Loading...
HomeMy WebLinkAbout2022-11-07 J10A-D Williams Pointe Commercial Plat 1_Preliminary Plat, Final Plat, CDs, Site PlanAGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: November 7, 2022 AGENDA ITEM:Consideration of approval of resolutions approving a preliminary plat, final plat, site plan and construction drawings for Williams Pointe Commercial Plat 1 / Gerber Collision & Glass FORMAT:Resolution SYNOPSIS INCLUDING PRO & CON: The applicant is requesting approval of a preliminary plat, final plat, site plan and sanitary sewer construction drawings for a 2.18-acre development for an automotive collision and repair development located north of University Avenue and east of SE Alice’s Road The project involves the construction of an automotive collision and repair center that will be approximately 14,220-square feet and one-story. The site will be accessed from the shared drive off SE Alice’s Road south of the existing gas station. The elevations of the buildings will be constructed of Brick, Concrete Block, EIFS and Windows. A trash enclosure will be located near the southeast corner of the site and a monument sign is proposed near the northwest edge of the site. The final plat includes two lots; Lot 1 and Outlot X. Lot 1 is 2.18-acres in area and will include the automotive repair center. Outlot X will be developed at a later date and will be platted at that time. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning Commission reviewed the site plan request at their meeting on September 13, 2022 and recommended approval: Approval of a Preliminary Plat for Williams Pointe Commercial Plat 1 Approval of a Final Plat for Williams Pointe Commercial Plat 1 Approval of a Site Plan for Gerber Collision & Glass (950 SE Brick Drive) City Planner, Bill Mettee, introduced the request for approval of a preliminary plat, final plat, and site plan for a automotive repair and body shop as submitted by the applicant, Gerber Collision & Glass. The property is generally located east of SE Alice’s Road and north of SE University Avenue, containing approximately 2.18 acres. Mr. Mettee advised that the project involves the construction of a single story building approximately 14,221 square feet in area. A trash enclosure is located at the southeast corner of the property and a monument sign is proposed at the northwest corner of the site. Access to the site will be from SE Alice’s Road using the shared private road with KwikTrip to the north. The private road will be extended east to access Gerber Collision and also extend south for future access for development that will occur within Outlot “X”. Public utilities will serve the site, and stormwater management is J10A-D accommodated for by a detention basin located on the west end of the property. All parking, landscaping, open space, and elevation requirements have been met at this time. Staff would recommend approval of the preliminary plat, final plat, and site plan for Williams Pointe Commercial Plat 1/ Gerber Collision subject to remaining staff comments and review of the legal documents. Commissioner Hoifeldt questioned why the building had a SE Brick address but no access on to SE Brick Drive. Community Development Director, Andy Kass, advised that eventually access to SE Brick Drive will be provided, but that the addressing was reviewed by emergency services for accuracy. Mr. Kass also advised that it is not uncommon for this area, as some other buildings face SE University Avenue, but do not front or have direct access off of SE University Avenue. Commissioner Streit Moved to approve a Preliminary Plat for Williams Pointe Commercial Plat 1. The motion was seconded by Commissioner Tessau. Ayes: Koelker, Hoifeldt, Streit, and Broderick. Recused: Tessau. Nays: none. Motion Carried. Commissioner Streit Moved to approve a Preliminary Plat for Williams Pointe Commercial Plat 1. The motion was seconded by Commissioner Hoifeldt. Ayes: Koelker, Hoifeldt, Streit, and Broderick. Recused: Tessau. Nays: none. Motion Carried. Commissioner Streit Moved to approve a Site Plan for Gerber Collision & Glass (950 SE Brick Drive). The motion was seconded by Commissioner Koelker. Ayes: Koelker, Hoifeldt, Streit, and Broderick. Recused: Tessau. Nays: none. Motion Carried. STAFF REVIEW AND COMMENT: Staff recommends approval of the preliminary plat, final plat, site plan and sanitary sewer construction drawings subject to remaining staff comments and review of the legal documents. RECOMMENDATION: Approve the resolutions. ATTACHMENTS: I. Proposed Resolutions II. Staff Report III. Site Plan IV Preliminary Plat V. Final Plat VI. Construction Drawings VII. Building Elevations PREPARED BY:Bill Mettee, Planner REVIEWED BY: PUBLIC NOTICE INFORMATION – NAME OF PUBLICATION: DATE OF PUBLICATION: THE CITY OF WAUKEE, IOWA RESOLUTION 2022- APPROVING THE PRELIMINARY PLAT FOR WILLIAMS POINTE COMMERCIAL PLAT 1 IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission reviewed and recommended approval of a Preliminary Plat for Williams Pointe Commercial Plat 1 on September 13, 2022; AND, WHEREAS, the Preliminary Plat for Williams Pointe Commercial Plat 1 is in general conformance with section §176 - Subdivision Regulations of the Waukee Municipal Code. NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this the 7th day of November, 2022 that the Preliminary Plat for Williams Pointe Commercial Plat 1 be approved subject to remaining staff comments. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Anna Bergman Pierce R. Charles Bottenberg Chris Crone Larry R. Lyon Ben Sinclair THE CITY OF WAUKEE, IOWA RESOLUTION 2022- APPROVING THE FINAL PLAT FOR WILLIAMS POINTE COMMERCIAL PLAT 1 IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, Coralville AAP, LLC, has requested final plat approval of Williams Pointe Commercial Plat 1 (the “Plat”); AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Plat on September 13, 2022, subject to remaining staff comments and review of the legal documents; AND, WHEREAS, the Final Plat for Williams Pointe Commercial Plat 1 and the documents relating thereto will comply with section §176 – Subdivision Regulations of the Waukee Municipal Code. NOW, THEREFORE, BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 7th day of November, 2022, that the Final Plat for Williams Pointe Commercial Plat 1 be and the same is hereby accepted and approved by the City Council of the City of Waukee. BE IT FURTHER RESOLVED that the City of Waukee does hereby accept the following easements and documents to be filed with the Plat: 1.Gas Main Easement; 2.Public Ingress – Egress Easement; 3.Public Landscape Buffer Easement; 4.Public Overland Flowage Easement; 5.Private Storm Sewer and Surface Water Flowage Easement; 6.Public Utility Easement; and 7.Public Sanitary Sewer Easement ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Anna Bergman Pierce R. Charles Bottenberg Chris Crone Larry R. Lyon Ben Sinclair THE CITY OF WAUKEE, IOWA RESOLUTION 2022- APPROVING THE SITE PLAN FOR GERBER COLLISION & GLASS IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Site Plan for Gerber Collision & Glass, subject to remaining staff comments on September 13, 2022; AND, WHEREAS, the Site Plan for Gerber Collision & Glass is in general conformance with §160 – Site and Building Development Standards Ordinance of the Waukee Municipal Code; AND, WHEREAS, the Site Plan for Gerber Collision & Glass is in general conformance with §161 – Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND, NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 7th day of November, 2022 that the Site Plan for Gerber Collision & Glass is approved. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Anna Bergman Pierce R. Charles Bottenberg Chris Crone Larry R. Lyon Ben Sinclair THE CITY OF WAUKEE, IOWA RESOLUTION 2022- APPROVING THE CONSTRUCTION DRAWINGS FOR WILLIAMS POINTE COMMERCIAL PLAT 1 IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, construction drawings have been submitted to the City for Williams Pointe Commercial Plat 1; AND, WHEREAS, the construction drawings have been reviewed by the City Engineer and City staff, and are found to be in general conformance with section §177 – Subdivision Regulations – Design Standards of the Waukee Municipal Code. NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 7th day of November, 2022 that the Construction Drawings for Williams Pointe Commercial Plat 1 be approved. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Anna Bergman Pierce R. Charles Bottenberg Chris Crone Larry R. Lyon Ben Sinclair PLANNING AND ZONING COMMISSION STAFF REPORT PROJECT: Williams Pointe Commercial Plat 1 – Preliminary Plat and Final Plat / Gerber Collision – Site Plan PREPARED BY: Bill Mettee – Planner REPORT DATE: September 9, 2022 MEETING DATE: September 13, 2022 GENERAL INFORMATION Owner / Applicant: Owner – Coralville AAP, LLC / Applicant – Gerber Collision & Glass Project Manager: Trent Smith, PE, McClure Engineering / Amanda Johnson, Anderson Engineering Request: The applicant is requesting approval of a preliminary plat, final plat and site plan for an automotive repair and body shop. Location and Size: Property is located east of SE Alice’s Road and north of SE University Avenue, containing approximately 2.18 acres. Property Address: 950 SE Brick Drive AREA MAP ABOVE: Aerial of subject property (outlined in RED) in relation to the surrounding area. September 9, 2022 2 of 3 LAND USES AND ZONING Location Existing Land Use Comprehensive Plan Current Zoning Property in Question Vacant – Undeveloped Community Commercial C-1 (Community and Highway Service Commercial District) North Apartments at Autumn Ridge High-Density Residential R-3 / PD-1 (Multi-Family Residential / Planned Development Overlay District) South Vacant – Undeveloped Community Commercial C-1 (Community and Highway Service Commercial District) East Williams Pointe Condominiums High-Density Residential R-3 / PD-1 (Multi-Family Residential / Planned Development Overlay District) West Vacant - Undeveloped Community Commercial C-1 (Community and Highway Service Commercial District) PROJECT DESCRIPTION The project involves the construction of a building that is proposed to be approximately 14,221 square feet in area. A trash enclosure is shown in the southeast corner of the property and a monument sign is proposed near the northwest corner of the site. ACCESS AND PARKING Access to this site will be from SE Alice’s Road using the shared private road with Kwik Trip to the north. The private road will be extended east to access Gerber Collision and also extended south for future access for development that will occur within Outlot “X.” An access easement is proposed to allow access to and from adjacent sites. A total of 44 parking spaces are required for this site and they are providing a total of 49 parking spaces including two handicap accessible spaces. SIDEWALKS/TRAILS A five-foot wide sidewalk will be installed along SE Brick Drive the length of the proposed plat. UTILITIES All utilities exist in the immediate vicinity to this site and will be extended as needed to service the building. Storm water detention will be provided with the detention basin located on the west end of the property. LANDSCAPING & OPEN SPACE A minimum of 20% of the project area is required to be open space. The total amount of open space proposed is 41%. The applicant has provided the required number of plantings per the landscaping ordinance, including landscape buffers along the north and east property lines. September 9, 2022 3 of 3 ELEVATIONS The elevations of the building are proposed to be constructed primarily of brick and stone, concrete blocks and EIFS with several overhead doors and storefront glazing. The trash enclosure is proposed to be constructed of brick similar in style and color to the primary structure. MISCELLANEOUS The applicant has submitted a photometric plan and associated light fixture cut sheets. The lighting plan meets the lighting requirements of the Site Plan Ordinance. STAFF RECOMMENDATION Staff recommends approval of the preliminary plat, final plat and site plan for Williams Pointe Commercial Plat 1 / Gerber Collision subject to remaining staff comments and review of the legal documents SE UNIVERSITY AVE. SE A L I C E ' S R D . SE B R I C K D R . BUILDING 01PP-01 COVER LETTER N: \ P r o j e c t s \ W A K 2 0 2 1 8 0 3 8 \ D w g s \ P l a n s \ P r e l i m i n a r y P l a t \ W i l l i a m s P o i n t e P r e p l a t . d w g 10 / 2 6 / 2 0 2 2 8 : 2 8 A M MCCLURE ENGINEERING 1360 NW 121ST STREET CLIVE, IOWA 50325 (515) 964-1229 TSMITH@MECRESULTS.COM ATTN: TRENT SMITH WARRANTY DEED FILED IN BOOK 2017 PAGE 15323 AND BOOK 2017 PAGE 15321: PARCEL "AA" OF THE SURVEY OF PART LOT 2 WILLIAMS POINTE PLAT 7, AN OFFICIAL PLAT LOCATED IN WAUKEE, DALLAS COUNTY, IOWA AS RECORDED IN BOOK 2014, PAGE 11668, EXCEPT LAND DEEDED TO THE CITY OF WAUKEE AS RECORDED IN BOOK 2017, PAGE 4500. SUBJECT TO EASEMENTS, RESTRICTIONS AND COVENANTS OF RECORD. AND LOT 2 IN WILLIAMS POINTE PLAT 9, AN OFFICAL PLAT, WAUKEE, DALLAS COUNTY, IOWA, EXCEPT WILLIAMS POINTE PLAT 5 AND EXCEPT LAND DEEDED TO THE CITY OF WAUKEE AS RECORDED IN BOOK 2017, PAGE 4495. SUBJECT TO EASEMENTS, RESTRICTIONS AND COVENANTS OF RECORD. TOTAL ACRES: 9.03 AC ALL CONSTRUCTION SHALL BE COMPLETED IN ACCORDANCE WITH THE 2022 IOWA STATEWIDE URBAN DESIGN STANDARD AND SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND THE 2020 WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS C-1 COMMUNITY AND HIGHWAY SERVICE COMMERCIAL DISTRICT FRONT BUILDING SETBACK - 30 FEET REAR BUILDING SETBACK - 30 FEET SIDE BUILDING SETBACK - NO MINIMUM, EXCEPT WHEN ADJACENT TO ANY R DISTRICT, THE MINIMUM SIDE YARD SETBACK SHALL BE 30 FEET. MAXIMUM HEIGHT - NO MINIMUM EXCEPT WHEN ADJACENT TO AN R-1, R-2 OR R-4 DISTRICT, THE MAXIMUM SHALL BE 2 STORIES OR 40 FEET 1 STORY OR 14 FEET FOR ACCESSORY BUILDING VICINITY MAP GAS - WAUKEE PUBLIC WORKS DEPARTMENT ELECTRIC - MID-AMERICAN ENERGY CO. WATER - CITY OF WAUKEE PUBLIC WORKS DEPARTMENT SEWER - CITY OF WAUKEE PUBLIC WORKS DEPARTMENT DSDH.WAUKEE, LLC 9251 WILLOW LANE FREMONT, WI 54940 920.428.9028 DAVE@HERBECKDEVELOPMENT.COM ATTN: DAVE HERBECK NORTH 1000 GRAPHIC SCALE 200 NORTH DRAWING NO. CHECKED BY ENGINEER SHEET NO. FIELD BOOK NO. DRAWN BY REVISIONS NOTICE: McClure Engineering Company waives any and all responsibility and liability for problems which arise from failure to follow these Plans, Specifications, and the engineering intent they convey, or for problems which arise from failure to obtain and/or follow the engineers guidance with respect to any errors, omissions, inconsistencies, ambiguities, or conflicts which are alleged. COPYRIGHT: Copyright and property rights in these documents are expressly reserved by McClure Engineering Company. No reproductions, changes, or copies in any manner shall be made without obtaining prior written consent from McClure Engineering Company. 1360 NW 121ST. Street Clive, Iowa 50325 515-964-1229 fax 515-964-2370 making lives better WILLIAMS POINTE COMMERCIAL PLAT 1 PRELIMINARY PLAT WAUKEE, IOWA 20218038-000 MAY 2022 T SMITH T SMITH -- . . . . . WILLIAMS POINTE COMMERCIAL PLAT 1 PRELIMINARY PLAT WAUKEE, IA 04 Sheet List Table Sheet Number Sheet Title Sheet Description 01 PP-01 COVER LETTER 02 PP-02 EXISTING CONDITIONS 03 PP-03 GENERAL LAYOUT 04 PP-04 EROSION & SEDIMENT CONTROL PLAN LOT 1 2.18 AC OUTLOT X 6.85 AC SE B R I C K D R . SE A L I C E ' S R D . SE UNIVERSITY AVE.SE UNIVERSITY AVE. SUBMITTAL DATE DESCRIPTION 1 5/10/2022 CITY SUBMITTAL #1 2 5/26/2022 CITY SUBMITTAL #2 3 6/21/2022 CITY SUBMITTAL #3 4 8/2/2022 CITY SUBMITTAL #4 5 9/6/2022 CITY SUBMITTAL #5 6 9/29/2022 CITY SUBMITTAL #6 7 10/17/2022 CITY SUBMITTAL #7 8 10/26/2022 CITY SUBMITTAL #8 I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF IOWA. TRENT LUNDY SMITH, PE NO. 26452 DATE: MY LICENSE RENEWAL DATE IS DECEMBER 31, 2022 PAGES OR SHEETS COVERED BY THIS SEAL: SE A L I C E ' S R D . SE B R I C K D R . N0 0 ° 1 3 ' 0 8 " E 5 6 6 . 9 7 ' ( M ) N0 0 ° 2 1 ' 1 9 " E 5 6 6 . 9 9 ' ( R ) S89°46'47"E 364.16'(M) S89°41'07"E 364.16'(R) L=153.73'(M&R) R=500.00'( M&R) ∆=17°36'58"(M&R) CHD=S80°58'18"E(M) CHD=S80°52'38"E(R) CHD L=153.12'(M&R) S72° 0 9 ' 4 9 " E 2 3 8 . 8 6 ' ( M ) S72° 0 4 ' 0 9 " E 2 3 8 . 8 3 ' ( R ) L=393.47'(M) L=393.47'(R) R=1285.00'(M&R) ∆=17°32'39"(M) ∆=17°32'39"(R) CHD=S9°03'18"W(M) CHD L=391.94'(M) S0 0 ° 1 6 ' 5 9 " W 9 4 . 6 0 ' ( M ) S0 0 ° 2 2 ' 4 4 " W 9 4 . 4 5 ' ( R ) N89°56'22"W 555.79'(M) N89°50'37"W 555.79'(R) L=66.50'(M) 66.51'(R) R=350.00'(M&R) ∆=10°53'13"(M&R) CHD=N84°29'46"W(M) CHD=N84°24'01"W(R) CHD L=66.40'(M) 66.41'(R) L=61.29'(M&R) R=350.00'(M&R) ∆=10°02'00"(M) ∆=10°02'01"(R) CHD=N84°04'10"W(M) CHD L=61.21'(M) STOP MANHOLE: 1054.05 15" RCP FL OUT N: 1047.85 15" RCP FL IN S: 1047.85 MANHOLE: 1055.02 15" RCP FL OUT N: 1049.27 15" RCP FL IN E: 1049.34 GUTTER: 1045.24 8" CMP FL IN N: 1043.46 24" RCP FL IN N: 1042.34 8" CMP FL IN E: 1042.34 24" RCP FL OUT S: 1042.3 MANHOLE=1046.22 30" RCP FL OUT SSW=1041.28 GUTTER: 1044.67 15" RCP FL OUT W: 1041.09 8" CMP FL IN E: 1041.97 8" CMP FL IN E: 1041.97 GUTTER: 1043.21 15" RCP FL OUT W: 1039.53 8" CMP FL IN E: 1040.66 MANHOLE: 1052.22 PIPE NOT VISIBLE BOTTOM OF WELL=10421.08 8" PVC FL OUT W: 1040.43 MANHOLE: 1048.57 8" PVC FL IN N: 1037.08 8" PVC FL IN E : 1037.08 8" PVC FL OUT S: 1036.98 FES 24 FL = 1043.41 BUILDING MANHOLE: 1048.92 18" RCP FL OUT SW: 1045.27 18" RCP FL IN E: 1045.29 MANHOLE: 1050.54 18" RCP FL OUT W: 1046.95 18" RCP FL IN SE: 1046.98 MANHOLE: 1048.96 24" RCP FL OUT W: 1043.67 24" RCP FL IN E: 1043.75 GUTTER: 1048.94 BOTTOM WELL: 1045.79 MANHOLE: 1051.29 15" RCP FL OUT SW: 1047.79 GUTTER: 1050.90 15" RCP FL IN NE: 1047.20MANHOLE: 1051.41 18" RCP FL OUT NW: 1047.16 GUTTER: 1048.92 24" RCP FL OUT NW: 1044.33 18" RCP FL IN NE: 1044.51 MANHOLE=1046.99 30" RCP FL IN NNE=1041.26 30" RCP FL OUT S=1041.24 MANHOLE: 1055.58 TOP 4" PIPE W: 1050.62 TOP 4" PIPE E: 1050.58 BOTTOM OF WELL: 1050.12 MANHOLE: 1055.38 BOTTOM OF WELL: 1051.73 TWIN 4" PIPES, CAPPED MANHOLE: 1047.33 BOTTOM OF WELL: 1044.23 TWIN 4" PIPES, CAPPED 12" FES STORM SEWER AND OVERLAND FLOWAGE EASEMENT BOOK 2006 PAGE 5703, BOOK 2006 PAGE 5706, BOOK 2006 PAGE 5707 70.00 ROW 31.00 B-B 25.00 B-B 130.16 ROW PARCEL ID: 1235302005 PARCEL ID: 1235351006 TEMPORARY STORM SEWER AND OVERLAND FLOWAGE EASEMENT BOOK 2004, PAGE 16161 50.00' ACCESS EASEMENT BOOK 2017 PAGE 3887 30.00' OVERLAND FLOWAGE EASEMENT BOOK 2004, PAGE 16172 BOOK 2004, PAGE 16177 10.00' PUE BOOK 2004, PAGE 16172 10.00' QWEST EASEMENT BOOK 2010 PAGE 17568 10.00' PUE, BOOK 2006 PAGE 5703, BOOK 2004 PAGE 16159, BOOK 2006 PAGE 5709 10.00' PUE BOOK 2017 PAGE 4498 25.00' INGRESS/EGRESS EASEMENT BOOK 2015 PAGE 5057 50.00' INGRESS/EGRESS, SANITARY SEWER AND WATER MAIN EASEMENT BOOK 2006, PAGE 5703 20.00' RIGHT OF WAY BOOK 2017 PAGE 4495, BOOK 2017 PAGE 3886 TEMPORARY CONSTRUCTION EASEMENT BOOK 2017, PAGE 4498 TEMPORARY CONSTRUCTION EASEMENT BOOK 2017 PAGE 4502 BOOK 2017, PAGE 4499 97.79 B-B 36.00' B-B STORM SEWER AND OVERLAND FLOWAGE EASEMENT BOOK 2006 PAGE 5703, BOOK 2006 PAGE 5706, BOOK 2006 PAGE 5707 TEMPORARY STORM SEWER AND OVERLAND FLOWAGE EASEMENT BOOK 2004, PAGE 16161 50.00' ACCESS EASEMENT BOOK 2017 PAGE 3887 30.00' OVERLAND FLOWAGE EASEMENT BOOK 2004, PAGE 16172 BOOK 2004, PAGE 16177 10.00' PUE BOOK 2004, PAGE 16172 10.00' QWEST EASEMENT BOOK 2010 PAGE 17568 10.00' PUE, BOOK 2006 PAGE 5703, BOOK 2004 PAGE 16159, BOOK 2006 PAGE 5709 10.00' PUE BOOK 2017 PAGE 4498 25.00' INGRESS/EGRESS EASEMENT BOOK 2015 PAGE 5057 50.00' INGRESS/EGRESS, SANITARY SEWER AND WATER MAIN EASEMENT BOOK 2006, PAGE 5703 20.00' RIGHT OF WAY BOOK 2017 PAGE 4495, BOOK 2017 PAGE 3886 TEMPORARY CONSTRUCTION EASEMENT BOOK 2017, PAGE 4498 TEMPORARY CONSTRUCTION EASEMENT BOOK 2017 PAGE 4502 BOOK 2017, PAGE 4499 36.00' B-B STORM SEWER AND OVERLAND FLOWAGE EASEMENT BOOK 2006 PAGE 5703, BOOK 2006 PAGE 5706, BOOK 2006 PAGE 5707 TEMPORARY STORM SEWER AND OVERLAND FLOWAGE EASEMENT BOOK 2004, PAGE 16161 50.00' ACCESS EASEMENT BOOK 2017 PAGE 3887 30.00' OVERLAND FLOWAGE EASEMENT BOOK 2004, PAGE 16172 BOOK 2004, PAGE 16177 10.00' PUE BOOK 2004, PAGE 16172 10.00' QWEST EASEMENT BOOK 2010 PAGE 17568 10.00' PUE, BOOK 2006 PAGE 5703, BOOK 2004 PAGE 16159, BOOK 2006 PAGE 5709 20.00' OVERLAND FLOWAGE EASEMENT, BOOK 2006 PAGE 5703, BOOK 2004 PAGE 16159, BOOK 2004, PAGE 16164 10.00' PUE BOOK 2017 PAGE 4498 25.00' INGRESS/EGRESS EASEMENT BOOK 2015 PAGE 5057 50.00' INGRESS/EGRESS, SANITARY SEWER AND WATER MAIN EASEMENT BOOK 2006, PAGE 5703 20.00' RIGHT OF WAY BOOK 2017 PAGE 4495, BOOK 2017 PAGE 3886 20.00' RIGHT OF WAY BOOK 2017 PAGE 3887 BOOK 2017 PAGE 4499 BOOK 2017 PAGE 4500 TEMPORARY CONSTRUCTION EASEMENT BOOK 2017, PAGE 4498 TEMPORARY CONSTRUCTION EASEMENT BOOK 2017 PAGE 4502 BOOK 2017, PAGE 4499 36.00' B-B Des Moines, Iowa DRAWING NO. CHECKED BY ENGINEER SHEET NO. FIELD BOOK NO. DRAWN BY REVISIONS NOTICE: McClure Engineering Company waives any and all responsibility and liability for problems which arise from failure to follow these Plans, Specifications, and the engineering intent they convey, or for problems which arise from failure to obtain and/or follow the engineers guidance with respect to any errors, omissions, inconsistencies, ambiguities, or conflicts which are alleged. COPYRIGHT: Copyright and property rights in these documents are expressly reserved by McClure Engineering Company. No reproductions, changes, or copies in any manner shall be made without obtaining prior written consent from McClure Engineering Company. 1360 NW 121ST. Street Clive, Iowa 50325 515-964-1229 fax 515-964-2370 making lives better WILLIAMS POINTE COMMERCIAL PLAT 1 PRELIMINARY PLAT WAUKEE, IOWA 20218038-000 MAY 2022 T SMITH T SMITH -- . . . . . 0402PP-02 EXISTING CONDITIONS N: \ P r o j e c t s \ W A K 2 0 2 1 8 0 3 8 \ D w g s \ P l a n s \ P r e l i m i n a r y P l a t \ W i l l i a m s P o i n t e P r e p l a t . d w g 10 / 2 6 / 2 0 2 2 8 : 2 9 A M 25 500 GRAPHIC SCALE 100 NORTH 10.0000' PUE BOOK 2004 PAGE 16159 (TO BE VACATED) 10.00' PUE BOOK 2004 PAGE 16172 (TO BE VACATED) 10.00' PUE BOOK 2006 PAGE 5709 SE A L I C E ' S R D . SE B R I C K D R . SW-301 SW-301 EXISTING-SW-301 94,861 SF 2.18 AC LOT 1 298,241 SF 6.85 AC OUTLOT X S89°46'47"E 285.34' S89°46'47"E 78.82' L=153.73' R=500.00' ∆=17°36'58" CHD=S80°58'18"E CHD L=153.12' S72° 0 9 ' 4 9 " E 238.8 6 ' L=222.77' R=1285.00' ∆=9°55'58" CHD=S12°51'39"W CHD L=222.49' L=170.70' R=1285.00' ∆=7°36'41" CHD=S4°05'19"W CHD L=170.58' S00°16'59"W 94.60' N89°56'22"W 555.79' L=66.50' R=350.00' ∆=10°53'13" CHD=N84°29'46"W CHD L=66.40' L=61.29' R=350.00' ∆=10°02'00" CHD=N84°04'10"W CHD L=61.21' N0 0 ° 1 3 ' 0 8 " E 56 6 . 9 7 ' N71° 3 3 ' 2 2 " W 429.9 9 ' N0 0 ° 0 0 ' 0 0 " E 17 8 . 3 6 ' STOP MANHOLE: 1054.05 15" RCP FL OUT N: 1047.85 15" RCP FL IN S: 1047.85 MANHOLE: 1055.02 15" RCP FL OUT N: 1049.27 15" RCP FL IN E: 1049.34 GUTTER: 1045.24 8" CMP FL IN N: 1043.46 24" RCP FL IN N: 1042.34 8" CMP FL IN E: 1042.34 24" RCP FL OUT S: 1042.3 MANHOLE=1046.22 30" RCP FL OUT SSW=1041.28 GUTTER: 1044.67 15" RCP FL OUT W: 1041.09 8" CMP FL IN E: 1041.97 8" CMP FL IN E: 1041.97 GUTTER: 1043.21 15" RCP FL OUT W: 1039.53 8" CMP FL IN E: 1040.66 MANHOLE: 1052.22 PIPE NOT VISIBLE BOTTOM OF WELL=10421.08 8" PVC FL OUT W: 1040.43 MANHOLE: 1048.57 8" PVC FL IN N: 1037.08 8" PVC FL IN E : 1037.08 8" PVC FL OUT S: 1036.98 FES 24 FL = 1043.41 BUILDING MANHOLE: 1048.92 18" RCP FL OUT SW: 1045.27 18" RCP FL IN E: 1045.29 MANHOLE: 1050.54 18" RCP FL OUT W: 1046.95 18" RCP FL IN SE: 1046.98 MANHOLE: 1048.96 24" RCP FL OUT W: 1043.67 24" RCP FL IN E: 1043.75 GUTTER: 1048.94 BOTTOM WELL: 1045.79 MANHOLE: 1051.29 15" RCP FL OUT SW: 1047.79 GUTTER: 1050.90 15" RCP FL IN NE: 1047.20MANHOLE: 1051.41 18" RCP FL OUT NW: 1047.16 GUTTER: 1048.92 24" RCP FL OUT NW: 1044.33 18" RCP FL IN NE: 1044.51 MANHOLE=1046.99 30" RCP FL IN NNE=1041.26 30" RCP FL OUT S=1041.24 MANHOLE: 1055.58 TOP 4" PIPE W: 1050.62 TOP 4" PIPE E: 1050.58 BOTTOM OF WELL: 1050.12 MANHOLE: 1055.38 BOTTOM OF WELL: 1051.73 TWIN 4" PIPES, CAPPED MANHOLE: 1047.33 BOTTOM OF WELL: 1044.23 TWIN 4" PIPES, CAPPED 12" FES STORM SEWER AND OVERLAND FLOWAGE EASEMENT BOOK 2006 PAGE 5703, BOOK 2006 PAGE 5706, BOOK 2006 PAGE 5707 70.00 ROW 31.00 B-B 25.00 B-B 130.16 ROW TEMPORARY STORM SEWER AND OVERLAND FLOWAGE EASEMENT BOOK 2004, PAGE 16161 50.00' ACCESS EASEMENT BOOK 2017 PAGE 3887 30.00' OVERLAND FLOWAGE EASEMENT BOOK 2004, PAGE 16172 BOOK 2004, PAGE 16177 10.00' PUE BOOK 2004, PAGE 16172 10.00' QWEST EASEMENT BOOK 2010 PAGE 17568 10.00' PUE, BOOK 2006 PAGE 5703, BOOK 2004 PAGE 16159, BOOK 2006 PAGE 5709 10.00' PUE BOOK 2017 PAGE 4498 25.00' INGRESS/EGRESS EASEMENT BOOK 2015 PAGE 5057 50.00' INGRESS/EGRESS, SANITARY SEWER AND WATER MAIN EASEMENT BOOK 2006, PAGE 5703 20.00' RIGHT OF WAY BOOK 2017 PAGE 4495, BOOK 2017 PAGE 3886 TEMPORARY CONSTRUCTION EASEMENT BOOK 2017, PAGE 4498 TEMPORARY CONSTRUCTION EASEMENT BOOK 2017 PAGE 4502 BOOK 2017, PAGE 4499 97.79 B-B 36.00' B-B STORM SEWER AND OVERLAND FLOWAGE EASEMENT BOOK 2006 PAGE 5703, BOOK 2006 PAGE 5706, BOOK 2006 PAGE 5707 TEMPORARY STORM SEWER AND OVERLAND FLOWAGE EASEMENT BOOK 2004, PAGE 16161 50.00' ACCESS EASEMENT BOOK 2017 PAGE 3887 30.00' OVERLAND FLOWAGE EASEMENT BOOK 2004, PAGE 16172 BOOK 2004, PAGE 16177 10.00' PUE BOOK 2004, PAGE 16172 10.00' QWEST EASEMENT BOOK 2010 PAGE 17568 10.00' PUE, BOOK 2006 PAGE 5703, BOOK 2004 PAGE 16159, BOOK 2006 PAGE 5709 10.00' PUE BOOK 2017 PAGE 4498 25.00' INGRESS/EGRESS EASEMENT BOOK 2015 PAGE 5057 50.00' INGRESS/EGRESS, SANITARY SEWER AND WATER MAIN EASEMENT BOOK 2006, PAGE 5703 20.00' RIGHT OF WAY BOOK 2017 PAGE 4495, BOOK 2017 PAGE 3886 TEMPORARY CONSTRUCTION EASEMENT BOOK 2017, PAGE 4498 TEMPORARY CONSTRUCTION EASEMENT BOOK 2017 PAGE 4502 BOOK 2017, PAGE 4499 36.00' B-B STORM SEWER AND OVERLAND FLOWAGE EASEMENT BOOK 2006 PAGE 5703, BOOK 2006 PAGE 5706, BOOK 2006 PAGE 5707 TEMPORARY STORM SEWER AND OVERLAND FLOWAGE EASEMENT BOOK 2004, PAGE 16161 50.00' ACCESS EASEMENT BOOK 2017 PAGE 3887 30.00' OVERLAND FLOWAGE EASEMENT BOOK 2004, PAGE 16172 BOOK 2004, PAGE 16177 10.00' PUE BOOK 2004, PAGE 16172 10.00' QWEST EASEMENT BOOK 2010 PAGE 17568 10.00' PUE, BOOK 2006 PAGE 5703, BOOK 2004 PAGE 16159, BOOK 2006 PAGE 5709 20.00' OVERLAND FLOWAGE EASEMENT, BOOK 2006 PAGE 5703, BOOK 2004 PAGE 16159, BOOK 2004, PAGE 16164 10.00' PUE BOOK 2017 PAGE 4498 25.00' INGRESS/EGRESS EASEMENT BOOK 2015 PAGE 5057 50.00' INGRESS/EGRESS, SANITARY SEWER AND WATER MAIN EASEMENT BOOK 2006, PAGE 5703 20.00' RIGHT OF WAY BOOK 2017 PAGE 4495, BOOK 2017 PAGE 3886 20.00' RIGHT OF WAY BOOK 2017 PAGE 3887 BOOK 2017 PAGE 4499 BOOK 2017 PAGE 4500 TEMPORARY CONSTRUCTION EASEMENT BOOK 2017, PAGE 4498 TEMPORARY CONSTRUCTION EASEMENT BOOK 2017 PAGE 4502 BOOK 2017, PAGE 4499 36.00' B-B Des Moines, Iowa 1045104210431044 1046 1047104 8 FES-1, FES PIPE STA = 100+48.63 INV. OUT (W) = 1040.65 P-1 P-1 46.13 LF 15" RCP @ 2.06% -3 1 . 9 1 % -3 0 . 6 1 % -2.04% SSMH-104, SW-301 RIM = 1049.15 INV. OUT (S) = 1040.63 P-104 SSMH-103, SW-301 RIM = 1048.48 INV. IN (N) = 1039.73 P-104 INV. OUT (S) = 1039.48 P-103 DRAWING NO. CHECKED BY ENGINEER SHEET NO. FIELD BOOK NO. DRAWN BY REVISIONS NOTICE: McClure Engineering Company waives any and all responsibility and liability for problems which arise from failure to follow these Plans, Specifications, and the engineering intent they convey, or for problems which arise from failure to obtain and/or follow the engineers guidance with respect to any errors, omissions, inconsistencies, ambiguities, or conflicts which are alleged. COPYRIGHT: Copyright and property rights in these documents are expressly reserved by McClure Engineering Company. No reproductions, changes, or copies in any manner shall be made without obtaining prior written consent from McClure Engineering Company. 1360 NW 121ST. Street Clive, Iowa 50325 515-964-1229 fax 515-964-2370 making lives better WILLIAMS POINTE COMMERCIAL PLAT 1 PRELIMINARY PLAT WAUKEE, IOWA 20218038-000 MAY 2022 T SMITH T SMITH -- . . . . . 0403PP-03 GENERAL LAYOUT N: \ P r o j e c t s \ W A K 2 0 2 1 8 0 3 8 \ D w g s \ P l a n s \ P r e l i m i n a r y P l a t \ W i l l i a m s P o i n t e P r e p l a t . d w g 10 / 2 6 / 2 0 2 2 8 : 2 9 A M 25 500 GRAPHIC SCALE 100 NORTH 30.00' PRIVATE SANITARY EASEMENT 30' LA N D S C A P E B U F F E R SETB A C K 30 ' F R O N T SE T B A C K 30 ' R E A R S E T B A C K 10.00' PUE BOOK 2006 PAGE 5709 10.00' PUE 10.00' P.U.E 10.00' P.U.E PRIVATE SANITARY SEWER 10.00' GAS EASEMENT 40.00' STORM SEWER AND SURFACE WATER FLOWAGE EASEMENT CONTRACTOR TO FIELD VERIFY LOCATION AND ELEVATION OF SANITARY SEWER STUB 26.00' ACCESS EASEMENT 26' PRIVATE DRIVE TO BE EXTENDED WITH FUTURE DEVELOPMENT NOTE: PROPOSED PIPE AND STORMWATER FLOWAGE EASEMENT MAY BE ABANDONED TO ACCOMMODATE FUTURE DEVELOPMENT IN THIS SUBDIVISION. COST OF ABANDONMENT SHALL BE INCURRED BY FUTURE TENANT AND RELOCATED STORM SEWER SHALL BE PROVIDED TO CONVEY LOT 1'S ALLOWABLE DISCHARGE TIE TO EXISTING SW-505 PROPOSED FL = 1039.70 SE A L I C E ' S R D . SE B R I C K D R . SW-301 SW-301 EXISTING-SW-301 94,861 SF 2.18 AC LOT 1 298,241 SF 6.85 AC OUTLOT X S89°46'47"E 285.34' S89°46'47"E 78.82' L=153.73' R=500.00' ∆=17°36'58" CHD=S80°58'18"E CHD L=153.12' S72° 0 9 ' 4 9 " E 238.8 6 ' L=222.77' R=1285.00' ∆=9°55'58" CHD=S12°51'39"W CHD L=222.49' L=170.70' R=1285.00' ∆=7°36'41" CHD=S4°05'19"W CHD L=170.58' S00°16'59"W 94.60' N89°56'22"W 555.79' L=66.50' R=350.00' ∆=10°53'13" CHD=N84°29'46"W CHD L=66.40' L=61.29' R=350.00' ∆=10°02'00" CHD=N84°04'10"W CHD L=61.21' N0 0 ° 1 3 ' 0 8 " E 56 6 . 9 7 ' N71° 3 3 ' 2 2 " W 429.9 9 ' N0 0 ° 0 0 ' 0 0 " E 17 8 . 3 6 ' STOP MANHOLE: 1054.05 15" RCP FL OUT N: 1047.85 15" RCP FL IN S: 1047.85 MANHOLE: 1055.02 15" RCP FL OUT N: 1049.27 15" RCP FL IN E: 1049.34 GUTTER: 1045.24 8" CMP FL IN N: 1043.46 24" RCP FL IN N: 1042.34 8" CMP FL IN E: 1042.34 24" RCP FL OUT S: 1042.3 MANHOLE=1046.22 30" RCP FL OUT SSW=1041.28 GUTTER: 1044.67 15" RCP FL OUT W: 1041.09 8" CMP FL IN E: 1041.97 8" CMP FL IN E: 1041.97 GUTTER: 1043.21 15" RCP FL OUT W: 1039.53 8" CMP FL IN E: 1040.66 MANHOLE: 1052.22 PIPE NOT VISIBLE BOTTOM OF WELL=10421.08 8" PVC FL OUT W: 1040.43 MANHOLE: 1048.57 8" PVC FL IN N: 1037.08 8" PVC FL IN E : 1037.08 8" PVC FL OUT S: 1036.98 FES 24 FL = 1043.41 BUILDING MANHOLE: 1048.92 18" RCP FL OUT SW: 1045.27 18" RCP FL IN E: 1045.29 MANHOLE: 1050.54 18" RCP FL OUT W: 1046.95 18" RCP FL IN SE: 1046.98 MANHOLE: 1048.96 24" RCP FL OUT W: 1043.67 24" RCP FL IN E: 1043.75 GUTTER: 1048.94 BOTTOM WELL: 1045.79 MANHOLE: 1051.29 15" RCP FL OUT SW: 1047.79 GUTTER: 1050.90 15" RCP FL IN NE: 1047.20MANHOLE: 1051.41 18" RCP FL OUT NW: 1047.16 GUTTER: 1048.92 24" RCP FL OUT NW: 1044.33 18" RCP FL IN NE: 1044.51 MANHOLE=1046.99 30" RCP FL IN NNE=1041.26 30" RCP FL OUT S=1041.24 MANHOLE: 1055.58 TOP 4" PIPE W: 1050.62 TOP 4" PIPE E: 1050.58 BOTTOM OF WELL: 1050.12 MANHOLE: 1055.38 BOTTOM OF WELL: 1051.73 TWIN 4" PIPES, CAPPED MANHOLE: 1047.33 BOTTOM OF WELL: 1044.23 TWIN 4" PIPES, CAPPED 12" FES 70.00 ROW 31.00 B-B 25.00 B-B 130.16 ROW 97.79 B-B SSMH-104, SW-301 RIM = 1049.15 INV. OUT (S) = 1040.63 P-104 SSMH-103, SW-301 RIM = 1048.48 INV. IN (N) = 1039.73 P-104 INV. OUT (S) = 1039.48 P-103 DRAWING NO. CHECKED BY ENGINEER SHEET NO. FIELD BOOK NO. DRAWN BY REVISIONS NOTICE: McClure Engineering Company waives any and all responsibility and liability for problems which arise from failure to follow these Plans, Specifications, and the engineering intent they convey, or for problems which arise from failure to obtain and/or follow the engineers guidance with respect to any errors, omissions, inconsistencies, ambiguities, or conflicts which are alleged. COPYRIGHT: Copyright and property rights in these documents are expressly reserved by McClure Engineering Company. No reproductions, changes, or copies in any manner shall be made without obtaining prior written consent from McClure Engineering Company. 1360 NW 121ST. Street Clive, Iowa 50325 515-964-1229 fax 515-964-2370 making lives better WILLIAMS POINTE COMMERCIAL PLAT 1 PRELIMINARY PLAT WAUKEE, IOWA 20218038-000 MAY 2022 T SMITH T SMITH -- . . . . . 0404PP-04 CONTROL PLAN EROSION & SEDIMENT N: \ P r o j e c t s \ W A K 2 0 2 1 8 0 3 8 \ D w g s \ P l a n s \ P r e l i m i n a r y P l a t \ W i l l i a m s P o i n t e P r e p l a t . d w g 10 / 2 6 / 2 0 2 2 8 : 3 0 A M 25 500 GRAPHIC SCALE 100 NORTH 30' LA N D S C A P E B U F F E R EASE M E N T 30 ' F R O N T SE T B A C K 30 ' L A N D S C A P E B U F F E R EA S E M E N T DUMPSTER LINED OR ROLL OFF WASH OUT STAGING AREA / EQUIPMENT STORAGE PORTABLE RESTROOM W PR ROCK CONSTRUCTION ENTRANCE 24' x 60 ' SILT FENCE (TYP) ITEM QUANTITY UNIT SILT FENCE 1550 LINEAR FEET BELOW GRADE INTAKE PROTECTION (POST PAVING)5 EACH ROCK CONSTRUCTION ENTRANCE 1 EACH STAGING AREA 1 EACH DUMPSTER 1 EACH PORTABLE RESTROOM 1 EACH WASH OUT 1 EACH DISTURBED AREA 1.95 ACRE TOP SOIL STOCKPILE LOCATION APPROXIMATE LIMITS OF DISTRURBANCE DISCHARGE POINT #2 - TO SUGAR CREEK TRIBUTARIES DISCHARGE POINT #1 - TO SUGAR CREEK TRIBUTARIES N0 0 ° 1 3 ' 0 8 " E 5 6 6 . 9 7 ' ( M ) N0 0 ° 2 1 ' 1 9 " E 5 6 6 . 9 9 ' ( R ) S89°46'47"E 364.16'(M) S89°41'07"E 364.16'(R) L=153.73'(M&R) R=500.00'( M&R) ∆=17°36'58"(M&R) CHD=S80°58'18"E(M) CHD=S80°52'38"E(R) CHD L=153.12'(M&R) S72° 0 9 ' 4 9 " E 2 3 8 . 8 6 ' ( M ) S72° 0 4 ' 0 9 " E 2 3 8 . 8 3 ' ( R ) L=393.47'(M) L=393.47'(R) R=1285.00'(M&R) ∆=17°32'39"(M) ∆=17°32'39"(R) CHD=S9°03'18"W(M) CHD L=391.94'(M) S0 0 ° 1 6 ' 5 9 " W 9 4 . 6 0 ' ( M ) S0 0 ° 2 2 ' 4 4 " W 9 4 . 4 5 ' ( R ) N89°56'22"W 555.79'(M) N89°50'37"W 555.79'(R) L=66.50'(M) 66.51'(R) R=350.00'(M&R) ∆=10°53'13"(M&R) CHD=N84°29'46"W(M) CHD=N84°24'01"W(R) CHD L=66.40'(M) 66.41'(R) L=61.29'(M) 61.28'(R) R=350.00'(M&R) ∆=10°02'00"(M) ∆=10°01'55"(R) CHD=N84°04'10"W(M) CHD=N83°58'21"W(R) CHD L=61.21'(M) 61.20'(R) LOT 1 2.18 AC OUTLOT X 6.85 AC N0 0 ° 0 0 ' 0 0 " E 1 7 8 . 3 6 ' S89°46'47"E 78.82' L=222.77' R=1285.00' ∆=9°55'58" CHD=S12°51'39"W CHD L=222.49' N71° 3 3 ' 2 2 " W 4 2 9 . 9 9 ' L=170.70' R=1285.00' ∆=7°36'41" CHD=S04°05'19"W CHD L=170.58' S89°46'47"E 285.34' 133.98' N00°00'00"E 25.00' N77°39'33"E 65.38' N0 0 ° 0 0 ' 3 6 " E 3 8 4 . 2 6 ' N90°00'00"E 285.81' N89°46'47"W 243.03' N44°53'23"W 41.60' N0 0 ° 0 0 ' 0 0 " E 1 4 4 . 4 7 ' S00°00'00"E 6.08' S90°00'00"W 26.00' S71°33'22"E 13.70' N89°56'22"W 545.00' N79°18' 2 6 " W 8 9 . 3 5 ' S00°13'08"W 10.17' S79°18'2 6 " E 8 8 . 4 3 ' S89°56'22"E 545.89' N00°16'59"E 10.00' N89°56'22"W 10.00' 25 . 0 0 ' N89°44'03"W 10.04' L=62.09' R=1285.00' ∆=2°46'07" CHD=S6°30'36"W CHD L=62.09' S71°33'22"E 10.17' L=65.29' R=1295.00' ∆=2°53'19" CHD=N6°31'57"E CHD L=65.28' 421.81' N00°13'08"E 15.00' S0 0 ° 0 0 ' 0 0 " E 1 7 8 . 3 6 ' S00°00'00"E 40.00' N90°00'00"W 285.96' N00°13'08"E 40.00' N89°44'03"W 676.78'N00°13'08"E 10.00' S89°44'03"E 677.60' L=10.03' R=1295.00' ∆=0°26'38" CHD=S4°51'58"W CHD L=10.03' S89°44'03"E 668.53' L=10.04' R=1285.00' ∆=0°26'52" CHD=S5°20'58"W CHD L=10.04' N89°44'03"W 667.63'N00°13'08"E 10.00' PATRICK SHELQUIST MY LICENSE RENEWAL DATE IS DECEMBER 31, 2023 I HEREBY CERTIFY THAT THIS LAND SURVEYING DOCUMENT WAS PREPARED AND THE RELATED WORK WAS PERFORMED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED LAND SURVEYOR UNDER THE LAWS OF THE STATE OF IOWA. DATE SURVEYED: PAGES OR SHEETS COVERED BY THIS SEAL: DATE DSDS WAUKEE, LLC (F/K/A CORALVILLE AAP, LLC) 9251 WILLOW LANE FREMONT, WI 54940 ATTN: DAVE HERBECK PHONE # 920-428-9028 DAVE@HERBECKDEVELOPMENT.COM C-1 COMMUNITY AND HIGHWAY SERVICE COMMERCIAL DISTRICT WARRANTY DEED FILED IN BOOK 2018 PAGE 15732: PARCEL "AA" OF THE SURVEY OF PART OF LOT 2 WILLIAMS POINTE PLAT 7, AN OFFICIAL PLAT LOCATED IN WAUKEE, DALLAS COUNTY, IOWA AS RECORDED IN BOOK 2014, PAGE 11668, EXCEPT LAND DEEDED TO THE CITY OF WAUKEE AS RECORDED IN BOOK 2017, PAGE 4500. SUBJECT TO EASEMENTS, RESTRICTIONS AND COVENANTS OF RECORD. AND LOT 2 IN WILLIAMS POINTE PLAT 9, AN OFFICIAL PLAT, WAUKEE, DALLAS COUNTY, IOWA, EXCEPT WILLIAMS POINTE PLAT 15 AND EXCEPT LAND DEEDED TO THE CITY OF WAUKEE AS RECORDED IN BOOK 2017, PAGE 4495. SUBJECT TO EASEMENTS, RESTRICTIONS AND COVENANTS OF RECORD. TOTAL ACRES: 9.03 AC MCCLURE 1360 NW 121ST STREET CLIVE, IA 50325 (515) 964-1229 TSMITH@MCCLUREVISION.COM ATTN: TRENT SMITH DR A W I N G P A T H : PL O T D A T E : PL O T T E D B Y : DRAWING NO. CREW CHIEF ENGINEER SHEET NO. SURVEYOR DRAWN BY REVISIONS /01 NORTH making lives better. (IN FEET) WILLIAMS POINTE COMMERCIAL PLAT 1 WAUKEE, IOWA DALLAS COUNTY 20218038-010 DATE: 5-13-2022 7/1/2022 8/22/2022 . . . TS ML PS KB FP-01 01 4020100 335 SE Oralabor Road Ankeny, Iowa 50021 515-512-1361 1 inch = 40 ft. PART: PARCEL 'AA' OF LOT 2, WILLIAMS POINTE PLAT 7 CITY: WAUKEE PROPRIETOR: CORALVILLE, AAP, LLC REQUESTED BY: CORALVILLE, AAP, LLC SURVEYOR: PATRICK SHELQUIST COMPANY: McCLURE ENGINEERING RETURN TO: PATRICK SHELQUIST 335 SE ORALABOR ROAD ANKENY, IOWA 50021 / 515-512-1361 COUNTY: DALLAS SURVEY BOUNDARY PROPOSED LOT EXIST PROPERTY LINE SECTION LINE SETBACK LINE PROPOSED EASEMENT EXIST EASEMENT FND BK, PG (M), (R) R.O.W. P.U.E. P.O.B. P.O.C. FOUND BOOK AND PAGE MEASURED, RECORDED RIGHT-OF-WAY PUBLIC UTILITY EASEMENT POINT OF BEGINNING POINT OF COMMENCEMENT MONUMENTS FOUND: SECTION CORNER (TYPE AS NOTED) 1/2" REBAR W/YPC #16747 (UNLESS NOTED OTHERWISE) SECTION CORNER 1/2" REBAR W/YPC #24477 1/2" REBAR W/YPC #24477 MONUMENTS SET: CUT X PART: PT OF LOT 2, WILLIAMS POINTE PLAT 9 1048 1047 1046 45 1045 1046 DR I V E SE B R I C K D R I V E DRAWING INFORMATION PROJECT NO: ISSUED FOR: CHECK BY: DRAWN BY: SHEET NUMBER ENGINEERS · SURVEYORS LABORATORIES · DRILLING 3213 S WEST BYPASS SPRINGFIELD, MO 65807 PHONE (417) 866-2741 SHEET TITLE DATEDESCRIPTIONNO. ISSUED FOR ISSUED BY: LICENSE NO: ISSUED DATE: GERBER COLLISION & GLASS WILLIAMS POINTE WAUKEE, IA CMH JMD JARED M. DAVIS PE No. P25497 A LICENSED MISSOURI ENGINEERING CORPORATION COA 00062 22SP10014 PERMIT 06/07/2022 EXP: 12/31/2022 C0 CIVIL TITLE SHEET SHEET INDEX DESCRIPTION CIVIL TITLE SHEET SITE LAYOUT & DIMENSION PLAN SUFFIX C0 C1 SITE DETAILS SITE GRADING AND STORM SEWER PLAN C1.1 GRADING PLAN AND STRUCTURE DETAILS C2 C2.2 C3 C3.1 EROSION & SEDIMENT CONTROL PLAN C4SITE UTILITY PLAN EROSION & SEDIMENT CONTROL DETAILS C5LANDSCAPE PLAN MECHANICAL : PETER BALMES, DIRECTOR OF MARKET & RE DEVELOPMENT 630-532-3397 ARCHITECT : CIVIL ENGINEER : STRUCTURAL ENGINEER : ELECTRICAL ENGINEER : PLUMBING : CLIENT/OWNER : GERBER COLLISION & GLASS c/o THE BOYD GROUP 400 W GRAND AVENUE ELMHURST, IL 60126 PROJECT TEAM CURRENT USE ZONING CLASS PROPOSED USE PROJECT ADDRESS DESCRIPTION PROJECT DATA GERBER COLLISION & GLASS 950 SE BRICK DRIVE WAUKEE, IA NEW, FREESTANDING, SINGLE-STORY, SINGLE-OCCUPANT, STEEL FRAMED REPAIR GARAGE FUNCTIONAL AREAS OF THIS FACILITY INCLUDES BUSINESS USE AREAS AND A SERVICE GARAGE WITH ACCESSORY USE STORAGE AND UTILITY SPACES. BUILDING IS APPROXIMATELY 14,221 SF. VACANT LOT C-1 COMMUNITY AND HIGHWAY SERVICE COMMERCIAL DISTRICT AUTOMOBILE REPAIR STATION NORM HERMAN 45 SPYGLASS DRIVE LITTLETON, COLORADO 80123 MOBILE: 303 881 8925 normherman@arcodev.com C6STORMWATER MAINTENANCE PLAN OVERALL SITE PLAN SCALE: 1" = 30' 1 C0 C-1 COMMUNITY AND HIGHWAY SERVICE COMMERCIAL DISTRICT FRONT BUILDING SETBACK - 30 FEET REAR BUILDING SETBACK - 30 FEET SIDE BUILDING SETBACK - NO MINIMUM, EXCEPT WHEN ADJACENT TO ANY R DISTRICT, THE MINIMUM SIDE YARD SETBACK SHALL BE 30 FEET. MAXIMUM HEIGHT - NO MINIMUM EXCEPT WHEN ADJACENT TO AN R-1, R-2 OR R-4 DISTRICT, THE MAXIMUM SHALL BE 2 STORIES OR 40 FEET GERBER COLLISION & GLASS CIVIL SITE PLANS WAUKEE, IA1. SITE CONDITIONS BASED UPON SURVEY SUBMITTED BY OWNER. THE CONTRACTOR SHALL FIELD VERIFY ALL HORIZONTAL AND VERTICAL LINES AND GRADES OF EXISTING UTILITIES PRIOR TO THE CONSTRUCTION OF IMPROVEMENTS. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY UPON DISCOVERING A DISCREPANCY BETWEEN THE CONTRACT DRAWINGS AND ACTUAL FIELD CONDITIONS. CONTACT ONE CALL: 1-800-292-8989. 2. THE CONTRACTOR MUST COORDINATE CONSTRUCTION WITH THE NECESSARY AUTHORITIES. 3. APPLICABLE PERMITS MUST BE OBTAINED PRIOR TO EXCAVATION WITHIN ANY RIGHT-OF-WAY, AND PRIOR TO ANY CONSTRUCTION. 4. PROVIDE POSITIVE DRAINAGE AWAY FROM ALL BUILDINGS WITHOUT PONDING ON PARKING LOTS OR SIDEWALKS. ALL IMPROVED RUNOFF TO DRAIN TO DRAINWAYS. 5. ALL CONTOURS AND SPOT ELEVATIONS SHOWN ARE FINISH GRADE. 6. THE REMOVAL OF ANY TREES SHALL BE APPROVED BY THE PROJECT MANAGER PRIOR TO REMOVAL. 7. COORDINATE WORK WITH OTHER SITE RELATED DEVELOPMENT DRAWINGS. 8. TESTING OF CONTROLLED STRUCTURAL FILL, OBSERVATION OF EXCAVATIONS AND COMPACTION OF SUBGRADE SHALL BE DONE BY A QUALIFIED GEOTECHNICAL ENGINEER. FOLLOW GEOTECHNICAL ENGINEER RECOMMENDATIONS FOR SITE EXCAVATION REQUIREMENTS. 10. REFER TO STRUCTURAL DRAWINGS FOR BUILDING EXCAVATION REQUIREMENTS. 11. GRADING AT HANDICAP ACCESSIBLE PARKING SPACES SHALL NOT EXCEED 2% IN ANY DIRECTION. GRADING AT HANDICAP ACCESSIBLE ROUTE SHALL NOT EXCEED 5% IN DIRECTION OF TRAVEL WITH 2% MAXIMUM CROSS SLOPE. GRADING AT BUILDING EGRESS DOORS SHALL NOT EXCEED 2% FOR A DISTANCE OF 5'-0" PERPENDICULAR FROM FACE OF DOOR. 12. REFER TO PROJECT MANUAL FOR ADDITIONAL REQUIREMENTS. GENERAL NOTES: CONTRACTOR SHALL FIELD VERIFY PROPOSED GRADES MATCH EXISTING PAVEMENT AT DRIVEWAY ENTRANCES, SIDEWALK CONNECTIONS, AND ALL CONNECTION POINTS PRIOR TO BEGINNING CONSTRUCTION. CONTRACTOR SHALL NOTIFY ENGINEER IF DISCREPANCY OCCURS. CONTRACTOR SHALL REPAIR AND/OR REPLACE ANY DAMAGED AREAS OF PAVEMENT DUE TO CONSTRUCTION ACTIVITIES. CONTRACTOR SHALL PICK UP DEBRIS SPILLED ONTO THE STREET AT THE END OF EACH WORKDAY AND PRIOR TO A RAIN EVENT. ALL PROPOSED SIGNAGE IS REVIEWED UNDER A SEPARATE REVIEW. 1. IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. 2. THE DUTY OF THE ENGINEER OR OWNER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES IN, ON, OR NEAR THE CONSTRUCTION SITE. SAFETY NOTES: 06/27/2022 2 CITY COMMENTS 07/25/2022 SPECIAL NOTE: ALL WORK DONE ON THE PROJECT SHALL BE IN CONFORMANCE WITH 2020 WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND 2022 SUDAS. LEGAL DESCRIPTION ALL OF LOT 1 OF THE WILLIAMS COMMERCIAL PLAT 1 SUBDIVISION. CONTAINING 2.18 ACRES MORE OR LESS. STORM SEWER STRUCTURE DETAILS C2.1 3 CITY COMMENTS 08/09/2022 C6.1ADS MAINTENANCE PLAN C7ADS BED 1 STORMTECH DETAILS 1 4 CITY COMMENTS 08/23/2022 C7.1ADS BED 1 STORMTECH DETAILS 2 C8ADS BED 2 STORMTECH DETAILS 1 C8.1ADS BED 2 STORMTECH DETAILS 2 8 CITY COMMENTS 10/24/2022 8 8 Digitally signed by Jared Davis, PE DN: C=US, E=jmdavis@andersonengineeringinc.com, O="Anderson Engineering, Inc", OU=VP, CN="Jared Davis, PE" Date: 2022.10.27 14:20:53-05'00' DR I V E SE B R I C K D R I V E SITE LAYOUT AND DIMENSION PLAN SCALE: 1" = 30' 1 C1 DRAWING INFORMATION PROJECT NO: ISSUED FOR: CHECK BY: DRAWN BY: SHEET NUMBER ENGINEERS · SURVEYORS LABORATORIES · DRILLING 3213 S WEST BYPASS SPRINGFIELD, MO 65807 PHONE (417) 866-2741 SHEET TITLE DATEDESCRIPTIONNO. ISSUED FOR ISSUED BY: LICENSE NO: ISSUED DATE: GERBER COLLISION & GLASS WILLIAMS POINTE WAUKEE, IA CMH JMD JARED M. DAVIS PE No. P25497 A LICENSED MISSOURI ENGINEERING CORPORATION COA 00062 22SP10014 PERMIT 06/07/2022 EXP: 12/31/2022 C1 SITE LAYOUT AND DIMENSION PLAN 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DEMOLITION AND REMOVAL OF ALL ITEMS THAT IMPEDE THE PROPER PLACEMENT OF ANY ITEMS PROPOSED BY THIS PLAN SET. 2. THE REMOVAL WORK SHALL INCLUDE BUT NOT BE LIMITED TO: OBTAINING ALL DEMOLITION PERMITS REQUIRED, REMOVAL OF THE EXISTING TREES, SEALING OF EXISTING WATER WELLS, REMOVAL OF ANY SEPTIC SYSTEM OR DRY WELLS AND OTHER ITEMS TO COMPLETE THE REMOVALS. 3. THE CONTRACTOR SHALL REMOVE ALL MATERIALS DEEMED UNSUITABLE BY THE ENGINEER WITHIN EIGHT INCHES OF THE PROPOSED BUILDING FOOTPRINT TO THE DEPTH THAT SUCH UNSUITABLE MATERIALS EXIST. VOIDS SHALL BE FILLED IN ACCORDANCE WITH RECOMMENDATIONS FROM A CERTIFIED GEOTECHNICAL ENGINEER. 4. TREE REMOVAL SHALL INCLUDE THE COMPLETE REMOVAL OF TREES AS NOTED ON THE PLAN, INCLUDING ALL STUMPS AND ROOTS. IF ADDITIONAL TREES ARE DEEMED NECESSARY TO BE REMOVED BY THE CONTRACTOR, CONTRACTOR MUST OBTAIN WRITTEN PERMISSION FROM THE ENGINEER PRIOR TO REMOVAL OF SAID TREES. THE CONTRACTOR SHALL PROVIDE WRITTEN NOTIFICATION TO THE ENGINEER A MINIMUM OF 10 DAYS PRIOR TO REMOVAL. 5. THE CONTRACTOR SHALL COORDINATE DISCONNECTION, REMOVAL, AND RELOCATION OF ANY EXISTING UTILITIES WITH THE APPROPRIATE UTILITY COMPANIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FEES THAT ARE LEVIED BY UTILITY COMPANIES IN CONJUNCTION WITH DEMOLITION AND REMOVAL OF EXISTING UTILITIES. 6. DISPOSAL OF ALL MATERIALS SHALL COMPLY WITH ALL LOCAL, STATE, AND FEDERAL REGULATIONS. ALL WASTE MATERIAL SHALL BE DISPOSED OF OFF-SITE. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL OF ALL MATERIALS FROM THE SITE ALONG WITH ALL ASSOCIATED PERMITS AND REGULATORY REQUIREMENTS. 7. IF NECESSARY, THE CONTRACTOR SHALL BE FAMILIAR WITH THE APPROPRIATE SPECIFICATIONS FOR WELL ABANDONMENT, MATERIALS, PROCEDURES AND ACCESS TO EQUIPMENT REQUIRED TO PROPERLY SEAL WELLS. THE CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN, COMPLETE AND FILE THE APPROPRIATE FORMS THROUGH THE LOCAL JURISDICTION AND/OR THE IOWA DEPARTMENT OF NATURAL RESOURCES. 8. THE CONTRACTOR SHALL MAINTAIN ALL EXISTING UTILITY SERVICES TO ADJACENT LOTS. INTERRUPTION OF SERVICES TO ADJACENT LOTS SHALL NOT OCCUR WITHOUT PROPER APPROVAL. 48 HOURS NOTICE SHALL BE GIVEN TO THE PROPERTY OWNERS PRIOR TO THE CONNECTION OF THE NEW SERVICES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COSTS ASSOCIATED WITH THE CONNECTION OF TEMPORARY UTILITY SERVICES, IF REQUIRED, TO FACILITATE CONSTRUCTION STAGING. 9. THE CONTRACTOR SHALL MAINTAIN ALL EXISTING PARKING, SIDEWALKS, DRIVES, ETC. TO BE CLEAR AND FREE OF ANY CONSTRUCTION ACTIVITY AND/OR EXCAVATED AND HAULED MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND VEHICULAR TRAFFIC TO AND FROM ADJACENT SITES. 10.THE CONTRACTOR SHALL PERFORM A FULL-DEPTH SAW-CUT ALONG THE PERIMETER OF PAVEMENT AND SIDEWALK REMOVAL THAT ABUTS EXISTING PAVEMENT AND SIDEWALK THAT IS TO REMAIN. 11.ANY DAMAGE SUSTAINED BY ITEMS THAT ARE TO REMAIN IN PLACE SHALL BE REPAIRED OR REPLACED TO THE OWNER'S SATISFACTION AT NO COST TO THE OWNER. DEMOLITION NOTES: FIELD VERIFY SANITARY SEWER AND STORM SEWER CONNECTION INVERT PRIOR TO ESTABLISHING FINAL FINISH FLOOR ELEVATION. REFER TO SITE UTILITIES PLAN. CONTRACTOR TO PERFORM DETAILED SITE INSPECTION TO LOCATE ALL EXISTING UTILITES AND VERIFY ANY POSSIBLE CONFLICTS WITH PROPOSED IMPROVEMENTS PRIOR TO BEGINNING ANY CONSTRUCTION. CONTACT ENGINEER WITH ANY CONFLICTS. CONTRACTOR SHALL FIELD VERIFY PROPOSED GRADES MATCH EXISTING PAVEMENT AT DRIVEWAY ENTRANCES, SIDEWALK CONNECTIONS, AND ALL CONNECTION POINTS PRIOR TO BEGINNING CONSTRUCTION. CONTRACTOR SHALL NOTIFY ENGINEER IF DISCREPANCY OCCURS. PARKING CALCULATION AUTOMOBILE REPAIR STATIONS: 3 SPACES PER SERVICE BAY; 1 SPACE PER SERVICE VEHICLE; 2.5 SPACES PER 1,000 SQUARE FEET OF NON-SERVICE AREA REQUIRED HANDICAP PARKING 0 VEHICLES PROVIDED HANDICAP PARKING TOTAL SERVICE BAYS 13 BAYS STANDARD DUTY CONCRETE PAVEMENT LEGEND TOTAL SERVICE VEHICLES REQUIRED PARKING 39 SPACES 0 SPACES TOTAL REQUIRED PARKING 44 SPACES 2 SPACES 2 SPACES KEY NOTES: 1 2 3 4 5 6 7 8 9 10 11 NEW CURB AND GUTTER PER DETAIL 1/C1.1. STRIPING TO BE 4" HI-VIS WHITE PER CITY OF WAUKEE STANDARDS AND SPECS. INSTALL ADA ACCESSIBLE SYMBOL PER DETAIL 2/C1.1. MATCH NEW PAVEMENT FLUSH WITH EXISTING PAVEMENT. INSTALL ADA POLE MOUNTED SIGNAGE PER DETAIL 3/C1.1. NEW SIDEWALK REFER TO DETAIL 4/C1.1. TURNDOWN SIDEWALK ADJACENT TO PAVEMENT REFER TO DETAIL 5/C1.1. NEW STANDARD DUTY CONCRETE PAVEMENT PER DETAIL 6/C1.1. TRASH ENCLOSURE WITH HEAVY DUTY CONCRETE PAVEMENT. REFER TO DETAIL 8/C1.1 AND ARCHITECTURAL PLANS. HANDICAP ACCESS UNLOADING ZONE: SLOPE 2% MAX. EACH WAY (ADA COMPLIANT) AND STRIPE AS SHOWN. 4" STRIPES @ 24" O.C. AT 45 DEGREES. PAINT COLOR TO BE PER THE AUTHORITY HAVING JURISDICTION. LIMITS OF SAWCUT. BICYCLE PARKING. REFER TO DETAIL 7/C1.1. 3' CURB CUT. FIRE LANE STRIPING SHOWN FOR REFERENCE. STRIPE AS SHOWN ONLY IF REQUIRED BY THE CITY OF WAUKEE. REFER TO STRIPING NOTES IF REQUIRED. MONUMENT SIGN. REFER TO ARCHITECTURAL DRAWINGS. INSTALL GATE WITH KNOX PADLOCK. GATE TO BE A MINIMUM OF 20' WIDE FOR FIRE ACCESS. INSTALL FENCETRAC PANEL PRIVACY FENCE SYSTEM MAX HEIGHT: 6' ABOVE GRADE. NOT USED. INSTALL ELECTRIC CHARGING STATION. REFER TO MEP PLANS. 12 2,185 SFSF OF NON-SERVICE AREA 6 SPACES TOTAL PROVIDED PARKING 49 SPACES REQUIRED HANDICAP PARKING CONTRACTOR SHALL REPAIR AND/OR REPLACE ANY DAMAGED AREAS OF PAVEMENT DUE TO CONSTRUCTION ACTIVITIES. HEAVY DUTY CONCRETE C-1 COMMUNITY AND HIGHWAY SERVICE COMMERCIAL DISTRICT FRONT BUILDING SETBACK - 30 FEET REAR BUILDING SETBACK - 30 FEET SIDE BUILDING SETBACK - NO MINIMUM, EXCEPT WHEN ADJACENT TO ANY R DISTRICT, THE MINIMUM SIDE YARD SETBACK SHALL BE 30 FEET. MAXIMUM HEIGHT - NO MINIMUM EXCEPT WHEN ADJACENT TO AN R-1, R-2 OR R-4 DISTRICT, THE MAXIMUM SHALL BE 2 STORIES OR 40 FEET 1 STORY OR 14 FEET FOR ACCESSORY BUILDING 13 FIRE LANE STRIPING: CONTRACTOR SHALL PICK UP DEBRIS SPILLED ONTO THE STREET AT THE END OF EACH WORKDAY AND PRIOR TO A RAIN EVENT. 14 ALL PROPOSED SIGNAGE IS REVIEWED UNDER A SEPARATE REVIEW. 15 16 1. SITE CONDITIONS BASED UPON SURVEY SUBMITTED BY OWNER. THE CONTRACTOR SHALL FIELD VERIFY ALL HORIZONTAL AND VERTICAL LINES AND GRADES OF EXISTING UTILITIES PRIOR TO THE CONSTRUCTION OF IMPROVEMENTS. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY UPON DISCOVERING A DISCREPANCY BETWEEN THE CONTRACT DRAWINGS AND ACTUAL FIELD CONDITIONS. CONTACT ONE CALL: 1-800-292-8989. 2. THE CONTRACTOR MUST COORDINATE CONSTRUCTION WITH THE NECESSARY AUTHORITIES. 3. APPLICABLE PERMITS MUST BE OBTAINED PRIOR TO EXCAVATION WITHIN ANY RIGHT-OF-WAY, AND PRIOR TO ANY CONSTRUCTION. 4. PROVIDE POSITIVE DRAINAGE AWAY FROM ALL BUILDINGS WITHOUT PONDING ON PARKING LOTS OR SIDEWALKS. ALL IMPROVED RUNOFF TO DRAIN TO DRAINWAYS. 5. ALL CONTOURS AND SPOT ELEVATIONS SHOWN ARE FINISH GRADE. 6. THE REMOVAL OF ANY TREES SHALL BE APPROVED BY THE PROJECT MANAGER PRIOR TO REMOVAL. 7. COORDINATE WORK WITH OTHER SITE RELATED DEVELOPMENT DRAWINGS. 8. TESTING OF CONTROLLED STRUCTURAL FILL, OBSERVATION OF EXCAVATIONS AND COMPACTION OF SUBGRADE SHALL BE DONE BY A QUALIFIED GEOTECHNICAL ENGINEER. FOLLOW GEOTECHNICAL ENGINEER RECOMMENDATIONS FOR SITE EXCAVATION REQUIREMENTS. 10. REFER TO STRUCTURAL DRAWINGS FOR BUILDING EXCAVATION REQUIREMENTS. 11. GRADING AT HANDICAP ACCESSIBLE PARKING SPACES SHALL NOT EXCEED 2% IN ANY DIRECTION. GRADING AT HANDICAP ACCESSIBLE ROUTE SHALL NOT EXCEED 5% IN DIRECTION OF TRAVEL WITH 2% MAXIMUM CROSS SLOPE. GRADING AT BUILDING EGRESS DOORS SHALL NOT EXCEED 2% FOR A DISTANCE OF 5'-0" PERPENDICULAR FROM FACE OF DOOR. 12. REFER TO PROJECT MANUAL FOR ADDITIONAL REQUIREMENTS. GENERAL NOTES: 1 CITY COMMENTS 06/27/2022 17 18 2 CITY COMMENTS 07/25/2022 3 CITY COMMENTS 08/09/2022 4 CITY COMMENTS 08/23/2022 5 CITY COMMENTS 09/06/2022 6 CITY COMMENTS 09/15/2022 8 CITY COMMENTS 10/24/2022 8 Digitally signed by Jared Davis, PE DN: C=US, E=jmdavis@andersonengineeringinc.com, O="Anderson Engineering, Inc", OU=VP, CN="Jared Davis, PE" Date: 2022.10.27 14:21:08-05'00' DRAWING INFORMATION PROJECT NO: ISSUED FOR: CHECK BY: DRAWN BY: SHEET NUMBER ENGINEERS · SURVEYORS LABORATORIES · DRILLING 3213 S WEST BYPASS SPRINGFIELD, MO 65807 PHONE (417) 866-2741 SHEET TITLE DATEDESCRIPTIONNO. ISSUED FOR ISSUED BY: LICENSE NO: ISSUED DATE: GERBER COLLISION & GLASS WILLIAMS POINTE WAUKEE, IA CMH JMD JARED M. DAVIS PE No. P25497 A LICENSED MISSOURI ENGINEERING CORPORATION COA 00062 22SP10014 PERMIT 06/07/2022 EXP: 12/31/2022 C1.1 SITE DETAILS STANDARD DUTY CONCRETE COMPACTED SUBGRADE 4" BASE ROCK (TYPE 1) PROVIDE CONTROL JOINTS AT 10' O.C. (25% SLAB THICKNESS) 6" CONCRETE PAVING (STANDARD DUTY) 8" CONCRETE PAVING (HEAVY DUTY)HEAVY DUTY: PROVIDE 8" CONCRETE PAVING SECTION FOR TRASH PAD AREA. STANDARD DUTY CONCRETE PAVEMENT SCALE: NOT TO SCALE 6 C1.1 GENERAL NOTES: 1. SUBGRADE MUST BE STABLE AND HARD UNDER PROOF ROLLING WITH A FULLY LOADED TANDEM AXLE DUMP TRUCK PRIOR TO INSTALLING BASE ROCK. 2. SOILS MUST BE PLACED AND COMPACTED TO A MINIMUM OF 95% MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D698 WITH MAXIMUM LOOSE LIFT OF 8". 3. THE MAXIMUM COMPACTED THICKNESS OF ANY ONE LAYER OF BASE ROCK MATERIAL SHALL NOT EXCEED 6 INCHES WITH EACH LIFT COMPACTED TO 100% OF MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D698 (STANDARD PROCTOR). 4. CONCRETE PAVEMENTS SHOULD MEET THE REQUIREMENTS OF THE 2020 WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND 2022 SUDAS. 5. CARE MUST BE TAKEN TO DEVELOP POSITIVE DRAINAGE ACROSS AND FROM AROUND THE PAVEMENT EDGES. WATER ALLOWED TO POND ON OR ADJACENT TO PAVEMENTS WOULD INCREASE THE POTENTIAL FOR MOISTURE INTRUSION INTO THE SUBGRADE SOILS AND COULD RESULT IN PREMATURE PAVEMENT FAILURE. 6. A MAINTENANCE PROGRAM THAT INCLUDES SURFACE SEALING, JOINT CLEANING AND SEALING AND TIMELY REPAIR OF CRACKS AND DETERIORATED AREAS WILL HELP PRESERVE THE PAVEMENT LIFE. 7. 28 DAY COMPRESSIVE STRENGTH TO BE 4000 PSI. 8. THE BASE ROCK SHOULD MEET THE REQUIREMENTS OF THE 2020 WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND 2022 SUDAS. TURNDOWN SIDEWALK DETAIL SCALE: NOT TO SCALE 5 C1.1 20" 20 " 12" SI D E W A L K 12 ' - 0 " T O 5" 10" 5" 5" 1. SYMBOL TO BE PAINTED (HIGHWAY GRADE) YELLOW PER ACCESSIBILITY STANDARDS. 5" 18" 6" 5" 1'-0" 6' - 0 " ACCESSIBLE PARKING SIGNAGE: "ACCESSIBLE PARKING" EQUAL TO "BEST" No. SS53. AT RIGHT HAND DISCHARGE LOCATION PROVIDE "VAN ACCESSIBLE" SIGNAGE EQUAL TO "BEST" No. SS57. ATTACH EA. SIGN TO BOLLARDS W/ GALV. MOUNTING BOLTS. SIGN MUST MEET CITY OF WAUKEE CODE SECTION 355.100. 1-1/2" DIAMETER GALVANIZED POLE SET INSIDE CONCRETE FOOTING. $50 TO $300 FINE PROVIDE CONTROL JOINTS AT 10' O.C. (25% SLAB THICKNESS) SCALE: NOT TO SCALE 3 C1.1 HANDICAP PARKING SIGNAGE POLE MOUNTED 2' - 0 " 0' - 6 " 0'-8" CONCRETE FOOTING. SCALE: NOT TO SCALE 1 C1.1 CURB AND GUTTER SECTION SCALE: NOT TO SCALE 2 C1.1 H.C. PARKING SYMBOL SCALE: NOT TO SCALE 7 C1.1 BICYCLE PARKING DETAIL 24" 72 " PARKING PAD 24" INVERTED U BIKE RACK 30 " 24" 4" THICK CONCRETE SIDEWALK 4" TYPE 1 AGGREGATE EXTEND 6" PAST EDGE OF SIDEWALK COMPACTED SUB GRADE NOTE: 1. ALL SIDEWALKS ARE TO BE BUILT PER CITY OF WAUKEE STANDARDS. 2. CONTROL JOINTS AT 5'-0"' O.C. 2% MAX. CROSS-SLOPE SCALE: NOT TO SCALE 4 C1.1 SIDEWALK CROSS SECTION STANDARD DUTY CONCRETE COMPACTED SUBGRADE 4" BASE ROCK (TYPE 1) PROVIDE CONTROL JOINTS AT 10' O.C. (25% SLAB THICKNESS) 8" CONCRETE PAVING (HEAVY DUTY) HEAVY DUTY CONCRETE PAVEMENT SCALE: NOT TO SCALE 8 C1.1 GENERAL NOTES: 1. SUBGRADE MUST BE STABLE AND HARD UNDER PROOF ROLLING WITH A FULLY LOADED TANDEM AXLE DUMP TRUCK PRIOR TO INSTALLING BASE ROCK. 2. SOILS MUST BE PLACED AND COMPACTED TO A MINIMUM OF 95% MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D698 WITH MAXIMUM LOOSE LIFT OF 8". 3. THE MAXIMUM COMPACTED THICKNESS OF ANY ONE LAYER OF BASE ROCK MATERIAL SHALL NOT EXCEED 6 INCHES WITH EACH LIFT COMPACTED TO 100% OF MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D698 (STANDARD PROCTOR). 4. CONCRETE PAVEMENTS SHOULD MEET THE REQUIREMENTS OF THE 2020 WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND 2022 SUDAS. 5. CARE MUST BE TAKEN TO DEVELOP POSITIVE DRAINAGE ACROSS AND FROM AROUND THE PAVEMENT EDGES. WATER ALLOWED TO POND ON OR ADJACENT TO PAVEMENTS WOULD INCREASE THE POTENTIAL FOR MOISTURE INTRUSION INTO THE SUBGRADE SOILS AND COULD RESULT IN PREMATURE PAVEMENT FAILURE. 6. A MAINTENANCE PROGRAM THAT INCLUDES SURFACE SEALING, JOINT CLEANING AND SEALING AND TIMELY REPAIR OF CRACKS AND DETERIORATED AREAS WILL HELP PRESERVE THE PAVEMENT LIFE. 7. 28 DAY COMPRESSIVE STRENGTH TO BE 4000 PSI. 8. THE BASE ROCK SHOULD MEET THE REQUIREMENTS OF THE 2020 WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND 2022 SUDAS. 1 CITY COMMENTS 06/27/2022 2 CITY COMMENTS 07/25/2022 3 3 CITY COMMENTS 08/09/2022 Digitally signed by Jared Davis, PE DN: C=US, E=jmdavis@andersonengineeringinc.com, O="Anderson Engineering, Inc", OU=VP, CN="Jared Davis, PE" Date: 2022.08.09 14:58:42-05'00' 1048 1047 1046 1045 1045 1046 1047 1048 K D R I V E GR A D E B R E A K GR A D E B R E A K GR A D E B R E A K 4.0% 2. 5 % 2.2 % 2.0 % 2.0 % 3.5 % 2.2% 2.2% 2.0% 2.0% 2.0% 2.0% 1.0% 1. 0 % 1.0% 1.4% 2.5 % 2.8% 3.5% 1.0% GRADE BREAK 2.0% 1.0% 1 . 0 % 2 . 4 % 1.0 % 1.5% 2.5% 3 . 2 % SE B R I C K D R I V E GRADE B R E A K 10 5 5 1054 1054 1051 10 4 9 1 0 5 5 105 4 1054 1055 1055 10 5 5 10 5 5 1055 10 5 4 10 5 4 10 5 4 1055 1054 10521051 1057 1055 1055 1055 105 0 1049 105 0 1 0 5 2 1 0 5 1 1 0 5 3 1052 1053 1056 1053 1055 1055 10 4 6 10 4 5 10 4 4 10 4 3 10 4 2 10 4 1 10 4 0 1040104110421043104410451046 10 5 1 10 5 2 10 5 3 10 5 4 1051 10 5 4 10 5 1 10 4 9 10 5 3 10 4 6 3:1 3: 1 3:1 3:1 4:1 4:1 4.2% 1.5 % 0.0 % 0.0 % 10 4 7 51051050505 5005050 1.0 % 0% 1.0 % 0% 1.0% 1.0 % 1.0% 1.0 % 1.0 % 0% 1.0 % 0% 0% 1.5 % 4.0% 1052 10 5 0 1050 10 5 0 10 5 0 1 0 5 0 5.0% 1.0 % 5 . 0 % 2.5 % 1.1% 1. 0 % 1. 0 % 1.0% 0. 0 % 1.0 % 1.1% 1.0 % 1. 0 % 0.0% 1.0% 0.0 % 1. 0 % SITE GRADING PLAN SCALE: 1" = 30' 1 C2 TOTAL PROPERTY AREA = 2.0 ACRES TOTAL DISTURBED AREA = 2.2 ACRES > 1.0 ACRES, THEREFORE A LAND DISTURBANCE PERMIT IS REQUIRED DETENTION IS PROVIDED TO REDUCE ALL DEVELOPED FLOWS FOR ALL STORMS ABOVE THE 5-YEAR STORM TO THE EXISTING 5-YEAR FLOW RATE. 1. PIPE MATERIALS SHALL BE IN ACCORDANCE WITH THE 2020 WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND THE 2022 STATEWIDE URBAN DESIGN AND SPECIFICATIONS (SUDAS). 2. ALL PIPE IS TO BE INSTALLED PER THE MANUFACTURER'S REQUIREMENTS AND MEET COVER REQUIREMENTS PER THE MANUFACTURER. REFER TO MANUFACTURER FOR MATERIAL SPECIFICATIONS FOR TRAFFIC LOADING AND INSTALLATION REQUIREMENTS. PIPES NOTES: 1. IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. 2. THE DUTY OF THE ENGINEER OR OWNER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES IN, ON, OR NEAR THE CONSTRUCTION SITE. SAFETY NOTES:GENERAL NOTES: 1. SITE CONDITIONS BASED UPON SURVEY SUBMITTED BY OWNER. THE CONTRACTOR SHALL FIELD VERIFY ALL HORIZONTAL AND VERTICAL LINES AND GRADES OF EXISTING UTILITIES PRIOR TO THE CONSTRUCTION OF IMPROVEMENTS. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY UPON DISCOVERING A DISCREPANCY BETWEEN THE CONTRACT DRAWINGS AND ACTUAL FIELD CONDITIONS. CONTACT ONE CALL: 1-800-344-7483. 2. THE CONTRACTOR MUST COORDINATE CONSTRUCTION WITH THE NECESSARY AUTHORITIES. 3. APPLICABLE PERMITS MUST BE OBTAINED PRIOR TO EXCAVATION WITHIN ANY RIGHT-OF-WAY, AND PRIOR TO ANY CONSTRUCTION. 4. PROVIDE POSITIVE DRAINAGE AWAY FROM ALL BUILDINGS WITHOUT PONDING ON PARKING LOTS OR SIDEWALKS. 5. ALL DEVELOPED RUNOFF TO DRAIN TO DRAINWAYS. 6. ALL CONTOURS AND SPOT ELEVATIONS SHOWN ARE FINISH GRADE. 7. THE REMOVAL OF ANY TREES SHALL BE APPROVED BY THE PROJECT MANAGER PRIOR TO REMOVAL. 8. COORDINATE WORK WITH OTHER SITE RELATED DEVELOPMENT DRAWINGS. 9. TESTING OF CONTROLLED STRUCTURAL FILL, OBSERVATION OF EXCAVATIONS AND COMPACTION OF SUBGRADE SHALL BE DONE BY A QUALIFIED GEOTECHNICAL ENGINEER. FOLLOW GEOTECHNICAL ENGINEER RECOMMENDATIONS FOR SITE EXCAVATION REQUIREMENTS. 10.REFER TO STRUCTURAL DRAWINGS FOR BUILDING EXCAVATION REQUIREMENTS. 11.GRADING AT HANDICAP ACCESSIBLE PARKING SPACES SHALL NOT EXCEED 2% IN ANY DIRECTION. GRADING AT HANDICAP ACCESSIBLE ROUTE SHALL NOT EXCEED 5% IN DIRECTION OF TRAVEL WITH 2% MAXIMUM CROSS SLOPE. GRADING AT BUILDING EGRESS DOORS SHALL NOT EXCEED 2% FOR A DISTANCE OF 5'-0" PERPENDICULAR FROM FACE OF DOOR. FIELD VERIFY SANITARY SEWER AND STORM SEWER CONNECTION INVERT PRIOR TO ESTABLISHING FINAL FINISH FLOOR ELEVATION. REFER TO SITE UTILITIES PLAN. EXISTING SURFACE FEATURES, STRUCTURES, ETC. AND UNDERGROUND INSTALLATIONS SUCH AS WATER MAINS, GAS MAINS, SEWERS, TELEPHONE LINES, FIBER OPTIC LINES AND BURIED STRUCTURES ARE INDICATED ON THE DRAWING ONLY TO THE EXTENT SUCH INFORMATION HAS BEEN MADE AVAILABLE TO OR DISCOVERED BY THE SURVEYOR IN PREPARING THIS DRAWING. THERE IS NO GUARANTEE AS TO THE ACCURACY OR COMPLETENESS OF SUCH INFORMATION. THE CONTRACTOR IS RESPONSIBLE FOR MAKING HIS OWN DETERMINATION AS TO THE TYPE AND LOCATION OF UNDERGROUND AND OTHER UTILITIES AS MAY BE NECESSARY TO AVOID DAMAGE THERETO. CAUTION: CONTRACTOR TO PERFORM DETAILED SITE INSPECTION TO LOCATE ALL EXISTING UTILITES AND VERIFY ANY POSSIBLE CONFLICTS WITH PROPOSED IMPROVEMENTS PRIOR TO BEGINNING ANY CONSTRUCTION. CONTACT ENGINEER WITH ANY CONFLICTS. CONTRACTOR SHALL FIELD VERIFY PROPOSED GRADES MATCH EXISTING PAVEMENT AT DRIVEWAY ENTRANCES, SIDEWALK CONNECTIONS, AND ALL CONNECTION POINTS PRIOR TO BEGINNING CONSTRUCTION. CONTRACTOR SHALL NOTIFY ENGINEER IF DISCREPANCY OCCURS. DRAWING INFORMATION PROJECT NO: ISSUED FOR: CHECK BY: DRAWN BY: SHEET NUMBER ENGINEERS · SURVEYORS LABORATORIES · DRILLING 3213 S WEST BYPASS SPRINGFIELD, MO 65807 PHONE (417) 866-2741 SHEET TITLE DATEDESCRIPTIONNO. ISSUED FOR ISSUED BY: LICENSE NO: ISSUED DATE: GERBER COLLISION & GLASS WILLIAMS POINTE WAUKEE, IA CMH JMD JARED M. DAVIS PE No. P25497 A LICENSED MISSOURI ENGINEERING CORPORATION COA 00062 22SP10014 PERMIT 06/07/2022 EXP: 12/31/2022 C2 SITE GRADING AND STORM SEWER PLAN 1055 EXISTING GRADE LINES PROPOSED NEW GRADE LINES +105 5 . 0 P V T 1. A GEOTECHNICAL ANALYSIS HAS BEEN PERFORMED ON THIS SITE. REFER TO PROJECT MANUAL. 2. FOLLOW GEOTECHNICAL ANALYSIS RECOMMENDATION FOR SITE EXCAVATION. 3. REFER TO STRUCTURAL DRAWINGS FOR BUILDING EXCAVATION REQUIREMENTS. SITE EXCAVATION REQUIREMENTS: SPECIAL NOTE: ALL WORK DONE ON THE PROJECT SHALL BE IN CONFORMANCE WITH 2020 WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND 2022 SUDAS. CITY OF WAUKEE NOTES AS-BUILT PLANS OF ALL STORM WATER MANAGEMENT FACILITIES ON SITE AND A CERTIFICATION STATEMENT SIGNED BY SWPPP DESIGNER INDICATING THAT FACILITIES WERE CONSTRUCTED AS DESIGNED WILL BE REQUIRED. RECEIVING WATER: UNNAMED TRIBUTARY TO SUGAR CREEKSTAGES OF CONSTRUCTION: 1. CONTACT THE CITY OF WAUKEE PUBLIC WORKS 48 HRS PRIOR TO CONSTRUCTION. 2. CONTRACTOR TO PERFORM DETAILED SITE INSPECTION TO LOCATE ALL EXISTING UTILITIES AND VERIFY ANY POSSIBLE CONFLICTS WITH PROPOSED IMPROVEMENTS PRIOR TO BEGINNING ANY CONSTRUCTION. CONTACT OWNER WITH ANY CONFLICTS. MONTH 1 3. INSTALLATION OF CONSTRUCTION ENTRANCE. MONTH 1 4. INSTALLATION OF EROSION & SEDIMENT CONTROL FENCE. MONTH 1 5. DEMOLITION OF EXISTING SITE IMPROVEMENTS. MONTH 1 6. REMOVAL OF EXISTING PAVEMENT ON THE SITE. MONTH 1 7. INSTALLATION OF ALL STORM WATER DRAINAGE IMPROVEMENTS. MONTH 1 8. ROUGH GRADING. MONTH 1 & MONTH 2 9. CONSTRUCTION OF NEW SITE IMPROVEMENTS. MONTH 2 10. FINAL GRADING. MONTH 3 11. PLACEMENT OF FINAL LANDSCAPING ITEMS AND SOD. MONTH 3 12. CONTACT THE CITY OF WAUKEE PUBLIC WORKS FOR FINAL INSPECTION FOR CLOSE OUT. MONTH 3 13. REMOVAL OF EROSION & SEDIMENT CONTROL FENCE. MONTH 3 KEY NOTES: HANDICAP PARKING AREA. REFER TO DETAIL 2/C2. INSTALL OPEN-SIDED AREA INTAKE, OPEN ON ALL SIDES. RIM = 1053.0' INV = 1050.5' REFER TO DETAIL 1/C2.1. ADA PARKING DETAIL SCALE: 1"=10' 2 C2 HANDICAP AREA TO BE ADA COMPLIANT. SLOPES SHALL NOT EXCEED 2.0% IN ANY DIRECTION IN THIS AREA. NOT USED. NOT USED. 130 LF OF 18"Ø HDPE PIPE @ 1.0%. REFER TO PIPE NOTES. INSTALL OPEN-SIDED AREA INTAKE, OPEN ON ALL SIDES. RIM = 1053.0' INV = 1049.2' REFER TO DETAIL 1/C2.1. 289 LF OF 18"Ø HDPE PIPE @ 1.0%. REFER TO PIPE NOTES. INSTALL OPEN-SIDED AREA INTAKE, OPEN ON ALL SIDES. RIM = 1050.0' INV = 1046.3' REFER TO DETAIL 1/C2.1. 47 LF OF 24"Ø HDPE PIPE @ 1.0%. REFER TO PIPE NOTES. DETENTION OUTLET STRUCTURE. REFER TO DETAIL 2/C2.1. 5 LF OF 18"Ø HDPE PIPE @ 2.9% WITH HDPE FLARED END SECTION. DAYLIGHT IN BASIN @ 1046.2'. REFER TO PIPE NOTES. ALL RIP-RAP SHALL BE CLASS D REVETMENT STONE IN ACCORDANCE WITH SECTION 4130 AND 7E-10 OF THE 2022 SUDAS. RIP-RAP NOTE: INSTALL SINGLE OPEN-THROAT CURB INTAKE, LARGE BOX RIM = 1050.2' THROAT = 1049.45' INV = 1046.4' REFER TO DETAIL 3/C2.1. 25 LF OF 18"Ø HDPE PIPE @ 1.2%. REFER TO PIPE NOTES. INSTALL SINGLE OPEN-THROAT CURB INTAKE, LARGE BOX RIM = 1050.2' THROAT = 1049.45' INV = 1046.7' REFER TO DETAIL 3/C2.1. 65 LF OF 18"Ø HDPE PIPE @ 1.0% WITH HDPE FLARED END SECTION. DISCHARGE STORMPIPE TO SWALE PROVIDED BY THE DEVELOPER @ INV = 1045.5' . REFER TO PLANS PREPARED BY THE DEVELOPER'S ENGINEER. APPROVED FIRE APPARATUS ACCESS ROADS SHALL BE PROVIDED AS SOON AS CONSTRUCTION COMMENCES. IF PAVING IS NOT INSTALLED PRIOR TO BUILDING CONSTRUCTION COMMENCING AFTER FOOTINGS ARE INSTALLED, AN APPROVED ROUTE AROUND THE EXTERIOR OF THE BUILDING TO EXTEND WITHIN 100-FEET OF ALL PORTIONS OF THE EXTERIOR WALLS SHALL BE PROVIDED AND COMPLY WITH THE REQUIREMENTS OF SECTION 503.2 OF THE IFC. FIRE SAFETY CONSTRUCTION NOTE: ALL STORM SEWERS SHALL BE TELEVISED & CLEANED AS NEEDED OR REQUIRED BY THE CITY OF WAUKEE. 1 CITY COMMENTS 06/27/2022 2 CITY COMMENTS 07/25/2022 INSTALL 355 LF OF 2.0' HIGH LANDSCAPE BLOCK WALL. GD UP=1049.0', GD DOWN=1047.0'. REFER TO DETAIL 1/C2.2. INSTALL ADS STORMTECH SYSTEM PER ADS PLANS "BED 1". REFER TO PLANS PREPARED BY ADS. INSTALL ADS STORMTECH SYSTEM PER ADS PLANS "BED 2". REFER TO PLANS PREPARED BY ADS. INSTALL RECTANGULAR AREA INTAKE W/ 24" SUMP AND CONNECT TO STORMTECH SYSTEM "BED 1". RIM=1050.3' INV=1045.8' REFER TO DETAIL 3/C2.2. INSTALL 5'X5' WATER QUALITY STRUCTURE. RIM=1051.6' INV=1045.0' REFER TO DETAIL 4/C2.2. INSTALL RECTANGULAR AREA INTAKE W/ 24" SUMP AND CONNECT TO STORMTECH SYSTEM "BED 2". RIM=1054.0' INV=1048.5' REFER TO DETAIL 3/C2.2. 21 LF OF 24"Ø HDPE PIPE @ 1.0% WITH HDPE FLARED END SECTION. DAYLIGHT IN BASIN @ 1044.8'. REFER TO PIPE NOTES. INSTALL 5'X5' WATER QUALITY STRUCTURE. RIM=1054.2' INV=1048.3' REFER TO DETAIL 2/C2.2. 25 LF OF 18"Ø HDPE PIPE @ 2.8% WITH HDPE FLARED END. DAYLIGHT IN BASIN @ 1047.6'. REFER TO PIPE NOTES. 3 CITY COMMENTS 08/09/2022 CONTACT MARK VITTORI (630) 854-8781 AT ADS FOR PLANS AND SPECIFICATIONS. NOTE: CONTRACTOR SHALL SEND SHOP DRAWINGS OF ADS UNITS TO ANDERSON ENGINEERING FOR APPROVAL PRIOR TO BEGINNING CONSTRUCTION. 3 LF OF 18"Ø HDPE PIPE @3.3%. REFER TO PIPE NOTES. 100-YEAR STORM PONDING AREA. REFER TO SHEET C6 FOR ELEVATIONS. 4 CITY COMMENTS 08/23/2022 5 CITY COMMENTS 09/06/2022 6 CITY COMMENTS 09/15/2022 7 CITY COMMENTS 10/03/2022 8 8 CITY COMMENTS 10/24/2022 8 8 Digitally signed by Jared Davis, PE DN: C=US, E=jmdavis@andersonengineeringinc.com, O="Anderson Engineering, Inc", OU=VP, CN="Jared Davis, PE" Date: 2022.10.27 14:21:43-05'00' DRAWING INFORMATION PROJECT NO: ISSUED FOR: CHECK BY: DRAWN BY: SHEET NUMBER ENGINEERS · SURVEYORS LABORATORIES · DRILLING 3213 S WEST BYPASS SPRINGFIELD, MO 65807 PHONE (417) 866-2741 SHEET TITLE DATEDESCRIPTIONNO. ISSUED FOR ISSUED BY: LICENSE NO: ISSUED DATE: GERBER COLLISION & GLASS WILLIAMS POINTE WAUKEE, IA CMH JMD JARED M. DAVIS PE No. P25497 A LICENSED MISSOURI ENGINEERING CORPORATION COA 00062 22SP10014 PERMIT 06/07/2022 EXP: 12/31/2022 C2.1 STORM SEWER STRUCTURE DETAILS OPEN SIDED AREA INTAKE SCALE: NTS 1 C2.1 SINGLE OPEN-THROAT CURB INTAKE, LARGE BOX SCALE: NTS 3 C2.1 1 CITY COMMENTS 06/27/2022 2 CITY COMMENTS 07/25/2022 GENERAL NOTES: 1. ALL EXPOSED CORNERS TO HAVE 3/4" CHAMFER 2. ALL #4 & #5 REINFORCING BARS TO HAVE 1-1/2" COVER, LARGER SIZES TO HAVE 2" COVER. 3. PIPES SHALL CONNECT TO THE ENDS OR SIDES OF THE INLET. CONNECTION SHALL NOT BE MADE AT THE CORNERS OF THE INLET. 4. ALL REINFORCING BARS TO BE GRADE 60. DETENTION OUTLET STRUCTURE SCALE: NOT TO SCALE 2 C2.1 4 CITY COMMENTS 08/23/2022 5 CITY COMMENTS 09/06/2022 6 CITY COMMENTS 09/15/2022 8 8 CITY COMMENTS 10/24/2022 Digitally signed by Jared Davis, PE DN: C=US, E=jmdavis@andersonengineeringinc.com, O="Anderson Engineering, Inc", OU=VP, CN="Jared Davis, PE" Date: 2022.10.27 14:21:23-05'00' DRAWING INFORMATION PROJECT NO: ISSUED FOR: CHECK BY: DRAWN BY: SHEET NUMBER ENGINEERS · SURVEYORS LABORATORIES · DRILLING 3213 S WEST BYPASS SPRINGFIELD, MO 65807 PHONE (417) 866-2741 SHEET TITLE DATEDESCRIPTIONNO. ISSUED FOR ISSUED BY: LICENSE NO: ISSUED DATE: GERBER COLLISION & GLASS WILLIAMS POINTE WAUKEE, IA CMH JMD JARED M. DAVIS PE No. P25497 A LICENSED MISSOURI ENGINEERING CORPORATION COA 00062 22SP10014 PERMIT 06/07/2022 EXP: 12/31/2022 C2.2 GRADING PLAN AND STRUCTURE DETAILS 07/25/2022 RECTANGULAR AREA INTAKE SCALE: NTS 3 C2.2 MODULAR BLOCK RETAINING WALL SCALE: NTS 1 C2.2 "BED 2" 5'X5' WATER QUALITY STRUCTURE SCALE: NTS 2 C2.2 NOTE: INSTALL UNDERDRAIN FROM STORMTECH SYSTEM TO DOWNSTREAM SIDE OF WEIR. REFER TO PLANS PREPARED BY ADS. UNDERDRAIN NOTE: NOTE: CONTRACTOR TO USE GRATE WITH A MIN. OPENING AREA OF 4.0 SFT. REQUIRED OPENING: "BED 1" 5'X5' WATER QUALITY STRUCTURE SCALE: NTS 4 C2.2 3 CITY COMMENTS 08/09/2022 4 CITY COMMENTS 08/23/2022 4 Digitally signed by Jared Davis, PE DN: C=US, E=jmdavis@andersonengineeringinc.com, O="Anderson Engineering, Inc", OU=VP, CN="Jared Davis, PE" Date: 2022.08.23 17:06:42-05'00' 1048 1047 1046 1045 1045 1046 1047 1048 K D R I V E SE B R I C K D R I V E 10 5 5 1054 1054 1051 10 4 9 1 0 5 5 105 4 1054 1055 1055 10 5 5 10 5 5 1055 10 5 4 10 5 4 10 5 4 1055 1054 10521051 1057 1055 1055 1055 105 0 1049 105 0 1 0 5 2 1 0 5 1 1 0 5 3 1052 1053 1056 1053 1055 1055 10 4 6 10 4 5 10 4 4 10 4 3 10 4 2 10 4 1 10 4 0 1040104110421043104410451046 10 5 1 10 5 2 10 5 3 10 5 4 1051 10 5 4 10 5 1 10 4 9 10 5 3 10 4 6 10 4 7 1052 10 5 0 1050 10 5 0 10 5 0 1 0 5 0 EROSION & SEDIMENT CONTROL PLAN SCALE: 1" = 30' 1 C3 DRAWING INFORMATION PROJECT NO: ISSUED FOR: CHECK BY: DRAWN BY: SHEET NUMBER ENGINEERS · SURVEYORS LABORATORIES · DRILLING 3213 S WEST BYPASS SPRINGFIELD, MO 65807 PHONE (417) 866-2741 SHEET TITLE DATEDESCRIPTIONNO. ISSUED FOR ISSUED BY: LICENSE NO: ISSUED DATE: GERBER COLLISION & GLASS WILLIAMS POINTE WAUKEE, IA CMH JMD JARED M. DAVIS PE No. P25497 A LICENSED MISSOURI ENGINEERING CORPORATION COA 00062 22SP10014 PERMIT 06/07/2022 EXP: 12/31/2022 C3 EROSION & SEDIMENT CONTROL PLAN SPECIAL NOTE: CONTRACTOR TO PROVIDE WASTE DISPOSAL AND SOIL STOCK PILING ON SITE. EROSION CONTROL QUANTITIES ITEM QUANTITY SILT SOCKS 1350 LF CONC WASH 1 STOCKPILE 1 RIP RAP 90 SYD - APPROX. 79 TONS TRASH AND WASTE NOTE: CONTRACTOR TO PROVIDE WASTE CONTAINMENT INCLUDING TRASH COLLECTION AND CONCRETE WASHOUT.TEMP SEEDING 36,000 SQ FT - 30 lbs / acre TYPE 2 TRM 15 SYD EROSION CONTROL & MAINTENANCE PLAN NOTES: 1. CONTRACTOR TO RETAIN FLOATABLE WIND BLOWN MATERIALS ON SITE BY STORING ALL TRASH AND BUILDING MATERIAL WASTE IN ENCLOSURES UNTIL PROPER DISPOSAL AT OFF-SITE FACILITIES. CHECK ADJACENT AREAS DAILY AND PICK UP CONSTRUCTION WASTE MATERIALS AND DEBRIS THAT HAVE BLOWN OR WASHED OFF SITE. 2. PERMANENTLY STABILIZE ALL SURFACE AREA WITHIN AND ADJACENT TO THIS SITE THAT IS DISTURBED BY VEHICLES, GRADING AND OTHER CONSTRUCTION FOR THE PROPOSED FACILITY. STABILIZATION IS OBTAINED WHEN THE DISTURBED SURFACE IS COVERED WITH STRUCTURES, PAVING AND OR PERENNIAL VEGETATION HAVING A UNIFORM COVERAGE DENSITY OF AT LEAST 70%. STABILIZATION OF ALL DISTURBED AREA IS REQUIRED BEFORE TERMINATING MAINTENANCE AND REMOVAL OF EROSION CONTROL MEASURES. 3. CONTRACTORS SHALL INSPECT POLLUTION CONTROL MEASURES AT LEAST ONCE EVERY 7 DAYS AND WITHIN 24 HOURS AFTER A STORM EVENT OF 1/2 INCH OR GREATER. DAMAGED MEASURES THAT PROVE TO BE INEFFECTIVE SHALL BE REPLACED WITH MORE EFFECTIVE MEASURES OR ADDITIONAL MEASURES WITHIN SEVEN DAYS. REPEATED FAILURE OF A CONTROL MEASURE REQUIRES INSTALLATION OF A MORE SUITABLE DEVICE TO PREVENT DISCHARGE OF POLLUTANTS FROM THE CONSTRUCTION SITE. 4. INSTALLATION OF ADDITIONAL EROSION CONTROL MEASURES MAY BE REQUIRED BY THE CITY OR STATE. CONTRACTOR TO VERIFY REQUIREMENTS PRIOR TO BEGINNING ANY WORK ON PROJECT SITE. 5. CARE SHALL BE TAKEN TO ELIMINATE TO THE MAXIMUM EXTENT POSSIBLE THE ENCROACHMENT OF SEDIMENT INTO ALL STORM DRAIN APPURTENANCES, PUBLIC STREETS, AND ONTO PRIVATE PROPERTY UNTIL IMPERVIOUS MATERIAL (ROAD/PARKING AREA SURFACE) IS APPLIED OR UNTIL PROPOSED LANDSCAPE HAS BEEN ESTABLISHED. 6. REMOVE SEDIMENT DEPOSITS AS NECESSARY AFTER EACH STORM TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. CARE NEEDS TO BE TAKEN TO AVOID UNDERMINING THE FENCE WHEN REMOVING SEDIMENT. SEDIMENT IS TO BE REAPPLIED TO THE SITE AND STABILIZED. 7. ALL GRASS SLOPES WHICH EXCEED 3:1 (H:V) AND SELECT PIPE OUTFALLS SHALL UTILIZE CONTECH CONSTRUCTION PRODUCTS PERMANENT TURF REINFORCEMENT MATS 450 OR APPROVED EQUAL. MATS SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS AND STANDARDS. CONTRACTOR SHALL COORDINATE INSTALLATION INSPECTION WITH MANUFACTURER. 8. CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO THE 2020 WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND 2022 SUDAS. 9. APPLICABLE PERMITS MUST BE OBTAINED FROM THE CITY, STATE AND COUNTY PRIOR TO EXCAVATION WITHIN ANY RIGHT-OF-WAY, AND PRIOR TO ANY CONSTRUCTION. 10. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE LOCATION OF ANY UNDERGROUND UTILITIES OR OTHER OBSTRUCTIONS AND TO BE LIABLE FOR DAMAGE AND CONSEQUENT REPAIR TO SUCH IN THE COURSE OF HIS OPERATIONS. 11. THE CONTRACTOR AND/OR BUILDER WILL KEEP THE SUBDIVISION NEAT AND ORDERLY AT ALL TIMES WHILE CONSTRUCTION IS TAKING PLACE. ALL CITY STREETS ADJACENT TO THE DEVELOPMENT SHALL BE KEPT CLEAR OF MUD, ROCK, DIRT, DEBRIS, PAPER AND WASTE MATERIAL AT ALL TIMES. THE PROPER AMOUNT OF INSPECTION SHALL BE CALLED FOR AT THEIR PROPER TIMES, OR ANY AND ALL WORK MAY BE REJECTED. 12. IF ANY WORK OR ACCESS TO ANY ADJOINING PROPERTY IS DONE, IT IS THE FULL RESPONSIBILITY FOR THE APPLICANT/OWNER TO OBTAIN PROPER RELEASES FROM ADJOINING PROPERTY OWNERS AND ASSUME ALL LIABILITY FOR ACTION TAKEN DURING ALL CONSTRUCTION. 13. ALL DISTURBED AREAS ARE TO BE RESEEDED IN ACCORDANCE WITH THE 2020 WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND 2022 SUDAS. 14. PROVIDE TEMPORARY EROSION CONTROL TO CONTAIN ALL SOILS ON SITE. COMPLY WITH GOVERNING REGULATIONS PERTAINING TO ENVIRONMENTAL PROTECTION. 15. THE DETENTION BASIN, ALL WATER QUALITY MEASURES AND STORMWATER CHANNELS(PIPES) SHALL BE FUNCTIONING PRIOR TO STARTING ANY OTHER CONSTRUCTION ACTIVITIES. I.E., ONLY CONSTRUCTION ACTIVITIES REQUIRED TO INSTALL THE DETENTION BASIN, ALL WATER QUALITY MEASURES AND STORMWATER CHANNELS(PIPES) ARE ALLOWED UNTIL THESE ITEMS ARE INSTALLED AND APPROVED. 16. CONSTRUCTION ACCESS TO THE SITE SHALL BE LIMITED TO THE APPROVED TEMPORARY CONSTRUCTION ENTRANCE AS SHOWN ON THE STORMWATER POLLUTION PREVENTION PLAN. 17. EROSION CONTROL DEVICES SHALL BE MAINTAINED DURING THE WHOLE CONSTRUCTION PERIOD BY THE CONTRACTOR. 18. CONTRACTOR TO PROTECT ANY STORM INLETS THAT RECEIVE STORM WATER FROM THE AREA OF CONSTRUCTION FROM SEDIMENT. 19. CONTRACTOR TO TAKE CARE NOT TO DAMAGE ANY EXISTING STREET, CURB AND GUTTER, SIDEWALK AND DRIVEWAYS. 20. THE CONTRACTOR SHALL HAVE A SET OF PLANS FILED WITH THE CITY OF WAUKEE ON SITE. THE CONTRACTOR SHALL HAVE ON THE PROJECT AT ALL TIMES, AS HIS AGENT, A COMPETENT SUPERINTENDENT CAPABLE OF READING AND THOROUGHLY UNDERSTAND THE PLANS AND SPECIFICATIONS AND THOROUGHLY EXPERIENCE IN THE TYPE WORK BEING PERFORMED WHO SHALL RECEIVE INSTRUCTIONS FROM THE ENGINEER OR HIS AUTHORIZED REPRESENTATIVE. 21. THE CONTRACTOR SHALL NOTIFY THE INSPECTOR OF ANY NEW SINKHOLES DISCOVERED DURING CONSTRUCTION. 22. TEMPORARY CONSTRUCTION ENTRANCE TO HAVE SHOT ROCK FOR ITS SURFACE. 23. THE INSTALLATION OF SILT FENCE FOR CONSTRUCTION IS TO BE INSTALLED BY THE CONTRACTOR AND IN PLACE BEFORE BEGINNING SITE CONSTRUCTION. SIMILAR DEVICES MAY BE USED BY THE CONTRACTOR TO MEET THE REQUIREMENTS OF THE ENGINEER. DEVICES TO BE IN PLACE AS SHOWN ON THE PLANS. ADJUSTMENT OF THE LOCATION BY THE CONTRACTOR MAY BE DONE TO MEET EXISTING FIELD CONDITIONS. ALL CONTROLS ARE TO BE PLACED WITHIN OWNER'S PROPERTY. ACCUMULATED SEDIMENT IN BASINS WILL REQUIRE REMOVAL DURING CONSTRUCTION OR AFTER EACH RAIN EVENT AND AT THE END OF CONSTRUCTION. EACH BASIN SHALL BE CHECKED AFTER EACH RAIN EVENT. CONTRACTOR TO MINIMIZE THE AREA DISTURBED BY CONSTRUCTION ACTIVITIES AT ANY ONE TIME AND TO PROMPTLY REVEGETATE (OR MECHANICALLY STABILIZE) AREA DISTURBED BY CONSTRUCTION ACTIVITY. 24. SILT FENCE SHALL BE PLACED AROUND ALL SOIL SPOIL PILES TO PREVENT EROSION. SEEDING AND MULCHING NOTES REFER TO DETAIL 2/C3 FOR SEEDING TABLE AND SECTIONS 7E-24, 7E-22, AND 7E-17 OF THE 2022 SUDAS FOR SEEDING AND MULCHING REQUIRMENTS AND SPECIFICATIONS. LAND DISTURBANCE SUMMARY: TOTAL PROPERTY AREA= 2.2 ACRES TOTAL DISTURBED AREA = 2.3 ACRES A NOI IS REQUIRED AND WILL BE OBTAINED KEY NOTES: LIMITS OF LAND DISTURBANCE. PERMITTED DISTURBED AREA = 2.2 ACRES INSTALL 12" COMPOST FILTER SOCK OR APPROVED EQUAL. SEE DETAIL 1/C3.1. INSTALL TEMPORARY CONSTRUCTION ENTRANCE PER DETAIL 2/C3.1. AREAS TO BE VEGETATED: ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE RESTORED BY SOD. SEE SEEDING NOTES & DETAIL 2/C3. INSTALL 10' X 10' CONCRETE WASHOUT AREA. CONTRACTOR TO FIELD VERIFY LOCATION. SEE DETAIL 3/C3.1. INSTALL DUMPSTER AND CONTACT TRASH COMPANY FOR PICK UP. CONTRACTOR TO FIELD VERIFY LOCATION. INSTALL PORTABLE TOILET AND STAKE FIRMLY TO GROUND. CONTRACTOR TO FIELD VERIFY LOCATION. NOT USED. LOCATION OF OUTFALL 001. TEMPORARY STOCKPILE LOCATION TO BE SURROUNDED BY 12" COMPOST FILTER SOCK. FINAL LOCATION TO BE DETERMINED BY CONTRACTOR. INSTALL DETENTION OUTLET PROTECTION. REFER TO DETAIL 4/C3.1. INSTALL TYPE 2 TURF REINFORCEMENT MATT PER 2022 SUDAS AS GENERALLY SHOWN. PROTECT INLET WITH 12" COMPOST FILTER SOCK OR APPROVED EQUAL. INSTALL 20 TONS OF CLASS D REVETMENT STONE RIP-RAP (EACH LOCATION) AS GENERALLY SHOWN AND IN ACCORDANCE WITH THE 2022 SUDAS. REFER TO DETAIL 5/C3.1. PORTABLE TOILET DUMPSTER TURF REINFORCEMENT MAT FILTER SOCK PROPOSED GRADE LINES LIMITS OF DISTURBED AREA EXISTING GRADE LINES TEMPORARY & PERMANENT SEEDING SCALE: NTS 2 C3 RIP-RAP STAGES OF CONSTRUCTION: 1. CONTACT THE CITY OF WAUKEE PUBLIC WORKS 48 HRS PRIOR TO CONSTRUCTION. 2. CONTRACTOR TO PERFORM DETAILED SITE INSPECTION TO LOCATE ALL EXISTING UTILITIES AND VERIFY ANY POSSIBLE CONFLICTS WITH PROPOSED IMPROVEMENTS PRIOR TO BEGINNING ANY CONSTRUCTION. CONTACT OWNER WITH ANY CONFLICTS. MONTH 1 3. INSTALLATION OF CONSTRUCTION ENTRANCE. MONTH 1 4. INSTALLATION OF EROSION & SEDIMENT CONTROL FENCE. MONTH 1 5. DEMOLITION OF EXISTING SITE IMPROVEMENTS. MONTH 1 6. REMOVAL OF EXISTING PAVEMENT ON THE SITE. MONTH 1 7. INSTALLATION OF ALL STORM WATER DRAINAGE IMPROVEMENTS. MONTH 1 8. ROUGH GRADING. MONTH 1 & MONTH 2 9. CONSTRUCTION OF NEW SITE IMPROVEMENTS. MONTH 2 10. FINAL GRADING. MONTH 3 11. PLACEMENT OF FINAL LANDSCAPING ITEMS AND SOD. MONTH 3 12. CONTACT THE CITY OF WAUKEE PUBLIC WORKS FOR FINAL INSPECTION FOR CLOSE OUT. MONTH 3 13. REMOVAL OF EROSION & SEDIMENT CONTROL FENCE. MONTH 3 MAINTENANCE OF DETENTION FACILITIES IS THE RESPONSIBILITY OF THE PROPERTY OWNER POST CONSTRUCTION. SOD 36,000 SQ FT 1 CITY COMMENTS 06/27/2022 2 CITY COMMENTS 07/25/2022 3 CITY COMMENTS 08/09/2022 NOTE: ADS CHAMBERS ARE POST CONSTRUCTION FEATURES. 4 CITY COMMENTS 08/23/2022 6 CITY COMMENTS 09/15/2022 8 CITY COMMENTS 10/24/2022 8 Digitally signed by Jared Davis, PE DN: C=US, E=jmdavis@andersonengineeringinc.com, O="Anderson Engineering, Inc", OU=VP, CN="Jared Davis, PE" Date: 2022.10.27 14:23:24-05'00' DRAWING INFORMATION PROJECT NO: ISSUED FOR: CHECK BY: DRAWN BY: SHEET NUMBER ENGINEERS · SURVEYORS LABORATORIES · DRILLING 3213 S WEST BYPASS SPRINGFIELD, MO 65807 PHONE (417) 866-2741 SHEET TITLE DATEDESCRIPTIONNO. ISSUED FOR ISSUED BY: LICENSE NO: ISSUED DATE: GERBER COLLISION & GLASS WILLIAMS POINTE WAUKEE, IA CMH JMD JARED M. DAVIS PE No. P25497 A LICENSED MISSOURI ENGINEERING CORPORATION COA 00062 22SP10014 PERMIT 06/07/2022 EXP: 12/31/2022 C3.1 EROSION & SEDIMENT CONTROL DETAILS INSTALL 1-2" DIAMETER CLEAN ROCK WITH GEOTEXTILE FABRIC COVERING OPENINGS DURING CONSTRUCTION CENTERED ON ORIFICE OPENING. GEOTEXTILE FABRICREFER TO SHEET C2.1 FOR OUTLET INVERT. OUTLET PROTECTION SCALE: NOT TO SCALE 4 C3.1 STABILIZED CONSTRUCTION ENTRANCE SCALE: NOT TO SCALE 2 C3.1 CONCRETE WASHOUT SCALE: NOT TO SCALE 3 C3.1 FILTER SOCK SCALE: NOT TO SCALE 1 C3.1 RIP-RAP DETAIL SCALE: NOT TO SCALE 5 C3.1 1 CITY COMMENTS 06/27/2022 2 CITY COMMENTS 07/25/2022 4 CITY COMMENTS 08/23/2022 DIMENSIONS APPLY FOR ALL RIP-RAP PADS. 5 CITY COMMENTS 09/06/2022 5 Digitally signed by Jared Davis, PE DN: C=US, E=jmdavis@andersonengineeringinc.com, O="Anderson Engineering, Inc", OU=VP, CN="Jared Davis, PE" Date: 2022.09.06 16:43:16-05'00' 1048 1047 1046 1045 1045 1046 1047 1048 SE B R I C K D R I V E SE B R I C K D R I V E 10 5 5 1054 1054 1051 10 4 9 1 0 5 5 105 4 1054 1055 1055 10 5 5 10 5 5 1055 10 5 4 10 5 4 10 5 4 1055 1054 10521051 1057 1055 1055 1055 105 0 1049 105 0 1 0 5 2 1 0 5 1 1 0 5 3 1052 1053 1056 1053 1055 1055 10 4 6 10 4 5 10 4 4 10 4 3 10 4 2 10 4 1 10 4 0 1040104110421043104410451046 10 5 1 10 5 2 10 5 3 10 5 4 1051 10 5 4 10 5 1 10 4 9 10 5 3 10 4 6 10 4 7 1052 10 5 0 1050 10 5 0 10 5 0 1 0 5 0 SITE UTILITY PLAN SCALE: 1" = 30' 1 C4 DRAWING INFORMATION PROJECT NO: ISSUED FOR: CHECK BY: DRAWN BY: SHEET NUMBER ENGINEERS · SURVEYORS LABORATORIES · DRILLING 3213 S WEST BYPASS SPRINGFIELD, MO 65807 PHONE (417) 866-2741 SHEET TITLE DATEDESCRIPTIONNO. ISSUED FOR ISSUED BY: LICENSE NO: ISSUED DATE: GERBER COLLISION & GLASS WILLIAMS POINTE WAUKEE, IA CMH JMD JARED M. DAVIS PE No. P25497 A LICENSED MISSOURI ENGINEERING CORPORATION COA 00062 22SP10014 PERMIT 06/07/2022 EXP: 12/31/2022 C4 SITE UTILITY PLAN 1. WATER LINES SHALL HAVE A MIN. 10 FEET HORIZONTAL CLEARANCE AND 18 INCHES VERTICAL CLEARANCE (MEASURED FROM EDGE OF PIPE TO EDGE OF PIPE) FROM ALL SANITARY SEWER LINES. 2. WATER LINES SHALL HAVE A MINIMUM OF 66 INCHES OF COVER, UNLESS OTHERWISE NOTED, MEASURED FROM THE TOP OF FINISHED GROUND TO THE TOP OF PIPE. 3. THERE SHALL BE A MINIMUM OF 18 INCHES CLEARANCE MEASURED FROM THE BOTTOM OF ANY STORMWATER PIPE TO THE TOP OF WATER LINES AT ALL CROSSING. 4. AT WATER AND SANITARY SEWER CROSSINGS, THE FULL LENGTH OF WATER PIPE SHALL BE LOCATED SO BOTH JOINTS WILL BE AS FAR FROM SEWER AS POSSIBLE. SPECIAL STRUCTURAL SUPPORT FOR THE WATER AND SEWER PIPES MAY BE REQUIRED. 5. THE GENERAL CONTRACTOR SHALL TAKE ALL PRECAUTIONS NECESSARY TO AVOID PROPERTY DAMAGE TO ADJACENT PROPERTIES DURING THE CONSTRUCTION PHASES OF THIS PROJECT. 6. CONTRACTOR IS TO REMOVE AND DISPOSE OF ALL DEBRIS, RUBBISH AND OTHER MATERIALS RESULTING FROM DEMOLITION OPERATIONS. DISPOSAL WILL BE IN ACCORDANCE WITH ALL LOCAL, STATE AND /OR FEDERAL REGULATIONS GOVERNING SUCH OPERATIONS. 7. NOTICE TO CONTRACTOR:PRIOR TO INSTALLATION OF WATER LINE, THE CONTRACTOR SHALL EXCAVATE, VERIFY, AND CALCULATE ALL CROSSINGS AND INFORM THE OWNER AND ANDERSON ENGINEERING OF ANY CONFLICTS PRIOR TO CONSTRUCTION. 8. ALL SANITARY SEWER AND WATER LINE CONSTRUCTION MUST COMPLY WITH THE 2020 WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND 2022 SUDAS. CONTRACTOR TO PERFORM DETAILED SITE INSPECTION TO LOCATE ALL EXISTING UTILITES AND VERIFY ANY POSSIBLE CONFLICTS WITH PROPOSED IMPROVEMENTS PRIOR TO BEGINNING ANY CONSTRUCTION. CONTACT ENGINEER WITH ANY CONFLICTS. UTILITY GENERAL NOTES IT IS THE CONTRACTOR'S RESPONSIBILITY TO LOCATE AND MOVE ANY AFFECTED UTILITIES. THE ENGINEER DOES NOT GUARANTEE THAT ALL UTILITIES ARE SHOWN ON THESE PLANS. IT SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT THE CITY OF CONWAY, MO OR OTHER SUPPLIERS OF UTILITIES AND ARRANGE FOR ANY NECESSARY MODIFICATIONS REQUIRED TO FACILITATE CONSTRUCTION ACTIVITIES. INFORMATION ON THIS DRAWING CONCERNING TYPE AND LOCATION OF UNDERGROUND AND OTHER UTILITIES IS NOT GUARANTEED TO BE ACCURATE OR ALL INCLUSIVE. THE CONTRACTOR IS RESPONSIBLE FOR MAKING HIS OWN DETERMINATION AS TO THE TYPE AND LOCATION OF UNDERGROUND AND OTHER UTILITIES AS MAY BE NECESSARY TO AVOID DAMAGE THERETO. BEFORE STARTING ANY BUILDING PAD GRADING AND PLUMBING WORK THE CONTRACTOR SHALL FIELD VERIFY LOCATION, MATERIAL, CONDITION, ACCESSIBILITY (INCLUDING STATE HIGHWAY OR OTHER RIGHTS-OF-WAY) AND WORKABLE FLOW LINE ELEVATION OF THE EXISTING SANITARY SEWER SERVICE LINE OR MAIN. IF A WORKABLE FLOW LINE HAS NOT BEEN ESTABLISHED AT THE TIME OF FINAL SANITARY SEWER SERVICE CONNECTION. THEN THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXPENSES ASSOCIATED WITH THE INSTALLATION OF A NEW GRINDER PUMP SYSTEM TO MEET OWNER AND LOCAL REQUIREMENTS. CONTRACTOR CAUTION!! CAUTION (SYMBOLS APPLY ONLY WHEN USED ON DRAWINGS) U/G ELECTRIC WATER SERVICE U/G PHONE U/G PHONE (BY PHONE CO.) SANITARY SEWER SERVICE OVERHEAD ELECTRIC OVERHEAD PHONE SAW CUT BORE FIBER OPTIC CABLE P.O.C. = POINT OF CONNECTION BETWEEN SITE PIPING (SPEC 33 00 00) AND BUILDING PIPING (SPEC 22 00 00, 21 13 13). AS NECESSARY - SPEC 22 00 00 DENOTES LANDSCAPE IRRIGATION. FIRE SERVICE GAS SERVICE 1. IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. 2. THE DUTY OF THE ENGINEER OR OWNER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES IN, ON, OR NEAR THE CONSTRUCTION SITE. SAFETY NOTICE TO CONTRACTORS SANITARY SEWER CLEANOUT SCALE: NOT TO SCALE 4 PIPE INSTALLATION DETAIL SCALE: NOT TO SCALE 2 ELECTRICAL CONDUITS SCALE: NOT TO SCALE 3 UNDERGROUND FOR COMMERCIAL BUILDINGS SCALE: NOT TO SCALE 5 REFER TO MEP PLAN FOR ELECTRICAL AND DATA DESIGN. CITY OF WAUKEE WATER SERVICE SCALE: NOT TO SCALE 6 CITY OF WAUKEE HYDRANT 1 CITY COMMENTS 06/27/2022 2 CITY COMMENTS 07/25/2022 3 CITY COMMENTS 08/09/2022 4 CITY COMMENTS 08/23/2022 5 CITY COMMENTS 09/06/2022 6 CITY COMMENTS 09/15/2022 7 CITY COMMENTS 10/03/2022 8 CITY COMMENTS 10/24/2022 8 Digitally signed by Jared Davis, PE DN: C=US, E=jmdavis@andersonengineeringinc.com, O="Anderson Engineering, Inc", OU=VP, CN="Jared Davis, PE" Date: 2022.10.28 08:09:39-05'00' 1048 1047 1046 45 1045 1046 DR I V E SE B R I C K D R I V E 10 5 5 1054 1054 1051 10 4 9 1 0 5 5 105 4 1054 1055 1055 10 5 5 10 5 5 1055 10 5 4 10 5 4 10 5 4 1055 1054 10521051 1057 1055 1055 1055 105 0 1049 105 0 1 0 5 2 1 0 5 1 1 0 5 3 1052 1053 1056 1053 1055 1055 10 4 6 10 4 5 10 4 4 10 4 3 10 4 2 10 4 1 10 4 0 1040104110421043104410451046 10 5 1 10 5 2 10 5 3 10 5 4 1051 10 5 4 10 5 1 10 4 9 10 5 3 10 4 6 10 4 7 1052 10 5 0 1050 10 5 0 10 5 0 1 0 5 0 LANDSCAPE PLAN SCALE: 1" = 30' 1 C5 DRAWING INFORMATION PROJECT NO: ISSUED FOR: CHECK BY: DRAWN BY: SHEET NUMBER ENGINEERS · SURVEYORS LABORATORIES · DRILLING 3213 S WEST BYPASS SPRINGFIELD, MO 65807 PHONE (417) 866-2741 SHEET TITLE DATEDESCRIPTIONNO. ISSUED FOR ISSUED BY: LICENSE NO: ISSUED DATE: GERBER COLLISION & GLASS WILLIAMS POINTE WAUKEE, IA CMH JMD JARED M. DAVIS PE No. P25497 A LICENSED MISSOURI ENGINEERING CORPORATION COA 00062 22SP10014 PERMIT 06/07/2022 EXP: 12/31/2022 C5 LANDSCAPE PLAN OPEN SPACE: PROVIDE A MINIMUM OF 20% OPEN SPACE. TOTAL SITE = 2.18 ACRES = 94,755 SF PROPOSED IMPERVIOUS = 56,655 SF PROPOSED PERVIOUS = 38,100 SF PROVIDED OPEN SPACE = 41% PROVIDED > 20% REQUIRED MINIMUM LANDSCAPING REQUIREMENTS (EXCLUDING BUFFER LANDSCAPING) PROVIDE 1 TREE AND 1 SHRUB PER 1,000 SF OF REQUIRED OPEN SPACE. 50% OFF ALL REQUIRED TREES SHALL BE OVERSTORY SHADE TREES AND 25% OF ALL REQUIRED TREES SHALL BE EVERGREEN TREES. REQUIRED OPEN SPACE = 17,124 REQUIRED & PROVIDED TREES = 18 TREES REQUIRED & PROVIDED OVERSTORY TREES = 9 TREES REQUIRED & PROVIDED EVERGREEN TREES = 5 TREES REQUIRED & PROVIDED ORNAMENTAL TREES = 4 TREES REQUIRED & PROVIDED SHRUBS = 18 SHURBS NORTH BUFFER LANDSCAPING PROVIDE A 30' BUFFER YARD ALONG THE NORTH PROPERTY LINE 2 OVERSTORY, 3 EVERGREEN & 2 ORNAMENTAL TREES REQUIRED PER 50 LINEAR FEET OF BUFFER. BUFFER LENGTH = 471' REQUIRED & PROVIDED TREES = 20 OVERSTORY, 30 EVERGREEN & 20 ORNAMENTAL TREES EAST BUFFER LANDSCAPING PROVIDE A 30' BUFFER YARD ALONG THE EAST PROPERTY LINE 2 OVERSTORY, 3 EVERGREEN & 2 ORNAMENTAL TREES REQUIRED PER 50 LINEAR FEET OF BUFFER. BUFFER LENGTH = 215' REQUIRED & PROVIDED TREES = 10 OVERSTORY, 15 EVERGREEN & 10 ORNAMENTAL TREES INTERIOR PARKING LANDSCAPING PROVIDE AT LEAST ONE ORNAMENTAL OR ONE DECIDUOUS OVERSTORY TREE WITH A MINIMUM OF 50 PERCENT OF THE LANDSCAPED ISLAND PROVIDED WITH A DECIDUOUS OVERSTORY TREE. REQUIRED & PROVIDED DECIDUOUS OVERSTORY TREE = 1 TREE NOTE: ANY CHANGES TO THE LANDSCAPING PLAN NEEDS TO BE APPROVED IN WRITING BY THE CITY OF WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT. REQUIRED LANDSCAPING: LANDSCAPE LEGEND DECIDUOUS OVERSTORY TREE MIN. HEIGHT REQUIRED = 8', OR APPROVED ALTERNATE: x RED MAPLE (Acer Rubrum) DECIDUOUS ORNAMENTAL TREE HEIGHT REQUIRED = 6', OR APPROVED ALTERNATE: x SWEETBAY MAGNOLIA (Magnolia virginiana) EVERGREEN OVERSTORY TREE HEIGHT REQUIRED = 6', OR APPROVED ALTERNATE: x AUSTRIAN PINE (Pinus Nigra) SHRUB, OR APPROVED ALTERNATE: x ELDERBERRY (ambucus canadensis) 1 CITY COMMENTS 06/27/2022 2 CITY COMMENTS 07/25/2022 3 CITY COMMENTS 08/09/2022 4 CITY COMMENTS 08/23/2022 8 CITY COMMENTS 10/24/2022 8 8 Digitally signed by Jared Davis, PE DN: C=US, E=jmdavis@andersonengineeringinc.com, O="Anderson Engineering, Inc", OU=VP, CN="Jared Davis, PE" Date: 2022.10.27 14:25:15-05'00' 1048 1047 1046 45 1045 1046 IV E SE B R I C K D R I V E 10 5 5 1054 1054 1051 10 4 9 1 0 5 5 105 4 1054 1055 1055 10 5 5 10 5 5 1055 10 5 4 10 5 4 10 5 4 1055 1054 10521051 1057 1055 1055 1055 105 0 1049 105 0 1 0 5 2 1 0 5 1 1 0 5 3 1052 1053 1056 1053 1055 1055 10 4 6 10 4 5 10 4 4 10 4 3 10 4 2 10 4 1 10 4 0 1040104110421043104410451046 10 5 1 10 5 2 10 5 3 10 5 4 1051 10 5 4 10 5 1 10 4 9 10 5 3 10 4 6 10 4 7 5051051050505 5005050 1052 10 5 0 1050 10 5 0 10 5 0 1 0 5 0 STORMWATER MAINTENANCE PLAN SCALE: 1" = 30' 1 C5 DRAWING INFORMATION PROJECT NO: ISSUED FOR: CHECK BY: DRAWN BY: SHEET NUMBER ENGINEERS · SURVEYORS LABORATORIES · DRILLING 3213 S WEST BYPASS SPRINGFIELD, MO 65807 PHONE (417) 866-2741 SHEET TITLE DATEDESCRIPTIONNO. ISSUED FOR ISSUED BY: LICENSE NO: ISSUED DATE: GERBER COLLISION & GLASS WILLIAMS POINTE WAUKEE, IA CMH JMD JARED M. DAVIS PE No. P25497 A LICENSED MISSOURI ENGINEERING CORPORATION COA 00062 22SP10014 PERMIT 06/07/2022 EXP: 12/31/2022 C6 STORMWATER MAINTENANCE PLAN RESPONSIBLE MAINTENANCE PERSONNEL PROPERTY OWNER. SCHEDULE OF DETENTION SYSTEM INSPECTIONS THE MAINTENANCE PERSONNEL SHALL INSPECT POLLUTION CONTROL MEASURES AT LEAST ONCE EVERY 6 MONTHS AND WITHIN 24 HOURS AFTER A STORM EVENT OF 1 INCH OR GREATER. DAMAGED MEASURES THAT PROVE TO BE INEFFECTIVE SHALL BE REPLACED WITH MORE EFFECTIVE MEASURES OR ADDITIONAL MEASURES WITHIN SEVEN DAYS. REPEATED FAILURE OF A CONTROL MEASURE REQUIRES INSTALLATION OF A MORE SUITABLE DEVICE TO PREVENT DISCHARGE OF POLLUTANTS FROM THE CONSTRUCTION SITE. THE OWNER WILL KEEP A RECORD OF ALL INSPECTIONS. DETENTION SYSTEM INSPECTION PROCEDURE: 1. MAKE A COPY OF THE DETENTION INSPECTION FORM FROM THE MAINTENANCE MANUAL. 2. VISUALLY INSPECT EACH INLET AND NOTE ON THE INSPECTION FORM THE AMOUNT OF SEDIMENT ACCUMULATED IN THE INLET. 3. THE MAINTENANCE PERSON MEASURE THE SEDIMENT DEPTHS AT THE BOTTOM OF THE PIPES UNDER EACH INLET (JUST STICK A ROD THROUGH THE INLET COVER, DON'T EVEN BOTHER TO REMOVE), AND THEN WHEN THE ACCUMULATED SEDIMENT GETS DEEPER THAN A COUPLE OF INCHES, THE ENTIRE SYSTEM NEEDS TO BE CLEANED OUT. A PROFESSIONAL COMPANY COULD BE HIRED TO DO THE CLEANED OUT. THE SEDIMENT AND ANY WASH OR CLEANOUT WATER SHOULD BE HAULED OFF-SITE FOR PROPER DISPOSAL, NOT DISCHARGED TO THE OUTFALL. 4. NOTE ON THE DETENTION INSPECTION FORM THAT THE INLET HAS BEEN CLEANED. 5. CONTACT THE LOCAL LANDFILL OR GARBAGE COLLECTION COMPANY TO COORDINATE A PICK UP AND DISPOSAL OF THE SEDIMENT. 6. SPECIFICALLY INSPECTING THE OUTFALL PIPE AREA FOR EROSION, DEBRIS OR DAMAGE. 7. WALK THE SITE AND NOTE ANY AREAS OF SOIL EROSION OR POLLUTION DISCHARGE FROM THE SITE. MAKE NOTE OF THESE OCCURRENCES ON THE DETENTION INSPECTION FORM AND CONTACT THE OWNER TO SCHEDULE A REPAIR OF THESE AREAS. 8. SIGN & DATE THE REPORT, FAX A COPY TO THE OWNER, AND FILE THE ORIGINAL IN THE ON-SITE INSPECTION MANUAL. DETENTION SYSTEM INSPECTION FORM STEP 1. INSPECT SYSTEM FOR SEDIMENT & DEBRIS: CHECK THE BOX FOR EACH ITEM INSPECTED: INLET #1: □INLET #2: □INLET #3: □ DETENTION OUTLET: □ STEP 2. NOTE ANY SEDIMENT OR DEBRIS WITH INLET # AND DEPTH: _______________________________________________________________ STEP 3. VERIFY THAT EACH INLET HAS BEEN CLEANED: CHECK THE BOX FOR EACH STRUCTURE TO CONFIRM IS IT CLEAN OF SEDIMENT & DEBRIS: INLET #1: □ INLET #2: □ INLET #3: □ DETENTION OUTLET STRUCTURE: □ PIPE OUTLET: □ STEP 4. VISUAL INSPECTION & RECORD OF ANY SITE EROSION: _________________________________________________________ ________________________________________________________ STEP 5. SIGN, DATE, FAX COPY TO OWNER & FILE: _______________________ ____________________ _____________ PRINTED NAME OF INSPECTOR SIGNATURE OF INSPECTOR DATE DETENTION SYSTEM MAINTENANCE PROCEDURES DETENTION CONTROL STRUCTURE MAINTENANCE BLOCKAGES ALL TRASH, SEDIMENT, AND DEBRIS BLOCKING THE ENTRY OR PASSAGE OF STORM FLOWS INTO OR THROUGH THE CONTROL STRUCTURE SHOULD BE REMOVED. STRUCTURAL INTEGRITY DEPENDING ON THE SEVERITY OF THE DETERIORATION, THE CONTROL STRUCTURE MAY NEED TO BE REPLACED. IF THE OVERALL INTEGRITY OF THE STRUCTURE IS REASONABLY SOUND, THE FOLLOWING REPAIRS SHOULD BE CONSIDERED: CRACKS SHOULD BE SEALED WITH AN EPOXY LOW-SHRINK GROUT. SPALLED AREAS SHOULD BE REPAIRED WITH A TWO-PART CEMENT-BONDING AGENT AND THEN PAINTED. RUSTED AREAS, IF REPARABLE, SHOULD BE SCRAPED, CLEANED, PRIMED, PAINTED WITH TWO COATS OF RUST-RESISTANT PAINT, AND, IF APPROPRIATE, COATED WITH A BITUMINOUS SEALANT. INSUFFICIENT DEBRIS MANAGEMENT IF THE STRUCTURE CLOGS ROUTINELY TO A POINT WHERE STORMWATER CONTINUES TO STAY IN THE SYSTEM FOR LONGER PERIODS THAN THREE DAYS, IT MAY MEAN THAT THE LOW-FLOW ORIFICE AT THE BOTTOM OF THE CONTROL STRUCTURE MAY REQUIRE A TRASH RACK IN ADDITION TO THE PIT GRATING TO MITIGATE THE CLOGGING OF THE DEVICE. CHECK FOR SETTLING; STRUCTURAL CRACKS; BURROWS, HOLES OR VOIDS AROUND STRUCTURE AND BARREL; DAMAGE TO ORIFICE OR WEIR COMPONENTS; SEDIMENT ACCUMULATION; BLOCKAGE OF OUTLET STRUCTURE ORIFICES AND WEIRS; LOOSE OR MISSING GRATES, MANHOLE LIDS AND TRASH RACKS; EROSION AT POND OUTFALL OR EVIDENCE OF ANY VOIDS IN AND AROUND OUTLET HEADWALL/BARREL. MAKE ANY NECESSARY REPAIRS AND REMOVE ALL BLOCKAGES, INCLUDING GROWTH OF WOODY VEGETATION. DETENTION POND MAINTENANCE TRASH, SEDIMENT, AND DEBRIS ALL TRASH, SEDIMENT, AND DEBRIS SHOULD BE REMOVED FROM THE DETENTION/RETENTION POND AT LEAST TWICE A YEAR OR MORE FREQUENTLY IF THE AMOUNT OF ACCUMULATED MATERIAL WARRANTS SUCH A PRACTICE. LANDSCAPING PRACTICES GENERALLY, NO MOWING OR LIMITED MAINTENANCE OF POND BOTTOMS ARE REQUIRED. REMOVE LOOSE VEGETATION, AS NECESSARY. THE POND SHALL BE ACCESSED THROUGH THE 3:1 SLOPE AS SHOWN ON PLANS. THE RETAINING WALL SHALL BE INSPECTED AT LEAST TWICE A YEAR AND ANY CRACKS OR LEANING SHALL BE NOTED AND FORWARDED TO O'REILLY AUTOMOTIVE CORPORATE OFFICE. CRUSHED, COLLAPSED, OR RUSTED-OUT SECTIONS OF PIPE IN MOST INSTANCES, A PIPE IN THIS CONDITION SHOULD BE REMOVED AND REPLACED UNDER THE SUPERVISION OF A REGISTERED PROFESSIONAL ENGINEER. DAM, EMBANKMENTS & EMERGENCY SPILLWAY CHECK FOR ANIMAL BURROWS; EROSION, RILLS OR GULLIES; SEEPAGE; EVIDENCE OF SETTLING (ESPECIALLY IN VICINITY OF OUTLET BARREL); NON-PERMITTED ENCROACHMENTS OR WOODY VEGETATION ALONG DAM OR DAM EMBANKMENT. MAKE ANY NECESSARY REPAIRS, INCLUDING APPROPRIATE MEASURES TO PERMANENTLY STABILIZE SLOPES, EMBANKMENT & SPILLWAY. POND BOTTOM IF SEDIMENT ACCUMULATION COMPROMISES POND STORAGE CAPABILITY, THEN SEDIMENT SHALL BE REMOVED AND PROPERLY DISPOSED OF. WETLAND TYPE PONDS MAY REMAIN WET OR “SWAMPY” FOR PROLONG PERIODS OF TIME, DEPENDING ON TOPOGRAPHIC LAYOUT OF POND AND GROUND WATER SOURCES. OUTFALL AREA MAINTENANCE BLOCKAGES A BLOCKED OUTFALL CHANNEL SHOULD BE OPENED UP AS SOON AS PRACTICABLE, ESPECIALLY IF THE CHANNEL IS BACKING A SIGNIFICANT AMOUNT OF WATER UP INSIDE THE CONTROL STRUCTURE OR DETENTION CHAMBERS/PIPES. TYPICALLY, OUTFALL CHANNELS SHOULD BE CLEARED OF TREES FOR A DISTANCE, DOWNSTREAM FROM THE OUTFALL STRUCTURE, OF AT LEAST 5 TIMES THE DIAMETER OF THE PRINCIPAL SPILLWAY PIPE. FOR EXAMPLE, THE CLEARING AREA FOR A 36” (THREE-FOOT) DIAMETER OUTLET PIPE WOULD BE 15-FEET LONG. NOTE: ESTABLISHED VEGETATION AND TREES ON THE STREAM BANKS SHOULD BE LEFT IN PLACE. THE “CLEARING” SHOULD BE LIMITED TO THE REMOVAL OF DEAD AND FALLEN TREES AND ANYTHING IN THE FLOW-LINE OF THE CHANNEL THAT SIGNIFICANTLY PREVENTS WATER FROM EXITING THE POND FACILITY. EROSION ERODED OUTFALL CHANNELS SHOULD BE REPAIRED AS SOON AS PRACTICABLE WITH ADDITIONAL RIPRAP ARMORING OR OTHER PERMANENT LINING MATERIAL. INLET MAINTENANCE INLETS INLETS TO THE DETENTION SYSTEM SHOULD BE KEPT OPEN AND IN GOOD WORKING CONDITION. ALL ERODED AREAS SHOULD BE REPAIRED. GENERAL MAINTENANCE: INSPECT INLET PIPES, OUTFLOW BARREL AND OUTLET STRUCTURE WEIRS AND ORIFICES MONTHLY AND AFTER EACH SIGNIFICANT RAIN EVENT (0.5” OR GREATER). REMOVE FOREIGN DEBRIS, TRASH, LITTER, VEGETATION OR BLOCKAGES TO ENSURE FLOW OF STORMWATER IS NOT IMPEDED AND REPAIR OR REPLACE ROCK RIP-RAP AT OUTFALLS, AS NEEDED. DO NOT USE PESTICIDES, HERBICIDES, OR FERTILIZERS IN AND AROUND POND, OR NEAR CONTRIBUTING STORMWATER INLETS (THIS CAN COMPROMISE THE WATER QUALITY EFFECTIVENESS OF POND AND POLLUTE STREAMS OR WATER BODIES). INSPECTION LOG - OWNER SHALL KEEP AN INSPECTION RECORD FOR ALL INSPECTIONS PERFORMED AND MAINTENANCE MEASURES TAKEN. IF MAJOR DAM OR OUTLET STRUCTURE REPAIRS ARE NEEDED, PLEASE CONTACT THE CITY OF WAUKEE PUBLIC WORKS DEPARTMENT AT 515-978-7920. 1055 EXISTING GRADE LINES PROPOSED NEW GRADE LINES 1 CITY COMMENTS 06/27/2022 2 CITY COMMENTS 07/25/2022 3 CITY COMMENTS 08/09/2022 3 4 CITY COMMENTS 08/23/2022 8 CITY COMMENTS 10/24/2022 8 8 Digitally signed by Jared Davis, PE DN: C=US, E=jmdavis@andersonengineeringinc.com, O="Anderson Engineering, Inc", OU=VP, CN="Jared Davis, PE" Date: 2022.10.27 14:25:25-05'00' DRAWING INFORMATION PROJECT NO: ISSUED FOR: CHECK BY: DRAWN BY: SHEET NUMBER ENGINEERS · SURVEYORS LABORATORIES · DRILLING 3213 S WEST BYPASS SPRINGFIELD, MO 65807 PHONE (417) 866-2741 SHEET TITLE DATEDESCRIPTIONNO. ISSUED FOR ISSUED BY: LICENSE NO: ISSUED DATE: GERBER COLLISION & GLASS WILLIAMS POINTE WAUKEE, IA CMH JMD JARED M. DAVIS PE No. P25497 A LICENSED MISSOURI ENGINEERING CORPORATION COA 00062 22SP10014 PERMIT 06/07/2022 EXP: 12/31/2022 C6.1 ADS MAINTENANCE PLAN 08/23/2022 Digitally signed by Jared Davis, PE DN: C=US, E=jmdavis@andersonengineeringinc.com, O="Anderson Engineering, Inc", OU=VP, CN="Jared Davis, PE" Date: 2022.08.23 17:08:05-05'00' DRAWING INFORMATION PROJECT NO: ISSUED FOR: CHECK BY: DRAWN BY: SHEET NUMBER ENGINEERS · SURVEYORS LABORATORIES · DRILLING 3213 S WEST BYPASS SPRINGFIELD, MO 65807 PHONE (417) 866-2741 SHEET TITLE DATEDESCRIPTIONNO. ISSUED FOR ISSUED BY: LICENSE NO: ISSUED DATE: GERBER COLLISION & GLASS WILLIAMS POINTE WAUKEE, IA CMH JMD JARED M. DAVIS PE No. P25497 A LICENSED MISSOURI ENGINEERING CORPORATION COA 00062 22SP10014 PERMIT 06/07/2022 EXP: 12/31/2022 C7 ADS BED 1 STORMTECH DETAILS 1 08/23/2022 6 CITY COMMENTS 09/15/2022 6 6 Digitally signed by Jared Davis, PE DN: C=US, E=jmdavis@andersonengineeringinc.com, O="Anderson Engineering, Inc", OU=VP, CN="Jared Davis, PE" Date: 2022.09.16 07:42:29-05'00' DRAWING INFORMATION PROJECT NO: ISSUED FOR: CHECK BY: DRAWN BY: SHEET NUMBER ENGINEERS · SURVEYORS LABORATORIES · DRILLING 3213 S WEST BYPASS SPRINGFIELD, MO 65807 PHONE (417) 866-2741 SHEET TITLE DATEDESCRIPTIONNO. ISSUED FOR ISSUED BY: LICENSE NO: ISSUED DATE: GERBER COLLISION & GLASS WILLIAMS POINTE WAUKEE, IA CMH JMD JARED M. DAVIS PE No. P25497 A LICENSED MISSOURI ENGINEERING CORPORATION COA 00062 22SP10014 PERMIT 06/07/2022 EXP: 12/31/2022 C7.1 ADS BED 1 STORMTECH DETAILS 2 08/23/2022 6 CITY COMMENTS 09/15/2022 6 6 Digitally signed by Jared Davis, PE DN: C=US, E=jmdavis@andersonengineeringinc.com, O="Anderson Engineering, Inc", OU=VP, CN="Jared Davis, PE" Date: 2022.09.16 07:42:16-05'00' DRAWING INFORMATION PROJECT NO: ISSUED FOR: CHECK BY: DRAWN BY: SHEET NUMBER ENGINEERS · SURVEYORS LABORATORIES · DRILLING 3213 S WEST BYPASS SPRINGFIELD, MO 65807 PHONE (417) 866-2741 SHEET TITLE DATEDESCRIPTIONNO. ISSUED FOR ISSUED BY: LICENSE NO: ISSUED DATE: GERBER COLLISION & GLASS WILLIAMS POINTE WAUKEE, IA CMH JMD JARED M. DAVIS PE No. P25497 A LICENSED MISSOURI ENGINEERING CORPORATION COA 00062 22SP10014 PERMIT 06/07/2022 EXP: 12/31/2022 C8 ADS BED 2 STORMTECH DETAILS 1 08/23/2022 6 CITY COMMENTS 09/15/2022 6 6 Digitally signed by Jared Davis, PE DN: C=US, E=jmdavis@andersonengineeringinc.com, O="Anderson Engineering, Inc", OU=VP, CN="Jared Davis, PE" Date: 2022.09.16 07:42:59-05'00' DRAWING INFORMATION PROJECT NO: ISSUED FOR: CHECK BY: DRAWN BY: SHEET NUMBER ENGINEERS · SURVEYORS LABORATORIES · DRILLING 3213 S WEST BYPASS SPRINGFIELD, MO 65807 PHONE (417) 866-2741 SHEET TITLE DATEDESCRIPTIONNO. ISSUED FOR ISSUED BY: LICENSE NO: ISSUED DATE: GERBER COLLISION & GLASS WILLIAMS POINTE WAUKEE, IA CMH JMD JARED M. DAVIS PE No. P25497 A LICENSED MISSOURI ENGINEERING CORPORATION COA 00062 22SP10014 PERMIT 06/07/2022 EXP: 12/31/2022 C8.1 ADS BED 2 STORMTECH DETAILS 2 08/23/2022 6 CITY COMMENTS 09/15/2022 6 6 Digitally signed by Jared Davis, PE DN: C=US, E=jmdavis@andersonengineeringinc.com, O="Anderson Engineering, Inc", OU=VP, CN="Jared Davis, PE" Date: 2022.09.16 07:42:42-05'00' BUILDING MANHOLE: 1048.92 18" RCP FL OUT SW: 1045.27 18" RCP FL IN E: 1045.29 MANHOLE: 1050.54 18" RCP FL OUT W: 1046.95 18" RCP FL IN SE: 1046.98 MANHOLE: 1048.96 24" RCP FL OUT W: 1043.67 24" RCP FL IN E: 1043.75 GUTTER: 1048.94 BOTTOM WELL: 1045.79 MANHOLE: 1051.29 15" RCP FL OUT SW: 1047.79 GUTTER: 1050.90 15" RCP FL IN NE: 1047.20MANHOLE: 1051.41 18" RCP FL OUT NW: 1047.16 GUTTER: 1048.92 24" RCP FL OUT NW: 1044.33 18" RCP FL IN NE: 1044.51 12" FES 1GN-01 COVER SHEET NORTH N: \ P r o j e c t s \ W A K 2 0 2 1 8 0 3 8 \ D w g s \ P l a n s \ S a n i t a r y C o n s t r u c t i o n D r a w i n g s \ C o v e r a n d G e n e r a l N o t e s . d w g 10 / 2 6 / 2 0 2 2 9 : 0 8 A M ENGINEER/SURVEYOR MCCLURE ENGINEERING 1360 NW 121ST STREET CLIVE, IOWA 50325 (515) 964-1229 TSMITH@MCCLUREVISION.COM ATTN: TRENT SMITH OWNER/APPLICANT DSDH. WAUKEE, LLC 9251 WILLOW LANE FREMONT, WI 54940 DAVID HERBECK 920-428-9028 DAVE@HERBECKDEVELOPMENT.COM PROJECT LOCATION VICINITY MAP AL I C E S R D SE UNIVERSITY AVE I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF IOWA. TRENT LUNDY SMITH, PE NO. 26452 DATE: MY LICENSE RENEWAL DATE IS DECEMBER 31, 2022 PAGES OR SHEETS COVERED BY THIS SEAL: 1 - 3 SE B R I C K D R 75'150'0 GRAPHIC SCALE 300' DRAWING NO. CHECKED BY ENGINEER SHEET NO. FIELD BOOK NO. DRAWN BY REVISIONS NOTICE: McClure Engineering Company waives any and all responsibility and liability for problems which arise from failure to follow these Plans, Specifications, and the engineering intent they convey, or for problems which arise from failure to obtain and/or follow the engineers guidance with respect to any errors, omissions, inconsistencies, ambiguities, or conflicts which are alleged. COPYRIGHT: Copyright and property rights in these documents are expressly reserved by McClure Engineering Company. No reproductions, changes, or copies in any manner shall be made without obtaining prior written consent from McClure Engineering Company. 1360 NW 121ST. Street Clive, Iowa 50325 515-964-1229 fax 515-964-2370 making lives better WILLIAMS POINTE COMMERCIAL PLAT 1 CONSTRUCTION DRAWINGS WAUKEE, IOWA 20218038-000 MAY 2022 T SMITH T SMITH -- . . . . . WILLIAMS POINTE COMMERCIAL PLAT 1 CONSTRUCTION DRAWINGS WAUKEE, IA 06 AL I C E S R D SE B R I C K D R LOT 1 2.18 AC OUTLOT X 6.85 AC Sheet List Table Sheet Number Sheet Title 1 COVER SHEET 2 GENERAL NOTES 3 EXISTING CONDITIONS 4 GRADING AND EROSION CONTROL PLAN 5 SANITARY SEWER PLAN 6 STORM SEWER PLAN SUBMITTAL DATE DESCRIPTION 1 5/10/2022 CITY SUBMITTAL #1 2 9/29/2022 CITY SUBMITTAL #2 3 10/17/2022 CITY SUBMITTAL #3 4 10/26/2022 CITY SUBMITTAL #4 ALL CONSTRUCTION SHALL BE COMPLETED IN ACCORDANCE WITH THE 2022 IOWA STATEWIDE URBAN DESIGN STANDARD AND SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND THE 2020 WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS 2GN-02 GENERAL NOTES N: \ P r o j e c t s \ W A K 2 0 2 1 8 0 3 8 \ D w g s \ P l a n s \ S a n i t a r y C o n s t r u c t i o n D r a w i n g s \ C o v e r a n d G e n e r a l N o t e s . d w g 10 / 2 6 / 2 0 2 2 9 : 0 8 A M 1. CONTRACTOR TO PROTECT EXISTING PAVEMENT UNLESS DESIGNATED FOR REMOVAL. DAMAGED PAVEMENT SHALL BE REMOVED AND REPLACED AT THE CONTRACTOR'S EXPENSE. 2. CONTRACTOR TO CONFINE OPERATIONS TO PERMANENT AND TEMPORARY EASEMENTS AND DEVELOPER OWNED PROPERTY. 3. ALL TREES AND SHRUBS SHALL BE PROTECTED UNLESS DESIGNATED FOR REMOVAL IN THE PLANS. 4. CONTRACTOR SHALL SUBMIT ALL SUBGRADE AND PAVING MATERIAL TEST RESULTS TO THE PROJECT ENGINEER. 5. THE CONTRACTOR IS RESPONSIBLE FOR KEEPING AND MAINTAINING A SET OF RECORD DRAWINGS. RECORD DRAWINGS SHALL SHOW ALL CHANGES TO PLANS, AND REPRESENT THE AS-BUILT CONDITION. SUBMIT RECORD DRAWINGS TO ENGINEER PRIOR TO FINAL PAYMENT. 6. THE ENGINEER SHALL PROVIDE ALL CONSTRUCTION STAKING FOR PROJECT AND SHALL BE DISCUSSED IN DETAIL AT THE PRE-CONSTRUCTION MEETING. 7. THE PLANS SHOW UTILITIES LOCATED WITHIN THE LIMITS OF THE WORK UNDER THIS CONTRACT. THE COMPLETENESS OR ACCURACY OF THE INFORMATION SHOWN ON THE PLANS IS IN NO WAY IMPLIED OR GUARANTEED. THE CONTRACTOR SHALL OBTAIN THE LOCATION OF THE UTILITIES AND SERVICES FROM THE VARIOUS PUBLIC UTILITY COMPANIES BEFORE BEGINNING ANY EXCAVATION AND WILL BE HELD RESPONSIBLE FOR ANY DAMAGE TO SAID UTILITIES AND SERVICES RESULTING FROM HIS OPERATIONS. ADDITIONAL COMPENSATION WILL NOT BE ALLOWED FOR THIS WORK AND SHALL BE CONSIDERED INCIDENTAL TO OTHER AREAS OF WORK. 8. ALL STANDARD DETAILS SHALL BE CONSIDERED APPLICABLE TO CONSTRUCTION WORK ON THIS PROJECT. THE LIST OF STANDARD DETAILS SHOWN ON THIS SHEET ARE BROUGHT TO THE CONTRACTOR'S ATTENTION. THIS TABULATION SHALL NOT BE CONSIDERED A COMPLETE LIST OF ALL APPLICABLE STANDARD DETAILS. 9. CONTRACTOR IS RESPONSIBLE FOR ENSURING ALL SIDEWALKS, RAMPS, AND HANDICAP ACCESSIBLE SPACES TO SUDAS, ADA, AND PROWAG SPECIFICATIONS. 10. CONTRACTOR TO DETERMINE ALL FIELD TILE LOCATIONS AND ELEVATIONS ACROSS ALL LOTS TO THE PLAT BOUNDARY AND PROVIDE INFORMATION TO THE ENGINEER. A PLAN TO ADDRESS THE TILE LOCATIONS AND CONNECTIONS IS TO BE PROVIDED TO THE CITY FOR APPROVAL. 11. STORM SEWER WILL NEED TO BE TELEVISED ONCE COMPLETED. 12. SANITARY SEWER WILL NEED TO BE TELEVISED ONCE COMPLETED. PER SUDAS & WAUKEE SUPPLEMENTAL SPECIFICATIONS. 13. ALL SLURRY PRODUCED BY WET SAW CUTTING SHALL BE CONTAINED. 14. TESTING REPORTS NEED TO BE PROVIDED DURING GRADING OPERATIONS. QUANTITIES NOTE FOR CONTRACTORS: QUANTITIES PROVIDED ARE AT THE REQUEST OF THE CITY AND ARE NOT TO BE EXCLUSIVELY USED FOR BIDDING PURPOSES. YOU ARE TO PERFORM YOUR OWN TAKEOFFS. PLEASE QUESTION ANY DISCREPANCIES BY CALLING THE ENGINEER LISTED ON THE COVER SHEET.DRAWING NO. CHECKED BY ENGINEER SHEET NO. FIELD BOOK NO. DRAWN BY REVISIONS NOTICE: McClure Engineering Company waives any and all responsibility and liability for problems which arise from failure to follow these Plans, Specifications, and the engineering intent they convey, or for problems which arise from failure to obtain and/or follow the engineers guidance with respect to any errors, omissions, inconsistencies, ambiguities, or conflicts which are alleged. COPYRIGHT: Copyright and property rights in these documents are expressly reserved by McClure Engineering Company. No reproductions, changes, or copies in any manner shall be made without obtaining prior written consent from McClure Engineering Company. 1360 NW 121ST. Street Clive, Iowa 50325 515-964-1229 fax 515-964-2370 making lives better WILLIAMS POINTE COMMERCIAL PLAT 1 CONSTRUCTION DRAWINGS WAUKEE, IOWA 20218038-000 MAY 2022 T SMITH T SMITH -- . . . . . 06 SE A L I C E ' S R D . SE B R I C K D R . N0 0 ° 1 3 ' 0 8 " E 5 6 6 . 9 7 ' ( M ) N0 0 ° 2 1 ' 1 9 " E 5 6 6 . 9 9 ' ( R ) S89°46'47"E 364.16'(M) S89°41'07"E 364.16'(R) L=153.73'(M&R) R=500.00'( M&R) ∆=17°36'58"(M&R) CHD=S80°58'18"E(M) CHD=S80°52'38"E(R) CHD L=153.12'(M&R) S72° 0 9 ' 4 9 " E 2 3 8 . 8 6 ' ( M ) S72° 0 4 ' 0 9 " E 2 3 8 . 8 3 ' ( R ) L=393.47'(M) L=393.47'(R) R=1285.00'(M&R) ∆=17°32'39"(M) ∆=17°32'39"(R) CHD=S9°03'18"W(M) CHD L=391.94'(M) S0 0 ° 1 6 ' 5 9 " W 9 4 . 6 0 ' ( M ) S0 0 ° 2 2 ' 4 4 " W 9 4 . 4 5 ' ( R ) N89°56'22"W 555.79'(M) N89°50'37"W 555.79'(R) L=66.50'(M) 66.51'(R) R=350.00'(M&R) ∆=10°53'13"(M&R) CHD=N84°29'46"W(M) CHD=N84°24'01"W(R) CHD L=66.40'(M) 66.41'(R) L=61.29'(M&R) R=350.00'(M&R) ∆=10°02'00"(M) ∆=10°02'01"(R) CHD=N84°04'10"W(M) CHD L=61.21'(M) STOP MANHOLE: 1054.05 15" RCP FL OUT N: 1047.85 15" RCP FL IN S: 1047.85 MANHOLE: 1055.02 15" RCP FL OUT N: 1049.27 15" RCP FL IN E: 1049.34 GUTTER: 1045.24 8" CMP FL IN N: 1043.46 24" RCP FL IN N: 1042.34 8" CMP FL IN E: 1042.34 24" RCP FL OUT S: 1042.3 MANHOLE=1046.22 30" RCP FL OUT SSW=1041.28 GUTTER: 1044.67 15" RCP FL OUT W: 1041.09 8" CMP FL IN E: 1041.97 8" CMP FL IN E: 1041.97 GUTTER: 1043.21 15" RCP FL OUT W: 1039.53 8" CMP FL IN E: 1040.66 MANHOLE: 1052.22 PIPE NOT VISIBLE BOTTOM OF WELL=10421.08 8" PVC FL OUT W: 1040.43 MANHOLE: 1048.57 8" PVC FL IN N: 1037.08 8" PVC FL IN E : 1037.08 8" PVC FL OUT S: 1036.98 FES 24 FL = 1043.41 BUILDING MANHOLE: 1048.92 18" RCP FL OUT SW: 1045.27 18" RCP FL IN E: 1045.29 MANHOLE: 1050.54 18" RCP FL OUT W: 1046.95 18" RCP FL IN SE: 1046.98 MANHOLE: 1048.96 24" RCP FL OUT W: 1043.67 24" RCP FL IN E: 1043.75 GUTTER: 1048.94 BOTTOM WELL: 1045.79 MANHOLE: 1051.29 15" RCP FL OUT SW: 1047.79 GUTTER: 1050.90 15" RCP FL IN NE: 1047.20MANHOLE: 1051.41 18" RCP FL OUT NW: 1047.16 GUTTER: 1048.92 24" RCP FL OUT NW: 1044.33 18" RCP FL IN NE: 1044.51 MANHOLE=1046.99 30" RCP FL IN NNE=1041.26 30" RCP FL OUT S=1041.24 MANHOLE: 1055.58 TOP 4" PIPE W: 1050.62 TOP 4" PIPE E: 1050.58 BOTTOM OF WELL: 1050.12 MANHOLE: 1055.38 BOTTOM OF WELL: 1051.73 TWIN 4" PIPES, CAPPED MANHOLE: 1047.33 BOTTOM OF WELL: 1044.23 TWIN 4" PIPES, CAPPED 12" FES STORM SEWER AND OVERLAND FLOWAGE EASEMENT BOOK 2006 PAGE 5703, BOOK 2006 PAGE 5706, BOOK 2006 PAGE 5707 70.00 ROW 31.00 B-B 25.00 B-B 130.16 ROW PARCEL ID: 1235302005 PARCEL ID: 1235351006 TEMPORARY STORM SEWER AND OVERLAND FLOWAGE EASEMENT BOOK 2004, PAGE 16161 50.00' ACCESS EASEMENT BOOK 2017 PAGE 3887 30.00' OVERLAND FLOWAGE EASEMENT BOOK 2004, PAGE 16172 BOOK 2004, PAGE 16177 10.00' PUE BOOK 2004, PAGE 16172 10.00' QWEST EASEMENT BOOK 2010 PAGE 17568 10.00' PUE, BOOK 2006 PAGE 5703, BOOK 2004 PAGE 16159, BOOK 2006 PAGE 5709 10.00' PUE BOOK 2017 PAGE 4498 25.00' INGRESS/EGRESS EASEMENT BOOK 2015 PAGE 5057 50.00' INGRESS/EGRESS, SANITARY SEWER AND WATER MAIN EASEMENT BOOK 2006, PAGE 5703 20.00' RIGHT OF WAY BOOK 2017 PAGE 4495, BOOK 2017 PAGE 3886 TEMPORARY CONSTRUCTION EASEMENT BOOK 2017, PAGE 4498 TEMPORARY CONSTRUCTION EASEMENT BOOK 2017 PAGE 4502 BOOK 2017, PAGE 4499 97.79 B-B 36.00' B-B STORM SEWER AND OVERLAND FLOWAGE EASEMENT BOOK 2006 PAGE 5703, BOOK 2006 PAGE 5706, BOOK 2006 PAGE 5707 TEMPORARY STORM SEWER AND OVERLAND FLOWAGE EASEMENT BOOK 2004, PAGE 16161 50.00' ACCESS EASEMENT BOOK 2017 PAGE 3887 30.00' OVERLAND FLOWAGE EASEMENT BOOK 2004, PAGE 16172 BOOK 2004, PAGE 16177 10.00' PUE BOOK 2004, PAGE 16172 10.00' QWEST EASEMENT BOOK 2010 PAGE 17568 10.00' PUE, BOOK 2006 PAGE 5703, BOOK 2004 PAGE 16159, BOOK 2006 PAGE 5709 10.00' PUE BOOK 2017 PAGE 4498 25.00' INGRESS/EGRESS EASEMENT BOOK 2015 PAGE 5057 50.00' INGRESS/EGRESS, SANITARY SEWER AND WATER MAIN EASEMENT BOOK 2006, PAGE 5703 20.00' RIGHT OF WAY BOOK 2017 PAGE 4495, BOOK 2017 PAGE 3886 TEMPORARY CONSTRUCTION EASEMENT BOOK 2017, PAGE 4498 TEMPORARY CONSTRUCTION EASEMENT BOOK 2017 PAGE 4502 BOOK 2017, PAGE 4499 36.00' B-B STORM SEWER AND OVERLAND FLOWAGE EASEMENT BOOK 2006 PAGE 5703, BOOK 2006 PAGE 5706, BOOK 2006 PAGE 5707 TEMPORARY STORM SEWER AND OVERLAND FLOWAGE EASEMENT BOOK 2004, PAGE 16161 50.00' ACCESS EASEMENT BOOK 2017 PAGE 3887 30.00' OVERLAND FLOWAGE EASEMENT BOOK 2004, PAGE 16172 BOOK 2004, PAGE 16177 10.00' PUE BOOK 2004, PAGE 16172 10.00' QWEST EASEMENT BOOK 2010 PAGE 17568 10.00' PUE, BOOK 2006 PAGE 5703, BOOK 2004 PAGE 16159, BOOK 2006 PAGE 5709 20.00' OVERLAND FLOWAGE EASEMENT, BOOK 2006 PAGE 5703, BOOK 2004 PAGE 16159, BOOK 2004, PAGE 16164 10.00' PUE BOOK 2017 PAGE 4498 25.00' INGRESS/EGRESS EASEMENT BOOK 2015 PAGE 5057 50.00' INGRESS/EGRESS, SANITARY SEWER AND WATER MAIN EASEMENT BOOK 2006, PAGE 5703 20.00' RIGHT OF WAY BOOK 2017 PAGE 4495, BOOK 2017 PAGE 3886 20.00' RIGHT OF WAY BOOK 2017 PAGE 3887 BOOK 2017 PAGE 4499 BOOK 2017 PAGE 4500 TEMPORARY CONSTRUCTION EASEMENT BOOK 2017, PAGE 4498 TEMPORARY CONSTRUCTION EASEMENT BOOK 2017 PAGE 4502 BOOK 2017, PAGE 4499 36.00' B-B Des Moines, Iowa DRAWING NO. CHECKED BY ENGINEER SHEET NO. FIELD BOOK NO. DRAWN BY REVISIONS NOTICE: McClure Engineering Company waives any and all responsibility and liability for problems which arise from failure to follow these Plans, Specifications, and the engineering intent they convey, or for problems which arise from failure to obtain and/or follow the engineers guidance with respect to any errors, omissions, inconsistencies, ambiguities, or conflicts which are alleged. COPYRIGHT: Copyright and property rights in these documents are expressly reserved by McClure Engineering Company. No reproductions, changes, or copies in any manner shall be made without obtaining prior written consent from McClure Engineering Company. 1360 NW 121ST. Street Clive, Iowa 50325 515-964-1229 fax 515-964-2370 making lives better WILLIAMS POINTE COMMERCIAL PLAT 1 CONSTRUCTION DRAWINGS WAUKEE, IOWA 20218038-000 MAY 2022 T SMITH T SMITH -- . . . . . 063EX-01 EXISTING CONDITIONS N: \ P r o j e c t s \ W A K 2 0 2 1 8 0 3 8 \ D w g s \ P l a n s \ S a n i t a r y C o n s t r u c t i o n D r a w i n g s \ E X - 0 1 . d w g 10 / 2 6 / 2 0 2 2 9 : 0 9 A M 25 500 GRAPHIC SCALE 100 NORTH 10.0000' PUE BOOK 2004 PAGE 16159 (TO BE VACATED) 10.00' PUE BOOK 2004 PAGE 16172 (TO BE VACATED) 10.00' PUE BOOK 2006 PAGE 5709 SE A L I C E ' S R D . SE B R I C K D R . SW-301 SW-301 EXISTING-SW-301 94,861 SF 2.18 AC LOT 1 298,241 SF 6.85 AC OUTLOT X S89°46'47"E 285.34' S89°46'47"E 78.82' L=153.73' R=500.00' ∆=17°36'58" CHD=S80°58'18"E CHD L=153.12' S72° 0 9 ' 4 9 " E 238.8 6 ' L=222.77' R=1285.00' ∆=9°55'58" CHD=S12°51'39"W CHD L=222.49' L=170.70' R=1285.00' ∆=7°36'41" CHD=S4°05'19"W CHD L=170.58' S00°16'59"W 94.60' N89°56'22"W 555.79' L=66.50' R=350.00' ∆=10°53'13" CHD=N84°29'46"W CHD L=66.40' L=61.29' R=350.00' ∆=10°02'00" CHD=N84°04'10"W CHD L=61.21' N0 0 ° 1 3 ' 0 8 " E 56 6 . 9 7 ' N71° 3 3 ' 2 2 " W 429.9 9 ' N0 0 ° 0 0 ' 0 0 " E 17 8 . 3 6 ' STOP MANHOLE: 1054.05 15" RCP FL OUT N: 1047.85 15" RCP FL IN S: 1047.85 MANHOLE: 1055.02 15" RCP FL OUT N: 1049.27 15" RCP FL IN E: 1049.34 GUTTER: 1045.24 8" CMP FL IN N: 1043.46 24" RCP FL IN N: 1042.34 8" CMP FL IN E: 1042.34 24" RCP FL OUT S: 1042.3 MANHOLE=1046.22 30" RCP FL OUT SSW=1041.28 GUTTER: 1044.67 15" RCP FL OUT W: 1041.09 8" CMP FL IN E: 1041.97 8" CMP FL IN E: 1041.97 GUTTER: 1043.21 15" RCP FL OUT W: 1039.53 8" CMP FL IN E: 1040.66 MANHOLE: 1052.22 PIPE NOT VISIBLE BOTTOM OF WELL=10421.08 8" PVC FL OUT W: 1040.43 MANHOLE: 1048.57 8" PVC FL IN N: 1037.08 8" PVC FL IN E : 1037.08 8" PVC FL OUT S: 1036.98 FES 24 FL = 1043.41 BUILDING MANHOLE: 1048.92 18" RCP FL OUT SW: 1045.27 18" RCP FL IN E: 1045.29 MANHOLE: 1050.54 18" RCP FL OUT W: 1046.95 18" RCP FL IN SE: 1046.98 MANHOLE: 1048.96 24" RCP FL OUT W: 1043.67 24" RCP FL IN E: 1043.75 GUTTER: 1048.94 BOTTOM WELL: 1045.79 MANHOLE: 1051.29 15" RCP FL OUT SW: 1047.79 GUTTER: 1050.90 15" RCP FL IN NE: 1047.20MANHOLE: 1051.41 18" RCP FL OUT NW: 1047.16 GUTTER: 1048.92 24" RCP FL OUT NW: 1044.33 18" RCP FL IN NE: 1044.51 MANHOLE=1046.99 30" RCP FL IN NNE=1041.26 30" RCP FL OUT S=1041.24 MANHOLE: 1055.58 TOP 4" PIPE W: 1050.62 TOP 4" PIPE E: 1050.58 BOTTOM OF WELL: 1050.12 MANHOLE: 1055.38 BOTTOM OF WELL: 1051.73 TWIN 4" PIPES, CAPPED MANHOLE: 1047.33 BOTTOM OF WELL: 1044.23 TWIN 4" PIPES, CAPPED 12" FES 70.00 ROW 31.00 B-B 25.00 B-B 130.16 ROW 97.79 B-B DRAWING NO. CHECKED BY ENGINEER SHEET NO. FIELD BOOK NO. DRAWN BY REVISIONS NOTICE: McClure Engineering Company waives any and all responsibility and liability for problems which arise from failure to follow these Plans, Specifications, and the engineering intent they convey, or for problems which arise from failure to obtain and/or follow the engineers guidance with respect to any errors, omissions, inconsistencies, ambiguities, or conflicts which are alleged. COPYRIGHT: Copyright and property rights in these documents are expressly reserved by McClure Engineering Company. No reproductions, changes, or copies in any manner shall be made without obtaining prior written consent from McClure Engineering Company. 1360 NW 121ST. Street Clive, Iowa 50325 515-964-1229 fax 515-964-2370 making lives better WILLIAMS POINTE COMMERCIAL PLAT 1 CONSTRUCTION DRAWINGS WAUKEE, IOWA 20218038-000 MAY 2022 T SMITH T SMITH -- . . . . . 064GR-01 CONTROL PLAN EROSION & SEDIMENT N: \ P r o j e c t s \ W A K 2 0 2 1 8 0 3 8 \ D w g s \ P l a n s \ S a n i t a r y C o n s t r u c t i o n D r a w i n g s \ G R - 0 1 . d w g 10 / 2 6 / 2 0 2 2 9 : 1 0 A M 25 500 GRAPHIC SCALE 100 NORTH 30' LA N D S C A P E B U F F E R SETB A C K 30 ' F R O N T SE T B A C K 30 ' R E A R S E T B A C K DUMPSTER LINED OR ROLL OFF WASH OUT STAGING AREA / EQUIPMENT STORAGE PORTABLE RESTROOM W PR ROCK CONSTRUCTION ENTRANCE 24' x 60 ' SILT FENCE (TYP) ITEM QUANTITY UNIT SILT FENCE 1550 LINEAR FEET BELOW GRADE INTAKE PROTECTION (POST PAVING)5 EACH ROCK CONSTRUCTION ENTRANCE 1 EACH STAGING AREA 1 EACH DUMPSTER 1 EACH PORTABLE RESTROOM 1 EACH WASH OUT 1 EACH DISTURBED AREA 1.95 ACRE TOP SOIL STOCKPILE LOCATION APPROXIMATE LIMITS OF DISTRURBANCE DISCHARGE POINT #2 - TO SUGAR CREEK TRIBUTARIES DISCHARGE POINT #1 - TO SUGAR CREEK TRIBUTARIES ST-100 1030 1035 1040 1045 1050 1055 1060 1030 1035 1040 1045 1050 1055 1060 100+00 10 4 8 . 5 3 E G 10 4 8 . 5 3 F G 10 4 9 . 8 6 F G 10 4 9 . 8 6 E G 101+00 10 5 0 . 1 8 E G 10 5 0 . 1 8 F G 10 5 0 . 9 7 F G 10 5 0 . 9 7 E G 102+00 10 5 1 . 1 8 E G 10 5 1 . 1 8 F G 10 4 9 . 1 2 F G 10 4 9 . 1 2 E G 103+00 10 4 8 . 5 2 E G 10 4 8 . 5 2 F G 10 4 9 . 0 1 F G 10 4 9 . 0 1 E G 104+00 10 4 9 . 1 8 E G 10 4 9 . 1 8 F G 10 4 9 . 1 5 F G 10 4 9 . 1 5 E G 104+91 10 4 9 . 1 0 E G 10 4 9 . 1 0 F G SS M H - 1 0 1 ( S W - 3 0 1 , 4 8 " D I A . ) PI P E S T A = 1 0 0 + 3 0 . 7 3 RI M = 1 0 4 9 . 5 3 ( 1 2 . 3 2 ' D E P T H ) IN V . I N ( E ) = 1 0 3 8 . 0 0 P - 1 0 2 IN V . O U T ( S ) = 1 0 3 7 . 2 1 P - 1 0 1 SS M H - 1 0 2 ( S W - 3 0 1 , 4 8 " D I A . ) PI P E S T A = 1 0 0 + 9 6 . 0 9 RI M = 1 0 5 0 . 1 3 ( 1 1 . 8 0 ' D E P T H ) IN V . I N ( N ) = 1 0 3 8 . 5 8 P - 1 0 3 IN V . O U T ( W ) = 1 0 3 8 . 3 3 P - 1 0 2 P-102 65.43 LF 8" PVC @ 0.50% P-103 178.43 LF 8" PVC @ 0.50% SS M H - 1 0 3 ( S W - 3 0 1 , 4 8 " D I A . ) PI P E S T A = 1 0 2 + 7 4 . 5 2 RI M = 1 0 4 8 . 4 8 ( 9 . 2 0 ' D E P T H ) IN V . I N ( N ) = 1 0 3 9 . 7 3 P - 1 0 4 IN V . O U T ( S ) = 1 0 3 9 . 4 8 P - 1 0 3 P-104 181.12 LF 8" PVC @ 0.50% SS M H - 1 0 4 ( S W - 3 0 1 , 4 8 " D I A . ) PI P E S T A = 1 0 4 + 5 5 . 6 4 RI M = 1 0 4 9 . 1 5 ( 8 . 7 9 ' D E P T H ) IN V . O U T ( S ) = 1 0 4 0 . 6 3 P - 1 0 4 EXISTING-01 (EXISTING-SW-301, 48" DIA.) PIPE STA = 100+05.00 RIM = 1048.62 (11.54' DEPTH) INV. IN (N) = 1037.08 P-101 P-101 25.73 LF 8" PVC @ 0.50% + 10 0 00 + 10 1 00 + 10 2 00 + 10 3 00 + 10 4 00 + 10 4 91 STOP SSMH-102 (SW-301, 48" DIA.) PIPE STA = 100+96.09 RIM = 1050.13 (11.80' DEPTH) INV. IN (N) = 1038.58 P-103 INV. OUT (W) = 1038.33 P-102 SSMH-101 (SW-301, 48" DIA.) PIPE STA = 100+30.73 RIM = 1049.53 (12.32' DEPTH) INV. IN (E) = 1038.00 P-102 INV. OUT (S) = 1037.21 P-101 SSMH-104 (SW-301, 48" DIA.) PIPE STA = 104+55.64 RIM = 1049.15 (8.79' DEPTH) INV. OUT (S) = 1040.63 P-104 SSMH-103 (SW-301, 48" DIA.) PIPE STA = 102+74.52 RIM = 1048.48 (9.20' DEPTH) INV. IN (N) = 1039.73 P-104 INV. OUT (S) = 1039.48 P-103 P-104, 8" PVC P-103, 8" PVC P-102, 8" PVC SE ALICES ROAD PROPOSED 30' PRIVATE SANITARY EASEMENT 102° 102° MANHOLE: 1048.92 18" FL OUT SW: 1045.27 MANHOLE: 1048.96 24" RCP FL OUT W: 1043.67 24" RCP FL IN E: 1043.75 GUTTER: 1048.94 BOTTOM WELL: 1045.79 GUTTER: 1045.24 8" CMP FL IN N: 1043.46 24" RCP FL IN N: 1042.34 8" CMP FL IN E: 1042.34 24" RCP FL OUT S: 1042.3 GUTTER: 1045.43 24" RCP FL IN N: 1041.68 24" RCP FL IN E: COULD NOT DIP MANHOLE=1046.22 30" RCP FL S=1041.28 GUTTER: 1044.67 12" RCP FL OUT W: 1041.09 8" CMP FL IN E: 1041.97 8" CMP FL IN E: 1041.97 GUTTER: 1043.21 12" RCP FL OUT W: 1039.53 8" CMP FL IN E: 1040.66FES 24 FL = 1043.41 GUTTER: 1048.92 24" RCP FL OUT NW: 1044.33 18" RCP FL IN NE: 1044.51 SANITARY MANHOLE: 1048.57 8" PVC FL IN N: 1037.08 8" PVC FL IN E : 1037.08 8" PVC FL OUT S: 1036.98 PRIVATE DRIVE CONTRACTOR TO FIELD VERIFY LOCATION AND ELEVATION OF EXISTING SANITARY SEWER STUB DRAWING NO. CHECKED BY ENGINEER SHEET NO. FIELD BOOK NO. DRAWN BY REVISIONS NOTICE: McClure Engineering Company waives any and all responsibility and liability for problems which arise from failure to follow these Plans, Specifications, and the engineering intent they convey, or for problems which arise from failure to obtain and/or follow the engineers guidance with respect to any errors, omissions, inconsistencies, ambiguities, or conflicts which are alleged. COPYRIGHT: Copyright and property rights in these documents are expressly reserved by McClure Engineering Company. No reproductions, changes, or copies in any manner shall be made without obtaining prior written consent from McClure Engineering Company. 1360 NW 121ST. Street Clive, Iowa 50325 515-964-1229 fax 515-964-2370 making lives better WILLIAMS POINTE COMMERCIAL PLAT 1 CONSTRUCTION DRAWINGS WAUKEE, IOWA 20218038-000 MAY 2022 T SMITH T SMITH -- . . . . . 065SA-01 AND PROFILE SANITARY PLAN NORTH 20'40'0 GRAPHIC SCALE 80' LOT 1 2.18 AC OUTLOT X 6.85 AC SE A L I C E ' S R D . EXISTING SW-505 FES 94,861 SF 2.18 AC LOT 1 298,241 SF 6.85 AC OUTLOT X S89°46'47"E 285.34' S89°46'47"E 78.82' CHD L=153.12' S72°0 9 ' 4 9 " E 238.8 6 ' N0 0 ° 1 3 ' 0 8 " E 56 6 . 9 7 ' N71° 3 3 ' 2 2 " W 429.9 9 ' N0 0 ° 0 0 ' 0 0 " E 17 8 . 3 6 ' P- 1 0 4 , 8 " P V C P-1, 15" RCP EX-01, 15" RCP GUTTER: 1044.67 15" RCP FL OUT W: 1041.09 8" CMP FL IN E: 1041.97 8" CMP FL IN E: 1041.97 GUTTER: 1043.21 15" RCP FL OUT W: 1039.53 8" CMP FL IN E: 1040.66 BUILDING 12" FES 1045104210431044 1046 1047 104 8 FES-1, FES PIPE STA = 100+48.63 INV. OUT (W) = 1040.65 P-1 P-1 46.13 LF 15" RCP @ 2.06% -3 1 . 9 1 % -3 0 . 6 1 % -2.04% 1030 1035 1040 1045 1050 1055 1060 1030 1035 1040 1045 1050 1055 1060 99+75 E G F G 100+00 E G F G 10 4 5 . 9 2 F G 10 4 5 . 9 2 E G 101+00 E G F G P-1 46.13 LF 15" RCP @ 2 . 0 6 % FE S - 1 , F E S ST A = 1 0 0 + 4 8 . 6 3 RI M = 1 0 4 1 . 4 1 IN V . O U T ( W ) = 1 0 4 0 . 6 5 P - 1 ST R C - 2 7 , E X I S T I N G S W - 5 0 5 ST A = 1 0 0 + 0 2 . 5 0 RI M = 1 0 4 3 . 8 1 IN V . I N ( E ) = 1 0 3 9 . 7 0 P - 1 IN V . O U T ( W ) = 1 0 3 9 . 5 3 E X - 0 1 DRAWING NO. CHECKED BY ENGINEER SHEET NO. FIELD BOOK NO. DRAWN BY REVISIONS NOTICE: McClure Engineering Company waives any and all responsibility and liability for problems which arise from failure to follow these Plans, Specifications, and the engineering intent they convey, or for problems which arise from failure to obtain and/or follow the engineers guidance with respect to any errors, omissions, inconsistencies, ambiguities, or conflicts which are alleged. COPYRIGHT: Copyright and property rights in these documents are expressly reserved by McClure Engineering Company. No reproductions, changes, or copies in any manner shall be made without obtaining prior written consent from McClure Engineering Company. 1360 NW 121ST. Street Clive, Iowa 50325 515-964-1229 fax 515-964-2370 making lives better WILLIAMS POINTE COMMERCIAL PLAT 1 CONSTRUCTION DRAWINGS WAUKEE, IOWA 20218038-000 MAY 2022 T SMITH T SMITH -- . . . . . 066ST-01 GENERAL LAYOUT N: \ P r o j e c t s \ W A K 2 0 2 1 8 0 3 8 \ D w g s \ P l a n s \ S a n i t a r y C o n s t r u c t i o n D r a w i n g s \ S T - 0 1 . d w g 10 / 2 6 / 2 0 2 2 9 : 1 4 A M 25 500 GRAPHIC SCALE 100 NORTH NOTE: PROPOSED PIPE AND STORMWATER FLOWAGE EASEMENT MAY BE ABANDONED TO ACCOMMODATE FUTURE DEVELOPMENT IN THIS SUBDIVISION. COST OF ABANDONMENT SHALL BE INCURRED BY FUTURE TENANT AND RELOCATED STORM SEWER SHALL BE PROVIDED TO CONVEY LOT 1'S ALLOWABLE DISCHARGE TIE TO EXISTING SW-505 PROPOSED FL = 1039.70 TOP OF SWALE = 1045.35 100-YEAR ELEVATION = 1044.26EMERGENCY OVERFLOW ELEVATION = 1045.00 REMOVE AND REPLACE 25'± OF 5' SIDEWALK FLOOR FINISH 00'-0" FASCIA 26'-0" TOP OF PARAPET 23'-4" 1 WEST ELEVATION SCALE: 1/8" = 1'-0" 12'-0" 11 STOREFRONT BEYOND 1320 SF 74 SF 76 SF 612 SF 342 SF FAUX BRICK CONC. BLK FAUX STONE EIFS WINDOWS 54.1% 3.1% 3.1% 25.4% 14.3% TOTALS 2438 100.0% MATERIAL QUANITY LEGEND: FLOOR FINISH 00'-0" TOP OF PARAPET 26'-0" 1 2 SOUTH ELEVATION SCALE: 1/8" = 1'-0" TOP OF PARAPET 21'-8" TOP OF BULKHEAD 12'-0" TOP OF OPENING 14'-0" OPEN TO BEYOND T.O. PARAPET 23-4" TOP OF PARAPET 25-4" BEYOND BEYOND 2891 140 SF 210 SF 293 SF 324 SF 72 SF. FAUX BRICK CONC. BLK FAUX STONE EIFS OVERH'D DOOR DOORS 73.5% 3.6% 5.4% 7.5% 8.2% 1.8% TOTALS 3930 SF.100.0% MATERIAL QUANITY LEGEND: TOP OF PARAPET 23'-4" FLOOR FINISH 00'-0" T.O. FASCIA 26'-0" B.O. SIGN BULKHEAD 112'-0" TOP OF PARAPET 23'-4" 4 NORTH ELEVATION SCALE: 1/8" = 1'-0" XXXX114'-0" T.O. PARAPET 21-8" OPEN TO BEYOND TOP OF PARAPET 25'-4" 3047 SF 136 SF 21O SF 308 SF 96 SF 166 SF. FAUX BRICK CONC. BLK FAUX STONE EIFS MAN DOORS OVERH'D DOORS 76.9% 3.4% 5.3% 7.8% 2.4% 4.2% TOTALS 3963 SF.100.0% MATERIAL QUANITY LEGEND: FLOOR FINISH U00'-0" TOP OF PARAPET 23'-4" 3 EAST ELEVATION SCALE: 1/8" = 1'-0" BOTTOM OF RELIEF 14'-0"1811 SF 132 SF 48 SF. FAUX BRICK CONC. BLK MAN DOORS 77.9% 5.7% 2.1% TOTALS 2324 SF.100.0% MATERIAL QUANITY LEGEND: 333 SF.OVERH'D DOORS 14.3% EXTERIOR FINISHES KEY 1 2 3 4 5 6 THIN BRICK BY ENICOTT BRICK EIFS ALUM/GLASS STOREFRONT CAP FLASHING MAN DOOR GLAZED BLACK - SN8 GLAZED BLACK GLAZED GRAY - SN4 GLAZED GRAY PPG #287 CUSTOM BLUE DARK ANODIZE DARK BRONZE PAINT TO MATCH ADJACENT COLOR PPG #430 DARK GRAY MODULAR SIZE - - - - 7 8 9 10 OVERHEAD DOOR SIGN WALL MOUNTED LIGHT MECHANICAL GRILLE PAINT PPG #287 CUSTOM BLUE PROPOSED SIGN LOCATION. SHOWN FOR REFERENCE ONLY. SIGN VENDOR TO INSTALL UNDER SEPARATE PERMIT. GC TO PROVIDE EXTERIOR GRADE PLYWOOD SUBSTRATE AT ALL SIGN LOCATIONS. DARK BRONZE PAINT TO MATCH ADJACENT COLOR MATERIAL COLOR REMARKS MODULAR SIZE 11 FAUX STONE WOLF CREEK COUNTRY LEDGESTONE WITH MORTAR BY BY CULTURED STONE 12 PAINTED SMOOTH FACE CONC. BLOCK (CUT SOAPS) PPG #287 CUSTOM BLUE SMOOTH FACE 6-2150Xl, SPEEDHIDE EXT.STATIN FAUX BRICK BY ENDICOTT BRICK 13 FAUX BRICK BY CULTURE STONE CO. GLAZED BLACK - SNB (DARK GRAY) MODULAR SIZE - SOLDIER COURSES 14 METAL SCUPPER AND PAINT TO MATCH LIGHT GRAY BRICK SEE DETAIL 1 ON SHEET A-103 6 STONE SAMPLE VIEW SCALE: NON SUEDE LIMESTONE BY CULTURED STONE COMPANY "NIGHTFALL" COLOR WATER TABLE BY CULTURED STONE PROVIDE 8"DIA. X 6'-0"H CONC. FILLED PIPE BOLLARD PROTECTION. NOTE: CONTRACTOR TO INSTALL NO TRESPASSING SIGN ON DUMPSTER. 8"DIA. PIPE BOLLARD PAINT YELLOW GALV MTL GATE - PAINT TO MATCH BLDG. 18"L X 3/4"D CANE BOLT PAD LOCK AND HASP. DIAG. BRACING @ EACH PANEL. 24"L X 3/4"D CANE BOLT TYP @ EA GATE PANEL. PROVIDE 6" X 4'-0" HIGH PIPE BOLLARD PROTECTION AT REAR OF DUMPSTER CAVITY. PAINT "SAFETY YELLOW" TYP PAINT SAFETY YELLOW DUMPSTER DUMPSTER DUMPSTER 6' - 0 " 30'-812" 11 ' - 4 " 8" 8" 6" 10 ' - 0 " 812"3'-8"3'-8"3'-8"3'-8"3'-8"3'-8"3'-8" 3'-8" 8" 30'-8" 6' - 0 " 10'-4"1'-4"17'-8" 1 DUMPSTER ENCLOSURE PLAN VIEW SCALE: 1/4" = 1'-0" 3 DUMPSTER ENCLOSURE ELEVATION SCALE: 1/4" = 1'-0" 5 DUMPSTER ENCLOSURE ELEVATION SCALE: 1/4" = 1'-0" 8" SMOOTH-FACE SOLID CORE CMU WALL CAP PAINT TO MATCH FINISH 1 8" SMOOTH-FACE CMU PAINT TO MATCH FINISH 1 8"DIA. PIPE BOLLARD PAINT YELLOW 8" SMOOTH-FACE SOLID CORE CMU WALL CAP PAINT TO MATCH FINISH 1 8" SMOOTH-FACE CMU PAINT TO MATCH FINISH 1 8" SMOOTH-FACE CMU PAINT TO MATCH FINISH 1 WI L L I A M S P O I N T E S. E . BR I C K R O A D WA U K E E , I O W A GE R B E R C O L L I S I O N 45 SPYGLASS DRIVE LITTLETON, COLORADO 80123 VOICE: 303.881-8925 NORMHERMAN@ARCODEV.COM ARCHITECT NORMAN L. HERMAN A-211 EXTERIOR ELEVATIONS