Loading...
HomeMy WebLinkAbout2023-03-06 J04 Cove at Kettlestone Plat 4 Lot 1_Site PlanAGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: March 6, 2023 AGENDA ITEM:Consideration of approval of a resolution approving a site plan for Cove at Kettlestone Plat 4 Lot 1 (1450 SE University Avenue) FORMAT:Resolution SYNOPSIS INCLUDING PRO & CON: Hawthorne Pointe, LLC requests approval of a site plan for a multi-tenant commercial / office building located south of SE University Avenue and west of SE Waco Place. The building is proposed to be 11,550-square feet in area and 22-feet in height. The applicant is proposed 87 parking spaces where 86 are required, including the required number of bicycle parking, per Kettlestone Design Guidelines. The building will be constructed primarily of traditional stucco, brick and glazing. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning Commission reviewed this project at the February 28, 2023, Commission Meeting and recommended approval subject to remaining staff comments: Approval of a Site Plan for Cove at Kettlestone Plat 4, Lot 1 (1450 SE University Ave) City Planner, Bill Mettee, introduced the request for approval of a site plan related to a commercial/office building as submitted by the applicant, Hawthorne Pointe, LLC. The property is generally located south of SE University Avenue and west of SE Waco place/98th Street, and contains approximately 1.73 acres. Mr. Mettee advised that the project includes the construction of a multi-tenant building approximately 11,550 square feet in area and one story, 22 feet, in height. A trash enclosure is proposed on the south west corner of the site. Mr. Mettee explained that access is available through several shared accesses with neighboring development as well as directly into the site off of SE Bishop Drive. 5-foot-wide sidewalks in and around the development will allow for pedestrian access. Utilities are available to serve the site, and storm water detention is managed by underground detention as well as in a basin to the southwest of the site. Parking requirements, landscaping, open space, elevation, and lighting plan requirements have all been met at this time. Staff recommends approval subject to any remaining Staff comments. Commissioner Broderick questioned if it could be retail usage as well. Mr. Mettee advised that there are no known tenants at this time, and that retail is an approved usage in this zoning district. J4 Commissioner Beenken questioned if the full access drive access to SE University Avenue is the one currently located at the car wash. Mr. Mettee advised that was correct. Commissioner Koelker questioned if there would be another access to SE University Avenue provided. Mr. Mettee advised no. Commissioner Broderick questioned if there would be enough space for waste services to access the enclosure. A representative for the applicant, Corey Marsh, advised that the dumpster would need to be wheeled out of the enclosure for pick up. Commissioner Koelker moved to approve the site plan for Cove at Kettlestone Plat 4, Lot 1(1450 SE University Ave) subject to any remaining Staff comments. Commissioner Tessau seconded the motion. Ayes: Koelker, Beenken, Broderick, Tessau, and Lohse. Nays: none. Motion Carried. STAFF REVIEW AND COMMENT: Staff recommends approval of the site plan subject to remaining staff comments. RECOMMENDATION: Approve the resolution subject to remaining staff comments. ATTACHMENTS: I. Proposed Resolution II. Staff Report III. Site Plan & Elevations PREPARED BY:Bill Mettee, Planner REVIEWED BY: THE CITY OF WAUKEE, IOWA RESOLUTION 2023- APPROVING THE SITE PLAN FOR COVE AT KETTLESTONE PLAT 4 LOT 1 (1450 SE UNIVERSITY AVENUE) IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Site Plan for Cove at Kettlestone Plat 4 Lot 1, subject to remaining staff comments on February 28, 2023; AND, WHEREAS, the Site Plan for Cove at Kettlestone Plat 4 Lot 1 is in general conformance with §160 – Site and Building Development Standards Ordinance of the Waukee Municipal Code; AND, WHEREAS, the Site Plan for Cove at Kettlestone Plat 4 Lot 1 is in general conformance with §161 – Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND, NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 6th day of March, 2023 that the Site Plan for Cove at Kettlestone Plat 4 Lot 1 is approved subject to remaining staff comments. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Anna Bergman Pierce R. Charles Bottenberg Chris Crone Larry R. Lyon Ben Sinclair BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m KM M LJ M KS 11 - 0 7 - 2 2 ## # ' 12 1 . 1 2 2 2 . 0 1 A C1 0 0 121.1222.01A C100 CO V E A T K E T T L E S T O N E P L A T 4 , L O T 1 TI T L E S H E E T WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 01 - 1 0 - 2 3 01 - 3 1 - 2 3 02 - 1 4 - 2 3 02 - 2 8 - 2 3 KS LJ M LJ M LJ M 3456 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 1 \ 1 2 1 . 1 2 2 2 . 0 1 A \ C A D D \ S P _ 1 2 1 1 2 2 2 A _ T S H . d w g LO G A N M Y E R S , TI T L E S H E E T , 20 2 3 / 0 2 / 2 8 , 3: 2 7 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) I hereby certify that this engineering document was prepared by me or under my direct personal supervision and that I am a duly licensed Professional Engineer under the laws of the State of Iowa. Korey M. Marsh, P.E.Date License Number P25347 My License Renewal Date is December 31, 2024 Pages or sheets covered by this seal: KOREY M. MARSH P25347 D P R O F E L NS E ICE IONAL EN G I N E ER AIOW SS P E F RO S S O N LA I AC PNALCDS CARH E CE T TII A ETST F IO AW O License Expires: June 30, 2023 CLAY R. SCHNECKLOTH 512 LANDSCAPE ARCHITECT NO. Clay R. Schneckloth, PLA License Number Pages or sheets covered by this seal: 512 Date I hereby certify that the portion of this technical submission described below was prepared by me or under my direct supervision and responsible charge. I am a duly licensed Professional Landscape Architect under the laws of the State of Iowa. OWNER/DEVELOPER HAWTHORNE POINTE, LLC 7500 UNIVERSITY AVE, SUITE 2112 WEST DES MOINES, IA 50266 CONTACT: JARED T. JOHNSON JR PHONE: (515) 556-0124 ENGINEER SNYDER & ASSOCIATES, INC. 2727 SW SNYDER BOULEVARD ANKENY, IOWA 50023 (515)964-2020 KOREY MARSH, PE SUBMITTAL DATES 1ST SUBMITTAL 11/08/2022 2ND SUBMITTAL 11/23/2022 3RD SUBMITTAL 12/07/2022 4TH SUBMITTAL 01/10/2023 5TH SUBMITTAL 01/31/2023 6TH SUBMITTAL 02/14/2023 7TH SUBMITTAL 02/28/2023 BISHOP DRIVE SE BISHOP DRIVE SE W A C O P L A C E SE UNIVERSITY AVE SE ROSEWOOD CT C500 C100-C401, C600-C602 SITE PLANS FOR COVE AT KETTLESTONE PLAT 4, LOT 1 1450 SE UNIVERSITY AVE CITY OF WAUKEE, DALLAS COUNTY, IOWA VICINITY MAP PROJECT LOCATION Sheet List Table Sheet Number Sheet Title C100 TITLE SHEET C101 PROJECT INFORMATION C200 DIMENSION PLAN C300 UTILITY PLAN C301 STORM SEWER PLAN C400 EROSION & SEDIMENT CONTROL PLAN C401 DETAILED GRADING PLAN C500 PLANTING PLAN C600 SITE DETAILS C601 SITE DETAILS C602 SITE DETAILS BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m KM M LJ M KS 11 - 0 7 - 2 2 ## # ' 12 1 . 1 2 2 2 . 0 1 A C1 0 1 121.1222.01A C101 CO V E A T K E T T L E S T O N E P L A T 4 , L O T 1 PR O J E C T I N F O R M A T I O N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 01 - 1 0 - 2 3 01 - 3 1 - 2 3 02 - 1 4 - 2 3 02 - 2 8 - 2 3 KS LJ M LJ M LJ M 3456 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 1 \ 1 2 1 . 1 2 2 2 . 0 1 A \ C A D D \ S P _ 1 2 1 1 2 2 2 A _ T S H . d w g LO G A N M Y E R S , PR O J E C T I N F O R M A T I O N , 20 2 3 / 0 2 / 2 8 , 3: 2 7 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) NOTES A.NOTIFY UTILITY PROVIDERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES AND COORDINATE WITH UTILITY PROVIDERS AS NECESSARY DURING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXISTENCE, EXACT LOCATION, AND DEPTH OF ALL UTILITIES. PROTECT ALL UTILITY LINES AND STRUCTURES NOT SHOWN FOR REMOVAL OR MODIFICATION. ANY DAMAGES TO UTILITY ITEMS NOT SHOWN FOR REMOVAL OR MODIFICATION SHALL BE REPAIRED TO THE UTILITY OWNER'S SPECIFICATIONS AT THE CONTRACTOR'S EXPENSE. B.CONSTRUCTION OF ALL STREET AND UTILITY IMPROVEMENTS SHALL CONFORM TO THE 2020 WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS, 2023 STATEWIDE URBAN DESIGN AND SPECIFICATIONS (SUDAS) AND THE SOILS REPORTS PREPARED BY OTHERS. C.LENGTH OF UTILITIES SHOWN ON PLANS ARE DIMENSIONED FROM CENTERLINE OF STRUCTURE TO CENTERLINE OF STRUCTURE. D.ALL TRAFFIC CONTROL SHALL BE PROVIDED IN ACCORDANCE WITH REQUIREMENTS SET FORTH IN THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). WHEN CONSTRUCTION ACTIVITIES OBSTRUCT PORTIONS OF THE ROADWAY, FLAGGERS SHALL BE PROVIDED. FLAGGERS SHALL CONFORM TO THE MUTCD IN APPEARANCE, EQUIPMENT AND ACTIONS. THE CONTRACTOR SHALL NOTIFY THE CITY OF WAUKEE AT LEAST ONE WEEK PRIOR TO ANY ANTICIPATED LANE CLOSURE. E.NOTIFY OWNER, ENGINEER, CITY OF WAUKEE AT LEAST 48 HOURS PRIOR TO BEGINNING WORK. CONTRACTOR SHALL ALSO NOTIFY THE CITY OF WAUKEE PUBLIC WORKS DEPARTMENT AT LEAST 48 HOURS PRIOR TO ANY PLANNED WEEKEND OR HOLIDAY WORK. F.CONSTRUCT MANHOLES AND APPURTENANCES AS WORK PROGRESSES. BACKFILL WITH SUITABLE MATERIAL AND COMPACT TO 95% MAXIMUM DENSITY. G.IN THE EVENT OF A DISCREPANCY BETWEEN THE QUANTITY ESTIMATES AND THE DETAILED PLANS, THE DETAILED PLANS SHALL GOVERN. H.ALL FIELD TILES ENCOUNTERED DURING CONSTRUCTION SHALL BE RECONNECTED OR REPAIRED AND NOTED ACCORDINGLY ON THE AS-BUILT DOCUMENTS. I. DIMENSIONS, BUILDING LOCATION, UTILITIES AND GRADING OF THIS SITE ARE BASED ON AVAILABLE INFORMATION AT THE TIME OF DESIGN. DEVIATIONS MAY BE NECESSARY IN THE FIELD. ANY SUCH CHANGES OR CONFLICTS BETWEEN THIS PLAN AND FIELD CONDITIONS ARE TO BE REPORTED TO THE ARCHITECT/ENGINEER PRIOR TO STARTING CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LAYOUT VERIFICATION OF ALL SITE IMPROVEMENTS PRIOR TO CONSTRUCTION. CONTACT CITY OF WAUKEE FOR APPROVAL OF ANY CHANGES AND THAT ANY CHANGES COMPLETED WITHOUT APPROVAL ARE SUBJECT TO REMOVAL IN ORDER TO MEET THE CITY OF WAUKEE STANDARDS. J.CONTRACTOR TO LOAD AND TRANSPORT ALL MATERIALS CONSIDERED TO BE UNDESIRABLE TO BE INCORPORATED INTO THE PROJECT TO AN APPROVED OFF-SITE WASTE SITE. K.CONTRACTOR TO STRIP AND STOCKPILE TOPSOIL FROM ALL AREAS TO BE CUT OR FILLED. RESPREAD TO FINISH GRADES TO MEET SUDAS SPECIFICATIONS SECTION 2010 FOR TOPSOIL. L.ALL PROPOSED CONTOURS AND SPOT ELEVATIONS SHOWN ARE FINISHED GRADES AND/OR TOP OF PAVING SLAB (GUTTER), UNLESS OTHERWISE NOTED. M.THE CONTRACTOR IS RESPONSIBLE FOR CLEANING DIRT AND DEBRIS FROM NEIGHBORING STREETS, DRIVEWAYS, AND SIDEWALKS CAUSED BY CONSTRUCTION ACTIVITIES AT THE END OF EACH WORK DAY AND PRIOR TO A RAIN EVENT. N.THE ADJUSTMENT OF ANY EXISTING UTILITY APPURTENANCES TO FINAL GRADE IS CONSIDERED INCIDENTAL TO THE SITE WORK. O.THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING EROSION AND SEDIMENT CONTROL MEASURES AS NECESSARY. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR MAINTAINING ANY EXISTING EROSION CONTROL MEASURES ON SITE AT THE TIME OF CONSTRUCTION. GRADING AND SOIL EROSION CONTROL CODE REQUIREMENTS SHALL BE MET BY CONTRACTOR. A COSESCO PERMIT IS REQUIRED FOR THIS PROJECT. P.CONTRACTOR TO COORDINATE NATURAL GAS, ELECTRICAL, TELEPHONE AND ANY OTHER FRANCHISE UTILITY SERVICES WITH UTILITY SERVICE PROVIDER, CITY OF WAUKEE, AND THE OWNER PRIOR TO CONSTRUCTION. Q.IF STORM SEWER CROSSES ABOVE WATER MAIN OR CROSSES LESS THAN 18" BELOW A WATER MAIN THEN STORM SEWER SHALL BE CONSTRUCTED OF REINFORCED CONCRETE WITH A FLEXIBLE O-RING GASKET RATED AT 13 PSI OR GREATER. O-RING GASKET JOINTS SHALL BE INSTALLED ON EACH SIDE OF THE CROSSING UNTIL THE NORMAL DISTANCE FROM THE WATER MAIN TO THE STORM SEWER IS AT LEAST TEN FEET. R.A PRE-CONSTRUCTION MEETING WITH THE CITY OF WAUKEE WILL BE REQUIRED A MINIMUM OF ONE WEEK PRIOR TO CONSTRUCTION ACTIVITIES BEGINNING. S.ALL STAKING SHALL BE DONE UNDER THE DIRECTION OF A LICENSED ENGINEER OR LAND SURVEYOR INCLUDING PEDESTRIAN FACILITIES. T.ANY CHANGES PROPOSED TO THE DRAWINGS DURING CONSTRUCTION SHALL BE APPROVED IN WRITING BY THE CITY OF WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT PRIOR TO CONSTRUCTION. U.THE CONTRACTOR IS RESPONSIBLE FOR ANY CHANGES MADE DURING CONSTRUCTION THAT HAVE NOT BEEN GRANTED APPROVAL IN WRITING BY THE CITY OF WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT. V.ALL SANITARY SEWER AND STORM SEWER SHALL BE CLEANED AND TELEVISED PRIOR TO PAVING. THE CITY OF WAUKEE SHALL WITNESS ALL CLEANING AND TELEVISING. COPIES OF THE REPORT AND VIDEO SHALL BE PROVIDED TO THE CITY OF WAUKEE. ALL SANITARY SEWER MANHOLES SHALL BE VACUUM TESTED. W.PLACE 3/4" EXPANSION JOINT BETWEEN ALL PCC PAVEMENT/SIDEWALKS AND BUILDINGS. PLACE 1/2" EXPANSION JOINT BETWEEN SIDEWALKS AND PCC PAVEMENT. THE PCC RAMP JOINT LOCATED AT THE BACK OF CURB AND ALL EXPANSION JOINTS SHALL BE SEALED. X.AS-BUILTS SHALL BE PROVIDED TO THE WAUKEE ENGINEERING DEPARTMENT INCLUDING ALL UTILITIES AND AS-BUILT GRADES FOR DRAINAGE SWALES, OVERFLOWS, ACCESSIBLE RAMPS AND DETENTION FACILITIES. THE CONTRACTOR SHALL PROVIDE INFORMATION TO THE DESIGN ENGINEER FOR INCLUSION ON THE RECORD AS-BUILT DRAWINGS. Y.ALL UTILITIES INCLUDING PRIVATE UTILITIES SHALL BE CONSTRUCTED TO THE 2020 CITY OF WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND ALL UTILITIES SHALL BE TESTED TO CITY STANDARDS. THE CITY SHALL WITNESS ALL TESTING. Z.CONSTRUCTION OPERATIONS SHALL PROTECT STORM SEWERS AND DRAINAGE WAYS FROM ALLOWING CONCRETE SLURRY FROM CONCRETE OPERATIONS TO DISCHARGE OFFSITE. AA. CONTRACTOR SHALL COORDINATE ALL TIE-IN TO UTILITIES WITH THE CITY OF WAUKEE ENGINEERING DEPARTMENT AND CITY OF WAUKEE ENGINEERING DEPARTMENT SHALL WITNESS ALL TIE-INS. BB. ALL FIRE HYDRANTS WILL BE REQUIRED TO HAVE 5-INCH STORZ FITTINGS. CC. CONTRACTOR IS TO PROVIDE SHOP DRAWING SUBMITTALS OF CONSTRUCTION MATERIALS PRIOR TO CONSTRUCTION. DD. PRIOR TO ANY LANE CLOSURE THE CONTRACTOR IS RESPONSIBLE FOR HAVING A DIGITAL MESSAGE BOARD NOTIFYING DRIVERS OF LANE CLOSURES AT LEAST ONE WEEK PRIOR TO ANY CLOSURE. CONTRACTOR IS TO COORDINATE ANY LANE/ROAD CLOSURES WITH THE CITY OF WAUKEE. EE. APPROVED FIRE APPARATUS ACCESS ROADS SHALL BE PROVIDED FOR EVERY FACILITY, BUILDING, OR PORTION OF A BUILDING AS SOON AS CONSTRUCTION COMMENCES. THE FIRE APPARATUS ACCESS ROAD SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 503.2 AND THIS SECTION SHALL EXTEND TO WITHIN 100 FEET OF ALL PORTIONS OF THE EXTERIOR WALLS OF THE FIRST STORY OF THE BUILDING AS MEASURED BY AN APPROVED ROUTE AROUND THE EXTERIOR OF THE BUILDING OR FACILITY. FF. ALL SIGNAGE REQUIRES A SEPARATE PERMIT FROM THE CITY OF WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT. UTILITY QUALITY SERVICE LEVELS QUALITY LEVELS OF UTILITIES ARE SHOWN IN THE PARENTHESES WITH THE UTILITY TYPE AND WHEN APPLICABLE, SIZE. THE QUALITY LEVELS ARE BASED ON THE CI / ASCE 38-02 STANDARD. QUALITY LEVEL (D) INFORMATION IS DERIVED FROM EXISTING UTILITY RECORDS OR ORAL RECOLLECTIONS. QUALITY LEVEL (C) INFORMATION IS OBTAINED BY SURVEYING AND PLOTTING VISIBLE ABOVE-GROUND UTILITY FEATURES AND USING PROFESSIONAL JUDGMENT IN CORRELATING THIS INFORMATION WITH QUALITY D INFORMATION. QUALITY LEVEL (B) INFORMATION IS OBTAINED THROUGH THE APPLICATION OF APPROPRIATE SURFACE GEOPHYSICAL METHODS TO DETERMINE THE EXISTENCE AND APPROXIMATE HORIZONTAL POSITION OF SUBSURFACE UTILITIES. QUALITY LEVEL (A) IS HORIZONTAL AND VERTICAL POSITION OF UNDERGROUND UTILITIES OBTAINED BY ACTUAL EXPOSURE OR VERIFICATION OF PREVIOUSLY EXPOSED SUBSURFACE UTILITIES, AS WELL AS THE TYPE, SIZE, CONDITION, MATERIAL, AND OTHER CHARACTERISTICS. UTILITY WARNING THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR RECORDS OBTAINED. THE SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES OR SUBSURFACE FEATURES SHOWN COMPRISE ALL SUCH ITEMS IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UTILITIES OR SUBSURFACE FEATURES SHOWN ARE IN THE EXACT LOCATION INDICATED EXCEPT WHERE NOTED AS QUALITY LEVEL A. FEATURES EXISTING PROPOSED Spot Elevation Contour Elevation Fence (Barbed, Field, Hog) Fence (Chain Link) Fence (Wood) Fence (Silt) Tree Line Tree Stump Deciduous Tree \\ Shrub Coniferous Tree \\ Shrub Communication Overhead Communication Fiber Optic Underground Electric Overhead Electric Gas Main with Size High Pressure Gas Main with Size Water Main with Size Sanitary Sewer with Size Duct Bank Test Hole Location for SUE w/ID (*) Denotes the survey quality service level for utilities Sanitary Manhole Storm Sewer with Size Storm Manhole Single Storm Sewer Intake Double Storm Sewer Intake Fire Hydrant Fire Hydrant on Building Water Main Valve Water Service Valve Well Utility Pole Guy Anchor Utility Pole with Light Utility Pole with Transformer Street Light Yard Light Electric Box Electric Transformer Traffic Sign Communication Pedestal Communication Manhole Communication Handhole Fiber Optic Manhole Fiber Optic Handhole Gas Valve Gas Manhole Gas Apparatus Fence Post or Guard Post Underground Storage Tank Above Ground Storage Tank Sign Satellite Dish Mailbox Sprinkler Head Irrigation Control Valve LEGEND ○ 1 2 2 5 X 1225.25 ● X 1 2 2 5 1225.25 FEATURES FOUND SET Section Corner 1/2" Rebar, Cap # 11579 (Unless Otherwise Noted) ROW Marker ROW Rail Control Point Bench Mark Platted Distance P Measured Bearing & Distance M Recorded As R Deed Distance D Calculated Distance C Minimum Protection Elevation MPE Centerline Section Line 1/4 Section Line 1/4 1/4 Section Line Easement Line A.POLLUTION PREVENTION AND EROSION PROTECTION 1.CODE COMPLIANCE: THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL POTENTIAL POLLUTION AND SOIL EROSION CONTROL REQUIREMENTS OF THE IOWA CODE, THE IOWA DEPARTMENT OF NATURAL RESOURCES (IDNR) NPDES PERMIT, THE U.S. CLEAN WATER ACT AND ANY LOCAL ORDINANCES. THE CONTRACTOR SHALL TAKE ALL NECESSARY STEPS TO PROTECT AGAINST EROSION AND POLLUTION FROM THIS PROJECT SITE AND ALL OFF-SITE BORROW OR DEPOSIT AREAS DURING PERFORMANCE OR AS A RESULT OF PERFORMANCE. 2.DAMAGE CLAIMS: THE CONTRACTOR WILL HOLD THE OWNER AND ARCHITECT / ENGINEER HARMLESS FROM ANY AND ALL CLAIMS OF ANY TYPE WHATSOEVER RESULTING FROM DAMAGES TO ADJOINING PUBLIC OR PRIVATE PROPERTY, INCLUDING REASONABLE ATTORNEY FEES INCURRED TO OWNER. FURTHER, IF THE CONTRACTOR FAILS TO TAKE NECESSARY STEPS TO PROMPTLY REMOVE EARTH SEDIMENTATION OR DEBRIS WHICH COMES ONTO ADJOINING PUBLIC OR PRIVATE PROPERTY, THE OWNER MAY, BUT NEED NOT, REMOVE SUCH ITEMS AND DEDUCT THE COST THEREOF FROM AMOUNTS DUE TO THE CONTRACTOR. B.STORM WATER DISCHARGE PERMIT 1.THIS PROJECT REQUIRES COVERAGE UNDER THE NPDES GENERAL PERMIT NO. 2 FOR STORM WATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITIES FROM THE IDNR, AS REQUIRED BY THE ENVIRONMENTAL PROTECTION AGENCY (EPA). THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS ARE RESPONSIBLE FOR COMPLIANCE WITH AND FULFILLMENT OF ALL REQUIREMENTS OF THE NPDES GENERAL PERMIT NO. 2 AS SPECIFIED IN THE CONTRACT DOCUMENTS. 2.ALL DOCUMENTS RELATED TO THE STORM WATER DISCHARGE PERMIT, INCLUDING, BUT NOT LIMITED TO, THE NOTICE OF INTENT, PROOF OF PUBLICATIONS, DISCHARGE AUTHORIZATION LETTER, CURRENT SWPPP, SITE INSPECTION LOG, AND OTHER ITEMS, SHALL BE KEPT ON SITE AT ALL TIMES AND MUST BE PRESENTED TO ANY JURISDICTIONAL AGENCIES UPON REQUEST. FAILURE TO COMPLY WITH THE NPDES PERMIT REQUIREMENTS IS A VIOLATION OF THE CLEAN WATER ACT AND THE CODE OF IOWA. 3.A "NOTICE OF DISCONTINUATION" MUST BE FILED WITH THE IDNR UPON FINAL STABILIZATION OF THE DISTURBED SITE AND REMOVAL OF ALL TEMPORARY EROSION CONTROL MEASURES. ALL PLANS, INSPECTION REPORTS, AND OTHER DOCUMENTS MUST BE RETAINED FOR A PERIOD OF THREE YEARS AFTER PROJECT COMPLETION. THE CONTRACTOR SHALL RETAIN A RECORD COPY AND PROVIDE THE ORIGINAL DOCUMENTS TO THE OWNER UPON PROJECT ACCEPTANCE AND/OR SUBMITTAL OF THE NOTICE OF DISCONTINUATION. C.POLLUTION PREVENTION PLAN 1.THE STORM WATER POLLUTION PREVENTION PLAN (SWPPP) IS A SEPARATE DOCUMENT IN ADDITION TO THESE PLAN DRAWINGS. THE CONTRACTOR SHOULD REFER TO THE SWPPP FOR ADDITIONAL REQUIREMENTS AND MODIFICATIONS TO THE POLLUTION PREVENTION PLAN MADE DURING CONSTRUCTION. 2.THE SWPPP ILLUSTRATES GENERAL MEASURES AND BEST MANAGEMENT PRACTICES (BMP) FOR COMPLIANCE WITH THE PROJECT'S NPDES PERMIT COVERAGE. ALL BMP'S AND EROSION CONTROL MEASURES REQUIRED AS A RESULT OF CONSTRUCTION ACTIVITIES ARE THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY, NOTE AND IMPLEMENT. ADDITIONAL BMP'S FROM THOSE SHOWN ON THE PLAN MAY BE REQUIRED. 3.THE SWPPP AND SITE MAP SHOULD BE EXPEDITIOUSLY REVISED TO REFLECT CONSTRUCTION PROGRESS AND CHANGES AT THE PROJECT SITE. 4.THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL REQUIREMENTS OF THE GENERAL PERMIT AND SWPPP, INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING BMP'S UNLESS INFEASIBLE OR NOT APPLICABLE: a.UTILIZE OUTLET STRUCTURES THAT WITHDRAW WATER FROM THE SURFACE WHEN DISCHARGING FROM BASINS, PROVIDE AND MAINTAIN NATURAL BUFFERS AROUND SURFACE WATERS, DIRECT STORM WATER TO VEGETATED AREAS TO INCREASE SEDIMENT REMOVAL AND MAXIMIZE STORM WATER INFILTRATION, AND MINIMIZE SOIL COMPACTION. b.INSTALL PERIMETER AND FINAL SEDIMENT CONTROL MEASURES SUCH AS SILT BARRIERS, DITCH CHECKS, DIVERSION BERMS, OR SEDIMENTATION BASINS DOWNSTREAM OF SOIL DISTURBING ACTIVITIES PRIOR TO SITE CLEARING AND GRADING OPERATIONS. c.PRESERVE EXISTING VEGETATION IN AREAS NOT NEEDED FOR CONSTRUCTION AND LIMIT TO A MINIMUM THE TOTAL AREA DISTURBED BY CONSTRUCTION OPERATIONS AT ANY TIME. d.MAINTAIN ALL TEMPORARY AND PERMANENT EROSION CONTROL MEASURES IN WORKING ORDER, INCLUDING CLEANING, REPAIRING, REPLACEMENT, AND SEDIMENT REMOVAL THROUGHOUT THE PERMIT PERIOD. CLEAN OR REPLACE SILT CONTROL DEVICES WHEN THE MEASURES HAVE LOST 50% OF THEIR ORIGINAL CAPACITY. e.INSPECT THE PROJECT AREA AND CONTROL DEVICES (BY QUALIFIED PERSONNEL ASSIGNED BY THE CONTRACTOR) EVERY SEVEN CALENDAR DAYS. RECORD THE FINDINGS OF THESE INSPECTIONS AND ANY RESULTING ACTIONS IN THE SWPPP WITH A COPY SUBMITTED WEEKLY TO THE OWNER OR ENGINEER DURING CONSTRUCTION. REVISE THE SWPPP AND IMPLEMENT ANY RECOMMENDED MEASURES WITHIN 7 DAYS. f.PREVENT ACCUMULATION OF EARTH AND DEBRIS FROM CONSTRUCTION ACTIVITIES ON ADJOINING PUBLIC OR PRIVATE PROPERTIES, INCLUDING STREETS, DRIVEWAYS, SIDEWALKS, DRAINAGEWAYS, OR UNDERGROUND SEWERS. REMOVE ANY ACCUMULATION OF EARTH OR DEBRIS IMMEDIATELY AND TAKE REMEDIAL ACTIONS FOR FUTURE PREVENTION. g.INSTALL NECESSARY CONTROL MEASURES SUCH AS SILT BARRIERS, EROSION CONTROL MATS, MULCH, DITCH CHECKS OR RIPRAP AS SOON AS AREAS REACH THEIR FINAL GRADES AND AS CONSTRUCTION OPERATIONS PROGRESS TO ENSURE CONTINUOUS RUNOFF CONTROL. PROVIDE INLET AND OUTLET CONTROL MEASURES AS SOON AS STORM SEWERS ARE INSTALLED. h.RESPREAD A MINIMUM OF 8 INCHES OF TOPSOIL (INCLUDING TOPSOIL FOUND IN SOD) ON ALL DISTURBED AREAS, EXCEPT WHERE PAVEMENT, BUILDINGS OR OTHER IMPROVEMENTS ARE LOCATED. i.STABILIZE UNDEVELOPED, DISTURBED AREAS WITH MULCH, TEMPORARY SEED MIX, PERMANENT SEED MIX, SOD, OR PAVEMENT IMMEDIATELY AS SOON AS POSSIBLE UPON COMPLETION OR DELAY OF GRADING OPERATIONS. INITIATE STABILIZATION MEASURES IMMEDIATELY AFTER CONSTRUCTION ACTIVITY IS FINALLY COMPLETED OR TEMPORARILY CEASED ON ANY PORTION OF THE SITE AND WHICH WILL NOT RESUME FOR A PERIOD EXCEEDING 14 CALENDAR DAYS. j.COORDINATE LOCATIONS OF STAGING AREAS WITH THE OWNER AND RECORD IN THE SWPPP. UNLESS NOTED OTHERWISE, STAGING AREAS SHOULD CONTAIN THE FOLLOWING: JOB TRAILERS, FUELING / VEHICLE MAINTENANCE AREA, TEMPORARY SANITARY FACILITIES, MATERIALS STORAGE, AND CONCRETE WASHOUT FACILITY. CONTROL RUNOFF FROM STAGING AREAS WITH DIVERSION BERMS AND/OR SILT BARRIERS AND DIRECT TO A SEDIMENT BASIN OR OTHER CONTROL DEVICE WHERE POSSIBLE. CONCRETE WASHOUT MUST BE CONTAINED ONSITE. k.REMOVE ALL TEMPORARY EROSION CONTROL MEASURES AND SITE WASTE PRIOR TO FILING OF THE "NOTICE OF DISCONTINUATION". GENERAL USE GENERAL COMMERCIAL/OFFICE PROPERTY DESCRIPTION LOT 1, COVE AT KETTLESTONE PLAT 4 BEING AN OFFICIAL PLAT DALLAS COUNTY, IOWA. (1.73 AC) PROPERTY ADDRESS 1450 SE UNIVERSITY AVE WAUKEE, IA 50263 ZONING PLANNED UNIT DEVELOPMENT/ C-1 (COMMUNITY AND HIGHWAY SERVICE COMMERCIAL DISTRICT) RECORDED WITH BOOK 2016 PAGE 2362 OPEN SPACE SITE AREA: 75,242 SF (1.73 AC) IMPERVIOUS AREA:44,204 SF (58.75%) PERVIOUS AREA:31,038 SF (41.25%) BULK REGULATIONS FRONT YARD= ZERO (0') MINIMUM , NO MAXIMUM LOT AREA = NONE SIDE YARD = NONE EXCEPT FOR 10 FEET ADJACENT TO RESIDENTIAL REAR YARD = NONE EXCEPT FOR 25 FEET ADJACENT TO RESIDENTIAL MINIMUM OPEN SPACE = 15% PARKING REQUIREMENTS 8 SPACES PER 1000 SF OF FLEXIBLE SPACE: (9,970 SF / 1000 SF) x 8 SPACES = 80 SPACES REQUIRED 3 SPACES PER 1000 SF OF PROFESSIONAL/BUSINESS OFFICES RETAIL/ GENERAL COMMERCIAL: (1,920 SF / 1000 SF) x 3 SPACES = 6 SPACES REQUIRED 86 TOTAL SPACES REQUIRED 87 SPACES PROVIDED (INCLUDING 4 HANDICAP ACCESSIBLE SPACES ) BICYCLE PARKING:3% OF REQUIRED STALL 83 STALLS x 0.3 =3 BICYCLE PARKING SPOTS BUILDING DESCRIPTION 22' HEIGHT 11,550 SF COMMERCIAL/ OFFICE. CONTROL POINTS IOWA STATE PLANES SOUTH COORDINATE SYSTEM NAD83(2011)(EPOCH 2010.00) IARTN DERIVED - US SURVEY FEET CP1 N=582886.23 E=1545932.77 ELEV=1058.72 SET CUT "X" AT DOUBLE BACK OF CURB INTAKE, SOUTH SIDE OF SE BISHOP DRIVE, 40' WEST OF TOWNHOME ENTRANCE. CP2 N=582898.81 E=1545491.01 ELEV=1060.50 SET CUT "X" AT SOUTH BACK OF CURB INTAKE OF SE BISHOP DRIVE, 5' NORTH OF STREET LIGHT, 50' WEST OF SOUTH ENTRANCE. CP3 N=583247.92 E=1545528.02 ELEV=1058.62 SET CUT "X" AT SOUTH BACK OF CURB SE UNIVERSITY AVE, 5' NORTH OF STREET LIGHT, 150' EAST OF EMERALD DRIVE. CP4 N=583246.40 E=1545986.91 ELEV=1058.54 SET CUT "X" AT SOUTH BACK OF CURB SE UNIVERSITY AVE, 20' NORTH OF POWER POLE, 75' SOUTH OF HYDRANT. BENCHMARKS NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88 - GEOID12A) IARTN DERIVED - US SURVEY FEET BM1 ELEV=1061.03 BURY BOLT ON HYDRANT, IN FRONT OF UNIT #1356, SOUTH SIDE SE BISHOP DRIVE. BM2 ELEV=1062.50 BURY BOLT ON HYDRANT, IN FRONT OF UNIT #1296, SOUTH SIDE SE BISHOP DRIVE.UTILITY CONTACT INFORMATION UTILITY CONTACT FOR MAPPING INFORMATION SHOWN AS RECEIVED FROM THE IOWA ONE CALL DESIGN REQUEST SYSTEM, TICKET NUMBER 552003655. AUREON NETWORK SERVICES JEFF KLOCKO 515-830-0445 JEFF.KLOCKO@AUREON.COM CENTURYLINK TOM STURMER 720-578-8090 THOMAS.STURMER@CENTURYLINK.COM CONSOLIDATED COMMUNICATIONS JUSTIN GREV 507-386-3606 JUSTIN.GREV@CONSOLIDATED.COM INTERNET CONSULTING SERVICES, ADAM WOODARD 515-268-4045 LOCATES@ICS-LLC.NET MEDIACOM COMMUNICATIONS CORP PAUL MAY 515-246-2252 PMAY@MEDIACOMCC.COM MI-FIBER JACK JONES 515-897-9192 JACK@GRM.NET F01-FIBER OPTIC FO2-FIBER OPTIC C1-COMMUNICATIONS NO RESPONSE NO RESPONSE CLEAR NO RESPONSE E-ELECTRIC OE-OVERHEAD ELECTRIC NO RESPONSE FO3-FIBER OPTIC FO4-FIBER OPTIC W-WATER S-SANITARY SEWER G-GAS MIDAMERICAN ENERGY CRAIG RANFELD 515-252-6632 MECDSMDESIGNLOCATES@MIDAMERICAN.COM NEXGEN INTEGRATED COMMUNICATIO RYAN ROLWES 515-369-7131 RYAN@NEXGENCOM.COM UNITE PRIVATE NETWORKS, LLC JOE KILZER 816-425-3556 UPNGIS@UPNFIBER.COM WINDSTREAM COMMUNICATIONS LOCATE DESK 800-289-1901 LOCATE.DESK@WINDSTREAM.COM WAUKEE, CITY OF TIM ROYER 515-978-7920 TROYER@WAUKEE.ORG POLLUTION PREVENTION NOTES FIRE RISER ROOM PROPOSED BUILDING 11,890 SF T 1454 1458 1462 1466 1474 1478 1482 TRASH TRASH 10' Existing Public Utility Easement (Bk 2015, Pg 20833) 15' Existing Private Sanitary Sewer Easement (Bk 2022, Pg 9126) Existing 30' Private Access Easement (Bk 2022, Pg 9126) 20' Existing Private Storm Sewer Easement (Bk 2015, Pg 20839) Existing 30' Private Access Easement (Bk 2022, Pg 9126) 30' BUILDING SETBACK 1475 SE BISHOP DR LOT 2 COVE A T K E T T L E S T O N E P L A T 3 OWNER : S P L A S H E S P R E S S , L L C ZONING : C - 1 / P D - 1 75,242 SF 1.73 AC LOT 1 N0 ° 1 1 ' 2 0 " E 3 0 1 . 5 9 ' M N0 ° 1 0 ' 3 1 " E 3 0 1 . 7 0 ' P S89°48'38"E 253.72' M S89°48'30"E 253.77' P S0 ° 1 9 ' 4 1 " W 2 7 0 . 0 0 ' M N0 ° 1 9 ' 3 5 " E 2 7 0 . 0 0 ' P N89°59'54"W 114.03' S38 ° 2 4 ' 5 9 " W 1 0 6 . 7 2 ' C 7 SE UNIVERSITY AVE 60.00' HALF ROW 10' Private Water Easement 15' Private Storm Sewer Easement Existing Storm Sewer Easement (Bk 2006, Pg 13760) 100 S E B I S H O P D R I V E C O N C R E T E CONCRETE CONCRETE CONCRETE CONCRETE CONCRETE CO N C R E T E 1056.26' INTAKE 1050.81' INV N 15" RCP 1057.10' RIM 1050.65' INV S 30" RCP 1050.60' INV E 30" RCP 1058.88' INTAKE 1056.98' INV NW 6" CPP 1059.09' RIM 1052.04' INV N 24" RCP 1052.09' INV SW 24" RCP 1059.09' RIM 1051.49' INV NE 24" RCP 1051.49' INV SW 24" RCP 1052.09' INV NW 6" CPP 1056.59' RIM 1053.34' INV SE 6" CPP 1053.44' INV NW 6" CPP 1059.50' RIM 1041.25' INV S 8" PVC 1041.25' INV SE 8" PVC 1041.10' INV W 8" PVC 1055.15' RIM 1051.05' INV S 30" RCP 1050.80' INV N 30" RCP 1050.90' INV SW 24" RCP 1057.89' RIM 1051.34' INV W 6" CPP 1051.29' INV S 24" RCP 1050.99' INV NE 24" RCP 1055.10' INV NW 12" CPP 1053.57' INV NW 6" CPP VACCUUM VACCUUM 1051.04' INV N 30" RCP 3A 3A 3A 3A 3A3A 3A 3C 3C 3C 3C 3C 1A 1A 1A 3E 3E 3E 3E 4A 4A 4B 4C 4C 3F 5A 3F 4A 4A 3D 3D 3D 3D 3D 3D 3D 3D 1B 1B 1B 1B 3B 3B 3B 3B 6A 6C 151.2' 80 . 6 ' 18 . 0 ' 25 . 0 ' 18 . 0 ' 6. 0 ' 10 . 0 ' 6. 0 ' 25 . 0 ' 18 . 0 ' 25.0'18.0'6.0'1.9' 1.9'6.0'18.0' R1 5 . 0 ' R 5 . 0 ' R 5 . 0 ' R 4 . 0 ' R5. 0 ' R 1 5 . 0 ' R5.0 ' R 5 . 0 ' R1 5 . 0 ' R 1 5 . 0 ' R5.0 ' R 5 . 0 ' R15 . 0 ' R5 . 0 ' R 5 . 0 ' R5 . 0 ' R 5 . 0 ' R15.0 ' R1 5 . 0 ' R5. 0 ' R5. 0 ' R5.0' 2C 2D 3C 2B 2B 2A 2A 2A 2A2A2A 9. 0 ' TY P TYP TYP TYP TYP 9.0' TYP 13 . 3 ' 9. 0 ' TY P 9.0' TYP 3C 3C3C 3C 1A 1A 1A 31.0' B/B 6B 5.0 ' 1A 3B R1 5 . 0 ' 3C 18 . 0 ' 3E 5.0' 7B7B 7B 7B 7B 7B 5A 5. 0 ' 2A 6D R5 . 0 ' 3H3H 3I 3C 3C3C 3F 1A 1A 5.0' TYP 5.0' TYP 10' PUE 2B 2B 3H 3H 3F 4B 4B 2A3B 7. 3 ' V: \ P r o j e c t s \ 2 0 2 1 \ 1 2 1 . 1 2 2 2 . 0 1 A \ C A D D \ S P _ 1 2 1 1 2 2 2 A _ D I M . d w g LO G A N M Y E R S , DI M E N S I O N P L A N , 20 2 3 / 0 2 / 2 8 , 3: 2 8 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 20 BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m KM M LJ M KS 11 - 0 7 - 2 2 20 ' 12 1 . 1 2 2 2 . 0 1 A C2 0 0 121.1222.01A C200 CO V E A T K E T T L E S T O N E P L A T 4 , L O T 1 DI M E N S I O N P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 01 - 1 0 - 2 3 01 - 3 1 - 2 3 02 - 1 4 - 2 3 02 - 2 8 - 2 3 KS LJ M LJ M LJ M 3456 TT N - R R W - S S DIMENSION PLAN CONSTRUCTION NOTES 1.EXISTING FEATURES, PROTECT THE FOLLOWING: A.PAVEMENTS TO REMAIN. B.PROTECT EXISTING UTILITIES, ANY DAMAGE TO THE EXISTING UTILITIES THAT ARE NOT SCHEDULED FOR MODIFICATION OR DEMOLITION SHALL BE REMEDIED AT THE CONTRACTORS EXPENSE WITH WORK BEING PREFORMED TO THE UTILITY OWNER'S SPECIFICATION. 2.DEMOLITION, REMOVE THE FOLLOWING: A.REMOVE 2 FOOT CURB & GUTTER SECTION. SAWCUT FULL DEPTH AT REMOVAL LIMITS. B.SAWCUT FULL DEPTH AT REMOVAL LIMITS, REMOVE AND DISPOSE OF EXISTING PCC. C.REMOVE EXISTING TREES. D.REMOVE AND DISPOSE OF EXISTING STORM SEWER. 3.PAVEMENTS, PROVIDE THE FOLLOWING: A.PCC PARKING, 6" DEPTH PAVEMENT ON 12" DEPTH PREPARED SUBGRADE COMPACTED TO 95% STANDARD PROCTOR DENSITY. B.PCC DRIVES, 7" DEPTH PAVEMENT ON 12" DEPTH PREPARED SUBGRADE COMPACTED TO 95% STANDARD PROCTOR DENSITY. C.PCC SIDEWALKS, 4" DEPTH PAVEMENT. D.6" STANDARD CURB. SEE DETAIL THIS SHEET. E.PCC INTEGRAL SIDEWALK AND CURB. SEE DETAIL THIS SHEET. F.PEDESTRIAN RAMP WITH A MAXIMUM SLOPE OF 8.33%. PROVIDE DETECTABLE WARNING SYSTEM AT RAMPS WHERE PEDESTRIAN TRAFFIC MEETS VEHICULAR TRAFFIC. G.TAPER TO NO CURB IN 3 FEET. H.NO CURB. I.4" PCC PATIO. 4.PAVEMENT MARKINGS, PROVIDE THE FOLLOWING: A.4" WIDE PAINTED PARKING STALL LINES. B.PAINTED STATE OF IOWA APPROVED ACCESSIBLE PARKING SYMBOL. C.ACCESSIBLE AISLE. 45° STRIPING AT 3' ON CENTER SPACING WHERE SHOWN. 5.SIGNS, PROVIDE THE FOLLOWING: A.PROVIDE VAN ACCESSIBLE PARKING SIGNAGE AS PER ADAAG REQUIREMENTS. ATTACH SIGN(S) TO WALL AS NECESSARY 6.SITE AMENITIES, PROVIDE THE FOLLOWING: A.TRASH ENCLOSURES. SEE ARCHITECTURAL PLANS FOR DETAILS. B.BIKE RACK. C.TRANSFORMER. D.SCREENING WALL. SEE ARCHITECTURAL PLANS FOR DETAILS. 7.SITE LIGHTING, PROVIDE THE FOLLOWING: A.CONTRACTOR TO COORDINATE WITH THE UTILITY OWNER AND PROPERTY OWNER ALL ASPECTS OF ELECTRICAL SERVICE. B.SITE LIGHTING SHOWN IS FOR ILLUSTRATION PURPOSES ONLY. CONTRACTOR TO COORDINATE WITH THE OWNER ALL ASPECTS SITE LIGHTING PRIOR TO CONSTRUCTION. 8.THE CITY OF WAUKEE IS NOT RESPONSIBLE FOR PAVEMENT REPLACEMENT WITHIN EXISTING SANITARY SEWER EASEMENT IF PAVEMENT NEEDS TO BE REMOVED FOR MAINTENANCE OF THE SANITARY SEWER. PAVEMENT LEGEND 4" PCC SIDEWALK 6" PCC PAVEMENT 7" PCC PAVEMENT FORM GRADE ELEV. 1 C200 6-INCH STANDARD CURB NO SCALE 6" 2 C200 INTEGRAL SIDEWALK AND CURB DETAIL NO SCALE ADJACENT PAVEMENT SIDEWALK 4" M I N 3 C200 TYPICAL PAVEMENT CROSS SECTIONS NO SCALE PCC PAVEMENT SECTION PCC SIDEWALK SECTION SLOPE AS PER PLANS 2% MAX 4 1 2" 7 1 2" 6" 12"18" R3" R3" 1" RADIUS SEALED 'E' JOINT PCC PAVEMENT, SEE PLANS FOR THICKNESS & LOCATIONS 12" DEPTH PREPARED SUBGRADE 2 - 6" LIFTS UNLESS NOTED OTHERWISE SIDEWALK PAVEMENT, SEE PLANS FOR THICKNESS & LOCATIONS 6" DEPTH PREPARED SUBGRADE 4 C200 3-INCH ROLLED CURB NO SCALE 2 1 2" 10 1 2" 3" 7" FINISHED GRADE OR SIDEWALK (SEE PLAN) 3" DROP CURB 2"R 1"R CURVE TABLE CURVE NO. C7 Δ 18°09'58" RADIUS 285.00' ARC LENGTH 90.36' TANGENT 45.56' CHORD BEARING/LENGTH N54°01'20"W 89.98' FIRE RISER ROOM PROPOSED BUILDING 11,890 SF T 1454 1458 1462 1466 1474 1478 1482 TRASH TRASH 10' Existing Public Utility Easement (Bk 2015, Pg 20833) 10' Existing Public Utility Easement (Bk 2015, Pg 20833) 10' Existing Public Utility Easement (Bk 2019, Pg 21475) 20' Existing Storm Sewer Easement (Bk 2015, Pg 20833) Existing Public Sidewalk Easement (Bk 2019, Pg 21474) 10' Existing Sanitary Sewer Easement (Bk 2015, Pg 20833) 15' Existing Private Sanitary Sewer Easement (Bk 2022, Pg 9126) Existing 30' Private Access Easement (Bk 2022, Pg 9126) 20' Existing Private Storm Sewer Easement (Bk 2015, Pg 20839) Existing 30' Private Access Easement (Bk 2022, Pg 9126) 25' B U I L D I N G S E T B A C K 30' BUILDING SETBACK 1475 SE BISHOP DR 10' Existing Gas Easement (Bk 2022, Pg 9125) LOT 2 COVE A T K E T T L E S T O N E P L A T 3 OWNER : S P L A S H E S P R E S S , L L C ZONING : C - 1 / P D - 1 75,242 SF 1.73 AC LOT 1 N0 ° 1 1 ' 2 0 " E 3 0 1 . 5 9 ' M N0 ° 1 0 ' 3 1 " E 3 0 1 . 7 0 ' P S89°48'38"E 253.72' M S89°48'30"E 253.77' P S0 ° 1 9 ' 4 1 " W 2 7 0 . 0 0 ' M N0 ° 1 9 ' 3 5 " E 2 7 0 . 0 0 ' P N89°59'54"W 114.03' S38 ° 2 4 ' 5 9 " W 1 0 6 . 7 2 ' C 7 Existing Feeder Main Easement (Bk 2005, Pg 1875) Existing Feeder Main Easement (Bk 2005, Pg 1875) SE UNIVERSITY AVE 60.00' HALF ROW 10' Private Water Easement 15' Private Storm Sewer Easement Existing Storm Sewer Easement (Bk 2006, Pg 13760) 100 UNIVERSITY AVENUE CONCRETE S E B I S H O P D R I V E C O N C R E T E CONCRETE CONCRETE CONCRETE CONCRETE CONCRETE CO N C R E T E 1059.77' RIM 1052.97' INV N 18" RCP 1053.17' INV SW 18" RCP 1056.26' INTAKE 1050.81' INV N 15" RCP 1057.10' RIM 1050.65' INV S 30" RCP 1050.60' INV E 30" RCP 1058.88' INTAKE 1056.98' INV NW 6" CPP 1059.09' RIM 1052.04' INV N 24" RCP 1052.09' INV SW 24" RCP 1059.09' RIM 1051.49' INV NE 24" RCP 1051.49' INV SW 24" RCP 1052.09' INV NW 6" CPP 1058.23' INTAKE 1052.53' INV S 24" RCP 1058.89' RIM 1052.36' INV NE 24" RCP 1058.24' INTAKE 1052.64' INV N 24" RCP 1058.99' RIM 1052.89' INV N 24" RCP 1056.59' RIM 1053.34' INV SE 6" CPP 1053.44' INV NW 6" CPP 1059.50' RIM 1041.25' INV S 8" PVC 1041.25' INV SE 8" PVC 1041.10' INV W 8" PVC 1055.15' RIM 1051.05' INV S 30" RCP 1050.80' INV N 30" RCP 1050.90' INV SW 24" RCP 1057.89' RIM 1051.34' INV W 6" CPP 1051.29' INV S 24" RCP 1050.99' INV NE 24" RCP 1055.10' INV NW 12" CPP 1053.57' INV NW 6" CPP 1056.61' RIM 1042.61' INV S 8" PVC 1042.51' INV NW 8" PVC VACCUUM VACCUUM 1051.04' INV N 30" RCP H YD H YD HYD EX 12" RCP FESFL=1041.39 EX SAN MH RIM=1059.86 T 15 0 ' H Y D R A N T C O V E R A G E 1A 1A 1A 1A 2B 2C 5 2D INV: 1047.55 INV: 1048.63 3C 3F 3G 3B 3A 3J 3H 3I 5 1A 5 3D 1A 1A 3E ST BP: 1053.35 WAT TP: 1051.61 ST BP: 1053.45 SAN TP: 1048.83 5 WAT BP: 1052.81 SAN TP: 1049.11 6" ADS N-12 PERF. UNDERDRAIN (SEE STORMTECH DETAILS ON C600) 5ST BP: 1050.85 SAN TP: 1048.83 WAT BP: 1051.76 SAN TP: 1047.90 60 LF OF SANITARY INV: 1053.96 2C INV: 1048.44 2C 2C INV: 1049.29 2A 2A INV: 1049.07 2E 2B 5ST TP: 1048.82 WAT BP: 1051.39 SAN TP: 1048.56 ST BP: 1053.46 5 SC-740 CHAMBER (SEE STORMTECH DETAILS ON C600) EXISTING 6" SANITARY LINE 4 22 LF OF SANITARY 89 LF OF SANITARY 18 LF OF SANITARY V: \ P r o j e c t s \ 2 0 2 1 \ 1 2 1 . 1 2 2 2 . 0 1 A \ C A D D \ S P _ 1 2 1 1 2 2 2 A _ U T I L . d w g LO G A N M Y E R S , UT I L I T Y P L A N , 20 2 3 / 0 2 / 2 8 , 3: 2 8 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 30 BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m KM M LJ M KS 11 - 0 7 - 2 2 30 ' 12 1 . 1 2 2 2 . 0 1 A C3 0 0 121.1222.01A C300 CO V E A T K E T T L E S T O N E P L A T 4 , L O T 1 UT I L I T Y P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 01 - 1 0 - 2 3 01 - 3 1 - 2 3 02 - 1 4 - 2 3 02 - 2 8 - 2 3 KS LJ M LJ M LJ M 3456 TT N - R R W - S S UTILTIY PLAN CONSTRUCTION NOTES 1. EXISTING FEATURES, PROTECT THE FOLLOWING: A. PROTECT EXISTING UTILITES, ANY DAMAGE TO THE EXISTING UTILITIES THAT ARE NOT SCHEDULED FOR MODIFICATION OR DEMOLITION SHALL BE REMEDIED AT THE CONTRACTORS EXPENSE WITH WORK BEING PERFORMED TO THE UTILITY OWNER'S SPECIFICATION. 2. SANITARY SEWER SERVICES; PROVIDE THE FOLLOWING: A. 6" SANITARY SEWER SERVICE LINE @ MINIMUM 1.0% B. CONNECT TO BUILDING SANITARY SERVICE. VERIFY LOCATION AND ELEVATION WITH MECHANICAL PLANS PRIOR TO CONSTRUCTION. C. SANITARY SEWER CLEANOUT. D. CONNECT TO EXISTING 8" SANITARY SEWER. CONTRACTOR TO VERIFY LOCATION AND ELEVATION PRIOR TO CONSTRUCTION. USE 1:1 RISER AS NECESSARY. E. WRA APPROVED GREASE INTERCEPTOR. SEE MECHANICAL PLANS FOR DETAILED DRAWINGS OF GREASE INTERCEPTOR. COORDINATE EXACT SIZE/ELEVATIONS WITH MECHANICAL PLANS PRIOR TO CONSTRUCTION. 3. WATER SERVICES, PROVIDE THE FOLLOWING: A. 8" WATER SERVICE LINE. B. 4" DOMESTIC WATER SERVICE C. BUILDING WATER SERVICE CONNECTION. VERIFY LOCATION AND DEPTH WITH MECHANICAL PLANS PRIOR TO CONSTRUCTION. D. CONNECT TO EXISTING WATER MAIN WITH 8" X 8" TAPPING SLEEVE AND VALVE. CONTRACTOR TO VERIFY LOCATION AND DEPTH PRIOR TO CONSTRUCTION. E. REMOTE FIRE DEPARTMENT CONNECTION. COORDINATE WITH MECHANICAL PLANS. F. 6" VALVE G. 4" VALVE H. 6" FIRE SERVICE LINE I. HYDRANT ASSEMBLY. J. 8" X 8" TEE WITH REDUCER 4. COORDINATE NATURAL GAS AND ELECTRICAL SERVICES AND METER LOCATION WITH UTILITY SERVICE PROVIDER PRIOR TO CONSTRUCTION. SEE ARCHITECTURAL AND MECHANICAL PLANS FOR INTERIOR UTILITY ROUTING, METERS, DESIGN INFORMATION AND COORDINATE UTILITY CONNECTIONS ACCORDINGLY. 5. CRITICAL CROSSING. CONTRACTOR TO VERIFY ALL CROSSINGS AND PROVIDE 18" MINIMUM SEPARATION. GENERAL CONSTRUCTION NOTES A. NOTIFY THE CITY OF WAUKEE AT LEAST 48 HRS PRIOR TO CONNECTING TO ANY PUBLIC UTILITY. B. ALL UTILITIES SHALL BE TESTED TO THE CITY OF WAUKEE STANDARD SPECIFICATION FOR PUBLIC IMPROVEMENTS AND ANY TESTING OR TIE-INS SHALL BE WITNESSED BY THE CITY OF WAUKEE ENGINEERING DEPARTMENT. C. ALL SANITARY SEWER AND STORM SEWER SHALL BE CLEANED AND TELEVISED PRIOR TO PAVING. THE CITY OF WAUKEE SHALL WITNESS ALL CLEANING AND TELEVISING. COPIES OF THE REPORT AND VIDEO SHALL BE PROVIDED TO THE CITY OF WAUKEE. ALL SANITARY SEWER MANHOLES SHALL BE VACUUM TESTED. D. ALL WATERMAIN SHALL BE PRESSURE AND BACTERIA TESTED AND DECHLORINATED. EXISTING 8" WATER MAIN FIRE RISER ROOM PROPOSED BUILDING 11,890 SF T 1454 1458 1462 1466 1474 1478 1482 TRASH TRASH 100 UNIVERSITY AVENUE CONCRETE S E B I S H O P D R I V E C O N C R E T E CONCRETE CONCRETE CONCRETE CONCRETE CONCRETE CO N C R E T E 1059.77' RIM 1052.97' INV N 18" RCP 1053.17' INV SW 18" RCP 1056.26' INTAKE 1050.81' INV N 15" RCP 1057.10' RIM 1050.65' INV S 30" RCP 1050.60' INV E 30" RCP 1058.88' INTAKE 1056.98' INV NW 6" CPP 1059.09' RIM 1052.04' INV N 24" RCP 1052.09' INV SW 24" RCP 1059.09' RIM 1051.49' INV NE 24" RCP 1051.49' INV SW 24" RCP 1052.09' INV NW 6" CPP 1058.23' INTAKE 1052.53' INV S 24" RCP 1058.89' RIM 1052.36' INV NE 24" RCP 1058.24' INTAKE 1052.64' INV N 24" RCP 1058.99' RIM 1052.89' INV N 24" RCP 1056.59' RIM 1053.34' INV SE 6" CPP 1053.44' INV NW 6" CPP 1059.50' RIM 1041.25' INV S 8" PVC 1041.25' INV SE 8" PVC 1041.10' INV W 8" PVC 1055.15' RIM 1051.05' INV S 30" RCP 1050.80' INV N 30" RCP 1050.90' INV SW 24" RCP 1057.89' RIM 1051.34' INV W 6" CPP 1051.29' INV S 24" RCP 1050.99' INV NE 24" RCP 1055.10' INV NW 12" CPP 1053.57' INV NW 6" CPP 1056.61' RIM 1042.61' INV S 8" PVC 1042.51' INV NW 8" PVC VACCUUM VACCUUM 1051.04' INV N 30" RCP H YD H YD HYD EX 12" RCP FESFL=1041.39 EX SAN MH RIM=1059.86 T 10' Existing Public Utility Easement (Bk 2015, Pg 20833) 10' Existing Public Utility Easement (Bk 2015, Pg 20833) 10' Existing Public Utility Easement (Bk 2019, Pg 21475) 20' Existing Storm Sewer Easement (Bk 2015, Pg 20833) Existing Public Sidewalk Easement (Bk 2019, Pg 21474) 10' Existing Sanitary Sewer Easement (Bk 2015, Pg 20833) 15' Existing Private Sanitary Sewer Easement (Bk 2022, Pg 9126) Existing 30' Private Access Easement (Bk 2022, Pg 9126) 20' Existing Private Storm Sewer Easement (Bk 2015, Pg 20839) Existing 30' Private Access Easement (Bk 2022, Pg 9126) 25' B U I L D I N G S E T B A C K 30' BUILDING SETBACK 1475 SE BISHOP DR 10' Existing Gas Easement (Bk 2022, Pg 9125) LOT 2 COVE A T K E T T L E S T O N E P L A T 3 OWNER : S P L A S H E S P R E S S , L L C ZONING : C - 1 / P D - 1 75,242 SF 1.73 AC LOT 1 N0 ° 1 1 ' 2 0 " E 3 0 1 . 5 9 ' M N0 ° 1 0 ' 3 1 " E 3 0 1 . 7 0 ' P S89°48'38"E 253.72' M S89°48'30"E 253.77' P S0 ° 1 9 ' 4 1 " W 2 7 0 . 0 0 ' M N0 ° 1 9 ' 3 5 " E 2 7 0 . 0 0 ' P N89°59'54"W 114.03' S38 ° 2 4 ' 5 9 " W 1 0 6 . 7 2 ' C 7 Existing Feeder Main Easement (Bk 2005, Pg 1875) Existing Feeder Main Easement (Bk 2005, Pg 1875) SE UNIVERSITY AVE 60.00' HALF ROW 10' Private Water Easement 15' Private Storm Sewer Easement Existing Storm Sewer Easement (Bk 2006, Pg 13760) ST-7, INTAKE, SW-505 T/C: 1056.17 FG: 1055.67 INV: 1052.00 (OUT W) ST-7A, 30" NYLOPLAST BASIN W/ SOLID LID PROVIDE 24" OF SUMP SUMP=1049.30 RIM: 1055.81 INV: 1051.61 (IN E) INV: 1051.51 (OUT W) P-6B, 8 LF OF 12" RCP @ 0.66% P-6, 48 LF OF 12" RCP @ 1.53% ST-5A, 30" NYLOPLAST BASIN W/ SOLID LID PROVIDE 24" OF SUMP SUMP=1049.30 RIM: 1056.69 INV: 1051.61 (IN W) INV: 1051.51 (OUT E) ST-6, INTAKE, SW-501 T/C: 1056.76 FG: 1056.26 INV: 1052.45 (IN SW) INV: 1052.35 (OUT E) ST-2, 10" NYLOPLAST BASIN W/ STANDARD GRATE RIM: 1057.60 INV: 1054.08 (OUT SE) P-2, 48 LF OF 10" HDPE @ 1.65% ST-3, INTAKE, SW-511 RIM: 1056.61 INV: 1054.29 (IN N) (VERIFY) INV: 1053.29 (IN E) INV: 1053.29 (IN NW) INV: 1053.19 (OUT S) P-1, 92 LF OF 12" RCP @ 0.50% P-3, 12 LF OF 15" RCP @ 0.50% ST-1, INTAKE, SW-511 RIM: 1056.61 INV: 1053.75 (OUT W) ST-3B, 15'' FES INV: 1052.90 ST-4D, SW-513 (4' X 4') OPEN ON ONE SIDE (NW) (3' WIDE X 9" TALL) (SEE DETAIL ON SHEET C600) RIM: 1057.14 THROAT: 1056.85 INV: 1051.20 (IN NW) INV: 1051.20 (IN NE) INV: 1051.10 (OUT SE) P-4, 12 LF OF 12" RCP @ 28.85% ST-4, 12'' RCP APRON W/ FOOTING AND TRASH GUARD. INSTALL 3" ORIFICE INV: 1054.80 (SEE DETAIL ON C600) ST-4E, 12'' RCP FES W/ FOOTING INV: 1050.87 P-4D, 32 LF OF 12" RCP @ 0.73% P-7, 8 LF OF 12" RCP @ 4.69% ST BP: 1053.35 WAT TP: 1051.61 ST BP: 1053.45 SAN TP: 1048.83 6" ADS N-12 PERF. UNDERDRAIN (SEE STORMTECH DETAILS ON C600) SOUTH BASIN SUBDRAIN (SEE DETAIL 3/C600) ST BP: 1050.85 SAN TP: 1048.83 ST-6B, 30" NYLOPLAST BASIN W/ SOLID LID AND 30 DEGREE V-WEIR WITH 3" ORIFICE (SEE DETAIL) RIM: 1057.00 INV: 1050.95 (OUT NW) P-4B, 25 LF OF 6" N12 HDPE @ 0.10% P-4A, 22 LF OF 6" N12 HDPE @ 0.10%ST-4A, 8" NYLOPLAST BASIN W/ SOLID GRATE RIM: 1052.90 INV: 1051.26 (OUT SW)ST-4B, 8" NYLOPLAST BASIN W/ SOLID GRATE RIM: 1052.90 INV: 1051.24 (IN NE) INV: 1051.24 (OUT SE) ST-4C, 8" NYLOPLAST BASIN W/ SOLID LID RIM: 1057.11 INV: 1051.21 (IN NW) INV: 1051.21 (OUT SW) P-3A, 26 LF OF 15" RCP @ 0.50% ST-3A, MANHOLE, SW-401 INSTALL DOWNSTREAM DEFENDER. SEE DETAILS. RIM: 1056.74 INV: 1053.13 (IN N) INV: 1053.03 (OUT S) INV: 1054.21 INV: 1053.69 CONNECT TO STRUCTURE @ 1054.08 CONNECT TO PIPE @ 1054.27 (VERIFY)P-9, 56 LF OF 8" PVC STORM SERVICE @ 0.60% P-11, 58 LF OF 8" PVC STORM SERVICE @ 0.80% P-13, 61 LF OF 8" PVC STORM SERVICE @ 0.50% INV: 1054.03 INV: 1054.06 (EXISTING 24") (EXISTING 30") ST-5, INTAKE, SW-501 T/C: 1057.20 FG: 1056.70 INV: 1053.59 (OUT NE) P-5, 50 LF OF 12" RCP @ 2.29% S-32, 60" MANHOLE, SW-401 REMOVE EXISTING STORM SEWER PIPES AND FOOTING INSTALL NEW STRUCTURE AND CONNECT TO EXISTING PIPES. CONTRACTOR TO MAINTAIN POSITIVE DRAINAGE DURING ALL TIMES DURING CONSTRUCTION. RIM: 1057.85 INV: 1050.90 (IN SW) INV: 1050.90 (IN SE) INV: 1050.80 (OUT N) ST TP: 1048.82 WAT BP: 1051.39 SAN TP: 1048.56 ST BP: 1053.46 SC-740 CHAMBER (SEE STORMTECH DETAILS ON C600) EXISTING 6" SANITARY LINE 1A 1A 1A 22 3 1A 1A 1A P-8, 25 LF OF 8" PVC STORM SERVICE 0.50% 2 3 CONNECT TO PIPE @ 1054.46 (VERIFY) CONNECT TO INTAKE @ 1053.75 3 3 2 2 (PROPOSED 12") 3 P-10, 56 LF OF 8" PVC STORM SERVICE @ 0.60% INV: 1054.56 3 INV: 1054.92 P-12, 61 LF OF 8" PVC STORM SERVICE @ 0.50% V: \ P r o j e c t s \ 2 0 2 1 \ 1 2 1 . 1 2 2 2 . 0 1 A \ C A D D \ S P _ 1 2 1 1 2 2 2 A _ S T R M . d w g LO G A N M Y E R S , ST O R M S E W E R P L A N , 20 2 3 / 0 2 / 2 8 , 3: 2 8 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 30 BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m KM M LJ M KS 11 - 0 7 - 2 2 30 ' 12 1 . 1 2 2 2 . 0 1 A C3 0 1 121.1222.01A C301 CO V E A T K E T T L E S T O N E P L A T 4 , L O T 1 ST O R M S E W E R P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 01 - 1 0 - 2 3 01 - 3 1 - 2 3 02 - 1 4 - 2 3 02 - 2 8 - 2 3 KS LJ M LJ M LJ M 3456 TT N - R R W - S S UTILTIY PLAN CONSTRUCTION NOTES 1. EXISTING FEATURES, PROTECT THE FOLLOWING: A. PROTECT EXISTING UTILITES, ANY DAMAGE TO THE EXISTING UTILITIES THAT ARE NOT SCHEDULED FOR MODIFICATION OR DEMOLITION SHALL BE REMEDIED AT THE CONTRACTORS EXPENSE WITH WORK BEING PERFORMED TO THE UTILITY OWNER'S SPECIFICATION. 2. CRITICAL CROSSING. CONTRACTOR TO VERIFY ALL CROSSINGS AND PROVIDE 18" MINIMUM SEPARATION. 3. ROOF DRAINS. COORDINATE EXACT SIZE, LOCATION, AND ELEVATION WITH MECHANICAL PLANS PRIOR TO CONSTRUCTION. GENERAL CONSTRUCTION NOTES A. NOTIFY THE CITY OF WAUKEE AT LEAST 48 HRS PRIOR TO CONNECTING TO ANY PUBLIC UTILITY. B. ALL UTILITIES SHALL BE TESTED TO THE CITY OF WAUKEE STANDARD SPECIFICATION FOR PUBLIC IMPROVEMENTS AND ANY TESTING OR TIE-INS SHALL BE WITNESSED BY THE CITY OF WAUKEE ENGINEERING DEPARTMENT. C. ALL SANITARY SEWER AND STORM SEWER SHALL BE CLEANED AND TELEVISED PRIOR TO PAVING. THE CITY OF WAUKEE SHALL WITNESS ALL CLEANING AND TELEVISING. COPIES OF THE REPORT AND VIDEO SHALL BE PROVIDED TO THE CITY OF WAUKEE. ALL SANITARY SEWER MANHOLES SHALL BE VACUUM TESTED. D. ALL WATERMAIN SHALL BE PRESSURE AND BACTERIA TESTED AND DECHLORINATED. 1 C301 ST-6B DETAIL NO SCALE PROFILE VIEW 30" 30 DEG STAINLESS STEEL V-WEIR PLATE ELEV (WQV)=1052.3912" OUTLET PIPE INV=1050.95 ACCESS MANHOLE RIM=1056.95 BOTTOM OF BASIN ELEV=1050.95 1. 8 9 ' TOP OF WEIR ELEV=1054.28 6" ADS N-12 DUAL WALL PERFORATED SUBDRAIN INV=1051.00 12" OUTLET PIPE INV=1050.95 12" X 12" MANIFOLD ELEV=1052.54 18" ACCESS PIPE ELEV=1051.51 PLAN VIEW 30" 3 0 ° 30 DEG V-WEIR ELEV (WQV)=1052.39 TOP OF WEIR ELEV=1054.28 1. 8 9 ' RIM=1056.95 BOTTOM OF BASIN ELEVATION INV: 1050.95 18" ACCESS PIPE ELEV=1051.51 12" X 12" MANIFOLD ELEV=1052.54 3" ORIFICE INV: 1050.95 EXISTING 8" WATER MAIN 3" ORIFICE INV: 1050.95 6" PERFORATED SUBDRAIN INV=1051.00 BOTTOM OF BASIN ELEV=1050.95 FIRE RISER ROOM PROPOSED BUILDING 11,890 SF T 1454 1458 1462 1466 1474 1478 1482 TRASH TRASH 10' Existing Public Utility Easement (Bk 2015, Pg 20833) 10' Existing Public Utility Easement (Bk 2015, Pg 20833) 10' Existing Public Utility Easement (Bk 2019, Pg 21475) 20' Existing Storm Sewer Easement (Bk 2015, Pg 20833) Existing Public Sidewalk Easement (Bk 2019, Pg 21474) 10' Existing Sanitary Sewer Easement (Bk 2015, Pg 20833) 15' Existing Private Sanitary Sewer Easement (Bk 2022, Pg 9126) Existing 30' Private Access Easement (Bk 2022, Pg 9126) 20' Existing Private Storm Sewer Easement (Bk 2015, Pg 20839) Existing 30' Private Access Easement (Bk 2022, Pg 9126) 25' B U I L D I N G S E T B A C K 30' BUILDING SETBACK 1475 SE BISHOP DR 10' Existing Gas Easement (Bk 2022, Pg 9125) LOT 2 COVE A T K E T T L E S T O N E P L A T 3 OWNER : S P L A S H E S P R E S S , L L C ZONING : C - 1 / P D - 1 S E BIS H O P DRIVE 70.00'R O W 75,242 SF 1.73 AC LOT 1 N0 ° 1 1 ' 2 0 " E 3 0 1 . 5 9 ' M N0 ° 1 0 ' 3 1 " E 3 0 1 . 7 0 ' P S89°48'38"E 253.72' M S89°48'30"E 253.77' P S0 ° 1 9 ' 4 1 " W 2 7 0 . 0 0 ' M N0 ° 1 9 ' 3 5 " E 2 7 0 . 0 0 ' P N89°59'54"W 114.03' S38 ° 2 4 ' 5 9 " W 1 0 6 . 7 2 ' C 7 C 8 Existing Feeder Main Easement (Bk 2005, Pg 1875) Existing Feeder Main Easement (Bk 2005, Pg 1875) SE UNIVERSITY AVE 60.00' HALF ROW 10' Private Water Easement 15' Private Storm Sewer Easement Existing Storm Sewer Easement (Bk 2006, Pg 13760) 100 H YD D DEX STORM MHRIM=1048.73 D DEX STORM MHRIM=1053.43 F/O E E F/O F/O EX INTAKET/C=1053.27 EX 12" RCP FESFL=1041.39 RIM=1059.86 T 1 0 5 7 1057 1057 1058 1058 1058 1055 1053 1054 1056 10561056 10 5 6 10 5 6 1057 105 7 10 5 7 1 0 5 7 10 5 7 1 0 5 0 1 0 5 5 1 0 4 9 1 0 5 1 1 0 5 2 1 0 5 3 1 0 5 4 1 0 5 6 1 0 5 7 105 8 1058 105 8 1 0 5 8 1 0 5 9 10 6 5 10 6 5 10 7 0 10 6 0 10 6 5 1055 10601060 10 6 0 ● ● ● ● ●● ●●●●●●● ● ● ● SILT FENCE (TYP.) 10 TONS CLASS E RIPRAP (9'X5'X1.5') ● ● ● ● ● ● ● STABILIZED CONSTRUCTION ENTRANCE SILT FENCE (TYP.) STAGING AREA ●●●●●●●●●●●●● TOPSOIL STOCKPILE AREA● ●● SILT FENCE (TYP.) FILTER SOCK ● ● ● ● ● ● ● ● ● SEDIMENT BASKETSEDIMENT BASKET SEDIMENT BASKET SEDIMENT BASKET CONCRETE WASHOUT - 2 . 0 3 % ●● ● ● 10 TONS CLASS E RIPRAP (11'X5'X1.5') DISTURBANCE LIMIT PROTECT EXISTING FES UNTIL REMOVAL ULTIMATE DISCHARGE TO WALNUT CREEK ULTIMATE DISCHARGE TO WALNUT CREEK 1045 1050 1055 1046 104710481049 1051 1052 1053 1054 1056 10 4 2 1043104 4 10 5 0 10 5 5 1 0 4 6 10 4 7 1 0 4 8 1 0 4 9 1051 105 2 105 3 10 5 4 105 6 105 7 105 8 FFE = 1058.10 HYDROMULCH WITH BFM OR APPROVED EQUAL ALONG STEEP SLOPES TO MEET SUDAS 7E-17 REQUIREMENTS HYDRODYNAMIC SEPARATOR (POST CONSTRUCTION) UG CHAMBERS (POST CONSTRUCTION) SEDIMENT BASKET SILT FENCE (TYP.) 1 0 5 7 1057 MODIFIED SOILS AND ROCK LAYER FOR SOUTH INFILTRATION BASIN SEE DETAIL 3/C600 V: \ P r o j e c t s \ 2 0 2 1 \ 1 2 1 . 1 2 2 2 . 0 1 A \ C A D D \ S P _ 1 2 1 1 2 2 2 A _ E R O S . d w g LO G A N M Y E R S , ER O S I O N & S E D I M E N T C O N T R O L P L A N , 20 2 3 / 0 2 / 2 8 , 3: 2 9 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 30 BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m KM M LJ M KS 11 - 0 7 - 2 2 30 ' 12 1 . 1 2 2 2 . 0 1 A C4 0 0 121.1222.01A C400 CO V E A T K E T T L E S T O N E P L A T 4 , L O T 1 ER O S I O N & S E D I M E N T C O N T R O L P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 01 - 1 0 - 2 3 01 - 3 1 - 2 3 02 - 1 4 - 2 3 02 - 2 8 - 2 3 KS LJ M LJ M LJ M 3456 TT N - R R W - S S QUANTITIES SUDAS TYPE 4 SEEDING, FERTILIZING & MULCHING 1.88 AC. DETENTION BASIN SEEDING 0.13 AC. SOD 0.58 AC. SILT FENCE 962 LF FILTER SOCK 195 LF SEDIMENT BASKETS 4 EA CLASS E RIP-RAP 20 TONS DISTURBED AREA 1.88 AC. BFM HYDROMULCH 0.09 AC. TYPICAL SILT FENCE INSTALLATION ON LONGITUDINAL SLOPES (Profile View) FLOW 'T ' S T E E L FE N C E P O S T 4' - 0 " M I N SEE PLANS FOR SPACING TYPICAL SILT FENCE INSTALLATION ON LONGITUDINAL SLOPES (Plan View) DETAILS OF SILT FENCE ON LONGITUDINAL SLOPES ATTACHMENT TO POST 200'-0" MAX LENGTH PER SECTION 600'-0" IF SLOPE IS FLATTER THAN 5% 36 " 24 " 8'-0" SPACING TYPICAL SILT FENCE DITCH CHECK BAC K S L O P E FO R E S L O P E VARIABLE (20'-0" FOR A NORMAL 10'-0" WIDE DITCH) POST SPACING (5'-0" MAX) POST SPACING 5'-0" MAX) 2" MI N 20 " M I N 1 1 2 GROUND LINE FABRIC GROUND CONTOURS INSTALL "J-HOOK" AT EACH END OF AN INDIVIDUAL SECTION OF SILT FENCE INSTALL PARALLEL TO GROUND CONTOUR FABRICGROUND LINE FABRIC POST WIRE OR CABLE TIES 2 2 1 C400 SILT FENCE DETAIL NO SCALE 1 INSERT 12 INCHES OF FABRIC A MINIMUM OF 6 INCHES DEEP (FABRIC MAY BE FOLDED BELOW THE GROUND LINE. 2 REDUCE POST SPACING TO 5'-0" AT WATER CONCENTRATION AREAS, OR AS REQUIRED TO ADEQUATELY SUPPORT FENCE. 1.UTILITY WARNING: THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR RECORDS OBTAINED. THE SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEY FURTHER DOES NOT WARRANT THAT THE UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED. 2.NOTIFY UTILITY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXISTENCE, EXACT LOCATION AND DEPTH OF ALL UTILITIES. AVOID DAMAGE TO UTILITIES AND SERVICES DURING CONSTRUCTION. ANY DAMAGE DUE TO THE CONTRACTOR'S CARELESSNESS SHALL BE CORRECTED AT THE CONTRACTOR'S EXPENSE. COORDINATE ANY UTILITY RELOCATIONS WITH UTILITY PROVIDER. 3.ALL PROPOSED CONTOURS AND SPOT ELEVATIONS SHOWN ARE FINISHED GRADES AND/OR TOP OF PAVING SLAB (GUTTER), UNLESS OTHERWISE NOTED. 4.ALL STORM SEWER PIPE LENGTHS ARE MEASURED FROM CENTER OF STRUCTURE TO CENTER OF STRUCTURE AND INCLUDE FLARED END SECTION. 5.CONTRACTOR TO STRIP AND STOCKPILE TOPSOIL FROM ALL AREAS TO BE CUT OR FILLED. RESPREAD TO MINIMUM 8" DEPTH TO FINISH GRADES. 6.THE CONTRACTOR IS RESPONSIBLE FOR CLEANING DIRT AND DEBRIS FROM STREETS, DRIVEWAYS AND SIDEWALKS CAUSED BY CONSTRUCTION ACTIVITIES BY THE END OF THE WORK DAY AND PRIOR TO A RAIN EVENT. 7.SLOPES OF ALL UNPAVED AREAS TO BE 2.0% MINIMUM. 8.CONTRACTOR TO CONTAIN SAWCUTTING/GRINDING SLURRY ON SITE AND DISPOSE OF ACCORDING TO IOWA DNR GENERAL PERMIT NO. 2 GRADING NOTES FIRE RISER ROOM PROPOSED BUILDING 11,890 SF T 1454 1458 1462 1466 1474 1478 1482 TRASH TRASH 10' Existing Public Utility Easement 15' Existing Private Sanitary Sewer Easement (Bk 2022, Pg 9126) 20' Existing Private Storm Sewer Easement (Bk 2015, Pg 20839) Existing 30' Private Access Easement (Bk 2022, Pg 9126) 30' BUILDING SETBACK 1475 SE BISHOP DR LOT 2 COVE A T K E T T L E S T O N E P L A T 3 OWNER : S P L A S H E S P R E S S , L L C ZONING : C - 1 / P D - 1 75,242 SF 1.73 AC LOT 1 N0 ° 1 1 ' 2 0 " E 3 0 1 . 5 9 ' M N0 ° 1 0 ' 3 1 " E 3 0 1 . 7 0 ' P S89°48'38"E 253.72' M S89°48'30"E 253.77' P S0 ° 1 9 ' 4 1 " W 2 7 0 . 0 0 ' M N0 ° 1 9 ' 3 5 " E 2 7 0 . 0 0 ' P N89°59'54"W 114.03' S38 ° 2 4 ' 5 9 " W 1 0 6 . 7 2 ' C 7 C 8 SE UNIVERSITY AVE 60.00' HALF ROW 10' Private Water Easement 15' Private Storm Sewer Easement Existing Storm Sewer Easement (Bk 2006, Pg 13760) 1058.40 TC 1057.90 G 1058.12 TC 1057.62 G 10 5 8 . 1 0 T C 10 5 7 . 6 0 G 1058.06 TC 1057.56 G 1057 . 4 0 T C 1056 . 9 0 G 1057.67 TC 1057.17 G 1057.49 TC 1056.99 G 1057.81 TC 1057.31 G 105 7 . 5 0 T C 105 7 . 0 0 G 1058.17 TC 1057.67 G 1058.36 TC 1057.86 G 1058.51 TC 1058.01 G 1058.69 TC 1058.19 G 1059.12 TC 1058.62 G (10 5 7 . 7 8 ) (1057.81) (105 8 . 3 2 ) (10 5 7 . 6 2 ) (1 0 5 8 . 0 0 ) (105 8 . 9 1 ) (105 9 . 2 6 ) 1058. 1 0 FFE=1058.10 (1056.83)(1056.99) (1 0 5 7 . 0 0 ) (105 6 . 9 3 ) (1056.14) (???) (1055.95) (10 5 5 . 7 1 ) (1056.29) (1056.99) (1056.89)(1 0 5 9 . 4 5 ) 1059. 8 4 T C 1059. 3 4 G (1 0 5 9 . 3 9 ) (1059.66) (1059.66) 1058 . 1 2 T C 1057 . 6 2 G 1057 . 1 1 1057 . 6 9 T C 1057 . 1 9 G 1057.90 TC 1057.40 G OVERFLOW 1057.29 TC 1056.79 G 1057.95 TC 1057.45 G 1057.82 TC 1057.32 G 1057.85 T C 1057.35 G 1057.89 TC 1057.39 G 1057.81 TC 1057.31 G OVERFLOW 1057.86 TC 1057.36 G 1057.68 TC 1057.18 G 105 7 . 8 9 T C 105 7 . 3 9 G 105 7 . 8 6 T C 105 7 . 3 6 G 1057.51 TC 1057.01 G 1057.64 TC 1057.14 G 1057.80 TC 1057.30 G 1056.80 TC 1056.30 G 105 6 . 9 1 1056.61 1057.16 1056.61 10 5 7 . 3 3 1 0 5 7 . 8 8 105 7 . 5 9 1057.14 105 7 . 2 7 1058.53 OVERFLOW 1056.17 TC 1055.67 G1056.46 TC 1055.96 G 1056.83 TC 1056.33 G 1057.45 TC 1056.95 G 1057.45 TC 1056.95 G 1057.18 TC 1056.68 G 1056.84 TC 1056.34 G 1056.37 1057.09 TC 1056.59 G 10 5 8 . 3 3 T C 10 5 7 . 8 3 G 10 5 8 . 1 4 T C 105 7 . 6 4 G 1058.06 TC 1057.56 G 1056.21 (MATCH EXISTING) 105 5 . 9 8 1056.87 1056.74 (1056.60) (1056.75) 1057. 8 0 105 7 . 9 0 1057 . 4 3 1057 . 3 0 1057.20 1057.20 1058.70 1058.70 1058 . 7 0 1058.7 0 -3 . 4 3 % -4 . 2 0 % -3 . 3 5 % -2 . 0 0 % 10 5 8 . 0 0 10 5 8 . 0 0 105 7 . 7 5 10 5 8 . 1 0 10 5 8 . 1 0 10 5 8 . 1 0 10 5 8 . 1 0 100-YEAR ELEVATION: 1057.10 - 2 . 0 1 % 10 6 5 106 5 10 7 0 10 5 5 1055 1 0 6 0 1 0 6 5 1055 10601060 10 6 0 1 0 5 5 1 0 5 3 1 0 5 4 1 0 5 6 1 0 5 7 105 8 1 0 6 0 10 6 5 1059.20 105 9 . 1 0 10 5 9 . 1 0 HP HP 1059.8 0 T C 1059. 3 0 G 1059 . 7 1 T C 1059 . 2 1 G (105 5 . 7 3 ) (105 5 . 8 3 ) (105 7 . 2 0 ) (1055.70) (1056 . 0 0 ) (1058.2 7 ) (1059.75) (1060.04 ) (1058.46) (1058.52) (1058 . 4 8 ) (1059.61) (1059.70) (1059.6 0 ) (1059.55 ) (1059 . 4 1 ) (1059 . 4 3 ) 1059 10 5 9 10 6 0 1 0 5 8 1058 1058 1058 10 5 8 105 9 1060 105 9 105 8 1057 1056 1058 1056 1055 1054 1056 1057 1057 10 5 6 1 0 5 7 1057 105 9 1 0 5 9 1 0 5 8 10 5 8 1057 1057 -4.0 : 1 -4.0 : 1 -4.0:1 - 4 . 0 : 1 -4 . 0 : 1 -2.28% OVERFLOW 1 0 5 5 1 0 5 5 1 0 5 1 1 0 5 2 1 0 5 3 10 5 6 10 5 7 10 5 8 1 0 5 5 1053 1054 1056 10 5 6 10 5 6 1057 1057 10 5 7 10 5 7 10 5 7 1 0 5 7 10 5 7 1057 1058 10 5 8 1058 1 0 5 8 1 0 5 9 100-YEAR ELEVATION: 1056.81 100-YEAR ELEVATION: 1056.46 1057.97 TC 1057.47 G -2.23%-2.06% OVERFLOW 1057.29 TC 1056.79 G (105 8 . 9 6 ) (10 5 9 . 0 4 ) (10 5 8 . 3 4 ) (1058 . 4 0 ) -1 . 2 9 % -1 . 8 0 % -0 . 8 0 % -2.26% -0.99% -2.48% -2 . 1 6 % -1 . 0 5 % -1 . 1 3 % -1 . 0 1 % -1 . 2 5 % -4.15% -5.34% HP HP 100-YEAR ELEVATION: 1056.81 1056.27 TC 1055.77 G -4 . 0 0 % -1 . 5 0 % -1 . 5 0 % 100-YEAR ELEVATION: 1057.67 10 5 7 . 5 0 1057.44 1058 . 1 0 1058 . 1 0 1056.97 1057.20 TC 1056.70 G 100-YEAR ELEVATION: 1057.06 -2 . 0 0 % -1 . 5 0 % -1 0 . 0 5 % -4 . 0 0 % -4 . 4 0 % -8 . 0 9 % 1057.831059.43 1058. 4 3 1057.92 1056.4 71056.69 -4 . 5 4 % OVERFLOW TO ST-6 1057.13 (MATCH EXISTING) (MATCH EXISTING) (MATCH E X I S T I N G ) (MATCH EX I S T I N G ) 100-YEAR ELEVATION: 1055.75 105 7 -1 . 4 2 % -0 . 5 8 % 105 7 . 8 4 T C 105 7 . 3 4 G 1057.73 105 7 . 6 8 1057.46 105 6 . 4 9 1056 . 4 0 105 7 . 1 0 105 7 . 1 2 -1.90% -1 . 5 0 % -7 . 5 8 % -1 . 4 2 % 105 6 . 6 7 1 0 5 7 . 1 8 1056 . 8 3 105 6 . 9 1 -1 . 5 0 % -6 . 3 6 % -5 . 8 8 % 1 0 5 7 . 4 3 0.00% -1 . 5 0 % -1.94% -1.21%-1 . 5 7 % -1.70% -1 . 5 0 % -5.21% -6.39% -1.28% -0 . 6 6 % -0 . 5 9 % 1056.83 -7 . 5 0 % -1.79% -1 . 5 6 % -0.48% 0.45% 1 0 5 7 . 8 2 105 7 . 8 2 1 0 5 7 . 7 4 1056.40 -1.09% -0.96% 1 0 5 7 . 3 9 1 0 5 7 . 5 0 105 6 . 9 1 (105 6 . 9 3 ) (1056.14) 1 0 5 7 . 6 6 T C 1 0 5 7 . 1 6 G 105 7 . 8 9 T C 105 7 . 3 9 G 105 7 . 8 6 T C 105 7 . 3 6 G 1057.51 TC 1057.01 G1057 . 6 6 1057 . 9 0 1057 . 7 5 105 7 . 5 9 (1056.60)(105 6 . 8 6 ) -4 . 2 0 % -3 . 3 5 % 105 7 . 7 5 10 5 8 . 1 0 10 5 8 . 1 0 105 8 . 1 0 105 8 . 1 0 1 0 5 8 . 1 0 10 5 8 . 1 0 105 7 . 9 1 T C 105 7 . 4 1 G 1057.17 1057. 2 6 1057. 5 8 1057 . 6 4 1057.35 1057. 2 6 1057.18 1057.08 105 7 . 7 8 T C 105 7 . 2 8 G -1 . 7 5 % -0.99% -1.00%-1.00% -1.01% -0.95% -1.10% -1.00%-1.82% -1.02%-0.78% -1 . 7 5 % -1 . 6 0 % -1 . 5 9 % -0 . 8 0 % -1 . 6 5 % 10 5 7 . 8 7 1058.001058.00 105 8 . 1 0 1 0 5 8 . 1 0 10 5 7 . 7 0 1057 . 8 0 -1 . 4 9 % -4 . 8 1 % -4 . 6 7 % 0.00% -0 . 7 8 % 0.89%-1.60% 0.00% 10 5 7 1057 10 5 8 -1 . 8 0 % (105 6 . 8 2 ) (105 6 . 7 9 ) (105 6 . 9 0 ) (105 6 . 9 9 ) -2.22% -0 . 7 0 % -0.65% -0.43% -0 . 5 3 % -0.19% -1.53% 0.00% -1 . 1 8 % 10 5 7 . 9 5 1 0 5 7 . 7 5 10 5 7 . 5 0 1057.44 -0 . 7 9 % -0 . 3 7 % -0.00% -0.43% 105 7 . 7 6 T C 105 7 . 2 6 G 10 5 7 . 8 0 -1 . 2 7 % -1 . 6 2 % -0.43% 0.00% 1 0 5 7 . 7 0 T C 1 0 5 7 . 2 0 G -1.38% -1.71% -1 . 5 0 % -1 . 0 6 % 0.94%105 7 . 5 5 G 1.41% 1 0 5 7 . 9 5 -1 . 4 2 % -0 . 5 8 % -1 . 1 1 % -1 . 4 7 % 105 8 . 1 0 105 8 . 1 0 105 8 . 1 0 105 8 . 1 0 105 8 . 1 0 105 8 . 1 0 105 8 . 1 0 105 8 . 1 0 1057. 7 8 0. 5 6 % 105 7 . 8 4 T C 105 7 . 3 4 G 1 0 5 7 . 6 5 T C 1 0 5 7 . 1 5 G 1.73 AC 1057.16 10 5 7 . 3 3 105 7 . 9 0 -2 . 0 0 % -0 . 3 8 % -1 . 0 5 % -0 . 5 0 % -0 . 5 0 % -0 . 3 8 % -4.29% -0.00% -1.18% -1.01%0.00%-1.01% 10 5 7 . 3 3 10 5 7 . 2 4 105 7 . 4 2 1057.42 10 5 7 . 2 4 -2 . 0 0 % -2 . 0 0 % -1 . 5 4 % -1 . 5 3 % -1 . 5 2 % 1058. 0 2 105 8 . 0 0 105 7 . 5 1 1 0 5 7 . 5 4 105 7 . 9 0 1 0 5 7 . 9 0 -1 . 5 3 % -1 . 8 6 % 1057.81 TC 1057.31 G -0.00% -0.00%-4.29%-4.05% -4.27% 1057. 8 2 T C 1057. 3 2 G -1.18% 1058. 1 0 1058. 1 0 1058. 1 0 1058 . 1 0 1057 . 9 0 1057. 9 0 -1 . 5 3 % 0.00% -1 . 5 3 % 0.00% 0.00% 105 7 . 3 1 1057.81 TC 1057.31 G 1057.81 TC 1057.31 G 0.00%-1 . 5 0 % -2 . 0 0 % -2 . 0 0 % -2 . 0 0 % -1 . 7 0 % -1 . 5 0 % 0.25% 0.00% -0.00% 1058.06 TC 1057.56 G 1057.81 TC 1057.31 G 105 7 . 9 0 1057 . 9 0 105 7 . 9 5 10 5 8 . 0 0 1058 . 0 3 10 5 7 . 9 0 10 5 7 . 9 0 1057.81 TC 1057.31 G 1057.81 TC 1057.31 G 1057.81 TC 1057.31 G 1058.03 TC 1057.53 G -1 . 1 2 % -1 . 5 3 % -0.00% 0.43%-1 . 5 2 % -1 . 5 2 % 0.00% 0.00%-0 . 2 1 % -1.50% -0 . 0 9 % -1.42% -0.52% -1.09% 105 8 . 1 0 105 8 . 1 0 105 8 . 1 0 105 8 . 1 0 1057.89 TC 1057.39 G 1 0 5 7 . 8 2 T C 1 0 5 7 . 3 2 G 1057.80 TC 1057.30 G 1057 . 9 0 105 7 . 9 0 1 0 5 7 . 9 0 1057.87 -2 . 0 0 % 10 5 8 . 0 0 -2 . 1 6 % -4.15% -0 . 0 0 % -1.37% -0.51% -0 . 8 1 % 1 0 5 7 . 8 1 1 0 5 7 . 8 1 -1 . 5 2 % -1 . 5 2 % 0.00% 0.00% 0.00% -1 . 1 6 % -0 . 9 2 % -0.26% 1057 . 9 0 1 0 5 7 . 8 5 1 0 5 7 . 8 4 1057.82105 7 . 9 0 1058 . 1 0 1058 . 1 0 1058 . 1 0 1058 . 1 0 -1 . 4 8 % -1.17% -1 . 5 0 % -1.18% 10 5 8 . 1 3 1058 . 0 7 105 8 . 1 5 105 8 . 2 0 V: \ P r o j e c t s \ 2 0 2 1 \ 1 2 1 . 1 2 2 2 . 0 1 A \ C A D D \ S P _ 1 2 1 1 2 2 2 A _ G R D G . d w g LO G A N M Y E R S , DE T A I L E D G R A D I N G P L A N , 20 2 3 / 0 2 / 2 8 , 3: 2 9 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 20 BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m KM M LJ M KS 11 - 0 7 - 2 2 20 ' 12 1 . 1 2 2 2 . 0 1 A C4 0 1 121.1222.01A C401 CO V E A T K E T T L E S T O N E P L A T 4 , L O T 1 DE T A I L E D G R A D I N G P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 01 - 1 0 - 2 3 01 - 3 1 - 2 3 02 - 1 4 - 2 3 02 - 2 8 - 2 3 KS LJ M LJ M LJ M 3456 TT N - R R W - S S 1.UTILITY WARNING: THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR RECORDS OBTAINED. THE SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEY FURTHER DOES NOT WARRANT THAT THE UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED. 2.NOTIFY UTILITY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXISTENCE, EXACT LOCATION AND DEPTH OF ALL UTILITIES. AVOID DAMAGE TO UTILITIES AND SERVICES DURING CONSTRUCTION. ANY DAMAGE DUE TO THE CONTRACTOR'S CARELESSNESS SHALL BE CORRECTED AT THE CONTRACTOR'S EXPENSE. COORDINATE ANY UTILITY RELOCATIONS WITH UTILITY PROVIDER. 3.ALL PROPOSED CONTOURS AND SPOT ELEVATIONS SHOWN ARE FINISHED GRADES AND/OR TOP OF PAVING SLAB (GUTTER), UNLESS OTHERWISE NOTED. 4.ALL STORM SEWER PIPE LENGTHS ARE MEASURED FROM CENTER OF STRUCTURE TO CENTER OF STRUCTURE AND INCLUDE FLARED END SECTION. 5.CONTRACTOR TO STRIP AND STOCKPILE TOPSOIL FROM ALL AREAS TO BE CUT OR FILLED. RESPREAD TO MINIMUM 8" DEPTH TO FINISH GRADES. 6.THE CONTRACTOR IS RESPONSIBLE FOR CLEANING DIRT AND DEBRIS FROM STREETS, DRIVEWAYS AND SIDEWALKS CAUSED BY CONSTRUCTION ACTIVITIES BY THE END OF THE WORK DAY AND PRIOR TO A RAIN EVENT. 7.SLOPES OF ALL UNPAVED AREAS TO BE 2.0% MINIMUM. GRADING NOTES 1 C401 SIDEWALK RAMP AND ADA STALLS DETAILS 1" = 10' T 75,242 SF 1.73 AC LOT 1 N0 ° 1 1 ' 2 0 " E 3 0 1 . 5 9 ' M N0 ° 1 0 ' 3 1 " E 3 0 1 . 7 0 ' P S89°48'38"E 253.72' M S89°48'30"E 253.77' P S0 ° 1 9 ' 4 1 " W 2 7 0 . 0 0 ' M N0 ° 1 9 ' 3 5 " E 2 7 0 . 0 0 ' P N89°59'54"W 114.03' S38 ° 2 4 ' 5 9 " W 1 0 6 . 7 2 ' C 7 C 8 SE UNIVERSITY AVE 60.00' HALF ROW 100 1 - CP E TYP. E TYP. TYP. J J G G E TYP.ETYP. E ETYP.TYP. F G E TYP. H 1 - AO 1 - AO 1 - GP 5 - BG 5 - PO 5 - PO 3 - BG 5 - PO 5 - BG5 - PO7 - BG 9 - PO 13 - CK 1 - AG 1 - AG E 5 - PO F F 2 - TC 1 - PC 1 - PC 1 - PC 1 - GP 1 - CP 1 - CP 1 - GP 1 - CP 1 - CP 1 - GP 5 - BG5 - BG 4 - CK 3 - CK 3 - SB 3 - CK 3 - SD 7 - CK 2 - SB 12 - BG 3 - SB 5 - CK 4 - SB S E B I S H O P D R I V E 3 - CK 3 - SB 2 - TT 3 - SB 3 - SB 3 - VR 3 - SB 3 - VR 7 - CK 3 - SB 3 - SB 4 - TT 4 - CK 4 - CK 4 - CK 3 - SD 3 - SD 6 - CK V: \ P r o j e c t s \ 2 0 2 1 \ 1 2 1 . 1 2 2 2 . 0 1 A \ C A D D \ S P _ 1 2 1 1 2 2 2 A _ L N D . d w g LO G A N M Y E R S , PL A N T I N G P L A N , 20 2 3 / 0 2 / 2 8 , 3: 2 9 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 20 BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m KM M LJ M KS 11 - 0 7 - 2 2 20 ' 12 1 . 1 2 2 2 . 0 1 A C5 0 0 121.1222.01A C500 CO V E A T K E T T L E S T O N E P L A T 4 , L O T 1 PL A N T I N G P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 01 - 1 0 - 2 3 01 - 3 1 - 2 3 02 - 1 4 - 2 3 02 - 2 8 - 2 3 KS LJ M LJ M LJ M 3456 TT N - R R W - S S PLANTING PLAN GENERAL NOTES A.UTILITY WARNING: THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR RECORDS OBTAINED. THE SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEY FURTHER DOES NOT WARRANT THAT THE UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED. B. NOTIFY UTILITY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXISTENCE, EXACT LOCATION AND DEPTH OF ALL UTILITIES. AVOID DAMAGE TO UTILITIES AND SERVICES DURING CONSTRUCTION. ANY DAMAGE DUE TO THE CONTRACTOR'S CARELESSNESS SHALL BE CORRECTED AT THE CONTRACTOR'S EXPENSE. COORDINATE AND COOPERATE WITH UTILITY COMPANIES DURING CONSTRUCTION. C. ALL PLANT MATERIAL SHALL AT LEAST MEET MINIMUM REQUIREMENTS SHOWN IN THE "AMERICAN STANDARDS FOR NURSERY STOCK" (ANSI Z60.1-LATEST EDITION). D. CONTRACTOR SHALL GUARANTEE ALL PLANT MATERIAL FOR A PERIOD OF ONE YEAR FROM DATE OF INSTALLATION. E. PROVIDE 1" CLEAN RIVER ROCK MULCH TO 3-INCH DEPTH AROUND ALL PLANTINGS TO A MIN. 3-FOOT PERIMETER, AND IN ALL AREAS INDICATED ON PLAN. F. CONTRACTOR TO INSTALL BLACK METAL EDGING AROUND ALL INDIVIDUAL TREE PLANTINGS AND AT PERIMETER OF ALL PLANTING BEDS UNLESS OTHERWISE DIRECTED BY OWNER. G. SOD ALL DISTURBED AREAS UNLESS NOTED OTHERWISE. REFER TO EROSION CONTROL PLAN FOR ADDITIONAL INFORMATION. H. PROVIDE DETENTION BASIN SEED MIX AS PROVIDED BY PRAIRIE MOON NURSERY. WWW.PRAIRIEMOON.COM, 32115 PRAIRIE LANE, WINONA, MN 55987, OR APPROVED EQUAL SEEDING RATE: 11.48 LBS/ACRE. INSTALL AS PER SUDAS SPECIFICATIONS 9010 SEEDING. PROVIDE REGREEN, Tricitum aestivum, SHORT-LIVED STERILE PERENNIAL WHEAT/WHEAT GRASS HYBRID OR APPROVED EQUAL. APPLY AT 30 LBS/ACRE. I. PLANTING SUBSTITUTIONS SHALL BE APPROVED IN WRITING BY THE COMMUNITY DEVELOPMENT DEPARTMENT. J. ALL AREAS IN THE RIGHT-OF-WAY WILL BE REQUIRED TO BE SODDED. (ALONG BOTH SE UNIVERSITY AVE. AND SE BISHOP DRIVE). PLANTING PLAN REQUIREMENTS (LANDSCAPE CALCULATIONS BASED UPON CITY OF WAUKEE ZONING CODE REQUIREMENTS AND THE KETTLESTONE DESIGN GUIDELINES PUD) 15% OPEN SPACE REQUIRED 75,242 SF (TOTAL LOT) x 15% = 11,286.3 SF REQUIRED (31,038 SF OR 41.25% PROVIDED) 1 OVERSTORY TREES, 0.5 UNDERSTORY TREES, AND 2 SHRUBS PER 1,000 SF OF REQUIRED OPEN SPACE. MINIMUM OF 50% OF TOTAL REQUIRED TREES SHALL BE OVERSTORY SHADE TREES. 11,286.3/1,000 = 11.286 PLANT UNITS (PU'S) 1 OVERSTORY TREES x 11.286 PU'S = 11.29 OVERSTORY TREES REQUIRED (12 TREES PROVIDED; 9 DECIDUOUS, 3 EVERGREEN) 0.5 UNDERSTORY TREES x 11.286 PU'S = 5.64 UNDERSTORY TREES REQUIRED (6 UNDERSTORY TREES PROVIDED) 2 SHRUB x 11.286 PU'S = 22.57 SHRUBS REQUIRED (40 OPEN SPACE SHRUBS PROVIDED) FOUNDATION PLANTINGS: FOUNDATION PLANTINGS ARE REQUIRED AT THE BASE OF ALL BUILDINGS OFF-STREET PARKING AREAS: PARKING LOT ISLANDS SHALL HAVE A MINIMUM OF 1 OVERSTORY TREE. (6 TREES PROVIDED) BUFFER REQUIREMENT: THERE ARE NO BUFFER REQUIREMENTS. MINIMUM HEIGHT REQUIREMENTS : DECIDUOUS OVERSTORY TREES SHALL BE A MINIMUM OF 8' IN HEIGHT. EVERGREEN OVERSTORY TREES SHALL BE A MINIMUM OF 6' IN HEIGHT. DECIDUOUS ORNAMENTAL TREES SHALL BE A MINIMUM OF 6' IN HEIGHT. MINIMUM QUANTITIES: A MINIMUM OF FIFTY PERCENT (50%) OF ALL REQUIRED TREES SHALL BE OVERSTORY SHADE TREES. A MINIMUM OF TWENTY-FIVE (25%) OF ALL REQUIRED TREES SHALL BE EVERGREENS. A MINIMUM OF 1.0 OVERSTORY TREES, 0.5 UNDERSTORY TREES AND TWO (2) SHRUBS FOR EVERY 1,000 SF OF REQUIRED OPEN SPACE SHALL BE INSTALLED. FOUNDATION PLANTINGS ARE REQUIRED AT THE BASE OF ALL BUILDINGS. FOUNDATION PLANTINGS MAY INCLUDE SHRUBS, ORNAMENTAL GRASSES, PERENNIALS, AND GROUND COVERS. NOTE: QUANTITIES SHOWN ARE APPROXIMATE. CONTRACTOR TO VERIFY PLANT MATERIAL PRIOR TO BIDDING. IN THE CASE OF A DISCREPANCY, THE PLAN QUANTITY SHALL GOVERN. TREES QTY BOTANICAL NAME COMMON NAME SIZE CONTAINER AO 2 Acer rubrum 'October Glory'October Glory Red Maple 1.5" Cal.B&B CP 5 Celtis occidentalis 'Prairie Pride'Prairie Pride Hackberry 1.5" Cal.B&B TC 2 Tilia cordata Littleleaf Linden 1.5" Cal.B&B EVERGREEN TREES QTY BOTANICAL NAME COMMON NAME SIZE CONTAINER PC 3 Pinus cembra Swiss Stone Pine 6` Ht.B&B ORNAMENTAL TREES QTY BOTANICAL NAME COMMON NAME SIZE CONTAINER AG 2 Amelanchier x grandiflora 'Autumn Brilliance'Autumn Brilliance Apple Serviceberry #7 Pot GP 4 Ginkgo biloba 'Princeton Sentry'Princeton Sentry Maidenhair Tree 1.5" Cal.B&B SHRUBS QTY BOTANICAL NAME COMMON NAME SIZE CONTAINER BG 42 Buxus x 'Green Gem'Green Gem Boxwood 3 gal.Pot PO 34 Physocarpus opulifolius 'Donna May' TM Little Devil Dwarf Ninebark 3 gal.Pot SB 30 Spiraea betulifolia 'Tor Gold' TM Glow Girl Birchleaf Spirea 3 gal.Pot SD 9 Spiraea x 'NCSX2' TM Double Play Doozie Spirea 3 gal.Pot TT 6 Taxus x media 'Tauntonii'Taunton's Anglo-Japanese Yew 3 gal.Pot VR 6 Viburnum dentatum 'Rastzam'Raspberry Tart Arrowwood Viburnum 3 gal.Pot GRASSES QTY BOTANICAL NAME COMMON NAME SIZE CONTAINER CK 63 Calamagrostis x acutiflora 'Karl Foerster'Karl Foerster Feather Reed Grass 1 gal.Pot PLANT SCHEDULE BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m KM M LJ M KS 11 - 0 7 - 2 2 ## # ' 12 1 . 1 2 2 2 . 0 1 A C6 0 0 121.1222.01A C600 CO V E A T K E T T L E S T O N E P L A T 4 , L O T 1 SI T E D E T A I L S WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 01 - 1 0 - 2 3 01 - 3 1 - 2 3 02 - 1 4 - 2 3 02 - 2 8 - 2 3 KS LJ M LJ M LJ M 3456 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 1 \ 1 2 1 . 1 2 2 2 . 0 1 A \ C A D D \ S P _ 1 2 1 1 2 2 2 A _ T S H . d w g LO G A N M Y E R S , SI T E D E T A I L S , 20 2 3 / 0 2 / 2 8 , 3: 3 0 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) 1 C600 FLARED END SECTION CIRCULAR RESTRICTOR PLATE NO SCALE SECTION VIEW END VIEW 3" 6" 4' - 0 " 1'-8" 4' - 0 " VARIES TO MATCH WIDTH OF END SECTION CONCRETE FOOTING 5 8" HOLES RESTRICTOR PLATE FLARED END SECTION SEE PLAN FOR SIZES ST-4 = 3" DIA DRILL 5 8" HOLES FOR 1 2" BOLTS 3"x3"x3"x1 4" ANGLE WITH 5 8" HOLE FOR 1 2" BOLT. WELD TO RESTRICTOR PLATE. 1 4" THICK STAINLESS STEEL RESTRICTOR PLATE. GALVANIZE AFTER ANGLE BRACKET WELDS. CONCRETE FOOTING ST-4 = 3" DIA 2 C600 SW-513 OUTLET STRUCTURE (ST-4D) NO SCALE PROFILE VIEW TOP ELEV=1058.10 INLET ELEV=1056.85 (NW) (2' WIDE X 9" TALL) LOW FLOW INLET PIPE 24" 4' OUTLET PIPE=12" RCP INV=1051.10 HIGH FLOW OVERFLOW WEIR INV=1051.20 CENTER STRUCTURE ACCESS OVER RISER AND WEIR OPENING RESTRICTOR PLATE (DETAIL 1) 4 C600 STORMTECH DETAILS NO SCALE 12" INLET PIPE WITH 3" ORIFICE INV=1054.80 3 C600 INFILTRATION BASIN DETAIL NO SCALE 15" RCP 6" PERFORATED SUBDRAIN INV: 1051.20 INFILTRATION BASIN MAINTENANCE REQUIREMENTS OWNER TO PROVIDE MAINTENANCE TO INFILTRATION BASIN PER ISWMM CHAPTER 5, SECTION 3-J. 1.INSPECT THE BASIN MONTHLY, AS WELL AS AFTER EVERY MAJOR STORM TO ENSURE THE BASIN IS DRAINING WITHIN THE MAXIMUM DRAIN TIME LIMIT. 2.INSPECT ANNUALLY FOR SETTLING, CRACKING, EROSION, LEAKAGE, TREE GROWTH ON THE EMBANKMENTS, CONDITION OF THE INLET AND OUTLET CHANNELS, SEDIMENT ACCUMULATION IN THE BASIN BOTTOM, AND THE CONDITION OF THE GRASS TURF. 3.THE BASIN SHOULD BE MOWED AT LEAST TWICE A YEAR TO PREVENT WOODY GROWTH, STIMULATE GRASS GROWTH, AND ENHANCE NUTRIENT REMOVAL. 4.DO NOT MOW WHEN THE GROUND IS WET TO AVOID COMPACTION OF BOTTOM SOILS. 5.REMOVE TRASH AND DEBRIS AT LEAST TWICE A YEAR. 6" SUBDRAIN. MAINTAIN AT 0% SLOPE ST-5A SEE UTILITY PLAN FOR INVERTS ST-6B SEE UTILITY PLAN FOR INVERTS ST-7A SEE UTILITY PLAN FOR INVERTSISOLATOR ROW PLUS ELEVATION: 1051.51 12" X 12" BYPASS MANIFOLD INV: 1052.54 SC-740 CHAMBER BOTTOM ELEVATION: 1051.50 AMENDED SOIL 80% SAND 20% COMPOST FILTER SOCK ADJACENT TO MODIFIED SOIL. FILTER SOCK ADJACENT TO MODIFIED SOIL. 6" PERFORATED SUBDRAIN PIPE SEE SHEET C301 FOR INVERTS NATIVE SOIL TYPE 1 SEED MIX 0% SLOPE0% SLOPE PROVIDE 1-2" DIAMETER CLEAN AGGREGATE TO SURFACE 4:1 M A X NATIVE SOIL 4: 1 M A X 2" M I N 6" 18 " M I N 18" WIDTH VARIES NATIVE SOIL NATIVE SOIL BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m KM M LJ M KS 11 - 0 7 - 2 2 ## # ' 12 1 . 1 2 2 2 . 0 1 A C6 0 1 121.1222.01A C601 CO V E A T K E T T L E S T O N E P L A T 4 , L O T 1 SI T E D E T A I L S WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 01 - 1 0 - 2 3 01 - 3 1 - 2 3 02 - 1 4 - 2 3 02 - 2 8 - 2 3 L J M LJ M LJ M LJ M 3456 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 1 \ 1 2 1 . 1 2 2 2 . 0 1 A \ C A D D \ S P _ 1 2 1 1 2 2 2 A _ T S H . d w g LO G A N M Y E R S , SI T E D E T A I L S , 20 2 3 / 0 2 / 2 8 , 3: 3 0 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) 1 C601 STORMTECH DETAILS (CONTINUED) NO SCALE BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m KM M LJ M KS 11 - 0 7 - 2 2 ## # ' 12 1 . 1 2 2 2 . 0 1 A C6 0 2 121.1222.01A C602 CO V E A T K E T T L E S T O N E P L A T 4 , L O T 1 SI T E D E T A I L S WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 01 - 1 0 - 2 3 01 - 3 1 - 2 3 02 - 1 4 - 2 3 02 - 2 8 - 2 3 L J M LJ M LJ M LJ M 3456 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 1 \ 1 2 1 . 1 2 2 2 . 0 1 A \ C A D D \ S P _ 1 2 1 1 2 2 2 A _ T S H . d w g LO G A N M Y E R S , SI T E D E T A I L S , 20 2 3 / 0 2 / 2 8 , 3: 3 0 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) 1 C602 DOWNSTREAM DEFENDER DETAILS NO SCALE FOR INSPECTIONS, REPAIRS, AND MAINTENANCE, CONTACT HYDRO INTERNATIONAL AT 1-800-848-2706 TO SCHEDULE AN APPOINTMENT OR VISIT HYDRO-INT.COM/SERVICE FOR MORE INFORMATION. DETERMINING YOUR MAINTENANCE SCHEDULE: THE FREQUENCY OF CLEANOUT IS DETERMINED IN THE FIELD AFTER INSTALLATION. DURING THE FIRST YEAR OF OPERATION, THE UNIT SHOULD BE INSPECTED EVERY SIX MONTHS TO DETERMINE THE RATE OF SEDIMENT AND FLOATABLES ACCUMULATION. A SIMPLE PROBE SUCH AS SLUDGE JUDGE CAN BE USED TO DETERMINE THE LEVEL OF ACCUMULATED SOLIDS STORED IN THE SUMP. THIS INFORMATION CAN BE RECORDED IN THE MAINTENANCE LOG TO ESTABLISH A ROUTINE MAINTENANCE SCHEDULE. THE VACTOR PROCEDURE, INCLUDING BOTH SEDIMENT AND OIL/FLOATABLES REMOVAL, FOR A 6-FT DOWNSTREAM DEFENDER TYPICALLY TAKES LESS THAN 30 MINUTES AND REMOVES A COMBINED WATER/OIL VOLUME OF ABOUT 500 GALLONS. INSPECTION PROCEDURES: INSPECTION IS A SIMPLE PROCESS THAT DOES NOT INVOLVE ENTRY INTO THE DOWNSTREAM DEFENDER. MAINTENANCE CREWS SHOULD BE FAMILIAR WITH THE DOWNSTREAM DEFENDER AND ITS COMPONENTS PRIOR TO INSPECTION. INSPECTION REPORT IS AVAILABLE ON MANUFACTURER'S WEBSITE. SCHEDULING: IT IS IMPORTANT TO INSPECT YOUR DOWNSTREAM DEFENDER EVERY SIX MONTHS DURING THE FIRST YEAR OF OPERATION TO DETERMINE YOUR SITE-SPECIFIC RATE OF POLLUTANT ACCUMULATION. TYPICALLY, INSPECTION MAY BE CONDUCTED DURING ANY SEASON OF THE YEAR. SEDIMENT REMOVAL IS NOT REQUIRED UNLESS SEDIMENT DEPTHS EXCEED 75% OF MAXIMUM CLEAN-OUT DEPTHS STATED IN TABLE 1. FLOATABLES AND SEDIMENT CLEANOUT: FLOATABLES CLEANOUT IS TYPICALLY DONE IN CONJUNCTION WITH SEDIMENT REMOVAL. A COMMERCIALLY OR MUNICIPALLY OWNED SUMP-VAC IS USED TO REMOVE CAPTURED SEDIMENT AND FLOATABLES. FLOATABLES AND LOOSE DEBRIS CAN ALSO BE NETTED WITH A SKIMMER AND POLE. THE ACCESS PORT LOCATED AT THE TOP OF THE MANHOLE PROVIDES UNOBSTRUCTED ACCESS FOR A VACTOR HOSE AND SKIMMER POLE TO BE LOWERED TO BASE OF THE SUMP. SCHEDULING: FLOATABLES AND SUMP CLEANOUT ARE TYPICALLY CONDUCTED ONCE A YEAR DURING ANY SEASON. IF SEDIMENT DEPTHS ARE GREATER THAN 75% OF MAXIMUM CLEANOUT DEPTHS STATED IN TABLE 1, SEDIMENT REMOVAL IS REQUIRED. FLOATABLES AND SUMP CLEANOUT SHOULD OCCUR AS SOON AS POSSIBLE FOLLOWING A SPILL IN THE CONTRIBUTING DRAINAGE AREA. www.imprintarchitects.com 1/ 2 4 / 2 0 2 3 1 : 3 1 : 5 5 P M KETTLESTONE RETAIL -LOT 1 1450 SE UNIVERSITY AVE. , WAUKEE IA 50263 08 10 06 0908 01 03 0803 0707 06 0707 06 10 080808 11 02 02 05 090909 01 03 02 02 17 ' - 4 " 22 ' - 4 " 10 11 02 02 05 05 02 03 09 12 04 02 07 12 22 ' - 4 " 01 03 06 14 15 06 BUILDING MATERIAL BREAKDOWN SCHEDULE ELEVATION MASONRY STUCCO GLAZING/DOOR TOTAL WALL S.F. EAST SOUTH WEST NORTH BLDG TOTAL 1,219.58 S.F.1,041.30 S.F.807.25 S.F.3,068.13 S.F.34% 26%40% %%% 364.92 S.F.1,017.87 S.F.175.75 S.F.1,558.54 S.F.24% 65%11% 364.92 S.F.1,017.87 S.F.175.75 S.F.1,558.54 S.F.24% 65%11% 379.25 S.F.1,706.07 S.F.493.96 S.F.2,579.28 S.F. 2,150.39 S.F.4,549.06 S.F.2,065.04 S.F.8,764.49S.F.24% 52%24% 15% 66%19% www.imprintarchitects.com 1/ 2 4 / 2 0 2 3 1 : 3 1 : 5 4 P M KETTLESTONE RETAIL -LOT 1 1450 SE UNIVERSITY AVE. , WAUKEE IA 50263 1" = 10'-0"1 NORTH ELEVATION 1" = 10'-0"2 EAST ELEVATION KEYNOTE LEGEND KEY NOTE 01 BRICK A-MODULAR 02 BRICK B-MODULAR 03 BRICK A-SOLDIER COURSE 04 CAST STONE 05 24" CAST STONE BASE 06 STUCCO A 07 STUCCO B 08 PRE-MANUFACTURED METAL FRAMED CANOPY 09 ALUMINUM STOREFRONT SYSTEM W/ INSULATED GLAZING 10 PRE-FINISHED METAL CAP 11 PRE- FINISHED METAL CAP OVER E.I.F.S CORNICE 12 C.J. CONTROL JOINT 14 STUCCO TRIM 15 BRICK SILL 10 01 01 15 13 14 12 09 06 17 ' - 2 " 17 ' - 2 1 / 8 " 02 02 05 10 06 0109 06 1212 04 14 11 15 22 ' - 4 " BUILDING MATERIAL BREAKDOWN SCHEDULE ELEVATION MASONRY STUCCO GLAZING/DOOR TOTAL WALL S.F. EAST SOUTH WEST NORTH BLDG TOTAL 1,219.58 S.F.1,041.30 S.F.807.25 S.F.3,068.13 S.F.34% 26%40% %%% 364.92 S.F.1,017.87 S.F.175.75 S.F.1,558.54 S.F.24% 65%11% 364.92 S.F.1,017.87 S.F.175.75 S.F.1,558.54 S.F.24% 65%11% 379.25 S.F.1,706.07 S.F.493.96 S.F.2,579.28 S.F. 2,150.39 S.F.4,549.06 S.F.2,065.04 S.F.8,764.49S.F.24% 52%24% 15% 66%19% www.imprintarchitects.com 1/ 2 4 / 2 0 2 3 1 : 3 1 : 5 5 P M KETTLESTONE RETAIL -LOT 1 1450 SE UNIVERSITY AVE. , WAUKEE IA 50263 1" = 10'-0"1 SOUTH ELEVATION 1" = 10'-0"2 WEST ELEVATION KEYNOTE LEGEND KEY NOTE 01 BRICK A-MODULAR 02 BRICK B-MODULAR 04 CAST STONE 05 24" CAST STONE BASE 06 STUCCO A 09 ALUMINUM STOREFRONT SYSTEM W/ INSULATED GLAZING 10 PRE-FINISHED METAL CAP 11 PRE- FINISHED METAL CAP OVER E.I.F.S CORNICE 12 C.J. CONTROL JOINT 13 PRE-FINISHED COLLECTOR & DOWNSPOUT 14 STUCCO TRIM 15 BRICK SILL 6" DIA. GALVANIZED STEEL GUARDPOST-FILL W/ CONCRETE "WOOD" COMPOSITE GATE ON GALVANIZED STEEL FRAME BRICK ON 8" CMU CONCRETE SLAB P904 4 12 ' - 0 " 21'-4" 1'-10"8'-0"1'-8"8'-0"1'-10" P904 2 P904 3 PRE-FINISHED MTL COPING BRICK OVER 8" CMU 6" DIA. GALVANIZED STEEL GUARDPOST-FILL W/ CONCRETE CANE BOLT 6' - 0 " BRICK OVER 8" CMU PRE-FINISHED MTL COPING 6" DIA. GALVANIZED STEEL GUARDPOST-FILL W/ CONCRETE BRICK OVER 8" CMU PRE-FINISHED MTL COPING www.imprintarchitects.com 1/ 2 4 / 2 0 2 3 1 : 3 1 : 5 5 P M KETTLESTONE RETAIL -LOT 1 1450 SE UNIVERSITY AVE. , WAUKEE IA 50263 1/4" = 1'-0"1 TRASH ENCLOSURE - FLOOR PLAN 1/4" = 1'-0"4 TRASH ENCLOSURE - NORTH 1/4" = 1'-0"2 TRASH ENCLOSURE - EAST/ WEST 1/4" = 1'-0"3 TRASH ENCLOSURE - SOUTH EXTERIOR MATERIALS LEGEND MODULAR BRICK: A MODULAR DEPTH MANUFACTURER: ENDICOTT COLOR: MANGANESE BROWN VELOUR MODULAR BRICK: B MODULAR DEPTH MANUFACTURER: ENDICOTT COLOR: BURGANDY SANDS SQUARE EDGE CAST STONE: 4" DEPTH MANUFACTURER: MARCSTONE COLOR: 157912 TRADITION STUCCO: A MANUFACTURER: COLOR: TO BE DETERMINED TRADITIONAL STUCCO: B MANUFACTURER: COLOR: TO BE DETERMINE www.imprintarchitects.com 1/ 2 4 / 2 0 2 3 1 : 3 1 : 5 5 P M KETTLESTONE RETAIL -LOT 1 1450 SE UNIVERSITY AVE. , WAUKEE IA 50263 1978 SF SUITE 100 1514 SF SUITE 110 1513 SF SUITE 120 1647 SF SUITE 130 1514 SF SUITE140 1514 SF SUITE 150 1975 SF SUITE 160 82 SF S. 74 SF ELEC. 20'-0"20'-0"22'-0"20'-0"20'-0"24'-2 1/2" 75 ' - 8 1 / 2 " www.imprintarchitects.com 1/ 2 4 / 2 0 2 3 1 : 3 1 : 5 6 P M KETTLESTONE RETAIL -LOT 1 1450 SE UNIVERSITY AVE. , WAUKEE IA 50263 GROSS S.F. - AREA SCHEDULE SPACE USABLE AREA SUITE 100 1978 SF SUITE 110 1514 SF SUITE 120 1513 SF SUITE 130 1647 SF SUITE140 1514 SF SUITE 150 1514 SF SUITE 160 1975 SF S.82 SF ELEC.74 SF 11811 SF