Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2024-06-17 I01H_04 Public Safety Building_Change Order 3
AGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: June 17, 2024 AGENDA ITEM:Consideration of approval of Change Order No. 3 (Combined) for the Waukee Public Safety Building Project, increasing the contract in the amount of $21,816.91 FORMAT:Consent Agenda SYNOPSIS INCLUDING PRO & CON: Change Order No. 3 relates to the addition of millwork and counters within the police division of the building ($17,775.83), revisions to door hardware sets ($1,625.03) and additional streel plates associated with the curtain wall ($2,416.05). FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: The net result of this Change Order increases the contract price in the amount of $21,816.91. COMMISSION/BOARD/COMMITTEE COMMENT: STAFF REVIEW AND COMMENT: RECOMMENDATION: Approve the change order. ATTACHMENTS: I. Change Order No. 3 PREPARED BY:Brad Deets, City Administrator REVIEWED BY: PUBLIC NOTICE INFORMATION – NAME OF PUBLICATION: DATE OF PUBLICATION: I1H4 Ryan Companies 111 East Grand Avenue, Suite 200 Des Moines, Iowa 50309 ph: 515-309-8500 ryancompanies.com June 17, 2024 Brad Deets, City Administrator City of Waukee 230 W. Hickman Road Waukee, IA 50263 Re: Waukee Public Safety Building: Change Order No. 3: Multiple Pricing Request Approvals Dear Brad: Change Order No. 3 for the Waukee Public Safety Building includes the following revisions: · WPS CR019: PR-03: Added bent steel plates for curtainwall attachment. Value of $2,416.05 · WPS CR020: PR-05: Revisions to casework in rooms 302, 392, and 354. Added millwork, counters, and credited shelves. Value of $17,775.83. · WPS CR022: PR-07: Revision to door hardware sets. Value of $1,625.03. Ryan Companies recommends approval of the Prime Contractors for Change Order No. 3 at a combined value of $21,816.91. Please see attached Change Order No. 3 individual change orders and associated back up for each individual change request (CR) for additional information. If you have any questions or comments regarding this information, please contact me at your convenience. Thank you. Sincerely, RYAN COMPANIES US, INC. Jill Boetger Project Manager Enclosed: WPS Prime CO No. 3_DRAFT Ryan Companies 111 East Grand Avenue, Suite 200 Des Moines, Iowa 50309 ph: 515-309-8500 ryancompanies.com CC: Matt Van Loon, Ryan Companies Ryan Pigneri, Ryan Companies Angie Pfannkuch, Sidekick Development Danielle Hermann, OPN Architects Aaron Twedt, OPN Architects Alex Streyffeler, OPN Architects AIA ® Document G731™ – 2019 Change Order, Construction Manager as Adviser Edition AIA Document G731™ – 2019 (formerly G701™CMa – 1992). Copyright © 1992 and 2019 by The American Institute of Architects. All rights reserved. The “American Institute of Architects,” “AIA,” the AIA Logo, and “AIA Contract Documents” are registered trademarks and may not be used without permission. This draft was produced by AIA software at 12:27:48 ET on 09/23/2021 under Order No.2200100983 which expires on 03/01/2022, is not for resale, is licensed for one-time use only, and may only be used in accordance with the AIA Contract Documents® Terms of Service. To report copyright violations, e-mail copyright@aia.org. User Notes: (3B9ADA4A) 1 PROJECT: (name and address) CONTRACT INFORMATION: CHANGE ORDER INFORMATION: Waukee Public Safety Facility (WPS) Contract For: Bid Package #1 General Construction Change Order Number: WPS CO 03 (DDVI No. 2) 815 NW 20th Street Waukee, IA 50263 Date: 12.18.2023 Date: 06.17.2024 OWNER: (name and address) ARCHITECT: (name and address) CONSTRUCTION MANAGER: (name and address) City of Waukee OPN Architects Ryan Companies US, Inc. 230 W Hickman Road Waukee, IA 50263 100 Court Avenue, #100 Des Moines, IA 50309 111 East Grand Avenue, Des Moines, IA 50309 CONTRACTOR: (name and address) DDVI Inc PO Box 743 Indianola, IA 50125 THE CONTRACT IS CHANGED AS FOLLOWS: (Insert a detailed description of the change and, if applicable, attach or reference specific exhibits. Also include agreed upon adjustments attributable to executed Construction Change Directives.) Scope modifications will include: WPS CR020: PR-05: Revisions to casework in rooms 302, 392, and 354. Added millwork, counters, and credited shelves. Value of $17,216.30. WPS CR022: PR-07: Revisions to Door Hardware. Value of $1,573.88. The original Contract Sum was $ 2,905,000.00 Net change by previously authorized Change Orders $ 0.00 The Contract Sum prior to this Change Order was $ 2,905,000.00 The Contract Sum will be increased by this Change Order in the amount of $ 18,790.18 The new Contract Sum including this Change Order will be $ 2,923,790.18 The Contract Time will be increased by Zero (0) days. The Contractor’s Work shall be substantially complete on June 5, 2025. NOTE: This Change Order does not include adjustments to the Contract Sum or Guaranteed Maximum Price, or the Contract Time, that have been authorized by Construction Change Directive until the cost and time have been agreed upon by both the Owner and Contractor, in which case a Change Order is executed to supersede the Construction Change Directive. NOT VALID UNTIL SIGNED BY THE ARCHITECT, CONSTRUCTION MANAGER, CONTRACTOR, AND OWNER. OPN Architects Ryan Companies US, Inc. ARCHITECT (Firm name) CONSTRUCTION MANAGER (Firm name) SIGNATURE SIGNATURE Danielle Hermann, Principal Jill Boetger, Project Manager PRINTED NAME AND TITLE PRINTED NAME AND TITLE DATE: DATE: DDVI Inc. City of Waukee Iowa CONTRACTOR (Firm name) OWNER (Firm name) AIA Document G731™ – 2019 (formerly G701™CMa – 1992). Copyright © 1992 and 2019 by The American Institute of Architects. All rights reserved. The “American Institute of Architects,” “AIA,” the AIA Logo, and “AIA Contract Documents” are registered trademarks and may not be used without permission. This draft was produced by AIA software at 12:27:48 ET on 09/23/2021 under Order No.2200100983 which expires on 03/01/2022, is not for resale, is licensed for one-time use only, and may only be used in accordance with the AIA Contract Documents® Terms of Service. To report copyright violations, e-mail copyright@aia.org. User Notes: (3B9ADA4A) 2 SIGNATURE SIGNATURE PRINTED NAME AND TITLE PRINTED NAME AND TITLE Brad Deets, City Administrator DATE: DATE: AIA ® Document G731™ – 2019 Change Order, Construction Manager as Adviser Edition AIA Document G731™ – 2019 (formerly G701™CMa – 1992). Copyright © 1992 and 2019 by The American Institute of Architects. All rights reserved. The “American Institute of Architects,” “AIA,” the AIA Logo, and “AIA Contract Documents” are registered trademarks and may not be used without permission. This draft was produced by AIA software at 12:27:48 ET on 09/23/2021 under Order No.2200100983 which expires on 03/01/2022, is not for resale, is licensed for one-time use only, and may only be used in accordance with the AIA Contract Documents® Terms of Service. To report copyright violations, e-mail copyright@aia.org. User Notes: (3B9ADA4A) 1 PROJECT: (name and address) CONTRACT INFORMATION: CHANGE ORDER INFORMATION: Waukee Public Safety Facility (WPS) Contract For: Bid Package #4 Structural & Misc. Steel Material Change Order Number: WPS CO 03 (TSF No. 3) 815 NW 20th Street Waukee, IA 50263 Date: 12.18.2023 Date: 06.17.2024 OWNER: (name and address) ARCHITECT: (name and address) CONSTRUCTION MANAGER: (name and address) City of Waukee OPN Architects Ryan Companies US, Inc. 230 W Hickman Road Waukee, IA 50263 100 Court Avenue, #100 Des Moines, IA 50309 111 East Grand Avenue, Des Moines, IA 50309 CONTRACTOR: (name and address) TSF Structures, Inc. 6410 7th St Ct SW Cedar Rapids, IA 52404 THE CONTRACT IS CHANGED AS FOLLOWS: (Insert a detailed description of the change and, if applicable, attach or reference specific exhibits. Also include agreed upon adjustments attributable to executed Construction Change Directives.) Scope modifications will include: WPS CR019: PR-03: Added bent steel plates for curtainwall attachment. Value of $1,040.00 The original Contract Sum was $ 1,932,100.00 Net change by previously authorized Change Orders $ 1,130.00 The Contract Sum prior to this Change Order was $ 1,933,230.00 The Contract Sum will be increased by this Change Order in the amount of $ 1,040.00 The new Contract Sum including this Change Order will be $ 1,934,270.00 The Contract Time will be increased by Zero (0) days. The Contractor’s Work shall be substantially complete on June 5, 2025. NOTE: This Change Order does not include adjustments to the Contract Sum or Guaranteed Maximum Price, or the Contract Time, that have been authorized by Construction Change Directive until the cost and time have been agreed upon by both the Owner and Contractor, in which case a Change Order is executed to supersede the Construction Change Directive. NOT VALID UNTIL SIGNED BY THE ARCHITECT, CONSTRUCTION MANAGER, CONTRACTOR, AND OWNER. OPN Architects Ryan Companies US, Inc. ARCHITECT (Firm name) CONSTRUCTION MANAGER (Firm name) SIGNATURE SIGNATURE Danielle Hermann, Principal Jill Boetger, Senior Project Manager PRINTED NAME AND TITLE PRINTED NAME AND TITLE DATE: DATE: TSF Structures, Inc. City of Waukee Iowa CONTRACTOR (Firm name) OWNER (Firm name) AIA Document G731™ – 2019 (formerly G701™CMa – 1992). Copyright © 1992 and 2019 by The American Institute of Architects. All rights reserved. The “American Institute of Architects,” “AIA,” the AIA Logo, and “AIA Contract Documents” are registered trademarks and may not be used without permission. This draft was produced by AIA software at 12:27:48 ET on 09/23/2021 under Order No.2200100983 which expires on 03/01/2022, is not for resale, is licensed for one-time use only, and may only be used in accordance with the AIA Contract Documents® Terms of Service. To report copyright violations, e-mail copyright@aia.org. User Notes: (3B9ADA4A) 2 SIGNATURE SIGNATURE PRINTED NAME AND TITLE PRINTED NAME AND TITLE Brad Deets, City Administrator DATE: DATE: AIA ® Document G731™ – 2019 Change Order, Construction Manager as Adviser Edition AIA Document G731™ – 2019 (formerly G701™CMa – 1992). Copyright © 1992 and 2019 by The American Institute of Architects. All rights reserved. The “American Institute of Architects,” “AIA,” the AIA Logo, and “AIA Contract Documents” are registered trademarks and may not be used without permission. This draft was produced by AIA software at 12:27:48 ET on 09/23/2021 under Order No.2200100983 which expires on 03/01/2022, is not for resale, is licensed for one-time use only, and may only be used in accordance with the AIA Contract Documents® Terms of Service. To report copyright violations, e-mail copyright@aia.org. User Notes: (3B9ADA4A) 1 PROJECT: (name and address) CONTRACT INFORMATION: CHANGE ORDER INFORMATION: Waukee Public Safety Facility (WPS) Contract For: Bid Package #5 Precast & Steel Erection Change Order Number: WPS CO 03 (Northwest Steel No. 2) 815 NW 20th Street Waukee, IA 50263 Date: 12.18.2023 Date: 06.17.2024 OWNER: (name and address) ARCHITECT: (name and address) CONSTRUCTION MANAGER: (name and address) City of Waukee OPN Architects Ryan Companies US, Inc. 230 W Hickman Road Waukee, IA 50263 100 Court Avenue, #100 Des Moines, IA 50309 111 East Grand Avenue, Des Moines, IA 50309 CONTRACTOR: (name and address) Northwest Steel Erection, Inc. 6285 NE Industry Dr. Des Moines, IA 50313-7602 THE CONTRACT IS CHANGED AS FOLLOWS: (Insert a detailed description of the change and, if applicable, attach or reference specific exhibits. Also include agreed upon adjustments attributable to executed Construction Change Directives.) Scope modifications will include: WPS CR019: PR-03: Added bent steel plates for curtainwall attachment. Value of $660.00 The original Contract Sum was $ 1,064,188.00 Net change by previously authorized Change Orders $ 0.00 The Contract Sum prior to this Change Order was $ 1,064,188.00 The Contract Sum will be increased by this Change Order in the amount of $ 660.00 The new Contract Sum including this Change Order will be $ 1,064,848.00 The Contract Time will be increased by Zero (0) days. The Contractor’s Work shall be substantially complete on June 5, 2025. NOTE: This Change Order does not include adjustments to the Contract Sum or Guaranteed Maximum Price, or the Contract Time, that have been authorized by Construction Change Directive until the cost and time have been agreed upon by both the Owner and Contractor, in which case a Change Order is executed to supersede the Construction Change Directive. NOT VALID UNTIL SIGNED BY THE ARCHITECT, CONSTRUCTION MANAGER, CONTRACTOR, AND OWNER. OPN Architects Ryan Companies US, Inc. ARCHITECT (Firm name) CONSTRUCTION MANAGER (Firm name) SIGNATURE SIGNATURE Danielle Hermann, Principal Jill Boetger, Project Manager PRINTED NAME AND TITLE PRINTED NAME AND TITLE DATE: DATE: Northwest Steel Erection, Inc. City of Waukee Iowa CONTRACTOR (Firm name) OWNER (Firm name) AIA Document G731™ – 2019 (formerly G701™CMa – 1992). Copyright © 1992 and 2019 by The American Institute of Architects. All rights reserved. The “American Institute of Architects,” “AIA,” the AIA Logo, and “AIA Contract Documents” are registered trademarks and may not be used without permission. This draft was produced by AIA software at 12:27:48 ET on 09/23/2021 under Order No.2200100983 which expires on 03/01/2022, is not for resale, is licensed for one-time use only, and may only be used in accordance with the AIA Contract Documents® Terms of Service. To report copyright violations, e-mail copyright@aia.org. User Notes: (3B9ADA4A) 2 SIGNATURE SIGNATURE PRINTED NAME AND TITLE PRINTED NAME AND TITLE Brad Deets, City Administrator DATE: DATE: AIA ® Document G731™ – 2019 Change Order, Construction Manager as Adviser Edition AIA Document G731™ – 2019 (formerly G701™CMa – 1992). Copyright © 1992 and 2019 by The American Institute of Architects. All rights reserved. The “American Institute of Architects,” “AIA,” the AIA Logo, and “AIA Contract Documents” are registered trademarks and may not be used without permission. This draft was produced by AIA software at 12:27:48 ET on 09/23/2021 under Order No.2200100983 which expires on 03/01/2022, is not for resale, is licensed for one-time use only, and may only be used in accordance with the AIA Contract Documents® Terms of Service. To report copyright violations, e-mail copyright@aia.org. User Notes: (3B9ADA4A) 1 PROJECT: (name and address) CONTRACT INFORMATION: CHANGE ORDER INFORMATION: Waukee Public Safety Facility (WPS) Contract For: Bid Package #7 Roofing Change Order Number: WPS CO 03 (Academy No. 3) 815 NW 20th Street Waukee, IA 50263 Date: 12.18.2023 Date: 06.17.2024 OWNER: (name and address) ARCHITECT: (name and address) CONSTRUCTION MANAGER: (name and address) City of Waukee OPN Architects Ryan Companies US, Inc. 230 W Hickman Road Waukee, IA 50263 100 Court Avenue, #100 Des Moines, IA 50309 111 East Grand Avenue, Des Moines, IA 50309 CONTRACTOR: (name and address) Academy Roofing & Sheet Metal Co. 6361 NE 14th Street Des Moines, IA 50313 THE CONTRACT IS CHANGED AS FOLLOWS: (Insert a detailed description of the change and, if applicable, attach or reference specific exhibits. Also include agreed upon adjustments attributable to executed Construction Change Directives.) Scope modifications will include: WPS CR019: PR-03: Added bent steel plates for curtainwall attachment. Value of $640.00 The original Contract Sum was $ 998,000.00 Net change by previously authorized Change Orders $ 780.00 The Contract Sum prior to this Change Order was $ 998,780.00 The Contract Sum will be increased by this Change Order in the amount of $ 640.00 The new Contract Sum including this Change Order will be $ 999,420.00 The Contract Time will be increased by Zero (0) days. The Contractor’s Work shall be substantially complete on June 5, 2025. NOTE: This Change Order does not include adjustments to the Contract Sum or Guaranteed Maximum Price, or the Contract Time, that have been authorized by Construction Change Directive until the cost and time have been agreed upon by both the Owner and Contractor, in which case a Change Order is executed to supersede the Construction Change Directive. NOT VALID UNTIL SIGNED BY THE ARCHITECT, CONSTRUCTION MANAGER, CONTRACTOR, AND OWNER. OPN Architects Ryan Companies US, Inc. ARCHITECT (Firm name) CONSTRUCTION MANAGER (Firm name) SIGNATURE SIGNATURE Danielle Hermann, Principal Jill Boetger, Senior Project Manager PRINTED NAME AND TITLE PRINTED NAME AND TITLE DATE: DATE: Academy Roofing & Sheet Metal Co. City of Waukee Iowa CONTRACTOR (Firm name) OWNER (Firm name) AIA Document G731™ – 2019 (formerly G701™CMa – 1992). Copyright © 1992 and 2019 by The American Institute of Architects. All rights reserved. The “American Institute of Architects,” “AIA,” the AIA Logo, and “AIA Contract Documents” are registered trademarks and may not be used without permission. This draft was produced by AIA software at 12:27:48 ET on 09/23/2021 under Order No.2200100983 which expires on 03/01/2022, is not for resale, is licensed for one-time use only, and may only be used in accordance with the AIA Contract Documents® Terms of Service. To report copyright violations, e-mail copyright@aia.org. User Notes: (3B9ADA4A) 2 SIGNATURE SIGNATURE PRINTED NAME AND TITLE PRINTED NAME AND TITLE Brad Deets, City Administrator DATE: DATE: w PROPOSAL REQUEST – PR NO. 03 Please submit an itemized proposal for changes in the Contract Sum and Contract Time for proposed modifications to the Contract Documents described herein. This is not a Change Order, a Construction Change Directive or a direction to proceed with the w ork described in the proposed modifications. Proceeding with the Work prior to authorization indicates your acknowledgement that there will be no change in the Contract Sum or Contract Time. Description: xxx 1. Sheet S311 - HIGH ROOF FRAMING PLAN • A/S311: ADD detail callout at north curtainwall opening on high roof framing plan. Detail is typical of (3) openings on north elevation. • 1/S311: ADD new detail showing bent plate and precast embed for curtain wall head condition. 2. Sheet A232 – EXTERIOR GLAZING DETAILS • M21/A23: Update steel plate to match new structure detail. Update insulation and blocking to work with new plate dimensions. Add flexible flashing and sheet metal flashing at curtainwall head as shown. OPN Architects, Inc. Date: 04/19/2024 Project: Waukee Public Safety Facility Project number: 21841001 Client: City of Waukee Construction Manager: Ryan Companies BACKER ROD & SEALANT (BOTH SIDES) INSULATED PRECAST CONCRETE WALL PANEL - SEE ELEVATIONS 4" 4" 4" 1" INSULATED GLASS 1/ 2 " 2 1 / 2 " FLEXIBLE FLASHING 1'-0" ALUMINUM CURTAIN WALL SYSTEM INTERIOR EXTERIOR TREATED WOOD NAILER 6" LEVEL 1 0" A F.O. GLASS 8" 7" 1" 4" 6" 2" 4" 1'-0" EXTERIORINTERIOR 1" INSULATED GLASS ALUMINUM CURTAIN WALL SYSTEM BACKER ROD & SEALANT (BOTH SIDES) CONCRETE STOOP -SEE STRUCT, SLOPE FOR POSITIVE DRAINAGE 2" RIGID PERIMETER INSULATION 4" VOID FORM MATERIAL CONCRETE FOOTING -SEE STRUCTURAL CONCRETE STEM WALL WITH RIGID INSULATION AND THERMOMASS CLIPS -SEE STRUCTURAL COMPACTED GRANULAR FILL -SEE STRUCTURAL CONTINUOUS VAPOR BARRIER CONCRETE SLAB ON GRADE -SEE STRUCTURAL TREATED WOOD NAILER A 3" 6" 1" INSULATED GLASS ALUMINUM CURTAIN WALL SYSTEM 2 1 / 2 " F.O. GLASS 8" STANDARD MULLION CAP A UPPER PRECAST 27'-0" F.O. GLASS 8" 4" ALUMINUM CURTAIN WALL HEAD 1" INSULATED GLASS BLOCKING 5/8" F.R. TREATED PLYWOOD 1 1/2" RIGID INSULATION STEEL PLATE -SEE STRUCTURE PREFINISHED METAL COPING 1" RIGID INSULATION 3" 1 1 / 2 " 1 1 / 2 " 1'-0" PR 03 FLEXIBLE FLASHING SHEET METAL FLASHING 3 F.O. GLASS 1'-1" 1" INSULATED GLASS 2 1 / 2 " SSG MULLION JOINT LIGHTING AND DEVICES - SEE ELECTRICAL 4"CONTINUOUS (COLUMN TO COLUMN) 18 GA. BRAKE METAL MOUNTING PLATE TO CONCEAL FIXTURES, DIRECT ATTACH TO STEEL BEAM BELOW, SPLICE AT MULLION JOINTS, PAINT TO MATCH STEEL BEAM/COLUMNS ALUMINUM CURTAIN WALL SYSTEM 10'-0" STEEL TUBE -SEE STRUCTURAL 6" STEEL CHANNEL - SEE STRUCTURAL 10 1" INSULATED GLASS ALUMINUM CURTAIN WALL SYSTEM WIRE HANGERS AT INTERMEDIATE MEMBERS AS REQUIRED SUSPENSION RAIL INSULATED ALUMINUM BACKPAN STEEL TUBE -SEE STRUCTURAL STANDARD MULLION CAP LINEAR WOOD SOFFIT -SEE RCP FOR TYPE INSULATED PRECAST CONCRETE WALL PANEL BEYOND 6"9" 1'-2" F.O.G. PERFORATED METAL CLOSURE ANGLE - PAINT BLACK 24'-4" FLEXIBLE FLASHING E STEEL TUBE -SEE STRUCTURAL 1" INSULATED GLASS ALUMINUM CURTAIN WALL SYSTEM LINEAR WOOD SOFFIT -SEE RCP FOR TYPE WIRE HANGERS AT INTERMEDIATE MEMBERS AS REQUIRED SEE RCP FOR CEILING TYPES SUSPENSION RAIL STANDARD MULLION CAP 6" 9" F.O. GLASS 1'-2" PERFORATED METAL CLOSURE ANGLE - PAINT BLACK INSULATED ALUMINUM BACKPAN 4" FLEXIBLE FLASHING 24'-4" PREFINISHED BRAKE METAL CLOSURE ANGLE -BLACK, ALL FASTENERS TO MATCH MM.1 1" INSULATED GLASS ALUMINUM CURTAIN WALL SYSTEM SUSPENSION RAIL WIRE HANGERS AT INTERMEDIATE MEMBERS AS REQUIRED F.O.G. 2" 1'-0" STEEL TUBE -SEE STRUCTURAL ROLLER SHADE -SEE RCP INSULATED ALUMINUM BACKPAN 4" SEE RCP FOR CEILING TYPES STANDARD MULLION CAP LINEAR WOOD SOFFIT -SEE RCP FOR TYPE PERFORATED METAL CLOSURE ANGLE - PAINT BLACK FLEXIBLE FLASHING 6" METAL STUD FRAMING 6" 9" UPPER PRECAST 27'-0" 89 LINEAR WOOD SOFFIT -SEE RCP FOR TYPE SUSPENSION RAIL ALUMINUM CURTAIN WALL SYSTEM 1" INSULATED GLASS ROOF MEMBRANE 1/2" COVER BOARD RIGID (FOAM BOARD) STEEL ROOF DECK -SEE STRUCTURAL A232 G2 FLUID-APPLIED THERMAL BREAK STEEL PLATE CURTAIN WALL ANCHOR 24'-4" FLEXIBLE FLASHING LINEAR SLOT DIFFUSER, SEE MECHANICAL 8" 9 24'-4" 6" 3" F.O. GLASS 8" SEE RCP FOR CEILING TYPES LINEAR WOOD SOFFIT -SEE RCP FOR TYPE SUSPENSION RAIL 1" INSULATED GLASS ALUMINUM CURTAIN WALL SYSTEM STANDARD MULLION CAP BRAKE METAL CLOSURE 3/8" INSULATED ALUMINUM BACKPAN FLEXIBLE FLASHING INSULATED PRECAST CONCRETE WALL PANEL -SEE ELEVATIONS SUSPENSION RAIL LINEAR WOOD SOFFIT -SEE RCP FOR TYPE CONTINUOUS SEALANT TREATED WOOD NAILER LEVEL 1 0" 3 F.O. GLASS 1'-1" EXTERIOR INTERIOR 1"4" 6"2"4" 1'-0" CONCRETE SLAB ON GRADE -SEE STRUCTURAL IN-FLOOR UNIT HEATER WHERE INDICATED - SEE MECHANICAL CONCRETE STEM WALL WITH RIGID INSULATION AND THERMOMASS CLIPS -SEE STRUCTURAL COMPACTED GRANULAR FILL -SEE STRUCTURAL CONTINUOUS VAPOR BARRIER CONCRETE FOOTING -SEE STRUCTURAL 1" INSULATED GLASS ALUMINUM CURTAIN WALL SYSTEM BACKER ROD & SEALANT (BOTH SIDES) TREATED WOOD NAILER CONCRETE STOOP -SEE STRUCT, SLOPE FOR POSITIVE DRAINAGE 2" RIGID PERIMETER INSULATION 4" VOID FORM MATERIAL 5 1 / 2 " 4 " STEEL COLUMN - SEE STRUCTRUAL (BEYOND) CONTINUOUS SEALANT AROUND PERIMETER OF UNIT HEATER RECESSED CONCRETE BLOCKOUT FOR UNIT HEATER ADJUSTMENT FEET 1'-1" PROVIDE MINIMUM CONCRETE AT ALL SIDES OF UNIT 4" 2" 6" A 19181716151413121110987654 B C D E F G H J K L M N P Q PR I N T E D : R S T U 20 21 22 23 24 25 Sheet Name Key Plan 321 19181716151413121110987654 20 21 22 23 24 25321 Sheet Number Sheet Issue Date OPN Project No. 26 26 27 27 28 28 29 29 V W X Y Owner All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc. shall retain all common law, statutory and other reserved rights, including the copyright thereto. © 2022 OPN Architects, Inc. 100 Court Ave., Suite 100 Des Moines, IA 50309 P: 515-309-0722 www.opnarchitects.com RYAN COMPANIES 111 E GRAND AVENUE, SUITE 200 DES MOINES, IA 50309 P. 515-309-8500 Project Construction Manager FOTH 8191 BIRCHWOOD COURT, SUITE L JOHNSTON, IA 50131 P. 515-254-1393 Civil Engineer RAKER RHODES ENGINEERING 4717 GRAND AVENUE DES MOINES, IA 50313 P. 515-277-0275 Structural Engineer MORRISSEY ENGINEERING 4940 NORTH 118TH STREET OMAHA, NE 68164 P. 402-491-4144 MEPT Engineer CONFLUENCE 525 17TH STREET DES MOINES, IA 50309 P. 515-288-4875 Landscape Architect A B C 4/ 2 3 / 2 0 2 4 9 : 3 5 : 1 4 A M A232 EXTERIOR GLAZING DETAILS 21841001 CONSTRUCTION SET 11/21/2023 WAUKEE PUBLIC SAFETY BUILDING 815 NW 20th STREET WAUKEE, IA 50263 CITY OF WAUKEE 230 W. HICKMAN ROAD WAUKEE, IA 50263 3" = 1'-0"T21 EXTERIOR SECTION DETAIL - CURTAIN WALL HEAD AT PRECAST 3" = 1'-0"A21 EXTERIOR SECTION DETAIL - TYP. CURTAIN WALL SILL 3" = 1'-0"G21 EXTERIOR SECTION DETAIL - TYP. STANDARD MULLION (M-1) 3" = 1'-0"M21 EXTERIOR SECTION DETAIL - CURTAIN WALL HEAD AT PARAPET 3" = 1'-0"G11 EXTERIOR SECTION DETAIL - TYP. SSG MULLION (M-2) 3" = 1'-0"M11 EXTERIOR SECTION DETAIL - APPARATUS BAY CW AT CANOPY HEAD 3" = 1'-0"M2 EXTERIOR SECTION DETAIL - CURTAIN WALL AT CANOPY HEAD 3" = 1'-0"T2 EXTERIOR SECTION DETAIL - CURTAIN WALL AT CANOPY HEAD SHADING 1 1/2" = 1'-0"T11 EXTERIOR SECTION DETAIL - FITNESS CURTAIN WALL HEAD 3" = 1'-0"G2 EXTERIOR SECTION DETAIL - STANDARD MULLION CURTAIN W ALL HEAD AT CANOPY 3" = 1'-0"A2 EXTERIOR SECTION DETAIL - CANOPY TO PRECAST Revision Description Date PR 03 PR 4/19/2024 3" = 1'-0"A11 EXTERIOR SECTION DETAIL - LOBBY CURTAIN WALL SILL 2 11 A B C D 7.4 4' - 0"4' - 0"5' - 0"5' - 0"5' - 0"5' - 9"6' - 0"5' - 9"5' - 8"6' - 0"6' - 0"6' - 0"6' - 0"6' - 0"6' - 0"6' - 0"6' - 0"6' - 0"5' - 0"2' - 10" 4 10 B.1 B.2 B.3 D -1 18 ' - 6 " 18 ' - 8 " 17 ' - 4 " 17 ' - 4 " 18 ' - 8 " 18 ' - 0 " 10 8 ' - 6 " 108' - 0" 7' - 0"15' - 8"26' - 0"13' - 4"26' - 10"12' - 2"7' - 0" D - 4 6' - 11 1/2"5' - 6"5' - 6"5' - 6"6' - 6"6' - 6"6' - 6"6' - 6"6' - 8"6' - 8"6' - 8"6' - 9"6' - 9"6' - 8"6' - 6"6' - 6"6' - 11 1/2" 9 S401 ------------------------------------------------------------------------------------------------------------------- 6' - 1 1 1 / 2 " 5' - 7 " 5' - 8 " 5' - 7 " 1' - 8 " 4' - 4 " 5' - 8 " 5' - 8 " 3' - 0 " 3' - 0 " 5' - 8 " 5' - 8 " 3' - 0 " 3' - 0 " 5' - 8 " 5' - 8 " 3' - 0 " 3' - 0 " 5' - 8 " 5' - 8 " 4' - 4 " D - 1 D - 1 4' - 4 " 5' - 8 " 5' - 8 " 3' - 0 " 3' - 0 " 5' - 8 " 5' - 8 " 5' - 8 " 5' - 8 " 3' - 0 " 3' - 0 " 5' - 8 " 5' - 8 " 3' - 0 " 3' - 0 " 6' - 1 1 1 / 2 " 5' - 7 " 5' - 8 " 5' - 7 " 1' - 8 " 4' - 4 " D -1 D - 4 D - 4 D - 4 D -1 12 K 1 12 K 1 12 K 1 12 K 1 12 K 1 12 K 1 12 K 1 12 K 1 12 K 1 12 K 1 12 K 1 12 K 1 12 K 1 12 K 1 12 K 1 12 K 1 12 K 1 HSS18X6X3/8 + HSS6X6X1/4 HSS18X6X3/8 + HSS6X6X1/4 HSS18X6X3/8 + HSS6X6X1/4 HSS18X6X3/8 + HSS6X6X1/4 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35W18X35W18X35W18X35 W1 8 X 3 5 W1 8 X 3 5 W1 8 X 3 5 W1 8 X 3 5 W1 8 X 3 5 W 1 8 X 3 5 W18X35 W18X35 W18X35 7 S401 TYP. ------------------------------------------------------------------------------------------------------------------- HS S 1 8 X 6 X 3 / 8 + HS S 6 X 6 X 1 / 4 W1 8 X 3 5 W18X35 W1 8 X 3 5 W1 8 X 3 5 W1 8 X 3 5 W1 8 X 3 5 W 1 8 X 3 5 W18X35 W18X35 W18X35 W18X35 W18X35 W1 8 X 3 5 W18X35 HS S 1 8 X 6 X 3 / 8 + HS S 6 X 6 X 1 / 4 W18X35 W18X35 W18X35 5 75.1 W 1 8 X 3 5 W1 8 X 3 5 W 1 8 X 3 5 HS S 2 0 X 8 X 3 / 8 + HS S 8 X 8 X 3 / 8 HS S 2 0 X 8 X 3 / 8 + HS S 8 X 6 X 3 / 8 ( L S H ) HS S 2 0 X 8 X 3 / 8 + HS S 8 X 6 X 3 / 8 ( L S H ) HS S 2 0 X 8 X 3 / 8 + HS S 8 X 8 X 3 / 8 HS S 2 0 X 8 X 3 / 8 + HS S 8 X 8 X 3 / 8 HS S 2 0 X 8 X 3 / 8 + HS S 8 X 6 X 3 / 8 ( L S H ) HS S 2 0 X 8 X 3 / 8 + HS S 8 X 6 X 3 / 8 ( L S H ) HS S 2 0 X 8 X 3 / 8 + HS S 8 X 8 X 3 / 8 L4 X 3 X 1 / 4 6 S402 TYP. ------------------------------------------------------------------------------------------------------------------- 6 S402 TYP. ------------------------------------------------------------------------------------------------------------------- 10 S402 TYP. ------------------------------------------------------------------------------------------------------------------- 10 S402 TYP. ------------------------------------------------------------------------------------------------------------------- 2 S403 TYP. ------------------------------------------------------------------------------------------------------------------- 1 S403 ------------------------------------------------------------------------------------------------------------------- 3 S403 TYP. ------------------------------------------------------------------------------------------------------------------- 1 S403 ------------------------------------------------------------------------------------------------------------------- OPP. 27' - 0" TYP. HSS18X6X3/8 + HSS6X6X1/4 27' - 0" TYP.8 S403 TYP. ------------------------------------------------------------------------------------------------------------------- 12 K 1 [ 25 ' - 1 5 / 8 " ] W 1 2 X 1 9 [ 26 ' - 6 1 / 8 " ] [ 25 ' - 1 5 / 8 " ] W 1 2 X 1 9 [ 26 ' - 6 1 / 8 " ] [ 25 ' - 1 5 / 8 " ] W 1 2 X 1 9 [ 26 ' - 6 1 / 8 " ] [ 25 ' - 1 5 / 8 " ] W 1 2 X 1 9 [ 26 ' - 6 1 / 8 " ] [ 25 ' - 1 5 / 8 " ] W 1 2 X 1 9 [ 26 ' - 6 1 / 8 " ] [ 25 ' - 1 5 / 8 " ] W 1 2 X 1 9 [ 26 ' - 6 1 / 8 " ] [ 25 ' - 1 5 / 8 " ] W 1 2 X 1 9 [ 26 ' - 6 1 / 8 " ] [ 25 ' - 1 5 / 8 " ] W 1 2 X 1 9 [ 26 ' - 6 1 / 8 " ] [ 25 ' - 1 5 / 8 " ] W 1 2 X 1 9 [ 26 ' - 6 1 / 8 " ] [ 25 ' - 1 5 / 8 " ] W 1 2 X 1 9 [ 26 ' - 6 1 / 8 " ] [ 25 ' - 1 5 / 8 " ] W 1 2 X 1 9 [ 26 ' - 6 1 / 8 " ] [ 25 ' - 1 5 / 8 " ] W 1 2 X 1 9 [ 26 ' - 6 1 / 8 " ] [ 25 ' - 1 5 / 8 " ] W 1 2 X 1 9 [ 26 ' - 6 1 / 8 " ] [ 25 ' - 1 5 / 8 " ] W 1 2 X 1 9 [ 26 ' - 6 1 / 8 " ] W - 2 KIPS E - 3 KIPS W - 12 KIPS E - 6 KIPS W - 1 1 K I P S E - 8 K I P S W - 1 1 K I P S E - 8 K I P S 9 S401 ------------------------------------------------------------------------------------------------------------------- W - 13 KIPS E - 8 KIPS ROOF TRUSS - T2 ROOF TRUSS - T2 27' - 0" 27 ' - 0 " 27' - 0" 24' - 11" 24 ' - 7 " 25 ' - 1 1 / 2 " 12 S404 TYP. ------------------------------------------------------------------------------------------------------------------- 12 S404 TYP. ------------------------------------------------------------------------------------------------------------------- 4 S405 TYP. ------------------------------------------------------------------------------------------------------------------- TYP. 1' - 6 " 1' - 6 " 10" 6' - 11 1/2" 24' - 7" TYP. 2 5 ' - 4 "TYP./1 S404SEE DETAIL /1 S404SEE DETAIL /1 S404SEE DETAIL ROOF TRUSS - T1 __________________________________ S401 6 TYP. __________________________________ S405 106' - 11 1/2" 10" 12 S405 ------------------------------------------------------------------------------------------------------------------- 12 S405 ------------------------------------------------------------------------------------------------------------------- OPP. 27 ' - 0 " 27 ' - 0 " 03 ASI 03 ASI T/STEEL = [24'-10 1/2"] T/STEEL = [25'-2"] T/STEEL = [24'-10 1/2"] 03 ASI 03 ASI 03 ASI 03 PR 1 S311 TYP. ------------------------------------------------------------------------------------------------------------------- DECKING SCHEDULE 1 1/2" -20 GA. TYPE B ROOF DECK SEE S0.1, NOTE SD4D -1 -- MARK TYPE DETAILS NOTES 1 1/2" -20 GA. TYPE B ACOUSTIC ROOF DECK --D -1A 3" -20 GA. TYPE N ACOUSTIC ROOF DECK AT MECHANICAL MEZZ. & AT CMU ENCLOSURE D -2A EPICORE ENVISTA FN7.9A 18 GA. ACOUSTIC CELLULAR ROOF DECK CUSTOM FACTORY FINISH, SEE ARCH D -4 SEE S0.1, NOTE SD4 SEE S0.1, NOTE SD4 SEE S0.1, NOTE SD4 SEE S0.1, NOTE SD4 2" -18 GA. COMPOSITE FLOOR DECK + 4-1/2" N.W. CONCRETE TOPPING (6-1/2" TOTAL THICKNESS) w/ WWF6x6-W2.1xW2.1 D -3 --- AT APPARATUS BAY ROOF --3" -20 GA. TYPE N ROOF DECKD -2 SEE S0.1, NOTE SD4 1.0C x 24 GA. FORMDECKD -5 SEE S0.1, NOTE SD4 AT LOBBY VESTIBULE TYPICAL FRAMING DESIGNATION STEEL COLUMN STEEL BEAM MOMENT CONNECTION CONNECTION SYMBOLS BEAM OVER COLUMN OWJ OR BEAM SIZE TOP OF STEEL OR TOP OF JOIST ELEVATION END REACTION (SERVICE) # OF HEADED STUDS REQ'D CAMBER [ 18' -6" ] W18X35 (20) C = 3/4"5k 5kW" x H" WEB OPENING SEE 2/S404 F J 1 12 7' - 8 1 / 2 " 3' - 8 " 6' - 0 " 4' - 0 " 10 ' - 0 " 8' - 6 " 1' - 6 " 13 ' - 4 " 1' - 6 " 8' - 6 " 10 ' - 0 " 4' - 0 " 6' - 0 " 3' - 8 " 83 E.1 F.1 H K.2 L.2 D - 2 M 119' - 0" 10' - 8"19' - 2"39' - 4"35' - 4"14' - 6" 4' - 10"4' - 10"4' - 10"6' - 11 1/2"5' - 4"5' - 4" L D - 2 D - 2 D - 2 D - 1 D - 2 D - 1 D -1 D -1 5 S401 TYP. ------------------------------------------------------------------------------------------------------------------- E 80 ' - 8 " G K E.2 L.1 6' - 11 1/2" 7' - 8 1 / 2 " 5' - 10" 3' - 2 1/4"2' - 7 3/4" 5' - 11"5' - 11"5' - 11"5' - 11" 5 7 5' - 7"5' - 7"5' - 7"5' - 7"5' - 8"5' - 8"5' - 8"6' - 4 1/2"6' - 5"6' - 4 1/2" 3' - 6 " 5' - 0 " 5' - 0 " 5' - 0 " 5' - 0 " 5' - 0 " 5' - 0 " 3' - 6 " 1' - 0 " 6' - 8 " 6' - 8 " 1' - 0 " 1' - 1 0 " 3' - 2 " 7.3 1 S402 ------------------------------------------------------------------------------------------------------------------- BR A C E D F R A M E 7 S402 TYP. ------------------------------------------------------------------------------------------------------------------- 7 S402 TYP. ------------------------------------------------------------------------------------------------------------------- 8 S402 TYP. ------------------------------------------------------------------------------------------------------------------- 8 S402 TYP. ------------------------------------------------------------------------------------------------------------------- 1 S402 ------------------------------------------------------------------------------------------------------------------- BR A C E D F R A M E W1 4 X 2 2 [ 26 ' - 0 " ] W1 4 X 2 2 [ 26 ' - 0 " ] W 1 4 X 2 2 [ 26 ' - 0 " ] W1 6 X 4 5 [ 26 ' - 0 " ] W12X19 [ 26' - 0" ] W12X19 [ 26' - 0" ] W12X19 [ 26' - 0" ] W12X19 [ 26' - 0" ] W12X19 [ 26' - 0" ] W12X19 [ 26' - 0" ] W12X19 [ 26' - 0" ] W16X45 [ 26' - 0" ] W16X45 [ 26' - 0" ] W16X45 [ 26' - 0" ] W16X45 [ 26' - 0" ] W16X45 [ 26' - 0" ] W16X45 [ 26' - 0" ] W16X45 [ 26' - 0" ] W16X31 [ 26' - 0" ] W16X31 [ 26' - 0" ] W16X31 [ 26' - 0" ] W16X31 [ 26' - 0" ] W16X31 [ 26' - 0" ] W16X31 [ 26' - 0" ] W16X31 [ 26' - 0" ] DBL HSS12X6X3/8 DBL HSS12X6X3/8 [ 26' - 0" ] W12X19 DBL HSS12X6X3/8 DBL HSS12X6X3/8 DBL HSS12X6X3/8 W12X19 [ 26' - 0" ] W16X45 [ 26' - 0" ] W16X31 [ 26' - 0" ] W12X19 [ 26' - 0" ] W16X45 [ 26' - 0" ] W16X31 [ 26' - 0" ] DBL HSS12X6X3/8 W18X35 W1 4 X 2 2 [ 26 ' - 0 " ] W 1 4 X 2 2 [ 26 ' - 0 " ] W1 6 X 4 5 [ 26 ' - 0 " ] W 1 6 X 4 5 [ 26 ' - 0 " ] W18X35 W18X35 W18X35W18X35W18X35 W 1 8 X 3 5W18X35W18X35W18X35W 1 8 X 3 5 W1 8 X 3 5W18X35W 1 8 X 3 5 [ 26' - 0" ] W12X19 [ 26' - 0" ] W12X19 [ 26' - 0" ] W12X19 [ 26' - 0" ] W12X19 [ 26' - 0" ] W12X19 [ 26' - 0" ] W12X19 [ 26' - 0" ] W12X19 [ 26' - 0" ] W12X19 [ 26' - 0" ] W12X19 [ 26' - 0" ] W12X19 [ 26' - 0" ] W12X19 [ 26' - 0" ] W12X19 [ 26' - 0" ] W12X19 [ 26' - 0" ] W12X19 [ 26' - 0" ] W12X19 [ 26' - 0" ] W12X19 [ 26' - 0" ] W12X19 W 2 1 X 4 4 [ 26 ' - 0 " ] W2 1 X 4 4 [ 26 ' - 0 " ] W 2 1 X 4 4 [ 26 ' - 0 " ] W 2 1 X 4 4 [ 26 ' - 0 " ] W 2 1 X 4 4 [ 26 ' - 0 " ] W 1 6 X 2 6 [ 26 ' - 0 " ] W1 6 X 2 6 [ 26 ' - 0 " ] W1 6 X 2 6 [ 26 ' - 0 " ] W 1 6 X 4 5 [ 26 ' - 0 " ] W18X35 W18X35 W1 8 X 3 5 W18X35 W 1 8 X 3 5 W 1 8 X 3 5 W 1 8 X 3 5 W 1 8 X 3 5 W 1 8 X 3 5 W 1 8 X 3 5 W 1 8 X 3 5 W 1 8 X 3 5 W 1 8 X 3 5 W 1 8 X 3 5 W 1 8 X 3 5 W 1 8 X 3 5 W 1 8 X 3 5 W 1 8 X 3 5 W 1 8 X 3 5 W 1 8 X 3 5 W 1 8 X 3 5 W 1 8 X 3 5 W 1 8 X 3 5 W 1 8 X 3 5 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W18X35 W1 8 X 3 5 W1 8 X 3 5 W1 8 X 3 5 W1 8 X 3 5 W1 8 X 3 5 W1 8 X 3 5 W1 8 X 3 5 W1 8 X 3 5 W1 8 X 3 5 W1 8 X 3 5 W1 8 X 3 5 W1 8 X 3 5 W1 8 X 3 5 W1 8 X 3 5 W1 8 X 3 5 W1 8 X 3 5 W1 8 X 3 5 W1 8 X 3 5 W1 8 X 3 5 [ 26 ' - 0 " ] W 1 6 X 2 6 W1 6 X 2 6 [ 26 ' - 0 " ] 27' - 0" TYP. 27' - 0" TYP. 6 S403 TYP. -------------------------------------------------------------------------------------------------------------------TYP. 6 S403 TYP. ------------------------------------------------------------------------------------------------------------------- 27' - 0" TYP. 18 S403 TYP. ------------------------------------------------------------------------------------------------------------------- 27' - 0" HS S 2 4 X 1 2 X 1 / 2 HS S 2 4 X 1 2 X 1 / 2 HS S 2 4 X 1 2 X 1 / 2 HS S 2 4 X 1 2 X 1 / 2 HS S 2 4 X 1 2 X 1 / 2 HS S 2 4 X 1 2 X 1 / 2 HS S 2 4 X 1 2 X 1 / 2 HS S 2 4 X 1 2 X 1 / 2 HS S 2 4 X 1 2 X 1 / 2 HS S 2 4 X 1 2 X 1 / 2 HS S 2 4 X 1 2 X 1 / 2 HS S 2 4 X 1 2 X 1 / 2 HS S 2 4 X 1 2 X 1 / 2 HS S 2 4 X 1 2 X 1 / 2 [ 26 ' - 0 " ] W1 6 X 4 5 W8 X 1 3 W8 X 1 3 16 " x 1 2 " EQ . EQ . 3' - 0 " 2' - 8 " 16 " x 1 2 " EQ . EQ . 24 " x 1 1 " 20 " x 1 2 " EQ . EQ . 3' - 2 " 2' - 1 0 " 20 " x 1 2 " 2' - 6 " EQ . EQ . EQ . 3' - 0 " 1' - 1 0 " 16 " x 1 2 " 16 " x 1 2 " 20 " x 1 2 " 24 " x 1 1 " 20 " x 1 2 " 16 " x 1 2 " 16 " x 1 2 " EQ . EQ . 1' - 9 " 2' - 2 " EQ . EQ . EQ . EQ . EQ . EQ . EQ . 1' - 9 " 1' - 1 0 " 3' - 0 " EQ . EQ . EQ . 2' - 6 " 2" Ø 2" Ø 1" Ø 1" Ø 1 S405 ------------------------------------------------------------------------------------------------------------------- 2" Ø 1" Ø 2" Ø 1" Ø 2" x 4 " 2" x 4 " 2" Ø 1" Ø 2" x 4 " 2" x 4 " 2" x 4 " __________________________________ S405 9 TYP. __________________________________ S401 6 TYP.2 S405 TYP. ------------------------------------------------------------------------------------------------------------------- 2 S405 TYP. ------------------------------------------------------------------------------------------------------------------- 2' - 0 " 2' - 0 " 2' - 0 " 2' - 0 " 13 S405 ------------------------------------------------------------------------------------------------------------------- 13 S405 ------------------------------------------------------------------------------------------------------------------- 13 S405 ------------------------------------------------------------------------------------------------------------------- 13 S405 ------------------------------------------------------------------------------------------------------------------- 14 S405 TYP. ------------------------------------------------------------------------------------------------------------------- 14 S405 TYP. ------------------------------------------------------------------------------------------------------------------- 03 ASI A NOTE: SEE ARCH FOR NON-STRUCTURAL COMPONENTS. PRECAST FRAMING BY CONTRACTOR (BEYOND), SEE PLAN CURTAIN WALL, SEE ARCH EMBED BY PRECAST SUPPLIER, TYP. @ EACH SIDE OF CURTAIN WALL OPENING JOIST BEARING SEE PLAN 1/4 1/4 EA. EMBED L4x4x1/4 CONT. DECK EDGE ANGLE ROOF DECK, SEE PLAN 3/8" BENT PLATE (GALVANIZED) LH SERIES JOIST (BEYOND), SEE PLAN JOIST SEAT ANGLE (BEYOND) A 19181716151413121110987654 B C D E F G H J K L M N P Q PR I N T E D : R S T U 20 21 22 23 24 25 Sheet Name Key Plan 321 19181716151413121110987654 20 21 22 23 24 25321 Sheet Number Sheet Issue Date OPN Project No. 26 26 27 27 28 28 29 29 V W X Y Owner All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc. shall retain all common law, statutory and other reserved rights, including the copyright thereto. © 2022 OPN Architects, Inc. 100 Court Ave., Suite 100 Des Moines, IA 50309 P: 515-309-0722 www.opnarchitects.com RYAN COMPANIES 111 E GRAND AVENUE, SUITE 200 DES MOINES, IA 50309 P. 515-309-8500 Project Construction Manager FOTH 8191 BIRCHWOOD COURT, SUITE L JOHNSTON, IA 50131 P. 515-254-1393 Civil Engineer RAKER RHODES ENGINEERING 4717 GRAND AVENUE DES MOINES, IA 50313 P. 515-277-0275 Structural Engineer MORRISSEY ENGINEERING 4940 NORTH 118TH STREET OMAHA, NE 68164 P. 402-491-4144 MEPT Engineer CONFLUENCE 525 17TH STREET DES MOINES, IA 50309 P. 515-288-4875 Landscape Architect A B 4/ 1 9 / 2 0 2 4 4 : 3 2 : 3 5 P M S311 HIGH ROOF FRAMING PLAN 21841001 CONSTRUCTION SET 11/21/2023 WAUKEE PUBLIC SAFETY BUILDING ADDRESS TBD WAUKEE, IA 50263 CITY OF WAUKEE 230 W. HICKMAN ROAD WAUKEE, IA 50263 NORTH 1/8" = 1'-0"A HIGH ROOF FRAMING - AREA A NORTH 1/8" = 1'-0"B HIGH ROOF FRAMING - AREA B NOTES: 1. T/STEEL = 26'-11" U.N.O. 2. NOT ALL DECK PENETRATIONS ARE SHOWN. CONTRACTOR IS RESPONSIBLE FOR COORDINATION SIZES AND LOCATIONS w/ MEP & ARCH DRAWINGS. SEE 6/S401 FOR TYPICAL OPENING DETAIL. NOTES: 1. T/STEEL = 26'-11" U.N.O. 2. NOT ALL DECK PENETRATIONS ARE SHOWN. CONTRACTOR IS RESPONSIBLE FOR COORDINATION SIZES AND LOCATIONS w/ MEP & ARCH DRAWINGS. SEE 6/S401 FOR TYPICAL OPENING DETAIL. 02 ADD 02 ADD 02 ADD 02 ADD 02 ADD 02 ADD 02 ADD 02 ADD Revision Description Date ADD 02 Addendum 10-31-2023 ASI 03 ASI 03-12-2024 PR 03 PR 04-19-2024 1" = 1'-0"1 FULL HEIGHT CURTAIN WALL @ HIGH ROOF 03 PR Waukee Public Safety - Change Request Summary 5/23/2024 Ryan Companies US, Inc. Change Request 019 Change Request Subcontractor Comments Cost Change 19.0 DDVI No response $0.00 19.1 Jordison Construction No response $0.00 19.2 Enterprise Precast No response $0.00 19.3 TSF Structures Add (3-ea) 3/8" bent plates, material $1,040.00 19.4 Northwest Steel Add (3-ea) 3/8" bent plates, installation $660.00 19.5 Forman Ford No response $0.00 19.6 Academy Roofing Add (11-lf) 5-1/2" aluminum metal flashing, material and installation $640.00 19.7 Ford Metro No cost impact $0.00 19.8 Skold Door No response $0.00 19.9 Hilsabeck Schacht No response $0.00 19.10 Elite Fire Sprinkler No response $0.00 19.11 Kruck Plumbing and Heating No response $0.00 19.12 Van Maanen No response $0.00 19.13 TriCity Electric No response $0.00 19.14 Wenthold No response $0.00 19.15 Absolute No response $0.00 19.16 Jordison Construction No response $0.00 19.17 Alpha Landscapes No response $0.00 $2,340.00 Builders Risk (.23% Cost of Work (Estimated)) Excluded per City $0.00 CMa Fee on Cost of Work (3.25%)$76.05 CMa Project Manager Time $0.00 CMa Project Superintendent Time $0.00 Change Request 19 Cost Change Total $2,416.05 Summary: PR-03: Bent steel embeds for curtainwall attachment Change Request 19 Subtotal April 24, 2024 CR#019 Waukee Public Safety Building Job #6173-000 DDVI – General Construction Hilsabeck Schacht - Framing, Drywall & Ceilings Jordison Construction – Building Concrete Elite Fire Sprinkler – Fire Protection Enterprise Precast – Precast Material Kruck Plumbing and Heating - Mechanical & Plumbing TSF Structures - Steel Material & Misc. Metals Van Maanen Electric – Electrical & Communications Northwest Steel - Precast & Steel Erection TriCity Electric – Audio-Visual Forman Ford – Metal Panels Wenthold Excavating – Earthwork & Utilities Academy Roofing – Roofing Absolute Group - SWPPP Ford Metro – Glass & Glazing Jordison Construction – Site Concrete Skold Door – Overhead Doors Alpha Landscapes – Landscape & Irrigation Dear Prime Contractors: We are forwarding this Change Request, briefly described as follows, for your review and response: PR 03 includes the following revisions: Add Structure Detail for Curtain Wall Head This Change Request is further defined by the following attached documents: Drawings: S311, A232 Spec Sections: N/A Please mark the appropriate “Status” below, sign and re turn one copy of this Change Request to Ryan Companies US, Inc. no later than 05/04/2024. Attach a detailed proposal itemizing any cost or schedule impacts resulting from this change. Include reference to this Change Request, quantities (add or deduct), unit prices for labor and materials, and the latest date the proposal may be accepted. A lack of response by the date required above will indicate no change to your Prime Contract Agreement. Your timely response to the Change Request will be appreciated. Please call if you have any questions, or if you need additional information. DO NOT PROCEED; SUBMIT QUOTATION ONLY PROCEED WITH WORK PROCEED WITH WORK NOT TO EXCEED $ AND SUBMIT QUOTATION PROCEED WITH WORK; NO ADDITIONAL COST ANTICIPATED PROCEED WITH WORK; SUBMIT QUOTATION OTHER Sincerely, Acknowledged: RYAN COMPANIES US, INC. By: Company: Date: Status: Proposal attached Jill Boetger No impact on cost or schedule Project Manager II More information or discussion required X Mike Yilek Northwest Steel Erection 4/25/2024 Northwest Steel Erection Inc. 6285 NE Industry Drive Phone: (515) 986-0380 Des Moines, IA 50313 REQUEST FOR CHANGE ORDER #:Date:04/25/24 Job #:231106 Directive:(RFI, ITC, PR, PCO, ADDENDA, FIELD ORDER #, etc.) Brief Description of Work and/or Directive: 6.0 mh x $95.00 / hr.Ironworker $570.00 mh x $92.00 / hr.Operator $0.00 mh x $35.00 / hr.OT Premium $0.00 ea.$600.00 / ea.$0.00 Ea.$200.00 / ea.$0.00 3.0 hr.$15.00 / hr.$45.00 3.0 hr.$15.00 / hr.$45.00 $0.00 Pricing of Add/Deduct Codes (NSE Office Use) Other:$0.00 Labor:$570.00 Equipment $90.00 Total C.O. Request:$660.00 Please prepare the appropriate Change Order and forward copies for execution. Upon request, all necessary back-up can be supplied as needed. Thank you, Mike Yilek Pre-Construction Manager Add BP at (3) Three Curtain Wall Locations at Parapet - 1/S311 PR 03 Welding Machine Jill Boetger (515) 314-1338 Material Delivery & Pick-Up of Equipment Forklift Service Truck/Small Tools & Supplies LABOR EQUIPMENT 1 Contact: Phone: Fax: Waukee Public Safety Facility Ryan Companies 111 E Grand Ave., Suite 200 Des Moines, IA 50309 Project Name: Contract #: Customer: Address: ____________________________________________________________________________________________________ 6361 N.E. 14th Street | Des Moines, IA 50313 |Phone: 515-964-2345 | Fax: 515-964-5514 www.academyroofing.com 1 Des Moines, Iowa 50313 Phone: 515-964-2345 Fax: 515-964-5514 www.Academyroofing.com TO: Ryan Companies 111 E Grand Ave Suite 200, Des Moines, IA 50309 515-309-8500 DATE: May 2, 2024 RE: Waukee Public Safety Building 815 NW 20th St. Waukee, IA 50263 PR 03 We hereby propose to furnish all labor, materials and equipment necessary to perform the following scope of work on the facility mentioned above, in accordance with manufactures specifications: Description of Change: SCOPE OF WORK: Adding 5 1/2" .040 Aluminum L-metal below coping cap (11LF). 1. Additional Material a. 0.040 Aluminum $400.00 2. Additional Labor a. 2 additional labor hours @ $90.00/ Hr. $180.00 3. 15% Mark-up on Materials as per bid. $60.00 4. SUBTOTAL $640.00 COST OF SERVICES: 1. Total Change Order Sum: Six Hundred and Forty Dollars $640.00 Notes: 1. If there is an increase in the actual cost of the labor or materials charge to Academy Roofing & Sheet Metal Co. (ARC) in the excess of 5% subsequent to making this agreement, the price set forth in this agreement shall be increased without the need for a written change order or amendment to the contract to reflect the price increase and additional cost to ARC. ARC will submit written documentation of the increased changes to the Prime Contractor/Owner upon request. As and additional remedy, if the actual cost of any line item increases more than 10% subsequent to the making of this agreement, ARC, at its sole discretion, may terminate the contract for convenience. 2. We reserve the right to update this proposal after 10 days. 3. TERMS: Final payment due at completion of project, Manufacture’s Warranty will be provided after final payment, 18% annual interest charged for all overdue balances. 4. This change order shall be subject to the same terms and conditions as the project contract between Ryan Companies and Academy Roofing & Sheet Metal Co. Acceptance of this proposal shall constitute a contract. GENERAL CONTRACTOR: SUBCONTRACTOR: ACCEPTED: Respectfully Submitted, PRINT NAME: DATE: ACADEMY ROOFING & SHEET METAL CO. April 24, 2024 CR#019 Waukee Public Safety Building Job #6173-000 DDVI – General Construction Hilsabeck Schacht - Framing, Drywall & Ceilings Jordison Construction – Building Concrete Elite Fire Sprinkler – Fire Protection Enterprise Precast – Precast Material Kruck Plumbing and Heating - Mechanical & Plumbing TSF Structures - Steel Material & Misc. Metals Van Maanen Electric – Electrical & Communications Northwest Steel - Precast & Steel Erection TriCity Electric – Audio-Visual Forman Ford – Metal Panels Wenthold Excavating – Earthwork & Utilities Academy Roofing – Roofing Absolute Group - SWPPP Ford Metro – Glass & Glazing Jordison Construction – Site Concrete Skold Door – Overhead Doors Alpha Landscapes – Landscape & Irrigation Dear Prime Contractors: We are forwarding this Change Request, briefly described as follows, for your review and response: PR 03 includes the following revisions: Add Structure Detail for Curtain Wall Head This Change Request is further defined by the following attached documents: Drawings: S311, A232 Spec Sections: N/A Please mark the appropriate “Status” below, sign and re turn one copy of this Change Request to Ryan Companies US, Inc. no later than 05/04/2024. Attach a detailed proposal itemizing any cost or schedule impacts resulting from this change. Include reference to this Change Request, quantities (add or deduct), unit prices for labor and materials, and the latest date the proposal may be accepted. A lack of response by the date required above will indicate no change to your Prime Contract Agreement. Your timely response to the Change Request will be appreciated. Please call if you have any questions, or if you need additional information. DO NOT PROCEED; SUBMIT QUOTATION ONLY PROCEED WITH WORK PROCEED WITH WORK NOT TO EXCEED $ AND SUBMIT QUOTATION PROCEED WITH WORK; NO ADDITIONAL COST ANTICIPATED PROCEED WITH WORK; SUBMIT QUOTATION OTHER Sincerely, Acknowledged: RYAN COMPANIES US, INC. By: Company: Date: Status: Proposal attached Jill Boetger No impact on cost or schedule Project Manager II More information or discussion required TSF Structures, Inc Page 1 of 1 Date: 4/29/2024 CO #: 2 Job #: 1798 Waukee Public Safety Building 6410 7th Street Court SW Suite C Cedar Rapids, IA 52404 Phone: (319)365-7133 Fax: (319)365-2410 Change Order Request Ryan Companies Des Moines 111 East Grand Suite 200 Des Moines, IA 50309 Phone: (515) 309-8500 To:Jill Boetger Subject:PR-03 Structure Detail for Curtainwall Head Change Requested By:Austin Ressler Sent Via:Email Description of Change: Provide (3) new 3/8" bent plates. Labor - $320.00 Material - $598.00 Markup (OH & Profit) - $122.00 The change will cause an increase of $1,040.00 to the contract amount. TSF Structures, Inc A signature below indicates acceptance of all changes shown herein . Any work associated with this change will begin upon receipt of a signed copy of this C.O. in our office. Please respond by 4/30/2024. If the requested response time is not met, the project may be delayed. Accepted By Austin Ressler Jill Boetger Ryan Companies Des Moines w PROPOSAL REQUEST – PR NO. 05 (REV. 1) Please submit an itemized proposal for changes in the Contract Sum and Contract Time for proposed modifications to the Contract Documents described herein. This is not a Change Order, a Construction Change Directive or a direction to proceed with the w ork described in the proposed modifications. Proceeding with the Work prior to authorization indicates your acknowledgement that there will be no change in the Contract Sum or Contract Time. Description: Revisions to casework per owner feedback. 1. Sheet A111B – FLOOR PLAN – AREA B • Add casework elevation T18/A506 to room Print/Copy 302 • Reduce extents of shelf detail in Quartermaster 354 • Add countertop elevation W18/A506 to room Computer Forensics 392 2. Sheet A506 – INTERIOR ELEVATIONS – AREA B & C • T18: Add new elevation for casework and countertop • W18: Add new elevation for 30” deep PLAM countertop with grommets 3. SHEET A 600 – INTERIOR FINISH SCHEDULE • Add PLAM-2 for PLAM to be used for countertop at Computer Forensics 392 OPN Architects, Inc. Date: 04/30/2024 Project: Waukee Public Safety Facility Project number: 21841001 Client: City of Waukee Construction Manager: Ryan Companies R R R R RE F UP V D D D D D D V CR CR DB CR ALIGN 2 COMMAND CONFERENCE 331 OFFICE - CHIEF 373 PRINT / COPY 302 STORAGE 313 SECURE FILES 306 OFFICE - ASST. CHIEF 372 OFFICE 385 ROLL CALL 329 BREAK ROOM 326 SGT. BULLPEN 327 POLICE TRAINING 332 TRAINING STORAGE 333 WELLNESS 311 EVIDENCE PROCESSING 364 BAG & TAG 363 CHIEF CONFERENCE 371 OFFICE - ASST. CHIEF 374 DEPT. STORAGE 353 EQUIPMENT STORAGE 307 PATROL STORAGE 362 REPORTS 328 OPEN OFFICE 390 OFFICE 382 OFFICE 386 OFFICE 384 INVEST. CONFERENCE 391 OFFICE - SGT 394 OFFICE - FUTURE 396 OFFICE - FUTURE 395 SECURED STORAGE 393COMPUTER FORENSICS 392 RESTROOM 399OFFICE 381 OFFICE 383 HIGH VALUE EVIDENCE 367 BULK EVIDENCE 365 EVIDENCE TECH 397 EVIDENCE CUSTODIAN 398 CUSTODIAL 312 DRYING ROOM 366 WOMENS LOCKER 321 MENS LOCKER 322 UNISEX RR/SHOWER 324 UNISEX RR 325UNISEX RR 323 OFFICE 305 OFFICE 304 FAMILY INTERVIEW / F.PRINT 114 INTERVIEW 115 INTERVIEW 116RECORDS TECHS 301 RR / S H W R 32 1 A RR / S H W R 32 1 B RR / S H W R 32 2 A RR / S H W R 32 2 B RR / S H W R 32 2 C FITNESS CENTER 121 TRAINING ROOM 102 MENS RESTROOM 111 WOMENS RESTROOM 113 LOBBY 101 RECEPTION E9 A300 E9 A300 A210 G15 A211 F2 E.1 L 16 W R V A211 A2 R2 A210G2 T22 A300 T22 A300 T13 A300 T13 A300 E 11 0 ' - 0 " OFFICE 303 POLICE ENTRY 361 A8 A315 B11 A313 B1 A313 A22 A315 A7 A314 A19 A314 A1 A252 CORRIDOR 110 CORRIDOR 310 PUBLIC PLAZA 000-W COVERED PATIO 000-E CORRIDOR 300 CORRIDOR 320 CORRIDOR 360 CORRIDOR 340 CORRIDOR 330 CORRIDOR 375 CORRIDOR 380 CORRIDOR 350 CORRIDOR 370 30 1 B 303 306 304 305 313 312 311 322321 331A 333 32 3 32 4 32 5 342 341 IDF 342 353 367 366B 36 4 32 9 A 329B 374373A 383 385 391A 39 0 A 391B 39 6 39 5 39 4 39 3 39 2 399 39 0 B 398 397 40 1 32 1 A 32 1 B 32 2 A 32 2 B 32 2 C OH - 0 9 37 3 B EX - 2 1 4 A411 A22 A411 H21 A410 M19 A411 M22 A400 A19 1 3 6 A233 B21 P1 A310 SIM P7 A310 SIM P7 A310 SIM A350 H3 A351 J22 354 MECH / ELEC. 341 A5 0d A414 A20 A506E20 A20 A506H20 A210 M4 A506 L3 H10 L10 A504 A2 A506 E3 H3 E10 A402 A21 A10 A3 5 5.2 87 9 11 12 15.1151413 F F.1 H K.2 L.2 Q T X Y Z A505 J2 P2 P2 A401 T10 4" 4" 1'-0" 3'-3" 3'-11" 1'-10" 1'-0" 4" 6 ' - 3 " 3 ' - 6 " 6 ' - 6 " 3 ' - 6 " 6 ' - 6 " 3 ' - 6 " 6 ' - 6 " 3 ' - 6 " 6 ' - 6 " 3 ' - 6 " 6 ' - 6 " 3 ' - 6 " 3 ' - 3 " 33 ' - 4 " 6 ' - 8 " 3 0 ' - 0 " 6 ' - 8 " 6 3 ' - 4 " 4 1 / 4 " 2' - 1 0 3 / 4 " 3' - 6 " 6 ' - 6 " 3 ' - 6 " 6 ' - 6 " 3 ' - 6 " 3 ' - 3 " 8" 2 ' - 7 " 3 ' - 6 " 6 ' - 6 " 3 ' - 6 " 6 ' - 6 " 3 ' - 6 " 5 ' - 7 " 1' - 0 " 1'-0" 5'-7" 3'-6" 6'-7" 16'-8" 6'-8" 30'-0" 6'-8" 143'-4" 10'-0"4" 6'-3" 3'-6" 9'-10" 3'-6" 6'-1" 6"4" 6'-3" 3'-6" 9'-10" 3'-6" 6'-6" 3'-6" 9'-10" 3'-6" 6'-6" 3'-6" 6'-6" 3'-6" 6'-6" 3'-6" 6'-6" 3'-6" 6'-6" 3'-6" 6'-6" 3'-6"6'-6" 3'-6" 6'-6" 3'-6" 6'-6" 3'-6" 5'-7"1'-0" 10'-0" 6'-7" 3'-6" 6'-6" 3'-6" 6'-6" 3'-6" 6'-6" 3'-6" 6'-6"3'-6" 6'-6" 3'-6" 6'-6" 3'-6" 6'-6" 3'-6" 8'-11" 1'-0" 113'-4" 3'-4" 3'-4" 3' - 4 " A6 0d A1 0d A4 0d A1 0d 102C 122 104A 104B 123 10 2 D 11 1 11 2 11 3 A1 0d A1 0d A1 0d A2 0d C1 0l 20 1 11 6 11 5 11 4 30 1 A 381 382 384 386 371 372 A1 0d A1 0d A1 0d A1 0d A1 0d A1 0d A1 0d A1 0d A1 0d UNISEX RR 125 SAUNA 126 A1 0d A411 U20 TRAINING STORAGE 123 KITCHENETTE 104 VENDING 103 FAMILY RESTROOM 112 A6 0d A1 0d A1 0d A1 0d A1 0d A2 0d A2 0b A1 0d A1 0d A5 0d A1 0d A1 0d A1 0d A1 0d A1 0d A1 0d A1 0d A1 0d A1 0d A1 0d A1 0d A1 0d A1 0d A1 0d A5 0d A5 0d A2 0d A1 0d A1 0d A1 0d A1 0dA1 0d A1 0d A1 0d A1 0d A1 0d A1 0d A1 0d A1 0d A1 0d A1 0d A1 0d A1 0d A1 0d C1 0l A1 0d C1 0l A1 0d A1 0d A1 2d A1 0d A1 0d A1 0d A1 0d A1 0d A1 0c C1 0l D1 0r CW 0 7 SF 1 SF 1 SF 1 SF 1 SF 1 SF 1 CW 0 4 SF 1 SF 1 SF 1 SF 1 SF 1 SF 1 CW 0 4 CW04 SF1 SF1 SF1 SF1 SF1 SF1 SF1 SF1 SF1 SF1 SF1 SF1 SF1 SF1 SF1 CW04 CW14 CW 1 1 CW 1 1 CW12 SF1 SF1 SF1 SF1 SF1 SF1 SF1 SF1 CW13 A503H11 A11 H2 A2 C1 0l C1 0l C1 0l C1 0l J A401 P21 A506 L18 A506P18 P15 A310 SIM FITNESS STORAGE 122 102B 102A VESTIBULE 100 A350 H12 SIM 09 54.L1A350 H12 SIM MEZZANINE ACCESS 124 K M P 307 QUARTERMASTER 354 SF1 365 331B 332A 332B 110 A450 P17 L.1 G E.2 121A 12 4 125 121B 36 6 A 05 51.B1 B25 A313 A5 0d EX-121C EX-121D EX-101B EX-100 100A EX-101A EX - 3 2 6 EX - 3 6 1 CW07A CW07B CW07C A1 2d A1 0d CW06 C1 0l A15 A315 A1 A315 A252 A21 A402 A7 A1 A351 R22 A350 A21 A351 B22 A350 H21 SIM A350 H21 SIM A350 H21 SIM 12'-2" 6'-8" 30'-0" 6'-8" 39'-4" 5'-0" 75'-4" 3'-4" 2'-4" 6'-0" 6'-0" 6'-0" 7.3 M.1 D1 0r D1 0r A252 V1 P10 11 ' - 7 3 / 4 " 1 1 ' - 8 " 8 ' - 1 0 " 12'-2" 6'-8" 30'-0" 6'-8" 39'-4" 5'-0" 77'-0" 5'-0" 16'-0" 1'-0" 10'-0" 1'-0" 14'-8" 15'-4" 10 ' - 9 3 / 4 " 1 0 ' - 8 " 1 0 ' - 8 " 10 ' - 8 " 1 0 ' - 8 " 1 0 ' - 9 3 / 4 " 15'-10" 23'-6" 22'-11" 17'-1" 12'-0" 12'-0" 12'-8" 15 ' - 9 3 / 4 " 8 ' - 6 " 7 ' - 1 0 " 8'-4" 3'-8" A1 0d 16 ' - 8 " 1 5 ' - 5 3 / 4 " 16 ' - 8 " 1 5 ' - 5 3 / 4 " 8' - 8 " 1 4 ' - 2 1 / 2 " 8 ' - 8 " 2'-2" A1 0d A1 0d 12'-2" 6'-8" 30'-0" 6'-8" 5'-2" 3'-4"1'-3"3'-4" 17'-7" 3'-4" 5'-4" 5'-0" 81'-0" 6'-0" 6'-0" 6'-0" 32 ' - 1 3 / 4 " 10 ' - 4 1 / 4 " 9 ' - 8 7 / 8 " 9 ' - 8 7 / 8 " 2 1 ' - 9 1 / 2 " 22'-9 3/8" 9'-8 3/8" 9'-10" 9'-10" 8' - 0 " 7' - 0 " 1 4 ' - 1 0 " 10 ' - 0 " 1 0 ' - 0 " 9 ' - 1 0 " 4' - 1 0 " 2 ' - 3 " EQ 1 4 ' - 0 " E Q EQ 1 4 ' - 0 " E Q 5'-11" 2'-2"2'-2" 13'-4" 10 ' - 2 " 8" 2 9 ' - 0 " 6 ' - 8 " 3 0 ' - 0 " 6 ' - 8 " 2 9 ' - 0 " 8 " 14'-8" 18'-11" 9' - 8 " 12 ' - 0 " 2'-0" 30 ' - 0 " A1 0d A1 0d 15'-6" 14'-6" 22'-10" 19'-0" 24'-4" 4 1 / 4 " A351 R22 SIM A401 T21 M3 A801 A2 0b A1 0d C1 0l C1 0l EQ 4'-8" EQ EQ 4'-8" EQ 3' - 0 " 3' - 0 " AED A1 0e A1 0d A1 0d M3 A801 A350 H12 SIM A350 H12 SIM FEC 10'-0" 13'-4" 13'-4" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" A111A A111A A111C A111C -3" 03 31.B2 321C EX-322D A351 R3 Q14 A311 104C 10 51.A1 10 51.A1 10 ' - 0 " 10 44.A1 10 44.A1 10 44.A1 10 44.A110 44.A1 10 44.A1 10 44.A1 10 44.A1 10 44.A1 10 44.A3 10 44.A1 AED 4" 2 1/4" 12'-2" 6'-8" 30'-0" 6'-5 3/4" 15'-6" 10'-3 1/2" 15'-9 3/4" 32'-10" 11'-8 3/8" 4'-8" 16'-3" 4'-8" 8'-1 1/2" 3'-4" 20'-4 1/4" 1' - 6 " 5 ' - 0 " 1 1 ' - 1 " 5 ' - 0 " 1' - 1 " 5' - 4 " 11 " 5 ' - 0 " 5 ' - 8 " 5 ' - 0 " 5 ' - 8 " 5 ' - 0 " 1 ' - 9 " TYP. 10" 1' - 6 " 5 ' - 0 " 1 7 ' - 0 " 5 ' - 0 " 1 ' - 6 " 3' - 9 " 5 ' - 0 " 4 ' - 9 " 5 ' - 0 " 4 ' - 1 0 " 5 ' - 0 " 1 ' - 6 " 3' - 1 " 3 ' - 4 " 6 ' - 7 " 3 ' - 4 " 6 ' - 5 " 3' - 4 " 3 3 ' - 1 1 " 3 ' - 4 " 3 ' - 8 " 3 ' - 4 " 1 ' - 4 " 3 ' - 4 " 4 ' - 4 " 9' - 4 " 3' - 4 " 1 ' - 4 " 3 ' - 4 " 6 ' - 0 " 3' - 4 " 3 ' - 6 " 3 ' - 4 " 5 ' - 1 1 " A504 U2 A505 E9A9 A504 K2E2 A1 0d A6 0d 08 34.A1 22 45.B1 MB-1 MB-1 MB-1 MB-1 MB-1 MB -1 MB -1 MB-1 MB-1 MB -1 MB -1 MB -1 MB-1 MB-1 MB -2 MB -2 MB -2 MB -2 MB -2 MB -2 MB -2 MB -2 MB -2 MB -2 MB -2 MB -2 MB -2 MB-1 MB-1 MB-2 MB-1 MB -2 MB -2 B20 A313 Q11 A313 F. O . G . 2' - 8 " 1 ' - 0 " F. O . S . 6' - 2 " 10 ' - 8 1 / 2 " 1 8 ' - 2 " PROVIDE (2) LAYERS 1/2" GYP. TO FLUSH WALL BETWEEN AREAS A AND B UP TO 14'-0" AFF P7 A310 SIM 3' - 8 " 6 ' - 0 " 4 ' - 0 " 1 0 ' - 0 " 8 ' - 6 " 1 ' - 6 " 1 3 ' - 4 " 1 ' - 6 " 8 ' - 6 " 1 0 ' - 0" 4 ' - 0 " 6 ' - 0 " 3 ' - 8 " 1 ' - 0 " 7 ' - 9 3 / 4 " 1 7 ' - 1 0 1 / 4 " 4 ' - 0 " 3 1 ' - 5 3 / 4 " 7 ' - 1 0 1 / 2 " 2 9 ' - 3 1 / 2 " 7 ' - 8 1 / 4 " 3 1 ' - 8 " 6 ' - 8 " 11'-6" 30'-0" 30'-0" 18'-0" 12'-0" 7'-2" 3'-6" 19'-2" 29'-4" 7'-4" 2'-8" 9'-0 1/4" 26'-3 3/4"8" 10'-0" 3'-10" 10 ' - 0 " 2 0 ' - 0 " 3 ' - 4 " 1 3 ' - 4 " 3 ' - 4 " 2 0 ' - 0 " 3 3 ' - 4 " 3 ' - 4 " 3 ' - 4 " 3'-4" 4'-5" 6'-6" FBFB FB FB FB FB FBFBFBFB FB FB FB FB FB FB FB FB FB FB FB FB FB FBFBFB FB FB FB FB FB FB FBFB FB C1 0l A4 0d C1 0l 06 10.A1 06 10.A1 ADD 03 158.A 48-34-23 06 61.C1 ADD 03 B4 A551 ADD 03 ASI 03 10 44.C1 ASI 03 ASI 06 ASI 06 ASI 07 ASI 07 A506 T18 PR 05 PR 05 2' - 6 " A506 W18 PR 05 GENERAL NOTES 1. DIMENSIONS ARE MEASURED FACE- OF-FINISH TO FACE-OF-FINISH OR ROUGH MASONRY / PRECAST CONCRETE OPENING UNLESS NOTED OTHERWISE - TYPICAL FOR ALL DRAWINGS. 2. IN THE EVENT OF A DISCREPANCY BETWEEN ARCHITECTURAL AND CONSULTANT DRAWINGS, NOTIFY ARCHITECT IMMEDIATELY PRIOR TO COMMENCING WORK - TYPICAL FOR ALL DRAWINGS. 3. REFER TO LIFE SAFETY AND CODE SUMMARY DRAWINGS FOR FIRE RATED WALL LOCATIONS. 4. REFER TO SHEET A002 FOR PARTITION WALL TYPES. 5. ALL PENETRATIONS IN FIRE RATED FLOORS AND WALLS MUST BE SEALED WITH APPROPRIATE FIRESTOPPING SYSTEM. PARTITIONS SHOWN TO BE FIRE RATED MUST BE CONSTUCTED ACCORDING TO THE LISTED UL ASSEMBLY DESIGNATION NUMBER. 6. ALL INTERIOR WALL TYPES ARE TYPE A1,d,0, UNLESS NOTED OTHERWISE. 7. AT METAL FRAMED PARTITIONS PROVIDE CONCEALED, FLAT STRAP BLOCKING AT ALL ACCESSORIES AND CASEWORK LOCATIONS. EXTEND BLOCKING TO NEAREST ADJACENT STUD, A MINIMUM OF 6" BEYOND EACH END AND 6" ABOVE AND BELOW ALL ACCESSORIES. 8. AT METAL FRAMED PARTITIONS WITH SOUND ATTENUATION BLANKETS ARE TO HAVE ACCOUSTICAL SEALANT AT TOP AND BOTTOM OF PARTITIONS AND AT ALL WALL PENETRATIONS. 9. ALL DOOR FRAMES LOCATED 4" FROM FINISH FACE OF WALL UNLESS NOTED OTHERWISE. 10. ALL EXPOSED CMU CORNERS TO BE BULLNOSED UNLESS NOTED OTHERWISE. 11. REFER TO INTERIOR ELEVATIONS, FINISH PLANS, FINISH SPECIFICATIONS, AND ROOM FINISH SCHEDULE FOR ADDITIONAL FINISH INFORMATION AND REMARKS. 12. REFER TO ENLARGED PLANS FOR ADDITIONAL WALL TYPES, DIMENSIONS, AND KEYNOTES. 13. ALL EXTERIOR PRECAST WALLS TO BE FURRED WITH TYPE C1,l,0, UNLESS NOTED OTHERWISE. 14. ALL EXTERIOR STEEL EXPOSED TO VIEW TO BE PAINTED WITH HIGH- PERFORMANCE COATING 2 A9 A300 E.1 L A210G2 T22 A300 T22 A300 E A8 A315 B11 A313 B1 A313 A22 A315 A7 A314 A19 A314 1 3 A210 M4 5 87 11 12 F F.1 H K.2 L.2 A503H11 A11 H2 A2 J A210 A2 OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW A211 U14 MECHANICAL 218 GALV. STEEL STAIR AND RAILING K M A450 P22 OPEN TO BELOW OPEN TO BELOW L.1 G E.2 B25 A313 A15 A315 A1 A315 7.3 M.1 05 51.L1 Q17 A312 SIM FE C 09 54.L1 09 54.L1 A1 0d OPEN A2 0d A1 0e A1 0d A1 0d A1 0e A2 0d A1 0d A1 0d A2 0d A2 0e B20 A313 Q11 A313 7'-2" 3'-6" 19'-2" 39'-4" 9'-0 1/4" 26'-3 3/4" 10'-8" 3'-10" 3' - 8 " 6' - 0 " 4 ' - 0 " 1 0 ' - 0 " 8 ' - 6 " 1 ' - 6 " 1 3 ' - 4 " 1 ' - 6 " 8 ' - 6 " 1 0 ' - 0 " 4 ' - 0" 6 ' - 0 " 3 ' - 8 " 1 ' - 0 " ASI 06 ASI 06 A 19181716151413121110987654 B C D E F G H J K L M N P Q PR I N T E D : R S T U 20 21 22 23 24 25 Sheet Name Key Plan 321 19181716151413121110987654 20 21 22 23 24 25321 Sheet Number Sheet Issue Date OPN Project No. 26 26 27 27 28 28 29 29 V W X Y Owner All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc. shall retain all common law, statutory and other reserved rights, including the copyright thereto. © 2022 OPN Architects, Inc. 100 Court Ave., Suite 100 Des Moines, IA 50309 P: 515-309-0722 www.opnarchitects.com RYAN COMPANIES 111 E GRAND AVENUE, SUITE 200 DES MOINES, IA 50309 P. 515-309-8500 Project Construction Manager FOTH 8191 BIRCHWOOD COURT, SUITE L JOHNSTON, IA 50131 P. 515-254-1393 Civil Engineer RAKER RHODES ENGINEERING 4717 GRAND AVENUE DES MOINES, IA 50313 P. 515-277-0275 Structural Engineer MORRISSEY ENGINEERING 4940 NORTH 118TH STREET OMAHA, NE 68164 P. 402-491-4144 MEPT Engineer CONFLUENCE 525 17TH STREET DES MOINES, IA 50309 P. 515-288-4875 Landscape Architect B 6/ 1 0 / 2 0 2 4 1 : 5 3 : 2 9 P M A111B FLOOR PLAN - AREA B 21841001 CONSTRUCTION SET 11/21/2023 WAUKEE PUBLIC SAFETY BUILDING 815 NW 20th STREET WAUKEE, IA 50263 CITY OF WAUKEE 230 W. HICKMAN ROAD WAUKEE, IA 50263 N 1/8" = 1'-0"A3 LEVEL 1 FLOOR PLAN - AREA B KEYNOTE LEGEND 03 31.B2 DEPRESSED CONCRETE SLAB - SEE STRUCTURAL 05 51.B1 CONCRETE PAN FILLED STAIR W/ GALV. STEEL RAILING 05 51.L1 ROOF ACCESS LADDER 06 10.A1 PROVIDE CONSTRUCTION PANEL MOUNTING BOARDS AT ALL WALLS 06 61.C1 QUARTZ (Q-1) COUNTERTOP 08 34.A1 BI-PARTING ABOVE COUNTER POCKET DOOR, SEE HARDWARE SPECIFICATION 09 54.L1 ALUMINUM LOUVER SUNSHADE SYSTEM 10 44.A1 RECESSED FIRE EXTINGUISHER CABINET 10 44.A3 SURFACE MOUNT FIRE EXTINGUISHER 10 44.C1 KNOX BOX 10 51.A1 PERSONAL STORAGE LOCKERS W/ INTEGRATED BENCH AND POWER CONNECTIONS - BY OTHERS 22 45.B1 EYEWASH STATION - SEE MECHANICAL N 1/8" = 1'-0"P16 MEZZANINE FLOOR PLAN - AREA B Revision Description Date ADD 03 Addendum 11/14/23 ASI 03 ASI 3/12/2024 ASI 06 ASI 4/12/2024 ASI 07 ASI 4/29/2024 PR 05 PR - REV. 1 4/30/2024 LEVEL 1 0" EQ 28'-4" EQ 3' - 0 " T Y P . LINEAR WOOD BAFFLE -SEE RCP FOR TYPE QUARTZ (Q-1) COUNTERTOP & 4" BACKSPLASH (PLAM-1) BASE CABINETS 102.A 34-34-24 102.A 34-34-24 102.A 34-34-24 102.A 34-34-24 102.A 34-34-24 102.A 34-34-24 102.A 34-34-24 102.A 34-34-24 102.A 34-34-24 OPEN OPEN 12" WALL PROTECTION STRIP -SEE FINISH PLANS & SPECIFICATIONS PT-4 10'-0" 102.A 34-34-24 2' - 1 0 " PT-1 TO INSIDE CORNER PT-1 TO INSIDE CORNER 28'-9 1/2" LEVEL 1 0" WALL BASE AS SCHEDULED LINEAR WOOD BAFFLE -SEE RCP FOR TYPE EQ VERIFY W/ SUPPLIER 12'-0" EQ VE R I F Y W / S U P P L I E R 6' - 1 0 " PASS-THRU KEYLESS EVIDENCE LOCKERS W/ ELECTRONIC CONTROLS, COORDINATE CONNECTIONS W/ SUPPLIER -OFCIOPENOPEN 10'-0" 12" WALL PROTECTION STRIP -SEE FINISH PLANS & SPECIFICATIONS 3' - 0 " T Y P . GYPSUM WALL BOARD, PT AS SCHEDULED LEVEL 1 0" 2' - 1 0 " LINEAR WOOD BAFFLE -SEE RCP FOR TYPE 102.A 36-34-24 102.A 36-34-24 102.A 36-34-24 102.A 33-34-24 102.A 36-34-24 102.A 36-34-24 102.A 36-34-24 QUARTZ (Q-1) COUNTERTOP & 4" BACKSPLASH (PLAM-1) BASE CABINETS OPENOPEN 10'-0" PT-4 20'-11 1/2" 7'-10" 100.A 45-34-24 100.A 45-34-24 A551 B21 (PLAM-1) MAIL STORAGE 80 EQUAL SLOTS, SEE CASEWORK DETAILS 12" WALL PROTECTION STRIP -SEE FINISH PLANS & SPECIFICATIONS 3' - 0 " PT-1 TO INSIDE CORNER PT-1 TO INSIDE CORNER WALL BASE AS SCHEDULED LEVEL 1 0" EQ 13'-9"EQ 2' - 1 0 " (PLAM-1) BASE CABINETS QUARTZ (Q-1) COUNTERTOP & 4" BACKSPLASH WALL BASE AS SCHEDULED 331A 102.A 33-34-24 102.A 33-34-24 102.A 33-34-24 102.A 33-34-24 331B 102.A 33-34-24 14'-0" PT-4 6'-2 1/2" 15'-2 1/2" 6'-2 1/2" 7" 14'-0 1/2" 7" PT-1 TO INSIDE CORNER PT-1 TO INSIDE CORNER 4" EXTRUDED CEILING SYSTEM EDGE TRIM (ARMSTRONG "AXIOM" OR EQUAL) T9 A720 GYPSUM WALL BOARD, PT AS SCHEDULED LEVEL 1 0" EQ EQ MONITOR AND RECESSED MOUNTING BOX BY A/V -VERIFY MOUNTING HEIGHT QUARTZ (Q-1) COUNTERTOP & 4" BACKSPLASH (PLAM-1) BASE CABINETS WALL BASE AS SCHEDULED 2' - 1 0 " GYPSUM WALL BOARD, PT AS SCHEDULED LEVEL 1 0" MONITOR AND RECESSED MOUNTING BOX BY A/V -VERIFY MOUNTING HEIGHT EQEQ (PLAM-1) BASE CABINETS QUARTZ (Q-1) COUNTERTOP & 4" BACKSPLASH WALL BASE AS SCHEDULED 2' - 1 0 " GYPSUM WALL BOARD, PT AS SCHEDULED LEVEL 1 0" IG-1*IG-1*IG-1* P1 A310 SIM TY P . 8" WALL BASE AS SCHEDULED ALUMINUM STOREFRONT SYSTEM 4" EXTRUDED CEILING SYSTEM EDGE TRIM (ARMSTRONG "AXIOM" OR EQUAL) ROLLER SHADE -SEE RCPT9 A720 GYPSUM WALL BOARD, PT AS SCHEDULED LEVEL 1 0" 333 MONITOR AND RECESSED MOUNTING BOX BY A/V -VERIFY MOUNTING HEIGHT EQ VERIFY EQ WALL BASE AS SCHEDULED HOLLOW METAL DOOR & FRAME - SEE SCHEDULE GYPSUM WALL BOARD, PT AS SCHEDULED LEVEL 1 0" EQ VERIFY EQ QUARTZ (Q-1) COUNTERTOP & 4" BACKSPLASH (PLAM-1) BASE CABINETS WALL BASE AS SCHEDULED MONITOR AND RECESSED MOUNTING BOX BY A/V -VERIFY MOUNTING HEIGHT 2' - 1 0 " GYPSUM WALL BOARD, PT AS SCHEDULED LEVEL 1 0" EQVERIFYEQ WALL BASE AS SCHEDULED (PLAM-1) BASE CABINETS QUARTZ (Q-1) COUNTERTOP & 4" BACKSPLASH MONITOR AND RECESSED MOUNTING BOX BY A/V -VERIFY MOUNTING HEIGHT 2' - 1 0 " GYPSUM WALL BOARD, PT AS SCHEDULED LEVEL 1 0" EQ 13'-9" EQ 6' - 2 " 2 ' - 1 0 " (PLAM-1) BASE CABINETS QUARTZ (Q-1) COUNTERTOP & 4" BACKSPLASH 102.A 33-34-24 102.A 33-34-24 102.A 33-34-24 102.A 33-34-24 332B 332APT-4 102.A 33-34-24 WALL BASE AS SCHEDULED 6'-9 1/2" 15'-2 1/2" 6'-9 1/2" 7" 14'-0 1/2" 7" PT-1 TO INSIDE CORNER PT-1 TO INSIDE CORNER GYPSUM WALL BOARD, PT AS SCHEDULED LEVEL 1 0" QUARTZ (Q-1) COUNTERTOP & 4" BACKSPLASH (PLAM-1) BASE CABINETS 391B REFRIGERATOR, OFCI 102.A 36-34-24 102.A 36-34-24 102.A 36-34-24 102.A 36-34-24 391A M3 A801 2'-1 1/2" 12'-1" M3 A801 6' - 2 " 2 ' - 1 0 " ROLLER SHADE -SEE RCPROLLER SHADE -SEE RCP PT-4 WALL BASE AS SCHEDULED 7 1/4" 14'-2 1/2" 7 1/4" EQ 15'-5" EQ PT-1 TO INSIDE CORNER PT-1 TO INSIDE CORNER GYPSUM WALL BOARD, PT AS SCHEDULED LEVEL 1 0" (PLAM-1) BASE CABINETS STAINLESS STEEL COUNTERTOP & 4" BACKSPLASH 2' - 1 0 " 102.A 39-34-29 102.A 39-34-29 102.A 39-34-29 102.A 39-34-29 102.A 39-34-29 OPEN EQ 16'-3" EQ 2'-5" 1" EQ EQ MONITOR AND RECESSED MOUNTING BOX BY A/V -VERIFY MOUNTING HEIGHT GYPSUM WALL BOARD, PT AS SCHEDULED LEVEL 1 0" 102.A 36-34-29 102.A 36-34-29 102.A 36-34-29 102.A 36-34-29 102.A 36-34-29 2'-5" EQ 15'-0" EQ STAINLESS STEEL COUNTERTOP & 4" BACKSPLASH (PLAM-1) BASE CABINETS 2' - 1 0 " MONITOR AND RECESSED MOUNTING BOX BY A/V -VERIFY MOUNTING HEIGHT EQ EQ EXTERIOR GLAZING LEGEND 1" INSULATED VISION GLAZINGIG-1 IG-2 1" INSULATED SPANDREL GLAZING MP METAL PANEL W/ INSULATED BACKPAN IBP INSULATED BACKPAN NOTE: (*) -DENOTES TEMPERED GLAZING, TYP. MULLION LEGEND M1 -1" STANDARD FLAT MULLION CAP (TYP. UNLESS NOTED OTHERWISE) -SEE DETAIL G21/A232 M2 -STRUCTURAL GLAZED SILICONE JOINT -SEE DETAIL G11/A232 M3 -STRUCTURALLY GLAZED SILICONE 90- DEGREE OUTSIDE CORNER TRIM -SEE DETAIL R21/A233 INTERIOR GLAZING LEGEND NON-INSULATED VISION GLAZINGG1 G3 NON-INSULATED BALLISTICS RATED GLAZING NOTE: (*) -DENOTES TEMPERED GLAZING, TYP. SEE SPECIFICATION FOR GLAZING THICKNESS REQUIREMENTS INTERIOR GLAZING IS TYPE G-1*, U.N.O. NON-INSULATED BACK-PAINTED GLAZINGG2 G4 NON-INSULATED LAMINATED GLAZING WITH COLORED PLASTIC INTERLAYER LEVEL 1 0" 102.A 33-34-24 102.A 33-34-24 102.A 33-34-24 102.A 33-34-24 302 33-30-12 302 33-30-12 302 33-30-12 302 33-30-12 2' - 1 0 " 1 ' - 8 " 2 ' - 6 " EPT-2 STAINLESS STEEL COUNTERTOP & 4" BACKSPLASH (PLAM-1) BASE CABINETS (PLAM-1) UPPER CABINETS 11'-2" UNDERCABINET LIGHT FIXTURE -SEE ELECTRICAL LEVEL 1 0" 2' - 1 0 " 1 ' - 8 " 2 ' - 6 " 102.A 42-34-24 102.A 42-34-24 302 42-30-12 302 42-30-12 EPT-2 7'-2" (PLAM-1) BASE CABINETS (PLAM-1) UPPER CABINETS STAINLESS STEEL COUNTERTOP & 4" BACKSPLASH UNDERCABINET LIGHT FIXTURE -SEE ELECTRICAL EQ.51 LEVEL 1 0" 102.A 39-34-24 102.A 39-34-24 102.A 39-34-24 POLICE FURNISHINGS BASE CABINETS 2' - 1 0 " EQ 9'-9" EQ EPT-1 D2 0r POLICE FURNISHINGS STAINLESS STEEL COUNTERTOP & 4" BACKSPLASH ADD 02 LEVEL 1 0" PT-4 102.A 36-34-24 102.A 36-34-24 102.A 36-34-24 102.A 36-34-24 254.A 30-34-24 EQ14'-6"EQ 2' - 1 0 " (PLAM-1) BASE CABINETS QUARTZ (Q-1) COUNTERTOP & 4" BACKSPLASH WALL BASE AS SCHEDULED LEVEL 1 0" A1 A403 SIM 30" DEEP V.I.F. 22'-3 3/4" PROVIDE (5) GROMMETS IN COUNTERTOP -EQUALLY SPACED 2' - 1 0 " PLAM (PLAM-2) COUNTERTOP & 4" BACKSPLASH A 19181716151413121110987654 B C D E F G H J K L M N P Q PR I N T E D : R S T U 20 21 22 23 24 25 Sheet Name Key Plan 321 19181716151413121110987654 20 21 22 23 24 25321 Sheet Number Sheet Issue Date OPN Project No. 26 26 27 27 28 28 29 29 V W X Y Owner All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc. shall retain all common law, statutory and other reserved rights, including the copyright thereto. © 2022 OPN Architects, Inc. 100 Court Ave., Suite 100 Des Moines, IA 50309 P: 515-309-0722 www.opnarchitects.com RYAN COMPANIES 111 E GRAND AVENUE, SUITE 200 DES MOINES, IA 50309 P. 515-309-8500 Project Construction Manager FOTH 8191 BIRCHWOOD COURT, SUITE L JOHNSTON, IA 50131 P. 515-254-1393 Civil Engineer RAKER RHODES ENGINEERING 4717 GRAND AVENUE DES MOINES, IA 50313 P. 515-277-0275 Structural Engineer MORRISSEY ENGINEERING 4940 NORTH 118TH STREET OMAHA, NE 68164 P. 402-491-4144 MEPT Engineer CONFLUENCE 525 17TH STREET DES MOINES, IA 50309 P. 515-288-4875 Landscape Architect B C 6/ 1 0 / 2 0 2 4 1 : 5 3 : 3 4 P M A506 INTERIOR ELEVATIONS - AREA B & C 21841001 CONSTRUCTION SET 11/21/2023 WAUKEE PUBLIC SAFETY BUILDING 815 NW 20th STREET WAUKEE, IA 50263 CITY OF WAUKEE 230 W. HICKMAN ROAD WAUKEE, IA 50263 1/4" = 1'-0"A20 INTERIOR ELEVATION - BAG & TAG 1/4" = 1'-0"E20 INTERIOR ELEVATION - DROP LOCKERS 1/4" = 1'-0"H20 INTERIOR ELEVATION - PATROL STORAGE 1/4" = 1'-0"E3 INTERIOR ELEVATION - COMMAND CONFERENCE 331 - EAST 1/4" = 1'-0"A3 INTERIOR ELEVATION - COMMAND CONFERENCE 331 - NORTH 1/4" = 1'-0"A10 INTERIOR ELEVATION - COMMAND CONFERENCE 331 - SOUTH 1/4" = 1'-0"E10 INTERIOR ELEVATION - COMMAND CONFERENCE 331 - WEST 1/4" = 1'-0"L3 INTERIOR ELEVATION - POLICE TRAINING 332 - EAST 1/4" = 1'-0"H3 INTERIOR ELEVATION - POLICE TRAINING 332 - NORTH 1/4" = 1'-0"H10 INTERIOR ELEVATION - POLICE TRAINING 332 - SOUTH 1/4" = 1'-0"L10 INTERIOR ELEVATION - POLICE TRAINING 332 - WEST 1/4" = 1'-0"L18 INTERIOR ELEVATION - INVEST. CONFERENCE 391 - EAST 1/4" = 1'-0"P18 INTERIOR ELEVATION - EVIDENCE PROCESSING 364 - WEST 1/4" = 1'-0"P10 INTERIOR ELEVATION - EVIDENCE PROCESSING 364 - NORTH KEYNOTE LEGEND 05 58.A2 STAINLESS STEEL COUNTERTOP & 4" BACKSPLASH 06 41.A3 (PLAM-1) UPPER CABINETS 06 41.B1 (PLAM-1) BASE CABINETS 06 61.C2 QUARTZ (Q-1) COUNTERTOP & 4" BACKSPLASH 08 11.A1 HOLLOW METAL DOOR & FRAME - SEE SCHEDULE 08 43.A1 ALUMINUM STOREFRONT SYSTEM 09 29.A3 GYPSUM WALL BOARD, PT AS SCHEDULED 09 53.C1 4" EXTRUDED CEILING SYSTEM EDGE TRIM (ARMSTRONG "AXIOM" OR EQUAL) 09 54.D LINEAR WOOD BAFFLE - SEE RCP FOR TYPE 09 70.A1 WALL BASE AS SCHEDULED 10 26.B2 12" WALL PROTECTION STRIP - SEE FINISH PLANS & SPECIFICATIONS 10 51.A3 PASS-THRU KEYLESS EVIDENCE LOCKERS W/ ELECTRONIC CONTROLS, COORDINATE CONNECTIONS W/ SUPPLIER - OFCI 11 31.A1 REFRIGERATOR, OFCI 12 24.A1 ROLLER SHADE - SEE RCP 26 51.F1 UNDERCABINET LIGHT FIXTURE - SEE ELECTRICAL 27 40.A1 MONITOR AND RECESSED MOUNTING BOX BY A/V - VERIFY MOUNTING HEIGHT 1/4" = 1'-0"P3 INTERIOR ELEVATION - ARMORY 404 - EAST 1/4" = 1'-0"T3 INTERIOR ELEVATION - ARMORY 404 - WEST 1/4" = 1'-0"T10 INTERIOR ELEVATION - PROCESSING 430 - EAST Revision Description Date ADD 02 Addendum 10/31/23 PR 05 PR - REV. 1 4/30/2024 1/4" = 1'-0"T18 INTERIOR ELEVATION - PRINT/COPY - NORTH PR 05 1/4" = 1'-0"W18 INTERIOR ELEVATION - COMPUTER FORENSICS - NORTH INTERIOR FINISH SPECIFICATIONS ACB-1 MANUFACTURER: ARMSTRONG STYLE:FELTWORKS HOOK-ON PEAKS AND VALLEYS SIZE: 12"X96" (8' PEAKS AND VALLEYS KIT) FIELD:18'X28' -SEE RCP FOR LAYOUT GRID:ALUMINUM SUSPENSION BAR BY MANUFACTURER GRID COLOR: BLACK COLOR: SMOKE APPLICATION: DAYROOM ACOUSTIC CEILING BAFFLES: ACB-2 MANUFACTURER: CERTAINTEED STYLE:HIGH PROFILE SERIES BEAM SIZE: 2" X 8" GRID: UNISTRUT MOUNT GRID COLOR: BLACK COLOR: NORTHWEST MOUNTAIN HEMLOCK W/ MATCHING ENDCAPS APPLICATION: CORRIDORS ACOUSTIC CEILING PANELS: ACP-1 MANUFACTURER: ARMSTRONG STYLE:OPTIMA TEGULAR SIZE: 24" X 24" EDGE TRIM:4" AXIOM GRID: 9/16" SUPRAFINE XL COLOR: WHITE APPLICATION: TYPICAL CEILING ACP-2 MANUFACTURER: ARMSTRONG STYLE:OPTIMA TEGULAR SIZE: VARIES, SEE RCP EDGE TRIM: 4" AXIOM GRID: 9/16" SUPRAFINE XL COLOR: WHITE APPLICATION: BREAKROOM ACP-3 MANUFACTURER: ARMSTRONG STYLE:CALLA TEGULAR SIZE: 24" X 24" EDGE TRIM: FULL PERIMETER GRID: 9/16" SUPRAFINE XL -BLACK COLOR: BLACK APPLICATION: F.A.T.S. ROOM ACOUSTIC WALL PANEL: AWP-1 PRODUCT: FABRIC WRAPPED PANEL THICKNESS:2" EDGE: SQUARE SIZE: SEE ELEVATION FABRIC: GUILFORD OF MAINE STYLE: ANCHORAGE 2335 (66") / OPEN HOUSE 2334 (54") COLOR: WHITE 2664 APPLICATION: LOBBY, TRAINING ROOM, FITNESS ROOM CARPET: CPT-1 MANUFACTURER: SHAW CONTRACT STYLE:ABOVE TILE; 5T392 COLOR: SHADE SIZE:9" X 36" INSTALL METHOD: STAGGER APPLICATION: SEE FINISH FLOOR PLANS CPT-2 MANUFACTURER: SHAW CONTRACT STYLE:HABITAT TILE; 5T392 COLOR: SHADE SIZE:9" X 36" INSTALL METHOD: STAGGER APPLICATION: SEE FINISH FLOOR PLANS CORNER GUARD: CG-1 COLOR: STAINLESS STEEL SIZE: 2" WING APPLICATION: OUTSIDE GYP. CORNERS; MOUNT DIRECTLY ABOVE BASE TO THE PAINT LINE TRANSITION FIBER GLASS REINFORCEMENT PANEL: FRP MANUFACTURER: PANOLAM STYLE:FIBERGLASS REINFORCED PLASTICS COLOR: WHITE SIZE: 4' X 8' FINISH:EMBOSSED APPLICATION:AT MOP SINKS FILM: FILM MANUFACTURER: 3M STYLE:WINDOW FILM DESIGN: CUSTOM APPLICATION: FULL HEIGHT AT AREAS INDICATEDGROUT: G-1 MANUFACTURER: BOSTIK TRUCOLOR COLOR: MOBE PEARL H145 APPLICATION: FLOOR RESTROOM TILE G-2 MANUFACTURER: BOSTIK TRUCOLOR COLOR: CLASSIC BONE H158 APPLICATION: WALL RESTROOM TILE G-3 MANUFACTURER: BOSTIK TRUCOLOR COLOR: FRENCH GRAY H142 APPLICATION: WALL BACKSPLASH METAL TRANSITIONS: MT-1 MANUFACTURER: SCHLUTER STYLE: JOLLY COLOR: ANODIZED ALUMINUM FINISH:BRUSHED/SATIN APPLICATION: TILE OUTSIDE CORNERS MT-2 MANUFACTURER: SCHLUTER STYLE: RENO-U COLOR: ANODIZED ALUMINUM FINISH:BRUSHED/SATIN APPLICATION: SC TO CPT, SC TO RF-X MT-3 MANUFACTURER: SCHLUTER STYLE: JOLLY COLOR: ANODIZED ALUMINUM FINISH:BRUSHED/SATIN APPLICATION: EXPOSED EDGE RF-1 PAINT: PT-1 MANUFACTURER: BENJAMIN MOORE COLOR: CHANTILLY LACE APPLICATION: FIELD PAINT -U.N.O., OTS -U.N.O NOTE: PAINT PRODUCT INFO IS FOR COLOR REFERENCE ONLY. REFER TO SPECIFICATIONS FOR SPECIFIC PRODUCT INFO. EPT-X REFERS TO EPOXY PAINT PT-2 MANUFACTURER: SHERWIN WILLIAMS COLOR: REPOSE GRAY SW 7015 APPLICATION: INDOOR GARAGE, APPARATUS BAY INTERIOR, BOH AREAS PT-3 NOT USED PT-4 MANUFACTURER: SHERWIN WILLIAMS COLOR: STARDEW SW9138 APPLICATION: ACCENT PT-5 MANUFACTURER: SHERWIN WILLIAMS COLOR: TRICORN BLACK SW6258 APPLICATION:HOLLOW METAL FRAMES AND DOORS -U.N.O., OTS AT CORRIDORS, DAYROOM AND APPARTUS BAY TRUSSES/STEEL, BEHIND WOOD PANELS AT LOBBY PLASTIC LAMINATE: PLAM -1 MANUFACTURER:WILSONART COLOR: NATURAL RECON 7996-38 FINISH: FINE VELVET FINISH APPLICATION: CASEWORK VERTICAL SURFACES CONCRETE: PC-1 SEE ARCHITECTURAL SPECIFICATIONS SC-1 SEE ARCHITECTURAL SPECIFICATIONS QUARTZ: Q-1 MANUFACTURER: CAMBRIA COLOR: WHITEHALL THICKNESS: 2CM APPLICATION: COUNTERTOPS RESILIENT FLOORING: RF-1 MANUFACTURER: KIEFER USA STYLE: MONDO SPORT IMPACT RUBBER ROLL THICKNESS: 10MM FLOOR ; 6MM BASE COLOR: DARK GREY 018 APPLICATION: FITNESS ROOM RF-2 MANUFACTURER: SHAW CONTRACT STYLE: ABIDE THICKNESS: 2.5MM SIZE: 7" X 48" COLOR: CADMIUM OAK APPLICATION: WELLNESS ROOMS / DAYROOM KITCHEN RF-3 MANUFACTURER: SHAW CONTRACT STYLE:COMMINGLE THICKNESS: 5MM SIZE: 9" X 48" COLOR: SLATE APPLICATION:CORRIDOR 200 / ADMIN WORKROOM 202 BASE: RB-1 MANUFACTURER: JOHNSONITE STYLE:4" COVE COLOR: BLACK 40 APPLICATION: FIELD BASE RB-2 MANUFACTURER: JOHNSONITE STYLE:4" COVE COLOR: WHITE W 50 APPLICATION: POLICE PRIVATE RESTROOM SS-1 MANUFACTURER: CORIAN COLOR: GLACIER ICE THICKNESS: 2CM APPLICATION: WINDOW SILLS SOLID SURFACE: STAINLESS STEEL: SST-1 MANUFACTURER:SEE ARCHITECTURAL SPECIFICATIONS APPLICATION:COUNTERTOPS AS INDICATED T-1 MANUFACTURER: KATE-LO COLLECTION:NATUREL COLOR: BEIGE GROUT: G-1 SIZE: 8" X 48" TRIM:SEE METAL TRANSITIONS INSTALL METHOD: 1/3 STAGGER APPLICATION: FLOORS, INDIVIDUAL RESTROOMS TILE: T-2 MANUFACTURER: KATE-LO COLLECTION: I COCCI COLOR: CENERE GROUT: G-2 SIZE: 12" X 24" TRIM:SEE METAL TRANSITIONS INSTALL METHOD: STRAIGHT LAY APPLICATION: FLOORS, PUBLIC RESTROOM T-3 MANUFACTURER:VIRGINIA TILE COLLECTION:WOW USA -GRADIENT COLOR:WHITE FINISH: GLOSSY GROUT: G-2 SIZE: 3" X12" TRIM:SEE METAL TRANSITIONS INSTALL METHOD: VERTICAL STACK BOND APPLICATION: SINK WALLS, RESTROOMS T-4 MANUFACTURER: KATE-LO COLLECTION:BASALTINE COLOR:WHITE GROUT: G-2 SIZE: 12" X 24" TRIM:SEE METAL TRANSITIONS INSTALL METHOD: HORIZONTAL STACK BOND APPLICATION: FIELD TILE WALLS, RESTROOMS TA-1 MANUFACTURER: SCHLUTER STYLE:KERDI-BOARD-SN PRODUCT NUMBER: KB 12 SN 305 508 A1 SIZE: 12" X 20" X 3 1/2" MOUNTING HEIGHT: 30" NOTES: TILE NICHE SAME AS ASSIGNED FOR DESIGNATED WALL APPLICATION: SHOWERS TOILET ACCESSORIES: TP-1 MANUFACTURER: SCRANTON PRODUCTS STYLE:HINY HIDERS MOUNTING STYLE:FLOOR MOUNTED COLOR: MIDNIGHT APPLICATION: PUBLIC RESTROOMS TOILET PARTITION: WD-1 MANUFACTURER: URBAN EVOLUTION SPECIES: WHITE OAK CUT: RIFT FINISH:CLEAR MATTE NOTE: APPLICATION: WOOD DOORS WOOD: WD-2 MANUFACTURER: RULON INTERNATIONAL SYSTEM: ENDURE WOODGRAIN 900 SPECIES COLOR: WHITE OAK NOTE: APPLICATION: EXTERIOR SOFFITS, SEE RCP WD-3 MANUFACTURER: RULON INTERNATIONAL SYSTEM: LINEAR OPEN SIZE:3 1/4" X 3/4" PLANK (3/4" REVEAL) SPECIES COLOR: WHITE OAK NOTE: APPLICATION: INTERIOR CEILINGS, SEE RCP WM-1 MANUFACTURER: MOHAWK GROUP STYLE:FIRST STEP II GT315 COLOR: OBSIDIAN 989 SIZE: 24" X 24" INSTALLATION: MONOLITHIC APPLICATION: VESTIBULE WALK-OFF MAT: WP MANUFACTURER: KOROSEAL STYLE: KOROGARD WALL PROTECTION SYSTEMS -S412LT COLOR: SIMPLY WHITE (TE) TEXTURE: P1 DUNE ADHESIVE:RUB STRIP 9070 HEIGHT: 12" MOUNTING HEIGHT: TOP AT 48" THICKNESS: .040" APPLICATION: POLICE CORRIDORS WALL PROTECTION: WT-1 TYPE:SINGLE SHADE SOULTION:SHEERSHADE SHADE CLOTH:WSC-1 MOUNTING: WALL MOUNTED HOUSING:NONE OPERATION: MANUAL APPLICATION: OFFICES WHERE INDICATED -SEE RCP DETAILING:RECESSED; REVEAL PROVIDED AT CEILING FOR SHADE OPERATION. NOTES:SHADE TO EXTEND BEYOND WINDOW FRAME BY TWO INCHES ON EACH SIDE TO MINIMIZE LIGHT GAP FOR ALL PUNCHED WINDOWS CONTACT:BRENDA GOLWITZER BRENDA.GOLWITZER@CONVERGELANE.COM (515) 554-4331 WINDOW TREATMENT: T-5 MANUFACTURER: VIRGINIA TILE COLLECTION:WOW USA -GRADIENT COLOR:BLACK FINISH: MATTE GROUT: G-3 SIZE: 3" X12" TRIM:SEE METAL TRANSITIONS INSTALL METHOD: VERTICAL STACK BOND APPLICATION: BREAKROOM AND DAYROOM KITCHEN TB-1 MANUFACTURER: KATE-LO COLLECTION:BASALTINE COLOR:WHITE GROUT: G-2 TRIM:SEE METAL TRANSITIONS SIZE: 6" X 24" APPLICATION: TYPICAL AT T-4 LOCATIONS PT-6 (EXT. PAINT) MANUFACTURER: SHERWIN WILLIAMS COLOR: BALANCED BEIGE SW7037 APPLICATION:EXTERIOR DOORS/LOUVERS; REFER TO DOOR SCHEDULE WSC-1 MANUFACTURER: LUTRON SOLUTION: SHEERSHADE 3% FABRIC :MERMET BASKETWEAVE E SCREEN (ES) COLOR: CHARCOAL/CHARCOAL CONTACT:BRENDA GOLWITZER BRENDA.GOLWITZER@CONVERGELANE.COM (515) 554-4331 WSC-2 MANUFACTURER:LUTRON SOLUTION: BLACKOUT FABRIC :MERMET VERONA TWILIGHT COLOR: ECLIPSE NOTE:BLACKOUT SHADE FABRIC TO HAVE WHITE SIDE FACING INTERIOR/DARK SIDE FACING EXTERIOR CONTACT:BRENDA GOLWITZER BRENDA.GOLWITZER@CONVERGELANE.COM (515) 554-4331 WSC-3 MANUFACTURER:LUTRON SOLUTION: BLACKOUT FABRIC :MERMET VERONA TWILIGHT COLOR: COORIDNATE WITH GLASS OPENING; SHADE MOUNTED IN ROOMS FACING RECEPTION DESK AREA (201, 301); FABRIC COLOR FACING RECPTION AREA/FACING GLASS CONTACT:BRENDA GOLWITZER BRENDA.GOLWITZER@CONVERGELANE.COM (515) 554-4331 WINDOW SHADE CLOTH: PT-7 (EXT. PAINT) MANUFACTURER: RAL COLOR: SIGNAL BLACK 9004 APPLICATION:EXPOSED EXTERIOR STEEL, EXTERIOR DOORS -REFER TO DOOR SCHEDULE ACP-4 MANUFACTURER: GORDON STYLE:CEL-LINE METAL PLANK ACOUSTIC SECURITY CEILING SYSTEM SIZE: 24" WIDTH PANELS EDGE TRIM: FULL PERIMETER CHANNEL GIRD: INTEGRATED SUSPENSION SYSTEM WITH HANGER ANGLE SUPPORTS COLOR: WHITE APPLICATION: AREA C ROOMS AS INDICATED WD-4 MANUFACTURER: RULON INTERNATIONAL SYSTEM: LINEAR OPEN (PANELIZED) SIZE:3 3/4" X 3/4" PLANK (1/4" REVEAL) LENGTH:SEE ELEVATIONS SPECIES COLOR: WHITE OAK NOTE:VERTICAL INSTALLATION PATTERN APPLICATION: ACCENT WALLS IN LOBBY AND BREAK ROOM WT-2 TYPE:SINGLE SHADE SOLUTION:BLACKOUT SHADE CLOTH:WSC-2 MOUNTING: WALL MOUNTED HOUSING:NONE OPERATION: MANUAL APPLICATION: BUNK ROOMS -SEE RCP DETAILING:RECESSED; REVEAL PROVIDED AT CEILING FOR SHADE OPERATION. NOTES:SHADE TO EXTEND BEYOND WINDOW FRAME BY TWO INCHES ON EACH SIDE OF OPENING WHERE POSSIBLE. INCLUDE SIDE CHANNEL/SILL ANGLE ON SURFACE OF PUNCHED WINDOW TO PROVIDE COMPLETE BLACKOUT CONDITIONS. BLACKOUT SHADE FABRIC TO HAVE WHITE SIDE FACING INTERIOR/DARK SIDE FACING EXTERIOR. CONTACT:BRENDA GOLWITZER BRENDA.GOLWITZER@CONVERGELANE.COM (515) 554-4331 WT-3 TYPE:DUAL SHADE SOULTION:SHEER AND BLACKOUT SHADE CLOTH:WSC-1 / WSC-2 MOUNTING: WALL MOUNTED HOUSING:NONE OPERATION: MANUAL APPLICATION: OFFICES WHERE INDICATED -SEE RCP DETAILING:RECESSED; REVEAL PROVIDED AT CEILING FOR DUAL SHADE OPERATION. NOTES:SHEER SHADE AND BLACKOUT SHADE TO EXTEND BEYOND WINDOW FRAME BY TWO INCHES ON EACH SIDE TO MINIMIZE LIGHT GAP. BLACKOUT SHADE FABRIC TO HAVE WHITE SIDE FACING INTERIOR/DARK SIDE FACING EXTERIOR. CONTACT:BRENDA GOLWITZER BRENDA.GOLWITZER@CONVERGELANE.COM (515) 554-4331 WT-4 TYPE:SINGLE SHADE SOLUTION:BLACKOUT SHADE CLOTH:WSC-2 MOUNTING: FRAME MOUNTED HOUSING:NONE OPERATION: MANUAL APPLICATION: CONF. 391 -SEE RCP DETAILING:MOUNTED IN HM SIDELITE. NOTES:BLACKOUT SHADE FABRIC TO HAVE WHITE SIDE FACING INTERIOR/DARK SIDE FACING GLASS CONTACT:BRENDA GOLWITZER BRENDA.GOLWITZER@CONVERGELANE.COM (515) 554-4331 WT-5 TYPE:SINGLE SHADE SHADE CLOTH:WSC-1 SOULTION:SHEERSHADE MOUNTING: CEILING MOUNTED HOUSING:METAL POCKET WITH FLAP/HANGER OPERATION: MOTORIZED APPLICATION: SOUTH CLERESTORY WINDOWS IN LOBBY AND FITNESS -SEE RCP; COUPLE/BAND SHADES TO MINIMIZE MOTOR COUNT AND POWER RUNS, SEAMS TO ALIGN WITH CL OF WINDOW MULLIONS. DETAILING:RECESSED, REVEAL PROVIDED AT CEILING FOR SHADE OPERATION. CONTROLS:PROVIDE TWO KEYPAD CONTROLS (ONE AT EACH RECEPTION AREA TO CONTROL SHADES). COORDINATE LOCATION AND INSTALLATION WITH ELECTRICAL CONTRACTOR / ARCHITECT CONTACT:BRENDA GOLWITZER BRENDA.GOLWITZER@CONVERGELANE.COM (515) 554-4331 WT-6 TYPE:SINGLE SHADE SOULTION:BLACKOUT SHADE CLOTH:WSC-2 MOUNTING: CEILING MOUNTED HOUSING:METAL POCKET WITH FLAP/HANGER OPERATION: MOTORIZED APPLICATION: NORTH CLERESTORY WINDOWS IN TRAINING ROOM 102 -SEE RCP; COUPLE/BAND SHADES TO MINIMIZE MOTOR COUNT AND POWER RUNS, SEAMS TO ALIGN WITH CL OF WINDOW MULLIONS. DETAILING: RECESSED; REVEAL PROVIDED AT CEILING FOR SHADE OPERATION. CONTROLS: PROVIDE TWO KEYPAD CONTROLS. COORDINATE LOCATION AND INSTALLATION WITH ELECTRICAL CONTRACTOR / ARCHITECT CONTACT:BRENDA GOLWITZER BRENDA.GOLWITZER@CONVERGELANE.COM (515) 554-4331 WT-7 TYPE:SINGLE SHADE SOLUTION:BLACKOUT SHADE CLOTH:WSC-3 MOUNTING: CEILING MOUNTED HOUSING:METAL POCKET WITH FLAP/HANGER, GYPSUM BOARD CEILING OPERATION: MANUAL APPLICATION: TWO RECEPTION DESKS OFF LOBBY -SEE RCP DETAILING:COORDINATE WITH GLASS OPENING; FABRIC COLOR FACING LOBBY AREA/FACING GLASS CONTACT:BRENDA GOLWITZER BRENDA.GOLWITZER@CONVERGELANE.COM (515) 554-4331 ACP-5 MANUFACTURER: ARMSTRONG STYLE:CLEAN ROOM FL SIZE: 24" X 24" EDGE TRIM: FULL PERIMETER CHANNEL GIRD: 15/16" SUPRAFINE XL COLOR: WHITE APPLICATION: KITCHENETTE, EVIDENCE ROOMS - REFER TO RCP Q-2 MANUFACTURER: BRADLEY COLOR: MESA WHITE -MATTE APPLICATION: SINK BASIN AT BRADLEY VERGE SINKS MB-1 SIZE:48"W X 48"H COLOR:WHITE SEE SPECIFICATION FOR PRODUCT INFORMATION VISUAL DISPLAY SURFACE: MB-2 SIZE:72"W X 48"H COLOR:WHITE SEE SPECIFICATION FOR PRODUCT INFORMATION PLAM -2 MANUFACTURER:WILSONART COLOR: SILVER MESH 13056-38 FINISH: FINE VELVET FINISH APPLICATION: PLAM COUNTERTOPS CAPRET CONCRETE SCHLUTER RENO-U PORCELAIN TILE SCHLUTER JOLLY -BRUSHED ANODIZED ALUMINUM 5/8" GYPSUM WALLBOARD RESILIENT FLOORING SCHLUTER RENO-U CONCRETE TILE SCHLUTER RENO-U CONCRETE GENERAL NOTES 1. REFER TO FINISH PLANS, REFLECTED CEILING PLANS, AND ELEVATIONS FOR LOCATION AND EXTENT OF FINISHES. 2. PAINT ALL INTERIOR MISCELLANEOUS METAL GRILLES, LOUVERS ACCESS PANELS, PIPES AND CONDUIT EXPOSED TO VIEW TO MATCH THE WALLS IN WHICH THEY OCCUR UNLESS OTHERWISE NOTED. 3. ALL EXPOSED DRYWALL TO RECEIVE PAINT UNLESS NOTED OTHERWISE. 4. PAINT ALL REVEALS TO MATCH THE WALLS IN WHICH THEY OCCUR. 5. PAINT ALL LIGHT FIXTURE TRIMS AND FLANGES OF LINEAR DIFFUSERS TO MATCH THE COLOR TO THE CEILING IN WHICH THEY OCCUR. 6. PAINT ALL EXPOSED SPEAKERS WITH A PAINT THAT WILL NOT DEGRADE THEIR ACOUSTICAL PERFORMANCE IN A COLOR TO MATCH THE WALL OR CEILING IN WHICH THEY OCCUR. 7. ALL PAINTED HOLLOW METAL DOORS AND FRAMES TO BE PAINTED TO MATCH THE COLOR OF THE WALL IN WHICH THEY OCCUR U.N.O 8. PAINT HOLLOW METAL DOORS AND FRAMES EPT-1 9. REFER TO ROOM FINISH SPECIFICATION FOR CARPET PATTERN AND DIRECTION & FOR ROOM FINISH SPECIFICATIONS AND ADDITIONAL INFORMATION 10. ALIGN CARPET TILE BETWEEN ROOM TRANSITIONS 11. ALL FLOORING MATERIAL TRANSITIONS, TERMINATION AND SEAM LOCATIONS ARE TO BE CENTERED UNDER DOOR LEAFS IN CLOSED POSITION U.N.O. 12. EXTEND FLOORING INTO TOE SPACES, DOOR REVEALS, CLOSETS AND SIMILAR OPENINGS U.N.O. 13. PROVIDE FLOORING TRANSITION STRIPS AT FLOOR MATERIAL CHANGES. COORDINATE FLOORING TRANSITION MATERIAL, PROFILE, AND COLOR WITH ARCHITECT PRIOR TO INSTALLATION. 14. ALL FLOORING MATERIAL TRANSITIONS, TERMINATION AND SEAM LOCATIONS ARE TO BE CENTERED UNDER DOOR LEAFS IN CLOSED POSITION UNO 15. REFER TO SHEET A001 FOR TYPICAL MOUNTING HEIGHTS. 16. POWER AND DATA LOCATIONS ARE TO BE COORDINATED IN THE FIELD WITH FINAL FURNISHING PLANS PRIOR TO INSTALLATION OF BOXES, FITTINGS, AND RACEWAYS. 17. PAINT FINISHES AS FOLLOWS UNO: SEMI GLOSS ON ALL BLOCK WALLS, EGGSHELL ON ALL GYP BOARD WALLS, SEMI GLOSS FOR ALL METAL AND TRIM, EPOXY GLOSS AT ALL RESTROOM, LOCKER ROOMS, SHOWER WALLS AND CEILINGS, FLAT ON ALL OTHER CEILINGS. 18. COORDINATE LOCATION OF ALL FLOOR DRAINS WITH MECHANICAL DRAWINGS. 19. REFER TO RCP FOR WINDOW SHADE DETAILS. 20. RB IS INSTALLED ON CMU AND GYP BOARD SURFACES ONLY DO NOT INSTALL RB ON TILE . 21. ALL EXPOSED COLUMNS AND PIPES ARE TO BE PAINTED. COORDINATE WITH ARCHITECT UNO 22. ALL EXPOSED ENDS OF CASEWORK TO HAVE INTEGRATED FINISHED END PANELS TO MATCH ADJACENT CABINETRY. 23. ALL CASEWORK HEIGHTS THAT ARE NOTED AT 34" HEIGHT INCLUDES THE TOTAL HEIGHT OF BOTH THE COUNTERTOP AND DROP IN SINK. 34" MAXIMUM HEIGHT SHALL BE TO TOP OF DROP-IN SINK SURFACE FOR ADA COMPLIANCE. 24. ALIGN GROUT JOINT WITH BOTTOM OF LIGHT FIXTURE. 25. SCHLUTER EDGE TRIM TYP. AT ALL OUTSIDE CORNERS. JOINTS TO OCCUR AT UPPER MOST CONTINUOUS GROUT LINE 26. START FULL WALL TILE AS SHOWN 27. SCHLUTER AT TOP OF TILE TO TRANSITION TO GYPSUM WALL BOARD 28. CENTER FIXTURE ON GROUT JOINT 29. CENTER TILE AT DOORWAY 30. ALIGN BOTTOM OF HAND SOAP WITH BOTTOM OF MIRROR 31. ALIGN BOTTOM OF FIXTURES 32. CENTER WALL TILE JOINT ON CENTER OF WALL AS SHOWN 33. CENTER FLOOR TILE GROUT JOINT AS SHOWN 34. CENTER FLOOR TILE GROUT JOINT ON CENTER OF WALL 35. CENTER FULL WALL TILE ON CENTER OF WALL 36. ALIGN ALL WALL TILE GROUT JOINTS WITH FLOOR TILE GROUT JOINTS 37. CENTER FULL FLOOR TILE ON CENTER OF WALL 38. START FULL FLOOR TILE AS SHOWN 39. FRP TO 4'-0" A.F.F. W/ PT. ABOVE AT MOP SINK - REFER TO INTERIOR ELEVATIONS. PROVIDE PERIMETER TRIM AS NECESSARY 40. CUSTOM FILM AT INTERIOR GLASS - REFER TO FINISH FLOOR PLAN FOR LOCATIONS 41. CORNER GUARDS TO BE FULL HEIGHT 10' A.F.F. AT ALL PUBLIC CORRIDOR CORNERS THROUGHOUT THE BUILDING STANDARD ABBREVIATIONS ACB ACP AWP CPT CG FRP FILM EPT G MT PT PLAM PC Q RF RB SC SS T TA TB TP WC WD WM WP WT ACOUSTIC CEILING BAFFLES ACOUSTIC CEILING PANEL ACOUSTIC WALL PANEL CARPET CORNER GUARD FIBERGLASS REINFORCEMENT PANEL FILM EPOXY PAINT GROUT METAL TRANSITIONS PAINT PLASTIC LAMINATE POLISHED CONCRETE QUARTZ RESILIENT FLOORING RESILIENT BASE SEALED CONCRETE SOLID SURFACE TILE TOILET ACCESSORIES TILE BASE TOILET PARTITION WALL COVERING WOOD WALK OFF MAT WALL PROTECTION WINDOW TREATMENT ROOM FINISH SCHEDULE REMARKS 1. PT-5 AT OTS AND WALLS 10' AND ABOVE 2. RF-1 BASE TO BE 12" H - FINISH PRODUCT WITH MT-3 3. MULTIPLE FLOOR FINISHES - REFER TO FINISH FLOOR PLAN LAYOUT 4. MULTIPLE CEILING MATERIALS - REFER TO REFLECTED CEILING PLAN 5. MULTIPLE WALL FINISHES - REFER TO FINISH PLAN AND ELEVATIONS RF-1 SCHLUTER JOLLY -BRUSHED ANODIZED ALUMINUM 5/8" GYPSUM WALLBOARD 12 " RF-1 CONRETE A 19181716151413121110987654 B C D E F G H J K L M N P Q PR I N T E D : R S T U 20 21 22 23 24 25 Sheet Name Key Plan 321 19181716151413121110987654 20 21 22 23 24 25321 Sheet Number Sheet Issue Date OPN Project No. 26 26 27 27 28 28 29 29 V W X Y Owner All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc. shall retain all common law, statutory and other reserved rights, including the copyright thereto. © 2022 OPN Architects, Inc. 100 Court Ave., Suite 100 Des Moines, IA 50309 P: 515-309-0722 www.opnarchitects.com RYAN COMPANIES 111 E GRAND AVENUE, SUITE 200 DES MOINES, IA 50309 P. 515-309-8500 Project Construction Manager FOTH 8191 BIRCHWOOD COURT, SUITE L JOHNSTON, IA 50131 P. 515-254-1393 Civil Engineer RAKER RHODES ENGINEERING 4717 GRAND AVENUE DES MOINES, IA 50313 P. 515-277-0275 Structural Engineer MORRISSEY ENGINEERING 4940 NORTH 118TH STREET OMAHA, NE 68164 P. 402-491-4144 MEPT Engineer CONFLUENCE 525 17TH STREET DES MOINES, IA 50309 P. 515-288-4875 Landscape Architect A B C 6/ 1 0 / 2 0 2 4 1 : 5 3 : 3 4 P M A600 INTERIOR FINISH SCHEDULE 21841001 CONSTRUCTION SET 11/21/2023 WAUKEE PUBLIC SAFETY BUILDING 815 NW 20th STREET WAUKEE, IA 50263 CITY OF WAUKEE 230 W. HICKMAN ROAD WAUKEE, IA 50263 ROOM FINISH SCHEDULE NUMBER ROOM NAME FLOOR WALL CEILING MATERIAL CEILING FINISH NOTESFINISH BASE NORTH EAST SOUTH WEST LEVEL 1 000-E COVERED PATIO - - - - - - - - - 000-W PUBLIC PLAZA - - - - - - - - - 100 VESTIBULE WM - - - - - GYP PT-1 - 101 LOBBY PC - WD-4 / PT-1 / PT-5 WD-4 / PT-1 / PT-5 WD-2 / PT-1 / PT-5 PT-1 / PT-5 WD-3 - 5 102 TRAINING ROOM CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 / PT-4 WD-3 - 5 103 VENDING PC RB-1 PT-1 PT-1 PT-1 WD-4 ACP-1 - 5 104 KITCHENETTE PC RB-1 EPT-1 EPT-1 EPT-1 EPT-1 ACP-1 - 110 CORRIDOR PC - WD-2 / PT-5 WD-2 / PT-5 WD-2 / PT-5 WD-2 / PT-5 GYP PT-1 5 111 MENS RESTROOM T-2 TB-1 EPT-1 T-4 / EPT-1 EPT-1 T-4 / EPT-1 GYP EPT-1 5 112 FAMILY RESTROOM T-2 TB-1 EPT-1 EPT-1 EPT-1 T-4 GYP EPT-1 5 113 WOMENS RESTROOM T-2 TB-1 EPT-1 T-4 / EPT-1 EPT-1 T-4 / EPT-1 GYP EPT-1 5 114 FAMILY INTERVIEW / F.PRINT CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 115 INTERVIEW CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 116 INTERVIEW CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 121 FITNESS CENTER RF-1 RF-1 PT-1 PT-1 PT-1 PT-1 WD-3 - 2 122 FITNESS STORAGE SC RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 123 TRAINING STORAGE SC RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 124 MEZZANINE ACCESS SC RB-1 PT-1 PT-1 PT-1 PT-1 OTS PT-1 - 125 UNISEX RR T-1 T-1 EPT-1 EPT-1 EPT-1 T-4 GYP EPT-1 5 126 SAUNA T-1 T-1 EPT-1 EPT-1 EPT-1 EPT-1 GYP EPT-1 - 200 CORRIDOR RF-3 RB-1 - PT-1 / PT-5 PT-1 PT-1 / PT-5 ACB-2 PT-5 1 201 ADMIN / RECEPTION CPT-1 RB-1 PT-4 - PT-1 PT-1 ACP-1 - 5 202 ADMIN WORKROOM RF-3 RB-1 PT-1 PT-1 PT-1 - ACP-1 - - 203 OFFICE - FIRE PREV. CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 204 OFFICE - INSPECTOR CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 205 OFFICE - MARSHAL CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 206 PLAN ROOM CPT-2 RB-1 PT-1 PT-4 PT-1 PT-1 ACP-1 - 5 207 OFFICE - CHIEF CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 208 OFFICE - FLEX CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 210 CORRIDOR SC RB-1 - PT-1 / PT-5 PT-1 PT-1 / PT-5 GYP / ACB-2 PT-5 1 211 FIRE TRAINING CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 / WD-3 - 4 212 STORAGE SC RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 213 DAYROOM CPT-2 / RF-2 RB-1 PT-1 PT-1 - PT-1 / PT-4 GYP / WD-3 / ACB-1 - 3, 4, 5 214 KITCHEN RF-2 RB-1 - PT-1 T-5 / PT-1 T-5 / PT-1 GYP / WD-3 PT-1 4, 5 215 OFFICE - LT CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 220 CORRIDOR SC RB-1 PT-1 / PT-5 - PT-1 / PT-5 - ACB-2 / GYP PT-5 1, 4 221 FIRE ENTRY SC RB-1 PT-1 PT-1 PT-1 - GYP PT-1 222 CONFERENCE CPT-1 RB-1 PT-1 PT-4 PT-1 PT-1 ACP-1 - 5 223 STORAGE SC RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 224 LIBRARY CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 226 STAIR B SC RB-1 PT-1 PT-1 PT-1 - GYP / OTS PT-1 4 230 CORRIDOR SC RB-1 PT-1 PT-1 / PT-5 - PT-1 / PT-5 ACB-2 PT-5 1 231 OFFICE - DPT. CHIEF CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 232 RESTROOM T-1 T-3 T-3 T-3 T-3 T-3 GYP EPT-1 - 233 OFFICE - EMS DPT. CHIEF CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 234 OFFICE - DPT. CHIEF TRAINING CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 235 OFFICE - FLEX CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 236 ELECTRICAL SC RB-1 EPT-2 EPT-2 EPT-2 EPT-2 OTS EPT-1 - 240 CORRIDOR SC RB-1 PT-1 PT-1 / PT-5 - PT-1 / PT-5 ACB-2 PT-5 1 241 LOCKER ROOM SC RB-1 EPT-1 EPT-1 EPT-1 EPT-1 GYP EPT-1 - 242 RR / SHWR T-1 T-3 T-3 T-3 T-3 T-3 GYP EPT-1 - 243 RR / SHWR T-1 T-3 T-3 T-3 T-3 T-3 GYP EPT-1 - 244 WELLNESS RF-2 RB-1 EPT-1 EPT-1 EPT-1 EPT-4 GYP EPT-1 5 245 RR / SHWR T-1 T-3 T-3 T-3 T-3 T-3 GYP EPT-1 - 246 RR / SHWR T-1 T-3 T-3 T-3 T-3 T-3 GYP EPT-1 - 247 MEDIUM DECON SC RB-1 EPT-2 EPT-2 EPT-2 EPT-2 ACP-5 - - 248 RR / SHWR T-1 T-3 T-3 T-3 T-3 T-3 GYP EPT-1 - 250 CORRIDOR CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 GYP PT-1 - 250A BUNK CPT-2 RB-1 PT-1 PT-1 PT-1 PT-4 ACP-1 - 5 250B BUNK CPT-2 RB-1 PT-1 PT-1 PT-1 PT-4 ACP-1 - 5 250C BUNK CPT-2 RB-1 PT-1 PT-1 PT-1 PT-4 ACP-1 - 5 250D BUNK CPT-2 RB-1 PT-1 PT-1 PT-1 PT-4 ACP-1 - 5 250E BUNK CPT-2 RB-1 PT-1 PT-1 PT-4 PT-1 ACP-1 - 5 250F BUNK CPT-2 RB-1 PT-1 PT-1 PT-4 PT-1 ACP-1 - 5 250G BUNK CPT-2 RB-1 PT-1 PT-1 PT-4 PT-1 ACP-1 - 5 250H BUNK CPT-2 RB-1 PT-1 PT-1 PT-4 PT-1 ACP-1 - 5 250J BUNK CPT-2 RB-1 PT-1 PT-1 PT-4 PT-1 ACP-1 - 5 250K BUNK CPT-2 RB-1 PT-1 PT-1 PT-4 PT-1 ACP-1 - 5 251 STORAGE CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - 5 260 APPARATUS BAY SC - EPT-2 EPT-5 EPT-2 EPT-5 OTS FACTORY FINISH 5 261 FIRE SERVICE ENTRANCE SC RB-1 EPT-2 EPT-2 EPT-2 EPT-2 OTS EPT-1 - 262 EMS STORAGE SC RB-1 EPT-2 EPT-2 EPT-2 EPT-2 OTS EPT-1 - 264 SHOP SC - EPT-2 - EPT-2 EPT-2 OTS EPT-1 - 265 EQUIP. SC - EPT-2 EPT-2 EPT-2 - OTS EPT-1 - 266 TURNOUT ROOM SC - EPT-2 EPT-2 EPT-2 EPT-2 OTS EPT-1 - 267 GROSS DECON SC - EPT-2 EPT-2 EPT-2 EPT-2 OTS EPT-1 - 268 EAST ENTRY SC - EPT-2 EPT-2 EPT-2 EPT-2 OTS EPT-1 - 269 STAIR A SC - EPT-2 EPT-2 - EPT-2 OTS EPT-1 - 300 CORRIDOR SC RB-1 WP / PT-1 / PT-5 WP / PT-1 / PT-5 - W P / PT-1 / PT-5 ACB-2 PT-5 1, 5 301 RECORDS TECHS CPT-1 RB-1 PT-1 PT-1 PT-4 PT-1 ACP-1 - 5 302 PRINT / COPY CPT-2 RB-1 PT-4 PT-1 PT-1 PT-1 ACP-1 - 5 303 OFFICE CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 304 OFFICE CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 305 OFFICE CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 306 SECURE FILES SC RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 307 EQUIPMENT STORAGE SC RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 310 CORRIDOR SC RB-1 WP / PT-1 / PT-5 WP / PT-1 / PT-5 - W P / PT-1 / PT-5 ACB-2 PT-5 1, 5 311 WELLNESS RF-2 RB-1 EPT-1 EPT-1 EPT-1 EPT-4 ACP-1 - 5 312 CUSTODIAL SC RB-1 EPT-1 EPT-1 EPT-1 EPT-1 OTS EPT-1 - 313 STORAGE SC RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 320 CORRIDOR SC RB-1 WP / PT-1 / PT-5 / WD-4 - WP / PT-1 / PT-5 - ACB-2 / GYP PT-1 / PT-5 1, 4, 5 ROOM FINISH SCHEDULE NUMBER ROOM NAME FLOOR WALL CEILING MATERIAL CEILING FINISH NOTESFINISH BASE NORTH EAST SOUTH WEST 321 WOMENS LOCKER SC RB-1 EPT-1 EPT-1 EPT-1 EPT-1 OTS / GYP EPT-1 4 321A RR / SHWR T-1 T-1 / T-3 EPT-1 T-3 EPT-1 EPT-1 GYP EPT-1 5 321B RR / SHWR T-1 T-1 / T-3 EPT-1 EPT-1 EPT-1 T-3 GYP EPT-1 5 322 MENS LOCKER SC RB-1 EPT-1 EPT-1 EPT-1 EPT-1 OTS / GYP EPT-1 4 322A RR / SHWR T-1 T-1 / T-3 EPT-1 T-3 EPT-1 EPT-1 GYP EPT-1 5 322B RR / SHWR T-1 T-1 / T-3 EPT-1 EPT-1 EPT-1 T-3 GYP EPT-1 5 322C RR / SHWR T-1 T-1 / T-3 EPT-1 T-3 EPT-1 EPT-1 GYP EPT-1 5 323 UNISEX RR T-1 T-1 / T-3 EPT-1 EPT-1 T-3 EPT-1 GYP EPT-1 5 324 UNISEX RR/SHOWER T-1 T-1 / T-3 T-3 T-3 T-3 T-3 GYP EPT-1 5 325 UNISEX RR T-1 T-1 / T-3 EPT-1 EPT-1 T-3 EPT-1 GYP EPT-1 5 326 BREAK ROOM SC RB-1 PT-1 T-5 / PT-1 T-5 / PT-1 PT-4 / PT-1 WD-3 / ACP-2 / GYP PT-1 4, 5 327 SGT. BULLPEN CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 / GYP PT-1 - 328 REPORTS CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 / GYP PT-1 - 329 ROLL CALL CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 330 CORRIDOR SC RB-1 - WP / PT-1 / PT-5 - WP / PT-1 / PT-5 ACB-2 PT-5 1, 5 331 COMMAND CONFERENCE CPT-1 RB-1 PT-1 PT-1 / PT-4 PT-1 PT-1 WD-3 / ACP-1 / GYP PT-1 4, 5 332 POLICE TRAINING CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 / PT-4 W D-3 / ACP-1 / GYP PT-1 4, 5 333 TRAINING STORAGE CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 340 CORRIDOR SC RB-1 - WP / PT-1 / PT-5 - WP / PT-1 / PT-5 ACB-2 PT-5 1, 5 341 MECH / ELEC. SC RB-1 EPT-1 EPT-1 EPT-1 EPT-1 OTS EPT-1 - 342 IDF SC RB-1 PT-1 PT-1 PT-1 PT-1 OTS PT-1 - 350 CORRIDOR SC RB-1 WP / PT-1 WP / PT-1 WP / PT-1 WP / PT-1 GYP PT-1 5 353 DEPT. STORAGE SC RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 354 QUARTERMASTER SC RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 360 CORRIDOR SC RB-1 - WP / PT-1 / PT-5 - WP / PT-1 / PT-5 ACB-2 PT-5 1, 5 361 POLICE ENTRY SC RB-1 - WP / PT-1 - WP / PT-1 ACB-2 / GYP PT-5 1, 5 362 PATROL STORAGE SC RB-1 - WP / PT-1 - PT-1 / PT-4 ACP-1 -5 363 BAG & TAG SC RB-1 - PT-1 / PT-4 - WP / PT-1 ACP-1 - - 364 EVIDENCE PROCESSING SC RB-1 EPT-1 EPT-1 EPT-1 EPT-1 ACP-5 - - 365 BULK EVIDENCE SC RB-1 EPT-1 EPT-1 EPT-1 EPT-1 ACP-5 - - 366 DRYING ROOM SC RB-1 EPT-1 EPT-1 EPT-1 EPT-1 ACP-5 - - 367 HIGH VALUE EVIDENCE SC RB-1 EPT-1 EPT-1 EPT-1 EPT-1 ACP-5 - - 368 F.A.T.S. SC RB-1 PT-5 PT-5 PT-5 PT-5 ACP-3 - - 370 CORRIDOR SC RB-1 WP / PT-1 / PT-5 - WP / PT-1 / PT-5 -ACB-2 PT-1 / PT-5 1, 5 371 CHIEF CONFERENCE CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 372 OFFICE - ASST. CHIEF CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 373 OFFICE - CHIEF CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 374 OFFICE - ASST. CHIEF CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 375 CORRIDOR SC RB-1 - WP / PT-1 / PT-5 - WP / PT-1 / PT-5 ACB-2 / GYP PT-1 / PT-5 1, 4, 5 380 CORRIDOR SC RB-1 - WP / PT-1 PT-5 - WP / PT-1 / PT-5 ACB-2 / GYP PT-1 / PT-5 1, 4, 5 381 OFFICE CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 382 OFFICE CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 383 OFFICE CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 384 OFFICE CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 385 OFFICE CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 386 OFFICE CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 390 OPEN OFFICE CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 391 INVEST. CONFERENCE CPT-1 RB-1 PT-1 PT-1 / PT-4 PT-1 PT-1 WD-3 / ACP-1 / GYP PT-1 4, 5 392 COMPUTER FORENSICS SC RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 393 SECURED STORAGE SC RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 394 OFFICE - SGT CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 395 OFFICE - FUTURE CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 396 OFFICE - FUTURE CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 397 EVIDENCE TECH CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 398 EVIDENCE CUSTODIAN CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACP-1 - - 399 RESTROOM T-1 T-1 / T-3 T-3 EPT-1 EPT-1 EPT-1 GYP EPT-1 5 400 CORRIDOR SC RB-1 EPT-2 EPT-2 EPT-2 EPT-2 OTS EPT-1 - 401 OPEN OFFICE CPT-2 RB-1 EPT-1 EPT-1 EPT-1 EPT-1 ACP-1 - - 403 MECHANICAL SC - EPT-2 EPT-2 EPT-2 EPT-2 OTS EPT-1 - 403A WATER ENTRY SC RB-1 EPT-2 EPT-2 EPT-2 EPT-2 OTS EPT-1 - 404 ARMORY SC RB-1 EPT-2 EPT-2 EPT-2 EPT-2 ACP-1 - - 406 LARGE ARTICLES SC RB-1 EPT-2 EPT-2 EPT-2 EPT-2 OTS EPT-1 - 407 PATROL STORAGE SC RB-1 EPT-2 EPT-2 EPT-2 EPT-2 OTS EPT-1 - 408 IDF SC RB-1 EPT-1 EPT-1 EPT-1 EPT-1 OTS EPT-1 - 409 ELECTRICAL SC - EPT-2 EPT-2 EPT-2 EPT-2 OTS EPT-1 - 410 FOUND ARTICLES SC RB-1 EPT-2 EPT-2 EPT-2 EPT-2 OTS EPT-1 - 420 INDOOR GARAGE SC - EPT-2 EPT-2 EPT-2 EPT-2 OTS EPT-1 - 421 VEHICLE EVIDENCE SC - EPT-2 EPT-2 EPT-2 EPT-2 OTS EPT-1 - 422 WASH BAY SC - EPT-2 EPT-2 EPT-2 - OTS EPT-1 - 423 TRAFFIC STORAGE SC - EPT-2 EPT-2 EPT-2 EPT-2 OTS EPT-1 - 430 PROCESSING SC RB-1 EPT-1 EPT-1 EPT-1 EPT-1 ACP-4 - - 431 VESTIBULE SC RB-1 EPT-1 EPT-1 EPT-1 EPT-1 ACP-4 - - 432 INTERVIEW SC RB-1 EPT-1 EPT-1 EPT-1 EPT-1 ACP-4 - - 433 RESTROOM SC RB-1 EPT-1 EPT-1 EPT-1 EPT-1 ACP-4 - - 434 INTERVIEW SC RB-1 EPT-1 EPT-1 EPT-1 EPT-1 ACP-4 - - 435 DRE / OWI SC RB-1 EPT-1 EPT-1 EPT-1 EPT-1 ACP-4 - - 450 SHELL SPACE SC - - - - - OTS - - MEZZANINE 218 MECHANICAL SC RB-1 EPT-2 EPT-2 EPT-2 EPT-2 OTS EPT-1 270 STORAGE MEZZANINE SC - EPT-2 - EPT-2 EPT-2 OTS EPT-1 - 271 STORAGE MEZZANINE SC - EPT-2 EPT-2 EPT-2 EPT-2 OTS EPT-1 - 272 MECHANICAL SC - EPT-2 EPT-2 EPT-2 EPT-2 OTS EPT-1 - 273 SECURE STORAGE SC - EPT-2 EPT-2 EPT-2 EPT-2 OTS EPT-1 - 280 MECHANICAL MEZZANINE SC RB-1 EPT-2 EPT-2 EPT-2 EPT-2 OTS EPT-1 - 281 IT SC RB-1 EPT-1 EPT-1 EPT-1 EPT-1 OTS EPT-1 - 12" = 1'-0"A8 CARPET TO CONCRETE TRANSITION DETAIL 12" = 1'-0"A20 TILE TO GYPSUM TRANSITION DETAIL 12" = 1'-0"A12 RESILIENT FLOORING TO CONCRETE TRANSITION DETAIL 12" = 1'-0"A16 TILE TO CONCRETE TRANSITION DETAIL 3" = 1'-0"A24 RESILIENT FLOOR WALL BASE Revision Description Date ADD 02 Addendum 10/31/23 ADD 03 Addendum 11/14/23 ASI 07 ASI 4/29/2024 PR 05 PR - REV. 1 4/30/2024 ADD 02 ADD 03 ADD 03 ASI 07 PR 05 Waukee Public Safety - Change Request Summary 6/11/2024 Ryan Companies US, Inc. Change Request Subcontractor Comments Cost Change 20.0 DDVI Added PLAM counter, grommets, and lower cabinets in room 392. Clarified elevation at room 302, adding quartz counter and lower cabinets. Removed N/S shelf with closet rod in room 354.$17,216.30 20.1 Jordison Construction No response $0.00 20.2 Enterprise Precast No response $0.00 20.3 TSF Structures No response $0.00 20.4 Northwest Steel No response $0.00 20.5 Forman Ford No response $0.00 20.6 Academy Roofing No response $0.00 20.7 Ford Metro No response $0.00 20.8 Skold Door No response $0.00 20.9 Hilsabeck Schacht No response $0.00 20.10 Elite Fire Sprinkler No response $0.00 20.11 Kruck Plumbing and Heating No response $0.00 20.12 Van Maanen No response $0.00 20.13 TriCity Electric No response $0.00 20.14 Wenthold No response $0.00 20.15 Absolute No response $0.00 20.16 Jordison Construction No response $0.00 20.17 Alpha Landscapes No response $0.00 $17,216.30 Builders Risk (.23% Cost of Work (Estimated)) Excluded per City $0.00 CMa Fee on Cost of Work (3.25%)$559.53 CMa Project Manager Time $0.00 CMa Project Superintendent Time $0.00 $17,775.83 Change Request 020 Summary: PR-05 Casework revisions. Change Request 020 Subtotal Change Request 020 Cost Change Total w PROPOSAL REQUEST – PR NO. 07 Please submit an itemized proposal for changes in the Contract Sum and Contract Time for proposed modifications to the Contract Documents described herein. This is not a Change Order, a Construction Change Directive or a direction to proceed with the w ork described in the proposed modifications. Proceeding with the Work prior to authorization indicates your acknowledgement that there will be no change in the Contract Sum or Contract Time. Description: Revisions to door hardware based on shop drawing review and owner feedback. 1. Specification 08 71 00 • Opening 307 moved to hardware set 19.0. • Opening 247B moved to new hardware set 48.1. • Openings 230 and 240 stayed in set 13.0 with the set updated to add an exit device. 2. Sheet A800 – DOOR SCHEDULE • Opening 307 – added schedule note 1 for card reader to match telecom drawings and updated hardware set to 19.0 • Opening 247B – updated hardware set to 48.1 OPN Architects, Inc. Date: 05/02/2024 Project: Waukee Public Safety Facility Project number: 21841001 Client: City of Waukee Construction Manager: Ryan Companies CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 1 SECTION 08 71 00 DOOR HARDWARE PART 1 - GENERAL 1.1 SUMMARY A. This Section includes commercial door hardware for the following: 1. Swinging doors. 2. Sliding doors. 3. Other doors to the extent indicated. B. Door hardware includes, but is not necessarily limited to, the following: 1. Mechanical door hardware. 2. Electromechanical door hardware. 3. Automatic operators. 4. Cylinders specified for doors in other sections. C. Related Sections: 1. Division 08 Section “Hollow Metal Doors and Frames”. 2. Division 08 Section “Flush Wood Doors”. 3. Division 08 Section “Aluminum-Framed Entrances and Storefronts”. 4. Division 08 Section “All-Glass Entrances”. 5. Division 28 Section “Access Control Hardware Devices”. D. Codes and References: Comply with the version year adopted by the Authority Having Jurisdiction. 1. ANSI A117.1 - Accessible and Usable Buildings and Facilities. 2. ICC 500-2014/2020, ICC/NSSA Standard for the Design and Construction of Storm Shelters. 3. ICC/IBC - International Building Code. 4. NFPA 70 - National Electrical Code. 5. NFPA 80 - Fire Doors and Windows. 6. NFPA 101 - Life Safety Code. 7. NFPA 105 - Installation of Smoke Door Assemblies. 8. State Building Codes, Local Amendments. E. Standards: All hardware specified herein shall comply with the following industry standards as applicable. Any undated reference to a standard shall be interpreted as referring to the latest edition of that standard: 1. ANSI/BHMA Certified Product Standards - A156 Series. 2. UL10C - Positive Pressure Fire Tests of Door Assemblies. 3. ANSI/UL 294 - Access Control System Units. 4. UL 305 - Panic Hardware. 5. ANSI/UL 437- Key Locks. 1.2 SUBMITTALS A. Product Data: Manufacturer's product data sheets including installation details, material descriptions, dimensions of individual components and profiles, operational descriptions and finishes. B. Door Hardware Schedule: Prepared by or under the supervision of supplier, detailing, fabrication and assembly of door hardware, as well as procedures and diagrams. Coordinate the final Door Hardware Schedule with doors, frames, and related work to ensure proper size, thickness, hand, function, and finish of door hardware. 1. Format: Comply with scheduling sequence and vertical format in DHI's "Sequence and Format for the Hardware Schedule." 2. Organization: Organize the Door Hardware Schedule into door hardware sets indicating complete designations of every item required for each door or opening. Organize door CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 2 hardware sets in same order as in the Door Hardware Sets at the end of Part 3. Submittals that do not follow the same format and order as the Door Hardware Sets will be rejected and subject to resubmission. 3. Content: Include the following information: a. Type, style, function, size, label, hand, and finish of each door hardware item. b. Manufacturer of each item. c. Fastenings and other pertinent information. d. Location of door hardware set, cross-referenced to Drawings, both on floor plans and in door and frame schedule. e. Explanation of abbreviations, symbols, and codes contained in schedule. f. Mounting locations for door hardware. g. Door and frame sizes and materials. h. Warranty information for each product. i. Operational narratives for electrified hardware. 4. Submittal Sequence: Submit the final Door Hardware Schedule at earliest possible date, particularly where approval of the Door Hardware Schedule must precede fabrication of other work that is critical in the Project construction schedule. Include Product Data, Samples, Shop Drawings of other work affected by door hardware, and other information essential to the coordinated review of the Door Hardware Schedule. C. Shop Drawings: Details of electrified access control hardware indicating the following: 1. Wiring Diagrams: Upon receipt of approved schedules, submit detailed system wiring diagrams for power, signaling, monitoring, communication, and control of the access control system electrified hardware. Differentiate between manufacturer-installed and field-installed wiring. Include the following: a. Elevation diagram of each unique access controlled opening showing location and interconnection of major system components with respect to their placement in the respective door openings. 2. Point to Point Wiring Diagrams: Upon receipt of approved schedules, submit detailed system wiring diagrams for power, signaling, monitoring, communication, and control of the access control system electrified hardware. Differentiate between manufacturer- installed and field-installed wiring. Include the following: a. Complete (risers, point-to-point) access control system block wiring diagrams. b. Wiring instructions for each electronic component scheduled herein. 3. Electrical Coordination: Coordinate with related sections the voltages and wiring details required at electrically controlled and operated hardware openings. D. Keying Schedule: After a keying meeting with the owner has taken place prepare a separate keying schedule detailing final instructions. Submit the keying schedule in electronic format. Include keying system explanation, door numbers, key set symbols, hardware set numbers and special instructions. Owner must approve submitted keying schedule prior to the ordering of permanent cylinders/cores. E. Informational Submittals: 1. Product Test Reports: Indicating compliance with cycle testing requirements, based on evaluation of comprehensive tests performed by manufacturer and witnessed by a qualified independent testing agency. F. Operating and Maintenance Manuals: Provide manufacturers operating and maintenance manuals for each item comprising the complete door hardware installation in quantity as required in Division 01, Closeout Procedures. 1. Maintenance manual must be provided for tornado/hurricane storm shelter impact protective systems. 1.3 QUALITY ASSURANCE A. Manufacturers Qualifications: Engage qualified manufacturers with a minimum 5 years of documented experience in producing hardware and equipment similar to that indicated for this Project and that have a proven record of successful in-service performance. CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 3 B. Installer Qualifications: A minimum 3 years documented experience installing both standard and electrified door hardware similar in material, design, and extent to that indicated for this Project and whose work has resulted in construction with a record of successful in-service performance. C. Door Hardware Supplier Qualifications: Experienced commercial door hardware distributors with a minimum 5 years documented experience supplying both mechanical and electromechanical hardware installations comparable in material, design, and extent to that indicated for this Project. Supplier recognized as a factory direct distributor by the manufacturers of the primary materials with a warehousing facility in Project's vicinity. Supplier to have on staff a certified Architectural Hardware Consultant (AHC) available during the course of the Work to consult with Contractor, Architect, and Owner concerning both standard and electromechanical door hardware and keying. D. Automatic Operator Supplier Qualifications: Suppliers are to be factory trained, certified, and a direct purchaser of the specified power operators and be responsible for the installation and maintenance of the units and accessories indicated for the Project. E. Source Limitations: Obtain each type and variety of door hardware specified in this section from a single source unless otherwise indicated. 1. Electrified modifications or enhancements made to a source manufacturer's product line by a secondary or third party source will not be accepted. 2. Provide electromechanical door hardware from the same manufacturer as mechanical door hardware, unless otherwise indicated. F. Storm Shelter Openings: Provide complete door systems for hurricane or tornado resistant storm shelters and other areas of refuge complying and tested according to ICC 500 (2014/2020), ICC/NSSA Standard for the Design and Construction of Storm Shelters. G. Each unit to bear third party permanent label indicating compliance with the referenced testing standards. H. Keying Conference: Conduct conference to comply with requirements in Division 01 Section "Project Meetings." Keying conference to incorporate the following criteria into the final keying schedule document: 1. Function of building, purpose of each area and degree of security required. 2. Plans for existing and future key system expansion. 3. Requirements for key control storage and software. 4. Installation of permanent keys, cylinder cores and software. 5. Address and requirements for delivery of keys. I. Pre-Submittal Conference: Conduct coordination conference in compliance with requirements in Division 01 Section "Project Meetings" with attendance by representatives of Supplier(s), Installer(s), and Contractor(s) to review proper methods and the procedures for receiving, handling, and installing door hardware. 1. Prior to installation of door hardware, conduct a project specific training meeting to instruct the installing contractors' personnel on the proper installation and adjustment of their respective products. Product training to be attended by installers of door hardware (including electromechanical hardware) for aluminum, hollow metal and wood doors. Training will include the use of installation manuals, hardware schedules, templates and physical product samples as required. 2. Inspect and discuss electrical roughing-in, power supply connections, and other preparatory work performed by other trades. 3. Review sequence of operation narratives for each unique access controlled opening. 4. Review and finalize construction schedule and verify availability of materials. J. Pre-Installation Conference: Conduct coordination conference in compliance with requirements in Division 01 Section "Project Meetings" with attendance by representatives of Supplier(s), Installer(s), and Contractor(s) to review proper methods and the procedures for installing door hardware. CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 4 1. Prior to installation of door hardware, door hardware supplier shall conduct a project specific training meeting to instruct the installing contractors' personnel on the proper installation and adjustment of their respective products. Product training to be attended by installers of door hardware (including electromechanical hardware) for aluminum, hollow metal and wood doors. Training will include the use of installation manuals, hardware schedules, templates and physical product samples as required. 2. Hardware supplier shall engage factory personnel for installation training on locks, exit devices and door closers. K. At completion of installation, provide written documentation that components were applied according to manufacturer's instructions and recommendations and according to approved schedule. 1.4 DELIVERY, STORAGE, AND HANDLING A. Inventory door hardware on receipt and provide secure lock-up and shelving for door hardware delivered to Project site. Do not store electronic access control hardware, software or accessories at Project site without prior authorization. B. Tag each item or package separately with identification related to the final Door Hardware Schedule, and include basic installation instructions with each item or package. C. Deliver, as applicable, permanent keys, cylinders, cores, access control credentials, software and related accessories directly to Owner via registered mail or overnight package service. Instructions for delivery to the Owner shall be established at the "Keying Conference". 1.5 COORDINATION A. Templates: Obtain and distribute to the parties involved templates for doors, frames, and other work specified to be factory prepared for installing standard and electrified hardware. Check Shop Drawings of other work to confirm that adequate provisions are made for locating and installing hardware to comply with indicated requirements. B. Door Hardware and Electrical Connections: Coordinate the layout and installation of scheduled electrified door hardware and related access control equipment with required connections to source power junction boxes, low voltage power supplies, detection and monitoring hardware, and fire and detection alarm systems. C. Door and Frame Preparation: Doors and corresponding frames are to be prepared, reinforced and pre-wired (if applicable) to receive the installation of the specified electrified, monitoring, signaling and access control system hardware without additional in-field modifications. 1.6 WARRANTY A. General Warranty: Reference Division 01, General Requirements. Special warranties specified in this Article shall not deprive Owner of other rights Owner may have under other provisions of the Contract Documents and shall be in addition to, and run concurrent with, other warranties made by Contractor under requirements of the Contract Documents. B. Warranty Period: Written warranty, executed by manufacturer(s), agreeing to repair or replace components of standard and electrified door hardware that fails in materials or workmanship within specified warranty period after final acceptance by the Owner. Failures include, but are not limited to, the following: 1. Structural failures including excessive deflection, cracking, or breakage. 2. Faulty operation of the hardware. 3. Deterioration of metals, metal finishes, and other materials beyond normal weathering. 4. Electrical component defects and failures within the systems operation. C. Warranty Period: Unless otherwise indicated, warranty shall be one year from date of Substantial Completion. D. Special Warranty Periods: 1. Ten years for mortise locks and latches. 2. Five years for exit hardware. 3. Twenty five years for manual surface door closer bodies. CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 5 4. Five years for motorized electric latch retraction exit devices. 5. Two years for electromechanical door hardware. 1.7 MAINTENANCE SERVICE A. Maintenance Tools and Instructions: Furnish a complete set of specialized tools and maintenance instructions as needed for Owner's continued adjustment, maintenance, and removal and replacement of door hardware. B. Storm Shelter Openings: Furnish a complete set of operational and maintenance instructions as needed for Owner's continued adjustment, maintenance, and repairs of door hardware as required by ICC 500 (2020), ICC/NSSA Standard for the Design and Construction of Storm Shelters. PART 2 - PRODUCTS 2.1 SCHEDULED DOOR HARDWARE A. General: Provide door hardware for each door to comply with requirements in Door Hardware Sets and each referenced section that products are to be supplied under. B. Designations: Requirements for quantity, item, size, finish or color, grade, function, and other distinctive qualities of each type of door hardware are indicated in the Door Hardware Sets at the end of Part 3. Products are identified by using door hardware designations, as follows: 1. Named Manufacturer's Products: Product designation and manufacturer are listed for each door hardware type required for the purpose of establishing requirements. Manufacturers' names are abbreviated in the Door Hardware Schedule. C. Please note that ASSA ABLOY is transitioning the Yale Commercial brand to Arrow. This affects only the brand name; the products and product numbers will remain unchanged. The brand transition is expected to be complete in or about May of 2024, and products shipping after that time will be branded Arrow. D. Substitutions: Requests for substitution and product approval for inclusive mechanical and electromechanical door hardware in compliance with the specifications must be submitted in writing and in accordance with the procedures and time frames outlined in Division 01, Substitution Procedures. Approval of requests is at the discretion of the architect, owner, and their designated consultants. 2.2 HANGING DEVICES A. Hinges: ANSI/BHMA A156.1 butt hinges with number of hinge knuckles and other options as specified in the Door Hardware Sets. Quantities in hardware sets are intended to follow the criteria below. If there is a conflict the information below should be followed. 1. Quantity: Provide the following hinge quantity: a. Two Hinges: For doors with heights up to 60 inches. b. Three Hinges: For doors with heights 61 to 90 inches. c. Four Hinges: For doors with heights 91 to 120 inches. d. For doors with heights more than 120 inches, provide 4 hinges, plus 1 hinge for every 30 inches of door height greater than 120 inches. 2. Hinge Size: Provide the following, unless otherwise indicated, with hinge widths sized for door thickness and clearances required: a. Widths up to 3’0”: 4-1/2” standard or heavy weight as specified. b. Sizes from 3’1” to 4’0”: 5” standard or heavy weight as specified. 3. Hinge Weight and Base Material: Unless otherwise indicated, provide the following: a. Exterior Doors: Heavy weight, non-ferrous, ball bearing or oil impregnated bearing hinges unless Hardware Sets indicate standard weight. b. Interior Doors: Standard weight, steel, ball bearing or oil impregnated bearing hinges unless Hardware Sets indicate heavy weight. 4. Hinge Options: Comply with the following: a. Non-removable Pins: With the exception of electric through wire hinges, provide set screw in hinge barrel that, when tightened into a groove in hinge pin, prevents removal of pin while door is closed; for the all out-swinging lockable doors. CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 6 5. Manufacturers: a. Ives (IV) - 5BB Series, 5 knuckle. b. McKinney (MK) - TA/T4A Series, 5 knuckle. c. dormakaba Best (ST) - F/FBB Series, 5 knuckle. B. Hinges at Storm Shelter Assemblies: At a minimum, provide heavy weight hinges with stainless steel screws used in accordance with and specified as part of a Severe Storm Shelter Opening meeting ICC 500 and FEMA 361. 1. Quantity: Provide the following hinge quantity: a. Three Hinges: For shutters with heights 36 to 60 inches, and doors at height of 80 inches. b. Four Hinges: For shutters with heights > 60 inches to 80 inches, and doors with heights greater than 84 inches. 2. Quantity: Provide the following hinge quantity: a. Three Hinges: For shutters with heights 36 to 60 inches, and doors at height of 80 inches. b. Four Hinges: For shutters with heights > 60 inches to 80 inches, and doors with heights greater than 84 inches. c. Hinge Size: Provide the following, unless otherwise indicated, with hinge widths sized for door thickness and clearances required: d. Widths up to 3’0”: 4-1/2” standard or heavy weight as specified. e. Sizes from 3’1” to 4’0”: 5” standard or heavy weight as specified. 3. Hinge Size: Provide the following, unless otherwise indicated, with hinge widths sized for door thickness and clearances required: a. Widths up to 3’0”: 4-1/2” standard or heavy weight as specified. b. Sizes from 3’1” to 4’0”: 5” standard or heavy weight as specified. 4. Hinge Weight and Base Material: At a minimum, provide heavy weight hinges with stainless steel screws used in accordance with and specified as part of a certified Storm Shelter Opening meeting ICC 500. 5. Manufacturers: a. McKinney (MK) - SP3386/SP3786. b. No Substitution. C. Continuous Geared Hinges: ANSI/BHMA A156.26 Grade 1-600 continuous geared hinge. with minimum 0.120-inch thick extruded 6063-T6 aluminum alloy hinge leaves and a minimum overall width of 4 inches. Hinges are non-handed, reversible and fabricated to template screw locations. Factory trim hinges to suit door height and prepare for electrical cut-outs. 1. Manufacturers:. a. Ives (IV). b. Pemko (PE). c. Select Hinges (SL). 2.3 SLIDING AND FOLDING HARDWARE A. Sliding and Folding Door Hardware: Hardware is to be of type and design as specified and should conform with ANSI/BHMA A156.14. 1. Bi-folding Door Hardware: Rated for door panels weighing up to 125 lb. 2. Manufacturers: a. Hafele Manufacturing (HF). b. Pemko (PE). c. KN Crowder (KN). 2.4 POWER TRANSFER DEVICES A. Electrified Quick Connect Transfer Hinges: Provide electrified transfer hinges with Molex™ standardized plug connectors and sufficient number of concealed wires (up to 12) to accommodate the electrified functions specified in the Door Hardware Sets with a 1-year warranty. Connectors plug directly to through-door wiring harnesses for connection to electric locking devices and power supplies. Wire nut connections are not acceptable. CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 7 1. Manufacturers: a. Ives (IV) - Connect. b. McKinney (MK) - QC Option. c. Dormakaba Best (ST) - C Option. B. Concealed Quick Connect Electric Power Transfers: Provide concealed wiring pathway housing mortised into the door and frame for low voltage electrified door hardware. Furnish with Molex™ standardized plug connectors and sufficient number of concealed wires (up to 12) to accommodate the electrified functions specified in the Door Hardware Sets. Connectors plug directly to through-door wiring harnesses for connection to electric locking devices and power supplies. Wire nut connections are not acceptable. 1. Manufacturers: a. Securitron (SU) - EL-CEPT Series. b. Dormakaba Best (ST) EPT-12C Series. c. Von Duprin (VD) - EPT-10 Series. C. Electric Door Wire Harnesses: Provide electric/data transfer wiring harnesses with standardized plug connectors to accommodate up to twelve (12) wires. Connectors plug directly to through- door wiring harnesses for connection to electric locking devices and power supplies. Provide sufficient number and type of concealed wires to accommodate electric function of specified hardware. Provide a connector for through-door electronic locking devices and from hinge to junction box above the opening. Wire nut connections are not acceptable. Determine the length required for each electrified hardware component for the door type, size and construction, minimum of two per electrified opening. 1. Provide one each of the following tools as part of the base bid contract: a. McKinney (MK) - Electrical Connecting Kit: QC-R001. b. McKinney (MK) - Connector Hand Tool: QC-R003. c. Similar tools by selected hinge manufacturer are acceptable. 2. Manufacturers: a. McKinney (MK) - QC-C Series. b. Dormakaba Best (ST) - WH Series. c. Von Duprin (VD) - Connect. D. Provide mortar guard enclosure on steel frames installed at masonry openings for each electrical hinge specified. 2.5 DOOR OPERATING TRIM A. Flush Bolts and Surface Bolts: Provide products conforming to ANSI/BHMA A156.3 and A156.16, Grade 1. 1. Flush bolts to be furnished with top rod of sufficient length to allow bolt retraction device location approximately six feet from the floor. 2. Furnish dust proof strikes for bottom bolts. 3. Surface bolts to be minimum 8” in length and U.L. listed for labeled fire doors and U.L. listed for windstorm components where applicable. 4. Provide related accessories (mounting brackets, strikes, coordinators, etc.) as required for appropriate installation and operation. 5. Manufacturers: a. Ives (IV). b. Rockwood (RO). c. Trimco (TC). B. Door Push Plates and Pulls: ANSI/BHMA A156.6 door pushes and pull units of type and design specified in the Hardware Sets. Coordinate and provide proper width and height as required where conflicting hardware dictates. 1. Push/Pull Plates: Minimum .050 inch thick, size as indicated in hardware sets, with beveled edges, secured with exposed screws unless otherwise indicated. 2. Door Pull and Push Bar Design: Size, shape, and material as indicated in the hardware sets. Minimum clearance of 2 1/2-inches from face of door unless otherwise indicated. CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 8 3. Offset Pull Design: Size, shape, and material as indicated in the hardware sets. Minimum clearance of 2 1/2-inches from face of door and offset of 90 degrees unless otherwise indicated. 4. Pulls, where applicable, shall be provided with a 10” clearance from the finished floor on the push side to accommodate wheelchair accessibility. 5. Fasteners: Provide manufacturer's designated fastener type as indicated in Hardware Sets. 6. Manufacturers: a. Ives (IV). b. Rockwood (RO). c. Trimco (TC). 2.6 CYLINDERS AND KEYING A. General: Cylinder manufacturer to have minimum (10) years experience designing secured master key systems and have on record a published security keying system policy. B. Cylinder Types: Original manufacturer cylinders able to supply the following cylinder formats and types: 1. Threaded mortise cylinders with rings and cams to suit hardware application. 2. Rim cylinders with back plate, flat-type vertical or horizontal tailpiece, and raised trim ring. 3. Bored or cylindrical lock cylinders with tailpieces as required to suit locks. 4. Tubular deadlocks and other auxiliary locks. 5. Mortise and rim cylinder collars to be solid and recessed to allow the cylinder face to be flush and be free spinning with matching finishes. 6. Keyway: Manufacturer’s Standard. C. Large Format Interchangeable Cores: Provide removable cores (LFIC) as specified, core insert, removable by use of a special key, and for use with only the core manufacturer's cylinder and door hardware. D. Security Cylinders: ANSI/BHMA A156.5, Grade 1 Certified Products Directory (CPD) listed security cylinders and keys able to be used together under the same facility master or grandmaster key system. Cylinders to be factory keyed. 1. New security key systems shall not be established with products that have an expired patent. Expired systems shall only be specified and supplied to support existing systems. 2. Manufacturers: a. Corbin Russwin (RU) - Access 3 AS. b. Sargent (SA) - Degree DG2. E. Keying System: Each type of lock and cylinders to be factory keyed. 1. Supplier shall conduct a "Keying Conference" to define and document keying system instructions and requirements. 2. Furnish factory cut, nickel-silver large bow permanently inscribed with a visual key control number as directed by Owner. 3. New System: Key locks to a new key system as directed by the Owner. F. Key Quantity: Provide the following minimum number of keys: 1. Change Keys per Cylinder: Two (2) 2. Master Keys (per Master Key Level/Group): Five (5). 3. Construction Keys: Ten (10). 4. Construction Control Keys: Two (2). 5. Permanent Control Keys: Two (2). G. Construction Keying: Provide temporary keyed construction cores for all locks and cylinders. H. Key Registration List (Bitting List): 1. Provide keying transcript list to Owner's representative in the proper format for importing into key control software. 2. Provide transcript list in writing or electronic file as directed by the Owner. CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 9 2.7 KEY CONTROL A. Key Control Cabinet: Provide a key control system including envelopes, labels, and tags with self-locking key clips, receipt forms, 3-way visible card index, temporary markers, permanent markers, and standard metal cabinet. Key control cabinet shall have expansion capacity of 150% of the number of locks required for the project. 1. Manufacturers: a. Lund Equipment (LU). b. MMF Industries (MM). c. Telkee (TK). 2.8 MECHANICAL LOCKS AND LATCHING DEVICES A. Mortise Locksets, Grade 1 (Heavy Duty): ANSI/BHMA A156.13, Series 1000, Operational Grade 1 Certified Products Directory (CPD) listed. Locksets are to be manufactured with a corrosion resistant steel case and be field-reversible for handing without disassembly of the lock body. 1. Manufacturers: a. Corbin Russwin Hardware (RU) - ML2000 Series. b. dormakaba Best (BE) - 45H Series. c. Sargent Manufacturing (SA) - 8200 Series. d. Schlage (SC) - L9000 Series. B. Multi-Point Locksets, Storm Shelter: ANSI/BHMA A156.37, Certified Products Directory (CPD) listed three-point locking system device engineered for in-swinging and out-swinging door applications on windstorm safe shelter rooms. Extra heavy duty steel component construction securing the door to the frame at top, bottom and center latch positions. All three latching points are automatically activated when the device is locked. Multi-Point Deadlocking System shall be used only with doors, frames and associated hardware that have been engineered, tested and approved for a complete opening assembly system. 1. ANSI-BHMA listed to A156.37 Grade 1 for multi-point locks: a. Lever torque to retract all bolts less than 28 in.lb. b. Cycle tested to 1,000,000 cycles. 2. NFPA 80 and NFPA 101 life safety requirements. 3. UL10C, 3-hour fire rated openings. 4. Latchbolt Construction: a. Center Bolt to be one piece, ¾” throw anti-friction stainless steel latch and one piece, 1” throw, hardened stainless steel deadbolt; 2-3/4” standard backset. b. Top and Bottom Bolts to be ¾” x ¾” stainless steel square latchbolt with ¾” projection. 5. Independent top and bottom bolt projection shall be field adjustable: a. From the center mortise pocket. b. Ability to make field adjustments while the door is in the hung position without the removal of the door. c. Top and Bottom Bolts and the Center Mortise Case shall be factory installed into the door assembly. 6. Bottom strike shall be offset and reversible to accommodate alignment issues due to rough opening tolerances. 7. Devices must be able to accommodate sectional rose and lever trim to match the design style and architectural finishes of the balance of the lockset and latches as specified. 8. Devices must be available with electronic access control options for higher or everyday use and traceability. 9. Devices must be available with rod-dogging indicator options: a. Operated by single-point latching for non-emergency or normal use of the space. b. Ability to hold rods in a retracted state. c. Day-to-day operations with mortise lock only. d. Indicator to show status. 10. Manufacturers: CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 10 a. Corbin Russwin Hardware (RU) - FE6600 Series. b. Sargent Manufacturing (SA) - FM7300 Series. c. Schlage (SC) - LM9300. 2.9 ELECTROMECHANICAL LOCKING DEVICES A. Electromechanical Mortise Locksets, Grade 1 (Heavy Duty): ANSI/BHMA A156.13, Series 1000, Operational Grade 1 Certified Products Directory (CPD) listed, subject to same compliance standards and requirements as mechanical mortise locksets, electrified locksets to be of type and design as specified below and in the hardware sets. 1. Electrified Lock Options: Where indicated in the Hardware Sets, provide electrified options including: outside door lock/unlock trim control, latchbolt and lock/unlock status monitoring, deadbolt monitoring, and request-to-exit signaling. Support end-of-line resistors contained within the lock case. Unless otherwise indicated, provide electrified locksets standard as fail secure. 2. Energy Efficient Design: Provide lock bodies which have a holding current draw of 15mA maximum, and can operate on either 12 or 24 volts. Locks are to be field configurable for fail safe or fail secure operation. 3. Manufacturers: a. Corbin Russwin Hardware (RU) - ML20900 Series. b. dormakaba Best (BE) - 45HW EL/EU Series. c. Sargent Manufacturing (SA) - 8200 Series. d. Schlage (SC) - L9000 EL/EU/RX Series. 2.10 LOCK AND LATCH STRIKES A. Strikes: Provide manufacturer's standard strike with strike box for each latch or lock bolt, with curved lip extended to protect frame, finished to match door hardware set, unless otherwise indicated, and as follows: 1. Flat-Lip Strikes: For locks with three-piece antifriction latchbolts, as recommended by manufacturer. 2. Extra-Long-Lip Strikes: For locks used on frames with applied wood casing trim. 3. Aluminum-Frame Strike Box: Provide manufacturer's special strike box fabricated for aluminum framing. 4. Double-lipped strikes: For locks at double acting doors. Furnish with retractable stop for rescue hardware applications. B. Standards: Comply with the following: 1. Strikes for Mortise Locks and Latches: BHMA A156.13. 2. Strikes for Auxiliary Deadlocks: BHMA A156.36. 3. Dustproof Strikes: BHMA A156.16. 2.11 CONVENTIONAL EXIT DEVICES A. General Requirements: All exit devices specified herein shall meet or exceed the following criteria: 1. Exit devices shall have a five-year warranty. 2. At doors not requiring a fire rating, provide devices complying with NFPA 101 and listed and labeled for "Panic Hardware" according to UL305. Provide proper fasteners as required by manufacturer including sex nuts and bolts at openings specified in the Hardware Sets. 3. Where exit devices are required on fire rated doors, provide devices complying with NFPA 80 and with UL labeling indicating "Fire Exit Hardware". Provide devices with the proper fasteners for installation as tested and listed by UL. Consult manufacturer’s catalog and template book for specific requirements. 4. Except on fire rated doors, provide exit devices with hex key dogging device to hold the pushbar and latch in a retracted position. Provide optional keyed cylinder dogging on devices where specified in Hardware Sets. CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 11 5. Devices must fit flat against the door face with no gap that permits unauthorized dogging of the push bar. The addition of filler strips is required in any case where the door light extends behind the device as in a full glass configuration. 6. Lever Operating Trim: Where exit devices require lever trim, furnish manufacturer's heavy duty escutcheon trim with threaded studs for thru-bolts. a. Lock Trim Design: As indicated in Hardware Sets, provide finishes and designs to match that of the specified locksets. b. Where function of exit device requires a cylinder, provide a cylinder (Rim or Mortise) as specified in Hardware Sets. 7. Vertical Rod Exit Devices: Where surface or concealed vertical rod exit devices are used at interior openings, provide as less bottom rod (LBR) unless otherwise indicated. Provide dust proof strikes where thermal pins are required to project into the floor. 8. Narrow Stile Applications: At doors constructed with narrow stiles, or as specified in Hardware Sets, provide devices designed for maximum 2” wide stiles. 9. Dummy Push Bar: Nonfunctioning push bar matching functional push bar. 10. Rail Sizing: Provide exit device rails factory sized for proper door width application. 11. Through Bolt Installation: For exit devices and trim as indicated in Door Hardware Sets. B. Conventional Push Rail Exit Devices (Heavy Duty): ANSI/BHMA A156.3, Grade 1 Certified Products Directory (CPD) listed panic and fire exit hardware devices furnished in the functions specified in the Hardware Sets. 1. Exit devices shall have narrow or wide style exterior trim as specified in the hardware sets. 2. Concealed vertical rod exit devices shall have center case adjustability. 3. Exit devices shall not require wire routing through the door for electromechanical functions. 4. Manufacturers: a. Corbin Russwin Hardware (RU) - PED4000 / PED5000 Series. b. Sargent Manufacturing (SA) - PE80 Series. c. Von Duprin (VD) - 353A/99 XP Series. C. Steel Removable Mullions: ANSI/BHMA A156.3 steel removable mullions with options for fire rating, locking, through-wire electrification and hurricane compliance as specified. 1. Manufacturers: a. Same as exit device manufacturer. 2.12 ELECTROMECHANICAL EXIT DEVICES A. Electromechanical Push Rail Exit Devices (Heavy Duty): ANSI/BHMA A156.3, Grade 1 Certified Products Directory (CPD) listed panic and fire exit hardware devices subject to same compliance standards and requirements as mechanical exit devices. Electrified exit devices to be of type and design as specified below and in the hardware sets. 1. Energy Efficient Design: Provide devices which have a holding current draw of 15mA maximum, and can operate on either 12 or 24 volts. Locks are to be field configurable for fail safe or fail secure operation. 2. Where conventional power supplies are not sufficient, include any specific controllers required to provide the proper inrush current. 3. Manufacturers: a. Corbin Russwin Hardware (RU) - ED5000 Series. b. Sargent Manufacturing (SA) - 80 Series. c. Von Duprin (VD) - 33A/99 XP Series. 2.13 DOOR CLOSERS A. All door closers specified herein shall meet or exceed the following criteria: CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 12 1. General: Door closers to be from one manufacturer, matching in design and style, with the same type door preparations and templates regardless of application or spring size. Closers to be non-handed with full sized covers. 2. Standards: Closers to comply with UL-10C for Positive Pressure Fire Test and be U.L. listed for use of fire rated doors. 3. Size of Units: Comply with manufacturer's written recommendations for sizing of door closers depending on size of door, exposure to weather, and anticipated frequency of use. Where closers are indicated for doors required to be accessible to the Americans with Disabilities Act, provide units complying with ANSI ICC/A117.1. 4. Closer Arms: Provide heavy duty, forged steel closer arms unless otherwise indicated in Hardware Sets. 5. Closers shall not be installed on exterior or corridor side of doors; where possible install closers on door for optimum aesthetics. 6. Closer Accessories: Provide door closer accessories including custom templates, special mounting brackets, spacers and drop plates as required for proper installation. Provide through-bolt and security type fasteners as specified in the hardware sets. B. Door Closers, Surface Mounted (Large Body Cast Iron): ANSI/BHMA A156.4, Grade 1 Certified Products Directory (CPD) listed surface mounted, heavy duty door closers with complete spring power adjustment, sizes 1 thru 6; and fully operational adjustable according to door size, frequency of use, and opening force. Closers to be rack and pinion type, one piece cast iron body construction, with adjustable backcheck and separate non-critical valves for closing sweep and latch speed control. 1. Large body cast iron surface mounted door closers shall have a 30-year warranty. 2. Manufacturers: a. Sargent Manufacturing (SA) - 281 Series. b. No Substitution. C. Door Closers, Surface Mounted (Heavy Duty): ANSI/BHMA A156.4, Grade 1 Certified Products Directory (CPD) listed surface mounted, heavy duty door closers with complete spring power adjustment, sizes 1 thru 6; and fully operational adjustable according to door size, frequency of use, and opening force. Closers to be rack and pinion type, one piece cast iron or aluminum alloy body construction, with adjustable backcheck and separate non-critical valves for closing sweep and latch speed control. Provide non-handed units standard. 1. Heavy duty surface mounted door closers shall have a 30-year warranty. 2. Manufacturers: a. Arrow, formerly known as Yale (YA) - 4400 Series. b. Corbin Russwin Hardware (RU) - DC6000 Series. c. LCN Closers (LC) - 4040 Series. d. Sargent Manufacturing (SA) - 351 Series. D. Door Closers, Overhead Concealed (Narrow Profile): ANSI/BHMA 156.4 Grade 1 Certified Products Directory (CPD) listed door closers designed for narrow profile frames and doors. Closers to have fully concealed body in the frame head for offset hung applications, with separate and independent valves for closing speed and backcheck adjustments and a decorative cover plate. 1. Manufacturers: a. dormakaba (DO) - RTS88 Series. b. ASSA Abloy Glass Solutions (GS) – OHC-609 Series. 2.14 ELECTROMECHANICAL DOOR OPERATORS A. General: Provide low energy operators of size recommended by manufacturer for door size, weight, and movement; for condition of exposure; and for compliance with UL 325. Coordinate operator mechanisms with door operation, hinges, and activation devices. 1. Fire-Rated Doors: Provide door operators for fire-rated door assemblies that comply with NFPA 80 for fire-rated door components and are listed and labeled by a qualified testing agency. CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 13 B. Standard: Conforming to ANSI/BHMA A156.19. C. Performance Requirements: 1. Opening Force if Power Fails: Not more than 15 lbf required to release a latch if provided, not more than 30 lbf required to manually set door in motion, and not more than 15 lbf required to fully open door. 2. Entrapment Protection: Not more than 15 lbf required to prevent stopped door from closing or opening. D. Configuration: Surface mounted or in-ground as required. Door operators to control single swinging and pair of swinging doors. E. Operation: Power opening and spring closing operation capable of meeting ANSI A117.1 accessibility guideline. Provide time delay for door to remain open before initiating closing cycle as required by ANSI/BHMA A156.19. F. Features: Operator units to have full feature adjustments for door opening and closing force and speed, backcheck, motor assist acceleration from 0 to 30 seconds, time delay, vestibule interface delay, obstruction recycle, and hold open time from 0 up to 30 seconds. G. Provide outputs and relays on board the operator to allow for coordination of exit device latch retraction, electric strikes, magnetic locks, card readers, safety and motion sensors and specified auxiliary contacts. H. Provide on/off/hold key switch for all automatic operators. I. Brackets and Reinforcements: Manufacturer's standard, fabricated from aluminum with nonferrous shims for aligning system components. J. Manufacturers: Subject to compliance with requirements, provide products by one of the following: 1. Besam Automated Entrance Systems (BE) - SW200i Series. 2. Horton Automatics (HO) - 4100 Series. 3. Stanley Security Solutions (ST) - Magic Force Series. 2.15 ARCHITECTURAL TRIM A. Door Protective Trim 1. General: Door protective trim units to be of type and design as specified below or in the Hardware Sets. 2. Size: Fabricate protection plates (kick, armor, or mop) not more than 2" less than door width (LDW) on stop side of single doors and 1” LDW on stop side of pairs of doors, and not more than 1" less than door width on pull side. Coordinate and provide proper width and height as required where conflicting hardware dictates. Height to be as specified in the Hardware Sets. 3. Where plates are applied to fire rated doors with the top of the plate more than 16” above the bottom of the door, provide plates complying with NFPA 80. Consult manufacturer’s catalog and template book for specific requirements for size and applications. 4. Protection Plates: ANSI/BHMA A156.6 protection plates (kick, armor, or mop), fabricated from the following: a. Stainless Steel: 300 grade, 050-inch thick. 5. Options and fasteners: Provide manufacturer's designated fastener type as specified in the Hardware Sets. Provide countersunk screw holes. 6. Manufacturers: a. Ives (IV). b. Rockwood (RO). c. Trimco (TC). 2.16 DOOR STOPS AND HOLDERS A. General: Door stops and holders to be of type and design as specified below or in the Hardware Sets. CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 14 B. Door Stops and Bumpers: ANSI/BHMA A156.16, Grade 1 door stops and wall bumpers. Provide wall bumpers, either convex or concave types with anchorage as indicated, unless floor or other types of door stops are specified in Hardware Sets. Do not mount floor stops where they will impede traffic. Where floor or wall bumpers are not appropriate, provide overhead type stops and holders. 1. Manufacturers: a. Ives (IV). b. Rockwood (RO). c. Trimco (TC). C. Overhead Door Stops and Holders: ANSI/BHMA A156.8, Grade 1 Certified Products Directory (CPD) listed overhead stops and holders to be surface or concealed types as indicated in Hardware Sets. Track, slide, arm and jamb bracket to be constructed of extruded bronze and shock absorber spring of heavy tempered steel. Provide non-handed design with mounting brackets as required for proper operation and function. 1. Manufacturers: a. Norton Rixson (RF). b. Architectural Builders Hardware (AH). c. Glynn Johnson (GJ). 2.17 ARCHITECTURAL SEALS A. General: Thresholds, weatherstripping, and gasket seals to be of type and design as specified below or in the Hardware Sets. Provide continuous weatherstrip gasketing on exterior doors and provide smoke, light, or sound gasketing on interior doors where indicated. At exterior applications provide non-corrosive fasteners and elsewhere where indicated. B. Smoke Labeled Gasketing: Assemblies complying with NFPA 105 that are listed and labeled by a testing and inspecting agency acceptable to authorities having jurisdiction, for smoke control ratings indicated, based on testing according to UL 1784. 1. Provide smoke labeled perimeter gasketing at all smoke labeled openings. C. Fire Labeled Gasketing: Assemblies complying with NFPA 80 that are listed and labeled by a testing and inspecting agency acceptable to authorities having jurisdiction, for fire ratings indicated, based on testing according to UL-10C. 1. Provide intumescent seals as indicated to meet UL10C Standard for Positive Pressure Fire Tests of Door Assemblies, and NPFA 252, Standard Methods of Fire Tests of Door Assemblies. D. Sound-Rated Gasketing: Assemblies that are listed and labeled by a testing and inspecting agency, for sound ratings indicated. E. Replaceable Seal Strips: Provide only those units where resilient or flexible seal strips are easily replaceable and readily available from stocks maintained by manufacturer. F. Manufacturers: 1. National Guard Products (NG). 2. Pemko (PE). 3. Zero (ZE). 2.18 ELECTRONIC ACCESSORIES A. Door Position Switches: Door position magnetic reed contact switches specifically designed for use in commercial door applications. On recessed models the contact and magnetic housing snap-lock into a 1" diameter hole. Surface mounted models include wide gap distance design complete with armored flex cabling. Provide SPDT, N/O switches with optional Rare Earth Magnet installation on steel doors with flush top channels. 1. Manufacturers: a. Sargent Manufacturing (SA) - 3280 Series. b. Security Door Controls (SD) - DPS Series. c. Securitron (SU) - DPS Series. d. Schlage Electronics (SE) – 679 Series (ADD 2) CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 15 2.19 FABRICATION A. Fasteners: Provide door hardware manufactured to comply with published templates generally prepared for machine, wood, and sheet metal screws. Provide screws according to manufacturers recognized installation standards for application intended. 2.20 FINISHES A. Standard: Designations used in the Hardware Sets and elsewhere indicate hardware finishes complying with ANSI/BHMA A156.18, including coordination with traditional U.S. finishes indicated by certain manufacturers for their products. B. Provide quality of finish, including thickness of plating or coating (if any), composition, hardness, and other qualities complying with manufacturer's standards, but in no case less than specified by referenced standards for the applicable units of hardware C. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine scheduled openings, with Installer present, for compliance with requirements for installation tolerances, labeled fire door assembly construction, wall and floor construction, and other conditions affecting performance. B. Notify architect of any discrepancies or conflicts between the door schedule, door types, drawings and scheduled hardware. Proceed only after such discrepancies or conflicts have been resolved in writing. 3.2 PREPARATION A. Hollow Metal Doors and Frames: Comply with ANSI/DHI A115 series. B. Wood Doors: Comply with ANSI/DHI A115-W series. 3.3 INSTALLATION A. Install each item of mechanical and electromechanical hardware and access control equipment to comply with manufacturer's written instructions and according to specifications. 1. Installers are to be trained and certified by the manufacturer on the proper installation and adjustment of fire, life safety, and security products including: hanging devices; locking devices; closing devices; and seals. B. Mounting Heights: Mount door hardware units at heights indicated in following applicable publications, unless specifically indicated or required to comply with governing regulations: 1. Standard Steel Doors and Frames: DHI's "Recommended Locations for Architectural Hardware for Standard Steel Doors and Frames." 2. DHI TDH-007-20: Installation Guide for Doors and Hardware. 3. Where indicated to comply with accessibility requirements, comply with ANSI A117.1 "Accessibility Guidelines for Buildings and Facilities." 4. Provide blocking in drywall partitions where wall stops or other wall mounted hardware is located. C. Power Operator products and accessories are required to be installed through current members of the manufacturer's "Power Operator Preferred Installer" program. D. Retrofitting: Install door hardware to comply with manufacturer's published templates and written instructions. Where cutting and fitting are required to install door hardware onto or into surfaces that are later to be painted or finished in another way, coordinate removal, storage, and reinstallation of surface protective trim units with finishing work specified in Division 9 Sections. Do not install surface-mounted items until finishes have been completed on substrates involved. E. Thresholds: Set thresholds for exterior and acoustical doors in full bed of sealant complying with requirements specified in Division 7 Section "Joint Sealants." CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 16 F. Storage: Provide a secure lock up for hardware delivered to the project but not yet installed. Control the handling and installation of hardware items so that the completion of the work will not be delayed by hardware losses before and after installation. 3.4 FIELD QUALITY CONTROL A. Field Inspection (Punch Report): Reference Division 01 Sections “Closeout Procedures”. Produce project punch report for each installed door opening indicating compliance with approved submittals and verification hardware is properly installed, operating and adjusted. Include list of items to be completed and corrected, indicating the reasons or deficiencies causing the Work to be incomplete or rejected. 1. Organization of List: Include separate Door Opening and Deficiencies and Corrective Action Lists organized by Mark, Opening Remarks and Comments, and related Opening Images and Video Recordings. B. Maintenance manual must be provided for tornado/hurricane storm shelter impact protective systems. 3.5 ADJUSTING A. Initial Adjustment: Adjust and check each operating item of door hardware and each door to ensure proper operation or function of every unit. Replace units that cannot be adjusted to operate as intended. Adjust door control devices to compensate for final operation of heating and ventilating equipment and to comply with referenced accessibility requirements. 3.6 CLEANING AND PROTECTION A. Protect all hardware stored on construction site in a covered and dry place. Protect exposed hardware installed on doors during the construction phase. Install any and all hardware at the latest possible time frame. B. Clean adjacent surfaces soiled by door hardware installation. C. Clean operating items as necessary to restore proper finish. Provide final protection and maintain conditions that ensure door hardware is without damage or deterioration at time of owner occupancy. 3.7 DEMONSTRATION A. Instruct Owner's maintenance personnel to adjust, operate, and maintain mechanical and electromechanical door hardware. 3.8 DOOR HARDWARE SETS A. The hardware sets represent the design intent and direction of the owner and architect. They are a guideline only and should not be considered a detailed hardware schedule. Discrepancies, conflicting hardware and missing items should be brought to the attention of the architect with corrections made prior to the bidding process. Omitted items not included in a hardware set should be scheduled with the appropriate additional hardware required for proper application and functionality. 1. Quantities listed are for each pair of doors, or for each single door. 2. The supplier is responsible for handing and sizing all products. 3. Where multiple options for a piece of hardware are given in a single line item, the supplier shall provide the appropriate application for the opening. B. Manufacturer’s Abbreviations: 1. MK - McKinney 2. PE - Pemko 3. KN - K.N. Crowder 4. GS - ASSA ABLOY Glass Solutions 5. RO - Rockwood 6. SA - SARGENT 7. AT - Accurate Lock and Hardware CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 17 8. SU - Securitron 9. AH - Architectural Builders Hardware 10. BM - Besam 11. ZE - Zero International 12. OT – Other 13. DD – D&D Technologies Hardware Sets Set: 1.0 Doors: EX-100 Description: Pair Exterior Vest AL (CR, ADA) 2 Continuous Hinge CFM SLI-HD1 PT PE 1 Concealed Vert Rod Exit, Nightlatch DG264 55 56 ADPE8410 P106 US32D SA 1 Concealed Vert Rod Exit, Exit Only 55 56 ADPE8410 EO US32D SA 1 Core DG2 6300 US15 SA 2 Door Pull RM3311-36 Mtg-Type 12XHD US32D RO 1 Conc Overhead Stop 102_SA US32D AH 1 Surface Closer 351 P10 581-2 351-D EN SA 1 Door Operator SW200i-OHC 689 BM 1 Threshold 2705AT PE 2 Sweep 315CN PE 2 Electric Power Transfer EL-CEPT 630 SU 2 ElectroLynx Harness QC-C Series (Frame) MK 2 ElectroLynx Harness QC-C Series (Door) MK 1 Bollard Post BPS-IG 6" Square AT (2) Prep DKBRZ OT 2 Position Switch DPS-M or W as Req'd SU 1 Actuator S-4x4-3 US32D WK 1 Card Reader By ACS Provider OT 1 On/Off/Hold Switch PS-4C BM 3 Panic Button By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Perimeter seal and astragal by door supplier. Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When devices are locked then the card reader grants access upon presentation of a valid credential. Exit devices mechanically lock during power failure with a mechanical key override entry. 2. Egress always free from inside by depressing inside push pad. 3. Request to exit switch in the push pad to signal authorized egress to the access control system. 4. Door position switch to signal door open/closed to the access control system. 5. Outside actuator switch powers the door operator. Switch is active only when doors are unlocked or a valid credential is presented. 6. Inside actuator switch always retracts the latch and powers the door operator. 7. Panic buttons to be mounted at reception desk 201, Records Tech 301 and in Vestibule 100. Depressing panic button will lock door EX-100. Set: 2.0 Doors: EX-361 CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 18 Description: Pair Exterior Police Entry AL (CR) 2 Continuous Hinge CFM SLI-HD1 PT PE 1 Concealed Vert Rod Exit, Nightlatch DG264 55 56 ADPE8410 P106 US32D SA 1 Concealed Vert Rod Exit, Exit Only 55 56 ADPE8410 EO US32D SA 1 Core DG2 6300 US15 SA 2 Door Pull RM3311-36 Mtg-Type 12XHD US32D RO 2 Conc Overhead Stop 102_SA US32D AH 2 Surface Closer 351 P10 581-2 351-D EN SA 1 Threshold 2705AT PE 2 Sweep 315CN PE 2 Electric Power Transfer EL-CEPT 630 SU 2 ElectroLynx Harness QC-C Series (Frame) MK 2 ElectroLynx Harness QC-C Series (Door) MK 2 Position Switch DPS-M or W as Req'd SU 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Perimeter seal and astragal by door supplier. Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When devices are locked then the card reader grants access upon presentation of a valid credential. Exit devices mechanically lock during power failure with a mechanical key override entry. 2. Egress always free from inside by depressing inside push pad. 3. Request to exit switch in the push pad to signal authorized egress to the access control system. 4. Door position switch to signal door open/closed to the access control system. Set: 3.0 Doors: EX-121D, EX-214, EX-221, EX-269, EX-326 Description: Single Exterior Fitness Center/ Kitchen/ Corridor/ Stair/ Break AL (CR) 1 Continuous Hinge CFM SLI-HD1 PT PE 1 Rim Exit Device, Storeroom DG264 55 56 PE8504 US32D SA 1 Core DG2 6300 US15 SA 1 Door Pull RM3311-36 Mtg-Type 12XHD US32D RO 1 Conc Overhead Stop 102_SA US32D AH 1 Surface Closer 351 P10 581-2 351-D EN SA 1 Threshold 2005AT PE 1 Sweep 315CN PE 1 Electric Power Transfer EL-CEPT 630 SU 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK 1 Position Switch DPS-M or W as Req'd SU 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Perimeter seal by door supplier. Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 19 control system. When devices are locked then the card reader grants access upon presentation of a valid credential. Exit devices mechanically lock during power failure with a mechanical key override entry. 2. Egress always free from the inside by depressing inside push pad. 3. Request to exit switch in the push pad to signal authorized egress to the access control system. 4. Door position switch to signal door open/closed to the access control system. 5. Provide push button mounted in Kitchen 214 to unlock door EX-214 only for a set time period. Set: 4.0 Doors: EX-101A, EX-101B, EX-121C Description: Single Exterior Lobby/ Fitness AL (RX, DPS) 1 Continuous Hinge CFM SLI-HD1 PT PE 1 Rim Exit Device, Exit Only 55 PE8510 EO US32D SA 1 Conc Overhead Stop 102_SA US32D AH 1 Surface Closer 351 P10 581-2 351-D EN SA 1 Threshold 2005AT PE 1 Sweep 315CN PE 1 Electric Power Transfer EL-CEPT 630 SU 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK 1 Position Switch DPS-M or W as Req'd SU Notes: Perimeter seal by door supplier. Operation: 1. Request to exit switch in the push pad to signal authorized egress to the access control system. 2. Door position switch to signal door open/closed to the access control system. Set: 5.0 Doors: EX-268, EX-420A, EX-420B Description: Single Exterior East Entry/ Garage (CR) 3 Hinge, Full Mortise, Hvy Wt T4A3386 NRP 4-1/2" x 4-1/2" US32D MK 1 Fail Secure Exit Device DG264 55 PE8876-24v WEP US32D SA 1 Core DG2 6300 US15 SA 1 Surface Closer 351 CPS EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Threshold 2705AT PE 1 Gasketing 2891AS (Head & Jambs) PE 1 Rain Guard 346C PE 1 Sweep 315CN PE 1 Electric Power Transfer EL-CEPT 630 SU 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK 1 Position Switch DPS-M or W as Req'd SU 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Install perimeter seal prior to closer, exit device, and strike. Do not notch weatherstrip. Special templating required. CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 20 Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When devices are locked then the card reader grants access upon presentation of a valid credential. Exit devices mechanically lock during power failure with a mechanical key override entry. 2. Egress always free from the inside by depressing inside push pad. 3. Request to exit switch in the push pad to signal authorized egress to the access control system. 4. Door position switch to signal door open/closed to the access control system. Set: 6.0 Doors: EX-430 Description: Single Exterior Processing (CR x 2, Delayed Egress) 3 Hinge, Full Mortise, Hvy Wt T4A3386 NRP 4-1/2" x 4-1/2" US32D MK 1 Fail Secure Delayed Egress Exit Device DG264 59 PE8876-24v WEP US32D SA 2 Core DG2 6300 US15 SA 1 Surface Closer 351 CPS EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Threshold 2705AT PE 1 Gasketing 2891AS (Head) PE 1 Gasketing 290AS (Jambs) PE 1 Rain Guard 346C PE 1 Sweep 315CN PE 1 Electric Power Transfer EL-CEPT 630 SU 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK 1 Position Switch DPS-M or W as Req'd SU 2 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Install perimeter seal prior to closer, exit device, and strike. Do not notch weatherstrip. Special templating required. Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When outside lever is locked the card reader grants access upon presentation of a valid credential. Lever mechanically locks during power failure. 2. Depressing the inside push pad will activate a delayed egress cycle. 3. When delayed egress cycle is activated the alarm will sound and the door will unlock after 15 second delay. 4. Alarm to be turned on/off through the access control system or keyed cylinder in the push pad. 5. Door position switch to signal door open/closed to the access control system. Set: 7.0 Doors: EX-280B Description: Single Exterior Roof (RX, DPS) 2 Hinge, Full Mortise, Hvy Wt T4A3386 4-1/2" x 4-1/2" US32D MK 1 Hinge, Full Mortise, Hvy Wt T4A3386 QC8 4-1/2" x 4-1/2" US32D MK 1 Storeroom/Closet Lock DG264 RX 8204 LNP US32D SA 1 Core DG2 6300 US15 SA 1 Surf Overhead Stop 902_A US32D AH CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 21 1 Surface Closer 351 PD10 EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Threshold 2705AT PE 1 Gasketing 2891AS (Head) PE 1 Gasketing 290AS (Jambs) PE 1 Rain Guard 346C PE 1 Sweep 315CN PE 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK 1 Position Switch DPS-M or W as Req'd SU Notes: Mount cylinder on interior side. Always free ingress from the roof. Install perimeter seal prior to closer. Do not notch weatherstrip. Special templating required. Operation: 1. Request to exit switch in lever to signal authorized ingress to the access control system. 2. Door position switch to signal door open/closed to the access control system. Set: 8.0 (ADD 02) Doors: EX-403C Description: Pair Exterior Mechanical (RX, DPS) 7 Hinge, Full Mortise, Hvy Wt T4A3386 NRP 5" x 4-1/2" US32D MK 1 Hinge, Full Mortise, Hvy Wt T4A3386 QC8 5" x 4-1/2" US32D MK 2 Flush Bolt 555 US26D RO 1 Dust Proof Strike 570 US26D RO 1 Storeroom/Closet Lock DG264 RX 8204 LNP 7/8" Lip Lgth US26D SA 1 Core DG2 6300 US15 SA 2 Surface Closer 351 CPS EN SA 2 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Threshold 2705AT PE 1 Gasketing 2891AS (Head) PE 1 Gasketing 290AS (Jambs) PE 1 Rain Guard 346C PE 2 Sweep 315CN PE 1 Astragal 357SP PE 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK 2 Position Switch DPS-M or W as Req'd SU Notes: Install perimeter seal prior to closer. Do not notch weatherstrip. Special templating required. Operation: 1. Request to exit switch in lever to signal authorized egress to the access control system. 2. Door position switch to signal door open/closed to the access control system. Set: 9.0 Doors: 100A Description: Pair Vest AL (CR, ADA) 2 Continuous Hinge CFM SLI-HD1 PT PE CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 22 1 Concealed Vert Rod Exit, Nightlatch DG264 55 56 ADPE8410 P106 US32D SA 1 Concealed Vert Rod Exit, Exit Only 55 56 ADPE8410 EO US32D SA 1 Core DG2 6300 US15 SA 2 Door Pull RM3311-36 Mtg-Type 12XHD US32D RO 1 Conc Overhead Stop 102_SA US32D AH 1 Surface Closer 351 P10 581-2 351-D EN SA 1 Door Operator SW200i-OHC 689 BM 2 Electric Power Transfer EL-CEPT 630 SU 2 ElectroLynx Harness QC-C Series (Frame) MK 2 ElectroLynx Harness QC-C Series (Door) MK 2 Position Switch DPS-M or W as Req'd SU 1 Actuator S-4x4-3 US32D WK 1 Dual Actuator S-NAR-3LR US32D WK 1 Card Reader By ACS Provider OT 1 On/Off/Hold Switch PS-4C BM 1 Power Supply By ACS Provider YA Notes: Perimeter seal and astragal by door supplier. Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When devices are locked then the card reader grants access upon presentation of a valid credential. Exit devices mechanically lock during power failure with a mechanical key override entry. 2. Egress always free from inside by depressing inside push pad. 3. Request to exit switch in the push pad to signal authorized egress to the access control system. 4. Door position switch to signal door open/closed to the access control system. 5. Outside actuator switch powers the door operator. Switch is active only when doors are unlocked or a valid credential is presented. 6. Inside actuator switch always retracts the latch and powers the door operator. Set: 10.0 Doors: 400B Description: Pair Indoor Garage (CR) 8 Hinge, Full Mortise, Hvy Wt T4A3786 NRP 5" x 4-1/2" US26D MK 1 Mullion L980S PC SA 1 Fail Secure Exit Device DG264 55 PE8876-24v WEP US32D SA 1 Rim Exit Device, Exit Only 55 PE8510 EO US32D SA 2 Core DG2 6300 US15 SA 1 Cylinder DG264 980C1 US26D SA 1 Surface Closer 351 P10 EN SA 1 Surface Closer 351 CPS EN SA 2 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 2 Wall Stop 406 US32D RO 1 Threshold 171A PE 1 Gasketing S88D PE 1 Mullion Gasketing 5110BL PE 2 Sweep 315CN PE 2 Electric Power Transfer EL-CEPT 630 SU 2 ElectroLynx Harness QC-C Series (Frame) MK 2 ElectroLynx Harness QC-C Series (Door) MK CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 23 2 Position Switch DPS-M or W as Req'd SU 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When devices are locked then the card reader grants access upon presentation of a valid credential. Exit devices mechanically lock during power failure with a mechanical key override entry. 2. Egress always free from the inside by depressing inside push pad. 3. Request to exit switch in the push pad to signal authorized egress to the access control system. 4. Door position switch to signal door open/closed to the access control system. Set: 11.0 Doors: 431A Description: Single Garage Vest (CR x 2, Delayed Egress) 3 Hinge, Full Mortise, Hvy Wt T4A3786 NRP 4-1/2" x 4-1/2" US26D MK 1 Fail Secure Delayed Egress Exit Device DG264 59 PE8876-24v WEP US32D SA 2 Core DG2 6300 US15 SA 1 Surface Closer 351 CPS EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Threshold 171A PE 1 Gasketing S88D PE 1 Sweep 315CN PE 1 Electric Power Transfer EL-CEPT 630 SU 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK 1 Position Switch DPS-M or W as Req'd SU 2 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When outside lever is locked the card reader grants access upon presentation of a valid credential. Lever mechanically locks during power failure. 2. Depressing the inside push pad will activate a delayed egress cycle. 3. When delayed egress cycle is activated the alarm will sound and the door will unlock after 15 second delay. 4. Alarm to be turned on/off through the access control system or keyed cylinder in the push pad. 5. Door position switch to signal door open/closed to the access control system. Set: 12.0 Doors: 124, 280, 341 Description: Single Stair Access/ Mech 3 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2" US26D MK 1 Storeroom Lock DG264 8204 LNP US32D SA 1 Core DG2 6300 US15 SA 1 Surface Closer 351 O EN SA CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 24 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 3 Silencer 608-RKW RO Set: 13.0 (PR 07) Doors: 230, 240 Description: Single Apparatus Bay 4 Hinge, Full Mortise, Hvy Wt T4A3786 NRP 4-1/2" x 4-1/2" US26D MK 1 Rim Exit Device, Classroom DG264 PE8813 WEP US32D SA 1 Classroom Lock DG264 8237 LNP US26D SA 1 Core DG2 6300 US15 SA 1 Surface Closer 351 CPS EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Threshold 171A PE 1 Gasketing 2891AS (Head) PE 1 Gasketing 290AS (Jambs) PE 1 Sweep 315CN PE Notes: Install perimeter seal prior to closer, exit device and strike. Do not notch weatherstrip. Special templating required. Set: 14.0 Doors: 102A Description: Single Training Room AL (CR) 1 Continuous Hinge CFM SLI-HD1 PT PE 1 Rim Exit Device, Storeroom DG264 55 56 PE8504 US32D SA 1 Core DG2 6300 US15 SA 1 Door Pull RM3311-24 Mtg-Type 12XHD US32D RO 1 Conc Overhead Stop 102_SA US32D AH 1 Surface Closer 351 P10 581-2 351-D EN SA 1 Electric Power Transfer EL-CEPT 630 SU 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK 1 Position Switch DPS-M or W as Req'd SU 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Perimeter seal by door supplier. Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When devices are locked then the card reader grants access upon presentation of a valid credential. Exit devices mechanically lock during power failure with a mechanical key override entry. 2. Egress always free from the inside by depressing inside push pad. 3. Request to exit switch in the push pad to signal authorized egress to the access control system. 4. Door position switch to signal door open/closed to the access control system. Set: 15.0 Doors: 102B CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 25 Description: Pair Training Room AL (CR) 2 Continuous Hinge CFM SLI-HD1 PT PE 1 Concealed Vert Rod Exit, Nightlatch DG264 55 56 ADPE8410 P106 US32D SA 1 Concealed Vert Rod Exit, Exit Only 55 56 ADPE8410 EO US32D SA 1 Core DG2 6300 US15 SA 2 Door Pull RM3311-24 Mtg-Type 12XHD US32D RO 2 Conc Overhead Stop 102_SA US32D AH 2 Surface Closer 351 P10 581-2 351-D EN SA 2 Electric Power Transfer EL-CEPT 630 SU 2 ElectroLynx Harness QC-C Series (Frame) MK 2 ElectroLynx Harness QC-C Series (Door) MK 2 Position Switch DPS-M or W as Req'd SU 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Perimeter seal and astragal by door supplier. Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When devices are locked then the card reader grants access upon presentation of a valid credential. Exit devices mechanically lock during power failure with a mechanical key override entry. 2. Egress always free from the inside by depressing inside push pad. 3. Request to exit switch in the push pad to signal authorized egress to the access control system. 4. Door position switch to signal door open/closed to the access control system. Set: 16.0 Doors: 211A, 211B Description: Single Fire Training 3 Hinge, Full Mortise, Hvy Wt T4A3786 4-1/2" x 4-1/2" US26D MK 1 Classroom Lock DG264 8237 LNP US26D SA 1 Core DG2 6300 US15 SA 1 Surface Closer 351 O EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 1 Gasketing S88D PE Set: 17.0 Doors: 301A Description: Single Records (CR) 2 Hinge, Full Mortise, Hvy Wt T4A3786 NRP 4-1/2" x 4-1/2" US26D MK 1 Hinge, Full Mortise, Hvy Wt T4A3786 QC8 4-1/2" x 4-1/2" US26D MK 1 Fail Secure Lock DG264 RX 8271-24V LNP US26D SA 1 Core DG2 6300 US15 SA 1 Surface Closer 351 P10 EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 3 Silencer 608-RKW RO 1 ElectroLynx Harness QC-C Series (Frame) MK CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 26 1 ElectroLynx Harness QC-C Series (Door) MK 1 Position Switch DPS-M or W as Req'd SU 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When outside lever is locked the card reader grants access upon presentation of a valid credential. Locksets mechanically lock during power failure with a mechanical key override entry. 2. Lever is always operational from the inside and retracts latch. 3. Request to exit switch in lever to signal authorized egress to the access control system. 4. Door position switch to signal door open/closed to the access control system. Set: 18.0 Doors: 431B Description: Single Processing (CR x 2) 2 Hinge, Full Mortise, Hvy Wt T4A3786 NRP 4-1/2" x 4-1/2" US26D MK 1 Hinge, Full Mortise, Hvy Wt T4A3786 QC8 4-1/2" x 4-1/2" US26D MK 1 Fail Secure Lock DG264 8273-24V LNP US26D SA 1 Core DG2 6300 US15 SA 1 Surface Closer 351 P10 EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 3 Silencer 608-RKW RO 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK 1 Position Switch DPS-M or W as Req'd SU 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When levers are locked the card reader from either side grants access upon presentation of a valid credential. Locksets mechanically lock during power failure with a mechanical key override entry. 2. Door position switch to signal door open/closed to the access control system. Set: 19.0 (PR 07) Doors: 102C, 306, 307, 331A, 331B, 332A, 332B, 354, 366A, 367, 368, 390A, 390B, 391A, 391B, 392, 393, 421, 431C Description: Single Conf/ Files/ Drying/ Training (CR) 2 Hinge, Full Mortise, Hvy Wt T4A3786 NRP 4-1/2" x 4-1/2" US26D MK 1 Hinge, Full Mortise, Hvy Wt T4A3786 QC8 4-1/2" x 4-1/2" US26D MK 1 Fail Secure Lock DG264 RX 8271-24V LNP US26D SA 1 Core DG2 6300 US15 SA 1 Surface Closer 351 O EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 27 3 Silencer 608-RKW RO 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK 1 Position Switch DPS-M or W as Req'd SU 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When outside lever is locked the card reader grants access upon presentation of a valid credential. Locksets mechanically lock during power failure with a mechanical key override entry. 2. Lever is always operational from the inside and retracts latch. 3. Request to exit switch in lever to signal authorized egress to the access control system. 4. Door position switch to signal door open/closed to the access control system. Set: 20.0 Doors: 102D, 364, 366B Description: Single Training Room/ Evidence/ Drying (CR) 2 Hinge, Full Mortise, Hvy Wt T4A3786 NRP 4-1/2" x 4-1/2" US26D MK 1 Hinge, Full Mortise, Hvy Wt T4A3786 QC8 4-1/2" x 4-1/2" US26D MK 1 Fail Secure Lock DG264 RX 8271-24V LNP US26D SA 1 Core DG2 6300 US15 SA 1 Surf Overhead Stop 902_A US32D AH 1 Surface Closer 351 O EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 3 Silencer 608-RKW RO 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK 1 Position Switch DPS-M or W as Req'd SU 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When outside lever is locked the card reader grants access upon presentation of a valid credential. Locksets mechanically lock during power failure with a mechanical key override entry. 2. Lever is always operational from the inside and retracts latch. 3. Request to exit switch in lever to signal authorized egress to the access control system. 4. Door position switch to signal door open/closed to the access control system. Set: 21.0 Doors: 365 Description: Single Bulk Evidence (CR) 2 Hinge, Full Mortise, Hvy Wt T4A3786 NRP 4-1/2" x 4-1/2" US26D MK 1 Hinge, Full Mortise, Hvy Wt T4A3786 QC8 4-1/2" x 4-1/2" US26D MK 1 Fail Secure Lock DG264 RX 8271-24V LNP US26D SA 1 Core DG2 6300 US15 SA CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 28 1 Surface Closer 351 CPS EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 3 Silencer 608-RKW RO 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK 1 Position Switch DPS-M or W as Req'd SU 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When outside lever is locked the card reader grants access upon presentation of a valid credential. Locksets mechanically lock during power failure with a mechanical key override entry. 2. Lever is always operational from the inside and retracts latch. 3. Request to exit switch in lever to signal authorized egress to the access control system. 4. Door position switch to signal door open/closed to the access control system. Set: 22.0 Doors: 121A Description: Single Training Room AL (CR) 1 Continuous Hinge CFM SLI-HD1 PT PE 1 Rim Exit Device, Storeroom DG264 55 56 PE8504 US32D SA 1 Core DG2 6300 US15 SA 1 Door Pull RM3311-24 Mtg-Type 12XHD US32D RO 1 Conc Overhead Stop 102_SA US32D AH 1 Surface Closer 351 P10 581-2 351-D EN SA 1 Electric Power Transfer EL-CEPT 630 SU 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK 1 Position Switch DPS-M or W as Req'd SU 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Perimeter seal by door supplier. Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When devices are locked then the card reader grants access upon presentation of a valid credential. Exit devices mechanically lock during power failure with a mechanical key override entry. 2. Egress always free from the inside by depressing inside push pad. 3. Request to exit switch in the push pad to signal authorized egress to the access control system. 4. Door position switch to signal door open/closed to the access control system. Set: 23.0 Doors: 121B Description: Single Fitness Center AL (CR x 2, Delayed Egress) 1 Continuous Hinge CFM SLI-HD1 PT PE 1 Fail Secure Delayed Egress Exit Device DG264 59 PE8574-24V NEP US32D SA CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 29 1 Core DG2 6300 US15 SA 1 Surface Closer 351 P10 581-2 351-D EN SA 1 Wall Stop 406 US32D RO 1 Electric Power Transfer EL-CEPT 630 SU 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK 1 Position Switch DPS-M or W as Req'd SU 2 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Perimeter seal by door supplier. Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When outside lever is locked the card reader grants access upon presentation of a valid credential. Lever mechanically locks during power failure. 2. Depressing the inside push pad will activate a delayed egress cycle. 3. When delayed egress cycle is activated the alarm will sound and the door will unlock after 15 second delay. 4. Alarm to be turned on/off through the access control system or keyed cylinder in the push pad. 5. Door position switch to signal door open/closed to the access control system. Set: 24.0 Doors: 110, 201 Description: Single Corridor (CR) 3 Hinge, Full Mortise, Hvy Wt T4A3786 NRP 4-1/2" x 4-1/2" US26D MK 1 Fail Secure Exit Device DG264 55 PE8876-24v WEP US32D SA 1 Core DG2 6300 US15 SA 1 Surface Closer 351 P10 EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 3 Silencer 608-RKW RO 1 Electric Power Transfer EL-CEPT 630 SU 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK 1 Position Switch DPS-M or W as Req'd SU 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When devices are locked then the card reader grants access upon presentation of a valid credential. Exit devices mechanically lock during power failure with a mechanical key override entry. 2. Egress always free from the inside by depressing inside push pad. 3. Request to exit switch in the push pad to signal authorized egress to the access control system. 4. Door position switch to signal door open/closed to the access control system. Set: 25.0 Doors: 114, 115, 116 CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 30 Description: Single Interview (CR) 2 Hinge, Full Mortise, Hvy Wt T4A3786 4-1/2" x 4-1/2" US26D MK 1 Hinge, Full Mortise, Hvy Wt T4A3786 QC8 4-1/2" x 4-1/2" US26D MK 1 Fail Secure Lock DG264 RX 8271-24V LNP US26D SA 1 Core DG2 6300 US15 SA 1 Surface Closer 351 O EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 1 Gasketing S88D PE 1 Door Bottom 369AA Z49-PL ZE 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK 1 Position Switch DPS-M or W as Req'd SU 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When outside lever is locked the card reader grants access upon presentation of a valid credential. Locksets mechanically lock during power failure with a mechanical key override entry. 2. Lever is always operational from the inside and retracts latch. 3. Request to exit switch in lever to signal authorized egress to the access control system. 4. Door position switch to signal door open/closed to the access control system. Set: 26.0 Doors: 432, 434, 435 Description: Single Interview (CR, Fail Safe) 3 Hinge, Full Mortise, Hvy Wt T4A3786 NRP 4-1/2" x 4-1/2" US26D MK 1 Security Deadbolt Lock DG264 8249 LNP US26D SA 2 Core DG2 6300 US15 SA 1 Surface Closer 351 CPS EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Electric Strike 1006CS Fail Safe 630 HS 1 Gasketing S88D PE 1 ElectroLynx Harness QC-C Series (Frame) MK 1 Position Switch DPS-M or W as Req'd SU 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Operation: 1. Card reader inside interview grants access upon presentation of a valid credential. Electric Strike to fail safe during power failure with mechanical key override entry. 2. Door position switch to signal door open/closed to the access control system. Set: 27.0 Doors: 104B Description: Single Kitchenette CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 31 3 Hinge, Full Mortise, Hvy Wt T4A3786 NRP 4-1/2" x 4-1/2" US26D MK 1 Classroom Lock DG264 8237 LNP US26D SA 1 Core DG2 6300 US15 SA 1 Surface Closer 351 CPSH EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 3 Silencer 608-RKW RO Set: 28.0 Doors: 104A Description: Single Vending (CR) 2 Hinge, Full Mortise, Hvy Wt T4A3786 NRP 4-1/2" x 4-1/2" US26D MK 1 Hinge, Full Mortise, Hvy Wt T4A3786 QC8 4-1/2" x 4-1/2" US26D MK 1 Fail Secure Lock DG264 RX 8271-24V LNP US26D SA 1 Core DG2 6300 US15 SA 1 Surface Closer 351 CPS EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 3 Silencer 608-RKW RO 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK 1 Position Switch DPS-M or W as Req'd SU 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When outside lever is locked the card reader grants access upon presentation of a valid credential. Locksets mechanically lock during power failure with a mechanical key override entry. 2. Lever is always operational from the inside and retracts latch. 3. Request to exit switch in lever to signal authorized egress to the access control system. 4. Door position switch to signal door open/closed to the access control system. Set: 29.0 Doors: 329A, 329B Description: Single Roll Call 3 Hinge, Full Mortise, Hvy Wt T4A3786 4-1/2" x 4-1/2" US26D MK 1 Passage Latch 8215 LNP US26D SA 1 Surface Closer 351 H EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 3 Silencer 608-RKW RO Set: 30.0 Doors: 203, 204, 205, 207, 208, 215, 231, 233, 234, 235, 303, 304, 305, 372, 373A, 373B, 374, 381, 382, 383, 384, 385, 386, 394, 395, 396, 397, 398 Description: Single Office 3 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2" US26D MK CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 32 1 Office Lock DG264 LB 8205 LNP US26D SA 1 Core DG2 6300 US15 SA 1 Wall Stop 406 US32D RO 3 Silencer 608-RKW RO Set: 31.0 Doors: 206, 222A, 224, 371 Description: Single Plan Room/ Conference/ Library 3 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2" US26D MK 1 Passage Latch 8215 LNP US26D SA 1 Wall Stop 406 US32D RO 3 Silencer 608-RKW RO Set: 32.0 Doors: 222B Description: Single Conference 3 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2" US26D MK 1 Passage Latch 8215 LNP US26D SA 1 Surf Overhead Stop 902_A US32D AH 3 Silencer 608-RKW RO Set: 33.0 Doors: 301B Description: Single Records 3 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2" US26D MK 1 Passage Latch 8215 LNP US26D SA 1 Surface Closer 351 O EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 3 Silencer 608-RKW RO Set: 34.0 Doors: 213A Description: Pair Kitchen 6 Hinge, Full Mortise, Hvy Wt T4A3786 4-1/2" x 4-1/2" US26D MK 2 Push Pull BF 110x73C/73CL Mtg-Type 9 US32D RO 2 Surface Closer 351 PH10 EN SA 2 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Astragal 18041CNB (Both Leaves) PE 2 Silencer 608-RKW RO Set: 35.0 Doors: 400A Description: Pair Corridor 6 Hinge, Full Mortise, Hvy Wt T4A3786 4-1/2" x 4-1/2" US26D MK 2 Push Pull BF 110x73C/73CL Mtg-Type 9 US32D RO CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 33 2 Surface Closer 351 P10 EN SA 2 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 2 Wall Stop 406 US32D RO 1 Astragal 18041CNB (Both Leaves) PE 2 Silencer 608-RKW RO Set: 36.0 Doors: 213B Description: Single Kitchen 3 Hinge, Full Mortise, Hvy Wt T4A3786 4-1/2" x 4-1/2" US26D MK 1 Push Pull BF 110x73C/73CL Mtg-Type 9 US32D RO 1 Surf Overhead Stop 902_A US32D AH 1 Surface Closer 351 O EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 3 Silencer 608-RKW RO Set: 37.0 Doors: 404A Description: Pair Armory Corridor 6 Hinge, Full Mortise, Hvy Wt T4A3786 4-1/2" x 4-1/2" US26D MK 2 Flush Bolt 555 US26D RO 1 Dust Proof Strike 570 US26D RO 1 Classroom Lock DG264 8237 LNP US26D SA 1 Core DG2 6300 US15 SA 2 Surf Overhead Stop 902_A US32D AH 2 Surface Closer 351 O EN SA 2 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Astragal 357SP PE 2 Silencer 608-RKW RO Notes: Mount astragal on push side of inactive leaf and size doors for 1/8" clearance between leaves. Paint astragal to match doors. Set: 38.0 Doors: 241 Description: Single Locker Room Glass 1 Pivot PV-WALKBEAM US32D GS 1 Bottom Pivot PV-ENDLOAD AL GS 2 Door Pull RM3301-18 Mtg-Type 13HD US32D RO 1 Concealed Closer OHC-609-90NHO GS Notes: Top and bottom rails by glass door manufacturer. Set: 39.0 Doors: 321, 321C, 322 Description: Single Restroom (ICC 500) 3 Hinge, Hvy Wt SP3786 4-1/2" x 4-1/2" US26D MK CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 34 1 Multi-Point Lock DG264 LB FM7325 LNP 188 US26D SA 1 Core DG2 6300 US15 SA 1 Surface Closer TB 281 O EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 1 Gasketing S773D PE Set: 40.0 Doors: 401 Description: Single Open Office (Future CR) 2 Hinge, Full Mortise, Hvy Wt T4A3786 4-1/2" x 4-1/2" US26D MK 1 Hinge, Full Mortise, Hvy Wt T4A3786 QC8 4-1/2" x 4-1/2" US26D MK 1 Office Lock DG264 LB 8205 LNP US26D SA 1 Core DG2 6300 US15 SA 1 Surface Closer 351 O EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 1 Gasketing S773D PE 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK Notes: Prep frame and door for future card access. Set: 41.0 Doors: EX-322D Description: Single Locker Rated (ICC 500, CR) 3 Hinge, Hvy Wt SP3786 4-1/2" x 4-1/2" US26D MK 1 Electrified Multi-Point Lock DG264 LB NAC-FM73281 LNP 188 US26D SA 1 Core DG2 6300 US15 SA 1 Surface Closer TB 281 O EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Door Stop 481H or 406 as Req'd US26D RO 1 Gasketing S773D PE 1 Electric Power Transfer EL-CEPT 630 SU 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK 1 Position Switch DPS-M or W as Req'd SU 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When outside lever is locked the card reader grants access upon presentation of a valid credential. Locksets mechanically lock during power failure with a mechanical key override entry. 2. Lever is always operational from the inside and retracts latch. 3. Request to exit switch in lever to signal authorized egress to the access control system. 4. Door position switch to signal door open/closed to the access control system. CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 35 Set: 42.0 Doors: 111, 113 Description: Single Restroom 3 Hinge, Full Mortise, Hvy Wt T4A3786 4-1/2" x 4-1/2" US26D MK 1 Push Pull BF 110x73C/73CL Mtg-Type 9 US32D RO 1 Surface Closer 351 O EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 3 Silencer 608-RKW RO Set: 43.0 Doors: 433 Description: Single Restroom 3 Hinge, Full Mortise, Hvy Wt T4A3786 4-1/2" x 4-1/2" US26D MK 1 Push Pull BF 110x73C/73CL Mtg-Type 9 US32D RO 1 Surface Closer 351 CPS EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 3 Silencer 608-RKW RO Set: 44.0 Doors: 112, 125, 232, 242, 243, 244, 245, 246A, 246B, 248, 311, 323, 324, 325, 399 Description: Single Toilet/ Wellness 3 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2" US26D MK 1 Privacy Lock LB V20 8265 LNP US26D SA 1 Surface Closer 351 O EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 3 Silencer 608-RKW RO Set: 45.0 Doors: 321A, 321B, 322A Description: Single Toilet 3 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2" US26D MK 1 Privacy Lock LB V20 8265 LNP US26D SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 3 Silencer 608-RKW RO Set: 46.0 Doors: 322B, 322C Description: Single Toilet 3 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2" US26D MK 1 Privacy Lock LB V20 8265 LNP US26D SA 1 Surf Overhead Stop 902_A US32D AH 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 3 Silencer 608-RKW RO CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 36 Set: 47.0 Doors: 312 Description: Single Custodial 3 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2" US26D MK 1 Passage Latch 8215 LNP US26D SA 1 Surface Closer 351 H EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 3 Silencer 608-RKW RO Set: 48.0 Doors: 247A, 247B Description: Single Decon 4 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2" US26D MK 1 Passage Latch 8215 LNP US26D SA 1 Surface Closer 351 O EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 1 Gasketing S88D PE 1 Door Bottom 369AA Z49-PL ZE Set: 48.1 (PR 07) Doors: 247B Description: Single Decon 4 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2" US26D MK 1 Classroom Lock DG264 8237 LNP US26D SA 1 Core DG2 6300 US15 SA 1 Surface Closer 351 O EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 1 Gasketing S88D PE 1 Door Bottom 369AA Z49-PL ZE Set: 49.0 Doors: 267 Description: Single Decon 3 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2" US26D MK 1 Passage Latch 8215 LNP US26D SA 1 Surface Closer 351 P10 EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 1 Gasketing S88D PE 1 Door Bottom 369AA Z49-PL ZE Set: 50.0 Doors: 250A, 250B, 250C, 250D, 250E, 250F, 250G, 250H, 250J, 250K CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 37 Description: Single Bunk Rated (STC) 3 Hinge, Full Mortise, Hvy Wt T4A3786 4-1/2" x 4-1/2" US26D MK 1 Privacy Lock LB V20 8265 LNP US26D SA 1 Surface Closer 351 O EN SA 1 Wall Stop 406 US32D RO Notes: Perimeter seals, door bottom, and threshold (if required) by acoustic door manufacturer. Set: 51.0 Doors: 266 Description: Single Turnout Room 4 Hinge, Full Mortise, Hvy Wt T4A3786 4-1/2" x 4-1/2" US26D MK 1 Classroom Lock DG264 8237 LNP US26D SA 1 Core DG2 6300 US15 SA 1 Surf Overhead Stop 902_A US32D AH 1 Surface Closer 351 O EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Threshold 171A PE 1 Gasketing 290AS (Head & Jambs) PE 1 Sweep 315CN PE Set: 52.0 Doors: 262A Description: Single EMS Storage 3 Hinge, Full Mortise, Hvy Wt T4A3786 5" x 4-1/2" US26D MK 1 Classroom Lock DG264 8237 LNP US26D SA 1 Core DG2 6300 US15 SA 1 Surface Closer 351 O EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 3 Silencer 608-RKW RO Set: 53.0 Doors: 262B Description: Single EMS Storage 4 Hinge, Full Mortise, Hvy Wt T4A3786 5" x 4-1/2" US26D MK 1 Classroom Lock DG264 8237 LNP US26D SA 1 Core DG2 6300 US15 SA 1 Surf Overhead Stop 902_A US32D AH 1 Surface Closer 351 O EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Threshold 171A PE 1 Gasketing 290AS (Head & Jambs) PE 1 Sweep 315CN PE Set: 54.0 Doors: 212 CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 38 Description: Single Training Storage 3 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2" US26D MK 1 Classroom Lock DG264 8237 LNP US26D SA 1 Core DG2 6300 US15 SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 3 Silencer 608-RKW RO Set: 55.0 Doors: 223, 307, 313, 353 Description: Single Corridor Storage 3 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2" US26D MK 1 Classroom Lock DG264 8237 LNP US26D SA 1 Core DG2 6300 US15 SA 1 Surface Closer 351 O EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 3 Silencer 608-RKW RO Set: 56.0 Doors: 270A, 271A Description: Single Mezz Storage 3 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2" US26D MK 1 Classroom Lock DG264 8237 LNP US26D SA 1 Core DG2 6300 US15 SA 1 Surface Closer 351 O EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 1 Threshold 171A PE 1 Sweep Custom Brush Sweep PE 3 Silencer 608-RKW RO Notes: Door to be undercut 6" to allow fire hose to pass under the door. Custom brush sweep required to close the 6" gap and allow the fire hose to pass under the door when in use. Set: 57.0 Doors: 271B, 280A Description: Pair Mezz Storage/ Water Entry 6 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2" US26D MK 2 Flush Bolt 555 US26D RO 1 Dust Proof Strike 570 US26D RO 1 Storeroom Lock DG264 8204 LNP US32D SA 1 Core DG2 6300 US15 SA 2 Surface Closer 351 PS EN SA 2 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Astragal 357SP PE 2 Silencer 608-RKW RO CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 39 Notes: Mount astragal on push side of inactive leaf and size doors for 1/8" clearance between leaves. Paint astragal to match doors. Set: 58.0 Doors: 403D Description: Pair Mezz Storage/ Water Entry 6 Hinge, Full Mortise, Hvy Wt T4A3786 5" x 4-1/2" US26D MK 2 Flush Bolt 555 US26D RO 1 Dust Proof Strike 570 US26D RO 1 Storeroom Lock DG264 8204 LNP US32D SA 1 Core DG2 6300 US15 SA 2 Surface Closer 351 PS EN SA 2 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Astragal 357SP PE 2 Silencer 608-RKW RO Notes: Mount astragal on push side of inactive leaf and size doors for 1/8" clearance between leaves. Paint astragal to match doors. Set: 59.0 Doors: 270B, 270C, 270D Description: Single Mezz Storage Panels 2 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2" US26D MK 1 Storeroom Lock DG264 8204 LNP US32D SA 1 Core DG2 6300 US15 SA 3 Silencer 608-RKW RO Set: 60.0 Doors: 122, 333 Description: Pair Fitness/ Training Storage 6 Hinge, Full Mortise, Hvy Wt T4A3786 NRP 4-1/2" x 4-1/2" US26D MK 2 Flush Bolt 555 US26D RO 1 Dust Proof Strike 570 US26D RO 1 Storeroom/Closet Lock DG264 8204 LNP 7/8" Lip Lgth US32D SA 1 Core DG2 6300 US15 SA 2 Surf Overhead Hold Open 901_A US32D AH 2 Armor Plate K1050 34" H x 2" LDW CSK BEV US32D RO 1 Astragal 357SP PE 2 Silencer 608-RKW RO Notes: Mount astragal on pull side of active leaf and size doors for 1/8” clearance between leaves. Paint astragal to match doors. Set: 61.0 Doors: 410 Description: Pair Articles (CR) CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 40 5 Hinge, Full Mortise, Hvy Wt T4A3786 4-1/2" x 4-1/2" US26D MK 1 Hinge, Full Mortise, Hvy Wt T4A3786 QC8 4-1/2" x 4-1/2" US26D MK 2 Flush Bolt 555 US26D RO 1 Dust Proof Strike 570 US26D RO 1 Fail Secure Lock DG264 RX 8271-24V LNP US26D SA 1 Core DG2 6300 US15 SA 2 Surf Overhead Stop 902_A US32D AH 2 Surface Closer 351 O EN SA 2 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Astragal 357SP PE 2 Silencer 608-RKW RO 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK 2 Position Switch DPS-M or W as Req'd SU 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Mount astragal on push side of inactive leaf and size doors for 1/8" clearance between leaves. Paint astragal to match doors. Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When outside lever is locked the card reader grants access upon presentation of a valid credential. Locksets mechanically lock during power failure with a mechanical key override entry. 2. Lever is always operational from the inside and retracts latch. 3. Request to exit switch in lever to signal authorized egress to the access control system. 4. Door position switch to signal door open/closed to the access control system. Set: 62.0 Doors: 123 Description: Pair Training Storage 6 Hinge, Full Mortise, Hvy Wt T4A3786 4-1/2" x 4-1/2" US26D MK 2 Flush Bolt 555 US26D RO 1 Dust Proof Strike 570 US26D RO 1 Classroom Lock DG264 8237 LNP US26D SA 1 Core DG2 6300 US15 SA 2 Surf Overhead Stop 902_A US32D AH 2 Surface Closer 351 O EN SA 2 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Astragal 357SP PE 2 Silencer 608-RKW RO Notes: Mount astragal on push side of inactive leaf and size doors for 1/8" clearance between leaves. Paint astragal to match doors. Set: 63.0 Doors: 423 Description: Pair Traffic Storage (CR) 5 Hinge, Full Mortise, Hvy Wt T4A3786 4-1/2" x 4-1/2" US26D MK CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 41 1 Hinge, Full Mortise, Hvy Wt T4A3786 QC8 4-1/2" x 4-1/2" US26D MK 2 Flush Bolt 555 US26D RO 1 Dust Proof Strike 570 US26D RO 1 Fail Secure Lock DG264 RX 8271-24V LNP US26D SA 1 Core DG2 6300 US15 SA 1 Surf Overhead Stop 902_A US32D AH 2 Surface Closer 351 O EN SA 2 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 1 Astragal 357SP PE 2 Silencer 608-RKW RO 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK 2 Position Switch DPS-M or W as Req'd SU 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Mount astragal on push side of inactive leaf and size doors for 1/8" clearance between leaves. Paint astragal to match doors. Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When outside lever is locked the card reader grants access upon presentation of a valid credential. Locksets mechanically lock during power failure with a mechanical key override entry. 2. Lever is always operational from the inside and retracts latch. 3. Request to exit switch in lever to signal authorized egress to the access control system. 4. Door position switch to signal door open/closed to the access control system. Set: 64.0 Doors: 251 Description: Pair Bifold Closet 6 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2" US26D MK 1 Complete Kit CF-415-4DRKIT KN 2 Pull 852 Mtg-Type 1 US32D RO Set: 65.0 Doors: 403A Description: Pair Mech 6 Hinge, Full Mortise, Hvy Wt T4A3786 NRP 4-1/2" x 4-1/2" US26D MK 2 Flush Bolt 555 US26D RO 1 Dust Proof Strike 570 US26D RO 1 Storeroom/Closet Lock DG264 8204 LNP 7/8" Lip Lgth US32D SA 1 Core DG2 6300 US15 SA 2 Surface Closer 351 P10 EN SA 2 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 2 Wall Stop 406 US32D RO 1 Astragal 357SP PE 2 Silencer 608-RKW RO CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 42 Notes: Mount astragal on pull side of active leaf and size doors for 1/8” clearance between leaves. Paint astragal to match doors. Set: 66.0 Doors: 450A Description: Single Shell Space (CR) 2 Hinge, Full Mortise, Hvy Wt T4A3786 NRP 4-1/2" x 4-1/2" US26D MK 1 Hinge, Full Mortise, Hvy Wt T4A3786 QC8 4-1/2" x 4-1/2" US26D MK 1 Fail Secure Lock DG264 RX 8271-24V LNP US26D SA 1 Core DG2 6300 US15 SA 1 Surface Closer 351 P10 EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 3 Silencer 608-RKW RO 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK 1 Position Switch DPS-M or W as Req'd SU 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When outside lever is locked the card reader grants access upon presentation of a valid credential. Locksets mechanically lock during power failure with a mechanical key override entry. 2. Lever is always operational from the inside and retracts latch. 3. Request to exit switch in lever to signal authorized egress to the access control system. 4. Door position switch to signal door open/closed to the access control system. Set: 67.0 Doors: 450B Description: Pair Shell Space (CR) 5 Hinge, Full Mortise, Hvy Wt T4A3786 NRP 4-1/2" x 4-1/2" US26D MK 1 Hinge, Full Mortise, Hvy Wt T4A3786 QC8 4-1/2" x 4-1/2" US26D MK 2 Flush Bolt 555 US26D RO 1 Dust Proof Strike 570 US26D RO 1 Fail Secure Lock DG264 RX 8271-24V LNP 7/8" Lip Lgth US26D SA 1 Core DG2 6300 US15 SA 2 Surface Closer 351 CPS EN SA 2 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Astragal 357SP PE 3 Silencer 608-RKW RO 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK 2 Position Switch DPS-M or W as Req'd SU 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 43 Notes: Mount astragal on pull side of active leaf and size doors for 1/8” clearance between leaves. Paint astragal to match doors. Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When outside lever is locked the card reader grants access upon presentation of a valid credential. Locksets mechanically lock during power failure with a mechanical key override entry. 2. Lever is always operational from the inside and retracts latch. 3. Request to exit switch in lever to signal authorized egress to the access control system. 4. Door position switch to signal door open/closed to the access control system. Set: 68.0 Doors: 281, 342, 408 Description: Single IT Rated/ AV/ IDF (CR) 2 Hinge, Full Mortise, Hvy Wt T4A3786 4-1/2" x 4-1/2" US26D MK 1 Hinge, Full Mortise, Hvy Wt T4A3786 QC8 4-1/2" x 4-1/2" US26D MK 1 Fail Secure Lock DG264 RX 8271-24V LNP US26D SA 1 Core DG2 6300 US15 SA 1 Surface Closer 351 O EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 1 Threshold 171A PE 1 Gasketing S88D PE 1 Sweep 315CN PE 1 ElectroLynx Harness QC-C Series (Frame) MK 1 ElectroLynx Harness QC-C Series (Door) MK 1 Position Switch DPS-M or W as Req'd SU 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA Notes: Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When outside lever is locked the card reader grants access upon presentation of a valid credential. Locksets mechanically lock during power failure with a mechanical key override entry. 2. Lever is always operational from the inside and retracts latch. 3. Request to exit switch in lever to signal authorized egress to the access control system. 4. Door position switch to signal door open/closed to the access control system. Set: 69.0 Doors: 409 Description: Pair Electrical Rated 8 Hinge, Full Mortise, Hvy Wt T4A3786 NRP 5" x 4-1/2" US26D MK 1 Mullion L980S PC SA 1 Rim Exit Device, Storeroom DG264 12 PE8804 WEP US32D SA 1 Rim Exit Device, Exit Only 12 PE8510 EO US32D SA 2 Core DG2 6300 US15 SA 1 Cylinder DG264 980C1 US26D SA 2 Surface Closer 351 P10 EN SA CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 44 2 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 2 Wall Stop 406 US32D RO 1 Gasketing S88D PE 1 Mullion Gasketing 5110BL PE Set: 70.0 Doors: 403B Description: Single Electrical 3 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2" US26D MK 1 Rim Exit Device, Passage PE8815 WEP US32D SA 1 Surface Closer 351 P10 EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 1 Gasketing S88D PE Set: 71.0 Doors: 236 Description: Single Electrical 3 Hinge, Full Mortise TA2714 NRP 4-1/2" x 4-1/2" US26D MK 1 Rim Exit Device, Storeroom DG264 PE8804 WEP US32D SA 1 Core DG2 6300 US15 SA 1 Surface Closer 351 CPS EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Gasketing S88D PE Set: 72.0 Doors: 261 Description: Single Water 4 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2" US26D MK 1 Storeroom Lock DG264 8204 LNP US32D SA 1 Core DG2 6300 US15 SA 1 Surface Closer 351 O EN SA 1 Kick Plate K1050 10" H x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US32D RO 3 Silencer 608-RKW RO Set: 73.0 Doors: 104C Description: Pair Kitchenette Bi Parting 1 Bi Parting Door Kit CRT-101-CC x width as req'd SS KN 4 Door Pull RM3301-24 Mtg-Type 5HD US32D RO Set: 74.0 Doors: 272 Description: Single Mech Chain Link (CR) 1 Gate Lock GL1-FLM SU CITY OF WAUKEE OPN PROJECT NO. 21841001 WAUKEE PUBLIC SAFETY BUILDING PR 07 DOOR HARDWARE 08 71 00 - 45 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA 1 Bracket FMK-SW SU Notes: Balance of hardware including hinges and closer by gate supplier. Gates to be prepped and reinforced to accept hardware. Prior to ordering hardware or fabricating gates, coordinate to ensure hardware is compatible with gate system. Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When gates are locked then the card reader grants access upon presentation of a valid credential. Set: 75.0 Doors: 273, 404B, 406 Description: Pair Mech/ Armory Chain Link (CR) 1 Locking Cane Bolt LB118BX x LBBPGB Black DD 1 Gate Lock GL1-FLM SU 1 Card Reader By ACS Provider OT 1 Power Supply By ACS Provider YA 1 Bracket FMK-SW SU Notes: Balance of hardware including hinges and closer by gate supplier. Gates to be prepped and reinforced to accept hardware. Prior to ordering hardware or fabricating gates, coordinate to ensure hardware is compatible with gate system. Operation: 1. Doors electrically unlocked or locked during established time zones as programmed by the access control system. When gates are locked then the card reader grants access upon presentation of a valid credential. Set: 76.0 Doors: OH-01, OH-02, OH-03, OH-04, OH-05, OH-06, OH-07, OH-08, OH-09, OH-10, OH-11, OH-12, OH-13 Description: Overhead Door Notes: All hardware by door manufacturer. END OF SECTION GENERAL NOTES 1. SEE FRAME PLANS AND INTERIOR ELEVATIONS FOR DIMENSIONAL SIZES WITH MATERIALS OF FRAMES. 2. PREPARE DOOR AND FRAME FOR PAINT - BONDO DENTS AND SAND SCRATCHES SMOOTH. 3. REFER TO A002 FOR INTERIOR PARTITION TYPES FOR FRAME THROAT DEPTH REQUIREMENTS 4. ALL FRAMES SET IN INTERIOR PRECAST OR CMU WALLS ARE TO MATCH WALL THICKNESS SCHEDULE SEE SC H E D U L E SE E F SCHEDULE SEE SC H E D U L E SE E SC H E D U L E SE E SCHEDULE SEE 6"6" 3' - 6 " 2' - 6 " SC H E D U L E SE E 1' - 0 " 7 3 / 4 " SCHEDULE SEE 6"6" SC H E D U L E SE E SCHEDULE SEE SC H E D U L E SE E SCHEDULE SEE SC H E D U L E SE E SCHEDULE SEE SC H E D U L E SE E SCHEDULE SEE SC H E D U L E SE E SCHEDULE SEE G N FG BF SC H E D U L E SE E 10 " 4" SCHEDULE SEE 4"4" MS FOUR-FOLD DOOR SECTIONAL DOOR APPARATUS BAY SECTIONAL DOOR FITNESS SECTIONAL DOOR POLICE GARAGE SO L I D G L A S S SO L I D G L A S S SC H E D U L E SE E 3' - 6 " 6" SCHEDULE SEE 6"6" HG G1*G1* IG-1*G1* G1* IG-1* SO L I D G L A S S 01 SC H E D U L E SE E 2" SCHEDULE SEE 2" 2" 02 SC H E D U L E SE E 2" SCHEDULE SEE 2" 4" SC H E D U L E SE E 2" 2" SCHEDULE SEE 2" 1'-6" 2" 4" SC H E D U L E SE E 2 " 2" SCHEDULE SEE 2" 2'-10" 2" 4" 03 04 05 SC H E D U L E SE E 2 ' - 1 0 " 2 " 2" SCHEDULE SEE 2" G1*IG-1* 06 SC H E D U L E SE E 2" SCHEDULE SEE 2" 2" AF F SE E M13 A801 M22 A801 M13 A801 M22 A801 M13 A801 M22 A801 M22 A801 A13 A801 A22 A801 G22 A801 G13 A801 G22 A801 G13 A801 STATIONARY TRANSOM -SET FLUSH WITH DOOR BELOW M13 A801 T13 A801 SF/CW SF: ALUMINUM STOREFRONT FRAME CW: ALUMINUM CURTAIN WALL FRAME SCHEDULE REMARKS 1. CARD READER - SEE TELECOM 2. STORM SHELTER DOOR COMPLYING WITH ICC 500 3. STC DOOR 4. ADA DOOR OPERATOR 5. PRIVACY FILM ON GLASS 6. HARDENED SECURITY DOOR 7. ONE-WAY MIRROR FILM ON GLASS 8. PAINT FRAME AND DOOR TO MATCH WALL 9. 6" UNDERCUT WITH SWEEP 10. ROUGH-IN FOR FUTURE CARD READER INTERIOR GLAZING LEGEND NON-INSULATED VISION GLAZINGG1 G3 NON-INSULATED BALLISTICS RATED GLAZING NOTE: (*) -DENOTES TEMPERED GLAZING, TYP. SEE SPECIFICATION FOR GLAZING THICKNESS REQUIREMENTS INTERIOR GLAZING IS TYPE G-1*, U.N.O. NON-INSULATED BACK-PAINTED GLAZINGG2 G4 NON-INSULATED LAMINATED GLAZING WITH COLORED PLASTIC INTERLAYER EXTERIOR GLAZING LEGEND 1" INSULATED VISION GLAZINGIG-1 IG-2 1" INSULATED SPANDREL GLAZING MP METAL PANEL W/ INSULATED BACKPAN IBP INSULATED BACKPAN NOTE: (*) -DENOTES TEMPERED GLAZING, TYP. A 19181716151413121110987654 B C D E F G H J K L M N P Q PR I N T E D : R S T U 20 21 22 23 24 25 Sheet Name Key Plan 321 19181716151413121110987654 20 21 22 23 24 25321 Sheet Number Sheet Issue Date OPN Project No. 26 26 27 27 28 28 29 29 V W X Y Owner All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc. shall retain all common law, statutory and other reserved rights, including the copyright thereto. © 2022 OPN Architects, Inc. 100 Court Ave., Suite 100 Des Moines, IA 50309 P: 515-309-0722 www.opnarchitects.com RYAN COMPANIES 111 E GRAND AVENUE, SUITE 200 DES MOINES, IA 50309 P. 515-309-8500 Project Construction Manager FOTH 8191 BIRCHWOOD COURT, SUITE L JOHNSTON, IA 50131 P. 515-254-1393 Civil Engineer RAKER RHODES ENGINEERING 4717 GRAND AVENUE DES MOINES, IA 50313 P. 515-277-0275 Structural Engineer MORRISSEY ENGINEERING 4940 NORTH 118TH STREET OMAHA, NE 68164 P. 402-491-4144 MEPT Engineer CONFLUENCE 525 17TH STREET DES MOINES, IA 50309 P. 515-288-4875 Landscape Architect A B C 5/ 2 / 2 0 2 4 9 : 3 4 : 2 2 A M A800 DOOR SCHEDULE 21841001 CONSTRUCTION SET 11/21/2023 WAUKEE PUBLIC SAFETY BUILDING 815 NW 20th STREET WAUKEE, IA 50263 CITY OF WAUKEE 230 W. HICKMAN ROAD WAUKEE, IA 50263 DOOR SCHEDULE DOOR NUMBER PANEL FRAME Fire Rating REMARKS HARDWARE SET PANEL QUANTITY PANEL TYPE WIDTH HEIGHT PANEL 1 WIDTH PANEL 2 WIDTH PANEL MATERIAL PANEL FINISH FRAME TYPE MATERIAL FINISH 100A 2 MS 6'-4" 9'-2 1/2" 3'-2" 3'-2" ALUM ANOD CW ALUM ANOD 1,4 9.0 102A 1 MS 3'-0" 9'-10" 3'-0" ALUM ANOD SF ALUM ANOD 1 14.0 102B 2 MS 6'-6" 9'-10" 3'-3" 3'-3" ALUM ANOD SF ALUM ANOD 1 15.0 102C 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 1 19.0 102D 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 1 20.0 104A 1 F 3'-0" 7'-0" 3'-0" WD STN 05 HM PNT 1 28.0 104B 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 27.0 104C 2 8'-0" 6'-10 5/8" 4'-0" 4'-0" WD STN None None COUNTER 73.0 110 1 F 3'-0" 7'-0" 3'-0" WD STN 05 HM PNT 1 24.0 111 1 F 3'-0" 7'-0" 3'-0" WD STN 05 HM PNT 42.0 112 1 F 3'-0" 7'-0" 3'-0" WD STN 05 HM PNT 44.0 113 1 F 3'-0" 7'-0" 3'-0" WD STN 05 HM PNT 42.0 114 1 F 3'-0" 7'-0" 3'-0" WD STN 05 HM PNT 1 25.0 115 1 F 3'-0" 7'-0" 3'-0" WD STN 05 HM PNT 1 25.0 116 1 F 3'-0" 7'-0" 3'-0" WD STN 05 HM PNT 1 25.0 121A 1 MS 3'-0" 7'-0" 3'-0" ALUM ANOD SF ALUM ANOD 1 22.0 121B 1 MS 3'-0" 7'-0" 3'-0" ALUM ANOD SF ALUM ANOD 1 23.0 122 2 F 6'-0" 7'-0" 3'-0" 3'-0" HM PNT 01 HM PNT 8 60.0 123 2 F 6'-0" 7'-0" 3'-0" 3'-0" HM PNT 01 HM PNT 8 62.0 124 1 F 3'-0" 7'-0" 3'-0" HM PNT 01 HM PNT 8 12.0 125 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 44.0 201 1 F 3'-0" 7'-0" 3'-0" WD STN 05 HM PNT 1 24.0 203 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 30.0 204 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 30.0 205 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 30.0 206 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 31.0 207 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 30.0 208 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 30.0 211A 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 16.0 211B 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 16.0 212 1 F 3'-0" 7'-0" 3'-0" HM PNT 01 HM PNT 8 54.0 213A 2 FG 6'-0" 7'-0" 3'-0" 3'-0" WD STN 01 HM PNT 34.0 213B 1 FG 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 36.0 215 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 30.0 222A 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 31.0 222B 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 32.0 223 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 55.0 224 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 31.0 230 1 HG 3'-0" 7'-10" 3'-0" HM PNT 04 HM PNT 13.0 231 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 30.0 232 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 44.0 233 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 30.0 234 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 30.0 235 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 30.0 236 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 71.0 240 1 HG 3'-0" 7'-10" 3'-0" HM PNT 04 HM PNT 13.0 241 1 G 3'-0" 7'-2" 3'-0" GL GL SF GL GL 38.0 242 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 44.0 243 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 44.0 244 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 44.0 245 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 44.0 246A 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 44.0 246B 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 44.0 247A 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 48.0 247B 1 N 3'-0" 7'-8" 3'-0" HM PNT 02 HM PNT 48.1 248 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 44.0 250A 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 20 3 50.0 250B 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 20 3 50.0 250C 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 20 3 50.0 250D 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 20 3 50.0 250E 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 20 3 50.0 250F 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 20 3 50.0 250G 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 20 3 50.0 250H 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 20 3 50.0 250J 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 20 3 50.0 250K 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 20 3 50.0 251 BF 5'-0" 7'-0" WD STN HM PNT CLOSET 64.0 261 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 72.0 262A 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 52.0 262B 1 N 3'-6" 7'-8" 3'-6" HM PNT 02 HM PNT 53.0 266 1 F 3'-0" 7'-8" 3'-0" HM PNT 02 HM PNT 51.0 267 1 F 3'-0" 7'-0" 3'-0" HM PNT 02 HM PNT 49.0 270A 1 F 3'-0" 7'-0" 3'-0" HM PNT 02 HM PNT 9 56.0 270B 1 F 2'-0" 3'-2" 2'-0" HM PNT 06 HM PNT 8 59.0 270C 1 F 3'-0" 4'-2" 3'-0" HM PNT 06 HM PNT 8 59.0 270D 1 F 4'-0" 4'-2" 4'-0" HM PNT 06 HM PNT 8 59.0 271A 1 F 3'-0" 7'-0" 3'-0" HM PNT 02 HM PNT 9 56.0 271B 2 F 6'-0" 7'-0" 3'-0" 3'-0" HM PNT 02 HM PNT 8 57.0 272 1 - 3'-0" 7'-0" 3'-0" - - - - - CHAIN LINK 74.0 273 2 - 6'-0" 7'-0" 3'-0" 3'-0" - - - - - 1, CHAIN LINK 75.0 280 1 F 3'-0" 7'-0" 3'-0" HM PNT 01 HM PNT 12.0 280A 2 F 6'-0" 7'-0" 3'-0" 3'-0" HM PNT 02 HM PNT 8 57.0 281 1 F 3'-0" 7'-0" 3'-0" HM PNT 01 HM PNT 90 1 68.0 301A 1 F 3'-0" 7'-0" 3'-0" WD STN 05 HM PNT 1 17.0 301B 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 33.0 303 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 5 30.0 304 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 5 30.0 305 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 5 30.0 306 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 1 19.0 307 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 1 19.0 311 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 44.0 312 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 47.0 313 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 55.0 321 1 F 3'-0" 7'-0" 3'-0" HM PNT 02 HM PNT 90 2 39.0 321A 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 45.0 321B 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 45.0 321C 1 F 3'-0" 7'-0" 3'-0" HM PNT 02 HM PNT 90 2 39.0 322 1 F 3'-0" 7'-0" 3'-0" HM PNT 02 HM PNT 90 2 39.0 322A 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 45.0 322B 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 46.0 322C 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 46.0 323 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 44.0 324 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 44.0 325 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 44.0 329A 1 N 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 29.0 329B 1 N 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 29.0 331A 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 1,5 19.0 331B 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 1,5 19.0 332A 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 1,5 19.0 332B 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 1,5 19.0 333 2 F 6'-0" 7'-0" 3'-0" 3'-0" HM PNT 01 HM PNT 8 60.0 341 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 12.0 342 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 90 1 68.0 DOOR PANEL TYPES DOOR FRAME ELEVATIONS DOOR SCHEDULE DOOR NUMBER PANEL FRAME Fire Rating REMARKS HARDWARE SET PANEL QUANTITY PANEL TYPE WIDTH HEIGHT PANEL 1 WIDTH PANEL 2 WIDTH PANEL MATERIAL PANEL FINISH FRAME TYPE MATERIAL FINISH 353 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 55.0 354 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 1 19.0 364 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 1 20.0 365 1 F 3'-0" 7'-0" 3'-0" HM PNT 01 HM PNT 1 21.0 366A 1 F 3'-0" 7'-0" 3'-0" HM PNT 01 HM PNT 1 19.0 366B 1 F 3'-0" 7'-0" 3'-0" HM PNT 01 HM PNT 1 20.0 367 1 F 3'-0" 7'-0" 3'-0" HM PNT 01 HM PNT 1 19.0 368 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 1 19.0 371 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 5 31.0 372 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 5 30.0 373A 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 5 30.0 373B 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 30.0 374 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 5 30.0 381 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 5 30.0 382 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 5 30.0 383 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 5 30.0 384 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 5 30.0 385 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 5 30.0 386 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 5 30.0 390A 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 1,5 19.0 390B 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 1,5 19.0 391A 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 1,5 19.0 391B 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 1,5 19.0 392 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 1 19.0 393 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 1 19.0 394 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 5 30.0 395 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 5 30.0 396 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 5 30.0 397 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 5 30.0 398 1 F 3'-0" 7'-0" 3'-0" WD STN 03 HM PNT 5 30.0 399 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 44.0 400A 2 N 6'-0" 7'-0" 3'-0" 3'-0" HM PNT 01 HM PNT 35.0 400B 2 N 6'-4" 9'-0" 3'-2" 3'-2" HM PNT 02 HM PNT 1 10.0 401 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 10 40.0 403A 2 F 6'-4" 7'-0" 3'-2" 3'-2" HM PNT 02 HM PNT 65.0 403B 1 F 3'-0" 7'-0" 3'-0" HM PNT 02 HM PNT 70.0 403D 2 F 6'-4" 7'-0" 3'-2" 3'-2" HM PNT 02 HM PNT 58.0 404A 2 F 6'-4" 7'-0" 3'-2" 3'-2" HM PNT 02 HM PNT 37.0 404B 2 - 6'-0" 7'-0" 3'-0" 3'-0" - - - - - 1, CHAIN LINK 75.0 406 2 - 6'-0" 7'-0" 3'-0" 3'-0" - - - - - 1, CHAIN LINK 75.0 408 1 F 3'-0" 7'-0" 3'-0" HM PNT 02 HM PNT 90 1 68.0 409 2 F 6'-4" 9'-0" 3'-2" 3'-2" HM PNT 02 HM PNT 69.0 410 2 F 6'-4" 7'-0" 3'-2" 3'-2" HM PNT 02 HM PNT 1 61.0 421 1 F 3'-0" 7'-0" 3'-0" HM PNT 02 HM PNT 1 19.0 423 2 F 6'-4" 7'-0" 3'-2" 3'-2" HM PNT 02 HM PNT 1 63.0 431A 1 N 3'-0" 7'-0" 3'-0" HM PNT 02 HM PNT 1,6,7 11.0 431B 1 N 3'-0" 7'-0" 3'-0" HM PNT 02 HM PNT 1,6,7 18.0 431C 1 N 3'-0" 7'-0" 3'-0" HM PNT 02 HM PNT 1,6,7 19.0 432 1 N 3'-0" 7'-0" 3'-0" HM PNT 02 HM PNT 1,6,7 26.0 433 1 F 3'-0" 7'-0" 3'-0" HM PNT 02 HM PNT 6 43.0 434 1 N 3'-0" 7'-0" 3'-0" HM PNT 02 HM PNT 1,6,7 26.0 435 1 N 3'-0" 7'-0" 3'-0" HM PNT 02 HM PNT 1,6,7 26.0 450A 1 F 3'-0" 7'-0" 3'-0" WD STN 01 HM PNT 1 66.0 450B 2 N 6'-0" 7'-0" 3'-0" 3'-0" HM PNT 02 HM PNT 1 67.0 DOOR SCHEDULE - EXTERIOR DOOR NUMBER PANEL FRAME Fire Rating REMARKS HARDWARE SET PANEL QUANTITY PANEL TYPE WIDTH HEIGHT PANEL 1 WIDTH PANEL 2 WIDTH PANEL MATERIAL PANEL FINISH FRAME TYPE MATERIAL FINISH EX-100 2 MS 6'-4 3/4" 9'-3 1/8" 3'-2" 3'-2" ALUM ANOD CW ALUM ANOD 1,4 1.0 EX-101A 1 MS 3'-0" 9'-8 3/4" 3'-0" ALUM ANOD CW ALUM ANOD 4.0 EX-101B 1 MS 3'-0" 9'-8 3/4" 3'-0" ALUM ANOD CW ALUM ANOD 4.0 EX-121C 1 MS 3'-0" 9'-8 1/4" 3'-0" ALUM ANOD CW ALUM ANOD 4.0 EX-121D 1 MS 3'-0" 9'-8 1/4" 3'-0" ALUM ANOD CW ALUM ANOD 1 3.0 EX-214 1 MS 3'-6" 9'-9 1/2" 3'-0" ALUM ANOD CW ALUM ANOD 1 3.0 EX-221 1 MS 3'-0" 9'-8 3/4" 3'-0" ALUM ANOD CW ALUM ANOD 1 3.0 EX-268 1 F 3'-2" 7'-0" 3'-2" HM PNT 02 HM PNT 1, PT-7 5.0 EX-269 1 MS 3'-5" 8'-0" 3'-5" ALUM ANOD CW ALUM ANOD 1 3.0 EX-280B 1 F 3'-0" 5'-8" 3'-0" HM PNT 06 HM PNT PT-7 7.0 EX-322D 1 F 3'-0" 7'-0" 3'-0" HM PNT 02 HM PNT 90 1, 2, PT-6 41.0 EX-326 1 MS 3'-0" 9'-8 3/4" 3'-0" ALUM ANOD CW ALUM ANOD 1 3.0 EX-361 2 MS 6'-0" 9'-8 3/4" 3'-2" 3'-2" ALUM ANOD CW ALUM ANOD 1 2.0 EX-403C 2 F 7'-0" 8'-0" 3'-6" 3'-6" HM PNT 02 HM PNT PT-6 8.0 EX-420A 1 F 3'-2" 7'-0" 3'-2" HM PNT 02 HM PNT 1, PT-6 5.0 EX-420B 1 F 3'-2" 7'-0" 3'-2" HM PNT 02 HM PNT 1, PT-6 5.0 EX-430 1 F 3'-2" 7'-0" 3'-2" HM PNT 02 HM PNT 1, PT-6 6.0 DOOR SCHEDULE - OVERHEAD DOOR NUMBER PANEL Fire Rating REMARKS HARDWARE SETWIDTH HEIGHT PANEL MATERIAL PANEL FINISH OH-01 14'-0" 14'-0" PT-7 FOUR-FOLD GLAZED 76.0 OH-02 14'-0" 14'-0" PT-7 FOUR-FOLD GLAZED 76.0 OH-03 14'-0" 14'-0" PT-7 FOUR-FOLD GLAZED 76.0 OH-04 14'-0" 14'-0" PT-7 FOUR-FOLD GLAZED 76.0 OH-05 14'-0" 14'-0" PT-7 ALUMINUM GLAZED SECTIONAL HIGH LIFT 76.0 OH-06 14'-0" 14'-0" PT-7 ALUMINUM GLAZED SECTIONAL HIGH LIFT 76.0 OH-07 14'-0" 14'-0" PT-7 ALUMINUM GLAZED SECTIONAL HIGH LIFT 76.0 OH-08 14'-0" 14'-0" PT-7 ALUMINUM GLAZED SECTIONAL HIGH LIFT 76.0 OH-09 13'-4" 10'-0" PT-7 ALUMINUM GLAZED SECTIONAL VERTICAL LIFT 76.0 OH-10 10'-0" 10'-0" PT-7 STEEL SECTIONAL, CHAIN DRIVE OPENER 76.0 OH-11 13'-4" 12'-0" PT-7 STEEL SECTIONAL, LOW HEADROOM TRACK 76.0 OH-12 13'-4" 12'-0" PT-7 STEEL SECTIONAL 76.0 OH-13 13'-4" 12'-0" PT-7 STEEL SECTIONAL 76.0 NOTE: WIDTH AND HEIGHT FOR OVERHEAD DOORS INDICATES ROUGH OPENING SIZE. CONFIRM ACTUAL DOOR DIMENSIONS REQUIRED WITH DETAILS. Revision Description Date ADD 02 Addendum 10/31/23 PR 07 PR 5/2/2024 ADD 02 PR 07 PR 07 Waukee Public Safety - Change Request Summary 5/23/2024 Ryan Companies US, Inc. Change Request Subcontractor Comments Cost Change 22.0 DDVI Revise hardware sets to reflect PR-07 direction. Material only cost impact. $1,573.88 22.1 Jordison Construction No response $0.00 22.2 Enterprise Precast No response $0.00 22.3 TSF Structures No response $0.00 22.4 Northwest Steel No response $0.00 22.5 Forman Ford No response $0.00 22.6 Academy Roofing No response $0.00 22.7 Ford Metro No response $0.00 22.8 Skold Door No response $0.00 22.9 Hilsabeck Schacht No response $0.00 22.10 Elite Fire Sprinkler No response $0.00 22.11 Kruck Plumbing and Heating No response $0.00 22.12 Van Maanen No response $0.00 22.13 TriCity Electric No response $0.00 22.14 Wenthold No response $0.00 22.15 Absolute No response $0.00 22.16 Jordison Construction No response $0.00 22.17 Alpha Landscapes No response $0.00 $1,573.88 Builders Risk (.23% Cost of Work (Estimated)) Excluded per City $0.00 CMa Fee on Cost of Work (3.25%)$51.15 CMa Project Manager Time $0.00 CMa Project Superintendent Time $0.00 $1,625.03 Change Request 022 Summary: PR-07, door hardware revisions due to clarifications requested by DDVI/Walsh during the shop drawing review process. Change Request 022 Subtotal Change Request 022 Cost Change Total May 7, 2024 CR#022 Waukee Public Safety Building Job #6173-000 DDVI – General Construction Hilsabeck Schacht - Framing, Drywall & Ceilings Jordison Construction – Building Concrete Elite Fire Sprinkler – Fire Protection Enterprise Precast – Precast Material Kruck Plumbing and Heating - Mechanical & Plumbing TSF Structures - Steel Material & Misc. Metals Van Maanen Electric – Electrical & Communications Northwest Steel - Precast & Steel Erection TriCity Electric – Audio-Visual Forman Ford – Metal Panels Wenthold Excavating – Earthwork & Utilities Academy Roofing – Roofing Absolute Group - SWPPP Ford Metro – Glass & Glazing Jordison Construction – Site Concrete Skold Door – Overhead Doors Alpha Landscapes – Landscape & Irrigation Dear Prime Contractors: We are forwarding this Change Request, briefly described as follows, for your review and response: PR-07 includes the following revisions: Revisions to door hardware based on shop drawing review and owner feedback. This Change Request is further defined by the following attached documents: Drawings: A800 Spec Sections: 08 71 00 Please mark the appropriate “Status” below, sign and re turn one copy of this Change Request to Ryan Companies US, Inc. no later than 05/15/2024. Attach a detailed proposal itemizing any cost or schedule impacts resulting from this change. Include reference to this Change Request, quantities (add or deduct), unit prices for labor and materials, and the latest date the proposal may be accepted. A lack of response by the date required above will indicate no change to your Prime Contract Agreement. Your timely response to the Change Request will be appreciated. Please call if you have any questions, or if you need additional information. DO NOT PROCEED; SUBMIT QUOTATION ONLY PROCEED WITH WORK PROCEED WITH WORK NOT TO EXCEED $ AND SUBMIT QUOTATION PROCEED WITH WORK; NO ADDITIONAL COST ANTICIPATED PROCEED WITH WORK; SUBMIT QUOTATION OTHER Sincerely, Acknowledged: RYAN COMPANIES US, INC. By: Company: Date: Status: Proposal attached Jill Boetger No impact on cost or schedule Project Manager II More information or discussion required DDVI, Inc. 5/22/24