u s e , o r d i s c l o s u r e o f in f o r m a t i o n c o n t a i n e d h e r e i n wit h o u t t h e p r i o r w r i t t e n c o n s e n t o f th e A r c h i t e c t i s s t r i c t l y p r o h i b i t e d . (C ) C o p y r i g h t 2 0 2 2 b y S i m o n s o n & As s o c i a t e s A r c h i t e c t s , L . L . C . NO T F O R C O N S T R U C T I O N SAA C: \ U s e r s \ s p o o l e \ D o c u m e n t s \ 2 2 0 1 1 _ P e t e r s o n T o w n h o u s e s _3 - P l e x O n e - S t o r y T o w n h o u s e s _ W a l n u t & B i r c h _ s p o o l e P M D SN . r v t 6/ 8 / 2 0 2 2 7 : 0 2 : 4 4 P M PE T E R S O N T O W N H O U S E S U A V E N U E WA U K E E , I O W A 22011 A-201 WALNUT EXTERIOR ELEVATIONS SCALE:3/16" = 1'-0"1 WALNUT FRONT ELEVATION SCALE:3/16" = 1'-0"4 WALNUT SIDE ELEVATION 2 SCALE:3/16" = 1'-0"2 WALNUT REAR ELEVATION SCALE:3/16" = 1'-0"3 WALNUT SIDE ELEVATION Rev. # Issue / Revision Date 5 Site Plan Submittal 06-09-2022 WA L N U T ( 3 U N I T S ) EXTERIOR MATERIAL FINISHES ELEVATIONS SHOW SCHEMATIC COLORS AND TEXTURES OF INTENDED EXTERIOR MATERIAL FINISHES. MATERIALS TO CREATE THESE ELEVATIONS MAY INCLUDE A MIXTURE OF ANY OF THE FOLLOWING MATERIALS: • VINYL SIDING • FIBER CEMENT PANEL • FIBER CEMENT LAP • FIBER CEMENT BOARD & BATTEN • THIN BRICK OR STONE • METAL PANEL FIRST FLOOR 0" TRUSS BEARING 9' - 1 1/8" 3 " / 1 2 "3" / 12" FIRST FLOOR 0" TRUSS BEARING 9' - 1 1/8" FIRST FLOOR 0" TRUSS BEARING 9' - 1 1/8" FIRST FLOOR 0" TRUSS BEARING 9' - 1 1/8" 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL CONDUIT RUNS & SERVICE LINES SHALL BE GROUPED TOGETHER IN A NEAT & ORDERLY MANNER AND SHOULD PENETRATE THE WALL AT THE LOWEST POINT AND ARE NOT TO RUN OVER THE TOP OF PARAPET. ALL OTHER CONDUITS & JUNCTION BOXES FOR EXTERIOR FIXTURES & EQUIPMENT SHALL BE FULLY CONCEALED WITHIN THE BUILDING CONSTRUCTION. 3. ALL HORIZONTAL TRANSITIONS BETWEEN DIFFERENT MATERIALS SHALL BE FLASHED CONTINUOUS FROM UP BEHIND UPPER MATERIAL AND EXTEND OVER TO EXTERIOR FACE OF LOWER MATERIAL WITH DRIP EDGE. 4. ANY RETURNS OR BLIND ELEVATIONS NOT SHOWN SHALL BE SIMILAR IN MATERIAL AND MAKEUP TO ADJACENT CONDITIONS OR OTHER SIMILAR CONDITIONS. 5. NO EXPOSED MASONRY/MATERIAL CORES. MASONRY RETURNS AT WINDOWS/OPENINGS ARE REQUIRED IF FRAMING IS NOT DEEP ENOUGH TO PROVIDE CLOSURE AT THE BACKSIDE OF MASONRY FOR AN EFFECTIVELY SEALED JOINT. 6. MATERIALS ABOVE CANOPIES & AWNINGS TO BE CONTINUED DOWN BEHIND THEM U.O.N., TYP. 7. ANY EXPOSED ROOFING MEMBRANE VISIBLE FROM A PUBLIC RIGHT AWAY MUST MATCH THE PRIMARY WALL MATERIAL COLOR. 8. INSTALL VERTICAL EXPANSION JOINTS PER STRUCTURAL OR MINIMAL AT COLUMN/GRID LINES AND AT THE HEAD OF DOOR JAMBS/OPENINGS OR AS OTHERWISE NOTED OR WHERE REQUIRED PER STANDARD MATERIAL PRACTICE TO REDUCE STRESS CRACKING. NO CONTROL JOINT/EXPANSION JOINT AT MAIN STRUCTURAL BEARING LOCATIONS. VERIFY JOINTS WITH ARCHITECT. 9. CAULK & SEAL ALL TRANSITION-CONTROL-EXPANSION AT ALL EXTERIOR MATERIALS. 10. PROVIDE CAST REGLETS JUST IN FROM THE OUTER EDGE ON UNDERSIDE OF FACE MATERIAL OR DRIP EDGE AT ALL OVERHANGS & SOFFITS. 11. INSULATE AND SEAL TO ENSURE ADEQUATE AIR INFILTRATION BARRIER AROUND ALL EXTERIOR PENETRATIONS TO PREVENT WATER AND SPRINKLER PIPE FREEZING. 12. WHERE EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF PAVING TO BE 1/4" LOWER THAN INTERIOR FINISH FLOOR, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. WHERE DOOR STOOP, 48" OUT FROM DOOR 1:48(2%) MAX. SLOPE, AFTER 48" AWAY FROM DOOR 1:20(5%) MAXIMUM SLOPE TO PUBLIC WAY. (REFER TO CIVIL) 13. WHERE NO EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF FINISHED LANDSCAPE A MINIMUM OF 4" BELOW INTERIOR FINISH FLOOR AND 4” BELOW EXTERIOR WALL FLASHING/WEEPS, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. (REFER TO CIVIL) 14. ADDRESS SHALL BE PROVIDED ON STREET SIDE OF BUILDING AND ON MONUMENT SIGN. NUMBERS A MINIMUM 5 INCH CONTRASTING COLOR NUMBERS WITH MINIMUM 1/2" STROKE. 15. IF ANY SIGNAGE OR SIGN BASE IS SHOWN IT IS FOR REFERENCE ONLY, FINAL DESIGNS AND/OR ALLOWANCES SHALL BE DETERMINED WITH APPROVED SIGNAGE PERMIT(S). ACTUAL DETAILS & DIMENSIONS MAY VARY AND ARE SUBJECT TO CHANGE. ALL DRAWINGS ARE SUBJECT TO AUTHORITY HAVING JURISDICTION APPROVAL. SIGNAGE SHOWN DOES NOT REPRESENT ALLOWABLE SIGNAGE PERMITTING/APPROVAL OF ALL SIGNAGE PER CURRENT CITY ORDINANCE BY OTHERS. GENERAL EXTERIOR ELEVATION NOTES Sheet No. Sheet Title Proj. No.Proj. Mgr. Th i s d r a w i n g h a s b e e n p r e p a r e d b y th e A r c h i t e c t , o r u n d e r t h e Ar c h i t e c t ' s d i r e c t s u p e r v i s i o n . T h i s dr a w i n g i s p r o v i d e d a s a n in s t r u m e n t o f s e r v i c e b y t h e De s i g n e r / A r c h i t e c t a n d i s i n t e n d e d fo r u s e o n t h i s p r o j e c t o n l y . A n y re p r o d u c t i o n , u s e , o r d i s c l o s u r e o f in f o r m a t i o n c o n t a i n e d h e r e i n wit h o u t t h e p r i o r w r i t t e n c o n s e n t o f th e A r c h i t e c t i s s t r i c t l y p r o h i b i t e d . (C ) C o p y r i g h t 2 0 2 2 b y S i m o n s o n & As s o c i a t e s A r c h i t e c t s , L . L . C . NO T F O R C O N S T R U C T I O N SAA C: \ U s e r s \ s p o o l e \ D o c u m e n t s \ 2 2 0 1 1 _ P e t e r s o n T o w n h o u s e s _3 - P l e x O n e - S t o r y T o w n h o u s e s _ W a l n u t & B i r c h _ s p o o l e P M D SN . r v t 6/ 8 / 2 0 2 2 7 : 0 2 : 4 9 P M PE T E R S O N T O W N H O U S E S U A V E N U E WA U K E E , I O W A 22011 A-202 BIRCH EXTERIOR ELEVATIONS SCALE:3/16" = 1'-0"1 BIRCH FRONT ELEVATION SCALE:3/16" = 1'-0"2 BIRCH REAR ELEVATION SCALE:3/16" = 1'-0"3 BIRCH SIDE ELEVATION SCALE:3/16" = 1'-0"4 BIRCH SIDE ELEVATION 2 Rev. # Issue / Revision Date 5 Site Plan Submittal 06-09-2022 BI R C H ( 3 U N I T S ) EXTERIOR MATERIAL FINISHES ELEVATIONS SHOW SCHEMATIC COLORS AND TEXTURES OF INTENDED EXTERIOR MATERIAL FINISHES. MATERIALS TO CREATE THESE ELEVATIONS MAY INCLUDE A MIXTURE OF ANY OF THE FOLLOWING MATERIALS: • VINYL SIDING • FIBER CEMENT PANEL • FIBER CEMENT LAP • FIBER CEMENT BOARD & BATTEN • METAL PANEL LEVEL 1 100' - 0" LEVEL 2 110' - 7 7/8" TRUSS BEARING 119' - 9" 3 " / 1 2 " 3" / 12" 3 " / 1 2 " 3" / 12" 3 " / 1 2 " 3" / 12" 3" / 12" 3 " / 1 2 "1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL CONDUIT RUNS & SERVICE LINES SHALL BE GROUPED TOGETHER IN A NEAT & ORDERLY MANNER AND SHOULD PENETRATE THE WALL AT THE LOWEST POINT AND ARE NOT TO RUN OVER THE TOP OF PARAPET. ALL OTHER CONDUITS & JUNCTION BOXES FOR EXTERIOR FIXTURES & EQUIPMENT SHALL BE FULLY CONCEALED WITHIN THE BUILDING CONSTRUCTION. 3. ALL HORIZONTAL TRANSITIONS BETWEEN DIFFERENT MATERIALS SHALL BE FLASHED CONTINUOUS FROM UP BEHIND UPPER MATERIAL AND EXTEND OVER TO EXTERIOR FACE OF LOWER MATERIAL WITH DRIP EDGE. 4. ANY RETURNS OR BLIND ELEVATIONS NOT SHOWN SHALL BE SIMILAR IN MATERIAL AND MAKEUP TO ADJACENT CONDITIONS OR OTHER SIMILAR CONDITIONS. 5. NO EXPOSED MASONRY/MATERIAL CORES. MASONRY RETURNS AT WINDOWS/OPENINGS ARE REQUIRED IF FRAMING IS NOT DEEP ENOUGH TO PROVIDE CLOSURE AT THE BACKSIDE OF MASONRY FOR AN EFFECTIVELY SEALED JOINT. 6. MATERIALS ABOVE CANOPIES & AWNINGS TO BE CONTINUED DOWN BEHIND THEM U.O.N., TYP. 7. ANY EXPOSED ROOFING MEMBRANE VISIBLE FROM A PUBLIC RIGHT AWAY MUST MATCH THE PRIMARY WALL MATERIAL COLOR. 8. INSTALL VERTICAL EXPANSION JOINTS PER STRUCTURAL OR MINIMAL AT COLUMN/GRID LINES AND AT THE HEAD OF DOOR JAMBS/OPENINGS OR AS OTHERWISE NOTED OR WHERE REQUIRED PER STANDARD MATERIAL PRACTICE TO REDUCE STRESS CRACKING. NO CONTROL JOINT/EXPANSION JOINT AT MAIN STRUCTURAL BEARING LOCATIONS. VERIFY JOINTS WITH ARCHITECT. 9. CAULK & SEAL ALL TRANSITION-CONTROL-EXPANSION AT ALL EXTERIOR MATERIALS. 10. PROVIDE CAST REGLETS JUST IN FROM THE OUTER EDGE ON UNDERSIDE OF FACE MATERIAL OR DRIP EDGE AT ALL OVERHANGS & SOFFITS. 11. INSULATE AND SEAL TO ENSURE ADEQUATE AIR INFILTRATION BARRIER AROUND ALL EXTERIOR PENETRATIONS TO PREVENT WATER AND SPRINKLER PIPE FREEZING. 12. WHERE EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF PAVING TO BE 1/4" LOWER THAN INTERIOR FINISH FLOOR, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. WHERE DOOR STOOP, 48" OUT FROM DOOR 1:48(2%) MAX. SLOPE, AFTER 48" AWAY FROM DOOR 1:20(5%) MAXIMUM SLOPE TO PUBLIC WAY. (REFER TO CIVIL) 13. WHERE NO EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF FINISHED LANDSCAPE A MINIMUM OF 4" BELOW INTERIOR FINISH FLOOR AND 4” BELOW EXTERIOR WALL FLASHING/WEEPS, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. (REFER TO CIVIL) 14. ADDRESS SHALL BE PROVIDED ON STREET SIDE OF BUILDING AND ON MONUMENT SIGN. NUMBERS A MINIMUM 5 INCH CONTRASTING COLOR NUMBERS WITH MINIMUM 1/2" STROKE. 15. IF ANY SIGNAGE OR SIGN BASE IS SHOWN IT IS FOR REFERENCE ONLY, FINAL DESIGNS AND/OR ALLOWANCES SHALL BE DETERMINED WITH APPROVED SIGNAGE PERMIT(S). ACTUAL DETAILS & DIMENSIONS MAY VARY AND ARE SUBJECT TO CHANGE. ALL DRAWINGS ARE SUBJECT TO AUTHORITY HAVING JURISDICTION APPROVAL. SIGNAGE SHOWN DOES NOT REPRESENT ALLOWABLE SIGNAGE PERMITTING/APPROVAL OF ALL SIGNAGE PER CURRENT CITY ORDINANCE BY OTHERS. GENERAL EXTERIOR ELEVATION NOTES LEVEL 1 100' - 0" LEVEL 2 110' - 7 7/8" TRUSS BEARING 119' - 9" 3 " / 1 2 " 3" / 12" 3 " / 1 2 " 3" / 12"3 " / 1 2 " 3" / 12" 3 " / 1 2 " 3" / 12" LEVEL 1 100' - 0" LEVEL 2 110' - 7 7/8" TRUSS BEARING 119' - 9" LEVEL 1 100' - 0" LEVEL 2 110' - 7 7/8" TRUSS BEARING 119' - 9" Sheet No. Sheet Title Proj. No.Proj. Mgr. Th i s d r a w i n g h a s b e e n p r e p a r e d b y th e A r c h i t e c t , o r u n d e r t h e Ar c h i t e c t ' s d i r e c t s u p e r v i s i o n . T h i s dr a w i n g i s p r o v i d e d a s a n in s t r u m e n t o f s e r v i c e b y t h e De s i g n e r / A r c h i t e c t a n d i s i n t e n d e d fo r u s e o n t h i s p r o j e c t o n l y . A n y re p r o d u c t i o n , u s e , o r d i s c l o s u r e o f in f o r m a t i o n c o n t a i n e d h e r e i n wit h o u t t h e p r i o r w r i t t e n c o n s e n t o f th e A r c h i t e c t i s s t r i c t l y p r o h i b i t e d . (C ) C o p y r i g h t 2 0 2 2 b y S i m o n s o n & As s o c i a t e s A r c h i t e c t s , L . L . C . NO T F O R C O N S T R U C T I O N SAA J: \ 2 0 2 2 \ 2 2 0 1 1 U A v e n u e - S i n g l e F a m i l y R e n t a l s , W a u ke e , I A \ C A D - A r c h \ 2 2 0 1 1 _ P e t e r s o n T o w n h o u s e s _ 4 - P l e x T wo - S t o r y O n e C a r G a r a g e . r v t 6/ 8 / 2 0 2 2 7 : 0 1 : 1 8 P M PE T E R S O N T O W N H O U S E S U A V E N U E WA U K E E , I O W A 22011 A-201 EXTERIOR ELEVATIONS SP SCALE:3/16" = 1'-0"1 FRONT ELEVATION SCALE:3/16" = 1'-0"2 REAR ELEVATION SCALE:3/16" = 1'-0"3 SIDE ELEVATION 1 SCALE:3/16" = 1'-0"4 SIDE ELEVATION 2 Rev. # Issue / Revision Date 1 Site Plan Submittal 06-09-2022 RO O F T O P ( 4 U N I T S ) EXTERIOR MATERIAL FINISHES ELEVATIONS SHOW SCHEMATIC COLORS AND TEXTURES OF INTENDED EXTERIOR MATERIAL FINISHES. MATERIALS TO CREATE THESE ELEVATIONS MAY INCLUDE A MIXTURE OF ANY OF THE FOLLOWING MATERIALS: • VINYL SIDING • FIBER CEMENT PANEL • FIBER CEMENT LAP • FIBER CEMENT BOARD & BATTEN • THIN BRICK OR STONE • METAL PANEL FIRST FLOOR 100' - 0" SECOND FLOOR 110' - 7 7/8" TRUSS BEARING 119' - 9" 4 " / 1 2 " 4 " / 1 2 "4" / 12" FIRST FLOOR 100' - 0" SECOND FLOOR 110' - 7 7/8" TRUSS BEARING 119' - 9" FIRST FLOOR 100' - 0" SECOND FLOOR 110' - 7 7/8" TRUSS BEARING 119' - 9" C000 4 " / 1 2 " 4" / 12" 4" / 12" FIRST FLOOR 100' - 0" SECOND FLOOR 110' - 7 7/8" TRUSS BEARING 119' - 9" 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL CONDUIT RUNS & SERVICE LINES SHALL BE GROUPED TOGETHER IN A NEAT & ORDERLY MANNER AND SHOULD PENETRATE THE WALL AT THE LOWEST POINT AND ARE NOT TO RUN OVER THE TOP OF PARAPET. ALL OTHER CONDUITS & JUNCTION BOXES FOR EXTERIOR FIXTURES & EQUIPMENT SHALL BE FULLY CONCEALED WITHIN THE BUILDING CONSTRUCTION. 3. ALL HORIZONTAL TRANSITIONS BETWEEN DIFFERENT MATERIALS SHALL BE FLASHED CONTINUOUS FROM UP BEHIND UPPER MATERIAL AND EXTEND OVER TO EXTERIOR FACE OF LOWER MATERIAL WITH DRIP EDGE. 4. ANY RETURNS OR BLIND ELEVATIONS NOT SHOWN SHALL BE SIMILAR IN MATERIAL AND MAKEUP TO ADJACENT CONDITIONS OR OTHER SIMILAR CONDITIONS. 5. NO EXPOSED MASONRY/MATERIAL CORES. MASONRY RETURNS AT WINDOWS/OPENINGS ARE REQUIRED IF FRAMING IS NOT DEEP ENOUGH TO PROVIDE CLOSURE AT THE BACKSIDE OF MASONRY FOR AN EFFECTIVELY SEALED JOINT. 6. MATERIALS ABOVE CANOPIES & AWNINGS TO BE CONTINUED DOWN BEHIND THEM U.O.N., TYP. 7. ANY EXPOSED ROOFING MEMBRANE VISIBLE FROM A PUBLIC RIGHT AWAY MUST MATCH THE PRIMARY WALL MATERIAL COLOR. 8. INSTALL VERTICAL EXPANSION JOINTS PER STRUCTURAL OR MINIMAL AT COLUMN/GRID LINES AND AT THE HEAD OF DOOR JAMBS/OPENINGS OR AS OTHERWISE NOTED OR WHERE REQUIRED PER STANDARD MATERIAL PRACTICE TO REDUCE STRESS CRACKING. NO CONTROL JOINT/EXPANSION JOINT AT MAIN STRUCTURAL BEARING LOCATIONS. VERIFY JOINTS WITH ARCHITECT. 9. CAULK & SEAL ALL TRANSITION-CONTROL-EXPANSION AT ALL EXTERIOR MATERIALS. 10. PROVIDE CAST REGLETS JUST IN FROM THE OUTER EDGE ON UNDERSIDE OF FACE MATERIAL OR DRIP EDGE AT ALL OVERHANGS & SOFFITS. 11. INSULATE AND SEAL TO ENSURE ADEQUATE AIR INFILTRATION BARRIER AROUND ALL EXTERIOR PENETRATIONS TO PREVENT WATER AND SPRINKLER PIPE FREEZING. 12. WHERE EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF PAVING TO BE 1/4" LOWER THAN INTERIOR FINISH FLOOR, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. WHERE DOOR STOOP, 48" OUT FROM DOOR 1:48(2%) MAX. SLOPE, AFTER 48" AWAY FROM DOOR 1:20(5%) MAXIMUM SLOPE TO PUBLIC WAY. (REFER TO CIVIL) 13. WHERE NO EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF FINISHED LANDSCAPE A MINIMUM OF 4" BELOW INTERIOR FINISH FLOOR AND 4” BELOW EXTERIOR WALL FLASHING/WEEPS, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. (REFER TO CIVIL) 14. ADDRESS SHALL BE PROVIDED ON STREET SIDE OF BUILDING AND ON MONUMENT SIGN. NUMBERS A MINIMUM 5 INCH CONTRASTING COLOR NUMBERS WITH MINIMUM 1/2" STROKE. 15. IF ANY SIGNAGE OR SIGN BASE IS SHOWN IT IS FOR REFERENCE ONLY, FINAL DESIGNS AND/OR ALLOWANCES SHALL BE DETERMINED WITH APPROVED SIGNAGE PERMIT(S). ACTUAL DETAILS & DIMENSIONS MAY VARY AND ARE SUBJECT TO CHANGE. ALL DRAWINGS ARE SUBJECT TO AUTHORITY HAVING JURISDICTION APPROVAL. SIGNAGE SHOWN DOES NOT REPRESENT ALLOWABLE SIGNAGE PERMITTING/APPROVAL OF ALL SIGNAGE PER CURRENT CITY ORDINANCE BY OTHERS. GENERAL EXTERIOR ELEVATION NOTES Sheet No. Sheet Title Proj. No.Proj. Mgr. Th i s d r a w i n g h a s b e e n p r e p a r e d b y th e A r c h i t e c t , o r u n d e r t h e Ar c h i t e c t ' s d i r e c t s u p e r v i s i o n . T h i s dr a w i n g i s p r o v i d e d a s a n in s t r u m e n t o f s e r v i c e b y t h e De s i g n e r / A r c h i t e c t a n d i s i n t e n d e d fo r u s e o n t h i s p r o j e c t o n l y . A n y re p r o d u c t i o n , u s e , o r d i s c l o s u r e o f in f o r m a t i o n c o n t a i n e d h e r e i n wit h o u t t h e p r i o r w r i t t e n c o n s e n t o f th e A r c h i t e c t i s s t r i c t l y p r o h i b i t e d . (C ) C o p y r i g h t 2 0 2 2 b y S i m o n s o n & As s o c i a t e s A r c h i t e c t s , L . L . C . SAA C: \ U s e r s \ s p o o l e \ D o c u m e n t s \ 2 2 0 1 1 _ P e t e r s o n T o w n h o u s e s _4 - P l e x T w o - S t o r y T w o C a r G a r a g e _ C a r b o n _ s p o o l e P M D S N .r v t 6/ 8 / 2 0 2 2 7 : 0 5 : 1 7 P M PE T E R S O N T O W N H O U S E S U A V E N U E WA U K E E , I O W A 22011 A-201 CARBON 4-PLEX EXTERIOR ELEVATIONS SCALE:3/16" = 1'-0"1 CARBON (4-PLEX) FRONT ELEVATION SCALE:3/16" = 1'-0"3 CARBON (4-PLEX) SIDE ELEVATION SCALE:3/16" = 1'-0"2 CARBON (4-PLEX) REAR ELEVATION SCALE:3/16" = 1'-0"4 CARBON (4-PLEX) SIDE ELEVATION 2 Rev. # Issue / Revision Date 9 Site Plan Submittal 06-09-2022 CA R B O N ( 4 U N I T S ) EXTERIOR MATERIAL FINISHES ELEVATIONS SHOW SCHEMATIC COLORS AND TEXTURES OF INTENDED EXTERIOR MATERIAL FINISHES. MATERIALS TO CREATE THESE ELEVATIONS MAY INCLUDE A MIXTURE OF ANY OF THE FOLLOWING MATERIALS: • VINYL SIDING • FIBER CEMENT PANEL • FIBER CEMENT LAP • FIBER CEMENT BOARD & BATTEN • THIN BRICK OR STONE • METAL PANEL LEVEL 1 100' - 0" LEVEL 1 100' - 0" LEVEL 2 110' - 7 7/8" LEVEL 2 110' - 7 7/8" TRUSS BEARING 119' - 9" TRUSS BEARING 119' - 9" 4 " / 1 2 " 4 " / 1 2 "4" / 12" 4 " / 1 2 " 4" / 12" 2" / 12" 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL CONDUIT RUNS & SERVICE LINES SHALL BE GROUPED TOGETHER IN A NEAT & ORDERLY MANNER AND SHOULD PENETRATE THE WALL AT THE LOWEST POINT AND ARE NOT TO RUN OVER THE TOP OF PARAPET. ALL OTHER CONDUITS & JUNCTION BOXES FOR EXTERIOR FIXTURES & EQUIPMENT SHALL BE FULLY CONCEALED WITHIN THE BUILDING CONSTRUCTION. 3. ALL HORIZONTAL TRANSITIONS BETWEEN DIFFERENT MATERIALS SHALL BE FLASHED CONTINUOUS FROM UP BEHIND UPPER MATERIAL AND EXTEND OVER TO EXTERIOR FACE OF LOWER MATERIAL WITH DRIP EDGE. 4. ANY RETURNS OR BLIND ELEVATIONS NOT SHOWN SHALL BE SIMILAR IN MATERIAL AND MAKEUP TO ADJACENT CONDITIONS OR OTHER SIMILAR CONDITIONS. 5. NO EXPOSED MASONRY/MATERIAL CORES. MASONRY RETURNS AT WINDOWS/OPENINGS ARE REQUIRED IF FRAMING IS NOT DEEP ENOUGH TO PROVIDE CLOSURE AT THE BACKSIDE OF MASONRY FOR AN EFFECTIVELY SEALED JOINT. 6. MATERIALS ABOVE CANOPIES & AWNINGS TO BE CONTINUED DOWN BEHIND THEM U.O.N., TYP. 7. ANY EXPOSED ROOFING MEMBRANE VISIBLE FROM A PUBLIC RIGHT AWAY MUST MATCH THE PRIMARY WALL MATERIAL COLOR. 8. INSTALL VERTICAL EXPANSION JOINTS PER STRUCTURAL OR MINIMAL AT COLUMN/GRID LINES AND AT THE HEAD OF DOOR JAMBS/OPENINGS OR AS OTHERWISE NOTED OR WHERE REQUIRED PER STANDARD MATERIAL PRACTICE TO REDUCE STRESS CRACKING. NO CONTROL JOINT/EXPANSION JOINT AT MAIN STRUCTURAL BEARING LOCATIONS. VERIFY JOINTS WITH ARCHITECT. 9. CAULK & SEAL ALL TRANSITION-CONTROL-EXPANSION AT ALL EXTERIOR MATERIALS. 10. PROVIDE CAST REGLETS JUST IN FROM THE OUTER EDGE ON UNDERSIDE OF FACE MATERIAL OR DRIP EDGE AT ALL OVERHANGS & SOFFITS. 11. INSULATE AND SEAL TO ENSURE ADEQUATE AIR INFILTRATION BARRIER AROUND ALL EXTERIOR PENETRATIONS TO PREVENT WATER AND SPRINKLER PIPE FREEZING. 12. WHERE EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF PAVING TO BE 1/4" LOWER THAN INTERIOR FINISH FLOOR, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. WHERE DOOR STOOP, 48" OUT FROM DOOR 1:48(2%) MAX. SLOPE, AFTER 48" AWAY FROM DOOR 1:20(5%) MAXIMUM SLOPE TO PUBLIC WAY. (REFER TO CIVIL) 13. WHERE NO EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF FINISHED LANDSCAPE A MINIMUM OF 4" BELOW INTERIOR FINISH FLOOR AND 4” BELOW EXTERIOR WALL FLASHING/WEEPS, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. (REFER TO CIVIL) 14. ADDRESS SHALL BE PROVIDED ON STREET SIDE OF BUILDING AND ON MONUMENT SIGN. NUMBERS A MINIMUM 5 INCH CONTRASTING COLOR NUMBERS WITH MINIMUM 1/2" STROKE. 15. IF ANY SIGNAGE OR SIGN BASE IS SHOWN IT IS FOR REFERENCE ONLY, FINAL DESIGNS AND/OR ALLOWANCES SHALL BE DETERMINED WITH APPROVED SIGNAGE PERMIT(S). ACTUAL DETAILS & DIMENSIONS MAY VARY AND ARE SUBJECT TO CHANGE. ALL DRAWINGS ARE SUBJECT TO AUTHORITY HAVING JURISDICTION APPROVAL. SIGNAGE SHOWN DOES NOT REPRESENT ALLOWABLE SIGNAGE PERMITTING/APPROVAL OF ALL SIGNAGE PER CURRENT CITY ORDINANCE BY OTHERS. GENERAL EXTERIOR ELEVATION NOTES LEVEL 1 100' - 0" LEVEL 1 100' - 0" LEVEL 2 110' - 7 7/8" LEVEL 2 110' - 7 7/8" TRUSS BEARING 119' - 9" TRUSS BEARING 119' - 9" 4 " / 1 2 "4" / 12" LEVEL 1 100' - 0" LEVEL 2 110' - 7 7/8" TRUSS BEARING 119' - 9" LEVEL 1 100' - 0" LEVEL 2 110' - 7 7/8" TRUSS BEARING 119' - 9" Sheet No. Sheet Title Proj. No.Proj. Mgr. Th i s d r a w i n g h a s b e e n p r e p a r e d b y th e A r c h i t e c t , o r u n d e r t h e Ar c h i t e c t ' s d i r e c t s u p e r v i s i o n . T h i s dr a w i n g i s p r o v i d e d a s a n in s t r u m e n t o f s e r v i c e b y t h e De s i g n e r / A r c h i t e c t a n d i s i n t e n d e d fo r u s e o n t h i s p r o j e c t o n l y . A n y re p r o d u c t i o n , u s e , o r d i s c l o s u r e o f in f o r m a t i o n c o n t a i n e d h e r e i n wit h o u t t h e p r i o r w r i t t e n c o n s e n t o f th e A r c h i t e c t i s s t r i c t l y p r o h i b i t e d . (C ) C o p y r i g h t 2 0 2 2 b y S i m o n s o n & As s o c i a t e s A r c h i t e c t s , L . L . C . NO T F O R C O N S T R U C T I O N SAA J: \ 2 0 2 2 \ 2 2 0 1 1 U A v e n u e - S i n g l e F a m i l y R e n t a l s , W a u ke e , I A \ C A D - A r c h \ 2 2 0 1 1 _ P e t e r s o n T o w n h o u s e s _ 4 - P l e x T wo - S t o r y T w o C a r G a r a g e . r v t 6/ 8 / 2 0 2 2 7 : 0 0 : 0 4 P M PE T E R S O N T O W N H O U S E S U A V E N U E WA U K E E , I O W A 22011 A-201 EXTERIOR ELEVATIONS SP SCALE:3/16" = 1'-0"1 REAR ELEVATION SCALE:3/16" = 1'-0"2 FRONT ELEVATION SCALE:3/16" = 1'-0"3 SIDE ELEVATION 1 SCALE:3/16" = 1'-0"4 SIDE ELEVATION 2 RO C K W E L L ( 4 U N I T S ) Rev. # Issue / Revision Date 1 Site Plan Submittal 06-09-2022 EXTERIOR MATERIAL FINISHES ELEVATIONS SHOW SCHEMATIC COLORS AND TEXTURES OF INTENDED EXTERIOR MATERIAL FINISHES. MATERIALS TO CREATE THESE ELEVATIONS MAY INCLUDE A MIXTURE OF ANY OF THE FOLLOWING MATERIALS: • VINYL SIDING • FIBER CEMENT PANEL • FIBER CEMENT LAP • FIBER CEMENT BOARD & BATTEN • THIN BRICK OR STONE • METAL PANEL FINISHED FLOOR 0" TRUSS BEARING 10' - 1 1/8" FINISHED FLOOR 0" TRUSS BEARING 10' - 1 1/8" FINISHED FLOOR 0" TRUSS BEARING 10' - 1 1/8" FINISHED FLOOR 0" TRUSS BEARING 10' - 1 1/8" Sheet No. Sheet Title Proj. No.Proj. Mgr. Th i s d r a w i n g h a s b e e n p r e p a r e d b y th e A r c h i t e c t , o r u n d e r t h e Ar c h i t e c t ' s d i r e c t s u p e r v i s i o n . T h i s dr a w i n g i s p r o v i d e d a s a n in s t r u m e n t o f s e r v i c e b y t h e De s i g n e r / A r c h i t e c t a n d i s i n t e n d e d fo r u s e o n t h i s p r o j e c t o n l y . A n y re p r o d u c t i o n , u s e , o r d i s c l o s u r e o f in f o r m a t i o n c o n t a i n e d h e r e i n wit h o u t t h e p r i o r w r i t t e n c o n s e n t o f th e A r c h i t e c t i s s t r i c t l y p r o h i b i t e d . (C ) C o p y r i g h t 2 0 2 2 b y S i m o n s o n & As s o c i a t e s A r c h i t e c t s , L . L . C . NO T F O R C O N S T R U C T I O N SAA J: \ 2 0 2 2 \ 2 2 0 1 1 U A v e n u e - S i n g l e F a m i l y R e n t a l s , W a u ke e , I A \ C A D - A r c h \ 2 2 0 1 1 _ P e t e r s o n C l u b h o u s e . r v t 6/ 8 / 2 0 2 2 7 : 1 8 : 3 1 P M PE T E R S O N T O W N H O U S E S U A V E N U E WA U K E E , I O W A 22011 A-201 EXTERIOR ELEVATIONS 1. REFER TO ADDITIONAL NOTES AND REQUIREMENTS ON ALL OTHER DOCUMENTS AND OTHER DISCIPLINES DOCUMENTS. 2. ALL CONDUIT RUNS & SERVICE LINES SHALL BE GROUPED TOGETHER IN A NEAT & ORDERLY MANNER AND SHOULD PENETRATE THE WALL AT THE LOWEST POINT AND ARE NOT TO RUN OVER THE TOP OF PARAPET. ALL OTHER CONDUITS & JUNCTION BOXES FOR EXTERIOR FIXTURES & EQUIPMENT SHALL BE FULLY CONCEALED WITHIN THE BUILDING CONSTRUCTION. 3. ALL HORIZONTAL TRANSITIONS BETWEEN DIFFERENT MATERIALS SHALL BE FLASHED CONTINUOUS FROM UP BEHIND UPPER MATERIAL AND EXTEND OVER TO EXTERIOR FACE OF LOWER MATERIAL WITH DRIP EDGE. 4. ANY RETURNS OR BLIND ELEVATIONS NOT SHOWN SHALL BE SIMILAR IN MATERIAL AND MAKEUP TO ADJACENT CONDITIONS OR OTHER SIMILAR CONDITIONS. 5. NO EXPOSED MASONRY/MATERIAL CORES. MASONRY RETURNS AT WINDOWS/OPENINGS ARE REQUIRED IF FRAMING IS NOT DEEP ENOUGH TO PROVIDE CLOSURE AT THE BACKSIDE OF MASONRY FOR AN EFFECTIVELY SEALED JOINT. 6. INSTALL VERTICAL EXPANSION JOINTS PER STRUCTURAL OR MINIMAL AT COLUMN/GRID LINES AND AT THE HEAD OF DOOR JAMBS/OPENINGS OR AS OTHERWISE NOTED OR WHERE REQUIRED PER STANDARD MATERIAL PRACTICE TO REDUCE STRESS CRACKING. NO CONTROL JOINT/EXPANSION JOINT AT MAIN STRUCTURAL BEARING LOCATIONS. VERIFY JOINTS WITH ARCHITECT. 7. CAULK & SEAL ALL TRANSITION-CONTROL-EXPANSION AT ALL EXTERIOR MATERIALS. 8. PROVIDE CAST REGLETS JUST IN FROM THE OUTER EDGE ON UNDERSIDE OF FACE MATERIAL OR DRIP EDGE AT ALL OVERHANGS & SOFFITS. 9. INSULATE AND SEAL TO ENSURE ADEQUATE AIR INFILTRATION BARRIER AROUND ALL EXTERIOR PENETRATIONS TO PREVENT WATER AND SPRINKLER PIPE FREEZING. 10. WHERE EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF PAVING TO BE 1/4" LOWER THAN INTERIOR FINISH FLOOR, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. WHERE DOOR STOOP, 48" OUT FROM DOOR 1:48(2%) MAX. SLOPE, AFTER 48" AWAY FROM DOOR 1:20(5%) MAXIMUM SLOPE TO PUBLIC WAY. (REFER TO CIVIL) 11. WHERE NO EXTERIOR PAVING ADJACENT TO BUILDING, TOP OF FINISHED LANDSCAPE A MINIMUM OF 4" BELOW INTERIOR FINISH FLOOR AND 4” BELOW EXTERIOR WALL FLASHING/WEEPS, SLOPING CONTINUOUSLY AWAY FROM BUILDING A MINIMUM OF 5’. (REFER TO CIVIL) 12. ADDRESS SHALL BE PROVIDED ON STREET SIDE OF BUILDING AND ON MONUMENT SIGN. NUMBERS A MINIMUM 5 INCH CONTRASTING COLOR NUMBERS WITH MINIMUM 1/2" STROKE. 13. IF ANY SIGNAGE OR SIGN BASE IS SHOWN IT IS FOR REFERENCE ONLY, FINAL DESIGNS AND/OR ALLOWANCES SHALL BE DETERMINED WITH APPROVED SIGNAGE PERMIT(S). ACTUAL DETAILS & DIMENSIONS MAY VARY AND ARE SUBJECT TO CHANGE. ALL DRAWINGS ARE SUBJECT TO AUTHORITY HAVING JURISDICTION APPROVAL. SIGNAGE SHOWN DOES NOT REPRESENT ALLOWABLE SIGNAGE PERMITTING/APPROVAL OF ALL SIGNAGE PER CURRENT CITY ORDINANCE BY OTHERS. GENERAL EXTERIOR ELEVATION NOTES: SCALE:3/16" = 1'-0"1 EAST ELEVATION SCALE:3/16" = 1'-0"2 WEST ELEVATION SCALE:3/16" = 1'-0"3 NORTH ELEVATION SCALE:3/16" = 1'-0"4 SOUTH ELEVATION Rev. # Issue / Revision Date CL U B H O U S E 3D VIEW EXTERIOR MATERIAL FINISHES ELEVATIONS SHOW SCHEMATIC COLORS AND TEXTURES OF INTENDED EXTERIOR MATERIAL FINISHES. MATERIALS TO CREATE THESE ELEVATIONS MAY INCLUDE A MIXTURE OF ANY OF THE FOLLOWING MATERIALS: • VINYL SIDING • FIBER CEMENT PANEL • FIBER CEMENT LAP • FIBER CEMENT BOARD & BATTEN • THIN BRICK OR STONE • METAL PANEL 3D VIEW