HomeMy WebLinkAbout2022-09-06 J06 WILCx Addition_Site PlanAGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: September 6, 2022 AGENDA ITEM:Consideration of approval of a resolution approving a site plan for WILCx Addition FORMAT:Resolution SYNOPSIS INCLUDING PRO & CON: Waukee Community School District requests approval of a site plan to authorize the construction of a building addition to the current WILC building located at the northwest corner of SE L.A. Grant Parkway and Ashworth Road The building addition will be approximately 18,636 square-feet and will be approximately the same height as the current WILC Building. The addition includes several overhead doors and an outdoor courtyard space between the buildings. Access to the site will not change with these improvements. Existing access is provided from both SE Ashworth Road and SE LA Grant Parkway. The site plan proposes the removal of 17 parking stalls, but will still exceed the required 120 spaces by providing 336 spaces on the site. The applicant has provided elevations for the proposed building on the site. The design and materials are consistent with the Site Plan Ordinance. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning Commission reviewed this project at the August 23, 2022, Commission Meeting and recommended approval subject to remaining staff comments: Consider a request from Waukee Community School District for approval of a Site Plan for WILCx Building Addition [295 SE Ashworth Road] Community Development Director, Andy Kass, provided an outline of the project, as shown in the staff report. The scope of the project includes a building addition to the WILC building at 295 SE Ashworth Road, owned by Waukee Community School District. The project includes an 18,636-square foot building addition that will include several overhead doors and an outdoor courtyard. Several parking spaces will be removed and relocated. Access to the site will not change and no new sidewalks or trails are proposed. All public utilities exist and will be extended to service the addition. J6 The building is proposed to be constructed of cast-in-place concrete walls, aluminum panels, glass, fiber cement panels and polycarbonate panels. Staff recommends approval of the Site Plan subject to remaining staff comments. Commissioner Broderick asked if the only connection between the two buildings was on the first floor. Mr. Kass believed that was the case. Commissioner Hoifeldt asked about fire separation and fire rated walls for the automotive repair section of the addition. The architect for the project confirmed that it would be a non-separated occupancy based on the limited scope. Commissioner Hoifeldt then asked if there would be any painting areas. The applicant stated they were planning on open air spaces for flexibility and possibly some 8x8 self-contained paint stalls. Prior to any motions, Commissioner Streit recuses himself from the vote due to a conflict of interest. Motion was made by Alex Broderick to approve the Site Plan as presented. The motion was seconded by Cherian Koshy. On voice vote: All ayes: Motion carries 4-0. STAFF REVIEW AND COMMENT: Staff recommends approval of the site plan subject to remaining staff comments. RECOMMENDATION: Approve the resolution subject to remaining staff comments. ATTACHMENTS: I. Proposed Resolution II. Staff Report III. Site Plan & Elevations PREPARED BY:Melissa DeBoer, AICP, Senior Planner REVIEWED BY: THE CITY OF WAUKEE, IOWA RESOLUTION 2022- APPROVING THE SITE PLAN FOR WILCX BUILDING ADDITION IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Site Plan for WILCx Addition, subject to remaining staff comments on August 23, 2022; AND, WHEREAS, the Site Plan for WILCx Addition is in general conformance with §160 – Site and Building Development Standards Ordinance of the Waukee Municipal Code; AND, WHEREAS, the Site Plan for WILCx Addition is in general conformance with §161 – Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND, NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 6th day of September, 2022 that the Site Plan for WILCx Addition is approved. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Anna Bergman Pierce R. Charles Bottenberg Chris Crone Larry R. Lyon Ben Sinclair PLANNING AND ZONING COMMISSION STAFF REPORT PROJECT: WILCx Building Addition – Site Plan PREPARED BY: Melissa DeBoer, AICP – Senior Planner REPORT DATE: August 19, 2022 MEETING DATE: August 23, 2022 GENERAL INFORMATION Owner/Applicant: Waukee Community School District Owner’s Representative: James Rodemyer, P.E. with Bishop Engineering Request: The applicant is requesting approval of a site plan for a building addition. Location and Size: Property is generally located north of SE Ashworth Road and west of SE LA Grant Parkway, containing approximately 12.19 acres. Property Address: 295 SE Ashworth Road AREA MAP ABOVE: Aerial of subject property (outlined in BLUE) in relation to the surrounding area. August 19, 2022 2 of 3 LAND USES AND ZONING Location Existing Land Use Comprehensive Plan Current Zoning Property in Question Waukee Community School District – WILC Building Institutional A-1 (Agricultural District) North Vision Soccer Academy / Waukee Timberline Middle School Institutional A-1 (Agricultural District) South Rural Residential in Dallas County Rural Residential N/A – Dallas County East Future Launch Townhomes Medium Density Residential K-MF-MED (Kettlestone Multi-Family Stacked Medium District) West Timberline Campground in Dallas County Park N/A – Dallas County PROJECT DESCRIPTION The project includes an 18,636 square foot addition onto the existing building. The building addition will include several overhead doors and an outdoor courtyard space between the addition and the existing building. Several parking stalls along the north side of the site will be removed to make room for the addition, a few new parking spaces will be provided to the east of the new addition. The project also includes the removal and replacement of existing pavement within the areas immediately adjacent to the building. ACCESS AND PARKING Existing accesses into this site are provided from both SE Ashworth Road and SE LA Grant Parkway. No changes are proposed to these accesses. The proposed site plan will remove a total of 17 parking spaces. The site will provide a total of 336 parking stalls, exceeding the required 120 parking stalls per the code. SIDEWALKS/TRAILS No new public sidewalks or trails are proposed with this project. UTILITIES The new addition will be serviced with all public utilities. Water and sanitary sewer will be provided off of the mains along SE LA Grant Parkway. Stormwater detention is provided at the southwest corner of the overall school property. LANDSCAPING & OPEN SPACE A minimum of 20% of the site is required to be open space. The total amount of open space proposed is 57%. The applicant has provided the required amount of plantings per the landscaping ordinance. August 19, 2022 3 of 3 ELEVATIONS The elevations of the building are proposed to be constructed of cast-in-place concrete wall, aluminum panel, glass, fiber cement panel, and polycarbonate panel. STAFF RECOMMENDATION The site plan is in general conformance with the Site Plan Ordinance and Comprehensive Plan. Staff recommends approval of the site plan subject to remaining staff comments. WILCx BUILDING ADDITION SITE PLAN IOWAONE CALL 1-800-292-8989 www.iowaonecall.com 811 Know what's below. Call before you dig. PROPERTY DESCRIPTION: LOT 1 TIMBERLINE MIDDLE SCHOOL PLAT 1, WAUKEE, DALLAS COUNTY, IOWA. ADDRESS: 295 SE ASHWORTH ROAD WAUKEE, IOWA 50263 OWNER/PREPARED FOR: WAUKEE COMMUNITY SCHOOL DISTRICT ATTN: KIRK JOHNSON 560 SE UNIVERSITY AVE WAUKEE, IA 50263 PH: (515) 987-5161 ZONING: A1 - AGRICULTURAL FRONT YARD SETBACK - 35 FEET REAR YARD SETBACK - 35 FEET SIDE YARD SETBACK - 35 FEET MAXIMUM BUILDING HEIGHT - 3 STORIES OR 40 FEET PARKING REQUIREMENTS: PARKING REQUIREMENTS: 1 SPACE PER EMPLOYEE + 1 SPACE PER 5 STUDENTS PARKING REQUIRED = 20 + 500/5 = 120 PARKING STALLS REQUIRED PARKING PROVIDED = 336 STALLS (INCL 8 HC STALLS) OPEN SPACE & IMPERVIOUS SURFACE: TOTAL AREA - 531,200 SF REQUIRED OPEN SPACE - 106,240 SF (20%) EXISITNG IMPERVIOUS SURFACE = 214,000 SF IMPERVIOUS SURFACE ADDED = 14,000 SF IMPERVIOUS SURFACE = 228,000 SF (43%) PROVIDED OPEN SPACE - 303,200 SF (57%) BENCHMARK: BENCHMARK DATUM = CITY DATUM OR NAVD88, GEOID 12A) POINT #9015 NORTHING = 2627.919 EASTING = 3986.324 ELEVATION = 1005.216 DESCRIPTION: FOUND CUT X POINT #9022 NORTHING = 2456.165 EASTING = 4404.40 ELEVATION = 1015.656 DESCRIPTION: FOUND CUT X VICINITY MAP NOT TO SCALE COPYRIGHT 2022 BISHOP ENGINEERING. THIS DOCUMENT AND THE INFORMATION CONTAINED MAY NOT BE REPRODUCED OR EXCERPTED WITHOUT THE EXPRESS WRITTEN PERMISSION OF BISHOP ENGINEERING. UNAUTHORIZED COPYING OR DISCLOSURE OF CONSTRUCTION USE ARE PROHIBITED BY COPYRIGHT LAW. LEGEND: SAN SANITARY SEWER ST STORM SEWER W WATER LINE G GAS LINE U/E UNDERGROUND ELECTRIC O/E OVERHEAD ELECTRIC TELE TELEPHONE LINE F/O FIBER OPTIC CATV CABLE TV STORM MANHOLE CURB INTAKE SURFACE INTAKE FLARED END SECTION SANITARY MANHOLE CLEANOUT FIRE HYDRANT SPRINKLER IRRIGATION CONTROL VALVE WATER MANHOLE WELL WATER VALVE WATER SHUT OFF YARD HYDRANT ELECTRIC MANHOLE ELECTRIC METER ELECTRIC RISER ELECTRIC VAULT POWER POLE TRANSFORMER POLE LIGHT POLE ELECTRIC JUNCTION BOX ELECTRIC PANEL TRANSFORMER GROUND LIGHT GUY WIRE ELECTRIC HANDHOLE GAS METER GAS VALVE AIR CONDITIONING UNIT TELEPHONE RISER TELEPHONE VAULT TELEPHONE MANHOLE TRAFFIC SIGNAL MANHOLE FIBER OPTIC MANHOLE FIBER OPTIC RISER FIBER OPTIC VAULT CABLE TV RISER SIGN BOLLARD 7 DENOTES NUMBER OF PARKING STALLS PROPERTY CORNER - FOUND AS NOTED PROPERTY CORNER- PLACED AS NOTED SECTION CORNER - FOUND AS NOTED D S CO H Y D I CV W WSO YA DR E EM E ELEC EJ EP GM GV A/C T TEL T TS FO F/O TV W WV SHEET INDEX: C0.1 COVER SHEET C1.1 SITE DEMOLITION PLAN C2.1 SITE LAYOUT PLAN C3.1 GRADING PLAN C4.1 UTILITY PLAN C5.1 LANDSCAPE PLAN C6.1 SITE DETAILS SHEET C7.1 EROSION CONTROL PLAN PLANNING ARCHITECTUREINTERIORS OWNER SIGN-OFF: REVISIONS: DATE NAME CONSULTANT: 303 Watson Powell Jr. Way Suite 200 Des Moines, Iowa 50309 515.633.2941 515.633.2942 Fax www.invisionarch.com Copyright C 2022 SHEET NAME: PROJECT NO: DATE: SHEET SET: SHEET: PRELIMINARY NOT FOR CONSTRUCTION BISHOP ENGINEERING COMPANY, INC IMEG CORP IMEG CORP CIVIL STRUCTURAL MEP 08.23.2022 21209 WI L C x 29 5 S E A S H W O R T H R O A D W A U K E E , I A 5 0 2 6 3 WA U K E E C O M M U N I T Y S C H O O L D I S T R I C T 3RD CITY SUBMITTAL Description Date No. L: \ L A N D P R O J E C T S 2 0 2 2 \ 2 2 0 0 6 1 W A U K E E W I L C E X P A N S I O N \ D W G \ C 0 C O V E R . D W G 8/ 2 3 / 2 0 2 2 1 1 : 2 6 : 4 7 AM Bi s h o p E n g i n e e r i n g UTILITY NOTE: THE LOCATION OF THE UTILITIES INDICATED ON THE PLANS HAVE BEEN TAKEN FROM THE FIELD SURVEY, EXISTING PUBLIC RECORDS, AND PLANS PROVIDED BY OTHERS. SURFACE UTILITY LOCATIONS HAVE BEEN FIELD LOCATED BY BISHOP ENGINEERING, UNLESS OTHERWISE NOTED. ALL UNDERGROUND UTILITY LOCATIONS ARE APPROXIMATE LOCATIONS ONLY. BISHOP ENGINEERING DOES NOT GUARANTEE THE UNDERGROUND LOCATION OF ANY UTILITIES SHOWN. IT SHALL BE THE DUTY OF THE CONTRACTOR TO DETERMINE THE LOCATION AND DEPTH OF ANY UNDERGROUND UTILITIES SHOWN AND IF ANY ADDITIONAL UTILITIES, OTHER THAN THOSE SHOWN ON THE PLANS, MAY BE PRESENT. A REQUEST WAS MADE TO IOWA ONE CALL FOR UTILITY PROVIDERS TO VERIFY, LOCATE, AND MARK THEIR UTILITIES IN THE FIELD. ABBREVIATIONS: AC ACRES ASPH ASPHALT BK BOOK CONC CONCRETE D DEEDED DISTANCE EX EXISTING ENCL ENCLOSURE FF FINISHED FLOOR FL FLOW LINE FRAC FRACTIONAL M MEASURED DISTANCE MH MANHOLE OPC ORANGE PLASTIC CAP P PLATTED DISTANCE PG PAGE POB POINT OF BEGINNING POC POINT OF COMMENCEMENT PRA PREVIOUSLY RECORDED AS PUE PUBLIC UTILITY EASEMENT ROW RIGHT OF WAY RPC RED PLASTIC CAP SF SQUARE FEET SAN SANITARY TYP TYPICAL YPC YELLOW PLASTIC CAP N NORTH S SOUTH E EAST W WEST F/O C0.1 - C7.1 COVER SHEET C0.1 SITE STAKING NOTES: 1.CONTRACTOR IS REQUIRED TO HAVE ALL STAKING DONE UNDER THE SUPERVISION OF A LICENSED LAND SURVEYOR AND IN COORDINATION WITH THE PROJECT ENGINEER. 2.CONTRACTOR IS REQUIRED TO HAVE ALL STAKING DONE DIRECTLY UNDER THE GENERAL CONTRACTOR BY A SINGLE COMPANY. 3.STAKING DOES NOT RELIEVE CONTRACTOR OF ULTIMATE RESPONSIBILITY TO CONSTRUCT THE PROJECT PER PLAN. SOILS REPORT: 1.REFERENCE ALLENDER BUTZKE SOILS REPORT (PN XXXXX) FOR ADDITIONAL SOILS INFORMATION INCLUDING BUT NOT LIMITED TO SUBGRADE INFORMATION, FOOTING DESIGN, AND ANY POSSIBLE OVER EXCAVATION DUE TO POOR SOILS. PAVEMENT SECTIONS ON THE PLANS GOVERN OVER PAVEMENT THICKNESS IN THE SOILS REPORT. EARTHWORK BALANCE NOTES: 1.SOIL IMPORT OR EXPORT ON THIS PROJECT SHALL BE CONSIDERED INCIDENTAL AND WILL NOT BE MEASURED OR PAID FOR SEPARATELY. CONTRACTOR RESPONSIBLE FOR MAKING THE SITE EARTHWORK BALANCE. 2.THIS INCLUDES BUT IS NOT LIMITED TO TOPSOIL, POOR SOILS AND STRUCTURAL FILL NECESSARY TO MEET PROJECT PLANS AND SPECIFICATIONS. PAVEMENT PLACEMENT NOTES: 1.SEE PROJECT SPECIFICATION SECTION 32 13 13 FOR LASER SCREED REQUIREMENTS. STORM & SANITARY TELEVISING NOTES: 1.CONTRACTOR IS REQUIRED TO TELEVISE ALL SANITARY AND STORM SEWER SYSTEM PRIOR TO PAVING OPERATIONS. 2.CONTRACTOR SHALL SEND VIDEO INSPECTION TO THE ENGINEER FOR APPROVAL PRIOR TO PAVING. 3.CONTRACTOR SHALL PROVIDE COPIES OF THE REPORTS AND VIDEOS TO THE WAUKEE ENGINEERING DEPARTMENT FOR APPROVAL PRIOR TO PAVING. UTILITY CONFLICT NOTES: 1.UTILITY CONFLICTS MAY EXIST ACROSS THE SITE WITH NEW UTILITIES, GRADING, PAVING ETC. MOST UTILITY CONFLICTS HAVE BEEN CALLED OUT FOR CONTRACTOR CONVENIENCE. 2.CONTRACTOR IS RESPONSIBLE FOR ALL UTILITY CONFLICTS THAT ARE EITHER CALLED OUT ON THE PLANS OR THAT CAN BE SEEN ON THE PLANS BETWEEN AN EXISTING UTILITY AND PROPOSED CONSTRUCTION. 3.CONTRACTOR SHALL USE O-RING GASKET JOINTS FOR STORM SEWER AND SANITARY SEWER AT CROSSINGS WITH WATER WHERE STORM OR SANITARY SEWER CROSSES OVER OR LESS THAN 18 INCHES BELOW WATER. O-RING GASKET JOINTS SHALL BE EXTENDED UNTIL WATER AND SEWER ARE AT LEAST 10 FEET APART. ALL O-RING GASKET JOINTS SHALL BE CONSIDERED INCIDENTAL TO BID. IF N-12 PIPE IS USED FOR STORM SEWER, CONTRACTOR SHALL USE WATER-TIGHT N-12 PIPE, CENTERED ON THE CROSSING. 4.FOR ALL CRITICAL CROSSINGS WITH EXISTING UTILITIES, THE ELEVATION OF THE EXISTING UTILITY SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. NOTIFY BISHOP ENGINEERING PRIOR TO CONSTRUCTION IF A CONFLICT EXISTS. GENERAL NOTES: 1.ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2020 WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND THE 2022 SUDAS STANDARD SPECIFICATIONS. THE CITY OF WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT MUST BE NOTIFIED BY ALL CONTRACTORS 48 HOURS PRIOR TO COMMENCING WORK AND PRIOR TO ANY WEEKEND OR HOLIDAY WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING WAUKEE DEVELOPMENT SERVICES DEPARTMENT 1 WEEK PRIOR TO ANY PLANNED WORK TO SCHEDULE A PRE-CONSTRUCTION MEETING. 2.IN EVENT OF A DISCREPANCY BETWEEN THE QUANTITY ESTIMATES AND THE DETAILED PLANS, THE DETAILED PLANS SHALL GOVERN. 3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION OF ALL UTILITIES. ANY DAMAGE TO SAID UTILITIES SHALL BE REPAIRED AT THE CONTRACTORS EXPENSE. 4.ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE CURRENT O.S.H.A. CODES AND STANDARDS. NOTHING INDICATED ON THESE PLANS SHALL RELIEVE THE CONTRACTOR FROM COMPLYING WITH THE APPROPRIATE SAFETY REGULATIONS. 5.ALL NECESSARY CONSTRUCTION SIGNS, BARRICADES AND OTHER TRAFFIC CONTROL DEVICES REQUIRED DURING CONSTRUCTION WILL BE FURNISHED BY THE CONTRACTOR. SIGNS, BARRICADES AND OTHER TRAFFIC CONTROL DEVICES MUST BE IN CONFORMANCE WITH THE "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS" AND CITY OF WAUKEE REQUIREMENTS. 6.BISHOP ENGINEERING SHALL NOT BE LIABLE FOR ANY INJURIES THAT HAPPEN ON SITE. THIS SHALL INCLUDE BUT NOT BE LIMITED TO TRENCH COLLAPSES FROM VARYING SOIL CONDITIONS OR INJURIES CAUSED BY UNDERGROUND UTILITIES INCLUDING UTILITIES THAT ARE NOT SHOWN ON PLAN. 7.THE CONTRACTOR IS LIABLE FOR ALL DAMAGES TO PUBLIC OR PRIVATE PROPERTY CAUSED BY THEIR ACTION OR INACTION IN PROVIDING FOR STORM WATER FLOW DURING CONSTRUCTION. DO NOT RESTRICT FLOWS IN EXISTING DRAINAGE CHANNELS, STORM SEWER, OR FACILITIES. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REPAIRS. 8.THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER A SCHEDULE FOR PERFORMANCE OF WORK ITEMS. THIS SCHEDULE SHALL BE PROVIDED BY THE CONTRACTOR AT THE PROJECT PRECONSTRUCTION CONFERENCE. NO WORK SHALL BEGIN UNTIL A SCHEDULE HAS BEEN SUBMITTED AND ACCEPTED. THE CONTRACTOR SHALL THEN PERFORM WORK TO CONFORM TO THE ACCEPTED SCHEDULE. 9.LABORATORY TESTS SHALL BE PERFORMED BY THE OWNER UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL PROVIDE SAMPLES OF MATERIAL REQUIRED FOR LABORATORY TESTS AND TESTING IN ACCORDANCE WITH THE URBAN STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS. 10.THE CONTRACTOR SHALL PROTECT ALL STRUCTURES NOT SHOWN AS REMOVALS ON THE PLANS. 11.THE CONTRACTOR SHALL OBTAIN ANY AND ALL NECESSARY PERMITS PRIOR TO ANY CONSTRUCTION. CONTRACTOR SHALL WORK WITH OWNER OR OWNERS REPRESENTATIVE ON ALL REQUIRED STORM WATER DISCHARGE PERMITS FROM THE IOWA DEPARTMENT OF NATURAL RESOURCES AND THE CITY OF WAUKEE. 12.GRADING AND EROSION CONTROL SHALL BE DONE IN ACCORDANCE WITH THE APPROVED GRADING PLAN, SWPPP, NPDES DOCUMENTS, AND IOWA DEPARTMENT OF NATURAL RESOURCES REQUIREMENTS. 13.THE CONTRACTOR SHALL PICK UP ANY DEBRIS SPILLED ONTO THE ADJACENT RIGHT OF WAY OR ABUTTING PROPERTIES AS THE RESULT OF CONSTRUCTION, AT THE END OF EACH WORK DAY AND PRIOR TO A RAIN EVENT. 14.THE CONTRACTOR IS RESPONSIBLE FOR THE PROMPT REMOVAL OF ALL MUD THAT HAS BEEN TRACKED OR WASHED UNTO ADJACENT PROPERTY OR RIGHT OF WAY UNTIL SUCH TIME THAT PERMANENT VEGETATION HAS BEEN ESTABLISHED. 15.DISPOSE OF ALL EXCESS MATERIALS AND TRASH IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL REQUIREMENTS. PROVIDE WASTE AREAS OR DISPOSAL SITES FOR EXCESS MATERIALS NOT DESIRABLE FOR INCORPORATION INTO THE PROJECT. 16.ANY PROPOSED CHANGES TO THE APPROVED PLAN SET DURING CONSTRUCTION MUST RECEIVE WRITTEN APPROVAL FROM THE CITY OF WAUKEE DEVELOPMENT SERVICES DEPARTMENT AND DESIGN ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY CHANGES MADE DURING CONSTRUCTION THAT HAVE NOT RECEIVED WRITTEN APPROVAL FROM THE CITY OF WAUKEE DEVELOPMENT SERVICES DEPARTMENT. 17.CONTRACTOR SHALL PROVIDE THE CITY OF WAUKEE ENGINEERING DEPARTMENT WITH A LIST OF QUANTITIES FOR SCHEDULING INSPECTION PURPOSES. 18.CONTRACTOR SHALL PROTECT ALL EXISTING PAVING, TREES, LANDSCAPING, SITE FEATURES, ETC THAT ARE NOT CALLED OUT FOR REMOVAL ON THE PLANS. PAVING NOTES: 1.THE PAVING/ GRADING CONTRACTOR SHALL BACKFILL THE PAVING SLAB AND FINE GRADE THE RIGHT OF WAY AS SOON AFTER THE PAVING AS POSSIBLE. ALL AREAS SHALL BE SEEDED IN ACCORDANCE WITH CITY OF WAUKEE STANDARD SPECIFICATIONS AND THE CURRENT VERSION OF SUDAS. 2.SUBGRADE PREPARATION AND PAVEMENTS WILL BE CONSTRUCTED FOLLOWING RECOMMENDATIONS IN THE SOILS REPORT. APPROVED SOILS ENGINEER MUST SIGN OFF ON SUBASE PRIOR TO ANY PAVEMENT BEING PLACED. 3.SEE DETAILS FOR ALL PAVEMENT THICKNESS. 4.DETECTABLE WARNING PANELS CALLED OUT ON PLANS SHALL BE PER A.D.A. REGULATIONS. PANEL TYPE & COLOR SHALL BE PER CITY STANDARD. 5.ALL WALKS, PARKING LOTS, HANDICAP PARKING, RAMPS, ETC. SHALL COMPLY WITH ALL A.D.A. AND CITY CODES. HANDICAP PARKING SIGNAGE IS REQUIRED FOR ALL HANDICAP STALLS AND SHALL BE CONSIDERED INCIDENTAL. IN EVENT OF A DISCREPANCY BETWEEN THE PLANS AND THE A.D.A./CITY CODES THE A.D.A./CITY CODES SHALL GOVERN. CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING A.D.A. CODES ARE MET. 6.ALL PAVEMENT REPLACEMENT SHALL COMPLY WITH THE WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS. UTILITY NOTES: 1.QUANTITY CALLOUTS ON PIPE LENGTHS ARE APPROXIMATE AND SHOULD BE USED FOR REFERENCE ONLY. 2.THE CONTRACTOR SHALL COORDINATE THE ADJUSTMENT OF ANY AND ALL EXISTING AND PROPOSED UTILITIES TO PROPOSED GRADES. EXISTING UTILITIES SHALL BE RAISED OR LOWERED IN ACCORDANCE WITH THE UTILITY OWNER REQUIREMENTS. ANY NECESSARY ADJUSTMENTS SHALL BE CONSIDERED INCIDENTAL TO CONSTRUCTION. 3.ALL PROPOSED RCP STORM SEWER PIPE JOINTS SHALL BE FABRIC WRAPPED AND THE LAST 3 PIPE SECTIONS ON THE APRON SHALL BE TIED WITH RF-14 TYPE II CONNECTORS. ALL APRONS SHALL HAVE A STANDARD FOOTING AND TRASH GUARD. ALL FLARED END SECTIONS SHALL HAVE A 3' WIDE CLAY WATERSTOP (SUDAS SW-105). 4.ALL RIP RAP CALLED OUT ON PLANS SHALL BE UNDERLAIN WITH ENGINEERING FABRIC. 5.ALL STRUCTURE SIZES CALLED OUT ON PLANS ARE MINIMUM INSIDE WALL DIMENSIONS. 6.ALL STRUCTURES CALLED OUT AS "MODIFIED" OR "SPECIAL" SHALL BE ENGINEERED BY THE PRECASTER TO ENSURE STRUCTURE STABILITY. MODIFICATIONS INCLUDE ADDITIONAL WALL LENGTH TO ACCOUNT FOR LARGE PIPE DIAMETERS AND ADDITIONAL WALL WIDTH & BASE DEPTH TO ACCOUNT FOR DEEPER STRUCTURES. ANY AND ALL MODIFICATIONS TO STANDARD STRUCTURES SHALL BE CONSIDERED INCIDENTAL TO BID. 7.SANITARY SERVICES SHALL MAINTAIN 18" OF VERTICAL SEPARATION FROM THE WATERMAIN WITH 18" OF COMPACTED LOW PERMEABILITY SOIL BETWEEN THE UTILITIES WITHIN 10' OF THE CROSSING. 8.MANDREL AND PRESSURE TESTS SHALL BE REQUIRED FOR ALL PROPOSED SANITARY LINES, ALL SANITARY MANHOLES SHALL BE VACUUM TESTED. ALL SANITARY AND STORM LINES SHALL BE CLEANED AND TELEVISED PRIOR TO PAVING BY THE CONTRACTOR. THE CITY SHALL WITNESS ALL CLEANING AND TELEVISING, COPIES OF THE REPORTS AND VIDEOS SHALL BE PROVIDED TO THE CITY OF WAUKEE ENGINEERING DEPARTMENT. 9.ALL UTILITIES SHALL BE TESTED TO CITY OF WAUKEE STANDARDS AND THE CITY OF WAUKEE ENGINEERING DEPARTMENT SHALL WITNESS ALL TESTING. 10.ALL WATER LINE MATERIAL SHALL BE C-900 UNLESS NOTED OTHERWISE ON PLANS. SIZE OF WATERMAIN AS SHOWN ON PLANS. 11.THRUST BLOCKS SHALL BE INSTALLED AS REQUIRED AND SHALL BE CONSIDERED INCIDENTAL TO WATERMAIN CONSTRUCTION. 12.PROPOSED WATERMAIN SHALL BE PRESSURE TESTED, BACTERIA TESTED AND CHLORINATED. THE FILLING OF THE WATER MAIN SHALL BE DONE BY THE CITY OF WAUKEE. 13.TRACER WIRE SHALL BE ADDED TO ALL WATER MAIN, AND BROUGHT TO THE SURFACE AT EVERY HYDRANT. 14.ALL HYDRANTS WILL IMMEDIATELY BE COVERED WITH A BLACK PLASTIC BAG (OR EQUIVALENT) ONCE THE HYDRANT IS INSTALLED. THE CITY OF WAUKEE WILL NOTIFY THE CONTRACTOR WHEN THE BAGS CAN BE REMOVED. 15.THE MINIMUM HYDRANT LEAD SHALL BE 3.5 FEET. 16.FIRE HYDRANT ASSEMBLY SHALL INCLUDE TEE, BRANCH, VALVE & HYDRANT AND A 5" STORZ CONNECTION. 17.ANY AND ALL HYDRANT AND VALVE EXTENSIONS, TOGETHER WITH VERTICAL BENDS, SHALL BE CONSIDERED INCIDENTAL TO WATER MAIN CONSTRUCTION. NO ADDITIONAL PAYMENT WILL BE PROVIDED FOR INCIDENTAL ITEMS. 18.ALL UTILITY CONNECTIONS TO EXISTING UTILITIES SHALL BE COORDINATED WITH THE CITY OF WAUKEE ENGINEERING DEPARTMENT. EROSION CONTROL NOTES: 1.DISTURBED AREA = 0.90 ACRES MORE OR LESS, THUS AN NPDES PERMIT IS NOT REQUIRED. 2.CONTRACTOR SHALL STILL BE REQUIRED TO INSTALL EROSION CONTROL BMP'S TO LIMIT SEDIMENT FROM LEAVING THE SITE. 3.THIS PROJECT INCLUDES SAWCUTTING OR CONCRETE GRINDING SO PROTECTION OF STORM SEWERS AND DRAINAGE WAYS WILL NEED TO BE PROVIDED FROM SLURRY FROM THE CONCRETE OPERATIONS. SEE SWPPP SHEET AND NARRATIVE FOR ADDITIONAL DETAILS. MONUMENT AND BUILDING SIGNAGE: 1.ALL MONUMENT SIGNS ARE SUBJECT TO REVIEW BY THE CITY OF WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT 2.CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL SIGN PERMITS PRIOR TO INSTALLATION OF ANY GROUND OR BUILDING SIGNAGE AND SHALL ENSURE COMPLIANCE WITH ALL CITY REGULATIONS. SECURITY NOTES: 1.CONTRACTOR RESPONSIBLE FOR SECURITY OF THE SITE. 2.TEMPORARY FENCES OR ANY OTHER SECURITY MEASURES ARE THE RESPONSIBILITY OF THE CONTRACTOR. 3.NO SECURITY MEASURES WILL BE ELIGIBLE FOR A CHANGE ORDER AND MUST BE INCLUDED IN THE BASE BID. SPECIFICATIONS NOTES: 1.ALLWORK SHALL BE DONE IN ACCORDANCE WITH THE WILCx BUILDING ADDITION PROJECT SPECIFICATIONS, THE CITY OF WAUKEE SPECIFICATIONS AND SUDAS SPECIFICATIONS. 2.FOR ANY DISCROPANCIES BETWEEN THE WILCx BUILDING ADDITION PROJECT SPECIFICATIONS AND THE CURRENT EDITION OF IOWA SUDAS, THE PROJECT SPECIFICATION SHALL GOVERN UNLESS DIRECTED OTHERWISE BY THE CITY OF WAUKEE OR THE PROJECT ENGINEER. 3.FOR ALL SPECIFICATION DISCREPANCIES, PROJECT ENGINEER SHALL BE CONTACTED PRIOR TO PROCEEDING WITH CONSTRUCTION. IF ENGINEER IS NOT CONTACTED, CONTRACTOR SHALL BE RESPONSIBLE FOR ANY PROBLEMS THAT RESULT FROM SAID DISCREPANCIES. 4.FOR ALL SPECIFICATION DISCREPANCIES, CONTRACTOR MUST OBTAIN WRITTEN APPROVAL FROM THE CITY OF WAUKEE ENGINEERING DEPARTMENT FOR ANY CHANGES TO PROPOSED SITE INFRASTRUCTURE OR GRADES PRIOR TO PROCEEDING WITH ANY CHANGES. FIRE DEPARTMENT ACCESS NOTES: 1.AN APPROVED FIRE APPARATUS ACCESS ROAD SHALL BE PROVIDED FOR ALL BUILDINGS, OR PORTIONS OF A BUILDING AS SOON AS VERTICAL CONSTRUCTION OF THE BUILDING COMMENCES. 2.FIRE APPARATUS ACCESS ROAD SHALL COMPLY WITH THE REQUIREMENTS OF 2015 IFC 503.2 AND SHALL EXTEND TO WITHIN 150 FEET OF ALL EXTERIOR PORTIONS OF THE BUILDING AS MEASURED BY AN APPROVED ROUTE AROUND THE EXTERIOR OF THE BUILDING. 3.FIRE APPARATUS TRAIL (AS SHOWN ON PLANS) SHALL BE INSTALLED PRIOR TO BUILDING GOING VERTICAL. IF PAVEMENT IS NOT PLANNED TO BE INSTALLED PRIOR TO THE BUILDING GOING VERTICAL, THAN TEMPORARY ROCK ACCESS SHALL BE PROVIDED AROUND THE BUILDING AND CONNECTED TO THE ROCK CONSTRUCTION ENTRANCE. 4.ANY TEMPORARY ROCK USED FOR THE FIRE DEPARTMENT ACCESS ROUTE SHALL BE REMOVED FROM THE SITE PRIOR TO TOPSOIL SPREADING AND SEEDING. SEE TOPSOIL NOTES ON COVER SHEET AND GRADING PLAN. 5.ANY AND ALL FIRE APPARATUS ACCESS ROAD WORK NECESSARY TO COMPLY WITH WAUKEE FIRE DEPARTMENT REQUIREMENTS SHALL BE CONSIDERED INCIDENTAL TO BID. PAVEMENT SAWCUT NOTES: 1.CONTRACTOR(S) SHALL FOLLOW JOINTING AS SHOWN ON THE LAYOUT PLAN. IF CONTRACTOR(S) WANTS AN ALTERNATE JOINTING PLAN, CONTRACTOR(S) SHALL PROVIDE JOINTING PLAN TO JOEL JACKSON, BISHOP ENGINEERING (515-276-0467 OR JJACKSON@BISHOPENGR.COM) PRIOR TO ANY CONCRETE PAVEMENT INSTALLATION. 2.PAVEMENT MAY BE REQUIRED TO BE REMOVED AND REPLACED IF PLACED WITHOUT FOLLOWING PROVIDED JOINTING PLAN OR AN AN APPROVED ALTERNATE PLAN. 3.LONGITUDINAL JOINTS IN DRIVE LANES & THE OUTER MOST JOINT OF ALL PARKING AREAS SHALL BE SUDAS TYPE 'L-1' OR 'L-2' JOINTS AND HAVE STEEL. INTERIOR PARKING LOT JOINTS, OTHER THAN THE OUTER MOST JOINT, DO NOT NEED STEEL AND SHALL BE SUDAS TYPE 'B' JOINTS. 4.TYPICAL LONGITUDINAL JOINTS SHALL BE PLACED IN THE CENTER OF ALL DRIVE AISLES AND AT THE END OF ALL PARKING STALLS. 5.ALL TRANSVERSE JOINTS SHALL BE SUDAS TYPE 'C' OR TYPE 'DW' JOINTS WITH STEEL IN THE CASE OF A DAY'S WORK JOINT. LANDSCAPING NOTE: 1.CONTRACTOR SHALL BE RESPONSIBLE FOR SODDING THE DISTURBED AREA ON THE NORTH SIDE OF THE NORTHERN DRIVE, AS SHOWN ON THE LANDSCAPE PLAN. 2.ALL LANDSCAPING PLANTINGS IN THE AREAS DELINEATED ON THE LANDSCAPE PLAN WILL BE DONE BY THE OWNER OUTSIDE THE CONTRACT. SEE LANDSCAPE PLAN FOR ADDITIONAL INFORMATION. CP #89022 CP #9901 F F = 1 0 1 9 . 0 4 F F = 1 0 1 9 . 0 4 CO CO CO EP WV H Y D TBM: BURY BOLT ELEV=1020.40 EX INTAKE RIM=1018.03 INV W=1012.46 S EX SAN MH RIM=1017.62 TOP OF CO=1014.40 BOTTOM STRUCTURE=1008.40 WV H Y D TBM: BURY BOLT ELEV=1020.13 ELEC EX INTAKE RIM=1017.46 INV NE=1010.46 INV NW=1010.21 EX INTAKE RIM=1017.51 INV SW=1012.26 EX INTAKE RIM=1017.65 INV NE=1011.80 INV SW=1011.49 H Y D TBM: BURY BOLT ELEV=1017.69 WV EX INTAKE RIM=1017.84 FULL OF MUD S EX SAN MH RIM=1017.57 TOP OF CO= 1014.25 BOTTOM STRUCTURE=1008.25D EX STORM MH RIM=1017.46 INV E=1009.34 INV S=1008.96 4" TREE 4" TREE 4" TREE 4" TREE 4" TREE 4" TREE 4" TREE D EX STORM MH RIM=1016.50 INV N=1008.05 INV SE=1008.00 INV W=1007.90 EX INTAKE RIM=1017.78 INV E=1012.03 INV W=1011.73 S EX SAN MH RIM=1016.93 FL(N)=1010.93 ST 15" ST 15" ST 15" ST 15" ST 15" ST 15" ST 15" S T S T S T S T S T ST 15 " ST 15 " ST 15" ST 15"ST 15"ST 15" ST 15" ST 15" ST 15" ST 15" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W8"W8"W8"W8"W8"W8"W8"W8"W8"W8"W8"W8" W6" EXTISTING BUILDING FOOTPRINT = 35,770 SF FF = 1019.04 EX TRASH ENCLOSURE 1022 1021 10 1 8 101 9 1019 1018 1020 1019 1 0 1 7 1 0 1 6 1 0 1 5 1 0 1 8 101 7 1016 1017 1 0 1 7 101 6 1015 1014 10 1 3 1 0 1 8 1 0 1 6 1 0 1 5 1 0 1 4 101 8 1018 1018 1019 101 9 EX. COLUMN FOR SECOND FLOOR OVERHANG EX WALL EX CONCRETE EX CONCRETE EX CONCRETE EX CONCRETE EX CONCRETE EX BOLLARD (TYPICAL) EX CONCRETE WALK SAN 6" SA N 8 " F/O F/O F/O F/ O F/ O F/ O F/ O F/ O APPROXIMATE LOCATION PER WAUKEE COMMUNITY SCHOOLS MAP F/ O F/ O ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6" ST 6" SA N 6" SAN 6" SA N 10 " SA N 10 " 3" TREE 3" TREE3" TREE3" TREE 3" TREE 3" TREE 3" TREE 3" TREE EX CONCRETE EX C O N C R E T E EX C O L O R E D C O N C R E T E 36" TREE 18" TREE 18" PINE 24" PINE24" PINE12" PINE 6" TREE 18" TREE 8" TREE 12" PINE 6" TREE6" TREE 6" TREE 48" TREE 36" TREE 18" PINE 24" PINE 18" PINE12" PINE24" PINE6" TREE24" PINE24" PINE 24" PINE24" PINE24" PINE 8" TREE 8" TREE12" TREE 8" TREE 12" TREE 36" TREE S EX SAN MH RIM=1020.06 FL(N)=1010.01 FL(S)=1010.11 FUTURE TRAIL EA S E M E N T SA N S W R E A S E M E N T B K 2 0 1 4 P G 6 0 8 8 10 ' P . U . E . B K 2 0 1 3 P G 2 1 2 9 6 10' P.U.E. BK 2013 P G 2 1 2 9 6 10' P.U.E. BK 2013 P G 2 1 2 9 6 10 ' P . U . E . B K 2 0 1 3 P G 2 1 2 9 6 SA N S W R E A S E M E N T B K 2 0 1 4 P G 6 0 8 8 SE L A G R A N T P K W Y SE ASHWORTH R D 10' ELEC EASEMENT BK 2015 PG17280 EX FIRE DEPARTMENT CONNECTION W 12 " W12 " W12 " W12 " W12 " W12 " W12 " W 12 " W12 " W 12 " W12 " W12 " W12 " ST 15 " ST 15 " ST 15 " ST 15 " 1018 101 710 1 8 10 1 9 D ST 15" HY D SAWCUT AND REMOVE PAVEMENT SAWCUT AND REMOVE PAVEMENT TO NEAREST JOINT SAWCUT AND REMOVE PAVEMENT TO JOINT SAWCUT AND REMOVE PAVEMENT TO JOINT REMOVE INTAKE REMOVE INTAKE REMOVE INTAKE RELOCATE EX ELECTRIC HANDHOLE (REF ELEC PLANS) RELOCATE EX SIGN RELOCATE EX SIGN REMOVE INTAKE PROTECT & CLEAN OUT EX INLET & OUTLET PIPES REMOVE INTAKE PROTECT OUTLET PIPE REMOVE AND SALVAGE HYDRANT REMOVE INTAKE REMOVE WATER VALVE REMOVE EX STORM SEWER REMOVE TREE (TYP) REMOVE TREE (TYP) REF ELEC PLANS FOR EXISTING BOLLARD LIGHTS, TYP REMOVE EX STORM SEWER TO NEW CONNECTION POINT (REF UTILITY PLAN) REMOVE EX SIDEWALK REMOVE EX STORM SEWER SAWCUT AND REMOVE PAVEMENT TO NEAREST JOINT REMOVE EX SHRUBS AS NECESSARY PROTECT EX STOOP PROTECT EX STOOP PROTECT EX STOOP REMOVE EX STOOP REMOVE TREE (TYP) REMOVE EX STORM SEWER PROTECT EX TREE W/ ORANGE CONSTRUCTION FENCE RELOCATE EX LIGHT POLE (REF ELEC) RELOCATE EX LIGHT POLE (REF ELEC) RELOCATE EX LIGHT POLE (REF ELEC) REF ELEC PLANS FOR EXISTING BOLLARD LIGHTS, TYP REF ELEC PLANS FOR EXISTING BOLLARD LIGHTS, TYP SAWCUT AND REMOVE PAVEMENT TO NEAREST JOINT SAWCUT AND REMOVE PAVEMENT TO JOINT DEMO NOTES: 1.SAWCUT & REMOVE ALL PAVEMENT TO FULL DEPTH OF SLAB. 2.PROTECT ALL TREES NOT CALLED OUT FOR REMOVAL WITH ORANGE CONSTRUCTION FENCE AT THE DRIP LINE. 3.PAVEMENT STRIPING CALLED OUT FOR REMOVAL SHALL BE SANDBLASTED. NO GRINDING WILL BE ALLOWED. PLANNING ARCHITECTUREINTERIORS OWNER SIGN-OFF: REVISIONS: DATE NAME CONSULTANT: 303 Watson Powell Jr. Way Suite 200 Des Moines, Iowa 50309 515.633.2941 515.633.2942 Fax www.invisionarch.com Copyright C 2022 SHEET NAME: PROJECT NO: DATE: SHEET SET: SHEET: PRELIMINARY NOT FOR CONSTRUCTION BISHOP ENGINEERING COMPANY, INC IMEG CORP IMEG CORP CIVIL STRUCTURAL MEP 08.23.2022 21209 WI L C x 29 5 S E A S H W O R T H R O A D W A U K E E , I A 5 0 2 6 3 WA U K E E C O M M U N I T Y S C H O O L D I S T R I C T 3RD CITY SUBMITTAL Description Date No. L: \ L A N D P R O J E C T S 2 0 2 2 \ 2 2 0 0 6 1 W A U K E E W I L C E X P A N S I O N \ D W G \ C 1 D E M O . D W G 8/ 2 3 / 2 0 2 2 1 1 : 2 9 : 4 3 AM Bi s h o p E n g i n e e r i n g GRAPHIC SCALE 020 10 20 40 SITE DEMOLITION PLAN C1.1 SAN SAN SAN SAN SAN SAN SA N SAN . S T ST ST ST ST D D WILCx BUILDING ADDITION FOOTPRINT = 18,636 MAX HEIGHT = 27'-6" FF=1019.04 H Y D WV S S ST 9' R5' R 5 0 ' R 5 6 ' 12' 12' 1 8 ' 2 4 ' 6'6' R5'R 5 ' 5 TAPER CURB OVER 5' TAPER OUT CURB STRUCTURAL STOOP (REF ARCH) TYPE 1 PAVEMENT TYP E 1 P A V E M E N T 5" PCC WALK 5" PCC WALK 5" PCC TURNED DOWN WALK 5" P C C W A L K TY P E 1 P A V E M E N T TYPE 1 PAVEMENT CURB & GUTTER SECTION TYPE 1 PAVEMENT CURB & GUTTER SECTION TYPE 1 PAVEMENT REINSTALL EX SIGN REINSTALL EX SIGN SPEED TABLE (SEE DETAIL 11/C6.1) 5' CENTER 5' WIDE PAINTED ISLAND ON EXISITNG FIRE DEPARTMENT CONNECTION TAPER OUT CURB CON C R E T E P A V E R S CON C R E T E P A V E R S CON C R E T E P A V E R S STRUCTURAL STOOP (REF ARCH) STRUCTURAL STOOP (REF ARCH) D 143. 5 ' 2 9 . 0 ' 30.9 ' 4 8 . 9 ' 1 6 . 1 ' 64 . 6 ' 9 3 . 3 6 ' 104.8' 6 5 . 1 ' 31.1 ' 2 9 . 0 ' 0.3' CO CP #89022 CP #9901 F F = 1 0 1 9 . 0 4 F F = 1 0 1 9 . 0 4 CO CO CO EP S WV H Y D H Y D WV SD D S ST 15" ST 15" ST 15" ST 15" ST 15" ST 15" ST 15" S T S T S T S T S T ST 15 " ST 15 " ST 15"ST 15"ST 15" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W8"W8"W8"W8"W8"W8"W8"W8"W8"W8"W8"W8" W6" EXTISTING BUILDING FOOTPRINT = 35,770 SF FF = 1019.04 EX TRASH ENCLOSURE EX. COLUMN FOR SECOND FLOOR OVERHANG EX WALL EX CONCRETE EX CONCRETE EX CONCRETE EX CONCRETE EX BOLLARD (TYPICAL) SAN 6" SA N 8 " F/O F/O F/O F/ O F/ O F/ O F/ O F/ O F/ O F/ O ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6" ST 6" SA N 6" SAN 6" SA N 10 " SA N 10 " 3" TREE3" TREE 3" TREE 3" TREE 3" TREE 3" TREE EX CONCRETE EX C O L O R E D C O N C R E T E 36" TREE 18" TREE 18" PINE 24" PINE24" PINE12" PINE 6" TREE 18" TREE 8" TREE 12" PINE 6" TREE6" TREE 6" TREE 48" TREE 36" TREE 18" PINE 24" PINE 18" PINE12" PINE24" PINE6" TREE24" PINE24" PINE 24" PINE24" PINE24" PINE 8" TREE 8" TREE12" TREE 8" TREE 12" TREE 36" TREE S FUTURE TRAIL EA S E M E N T SA N S W R E A S E M E N T B K 2 0 1 4 P G 6 0 8 8 10 ' P . U . E . B K 2 0 1 3 P G 2 1 2 9 6 10' P.U.E. BK 2013 P G 2 1 2 9 6 10' P.U.E. BK 2013 P G 2 1 2 9 6 10 ' P . U . E . B K 2 0 1 3 P G 2 1 2 9 6 SA N S W R E A S E M E N T B K 2 0 1 4 P G 6 0 8 8 SE L A G R A N T P K W Y SE ASHWORTH R D 10' ELEC EASEMENT BK 2015 PG17280 W 12 " W12 " W12 " W12 " W12 " W12 " W12 " W12 " W12 " W 12 " W12 " W12 " W12 " ST 15 " ST 15 " ST 15 " ST 15 " D ST 15" H Y D PLANNING ARCHITECTUREINTERIORS OWNER SIGN-OFF: REVISIONS: DATE NAME CONSULTANT: 303 Watson Powell Jr. Way Suite 200 Des Moines, Iowa 50309 515.633.2941 515.633.2942 Fax www.invisionarch.com Copyright C 2022 SHEET NAME: PROJECT NO: DATE: SHEET SET: SHEET: PRELIMINARY NOT FOR CONSTRUCTION BISHOP ENGINEERING COMPANY, INC IMEG CORP IMEG CORP CIVIL STRUCTURAL MEP 08.23.2022 21209 WI L C x 29 5 S E A S H W O R T H R O A D W A U K E E , I A 5 0 2 6 3 WA U K E E C O M M U N I T Y S C H O O L D I S T R I C T 3RD CITY SUBMITTAL Description Date No. L: \ L A N D P R O J E C T S 2 0 2 2 \ 2 2 0 0 6 1 W A U K E E W I L C E X P A N S I O N \ D W G \ C 2 L A Y O U T . D W G 8/ 2 3 / 2 0 2 2 1 1 : 3 3 : 2 9 AM Bi s h o p E n g i n e e r i n g GRAPHIC SCALE 020 10 20 40 SITE LAYOUT PLAN C2.1 CP #89022 CP #9901 F F = 1 0 1 9 . 0 4 F F = 1 0 1 9 . 0 4 CO CO CO EP S WV H Y D H Y D WV SD D S ST 15" ST 15" ST 15" ST 15" ST 15" ST 15" ST 15" S T S T S T S T S T ST 15 " ST 15 " ST 15"ST 15"ST 15" W8" W8" W8" W 8" W 8" W 8" W 8" W 8" W 8" W8"W8"W8"W8"W8"W8"W8"W8"W8"W8"W8"W8" W6" EXTISTING BUILDING FOOTPRINT = 35,770 SF FF = 1019.04 EX TRASH ENCLOSURE 1022 1021 10 1 8 101 9 1019 1018 1020 1019 1 0 1 7 1 0 1 6 1 0 1 5 1 0 1 8 101 7 1016 1017 1 0 1 7 101 6 1015 1014 10 1 3 1 0 1 8 1 0 1 6 1 0 1 5 1 0 1 4 101 8 1018 1018 1019 101 9 EX. COLUMN FOR SECOND FLOOR OVERHANG EX WALL EX CONCRETE EX CONCRETE EX CONCRETE EX CONCRETE EX BOLLARD (TYPICAL) SAN 6" SA N 8 " F/O F/O F/O F/ O F/ O F/ O F/ O F/ O F/ O F/ O ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6" ST 6" SA N 6" SAN 6" SA N 10 " SA N 10 " EX CONCRETE EX C O L O R E D C O N C R E T E S FUTURE TRAIL EA S E M E N T SA N S W R E A S E M E N T B K 2 0 1 4 P G 6 0 8 8 10 ' P . U . E . B K 2 0 1 3 P G 2 1 2 9 6 10' P.U.E. BK 2013 P G 2 1 2 9 6 10' P.U.E. BK 2013 P G 2 1 2 9 6 10 ' P . U . E . B K 2 0 1 3 P G 2 1 2 9 6 SA N S W R E A S E M E N T B K 2 0 1 4 P G 6 0 8 8 SE L A G R A N T P K W Y SE ASHWORTH R D 10' ELEC EASEMENT BK 2015 PG17280 W 12 " W12 " W12 " W12 " W12 " W12 " W12 " W12 " W12 " W12 " W12 " W12 " W12 " ST 15 " ST 15 " ST 15 " ST 15 " 1018 101 710 1 8 10 1 9 D ST 15" H Y D SAN SAN SAN SAN SAN SAN SA N SAN . S T ST ST ST ST D D WILCx BUILDING ADDITION FOOTPRINT = 18,636 MAX HEIGHT = 27'-6" FF=1019.04 H Y D WV S S ST 5.1% 1. 5 % 1. 1 % 1 0 1 8 1 0 1 9 1019 1019 1019 1018 1019.04 1019.04 1019.04 1019.04 1018.95 1019.04 1018.95 1018.61 1018.70 1018.61 1018.70 OVERTOPPING 1018.80 1018.71 1018.00 1018.93 1019.04 1019.04 1019.04 1018.95 1019.04 1018.95 1019.04 1018.95 1018.95 1018.87T/C 1018.37G 1018.80T/C 1018.30G 1018.30T/C 1017.80G 1018.56T/C 1018.06G 1018.90T/C 1018.40G 1018.30T/C 1017.80G 1018.77T/C 1018.27G OVERTOPPING 1018.64 EX 1018.66 EX 1018.81 EX 1019.02 EX 1018.53 1019.04 1019.04 1018.95 1018.95 1018.95 1019.03 1019.03 1018.25 1019.17T/C 1018.67G 1018.83T/C 1018.33±G EX 1018.82T/C 1018.32G 1018.45T/C 1017.95G 1018.45T/C 1017.95G 1018.07± EX 1017.95± EX 1017.68± EX 1017.40± EX 1017.47± EX 1017.75± EX 1017.91± EX 1018.23± EX 1018.63 1018.43± EX 1018.42± EX 1018.92± EX 1018.98± EX 1018.96 EX 1018.55 1018.62G± EX 1019.17T/C± EX 1018.74 1018.46T/C 1017.96G 1018.64 1018.80 1018.48T/C 1017.98G OVERTOPPING1018.40T/C 1017.90G 1018.80T/C 1018.30G 1018.34 1019.02T/C EX 1018.52G EX 1018.04 EX 1018.78T/C 1018.28G 1018.78 1018.90 OVERTOPPING 1019.15 1019.271019.15T/C 1018.65G 1019.27T/C 1018.77G 1017.95G 1018.22± EX 1018.25 1018.80 1018.80 1018.55 1018.48 1018.80 1019.04 1018.95 1018.94 1018.96 1018.83 1018.95 1018.95 EX 1019 1 0 1 9 1019.04 1019.04 1019.04 1019.04 1019.04 1019.04 1019.04 1019.04 1019.04 1019.04 1019.04 1019.04 1019.04 1019.04 1019.04 1019.04 1019.04 1019.04 1019.04 1019.04 1019.04 1018.98 EX 1018.95 EX 1018.93 1018.94 1018.94 1018.92 1018.93 EX 1018.94 EX 1018.94 EX 1018.94 EX 1018.95 EX 1018.96 EX 1018.97 EX 1018.91 EX 1018.86 EX 1018.94 EX 1018.84 EX 1019.04 1019.04 1019.04 1019.04 1018.96 1018.96 1018.96 1018.96 1018.961018.96 1018.96 1018.96 1018.961018.96 1018.96 1018.96 1018.961018.96 1018.96 1018.96 1019.01 1018.98 1018.78 1018.84 1018.92 1018.82 OVERTOPPING 1018.87 1018.84 1018.79 1018.85 OVERTOPPING 1018.88 1018.85 1018.79 1018.85 OVERTOPPING 1018.89 1018.85 1018.79 1018.86 D1018.87 1018.94 1019.04 1019.04 6. 3 % 10 . 2 % 7. 9 % 2. 1 % 4.3% 2.4% 2.0% 2.1% 2.5 % 3.5% 100-YR PONDING ELEV=1018.28 100-YR PONDING ELEV=1018.03 100-YR PONDING ELEV=1017.98 100-YR PONDING ELEV=1018.21 100-YR PONDING ELEV=1018.28 100-YR PONDING ELEV=1018.84 100-YR PONDING ELEV=1018.84 100-YR PONDING ELEV=1018.84 100-YR PONDING ELEV=1018.84 1.3 % 1.5% 1. 5 % 1. 5 % 1. 5 % 1. 5 % 1 . 5 % 1 . 5 % 1.0% 1.5% 1.5% 1.0% 1. 3 % 0 . 2 % 1.3% 1.1% 1.5% 1.8% 1018.33± EX 1018.39 1018.63 1018.20T/C TAPER OUT CURB HEIGHT 1.5% 1.5% 1 . 5 % 1 . 5 % 0.5% 0.9 % 2.6% 1.6% 1 . 6 % 0 . 6 % 0. 0 % 0. 0 % 1.7 % 0 . 8 % 0.1% 0 . 1 % CO 1019.16T/C 1018.66G 1018.88T/C 1018.38G TOPSOIL NOTES: 1.STRIP AND STOCKPILE THE TOP 8" OF SOIL ON ALL DISTURBED AREAS. 2.RESPREAD TOPSOIL TO A MINIMUM DEPTH OF 8" ON ALL GREEN (NON PAVED) AREAS. IMPORT TOPSOIL AS NECESSARY TO ACHIEVE A MINIMUM DEPTH OF 6". 3.TOPSOIL SHALL BE FREE OF ALL ROCK AND DEBRIS LARGER THAN 3/4" IN SIZE. 4.TOPSOIL IS DEFINED AS: FERTILE, FRIABLE LOAM, CAPABLE OF SUSTAINING VIGOROUS PLANT GROWTH, FROM WELL DRAINED SITE FREE FROM FLOODING, NOT IN FROZEN OR MUDDY CONDITIONS; REASONABLE FREE FROM SUBSOIL, CLAY LUMPS, ROOTS, GRASS, WEEDS, STONES LARGER THAN 3/4 INCH IN DIAMETER, AND FOREIGN MATTER; ACIDITY RANGE (PH) OF 5.5 TO 7.5; CONTAINING MINIMUM 4 PERCENT AND MAXIMUM 20 PERCENT ORGANIC MATTER. 5.CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING ALL TOPSOIL REQUIREMENTS OF NPDES GENERAL PERMIT NO. 2 ARE MET. PLANNING ARCHITECTUREINTERIORS OWNER SIGN-OFF: REVISIONS: DATE NAME CONSULTANT: 303 Watson Powell Jr. Way Suite 200 Des Moines, Iowa 50309 515.633.2941 515.633.2942 Fax www.invisionarch.com Copyright C 2022 SHEET NAME: PROJECT NO: DATE: SHEET SET: SHEET: PRELIMINARY NOT FOR CONSTRUCTION BISHOP ENGINEERING COMPANY, INC IMEG CORP IMEG CORP CIVIL STRUCTURAL MEP 08.23.2022 21209 WI L C x 29 5 S E A S H W O R T H R O A D W A U K E E , I A 5 0 2 6 3 WA U K E E C O M M U N I T Y S C H O O L D I S T R I C T 3RD CITY SUBMITTAL Description Date No. L: \ L A N D P R O J E C T S 2 0 2 2 \ 2 2 0 0 6 1 W A U K E E W I L C E X P A N S I O N \ D W G \ C 3 G R A D I N G . D W G 8/ 2 3 / 2 0 2 2 1 1 : 3 6 : 2 8 AM Bi s h o p E n g i n e e r i n g GRADING LEGEND: EXISTING CONTOUR PROPOSED CONTOUR FINISHED GROUND ELEVATION TOP OF CURB ELEVATION GUTTER ELEVATION TOP OF WALL ELEVATION BOTTOM OF WALL ELEVATION EDGE OF WALK ELEVATION TOP OF STAIR ELEVATION BOTTOM OF STAIR ELEVATION NOTE: WALL ELEVATIONS SHOWN ON PLAN ARE FINISHED GROUND GRADES AT THE TOP AND BOTTOM OF THE WALL. 150.50E/W 150.50B/W 150.50T/W 150.50G 150.50T/C 150.50 150 150 150.50T/S 150.50B/S GRAPHIC SCALE 020 10 20 40 GRADING PLAN C3.1 SAN SAN SAN SAN SAN SAN SA N SAN . S T ST ST ST ST D D WILCx BUILDING ADDITION FOOTPRINT = 18,636 MAX HEIGHT = 27'-6" FF=1019.04 H Y D WV S S REMOVE & REPLACE 8" WATER AS NECESSARY TO LOWER UNDER SAN ST CONNECT TO EX HYDRANT LEAD & EXTEND 18LF INSTALL RELOCATED HYDRANT ASSEMBLY SW-301 MANHOLE RIM=1020.00 INV(W)=1014.00 INV(S)=1012.57 INV(NE)=1012.47 174LF 6" SAN @ S=1.00% SW-301 MANHOLE RIM=1020.00 INV(SW)=1010.73 INV(SE)=1010.63 CORE DRILL CONNECTION TO EX MANHOLE INV(NW)=1010.26 37LF 6" SAN @ S=1.00% 38LF 6" SAN @ S=1.00% INV=1012.95 (REF PLUMB) *CRITICAL CROSSING* BOTTOM SAN=1012.60± TOP WATER=1011.00± *CRITICAL CROSSING* BOTTOM STORM=1015.00± TOP SAN=1013.50± STRUCTURE #29A INSTALL SW-501 INTAKE W/ SW-603 TYPE R CASTING OVER EX PIPE T/C=1018.30 FL(E)=1015.00 FL(W)=1011.73 EX INSTALL INSERTA-TEE CONNECTION TO EX PIPE FL(E,W)=1010.10± FL(S)=1011.35 STRUCTURE #29 INSTALL SW-501 INTAKE W/ SW-603 TYPE R CASTING OVER EX PIPE T/C=1018.30 FL(E)=1010.64± (VERIFY) FL(W)=1010.54± (VERIFY) 7LF 6" N-12 @ S=5.00% STRUCTURE #29C 18" NYLOPLAST BASIN W/ FLAT GRATE RIM=1017.75 FL(S)=1011.80 FL(N)=1011.70 STRUCTURE #28Y INSTALL 4' FDHC HYDRODYNAMIC SEPERATOR RIM=1018.53 FL(E)=1009.69 FL(NW)=1009.59± EX 44LF 15" RCP @ S=2.00% STRUCTURE #28Z SW-401 MANHOLE W/ SW-602 TYPE F CASTING RIM=1018.94 FL(NE)=1011.19 FL(NW)=1011.09 REF PLUMBING FOR STORM UNDER BUILDING (INCLUDING CASING PIPE) STRUCTURE #28A SW-401 MANHOLE W/ PEDESTRIAN GRATE RIM=1018.78 FL(NE)=1012.65 FL(SW)=1012.55 30LF 10" N-12 @ S=2.00% STRUCTURE #28B 24" NYLOPLAST BASIN W/ PEDESTRIAN GRATE RIM=1018.79 FL(NE)=1013.35 FL(SW)=1013.25 30LF 10" N-12 @ S=1.00% STRUCTURE # 28C 24" NYLOPLAST BASIN W/ PEDESTRIAN GRATE RIM=1018.79 FL(NE)=1014.05 FL(SW)=1013.95 30LF 10" N-12 @ S=1.00% STRUCTURE # 28D 24" NYLOPLAST BASIN W/ PEDESTRIAN GRATE RIM=1018.79 FL(SW)=1014.65 3LF 10" N-12 @ S=5.00% FL=1010.97 (REF PLUMB) 34LF 6" N-12 @ S=1.00% STRUCTURE #29B 18" NYLOPLAST BASIN W/ FLAT GRATE RIM=1018.25 FL(W)=1015.34 RELOCATED LIGHT POLE (REF ELECTRICAL) RELOCATED LIGHT POLE (REF ELECTRICAL) RELOCATED LIGHT POLE (REF ELECTRICAL) STRUCTURE #29D 18" NYLOPLAST BASIN W/ FLAT GRATE RIM=1018.25 FL(N)=1013.00 24LF 6" N-12 @ S=5.00% D 21LF 15" RCP @ S=2.00% STRUCTURE #28 SW-401 MANHOLE W/ SW-602 TYPE F CASTING RIM=1018.87 FL(NE)=1010.82 FL(SE)=1010.67 FL(NW)=1010.57 R 1 5 0 ' H Y D R A N T R A D I U S , T Y P 3LF 15" SCH 40 PVC @ S=2.00% 24LF 15" SCH 40 PVC @ S=2.00% 39LF 4" SAN @ S=2.00% 19LF 4" SAN @ S=2.00% SAND/OIL LINE (REF PLUMB) SAND/OIL SEPERATOR (REF PLUMB) CLEANOUT INV=1014.78 CO *CRITICAL CROSSING* BOTTOM SAN=1015.00± TOP WATER=1012.80± CP #89022 CP #9901 F F = 1 0 1 9 . 0 4 F F = 1 0 1 9 . 0 4 CO CO CO EP S EX SAN MH RIM=1017.62 TOP OF CO=1014.40 BOTTOM STRUCTURE=1008.40 WV H Y D TBM: BURY BOLT ELEV=1020.13 H Y D TBM: BURY BOLT ELEV=1017.69 WV S EX SAN MH RIM=1017.57 TOP OF CO= 1014.25 BOTTOM STRUCTURE=1008.25D EX STORM MH RIM=1017.46 INV E=1009.34 INV S=1008.96 D EX STORM MH RIM=1016.50 INV N=1008.05 INV SE=1008.00 INV W=1007.90 S EX SAN MH RIM=1016.93 FL(N)=1010.93 ST 15" ST 15" ST 15" ST 15" ST 15" ST 15" ST 15" S T S T S T S T S T ST 15 " ST 15 " ST 15"ST 15"ST 15" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W8"W8"W8"W8"W8"W8"W8"W8"W8"W8"W8"W8" W6" EXTISTING BUILDING FOOTPRINT = 35,770 SF FF = 1019.04 EX TRASH ENCLOSURE EX. COLUMN FOR SECOND FLOOR OVERHANG EX WALL EX CONCRETE EX CONCRETE EX CONCRETE EX CONCRETE EX BOLLARD (TYPICAL) SAN 6" SA N 8 " F/O F/O F/O F/ O F/ O F/ O F/ O F/ O APPROXIMATE LOCATION PER WAUKEE COMMUNITY SCHOOLS MAP F/ O F/ O ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6" ST 6" SA N 6" SAN 6" SA N 10 " SA N 10 " EX CONCRETE EX C O L O R E D C O N C R E T E S EX SAN MH RIM=1020.06 FL(N)=1010.01 FL(S)=1010.11 FUTURE TRAIL EA S E M E N T SA N S W R E A S E M E N T B K 2 0 1 4 P G 6 0 8 8 10 ' P . U . E . B K 2 0 1 3 P G 2 1 2 9 6 10' P.U.E. BK 2013 P G 2 1 2 9 6 10' P.U.E. BK 2013 P G 2 1 2 9 6 10 ' P . U . E . B K 2 0 1 3 P G 2 1 2 9 6 SA N S W R E A S E M E N T B K 2 0 1 4 P G 6 0 8 8 SE L A G R A N T P K W Y SE ASHWORTH R D 10' ELEC EASEMENT BK 2015 PG17280 EX FIRE DEPARTMENT CONNECTION W 12 " W12 " W12 " W12 " W12 " W12 " W12 " W12 " W12 " W12 " W12 " W12 " W12 " ST 15 " ST 15 " ST 15 " ST 15 " D ST 15" HY D ADJUST RIM ELEVATION TO 1002.00 & INSTALL FLAT GRATE. INSTALL WEIR WALL IN EXISTING MANHOLE (SEE DETAIL 10/C6.1) EXISTING 20' WIDE EMERGENCY OVERFLOW LOCATION 20' CP #9902 D EX STORM MH RIM=1000.50 INV N=992.60 INV S=992.55 WITH RESTRICTER PLAT EX 24" CPP FES FL=993.67 EX 24" CPP FES FL=996.10 995 996 997 998 999 1000 1 0 0 1 1 0 0 2 1 0 0 3 1 0 0 4 1 0 0 5 995996 997 998 999 1001 1002 1003 1003 1002 1001 1000 996 997 998 999 1001 99 6 99 7 99 8 99 9 10 0 0 10 0 1 10 0 2 ST 15 " UTILITY NOTES: 1.ALL PROPOSED UTILTIES SHALL BE PRIVATE, UNLESS NOTED OTHERWISE. 2.ALL WATER LINES SHALL HAVE A MINIMUM OF 5.5' OF COVER UNLESS NOTED OTHERWISE. 3.FIRE HYDRANT ASSEMBLY SHALL INCLUDE THE TEE, BRANCH, VALVE AND HYDRANT. 4.PIPE LENGTHS CALLED OUT ON PLANS INCLUDE FLARED END SECTION, WHERE APPLICABLE. 5.STORM SEWER CALLED OUT AS RCP MUST BE CLASS III RCP. 6.STORM SEWER CALLED OUT AS N-12 MAY BE EITHER N-12 OR CLASS III RCP. 7.FOR RCP PIPE, ASSOCIATED F.E.S. MUST BE RCP. FOR N-12 PIPE, ASSOCIATED F.E.S. SHALL BE CMP. 8.ALL NYLOPLAST BASINS SHALL HAVE CASTINGS SECURELY FASTENED TO THE BASIN BODY, AND ALL GRATES/LIDS SHALL BE BOLTED DOWN TO THE CASTINGS. PLANNING ARCHITECTUREINTERIORS OWNER SIGN-OFF: REVISIONS: DATE NAME CONSULTANT: 303 Watson Powell Jr. Way Suite 200 Des Moines, Iowa 50309 515.633.2941 515.633.2942 Fax www.invisionarch.com Copyright C 2022 SHEET NAME: PROJECT NO: DATE: SHEET SET: SHEET: PRELIMINARY NOT FOR CONSTRUCTION BISHOP ENGINEERING COMPANY, INC IMEG CORP IMEG CORP CIVIL STRUCTURAL MEP 08.23.2022 21209 WI L C x 29 5 S E A S H W O R T H R O A D W A U K E E , I A 5 0 2 6 3 WA U K E E C O M M U N I T Y S C H O O L D I S T R I C T 3RD CITY SUBMITTAL Description Date No. L: \ L A N D P R O J E C T S 2 0 2 2 \ 2 2 0 0 6 1 W A U K E E W I L C E X P A N S I O N \ D W G \ C 4 U T I L I T Y . D W G 8/ 2 3 / 2 0 2 2 1 1 : 3 9 : 2 1 AM Bi s h o p E n g i n e e r i n g GRAPHIC SCALE 020 10 20 40 UTILITY PLAN C4.1 DETENTION BASIN MODIFICATION PLAN: SCALE: 1" = 20' SAN SAN SAN SAN SAN SAN SA N SAN . S T ST ST ST ST D D WILCx BUILDING ADDITION FOOTPRINT = 18,636 MAX HEIGHT = 27'-6" FF=1019.04 HY D WV S S ST 1 0 1 8 1 0 1 9 1019 1019 1019 1018 1019 1 0 1 9 D CO CP #89022 CP #9901 F F = 1 0 1 9 . 0 4 F F = 1 0 1 9 . 0 4 CO CO CO EP S WV H Y D H Y D WV SD D S ST 15" ST 15" ST 15" ST 15" ST 15" ST 15" ST 15" S T S T S T S T ST 15 " ST 15 " ST 15"ST 15"ST 15" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W8"W8"W8"W8"W8"W8"W8"W8"W8"W8"W8"W8" W6" EXTISTING BUILDING FOOTPRINT = 35,770 SF FF = 1019.04 EX TRASH ENCLOSURE 1022 1021 10 1 8 101 9 1019 1018 1020 1019 1 0 1 7 1 0 1 6 1 0 1 5 1 0 1 8 101 7 1016 1017 1 0 1 7 101 6 1015 1014 10 1 3 1 0 1 8 1 0 1 6 1 0 1 5 1 0 1 4 101 8 1018 1018 1019 101 9 EX. COLUMN FOR SECOND FLOOR OVERHANG EX WALL EX CONCRETE EX CONCRETE EX CONCRETE EX CONCRETE EX BOLLARD (TYPICAL) SAN 6" SA N 8 " F/O F/O F/O F/ O F/ O F/ O F/ O F/ O F/ O F/ O ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6" ST 6" SA N 6" SAN 6" SA N 10 " 3" TREE3" TREE 3" TREE 3" TREE 3" TREE 3" TREE EX CONCRETE EX C O L O R E D C O N C R E T E 36" TREE 18" TREE 18" PINE 24" PINE24" PINE12" PINE 6" TREE 18" TREE 8" TREE 12" PINE 6" TREE6" TREE 6" TREE 48" TREE 36" TREE 18" PINE 24" PINE 18" PINE12" PINE24" PINE6" TREE24" PINE24" PINE 24" PINE24" PINE24" PINE 8" TREE 8" TREE12" TREE 8" TREE 12" TREE 36" TREE S FUTURE TRAIL EA S E M E N T SA N S W R E A S E M E N T B K 2 0 1 4 P G 6 0 8 8 10 ' P . U . E . B K 2 0 1 3 P G 2 1 2 9 6 10' P.U.E. BK 2013 P G 2 1 2 9 6 10' P.U.E. BK 2013 P G 2 1 2 9 6 SA N S W R E A S E M E N T B K 2 0 1 4 P G 6 0 8 8 SE L A G R A N T P K W Y SE ASHWORTH R D 10' ELEC EASEMENT BK 2015 PG17280 W 12 " W12 " W12 " W12 " W12 " W12 " W 12 " W 12 " W12 " W12 " W12 " W12 " W12 " ST 15 " ST 15 " ST 15 " ST 15 " 1018 101 710 1 8 10 1 9 D ST 15" H Y D ALL COURTYARD LANDSCAPE AREAS TO BE DESIGNED & INSTALLED BY OWNER, TYP SOD SODSODSOD SOD SOD SOD SOD SOD SOD EDGING EDGING WR 14 WR 2 D 995996 997 998 999 1001 1002 1003 1003 1002 1001 1000 99 6 99 7 99 8 99 9 10 0 0 10 0 1 10 0 2 ST 15 " SOD ALL DISTURBED AREA FROM DETENTION BASIN MODIFICATIONS PLANNING ARCHITECTUREINTERIORS OWNER SIGN-OFF: REVISIONS: DATE NAME CONSULTANT: 303 Watson Powell Jr. Way Suite 200 Des Moines, Iowa 50309 515.633.2941 515.633.2942 Fax www.invisionarch.com Copyright C 2022 SHEET NAME: PROJECT NO: DATE: SHEET SET: SHEET: PRELIMINARY NOT FOR CONSTRUCTION BISHOP ENGINEERING COMPANY, INC IMEG CORP IMEG CORP CIVIL STRUCTURAL MEP 08.23.2022 21209 WI L C x 29 5 S E A S H W O R T H R O A D W A U K E E , I A 5 0 2 6 3 WA U K E E C O M M U N I T Y S C H O O L D I S T R I C T 3RD CITY SUBMITTAL Description Date No. L: \ L A N D P R O J E C T S 2 0 2 2 \ 2 2 0 0 6 1 W A U K E E W I L C E X P A N S I O N \ D W G \ C 5 L A N D S C A P E . D W G 8/ 2 3 / 2 0 2 2 1 1 : 4 2 : 1 9 AM Bi s h o p E n g i n e e r i n g LEGEND SOD: PROVIDE AND INSTALL SOD FROM LOCAL SUPPLIERS. AREAS TO BE SODDED MUST BE FREE OF ALL CONSTRUCTION DEBRIS AND ANY DIRT CLUMPS OVER 1" IN DIAMETER. THOROUGHLY WATER SOD UPON INSTALLATION. CONTRACTOR TO MAINTAIN WATERING UNTIL SOD IS ESTABLISHED (ROOTS KNITTED INTO SUBSURFACE) GRAPHIC SCALE 020 10 20 40 LANDSCAPE PLAN C5.1 LANDSCAPE CALCULATIONS: NOTE: GENERAL PROVISIONS FOR C-1 DISTRICT ARE USED FOR OPEN SPACE AND LANDSCAPING REQUIREMENTS OPEN SPACE REQUIREMENTS: TOTAL PROJECT SITE AREA 531,200 SF (12.19 ACRES) OPEN SPACE REQUIRED 106,240 SF (20%) BUILDING AREA 54,400 SF PAVEMENT AREA 173,600 SF TOTAL IMPERVIOUS SURFACE 228,000 SF TOTAL OPEN SPACE PROVIDED 303,200 SF LANDSCAPING REQUIREMENTS: ONE TREE AND ONE SHRUB PER 1000 SF OF OPEN SPACE REQUIRED TREES REQUIRED = 106,240 / 1,000 =107 TREES REQUIRED SHRUBS REQUIRED = 106,240 / 1,000 = 107 SHRUBS REQUIRED EXISTING WOODED AREA TREES (MAX OF 50%)53 TREES EXISTING ON LANDSCAPE TREES 77 TREES EXISTING TREES REMOVED 9 TREES TOTAL TREES PROVIDED 121 TREES EXISTING SHRUBS PROVIDED 107 SHRUBS SHRUBS REMOVED 9 SHRUBS SHRUBS ADDED 16 SHRUBS TOTAL SHRUBS PROVIDED 114 SHRUBS DETENTION BASIN AREA SCALE: 1" = 20' LANDSCAPE NOTES: 1.ALL SODDING & LANDSCAPE PLANTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, UNLESS SPECIFIED OTHERWISE. 2.SOD ALL DISTURBED AREAS WITHIN THE CONTRACT LIMITS, UNLESS NOTED OTHERWISE. SOD LIMITS SHOWN ON PLAN ARE FOR REFERENCE ONLY. FINAL LIMITS MAY CHANGE BASED ON CONSTRUCTION ACTIVITIES. 3.STAKE SOD ON ALL SLOPES 4 : 1 OR GREATER. 4.PLANT QUANTITIES ARE FOR CONTRACTORS CONVENIENCE, THE DRAWING SHALL PREVAIL IF A CONFLICT OCCURS. 5.ALL PLANT MATERIAL SHALL CONFORM TO THE LATEST EDITION OF THE AMERICAN STANDARD FOR NURSERY STOCK (ANSI Z60.1). 6.CONTRACTOR SHALL GUARANTEE ALL PLANT MATERIAL FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE. 7.IT IS THE CONTRACTORS RESPONSIBILITY TO REMOVE IDENTIFICATION TAGS AND CORDS ON ALL PLANT MATERIAL PRIOR TO THE COMPLETION OF THE CONTRACT. IDENTIFICATION TAGS MUST BE LEFT ON UNTIL AFTER ACCEPTANCE BY OWNER OR OWNER'S REPRESENTATIVE. 8.CONTRACTOR SHALL PLACE SHREDDED HARDWOOD MULCH AROUND ALL TREES, SHRUBS AND GROUND COVER BEDS TO A DEPTH OF 4 INCHES, UNLESS NOTED. 9.STAKE AND WRAP ALL DECIDUOUS TREES IMMEDIATELY AFTER PLANTING. STAKE ALL TREES ACCORDING TO THE STAKING DETAILS. CONTRACTOR SHALL ADJUST AND MAINTAIN GUYING TENSION THROUGHOUT THE PLANT ESTABLISHMENT PERIOD. 10.THE LANDSCAPING CONTRACTOR SHALL HAVE ALL UTILITIES LOCATED BEFORE STARTING ANY SITE WORK OR PLANTING. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING UTILITIES. 11.NO LANDSCAPE MATERIAL SHALL BE SUBSTITUTED WITHOUT THE AUTHORIZATION OF THE LANDSCAPE ARCHITECT. ANY SUBSTITUTIONS SHALL BE APPROVED IN WRITING BY THE CITY. 12.CONTRACTOR SHALL BE RESPONSIBLE MAINTAINING APPROPRIATE LEVEL OF WATERING FOR ALL NEW PLANTS UNTIL ACCEPTED BY OWNER. 13.ALL SHRUB AND PERENNIAL PLANTING BEDS SHALL BE MULCHED WITH 4" THICK SHREDDED HARDWOOD MULCH UNLESS NOTED. 14.ALL BEDS TO RECEIVE GRANULAR PRE-EMERGENT WEED CONTROL BEFORE AND AFTER MULCH IS INSTALLED. 4.FOR WARRANTY PURPOSES, THE DATE OF INITIAL ACCEPTANCE SHALL BE SUBMITTED IN WRITING TO THE OWNER AND/OR OWNER'S REPRESENTATIVE AFTER ALL PLANT MATERIALS HAVE BEEN INSTALLED AND REVIEWED BY OWNER OR OWNER'S REPRESENTATIVE. PLANT MATERIALS WILL ONLY BE ACCEPTED IF THEY ARE IN AN ALIVE AND THRIVING CONDITION 5.LANDSCAPING INCLUDING SOD MUST BE WATERED UNTIL ACCEPTED BY OWNER DECIDUOUS SHRUB DETAIL EVERGREEN SHRUB DETAIL PLANTING ON SLOPES FIRMLY COMPACT SAUCER (USE TOPSOIL) ORIGINAL GROUND LINE SUB-SOIL 4" MULCH PLANTING PIT TWICE THE WIDTH OF ROOTBALL 1 2 SHRUB PLANTING (TYP) NOT TO SCALESCALE: 3" ROCK PLANTING SCHEDULE PLANNING ARCHITECTUREINTERIORS OWNER SIGN-OFF: REVISIONS: DATE NAME CONSULTANT: 303 Watson Powell Jr. Way Suite 200 Des Moines, Iowa 50309 515.633.2941 515.633.2942 Fax www.invisionarch.com Copyright C 2022 SHEET NAME: PROJECT NO: DATE: SHEET SET: SHEET: PRELIMINARY NOT FOR CONSTRUCTION BISHOP ENGINEERING COMPANY, INC IMEG CORP IMEG CORP CIVIL STRUCTURAL MEP 08.23.2022 21209 WI L C x 29 5 S E A S H W O R T H R O A D W A U K E E , I A 5 0 2 6 3 WA U K E E C O M M U N I T Y S C H O O L D I S T R I C T 3RD CITY SUBMITTAL Description Date No. L: \ L A N D P R O J E C T S 2 0 2 2 \ 2 2 0 0 6 1 W A U K E E W I L C E X P A N S I O N \ D W G \ C 6 D E T A I L S . D W G 8/ 2 3 / 2 0 2 2 1 1 : 4 2 : 5 6 AM Bi s h o p E n g i n e e r i n g SITE DETAILS SHEET C6.1 JOINTING DETAILS SCALE NONE 6 C6.1 BACK OF CURB FACE OF CURB EDGE OF TURNED DOWN WALK SIDEWALK PAVEMENT GRASS/LANDSCAPING ROADWAY PAVEMENT PLAN VIEW CURB & GUTTER / TURNED DOWN WALK TRANSITION DETAIL SCALE NONE 4 C6.1 XXX 36" 2" 5'-0" 12"12" STRUCTURAL STOOP / SIDEWALK TRANSITION DETAIL SCALE NONE 5 C6.1 TURNED DOWN WALK DETAIL SCALE NONE 2 C6.1 5" SLOPE PER PLANS 1.5% MAX CROSS SLOPE ROADWAY PAVEMENT 6" MAX (DIRECTION SHOWN ON GRADING PLANS) VARIES 5/8"RESILIENT JOINT FILLER 1/2" GRAY MASTIC JOINT SEALANT MATERIAL DETAIL A: NOT TO SCALE EDGE WITH 1/4 INCH TOOL FOR LENGTH OF JOINT INDICATED IF FORMED; EDGING NOT REQUIRED WHEN CUT WITH DIAMOND BLADE SAW 1" NOTES: *IMPORTANT:* 1" EXPANSION JOINT BETWEEN ROADWAY PAVEMENT AND WALK MUST BE INSTALLED TO FULL DEPTH OF SLAB. FINISH W/ 3/4" RADIUS TOOL SEALED 'E' JOINT SEE DETAIL A & NOTES 6" 8' LONG #4 BARS 24" O/C BOTH WAYS ALL REINFORCEMENT SHALL BE EPOXY COATED 6" 1" NOMINAL 12"24" MIN SEE PAVEMENT SECTION FOR SUBGRADE INFO 24" 3"4.5" 6" 7" R 1" R 2" NOTES: 1.SLOPE GUTTER IN ACCORDANCE WITH GRADING PLAN. 2.INSTALL CURB & GUTTER INTERGRAL WITH PAVING. 3.PCC PAVEMENT SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 4,000 PSI. TYPE 1 PAVEMENT SECTION SCALE NONEC6.1 1 7" PCC C4 MIX 12" SUBGRADE PREPARATION IN TWO 6" LIFTS COMPACTED BACKFILL 1 2 3 Locate 'DW' joint at a mid-panel location between future 'C' or 'CD' joints. Place no closer than 5 feet to a 'C' or 'CD' joint. Place bars within the limits shown under dowel assemblies. 'RT' joint may be used in lieu of 'DW' joint at the end of the days work. Remove any pavement damaged due to the drilling at no additional cost to the Contracting Authority. 4 Saw 'C' joint to a depth of T/3. 6 5 Bar supports may be necessary for fixed form paving to ensure the bar remains in a horizontal position in the plastic concrete. The following joints are interchangeable, subject to the pouring sequence: 'BT-1' and 'L-1' 1 2" to 3 4''Top of Pavement Sealant SECTION A-A (Detail at Edge of Pavement) DETAIL C Joint Sealant Material 1 4'' ± 1 16'' Saw Cut 1 1 4'' ± 1 4'' Saw Cut 1 4'' ± 1 8'' Crack or Joint Line A A Pavement Edge See Detail C T Hole Diameter 1 8'' Larger than Dowel 7 18'' Long 3/4" Dowel at 12'' Centers 9'' min.9'' min. 'RD' ABUTTING PAVEMENT JOINT 7 Edge with 1/4 inch tool for length of joint indicated if formed; edging not required when cut with diamond blade saw. Remove header block and board when second slab is placed.T/2 T See Detail A or B T 30'' Long Tie Bar at 12'' Centers 321 'C' CONTRACTION JOINT 'DW' DAY'S WORK JOINT (Non-working) See Detail D-1 or D-2 6 'L-1' CONTRACTION JOINT 1 4'' ± 1 16'' Saw CutJoint Sealant Material 1 4'' ± 1 8'' Saw Cut 4 A A Crack or Joint Line 1 8'' to 5 16'' Saw CutJoint Sealant Material 1 4'' ± 1 8'' 1 1 4'' ± 1 4'' Crack or Joint Line A A DETAIL B (Saw cut formed by approved early concrete sawing equipment.) DETAIL A (Saw cut formed by conventional concrete sawing equipment.) 36'' Long #4 Bars at 30'' Centers T/2 1'' + 1 4'' or - 1 8'' 1"2" DETAIL E Crack or Joint Line T/3 ± 1 4'' Crack or Joint Line T/3 ± 1 4'' Joint Sealant Material 1 8'' ± 1 16'' Saw Cut 1 4'' ± 1 16'' Saw Cut DETAIL D-1 DETAIL D-2 13 (Required when the Department of Transportation is not the Contracting Authority, or when specified in the contract documents) (Required when the Department of Transportation is the Contracting Authority, or when specified in the contract documents.) SIDEWALK DETAIL SCALE NONE 3 C6.1 FINISHED GROUND GRADE (INCLUDING SOD) SHALL BE 1/4" BELOW FINISHED PAVEMENT GRADE ON DOWNHILL SIDE WIDTH PER PLAN NOTE: SLOPE SIDEWALK IN ACCORDANCE WITH GRADING PLAN, 1.5% CROSS SLOPE 6" PCC WALK 12" 12" 6" PCC #4 @ 12" O.C. STRUCTURAL STOOP SEE STRUCTURAL 1/4" EXPANSION JOINT FILLED W/ GRAY MASTIC JOINT SEALANTKEYED JOINT SIDEWWALK SEE PLANS FOR THICKNESS 4" VOID FORMS X WIDTH OF SIDEWALK #4 @ 12" O.C. THUS: 60" ROCK BASE SEE OTHER DETAILS POROUS BACKFILL (IOWA DOT SPEC 4131 OR EQUAL) 6" SUBDRAIN 6" SUBGRADE PREPARATION NYLOPLAST COUPLING (ADS CODE 1579 AG) SCH. 40 PVC TO N-12 (REDUCING COUPLING AS NECESSARY) SCH. 40 PVC ROOF DRAIN LINE (REF MECH) HDPE STORM SEWER (SEE SITE PLAN) ROOF DRAIN CONNECTION DETAIL SCALE NONE 9 C6.1 18 " M I N STORM OR SANITARY SEWER WATER MAIN LOCATED ONE FULL LENGTH OF PIPE SO BOTH JOINTS ARE AS FAR AS POSSIBLE FROM THE WATER MAIN WATER MAIN & STORM OR SANITARY SEWER CROSSING DETAIL SCALE NONE 7 C6.1 NOTES: 1.THIS DETAIL SHALL APPLY ANY TIME A STORM SEWER OR SANITARY SEWER CROSSES OVER OR LESS THAN 18 INCHES BELOW A WATER MAIN. 2.WHEN WATER MAIN CROSSES UNDER STORM OR SANITARY SEWER THE CONTRACTOR SHALL MAINTAIN A MINIMUM OF 18" OF SEPARATION. 3.STORM OR SANITARY SEWER MAY NOT BE PLACED CLOSER THAN 6" BELOW A WATER MAIN. 4.MAINTAIN THE MAXIMUM FEASIBLE SEPARATION IN ALL CASES. 5.SEWER AND WATER PIPES MUST BE ADEQUATELY SUPPORTED & HAVE WATERTIGHT JOINTS. 6.CONTRACTOR SHALL INSTALL LOW PERMEABILITY SOIL FOR BACKFILL MATERIAL WITHIN 10 FEET OF THE CROSSING. 7.IN SANITARY SEWER CROSSINGS, CONTRACTOR SHALL INSTALL ONE FULL LENGTH OF SANITARY SEWER OF WATER MAIN PIPE MATERIAL WITH WATERTIGHT JOINTS LOCATED AS FAR AS POSSIBLE FROM THE CROSSING. 8.IN STORM SEWER CROSSINGS, THE CONTRACTOR SHALL INSTALL ON FULL LENGTH OF STORM SEWER PIPE OF WATER MAIN MATERIAL OR RCP WITH GASKETED JOINTS LOCATED AS FAR AS POSSIBLE FROM THE CROSSING. 9.GASKETED JOINTS SHALL COMPLY WITH ASTM C443. 6" - 1 8 " WATER MAIN PVC & N-12 PIPE BEDDING SCALE NONE 8 C6.1 DETENTION BASIN OUTLET MODIFICATION DETAIL SCALE NONE 10 C6.1 PLAN VIEW ELEV=1000.00 POUR 6" WIDE CONCRETE WEIR WALL, CENTERED IN MANHOLE EXISTING INLET PIPE EXISTING OUTLET PIPE PROFILE VIEW RIM ELEV = 1002.00 ELEV=998.40 24" 4' CEMENT WALL TO BOTTOM OF STRUCTURE TO MAKE WATERTIGHT DRILL OPENING IN CENTER OF WEIR WALL ELEV=992.60 3" OUTLET PIPE (BEHIND WALL) ELEV=992.55 EX 4' 4' SPEED TABLE DETAIL SCALE NONE 11 C6.1 6'6'6' CURB TAPER OUT CURB CURB 6'6'6' PROFILE PLAN TAPER OUT CURB GRADE BREAK 6" T Y P - S E E P L A N 6" T Y P - S E E P L A N TAPER OUT CURB CURB PAVEMENT PAVEMENT 1 2 " 6' PAINTED ARROW HEAD, TYP6' GRADE BREAK CURB GRADE BREAK ADJUST EX STRUCTURE RIM EXISTING MANHOLE HYDRODYNAMIC SEPARATOR DETAIL SCALE NONE 12 C6.1 OWNER MAINTENANCE NOTES: 1.THE OWNER SHALL BE RESPONSIBLE FOR MAINTAINING THE DETENTION BASIN TO ASSURE THE EFFECTIVENESS OF STORM WATER MANAGEMENT. 2.CONDUCT QUARTERLY INSPECTIONS FOR ANY DEFECTS, OBSTRUCTIONS OR CHANGES FROM ORIGINAL DESIGN. 3.REMOVE ALL TRASH, LITTER, DEBRIS OR OBSTRUCTIONS FROM THE BASIN AND ANY INLETS & OUTLETS. 4.INSPECT AND DETERMINE DEPTH OF BASIN ON AN ANNUAL BASIS. 5.REMOVE ANY ACCUMULATED SEDIMENT FROM THE OUTLET STRUCTURE ANNUALLY. REMOVE ANY SEDIMENT ACCUMULATED IN THE BASIN WHEN IT HAS REACHED A DEPTH OF 25% OR MORE OF THE ORIGINAL DESIGN DEPTH. 6.ALL MAINTENANCE, RESTORATION AND REPAIRS SHALL COMPLY WITH THE ORIGINAL DESIGN. OWNER MAINTENANCE NOTES: 1.THE OWNER SHALL BE RESPONSIBLE FOR MAINTAINING THE FIREST DEFENSESTRUCTURE TO ASSURE THE EFFECTIVENESS OF STORM WATER QUALITY TREATMENT. 2.CONDUCT INSPECTIONS EVERY 6 MONTHS TO DETERMINE THE RATE OF SEDIMENT AND FLOATABLE ACCUMULATION. RECORD INFORMATION IN A MAINTENANCE LOG TO ESTABLISH A MAINTENANCE SCHEDULE. 3.CLEAN OUT ALL FLOATABLES AND SEDIMENT AT LEAST ONCE A YEAR. FLOATABLES CAN BE REMOVED WITH A SKIMMER, NET OR VACTOR HOSE. SEDIMENT SHALL BE REMOVED BY A VACTOR HOSE. IF UNIT IS FULL AT EVERY INSPECTION, MORE FREQUENT CLEANING AND SEDIMENT REMOVAL WILL BE NECESSARY. 4.ALL MAINTENANCE, RESTORATION AND REPAIRS SHALL COMPLY WITH THE ORIGINAL DESIGN. 5.REFER TO MANUFACTURER'S RECOMMENDATIONS FOR ADDITIONAL DETAILS. SAN SAN SAN SAN SAN SAN SA N SAN . S T ST ST ST ST D D WILCx BUILDING ADDITION FOOTPRINT = 18,636 MAX HEIGHT = 27'-6" FF=1019.04 H Y D WV S S ST 1 0 1 8 1 0 1 9 1019 1019 1019 1018 1019 1 0 1 9 D CO F F = 1 0 1 9 . 0 4 F F = 1 0 1 9 . 0 4 CO CO CO EP S WV H Y D H Y D WV SD D S ST 15" ST 15" ST 15" ST 15" ST 15" ST 15" ST 15" S T S T S T S T S T ST 15 " ST 15 " ST 15"ST 15"ST 15" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W8"W8"W8"W8"W8"W8"W8"W8"W8"W8"W8"W8" W6" EXTISTING BUILDING FOOTPRINT = 35,770 SF FF = 1019.04 1022 1021 10 1 8 101 9 1019 1018 1020 1019 1 0 1 7 1 0 1 6 1 0 1 5 1 0 1 8 101 7 1016 1017 1 0 1 7 101 6 1015 1014 10 1 3 1 0 1 8 1 0 1 6 1 0 1 5 1 0 1 4 101 8 1018 1018 1019 101 9 SAN 6" SA N 8 " F/O F/O F/O F/ O F/ O F/ O F/ O F/ O F/ O F/ O ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6"ST 6" ST 6" SA N 6" SAN 6" SA N 10 " S FUTURE TRAIL EA S E M E N T SA N S W R E A S E M E N T B K 2 0 1 4 P G 6 0 8 8 10 ' P . U . E . B K 2 0 1 3 P G 2 1 2 9 6 10' P.U.E. BK 2013 P G 2 1 2 9 6 10' P.U.E. BK 2013 P G 2 1 2 9 6 SA N S W R E A S E M E N T B K 2 0 1 4 P G 6 0 8 8 SE L A G R A N T P K W Y SE ASHWORTH R D 10' ELEC EASEMENT BK 2015 PG17280 W 12 " W12 " W12 " W12 " W12 " W12 " W12 " W12 " W12 " W12 " W12 " W12 " W12 " ST 15 " ST 15 " ST 15 " ST 15 " 1018 101 710 1 8 10 1 9 D ST 15" H Y D FILTER SOCK SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF INLET PROTECTION (TYP) FILTER SOCK SF SF SF SF SF SF SF SF SF SF SFSFSILT FENCE SF SF PLANNING ARCHITECTUREINTERIORS OWNER SIGN-OFF: REVISIONS: DATE NAME CONSULTANT: 303 Watson Powell Jr. Way Suite 200 Des Moines, Iowa 50309 515.633.2941 515.633.2942 Fax www.invisionarch.com Copyright C 2022 SHEET NAME: PROJECT NO: DATE: SHEET SET: SHEET: PRELIMINARY NOT FOR CONSTRUCTION BISHOP ENGINEERING COMPANY, INC IMEG CORP IMEG CORP CIVIL STRUCTURAL MEP 08.23.2022 21209 WI L C x 29 5 S E A S H W O R T H R O A D W A U K E E , I A 5 0 2 6 3 WA U K E E C O M M U N I T Y S C H O O L D I S T R I C T 3RD CITY SUBMITTAL Description Date No. L: \ L A N D P R O J E C T S 2 0 2 2 \ 2 2 0 0 6 1 W A U K E E W I L C E X P A N S I O N \ D W G \ C 7 S W P P P . D W G 8/ 2 3 / 2 0 2 2 1 1 : 4 6 : 0 3 AM Bi s h o p E n g i n e e r i n g IOWAONE CALL 1-800-292-8989 www.iowaonecall.com 811 Know what's below. Call before you dig. UTILITY NOTE: THE LOCATION OF THE UTILITIES INDICATED ON THE PLANS ARE TAKEN FROM EXISTING PUBLIC RECORDS AND ARE APPROXIMATE LOCATIONS. THE EXACT LOCATIONS OF ALL UTILITIES MUST BE ASCERTAINED IN THE FIELD. IT SHALL BE THE DUTY OF THE CONTRACTOR TO DETERMINE WHETHER ANY ADDITIONAL FACILITIES OTHER THAN THOSE SHOWN ON THE PLANS MAY BE PRESENT. EROSION CONTROL NOTES: 1.EROSION CONTROL PLAN IS CONSIDERED A LIVING DOCUMENT AND WILL NEED PERIODIC UPDATES AND ADJUSTMENTS AS NECESSARY DEPENDING ON SITE CONDITIONS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO UPDATE THE EROSION CONTROL PLAN AND IMPLEMENT ANY AND ALL MEASURES NECESSARY. 2.INSTALL PERIMETER SILT FENCE AS SHOWN ON PLANS PRIOR TO CONSTRUCTION. 3.INSTALL INTAKE PROTECTION WITH SILT FENCE IMMEDIATELY AFTER STORM SEWER CONSTRUCTION. 4.INSTALL FINISHED PAVING INLET PROTECTION IMMEDIATELY AFTER PAVING IS COMPLETED AROUND INTAKE. 5.OTHER EROSION CONTROL TYPES MAY NOT BE SUBSTITUTED FOR SILT FENCE. 6.CONTRACTOR SHALL BE RESPONSIBLE FOR SUPPLYING A CONCRETE WASHOUT IN ACCORDANCE WITH SUDAS SPECIFICATION11,050 DURING ALL CONCRETE WORK. 7.CONTRACTOR SHALL BE RESPONSIBLE FOR SUPPLYING TEMPORARY RESTROOM FACILITIES. SANITARY WASTE SHALL BE DISPOSED OF PER ALL FEDERAL, STATE AND LOCAL REGULATIONS. 8.CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING ALL TOPSOIL REQUIREMENTS ARE MET. NOT TO SCALE SITE ENTRANCE DETAIL TEMP. ROCK ENTRANCE (PLAN VIEW) (PROFILE VIEW) TEMP. ROCK ENTRANCE 3" CLEAN LIMESTONE PLACE ROCK ON FABRIC STABILIZED ENTRANCE SHALL BE AT LEAST 50' LONG AND EXTEND TO THE PUBLIC ROADWAY. 5' - 0 " M I N . GROUND LINE ENGINEERING FABRIC FLOW 2 1' ABOVE GROUND LINE VARIABLE 10' MAX.5' MAX.5' MAX.10' MAX. 1' ABOVE GROUND LINE SECURE TOP OF ENGINEERING FABRIC ENGINEERING FABRIC TO BE PLACED TO BOTTOM OF TRENCH. 1 2 ENGINEERING FABRIC GROUND LINE TRENCH BOTTOM TRENCH BOTTOM 1 1 1 LINEGROUND 1 MIN. 4" EXCESS FABRIC COMPACTED BACKFILL 12 " MI N . DETAIL OF SILT FENCE AT DITCH OR SWALE DETAIL OF SILT FENCE 8' SPACING TO TOP OF STEEL POST. SEE DETAIL OF ATTACHMENT TO POST. VERTICAL CUT WIRE CORD CORD CORD WIRE POST FABRIC FABRIC BACK VIEW OF FABRIC BACK VIEW ATTACHMENT TO POST 3 4 NOTES : 3 MAKE VERTICAL CUT IN TOP OF FABRIC. PULL OUT AND TWIST CORD. 4 LOOP CORD AROUND POST FORMING A LOOP. PULL WIRE THROUGH FOLD AREA OF FABRIC AND SECURE AROUND POST. 'T' STEEL FENCE POST NORMAL FORESLOPE 2" RISE IN FENCE 31" MIN. NORMAL BACKSLOPE 31 " M I N . 6" TRENCH DEPTH FOR NORMAL INSTALLATION (MIN.) 12" TRENCH DEPTH FOR DITCH INSTALLATION NOT TO SCALE (SECTION VIEW) (PROFILE VIEW) SILT FENCE DETAILS NOT TO SCALE INLET 5'-0" 5'-0" 'T' FENCE POST, 5' MIN. NOTES: 1. SECURE TOP OF FABRIC TO POSTS, USING CABLE TIES OR WIRE. 2. FABRIC TO BE BURIED 12", AND FOLDED ALONG BOTTOM. 3. STEEL POSTS TO BE EMBEDDED 28". (PLAN VIEW) DROP INLET BASKET PROTECTION SILT FENCE FABRIC IF APPLICABLE INLET PROTECTION DETAIL NOT TO SCALE NOTES: 1. 1 C.Y. CONCRETE BAG SHALL BE REQUIRED AT ANY LOCATION WHERE CONCRETE IS USED. 2. CONCRETE WASHOUT DUMPSTER W/ HEAVY DUTY LINER IS AN ACCEPTIBLE ALTERNATIVE (PLAN VIEW) 1 C.Y. CONCRETE WASH-OUT BAG 'T' FENCE POST 5' MIN CONCRETE WASH-OUT BAG DETAIL (PROFILE VIEW) 1 C.Y. CONCRETE WASH-OUT BAG GRAPHIC SCALE 020 10 20 40 EROSION CONTROL PLAN C7.1 EROSION CONTROL REMOVAL NOTES: 1.AFTER FINAL STABILIZATION HAS OCCURED, CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL TEMPORARY EROSION CONTROL DEVICES INCLUDING, BUT NOT LIMITED TO: SILT FENCE, INLET PROTECTION, AND TEMPORARY STANDPIPES.