Loading...
HomeMy WebLinkAbout2022-10-17 I15A-C James Pointe Plat 3 Lot 1_Preliminary Plat, Final Plat, Site PlanAGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: October 17, 2022 AGENDA ITEM:Consideration of approval of resolutions approving a preliminary plat, final plat and site plan for James Pointe Plat 3 Lot 1 FORMAT:Resolution SYNOPSIS INCLUDING PRO & CON: The applicant is requesting approval of a preliminary plat, final plat and site plan for a 2.61-acre development for a warehouse / storage facility development located north of Hickman Road and east of NW 17th Street. The project involves the construction of two buildings to be used as “toy- plex” style storage facilities. One building will be 22,500-square feet and have 15-units and the second building will be 24,300-square feet and have 20-units. The elevations of the buildings will be constructed of Nichiha engineered stone panels and architectural metal paneling in shades of gray. No trash enclosures or monument signs are proposed. The final plat includes two lots combined into one lot that is 2.61-acres in area. No new easements are proposed. All easements were recorded with the James Pointe Plat 1 Final Plat. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning Commission reviewed the site plan request at their meeting on September 27, 2022 and recommended approval: Approval of a Preliminary Plat for James Pointe Plat 3 Lot 1 Approval of a Final Plat for James Pointe Plat 3 Lot 1 Approval of a Site Plan for James Pointe Plat 3 Lot 1 City Planner, Bill Mettee, provided an outline of the project, as shown in the staff report. The applicant, Back Nine Properties, LLC, is requesting approval of a preliminary plat, final plat and site plan for a warehouse / storage facility north of NW Gettysburg Lane and east of NW 17th Street, containing 2.61-acres. Mr. Mettee explained that the project included the construction of two buildings to be used as “toy- plex” style buildings to be used as storage for boats, RVs and similar items. One building will be 22,500-square feet and have 15-units and one building will be 24,300-square feet and includes 20- units. No trash enclosures or monument signs are proposed. Mr. Mettee explained that two access points were provided that align with the 2021 James Pointe Plat 2 project to the south. Three parking spaces are required and have been provided with one being an I15A-C accessible space. All utilities exist in the immediate vicinity and will be extended to service this project. Storm water detention will be provided with one of the regional ponds nearby. The applicant is providing 32.23% open space which includes a 40-foot landscape buffer along the north property line. The landscape buffer includes 90-trees, which meets the ordinance requirements. Building elevations were submitted for review and include Nichiha engineered stone panels and architectural metal paneling in shades of gray. Transom windows and variations in building offsets have been incorporated to break up the rear building walls. Mr. Mettee explained that the final plat was due to the fact that two lots were being combined into one lot for the purposes of this project. Lot 1 is 113,949-square feet and is zoned M-1 Light Industrial and this project is consistent with the zoning. Mr. Mettee stated that staff recommended approval of the preliminary plat, final plat and site plan subject to remaining staff comments and review of the legal documents. Motion was made by Alex Broderick to approve the Preliminary Plat as presented. The motion was seconded by Kullen Koelker. On voice vote: All ayes: Motion carries 5-0. Motion was made by Luke Streit to approve the Final Plat as presented. The motion was seconded by Kullen Koelker. On voice vote: All ayes: Motion carries 5-0. Motion was made by Luke Streit to approve the Site Plan. The motion was seconded by Kullen Koelker. On voice vote: All ayes: Motion carries 5-0 STAFF REVIEW AND COMMENT: Staff recommends approval of the preliminary plat, final plat and site plan subject to remaining staff comments and review of the legal documents. RECOMMENDATION: Approve the resolutions. ATTACHMENTS: I. Proposed Resolutions II. Staff Report III. Preliminary Plat / Site Plat IV. Final Plat V. Building Elevations PREPARED BY:Bill Mettee, Planner REVIEWED BY: PUBLIC NOTICE INFORMATION – NAME OF PUBLICATION: DATE OF PUBLICATION: THE CITY OF WAUKEE, IOWA RESOLUTION 2022- APPROVING THE PRELIMINARY PLAT FOR JAMES POINTE PLAT 3 LOT 1 IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission reviewed and recommended approval of a Preliminary Plat for James Pointe Plat 3 Lot 1 on September 27, 2022; AND, WHEREAS, the Preliminary Plat for James Pointe Plat 3 Lot 1 is in general conformance with section §176 - Subdivision Regulations of the Waukee Municipal Code. NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this the 17th day of October, 2022 that the Preliminary Plat for James Pointe Plat 3 Lot 1 be approved subject to remaining staff comments. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Anna Bergman Pierce R. Charles Bottenberg Chris Crone Larry R. Lyon Ben Sinclair THE CITY OF WAUKEE, IOWA RESOLUTION 2022- APPROVING THE FINAL PLAT FOR JAMES POINTE PLAT 3 LOT 1 IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, Back Nine Properties, LLC, has requested final plat approval of James Pointe Plat 3 Lot 1 (the “Plat”); AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Plat on September 27, 2022, subject to remaining staff comments and review of the legal documents; AND, WHEREAS, the Final Plat for James Pointe Plat 3 Lot 1 and the documents relating thereto will comply with section §176 – Subdivision Regulations of the Waukee Municipal Code. NOW, THEREFORE, BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 17th day of October, 2022, that the Final Plat for James Pointe Plat 3 Lot 1 be and the same is hereby accepted and approved by the City Council of the City of Waukee. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Anna Bergman Pierce R. Charles Bottenberg Chris Crone Larry R. Lyon Ben Sinclair THE CITY OF WAUKEE, IOWA RESOLUTION 2022- APPROVING THE SITE PLAN FOR JAMES POINTE PLAT 3 LOT 1 IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Site Plan for James Pointe Plat 3 Lot 1, subject to remaining staff comments on September 27, 2022; AND, WHEREAS, the Site Plan for James Pointe Plat 3 Lot 1 is in general conformance with §160 – Site and Building Development Standards Ordinance of the Waukee Municipal Code; AND, WHEREAS, the Site Plan for James Pointe Plat 3 Lot 1 is in general conformance with §161 – Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND, NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 17th day of October, 2022 that the Site Plan for James Pointe Plat 3 Lot 1 is approved subject to remaining staff comments. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Anna Bergman Pierce R. Charles Bottenberg Chris Crone Larry R. Lyon Ben Sinclair PLANNING AND ZONING COMMISSION STAFF REPORT PROJECT: James Pointe Plat 3 Lot 1 – Preliminary Plat, Site Plan and Final Plat PREPARED BY: Bill Mettee – Planner REPORT DATE: September 23, 2022 MEETING DATE: September 27, 2022 GENERAL INFORMATION Applicant / Owner: Back Nine Properties, LLC Engineer: Michael Wahlert, Orca Consulting Request: The applicant is requesting approval of a preliminary plat, final plat and site plan for a warehouse / storage facility. Location and Size: Property is located north of NW Gettysburg Lane and east of NW 17th Street, containing approximately 2.61-acres. Property Address: 1575 NW Gettysburg Lane AREA MAP ABOVE: Aerial of subject property (outlined in RED) in relation to the surrounding area. September 23, 2022 2 of 3 LAND USES AND ZONING Location Existing Land Use Comprehensive Plan Current Zoning Property in Question Vacant – Undeveloped Mixed Use M-1 (Light Industrial District) North Redwood Townhomes Medium-Density Residential R-4 (Row Home and Townhome Dwelling District) South Warehouse / Office Mixed Use M-1 (Light Industrial District) East Vacant - Undeveloped Mixed Use M-1 (Light Industrial District) West Vacant - Undeveloped Mixed Use M-1 (Light Industrial District) PROJECT DESCRIPTION The site plan identifies the construction of two buildings to be used as a “toy-plex” style storage facilities. Building 1 is proposed to be 22,500 square feet and Building 2 is proposed to be 24,300 square feet. Each building will face the interior of the lot. Building 1 will have 15 units and Building 2 will have 20 units. The buildings will be 20-feet in height. No monument signs or trash enclosures are proposed. Table 1 below summarizes the bulk regulations that are applicable to the proposed development. The site plan demonstrates compliance with the bulk regulations. Table 1: Bulk Regulations for the M-1 District Category M-1 (minimum) Front Yard Setback 30 feet Rear Yard Setback 30 feet, unless the rear lot line adjoins a railroad right-of- way, in which case, none required. Side Yard Setback None required except when adjacent to R or C-1 Districts or street right-of-way line, a side yard of 40-feet shall be required. Maximum Height | Stories 40-feet and 3-stories ACCESS AND PARKING Two access drives are provided to the site off of NW Gettysburg Lane. These drives align with the access drives across NW Gettysburg Lane to the south. A total of three parking spaces are required for this project. The total amount of parking proposed is three spaces, including one required accessible space. The proposed site plan meets the parking requirements. SIDEWALKS/TRAILS A 5-foot-wide sidewalk will be constructed on the north side of NW Gettysburg Lane. UTILITIES The site will be serviced with all public utilities, which are installed in the immediate vicinity of NW Gettysburg Lane. Stormwater detention will be provided with the regional detention basins in the vicinity. September 23, 2022 3 of 3 LANDSCAPING & OPEN SPACE A minimum of 15% of the project area is required to be open space. The total amount of open space proposed is 32.23%. The plantings shown on the landscape plan meet the minimum requirements of the Landscape & Open Space Ordinance. A 40-foot landscape buffer is required along the north property line with a total of 90 trees provided. ELEVATIONS Colored building elevations are included for review. The building is proposed to be constructed predominantly of Nichiha engineered stone panels and architectural metal paneling in shades of gray. Transom windows and variations in building offsets have been added to enhance the rear elevations. LOTS The preliminary plat and final plat identify two lots (Lots 24 and 25). These are two existing lots being combined into one lot. The size of Lot 1 is 113,949-square feet and 2.61 acres in size. The lot is zoned M-1 Light Industrial and comprehensively meets the minimum requirements of the Zoning Ordinance. STAFF RECOMMENDATION The site plan is in general conformance with the Zoning Ordinance, Subdivision Ordinance, Site Plan Ordinance, and Comprehensive Plan. Staff recommends approval of the preliminary plat, final plat, and site plan subject to remaining staff comments and review of the legal documents. SITE PRELIMINARY PLAT/SITE PLAN LOT 1, JAMES POINTE PLAT 3 IOWAONE CALL 1-800-292-8989 www.iowaonecall.com 811 Know what's below. Call before you dig. PROPERTY DESCRIPTION: LOTS 24 & 25, IN JAMES POINTE PLAT 1, AN OFFICIAL PLAT, NOW INCLUDED IN AND FORMING A PART OF THE CITY OF WAUKEE, DALLAS COUNTY, IOWA. SUBJECT TO AND TOGETHER WITH ANY AND ALL EASEMENTS AND RESTRICTIONS OF RECORD. ADDRESS: 1575 NW GETTYSBURG LANE WAUKEE, IOWA 50263 OWNER: BACK NINE PROPERTIES LLC. STACY LYMAN 23033 K AVENUE GRUNDY CENTER, IOWA 50638 (319)231-2995 dslyman@me.com PREPARED FOR: BACK NINE PROPERTIES LLC. GENERAL CONTRACTOR: REFINED CONSTRUCTION SERVICES 2202 WOODLAND PARKWAY CLIVE, IOWA 50325 KEVIN JAKOBE Kevin@rcsiowa.com (515)225-1647 ARCHITECT: PELLA BUILDING SYSTEMS, INC. WIEBE GOODYK 906 WEST 9TH STREET PELLA, IOWA 50219 (800)225-0491 ZONING: M-1 LIGHT INDUSTRIAL BULK REGULATIONS: SETBACKS: FRONT=30' SIDE =0' (ABUTTING LIKE ZONING) REAR = 30' MAXIMUM ALLOWABLE BUILDING HEIGHT = 40' AND 3-STORIES FOR OFFICIAL ZONING CALL CITY OF WAUKEE AT (515) 978-9533 PARKING REQUIREMENTS: SELF-STORAGE SPACES REQUIRED = 1 SP / 20,000GFA PARKING REQUIRED = 46,800 / 20,000 = 3 SP (1 ADA) PARKING PROVIDED = 3 SPACES (1 ADA) OPEN SPACE REQUIREMENTS: OPEN SPACE REQUIRED = 15% OF 113,949.87 SF = 17,092.48 SF OPEN SPACE PROVIDED = 36,729.34 SF = 32.23% IMPERVIOUS SURFACE: 77,220.53 SF IMPERVIOUS OR 67.77% BENCHMARK: SEE C0.1 SITE SURVEY FOR ALL BENCHMARK AND OTHER SPACIAL DATUM INFORMATION VICINITY MAP SCALE: NONE COPYRIGHT 2022 ORCA CONSULTING LLC.. THIS DOCUMENT AND THE INFORMATION CONTAINED MAY NOT BE REPRODUCED OR EXCERPTED WITHOUT THE EXPRESS WRITTEN PERMISSION OF ORCA CONSULTING LLC. UNAUTHORIZED COPYING OR DISCLOSURE OF CONSTRUCTION USE ARE PROHIBITED BY COPYRIGHT LAW. CO V E R S H E E T C0.0 SHEET INDEX C0.0 COVER SHEET C0.1 SITE SURVEY C1.1 DEMO PLAN C2.1 LAYOUT C3.1, 3.2 GRADING PLANS C4.1 UTILITY PLAN C5.1 LANDSCAPE PLAN C6.1, 6.2 DETAILS SHEETS C7.1 SWPPP WETLAND NOTES: 1.ORCA CONSULTING DOES NOT PERFORM WETLAND STUDIES OR WETLAND MITIGATION. IT IS THE OWNER'S RESPONSIBILITY TO DETERMINE IF ANY WETLANDS ARE LOCATED ON THE PROJECT SITE AND PERFORM ANY NECESSARY MITIGATION PRIOR TO THE COMMENCEMENT OF CONSTRUCTION ACTIVITIES. SURVEY NOTES: 1.SURVEY WORK WAS COMPLETED BY BISHOP ENGINEERING ON 5-17-2022. SEE SITE SURVEY PROVIDED AS PART OF THIS SET OF PLANS FOR EXISTING SITE CONDITIONS AND BOUNDARY INFORMATION. SOILS REPORT: 1.A GEOTECHNICAL SOILS REPORT IS THE RESPONSIBILITY OF THE OWNER TO OBTAIN AND PROVIDE TO ORCA CONSULTING FOR CONSIDERATION ON PROPOSED DESIGN. 2.ALL RECOMMENDATIONS WITHIN SOILS REPORT ARE TO BE CONSIDERED THE MINIMUM DESIGN CONSIDERATIONS UNLESS SPECIFICALLY NOTED ON THE PLANS. GENERAL NOTES: 1.ALL WORK SHALL BE DONE IN ACCORDANCE WITH 2020 WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVMENTS AND 2022 SUDAS STANDARD SPECIFICATIONS AND ANY AND ALL CITY/COUNTY SUPPLEMENTAL SPECIFICATIONS. THE CITY OF WAUKEE, IOWA MUST BE NOTIFIED BY ALL CONTRACTORS 48 HOURS PRIOR TO COMMENCING WORK. 2.IN EVENT OF A DISCREPANCY BETWEEN THE QUANTITY ESTIMATES AND THE DETAILED PLANS, THE DETAILED PLANS SHALL GOVERN. 3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION OF ALL UTILITIES. ANY DAMAGE TO SAID UTILITIES SHALL BE REPAIRED AT THE CONTRACTORS EXPENSE. 4.ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE CURRENT O.S.H.A. CODES AND STANDARDS. NOTHING INDICATED ON THESE PLANS SHALL RELIEVE THE CONTRACTOR FROM COMPLYING WITH THE APPROPRIATE SAFETY REGULATIONS. 5.ALL NECESSARY CONSTRUCTION SIGNS, BARRICADES AND OTHER TRAFFIC CONTROL DEVICES REQUIRED DURING CONSTRUCTION WILL BE FURNISHED BY THE CONTRACTOR. SIGNS, BARRICADES AND OTHER TRAFFIC CONTROL DEVICES MUST BE IN CONFORMANCE WITH THE M.U.T.C.D - "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS." 6.ORCA CONSULTING SHALL NOT BE LIABLE FOR ANY INJURIES THAT HAPPEN ON SITE. THIS SHALL INCLUDE BUT NOT BE LIMITED TO TRENCH COLLAPSES FROM VARYING SOIL CONDITIONS OR INJURIES CAUSED BY UNDERGROUND UTILITIES INCLUDING UTILITIES THAT ARE NOT SHOWN ON PLAN. 7.THE CONTRACTOR IS LIABLE FOR ALL DAMAGES TO PUBLIC OR PRIVATE PROPERTY CAUSED BY THEIR ACTION OR INACTION IN PROVIDING FOR STORM WATER FLOW DURING CONSTRUCTION. DO NOT RESTRICT FLOWS IN EXISTING DRAINAGE CHANNELS, STORM SEWER, OR FACILITIES. 8.LABORATORY TESTS SHALL BE PERFORMED BY THE OWNER UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL PROVIDE SAMPLES OF MATERIAL REQUIRED FOR LABORATORY TESTS AND TESTING IN ACCORDANCE WITH THE URBAN STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS. 9.SOIL IMPORT OR EXPORT ON THIS PROJECT SHALL BE CONSIDERED INCIDENTAL AND WILL NOT BE MEASURED OR PAID FOR SEPARATELY. 10.THE CONTRACTOR SHALL PROTECT ALL STRUCTURES NOT SHOWN AS REMOVALS ON THE PLANS. 11.THE CONTRACTOR SHALL OBTAIN ANY AND ALL NECESSARY PERMITS PRIOR TO ANY CONSTRUCTION. CONTRACTOR SHALL WORK WITH OWNER OR OWNERS REPRESENTATIVE ON ALL REQUIRED STORM WATER DISCHARGE PERMITS FROM THE IOWA DEPARTMENT OF NATURAL RESOURCES AND THE CITY OF WAUKEE, IOWA. 12.GRADING AND EROSION CONTROL SHALL BE DONE IN ACCORDANCE WITH THE APPROVED GRADING PLAN, SWPPP, NPDES DOCUMENTS, AND IOWA DEPARTMENT OF NATURAL RESOURCES REQUIREMENTS. 13.THE CONTRACTOR SHALL PICK UP ANY DEBRIS SPILLED ONTO THE ADJACENT RIGHT OF WAY OR ABUTTING PROPERTIES AS THE RESULT OF CONSTRUCTION, AT THE END OF EACH WORK DAY AND PRIOR TO A RAIN EVENT. 14.THE CONTRACTOR IS RESPONSIBLE FOR THE PROMPT REMOVAL OF ALL MUD THAT HAS BEEN TRACKED OR WASHED UNTO ADJACENT PROPERTY OR RIGHT OF WAY UNTIL SUCH TIME THAT PERMANENT VEGETATION HAS BEEN ESTABLISHED. 15.DISPOSE OF ALL EXCESS MATERIALS AND TRASH IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL REQUIREMENTS. PROVIDE WASTE AREAS OR DISPOSAL SITES FOR EXCESS MATERIALS NOT DESIRABLE FOR INCORPORATION INTO THE PROJECT. PAVING NOTES: 1.THE PAVING/GRADING CONTRACTOR(S) SHALL BACKFILL THE PAVING SLAB AND FINE GRADE THE RIGHT OF WAY AS SOON AFTER THE PAVING AS POSSIBLE. ALL AREAS SHALL BE SODDED IN ACCORDANCE WITH CITY OF WAUKEE, IOWA STANDARD SPECIFICATIONS AND THE CURRENT VERSION OF SUDAS. 2.SUBGRADE PREPARATION AND PAVEMENTS WILL BE CONSTRUCTED FOLLOWING RECOMMENDATIONS IN THE SOILS REPORT. APPROVED SOILS ENGINEER MUST SIGN OFF ON SUBASE PRIOR TO ANY PAVEMENT BEING PLACED. 3.SEE DETAILS FOR ALL PAVEMENT THICKNESS. 4.ALL WALKS, PARKING LOTS, HANDICAP PARKING, RAMPS, ETC. SHALL COMPLY WITH ALL A.D.A. AND CITY CODES. HANDICAP PARKING SIGNAGE IS REQUIRED FOR ALL HANDICAP STALLS AND SHALL BE CONSIDERED INCIDENTAL. IN EVENT OF A DISCREPANCY BETWEEN THE PLANS AND THE A.D.A./CITY CODES THE A.D.A./CITY CODES SHALL GOVERN. CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING A.D.A. CODES ARE MET. 5.PROVIDE 3 4" EXPANSION JOINT BETWEEN ALL P.C.C. PAVEMENT/SIDEWALKS AND BUILDING. PROVIDE 1 2" EXPLANSION JOINT BETWEEN P.C.C. SIDEWALK AND P.C.C. CURB SECTIONS. 6.ALL PROPOSED MAN DOORS TO HAVE 5'x5' STRUCTURAL STOOP TO MATCH GRADING PLAN. STRUCTURAL STOOPS ARE TO BE DESIGNED BY ARCHITECT OF RECORD. UTILITY NOTES: 1.QUANTITY CALLOUTS ON PIPE LENGTHS ARE APPROXIMATE AND SHOULD BE USED FOR REFERENCE ONLY. 2.THE CONTRACTOR SHALL PROVIDE AS-BUILTS OF ALL UTILITIES, INCLUDING DEPTH AND LOCATION OF ALL SERVICES. 3.THE CONTRACTOR SHALL COORDINATE THE ADJUSTMENT OF ANY AND ALL EXISTING AND PROPOSED UTILITIES TO PROPOSED GRADES. EXISTING UTILITIES SHALL BE RAISED OR LOWERED IN ACCORDANCE WITH THE UTILITY OWNER REQUIREMENTS. ANY NECESSARY ADJUSTMENTS SHALL BE CONSIDERED INCIDENTAL TO CONSTRUCTION. 4.ACTIVE EXISTING FIELD TILES ENCOUNTERED DURING CONSTRUCTION SHALL BE REPAIRED, REROUTED, OR CONNECTED TO PUBLIC OR PRIVATE STORM SEWER TO REMAIN IN SERVICE. 5.ALL PROPOSED RCP STORM SEWER PIPE JOINTS SHALL BE FABRIC WRAPPED AND THE LAST 3 PIPE SECTIONS ON THE APRON SHALL BE TIED WITH RF-14 TYPE II CONNECTORS. ALL FES & APRONS SHALL HAVE A STANDARD FOOTING AND TRASH GUARD. 6.ALL RIP RAP CALLED OUT ON PLANS SHALL BE UNDERLAIN WITH ENGINEERING FABRIC. 7.ALL STRUCTURE SIZES CALLED OUT ON PLANS ARE MINIMUM INSIDE WALL DIMENSIONS. 8.SANITARY SEWER SERVICE CONNECTIONS SHALL BE PLACED AT A SLOPE OF NO LESS THAN 2%. SERVICES SHALL MAINTAIN 18" OF VERTICAL SEPARATION FROM THE WATERMAIN WITH 18" OF COMPACTED LOW PERMEABILITY SOIL BETWEEN THE UTILITIES WITHIN 10' OF THE CROSSING. 9.MANDREL AND PRESSURE TESTS SHALL BE REQUIRED FOR ALL PROPOSED SANITARY LINES. TELEVISING OF THE SANITARY SEWER SYSTEM SHALL BE COMPLETED PRIOR TO PAVING UNLESS OTHERWISE APPROVED BY JURISDICTION. 10.WATERMAINS SHALL BE C-900. SIZE OF WATERMAIN AS SHOWN ON PLANS. 11.THRUST BLOCKS SHALL BE INSTALLED AS REQUIRED AND SHALL BE CONSIDERED INCIDENTAL TO WATERMAIN CONSTRUCTION. 12.PROPOSED WATERMAIN SHALL BE PRESSURE TESTED, BACTERIA TESTED AND CHLORINATED. THE FILLING OF THE WATER MAIN SHALL BE DONE BY THE CITY OF WAUKEE, IOWA. 13.TRACER WIRE SHALL BE ADDED TO ALL WATER MAIN, AND BROUGHT TO THE SURFACE AT EVERY HYDRANT. 14.ALL HYDRANTS WILL IMMEDIATELY BE COVERED WITH A BLACK PLASTIC BAG (OR EQUIVALENT) ONCE THE HYDRANT IS INSTALLED. THE CITY OF WAUKEE, IOWA WILL NOTIFY THE CONTRACTOR WHEN THE BAGS CAN BE REMOVED. 15.THE MINIMUM HYDRANT LEAD SHALL BE 3.5 FEET. 16.ANY AND ALL HYDRANT AND VALVE EXTENSIONS, TOGETHER WITH VERTICAL BENDS, SHALL BE CONSIDERED INCIDENTAL TO WATER MAIN CONSTRUCTION. NO ADDITIONAL PAYMENT WILL BE PROVIDED FOR INCIDENTAL ITEMS. DRAWING DATE: PROJECT: SHEET: NO T F O R C O N S T R U C T I O N LO T 1 , J A M E S P O I N T E P L A T 3 WA U K E E , I O W A 220006 6-15-2022 7-19-2022 OR C A C O N S U L T I N G 35 1 2 R I C H L A N D R O A D VA N M E T E R , I O W A 5 0 2 6 1 mi c h a e l @ o r c a c o n s u l t i n g . b i z | ( 5 1 5 ) 7 7 8 - 6 6 0 9 FIRST CITY SUBMITTAL SECOND CITY SUBMITTAL PRELIMINARY BID SET7-14-2022 8-16-2022 THIRD CITY SUBMITTAL 9-9-2022 FOUTH CITY SUBMITTAL UTILITY NOTE THE LOCATION OF THE UTILITIES INDICATED ON THE PLANS HAVE BEEN TAKEN FROM THE FIELD SURVEY, EXISTING PUBLIC RECORDS, AND PLANS PROVIDED BY OTHERS. SURFACE UTILITY LOCATIONS HAVE BEEN FIELD LOCATED BY BISHOP ENGINEERING, UNLESS OTHERWISE NOTED. ALL UNDERGROUND UTILITY LOCATIONS ARE APPROXIMATE LOCATIONS ONLY. BISHOP ENGINEERING DOES NOT GUARANTEE THE UNDERGROUND LOCATION OF ANY UTILITIES SHOWN. IT SHALL BE THE DUTY OF THE CONTRACTOR TO DETERMINE THE LOCATION AND DEPTH OF ANY UNDERGROUND UTILITIES SHOWN AND IF ANY ADDITIONAL UTILITIES, OTHER THAN THOSE SHOWN ON THE PLANS, MAY BE PRESENT. A REQUEST WAS MADE TO IOWA ONE CALL FOR UTILITY PROVIDERS TO VERIFY, LOCATE, AND MARK THEIR UTILITIES IN THE FIELD. ABBREVIATIONS: AC ACRES ASPH ASPHALT BK BOOK CONC CONCRETE D DEEDED DISTANCE EX EXISTING FFE FINISHED FLOOR ELEVATION FL FLOW LINE FRAC FRACTIONAL M MEASURED DISTANCE MH MANHOLE P PLATTED DISTANCE PG PAGE POB POINT OF BEGINNING POC POINT OF COMMENCEMENT PRA PREVIOUSLY RECORDED AS PUE PUBLIC UTILITY EASEMENT ROW RIGHT OF WAY RPC RED PLASTIC CAP SF SQUARE FEET SAN SANITARY TYP TYPICAL YPC YELLOW PLASTIC CAP N NORTH S SOUTH E EAST W WEST UTILITY MAPS REFERENCE C0.1 SITE SURVEY FOR ALL PROVIDER MAPS. STAKING NOTES: 1.CONTRACTOR IS REQUIRED TO HAVE ALL STAKING DONE UNDER THE SUPERVISION OF A LICENSED LAND SURVEYOR AND IN COORDINATION WITH THE PROJECT ENGINEER. 2.CONTRACTOR IS REQUIRED TO HAVE ALL STAKING DONE DIRECTLY UNDER THE GENERAL CONTRACTOR BY A SINGLE COMPANY. 3.STAKING DOES NOT RELIEVE CONTRACTOR OF ULTIMATE RESPONSIBILITY TO CONSTRUCT THE PROJECT PER PLAN. PAVEMENT SAWCUT NOTES: 1.CONTRACTOR TO PROVIDE SAWCUT JOINTING PLAN TO MICHAEL WAHLERT, ORCA CONSULTING (515-778-6609 OR michael@ORCAConsulting.biz) PRIOR TO ANY CONCRETE PAVEMENT INSTALLATION. 2.PAVEMENT MAY BE REQUIRED TO BE REMOVED AND REPLACED IF PLACED WITHOUT AN APPROVED PLAN. 3.LONGITUDINAL JOINTS IN DRIVE LANES & THE OUTER MOST JOINT OF ALL PARKING AREAS SHALL BE SUDAS TYPE 'L-1' OR 'L-2' JOINTS AND HAVE STEEL. INTERIOR PARKING LOT JOINTS, OTHER THAN THE OUTER MOST JOINT, DO NOT NEED STEEL AND SHALL BE SUDAS TYPE 'B' JOINTS. 4.ALL TRANSVERSE JOINTS SHALL BE SUDAS TYPE 'C' OR TYPE 'DW' JOINTS WITH STEEL IN THE CASE OF A DAY'S WORK JOINT. EARTHWORK BALANCE NOTES: 1.SOIL IMPORT OR EXPORT ON THIS PROJECT SHALL BE CONSIDERED INCIDENTAL AND WILL NOT BE MEASURED OR PAID FOR SEPARATELY. CONTRACTOR RESPONSIBLE FOR MAKING THE SITE EARTHWORK BALANCE. 2.THIS INCLUDES BUT IS NOT LIMITED TO TOPSOIL, POOR SOILS AND STRUCTURAL FILL NECESSARY TO MEET PROJECT PLANS AND SPECIFICATIONS. STORM & SANITARY TELEVISING NOTES: 1.CONTRACTOR IS REQUIRED TO TELEVISE ALL SANITARY AND STORM SEWER SYSTEM PRIOR TO PAVING OPERATIONS. 2.CONTRACTOR SHALL SEND VIDEO INSPECTION TO THE ENGINEER FOR APPROVAL PRIOR TO PAVING. 3.CONTRACTOR SHALL PROVIDE COPIES OF THE REPORTS AND VIDEOS TO THE WAUKEE ENGINEERING DEPARTMENT FOR APPROVAL PRIOR TO PAVING. UTILITY CONFLICT NOTES: 1.UTILITY CONFLICTS MAY EXIST ACROSS THE SITE WITH NEW UTILITIES, GRADING, PAVING ETC. MOST UTILITY CONFLICTS HAVE BEEN CALLED OUT FOR CONTRACTOR CONVENIENCE. 2.CONTRACTOR IS RESPONSIBLE FOR ALL UTILITY CONFLICTS THAT ARE EITHER CALLED OUT ON THE PLANS OR THAT CAN BE SEEN ON THE PLANS BETWEEN AN EXISTING UTILITY AND PROPOSED CONSTRUCTION. 3.CONTRACTOR SHALL COMPLY WITH ALL DNR REQUIREMENTS FOR PIPE MATERIAL, PIPE JOINTS, AND ANY OTHER APPLICABLE REQUIREMENTS ANY TIME A STORM SEWER OR SANITARY SEWER CROSSES OVER OR LESS THAN 18" BELOW A WATER MAIN. 4.FOR ALL CRITICAL CROSSINGS WITH EXISTING UTILITIES, THE ELEVATION OF THE EXISTING UTILITY SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. NOTIFY ORCA CONSULTING PRIOR TO CONSTRUCTION IF A CONFLICT EXISTS. 5.ALL STORM SEWER WITH CRITICAL CROSSINGS AT WATER SERVICE TO HAVE GASKETED JOINTS. SPECIFICATIONS NOTES: 1.IN THE EVENT OF A DISCREPANCY BETWEEN THE ORCA CONSULTING PROJECT SPECIFICATIONS AND: CITY OF WAUKEE IOWA REQUIREMENTS AND SPECIFICATIONS, PLUMBING CODE, AND URBAN STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENT (SUDAS 2022 AND 2020 WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS), THE CITY OF WAUKEE, IOWA 2020 STANDARD SPECIFICATIONS SHALL GOVERN. 2.FOR ALL SPECIFICATION DISCREPANCIES, PROJECT ENGINEER SHALL BE CONTACTED PRIOR TO PROCEEDING WITH CONSTRUCTION. IF ENGINEER IS NOT CONTACTED, CONTRACTOR SHALL BE RESPONSIBLE FOR ANY PROBLEMS THAT RESULT FROM SAID DISCREPANCIES. 3.FOR ALL SPECIFICATION DISCREPANCIES, CONTRACTOR MUST OBTAIN WRITTEN APPROVAL FROM THE CITY OF WAUKEE, IOWA ENGINEERING DEPARTMENT FOR ANY CHANGES TO PROPOSED SITE INFRASTRUCTURE OR GRADES PRIOR TO PROCEEDING WITH ANY CHANGES. REQUIRED AS-BUILT NOTES: 1.IF ANYTHING HAS BEEN CONSTRUCTED INCORRECTLY, CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SUBSEQUENT AS-BUILT SURVEYS UNTIL ISSUES HAVE BEEN RECTIFIED. PRELIMINARY C0.1, C1.1, C2.1, C3.1, C4.1, C6.1, C7.1 USE: EXISTING USE - N/A PROPOSED USE: WAREHOUSE/STORAGE BUILDING HEIGHT: PROPOSED HEIGHT = 20' FIRE SAFETY AND CONSTRUCTION NOTE: 1.APPROVED FIRE APPARATUS ACCESS ROADS SHALL BE PROVIDED AS SOON AS CONSTRUCTION COMMENCES. IF PAVING IS NOT INSTALLED PRIOR TO THE BUILDING CONSTRUCTION COMMENCING AFTER FOOTINGS ARE INSTALLED, AN APPROVED ROUTE AROUND THE EXTERIOR OF THE BUILDING TO EXTEND WITHIN 100' OF ALL PORTIONS OF THE EXTERIOR WALLS SHALL BE PROVIDED AND COMPLY WITH THE REQUIREMENTS OF SECTION 503.2 OF THE IFC. PLANS CHANGE NOTE: 1.THE CONTRACTOR SHALL RECEIVE WRITTEN APPROVAL FROM THE WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT FOR ANY CHANGES MADE TO THE PLANS. THE CONTRACTOR IS RESPONSIBLE FOR ANY CHANGES MAKE WITHOUT PERMISSION FROM THE WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT. 1020 1020 1020 10 1 9 10191019 1023 1023 1024 10241024 1025 1025 1025 1027 1026 1028 1026 1027 1028 1029 1026 1027 1027 1027 1028 1028 NW GETTYSBURG LANE (CONCRETE PUBLIC ROAD - 29' B/B - 60' R.O.W.) (1 0 ' P U B L I C U T I L I T Y EA S E M E N T B K . 2 0 2 1 P G . 2 4 5 ) LOT 1 1575 SA N SA N EX SANITARY STUB EX SANITARY STUB D EX STORM MH RIM=1022.70 FL(S 48")=1015.10 FL(N 36")=1014.40 EX INTAKE T/C=1026.58 GUT=1025.95 FL48"(N) = 1017.50 EX INTAKE T/C=1026.64 RIM=1025.99 WV WVHY D WV WV H Y D TBM: BURY BOLT ELEV=1028.82 FO F/O WV WVHY D H Y D TBM: BURY BOLT ELEV=1030.18 WV WV WV H Y D TBM: BURY BOLT ELEV=1030.38 CO EDGE OF POND AT TIME OF SURVEY ELEV = 1018.75 ST 48 " ST 48 " ST 48 " ST 48 " ST 48 " ST 48 " ST ST ST ST SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8" EX LOCATIONS PER CITY OF WAUKEE MAP G G G G G G G G G G G G G W8"W8" W 8"W 8" W8"W 8"W 8"W8"W8"W 8"W8"W8"W8" W6" W6" SA N 8" SA N 8" U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E EX LOCATIONS PER MIDAMERICAN MAP (4 0 ' L A N D S C A P E B U F F E R EA S E M E N T B K . 2 0 2 1 P G . 2 4 7 ) (20' PRIVATE STORM SEWER AND OVERLAND FLOWAGE EAESMENT BK. 2021 PG. 251) APPROACH LOCATION PER CITY PROVIDED SITE PLAN APPROACH LOCATION PER CITY PROVIDED SITE PLAN (20' PRIVATE STORM SEWER AND OVERLAND FLOWAGE EAESMENT BK. 2021 PG. 251) 15 ' S A N I T A R Y S E W E R E A S E M E N T BK 2 0 2 1 P G 2 4 6 10 ' P U E BK . 2 0 2 1 P G 2 4 5 33' SANITARY SEWER EASEMENT BK 2021 PG 246 15' PUE BK 2021 PG 245 48" FES 10 ' P U E BK . 2 0 2 1 P G . 2 4 5 STORM WATER MANAGEMENT FACILITY EASEMENT BK. 2021 PG 252 GRIND OUT 60LF EXISTING CURB GRIND OUT 55LF EXISTING CURB REMOVE & SALVAGE HYDRANT ASSEMBLY PER CITY OF WAUKEE STANDARDS PROTECT EXISTING INTAKE REMOVE & SALVAGE HYDRANT ASSEMBLY PER CITY OF WAUKEE STANDARDS 100' PLAT BOUNDARY OFFSET 100' PLAT BOUNDARY OFFSET DE M O P L A N C1.1 DRAWING DATE: PROJECT: SHEET: NO T F O R C O N S T R U C T I O N LO T 1 , J A M E S P O I N T E P L A T 3 WA U K E E , I O W A 220006 6-15-2022 7-19-2022 OR C A C O N S U L T I N G 35 1 2 R I C H L A N D R O A D VA N M E T E R , I O W A 5 0 2 6 1 mi c h a e l @ o r c a c o n s u l t i n g . b i z | ( 5 1 5 ) 7 7 8 - 6 6 0 9 FIRST CITY SUBMITTAL SECOND CITY SUBMITTAL PRELIMINARY BID SET7-14-2022 8-16-2022 THIRD CITY SUBMITTAL 9-9-2022 FOUTH CITY SUBMITTAL GRAPHIC SCALE 030 15 30 60 OWNER: BACK NINE PROPERTIES LLC. STACY LYMAN 23033 K AVENUE GRUNDY CENTER, IOWA 50638 (319)231-2995 dslyman@me.com PROPOSED BUILDING 1 22,500 SF MOE = 1024.00 FFE = 1027.00 60 . 0 0 ' 375.00' W6" W6" W6" W6" SAN 6"SAN 6" SA N 6" SA N 6" SA N 6" SA N 6" CO W6"W6"W6" 56 . 2 ' CO ST ST ST ST ST ST ST ST ST ST ST ST ST D S T S T CO CO CO 8. 6 8 ' TAPER OUT CURB TOP OF FOUNDATION = 1029.00 TRANSITION TOP OF FOUNDATION 1029.00 TO 1027.75 TRANSITION TOP OF FOUNDATION 102.75 TO 1027.00 TAPER OUT CURB TOP OF FOUNDATION = 1027.75 TRANSITION TOP OF FOUNDATION 1029.00 TO 1027.75 ST ST ST ST ST ST ST ST 4' 7" PCC7" PCC 7" PCC 7" PCC PROPOSED BUILDING 2 24,300 SF MOE = 1024.00 FFE = 1026.35 60 . 0 0 ' 405.00' 3.39' 7" PCC WSO 42 . 8 4 ' 19.59' 31.23' 41 ' 37.8' 32 . 8 2 ' 31 . 0 1 ' 43' R15 ' R15' R50' R50' R 5 . 5 ' R14 . 1 8 ' R1 5 ' R15' 5' 5" PCC SIDELWALK5" PCC SIDELWALK OHD (TYP) REF. ARCH CO CO HY D 5" P C C S I D E L W A L K 5' 7' 8'8' 18 ' 2 18' 9' TAPER OUT CURB OVER 8' RAMP 8.25' 36 . 2 ' 25' 5" PCC SIDELWALK DOWNSPOUT (TYP) DOWNSPOUT (TYP) MANDOOR TO FIRE RISER ROOM MANDOOR TO FIRE RISER ROOM R6' CO ST ST ST ST ST ST TAPER OUT CURB MAN DOOR (TYP) REF. ARCH ST S T S T STST STSTST ST DOWNSPOUT (TYP) (SEE DETAIL C6.1) OHD (TYP) REF. ARCH MAN DOOR (TYP) REF. ARCH DOWNSPOUT (TYP) (SEE DETAIL C6.1) STSTST S TSTST 2' 5' 25'12.9' NW GETTYSBURG LANE (CONCRETE PUBLIC ROAD - 29' B/B - 60' R.O.W.) (6 0 ' R . O . W . ) OWNER: NADAREVIC INVESTMENTS V, LLC ZONED: M-1 (LIGHT INDUSTRIAL) (1 0 ' P U B L I C U T I L I T Y EA S E M E N T B K . 2 0 2 1 P G . 2 4 5 ) LOT 1 (113,949.87 SF - 2.61 ACRES) 1575 SA N SA N SA N SA N (S 0 0 ° 0 6 ' 0 3 " E 2 5 0 . 0 0 ' ) D WV WVHY D WV WV H Y D FO F/O WV WVHY D WV WV WV CO EDGE OF POND AT TIME OF SURVEY ELEV = 1018.75 ST 36 " ST 48 " ST 48 " ST 48 " ST 48 " ST 48 " ST 48 " ST 48 " ST 48 " OW N E R : W A U K E E L A N D I N V E S T M E N T L L C ZO N E D : M - 1 ( L I G H T I N D U S T R I A L ) OWNER: REDWOOD WAUKEE HICKMAN ROAD IA P1, LLC ZONED: R-4 (ROW DWELLING & TOWNHOME DWELLING DISTRICT) REGIONAL DETENTION: (PER CITY SUPPLIED AS-BUILT DRAWINGS) NORMAL POOL = 1011.99 100YR HWEL = 1023.03 OWNER: JAQUES H&D REAL ESTATE, LLC ZONED: M-1 (LIGHT INDUSTRIAL) OWNER: JAQUES H&D REAL ESTATE, LLC ZONED: M-1 (LIGHT INDUSTRIAL) (N 89°53'57" E 230')(N 89°53'57" E 225.82') (S 0 ° 0 6 ' 0 3 " E 2 5 0 ' ) (N 0 ° 0 6 ' 0 3 " W 2 5 0 ' ) (S 89°53'57" W 225.82')(S 89°53'57" W 230') ST 48 " ST 48 " ST ST ST ST (N 89°53'57" E 455.82') SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8" G G G G G G G G G G G G G G G G G G G W8" W 8"W 8"W 8"W 8" W8"W 8"W 8"W 8" W8"W8"W8"W8" W8"W8"W8"W8"W8" W 6" W 6" W 6" W 6" 8" SA N 8" U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/ E U/E (30' BUILDING SETBACK LINE) (3 0 ' B U I L D I N G S E T B A C K L I N E ) (30' BUILDING SETBACK LINE) (4 0 ' L A N D S C A P E B U F F E R EA S E M E N T B K . 2 0 2 1 P G . 2 4 7 ) (20' PRIVATE STORM SEWER AND OVERLAND FLOWAGE EAESMENT BK. 2021 PG. 251) APPROACH LOCATION PER CITY PROVIDED SITE PLAN APPROACH LOCATION PER CITY PROVIDED SITE PLAN (20' PRIVATE STORM SEWER AND OVERLAND FLOWAGE EAESMENT BK. 2021 PG. 251) 15 ' S A N I T A R Y S E W E R E A S E M E N T BK 2 0 2 1 P G 2 4 6 10 ' P U E BK . 2 0 2 1 P G 2 4 5 33' SANITARY SEWER EASEMENT BK 2021 PG 246 15' PUE BK 2021 PG 245 10 ' P U E BK . 2 0 2 1 P G . 2 4 5 STORM WATER MANAGEMENT FACILITY EASEMENT BK. 2021 PG 252 LA Y O U T P L A N C2.1 GRAPHIC SCALE 020 10 20 40 DRAWING DATE: PROJECT: SHEET: NO T F O R C O N S T R U C T I O N LO T 1 , J A M E S P O I N T E P L A T 3 WA U K E E , I O W A 220006 6-15-2022 7-19-2022 OR C A C O N S U L T I N G 35 1 2 R I C H L A N D R O A D VA N M E T E R , I O W A 5 0 2 6 1 mi c h a e l @ o r c a c o n s u l t i n g . b i z | ( 5 1 5 ) 7 7 8 - 6 6 0 9 FIRST CITY SUBMITTAL SECOND CITY SUBMITTAL PRELIMINARY BID SET7-14-2022 8-16-2022 THIRD CITY SUBMITTAL 9-9-2022 FOUTH CITY SUBMITTAL OWNER: BACK NINE PROPERTIES LLC. STACY LYMAN 23033 K AVENUE GRUNDY CENTER, IOWA 50638 (319)231-2995 dslyman@me.com PROPOSED BUILDING 1 22,500 SF MOE = 1024.00 FFE = 1027.00 60 . 0 0 ' 375.00' W 6" W 6" W 6" W 6" 1026.60± EX T/C 1026.10± EX GUT SAN 6"SAN 6" SA N 6" SA N 6" SA N 6" SA N 6" CO W6"W6"W6" 1026.95± EX T/C 1026.45± EX GUT CO 1026.75 1026.10 T/C 1025.85 GUT ST ST ST ST ST ST ST ST ST ST ST ST ST D S T S T CO CO CO 1026.25 1026.25 1026.25 1026.15 1026.60 1025.85 1026.40 1026.151026.15 1026.601026.40 1026.10 2.00%3.00%2.00% 1.00%1.00%1.00% 3.00%4.00% 1026.60 2.00% 1026.20 0.75% 1025.85 127.00 1027.00 1026.40 1026.15 3.00% 1.00% 20 ' 20 ' 1025.80 2.75% 1026.00T/C 1025.50 GUT 1028.55± EX T/C 1028.05± EX GUT 1029.05 T/C 1028.55 GUT 1028.71± EX T/C 1028.21± EX GUT 1029.21 T/C 1028.71 GUT 1026.15 T/C 1025.65 GUT 1026.35 1028.66 1026.95 GUT 1027.00 T/C 1026.50GUT 1026.26 1028.56 T/C 1028.06 GUT TOP OF FOUNDATION = 1029.00 TRANSITION TOP OF FOUNDATION 1029.00 TO 1027.75 TRANSITION TOP OF FOUNDATION 102.75 TO 1027.00 1027.10 T/C 1026.60 GUT 1027.45 T/C 1026.95 GUT 1026.96 T/C 1026.46 GUT 1026.80 T/C 1026.30 GUT 1026.43 T/C 1025.93 GUT 1027.00 T/C 1026.50 GUT 1027.22 T/C 1026.72 GUT 1027.33 T/C 1026.83 GUT 1025.50 1025.85 1027.50 TOP OF FOUNDATION = 1027.75 1026.26 1025.98 1.86% TRANSITION TOP OF FOUNDATION 1029.00 TO 1027.75 1027.50 EM E R G E N C Y O V E R F L O W SW A L E S = 2 . 0 % ST ST ST ST ST ST ST ST 1028.00± EX T/C 1027.50± EX GUT 1 0 2 4 10 2 5 1024 1025 1026 1026 1026 1026 102 8 1029 1028 1024 1025 PROPOSED BUILDING 2 24,300 SF MOE = 1024.00 FFE = 1026.35 60 . 0 0 ' 405.00' 1026.35 10 2 7 1027 WSO 1027.15 1027.15 1026.85 1026.35 1028.25 1028.251028.25 OHD (TYP) REF. ARCH 1027.06± EX 1022.30± EX 1023.48± EX 1024.28± EX 1028.95± EX 1028.41± EX 100YR HWEL1026.07 100YR HWEL 1026.09 100YR HWEL 1025.87 CO CO 2.09 % 2.01 % HY D 1028.57 1028.21 1028.85 1028.80 T/C 1028.30 GUT 1028.75 1029.16 T/C 1028.66 GUT 1029.16 1022.42± EX DOWNSPOUT (TYP) DOWNSPOUT (TYP) MANDOOR TO FIRE RISER ROOM MANDOOR TO FIRE RISER ROOM 8.33%5.88% OVERFLOW ROUTE 1026.25 MAX ELEVATIONOVERFLOW ROUTE 1026.25 1.70% EX 1.75% EX 2.08% EX 1025.08± EX 1026.49± EX 2.19 % 100YR HWEL 1027.51 100YR HWEL 1027.51 100YR HWEL 1027.51 1027.10 T/C 1026.60 GUT 1027.20 CO ST ST ST ST ST ST MAN DOOR (TYP) REF. ARCH ST ST S T STST STSTST ST DOWNSPOUT (TYP) (SEE DETAIL C6.1) OHD (TYP) REF. ARCH MAN DOOR (TYP) REF. ARCH DOWNSPOUT (TYP) (SEE DETAIL C6.1) 1026.35 127.00 100YR HWEL1025.72 OVERFLOW ROUTE 1026.00 MAX ELEVATION STSTST S TSTST 1028.12± EX GUT 3.97%4.14% 1026.24± EX GUT CATASTROPHIC OVER FLOW IS OVERLAND TO GETTYSBURG LN ELEVATION = 1028.00 CATASTROPHIC OVER FLOW IS OVERLAND THE WEST ELEVATION = 1028.25 1020 1020 1020 10 1 9 10191019 1023 1023 1024 10241024 1025 1025 1025 1027 1026 1028 1026 1027 1028 1029 1026 1027 1027 1027 1028 1028 NW GETTYSBURG LANE (CONCRETE PUBLIC ROAD - 29' B/B - 60' R.O.W.) OWNER: NADAREVIC INVESTMENTS V, LLC ZONED: M-1 (LIGHT INDUSTRIAL) (1 0 ' P U B L I C U T I L I T Y EA S E M E N T B K . 2 0 2 1 P G . 2 4 5 ) LOT 1 SA N SA N SA N SA N D WV WVHY D WV WV H Y D FO F/O WV WVHY D WV WV WV CO EDGE OF POND AT TIME OF SURVEY ELEV = 1018.75 ST 36 " ST 48 " ST 48 " ST 48 " ST 48 " ST 48 " ST 48 " ST 48 " ST 48 " OW N E R : W A U K E E L A N D I N V E S T M E N T L L C ZO N E D : M - 1 ( L I G H T I N D U S T R I A L ) OWNER: REDWOOD WAUKEE HICKMAN ROAD IA P1, LLC ZONED: R-4 (ROW DWELLING & TOWNHOME DWELLING DISTRICT) REGIONAL DETENTION: (PER CITY SUPPLIED AS-BUILT DRAWINGS) NORMAL POOL = 1011.99 100YR HWEL = 1023.03 OWNER: JAQUES H&D REAL ESTATE, LLC ZONED: M-1 (LIGHT INDUSTRIAL) OWNER: JAQUES H&D REAL ESTATE, LLC ZONED: M-1 (LIGHT INDUSTRIAL) ST 48 " ST ST ST ST SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8" G G G G G G G G G G G G G G G G G G G W8" W 8"W 8"W 8"W 8" W 8"W 8"W 8"W 8" W8"W8"W8"W8" W8"W8"W8"W8"W8" W6" W6" W 6" W 6" SA N 8" U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/ E U/E (4 0 ' L A N D S C A P E B U F F E R EA S E M E N T B K . 2 0 2 1 P G . 2 4 7 ) (20' PRIVATE STORM SEWER AND OVERLAND FLOWAGE EAESMENT BK. 2021 PG. 251) APPROACH LOCATION PER CITY PROVIDED SITE PLAN APPROACH LOCATION PER CITY PROVIDED SITE PLAN 15 ' S A N I T A R Y S E W E R E A S E M E N T BK . 2 0 2 1 P G 2 4 5 15' PUE BK 2021 PG 245 10 ' P U E BK . 2 0 2 1 P G . 2 4 5 STORM WATER MANAGEMENT FACILITY EASEMENT BK. 2021 PG 252 TOPSOIL NOTES: 1.STRIP AND STOCKPILE IN-SITU ORGANIC TOPSIOL IN ALL DISTURBED AREAS. 2.RESPREAD THE IN-SITU DEPTH OF TOPSOIL IN ALL OPEN SPACE AREAS. 3.TOPSOIL SHALL BE FREE OF ALL ROCK AND DEBRIS LARGER THAN 3/4" IN SIZE. 4.TOPSOIL IS DEFINED AS: FERTILE, FRIABLE LOAM, CAPABLE OF SUSTAINING VIGOROUS PLANT GROWTH, FROM WELL DRAINED SITE FREE FROM FLOODING, NOT IN FROZEN OR MUDDY CONDITIONS; REASONABLE FREE FROM SUBSOIL, CLAY LUMPS, ROOTS, GRASS, WEEDS, STONES LARGER THAN 3/4 INCH IN DIAMETER, AND FOREIGN MATTER; ACIDITY RANGE (PH) OF 5.5 TO 7.5; CONTAINING MINIMUM 4 PERCENT AND MAXIMUM 20 PERCENT ORGANIC MATTER. 5.CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING ALL TOPSOIL REQUIREMENTS OF NPDES GENERAL PERMIT NO. 2 ARE MET. GR A D I N G P L A N C3.1 DRAWING DATE: PROJECT: SHEET: NO T F O R C O N S T R U C T I O N LO T 1 , J A M E S P O I N T E P L A T 3 WA U K E E , I O W A 220006 6-15-2022 7-19-2022 OR C A C O N S U L T I N G 35 1 2 R I C H L A N D R O A D VA N M E T E R , I O W A 5 0 2 6 1 mi c h a e l @ o r c a c o n s u l t i n g . b i z | ( 5 1 5 ) 7 7 8 - 6 6 0 9 FIRST CITY SUBMITTAL SECOND CITY SUBMITTAL PRELIMINARY BID SET7-14-2022 8-16-2022 THIRD CITY SUBMITTAL 9-9-2022 FOUTH CITY SUBMITTAL GRAPHIC SCALE 020 10 20 40 GRADING LEGEND EXISTING CONTOUR PROPOSED CONTOUR FINISHED GROUND/TOP OF SLAB ELEVATION TOP OF CURB ELEVATION GUTTER ELEVATION EXISTING ELEVATION DETECTABLE WARNING (SEE C6.2 FOR DETAIL) 150.50 G 150.50 T/C 150.50 150 150 GRADING NOTES: 1.ALL SPOT GRADES ARE TO THE FINISHED TOP SURFACE OF PCC OR TOP OF SOD IN OPEN SPACE 2.GRADING WITHIN OVERLAND FLOWAGE EASEMENT IS PROHIBITED AND THE EXISTING FINISHED GRADE OF THE 10' EASEMENT IS TO REMAIN AS REPRESENTED IN THE EXISTING SITE SURVEY SUPPLIED WITH THIS PLAN SET. 3.SLOPES IN PAVEMENT TO BE UNIFORM TO AVOID PONDING. 4.CONSTRUCTION OPERATIONS SHALL PROTECT STORM SEWERS AND DRAINAGE WAYS FROM ALLOWING SLURRY FROM CONCRETE OPERATIONS AND DISCHARGE OFFSITE. 150.50± EX OWNER: BACK NINE PROPERTIES LLC. STACY LYMAN 23033 K AVENUE GRUNDY CENTER, IOWA 50638 (319)231-2995 dslyman@me.com ST ST ST ST ST ST ST ST ST ST ST 1027.10 T/C 1026.60 GUT 1027.03 T/C 1026.53 GUT 1027.10 E/W 5.54% 1027.03 E/W 6.25% 1. 5 0 % 1. 3 8 % 1027.05 E/W 1027.00 E/W 1.00% 1. 0 0 % 1.00% 1. 5 0 % 1. 5 0 % 1. 5 0 % 5.65% 6.25%1.00% 1.00% 1027.45 T/C 1026.95 GUT 1027.45 T/C 1026.95 GUT 1027.52 E/W 1027.45 E/W 1027.57 E/W 1027.50 E/W 1026.83 E/W 1026.78 E/W 1. 0 0 % 5' 1026.71 E/W 1026.66 E/W 1. 0 0 % 1027W8"W 8"W 8"W 8"W 8"W 8"W 8"W8"W 8" U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E 1029.21 T/C 1028.71 GUT 1029.13 T/C 1028.63 GUT 1029.21 E/W 6.25% 1029.14 E/W 6.25% 1. 5 0 % 1. 5 0 % 1029.16 E/W 1029.11 E/W 1.00% 1. 5 0 % 1.00% 1. 0 0 % 1. 0 0 % 1. 5 0 % 5.20% 6.25%1.00% 1.00%1029.05 T/C 1028.55 GUT 1028.97 T/C 1028.47 GUT 1029.02 E/W 1028.97 E/W 1028.97 E/W 1028.92 E/W 1028.66 E/W 1028.58 E/W 1028.60 E/W 1028.52 E/W 1. 6 0 % 1. 6 0 % 5' WV CO W8"W8"W8"W 8"W 8"W 8"W8"W8" U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/ E TRANSITION TOP OF FOUNDATION 102.75 TO 1027.00 1026.65 E/W 0.00% 1026.65 E/W 1026.97 E/W 1026.97 E/W 1026.97 E/W 1026.65 E/W 1026.91 E/W 1026.91 E/W 1026.95 E/W 1027.00 E/W 1027.45 E/W 1027.53 E/W 1027.58 E/W 1027.50 E/W 1027.00 E/W 0.00%0.00% 0.00% 1.00% 1.00% 1.00% 1. 5 0 % 1. 5 0 % 6. 2 5 % 6. 2 5 % 1. 7 5 % 1. 7 5 % 1. 7 5 % 0.00% MANDOOR TO FIRE RISER ROOM W6" 1026.95 E/W 8'8' 18 ' 2' 5' 8' 5' 8.25' 5' 1028 150 WEST APPROACH ADA GRADING EXHIBIT AD A G R A D I N G P L A N C3.2 DRAWING DATE: PROJECT: SHEET: NO T F O R C O N S T R U C T I O N LO T 1 , J A M E S P O I N T E P L A T 3 WA U K E E , I O W A 220006 6-15-2022 7-19-2022 OR C A C O N S U L T I N G 35 1 2 R I C H L A N D R O A D VA N M E T E R , I O W A 5 0 2 6 1 mi c h a e l @ o r c a c o n s u l t i n g . b i z | ( 5 1 5 ) 7 7 8 - 6 6 0 9 FIRST CITY SUBMITTAL SECOND CITY SUBMITTAL PRELIMINARY BID SET7-14-2022 8-16-2022 THIRD CITY SUBMITTAL 9-9-2022 FOUTH CITY SUBMITTAL GRAPHIC SCALE 05 2.5 5 10 GRADING LEGEND EXISTING CONTOUR PROPOSED CONTOUR SIDEWALK TOP OF SLAB ELEVATION TOP OF CURB ELEVATION GUTTER ELEVATION EXISTING ELEVATION DETECTABLE WARNING (SEE C6.2 FOR DETAIL) 150.50 G 150.50 T/C 150.50 E/W 150 150.50± EX OWNER: BACK NINE PROPERTIES LLC. STACY LYMAN 23033 K AVENUE GRUNDY CENTER, IOWA 50638 (319)231-2995 dslyman@me.com EAST APPROACH ADA GRADING EXHIBIT ADA PARKING GRADING EXHIBIT PROPOSED BUILDING 1 22,500 SF MOE = 1024.00 FFE = 1027.00 60 . 0 0 ' 375.00' W 6" W 6" W 6" W 6" SAN 6"SAN 6" SA N 6" SA N 6" SA N 6" SA N 6" CO W6"W6"W6"CO D ** CRITICAL CROSSING** BEND WATER UNDER STORM & SANITARY PIPE W/MINIMUM 1.5' SEPARATION (SEE DETAIL C6.1) EX CLEANOUT RIM = 1027..15 INV(N,W) = 1016.09 INV(S) = 1016.09± EX CLEANOUT RIM = 1028.25 INV = 1014.97 EX CLEANOUT ADJUST RIM TO = 1028.15 INV(S,N)= 1014.77± EX CO CLEANOUT RIM = 1028.15 INV = 1016.25 CLEANOUT RIM = 1026.00 INV(N,W) = 1018.37 INV(S) = 1018.37 ** CRITICAL CROSSING** BOTTOM 6" SAN = 1017.74 TOP 18" STORM = 1016.37 MPP 1,000GAL SAND/OIL SEP. (SEE DETAIL C6.1) RIM(E,W) = 1027.15 INV(W) = 1016.74 INV (E) = 1016.49 8 LF 6" SANITARY SERVICE @ S=5.0% CO 8 LF 6" SANITARY SERVICE @ S=5.0% CLEANOUT RIM = 1027.15 INV(N) = 1017.15 INV(E) = 1017.15 11 LF 6" SANITARY SERVICE @ S=5.0% INV = 1016.62 (REF. ARCH FOR CONTINUATION) 10 LF 6" SAN. SERVICE @ S=5.0% INV = 1017.64 (REF. ARCH FOR CONTINUATION) WATER SERVICE SPLIT (SEE DETAIL C6.1) 4 LF 6" SAN. PIPE @ S=2.0% INV = 1018.45 (REF. ARCH FOR CONTINUATION) 65 L F 6 " S A N I T A R Y P I P E @ S = 1 . 5 0 % 83 LF 6" SANITARY SERVICE @ S = 1.50% COMPP 1,000GAL SAND/OIL SEP. (SEE DETAIL C6.1) RIM(N) = 1025.65 RIM(S) = 1025.85 INV(N) = 1018.68 INV (S) = 1018.43 3 LF 6" SAN. PIPE @ S=2.0% 4 LF 6" SAN. PIPE @ S=2.0% INV = 1018.81 (REF. ARCH FOR CONTINUATION) CLEANOUT RIM = 1025.60 INV(W) = 1018.73 INV(S) = 1018.73 TRANSFORMER & PAD (SEE DETAIL C6.1) TRANSFORMER & PAD (SEE DETAIL C6.1) ADJUST CLEANOUT RIM TO MATCH PAVEMENT 10 LF 6" SANITARY SERVICE @ S = 2.0%TWO (2) 45° 6" BENDS TWO (2) 45° 6" BENDS STORM STR. #1 18" FES FL = 1012.00 7 1 L F 1 8 " N - 1 2 @ S = 1 . 5 0 % 167LF 18" N-12 @ S = 1.95%108LF 24" N-12 @ S = 1.00% 85 L F 2 4 " N - 1 2 @ S = 1 . 5 0 % STORM STR. #2 SW-401 W/SW-602 CASTING (OR EQUIVALENT) INTERNAL WEIR WALL WITH TOP WEIR ELEV =1022.67 WEIR WALL TO HAVE 3" ORIFICE FL=1013.25 RIM = 1024.67 FL(S) = 1013.25 FL(NE) = 1013.15 STORM STR. #3 SW-501 W/SW-603 TYPE 6 CASTING (OR EQUIVALENT) 100YR HWEL = 1025.87 T/C = 1026.15 FL(W) = 1014.60 FL(N) = 1014.50 STORM STR. #4 SW-511 W/SW-604 TYPE 6 CASTING (OR EQUIVALENT) 100YR HWEL = 1026.09 RIM = 1025.85 FL(W) = 1017.92 FL(E) = 1017.82 FL(8") = 1018.00 STORM STR. #5 SW-511 W/SW-604 TYPE 6 CASTING (OR EQUIVALENT)100YR HWEL = 1026.07 RIM = 1025.85 FL(W) = 1019.10 FL(E) = 1019.00 FL(8") = 1020.00 TOP OF FOUNDATION = 1029.00 TRANSITION TOP OF FOUNDATION 1029.00 TO 1027.75 TRANSITION TOP OF FOUNDATION 102.75 TO 1027.00 TOP OF FOUNDATION = 1027.75 TRANSITION TOP OF FOUNDATION 1029.00 TO 1027.75 CORE DRILL 8" PIPE INTO STRUCTURE **NOT TO BE INSTALLED IN CORNER OF STRUCTURE** FL(12") = 1021.50 STORM STR. # 7 15" NYLOPLAST BASIN W/DOME GRATE RIM = 1026.85 FL(E,SW) = 1021.61 STORM STR. # 8 12" NYLOPLAST BASIN W/DOME GRATE 100YR HWEL = 1027.51 RIM = 1027.15 FL(E,W) = 1022.32 STORM STR. # 9 12" NYLOPLAST BASIN W/DOME GRATE 100YR HWEL= 1027.51 RIM = 1027.15 FL(W) = 1022.82 PROPOSED BUILDING 2 24,300 SF MOE = 1024.00 FFE = 1026.35 60 . 0 0 ' 405.00' FDC 23LF 12" N-12 @ S = 0.50% 142LF 12" N-12 @ S = 0.50% 99LF 12" N-12 @ S = 0.50% ** CRITICAL CROSSING** TOP 6" SAN = 1016.42 BOTTOM 12" STORM = 1021.86 ** CRITICAL CROSSING** BEND WATER UNDER STORM PIPE W/MINIMUM 1.5' SEPARATION (SEE DETAIL C6.1) CONNECT TO EXISTING WATER SERVICE W/WSO WSO 95LF 6" WATER SERVICE 137LF 6" WATER SERVICE OHD (TYP) REF. ARCH CO CO H YD 100' HYDRANT RADIUS R 1 5 0 ' R150' 6"x6" T.S.&V & HYDRANT ASSEMBLY (REUSE EX. BLOWOFF HYDRANT ASSEMBLY) 5' 8" ROOFDRAIN (TYP) WYE INTO TOP OF 18" (SEE DETAIL C6.1) 100YR HWEL1026.07 100YR HWEL 1026.09 100YR HWEL 1025.87 R150 ' FDC DOWNSPOUT (TYP) DOWNSPOUT (TYP) MANDOOR TO FIRE RISER ROOM MANDOOR TO FIRE RISER ROOM OVERFLOW ROUTE 1026.25 MAX ELEVATION **CRITICAL CROSSING** BEND WATER UNDER STORM PIPE W/MINIMUM 1.5' SEPARATION BOTTOM 12" STORM = 1021.36 (SEE DETAIL C6.1) 100YR HWEL 1027.51 100YR HWEL 1027.51 CO CLEANOUT RIM = 1026.75 INV = 1017.22 78 L F 6 " S A N I T A R Y P I P E @ S = 1 . 5 0 % STORM STR. #6 SW-501 W/SW-603 TYPE 6 CASTING (OR EQUIVALENT)100YR HWEL = 1025.80 T/C = 1026.00 FL(E) = 1020.67 WATER SERVICE SPLIT (SEE DETAIL C6.1) MAN DOOR (TYP) REF. ARCH 6"x6" TEE DOWNSPOUT (TYP) (SEE DETAIL C6.1) OHD (TYP) REF. ARCH MAN DOOR (TYP) REF. ARCH DOWNSPOUT (TYP) (SEE DETAIL C6.1) 158LF 24" N-12 @ S = 1.00% OVERFLOW ROUTE 1026.25 MAX ELEVATIONOVERFLOW ROUTE 100YR HWEL1025.72 OVERFLOW ROUTE 1026.00 MAX ELEVATION R150' ** CRITICAL CROSSING** BEND WATER UNDER SANITARY PIPE W/MINIMUM 1.5' SEPARATION (SEE DETAIL C6.1) NW GETTYSBURG LANE (CONCRETE PUBLIC ROAD - 29' B/B - 60' R.O.W.) (1 0 ' P U B L I C U T I L I T Y EA S E M E N T B K . 2 0 2 1 P G . 2 4 5 ) LOT 1 SA N SA N SA N SA N EX SANITARY STUB EX SANITARY STUB D EX STORM MH RIM=1022.70 FL(S 48")=1015.10 FL(N 36")=1014.40 EX INTAKE T/C=1026.58 GUT=1025.95 FL48"(N) = 1017.50 EX INTAKE T/C=1026.64 RIM=1025.99 WV WVHY D TBM: BURY BOLT ELEV=1028.57 WV WV H Y D FO F/O WV WVHY D TBM: BURY BOLT ELEV=1029.61 WV WV WV CO EDGE OF POND AT TIME OF SURVEY ELEV = 1018.75 ST 36 " ST 48 " ST 48 " ST 48 " ST 48 " ST 48 " ST 48 " ST 48 " ST 48 " OW N E R : W A U K E E L A N D I N V E S T M E N T L L C ZO N E D : M - 1 ( L I G H T I N D U S T R I A L ) OWNER: REDWOOD WAUKEE HICKMAN ROAD IA P1, LLC ZONED: R-4 (ROW DWELLING & TOWNHOME DWELLING DISTRICT) REGIONAL DETENTION: (PER CITY SUPPLIED AS-BUILT DRAWINGS) NORMAL POOL = 1011.99 100YR HWEL = 1023.03 OWNER: JAQUES H&D REAL ESTATE, LLC ZONED: M-1 (LIGHT INDUSTRIAL) OWNER: JAQUES H&D REAL ESTATE, LLC ZONED: M-1 (LIGHT INDUSTRIAL) ST 48 " ST ST ST ST SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8" EX LOCATIONS PER CITY OF WAUKEE MAP G G G G G G G G G G G G G G G G G G G G 8"W8" W 8"W8"W 8"W 8" W 8"W8"W 8"W8" W8"W8"W8"W8" W8"W8"W8"W8"W8" W 6" W 6" W6" W6" U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/ E U/E EX LOCATIONS PER MIDAMERICAN MAP (30' BUILDING SETBACK LINE) (3 0 ' B U I L D I N G S E T B A C K L I N E ) (30' BUILDING SETBACK LINE) (4 0 ' L A N D S C A P E B U F F E R EA S E M E N T B K . 2 0 2 1 P G . 2 4 7 ) (20' PRIVATE STORM SEWER AND OVERLAND FLOWAGE EAESMENT BK. 2021 PG. 251) APPROACH LOCATION PER CITY PROVIDED SITE PLAN APPROACH LOCATION PER CITY PROVIDED SITE PLAN 15' PUE BK 2021 PG 245 10 ' P U E BK . 2 0 2 1 P G . 2 4 5 STORM WATER MANAGEMENT FACILITY EASEMENT BK. 2021 PG 252 UTILITY NOTES: 1.ALL PROPOSED UTILTIES SHALL BE PRIVATE, UNLESS NOTED OTHERWISE. 2.ALL WATER LINES SHALL HAVE A MINIMUM OF 5.5' OF COVER UNLESS NOTED OTHERWISE. 3.FIRE HYDRANT ASSEMBLY SHALL INCLUDE THE TEE, BRANCH, VALVE AND HYDRANT OR INSTALLED PER CITY OF WAUKEE WATER WORKS. 4.NYLOPLAST DRAIN BASINS ARE APPROVED AS EQUIVALENTS FOR ALL CURRENTLY SPECIFIED SUDAS STORM MANHOLES AND INTAKES EXCLUDING SW-513. NYLOPLAST DRAIN BASINS SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 5.PIPE LENGTHS CALLED OUT ON PLANS INCLUDE FLARED END SECTION, WHERE APPLICABLE. 6.STORM SEWER CALLED OUT AS RCP MUST BE CLASS III RCP. 7.STORM SEWER CALLED OUT AS N-12 MAY BE EITHER N-12 OR CLASS III RCP. 8.FOR RCP PIPE, ASSOCIATED F.E.S. MUST BE RCP. FOR N-12 PIPE, ASSOCIATED F.E.S. SHALL BE CMP. 9.TRANSFORMER PAD IS SHOWN FOR REFERENCE ONLY AND MAY NOT BE DRAWN TO ACTUAL SIZE. PAD SHALL CONFORM TO ALL UTILITY COMPANY DESIGN STANDARDS AND SPECIFICATIONS. 10.CITY OF WAUKEE TO BORE GAS SERVICE UNDER NW GETTYSBURG LANE AND CONNECT TO PROPOSED GAS METER LOCATIONS SHOWN ON PLANS. 11.GAS SERVICE LINES SHOWN ON PLANS ARE FOR ILLUSTRATION ONLY, CITY OF WAUKEE WILL ULTIMATELY DICTATE GAS SERVICE LOCATION TO CONNECT TO GAS METER PROPOSED ON EACH BUILDING. 12.ALL GAS CRITICAL CROSSINGS SHOWN AND NOT SHOWN TO HAVE A MINIMUM SEPARATION TO ANY OTHER UTILITY OF 1.5' WHILE MAINTAINING AT LEAST 40" OF COVER ON GAS SERVICE UNLESS OTHERWISE DICTATED BY CITY OF WAUKEE, IOWA. 13.REFER TO M.E.P. PLANS FOR UTILITY SERVICE SIZES AND EXACT LOCATIONS. REFER TO ELECTRICAL PLANS FOR ELECTRIC AND TELEPHONE SERVICE CONSTRUCTION DETAILS. REFER TO MECHANICAL PLANS FOR GAS SERVICE CONSTRUCTION DETAILS. 14.FIELD VERIFY ELEVATIONS AND LOCATIONS OF ALL CONNECTIONS TO EXISTING UTILITIES PRIOR TO COMMENCING CONSTRUCTION. 15.BACKFILL ALL UTILITY TRENCHES ACCORDING TO THE 2022 EDITION OF THE SUDAS STANDARD SPECIFICATIONS AND THE 2020 WAUKEE SPECIFICATIONS FOR PUBLIC IMPROVEMENTS. UT I L I T Y P L A N C4.1 DRAWING DATE: PROJECT: SHEET: NO T F O R C O N S T R U C T I O N LO T 1 , J A M E S P O I N T E P L A T 3 WA U K E E , I O W A 220006 6-15-2022 7-19-2022 OR C A C O N S U L T I N G 35 1 2 R I C H L A N D R O A D VA N M E T E R , I O W A 5 0 2 6 1 mi c h a e l @ o r c a c o n s u l t i n g . b i z | ( 5 1 5 ) 7 7 8 - 6 6 0 9 FIRST CITY SUBMITTAL SECOND CITY SUBMITTAL PRELIMINARY BID SET7-14-2022 8-16-2022 THIRD CITY SUBMITTAL 9-9-2022 FOUTH CITY SUBMITTAL GRAPHIC SCALE 020 10 20 40 OWNER: BACK NINE PROPERTIES LLC. STACY LYMAN 23033 K AVENUE GRUNDY CENTER, IOWA 50638 (319)231-2995 dslyman@me.com PROPOSED BUILDING 1 22,500 SF MOE = 1024.00 FFE = 1027.00 60 . 0 0 ' 375.00' W 6" W 6" W 6" W6" SAN 6"SAN 6" SA N 6" SA N 6" SA N 6" SA N 6" CO W6"W6"W6"CO D CO CO CO TOP OF FOUNDATION = 1029.00 TRANSITION TOP OF FOUNDATION 1029.00 TO 1027.75 TRANSITION TOP OF FOUNDATION 102.75 TO 1027.00 TOP OF FOUNDATION = 1027.75 TRANSITION TOP OF FOUNDATION 1029.00 TO 1027.75 PROPOSED BUILDING 2 24,300 SF MOE = 1024.00 FFE = 1026.35 60 . 0 0 ' 405.00' WSO (30) REQUIRED EVERGREEN TREES (20) REQUIRED OVER STORY TREES (40) REQUIRED ORNAMENTAL TREES ***SEE LIST OF APPROVED SPECIES PER CITY OF WAUKEE STANDARDS*** OHD (TYP) REF. ARCH CO CO HYD DOWNSPOUT (TYP) DOWNSPOUT (TYP) MANDOOR TO FIRE RISER ROOM MANDOOR TO FIRE RISER ROOM CO MAN DOOR (TYP) REF. ARCH DOWNSPOUT (TYP) (SEE DETAIL C6.1) OHD (TYP) REF. ARCH MAN DOOR (TYP) REF. ARCH DOWNSPOUT (TYP) (SEE DETAIL C6.1) 1020 1020 1020 10 1 9 10191019 1023 1023 1024 10241024 1025 1025 1025 1027 1026 1028 1026 1027 1028 1029 1026 1027 1027 1027 1028 1028 NW GETTYSBURG LANE (CONCRETE PUBLIC ROAD - 29' B/B - 60' R.O.W.) (1 0 ' P U B L I C U T I L I T Y EA S E M E N T B K . 2 0 2 1 P G . 2 4 5 ) LOT 1 (113,949.87 SF - 2.61 ACRES) SA N SA N SA N SA N D WV WVHY D WV WV H Y D FO F/O WV WVHY D WV WV WV CO EDGE OF POND AT TIME OF SURVEY ELEV = 1018.75 ST 36 " ST 48 " ST 48 " ST 48 " ST 48 " ST 48 " ST 48 " ST 48 " ST 48 " (N 89°53'57" E 230')(N 89°53'57" E 225.82') (S 0 ° 0 6 ' 0 3 " E 2 5 0 ' ) (N 0 ° 0 6 ' 0 3 " W 2 5 0 ' ) (S 89°53'57" W 225.82')(S 89°53'57" W 230') ST W 8" W 8"W 8"W 8"W8" W 8"W8"W 8"W8" W8"W8"W8"W8" W8"W8"W8"W8" U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/ E (30' BUILDING SETBACK LINE) (3 0 ' B U I L D I N G S E T B A C K L I N E ) (30' BUILDING SETBACK LINE) (4 0 ' L A N D S C A P E B U F F E R EA S E M E N T B K . 2 0 2 1 P G . 2 4 7 ) (20' PRIVATE STORM SEWER AND OVERLAND FLOWAGE EAESMENT BK. 2021 PG. 251) LANDSCAPE NOTES: 1.ALL SODDING & LANDSCAPE PLANTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE URBAN STANDARD SPECIFICATIONS, UNLESS SPECIFIED OTHERWISE. 2.SOD ALL DISTURBED AREAS WITHIN THE CONTRACT LIMITS, UNLESS NOTED OTHERWISE. SOD LIMITS SHOWN ON PLAN ARE FOR REFERENCE ONLY. FINAL LIMITS MAY CHANGE BASED ON CONSTRUCTION ACTIVITIES. DISTURBED ROW TO BE STABILIZED WITH SOD. 3.STAKE SOD ON ALL SLOPES 3 : 1 OR GREATER. 4.PLANT QUANTITIES ARE FOR CONTRACTORS CONVENIENCE, THE DRAWING SHALL PREVAIL IF A CONFLICT OCCURS. 5.ALL PLANT MATERIAL SHALL CONFORM TO THE LATEST EDITION OF THE AMERICAN STANDARD FOR NURSERY STOCK (ANSI Z60.1). 6.CONTRACTOR SHALL GUARANTEE ALL PLANT MATERIAL FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE. 7.IT IS THE CONTRACTORS RESPONSIBILITY TO REMOVE IDENTIFICATION TAGS AND CORDS ON ALL PLANT MATERIAL PRIOR TO THE COMPLETION OF THE CONTRACT. IDENTIFICATION TAGS MUST BE LEFT ON UNTIL AFTER ACCEPTANCE BY OWNER OR OWNER'S REPRESENTATIVE. 8.CONTRACTOR SHALL PLACE SHREDDED HARDWOOD MULCH AROUND ALL TREES, SHRUBS AND GROUND COVER BEDS TO A DEPTH OF 4 INCHES, UNLESS NOTED. 9.STAKE AND WRAP ALL DECIDUOUS TREES IMMEDIATELY AFTER PLANTING. STAKE ALL TREES ACCORDING TO THE STAKING DETAILS. CONTRACTOR SHALL ADJUST AND MAINTAIN GUYING TENSION THROUGHOUT THE PLANT ESTABLISHMENT PERIOD. 10.THE LANDSCAPING CONTRACTOR SHALL HAVE ALL UTILITIES LOCATED BEFORE STARTING ANY SITE WORK OR PLANTING. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING UTILITIES. 11.NO LANDSCAPE MATERIAL SHALL BE SUBSTITUTED WITHOUT THE AUTHORIZATION OF THE CIVIL ENGINEER OF RECORD. 12.ALL EDGING SHALL BE DURAEDGE 1/8" STEEL EDGING - COLOR GREEN, OR APPROVED EQUAL.. 13.CONTRACTOR SHALL BE RESPONSIBLE MAINTAINING APPROPRIATE LEVEL OF WATERING FOR ALL NEW PLANTS FOR A PERIOD OF 30 DAYS. 14.ALL SHRUB AND PERENNIAL PLANTING BEDS SHALL BE MULCHED WITH 4" THICK SHREDDED HARDWOOD MULCH. 14.ALL SHRUB AND PERENNIAL PLANTING BEDS SHALL INCORPORATE TYPAR 3301 NONWOVEN LANDSCAPE FABRIC (OR SIMILAR) AND 3" THICK LAYER OF WASHED RIVER ROCK (1.5" NOMINAL SIZE). 15.ALL BEDS TO RECEIVE GRANULAR PRE-EMERGENT WEED CONTROL BEFORE AND AFTER MULCH/ROCK IS INSTALLED. 16.ALL LANDSCAPE REQUIRED BELOW TO BE PLANED WITHIN THE LANDSCAPE BUFFER. NUMBER OF PLANTINGS IS GOVERNED BY THE SCHEDULE LISTED IN THE GENERAL LANDSCAPE REQUIREMENTS BELOW, AND NOT WHAT IS SHOWN ON THIS PLAN SHEET. LA N D S C A P E P L A N C5.1 DRAWING DATE: PROJECT: SHEET: NO T F O R C O N S T R U C T I O N LO T 1 , J A M E S P O I N T E P L A T 3 WA U K E E , I O W A 220006 6-15-2022 7-19-2022 OR C A C O N S U L T I N G 35 1 2 R I C H L A N D R O A D VA N M E T E R , I O W A 5 0 2 6 1 mi c h a e l @ o r c a c o n s u l t i n g . b i z | ( 5 1 5 ) 7 7 8 - 6 6 0 9 FIRST CITY SUBMITTAL SECOND CITY SUBMITTAL PRELIMINARY BID SET7-14-2022 8-16-2022 THIRD CITY SUBMITTAL 9-9-2022 FOUTH CITY SUBMITTAL GRAPHIC SCALE 020 10 20 40 DO NOT CUT CENTRAL LEADER WRAP TRUNK WITH APPROVED TREE WRAP TO FIRST BRANCH 4" DEEP HARDWOOD MULCH CUT SYNTHETIC CORDS AROUND ROOTBALL AND TRUNK -ENTIRELY REMOVE WIRE BASKETS FROM BALL SET ROOTBALL ON UNDISTURBED SUBGRADE DECIDUOUS TREE PLANTING (TYP.) NOT TO SCALESCALE: SCARIFY SIDES & BOTTOM OF PLANTING PIT STAKING ORIENTATION NORTH NORTH 2 STAKES - 3" CAL. & LESS 3 STAKES - GREATER THAN 3" CAL. 3'-0"SET ROOTBALL FLUSH WITH FINISHED GRADE DO NOT PLACE MULCH IN CONTACT WITH BASE OF TREE PRUNE ANY DEAD/DAMAGED BRANCHING FROM TREE. MAINTAIN OVERALL APPEARANCE. USE HOSE GUARDS AROUND TRUNK ON STAKING WIRE. TIE WIRE TO STEEL POSTS PLACED OUTSIDE PLANT PIT.. LEAVE STAKES IN PLACE NO MORE THAN 1 YEAR FROM INSTALLATION. CONTRACTOR RESPONSIBLE FOR REMOVAL. 4" DEPTH SHREDDED HARDWOOD MULCH SCARIFY SIDES & BOTTOM OF PLANTING PIT EVERGREEN TREE PLANTING (B&B) NOT TO SCALESCALE: CUT SYNTHETIC CORDS AROUND ROOTBALL AND TRUNK -ENTIRELY REMOVE WIRE BASKETS FROM BALL SET ROOTBALL ON UNDISTURBED SUBGRADE 3'-0" DO NOT PLACE MULCH IN CONTACT WITH BASE OF TREE DECIDUOUS SHRUB DETAIL EVERGREEN SHRUB DETAIL PLANTING ON SLOPES FIRMLY COMPACT SAUCER (USE TOPSOIL) ORIGINAL GROUND LINE SUB-SOIL 4" MULCH PLANTING PIT TWICE THE WIDTH OF ROOTBALL 1 2 SHRUB PLANTING (TYP) NOT TO SCALESCALE: 3" ROCK GENERAL LANDSCAPE REQUIREMENTS LANDSCAPE BUFFER REQUIREMENT PER 50' OF LANDSCAPE BUFFER (2 OVERSTORY, 4 EVERGREEN, 3 ORNAMENTAL) TOTAL LANDSCAPE BUFFER = 455' THEREFORE REQUIRED PLANTINGS ARE AS FOLLOWS: TOTAL REQUIRED OVERSTORY 2 x 10 =20 TOTAL REQUIRED EVERGREEN 3 x 10 =30 TOTAL REQUIRED ORNAMENTAL 4 x 10 =40 OVERSTORY TREE SPECIES: RED OAK (QUERCUS RUBRA) EVERGREEN TREE SPECIES: WHITE PINE (PINUS STROBUS) ORNAMENTAL TREE SPECIES: REDBUD (CERCIS CANADENSIS) SOD: PROVIDE AND INSTALL SOD FROM LOCAL SUPPLIERS. ALL DISTURBED AREAS TO BE SODDED & MUST BE FREE OF ALL CONSTRUCTION DEBRIS AND ANY DIRT CLUMPS OVER 1" IN DIAMETER. THOROUGHLY WATER SOD UPON INSTALLATION. CONTRACTOR TO MAINTAIN WATERING UNTIL SOD IS ESTABLISHED (ROOTS KNITTED INTO SUBSURFACE) OWNER: BACK NINE PROPERTIES LLC. STACY LYMAN 23033 K AVENUE GRUNDY CENTER, IOWA 50638 (319)231-2995 dslyman@me.com DE T A I L S S H E E T C6.1 DRAWING DATE: PROJECT: SHEET: NO T F O R C O N S T R U C T I O N LO T 1 , J A M E S P O I N T E P L A T 3 WA U K E E , I O W A 220006 6-15-2022 7-19-2022 OR C A C O N S U L T I N G 35 1 2 R I C H L A N D R O A D VA N M E T E R , I O W A 5 0 2 6 1 mi c h a e l @ o r c a c o n s u l t i n g . b i z | ( 5 1 5 ) 7 7 8 - 6 6 0 9 FIRST CITY SUBMITTAL SECOND CITY SUBMITTAL PRELIMINARY BID SET7-14-2022 8-16-2022 THIRD CITY SUBMITTAL 9-9-2022 FOUTH CITY SUBMITTAL D A A FLARED END SECTION FLARED END SECTION #4 BARS @18" ON CENTER CONCRETE FOOTING UNDISTURBED SOIL PIPE BEDDING FLARED END SECTION FOOTING AND OUTLET DETAIL NOT TO SCALE F VARIES SAME DIMENSION AS END SECTION 6" F 1'- 8" ELEVATION SECTION A-A W 6" 6" F I R E 2" D O M E S T I C BUILDING5' M I N WATER SERVICE DETAIL NOT TO SCALE 6" GATE VALVE & BOX 6"X6" TEE 2" GATE VALVE & BOX 2"X6" REDUCER REFERENCE ARCH. OR MEP FOR CONTINUATION FROM GATE VALE(S) 5' FROM FACE OF FOUNDATION OR PER PLAN 18 " M I N STORM OR SANITARY SEWER WATER MAIN LOCATED ONE FULL LENGTH OF PIPE SO BOTH JOINTS ARE AS FAR AS POSSIBLE FROM THE WATER MAIN NOTES: 1.THIS DETAIL SHALL APPLY ANY TIME A STORM SEWER OR SANITARY SEWER CROSSES OVER OR LESS THAN 18 INCHES BELOW A WATER MAIN. 2.WHEN WATER MAIN CROSSES UNDER STORM OR SANITARY SEWER THE CONTRACTOR SHALL MAINTAIN A MINIMUM OF 18" OF SEPARATION. 3.STORM OR SANITARY SEWER MAY NOT BE PLACED CLOSER THAN 6" BELOW A WATER MAIN. 4.MAINTAIN THE MAXIMUM FEASIBLE SEPARATION IN ALL CASES. 5.SEWER AND WATER PIPES MUST BE ADEQUATELY SUPPORTED & HAVE WATERTIGHT JOINTS. 6.CONTRACTOR SHALL INSTALL LOW PERMEABILITY SOIL FOR BACKFILL MATERIAL WITHIN 10 FEET OF THE CROSSING. 7.IN SANITARY SEWER CROSSINGS, CONTRACTOR SHALL INSTALL ONE FULL LENGTH OF SANITARY SEWER OF WATER MAIN PIPE MATERIAL WITH WATERTIGHT JOINTS LOCATED AS FAR AS POSSIBLE FROM THE CROSSING. 8.IN STORM SEWER CROSSINGS, THE CONTRACTOR SHALL INSTALL ON FULL LENGTH OF STORM SEWER PIPE OF WATER MAIN MATERIAL OR RCP WITH FLEXIBLE O-RING GASKET JOINTS SO BOTH JOINTS ARE LOCATED AS FAR AS POSSIBLE FROM THE CROSSING. 9.GASKETED JOINTS SHALL COMPLY WITH ASTM C443. 6" - 1 8 " WATER MAIN WATER MAIN & STORM OR SANITARY SEWER CROSSING DETAIL NOT TO SCALE 6" 48 " VARIES 24 " 1/2" FOAM AROUND BOLLARD SEAL FOAM W/ GRAY MASTIC JOINT SEALANT CLASS "A" CONCRETE FOUNDATION CENTERED ON BOLLARD 7" PCC SLAB SEE OTHER DETAILS INSTALL BOLLARD 24" INTO SLAB MEASURED FROM FACE OF FOUNDATION STALL TO CENTER OF BOLLARD 6" DIA WEATHERED (COR-TEN) STEEL PIPE EMBEDDED IN CONCRETE FILL PIPE W/ CONCRETE BOLLARD DETAIL SCALE: NONE 36 " 20" 7" PCC SLAB SEE OTHER DETAILS NOT TO SCALE STD. P.C.C. PAVING & CURB DETAIL R 2" R 1" 6" 6" 4.5"3" 12" COMPACTED SUBGRADE 95% STD PROCTOR 7" P.C.C. (4000 PSI) 2-6" LIFTS TRANSFORMER PAD MOAT DETAIL NOT TO SCALE REINFORCED CONCRETE TRANSFORMER PAD (PER MID-AMERICAN STANDARDS) REFERENCE ELECTRICAL PLANS TRANSFORMER 3' 3' 3' 3' 3" RIVER ROCK, SCREENED DURAEDGE 1/8" STEEL EDGING, COLOR GREEN REINFORCED CONCRETE TRANSFORMER PAD (PER MID-AMERICAN STANDARDS) 3" RIVER ROCK, SCREENED 3' 2'2' 3'LINE TRENCH WITH SILT FENCE FABRIC (OR OTHER SOIL FABRIC WITH EQUAL OR LOWER POROSITY) DURAEDGE 1/8" STEEL EDGING, COLOR GREEN 40 " M I N . D E P T H FLOOR SLAB DOWNSPOUT CONNECTION DETAIL NOT TO SCALE EXTERIOR WALL DOWNSPOUT (REF ARCH) INSTALL CAP ON STORM PIPE AND EXTEND DOWNSPOUT INTO CAP COVER PROPOSED GROUND FOUNDATION WALL 90o BEND 8" N-12 PIPE CONNECT TO 15" STORM SEWER W/WYE OWNER: BACK NINE PROPERTIES LLC. STACY LYMAN 23033 K AVENUE GRUNDY CENTER, IOWA 50638 (319)231-2995 dslyman@me.com IF VALVES ARE IN PAVEMENT CONSTRUCT FLUSH TO TOP OF SLAB DE T A I L S S H E E T C6.2 DRAWING DATE: PROJECT: SHEET: NO T F O R C O N S T R U C T I O N LO T 1 , J A M E S P O I N T E P L A T 3 WA U K E E , I O W A 220006 6-15-2022 7-19-2022 OR C A C O N S U L T I N G 35 1 2 R I C H L A N D R O A D VA N M E T E R , I O W A 5 0 2 6 1 mi c h a e l @ o r c a c o n s u l t i n g . b i z | ( 5 1 5 ) 7 7 8 - 6 6 0 9 FIRST CITY SUBMITTAL SECOND CITY SUBMITTAL PRELIMINARY BID SET7-14-2022 8-16-2022 THIRD CITY SUBMITTAL 9-9-2022 FOUTH CITY SUBMITTAL OWNER: BACK NINE PROPERTIES LLC. STACY LYMAN 23033 K AVENUE GRUNDY CENTER, IOWA 50638 (319)231-2995 dslyman@me.com PROPOSED BUILDING 1 22,500 SF MOE = 1024.00 FFE = 1027.00 60 . 0 0 ' 375.00'W 6" W6" SAN 6" SA N 6" SA N 6" CO W6"CO D CO CO CO TOP OF FOUNDATION = 1029.00 TRANSITION TOP OF FOUNDATION 1029.00 TO 1027.75 TRANSITION TOP OF FOUNDATION 102.75 TO 1027.00 TOP OF FOUNDATION = 1027.75 TRANSITION TOP OF FOUNDATION 1029.00 TO 1027.75 PROPOSED BUILDING 2 24,300 SF MOE = 1024.00 FFE = 1026.3560 . 0 0 ' 405.00' W SO SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF S F SF SF SF SF SF SF SF SF SF SF SF SF ROCKED CONSTRUCTION ENTRANCE MINIMUM 25' WIDE & 50' LONG 3" ROCK WITH MINIMUM 6" DEPTH OUTHOUSE, DUMPSTER, CONTAMINANT CONTAINMENT DEVICE & CONCRETE WASHOUT SF SF BELOW GRADE SILT BASKET FOR INTAKE. SILT FENCE (TYP.) SILT FENCE (TYP.) SF SFSFSF SF SF SF SF SF TOPSOIL STOCKPILE SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF BELOW GRADE SILT BASKET FOR INTAKE. SF SF SF SF AT GRADE SILT FABRIC FOR INTAKE UNDER CASTING. PROTECT HYDRANT PROTECT HYDRANT PROTECT UTILITY POLE PROTECT UTILITY POLE OHD (TYP) REF. ARCH AT GRADE SILT FABRIC FOR INTAKE UNDER CASTING. CO CO INSTALL CLASS D RIP RAP DO NOT DEGRADE DETENTION GEOMETRY SEE SWMP FOR LENGTH AND DEPTH OF RIP RAP, L = 10' SHORE TO ELEVATION = 1013.50) H YD DOWNSPOUT (TYP) DOWNSPOUT (TYP) MANDOOR TO FIRE RISER ROOM MANDOOR TO FIRE RISER ROOM CO MAN DOOR (TYP) REF. ARCH DOWNSPOUT (TYP) (SEE DETAIL C6.1) OHD (TYP) REF. ARCH MAN DOOR (TYP) REF. ARCH DOWNSPOUT (TYP) (SEE DETAIL C6.1) SF SF BELOW GRADE SILT BASKET FOR INTAKE. 1020 1020 1020 10 1 9 10191019 1023 1023 1024 10241024 1025 1025 1025 1027 1026 1028 1026 1027 1028 1029 1026 1027 1027 1027 1028 1028 NW GETTYSBURG LANE (CONCRETE PUBLIC ROAD - 29' B/B - 60' R.O.W.) (1 0 ' P U B L I C U T I L I T Y EA S E M E N T B K . 2 0 2 1 P G . 2 4 5 ) LOT 1 SA N SA N D WV WVHY D WV WV H Y D FO F/O WV WVHY D WV WV WV CO ST 48 " ST 48 " ST 48 " ST 48 " ST 48 " ST ST SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8" G G G G G G G G G G W8"W 8"W 8"W 8"W8"W8"W8" W8"W8" W 6" W6" U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E (4 0 ' L A N D S C A P E B U F F E R EA S E M E N T B K . 2 0 2 1 P G . 2 4 7 ) (20' PRIVATE STORM SEWER AND OVERLAND FLOWAGE EAESMENT BK. 2021 PG. 251) (20' PRIVATE STORM SEWER AND OVERLAND 15 ' S A N I T A R Y S E W E R E A S E M E N T BK 2 0 2 1 P G 2 4 6 10 ' P U E BK . 2 0 2 1 P G 2 4 5 33' SANITARY SEWER EASEMENT 15' PUEBK 2021 PG 245 10 ' P U E BK . 2 0 2 1 P G . 2 4 5 STORM WATER MANAGEMENT FACILITY EASEMENT BK. 2021 PG 252 SITE SW P P P C7.1 DRAWING DATE: PROJECT: SHEET: NO T F O R C O N S T R U C T I O N LO T 1 , J A M E S P O I N T E P L A T 3 WA U K E E , I O W A 220006 6-15-2022 7-19-2022 OR C A C O N S U L T I N G 35 1 2 R I C H L A N D R O A D VA N M E T E R , I O W A 5 0 2 6 1 mi c h a e l @ o r c a c o n s u l t i n g . b i z | ( 5 1 5 ) 7 7 8 - 6 6 0 9 FIRST CITY SUBMITTAL SECOND CITY SUBMITTAL PRELIMINARY BID SET7-14-2022 8-16-2022 THIRD CITY SUBMITTAL 9-9-2022 FOUTH CITY SUBMITTAL GRAPHIC SCALE 040 20 40 80 PROPERTY DESCRIPTION: LOT 1 JAMES POINTE PLAT 3, AN OFFICIAL PLAT, NOW INCLUDED IN AND FORMING A PART OF THE CITY OF WAUKEE, DALLAS COUNTY, IOWA. SUBJECT TO AND TOGETHER WITH ANY AND ALL EASEMENTS AND RESTRICTIONS OF RECORD. ADDRESS: 1575 NW GETTYSBURG LANE WAUKEE, IOWA 50263 OWNER: BACK NINE PROPERTIES LLC. STACY LYMAN 23033 K AVENUE GRUNDY CENTER, IOWA 50638 (319)231-2995 dslyman@me.com SITE AREA: 2.62 ACRES BENCHMARK: SEE SHEET C0.1 SITE SURVEY STORM WATER POLLUTION PREVENTION PLAN VICINITY MAP SCALE: NONE IOWAONE CALL 1-800-292-8989 www.iowaonecall.com 811 Know what's below. Call before you dig. UTILITY NOTE THE LOCATION OF THE UTILITIES INDICATED ON THE PLANS ARE TAKEN FROM EXISTING PUBLIC RECORDS AND/OR SURVEY OF ONE CALL FIELD MARKUPS, AND ARE APPROXIMATE LOCATIONS. THE EXACT LOCATIONS OF ALL UTILITIES MUST BE ASCERTAINED IN THE FIELD. IT SHALL BE THE DUTY OF THE CONTRACTOR TO DETERMINE WHETHER ANY ADDITIONAL FACILITIES OTHER THAN THOSE SHOWN ON THE PLANS MAY BE PRESENT. EROSION CONTROL NOTES: 1.SEE SUPPLEMENTAL DETAIL STORM WATER POLLUTION PLAN NARRATIVE FOR ALL EROSION CONTROL MEASURES, ADDITIONAL DETAILS AND NOTE. ADDITIONAL NOTES AND MEASURES IN NARRATIVE SHALL BE CONSIDERED INCIDENTAL AND SHALL BE INCLUDED IN THE ORIGINAL BID. 2.SWPPP PLAN AND NARRATIVE ARE CONSIDERED A LIVING DOCUMENT AND WILL NEED PERIODIC UPDATES AND ADJUSTMENTS AS NECESSARY DEPENDING ON SITE CONDITIONS TO ASSURE COMPLIANCE WITH NPDES GENERAL PERMIT NO. 2. IT IS THE CONTRACTOR'S RESPONSIBILITY TO UPDATE THE SWPPP AND IMPLEMENT ANY AND ALL MEASURES NECESSARY TO COMPLY WITH SAID PERMIT NO. 2. 3.INSTALL PERIMETER SILT FENCE AS SHOWN ON PLANS PRIOR TO CONSTRUCTION. 4.INSTALL INTAKE PROTECTION WITH SILT FENCE IMMEDIATELY AFTER STORM SEWER CONSTRUCTION. 5.INSTALL FINISHED PAVING INLET PROTECTION IMMEDIATELY AFTER PAVING IS COMPLETED AROUND INTAKE. 6.OTHER EROSION CONTROL TYPES MAY NOT BE SUBSTITUTED FOR SILT FENCE. 7.CONTRACTOR SHALL BE RESPONSIBLE FOR SUPPLYING A CONCRETE WASHOUT IN ACCORDANCE WITH SUDAS SPEC. 11,050 DURING ALL CONCRETE WORK. 8.CONTRACTOR SHALL BE RESPONSIBLE FOR SUPPLYING TEMPORARY RESTROOM FACILITIES. SANITARY WASTE SHALL BE DISPOSED OF PER ALL FEDERAL, STATE AND LOCAL REGULATIONS. 9.CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING ALL TOPSOIL REQUIREMENTS OF NPDES GENERAL PERMIT NO. 2 ARE MET. EROSION CONTROL REMOVAL NOTES: 1.AFTER FINAL STABILIZATION HAS OCCURED, AS DEFINED IN NPDES GENERAL PERMIT NO. 2, CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL TEMPORARY EROSION CONTROL DEVICES INCLUDING, BUT NOT LIMITED TO: SILT FENCE, INLET PROTECTION, AND TEMPORARY STANDPIPES. NOT TO SCALE SITE ENTRANCE DETAIL TEMP. ROCK ENTRANCE (PLAN VIEW) (PROFILE VIEW) TEMP. ROCK ENTRANCE 3" CLEAN LIMESTONE PLACE ROCK ON FABRIC STABILIZED ENTRANCE SHALL BE AT LEAST 50' LONG AND EXTEND TO THE PUBLIC ROADWAY. STAGING AREA TO BE CONSTRUCTED IN ACORDANCE TO THIS DETAIL. 5' - 0 " M I N . GROUND LINE ENGINEERING FABRIC FLOW 2 1' ABOVE GROUND LINE VARIABLE 10' MAX.5' MAX.5' MAX.10' MAX. 1' ABOVE GROUND LINE SECURE TOP OF ENGINEERING FABRIC ENGINEERING FABRIC TO BE PLACED TO BOTTOM OF TRENCH. 1 2 ENGINEERING FABRIC GROUND LINE TRENCH BOTTOM TRENCH BOTTOM 1 1 1 LINE GROUND 1 MIN. 4" EXCESS FABRIC COMPACTED BACKFILL 12 " MI N . DETAIL OF SILT FENCE AT DITCH OR SWALE DETAIL OF SILT FENCE 8' SPACING TO TOP OF STEEL POST. SEE DETAIL OF ATTACHMENT TO POST. VERTICAL CUT WIRE CORD CORD CORD WIRE POST FABRIC FABRIC BACK VIEW OF FABRIC BACK VIEW ATTACHMENT TO POST 3 4 NOTES : 3 MAKE VERTICAL CUT IN TOP OF FABRIC. PULL OUT AND TWIST CORD. 4 LOOP CORD AROUND POST FORMING A LOOP. PULL WIRE THROUGH FOLD AREA OF FABRIC AND SECURE AROUND POST. 'T' STEEL FENCE POST NORMAL FORESLOPE 2" RISE IN FENCE 31" MIN. NORMAL BACKSLOPE 31 " M I N . 6" TRENCH DEPTH FOR NORMAL INSTALLATION (MIN.) 12" TRENCH DEPTH FOR DITCH INSTALLATION NOT TO SCALE (SECTION VIEW) (PROFILE VIEW) SILT FENCE DETAILS NOT TO SCALE INLET 5'-0" 5'-0" 'T' FENCE POST, 5' MIN. NOTES: 1. SECURE TOP OF FABRIC TO POSTS, USING CABLE TIES OR WIRE. 2. FABRIC TO BE BURIED 12", AND FOLDED ALONG BOTTOM. 3. STEEL POSTS TO BE EMBEDDED 28". (PLAN VIEW) DROP INLET BASKET PROTECTION SILT FENCE FABRIC IF APPLICABLE INLET PROTECTION DETAIL NOT TO SCALE NOTES: 1. 1 C.Y. CONCRETE BAG SHALL BE REQUIRED AT ANY LOCATION WHERE CONCRETE IS USED. 2. CONCRETE WASHOUT DUMPSTER W/ HEAVY DUTY LINER IS AN ACCEPTIBLE ALTERNATIVE (PLAN VIEW) 1 C.Y. CONCRETE WASH-OUT BAG 'T' FENCE POST 5' MIN CONCRETE WASH-OUT BAG DETAIL (PROFILE VIEW) 1 C.Y. CONCRETE WASH-OUT BAG LIMITS OF DISTURBANCE NOTES: 1.CONSTRUCTION ACTIVITIES WILL DESTABILIZE THE ENTIRE SITE EXCEPT THE AREA IN THE EXISTING OVERLAND FLOW EASEMENT ON THE WEST EXTENT OF THE PROJECT. THERE WILL ALSO BE CONSTRUCTION ACTIVITIES IN THE ROW ABUTTING THE PROJECT AREA. TOTAL AREA OF DISTURBANCE IS 2.61 ACRES. STORM WATER DISCHARGE NOTES: 1.ULTIMATE DISCHARGE OF STORM WATER IS TO BE THE REGIONAL DETENTION PROVIDED TO THE NORTH OF THE PROJECT AREA. SEE CITY APPROVED SWMP FOR REGIONAL DETENTION FOR ULTIMATE DISCHARGE TO NAMED WATER BODY. SWPPP BMP SCHEDULE: 1.INTAKE PROTECTION DEVICES = 6EA 2.SILT FENCE (APPROX.)= 1,850LF 3.CONCRETE WASHOUT PIT = 1EA 4.TEMPORARY RESTROOM = 1EA 5.RIP/RAP = 10' OF LENGTH, 1.5' DEPTH NOTE: BMP SCHEDULE IS APPROXIMATE AND TO BE UPDATED AT LEAST EVERY 7 DAYS PER IDNR NPDES GENERAL PERMIT #2 AND WAUKEE COSESCO REGULATIONS. TEMPORARY STABILIZATION: 1.USE SUDAS TYPE-4 SEED MIX FOR TEMPORARY STABILIZATION IF REQUIRED BY THE GENERAL PERMIT #2 014 DAY RULE. AREA OF TEMP MIX TO BE DETERMINED BY LIVING SWPPP NARRATIVE DOCUMENT & WEEKLY INSPECTOR.. 35 0 1 1 0 4 t h S t r e e t De s M o i n e s , I o w a 5 0 3 2 2 - 3 8 2 5 Ph o n e : ( 5 1 5 ) 2 7 6 - 0 4 6 7 F a x : ( 5 1 5 ) 2 7 6 - 0 2 1 7 "P l a n n i n g Y o u r S u c c e s s f u l D e v e l o p m e n t " Bi s h o p E n g i n e e r i n g Ci v i l E n g i n e e r i n g & L a n d S u r v e y i n g E s t a b l i s h e d 1 9 5 9 JA M E S P O I N T E P L A T 3 DA L L A S C O U N T Y , I O W A FI N A L P L A T 220226 1 OF 2 JAMES POINTE PLAT 3 FINAL PLAT ZONING: ZONED: M-1 LIGHT INDUSTRIAL SETBACKS: FRONT YARD: 30 FEET; WHEN FRONTING ON THE RIGHT-OF-WAY OF A MAJOR THOROUGHFARE SHOWN ON THE OFFICIAL MAJOR STREET PLAN, THE FRONT YARD SHALL BE MEASURED FROM THE PROPOSED RIGHT-OF-WAY LINE. SIDE YARD: NONE REQUIRED EXCEPT WHEN ADJACENT TO AN "R" OR "C-1" DISTRICT OR STREET RIGHT-OF-WAY LINE, A SIDE YARD OF 25 FEET SHALL BE REQUIRED. REAR YARD: 30 FEET, UNLESS THE REAR LOT LINE ADJOINS A RAILROAD RIGHT-OF-WAY, IN WHICH CASE, NONE REQUIRED. SURVEY NOTES: THIS PLAT HAS AN ERROR OR CLOSURE OF LESS THAN 1.0 FEET IN 10,000.0 FEET. EACH LOT WITHIN THIS PLAT HAS AN ERROR OF CLOSURE OF LESS THAN 1.0 FEET IN 5,000.0 FEET. 1. ALL CORNERS HAVE BEEN PLACED WITH A 3/4 INCH IRON PIPE UNLESS NOTED OTHERWISE. ALL CORNERS PLACED HAVE A YELLOW PLASTIC IDENTIFICATION CAP NO. 14775. 2. PLAT IS TO COMBINE 2 LOTS INTO ONE LOT. NO GRADING OR UTILITY WORK IS PART OF THIS PROJECT. 3. BASIS OF BEARING OBTAINED FROM GPS OBSERVATIONS, DATUM = NAD 83, IOWA SOUTH. 4. 5' PUBLIC SIDEWALK IS TO BE CONSTRUCTED AT TIME OF SITE DEVELOPMENT. 5. LOTS MAY BE SUBJECT TO MINIMUM PROTECTION ELEVATIONS AND OTHER ELEVATION RESTRICTIONS NOT SHOWN ON THIS PLAT. REFER TO THE APPROVED PROJECT ENGINEERING DOCUMENTS FOR ANY ELEVATION RESTRICTIONS. 6. STORM WATER DETENTION IS PROVIDED IN LOT 30 OF JAMES POINTE PLAT 1 AS A REGIONAL DETENTION BASIN. PROPERTY DESCRIPTION: LOT 24 AND LOT 25 IN JAMES POINTE PLAT 1, AN OFFICIAL PLAT, WAUKEE, DALLAS COUNTY, IOWA. SUBJECT TO AND TOGETHER WITH ANY AND ALL EASEMENTS AND RESTRICTIONS OF RECORD. SAID TRACT CONTAINS 2.61 ACRES (113,949.87 SQUARE FEET) COPYRIGHT 2022 BISHOP ENGINEERING. THIS DOCUMENT AND THE INFORMATION CONTAINED MAY NOT BE REPRODUCED OR EXCERPTED WITHOUT THE EXPRESS WRITTEN PERMISSION OF BISHOP ENGINEERING. UNAUTHORIZED COPYING OR DISCLOSURE OF CONSTRUCTION USE ARE PROHIBITED BY COPYRIGHT LAW. FLOOD HAZARD CERTIFICATION: ACCORDING TO THE FIRM (FLOOD INSURANCE RATE MAP) ISSUED BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY (FEMA) ON FLOOD INSURANCE RATE MAP 19049C0335F, WITH AN EFFECTIVE DATE OF 12/7/2018, THIS SITE IS LOCATED IN A ZONE "X", AN AREA DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN. THIS CERTIFICATION IS BASED ON THE LATEST KNOWN MAP FOR THIS PARCEL. VICINITY MAP SCALE: 1' = 1000' SITE PRELIMINARY 1 AND 2 LOCATION: LOT 24 AND LOT 25 IN JAMES POINTE PLAT 1 OWNER: BACK NINE PROPERTIES, LLC 23033 K AVENUE, GRUNDY CENTER, IA 50638 (319) 231-2995 DEVELOPER: BACK NINE PROPERTIES, LLC STACEY LYMAN 23033 K AVENUE, GRUNDY CENTER, IA 50638 (319)231-2995 PREPARED FOR: MICHAEL WAHLERT PE ORCA CONSULTING LLC 3512 RICHLAND ROAD, VAN METER, IA 50261 (515)778-6609 PREPARED BY: LARRY HYLER PLS BISHOP ENGINEERING 3501 104TH ST URBANDALE, IA 50322 515-276-0467 INDEX LEGEND OW N E R : W A U K E E L A N D I N V E S T M E N T L L C ZO N E D : M - 1 ( L I G H T I N D U S T R I A L ) OWNER: REDWOOD WAUKEE HICKMAN ROAD IA P1, LLC ZONED: R-4 (ROW DWELLING & TOWNHOME DWELLING DISTRICT) OWNER: JAQUES H&D REAL ESTATE, LLC ZONED: M-1 (LIGHT INDUSTRIAL) OWNER: JAQUES H&D REAL ESTATE, LLC ZONED: M-1 (LIGHT INDUSTRIAL) (N 89°53'57" E 230')(N 89°53'57" E 225.82') (S 0 ° 0 6 ' 0 3 " E 2 5 0 ' ) (N 0 ° 0 6 ' 0 3 " W 2 5 0 ' ) (S 89°53'57" W 225.82')(S 89°53'57" W 230') (N 89°53'57" E 455.82') 40 ' L A N D S C A P E B U F F E R EA S E M E N T B K . 2 0 2 1 P G . 2 4 7 20' PRIVATE STORM SEWER AND OVERLAND FLOWAGE EAESMENT BK. 2021 PG. 251 NW GETTYSBURG LANE (CONCRETE PUBLIC ROAD - 60' R.O.W.) (6 0 ' R . O . W . ) OWNER: NADAREVIC INVESTMENTS V, LLC ZONED: M-1 (LIGHT INDUSTRIAL) 10 ' P U B L I C U T I L I T Y EA S E M E N T B K . 2 0 2 1 P G . 2 4 5 LOT 1 (113,949.87 SF - 2.61 ACRES) 1575 (S 0 0 ° 0 6 ' 0 3 " E 2 5 0 . 0 0 ' ) 35 0 1 1 0 4 t h S t r e e t De s M o i n e s , I o w a 5 0 3 2 2 - 3 8 2 5 Ph o n e : ( 5 1 5 ) 2 7 6 - 0 4 6 7 F a x : ( 5 1 5 ) 2 7 6 - 0 2 1 7 "P l a n n i n g Y o u r S u c c e s s f u l D e v e l o p m e n t " Bi s h o p E n g i n e e r i n g Ci v i l E n g i n e e r i n g & L a n d S u r v e y i n g E s t a b l i s h e d 1 9 5 9 JA M E S P O I N T E P L A T 3 DA L L A S C O U N T Y , I O W A FI N A L P L A T 220226 2 OF 2 ABBREVIATIONS: AC ACRES PUE PUBLIC UTILITY EASEMENT TYP TYPICAL N NORTH S SOUTH E EAST W WEST YPC YELLOW PLASTIC CAP MPE MINIMUM PROTECTION ELEVATION SF SQUARE FOOTAGE POB POINT OF BEGINNING POC POINT OF COMMENCEMENT PROPERTY CORNER - FOUND 1/2" IRON ROD WITH YELLOW PLASTIC CAP ID #15980 OR AS NOTED PROPERTY CORNER- PLACED 5/8" IRON ROD WITH YELLOW PLASTIC CAP ID #14775 CUT "X" IN PAVEMENT ADDRESS LEGEND: GRAPHIC SCALE 050 25 50 100 FIELD VERIFY ALL SITE DIMENSIONS AND BEARINGS Troy Plex Building 1 - Elevation Pella Building Systems, INC. 906 WEST 9TH ST. Pella, Iowa 50219 1-800-225-0491 or 1-641-628-9300 www.Pellabuilding.com CU S T O M P A N E L CU S T O M P A N E L Co l o r s - A s h G r a y : S t e e l Do o r s Un i t M i x Bu i l d i n g 1 15 - 2 5 x 6 0 ' 15 - 1 4 ' x 1 4 ' R o l l u p D o o r s - A c c e n t P a n e l s : S l a t e G r a y 16 - 3 ' x 7 ' W a l k D o o r s - B l a c k : T r i m , R o o f - W h i t e : R o l l u p D o o r s Ni c h i h a E n g i n e e r e d S t o n e P a n e l CU S T O M P A N E L CU S T O M P A N E L Ni c h i h a E n g i n e e r e d S t o n e P a n e l Br e a k d o w n o f M a t e r i a l s So u t h To t a l S q f t = 6 , 3 7 5 No r t h Ni c h i a E n g i n e e r e d St o n e P a n e l = 3 , 9 1 8 10 0 % P r i m a r y M a t e r i a l s To t a l S q f t = 6 , 3 7 5 Cu s t o m P a n e l S q f t = 3 , 5 8 8 Ea s t & W e s t 10 0 % P r i m a r y M a t e r i a l s To t a l S q f t = 2 , 1 0 0 Cu s t o m P a n e l S q f t = 2 , 1 0 0 Do o r s = 2 , 7 8 7 Cu s t o m P a n e l S q f t = 2 , 4 5 7 Bu i l d i n g M a t e r i a l s 4' x 2 ' W i n d o w s Ar c h i t e c t u r a l M e t a l P a n e l C o n c e a l e d F a s t e n e r En g i n e e r e d S t o n e P a n e l FIELD VERIFY ALL SITE DIMENSIONS AND BEARINGS Troy Plex Building 2 - Elevation Pella Building Systems, INC. 906 WEST 9TH ST. Pella, Iowa 50219 1-800-225-0491 or 1-641-628-9300 www.Pellabuilding.com CU S T O M P A N E L CU S T O M P A N E L CU S T O M P A N E L CU S T O M P A N E L Co l o r s - A s h G r a y : S t e e l Do o r s Un i t M i x Bu i l d i n g 2 19 - 2 0 x 5 0 ' 19 - 1 4 ' x 1 4 ' R o l l u p D o o r s - A c c e n t P a n e l s : S l a t e G r a y 1- 2 5 x 6 0 ' 20 - 3 ' x 7 W a l k D o o r s - B l a c k : T r i m , R o o f - W h i t e : R o l l u p D o o r s CU S T O M P A N E L CU S T O M P A N E L CU S T O M P A N E L CU S T O M P A N E L Br e a k d o w n o f M a t e r i a l s So u t h 10 0 % P r i m a r y M a t e r i a l s To t a l S q f t = 6 , 8 8 5 Cu s t o m P a n e l S q f t = 3 , 5 4 0 No r t h Do o r s l S q f t = 3 , 3 4 5 10 0 % P r i m a r y M a t e r i a l s To t a l S q f t = 6 , 8 8 5 Cu s t o m P a n e l S q f t = 6 , 4 7 7 Ea s t & W e s t 10 0 % P r i m a r y M a t e r i a l s To t a l S q f t = 2 , 1 0 0 Cu s t o m P a n e l S q f t = 2 , 1 0 0 Bu i l d i n g M a t e r i a l s 4' x 2 ' W i n d o w s Ar c h i t e c t u r a l M e t a l P a n e l C o n c e a l e d F a s t e n e r En g i n e e r e d S t o n e P a n e l Ni c h i a E n g i n e e r e d St o n e P a n e l = 4 0 8