Loading...
HomeMy WebLinkAbout2024-03-04 I04 Waukee High School Utilities_Site Plan AGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: March 4, 2024 AGENDA ITEM: Consideration of approval of a resolution approving a site plan for Additions and Renovations to Waukee High School Site Utilities FORMAT: Resolution SYNOPSIS INCLUDING PRO & CON: The applicant is requesting approval of a site plan for additions and renovations to site utilities, located north of SE University Avenue and east of Ashworth Drive. The Waukee Community School District is proposing two phases to the Waukee High School addition project. Phase 1 is to complete the utility work. Phase 2 includes the building addition and parking lot improvements. The site utilities plan includes abandoning existing gas, water, and fiber lines and then installing new lines in order to accommodate for the proposed future expansion of the building. Phase 2 of the project, which includes the building addition and parking lot improvements, will come back as a separate site plan for approval at a later date. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning Commission reviewed the site plan request at their meeting on February 27, 2024 and recommended approval: Approval of a Site Plan for Additions and Renovations to Waukee High School Site Utilities Melissa DeBoer, Planning Coordinator, introduced the request for an addition to the existing Waukee High School building which includes a new auditorium. The school district is proposing two phases to the project. Phase 1 is to complete the utility work, and Phase 2 includes the building addition and parking lot improvements. The proposed plan for the site utilities includes abandoning existing gas, water and fiber lines, installing new lines to accommodate proposed future expansion of the building. Staff recommends approval of the site plan for the additions and renovations to Waukee High School Site Utilities. Discussion as follows: • General discussion of what the site/layout will look like and location of addition on the site as well as parking • Melissa confirmed that current access points will remain the same I4 Motion by Commissioner Streit for approval of the site plan for the additions and renovations to Waukee High School Site utilities, seconded by Commissioner Koelker. Ayes: Streit, Beenken, Koelker, Lohse and Bankole. Nays: None. Motion carried. STAFF REVIEW AND COMMENT: Staff recommends approval of the site plan for Additions and Renovations to Waukee High School Site Utilities subject to remaining staff comments. RECOMMENDATION: Approve the resolutions. ATTACHMENTS: I. Proposed Resolution II. Staff Memo III. Site Plan PREPARED BY: Melissa DeBoer, Planning Coordinator REVIEWED BY: PUBLIC NOTICE INFORMATION – NAME OF PUBLICATION: DATE OF PUBLICATION: THE CITY OF WAUKEE, IOWA RESOLUTION 2024- APPROVING THE SITE PLAN FOR ADDITIONS AND RENOVATIONS TO WAUKEE HIGH SCHOOL SITE UTILITIES IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Site Plan for Additions and Renovations to Waukee High School Site Utilities, subject to remaining staff comments on February 27, 2024; AND, WHEREAS, the Site Plan for Additions and Renovations to Waukee High School Site Utilities is in general conformance with §160 – Site and Building Development Standards Ordinance of the Waukee Municipal Code; AND, WHEREAS, the Site Plan for Additions and Renovations to Waukee High School Site Utilities is in general conformance with §161 – Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND, NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 4th day of March, 2024, that the Site Plan for Additions and Renovations to Waukee High School Site Utilities is approved subject to remaining staff comments. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN R. Charles Bottenberg Chris Crone Rob Grove Anna Bergman Pierce Ben Sinclair M emo Waukee City Hall 230 Highway 6 Waukee IA 50263 Office: (515) 987-4522 Cell: (515) 250-7986 Facsimile: (515) 987-1845 To: Planning and Zoning Commissioners From: Melissa DeBoer, AICP – Planning Coordinator Date: February 23, 2024 Re: Waukee High School – Additions and Renovations to Site Utilities Attach: Proposed Plan for Additions and Renovations to Waukee High School Site Utilities BACKGROUND The Waukee Community School District is proposing an addition to the existing Waukee High School building which includes a new auditorium. The School District is proposing two phases to the project. Phase 1 is to complete the utility work. Phase 2 includes the building addition and parking lot improvements. PROPOSED PLAN The proposed plan for the site utilities includes abandoning existing gas, water, and fiber lines and then installing new lines in order to accommodate for the proposed future expansion of the building. STAFF RECOMMENDATION At this time, staff would recommend approval of the site plan for the Additions and Renovations to Waukee High School Site Utilities. ADDITION AND RENOVATIONS TO WAUKEE HIGH SCHOOL SITE UTILITIES WAUKEE, IOWA IOWAONE CALL 1-800-292-8989 www.iowaonecall.com 811 Know what's below. Call before you dig. PROPERTY DESCRIPTION: THAT PART OF THE EAST ONE-HALF OF THE SOUTHWEST QUARTER (E 1/2 SW 1/4) LYING SOUTH OF THE RIGHT-OF-WAY OF THE MINNEAPOLIS AND ST. LOUIS RAILROAD AND EAST OF HIGHWAY IN SECTION 34, TOWNSHIP 79 NORTH, RANGE 26 WEST OF THE 5TH P.M., IN DALLAS COUNTY, IOWA, CONTAINING 30 ACRES MORE OR LESS, SUBJECT TO EASEMENTS AND RESTRICTIONS OF RECORD. ADDRESS: 555 SE UNIVERSITY AVENUE WAUKEE, IOWA 50263 OWNER/PREPARED FOR: WAUKEE COMMUNITY SCHOOL DISTRICT ATTN: KIRK JOHNSON 560 SE UNIVERSITY AVENUE WAUKEE, IOWA 50263 PHONE: 515-987-5161 EMAIL: KJOHNSON3@WAUKEESCHOOLS.ORG ZONING: A-1 AGRICULTURAL DISTRICT MINIMUM FRONT YARD DEPTH - 35 FEET MINIMUM REAR YARD DEPTH - 35 FEET MINIMUM SIDE YARD DEPTH - 35 FEET MAXIMUM BUILDING HEIGHT - 3 STORIES FOR AN OFFICIAL ZONING REPORT PLEASE CALL CITY OF WAUKEE CITY CLERK AT 515-978-7904 BENCHMARK: BASIS OF BEARING OBTAINED FROM GPS OBSERVATIONS DATUM = NAD 83, IOWA SOUTH BENCHMARK DATUM = NAVD88, GEOID 18 POINT #1, FOUND 1/2 IRON RCP NORTHING = 7493707.33 EASTING = 18459168.94 ELEVATION = 1031.15 DESCRIPTION: NORTHWEST CORNER OF THE SITE APPROXIMATELY 7 FEET NORTH OF THE DOUBLE CMP POINT #2, FOUND CUT X NORTHING = 7492117.04 EASTING = 18459161.24 ELEVATION = 1022.43 DESCRIPTION: SOUTH OF THE TRAFFIC POLE ON THE NORTHEAST CORNER OF INTERSECTION OF SE UNIVERSITY AVENUE AND ASHWORTH ROAD VICINITY MAP NO SCALE COPYRIGHT 2024 BISHOP ENGINEERING. THIS DOCUMENT AND THE INFORMATION CONTAINED MAY NOT BE REPRODUCED OR EXCERPTED WITHOUT THE EXPRESS WRITTEN PERMISSION OF BISHOP ENGINEERING. UNAUTHORIZED COPYING OR DISCLOSURE OF CONSTRUCTION USE ARE PROHIBITED BY COPYRIGHT LAW. SHEET INDEX: C-001 COVER SHEET C-101-102 DEMO PLAN C-401-402 UTILITY PLAN GENERAL NOTES: 1.ALL WORK SHALL BE DONE IN ACCORDANCE WITH 2023 WAUKEE STANDARD SPECS AND 2024 SUDAS. THE CITY OF WAUKEE MUST BE NOTIFIED BY ALL CONTRACTORS 48 HOURS PRIOR TO COMMENCING WORK. 2.IN EVENT OF A DISCREPANCY BETWEEN THE QUANTITY ESTIMATES AND THE DETAILED PLANS, THE DETAILED PLANS SHALL GOVERN. 3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION OF ALL UTILITIES. ANY DAMAGE TO SAID UTILITIES SHALL BE REPAIRED AT THE CONTRACTORS EXPENSE. 4.ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE CURRENT O.S.H.A. CODES AND STANDARDS. NOTHING INDICATED ON THESE PLANS SHALL RELIEVE THE CONTRACTOR FROM COMPLYING WITH THE APPROPRIATE SAFETY REGULATIONS. 5.ALL NECESSARY CONSTRUCTION SIGNS, BARRICADES AND OTHER TRAFFIC CONTROL DEVICES REQUIRED DURING CONSTRUCTION WILL BE FURNISHED BY THE CONTRACTOR. SIGNS, BARRICADES AND OTHER TRAFFIC CONTROL DEVICES MUST BE IN CONFORMANCE WITH THE "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS." 6.BISHOP ENGINEERING SHALL NOT BE LIABLE FOR ANY INJURIES THAT HAPPEN ON SITE. THIS SHALL INCLUDE BUT NOT BE LIMITED TO TRENCH COLLAPSES FROM VARYING SOIL CONDITIONS OR INJURIES CAUSED BY UNDERGROUND UTILITIES INCLUDING UTILITIES THAT ARE NOT SHOWN ON PLAN. 7.THE CONTRACTOR IS LIABLE FOR ALL DAMAGES TO PUBLIC OR PRIVATE PROPERTY CAUSED BY THEIR ACTION OR INACTION IN PROVIDING FOR STORM WATER FLOW DURING CONSTRUCTION. DO NOT RESTRICT FLOWS IN EXISTING DRAINAGE CHANNELS, STORM SEWER, OR FACILITIES. 8.THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER A SCHEDULE FOR PERFORMANCE OF WORK ITEMS. THIS SCHEDULE SHALL BE PROVIDED BY THE CONTRACTOR AT THE PROJECT PRECONSTRUCTION CONFERENCE. NO WORK SHALL BEGIN UNTIL A SCHEDULE HAS BEEN SUBMITTED AND ACCEPTED. THE CONTRACTOR SHALL THEN PERFORM WORK TO CONFORM TO THE ACCEPTED SCHEDULE. 9.LABORATORY TESTS SHALL BE PERFORMED BY THE OWNER UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL PROVIDE SAMPLES OF MATERIAL REQUIRED FOR LABORATORY TESTS AND TESTING IN ACCORDANCE WITH THE URBAN STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS. 10.SOIL IMPORT OR EXPORT ON THIS PROJECT SHALL BE CONSIDERED INCIDENTAL AND WILL NOT BE MEASURED OR PAID FOR SEPARATELY. 11.THE CONTRACTOR SHALL PROTECT ALL STRUCTURES NOT SHOWN AS REMOVALS ON THE PLANS. 12.THE CONTRACTOR SHALL OBTAIN ANY AND ALL NECESSARY PERMITS PRIOR TO ANY CONSTRUCTION. CONTRACTOR SHALL WORK WITH OWNER OR OWNERS REPRESENTATIVE ON ALL REQUIRED STORM WATER DISCHARGE PERMITS FROM THE IOWA DEPARTMENT OF NATURAL RESOURCES AND THE CITY OF WAUKEE. 13.GRADING AND EROSION CONTROL SHALL BE DONE IN ACCORDANCE WITH THE APPROVED GRADING PLAN, SWPPP, NPDES DOCUMENTS, AND IOWA DEPARTMENT OF NATURAL RESOURCES REQUIREMENTS. 14.THE CONTRACTOR SHALL PICK UP ANY DEBRIS SPILLED ONTO THE ADJACENT RIGHT OF WAY OR ABUTTING PROPERTIES AS THE RESULT OF CONSTRUCTION, AT THE END OF EACH WORK DAY AND PRIOR TO A RAIN EVENT. 15.THE CONTRACTOR IS RESPONSIBLE FOR THE PROMPT REMOVAL OF ALL MUD THAT HAS BEEN TRACKED OR WASHED UNTO ADJACENT PROPERTY OR RIGHT OF WAY UNTIL SUCH TIME THAT PERMANENT VEGETATION HAS BEEN ESTABLISHED. 16.DISPOSE OF ALL EXCESS MATERIALS AND TRASH IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL REQUIREMENTS. PROVIDE WASTE AREAS OR DISPOSAL SITES FOR EXCESS MATERIALS NOT DESIRABLE FOR INCORPORATION INTO THE PROJECT. UTILITY NOTES: 1.QUANTITY CALLOUTS ON PIPE LENGTHS ARE APPROXIMATE AND SHOULD BE USED FOR REFERENCE ONLY. 2.THE CONTRACTOR SHALL PROVIDE AS-BUILTS OF ALL UTILITIES, INCLUDING DEPTH AND LOCATION OF ALL SERVICES. 3.THE CONTRACTOR SHALL COORDINATE THE ADJUSTMENT OF ANY AND ALL EXISTING AND PROPOSED UTILITIES TO PROPOSED GRADES. EXISTING UTILITIES SHALL BE RAISED OR LOWERED IN ACCORDANCE WITH THE UTILITY OWNER REQUIREMENTS. ANY NECESSARY ADJUSTMENTS SHALL BE CONSIDERED INCIDENTAL TO CONSTRUCTION. 4.ACTIVE EXISTING FIELD TILES ENCOUNTERED DURING CONSTRUCTION SHALL BE REPAIRED, REROUTED, OR CONNECTED TO PUBLIC OR PRIVATE STORM SEWER TO REMAIN IN SERVICE. 5.WATERMAINS SHALL BE C-900. SIZE OF WATERMAIN AS SHOWN ON PLANS. 6.THRUST BLOCKS SHALL BE INSTALLED AS REQUIRED AND SHALL BE CONSIDERED INCIDENTAL TO WATERMAIN CONSTRUCTION. 7.PROPOSED WATERMAIN SHALL BE PRESSURE TESTED, BACTERIA TESTED AND CHLORINATED. THE FILLING OF THE WATER MAIN SHALL BE DONE BY THE CITY OF WAUKEE. 8.TRACER WIRE SHALL BE ADDED TO ALL WATER MAIN, AND BROUGHT TO THE SURFACE AT EVERY HYDRANT. SITE ACCESS/JOB SITE PROTECTION: 1.CONTRACTOR SHALL COORDINATE WITH OWNER AND ENGINEER PRIOR TO CONSTRUCTION FOR SITE ACCESS. 2.PROTECT ALL WORK AND STAGING AREAS WITH 4' ORANGE CONSTRUCTION FENCING. SITE RESTORATION: 1.TOTAL DISTURBED AREA=0.60 ACRES, THEREFORE NO SWPPP IS REQUIRED 2.CONTRACTOR SHALL PLACE SILT SOCK AT THE EDGES OF ALL DISTURBED AREAS. SILT SOCK SHOULD BE MAINTAINED THROUGHOUT THE PROJECT. 3.CONTRACTOR SHALL SEED ALL DISTURBED AREAS WITH TEMP SEED AS FOLLOWS: SUDAS TYPE 5 TEMPORARY SEED: CANADA WILDRYE APPLIED AT 5 PLS/ACRE GRAIN RYE APPLIED AT 50 LB/ACRE OATS APPLIED AT 50 LB/ACRE SEED PER SUDAS SPECIFICATIONS STAKING NOTES: 1.CONTRACTOR IS REQUIRED TO HAVE ALL STAKING DONE UNDER THE SUPERVISION OF A LICENSED LAND SURVEYOR AND IN COORDINATION WITH THE PROJECT ENGINEER. 2.CONTRACTOR IS REQUIRED TO HAVE ALL STAKING DONE DIRECTLY UNDER THE GENERAL CONTRACTOR BY A SINGLE COMPANY. 3.STAKING DOES NOT RELIEVE CONTRACTOR OF ULTIMATE RESPONSIBILITY TO CONSTRUCT THE PROJECT PER PLAN. DRAWING TITLE: REVISIONS: DRAWING NO.: PROJECT NO.: DATE: 26 0 0 w e s t o w n p a r k w a y , s u i t e 3 4 0 , w e s t d e s m o i n e s , i o w a 5 0 2 6 6 p 5 1 5 . 2 2 3 . 5 1 0 0 f 5 1 5 . 2 2 3 . 7 2 2 6 w w w . f r k - a e . c o m fr k a r c h i t e c t s + e n g i n e e r s AD D I T I O N A N D R E N O V A T I O N S T O WA U K E E H I G H S C H O O L S I T E U T I L I T I E S WA U K E E C O M M U N I T Y S C H O O L D I S T R I C T WA U K E E , I O W A 1018B12A FEBRUARY 2024 35 0 1 1 0 4 t h S t r e e t , U r b a n d a l e , I A 5 0 3 2 2 P h : 5 1 5 - 2 7 6 - 0 4 6 7 BI S H O P E N G I N E E R I N G + L: \ L A N D P R O J E C T S 2 0 2 3 \ 2 3 0 1 1 5 - 2 W A U K E E H I G H S C H O O L A D D I T I O N U T I L I T Y R E L O C A T I O N \ D W G \ C 0 C O V E R . D W G 2/ 1 4 / 2 0 2 4 8 : 0 9 : 3 5 A M UTILITY NOTE: THE LOCATION OF THE UTILITIES INDICATED ON THE PLANS HAVE BEEN TAKEN FROM THE FIELD SURVEY, EXISTING PUBLIC RECORDS, AND PLANS PROVIDED BY OTHERS. SURFACE UTILITY LOCATIONS HAVE BEEN FIELD LOCATED BY BISHOP ENGINEERING, UNLESS OTHERWISE NOTED. ALL UNDERGROUND UTILITY LOCATIONS ARE APPROXIMATE LOCATIONS ONLY. BISHOP ENGINEERING DOES NOT GUARANTEE THE UNDERGROUND LOCATION OF ANY UTILITIES SHOWN. IT SHALL BE THE DUTY OF THE CONTRACTOR TO DETERMINE THE LOCATION AND DEPTH OF ANY UNDERGROUND UTILITIES SHOWN AND IF ANY ADDITIONAL UTILITIES, OTHER THAN THOSE SHOWN ON THE PLANS, MAY BE PRESENT. A REQUEST WAS MADE TO IOWA ONE CALL FOR UTILITY PROVIDERS TO VERIFY, LOCATE, AND MARK THEIR UTILITIES IN THE FIELD. UTILITY MAPS PROVIDED BY: 1. ELECTRIC (MIDAMERICAN / 515-252-6972) 2. STORM AND SANITARY (CITY OF WAUKEE / 515-978-7920) 3. FIBER OPTIC (CONSOLIDATED COMMUNICATIONS / 515-867-4769) 4. FIBER OPTIC (UNITE PRIVATE NETWORKS / 816-425-3556) 5. FIBER OPTIC (WAUKEE COMMUNITY SCHOOL DISTRICT / 515-987-5161) 6. GAS (CITY OF WAUKEE / 515-978-7920) 7. WATER (CITY OF WAUKEE / 515-978-7920) C0.1 - C7.1 ABBREVIATIONS: AC ACRES ASPH ASPHALT BK BOOK CONC CONCRETE D DEEDED DISTANCE EX EXISTING ENCL ENCLOSURE FF FINISHED FLOOR FL FLOW LINE FRAC FRACTIONAL M MEASURED DISTANCE MH MANHOLE OPC ORANGE PLASTIC CAP P PLATTED DISTANCE PG PAGE POB POINT OF BEGINNING POC POINT OF COMMENCEMENT PRA PREVIOUSLY RECORDED AS PUE PUBLIC UTILITY EASEMENT ROW RIGHT OF WAY RPC RED PLASTIC CAP SF SQUARE FEET SAN SANITARY TYP TYPICAL YPC YELLOW PLASTIC CAP N NORTH S SOUTH E EAST W WEST ELECTRIC VAULT TRANSFORMER POLE TRANSFORMER POLE LIGHT POLE ELECTRIC JUNCTION BOX ELECTRIC PANEL TRANSFORMER GROUND LIGHT GUY WIRE ELECTRIC HANDHOLE GAS METER GAS VALVE AIR CONDITIONING UNIT TELEPHONE RISER TELEPHONE VAULT TELEPHONE MANHOLE TRAFFIC SIGNAL MANHOLE FIBER OPTIC MANHOLE FIBER OPTIC RISER FIBER OPTIC VAULT CABLE TV RISER SIGN BOLLARDS 7 DENOTES NUMBER OF PARKING STALLS PROPERTY CORNER - FOUND AS NOTED PROPERTY CORNER- PLACED 5/8" IRON ROD WITH YELLOW PLASTIC CAP ID # XXXXX OR AS NOTED SECTION CORNER - FOUND AS NOTED SITE CONTROL POINT - MONUMENT AS NOTED ELEC EJ EP GM GV A/C T TEL T TS FO F/O TV F/O SAN SANITARY SEWER ST STORM SEWER W WATER LINE G GAS LINE U/E UNDERGROUND ELECTRIC O/E OVERHEAD ELECTRIC TELE TELEPHONE LINE F/O FIBER OPTIC CATV CABLE TV STORM MANHOLE CURB INTAKE SURFACE INTAKE FLARED END SECTION ROOF DRAIN DOWNSPOUT SANITARY MANHOLE CLEANOUT FIRE HYDRANT SPRINKLER IRRIGATION CONTROL VALVE WATER MANHOLE WELL WATER VALVE WATER SHUT OFF YARD HYDRANT FLAGPOLE ELECTRIC MANHOLE ELECTRIC METER ELECTRIC RISER D S CO H Y D I CV W WS O YA DR E EM E W WV LEGEND C-001 COVER SHEET SITE SPECIFICATIONS NOTES: 1.ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE ADDITION AND RENOVATIONS TO WAUKEE HIGH SCHOOL SITE UTILITIES PROJECT SPECIFICATIONS, THE CITY OF WAUKEE SPECIFICATIONS AND SUDAS SPECIFICATIONS. 2.FOR ANY DISCREPANCIES BETWEEN THE ADDITION AND RENOVATION TO WAUKEE HIGH SCHOOL SITE UTILITIES PROJECT SPECIFICATIONS AND THE CURRENT EDITION OF IOWA SUDAS, THE PROJECT SPECIFICATIONS SHALL GOVERN UNLESS DIRECTED OTHERWISE BY THE CITY OF WAUKEE OR THE PROJECT ENGINEER. 3.FOR ALL SPECIFICATION DISCREPANCIES, PROJECT ENGINEER SHALL BE CONTACTED PRIOR TO PROCEEDING WITH CONSTRUCTION. IF ENGINEER IS NOT CONTACTED, CONTRACTOR SHALL BE RESPONSIBLE FOR ANY PROBLEMS THAT RESULT FROM SAID DISCREPANCIES. 4.FOR ALL SPECIFICATION DISCREPANCIES, CONTRACTOR MUST OBTAIN WRITTEN APPROVAL FROM THE CITY OF WAUKEE ENGINEERING DEPARTMENT FOR ANY CHANGES TO PROPOSED SITE INFRASTRUCTURE OR GRADES PRIOR TO PROCEEDING WITH ANY CHANGES. ELECTRICAL LINE NOTES: 1.SITE ELECTRICAL LINES SERVICING PARKING LOT AND OTHER LIGHTING ARE SHOWN FOR CONTRACTOR REFERENCE. 2.ELECTRICAL LINES ARE VARYING DEPTH FROM JUST UNDER THE PAVING TO A FEW FEET DEEP. 3.CONTRACTOR RESPONSIBLE FOR PROTECTING ALL ELECTRICAL LINES SHOWN ON PLANS OR MARKED OUT IN THE FIELD. 4.ANY LINES HIT BY THE CONTRACTOR THAT ARE SHOWN ON THE PLANS OR THROUGH FIELD LOCATES ARE THE RESPONSIBILITY OF THE CONTRACTOR TO FIX AND ARE NOT ELIGIBLE FOR A CHANGE ORDER. UTILITY CONFLICT NOTES: 1.UTILITY CONFLICTS MAY EXIST ACROSS THE SITE WITH NEW UTILITIES, GRADING, PAVING ETC. MOST UTILITY CONFLICTS HAVE BEEN CALLED OUT FOR CONTRACTOR CONVENIENCE. 2.CONTRACTOR IS RESPONSIBLE FOR ALL UTILITY CONFLICTS THAT ARE EITHER CALLED OUT ON THE PLANS OR THAT CAN BE SEEN ON THE PLANS BETWEEN AN EXISTING UTILITY AND PROPOSED CONSTRUCTION SURVEY NOTES: 1.SURVEY WORK WAS COMPLETED BY BISHOP ENGINEERING ON 11-06-2023. SE UNIVERSITY AVE AS H W O R T H D R I V E 6T H S T R E E T HICKMAN ROAD EX 18" RCP FES FL=1022.42 CP #9000 6" TREE 6" TREE 6" TREE 6" TREE 8" TREE 24" TREE 8" TREE 8" TREE 6" TREE 6" TREE 8" PINE 8" PINE 8" PINE 24" TREE WV H Y D TBM: BURY BOLT ELEV=1027.39 EX 32" RCP FES FL=1022.59 EX 32" RCP FES FL=1022.81 GV EX INTAKE T/C=1025.74 RIM=1025.32 FL(N 18"RCP)=1022.19 FL(E 12"RCP)=1022.18 FL(S 18"RCP)=1022.08 EX 6" CPP FL=1023.24 EX INTAKE RIM=1024.19 FL(S 18"RCP)=1020.64 FL(N 18"RCP)=1020.60 F/ O F/ O F/ O F/ O F/ O ST 18 " AS H W O R T H D R I V E (P U B L I C S T R E E T - C O N C R E T E S U R F A C E ) 8 10 13 13 13 13 13 13 PRI V A T E D R I V E (C O N C R E T E S U R F A C E ) ST ST 9 9 9 9 EX. "T" POST EX. METAL GUARDRAIL (TYP.) SPEED TABLE WARNING SIGN "STOP" SIGN (TYP.) O/ E O/ E O/ E O/ E O/ E O/ E O/ E O/ E O/ E O/ E O/ E SPEED TABLE (TYP.) EX. A S P H A L T T R A I L EX. A S P H A L T T R A I L EX. A S P H A L T T R A I L EX. C O N C R E T E T R A I L EX. CONCRETE TRAIL EX. A S P H A L T T R A I L RAISED STOOP AND ENTRYWAY EX. CONCRETE PARKING LOT EX . C O N C R E T E P A R K I N G L O T ST 12" ST 12" ST 12" ST 12" ST 12" ST 42 " ST 42 " ST 42 " ST 42 " ST 42 " ST 42 " ST 42 " ST 42 " ST 42 " ST 18 " ST 18 " ST 18 " ST 18 " ST 18 " ST 18 " ST 18 " ST 18 " ST 18 " ST 18" ST 18" ST 18" ST 18" APPROX. LOCATION PER CITY GIS F/ O F/ O F/ O F/ O F/ O F/ O F/ O F / O F / O F/ O F/ O F/ O F/ O F/ O F/ O F/ O F/ O F/ O F/O F/O "STUDENT ONLY PARKING" SIGN (TYP.) "STUDENT ONLY PARKING" SIGN (TYP.) "STUDENT ONLY PARKING" SIGN (TYP.) "NO UNAUTHORIZED PARKING" SIGN (TYP.) EX. BOLLARD (TYP.) F/ O EX. P R A C T I C E F I E L D U/E U/E U/E U/E U/E U/E U/E U/EU/EU/E U/E U/E U/E W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8"W12 " W12 " W12 " W 12 " W 12 " W 12 " W12 " W12 " W12 " W12 " W 12 " W 12 " W 12 " W 12 " W12 " W8"W8"W8" G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G 10 3 0 1 0 2 5 10 2 5 10 2 8 10 2 5 10 2 5 10 2 7 10 2 6 10 2 3 1 0 2 7 10 2 8 1029 1028 1027 1028 102 7 102 6 10 2 7 102 8 1029 8" TREE 4" TREE 14" TREE 14" TREE 6" TREE 12" TREE 12" TREE 6" TREE 6" TREE 6" TREE 6" TREE 6" TREE 6" OAK 1 0 2 7 1028 10 2 8 1 0 2 8 10 2 8 1 0 2 7 10 2 8 1 0 2 8 1 0 2 7 10 3 1 10 2 9 10 2 8 10 2 7 1 0 2 6 1 0 2 5 1025 1 0 2 4 1 0 2 4 102 6 EX . C O N C R E T E P A R K I N G L O T EX . C O N C R E T E P A R K I N G L O T EX . C O N C R E T E P A R K I N G L O T WV H Y D TBM: BURY BOLT ELEV=1023.83 U/E 42 " ST 42 " ST 42 " ST 42 " ST 42 " ST 42 " ST 42 " 10' E L E C E A S E M E N T BK 2 0 0 0 P G 4 7 1 5 U/E U/E U/E U/E U/E U/E U/ E U/ E U/ E U/ E U/ E U/E F/O F/O F/O F/O F/O F/O F/O F/O F/O F/O F/ O F/O F/O F/O F/O WATER LOCATION PER POTHOLING TOP OF WATER=1019.56 FL=1018.45± WV BEGIN 8" WATER ABANDONMENT APPROXIMATE LOCATION OF VALVE #1 MA T C H L I N E MA T C H L I N E BEGIN FIBER ABANDONMENT BEGIN GAS ABANDONMENT CONTRACTOR TO COORDINATE ABANDONMENT OF GAS W/ THE CITY OF WAUKEE ABANDON FIBER CONDUIT (SEE TELECOMMUNICATION PLANS) CONTRACTOR TO DISCONNECT 8" WATER AND ABANDON IN PLACE ABANDON ELEC EASEMENT (BY OTHERS) REMOVE GAS VALVE (BY CITY) DRAWING TITLE: REVISIONS: DRAWING NO.: PROJECT NO.: DATE: 26 0 0 w e s t o w n p a r k w a y , s u i t e 3 4 0 , w e s t d e s m o i n e s , i o w a 5 0 2 6 6 p 5 1 5 . 2 2 3 . 5 1 0 0 f 5 1 5 . 2 2 3 . 7 2 2 6 w w w . f r k - a e . c o m fr k a r c h i t e c t s + e n g i n e e r s AD D I T I O N A N D R E N O V A T I O N S T O WA U K E E H I G H S C H O O L S I T E U T I L I T I E S WA U K E E C O M M U N I T Y S C H O O L D I S T R I C T WA U K E E , I O W A 1018B12A FEBRUARY 2024 35 0 1 1 0 4 t h S t r e e t , U r b a n d a l e , I A 5 0 3 2 2 P h : 5 1 5 - 2 7 6 - 0 4 6 7 BI S H O P E N G I N E E R I N G + GRAPHIC SCALE 020 10 20 40 L: \ L A N D P R O J E C T S 2 0 2 3 \ 2 3 0 1 1 5 - 2 W A U K E E H I G H S C H O O L A D D I T I O N U T I L I T Y R E L O C A T I O N \ D W G \ C 1 D E M O . D W G 2/ 1 4 / 2 0 2 4 8 : 0 9 : 4 4 A M C-101 DEMO PLAN DEMO NOTES: 1.SAWCUT & REMOVE ALL PAVEMENT TO FULL DEPTH OF SLAB. 2.PROTECT ALL TREES NOT CALLED OUT FOR REMOVAL WITH ORANGE CONSTRUCTION FENCE AT THE DRIP LINE. 3.PRIOR TO REMOVING TEE IN 8" WATER, VALVES #1, 2 AND 3 SHALL BE TURNED OFF. WATER REMOVAL NOTES: CONTRACTOR TO PLAN WATER REMOVAL WORK FOR EITHER A NIGHT OR A WEEKEND. CONTRACTOR RESPONSIBLE FOR COORDINATING TIME AND DATE WITH THE SCHOOL DISTRICT. WATER CAN ONLY BE TURNED OFF FOR A MAXIMUM OF 4 HOURS AT A TIME. THE FOLLOWING STEPS SHALL BE TAKEN: 1.CONTRACTOR TO TURN OFF VALVES 1, 2 AND 3. 2.CONTRACTOR TO DISCONNECT SECTION OF WATER TO BE ABANDONED AND INSTALL TEE AND VALVE FOR NEW SECTION OF WATER. 3.ONCE OLD CONNECTION IS REMOVED AND NEW CONNECTION IS INSTALLED ON EAST END, TURN BACK ON VALVES 2 AND 3 WHILE LEAVING VALVE 1 AND THE NEW VALVE CLOSED 4.WITHIN 72 HOURS CONNECT WEST END OF NEW WATER TO EXISTING WATER AND TURN BACK ON VALVE 1 AND THE NEW VALVE. COCO CO MH EX SAN MH RIM=1031.71 MH EX SAN MH RIM=1031.75 MH EX SAN MH RIM=1031.79 MH EX SAN MH RIM=1031.81 COCO WV H Y D TBM: BURY BOLT ELEV=1031.50 WV WV EMEP GM EX 18" RCP FES FL=1022.42 CP #9001 6" TREE 6" TREE 24" TREE 8" TREE 8" TREE EX INTAKE T/C=1025.74 RIM=1025.32 FL(N 18"RCP)=1022.19 FL(E 12"RCP)=1022.18 FL(S 18"RCP)=1022.08 EX INTAKE T/C=1028.19 RIM=1027.51 FL(E 12"RCP)=1023.71 FL(W 12"RCP)=1023.66 EX INTAKE T/C=1028.85 RIM=1028.17 FL(W 12"RCP)=1025.27 ELEC WV EX INTAKE RIM=1024.19 FL(S 18"RCP)=1020.64 FL(N 18"RCP)=1020.60 FF=1032.55 FF = 1 0 3 2 . 5 2 FF = 1 0 3 2 . 5 9 FF= 1 0 3 2 . 6 0 FF=1032.58 FF=1032.62 EXISTING BUILDING WAUKEE HIGH SCHOOL 555 SE UNIVERSITY AVENUE ST 18 " 8 10 13 13 13 13 13 6 GARAGE DOOR EX. TRASH ENCLOSURE 5' BLOCK WALL AND 5' CHAIN LINK ACCESS GATE EX. C O N C R E T E S I D E W A L K EX. METAL GUARDRAIL (TYP.) EX. METAL GUARDRAIL (TYP.) EX. METAL GUARDRAIL (TYP.) EX. CONCRETE STOOP(X2) EX. CONCRETE TRAIL SPEED TABLE (TYP.) SPEED TABLE (TYP.) EX. C O N C R E T E T R A I L EX. A S P H A L T T R A I L EX. A S P H A L T T R A I L EX. A S P H A L T T R A I L EX. C O N C R E T E T R A I L EX . C O N C . EN T R Y W A Y EX . C O N C R E T E S I D E W A L K EX . C O N C R E T E S I D E W A L K EX. C O N C R E T E S I D E W A L K BUILDING ENTRY RAISED STOOP AND ENTRYWAY RAISED STOOP AND ENTRYWAY EX. CONCRETE PARKING LOT ST 12" ST 12" ST 12" ST 12" ST 12" ST 12" ST 12" ST 12" ST 12" ST 12" ST 12" ST 18 " ST 18 " ST 18 " ST 18 " APPROX. LOCATION PER CITY GIS U/E U/E U/E U/E U/E U/E U/E U/E APPROX. LOCATION PER WCSD MAP APPROX. LOCATION PER WCSD MAP "STUDENT ONLY PARKING" SIGN (TYP.) "STUDENT ONLY PARKING" SIGN (TYP.) "STUDENT ONLY PARKING" SIGN (TYP.) "DO NOT ENTER" SIGN (X2) SPEED TABLE WARNING SIGN (X2) EX. BOLLARD (TYP.) SPEED LIMIT SIGN X 3 STEPS TO ENTRY BY GARAGE EX. GOAL POST U/E U/E U/E U/E U/EU/EU/E U/E U/E U/E EX. GOAL POST W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W W 8" W 8" G G G G G G G G G G G G G G G G G G 10 2 5 102 6 10 2 7 102 8 1029 1030 1031 1028 10 3 0 1030 10 3 0 1029 1 0 3 0 1 0 3 1 1 0 3 2 1033 14" TREE 6" TREE 12" TREE 12" TREE 6" TREE 6" TREE 6" TREE 6" TREE 6" TREE 6" TREE H Y DHYD TBM: BURY BOLT ELEV=1030.01 WV 6" OAK 1 0 3 3 1032 1033 1032 103 1 1 0 3 3 103 3 1 0 3 3 10 3 3 10 3 2 10 3 1 1 0 3 2 10 2 9 10 2 8 10 2 7 1 0 2 6 1 0 2 5 1 0 2 4 1 0 2 4 102 6 EX . C O N C R E T E P A R K I N G L O T EX . C O N C R E T E P A R K I N G L O T EX GI CLEANOUT FL=1026.40 EX GI CLEANOUT FL=1026.48 U/E G G G U/ E U/ E U/E U/E U/E U/E U/E U/E G U/ E U/ E U/E U / E U / E U/E U/E U/E U/E U/E U/E U/E U/E U/EU/E U/E U/E U/E U/E U/E U / E U/E 10 ' E L E C E A S E M E N T BK 2 0 0 0 P G 4 7 1 5 U/ E U/ E U/ E U/ E U/E F/O F/O SA N SA N F/ O F / O F / O F/ O F/O F/O F/O F/O F/O F/O F/O F/O F/O F/O BEGIN 8" WATER ABANDONMENT DISCONNECT WATER, REMOVE TEE AND SEE NOTES ON SHEET C-101 PROTECT GAS METER IN PLACE PROTECT HYDRANT PROTECT TRANSFORMER KEEP ELEC EASEMENT VALVE #2 VALVE #3 APPROXIMATELY 410 FEET NORTH OF VALVE #2 ALONG 8" WATER LINE MA T C H L I N E MA T C H L I N E CONTRACTOR TO COORDINATE ABANDONMENT OF GAS W/ THE CITY OF WAUKEE PROTECT LIGHT POLES AND LINES PROTECT EX LIGHT POLES AND LINES PROTECT LIGHT POLES AND LINES ABANDON ELEC EASEMENT (BY OTHERS) END OF FIBER ABANDONMENT END OF GAS ABANDONMENT CONTRACTOR TO DISCONNECT 8" WATER AND ABANDON IN PLACE REMOVE SIDEWALK ABANDON ELEC EASEMENT (BY OTHERS) END OF GAS ABANDONMENT (BY CITY OF WAUKEE GAS) CONTRACTOR TO COORDINATE ABANDONMENT OF GAS W/ THE CITY OF WAUKEE REMOVE TRAIL ABANDON FIBER CONDUIT (SEE TELECOMMUNICATION PLANS) DRAWING TITLE: REVISIONS: DRAWING NO.: PROJECT NO.: DATE: 26 0 0 w e s t o w n p a r k w a y , s u i t e 3 4 0 , w e s t d e s m o i n e s , i o w a 5 0 2 6 6 p 5 1 5 . 2 2 3 . 5 1 0 0 f 5 1 5 . 2 2 3 . 7 2 2 6 w w w . f r k - a e . c o m fr k a r c h i t e c t s + e n g i n e e r s AD D I T I O N A N D R E N O V A T I O N S T O WA U K E E H I G H S C H O O L S I T E U T I L I T I E S WA U K E E C O M M U N I T Y S C H O O L D I S T R I C T WA U K E E , I O W A 1018B12A FEBRUARY 2024 35 0 1 1 0 4 t h S t r e e t , U r b a n d a l e , I A 5 0 3 2 2 P h : 5 1 5 - 2 7 6 - 0 4 6 7 BI S H O P E N G I N E E R I N G + GRAPHIC SCALE 020 10 20 40 L: \ L A N D P R O J E C T S 2 0 2 3 \ 2 3 0 1 1 5 - 2 W A U K E E H I G H S C H O O L A D D I T I O N U T I L I T Y R E L O C A T I O N \ D W G \ C 1 D E M O . D W G 2/ 1 4 / 2 0 2 4 8 : 0 9 : 4 8 A M C-102 DEMO PLAN EX 18" RCP FES FL=1022.42 CP #9000 WV H Y D TBM: BURY BOLT ELEV=1027.39 EX 32" RCP FES FL=1022.59 EX 32" RCP FES FL=1022.81 GV EX INTAKE T/C=1025.74 RIM=1025.32 FL(N 18"RCP)=1022.19 FL(E 12"RCP)=1022.18 FL(S 18"RCP)=1022.08 EX 6" CPP FL=1023.24 EX INTAKE RIM=1024.19 FL(S 18"RCP)=1020.64 FL(N 18"RCP)=1020.60 F/ O F/ O F/ O F/ O F/ O FF=1032.58 ST 18 " AS H W O R T H D R I V E (P U B L I C S T R E E T - C O N C R E T E S U R F A C E ) 8 10 13 13 13 13 13 13 PRI V A T E D R I V E (C O N C R E T E S U R F A C E ) ST ST 9 9 9 9 EX. "T" POST EX. METAL GUARDRAIL (TYP.) EX. METAL GUARDRAIL (TYP.) SPEED TABLE WARNING SIGN "STOP" SIGN (TYP.) O/ E O/ E O/ E O/ E O/ E O/ E O/ E O/ E O/ E O/ E O/ E SPEED TABLE (TYP.) EX. A S P H A L T T R A I L EX. A S P H A L T T R A I L EX. A S P H A L T T R A I L EX. C O N C R E T E T R A I L EX. CONCRETE TRAIL EX. A S P H A L T T R A I L RAISED STOOP AND ENTRYWAY RAISED STOOP AND ENTRYWAY EX. CONCRETE PARKING LOT EX . C O N C R E T E P A R K I N G L O T ST 12" ST 12" ST 12" ST 12" ST 12" ST 42 " ST 42 " ST 42 " ST 42 " ST 42 " ST 42 " ST 42 " ST 42 " ST 42 " ST 42 " ST 18 " ST 18 " ST 18 " ST 18 " ST 18 " ST 18 " ST 18 " ST 18 " ST 18 " ST 18" ST 18" ST 18" ST 18" F/ O F/ O F/ O F/ O F/ O F/ O F/ O F / O F/ O F/ O F/ O F/ O F/ O F/ O F / O F/ O F/ O F/ O F/ O F/O F/O "STUDENT ONLY PARKING" SIGN (TYP.) "STUDENT ONLY PARKING" SIGN (TYP.) "STUDENT ONLY PARKING" SIGN (TYP.) "DO NOT ENTER" SIGN (X2) "NO UNAUTHORIZED PARKING" SIGN (TYP.) EX. BOLLARD (TYP.) F/ O EX. P R A C T I C E F I E L D U/E U/E U/E U/E U/E U/E U/E U/EU/EU/E U/E U/E U/E W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8"W12 " W12 " W12 " W 12 " W 12 " W 12 " W12 " W12 " W12 " W12 " W 12 " W 12 " W 12 " W 12 " W12 " W8"W8"W8" G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G EX . C O N C R E T E P A R K I N G L O T EX . C O N C R E T E P A R K I N G L O T EX . C O N C R E T E P A R K I N G L O T U/E WV H Y D TBM: BURY BOLT ELEV=1023.83 U/E ST 42 " ST 42 " ST 42 " ST 42 " ST 42 " ST 42 " 10' E L E C E A S E M E N T BK 2 0 0 0 P G 4 7 1 5 U/E U/E U/E U/E U/E U/E U/ E U/ E U/ E U/ E U/ E U/E F/O F/O F/O F/O F/O F/O F/O F/O F/ O F/O F/ O F/O F/O F/O F/O F/O WATER LOCATION PER POTHOLING TOP OF WATER=1019.56 FL=1018.45± WV MA T C H L I N E MA T C H L I N E W 8" W 8" 90° BEND 76LF 8" WATER G 2" G 2" G2" G2" G2" G2"G2" G 2" G 2" G2" G2" G 2" G2" G2" G U/E U/E U/E U/E U/EU/E U/E U/E U/E U/E U/E U/E U/E F/O F/O F/O F/O F/O F/O F/O F/O F/O F/O F/O F/O F/O F/O CONNECT TO EX WATER AND REMOVE EX BEND 6"X8" TEE U/E 0+ 0 0 WV NEW 8" VALVE CONNECT TO EX FIBER GAS LINE SHOWN FOR REFERENCE ONLY. CONTRACTOR TO COORDINATE RELOCATION OF GAS LINE W/ CITY OF WAUKEE CONNECT TO EX ELECTRIC CONNECT TO EX GAS EX GAS AND FIBER TO BE ABANDONED IN PLACE CONTRACTOR TO INSTALL 942LF-4" CONDUIT FOR FOR FUTURE MIDAM USE FUTURE STORM CRITICAL CROSSING BEND FIBER, GAS AND ELEC UNDER FUTURE STORM TOP OF STORM=1024.83 BOTTOM OF STORM=1023.24 EX GRADE=1028.33 FUTURE PROPOSED GRADE=1027.93 TOP OF CONDUIT=1022.24 FUTURE STORM CRITICAL CROSSING BEND FIBER, GAS AND ELEC UNDER FUTURE STORM TOP OF STORM=1026.13 BOTTOM OF STORM=1022.46 EX GRADE=1027.00 FUTURE PROPOSED GRADE=1028.83 TOP OF CONDUIT=1021.46 FIBER LINE (SEE TELECOMMUNICATION PLAN) DRAWING TITLE: REVISIONS: DRAWING NO.: PROJECT NO.: DATE: 26 0 0 w e s t o w n p a r k w a y , s u i t e 3 4 0 , w e s t d e s m o i n e s , i o w a 5 0 2 6 6 p 5 1 5 . 2 2 3 . 5 1 0 0 f 5 1 5 . 2 2 3 . 7 2 2 6 w w w . f r k - a e . c o m fr k a r c h i t e c t s + e n g i n e e r s AD D I T I O N A N D R E N O V A T I O N S T O WA U K E E H I G H S C H O O L S I T E U T I L I T I E S WA U K E E C O M M U N I T Y S C H O O L D I S T R I C T WA U K E E , I O W A 1018B12A FEBRUARY 2024 35 0 1 1 0 4 t h S t r e e t , U r b a n d a l e , I A 5 0 3 2 2 P h : 5 1 5 - 2 7 6 - 0 4 6 7 BI S H O P E N G I N E E R I N G + L: \ L A N D P R O J E C T S 2 0 2 3 \ 2 3 0 1 1 5 - 2 W A U K E E H I G H S C H O O L A D D I T I O N U T I L I T Y R E L O C A T I O N \ D W G \ C 4 U T I L I T Y . D W G 2/ 1 4 / 2 0 2 4 8 : 0 9 : 5 7 A M GRAPHIC SCALE 020 10 20 40 C-401 UTILITY PLAN COCO CO MH EX SAN MH RIM=1031.71 MH EX SAN MH RIM=1031.75 MH EX SAN MH RIM=1031.79 MH EX SAN MH RIM=1031.81 COCO WV H Y D TBM: BURY BOLT ELEV=1031.50 WV WV EMEP GM EX 18" RCP FES FL=1022.42 CP #9001 EX INTAKE T/C=1028.19 RIM=1027.51 FL(E 12"RCP)=1023.71 FL(W 12"RCP)=1023.66 EX INTAKE T/C=1028.85 RIM=1028.17 FL(W 12"RCP)=1025.27 ELEC WV FF = 1 0 3 2 . 5 2 FF = 1 0 3 2 . 5 9 FF= 1 0 3 2 . 6 0 FF=1032.58 FF=1032.62 EXISTING BUILDING WAUKEE HIGH SCHOOL 555 SE UNIVERSITY AVENUE ST 18 " 8 10 13 13 13 6 GARAGE DOOR EX. TRASH ENCLOSURE 5' BLOCK WALL AND 5' CHAIN LINK ACCESS GATE EX. C O N C R E T E S I D E W A L K EX. METAL GUARDRAIL (TYP.) EX. METAL GUARDRAIL (TYP.) EX. METAL GUARDRAIL (TYP.) EX. CONCRETE STOOP(X2) EX. CONCRETE TRAIL SPEED TABLE (TYP.) EX. C O N C R E T E T R A I L EX. A S P H A L T T R A I L EX. A S P H A L T T R A I L EX . C O N C R E T E S I D E W A L K EX . C O N C R E T E S I D E W A L K EX. C O N C R E T E S I D E W A L K BUILDING ENTRY RAISED STOOP AND ENTRYWAY RAISED STOOP AND ENTRYWAY EX. CONCRETE PARKING LOT ST 12" ST 12" ST 12" ST 12" ST 12" ST 12" ST 12" ST 12" ST 12" ST 12" ST 12" U/E U/E U/E U/E U/E U/E "STUDENT ONLY PARKING" SIGN (TYP.) "STUDENT ONLY PARKING" SIGN (TYP.) "DO NOT ENTER" SIGN (X2) SPEED TABLE WARNING SIGN (X2) EX. BOLLARD (TYP.) X 3 STEPS TO ENTRY BY GARAGE EX. GOAL POST U/EU/EU/E U/E U/E U/E EX. GOAL POST W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" G G G G G G G G G G G G G G H Y DHYD TBM: BURY BOLT ELEV=1030.01 EX . C O N C R E T E P A R K I N G L O T EX GI CLEANOUT FL=1026.40 EX GI CLEANOUT FL=1026.48 U/E G G G U/ E U/ E U/E U/E U/E U/E G U/ E U/ E U/E U / E U / E U/E U/ E U/E U/E U/E U/E U/E U/E U/EU/E U/E U/E U/E U/E U/E U / E U/E 10 ' E L E C E A S E M E N T BK 2 0 0 0 P G 4 7 1 5 U/ E U/ E U/E SA N SA N F/ O F / O F / O F/ O F/O F/O F/O F/O F/O F/O F/O F/O F/O F/O MA T C H L I N E MA T C H L I N E W 8" W 8" W8" W 8" W8" W8" W8" W 8" W 8" W8" W8" G 2" G 2" G2" CONNRECT TO EX 8" WATER W/ TS&V CITY OF WAUKEE STANDARDS 303LF 8" WATER 90° BEND 76LF 8" WATER G 2" G2" G2" G 2" G2" G2" G2" G 2" G 2" G2" G2" G 2" G2" G2" G2" G2" G2" G2" G2" U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E F/O F/O F/O F/O F/O F/O F/O F/O F/O F/O F/O F/O F/O F/O F/O F/O F/O F/O F/O CONNECT TO EX WATER AND REMOVE EX BEND 20LF 6" WATER 6"X8" TEE HY D INSTALL HYDRANT ASSEMBLY EX GRADE=1027.50 FUTURE PROPOSED GRADE=1029.50 EX FDC 0+ 0 0 1+00 2+00 3+00 3+78. 8 1 WV NEW 8" VALVE F/O F/O WV GAS LINE SHOWN FOR REFERENCE ONLY. CONTRACTOR TO COORDINATE RELOCATION OF GAS LINE W/ CITY OF WAUKEE GAS LINE SHOWN FOR REFERENCE ONLY. CONTRACTOR TO COORDINATE RELOCATION OF GAS LINE W/ CITY OF WAUKEE FOR INSTALLATION. GAS LINE TO BE INSTALLED IMMEDIATELY AFTER CONDUITS ARE INSTALLED. FIBER LINE (SEE TELECOMMUNICATION PLAN) CONNECT TO EX GAS CONNECT TO EX GAS (BY CITY) TERMINATE 4" CONDUIT INTO TRANSFORMER (SEE NOTES) NEW UTILITES ARE TO BE BORED UNDER EXISTING ROAD, WATERMAIN AND TRAIL FUTURE WATER X STORM CRITICAL CROSSING TOP OF STORM=1026.81± BOTTOM OF STORM=1024.90± TOP OF WATER=1022.90± FUTURE WATER X STORM CRITICAL CROSSING POTHOLE WATER ELEVATION AND REPORT TO BISHOP ENGINEERING BY APRIL 3, 2024 FUTURE WATER X STORM CRITICAL CROSSING TOP OF STORM=1026.21± BOTTOM OF STORM=1024.87± TOP OF WATER=1022.87± EX GAS, FIBER AND WATER TO BE ABANDONED IN PLACE 4"-45° FIBERGLASS SWEEPS ON MIDAM CONDUIT (SEE SPEC 33 71 73) *CRITICAL CROSSING* FIBER, ELECTRIC AND GAS OVER NEW WATERMAIN FUTURE STORM CRITICAL CROSSING BEND FIBER, GAS AND ELEC UNDER FUTURE STORM TOP OF STORM=1027.08 BOTTOM OF STORM=1025.16 EX GRADE=1032.96 FUTURE PROPOSED GRADE=1030.04 TOP OF CONDUIT=1024.16 BEND FIBER, GAS AND ELEC UNDER FUTURE STORM TOP OF STORM=1024.83 BOTTOM OF STORM=1023.24 EX GRADE=1028.33 FUTURE PROPOSED GRADE=1027.93 TOP OF CONDUIT=1022.24 FIBER PULL BOX (SEE TELECOMMUNICATION PLAN) FIBER PULL BOX (SEE TELECOMMUNICATION PLAN) **CRITICAL CROSSING** PROTECT EX ELECTRIC **CRITICAL CROSSING** PROTECT EX GAS DURING CONDUIT INSTALL **CRITICAL CROSSING** PROTECT EX ELECTRIC 4"-90° FIBERGLASS SWEEPS ON MIDAM CONDUIT (SEE SPEC 33 71 73) TERMINATE 4" CONDUITS ABOVE GROUND AND CAP PER MIDAM STANDARDS AT SITE OF FUTURE TRANSFORMER **CRITICAL CROSSING** PROTECT EX ELECTRIC INSTALL NEW CONDUITS UNDER EXISTING ELECTRIC CONTRACTOR TO INSTALL 108LF-4" CONDUIT FOR FOR FUTURE MIDAM USE INSTALL NEW 8" VALVE AT LOCATION OF ABANDONED WATER LINE HEADING WEST AND RECONNECT WATER WV WATER 1015 1020 1025 1030 1035 1040 1045 1015 1020 1025 1030 1035 1040 1045 -0+50 0+00 1+00 2+00 3+00 4+00 4+50 CONNECT TO EX 8" WATER 8" WATER 8" WATER CONNECT TO EX WATER W/ TS&V EXISTING GROUND PROFILE FUTURE PROPOSED GROUND PROFILE *CRITICAL CROSSING* BOTTOM OF STORM=1024.87 TOP OF WATER=1022.87 *CRITICAL CROSSING* BOTTOM OF STORM=1024.90 TOP OF WATER=1022.90 6' M I N D E P T H FR O M P G 6 ' M I N D E P T H F R O M P G 18" STORM 12" STORM EXISTING GROUND PROFILE FUTURE PROPOSED GROUND PROFILE GAS FIBER ELEC EX ELEC DRAWING TITLE: REVISIONS: DRAWING NO.: PROJECT NO.: DATE: 26 0 0 w e s t o w n p a r k w a y , s u i t e 3 4 0 , w e s t d e s m o i n e s , i o w a 5 0 2 6 6 p 5 1 5 . 2 2 3 . 5 1 0 0 f 5 1 5 . 2 2 3 . 7 2 2 6 w w w . f r k - a e . c o m fr k a r c h i t e c t s + e n g i n e e r s AD D I T I O N A N D R E N O V A T I O N S T O WA U K E E H I G H S C H O O L S I T E U T I L I T I E S WA U K E E C O M M U N I T Y S C H O O L D I S T R I C T WA U K E E , I O W A 1018B12A FEBRUARY 2024 35 0 1 1 0 4 t h S t r e e t , U r b a n d a l e , I A 5 0 3 2 2 P h : 5 1 5 - 2 7 6 - 0 4 6 7 BI S H O P E N G I N E E R I N G + L: \ L A N D P R O J E C T S 2 0 2 3 \ 2 3 0 1 1 5 - 2 W A U K E E H I G H S C H O O L A D D I T I O N U T I L I T Y R E L O C A T I O N \ D W G \ C 4 U T I L I T Y . D W G 2/ 1 4 / 2 0 2 4 8 : 1 0 : 0 4 A M GRAPHIC SCALE 020 10 20 40 C-402 UTILITY PLAN WATER MAIN PROFILE MIDAM TRANSFORMER NOTES: 1.4" CONDUIT TO BE TERMINATED INSIDE EXISTING MIDAM TRANSFORMER. 2.1, EMPTY 6" EXISTING CONDUIT EXISTS INSIDE TRANSFORMER. REMOVE EXISTING EMPTY 6" CONDUIT. 3.INSTALL NEW 4" CONDUIT INTO LOCATION OF FORMER 6" CONDUIT PER MIDAMERICAN STANDARDS.