Loading...
HomeMy WebLinkAbout2023-11-20 I06 Freddy's_Site Plan AGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: November 20, 2023 AGENDA ITEM: Consideration of approval of a resolution approving a site plan for Freddy’s Waukee (440 SE Alice’s Road) FORMAT: Resolution SYNOPSIS INCLUDING PRO & CON: MLY Real Estate Inc requests approval of a site plan to authorize the construction of a single-story building for a fast-food restaurant with a drive through. The building is 2,880 square feet in area and 23.5 feet in height. The site includes a patio for dining to the east of the building. A trash enclosure and small storage shed is proposed to the west of the building. A monument sign is shown at the northeast corner of the site, along SE Alice’s Road. One access will be provided into the site off of the private drive to the west. There will also be shared accesses to the adjacent lots. Pedestrian connections are provided into the site from both the existing trail along SE Alice’s Road and the private sidewalk to the west that will be constructed with this project. A total of 44 parking spaces and 10 queuing spaces are required. They are providing 50 parking spaces and 15 queuing spaces. The site will be serviced with private utilities that have been extended throughout the overall plat. Storm water detention is provided with the large pond located to the southwest, within the overall Waukee Towne Center development. The landscape plan meets the requirements of the Landscape and Open Space Ordinance. The elevations of the building are proposed to be constructed mainly of brick, EIFs, storefront system, and Nichiha panels. The trash enclosure and storage shed will be constructed of Nichiha panels. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning Commission reviewed this project at the November 14, 2023, Commission Meeting and recommended approval subject to remaining staff comments: Item 6: Approval of a Site Plan for Freddy’s Waukee (440 SE Alice’s Road) Bill Mettee, Planner, introduced the request for approval of a site plan for a commercial building, as presented by applicant MLY Real Estate Inc., represented by James Rodemeyer, PE, of Bishop Engineering. The property address is 440 SE Alice’s Road and is generally located west of SE Alice’s Road and south of SE Laurel Street, containing approximately 1.20 acres. The subject property was recently platted as part of Waukee Towne Center Plat 5. The project includes the construction of a single-story building for a fast-food restaurant with a drive through. The building is 2,880 square feet in area and 23.5 feet in height. The site includes two drive- through lanes for ordering and one drive-through for pick-up. A patio for dining is proposed along the east side of the building. A trash enclosure and small storage shed measuring just under 148 square feet, is proposed to the west of the building. A monument sign is shown at the northeast corner of the site, along SE Alice’s Road. I6 One access will be provided into the site from the private drive to the west. There will also be shared access to the adjacent lots, both to the north and to the south when those lots develop in the future. Pedestrian connections are provided into the site from both the existing trail along SE Alice’s Road and the private sidewalk to the west that will be constructed with this project. A total of 44 parking spaces and 10 queuing spaces are required for the proposed site plan. The total amount of parking proposed is 50 spaces including three (3) accessible stalls. They are providing 15 queuing spaces for the drive-through. The site will be serviced with private utilities that have been extended throughout the overall plat. Storm water detention is provided with the large pond located to the southwest, within the overall Waukee Towne Center development. A minimum of 20% of the project area is required to be open space. The total amount of open space proposed is 21.4%. The landscape plan meets the requirements of the Landscape and Open Space Ordinance. The elevations of the building are proposed to be constructed mostly of brick, EIFS, storefront system, and Nichiha panels. The trash enclosure and storage shed will be constructed of Nichiha panels and the gate for the trash enclosure will be a composite material. A photometric plan for the site lighting has been submitted and complies with the requirements of the Site Plan Ordinance. The comprehensive plan classifies the subject property as Neighborhood Commercial. The Neighborhood Commercial classification provides a variety of uses that would serve the surrounding neighborhoods and provide day-to-day goods and services for residents. The site plan is in general conformance with the Site Plan Ordinance, Comprehensive Plan, and Planned Development. Staff recommends approval of the site plan for Freddy’s Waukee, subject to remaining staff comments. Discussion as follows: • Commissioner Broderick will be recusing himself from the vote • Discussion of the building materials, specifically the Nichiha panels: Andy Kass spoke of the panel characteristics, noting that it is very durable and is commonly used in commercial projects • Discussion of shared parking: Andy shared that the businesses included in Waukee Towne Center that face SE Alice’s Road provide their own individual parking, but the remainder of the development has cross access and parking easements to share the overall shopping center area Motion by Commissioner Beenken for approval of a Site Plan for Freddy’s Waukee, seconded by Commissioner Lohse. Ayes: Koelker, Beenken, Lohse, Tessau. Recusals: Broderick. Nays: None. Motion carried. STAFF REVIEW AND COMMENT: Staff recommends approval of the site plan subject to remaining staff comments. RECOMMENDATION: Approve the resolution subject to remaining staff comments. ATTACHMENTS: I. Proposed Resolution II. Staff Report III. Site Plan & Elevations PREPARED BY: Melissa DeBoer, Planning Coordinator REVIEWED BY: THE CITY OF WAUKEE, IOWA RESOLUTION 2023- APPROVING THE SITE PLAN FOR FREDDY’S WAUKEE (440 SE ALICE’S ROAD) IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Site Plan for Freddy’s Waukee, subject to remaining staff comments on November 14, 2023; AND, WHEREAS, the Site Plan for Freddy’s Waukee is in general conformance with §160 – Site and Building Development Standards Ordinance of the Waukee Municipal Code; AND, WHEREAS, the Site Plan for Freddy’s Waukee is in general conformance with §161 – Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND, NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 20th day of November, 2023 that the Site Plan for Freddy’s Waukee is approved subject to remaining staff comments. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Anna Bergman Pierce R. Charles Bottenberg Chris Crone Larry R. Lyon Ben Sinclair PLANNING AND ZONING COMMISSION STAFF REPORT PROJECT: Freddy’s Waukee – Site Plan PREPARED BY: Melissa DeBoer, AICP – Planning Coordinator REPORT DATE: November 8, 2023 MEETING DATE: November 14, 2023 GENERAL INFORMATION Owner/Applicant: MLY Real Estate Inc Engineer: James Rodemyer, PE – Bishop Engineering Request: The applicant is requesting approval of a site plan for a commercial building. Location and Size: Property is generally located west of SE Alice’s Road and south of SE Laurel Street, containing approximately 1.20 acres. Property Address: 440 SE Alice’s Road AREA MAP ABOVE: Aerial of property identifying the proposed site plan (outlined in RED). November 9, 2023 2 of 3 LAND USES AND ZONING Location Existing Land Use Comprehensive Plan Current Zoning Property in Question Vacant – Undeveloped Neighborhood Commercial C-1 / PD-1 (Community and Highway Service Commercial District / Planned Development District) North Vacant – Undeveloped Neighborhood Commercial / Community Commercial C-1 / PD-1 (Community and Highway Service Commercial District / Planned Development District) South Vacant – Undeveloped Neighborhood Commercial C-1 / PD-1 (Community and Highway Service Commercial District / Planned Development District) East Hickman West Industrial Park Neighborhood Commercial M-1 (Light Industrial District) West Future Waukee Towne Center Retail Neighborhood Commercial C-1 / PD-1 (Community and Highway Service Commercial District / Planned Development District) HISTORY The subject property was recently platted as part of Waukee Towne Center Plat 5. PROJECT DESCRIPTION The project includes the construction of a single-story building for a fast-food restaurant with a drive through. The building is 2,880 square feet in area and 23.5 feet in height. The site includes two drive through lanes for ordering and one drive through lane for pick-up. A patio for dining is proposed along the east side of the building. A trash enclosure and small storage shed, that measures just under 148 square feet, is proposed to the west of the building. A monument sign is shown at the northeast corner of the site, along SE Alice’s Road. ACCESS AND PARKING One access will be provided into the site off of the private drive to the west. There will also be shared accesses to the adjacent lots, both to the north and to the south when those lots develop in the future. Pedestrian connections are provided into the site from both the existing trail along SE Alice’s Road and the private sidewalk to the west that will be constructed with this project. A total of 44 parking spaces and 10 queuing spaces are required for the proposed site plan. The total amount of parking proposed is 50 spaces including 3 accessible stalls. They are providing 15 queuing spaces for the drive through. November 9, 2023 3 of 3 UTILITIES This site will be serviced with private utilities that have been extended throughout the overall plat. Storm water detention is provided with the large pond located to the southwest, within the overall Waukee Towne Center development. LANDSCAPING & OPEN SPACE A minimum of 20% of the project area is required to be open space. The total amount of open space proposed is 21.4%. The landscape plan meets the requirements of the Landscape and Open Space Ordinance. ELEVATIONS The elevations of the building are proposed to be constructed mostly of brick, EIFS, storefront system, and Nichiha panels. The trash enclosure and storage shed will be constructed of Nichiha panels and the gate for the trash enclosure will be a composite material. PHOTOMETRIC PLAN A photometric plan for the site lighting has been submitted and complies with the requirements of the Site Plan Ordinance. COMPREHENSIVE PLAN The comprehensive plan classifies the subject property as Neighborhood Commercial. The Neighborhood Commercial classification provides a variety of uses that would serve the surrounding neighborhoods and provide day-to-day goods and services for residents. STAFF RECOMMENDATION The site plan is in general conformance with the Site Plan Ordinance, Comprehensive Plan, and Planned Development. Staff recommends approval of the site plan for Freddy’s Waukee subject to remaining staff comments. FREDDY'S WAUKEE SITE PLAN IOWAONE CALL 1-800-292-8989 www.iowaonecall.com 811 Know what's below. Call before you dig. PROPERTY DESCRIPTION: LOT 2 WAUKEE TOWNE CENTER PLAT 5, A PLAT RECORDED IN DALLAS COUNTY, IOWA ADDRESS: 440 SE ALICE'S RD WAUKEE, IA 50263 OWNER: MLY REAL ESTATE INC ATTN: MIKE YOUNG 1241 PARK PLACE NE SUITE C CEDAR RAPIDS, IA 52402 ZONING: PD- PLANNED DEVELOPMENT DISTRICT C-1- COMMUNITY AND HIGHWAY SERVICE COMMERCIAL DISTRICT SETBACKS: FRONT: 30' REAR: 30' SIDE: 0' OR 30' IF ADJACENT TO "R" DISTRICT PARKING REQUIREMENTS: LAND USE- RESTAURANT (FAST FOOD) 15 SPACES PER 1,000 SF AND 5 QUEUING SPACES PER DRIVE THROUGH LANE REQUIRED PARKING: 15 * 2,880 SF / 1,000 SF= 44 SPACES 5 * 2 LANES= 10 QUEUING SPACES PARKING PROVIDED: 50 SPACES (3 ADA) 15 QUEUING SPACES OPEN SPACE REQUIREMENTS: TOTAL LOT AREA: 52,176 SF (1.20 ACRES) OPEN SPACE REQUIRED = 10,435 SF (20%) OPEN SPACE PROVIDED = 11,176 SF (21.4%) IMPERVIOUS SURFACE = 41,000 SF (78.6%) BENCHMARK: BRASS DISC AT THE NE CORNER OF SECTION 34-79-26 (INTERSECTION OF HICKMAN ROAD AND ALICE'S ROAD) ELEVATION = 1029.33 BUILDING HEIGHT: PROPOSED BUILDING HEIGHT = 23'-7" CONSTRUCTION SCHEDULE: APPROXIMATE CONSTRUCTION SCHEDULE GRADING: LATE FALL TO EARLY WINTER 2023 UTILITIES: LATE FALL TO EARLY WINTER 2023 PAVING: SPRING 2024 LANDSCAPING: SPRING TO SUMMER 2024 VICINITY MAP NOT TO SCALE: COPYRIGHT 2023 BISHOP ENGINEERING. THIS DOCUMENT AND THE INFORMATION CONTAINED MAY NOT BE REPRODUCED OR EXCERPTED WITHOUT THE EXPRESS WRITTEN PERMISSION OF BISHOP ENGINEERING. UNAUTHORIZED COPYING OR DISCLOSURE OF CONSTRUCTION USE ARE PROHIBITED BY COPYRIGHT LAW. CO V E R S H E E T C0.1 SHEET INDEX: C0.1 COVER SHEET C2.1 LAYOUT PLAN C3.1 GRADING PLAN C4.1 UTILITY PLAN C5.1 LANDSCAPE PLAN C6.1 DETAILS SHEET C7.1 SWPPP REFERENCE NUMBER: 35 0 1 1 0 4 t h S t r e e t De s M o i n e s , I o w a 5 0 3 2 2 - 3 8 2 5 Ph o n e : ( 5 1 5 ) 2 7 6 - 0 4 6 7 F a x : ( 5 1 5 ) 2 7 6 - 0 2 1 7 "P l a n n i n g Y o u r S u c c e s s f u l D e v e l o p m e n t " Bi s h o p E n g i n e e r i n g Ci v i l E n g i n e e r i n g & L a n d S u r v e y i n g E s t a b l i s h e d 1 9 5 9 DRAWN BY: CHECKED BY: REVISION DATE: PROJECT NUMBER: SHEET NUMBER: FR E D D Y ' S S I T E P L A N WA U K E E E , I O W A CC 1ST CITY SET 10/10/23 2ND CITY SET 10/24/23 3RD CITY SET 11/7/23 230336 PR E L I M I N A R Y - N O T F O R C O N S T R U C T I O N L: \ L A N D P R O J E C T S 2 0 2 3 \ 2 3 0 3 3 6 F R E D D Y ' S W A U K E E \ D W G \ C 0 C O V E R . D W G 11 / 7 / 2 0 2 3 1 1 : 3 0 : 4 7 A M UTILITY NOTE: THE LOCATION OF THE UTILITIES INDICATED ON THE PLANS HAVE BEEN TAKEN FROM THE FIELD SURVEY, EXISTING PUBLIC RECORDS, AND PLANS PROVIDED BY OTHERS. SURFACE UTILITY LOCATIONS HAVE BEEN FIELD LOCATED BY BISHOP ENGINEERING, UNLESS OTHERWISE NOTED. ALL UNDERGROUND UTILITY LOCATIONS ARE APPROXIMATE LOCATIONS ONLY. BISHOP ENGINEERING DOES NOT GUARANTEE THE UNDERGROUND LOCATION OF ANY UTILITIES SHOWN. IT SHALL BE THE DUTY OF THE CONTRACTOR TO DETERMINE THE LOCATION AND DEPTH OF ANY UNDERGROUND UTILITIES SHOWN AND IF ANY ADDITIONAL UTILITIES, OTHER THAN THOSE SHOWN ON THE PLANS, MAY BE PRESENT. A REQUEST WAS MADE TO IOWA ONE CALL FOR UTILITY PROVIDERS TO VERIFY, LOCATE, AND MARK THEIR UTILITIES IN THE FIELD.C0.1 - C7.1 ABBREVIATIONS: AC ACRES ASPH ASPHALT BK BOOK CONC CONCRETE D DEEDED DISTANCE EX EXISTING ENCL ENCLOSURE FF FINISHED FLOOR FL FLOW LINE FRAC FRACTIONAL M MEASURED DISTANCE MH MANHOLE OPC ORANGE PLASTIC CAP P PLATTED DISTANCE PG PAGE POB POINT OF BEGINNING POC POINT OF COMMENCEMENT PRA PREVIOUSLY RECORDED AS PUE PUBLIC UTILITY EASEMENT ROW RIGHT OF WAY RPC RED PLASTIC CAP SF SQUARE FEET SAN SANITARY TYP TYPICAL YPC YELLOW PLASTIC CAP N NORTH S SOUTH E EAST W WEST ELECTRIC VAULT TRANSFORMER POLE TRANSFORMER POLE LIGHT POLE ELECTRIC JUNCTION BOX ELECTRIC PANEL TRANSFORMER GROUND LIGHT GUY WIRE ELECTRIC HANDHOLE GAS METER GAS VALVE AIR CONDITIONING UNIT TELEPHONE RISER TELEPHONE VAULT TELEPHONE MANHOLE TRAFFIC SIGNAL MANHOLE FIBER OPTIC MANHOLE FIBER OPTIC RISER FIBER OPTIC VAULT CABLE TV RISER SIGN BOLLARDS 7 DENOTES NUMBER OF PARKING STALLS PROPERTY CORNER - FOUND AS NOTED PROPERTY CORNER- PLACED 5/8" IRON ROD WITH YELLOW PLASTIC CAP ID # XXXXX OR AS NOTED SECTION CORNER - FOUND AS NOTED SITE CONTROL POINT - MONUMENT AS NOTED ELEC EJ EP GM GV A/C T TEL T TS FO F/O TV F/O SAN SANITARY SEWER ST STORM SEWER W WATER LINE G GAS LINE U/E UNDERGROUND ELECTRIC O/E OVERHEAD ELECTRIC TELE TELEPHONE LINE F/O FIBER OPTIC CATV CABLE TV STORM MANHOLE CURB INTAKE SURFACE INTAKE FLARED END SECTION ROOF DRAIN DOWNSPOUT SANITARY MANHOLE CLEANOUT FIRE HYDRANT SPRINKLER IRRIGATION CONTROL VALVE WATER MANHOLE WELL WATER VALVE WATER SHUT OFF YARD HYDRANT FLAGPOLE ELECTRIC MANHOLE ELECTRIC METER ELECTRIC RISER D S CO H Y D I CV W WS O YA DR E EM E W WV LEGEND SITE SE A L I C E R O A D SE LAUREL ST WETLAND NOTES: 1.A WETLAND INVESTIGATION WAS COMPLETED ON THE PROJECT SITE BY EMMONS AND OLIVIER RESOURCES, INC. FOUR SMALL AGRICULTURAL WETLANDS WERE FOUND. THE REPORT WAS SUBMITTED TO THE ARMY CORPS OF ENGINEERS, WHICH DETERMINED THAT THE WETLANDS ARE NOT JURISDICTIONAL WATERS OF THE UNITED STATES, AND DOES NOT REQUIRED A SECTION 404 PERMIT. STAKING NOTES: 1.CONTRACTOR IS REQUIRED TO HAVE ALL STAKING DONE UNDER THE SUPERVISION OF A LICENSED LAND SURVEYOR AND IN COORDINATION WITH THE PROJECT ENGINEER. 2.CONTRACTOR IS REQUIRED TO HAVE ALL STAKING DONE DIRECTLY UNDER THE GENERAL CONTRACTOR BY A SINGLE COMPANY. 3.STAKING DOES NOT RELIEVE CONTRACTOR OF ULTIMATE RESPONSIBILITY TO CONSTRUCT THE PROJECT PER PLAN. EARTHWORK BALANCE NOTES: 1.EXISTING CONTOURS SHOWN ON PLANS ARE THE PROPOSED CONTOURS FROM THE WAUKEE TOWNE CENTER PLAT 3 CONSTRUCTION PLANS. 2.SOIL IMPORT OR EXPORT ON THIS PROJECT SHALL BE CONSIDERED INCIDENTAL AND WILL NOT BE MEASURED OR PAID FOR SEPARATELY. CONTRACTOR RESPONSIBLE FOR MAKING THE SITE EARTHWORK BALANCE. NO CHANGE ORDERS WILL BE ISSUED AS IT RELATES TO EARTHWORK QUANTITIES. THIS INCLUDES BUT IS NOT LIMITED TO TOPSOIL, POOR SOILS AND STRUCTURAL FILL NECESSARY TO MEET PROJECT PLANS AND SPECIFICATIONS. STORM & SANITARY TELEVISING NOTES: 1.CONTRACTOR IS REQUIRED TO TELEVISE ALL SANITARY AND STORM SEWER SYSTEM PRIOR TO PAVING OPERATIONS. 2.CONTRACTOR SHALL SEND VIDEO INSPECTION TO THE ENGINEER FOR APPROVAL PRIOR TO PAVING. 3.CONTRACTOR SHALL PROVIDE COPIES OF THE REPORTS AND VIDEOS TO THE WAUKEE ENGINEERING DEPARTMENT FOR APPROVAL PRIOR TO PAVING. UTILITY CONFLICT NOTES: 1.UTILITY CONFLICTS MAY EXIST ACROSS THE SITE WITH NEW UTILITIES, GRADING, PAVING ETC. MOST UTILITY CONFLICTS HAVE BEEN CALLED OUT FOR CONTRACTOR CONVENIENCE. 2.CONTRACTOR IS RESPONSIBLE FOR ALL UTILITY CONFLICTS THAT ARE EITHER CALLED OUT ON THE PLANS OR THAT CAN BE SEEN ON THE PLANS BETWEEN AN EXISTING UTILITY AND PROPOSED CONSTRUCTION. 3.CONTRACTOR SHALL USE O-RING GASKET JOINTS FOR STORM SEWER AND SANITARY SEWER AT CROSSINGS WITH WATER WHERE STORM OR SANITARY SEWER CROSSES OVER OR LESS THAN 18 INCHES BELOW WATER. O-RING GASKET JOINTS SHALL BE EXTENDED UNTIL WATER AND SEWER ARE AT LEAST 10 FEET APART. ALL O-RING GASKET JOINTS SHALL BE CONSIDERED INCIDENTAL TO BID. IF N-12 PIPE IS USED FOR STORM SEWER, CONTRACTOR SHALL USE WATER-TIGHT N-12 PIPE, CENTERED ON THE CROSSING. 4.FOR ALL CRITICAL CROSSINGS WITH EXISTING UTILITIES, THE ELEVATION OF THE EXISTING UTILITY SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. NOTIFY BISHOP ENGINEERING PRIOR TO CONSTRUCTION IF A CONFLICT EXISTS. GENERAL NOTES: 1.ALL WORK SHALL BE DONE IN ACCORDANCE WITH 2023 WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND SUDAS 2023 STANDARD SPECIFICATIONS. THE CITY OF WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT MUST BE NOTIFIED BY ALL CONTRACTORS 48 HOURS PRIOR TO COMMENCING WORK AND PRIOR TO ANY WEEKEND OR HOLIDAY WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT 1 WEEK PRIOR TO ANY PLANNED WORK TO SCHEDULE A PRE-CONSTRUCTION MEETING. 2.IN EVENT OF A DISCREPANCY BETWEEN THE QUANTITY ESTIMATES AND THE DETAILED PLANS, THE DETAILED PLANS SHALL GOVERN. 3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION OF ALL UTILITIES. ANY DAMAGE TO SAID UTILITIES SHALL BE REPAIRED AT THE CONTRACTORS EXPENSE. 4.ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE CURRENT O.S.H.A. CODES AND STANDARDS. NOTHING INDICATED ON THESE PLANS SHALL RELIEVE THE CONTRACTOR FROM COMPLYING WITH THE APPROPRIATE SAFETY REGULATIONS. 5.ALL NECESSARY CONSTRUCTION SIGNS, BARRICADES AND OTHER TRAFFIC CONTROL DEVICES REQUIRED DURING CONSTRUCTION WILL BE FURNISHED BY THE CONTRACTOR. SIGNS, BARRICADES AND OTHER TRAFFIC CONTROL DEVICES MUST BE IN CONFORMANCE WITH THE "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS" AND CITY OF WAUKEE REQUIREMENTS. 6.BISHOP ENGINEERING SHALL NOT BE LIABLE FOR ANY INJURIES THAT HAPPEN ON SITE. THIS SHALL INCLUDE BUT NOT BE LIMITED TO TRENCH COLLAPSES FROM VARYING SOIL CONDITIONS OR INJURIES CAUSED BY UNDERGROUND UTILITIES INCLUDING UTILITIES THAT ARE NOT SHOWN ON PLAN. 7.THE CONTRACTOR IS LIABLE FOR ALL DAMAGES TO PUBLIC OR PRIVATE PROPERTY CAUSED BY THEIR ACTION OR INACTION IN PROVIDING FOR STORM WATER FLOW DURING CONSTRUCTION. DO NOT RESTRICT FLOWS IN EXISTING DRAINAGE CHANNELS, STORM SEWER, OR FACILITIES. 8.THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER A SCHEDULE FOR PERFORMANCE OF WORK ITEMS. THIS SCHEDULE SHALL BE PROVIDED BY THE CONTRACTOR AT THE PROJECT PRECONSTRUCTION CONFERENCE. NO WORK SHALL BEGIN UNTIL A SCHEDULE HAS BEEN SUBMITTED AND ACCEPTED. THE CONTRACTOR SHALL THEN PERFORM WORK TO CONFORM TO THE ACCEPTED SCHEDULE. 9.LABORATORY TESTS SHALL BE PERFORMED BY THE OWNER UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL PROVIDE SAMPLES OF MATERIAL REQUIRED FOR LABORATORY TESTS AND TESTING IN ACCORDANCE WITH THE URBAN STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS. 10.THE CONTRACTOR SHALL PROTECT ALL STRUCTURES NOT SHOWN AS REMOVALS ON THE PLANS. 11.THE CONTRACTOR SHALL OBTAIN ANY AND ALL NECESSARY PERMITS PRIOR TO ANY CONSTRUCTION. CONTRACTOR SHALL WORK WITH OWNER OR OWNERS REPRESENTATIVE ON ALL REQUIRED STORM WATER DISCHARGE PERMITS FROM THE IOWA DEPARTMENT OF NATURAL RESOURCES AND THE CITY OF WAUKEE. 12.GRADING AND EROSION CONTROL SHALL BE DONE IN ACCORDANCE WITH THE APPROVED GRADING PLAN, SWPPP, NPDES DOCUMENTS, AND IOWA DEPARTMENT OF NATURAL RESOURCES REQUIREMENTS. 13.THE CONTRACTOR SHALL PICK UP ANY DEBRIS SPILLED ONTO THE ADJACENT RIGHT OF WAY OR ABUTTING PROPERTIES AS THE RESULT OF CONSTRUCTION, AT THE END OF EACH WORK DAY AND PRIOR TO A RAIN EVENT. 14.THE CONTRACTOR IS RESPONSIBLE FOR THE PROMPT REMOVAL OF ALL MUD THAT HAS BEEN TRACKED OR WASHED UNTO ADJACENT PROPERTY OR RIGHT OF WAY UNTIL SUCH TIME THAT PERMANENT VEGETATION HAS BEEN ESTABLISHED. 15.DISPOSE OF ALL EXCESS MATERIALS AND TRASH IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL REQUIREMENTS. PROVIDE WASTE AREAS OR DISPOSAL SITES FOR EXCESS MATERIALS NOT DESIRABLE FOR INCORPORATION INTO THE PROJECT. 16.ANY PROPOSED CHANGES TO THE APPROVED PLAN SET DURING CONSTRUCTION MUST RECEIVE WRITTEN APPROVAL FROM THE CITY OF WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT AND DESIGN ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY CHANGES MADE DURING CONSTRUCTION THAT HAVE NOT RECEIVED WRITTEN APPROVAL FROM THE CITY OF WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT. 17.CONTRACTOR SHALL PROVIDE THE CITY OF WAUKEE ENGINEERING DEPARTMENT WITH A LIST OF QUANTITIES FOR SCHEDULING INSPECTION PURPOSES. PAVING NOTES: 1.THE PAVING/ GRADING CONTRACTOR SHALL BACKFILL THE PAVING SLAB AND FINE GRADE THE RIGHT OF WAY AS SOON AFTER THE PAVING AS POSSIBLE. ALL AREAS SHALL BE SEEDED IN ACCORDANCE WITH CITY OF WAUKEE 2023 STANDARD SPECIFICATIONS AND THE CURRENT VERSION OF SUDAS. 2.SUBGRADE PREPARATION AND PAVEMENTS WILL BE CONSTRUCTED FOLLOWING RECOMMENDATIONS IN THE SOILS REPORT. APPROVED SOILS ENGINEER MUST SIGN OFF ON SUBASE PRIOR TO ANY PAVEMENT BEING PLACED. 3.SEE DETAILS FOR ALL PAVEMENT THICKNESS. 4.DETECTABLE WARNING PANELS CALLED OUT ON PLANS SHALL BE PER A.D.A. REGULATIONS. PANEL TYPE & COLOR TO BE CAST IRON WITH NATURAL FINISH. 5.ALL WALKS, PARKING LOTS, HANDICAP PARKING, RAMPS, ETC. SHALL COMPLY WITH ALL A.D.A. AND CITY CODES. HANDICAP PARKING SIGNAGE IS REQUIRED FOR ALL HANDICAP STALLS AND SHALL BE CONSIDERED INCIDENTAL. IN EVENT OF A DISCREPANCY BETWEEN THE PLANS AND THE A.D.A./CITY CODES THE A.D.A./CITY CODES SHALL GOVERN. CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING A.D.A. CODES ARE MET. 6.ALL PAVEMENT REPLACEMENT SHALL COMPLY WITH THE WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS. UTILITY NOTES: 1.QUANTITY CALLOUTS ON PIPE LENGTHS ARE APPROXIMATE AND SHOULD BE USED FOR REFERENCE ONLY. 2.THE CONTRACTOR SHALL COORDINATE THE ADJUSTMENT OF ANY AND ALL EXISTING AND PROPOSED UTILITIES TO PROPOSED GRADES. EXISTING UTILITIES SHALL BE RAISED OR LOWERED IN ACCORDANCE WITH THE UTILITY OWNER REQUIREMENTS. ANY NECESSARY ADJUSTMENTS SHALL BE CONSIDERED INCIDENTAL TO CONSTRUCTION. 3.ALL PROPOSED RCP STORM SEWER PIPE JOINTS SHALL BE FABRIC WRAPPED AND THE LAST 3 PIPE SECTIONS ON THE APRON SHALL BE TIED WITH RF-14 TYPE II CONNECTORS. ALL APRONS SHALL HAVE A STANDARD FOOTING AND TRASH GUARD. ALL FLARED END SECTIONS SHALL HAVE A 3' WIDE CLAY WATERSTOP (SUDAS SW-105). 4.ALL RIP RAP CALLED OUT ON PLANS SHALL BE UNDERLAIN WITH ENGINEERING FABRIC. 5.ALL STRUCTURE SIZES CALLED OUT ON PLANS ARE MINIMUM INSIDE WALL DIMENSIONS. 6.ALL STRUCTURES CALLED OUT AS "MODIFIED" OR "SPECIAL" SHALL BE ENGINEERED BY THE PRECASTER TO ENSURE STRUCTURE STABILITY. MODIFICATIONS INCLUDE ADDITIONAL WALL LENGTH TO ACCOUNT FOR LARGE PIPE DIAMETERS AND ADDITIONAL WALL WIDTH & BASE DEPTH TO ACCOUNT FOR DEEPER STRUCTURES. ANY AND ALL MODIFICATIONS TO STANDARD STRUCTURES SHALL BE CONSIDERED INCIDENTAL TO BID. 7.SANITARY SERVICES SHALL MAINTAIN 18" OF VERTICAL SEPARATION FROM THE WATERMAIN WITH 18" OF COMPACTED LOW PERMEABILITY SOIL BETWEEN THE UTILITIES WITHIN 10' OF THE CROSSING. 8.MANDREL AND PRESSURE TESTS SHALL BE REQUIRED FOR ALL PROPOSED SANITARY LINES, ALL SANITARY MANHOLES SHALL BE VACUUM TESTED. ALL SANITARY AND STORM LINES SHALL BE CLEANED AND TELEVISED PRIOR TO PAVING. THE CITY SHALL WITNESS ALL CLEANING AND TELEVISING, COPIES OF THE REPORTS AND VIDEOS SHALL BE PROVIDED TO THE CITY OF WAUKEE ENGINEERING DEPARTMENT. 9.ALL UTILITIES SHALL BE TESTED TO CITY OF WAUKEE STANDARDS AND THE CITY OF WAUKEE ENGINEERING DEPARTMENT SHALL WITNESS ALL TESTING. 10.ALL WATER LINE MATERIAL SHALL BE C-900 UNLESS NOTED OTHERWISE ON PLANS. SIZE OF WATERMAIN AS SHOWN ON PLANS. 11.THRUST BLOCKS SHALL BE INSTALLED AS REQUIRED AND SHALL BE CONSIDERED INCIDENTAL TO WATERMAIN CONSTRUCTION. 12.PROPOSED WATERMAIN SHALL BE PRESSURE TESTED, BACTERIA TESTED AND CHLORINATED. THE FILLING OF THE WATER MAIN SHALL BE DONE BY THE CITY OF WAUKEE. 13.TRACER WIRE SHALL BE ADDED TO ALL WATER MAIN, AND BROUGHT TO THE SURFACE AT EVERY HYDRANT. 14.ALL HYDRANTS WILL IMMEDIATELY BE COVERED WITH A BLACK PLASTIC BAG (OR EQUIVALENT) ONCE THE HYDRANT IS INSTALLED. THE CITY OF WAUKEE WILL NOTIFY THE CONTRACTOR WHEN THE BAGS CAN BE REMOVED. 15.THE MINIMUM HYDRANT LEAD SHALL BE 3.5 FEET. 16.FIRE HYDRANT ASSEMBLY SHALL INCLUDE TEE, BRANCH, VALVE & HYDRANT AND A 5" STORZ CONNECTION. 17.ANY AND ALL HYDRANT AND VALVE EXTENSIONS, TOGETHER WITH VERTICAL BENDS, SHALL BE CONSIDERED INCIDENTAL TO WATER MAIN CONSTRUCTION. NO ADDITIONAL PAYMENT WILL BE PROVIDED FOR INCIDENTAL ITEMS. 18.ALL UTILITY CONNECTIONS TO EXISTING UTILITIES SHALL BE COORDINATED WITH THE CITY OF WAUKEE ENGINEERING DEPARTMENT. SWPPP NOTES: 1.STORM WATER POLLUTION PREVENTION PLAN HAS BEEN PREPARED BY BISHOP ENGINEERING. CONTACT JAMES RODEMYER (515-276-0467) FOR A COPY OF THE SWPPP. 2.NPDES PERMIT AUTHORIZATION NUMBER: TBD 3.THIS PROJECT INCLUDES SAWCUTTING OR CONCRETE GRINDING SO PROTECTION OF STORM SEWERS AND DRAINAGE WAYS WILL NEED TO BE PROVIDED FROM SLURRY FROM THE CONCRETE OPERATIONS. SEE SWPPP SHEET AND NARRATIVE FOR ADDITIONAL DETAILS. MONUMENT AND BUILDING SIGNAGE: 1.ALL MONUMENT SIGNS ARE SUBJECT TO REVIEW BY THE CITY OF WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT 2.CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL SIGN PERMITS PRIOR TO INSTALLATION OF ANY GROUND OR BUILDING SIGNAGE AND SHALL ENSURE COMPLIANCE WITH ALL CITY REGULATIONS. SECURITY NOTES: 1.CONTRACTOR RESPONSIBLE FOR SECURITY OF THE SITE. 2.TEMPORARY FENCES OR ANY OTHER SECURITY MEASURES ARE THE RESPONSIBILITY OF THE CONTRACTOR. 3.NO SECURITY MEASURES WILL BE ELIGIBLE FOR A CHANGE ORDER AND MUST BE INCLUDED IN THE BASE BID. FIRE DEPARTMENT ACCESS NOTES: 1.AN APPROVED FIRE APPARATUS ACCESS ROAD SHALL BE PROVIDED FOR ALL BUILDINGS, OR PORTIONS OF A BUILDING AS SOON AS VERTICAL CONSTRUCTION OF THE BUILDING COMMENCES. 2.FIRE APPARATUS ACCESS ROAD SHALL COMPLY WITH THE REQUIREMENTS OF 2015 IFC 503.2 AND SHALL EXTEND TO WITHIN 150 FEET OF ALL EXTERIOR PORTIONS OF THE BUILDING AS MEASURED BY AN APPROVED ROUTE AROUND THE EXTERIOR OF THE BUILDING. 3.FIRE APPARATUS TRAIL (AS SHOWN ON PLANS) SHALL BE INSTALLED PRIOR TO BUILDING GOING VERTICAL. IF PAVEMENT IS NOT PLANNED TO BE INSTALLED PRIOR TO THE BUILDING GOING VERTICAL, THAN TEMPORARY ROCK ACCESS SHALL BE PROVIDED AROUND THE BUILDING AND CONNECTED TO THE ROCK CONSTRUCTION ENTRANCE. 4.ANY TEMPORARY ROCK USED FOR THE FIRE DEPARTMENT ACCESS ROUTE SHALL BE REMOVED FROM THE SITE PRIOR TO TOPSOIL SPREADING AND SEEDING. SEE TOPSOIL NOTES ON COVER SHEET AND GRADING PLAN. 5.ANY AND ALL FIRE APPARATUS ACCESS ROAD WORK NECESSARY TO COMPLY WITH WAUKEE FIRE DEPARTMENT REQUIREMENTS SHALL BE CONSIDERED INCIDENTAL TO BID. PAVEMENT SAWCUT NOTES: 1.CONTRACTOR SHALL FOLLOW JOINTING SHOWN ON PLANS. IF CONTRACTOR WANTS TO DEVIATE FROM JOINTING SHOWN, CONTRACTOR SHALL PROVIDE SAWCUT JOINTING PLAN TO JOEL JACKSON, BISHOP ENGINEERING (515-276-0467 OR JJACKSON@BISHOPENGR.COM) PRIOR TO ANY CONCRETE PAVEMENT INSTALLATION. 2.PAVEMENT MAY BE REQUIRED TO BE REMOVED AND REPLACED IF PLACED NOT IN COMPLIANCE WITH JOINTING PLAN. 3.LONGITUDINAL JOINTS IN DRIVE LANES & THE OUTER MOST JOINT OF ALL PARKING AREAS SHALL BE SUDAS TYPE 'L-1' OR 'L-2' JOINTS AND HAVE STEEL. INTERIOR PARKING LOT JOINTS, OTHER THAN THE OUTER MOST JOINT, DO NOT NEED STEEL AND SHALL BE SUDAS TYPE 'B' JOINTS. 4.TYPICAL LONGITUDINAL JOINTS SHALL BE PLACED IN THE CENTER OF ALL DRIVE AISLES AND AT THE END OF ALL PARKING STALLS. 5.ALL TRANSVERSE JOINTS SHALL BE SUDAS TYPE 'C' OR TYPE 'DW' JOINTS WITH STEEL IN THE CASE OF A DAY'S WORK JOINT. 14 12 PR O P O S E D T R A S H EN C L O S U R E 9 PR I V A T E D R I V E SE A L I C E ' S R O A D 15 PROPOSED 30.5'X85.85' BUILDING 2,880 SF FFE= 1047.50 D SSANSANSAN H Y D W6"W6" W2" GM G G CO W6" 26°0'0" 30°0'0" 33°0'0" 45°0'0" EM 17' 17' BOLLARD W/ HC SIGN (SEE DETAIL 8/C6.1) TYPE 2 PAVEMENT 9' 7' 24 ' 12 ' 5' 8'9'9'5'9' 24' 24' 24 ' 13.31' 110.34' 17 ' 12 ' 5' 24' 11 ' 18 ' 6. 3 8 ' 24' 24' 5' 17 ' 5'12'32.12' 5' 5' SUDAS TYPE A DRIVEWAY CONNECTION TYPE 1 PAVEMENT TYPE 1 PAVEMENT TYPE 1 PAVEMENT TY P E 1 P A V E M E N T TY P E 1 P A V E M E N T TYPE 1 PAVEMENT PAINTED ARROW, TYP PAINTED ARROW, TYP R5' R1 0 ' R5'R 5 ' R10 ' R 5 ' R10' R5' R 5 ' R10' R 1 0 ' R3 2 ' R3 2 'R1.5' R 2 0 ' R2 0 ' R1 . 5 ' R20 ' R32' R20 ' R1.5' R5' R 5 'R5' R 1 0 ' R 3 ' ADA RAMP & LANDING ADA RAMP & LANDING ADA RAMP & LANDING ADA RAMP & LANDING W/ BEAM CURB (SEE DETAIL 6/C6.1) 5" PCC TURNED DOWN WALK (SEE DETAIL 3/C6.1) 5" P C C W A L K 5" P C C W A L K 5" P C C W A L K 6' 5" PCC TURNED DOWN WALK (SEE DETAIL 3/C6.1) BOLLARD W/ VAN ACCESSIBLE HC SIGN (SEE DETAIL 8/C6.1) 6" WIDE DRIVE THRU STRIPING 5" P C C W A L K FLAGPOLE 1. 2 ' 1. 6 ' 7' MENUBOARD, TYP ORDER POINT WITH DELUXE CANOPY, TYP DOUBLE CLEARANCE BAR PRESELL BOARD, TYP 12 ' R 5 ' 11.01' 1. 7 ' R10' 24' R 1 8 ' 2' 16' MONUMENT SIGN LOCATION WV WV R2 0 ' BOLLARD, TYP (SEE DETAIL 14/C6.1) II II II 36" TALL DECORATIVE METAL FENCE 2 3 EX 20' PRIVATE WATER MAIN EASEMENT BK 2023, PG 10323 EX 30' PRIVATE SANITARY SEWER EASEMENT BK 2023, PG 10325 EX 25' PRIVATE STORM SEWER EASEMENT BK 2023, PG 10325 10' PUE BK 2023, PG 10317 EX 25' ELECTRICAL TRANSMISSTION LINE EASEMENT BK 2017, PG 23500 30 ' B U I L D I N G S E T B A C K L I N E EX 40' INGRESS EGRESS EASEMENT BK 2023, PG 10327 EX PRIVATE STORM SEWER EASEMENT BK 2023 PG 14105 LA Y O U T P L A N C2.1 REFERENCE NUMBER: 35 0 1 1 0 4 t h S t r e e t De s M o i n e s , I o w a 5 0 3 2 2 - 3 8 2 5 Ph o n e : ( 5 1 5 ) 2 7 6 - 0 4 6 7 F a x : ( 5 1 5 ) 2 7 6 - 0 2 1 7 "P l a n n i n g Y o u r S u c c e s s f u l D e v e l o p m e n t " Bi s h o p E n g i n e e r i n g Ci v i l E n g i n e e r i n g & L a n d S u r v e y i n g E s t a b l i s h e d 1 9 5 9 DRAWN BY: CHECKED BY: REVISION DATE: PROJECT NUMBER: SHEET NUMBER: FR E D D Y ' S S I T E P L A N WA U K E E E , I O W A CC 1ST CITY SET 10/10/23 2ND CITY SET 10/24/23 3RD CITY SET 11/7/23 230336 PR E L I M I N A R Y - N O T F O R C O N S T R U C T I O N L: \ L A N D P R O J E C T S 2 0 2 3 \ 2 3 0 3 3 6 F R E D D Y ' S W A U K E E \ D W G \ C 2 L A Y O U T . D W G 11 / 7 / 2 0 2 3 1 1 : 3 0 : 5 6 A M GRAPHIC SCALE 020 10 20 40 PR O P O S E D T R A S H EN C L O S U R E PR I V A T E D R I V E SE A L I C E ' S R O A D PROPOSED 30.5'X85.85' BUILDING 2,880 SF FFE= 1047.50 D SSANSANSAN H Y D W6"W6" W2" GM G G 2.0% 4.7% 2.6 % 3.7% 1.2% 4: 1 3 . 0 % 3.3 % 2.6% 2.4 % TAPER OUT CURB TAPER OUT CURB TAPER OUT CURB TAPER OUT CURB TAPER OUT CURB 3: 1 3: 1 5 : 1 2.4 % 6 . 2 % 4. 4 % 7. 5 % 2. 8 % 2.8% 4.9%4.1% 4.4% 6.0 % CO W6" 100-YR PONDING ELEV=1045.78 100-YR PONDING ELEV=1045.51 100-YR PONDING ELEV=1044.54 100-YR PONDING ELEV=1045.90 EM 1.0% 1.5% 1044.52± EX 104 0 1045 1041 1042 1043 1044 1046 1047 1 0 4 5 10 4 5 1 0 4 6 1046 1046 1046 1047 1047 1047 1047 1046 10 4 7 104 6 10 4 6 10 4 6 1 0 4 5 1045 1050 1043 1044 1046 1047 1048 1049 10 4 6 1 0 4 6 10 4 5 0.5% 1045.62± EX 1044.82± EX 100-YR PONDING ELEV=1041.64 OVERTOPPING AT NW CORNER OF LOT 1 ELEV=1044.35 WV WV 0. 5 % 0. 9 % 1. 5 % 1.5% 1.5% 1. 0 % 1. 0 % 4.7% 4.7%1. 5 % 1.5% 1. 0 % 1. 5 % 1. 0 % 0.5% 1.5% 1. 0 % 1. 0 % 1.5% 6. 3 % 6. 3 % 6. 2 % 6. 2 % 1.5% 0. 5 % 0. 5 % 1.5% 1.5% 3.1% 2.4%1. 0 % 0. 6 % 2.6% 1. 5 % 1. 5 % 1. 5 % 1. 5 % 1.0%1.0%1.0%0.0% 1. 3 % 1. 5 % 1. 5 % 1. 5 % 1. 5 % 5.5%0.0%0.0% 1. 5 % 1. 5 % 5.9% 1. 5 % 1.5%1. 5 % 2. 5 % 0. 0 % 1.5% 0. 0 % 1. 5 % 1.5% 1.0% 1. 5 % 1. 5 % 1. 5 % 1. 5 % 1.0% 1.5% 1.5%3.4% 1.0% 1.0% 0. 6 % 0. 5 % 1. 0 % 1. 0 % 1.5% 1.5% 1047.50 1046.68T/C 1046.18G 1046.60T/C 1046.10G1046.48T/C 1045.98G 1046.00T/C 1045.50G 1046.81T/C 1046.31G 1046.95T/C 1046.45G 1047.00T/C 1046.50G 1046.27T/C 1045.77G 1045.64T/C 1045.14G 1045.32T/C 1044.82G 1045.46T/C 1044.96G 1045.68T/C 1045.18G 1045.77T/C 1045.27G 1045.55T/C 1045.05G 1045.94T/C 1045.44G 1046.11T/C 1045.61G 1046.43T/C 1045.93G 1046.23T/C 1045.73G 1047.36T/C 1046.86G1047.14T/C 1046.64G 1046.75G 1047.25T/C 1046.75G 1046.75G 1046.45T/C 1045.95G 1046.53T/C 1046.03G 1047.40T/C 1046.90G 1047.40T/C 1046.90G 1047.30 1046.93T/C 1046.43G 1046.80T/C 1046.30G 1046.74T/C 1046.24G 1046.62T/C 1046.12G 1046.43T/C 1045.93G 1046.54T/C 1046.04G 1047.22T/C 1046.72G 1046.60T/C 1046.10G 1046.20T/C 1045.70G 1046.06T/C 1045.56G 1045.88T/C 1045.38G1045.98T/C 1045.48G 1045.85T/C 1045.35G 1045.64T/C 1045.14G 1046.31T/C 1045.81G 1044.75T/C 1044.25G 1046.11T/C 1045.61G 1046.55T/C 1046.05G 1046.66T/C 1046.16G 1046.56T/C 1046.06G 1046.73T/C 1046.23G 1046.91T/C 1046.41G 1046.59T/C 1046.09G OVERTOPPING 1046.83T/C 1046.33G 1046.93T/C 1046.43G 1046.43T/C 1045.93G 1046.49T/C 1045.99G 1047.10T/C 1046.60G 1047.05T/C 1046.55G 1047.08T/C 1046.58G 1045.95G 1046.05G 1047.13T/C 1046.63G 1046.77T/C 1046.27G 1047.021046.93 1046.50 1046.50T/C 1046.00G 1046.55T/C 1046.05G1046.55 1046.25T/C 1045.75G 1047.40T/C 1046.90G 1046.98T/C 1046.48G 1047.13T/C 1046.63G 1046.81G 1047.36 1047.36 1047.50 1047.30 1046.71G 1046.78G 1046.36 1046.90 1047.40T/C 1046.90G 1047.50T/C 1047.00G 1047.45 1047.24T/C 1046.74G 1046.80T/C 1046.30G 1046.41 1046.46 1045.55 1045.68 1045.77 1046.65T/C 1046.15G 1045.75T/C 1045.25G 1046.92T/C 1046.42G 1047.50 1047.50 1047.30 1046.90 1047.50 1047.50 1047.50 1046.88 1046.88 1045.73±EX 1045.64±EX 1047.36T/C 1046.86G 1045.60 1045.64 1045.69 1047.50T/C 1047.00G 1046.55T/C±EX 1046.29T/C 1045.79G 1045.50T/C 1045.00G 1045.34T/C 1044.84G 1044.57G 1044.52G 1044.89± EX OVERTOPPING 1044.86± EX 1046.38T/C 1045.88G 1045.95T/C 1045.45G 1046.58T/C 1046.08G 1046.97T/C 1046.47G 1047.02T/C 1046.52G 1046.69T/C 1046.19G 1046.69T/C 1046.19G 1047.01T/C 1046.51G 1047.50 1047.40T/C 1046.90G 1047.50 1047.50T/C 1047.00G 1047.50T/C 1047.00G1047.50 1047.40T/C 1046.90G 1047.40T/C 1046.90G 1046.70G 1046.69G 1046.75T/C 1046.25G 1046.53T/C 1046.03G1046.60T/C 1046.10G 1046.831046.76G 1046.62G 1046.71G 1046.63G 1046.37 1046.37 1046.45 1047.13 1047.50 1046.37T/C 1045.87G 1046.39 1047.11T/C 1046.61G 1046.12 1046.69 1046.75 1046.62T/C 1046.12G 1046.67T/C 1046.17G 1039.22 1046.50 OVERTOPPING 1046.48 OVERTOPPING 1047.29T/C 1046.79G 1046.66T/C 1046.16G 1045.54 1044.91 1045.05 1046.22 1046.56 1046.50T/C 1046.00G 1045.10 1045.15 3.5% 3.5%7.1% 7.1%2.0% 0.4% 1.0% 1.0% 1046.22 1046.17 1. 0 % 2.4% 2.2% 2. 7 % 0. 3 % 1.0% 0.8%1.0% 1.0% 1.0% 0.2% 1. 0 % 1.2%0.0%5.9%0.0%5.4%0.0%0.0%1.1%4.5% 1.5% 0. 6 % 0. 6 % 1.5% 1. 6 % 1. 0 % 4.5% II II II 1.1% 1.1% 1. 3 % 2 3 1052 1050 1045 1043 1045 1047 1047 1045 1043 1043 1045 1050 1048 1049 10 4 0 10 4 5 1 0 5 0 1052 1050 1045 1044 1045 1044 1046 1047 1045 1042 1042 1045 1 0 4 5 1 0 4 4 10 4 5 10 4 4 10 4 5 1 0 4 5 10 4 6 1 0 4 6 10 4 1 10 4 2 1 0 4 3 EX 20' PRIVATE WATER MAIN EASEMENT BK 2023, PG 10323 EX 30' PRIVATE SANITARY SEWER EASEMENT BK 2023, PG 10325 EX 25' PRIVATE STORM SEWER EASEMENT BK 2023, PG 10325 10' PUE BK 2023, PG 10317 EX 25' ELECTRICAL TRANSMISSTION LINE EASEMENT BK 2017, PG 23500 30 ' B U I L D I N G S E T B A C K L I N E EX 40' INGRESS EGRESS EASEMENT BK 2023, PG 10327 EX PRIVATE STORM SEWER EASEMENT BK 2023 PG 14105 1046 1047 1048 1049 1051 1 0 4 5 10 4 5 10 4 5 1 0 5 0 10 4 4 1 0 4 4 1 0 4 6 10 4 6 10 4 6 10 4 7 1 0 4 8 1 0 4 9 1 0 5 1 1 0 5 2 1051 1046 1047 1048 1049 1044 1043 1044 1046 1042 1 0 4 7 10 4 8 1 0 4 9 10 4 6 10 4 1 10 4 2 10 4 3 10 4 4 1 0 5 1 1 0 5 2 1041 1042 1043 1 0 4 1 10 4 2 10 4 3 10 4 4 1046 1044 1044 1046 1047 1 0 4 5 10 4 5 1 0 4 1 1 0 4 1 1 0 4 2 1 0 4 2 1 0 4 3 1 0 4 3 1 0 4 4 1 0 4 4 1 0 4 6 1 0 4 7 10 4 8 10 4 5 10 4 5 10 5 0 10 4 6 10 4 6 10 4 6 10 4 7 10 4 8 10 4 9 1045 1045 1050 1055 1 0 5 5 1043 1043 1044 1044 1046 1046 1047 1048 1049 1051 1052 1053 1054 1042 TOPSOIL NOTES: 1.STRIP AND STOCKPILE THE TOP 8" OF SOIL ON ALL DISTURBED AREAS. 2.RESPREAD TOPSOIL TO A MINIMUM DEPTH OF 8" ON ALL GREEN (NON PAVED) AREAS. IMPORT TOPSOIL AS NECESSARY TO ACHIEVE A MINIMUM DEPTH OF 6". 3.TOPSOIL SHALL BE FREE OF ALL ROCK AND DEBRIS LARGER THAN 3/4" IN SIZE. 4.TOPSOIL IS DEFINED AS: FERTILE, FRIABLE LOAM, CAPABLE OF SUSTAINING VIGOROUS PLANT GROWTH, FROM WELL DRAINED SITE FREE FROM FLOODING, NOT IN FROZEN OR MUDDY CONDITIONS; REASONABLE FREE FROM SUBSOIL, CLAY LUMPS, ROOTS, GRASS, WEEDS, STONES LARGER THAN 3/4 INCH IN DIAMETER, AND FOREIGN MATTER; ACIDITY RANGE (PH) OF 5.5 TO 7.5; CONTAINING MINIMUM 4 PERCENT AND MAXIMUM 20 PERCENT ORGANIC MATTER. 5.CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING ALL TOPSOIL REQUIREMENTS OF NPDES GENERAL PERMIT NO. 2 ARE MET. GR A D I N G P L A N C3.1 REFERENCE NUMBER: 35 0 1 1 0 4 t h S t r e e t De s M o i n e s , I o w a 5 0 3 2 2 - 3 8 2 5 Ph o n e : ( 5 1 5 ) 2 7 6 - 0 4 6 7 F a x : ( 5 1 5 ) 2 7 6 - 0 2 1 7 "P l a n n i n g Y o u r S u c c e s s f u l D e v e l o p m e n t " Bi s h o p E n g i n e e r i n g Ci v i l E n g i n e e r i n g & L a n d S u r v e y i n g E s t a b l i s h e d 1 9 5 9 DRAWN BY: CHECKED BY: REVISION DATE: PROJECT NUMBER: SHEET NUMBER: FR E D D Y ' S S I T E P L A N WA U K E E E , I O W A CC 1ST CITY SET 10/10/23 2ND CITY SET 10/24/23 3RD CITY SET 11/7/23 230336 PR E L I M I N A R Y - N O T F O R C O N S T R U C T I O N GRADING LEGEND: EXISTING CONTOUR PROPOSED CONTOUR FINISHED GROUND ELEVATION TOP OF CURB ELEVATION GUTTER ELEVATION TOP OF WALL ELEVATION BOTTOM OF WALL ELEVATION EDGE OF WALK ELEVATION TOP OF STAIR ELEVATION BOTTOM OF STAIR ELEVATION NOTE: WALL ELEVATIONS SHOWN ON PLAN ARE FINISHED GROUND GRADES AT THE TOP AND BOTTOM OF THE WALL. 150.50E/W 150.50B/W 150.50T/W 150.50G 150.50T/C 150.50 150 150 150.50T/S 150.50B/S L: \ L A N D P R O J E C T S 2 0 2 3 \ 2 3 0 3 3 6 F R E D D Y ' S W A U K E E \ D W G \ C 3 G R A D I N G . D W G 11 / 7 / 2 0 2 3 1 1 : 3 1 : 0 6 A M GRAPHIC SCALE 020 10 20 40 PR O P O S E D T R A S H EN C L O S U R E PR I V A T E D R I V E SE A L I C E ' S R O A D PROPOSED 30.5'X85.85' BUILDING 2,880 SF FFE= 1047.50 STRUCTURE #1 REMOVE EX FES, EXTEND 24" RCP AS NECESSARY & INSTALL SW-501 INTAKE T/C=1046.00 FL(SE)=1038.83 FL(W)=1038.73 D STRUCTURE #2 SW-503 INTAKE T/C=1045.29 FL(NW)=1039.54 FL(N)=1039.79 FL(NE)=1039.64 118LF 15" RCP @ S=0.60% STRUCTURE #4 SW-501 INTAKE T/C=1044.75 FL(W)=1040.74 110LF 15" RCP @ S=0.40% 1,000 GAL GREASE TRAP (REF PLUMB) STRUCTURE #3 48" SW-502 INTAKE T/C=1046.25 FL(SW)=1040.08 FL(E)=1040.18 56LF 15" RCP @ S=1.00% FIELD VERIFY LOCATION, RELOCATE EX HYDRANT & CONNECT TO EX 6" WATER SERVICE S STRUCTURE #10 48" SW-301 MANHOLE RIM=1046.50 INV(N)=1040.19 INV(W)=1039.94 SAN SAN SAN 100LF 6" SAN SWR @ S=2.00% 19LF 4" SAN SWR @ S=3.00% FIELD VERIFY LOCATION & ELEVATION & CONNECT TO EX 6" SANITARY STUB INV=1037.95± INV=1040.75 (REF PLUMB) H Y DREINSTALL EX HYDRANT ASSEMBLY R15 0 ' H Y D R A N T R A D I U S W6"W6" W2" 90LF 6" WATER SERVICE *CRITICAL CROSSING* BOTTOM SANITARY = 1038.80± TOP WATER = 1037.20± 4" N-12 @ S=1.00% MIN, TYP FL @ BLDG = 1043.50 GM G G APPROX LOCATION OF GAS SERVICE (BY UTILITY PROVIDER) TRANSFORMER PAD (SEE DETAIL 13/C6.1) EXTEND 30" RCP @ S=0.30%RELOCATED 30" FES FL=1039.22 CO CLEANOUT FL(S)=1043.04 81LF 8" N-12 @ S=4.00% W6" PROP. LIGHT POLE TYP. PROP LIGHT POLE TYP. EM WV WV 6" VALVE, 6"x6" TEE & 6"x2" REDUCER FIRE RISER ROOM FIRE DEPARTMENT CONNECTION 32LF 2" DOMESTIC WATER W/ 2" VALVE & 90° BEND 29LF 6" FIRE SERVICE II II II 2 3 EX 20' PRIVATE WATER MAIN EASEMENT BK 2023, PG 10323 EX 30' PRIVATE SANITARY SEWER EASEMENT BK 2023, PG 10325 EX 25' PRIVATE STORM SEWER EASEMENT BK 2023, PG 10325 10' PUE BK 2023, PG 10317 EX 25' ELECTRICAL TRANSMISSTION LINE EASEMENT BK 2017, PG 23500 30 ' B U I L D I N G S E T B A C K L I N E EX 40' INGRESS EGRESS EASEMENT BK 2023, PG 10327 EX PRIVATE STORM SEWER EASEMENT BK 2023 PG 14105 UTILITY NOTES: 1.ALL PROPOSED UTILTIES SHALL BE PRIVATE, UNLESS NOTED OTHERWISE. 2.ALL WATER LINES SHALL HAVE A MINIMUM OF 5.5' OF COVER UNLESS NOTED OTHERWISE. 3.FIRE HYDRANT ASSEMBLY SHALL INCLUDE THE TEE, BRANCH, VALVE AND HYDRANT. 4.PIPE LENGTHS CALLED OUT ON PLANS INCLUDE FLARED END SECTION, WHERE APPLICABLE. 5.STORM SEWER CALLED OUT AS RCP MUST BE CLASS III RCP. 6.STORM SEWER CALLED OUT AS N-12 MAY BE EITHER N-12 OR CLASS III RCP. 7.FOR RCP PIPE, ASSOCIATED F.E.S. MUST BE RCP. FOR N-12 PIPE, ASSOCIATED F.E.S. SHALL BE CMP. 8.ALL NYLOPLAST BASINS SHALL HAVE CASTINGS SECURELY FASTENED TO THE BASIN BODY, AND ALL GRATES/LIDS SHALL BE BOLTED DOWN TO THE CASTINGS. 9.TRANSFORMER PAD IS SHOWN FOR REFERENCE ONLY AND MAY NOT BE DRAWN TO ACTUAL SIZE. PAD SHALL CONFORM TO ALL UTILITY COMPANY DESIGN STANDARDS AND SPECIFICATIONS. 10.GREASE INTERCEPTOR AND ANY VENT LINES ARE SHOWN FOR REFERENCE ONLY AND MAY NOT BE DRAWN TO ACTUAL SIZE. REFER TO PLUMBING PLANS FOR DETAILED DRAWINGS AND SPECIFICATIONS. PLUMBING PLANS SHALL TIE INTO SANITARY SERVICE AT LOCATION AND ELEVATION SHOWN ON PLANS. UT I L I T Y P L A N C4.1 REFERENCE NUMBER: 35 0 1 1 0 4 t h S t r e e t De s M o i n e s , I o w a 5 0 3 2 2 - 3 8 2 5 Ph o n e : ( 5 1 5 ) 2 7 6 - 0 4 6 7 F a x : ( 5 1 5 ) 2 7 6 - 0 2 1 7 "P l a n n i n g Y o u r S u c c e s s f u l D e v e l o p m e n t " Bi s h o p E n g i n e e r i n g Ci v i l E n g i n e e r i n g & L a n d S u r v e y i n g E s t a b l i s h e d 1 9 5 9 DRAWN BY: CHECKED BY: REVISION DATE: PROJECT NUMBER: SHEET NUMBER: FR E D D Y ' S S I T E P L A N WA U K E E E , I O W A CC 1ST CITY SET 10/10/23 2ND CITY SET 10/24/23 3RD CITY SET 11/7/23 230336 PR E L I M I N A R Y - N O T F O R C O N S T R U C T I O N L: \ L A N D P R O J E C T S 2 0 2 3 \ 2 3 0 3 3 6 F R E D D Y ' S W A U K E E \ D W G \ C 4 U T I L I T Y . D W G 11 / 7 / 2 0 2 3 1 1 : 3 1 : 1 3 A M GRAPHIC SCALE 020 10 20 40 PR O P O S E D T R A S H EN C L O S U R E PR I V A T E D R I V E SE A L I C E ' S R O A D PROPOSED 30.5'X85.85' BUILDING 2,880 SF FFE= 1047.50 D SSANSANSAN H Y D W6"W 6" W2" GM G G CO W6" EM 104 0 1045 1041 1042 1043 1044 1046 1047 1 0 4 5 10 4 5 10 4 6 1046 1046 1046 1047 1047 1047 1047 1046 10 4 7 1046 1 0 4 6 10 4 6 1 0 4 5 1045 1050 1043 1044 1046 1047 1048 1049 10 4 6 1 0 4 6 10 4 5 WV WV II II II 1052 1050 1045 1043 1045 1047 1047 1045 1043 1043 1045 1050 1048 1049 10 4 0 10 4 5 1 0 5 0 1052 1050 1045 1044 1045 1044 1046 1047 1045 1042 1 0 4 5 1 0 4 4 10 4 5 10 4 4 10 4 5 1 0 4 5 10 4 6 EX 20' PRIVATE WATER MAIN EASEMENT BK 2023, PG 10323 EX 30' PRIVATE SANITARY SEWER EASEMENT BK 2023, PG 10325 EX 25' PRIVATE STORM SEWER EASEMENT BK 2023, PG 10325 10' PUE BK 2023, PG 10317 EX 25' ELECTRICAL TRANSMISSTION LINE EASEMENT BK 2017, PG 23500 30 ' B U I L D I N G S E T B A C K L I N E EX 40' INGRESS EGRESS EASEMENT BK 2023, PG 10327 EX PRIVATE STORM SEWER EASEMENT BK 2023 PG 14105 1046 1047 1048 1049 1051 1 0 4 5 10 4 5 10 4 5 1 0 5 0 10 4 4 1 0 4 4 1 0 4 6 10 4 6 10 4 6 1 0 4 7 1 0 4 8 10 4 9 1 0 5 1 1 0 5 2 1051 1046 1047 1048 1049 1044 1043 1044 1046 1042 1 0 4 7 10 4 8 1 0 4 9 10 4 6 10 4 1 10 4 2 10 4 3 10 4 4 1 0 5 1 1 0 5 2 1041 1042 1043 1 0 4 1 1 0 4 2 10 4 3 10 4 4 1046 1044 1044 1046 1047 KC 1 RO 1 SOD SOD SOD SOD SOD SOD SOD SODSOD SOD SOD SOD SOD SOD SOD SOD AH 1 AW 16 SD 5KF 3 SD 8 SS 27 GL 7PF 1 RO 1 SEED SEED SEED SEED SEED SEED ROCK ROCK AC 6 SS 6 AC 6 SS 6 AC 6 SS 4 AC 6 GL 2 GL 3 HYD KC 1 ER 1 ER 1 ER 1 PF 1 PF 1 LA N D S C A P E P L A N C5.1 REFERENCE NUMBER: 35 0 1 1 0 4 t h S t r e e t De s M o i n e s , I o w a 5 0 3 2 2 - 3 8 2 5 Ph o n e : ( 5 1 5 ) 2 7 6 - 0 4 6 7 F a x : ( 5 1 5 ) 2 7 6 - 0 2 1 7 "P l a n n i n g Y o u r S u c c e s s f u l D e v e l o p m e n t " Bi s h o p E n g i n e e r i n g Ci v i l E n g i n e e r i n g & L a n d S u r v e y i n g E s t a b l i s h e d 1 9 5 9 DRAWN BY: CHECKED BY: REVISION DATE: PROJECT NUMBER: SHEET NUMBER: FR E D D Y ' S S I T E P L A N WA U K E E E , I O W A CC 1ST CITY SET 10/10/23 2ND CITY SET 10/24/23 3RD CITY SET 11/7/23 230336 PR E L I M I N A R Y - N O T F O R C O N S T R U C T I O N GRAPHIC SCALE 020 10 20 40 L: \ L A N D P R O J E C T S 2 0 2 3 \ 2 3 0 3 3 6 F R E D D Y ' S W A U K E E \ D W G \ C 5 L A N D S C A P E . D W G 11 / 7 / 2 0 2 3 1 1 : 3 1 : 2 4 A M GENERAL LANDSCAPE REQUIREMENTS TOTAL SQUARE FOOTAGE OF SITE 52,176 SF REQUIRED OPEN SPACE(20%)10,475 SF GENERAL OPEN SPACE REQUIREMENT TOTAL REQUIRED TREES (1 / 1,000 SF)11 50% MINIMUM REQUIRED TO BE OVERSTORY (6 MINIMUM) TOTAL REQUIRED SHRUBS (1 / 1,000 SF)11 STREET FRONTAGE TREE REQUIREMENTS TOTAL LENGTH OF STREET FRONTAGE 168 LF REQUIRED OVERSTORY TREES (1 / 40 LF)(4.2) 5 SOD: PROVIDE AND INSTALL SOD FROM LOCAL SUPPLIERS. AREAS TO BE SODDED MUST BE FREE OF ALL CONSTRUCTION DEBRIS AND ANY DIRT CLUMPS OVER 1" IN DIAMETER. THOROUGHLY WATER SOD UPON INSTALLATION. CONTRACTOR TO MAINTAIN WATERING UNTIL SOD IS ESTABLISHED (ROOTS KNITTED INTO SUBSURFACE) IRRIGATION NOTES: ·FOR BIDDING PURPOSES, THIS PROJECT DOES NOT INCLUDE A SITE IRRIGATION SYTEM. ·CONTRACTOR SHALL SUBMIT TO THE OWNER OR OWNER'S REPRESENTATIVE A SEPARATE PROPOSAL FOR A SITE IRRIGATION SYSTEM. PROPOSAL SHALL BE DESIGN/BUILD FOR A COMPLETE OPERATIONAL IRRIGATION SYSTEM APPROPRIATE FOR THE SITE. IRRIGATION CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DESIGN, COORDINATION, TESTING, PERMITS, INSPECTIONS, ETC. LEGEND LANDSCAPE NOTES: 1.ALL SODDING, SEEDING & LANDSCAPE PLANTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE URBAN STANDARD SPECIFICATIONS, UNLESS SPECIFIED OTHERWISE. 2.SOD ALL DISTURBED AREAS INCLUDING ROW WITHIN THE CONTRACT LIMITS, UNLESS NOTED OTHERWISE. SOD/SEED LIMITS SHOWN ON PLAN ARE FOR REFERENCE ONLY. FINAL LIMITS MAY CHANGE BASED ON CONSTRUCTION ACTIVITIES. 3.STAKE SOD ON ALL SLOPES 3 : 1 OR GREATER. 4.PLANT QUANTITIES ARE FOR CONTRACTORS CONVENIENCE, THE DRAWING SHALL PREVAIL IF A CONFLICT OCCURS. 5.ALL PLANT MATERIAL SHALL CONFORM TO THE LATEST EDITION OF THE AMERICAN STANDARD FOR NURSERY STOCK (ANSI Z60.1). 6.CONTRACTOR SHALL WARRANTY ALL PLANT MATERIAL FOR A PERIOD OF ONE YEAR FROM THE DATE OF INITIAL ACCEPTANCE. 7.FOR WARRANTY PURPOSES, THE DATE OF INITIAL ACCEPTANCE SHALL BE SUBMITTED IN WRITING TO THE OWNER AND/OR OWNER'S REPRESENTATIVE AFTER ALL PLANT MATERIALS HAVE BEEN INSTALLED AND REVIEWED BY OWNER OR OWNER'S REPRESENTATIVE. PLANT MATERIALS WILL ONLY BE ACCEPTED IF THEY ARE IN AN ALIVE AND THRIVING CONDITION. 8.CONDITIONAL ACCEPTANCE OF PLANT MATERIAL MAY BE GIVEN FOR PLANTS INSTALLED IN A DORMANT CONDITION WITH INITIAL ACCEPTANCE OCCURRING THE FOLLOWING SPRING ONCE THEY ARE SHOWN TO BE ALIVE AND THRIVING. 9.IT IS THE CONTRACTORS RESPONSIBILITY TO REMOVE IDENTIFICATION TAGS AND CORDS ON ALL PLANT MATERIAL PRIOR TO THE COMPLETION OF THE CONTRACT. IDENTIFICATION TAGS (INCLUDING SIZING INFORMATION) MUST BE LEFT ON UNTIL AFTER ACCEPTANCE BY OWNER OR OWNER'S REPRESENTATIVE. 10.CONTRACTOR SHALL PLACE SHREDDED HARDWOOD MULCH AROUND ALL TREES, SHRUBS AND GROUND COVER BEDS TO A DEPTH OF 4 INCHES, UNLESS NOTED. 11.STAKING AND GUYING OF TREES SHALL BE AT THE DISCRETION OF THE CONTRACTOR BASED ON CURRENT ACCEPTED NURSERY STANDARDS. GENERALLY, TREES IN LARGE OPEN AREAS SUBJECT O SIGNIFICANT WIND SHALL BE STAKED. STAKE AND WRAP TREES IMMEDIATELY AFTER PLANTING. CONTRACTOR SHALL ADJUST AND MAINTAIN GUYING TENSION THROUGHOUT THE PLANT ESTABLISHMENT PERIOD. REMOVE ALL STAKES AND GUY WIRES NO MORE THAN ONE YEAR AFTER INSTALLATION. 12.THE LANDSCAPING CONTRACTOR SHALL HAVE ALL UTILITIES LOCATED BEFORE STARTING ANY SITE WORK OR PLANTING. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING UTILITIES. 13.NO LANDSCAPE MATERIAL SHALL BE SUBSTITUTED WITHOUT THE AUTHORIZATION OF THE LANDSCAPE ARCHITECT AND THE CITY OF WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT. 14.ALL EDGING SHALL BE DURAEDGE 3/16" STEEL EDGING - COLOR BLACK, OR APPROVED EQUAL.. 15.CONTRACTOR SHALL BE RESPONSIBLE MAINTAINING APPROPRIATE LEVEL OF WATERING FOR ALL NEW PLANTS FOR A PERIOD OF 30 DAYS. 16.ALL SHRUB AND PERENNIAL PLANTING BEDS SHALL INCORPORATE TYPAR 3301 NONWOVEN LANDSCAPE FABRIC (OR SIMILAR) AND 3" THICK LAYER OF WASHED RIVER ROCK (1.5" NOMINAL SIZE). 17.ALL BEDS TO RECEIVE GRANULAR PRE-EMERGENT WEED CONTROL BEFORE AND AFTER ROCK IS INSTALLED. DO NOT CUT CENTRAL LEADER WRAP TRUNK WITH APPROVED TREE WRAP TO FIRST BRANCH 4" DEEP HARDWOOD MULCH CUT SYNTHETIC CORDS AROUND ROOTBALL AND TRUNK -ENTIRELY REMOVE WIRE BASKETS FROM BALL SET ROOTBALL ON UNDISTURBED SUBGRADE DECIDUOUS TREE PLANTING (TYP.) NOT TO SCALESCALE: SCARIFY SIDES & BOTTOM OF PLANTING PIT STAKING ORIENTATION NORTH NORTH 2 STAKES - 3" CAL. & LESS 3 STAKES - GREATER THAN 3" CAL. 3'-0"SET ROOTBALL FLUSH WITH FINISHED GRADE DO NOT PLACE MULCH IN CONTACT WITH BASE OF TREE PRUNE ANY DEAD/DAMAGED BRANCHING FROM TREE. MAINTAIN OVERALL APPEARANCE. USE HOSE GUARDS AROUND TRUNK ON STAKING WIRE. TIE WIRE TO STEEL POSTS PLACED OUTSIDE PLANT PIT.. LEAVE STAKES IN PLACE NO MORE THAN 1 YEAR FROM INSTALLATION. CONTRACTOR RESPONSIBLE FOR REMOVAL. DECIDUOUS SHRUB DETAIL EVERGREEN SHRUB DETAIL PLANTING ON SLOPES FIRMLY COMPACT SAUCER (USE TOPSOIL) ORIGINAL GROUND LINE SUB-SOIL 4" MULCH PLANTING PIT TWICE THE WIDTH OF ROOTBALL 1 2 SHRUB PLANTING (TYP) NOT TO SCALESCALE: PLANTING SCHEDULE SEED: MIX TO BE "SUDAS TYPE 2", INSTALL WITH HYDROMULCH AND ESTABLISH PER SUDAS SPECIFICATIONS. NOTE: SEED IS FOR USE AS OFF-SITE STABILIZATION ONLY, SEE SWPPP FOR QUANTITIES. EDGING EDGING BETWEEN SODDED AREA AND TRANSFORMER ROCK MOAT RIVER ROCK: SEE NOTE #16 ABOVE. EDGING (5') FROM CURB, INSTALL PLANTS 3' FROM CURB. DE T A I L S S H E E T C6.1 REFERENCE NUMBER: 35 0 1 1 0 4 t h S t r e e t De s M o i n e s , I o w a 5 0 3 2 2 - 3 8 2 5 Ph o n e : ( 5 1 5 ) 2 7 6 - 0 4 6 7 F a x : ( 5 1 5 ) 2 7 6 - 0 2 1 7 "P l a n n i n g Y o u r S u c c e s s f u l D e v e l o p m e n t " Bi s h o p E n g i n e e r i n g Ci v i l E n g i n e e r i n g & L a n d S u r v e y i n g E s t a b l i s h e d 1 9 5 9 DRAWN BY: CHECKED BY: REVISION DATE: PROJECT NUMBER: SHEET NUMBER: FR E D D Y ' S S I T E P L A N WA U K E E E , I O W A CC 1ST CITY SET 10/10/23 2ND CITY SET 10/24/23 3RD CITY SET 11/7/23 230336 PR E L I M I N A R Y - N O T F O R C O N S T R U C T I O N L: \ L A N D P R O J E C T S 2 0 2 3 \ 2 3 0 3 3 6 F R E D D Y ' S W A U K E E \ D W G \ C 6 D E T A I L S . D W G 11 / 7 / 2 0 2 3 1 1 : 3 1 : 3 1 A M 5/8"RESILIENT JOINT FILLER 1/2" GRAY MASTIC JOINT SEALANT MATERIAL DETAIL A: NOT TO SCALE EDGE WITH 1/4 INCH TOOL FOR LENGTH OF JOINT INDICATED IF FORMED; EDGING NOT REQUIRED WHEN CUT WITH DIAMOND BLADE SAW 1" STRUCTURAL STOOP SEE STRUCTURAL SIDEWALK SEALED EXPANSION JOINT, SEE DETAIL A SLOPE AWAY FROM BUILDING PER GRADING PLAN STRUCTURAL STOOP / SIDEWALK TRANSITION DETAIL SCALE NONE 7 C6.1 SLOPE DOWN SLOPE DOWN B B A A PLAN VIEW VARIES 5" PCC WALK CONCRETE BEAM CURB BEYOND SECTION VIEW B-B PARKING LOT PAVEMENT (SEPERATE POUR FROM WALK) 5" PCC WALK SECTION VIEW A-A 6"VARIES, SEE PLAN SEALED 1" EXPANSION JOINT VARIES, SEE PLAN VARIES, SEE PLAN VARIES VARIES NOTES: 1. SIDEWALK CROSS SLOPE SHALL BE 1.5% DESIGN, 2% MAX 2. RAMP RUNNING SLOPE SHALL BE 6.25% DESIGN, 8.33% MAX RAMP WITH BEAM CURB DETAIL SCALE NONE 6 C6.1 BEAM CURB (SEPERATE POUR FROM WALK) BUILDING WALL GRASS SLOPE @ 2% MIN BACK OF CURB FACE OF CURB EDGE OF TURNED DOWN WALK SIDEWALK PAVEMENT GRASS/LANDSCAPING ROADWAY PAVEMENT PLAN VIEW CURB & GUTTER / TURNED DOWN WALK TRANSITION DETAIL SCALE NONE 5 C6.1 48" 20" 6" DIA GALVANIZED STEEL PIPE EMBEDDED IN CONC (DO NOT PAINT BOLLARD) FILL PIPE W/ CONCRETE INSTALL BOLLARD 6" INTO SIDEWALK MEASURED FROM EDGE OF PARKING STALL TO CENTER OF BOLLARD CLASS "A" CONC FOUNDATION CENTERED ON BOLLARD EDGE OF PARKING STALL CONC WALK. SEE OTHER DETAILS MUTCD R7-8 (RESERVED PARKING) SIGN 2"x2" SQUARE BLACK POWDER COATED STEEL POLE MUTCD R7-8a OR R7-8b (VAN ACCESSIBLE) SIGN AS CALLED OUT ON PLANS STEEL POLE CEMENTED INTO BOLLARD CENTER NOTE: FOR HANDICAP STALLS IN FRONT OF CURB, INSTALL POLE 2' FROM BACK OF CURB. DIRECT BURY POLE 4' MIN INTO GROUND WITHOUT INSTALLING BOLLARD 24"36"60" 1/2" FOAM AROUND BOLLARD SEAL FOAM W/ GRAY MASTIC JOINT SEALANT 6" BOLLARD W/ PARKING SIGN DETAIL SCALE NONE 8 C6.1 TURNED DOWN WALK DETAIL SCALE NONE 3 C6.1 SLOPE PER PLANS 1.5% MAX CROSS SLOPE ROADWAY PAVEMENT 6" MAX (DIRECTION SHOWN ON GRADING PLANS) VARIES 5/8"RESILIENT JOINT FILLER 1/2" GRAY MASTIC JOINT SEALANT MATERIAL DETAIL A: NOT TO SCALE EDGE WITH 1/4 INCH TOOL FOR LENGTH OF JOINT INDICATED IF FORMED; EDGING NOT REQUIRED WHEN CUT WITH DIAMOND BLADE SAW 1" NOTES: *IMPORTANT:* 1" EXPANSION JOINT BETWEEN ROADWAY PAVEMENT AND WALK MUST BE INSTALLED TO FULL DEPTH OF SLAB. FINISH W/ 3/4" RADIUS TOOL SEALED 'E' JOINT SEE DETAIL A & NOTES 6" 8' LONG #4 BARS 24" O/C BOTH WAYS ALL REINFORCEMENT SHALL BE EPOXY COATED 6" 1" NOMINAL 12"24" MIN SEE PAVEMENT SECTION FOR SUBGRADE INFO 3"4.5" 6" 8" R 1" R 2" 24" 24" 3"4.5" 6" 7" R 1" R 2" NOTES: 1.SLOPE GUTTER IN ACCORDANCE WITH GRADING PLAN. 2.INSTALL CURB & GUTTER INTERGRAL WITH PAVING. 3.PCC PAVEMENT SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 4,000 PSI. TYPE 1 PAVEMENT SECTION SCALE NONEC6.1 1 7" PCC C4 MIX 6" ROCK BASE IOWA DOT 4123 12" SUBGRADE PREPARATION IN TWO 6" LIFTS 8" PCC C4 MIX 12" SUBGRADE PREPARATION IN TWO 6" LIFTS NOTES: 1.SLOPE GUTTER IN ACCORDANCE WITH GRADING PLAN. 2.INSTALL CURB & GUTTER INTERGRAL WITH PAVING. 3.PCC PAVEMENT SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 4,000 PSI. 4.ALL REINFORCEMENT SHALL BE EPOXY COATED. COMPACTED BACKFILL COMPACTED BACKFILL #5 BARS 24" O/C BOTH WAYS TYPE 2 PAVEMENT SECTION SCALE NONEC6.1 2 6" ROCK BASE IOWA DOT 4123 SIDEWALK DETAIL SCALE NONE 4 C6.1 FINISHED GROUND GRADE (INCLUDING SOD) SHALL BE 1/4" BELOW FINISHED PAVEMENT GRADE ON DOWNHILL SIDE WIDTH PER PLAN NOTE: SLOPE SIDEWALK IN ACCORDANCE WITH GRADING PLAN, 1.5% CROSS SLOPE 4" ROCK BASE SEE SPEC SECTION 32 11 23 5" MIN WALK THICKNESS - SEE PLANS FOR EXACT THICKNESS 4" ROCK BASE IOWA DOT 4123 12" 12" INSTALL CAP ON TOP OF POLE 11 C6.1 STORM CLEANOUT DETAIL SCALE NONE 9 C6.1 NYLOPLAST COUPLING (ADS CODE 1579 AG) SCH. 40 PVC TO N-12 (REDUCING COUPLING AS NECESSARY) SCH. 40 PVC ROOF DRAIN LINE (REF MECH) HDPE STORM SEWER (SEE SITE PLAN) ROOF DRAIN CONNECTION DETAIL SCALE NONE 10 C6.1 18 " M I N STORM OR SANITARY SEWER WATER MAIN LOCATED ONE FULL LENGTH OF PIPE SO BOTH JOINTS ARE AS FAR AS POSSIBLE FROM THE WATER MAIN WATER MAIN & STORM OR SANITARY SEWER CROSSING DETAIL SCALE NONE 12 C6.1 NOTES: 1.THIS DETAIL SHALL APPLY ANY TIME A STORM SEWER OR SANITARY SEWER CROSSES OVER OR LESS THAN 18 INCHES BELOW A WATER MAIN. 2.WHEN WATER MAIN CROSSES UNDER STORM OR SANITARY SEWER THE CONTRACTOR SHALL MAINTAIN A MINIMUM OF 18" OF SEPARATION. 3.STORM OR SANITARY SEWER MAY NOT BE PLACED CLOSER THAN 6" BELOW A WATER MAIN. 4.MAINTAIN THE MAXIMUM FEASIBLE SEPARATION IN ALL CASES. 5.SEWER AND WATER PIPES MUST BE ADEQUATELY SUPPORTED & HAVE WATERTIGHT JOINTS. 6.CONTRACTOR SHALL INSTALL LOW PERMEABILITY SOIL FOR BACKFILL MATERIAL WITHIN 10 FEET OF THE CROSSING. 7.IN SANITARY SEWER CROSSINGS, CONTRACTOR SHALL INSTALL ONE FULL LENGTH OF SANITARY SEWER OF WATER MAIN PIPE MATERIAL WITH WATERTIGHT JOINTS LOCATED AS FAR AS POSSIBLE FROM THE CROSSING. 8.IN STORM SEWER CROSSINGS, THE CONTRACTOR SHALL INSTALL ON FULL LENGTH OF STORM SEWER PIPE OF WATER MAIN MATERIAL OR RCP WITH GASKETED JOINTS LOCATED AS FAR AS POSSIBLE FROM THE CROSSING. 9.GASKETED JOINTS SHALL COMPLY WITH ASTM C443. 6" - 1 8 " WATER MAIN TRANSFORMER PAD MOAT DETAIL NOT TO SCALE 13 C6.1 CONTRACTOR TO INSTALL REINFORCED CONCRETE TRANSFORMER PAD (PER MID-AMERICAN STANDARDS) REFERENCE ELECTRICAL PLANS TRANSFORMER 3' 3' 3' 3' SEE LANDSCAPE PLAN FOR MATERIAL EDGING WHERE SHOWN ON LANDSCAPE PLAN REINFORCED CONCRETE TRANSFORMER PAD (PER MID-AMERICAN STANDARDS) 3' 2'2' 3'LINE TRENCH WITH SILT FENCE FABRIC (OR OTHER SOIL FABRIC WITH EQUAL OR LOWER POROSITY) EDGING WHERE SHOWN ON LANDSCAPE PLAN MATERIAL TO MATCH LANDSCAPE PLAN METAL STRUT FOR METER (SEE ELEC) PVC & N-12 PIPE BEDDING SCALE NONE 48" 20" 6" DIA GALVANIZED STEEL PIPE EMBEDDED IN CONC (DO NOT PAINT BOLLARD) FILL PIPE W/ CONCRETE CLASS "A" CONC FOUNDATION CENTERED ON BOLLARD STEEL POLE CEMENTED INTO BOLLARD CENTER 24"36" 6" BOLLARD DETAIL SCALE NONE 14 C6.1 PR O P O S E D T R A S H EN C L O S U R E PR I V A T E D R I V E SE A L I C E ' S R O A D PROPOSED 30.5'X85.85' BUILDING 2,880 SF FFE= 1047.50 D SSANSANSAN H Y D W6"W6" W2" GM G G CO W6" EM 104 0 1045 1041 1042 1043 1044 1046 1047 1 0 4 5 10 4 5 10 4 6 1046 1046 1046 1047 1047 1047 1047 1046 10 4 7 1046 1 0 4 6 10 4 6 1 0 4 5 1045 1050 1043 1044 1046 1047 1048 1049 10 4 6 1 0 4 6 10 4 5 WV WV II II II 2 1052 1050 1045 1043 1045 1047 1047 1045 1043 1043 1045 1050 1048 1049 10 4 0 10 4 5 1 0 5 0 1052 1050 1045 1044 1045 1044 1046 1047 1045 1042 1042 1 0 4 5 1 0 4 4 10 4 5 10 4 4 10 4 5 1 0 4 5 10 4 6 10 4 1 10 4 2 1 0 4 3 1 0 4 4 EX 20' PRIVATE WATER MAIN EASEMENT BK 2023, PG 10323 EX 30' PRIVATE SANITARY SEWER EASEMENT BK 2023, PG 10325 EX 25' PRIVATE STORM SEWER EASEMENT BK 2023, PG 10325 10' PUE BK 2023, PG 10317 EX 25' ELECTRICAL TRANSMISSTION LINE EASEMENT BK 2017, PG 23500 EX 40' INGRESS EGRESS EASEMENT BK 2023, PG 10327 EX PRIVATE STORM SEWER EASEMENT BK 2023 PG 14105 1046 1047 1048 1049 1051 1 0 4 5 10 4 5 10 4 5 1 0 5 0 10 4 4 1 0 4 4 1 0 4 6 10 4 6 10 4 6 1 0 4 7 1 0 4 8 1 0 4 9 1 0 5 1 1 0 5 2 1051 1046 1047 1048 1049 1044 1043 1044 1046 1042 1 0 4 7 10 4 8 1 0 4 9 10 4 6 10 4 1 10 4 2 10 4 3 10 4 4 1 0 5 1 1 0 5 2 1041 1042 1043 1 0 4 1 1 0 4 2 10 4 3 10 4 4 1046 1044 1044 1046 1047 ROCK CONSTRUCTION ENTRANCE POSSIBLE ROCK STAGING & PARKING AREA W/ TEMPORARY RESTROOM FACILITIES & DUMPSTER 50' APPROXIMATE LIMITS OF DISTURBANCE SILT FENCE, TYP SITE DISCHARGE LOCATION TO AN UNNAMED TRIBUTARY OF LITTLE WALNUT CREEK POSSIBLE TOPSOIL STOCKPILE LOCATION SF SF INLET PROTECTION, TYP SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF S F SILT FENCE, TYP SW P P P C7.1 REFERENCE NUMBER: 35 0 1 1 0 4 t h S t r e e t De s M o i n e s , I o w a 5 0 3 2 2 - 3 8 2 5 Ph o n e : ( 5 1 5 ) 2 7 6 - 0 4 6 7 F a x : ( 5 1 5 ) 2 7 6 - 0 2 1 7 "P l a n n i n g Y o u r S u c c e s s f u l D e v e l o p m e n t " Bi s h o p E n g i n e e r i n g Ci v i l E n g i n e e r i n g & L a n d S u r v e y i n g E s t a b l i s h e d 1 9 5 9 DRAWN BY: CHECKED BY: REVISION DATE: PROJECT NUMBER: SHEET NUMBER: FR E D D Y ' S S I T E P L A N WA U K E E E , I O W A CC 1ST CITY SET 10/10/23 2ND CITY SET 10/24/23 3RD CITY SET 11/7/23 230336 PR E L I M I N A R Y - N O T F O R C O N S T R U C T I O N STORM WATER POLLUTION PREVENTION PLAN NOT TO SCALE SITE ENTRANCE DETAIL TEMP. ROCK ENTRANCE (PLAN VIEW) (PROFILE VIEW) TEMP. ROCK ENTRANCE 3" CLEAN LIMESTONE PLACE ROCK ON FABRIC STABILIZED ENTRANCE SHALL BE AT LEAST 50' LONG AND EXTEND TO THE PUBLIC ROADWAY. 5' - 0 " M I N . GROUND LINE ENGINEERING FABRIC FLOW 2 1' ABOVE GROUND LINE VARIABLE 10' MAX.5' MAX.5' MAX.10' MAX. 1' ABOVE GROUND LINE SECURE TOP OF ENGINEERING FABRIC ENGINEERING FABRIC TO BE PLACED TO BOTTOM OF TRENCH. 1 2 ENGINEERING FABRIC GROUND LINE TRENCH BOTTOM TRENCH BOTTOM 1 1 1 LINE GROUND 1 MIN. 4" EXCESS FABRIC COMPACTED BACKFILL 12 " MI N . DETAIL OF SILT FENCE AT DITCH OR SWALE DETAIL OF SILT FENCE 8' SPACING TO TOP OF STEEL POST. SEE DETAIL OF ATTACHMENT TO POST. VERTICAL CUT WIRE CORD CORD CORD WIRE POST FABRIC FABRIC BACK VIEW OF FABRIC BACK VIEW ATTACHMENT TO POST 3 4 NOTES : 3 MAKE VERTICAL CUT IN TOP OF FABRIC. PULL OUT AND TWIST CORD.4 LOOP CORD AROUND POST FORMING A LOOP. PULL WIRE THROUGH FOLD AREA OF FABRIC AND SECURE AROUND POST. 'T' STEEL FENCE POST NORMAL FORESLOPE 2" RISE IN FENCE 31" MIN. NORMAL BACKSLOPE 31 " M I N . 6" TRENCH DEPTH FOR NORMAL INSTALLATION (MIN.) 12" TRENCH DEPTH FOR DITCH INSTALLATION NOT TO SCALE (SECTION VIEW) (PROFILE VIEW) SILT FENCE DETAILS NOT TO SCALE INLET 5'-0" 5'-0" 'T' FENCE POST, 5' MIN. NOTES: 1. SECURE TOP OF FABRIC TO POSTS, USING CABLE TIES OR WIRE. 2. FABRIC TO BE BURIED 12", AND FOLDED ALONG BOTTOM. 3. STEEL POSTS TO BE EMBEDDED 28". (PLAN VIEW) DROP INLET BASKET PROTECTION SILT FENCE FABRIC IF APPLICABLE INLET PROTECTION DETAIL NOT TO SCALE NOTES: 1. 1 C.Y. CONCRETE BAG SHALL BE REQUIRED AT ANY LOCATION WHERE CONCRETE IS USED. 2. CONCRETE WASHOUT DUMPSTER W/ HEAVY DUTY LINER IS AN ACCEPTIBLE ALTERNATIVE (PLAN VIEW) 1 C.Y. CONCRETE WASH-OUT BAG 'T' FENCE POST 5' MIN CONCRETE WASH-OUT BAG DETAIL (PROFILE VIEW) 1 C.Y. CONCRETE WASH-OUT BAG L: \ L A N D P R O J E C T S 2 0 2 3 \ 2 3 0 3 3 6 F R E D D Y ' S W A U K E E \ D W G \ C 7 S W P P P . D W G 11 / 7 / 2 0 2 3 1 1 : 3 1 : 4 2 A M GRAPHIC SCALE 020 10 20 40 EROSION CONTROL NOTES: 1.SEE SUPPLEMENTAL DETAIL STORM WATER POLLUTION PLAN NARRATIVE FOR ALL EROSION CONTROL MEASURES, ADDITIONAL DETAILS AND NOTE. ADDITIONAL NOTES AND MEASURES IN NARRATIVE SHALL BE CONSIDERED INCIDENTAL AND SHALL BE INCLUDED IN THE ORIGINAL BID. 2.SWPPP PLAN AND NARRATIVE ARE CONSIDERED A LIVING DOCUMENT AND WILL NEED PERIODIC UPDATES AND ADJUSTMENTS AS NECESSARY DEPENDING ON SITE CONDITIONS TO ASSURE COMPLIANCE WITH NPDES GENERAL PERMIT NO. 2. IT IS THE CONTRACTOR'S RESPONSIBILITY TO UPDATE THE SWPPP AND IMPLEMENT ANY AND ALL MEASURES NECESSARY TO COMPLY WITH SAID PERMIT NO. 2. 3.INSTALL PERIMETER SILT FENCE AS SHOWN ON PLANS PRIOR TO CONSTRUCTION. 4.INSTALL INTAKE PROTECTION WITH SILT FENCE IMMEDIATELY AFTER STORM SEWER CONSTRUCTION. 5.INSTALL FINISHED PAVING INLET PROTECTION IMMEDIATELY AFTER PAVING IS COMPLETED AROUND INTAKE. 6.OTHER EROSION CONTROL TYPES MAY NOT BE SUBSTITUTED FOR SILT FENCE. 7.CONTRACTOR SHALL BE RESPONSIBLE FOR SUPPLYING A CONCRETE WASHOUT IN ACCORDANCE WITH NPDES GENERAL PERMIT NO. 2 DURING ALL CONCRETE WORK. CONCRETE WASHOUT SHALL MEET SUDAS SPEC 11050. 8.CONTRACTOR SHALL BE RESPONSIBLE FOR SUPPLYING TEMPORARY RESTROOM FACILITIES. SANITARY WASTE SHALL BE DISPOSED OF PER ALL FEDERAL, STATE AND LOCAL REGULATIONS. 9.CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING ALL TOPSOIL REQUIREMENTS OF NPDES GENERAL PERMIT NO. 2 ARE MET. 10.THIS PROJECT INCLUDES SAWCUTTING OR CONCRETE GRINDING SO PROTECTION OF STORM SEWERS AND DRAINAGE WAYS WILL NEED TO BE PROVIDED FROM SLURRY FROM THE CONCRETE OPERATIONS TO DISCHARGE OFFSITE. SEE SWPPP SHEET AND NARRATIVE FOR ADDITIONAL DETAILS. 11.CONTRACTOR SHALL PROVIDE APPROPRIATE CONTROLS TO PREVENT DISCHARGES FROM ANY AND ALL DEWATERING ACTIVITIES. 12.SEE LANDSCAPE PLAN FOR FINAL STABILIZATION INCLUDING SEEDING AND SODDING AREAS. 13.PER NPDES GENERAL PERMIT NO. 2, IF CONSTRUCTION ACTIVITY IS NOT PLANNED FOR AT LEAST 14 DAYS, ALL DISTURBED AREAS SHALL BE STABILIZED IMMEDIATELY BY TEMPORARY EROSION CONTROL MEASURES. 14.THE FOLLOWING DISCHARGES ARE PROHIBITED: WASTEWATER FROM WASHOUT AND CLEANOUT OF STUCCO, PAINT, FORM RELEASE OIL, CURING COMPOUNDS AND OTHER CONSTRUCTION MATERIALS, FUEL, OILS OR OTHER POLLUTANTS USED IN VEHICLE AND EQUIPMENT OPERATION AND MAINTENANCE, AND SOAPS OR SOLVENTS USED IN VEHICLE AND EQUIPMENT WASHING EROSION CONTROL REMOVAL NOTES: 1.AFTER FINAL STABILIZATION HAS OCCURED, AS DEFINED IN NPDES GENERAL PERMIT NO. 2, CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL TEMPORARY EROSION CONTROL DEVICES INCLUDING, BUT NOT LIMITED TO: SILT FENCE, INLET PROTECTION, AND TEMPORARY STANDPIPES. EROSION CONTROL QUANTITIES: DISTURBED AREA 1.6 ACRES (PERMIT IS REQUIRED) SILT FENCE 750 LF INLET PROTECTION 5 EA CONSTRUCTION ENTRANCE 1 EA CONCRETE WASHOUT 1 EA PERMANENT SOD 1,000 SF TYPE 2 PERMANENT SEED 20,000 SF **SEE LANDSCAPE PLAN FOR SEEDING/SOD TYPES & LOCATIONS** TEMPORARY SEEDING (SUDAS TYPE 4)AS NECESSARY *NOTE: EROSION CONTROL QUANTITIES ARE PROVIDED FOR CITY REQUIREMENT ONLY AND ARE A ROUGH ESTIMATE. CONTRACTOR SHALL PROVIDE EROSION CONTROL MEASURES AS NECESSARY TO MEET SITE CONDITIONS. AWNING METAL DECORATIVE GUARDRAIL BRICK COLUMN METAL CAP BRICK COLOR: GUNSTOCK METAL COPING CAP EXTERIOR INSULATION & FINISH SYSTEM STOREFRONT STONE BASE BRICK COLOR: GUNSTOCK ROOF ACCESS LADDER STOREFRONT BRICK COLOR: SEASHELL METAL COPING CAP METAL COPING CAP BRICK METAL COPING CAP EXTERIOR INSULATION & FINISH SYSTEM BRICK AWNING METAL DECORATIVE GUARDRAIL STOREFRONTBRICK COLUMNS STONE BASE MATERIAL COMPOSITION MATERIAL NORTH EAST SOUTH WEST BRICK 1,285 SF (67%) 340 SF (39%) 888 SF (46%) 554 SF (78%) E.I.F.S.421 SF (22%) 201 SF (23%) 470 SF (25%) 119 SF (17%) METALS 64 SF (3%) 142 SF (17%) 203 SF (11%) 10 SF (2%) STOREFRONT 88 SF (5%) 169 SF (20%) 232 SF (12%) STONE BASE 58 SF (3%) 11 SF (1%) 38 SF (2%) 23 SF (3%) NICHIHA WALL PANELS 83 SF (4%) TOTAL 3,067 SF (57%) 1,211 SF (22%) 419 SF (8%) 130 SF (2%) TOTAL 1,924 SF 863 SF 1,913 SF 706 SF 489 SF (9%) 83 SF (2%) MATERIAL LEGEND DRYVIT 386 A Pure Cream DRYVIT 614 Smoke Signal MARION CERAMICS 410 Gunstock Brown NICHIHA VINTAGEWOOD CEDAR MARION CERAMICS 710 Seashell DATE: PROGRESS PRINTNOT FOR CONSTRUCTIONFI L E P A T H : DATE: PROJECT NO: CHECKED BY: DRAWN BY: STORE NO:XXXX Ar c h i t e c t u r e · E n g i n e e r i n g · P l a n n i n g · In t e r i o r D e s i g n · L a n d s c a p e A r c h i t e c t u r e 345 RIVERVIEW, WICHITA, KS 67203 T 316.268.0230 F 316.268.0205 LK Ar c h i t e c t u r e 10/30/2023 4:26:18 PM C: \ U s e r s \ j a g u i l e r a \ D o c u m e n t s \ 2 3 2 3 4 _ F r e d dy ' s _ W a u k e e I A _ v 2 2 _ j a g u i l e r a S 6 M W N . r v t ELEVATIONS CP-300 23234 10.06.2023 Checker Fr e d d y ' s F r o z e n C u s t a r d Wa u k e e , I o w a Fr e d d y ' s - F r o z e n C u s t a r d Author 1 NORTH ELEVATION 2 EAST ELEVATION DESCRIPTION DATE METAL COPING CAP ROOF ACCESS LADDER BEYOND BRICK COLOR: GUNSTOCK METAL DOOR EXTERIOR INSULATION & FINISH SYSTEM STONE BASE BRICK COLOR: GUNSTOCK NICHIHA WOOD PLANKS STOREFRONT STOREFRONT EXTERIOR INSULATION & FINISH SYSTEM BRICK COLOR: GUNSTOCK METAL DECORATIVE PANEL METAL DECORATIVE GUARDRAIL BEYOND AWNING METAL CAP BRICK COLUMN BRICK COLOR: SEASHELL METAL COPING CAP BRICK COLOR: GUNSTOCK AWNING STONE BASE ELECTRICAL SERVICE EQUIPMENT STONE BASELINE OF WASTE OIL TANKS EXTERIOR INSULATION & FINISH SYSTEM ROOF ACCESS LADDER BRICK COLOR: GUNSTOCK BRICK COLOR: SEASHELL MATERIAL COMPOSITION MATERIAL NORTH EAST SOUTH WEST BRICK 1,285 SF (67%) 340 SF (39%) 888 SF (46%) 554 SF (78%) E.I.F.S.421 SF (22%) 201 SF (23%) 470 SF (25%) 119 SF (17%) METALS 64 SF (3%) 142 SF (17%) 203 SF (11%) 10 SF (2%) STOREFRONT 88 SF (5%) 169 SF (20%) 232 SF (12%) STONE BASE 58 SF (3%) 11 SF (1%) 38 SF (2%) 23 SF (3%) NICHIHA WALL PANELS 83 SF (4%) TOTAL 3,067 SF (57%) 1,211 SF (22%) 419 SF (8%) 130 SF (2%) TOTAL 1,924 SF 863 SF 1,913 SF 706 SF 489 SF (9%) 83 SF (2%) MATERIAL LEGEND DRYVIT 386 A Pure Cream DRYVIT 614 Smoke Signal MARION CERAMICS 410 Gunstock Brown NICHIHA VINTAGEWOOD CEDAR MARION CERAMICS 710 Seashell DATE: PROGRESS PRINTNOT FOR CONSTRUCTIONFI L E P A T H : DATE: PROJECT NO: CHECKED BY: DRAWN BY: STORE NO:XXXX Ar c h i t e c t u r e · E n g i n e e r i n g · P l a n n i n g · In t e r i o r D e s i g n · L a n d s c a p e A r c h i t e c t u r e 345 RIVERVIEW, WICHITA, KS 67203 T 316.268.0230 F 316.268.0205 LK Ar c h i t e c t u r e 10/30/2023 4:29:46 PM C: \ U s e r s \ j a g u i l e r a \ D o c u m e n t s \ 2 3 2 3 4 _ F r e d dy ' s _ W a u k e e I A _ v 2 2 _ j a g u i l e r a S 6 M W N . r v t ELEVATIONS CP-301 23234 10.06.2023 Checker Fr e d d y ' s F r o z e n C u s t a r d Wa u k e e , I o w a Fr e d d y ' s - F r o z e n C u s t a r d LK 1 SOUTH ELEVATION 2 WEST ELEVATION DESCRIPTION DATE 10"8" AS-300 29 PT CONTINUOUS SILL PLATE W/ 5/8" O.D. X 11" O.D. GAL BOLTS 4'-0" O.C. TYP REF STRUCT. NEW STEM WALL. REF STRUCTURAL LOW PROFILE STANDING SEAM METAL ROOF TO BE DUROLAST/EXCEPTIONAL METALS' EM CRAFTSMAN SMALL BATTEN SERIES WITH CONCEALED FASTENERS, ROOF & COPING TO BE PREFINISHED SILVER METALLIC BU T N O T L E S S T H A N 2 ' - 6 " B E L O W G R A D E 6" B E L O W F R O S T L I N E 18" 1' - 0 " NICHIHA PANELS 2X6 STUD FRAMING @ 16" O.C. 2X6 STUD FRAMING FLASHING BUILDING WRAP ON 1/2" PLYWOOD SHEATHING KICKOUT FLASHING. 2" MIN TO CLEAR GRADE SILL ANCHORS 13 AS-300 NOTE: ALL SILL PLATES SHALL BE 2X6 TREATED LUMBER, TYP. WOOD DECKING, RE: STRUCTURAL AS-300 24 8' - 3 7/8" T.O. FRAMING VARIES 100' - 6" 100' - 0" 100' - 6" SILL ANCHORS 16" OC SET DURING CONCRETE POUR. CONTINUOUS TREATED 2X SILL PLATE TYP. REF STRUCT. VINTAGE WOOD CEDAR NICHIHA PANELS OVER WEATHER RESISTIVE BARRIER ON 1/2" PLYWOOD SHEATHING OVER 2X6 FRAMING, REF STRUCT. PRE-FINISHED COPING, SILVER MATALLIC FINISH. A.F.F. BU T N O T L E S S T H A N 2 ' - 6 " B E L O W G R A D E 6" B E L O W F R O S T L I N E 18" 5' - 2 " 4" KICK-OUT FLASHING BENEATH FFS CAST FOUNDATION STONE TYP BOTH SIDES. 1'-6" 6" 1' - 6 " AS-300 15 106' - 8" 6' - 8 " LOW PROFILE STANDING SEAM METAL ROOF TO BE DUROLAST/ EXCEPTIONAL METALS' EM CRAFTSMAN SMALL BATTEN SERIES WITH CONCEALED FASTENERS, ROOF & COPING TO BE PREFINISHED SILVER METALLIC VINTAGE WOOD CEDAR NICHIHA PANELS OVER WEATHER RESISTIVE BARRIER ON 1/2" PLYWOOD SHEATHING OVER 2X6 FRAMING, RE:STRUCTURAL STORAGE SHED FLOOR SLAB AT 100'-6" AFF SHEATING AND NICHIHA PANELS CONTINUOUS BETWEEN SCREEN WALL AND BACK WALL OF SHED. INSTALL EXPANSION JOINTS PER MANUFACTURER'S RECOMMENDED INSTRUCTIONS 4" PRE-FINISHED GUTTER SILVER METALLIC 3"X4" PRE-FINISHED DOWNSPOUT SILVER METALLIC 11 AS-300 13 AS-300 LOW PROFILE STANDING SEAM METAL ROOF TO BE DUROLAST/EXCEPTIONAL METALS' "EM CRAFTSMAN SMALL BATTEN" SERIES WITH CONCEALED FASTENERS, ROOF & COPING TO BE PREFINISHED SILVER METALLIC PRE-FINISHED METAL FLASHING HARDIE BOARD FASCIA PAINT COLOR:XX HARDIE BOARD SOFFIT PAINT COLOR: 1'-0"2X6 STUDS NICHIHA PANELS BUILDING WRAP ON 1/2" PLYWOOD SHEATHING 2X6 RAFTER W/ 2X4 PURLINS RE: STRUCTURAL DOUBLE TOP PLATE #30 ROOFING FELT AS-300 24 AS-300 27AS-300 26 7' - 7 3/16"T.O. FRAMING VARIES 8' - 5 3/8"T.O. FRAMING VARIES 5/8" PLYWOOD PEAK CAP WOOD BLOCKING 12-11 X 1 PANCAKE HEAD SELF-TAPPER [FASTENER #13A] @ 12" O.C. CONTINUOUS CLEAT URETHANE SEALANT @ CLOSURE & BATTEN ENDS 1/8 X 3/16 POP RIVET [FASTENER #14] (1) PER CONN. @ EA. BATTEN 1/8 X 3/16 POP RIVET [FASTENER #14] @ 12" O.C. (DO NOT RIVET THROUGH TOP OF BATTEN) TRI-BEAD TAPE SEALER [HW-504] TOP & BOT. OF CLOSURE ZEE CLOSURE [T-5011] (FIELD CUT TO LENGTH) EM CRAFSTMAN SB BATTEN CAP [FL-566] (STOP BATTEN 1" FROM END OF PANEL) EM CRAFTSMAN SB PANEL 1/2" OFFSET CLEAT [T-5131] TRI-BEAD TAPE SEALER [HW-504] 12-11 X 1 PANCAKE HEAD SELF-TAPPER [FASTENER #13A] @ 6" O.C. 12-11 X 1 PANCAKE HEAD SELF-TAPPER [FASTENER #13A] @ 5'-0" O.C. WOOD BLOCKING FILL END W/ URETHANE SEALANT GUTTER STRAP [T-5281] @ 3'-0" O.C. MAX5/8" PLYWOOD EM CRAFTSMAN SB CLIP [HW-4500] EM CRAFTSMAN SB BATTEN CAP [FL-566] EM CRAFTSMAN SB PANEL 1'-0" 12-11 x 1 PANCAKE HEAD SELF-TAPPER [FASTENER #13A] (1) PER CLIP 1/8 X 3/16 POP RIVET [FASTENER #14] (2) PER STRAP BOX GUTTER [T-5262] 2X6 STUD FRAMING @ 16" O.C. BUILDING WRAP ON 1/2" PLYWOOD SHEATHING KICKOUT FLASHING. 2" MIN TO CLEAR GRADE SILL ANCHORS FINISH GRADE RE: CIVIL 2X6 WOOD STUD FRAMING @ 16" O.C. VINTAGE WOOD CEDAR NICHIHA PANELS SILL ANCHORS @ 16" O.C. , SET DURING CONCRETE POUR CONTINUOUS TREATED 2X SILL PLATE, TYP. RE:STRUCTURAL CONCRETE FOOTING, RE: STRUCTURAL BUILDING WRAP ON 1/2" EXTERIOR GRADE PLYWOOD SHEATHING SILL FLASHING FFS CAST FOUNDATION STONE, BOTH SIDES - --- DRAIN, REF. PLUMBING 18 ' - 0 " 1'-2 3/4"12'-1"1'-4 1/2" 13'-2 1/4" 1'-0" 3' - 4 " 5' - 4 " 3' - 4 " 2' - 1 1 1 / 4 " 2' - 1 1 1 / 4 " 1' - 6 " 1 6 ' - 3 3 / 4 " 1 ' - 2 3 / 4 " 6" O.D. 48" HIGH PIPE BOLLARD (TYP. OF 4) EMBED 24" MIN. INTO CONC. PIER - REF. 16/AS100 100' - 0" STORAGE SHED WALLS - 2x6 @ 16" O.C., W/ 1/2" EXTERIOR SHEATHING AND SKINS TO MATCH BUILDING. VERIFY W/ STRUCT. ROOF - 2x6 @ 24" O.C., WITH 2x4 PURLINS AND PRE- FINISHED METAL ROOF & COPING. DOOR - HOLLOW METAL DOOR AND FRAME W/ STORAGE ROOM LOCK. PROVIDE WEATHER TIGHT STORAGE ENCLOSURE W/ ALL FLASHING AND TRIM REQUIRED. 100' - 6" NOTE: PROVIDE LIGHTING ON OCCUPANCY SENSOR AND ONE POWER OUTLET. REF. ELECTRICAL 13'-9" 5' - 5 " 7 5' - 4 " 10 ' - 9 " 10 ' - 3 1 / 2 " 18 ' - 7 " 29 ' - 4 " 11 AS-300 11 AS-300 13 AS-300 21 AS-300 Sim AS-300 4 AS-300 23 AS-300 19 AS-300 5 NOTE: STEEL POST HAS BEEN SET IN CURED CONCRETE - SECURE GATE & LIFT OVER STEEL POST - SLOWLY LOWER GATE TUBE OVER 6" POST - GATE IS SET WHEN DISTANCE BETWEEN GRADE AND GATE BOTTOM IS 4" VINTAGE WOOD CEDAR NICHIHA PANELS OVER WEATHER RESISTIVE BARRIER ON 1/2" PLYWOOD SHEATHING OVER 2X6 FRAMING, RE:STRUCTURAL LOW PROFILE STANDING SEAM METAL ROOF TO BE DUROLAST/EXCEPTIONAL METALS' EM CRAFTSMAN SMALL BATTEN SERIES WITH CONCEALED FASTENERS, ROOF & COPING TO BE PREFINISHED SILVER METALLIC GUTTERS & DOWN SPOUTS 6" SCHEDULE 40 GALVANIZED STEEL POST HEIGHT OF POST NEEDS TO BE SET AT 7" BELOW DESIRED FINISHED HEIGHT OF GATE. IE, 72" FINISHED HEIGHT OF GATE, POST SHOULD BE SET AT 65". FILL WITH CONCRETE AND STRIKE OFF FLAT AT TOP OF POST. MINIMUM 3" CLEARANCE AROUND 6" GALV. POST TO ALLOW 9" GATE POST TO TURN. PLUMB STEEL POST. TOP OF 6" STEEL POST PLUMB STEEL POST GRADE CONCRETE FOUNDATION MIN. 18" DIA. BY 48" DEEP (CHECK LOCAL BLDG CODE) NOTE: 6" BELOW FROST LINE, BUT NOT LESS THAN 2'-6" BELOW GRADE ch e c k l o c a l b l d g . c o d e 48 " D E E P dia. 1'-6" 6' - 4 " 11 AS-300 21 AS-300 Sim 6 5/8" DIA. STEEL PIPE FILLED WITH CONCRETE, PAINT FREDDY'S BLACK STEEL SLEEVE HINGE, WELD TO GATE MIN. 6" CLEAR BETWEEN GRADE AND BOTTOM OF GATE 13 AS-300 3' - 6 " 6" ALUMINUM WELDED TUBE FRAME WITH PATENT PENDING ALUMINUM BRACKETS WITH PLANE COMPOSITE BEARINGS TO FIT A 6-5/8" OD SCHEDULE 40 GALVANIZED PIPE. TOP BRACKET CLOSED END. APPROXIMATELY 50% LIGHTER THAN TRADITIONAL COMPOSITE GATE DESIGN. INSIDER TO INSIDER BOLLARDS POST HEIGHT FINISHED GATE HEIGHT 6" CLEARANCE BETWEEN GRADE & BOTTOM OF GATE PANEL MATERIAL: COMPOSITE TIMBER GRAY WITH PATENT PENDING REDUCED FASTENER SYSTEM. 100% MAINTENANCE FREE, NO LUBRICATION REQUIRED. NO GUIDE WHEEL REQUIRED. CANE BOLT 106' - 8" TOP OF WALL The Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal. ARCHITECT NAME - ARCHITECT MO# A-XXXXXXX FI L E P A T H : DATE: PROJECT NO: CHECKED BY: DRAWN BY: STORE NO:XXXX Ar c h i t e c t u r e · E n g i n e e r i n g · P l a n n i n g · In t e r i o r D e s i g n · L a n d s c a p e A r c h i t e c t u r e 345 RIVERVIEW, WICHITA, KS 67203 T 316.268.0230 F 316.268.0205 LK Ar c h i t e c t u r e C: \ U s e r s \ j a g u i l e r a \ D o c u m e n t s \ 2 3 2 3 4 _ F r e dd y ' s _ W a u k e e I A _ v 2 2 _ j a g u i l e r a S 6 M W N . r v t TRASH ENCLOSURE PLAN AND DETAILS AS-300 23234 10.06.2023 Checker Fr e d d y ' s F r o z e n C u s t a r d Wa u k e e , I o w a Fr e d d y ' s - F r o z e n C u s t a r d Author 02'3'1'3/4ʺ = 1ʹ‐0ʺ21 STORAGE SHED SECTION 02'3'1'3/4ʺ = 1ʹ‐0ʺ11 TRASH ENCLOSURE WALL SECTION 04'8'2'1/4ʺ = 1ʹ‐0ʺ23 TRASH ENCLOSURE REAR ELEVATION 0 1' 1 1/2'1/2'1 1/2ʺ = 1ʹ‐0ʺ29 ENLARGED SOFFIT & GUTTER DTL. 02'4'1'1/4ʺ = 1ʹ‐0ʺ13 STORAGE SHED SECTION 0 1' 1 1/2'1/2'1 1/2ʺ = 1ʹ‐0ʺ26 ENLARGED SOFFIT DTL. @ HIGH EAVE 0 1' 1 1/2'1/2'1 1/2ʺ = 1ʹ‐0ʺ27 ENLARGED SOFFIT & GUTTER DTL. 0 1' 1 1/2'1/2'1 1/2ʺ = 1ʹ‐0ʺ24 FOOTING DETAIL 0 1' 1 1/2'1/2'1 1/2ʺ = 1ʹ‐0ʺ15 FLASHING DETAIL DESCRIPTION DATE 1 ENLARGED TRASH ENCLOSURE PLAN 4 TRASH ENCLOSURE POST POSITION DETAIL & INSTALLATION 19 TRASH ENCLOSURE FRONT ELEVATION 5 MUELLER DOOR COMPANY COMPOSITE PANEL