Loading...
HomeMy WebLinkAbout2022-10-17 I14 Guadalajara Restaurant_Site PlanAGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: October 17, 2022 AGENDA ITEM:Consideration of approval of a resolution approving a site plan for Guadalajara FORMAT:Resolution SYNOPSIS INCLUDING PRO & CON: Waukee Crossing, LLC requests approval of a site plan to authorize the construction of Guadalajara, a site-down restaurant, located at the intersection of Hickman Road and NW 2nd Street. The building will be approximately 7,307-square-feet and one story. A covered patio is shown in the southeast corner and a trash enclosure is shown in the northwest corner. Two access points to the site will be provided off of NW 2nd Street. The north entrance will be full-access and the south entrance will be a right-in / right-out only. Ten-foot trails exist along the south side and east side of the property. The applicant has provided elevations for the proposed building on the site. The design and materials are consistent with the Site Plan Ordinance. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning Commission reviewed this project at the October 11, 2022, Commission Meeting and recommended approval subject to remaining staff comments: Consider a request from Waukee Crossing, LLC for approval of a Site Plan for Guadalajara Restaurant (185 West Hickman Road) City Planner, Bill Mettee, provided an outline of the project, as shown in the staff report. The applicant, Waukee Crossing, LLC is requesting approval of a Site Plan for a restaurant located at the intersection of Hickman Road and NW 2nd Street. The parcel contains 1.61-acres and is zoned C-1 Community and Highway Service Commercial. Mr. Mettee explained the project would include the construction of a single-story restaurant, approximately 7,307-square feet in area with a covered patio in the southeast corner. Two accesses are proposed off of NW 2nd Street – the northerly entrance will be full-access and the southerly entrance will be a permanent right-in / right-out entrance. The applicant is providing the required 110 parking spaces. Ten-foot trails exist along Hickman Road and NW 2nd Street. A pedestrian entrance will be provided off the trail on Hickman Road. Elevations were provided for review which include materials such as Stone, Glass and Vertical Metal Siding. I14 The applicant is providing 20% open space, where 20% is required. Storm water detention will be provided in the existing regional detention basin that was approved during Waukee Crossing Plat 4. Parking, landscaping, open space and lighting requirements all meet the site plan ordinance and staff recommended approval of the Site Plan for Guadalajara subject to remaining staff comments. Commissioner Streit asked about the entrances, verifying that one was right-in / right-out. Mr. Mettee confirmed the entrances. Motion was made by Kullen Koelker to approve the Site Plan. The motion was seconded by Angie Tessau. On voice vote: All ayes: Motion carries 6-0 STAFF REVIEW AND COMMENT: Staff recommends approval of the site plan subject to remaining staff comments. RECOMMENDATION: Approve the resolution subject to remaining staff comments. ATTACHMENTS: I. Proposed Resolution II. Staff Report III. Site Plan & Elevations PREPARED BY:Bill Mettee, Planner REVIEWED BY: THE CITY OF WAUKEE, IOWA RESOLUTION 2022- APPROVING THE SITE PLAN FOR GUADALAJARA IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Site Plan for Guadalajara, subject to remaining staff comments on October 11, 2022; AND, WHEREAS, the Site Plan for Guadalajara is in general conformance with §160 – Site and Building Development Standards Ordinance of the Waukee Municipal Code; AND, WHEREAS, the Site Plan for Guadalajara is in general conformance with §161 – Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND, NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 17th day of October, 2022 that the Site Plan for Guadalajara is approved subject to remaining staff comments. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Anna Bergman Pierce R. Charles Bottenberg Chris Crone Larry R. Lyon Ben Sinclair PLANNING AND ZONING COMMISSION STAFF REPORT PROJECT: Guadalajara – Site Plan PREPARED BY: Bill Mettee – Planner REPORT DATE: October 7, 2022 MEETING DATE: October 11, 2022 GENERAL INFORMATION Owner: Waukee Crossing, LLC Applicant: Guadalajara Restaurant Project Manager: Brandon Short, Pelds Engineering Request:The applicant is requesting approval of a site plan for a restaurant. Location and Size:Property is located north of Hickman Road and west of NW 2nd Street, containing approximately 1.61 acres. Property Address: 185 W. Hickman Road AREA MAP ABOVE: Aerial of subject property (outlined in RED) in relation to the surrounding area. October 6, 2022 2 of 3 LAND USES AND ZONING Location Existing Land Use Comprehensive Plan Current Zoning Property in Question Vacant - Undeveloped Mixed Use C-1 (Community and Highway Service Commercial District) North Vacant - Undeveloped Mixed Use C-1 (Community and Highway Service Commercial District) South Vacant - Undeveloped Mixed Use C-1 (Community and Highway Service Commercial District) East Hy-Vee Fast & Fresh Mixed Use C-1 (Community and Highway Service Commercial District) West Vacant – Undeveloped Mixed Use C-1 (Community and Highway Service Commercial District) PROJECT DESCRIPTION The project involves the construction of a single-story restaurant. The building is proposed to be approximately 7,307 square feet in area. A covered patio will be provided on the southeast corner of the building. The trash enclosure is shown to be to the northwest of the building. While there is a monument sign easement in the southeast corner of the property, no monument signs are proposed at this time. ACCESS AND PARKING Two accesses are provided to this site from NW 2nd Street. The south entrance will be a permanent right-in / right-out access A total of 110 parking spaces are proposed and 110 parking spaces are being provided. The proposed site plan meets the parking requirements of the ordinance. SIDEWALKS/TRAILS Two trails exist along Hickman Road and NW 2nd Street. A pedestrian sidewalk will be provided into the site from the trail along Hickman Road. UTILITIES All utilities will be provided to this site. Storm water detention will be accommodated in the existing regional detention basin that was approved during Waukee Crossing Plat 4. LANDSCAPING & OPEN SPACE A minimum of 20% of the project area is required to be open space. The total amount of open space proposed is 20%.The applicant has provided the required number of plantings per the landscaping ordinance. ELEVATIONS The elevations of the building are proposed to be constructed primarily of Stone, Glass and Vertical Metal Siding. The elevations comply with the Site Plan Ordinance. October 6, 2022 3 of 3 MISCELLANEOUS: The applicant has submitted a photometric plan and associated light fixture cut sheets. The lighting plan meets the lighting requirements of the Site and Building Development Standards. STAFF RECOMMENDATION Staff recommends approval of the site plan for Guadalajara subject to remaining staff comments. PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 VICINITY MAP SITE PLAN FOR GUADALAJARA RESTAURANT 185 W HICKMAN RD WAUKEE, IOWA C-001 - COVER SHEET C-002 - NOTE SHEET C-101 - TOPO SHEET C-102 - SITE SHEET C-103 - UTILITY SHEET C-104 - GRADING SHEET C-105 - GRADING DETAIL SHEET C-106 - EROSION & SEDIMENT CONTROL SHEET C-107 - LANDSCAPING SHEET SHEET INDEX LOT 1 IN WAUKEE CROSSING PLAT 4, AN OFFICIAL PLAT, NOW INCLUDED IN AND FORMING A PART OF WAUKEE, DALLAS COUNTY, IA, CONTAINING 1.61 ACRES, MORE OR LESS. C-001 - C-107 SITE ADDRESS 185 W HICKMAN RD WAUKEE, IOWA 50263 SITE USE RESTAURANT ZONING EXISTING:C-1 PROPOSED: NO CHANGE ADJACENT ZONING: C-1 SETBACKS FRONT:30 SIDE:30 REAR:N/A BUILDINGS PROPOSED:~ 74 x 98 - 7,307 SQ.FT. PATIO:~46X20 - 876 SQ.FT. BUILDING HEIGHT MAX BUILDING HEIGHT:N/A PROPOSED HEIGHT:26 FT PAVING ENTRANCE:8" THICK NON REINFORCED P.C.C. WITH MINIMUM 6" CRUSHED ROCK SUBBASE*** PARKING LOT:6" THICK NON REINFORCED P.C.C. WITH MINIMUM 6" CRUSHED ROCK SUBBASE** CURB:6" TALL STANDARD CURB SIDEWALK 4" THICK P.C.C ***6" CRUSHED ROCK SUBBASE THAT COMPLIES WITH AASHTO M147 GRADE C OR GRADE D AND SUBGRADE THAT IS COMPACTED TO 95% STANDARD PROCTOR DENSITY. GEOTECHNICAL REPORT UNAVAILABLE AT THE TIME OF CIVIL SET PREPARATION. VERIFY SUBBASE DEPTH WITH ENGINEER PRIOR TO CONSTRUCTION. MAXIMUM JOINT SPACING = PAVEMENT THICKNESS*1.5 = 6*1.5 = 9 FT OR 1.5*8 = 12 FT SITE AREA 1.61 ACRES (70,185 SQ.FT.) OPEN SPACE EXISTING:100% (70,185 SQ.FT.) PROPOSED:20% (55,285 SQ.FT.) REQUIRED:20% (14,037 SQ. FT.) IMPERVIOUS SPACE EXISTING:0% (0 SQ.FT.) PROPOSED:80% (55,900 SQ.FT.) PARKING REQUIRED:110 SPACES (15/1000 SQ.FT. BLDG. = 7307 *15 / 1000) PROVIDED:110 SPACES (INCLUDING 5 HANDICAP PARKING STALLS) SIGN BUILDING SIGN ONLY - SIGNS TO BE REVIEWED AND APPROVED UNDER A SEPARATE PROCESS. DISTURBED AREAS ESTIMATED:87,400 SQ.FT. ALL DISTURBED AREAS SHALL BE SODDED. THE DISTURBED AREA FOR THIS SITE IS GREATER THAN 1 ACRE, THEREFORE A NPDES PERMIT IS REQUIRED. FLOODPLAIN PER FEMA MAP #19049C0335F, THE SITE IS LOCATED IN ZONE X, AREA OF MINIMAL FLOOD HAZARD FAA PER FAA NOTICE CRITERIA TOOL, SITE DOES NOT EXCEED NOTICE CRITERIA UP TO 26 FT HEIGHT (FOR BUILDING HEIGHT) AND THEREFORE FILING WITH THE FAA IS NOT REQUIRED REQUIRED PERMITS SIGN PERMIT DOT PERMIT FOR WORK WITHIN HICKMAN ROW GENERAL PERMIT #2 COSESCO PERMIT SITE LIGHTING MUST BE APPROVED BY CITY PRIOR TO INSTALLATION. SUBMITTAL DATES 1ST:8/16/2022 2ND:9/6/2022 3RD:9/20/2022 OWNER WAUKEE CROSSING, LLC 611 MONTICELLO DR BURLINGTON, IA 52601 PROJECT CONTACT: ---- PHONE: ---- EMAIL: ---- CITY CONTACT WAUKEE COMMUNITY DEVELOPMENT 230 W HICKMAN RD WAUKEE, IA 50263 PROJECT CONTACT: ANDY KASS PHONE: 515-978-7897 EMAIL: AKASS@WAUKEE.ORG PROSPECTIVE BUYER AJ COMMERCIAL, LLC 2540 73RD ST URBANDALE, IA 50322 PROJECT CONTACT: JAMES M. MYERS, PARTNER PHONE:515-440-1111 EMAIL:JAMIE@PREMIER-MIDWEST.COM ENGINEER/ LAND SURVEYOR PELDS DESIGN SERVICES 2323 DIXON ST DES MOINES, IOWA 50316 PROJECT CONTACT: ELARA JONDLE PHONE: (515) 265-8196 EMAIL: ELARA@PELDS.COM ARCHITECT PELDS DESIGN SERVICES 2323 DIXON ST DES MOINES, IA 50316 PROJECT CONTACT: DANIEL WILLRICH PHONE: 515-265-8196 EMAIL: DANIEL@PELDS.COM SITE LOCATION LEGAL DESCRIPTION: REVISIONS: (CTLIA01 ) CENTURYLINK CONTACT NAME : SADIE HULL CONTACT PHONE: 9185470147 CONTACT EMAIL: SADIE.HULL@LUMEN.COM (DALLIA1 ) MEDIACOM CONTACT NAME : KEVIN COLLINS CONTACT PHONE: 5152466668 CONTACT EMAIL: KCOLLINS1@MEDIACOMCC.COM (ENV ) CONSOLIDATED COMMUNICATIONS CONTACT NAME : JUSTIN GREV CONTACT PHONE: 5073863606 CONTACT EMAIL: JUSTIN.GREV@CONSOLIDATED.COM (INS ) AUREON NETWORK SERVICES CONTACT NAME : JEFF KLOCKO CONTACT PHONE: 5158300445 CONTACT EMAIL: JEFF.KLOCKO@AUREON.COM (M57E ) MIDAMER-ELEC CONTACT NAME : JAMIE NEER CONTACT PHONE: 5152526972 CONTACT EMAIL: MECDSMDESIGNLOCATES@MIDAMERICAN.COM LEGEND: MORE OR LESS GUTTER ELEVATION TOP OF CURB ELEVATION +/- EXISTING/ PROPOSED ELEVATION 123.45G 123.45TC FLOWLINE ELEVATIONFL FINISHED FLOORF.F. 123.45123.45/ CALCULATED CORNER FOUND CORNER CONTROL POINT ELEC. TRANSFORMER ELEC. METER ELEC. BOX SIGN PARKING SPACE STREET LIGHT POWER POLE LIGHT POLE CALCULATED SECTION CORNER FOUND SECTION CORNER AREA LIGHT GUY ANCHOR ELEC. MANHOLE ELEC. VAULT GAS VALVE GAS METER UTILITY PEDESTAL CABLE TV JUNCTION BOX SANITARY SEWER MANHOLE STORM SEWER MANHOLE CLEANOUT DOWNSPOUTD SINGLE INTAKE WATER VALVE WATER TEE FLARED END SECTION FIRE HYDRANT VALVE PROPOSED UTILITY LINEP XX EXISTING UTILITY LINEE XX WATER METER THROAT INTAKE FENCE LINE FIBER OPTIC WATER GAS LINE SANITARY SEWER STORM SEWER UNDERGROUND TEL. OVERHEAD TEL. W ST UGT OHT G SAN UNDERGROUND ELEC.UGE OVERHEAD ELEC.OHE FO CABLE TELEVISIONCATV AREA INTAKE BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: C-001 - COVER SHEET 10-04-22 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: B. SHORT J:\2022 Projects\22-001 - Guadalajara Restaurant - Waukee\Engineering\Site Plan\Sheet Set WAUKEE, IOWA GUADALAJARA RESTAURANT 185 W HICKMAN RD TITLE: ----22-001 PRELIMINARY I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF IOWA. _______________________________________________________ VOLDEMARS L. PELDS, P.E. IA. LIC. NO. 18842 DATE MY LICENSE RENEWAL DATE IS DECEMBER 31, 2023 ADDITIONAL PAGES OR SHEETS COVERED BY THIS SEAL (NONE UNLESS INDICATED HERE):_________________________________ ________________________________________________________ VOLDEMARS L. 18842 PELDS IOWA L I C E N S ED PROFE S S I O N A L SURVEYOR ENGINEER & D N A L (MC1 ) VERIZON CONTACT NAME : JOHN BACHELDER CONTACT PHONE: 9727297000 CONTACT EMAIL: ASG.INVESTIGATIONSTEAM@ASGINC.US (MIFI ) MI-FIBER CONTACT NAME : JACK JONES CONTACT PHONE: 5158979192 CONTACT EMAIL: JACK@GRM.NET (UPN ) UNITE PRIVATE NETWORKS, LLC CONTACT NAME : JOE KILZER CONTACT PHONE: 8164253556 CONTACT EMAIL: UPNGIS@UPNFIBER.COM (WKE ) WAUKEE, CITY OF CONTACT NAME : TIM ROYER CONTACT PHONE: 5159787920 CONTACT EMAIL: TROYER@WAUKEE.ORG (XR1 ) XENIA RURAL WATER DISTRICT CONTACT NAME : LAIRD VAN DEE CONTACT PHONE: 5156762117 CONTACT EMAIL: LVANDEE@XENIAWATER.ORG US 6/HICKMAN RD NW 2 N D S T NW VENTURE DR PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 FOR GUADALAJARA RESTAURANT 185 W HICKMAN RD WAUKEE, IOWA PAVING NOTES 1.THE PAVING/ GRADING CONTRACTOR SHALL BACKFILL THE PAVING SLAB AND FINE GRADE THE RIGHT OF WAY AS SOON AFTER THE PAVING AS POSSIBLE. ALL AREAS SHALL BE SODDED IN ACCORDANCE WITH CITY OF WAUKEE SPECIFICATIONS AND THE LATEST VERSION OF SUDAS. 2.SEE DETAILS FOR ALL PAVEMENT THICKNESS. 3.DETECTABLE WARNING PANEL(S) CALLED OUT ON PLANS SHALL BE PER A.D.A. REGULATIONS. PANEL TYPE & COLOR SHALL BE PER CITY STANDARD. 4.SIDEWALKS SHALL HAVE EXPANSION JOINTS AT 100 FOOT INTERVALS AS REQUIRED BY CITY CODE 5.ALL WALKS, PARKING LOTS, HANDICAP PARKING, RAMPS, ETC. SHALL COMPLY WITH ALL A.D.A. AND CITY CODES. HANDICAP PARKING SIGNAGE IS REQUIRED FOR ALL HANDICAP STALLS AND SHALL BE CONSIDERED INCIDENTAL. IN EVENT OF A DISCREPANCY BETWEEN THE PLANS AND THE A.D.A./CITY CODES THE A.D.A./CITY CODES SHALL GOVERN. CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING A.D.A. CODES ARE MET. PAVEMENT SAWCUT NOTES 1.CONTRACTOR TO PROVIDE SAWCUT JOINTING PLAN PRIOR TO ANY CONCRETE PAVEMENT INSTALLATION. 2.PAVEMENT MAY BE REQUIRED TO BE REMOVED AND REPLACED IF PLACED WITHOUT AN APPROVED PLAN. 3.LONGITUDINAL JOINTS IN DRIVE LANES & THE OUTER MOST JOINT OF ALL PARKING AREAS SHALL BE SUDAS TYPE 'L-1' OR 'L-2' JOINTS AND HAVE STEEL. INTERIOR PARKING LOT JOINTS, OTHER THAN THE OUTER MOST JOINT, DO NOT NEED STEEL AND SHALL BE SUDAS TYPE 'B' OR TYPE 'K' JOINTS. ALL TRANSVERSE JOINTS SHALL BE SUDAS TYPE 'C' OR TYPE 'DW' JOINTS WITH STEEL IN THE CASE OF A DAY'S WORK JOINT. SOIL NOTES 1.STRIP AND STOCKPILE THE TOP 8 INCHES OF SOIL ON ALL DISTURBED AREAS. GRADING CONTRACTOR SHALL RESPREAD TOPSOIL TO A MINIMUM DEPTH OF 8 INCHES.. 2.SOD REQUIREMENT PER SUDAS: IN AREAS WHERE TOPSOIL HAS BEEN STRIPPED, A SODBED SHOULD BE CONSTRUCTED BY SPREADING A MINIMUM OF 8 INCHES OF TOPSOIL PRIOR TO SODDING. DEEPER TOPSOIL DEPTHS (UP TO 12 INCHES OR GREATER) ARE DESIRABLE AS THEY INCREASE THE ORGANIC MATTER AVAILABLE FOR USE BY THE PLANTS, ALLOW FOR DEEPER ROOT PENETRATION AND INCREASE THE MOISTURE HOLDING ABILITY OF THE SOIL. 3.TOPSOIL SHALL BE FREE OF ALL ROCK AND DEBRIS LARGER THAN 3/4" IN SIZE. 4.TOPSOIL IS DEFINED AS: FERTILE, FRIABLE LOAM, CAPABLE OF SUSTAINING VIGOROUS PLANT GROWTH, FROM WELL DRAINED SITE FREE FROM FLOODING, NOT IN FROZEN OR MUDDY CONDITIONS; REASONABLE FREE FROM SUBSOIL, CLAY LUMPS, ROOTS, GRASS, WEEDS, STONES LARGER THAN 3/4 INCH IN DIAMETER, AND FOREIGN MATTER; ACIDITY RANGE (PH) OF 5.5 TO 7.5; CONTAINING MINIMUM 4 PERCENT AND MAXIMUM 20 PERCENT ORGANIC MATTER. 5.CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING ALL TOPSOIL REQUIREMENTS OF NPDES GENERAL PERMIT NO. 2 ARE MET. 6.REFERENCE GEOTECHNICAL REPORT FOR ADDITIONAL SOILS INFORMATION INCLUDING BUT NOT LIMITED TO SUBGRADE INFORMATION, FOOTING DESIGN, AND ANY POSSIBLE OVER EXCAVATION DUE TO POOR SOILS. PAVEMENT SECTIONS ON THE PLANS GOVERN OVER PAVEMENT THICKNESS IN THE SOILS REPORT. GRADING NOTES 1.AREAS TO RECEIVE STRUCTURAL FILL SHALL BE BENCHED. STRUCTURAL FILL SHALL BE COMPACTED TO A DENSITY THAT IS NOT LESS THAN 95% STANDARD PROCTOR. 2.PREPARE BOTTOM OF BENCH FOR FILL BY DISKING TO A DEPTH OF 12 INCHES AND COMPACT. ANY LOCALIZED AREAS WHICH CANNOT BE SATISFACTORILY COMPACTED OR WHICH SHOW EVIDENCE OF PUMPING ACTION SHALL BE UNDERCUT AND RE-COMPACTED WITH ON-SITE FILL MATERIALS. 3.ALL AREAS WHICH ARE TO RECEIVE PAVING SHALL HAVE THE TOP 12 INCHES DISKED AND COMPACTED TO 95% STANDARD PROCTOR DENSITY. 4.MAINTAIN ALL CUT AND FILL AREAS TO ACCOMMODATE SURFACE DRAINAGE. 5.FINISH GRADE ON ALL NON-PAVED AREAS SHALL BE WITHIN 0.20 FT, AND PAVED AREAS SHALL BE WITHIN 0.10 FT OF THE PROPOSED GRADES SHOWN ON THE PLAN 6.MAXIMUM ALLOWABLE GRADE ON ALL PROPOSED SLOPES IS 3:1. 7.THE MOISTURE CONTENT SHALL NOT DEVIATE FROM THE OPTIMUM BY MORE THAN 2% IN STRUCTURAL FILL. 8.MAXIMUM 2% CROSS-SLOPE ON ALL SIDEWALKS. 9.GRADING AND EROSION CONTROL SHALL BE DONE IN ACCORDANCE WITH THE APPROVED GRADING PLAN, SWPPP, NPDES DOCUMENTS, AND IOWA DEPARTMENT OF NATURAL RESOURCES REQUIREMENTS. LANDSCAPING NOTES 1.ALL SODDING & LANDSCAPE PLANTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE URBAN STANDARD SPECIFICATIONS, UNLESS SPECIFIED OTHERWISE. 2.SOD ALL DISTURBED AREAS WITHIN THE CONTRACT LIMITS, UNLESS NOTED OTHERWISE. SOD LIMITS SHOWN ON PLAN ARE FOR REFERENCE ONLY. FINAL LIMITS MAY CHANGE BASED ON CONSTRUCTION ACTIVITIES. SOD ALL DISTURBED AREAS OFF-SITE 3.STAKE SOD ON ALL SLOPES 4:1 OR GREATER. 4.PLANT QUANTITIES ARE FOR CONTRACTORS CONVENIENCE, THE DRAWING SHALL PREVAIL IF A CONFLICT OCCURS. 5.ALL PLANT MATERIAL SHALL CONFORM TO THE LATEST EDITION OF THE AMERICAN STANDARD FOR NURSERY STOCK (ANSI Z60.1). 6.CONTRACTOR SHALL GUARANTEE ALL PLANT MATERIAL FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE. 7.CONTRACTOR SHALL PLACE SHREDDED HARDWOOD MULCH OR BRICK CHIPS OR WASHED STONE AROUND ALL TREES, SHRUBS AND GROUND COVER BEDS TO A DEPTH OF 4 INCHES, UNLESS NOTED. 8.PROVIDE 6MIL MINIMUM PLASTIC BELOW ROCK/BRICK. 9.THE LANDSCAPING CONTRACTOR SHALL HAVE ALL UTILITIES LOCATED BEFORE STARTING ANY SITE WORK OR PLANTING. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING UTILITIES. 10.CONTRACTOR SHALL BE RESPONSIBLE MAINTAINING APPROPRIATE LEVEL OF WATERING FOR ALL NEW PLANTS FOR A PERIOD OF 30 DAYS. 11.CONTRACTOR SHALL DESIGN AND PROVIDE IRRIGATION SYSTEM. COORDINATION WITH ARCHITECT REQUIRED. 12.ALL BEDS TO RECEIVE GRANULAR PRE-EMERGENT WEED CONTROL BEFORE AND AFTER MULCH IS INSTALLED. UTILITY NOTES 1.QUANTITY CALLOUTS ON PIPE LENGTHS ARE APPROXIMATE AND SHOULD BE USED FOR REFERENCE ONLY. 2.PIPE LENGTHS CALLED OUT ON PLANS DO NOT INCLUDE FLARED END SECTION, WHERE APPLICABLE. 3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION OF ALL UTILITIES. ANY DAMAGE TO SAID UTILITIES SHALL BE REPAIRED TO THE SATISFACTION OF THE OWNER AT THE CONTRACTORS EXPENSE. 4.THE CONTRACTOR SHALL RELOCATE EXISTING UTILITIES AS NECESSARY, SHOWN OR NOT SHOWN. 5.THE CONTRACTOR SHALL COORDINATE WITH THE CITY ON ALL SIZE, DEPTHS, AND MATERIALS OF ALL PROPOSED UTILITIES. 6.THE CONTRACTOR MUST PROVIDE AS-BUILTS OF ALL UTILITIES, INCLUDING DEPTH AND LOCATION OF ALL SERVICES IF REQUIRED BY CITY. 7.IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE APPROPRIATE UTILITY COMPANIES PRIOR TO CONNECTION OR DISCONNECTION OF A SERVICE LINE. 8.CONTRACTOR IS TO COMPLY WITH 2022 SUDAS SPECIFICATIONS AND 2020 WAUKEE STANDARD SPECIFICATIONS FOR MAINTENANCE, INSTALLATION, AND TESTING FOR CONSTRUCTION. 9.THE CONTRACTOR SHALL COORDINATE THE ADJUSTMENT OF ANY AND ALL EXISTING AND PROPOSED UTILITIES TO PROPOSED GRADES. EXISTING UTILITIES SHALL BE RAISED OR LOWERED IN ACCORDANCE WITH THE UTILITY OWNER REQUIREMENTS. ANY NECESSARY ADJUSTMENTS SHALL BE CONSIDERED INCIDENTAL TO CONSTRUCTION. 10.ACTIVE EXISTING FIELD TILES ENCOUNTERED DURING CONSTRUCTION SHALL BE REPAIRED, REROUTED, OR CONNECTED TO PUBLIC OR PRIVATE STORM SEWER TO REMAIN IN SERVICE. THE TILE SHOULD BE DIRECTED TO PUBLIC STORM SEWER IF POSSIBLE. THE CONTRACTOR SHALL RECORD THE ELEVATION AND LOCATION OF ALL TILES. 11.ALL RIP RAP CALLED OUT ON PLANS SHALL BE UNDERLAIN WITH ENGINEERING FABRIC. 12.ALL STRUCTURE SIZES CALLED OUT ON PLANS ARE MINIMUM INSIDE WALL DIMENSIONS. 13.ALL PROPOSED UTILITIES SHALL BE PRIVATE, UNLESS NOTED OTHERWISE. 14.ALL STRUCTURES CALLED OUT AS "MODIFIED" OR "SPECIAL" SHALL BE ENGINEERED BY THE PRECASTER TO ENSURE STRUCTURE STABILITY. MODIFICATIONS INCLUDE ADDITIONAL WALL LENGTH TO ACCOUNT FOR LARGE PIPE DIAMETERS AND ADDITIONAL WALL WIDTH & BASE DEPTH TO ACCOUNT FOR DEEPER STRUCTURES. ANY AND ALL MODIFICATIONS TO STANDARD STRUCTURES SHALL BE CONSIDERED INCIDENTAL TO BID ELECTRICAL SERVICE NOTES 15.ALL SITE LIGHTING SHALL NOT SPILL ONTO ADJACENT PROPERTIES OR RIGHT-OF-WAYS 16.TRANSFORMER PAD IS SHOWN FOR REFERENCE ONLY AND MAY NOT BE DRAWN TO ACTUAL SIZE. PAD SHALL CONFORM TO ALL UTILITY COMPANY DESIGN STANDARDS AND SPECIFICATIONS. SANITARY SERVICE NOTES 17.SANITARY SEWER SERVICE CONNECTIONS SHALL BE PLACED AT A SLOPE OF NO LESS THAN 2% FOR A 4" PIPE AND 1% FOR A 6" PIPE. SERVICES SHALL MAINTAIN 18" OF VERTICAL SEPARATION FROM THE WATER MAIN WITH 18" OF COMPACTED LOW PERMEABILITY SOIL BETWEEN THE UTILITIES WITHIN 10' OF THE CROSSING. STORM WATER SERVICE NOTES 18.ALL STORM SEWER IN THE ROW SHALL BE RCP (CLASS III RCP), UNLESS OTHERWISE SPECIFIED. 19.ALL PROPOSED RCP STORM SEWER PIPE JOINTS SHALL BE FABRIC WRAPPED AND THE LAST 3 PIPE SECTIONS ON THE APRON SHALL BE TIED WITH RF-14 TYPE II CONNECTORS. ALL APRONS SHALL HAVE A STANDARD FOOTING AND TRASH GUARD. 20.ALL SUMP SERVICE LINES SHALL HAVE TRACE WIRE WATER SERVICE NOTES 21.WATER SERVICE SHALL BE TYPE K COPPER, DIP OR HDPE, DEPENDING ON SIZE AND JURISDICTIONAL REQUIREMENTS. IF CONTAMINATED OR "HOT" SOILS, ENSURE APPROPRIATE PIPE IS BEING UTILIZED. SIZE OF WATER MAIN AS SHOWN ON PLANS. 22.TRACER WIRE SHALL BE ADDED TO ALL WATER MAIN, AND BROUGHT TO THE SURFACE AT EVERY HYDRANT. 23.THRUST BLOCKS SHALL BE INSTALLED AS REQUIRED AND SHALL BE CONSIDERED INCIDENTAL TO WATER MAIN CONSTRUCTION. 24.ANY AND ALL HYDRANT AND VALVE EXTENSIONS, TOGETHER WITH VERTICAL BENDS, SHALL BE CONSIDERED INCIDENTAL TO WATER MAIN CONSTRUCTION. NO ADDITIONAL PAYMENT WILL BE PROVIDED FOR INCIDENTAL ITEMS. 25.ALL WATER LINES SHALL HAVE A MINIMUM OF 5.5 FEET OF COVER UNLESS NOTED OTHERWISE. EXISTING UTILITIES NOTE 1.THE LOCATIONS OF THE EXISTING UTILITIES SHOWN HEREON ARE APPROXIMATE. THEY HAVE BEEN PLOTTED FROM AVAILABLE SURVEYS AND/OR RECORDS. THE CONTRACTOR IS RESPONSIBLE TO ENSURE THAT ANY EXISTING UTILITIES (SHOWN OR NOT SHOWN) ARE NOT DAMAGED DURING CONSTRUCTION: IOWA ONE-CALL (1-800-292-8989). UTILITY CONFLICT NOTES 1.UTILITY CONFLICTS MAY EXIST ACROSS THE SITE WITH NEW UTILITIES, GRADING, PAVING ETC. MOST UTILITY CONFLICTS HAVE BEEN CALLED OUT FOR CONTRACTOR CONVENIENCE. 2.CONTRACTOR IS RESPONSIBLE FOR ALL UTILITY CONFLICTS BETWEEN AN EXISTING UTILITY AND PROPOSED CONSTRUCTION THAT ARE EITHER CALLED OUT ON THE PLANS OR NOT CALLED OUT. 3.CONTRACTOR SHALL COMPLY WITH ALL DNR REQUIREMENTS FOR PIPE MATERIAL, PIPE JOINTS, AND ANY OTHER APPLICABLE REQUIREMENTS ANY TIME A STORM SEWER OR SANITARY SEWER CROSSES OVER OR LESS THAN 18" BELOW A WATER MAIN. 4.FOR ALL CRITICAL CROSSINGS WITH EXISTING UTILITIES, THE ELEVATION OF THE EXISTING UTILITY SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. NOTIFY PELDS DESIGN SERVICES PRIOR TO CONSTRUCTION IF A CONFLICT EXISTS. SPECIFICATIONS NOTES 1.ALL WORK SHALL BE DONE IN ACCORDANCE WITH SUDAS 2022 AND 2020 WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS. 2.IN THE EVENT OF A DISCREPANCY BETWEEN THE PROJECT SPECIFICATIONS AND THE CITY OF WAUKEE REQUIREMENTS AND SPECIFICATIONS, PLUMBING CODE, AND URBAN STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENT, THE CITY OF WAUKEE STANDARD SPECIFICATIONS SHALL GOVERN. 3.FOR ALL SPECIFICATION DISCREPANCIES, THE PROJECT ENGINEER SHALL BE CONTACTED PRIOR TO PROCEEDING WITH CONSTRUCTION. IF THE ENGINEER IS NOT CONTACTED, CONTRACTOR SHALL BE RESPONSIBLE FOR ANY PROBLEMS THAT RESULT FROM SAID DISCREPANCIES. REQUIRED AS-BUILT NOTES 1.THE CONTRACTOR SHALL BE RESPONSIBLE FOR COST OF AS-BUILT TOPO, WHICH IS REQUIRED BY THE CITY. 2.CONTRACTOR SHALL CONTACT PELDS DESIGN SERVICES TO PERFORM SAID AS-BUILT SURVEYS. 3.IF ANYTHING HAS BEEN CONSTRUCTED INCORRECTLY, CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SUBSEQUENT AS-BUILT SURVEYS UNTIL ISSUES HAVE BEEN RECTIFIED. FIRE SAFETY CONSTRUCTION NOTE 1.APPROVED FIRE APPARATUS ACCESS ROADS SHALL BE PROVIDED AS SOON AS CONSTRUCTION COMMENCES. IF PAVING IS NOT INSTALLED PRIOR TO BUILDING CONSTRUCTION COMMENCING AFTER FOOTINGS ARE INSTALLED, AN APPROVED ROUTE AROUND THE EXTERIOR OF THE BUILDING TO EXTEND WITHIN 100-FEET OF ALL PORTIONS OF THE EXTERIOR WALLS SHALL BE PROVIDED AND COMPLY WITH THE REQUIREMENTS OF SECTION 503.2 OF THE IFC. GENERAL NOTES 1.THE CITY OF WAUKEE MUST BE NOTIFIED BY ALL CONTRACTORS 48 HOURS PRIOR TO COMMENCING WORK. 2.ALL PROPOSED MATERIALS AND STRUCTURES SHALL BE APPROVED BY THE CITY OF WAUKEE AND BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS 3.ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE CURRENT O.S.H.A. CODES AND STANDARDS. NOTHING INDICATED ON THESE PLANS SHALL RELIEVE THE CONTRACTOR FROM COMPLYING WITH THE APPROPRIATE SAFETY REGULATIONS. 4.ALL NECESSARY CONSTRUCTION SIGNS, BARRICADES AND OTHER TRAFFIC CONTROL DEVICES REQUIRED DURING CONSTRUCTION WILL BE FURNISHED BY THE CONTRACTOR. SIGNS, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES MUST BE IN CONFORMANCE WITH THE "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS." 5.PELDS DESIGN SERVICES SHALL NOT BE LIABLE FOR ANY INJURIES THAT HAPPEN ON SITE. THIS SHALL INCLUDE BUT NOT BE LIMITED TO TRENCH COLLAPSES FROM VARYING SOIL CONDITIONS OR INJURIES CAUSED BY UNDERGROUND UTILITIES INCLUDING UTILITIES THAT ARE NOT SHOWN ON PLAN. 6.THE CONTRACTOR IS LIABLE FOR ALL DAMAGES TO PUBLIC OR PRIVATE PROPERTY CAUSED BY THEIR ACTION OR INACTION IN PROVIDING FOR STORM WATER FLOW DURING CONSTRUCTION. DO NOT RESTRICT FLOWS IN EXISTING DRAINAGE CHANNELS, STORM SEWER, OR FACILITIES. 7.A PRE-CONSTRUCTION MEETING IS REQUIRED PRIOR TO THE START OF CONSTRUCTION; THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE THIS MEETING. 8.LABORATORY TESTS SHALL BE PERFORMED BY THE OWNER UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL PROVIDE SAMPLES OF MATERIAL REQUIRED FOR LABORATORY TESTS AND TESTING IN ACCORDANCE WITH THE URBAN STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS. 9.THE CONTRACTOR SHALL PROTECT ALL STRUCTURES NOT SHOWN AS REMOVALS ON THE PLANS. 10.THE CONTRACTOR SHALL OBTAIN ANY AND ALL NECESSARY PERMITS PRIOR TO ANY CONSTRUCTION. CONTRACTOR SHALL WORK WITH OWNER OR OWNER'S REPRESENTATIVE ON ALL REQUIRED STORM WATER DISCHARGE PERMITS FROM THE IOWA DEPARTMENT OF NATURAL RESOURCES AND THE CITY OF WAUKEE. 11.THE CONTRACTOR SHALL PICK UP ANY DEBRIS SPILLED ONTO THE ADJACENT RIGHT OF WAY OR ABUTTING PROPERTIES AS THE RESULT OF CONSTRUCTION, AT THE END OF EACH WORK DAY AND PRIOR TO A RAIN EVENT. 12.THE CONTRACTOR IS RESPONSIBLE FOR THE PROMPT REMOVAL OF ALL MUD THAT HAS BEEN TRACKED OR WASHED UNTO ADJACENT PROPERTY OR RIGHT OF WAY UNTIL SUCH TIME THAT PERMANENT VEGETATION HAS BEEN ESTABLISHED. 13.DISPOSE OF ALL EXCESS MATERIALS AND TRASH IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL REQUIREMENTS. PROVIDE WASTE AREAS OR DISPOSAL SITES OR EXCESS MATERIALS NOT DESIRABLE FOR INCORPORATION INTO THE PROJECT. 14.ALL CONSTRUCTION WITHIN THE PUBLIC R.O.W/EASEMENTS, AND/OR ANY CONNECTION TO PUBLIC SEWERS AND STREETS SHALL COMPLY WITH THE CITY OF WAUKEE. 15.THE CONTRACTOR SHALL CONTACT THE CITY OF WAUKEE TO SCHEDULE ANY REQUIRED INSPECTIONS AT LEAST ONE WEEK PRIOR TO ANY CONSTRUCTION WITHIN PUBLIC R.O.W/EASEMENTS, AND/OR ANY CONNECTION TO PUBLIC SEWERS AND STREETS 16.IN THE EVENT OF ANY CONFLICTING NOTES BETWEEN THE COVER SHEET AND ALL OTHER SHEETS, THE NOTES ON THE COVER SHEET SHALL SUPERCEDE ALL OTHERS 17.IN THE EVENT OF ANY CONFLICTING INFORMATION BETWEEN THE LABEL, ELECTRONIC CAD FILE, AND THE ELECTRONIC SURFACE, THE DESIGN ENGINEER SHALL BE CONTACTED FOR CLARIFICATION SURVEY NOTES 1.SURVEY WORK WAS COMPLETED BY PELDS DESIGN SERVICES IN MARCH 2022. SEE SITE SURVEY PROVIDED AS PART OF THIS SET OF PLANS FOR EXISTING SITE CONDITIONS AND BOUNDARY INFORMATION. STAKING NOTES 1.IT IS RECOMMENDED FOR THE CONTRACTOR TO HAVE ALL STAKING DONE UNDER THE SUPERVISION OF A LICENSED LAND SURVEYOR AND IN COORDINATION WITH THE PROJECT ENGINEER. 2.IT IS RECOMMENDED FOR THE CONTRACTOR TO HAVE ALL STAKING DONE DIRECTLY UNDER THE GENERAL CONTRACTOR BY A SINGLE COMPANY. 3.STAKING DOES NOT RELIEVE CONTRACTOR OF ULTIMATE RESPONSIBILITY TO CONSTRUCT THE PROJECT PER PLAN. DEMO NOTES 1.SAWCUT & REMOVE ALL PAVEMENT TO FULL DEPTH OF SLAB. 2.PROTECT ALL TREES NOT CALLED OUT FOR REMOVAL WITH ORANGE CONSTRUCTION FENCE AT THE DRIP LINE. 3.PAVEMENT STRIPING CALLED OUT FOR REMOVAL SHALL BE SANDBLASTED. NO GRINDING WILL BE ALLOWED. 4.PROPERLY DISCONNECT ALL PUBLIC AND PRIVATE UTILITIES, AS NECESSARY. 5.COMPLY WITH LOCAL, STATE, AND FEDERAL REGULATIONS TO REMOVE AND PROPERLY DISPOSE OF SIDEWALKS, STEPS, DRIVEWAYS, AND STRUCTURES (INCLUDING BOTH ABOVE GROUND AND BELOW GROUND ELEMENTS). 6.COMPLY WITH LOCAL, STATE, AND FEDERAL REGULATIONS TO REMOVE FUEL TANKS, SEPTIC TANKS, CISTERNS, AND ANY OTHER UNDERGROUND FACILITIES; AND TO PROPERLY DISPOSE OF ANY LIQUIDS OR PRODUCTS CONTAINED WITHIN THESE ITEMS. 7.PLACE BACKFILL MATERIAL IN HOLES AND DEPRESSIONS, GRADE THE SITE, AND ESTABLISH GROUND COVER. 8.PROTECT EXISTING FIRE HYDRANTS, STREET LIGHTS, TRAFFIC SIGNALS, UTILITY POLES, FIRE ALARM BOXES, WIRE CABLES, UNDERGROUND UTILITIES, AND OTHER APPURTENANCES IN THE VICINITY OF THE DEMOLITION SITE 9.COMPLY WITH NOISE POLLUTION REQUIREMENTS AND ANY WORKING HOUR RESTRICTIONS OF THE JURISDICTION. 10.MAINTAIN OR RE-ESTABLISH ALL TILES, ROADWAY SUBDRAINS, CULVERTS, OR OTHER DRAINAGE FACILITIES NOT IDENTIFIED IN THE CONTRACT DOCUMENTS FOR REMOVAL. 11.IMPLEMENT THE APPROVED EROSION AND SEDIMENT CONTROL PLAN FOR EACH SITE PRIOR TO INITIATING DEMOLITION BY PLACING ALL REQUIRED DEVICES; INCLUDE MEASURES TO PREVENT TRACKING OF MUD ONTO ADJACENT STREETS OR ALLEYS. 12.COMPLY WITH ALL APPLICABLE AIR POLLUTION REQUIREMENTS OF THE JURISDICTION. USE WATER OR APPROPRIATE CHEMICALS FOR CONTROL OF DUST IN THE DEMOLITION AREA, ON HAULING EQUIPMENT, ON ADJACENT ROADWAYS, AND WHEN GRADING THE SITE. 13.TAKE STEPS TO PREVENT THE GENERATION OF LITTER DURING DEMOLITION AND COLLECT ALL LITTER FROM THE DEMOLITION AREA AT THE END OF EACH WORKING DAY. LOAD TRUCKS TO PREVENT LEAKAGE OR BLOWING OF DEBRIS. 14.REMOVE ALL CONCRETE, ASPHALT, OR MASONRY SLABS AND APPURTENANCES. 15.REMOVE AND DISPOSE OF ALL BRUSH, SHRUBS, TREES, LOGS, DOWNED TIMBER, AND OTHER YARD WASTE ON THE SITE UNLESS OTHERWISE SPECIFIED IN THE CONTRACT DOCUMENTS. DO NOT MIX WITH DEMOLITION MATERIAL. REMOVE STUMPS TO A MINIMUM OF 2 FEET BELOW FINISH GRADE. PROTECT ANY TREES OR OTHER VEGETATION NOT DESIGNATED FOR REMOVAL BY PLACING A FENCE AT THE DRIP LINE ENCOMPASSING THE ENTIRE TREE AND KEEPING ALL OPERATIONS OUTSIDE OF THE FENCED IN AREA, INCLUDING STORAGE OF EQUIPMENT OR MATERIALS. AT NO ADDITIONAL COST TO THE CONTRACTING AUTHORITY, REPLACE ANY TREES THAT ARE DESIGNATED FOR PROTECTION BUT ARE DAMAGED BEYOND TREATMENT. THE ENGINEER WILL DETERMINE SIZE AND SPECIES OF THE REPLACEMENT TREE. 16.SAW-CUT ALL HARD SURFACING AT LOCATION OF REMOVAL LIMITS. 17.WHERE SELECTIVE DEMOLITION IS SHOWN AT PAVED AREAS, DEMOLISH THE EXISTING PAVING BACK TO AN EXISTING CONTROL JOINT NEAR THE LOCATION SHOWN. WETLAND NOTES 1.PELDS DESIGN SERVICES DOES NOT PERFORM WETLAND STUDIES OR WETLAND MITIGATION. IT IS THE OWNER'S RESPONSIBILITY TO DETERMINE IF ANY WETLANDS ARE LOCATED ON THE PROJECT SITE AND PERFORM ANY NECESSARY MITIGATION PRIOR TO THE COMMENCEMENT OF CONSTRUCTION ACTIVITIES. DISCLAIMER 1.THIS DRAWING IS BEING MADE AVAILABLE BY PELDS DESIGN SERVICES (P.D.S.) FOR USE ON THIS PROJECT IN ACCORDANCE WITH P.D.S.'S AGREEMENT FOR PROFESSIONAL SERVICES. P.D.S. ASSUMES NO RESPONSIBILITY OR LIABILITY (CONSEQUENTIAL OR OTHERWISE) FOR ANY USE OF THESE DRAWINGS (OR ANY PART THEREOF) EXCEPT IN ACCORDANCE WITH THE TERMS OF SAID AGREEMENT. 2.P.D.S DISCLAIMS ANY AND ALL LIABILITY OR RESPONSIBILITY FOR INFORMATION THAT DOES NOT BEAR THE ORIGINAL SEAL AND SIGNATURE OF THE PROFESSIONAL IN CHARGE. BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: C-002 - NOTE SHEET 10-04-22 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: B. SHORT J:\2022 Projects\22-001 - Guadalajara Restaurant - Waukee\Engineering\Site Plan\Sheet Set WAUKEE, IOWA GUADALAJARA RESTAURANT 185 W HICKMAN RD TITLE: ----22-001 PRELIMINARY CIVIL ENGINEERING NOTES 1015 1015 10 2 0 1020 1016 1016 1017 1017 10 1 8 1018 10 1 9 1019 1 0 2 1 1021 1 0 2 2 1022 1 0 2 2 102 3 1 0 2 3 102 4 10 2 4 1 0 2 0 10 2 5 10 2 5 10 3 0 10 3 0 1 0 2 1 10 2 2 10 2 3 10 2 4 10 2 4 10 2 6 10 2 6 10 2 7 10 2 7 10 2 8 10 2 8 10 2 9 10 2 9 1025 1025 1021 10 2 1 1022 102 2 1023 10 2 3 1024 1024 10 2 4 1024 1026 1026 10 2 5 10 2 2 10 2 3 10 2 4 10 2 6 10 2 7 10 2 8 10 2 9 LOT 1 WAUKEE CROSSING PLAT 4LOT 2 LOT 6 1025 1022 1023 1024 1026 1027 1027 1 0 2 1 1 0 2 2 10 2 2 1 0 2 2 1 0 2 3 TSE Hickman Rd FOV Sanitary Manhole Rim: 1023.82 FL: 1,000.95 Sanitary Manhole Rim:1022.28 FL:1003.28 Sanitary Manhole Rim: 1022.26 FL: 1003.95 Storm Sewer Rim: 1025.18 Storm Sewer Rim: 1024.55 One Way One Way Yield Turn Lane Stop FOUND LOT "X" 16.5' TELECOMMUNICATIONS EASEMENT - APPROXIMATE LOCATION (BK 709 PG 455) N89° 31' 19"W 649.42' N89° 31' 19"W 245.57' S45 ° 2 6 ' 4 9 " W 4 9 . 4 0 ' S0 ° 2 0 ' 1 6 " W 1 8 4 . 8 8 ' 10' PUE 10 ' P U E E WE WE WE WE W E W E W E W E W E W E W E W E WHYDRANT TO BE REMOVED BY OTHERSE W E WE WE WE WE WE WE WE WE WE WE WE WE W E SAN E SAN E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E SANE SANE SANE SANE SANE SANE SANE SANE SANE SANE SANE SANE SANE SANE SAN E S A N E S A N E SANE SANE SANE SANE SANE SANE SANE SANE SANE SANE SANE SANE SAN NW 2 N D S T 10 0 ' R O W Turn Lane REMOVE AND RELOCATE SIGN RELOCATE SIGN CURB REMOVAL ~ 68 LF CURB REMOVAL ~ 75 LF LUMEN UG E UG E UG E UGE UGE E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO UPN FIBER E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO AUREON FIBER E WE WE WE WE WE WE WE WE WE WE WE WE W E W E W E W E W FOUND 5/8" DIA. REBAR W/ BLUE CAP #18381 10' PUE 10' GAS MAIN EASEMENT 10 ' P U E 5' PARKING SETBACK 5' P A R K I N G S E T B A C K 10' PARKING SETBACK 10 ' P A R K I N G S E T B A C K 30' FRONT SETBACK 30 ' F R O N T S E T B A C K PUBLIC STORM SEWER EASEMENT BK 2020 PG 1343 S89° 31' 19"E 217.59' 10' PUE R=300.01 D=11°48'10" L=61.80 T =31.01 Ch =61.69 ChB =S5° 33' 11"E D=11.8028 WATER SERVICE WITH BLOWOFF BY OTHERS XENIA WATER FIRE HYDRANT BY OTHERS 6" SANITARY STUB BY OTHERS 20' PRIVATE WATER MAIN EASEMENT BK 2020 PG 1346 20' STORM SEWER EASEMENT 8" WATER MAIN BY OTHERS REMOVAL AREA ~ 72 SY REMOVAL AREA ~ 74 SY 1025.741025.77 S0 ° 2 8 ' 4 1 " W 2 8 1 . 1 8 ' CLEANOUT TO BE REMOVED BY OTHERS E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE U G E U G E U G E U G E UG E UG E UG E UG E UG E U G E U G E U G E U G E U G E U G E E GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GAS E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T 6" SUBDRAIN 8" SANITARY SEWER BY OTHERS OWNER: WAUKEE CROSSING, LLC ZONING: C-1 OW N E R : W A U K E E C R O S S I N G , L L C ZO N I N G : C - 1 OW N E R : C I T Y O F W A U K E E OWNER: IOWA DOT OW N E R : H Y - V E E , I N C ZO N I N G : C - 1 O W N E R : W A U K E E C R O S S I N G , L L C Z O N I N G : C - 1 ST ST E STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE ST 18" STORM15" STORM 18" STORM E ST E ST E ST E ST E ST 15" STORM 8" SAN8" SAN 8" SAN 8" S A N 8" S A N 18" SAN 8" WATER E GAS E GAS E GAS E GAS E GAS E GAS E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S FOUND 5/8" DIA. REBAR W/ BLUE CAP #18381 FOUND 5/8" DIA. REBAR W/BLUE CAP #18381 PRIVATE MONUMENT SIGN EASEMENT (BK 2020 PG 1349) PUBLIC SANITARY SEWER EASEMENT BK 2020 PG 1340 1022.16 4" GAS 1" G A S 1023.67 1024.47 1025.20 1020 1020 1017 1017 1018 1018 1019 1019 1021 1022 1023 1024 E STE STE STE ST 20' STORM SEWER EASEMENT PUBLIC SANITARY SEWER EASEMENT BK 2020 PG 1340 PROPOSED PRIVATE SEWER EASEMENT PUBLIC WATER MAIN EASEMENT BK 2020 PG 1346 1022.76 EXISTING PAVEMENT PAVEMENT REMOVALS PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: C-101 - TOPO SHEET 10-04-22 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: B. SHORT J:\2022 Projects\22-001 - Guadalajara Restaurant - Waukee\Engineering\Site Plan\Sheet Set WAUKEE, IOWA GUADALAJARA RESTAURANT 185 W HICKMAN RD TITLE: ----22-0011"=20' PRELIMINARY LEGEND: GUY ANCHOR ELEC. TRANSFORMER ELEC. METER ELEC. BOX ELEC. VAULT GAS METER UTILITY PEDESTAL CABLE TV JUNCTION BOX SIGN PARKING SPACE STREET LIGHT POWER POLE LIGHT POLE MORE OR LESS GUTTER ELEVATION TOP OF CURB ELEVATION +/- EXISTING/ PROPOSED ELEVATION 123.45G 123.45TC FLOWLINE ELEVATIONFL FINISHED FLOORF.F. WATER METER 123.45123.45/ CALCULATED SECTION CORNER FOUND SECTION CORNER CALCULATED CORNER FOUND CORNER AREA LIGHT CONTROL POINT FIBER OPTIC VAULT SINGLE INTAKE WATER VALVE FLARED END SECTION ELEC. MANHOLE GAS VALVE FIBER OPTIC FENCE LINE FIRE HYDRANT SANITARY SEWER MANHOLE WATER GAS LINE SANITARY SEWER STORM SEWER UNDERGROUND TEL. OVERHEAD TEL. W ST UGT OHT CABLE TELEVISIONCATV GAS SS STORM SEWER MANHOLE PROPOSED UTILITY LINEP XX CLEANOUT DOWNSPOUTD UNDERGROUND ELEC.UGE OVERHEAD ELEC.OHE EXISTING UTILITY LINEE XX FO THROAT INTAKE AREA INTAKE TRAFFIC MANHOLE PROTECT UTILITIES PROTECT UTILITIES PROTECT TREES PR O T E C T U T I L I T I E S NOTES: 1.CONTOURS SHOWN AS EXISTING ARE COMBINED FROM PDS' SURVEY AND FROM THE PRE-PLAT SURFACE PER CEC PLAN DATED 08-15-2022. Hickman Rd One Way One Way Yield Yield Stop FOUND LOT "X" N89° 31' 19"W 649.42' N89° 31' 19"W 245.57' S45 ° 2 6 ' 4 9 " W 4 9 . 4 0 ' S0 ° 2 0 ' 1 6 " W 1 8 4 . 8 8 ' 6.00 6.00 31.87 RESTAURANT 7,307 SQ. FT. FF: 1024.00 COVERED PATIO 25.00 24.00 24 . 0 0 24.00 24 . 0 0 R15 . 0 0 R 5 . 0 0 R4. 0 0 R 5 . 0 0 R12 . 0 0 R 5 . 0 0 R5.0 0 R 1 5 . 0 0 R5.0 0 R5.0 0 R 5 . 0 0 R5.0 0 R3 3 . 7 9 R2. 5 0 R15. 0 0 R 5 . 0 0 R15.00 R 5 . 0 0 R2 0 . 0 0 R 1 0 . 0 0 R5.0 0 R 5 . 0 0 R5.00 R 1 5 . 0 0 R25.00 R5. 0 0 R5 . 0 0 R 5 . 0 0 R 1 0 . 0 0 R 5 . 0 0 R2.50 R 2 . 5 0 R 2 . 0 0 R2 . 0 0 17 . 0 0 9.00 17.00 8. 0 0 5. 0 0 8. 0 0 8. 0 0 8. 0 0 5. 0 0 8. 0 0 17 . 0 0 9.00 9.00 19 . 0 0 19 . 0 0 9.00 17 . 0 0 9.00 17.00 9. 0 0 9. 0 0 9. 0 0 17.00 97.59 74 . 3 6 46.02 19 . 9 6 45.53 19 . 2 6 24.00 R15.00 R 2 0 . 0 0 NW 2 N D S T 10 0 ' R O W Turn Lane RELOCATE SIGN 10.00 4.259.67 10.00 FOUND 5/8" DIA. REBAR W/ BLUE CAP #18381 5' PARKING SETBACK 5' P A R K I N G S E T B A C K 10' PARKING SETBACK 10 ' P A R K I N G S E T B A C K 30' FRONT SETBACK 30 ' F R O N T S E T B A C K S89° 31' 19"E 217.59' 17.009. 0 0 9 S P A C E S 10 SPA C E S 10 SPA C E S 16 SPA C E S 10 SPA C E S 7 SPAC E S 4 SPAC E S 9 S P A C E S 9 SPAC E S 10 S P A C E S 10 S P A C E S 6 S P A C E S R=300.01 D=11°48'10" L=61.80 T =31.01 Ch =61.69 ChB =S5° 33' 11"E D=11.8028 61 . 0 0 74.20 14 2 . 3 2 80.39 7' SIDEWALK S0 ° 2 8 ' 4 1 " W 2 8 1 . 1 8 ' OWNER: WAUKEE CROSSING, LLC ZONING: C-1 OW N E R : W A U K E E C R O S S I N G , L L C ZO N I N G : C - 1 OW N E R : C I T Y O F W A U K E E OWNER: IOWA DOT OW N E R : H Y - V E E , I N C ZO N I N G : C - 1 O W N E R : W A U K E E C R O S S I N G , L L C Z O N I N G : C - 1 T Y P E A D R I V E W A Y TY P E A D R I V E W A Y PE R M A N E N T R I G H T - I N / R I G H T - O U T M I N . 6 " P C C ( T Y P ) TRASH ENCLOSURE 11 . 0 0 FOUND 5/8" DIA. REBAR W/ BLUE CAP #18381 FOUND 5/8" DIA. REBAR W/BLUE CAP #18381 R3.0 0 R 1 . 5 0 R1.5 0 R 5 . 0 0 R5.0 0 24 . 0 0 R1 5 . 0 0 R 1 5 . 0 0 R2 5 . 0 0 24 . 0 0 PROPOSED 6" PCC 38,590 SQ. FT. EXISTING PAVEMENT PROPOSED BUILDING 7,307 SQ. FT. PROPOSED 4" PCC SIDEWALK PROPOSED OPEN SPACE 14,285 SQ. FT. PROPOSED 8" PCC (ENTRANCE & TRUCK ROUTE) 8,535 SQ. FT. NOTES: 1.TRAIL PAVEMENT SHALL BE MINIMUM 6" PCC. 2.SITE LIGHTING MUST BE APPROVED BY CITY PRIOR TO INSTALLATION. PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: C-102 - SITE SHEET 10-04-22 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: B. SHORT J:\2022 Projects\22-001 - Guadalajara Restaurant - Waukee\Engineering\Site Plan\Sheet Set WAUKEE, IOWA GUADALAJARA RESTAURANT 185 W HICKMAN RD TITLE: ----22-0011"=20' PRELIMINARY LEGEND: GUY ANCHOR ELEC. TRANSFORMER ELEC. METER ELEC. BOX ELEC. VAULT GAS METER TEL. JUNCTION BOX CABLE TV JUNCTION BOX SIGN PARKING SPACE STREET LIGHT POWER POLE LIGHT POLE MORE OR LESS GUTTER ELEVATION TOP OF CURB ELEVATION +/- EXISTING/ PROPOSED ELEVATION 123.45G 123.45TC FLOWLINE ELEVATIONFL FINISHED FLOORF.F. WATER METER 123.45123.45/ CALCULATED SECTION CORNER FOUND SECTION CORNER CALCULATED CORNER FOUND CORNER AREA LIGHT CONTROL POINT FIBER OPTIC VAULT SINGLE INTAKE WATER VALVE FLARED END SECTION ELEC. MANHOLE GAS VALVE FIBER OPTIC FENCE LINE FIRE HYDRANT SANITARY SEWER MANHOLE WATER GAS LINE SANITARY SEWER STORM SEWER UNDERGROUND TEL. OVERHEAD TEL. W ST UGT OHT CABLE TELEVISIONCATV GAS SS STORM SEWER MANHOLE PROPOSED UTILITY LINEP XX CLEANOUT DOWNSPOUTD UNDERGROUND ELEC.UGE OVERHEAD ELEC.OHE EXISTING UTILITY LINEE XX FO THROAT INTAKE AREA INTAKE TRAFFIC MANHOLE 30" Minimum 4.5"3" PROPOSED P.C.C. PAVEMENT / CURB TSE Hickman Rd FOV Sanitary Manhole Rim: 1023.82 FL: 1,000.95 Sanitary Manhole Rim:1022.28 FL:1003.28 Sanitary Manhole Rim: 1022.26 FL: 1003.95 Storm Sewer Rim: 1025.18 Storm Sewer Rim: 1024.55 16.5' TELECOMMUNICATIONS EASEMENT - APPROXIMATE LOCATION (BK 709 PG 455) RESTAURANT 7,307 SQ. FT. FF: 1024.00 COVERED PATIO 10' PUE 10 ' P U E E WE WE WE WE W E W E W E W E W E W E W E W E W E W E WE WE WE WE WE WE WE WE WE WE WE WE W E SAN E SAN E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E SANE SANE SANE SANE SANE SANE SANE SANE SANE SANE SANE SANE SANE SANE SAN E S A N E S A N E SANE SANE SANE SANE SANE SANE SANE SANE SANE SANE SANE SANE SAN NW 2 N D S T 10 0 ' R O W LUMEN E U G E E U G E E U G E E UGE E UGE E UGE E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO UPN FIBER E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO AUREON FIBER E WE WE WE WE WE WE WE WE WE WE WE WE W E W E W E W E W 10' PUE 10' GAS MAIN EASEMENT 10 ' P U E PUBLIC STORM SEWER EASEMENT BK 2020 PG 1343 10' PUE WATER SERVICE WITH BLOWOFF BY OTHERS XENIA WATER FIRE HYDRANT BY OTHERS ST 6" SANITARY STUB BY OTHERS 20' PRIVATE WATER MAIN EASEMENT BK 2020 PG 1346 20' STORM SEWER EASEMENT 8" WATER MAIN BY OTHERS CONNECT DOWNSPOUTS CONNECT DOWNSPOUTS E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E U G E E U G E E U G E E U G E E U G E E U G E E U G E E U G E E U G E E U G E E U G E E U G E E GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GAS E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T 6" SUBDRAIN 8" SANITARY SEWER BY OTHERS PROPOSED TRANSFORMER AND MOAT OWNER: WAUKEE CROSSING, LLC ZONING: C-1 OW N E R : W A U K E E C R O S S I N G , L L C ZO N I N G : C - 1 OW N E R : C I T Y O F W A U K E E OWNER: IOWA DOT OW N E R : H Y - V E E , I N C ZO N I N G : C - 1 O W N E R : W A U K E E C R O S S I N G , L L C Z O N I N G : C - 1 TRASH ENCLOSURE P S T P S T P S T P S T P S T P S T P S T P S T P S T P S T P S T P S T P S T P STP STP ST P ST P ST P S T P S T P S T P S T P S T P S T P STP STP STP ST ST ST E STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE ST 18" STORM15" STORM 18" STORM E ST E ST E ST E ST 15" STORM 8" SAN8" SAN 8" SAN 8" S A N 8" S A N 18" SAN 8" WATER E GAS E GAS E GAS E GAS E GAS E GAS E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S PRIVATE MONUMENT SIGN EASEMENT (BK 2020 PG 1349) PUBLIC SANITARY SEWER EASEMENT BK 2020 PG 1340 4" GAS 1" G A S FIRE DEPARTMENT CONNECTIONFIRE SPRINKLER RISER ROOM P GAS P GAS P GAS P GAS P GAS P GASGAS SERVICE 6" FIRE SERVICE 2" DOMESTIC WATER SERVICE SEE MECHANICAL CRITICAL CROSSING 1 CRITICAL CROSSING 3 P5 4 6 L F 6 " H D P E @ 3 . 0 0 % P6 8 1 L F 6 " H D P E @ 2 . 0 0 % P7 101LF 6" HDPE @ 1.30% P8 6 8 L F 6 " H D P E @ 1 . 3 0 % STM 2 SW-511 GRATE:1021.10 FL IN:1017.72 6" NE FL OUT:1017.62 15" N MANHOLE BY OTHERS SW-401 RIM:1023.20 FL IN:1016.04 15" S FL IN:1014.70 15" E FL OUT:1014.58 18" W P 2 1 5 8 L F 1 5 " H D P E @ 1 . 0 0 % STM 3 SW-501 GRATE:1021.80 FL IN:1015.16 12" SE FL OUT:1015.06 15" W P4 1 4 7 L F 1 2 " H D P E @ 0 . 3 0 % P3 89LF 15" RCP @ 0.40% STM 5 CO RIM:1023.37 FL IN:1019.21 6" N FL IN:1019.21 6" E FL OUT:1019.11 6" SW STM 6 CO RIM:1023.91 FL OUT:1020.83 6" S STM 8 CO RIM:1023.97 FL OUT:1021.50 6" S STM 7 CO RIM:1023.85 FL IN:1020.62 6" N FL OUT:1020.52 6" W STM 4 SW-501 GRATE:1022.48 FL OUT:1015.60 12" NW E STE STE STE ST 20' STORM SEWER EASEMENT PUBLIC SANITARY SEWER EASEMENT BK 2020 PG 1340 PROPOSED PRIVATE SEWER EASEMENT PUBLIC WATER MAIN EASEMENT BK 2020 PG 1346 CRITICAL CROSSING 4 CRITICAL CROSSING 2 P S A N E WE WE WE WE W E S A N P S T P S T P S T P G A S P GAS P S A N FL = 1019.76 FL = 1019.51 CONNECT TO STUB FL ≈ 1008.50 (FIELD VERIFY) FL = 1020.00 P S A N 6" SAN 12 LF @ 2% P S A N P S A N FL = 1019.45 45° BENDS 6" SAN 27.5 LF @ 2% INSTALL SERVICE RISER (~11.5' @ 1:1 SLOPE) 2 LF @ 3% NOTES: 1.SITE LIGHTING MUST BE APPROVED BY THE CITY PRIOR TO INSTALLATION. PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: C-103 - UTILITY SHEET 10-04-22 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: B. SHORT J:\2022 Projects\22-001 - Guadalajara Restaurant - Waukee\Engineering\Site Plan\Sheet Set WAUKEE, IOWA GUADALAJARA RESTAURANT 185 W HICKMAN RD TITLE: ----22-0011"=20' PRELIMINARY LEGEND: GUY ANCHOR ELEC. TRANSFORMER ELEC. METER ELEC. BOX ELEC. VAULT GAS METER UTILITY PEDESTAL CABLE TV JUNCTION BOX SIGN PARKING SPACE STREET LIGHT POWER POLE LIGHT POLE MORE OR LESS GUTTER ELEVATION TOP OF CURB ELEVATION +/- EXISTING/ PROPOSED ELEVATION 123.45G 123.45TC FLOWLINE ELEVATIONFL FINISHED FLOORF.F. WATER METER 123.45123.45/ CALCULATED SECTION CORNER FOUND SECTION CORNER CALCULATED CORNER FOUND CORNER AREA LIGHT CONTROL POINT FIBER OPTIC VAULT SINGLE INTAKE WATER VALVE FLARED END SECTION ELEC. MANHOLE GAS VALVE FIBER OPTIC FENCE LINE FIRE HYDRANT SANITARY SEWER MANHOLE WATER GAS LINE SANITARY SEWER STORM SEWER UNDERGROUND TEL. OVERHEAD TEL. W ST UGT OHT CABLE TELEVISIONCATV GAS SS STORM SEWER MANHOLE PROPOSED UTILITY LINEP XX CLEANOUT DOWNSPOUTD UNDERGROUND ELEC.UGE OVERHEAD ELEC.OHE EXISTING UTILITY LINEE XX FO THROAT INTAKE AREA INTAKE TRAFFIC MANHOLE TRANSFORMER PAD GATE SEE NOTE 4 10' - 0" MIN. SEE NOTE 4 3' - 0" MIN. SEE NOTE 4 3" RIVER ROCK BUILDING WALL, BARRIER WALL OR SCREENING STRUCTURE. SEE NOTE 3 FRONT OF PAD PRIMARY SECONDARY PAD REINFORCEMENT MOAT SEE NOTE 9 3' - 0" MIN. GROUND ROD SLEEVE 1" METERING CONDUIT MAY BE REQUIRED CABLE CONDUIT BOX-OUTS. CONDUITS SHALL BE CENTERED ALONG THE BACK EDGE WITHIN BOX-OUTS TRAFFIC PROTECTION POSTS (BY CUSTOMER-AS REQUESTED BY COMPANY) SEE NOTE 7 7' - 4" 6' - 6" Three-phase transformer pads must be: 1. Installed by the customer at the customer's expense. Ongoing maintenance and repair to the pad are the responsibility of the customer. 2. Constructed in a manner satisfactory to the Company, in a mutually agreed upon location with hard surface access and unobstructed work space for large vehicles. 3. The installation of a screening or barrier structure may be required by your local governing authority. It is the customer’s responsibility to determine if a barrier structure is required. If screening or a barrier structure is required, or installed as an optional feature, the clearance limitations of notes 2 and 3 must be maintained. 4. A 3’-0” minimum clearance is to be maintained from pad sides and back, to the nearest structure or plantings. A level graded, 10’-0” minimum clearance is to be maintained from the front of pad, to the nearest fixed structure or plantings. If a full length gate is installed, it shall be hinged and no closer than 3’-0” from pad front. Local government, fire protection, and building codes may require greater clearances. Customer will avoid plantings or construction that interferes with Company’s required maintenance access to its equipment. If a fence or barrier is to be installed, it must be coordinated with the Company. 5. All conduits shall extend 5’-0” beyond the pad and screening structure (if used) and the locations of the ends of primary conduits shall be identified. Primary conduit shall be installed between 42” and 48” below final Secondary conduit shall be installed between 30” and 42” below final grade. 6. When metallic conduit is utilized, customer shall install grounding bushings. 7. When necessary for traffic protection, set a 4” diameter concrete-filled galvanized steel post 3’-0” from pad Post shall be 8’ long with a 4’ concrete embedment. 8. All Company transformers shall be located in mutually agreed upon location with hard surface access and unobstructed work space for large vehicles. If special equipment, such as a crane, is required for setting or replacing the transformer, the customer shall pay all expenses. 9. A trench 2’-0” deep and 3’-0” wide will be dug on all four sides. The trench will be lined with silt fence fabric and filled with 3” screened river rock to final grate. Contact local engineering representative if design needs modification. CRITICAL CROSSINGS: 1.BOTTOM OF STORM = 1015.97 TOP OF WATER = 1013.6 (PER CEC PLANS) 2.TOP OF SANITARY ≈ 1013.95 BOTTOM OF WATER = 1015.8 (PER CEC PLANS) 3.BOTTOM OF STORM = 1015.06 TOP OF STORM = 1016.56 BOTTOM OF WATER = 1018.68 (ASSUMING 5.5' DEPTH - FIELD VERIFY) 4.TOP OF SANITARY ≈ 1008.56 BOTTOM OF STORM ≈ 1014.91 SANITARY SERVICE DETAIL 1015 1015 10 2 0 1020 1016 1016 1017 1017 10 1 8 1018 10 1 9 1019 1 0 2 1 1021 1 0 2 2 1022 1 0 2 2 102 3 1 0 2 3 102 4 10 2 4 1 0 2 0 10 2 5 10 2 5 10 3 0 10 3 0 1 0 2 1 10 2 2 10 2 3 10 2 4 10 2 4 10 2 6 10 2 6 10 2 7 10 2 7 10 2 8 10 2 8 10 2 9 10 2 9 1025 1025 1021 10 2 1 1022 102 2 1023 10 2 3 1024 1024 10 2 4 1024 1026 1026 10 2 5 10 2 2 10 2 3 10 2 4 10 2 6 10 2 7 10 2 8 10 2 9 1025 1022 1023 1024 1026 1027 1027 1 0 2 1 1 0 2 2 10 2 2 1 0 2 2 1 0 2 3 TS Hickman Rd Storm Sewer Rim: 1025.18 Storm Sewer Rim: 1024.55 One Way One Way Yield Stop RESTAURANT 7,307 SQ. FT. FF: 1024.00 COVERED PATIO NW 2 N D S T 10 0 ' R O W ST 6' S I D E W A L K NO C U R B CURB TRANSITION CURB TRANSITION 1025.741025.77 NO T E 1 NO T E 1 NO T E 1 NOTE 1 BREAKLINE (TYP) E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T 6" SUBDRAIN TRASH ENCLOSURE P S T P S T P S T P S T P S T P S T P S T P S T P S T P S T P S T P S T P S T P STP STP ST P ST P ST P S T P S T P S T P S T P S T P S T P STP STP STP ST 100-YEAR PONDING ELEVATION = 1021.86 ST ST E STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE ST 18" STORM15" STORM 18" STORM E ST E ST E ST E ST 15" STORM 1022.16 1023.67 1024.47 1025.20 - 1 . 5 % -1.2% -1 . 5 % -3 . 6 % -3 . 5 % -6.2% -23.5% -9 . 3 % -1 2 . 8 % -27.8% -24.2% -24.7% -2 4 . 0 % -24.0% -20 . 0 % -2 3 . 7 % - 2 3 . 0 % -2 2 . 7 % -25.0% - 4 . 0 % -2 5 . 2 % -2 3 . 0 % -20 . 3 % - 2 . 0 % -2.7 % -4.6% 100-YEAR PONDING ELEVATION = 1021.52 100-YEAR PONDING ELEVATION = 1022.56 1020 1020 1017 1017 1018 1018 1019 1019 1021 1022 1023 1024 E STE STE STE ST INTAKE OVERFLOW ROUTE ELEVATION = 1022.76 INTAKE OVERFLOW ROUTE ELEVATION = 1023.38 INTAKE OVERFLOW ROUTE ELEVATION = 1022.76 1022.76 1022 102 3 1023 102 2 102 2 1 0 2 2 102 3 102 3 1 0 2 3 102 4 1024 10 2 5 1025 1 0 2 2 1 0 2 3 1024 10 2 4 1024 1 0 2 4 10 2 6 1026 102 6 10 2 6 10 2 7 1027 1027 1027 102 7 1 0 2 7 10 2 8 1025 10 2 3 1023 1 0 2 4 1 0 2 4 1 0 2 6 1 0 2 2 1 0 2 3 1022 1023 1021 1022 10 2 3 10 2 4 10 2 4 1023 10 2 4 10 2 5 1025 10 2 3 10 2 4 1025 1024 1022.54G 1022.44G 1022.11G 1022.06G 1021.93G 1022.10G 1021.79G 1021.61G 1021.71G 1021.82G 1022.00G 1023.31G 1023.18G 1023.35G 1023.34G 1023.71G 1023.81G 1021.07G 1022.45GHP 1023.24G 1022.93G 1022.68G 1022.32G HP 1022.76G1023.45G ???G 1022.53GHP 1023.60G 1023.32G 1023.29G 1023.14G 1022.95G 1023.02G 1023.02G 1023.11G HP 1023.38G 1022.86G 1021.50G 1022.33G 1023.43G1023.85G 1024.27G 1024.85G 1024.97G 1024.98G 1025.05G 1025.18G1023.83G 1023.66G 1023.53G1023.43G 1023.56G 1023.73G1023.11G 1022.95G 1022.84G 1022.91G 1023.50G 1023.49G 1023.43G 1023.35G HP 1023.71G 1023.69G 1023.54G 1023.35G 1023.34G1023.33G 1023.30G 1023.26G1023.26G 1022.48G 1022.26G1022.16G 1022.36G 1023.09G1022.55G 1021.97G 1021.51G1021.47G 1021.56G 1021.76G 1022.56G 1022.10G 1023.25G 1023.22G 1023.21G 1023.22G 1023.14G 1023.23G 1023.38G 1023.35G 1023.40G1023.31G 1023.18G 1024.01G 1023.85G 1023.86G 1024.44G 1024.43G 1024.25G1023.20G 1023.20G1023.08G 1022.99G 1022.73G 1022.64G1022.52G 1022.52G 1021.88G 1021.72G 1021.72G 1022.29G 1022.29G 1022.12G LP 1021.80G LP 1022.48G LP 1021.10 1023.46 1023.35G HP 1023.59G 1023.37 1023.29G 1022.74G 1023.14G 1026.40 1022.71 1023.09 1022.63 1022.45 1023.79 1024.00 1024.00 1023.90 1023.22G 1023.30G 1023.34G 1023.39G 1023.05G 1023.11G 1024.00 1024.00 1024.00 1024.00 1024.00 1024.00 1024.00 1024.00 1024.00 1024.00 1024.001024.00 1024.001024.00 1024.06G PROPOSED 4" PCC SIDEWALK CURB RAMP TURNING SPACE NOTES: 1.CONTOURS SHOWN AS EXISTING ARE COMBINED FROM PDS' SURVEY AND FROM THE PRE-PLAT SURFACE PER CEC PLAN DATED 08-15-2022. PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: C-104 - GRADING SHEET 10-04-22 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: B. SHORT J:\2022 Projects\22-001 - Guadalajara Restaurant - Waukee\Engineering\Site Plan\Sheet Set WAUKEE, IOWA GUADALAJARA RESTAURANT 185 W HICKMAN RD TITLE: ----22-0011"=20' PRELIMINARY LEGEND: GUY ANCHOR ELEC. TRANSFORMER ELEC. METER ELEC. BOX ELEC. VAULT GAS METER UTILITY PEDESTAL CABLE TV JUNCTION BOX SIGN PARKING SPACE STREET LIGHT POWER POLE LIGHT POLE MORE OR LESS GUTTER ELEVATION TOP OF CURB ELEVATION +/- EXISTING/ PROPOSED ELEVATION 123.45G 123.45TC FLOWLINE ELEVATIONFL FINISHED FLOORF.F. WATER METER 123.45123.45/ CALCULATED SECTION CORNER FOUND SECTION CORNER CALCULATED CORNER FOUND CORNER AREA LIGHT CONTROL POINT FIBER OPTIC VAULT SINGLE INTAKE WATER VALVE FLARED END SECTION ELEC. MANHOLE GAS VALVE FIBER OPTIC FENCE LINE FIRE HYDRANT SANITARY SEWER MANHOLE WATER GAS LINE SANITARY SEWER STORM SEWER UNDERGROUND TEL. OVERHEAD TEL. W ST UGT OHT CABLE TELEVISIONCATV GAS SS STORM SEWER MANHOLE PROPOSED UTILITY LINEP XX CLEANOUT DOWNSPOUTD UNDERGROUND ELEC.UGE OVERHEAD ELEC.OHE EXISTING UTILITY LINEE XX FO THROAT INTAKE AREA INTAKE TRAFFIC MANHOLE 10 2 0 10 1 8 10 1 9 1 0 2 1 10 2 5 10 2 5 10 3 0 10 3 0 10 2 4 10 2 4 10 2 6 10 2 6 10 2 7 10 2 7 10 2 8 10 2 8 10 2 9 10 2 9 1021 1022 RESTAURANT 7,307 SQ. FT. FF: 1024.00 COVERED PATIO 6' S I D E W A L K TRASH ENCLOSURE STEP CURB TRANSITION NO C U R B CURB TRANSITION -1.4% -7 . 0 % -7 . 0 % -1.5% 0. 0 % 0. 0 % -1.5% -7 . 0 % -6 . 2 % -0.6% -1 . 6 % -0.4% -1 . 9 % -8.0% -8.1% -2 . 0 % -1.5% -1 . 9 % -1.5% -8 . 0 % -1 . 6 % -1 . 6 % -1.5% -1.5% -8 . 0 % -1.5% -1.5% -1.5% -0.7% -1 . 1 % -1.7% -0 . 7 % -1.4% -0.5% -0 . 9 % -0.1% -0 . 6 % -1 . 3 % -1 . 4 % 0.0% 0.1% 0. 9 % -0.7% -0 . 5 % 0.6% 0. 1 % 0.9% -1 . 4 % -1 . 5 % 0.6 % -1.4% 0. 7 % -0.3% -1 . 5 % -1 . 5 % -1 . 5 % -1 . 5 % -1.5% -1.1%-0 . 3 % 1023.87 1023.76 1023.70 1023.831023.43 1023.29 1023.34 1023.20 1022.331022.24 1022.251022.16 1023.851023.95 1023.89G 1023.52G 1023.50G1023.84G 1023.851023.90 1023.911023.871023.81 1023.90 1023.90 1023.811023.84 1023.901023.90 1023.861023.65 1023.76 1023.801023.70 1023.75 1023.76 1023.63 1023.361023.46 1023.46 1023.46 1023.361023.46 1023.82 1023.86 1023.821023.761023.11 1023.181023.06 1023.01 -1 . 4 % -1 . 9 % 0.0% -1 . 9 % -1 . 5 % 0.0% -1 . 5 % 1024.001024.00 1024.00 1024.001024.001024.001024.00 -1 . 9 % 1024.00 -0 . 8 % -1 . 1 % 0.0% -0.5% 1023.97 1023.95 1023.87 1023.87 102 2 102 3 PROPOSED 4" PCC SIDEWALK CURB RAMP TURNING SPACE 1023 1024 1025.741025.77 10 2 6 -1.5% -1.7% -0.4% -0.4% -5 . 0 % -5 . 0 % -1 . 5 % -1 . 5 % -4 . 5 % -1 . 5 % -1 . 3 % -5 . 1 % -1.5% -0.5% 1023.601023.50 1024.59 1024.66 1024.61 1024.69 1024 10 2 4 1024 10 2 2 E S T E S T E S T E S T 1022.16 -5.3% DETECTABLE WARNING MIN 2' WIDTH DETECTABLE WARNING MIN 2' WIDTH - 2 . 0 % -2 . 9 % -0.5% -1.3% - 1 . 5 % - 1 . 5 % - 0 . 6 % - 0 . 9 % -1.0% -1.5% - 0 . 5 % - 0 . 5 % -2.2% -1.5% 1022.37 1022.52 1022.25 1022.35 1022.491022.64 1022.35 1022.48 1022.131022.19 1 0 2 2 1 0 2 3 1025 10 2 3 10 2 4 E S T E S T E S T E S T E S T E S T E S T E S T E S T DETECTABLE WARNING MIN 2' WIDTH DETECTABLE WARNING MIN 2' WIDTH -0.7% 0. 4 % 1. 0 % -0.2% 0. 8 % 0. 1 % -1.0% -1.7% -1 . 5 % -1 . 8 % -1.4% 1022.491022.55 1022.36 1022.53 1022.90 1022.99 1023.051023.07 10 2 5 1 0 2 2 1 0 2 3 1 0 2 4 10 2 3 1025 1024 PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: C-105 - GRADING DETAIL SHEET 10-04-22 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: B. SHORT J:\2022 Projects\22-001 - Guadalajara Restaurant - Waukee\Engineering\Site Plan\Sheet Set WAUKEE, IOWA GUADALAJARA RESTAURANT 185 W HICKMAN RD TITLE: ----22-0011"=20' PRELIMINARY SOUTH SIDEWALK CONNECTION SLOPES NORTH ENTRANCE SIDEWALK SLOPES SOUTH ENTRANCE SIDEWALK SLOPES MAIN SITE SIDEWALK SLOPES 1015 1015 10 2 0 1020 1016 1016 1017 1017 10 1 8 1018 10 1 9 1019 1 0 2 1 1021 1 0 2 2 1022 1 0 2 2 102 3 1 0 2 3 102 4 10 2 4 1 0 2 0 10 2 5 10 2 5 10 3 0 10 3 0 1 0 2 1 10 2 2 10 2 3 10 2 4 10 2 4 10 2 6 10 2 6 10 2 7 10 2 7 10 2 8 10 2 8 10 2 9 10 2 9 1025 1025 1021 1022 1023 1024 1026 1026 10 2 5 10 2 2 10 2 3 10 2 4 10 2 6 10 2 7 10 2 8 1025 1026 1027 1027 1 0 2 2 10 2 2 1 0 2 2 1 0 2 3 TS RESTAURANT 7,307 SQ. FT. FF: 1024.00 COVERED PATIO NW 2 N D S T 10 0 ' R O W ST 1025.741025.77 E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T TRASH ENCLOSURE P S T P S T P S T P S T P S T P S T P S T P S T P S T P S T P S T P S T P S T P STP STP ST P ST P ST P S T P S T P S T P S T P S T P S T P STP STP STP ST E ST E ST 1022.16 1023.67 1024.47 1025.20 1020 1018 1019 1021 1022 1023 1024 E STE STE ST 1022.76 1022 102 3 1023 102 2 10 2 2 1 0 2 2 102 3 102 3 1 0 2 3 102 4 1024 10 2 5 1025 1 0 2 2 1 0 2 3 1024 10 2 4 1024 1 0 2 4 10 2 6 1026 102 6 10 2 6 10 2 7 1027 1027 1027 102 7 10 2 7 10 2 8 1025 10 2 3 1023 1 0 2 4 1 0 2 4 1 0 2 6 1 0 2 2 1 0 2 3 1022 1023 1021 1022 10 2 3 10 2 4 10 2 4 1023 10 2 4 10 2 5 1025 10 2 3 10 2 4 1025 1024 LIMITS OF DISTURBANCE AREA: 2 AC ULTIMATE DISCHARGE NEAREST WATERBODY: LITTLE WALNUT CREEK INSTALL ADS FLEXSTORM LITE OR APPROVED EQUAL INSTALL ADS FLEXSTORM LITE OR APPROVED EQUAL INSTALL ADS FLEXSTORM LITE OR APPROVED EQUAL FILTER SOCK SWPPP NOTES: 1.LOCATION OF STAGING AREAS TO CONTAIN: JOB TRAILERS, FUELING LOCATION, TEMPORARY SANITARY FACILITIES, MATERIALS STORAGE, CONCRETE WASHOUT AREA. CONTROL RUNOFF WITH DIVERSION BERMS OR SILT FENCE AND DIRECT TO SEDIMENT BASIN WHERE POSSIBLE. 2.ALL INTERIOR & PERIMETER SILT FENCE NOT SHOWN. SEE EROSION CONTROL PLAN. 3.MULCH OR SOD ALL DISTURBED AREAS NOT PAVED OR DEVELOPED. 4.ADDITIONAL CONTROLS MAY BE REQUIRED DEPENDING ON PHASING & SITE CONDITIONS. CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING, NOTING & IMPLEMENTING. 5.A MINIMUM 8" LAYER OF TOPSOIL SHALL BE RESPREAD FROM THE STOCKPILE ONSITE TO SODDED PERVIOUS SURFACES THAT WERE DISTURBED DURING CONSTRUCTION. 6.ALL BARE AREAS THAT WILL REMAIN INACTIVE FOR 14 DAYS OR MORE REQUIRE IMMEDIATE STABILIZATION MEASURES (SUDAS TYPE 4 SEED MIXTURE - SEE BELOW. QUANTITY UP TO 100 LB RYEGRASS, 190 LB OATS.) 7.ALL SLOPES 4:1 OR GREATER REQUIRE SEEDING AND MATTING 8.CONTOURS SHOWN AS EXISTING ARE COMBINED FROM PDS' SURVEY AND FROM THE PRE-PLAT SURFACE PER CEC PLAN DATED 08-15-2022. 9.STORM SEWERS AND DRAINAGE WAYS SHALL BE PROTECTED FROM CONCRETE SLURRY PRODUCED BY SAWCUTTING AND GRINDING. PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: C-106 - EROSION & SEDIMENT CONTROL SHEET 10-04-22 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: B. SHORT J:\2022 Projects\22-001 - Guadalajara Restaurant - Waukee\Engineering\Site Plan\Sheet Set WAUKEE, IOWA GUADALAJARA RESTAURANT 185 W HICKMAN RD TITLE: ----22-0011"=20' PRELIMINARY LEGEND: GUY ANCHOR ELEC. TRANSFORMER ELEC. METER ELEC. BOX ELEC. VAULT GAS METER UTILITY PEDESTAL CABLE TV JUNCTION BOX SIGN PARKING SPACE STREET LIGHT POWER POLE LIGHT POLE MORE OR LESS GUTTER ELEVATION TOP OF CURB ELEVATION +/- EXISTING/ PROPOSED ELEVATION 123.45G 123.45TC FLOWLINE ELEVATIONFL FINISHED FLOORF.F. WATER METER 123.45123.45/ CALCULATED SECTION CORNER FOUND SECTION CORNER CALCULATED CORNER FOUND CORNER AREA LIGHT CONTROL POINT FIBER OPTIC VAULT SINGLE INTAKE WATER VALVE FLARED END SECTION ELEC. MANHOLE GAS VALVE FIBER OPTIC FENCE LINE FIRE HYDRANT SANITARY SEWER MANHOLE WATER GAS LINE SANITARY SEWER STORM SEWER UNDERGROUND TEL. OVERHEAD TEL. W ST UGT OHT CABLE TELEVISIONCATV GAS SS STORM SEWER MANHOLE PROPOSED UTILITY LINEP XX CLEANOUT DOWNSPOUTD UNDERGROUND ELEC.UGE OVERHEAD ELEC.OHE EXISTING UTILITY LINEE XX FO THROAT INTAKE AREA INTAKE TRAFFIC MANHOLE QUANTITIES ITEM QTY UNITS FILTER SOCK 528 LF INLET PROTECTION 4 EA CONSTRUCTION ENTRANCE 1 LS CONCRETE WASHOUT 1 LS SOD 28,144 SF SUDAS TYPE 4 SEED MIXTURE 2.05 AC 2. STABILIZED CONSTRUCTION ENTRANCE REVISION NO. REVISION DATE 10/17/06 FIGURE: 9040.120 Le n g t h STABILIZED CONSTRUCTION SHEET 1 OF 1 1. 2. 3. 4. 5. 1 2 Width 10' m i n . Remove vegetation and excavate soft soils from entrance area. Thoroughly compact subgrade prior to placing stone. Install culvert under entrance if necessary to maintain drainage. Grade entrance to prevent runoff from flowing onto street. Direct all runoff from entrance to a sediment retention device. When specified, install subgrade stabilization fabric prior to placing crushed stone. Install layer of crushed stone to the thickness (6 in. min.) and dimensions specified. Thickness as specified (6" min.) 1 1 1 2 --- Entrance length: 50 ft. minimum (30 ft. for single family residential), or as specified. Length of entrance may be increased if sediment track-out occurs. Entrance width: 20 ft. minimum. ENTRANCE 12 " 24 " 2'-0" 10 ' - 0 " m a x . Berm shown is typical for slopes flatter than 3:1. For steeper slopes, increase berm size as directed by the Engineer. Place berm in uncompacted windrow perpendicular to the slope at locations specified in the contract documents. Filter sock diameter as specified in the contract documents. 20 0 ' - 0 " m a x . l e n g t h p e r s e c t i o n 3' m i n . Ove r l a p 9040-102 FILTER BERM AND FILTER SOCK TSE Hickman Rd FOVStorm Sewer Rim: 1025.18 Storm Sewer Rim: 1024.55 One Way One Way Yield Stop 16.5' TELECOMMUNICATIONS EASEMENT - APPROXIMATE LOCATION (BK 709 PG 455) RESTAURANT 7,307 SQ. FT. FF: 1024.00 COVERED PATIO 10' PUE 10 ' P U E NW 2 N D S T 10 0 ' R O W LUMEN E U G E E U G E E U G E E UGE E UGE E UGE E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO E FO 10' PUE 10' GAS MAIN EASEMENT 10 ' P U E PUBLIC STORM SEWER EASEMENT BK 2020 PG 1343 10' PUE ST 20' PRIVATE WATER MAIN EASEMENT BK 2020 PG 1346 20' STORM SEWER EASEMENT E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E OHE E U G E E U G E E U G E E U G E E U G E E U G E E U G E E U G E E U G E E U G E E U G E E U G E E GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GASE GAS E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T 6" SUBDRAIN T Y P E A D R I V E W A Y TY P E A D R I V E W A Y PE R M A N E N T R I G H T - I N / R I G H T - O U T M I N . 6 " P C C ( T Y P ) TRASH ENCLOSURE P S T P S T P S T P S T P S T P S T P S T P S T P S T P S T P S T P S T P S T P STP STP ST P ST P ST P S T P S T P S T P S T P S T P S T P STP STP STP ST ST ST E STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE STE ST 18" STORM15" STORM 18" STORM E ST E ST E ST E ST 15" STORM E GAS E GAS E GAS E GAS E GAS E GAS E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S PRIVATE MONUMENT SIGN EASEMENT (BK 2020 PG 1349) PUBLIC SANITARY SEWER EASEMENT BK 2020 PG 1340 4" GAS 1" G A S P GAS P GAS P GAS P GAS P GAS P GAS E STE STE STE ST 20' STORM SEWER EASEMENT PUBLIC SANITARY SEWER EASEMENT BK 2020 PG 1340 PROPOSED PRIVATE SEWER EASEMENT PUBLIC WATER MAIN EASEMENT BK 2020 PG 1346 LIMITS OF DISTURBANCE SOD OFFSITE DISTURBED AREAS SOD OFFSITE DISTURBED AREAS SO D O F F S I T E D I S T U R B E D A R E A S SO D O F F S I T E D I S T U R B E D A R E A S PROPOSED TREES: SYMBOL #COMMON NAME MIN. PLANTING SIZE MATURE SIZE (BOTANICAL NAME)(HEIGHT & SPREAD) 3 TULIP TREE 2" CALIPER B&B 70-90' & 35-50' (LIRIODENDRON TLIPFERA)8' TALL 4 KENTUCKY COFFEETREE 2" CALIPER B&B 60-75' & 40-50' (GYMNOCLADUS DIOICA 'ESPRESSO') 8' TALL 3 AMERICAN LINDEN 2" CALIPER B&B 60-80' & 20-40' (TILIA AMERICANA) 8' TALL 5 AMERICAN HOPHORNBEAM 2" CALIPER B&B 25-40' & 20'-40' (OSTRYA VIRGINIANA)6' TALL 2 EASTERN REDBUD 2" CALIPER B&B 20-30' & 25-35' (CERCIS CANADENSIS)6' TALL 1 LOEBNER MAGNOLIA 2" CALIPER B&B 20-30' & 20-30' (MAGNOLIA x LOEBNERI)6' TALL LANDSCAPING REQUIREMENTS: MINIMUM QUANTITIES 1 TREE/1,000 SF REQUIRED OPEN SPACE =70,185*0.2/1000= 14 TREES PARKING LOT BUFFER 1 OVERSTORY DECIDUOUS TREE/40 LF FRONTAGE EAST = 195 LF FRONTAGE; SOUTH = 211 LF 406 LF/40 ≈ 10 TREES PARKING LOT INTERIOR 1 TREE/ INTERIOR ISLAND = 6 TREES MIN. 3 SHADE TREES TOTAL TREES REQUIRED: 14 TOTAL TREES PROVIDED: 19 MINIMUM NUMBER OF SHADE TREES: 10 SHADE TREES PROVIDED: 15 PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: C-107 - LANDSCAPING SHEET 10-04-22 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: B. SHORT J:\2022 Projects\22-001 - Guadalajara Restaurant - Waukee\Engineering\Site Plan\Sheet Set WAUKEE, IOWA GUADALAJARA RESTAURANT 185 W HICKMAN RD TITLE: ----22-0011"=20' PRELIMINARY LEGEND: GUY ANCHOR ELEC. TRANSFORMER ELEC. METER ELEC. BOX ELEC. VAULT GAS METER UTILITY PEDESTAL CABLE TV JUNCTION BOX SIGN PARKING SPACE STREET LIGHT POWER POLE LIGHT POLE MORE OR LESS GUTTER ELEVATION TOP OF CURB ELEVATION +/- EXISTING/ PROPOSED ELEVATION 123.45G 123.45TC FLOWLINE ELEVATIONFL FINISHED FLOORF.F. WATER METER 123.45123.45/ CALCULATED SECTION CORNER FOUND SECTION CORNER CALCULATED CORNER FOUND CORNER AREA LIGHT CONTROL POINT FIBER OPTIC VAULT SINGLE INTAKE WATER VALVE FLARED END SECTION ELEC. MANHOLE GAS VALVE FIBER OPTIC FENCE LINE FIRE HYDRANT SANITARY SEWER MANHOLE WATER GAS LINE SANITARY SEWER STORM SEWER UNDERGROUND TEL. OVERHEAD TEL. W ST UGT OHT CABLE TELEVISIONCATV GAS SS STORM SEWER MANHOLE PROPOSED UTILITY LINEP XX CLEANOUT DOWNSPOUTD UNDERGROUND ELEC.UGE OVERHEAD ELEC.OHE EXISTING UTILITY LINEE XX FO THROAT INTAKE AREA INTAKE TRAFFIC MANHOLE PROPOSED SHRUBS: SYMBOL #COMMON NAME MIN. PLANTING SIZE MATURE SIZE (BOTANICAL NAME)(HEIGHT & SPREAD) 18 SUNRISE FORSYTHIA 4-5' & 4-5' (FORSYTHIA 'SUNRISE') 35 DOUBLE PLAY GOLD SPIREA 2' & 2' (SPIRAEA JAPONICA 'YAN') 10 GOLDEN SUNRISE SPIREA 3-4' & 3-4' (SPIRAEA x BUMALDA 'MONHUD') 36 KARL FOERSTER GRASS 36-60" & 24-36" (CALAMAGROSTIS ACUTIFLORA) TOTAL 99 SHRUBS/GRASSES FLOOR PLAN -LEVEL 1 EL ( 0" ) LOWER TRUSS BEARING EL ( 13'-0" ) TRUSS BEARING EL ( 22'-6" ) UNA CLAD STANDING SEAM METAL SIDING TYP. 2" WEATHERED EDGE CLAD STONE TYP. UNA CLAD METAL FLASHING PARAPET CAP TYP. STONE WAINSCOT TYP. UNA CLAD METAL FASCIA TYP. UNA CLAD STANDING SEAM METAL ROOFING TYP. TUBELITE CALVANIZED HOLLOW METAL FRAME TYP. TREATED 6X6 COLUMN CLADED W/ SMOOTH SURFACE BLACK STEEL RAILINGS GATE FIRE DEPARTMENT CONNECTION FLOOR PLAN -LEVEL 1 EL ( 0" ) LOWER TRUSS BEARING EL ( 13'-0" ) TRUSS BEARING EL ( 22'-6" ) UNA CLAD STANDING SEAM METAL SIDING TYP. 2" WEATHERED EDGE CLAD STONE TYP. UNA CLAD METAL FLASHING PARAPET CAP TYP. 2X6 SMOOTH TRIM TYP. STONE WAINSCOT TYP. UNA CLAD METAL FASCIA TYP.1/2" 1'-0" 1" 1'-0" UNA CLAD STANDING SEAM METAL ROOFING TYP. 4' - 8 " GAS SERVICE FLOOR PLAN -LEVEL 1 EL ( 0" ) LOWER TRUSS BEARING EL ( 13'-0" ) TRUSS BEARING EL ( 22'-6" ) 1/2" 1'-0" 1" 1'-0" UNA CLAD STANDING SEAM METAL SIDING TYP. 2" WEATHERED EDGE CLAD STONE TYP.UNA CLAD METAL FLASHING PARAPET CAP TYP. STONE WAINSCOT TYP. 2X10 SMOOTH TRIM TYP. UNA CLAD METAL FASCIA TYP. UNA CLAD STANDING SEAM METAL ROOFING TYP. TUBELITE CALVANIZED HOLLOW METAL FRAME TYP. TREATED 6X6 COLUMN CLADED W/ SMOOTH SURFACE BLACK STEEL RAILINGS 4' - 8 " ADDRESS NUMBERS GATE FLOOR PLAN -LEVEL 1 EL ( 0" ) LOWER TRUSS BEARING EL ( 13'-0" ) TRUSS BEARING EL ( 22'-6" ) UNA CLAD STANDING SEAM METAL SIDING TYP. 2" WEATHERED EDGE CLAD STONE TYP. UNA CLAD METAL FLASHING PARAPET CAP TYP. STONE WAINSCOT TYP. UNA CLAD METAL FASCIA TYP. UNA CLAD STANDING SEAM METAL ROOFING TYP. TUBELITE CALVANIZED HOLLOW METAL FRAME TYP. 4' - 8 " REVISION P 2323 Dixon Street, Des Moines, Iowa 50316 P.O. Box 4626 Des Moines, Iowa 50305 P: 515-265-8196 www.pelds.com PR O J E C T N A M E : SHEET NUMBER: SHEET TITLE: JOB NUMBER:DRAWN BY: DATE OF ISSUE: pelds Design Services Architecture | Engineering | Surveying KEY PLAN ARCHITECT: CHECKED BY: 9/ 2 2 / 2 0 2 2 1 1 : 3 0 : 5 2 A M A200 Author 09.02.2022 Project Number ELEVATIONS WA U K E E , I O W A SCHEMATIC DESIGN GU A D A L A J A R A RE S T A U R A N T Checker No DESC DATE 1/8" = 1'-0"1 EAST BUILDING ELEVATION 1/8" = 1'-0"2 NORTH BUILDING ELEVATION 1/8" = 1'-0"3 SOUTH BUILDING ELEVATION 1/8" = 1'-0"4 WEST BUILDING ELEVATION MATERIAL CLASSIFICATION VERTICAL SIDING SECONDARY 24%16%21%25% DOORS -3%3%3%0% GLASS PRIMARY 0%9%15%21% STONE PRIMARY 73%68%59%54% ALUMINUM PANELS PRIMARY 0%4%2%0 MATERIAL OVERLAY CLASS EAST FACADE%SOUTH FACADE%NORTH FACADE%WEST FACADE%