Loading...
HomeMy WebLinkAbout2024-10-07 I05 Cove at Kettlestone Plat 4, Lot 2_Site Plan AGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: October 7, 2024 AGENDA ITEM: Consideration of approval of resolutions approving a site plan for Cove at Kettlestone Plat 4, Lot 2 (1475 SE Bishop Drive) FORMAT: Resolutions SYNOPSIS INCLUDING PRO & CON: The applicant is requesting approval of a site plan for a grocery store, located south of SE University Avenue and west of SE Waco Place, containing 1.62-acres. The project includes the construction of a single-story building for a grocery store. The building is 6,000 square feet in area and 28 feet in height. A trash enclosure is provided at the northwest corner of the site. Two accesses will be provided into this site, one off of the shared private drive to the north and one off of SE Bishop Drive at the south. A ten-foot- wide trail will be provided along SE Waco Place and a five-foot-wide sidewalk will be provided along SE Bishop Drive adjacent to the site. A total of 24 parking spaces are required, they are providing 38 spaces. The site will be serviced with all public utilities. Stormwater detention will be provided with a detention basin located at the west side of the site and with underground detention located at the southeast corner of the site. A minimum of 15% of the site is required to be open space, they are providing 35%. The required amount of plantings are being provided. The elevations of the building will be constructed of stone, brick, storefront system, and Nichiha siding. The trash enclosure will be composed of brick with metal gates. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning Commission reviewed the site plan request at their meeting on September 24, 2024, and recommended approval: Approval of a Site Plan for Cove at Kettlestone Plat 4, Lot 2 (1475 SE Bishop Drive) Melissa DeBoer, Planning Coordinator, introduced the request for approval of a site plan for a grocery store, as requested by Super 6, LLC, represented by Korey Marsh, of Snyder & Associates, Inc. The property is generally located south of SE University Avenue and west of SE Waco Place, containing approximately 1.62-acres, within the Cove at Kettlestone development. The property is a vacant lot, platted as Lot 2, Cove at Kettlestone Plat 4. I5 The project includes construction of a single-story building for a grocery store that includes a small restaurant space within the grocery store. The building is 6,000 square feet in area and 28 feet in height. The main entrance to the building is located on the north side of the building. A small patio is proposed on the east side of the building. The site plan includes a trash enclosure located at the northwest corner of the site and a monument sign located at the northeast corner of the site, adjacent to SE Waco Place. The site plan also shows a potential future addition which includes a 4,000 square foot building addition, additional parking spaces and continuation of the drive aisles to provide continued access around the site and building. A future addition will require separate site plan approval. There are two accesses into this site. One is located at the northwest corner from the shared private drive, and one is located at the southwest corner from SE Bishop Drive. A total of 24 parking spaces are required for this project, with a total amount of 38 spaces proposed, including (2) two accessible stalls. The site plan also identifies a bicycle rack located to the northwest of the building that includes (2) two bicycle parking spaces to meet the Kettlestone Design Guidelines. The proposed site plan meets the parking requirements. Additionally, the site plan also indicates areas at the east sides of the site for future parking, including the possibility of an additional 15 future parking stalls. A ten-foot-wide trail will be installed along SE Waco Place and a five-foot-wide sidewalk will be installed along SE Bishop Drive adjacent to the site. A pedestrian connection is provided into the site from the public sidewalk along SE Bishop Drive. Sidewalks are proposed interior to the site to provide pedestrian connections from the parking lot to the proposed building, and around the building. The site will be serviced with all public utilities. Water and sanitary sewer will be brought from mains located to the south along SE Bishop Drive. Storm water detention will be provided with a detention basin located at the west side of the site and with underground detention located at the southeast corner of the site. A minimum of 15% of the project area is required to be open space, with the amount proposed at 35%. The landscape plan meets the requirements of the Landscape and Open Space Ordinance and the Kettlestone Design Guidelines. The elevations of the building are proposed to be constructed mostly of stone, brick, storefront system, and Nichiha siding. The trash enclosure is proposed to be constructed of brick with metal gates. The applicant has submitted a photometric plan and associated light fixture cut sheets which meets the lighting requirements of the Site Plan Ordinance. The comprehensive plan classifies the subject property as Community Commercial. This classification provides a variety of uses that would serve the community and are located along minor or major arterials. The site plan is in general conformance with the Site Plan Ordinance, Comprehensive Plan, and Kettlestone Design Guidelines. Staff recommends approval of the site plan for Cove at Kettlestone Plat 4, Lot 2, subject to remaining staff comments. Discussion as follows: • General discussion of delivery access, concern there is not enough room for larger delivery vehicles • Marty Barkley of Accurate Commercial spoke and provided information that trucks serving this business are not the large-scale trucks seen at larger grocery stores such as Hy-Vee; delivery will occur via Bishop Drive, and also shared that access points have been widened to accommodate truck traffic • General discussion of the layout and capacity for planned restaurant space, which Marty confirmed is more of a deli space and small patio, with the patio being removed if any future expansion occurs • General discussion of signage and stop signs; has not come up but could be revisited if it becomes a concern Motion by Commissioner Lohse for approval of a site plan for Cove at Kettlestone Plat 4, Lot 2 (1475 SE Bishop Drive), seconded by Commissioner Koelker. Ayes: Broderick, Koelker, Beenken, Lohse, and Bankole. Nays: None. Motion carried. STAFF REVIEW AND COMMENT: Staff recommends approval of the site plan for Cove at Kettlestone Plat 4, Lot 2 subject to remaining staff comments. RECOMMENDATION: Approve the resolutions. ATTACHMENTS: I. Proposed Resolution II. Staff Report III. Site Plan IV. Building Elevations PREPARED BY: Melissa DeBoer, Planning Coordinator REVIEWED BY: PUBLIC NOTICE INFORMATION – NAME OF PUBLICATION: DATE OF PUBLICATION: THE CITY OF WAUKEE, IOWA RESOLUTION 2024- APPROVING THE SITE PLAN FOR COVE AT KETTLESTONE PLAT 4, LOT 2 IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Site Plan for Cove at Kettlestone Plat 4, Lot 2, subject to remaining staff comments on September 24, 2024; AND, WHEREAS, the Site Plan for Cove at Kettlestone Plat 4, Lot 2 is in general conformance with §160 – Site and Building Development Standards Ordinance of the Waukee Municipal Code; AND, WHEREAS, the Site Plan for Cove at Kettlestone Plat 4, Lot 2 is in general conformance with §161 – Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND, NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 7th day of October, 2024, that the Site Plan for Cove at Kettlestone Plat 4, Lot 2 is approved subject to remaining staff comments. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN R. Charles Bottenberg Chris Crone Rob Grove Anna Bergman Pierce Ben Sinclair PLANNING AND ZONING COMMISSION STAFF REPORT PROJECT: Cove at Kettlestone Plat 4, Lot 2 – Site Plan PREPARED BY: Melissa DeBoer, AICP – Planning Coordinator REPORT DATE: September 20, 2024 MEETING DATE: September 24, 2024 GENERAL INFORMATION Owner/Applicant: Super 6, LLC Owner’s Representative: Korey Marsh, PE – Snyder & Associates, Inc. Request: The applicant is requesting approval of a site plan for a grocery store. Location and Size: Property is generally located south of SE University Avenue and west of SE Waco Place, containing approximately 1.62 acres. Property Address: 1475 SE Bishop Drive AREA MAP ABOVE: Aerial of Property identifying the proposed project area (outlined in BLUE). September 20, 2024 2 of 3 LAND USES AND ZONING Location Existing Land Use Comprehensive Plan Current Zoning Property in Question Vacant – Undeveloped Community Commercial C-1 / PD-1 (Community and Highway Service Commercial District / Planned Development District) North Commercial – Retail Community Commercial C-1 / PD-1 (Community and Highway Service Commercial District / Planned Development District) South Apartments Medium Density Residential C-1 / PD-1 (Community and Highway Service Commercial District / Planned Development District) East Commercial within City of West Des Moines N/A – City of West Des Moines N/A – City of West Des Moines West Commercial / Townhome Residential Community Commercial / Medium Density Residential C-1 / PD-1 (Community and Highway Service Commercial District / Planned Development District) BACKGROUND The subject property is located within the Cove at Kettlestone development. The property is a vacant lot, platted as Lot 2, Cove at Kettlestone Plat 4. PROJECT DESCRIPTION The project includes the construction of a single-story building for a grocery store that includes a small restaurant space within the grocery store. The building is 6,000 square feet in area and 28 feet in height. The main entrance to the building is located on the north side of the building. A small patio is proposed on the east side of the building. The site plan includes a trash enclosure located at the northwest corner of the site and a monument sign located at the northeast corner of the site, adjacent to SE Waco Place. The site plan also shows a potential future addition which includes a 4,000 square foot building addition, additional parking spaces, and continuation of the drive aisles to provide continued access around the site and building. A future addition will require separate site plan approval. ACCESS AND PARKING There are two accesses into this site. One is located at the northwest corner off of the shared private drive and one is located at the southwest corner off of SE Bishop Drive. A total of 24 parking spaces are required for this project. The total amount of parking proposed is 38 spaces including 2 accessible stalls. The site plan also identifies a bicycle rack located to the northeast of the building that includes 2 bicycle parking spaces to meet the Kettlestone Design Guidelines. The proposed site plan September 20, 2024 3 of 3 meets the parking requirements. The site plan also calls out areas at the east sides of the site for future parking; this includes a possibility of an additional 15 parking stalls in the future. SIDEWALKS/TRAILS A ten-foot-wide trail will be installed along SE Waco Place and a five-foot-wide sidewalk will be installed along SE Bishop Drive adjacent to the site. A pedestrian connection is provided into the site from the public sidewalk along SE Bishop Drive. Sidewalks are proposed interior to the site in order to provide pedestrian connections from the parking lot to the proposed building and around the building. UTILITIES This site will be serviced with all public utilities. Water and sanitary sewer will be brought in from the mains located to the south along SE Bishop Drive. Storm water detention will be provided with a detention basin located at the west side of the site and with underground detention located at the southeast corner of the site. LANDSCAPING & OPEN SPACE A minimum of 15% of the project area is required to be open space. The total amount of open space proposed is 35%. The landscape plan meets the requirements of the Landscape and Open Space Ordinance and the Kettlestone Design Guidelines. ELEVATIONS The elevations of the building are proposed to be constructed mostly of stone, brick, storefront system, and Nichiha siding. The trash enclosure is proposed to be constructed of brick with metal gates. MISCELLANEOUS: The applicant has submitted a photometric plan and associated light fixture cut sheets. The lighting plan meets the lighting requirements of the Site Plan Ordinance. COMPREHENSIVE PLAN The comprehensive plan classifies the subject property as Community Commercial. The Community Commercial classification provides a variety of uses that would serve the community and are located along minor or major arterials. STAFF RECOMMENDATION The site plan is in general conformance with the Site Plan Ordinance , Comprehensive Plan, and Kettlestone Design Guidelines. Staff recommends approval of the site plan for Cove at Kettlestone Plat 4, Lot 2 subject to remaining staff comments. V: \ P r o j e c t s \ 2 0 2 4 \ 1 2 4 . 0 6 8 7 . 0 1 \ C A D D \ S P _ 1 2 4 0 6 8 7 _ T S H . d w g LO G A N M Y E R S , TI T L E S H E E T , 20 2 4 / 1 0 / 0 2 , 2: 0 8 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m KM M LJ M KS 08 - 0 6 - 2 4 20 0 ' 12 4 . 0 6 8 7 . 0 1 C1 0 0 124.0687.01 C100 CO V E A T K E T T L E S T O N E P L A T 4 , L O T 2 TI T L E S H E E T WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 08 - 2 0 - 2 4 09 - 0 3 - 2 4 09 - 1 6 - 2 4 10 - 0 1 - 2 4 LJ M LJ M LJ M LJ M 1234 TT N - R R W - S S SITE PLAN FOR COVE AT KETTLESTONE PLAT 4, LOT 2 1475 SE BISHOP DRIVE CITY OF WAUKEE, DALLAS COUNTY, IOWA VICINITY MAP PROJECT LOCATION SCALE: 1" = 200' I hereby certify that this engineering document was prepared by me or under my direct personal supervision and that I am a duly licensed Professional Engineer under the laws of the State of Iowa. Korey M. Marsh, P.E.Date License Number P25347 My License Renewal Date is December 31, 2024 Pages or sheets covered by this seal: KOREY M. MARSH P25347 D P R O F E L NS E ICE IONAL EN G I N E ER AIOW SS P E F RO S S O N LA I AC PNALCDS CARH E CE T TII A ETST F IO AW O License Expires: June 30, 2025 CLAY R. SCHNECKLOTH 512 LANDSCAPE ARCHITECT NO. Clay R. Schneckloth, PLA License Number Pages or sheets covered by this seal: 512 Date I hereby certify that the portion of this technical submission described below was prepared by me or under my direct supervision and responsible charge. I am a duly licensed Professional Landscape Architect under the laws of the State of Iowa. OWNER/DEVELOPER SUPER 6, LLC 1910 WADDELL WAY WAUKEE, IOWA 50263 CONTACT: KALYAN TOTTEMPUDI PHONE: (470) 215-2288 ENGINEER SNYDER & ASSOCIATES, INC. 2727 SW SNYDER BOULEVARD ANKENY, IOWA 50023 CONTACT: KOREY MARSH, PE PHONE: (515)964-2020 BISHOP DRIVE C500 C100-C402, C600-C601 SE UNIVERSITY AVE 98 T H S T R E E T SE ROSEWOOD CT Sheet List Table Sheet Number Sheet Title C100 TITLE SHEET C101 PROJECT INFORMATION C200 DIMENSION PLAN C300 UTILITY PLAN C400 EROSION AND SEDIMENT CONTROL PLAN C401 GRADING PLAN C402 RAMP DETAILS C500 PLANTING PLAN C600 SITE DETAILS C601 SITE DETAILS V: \ P r o j e c t s \ 2 0 2 4 \ 1 2 4 . 0 6 8 7 . 0 1 \ C A D D \ S P _ 1 2 4 0 6 8 7 _ T S H . d w g LO G A N M Y E R S , PR O J E C T I N F O R M A T I O N , 20 2 4 / 1 0 / 0 2 , 2: 0 8 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m KM M LJ M KS 08 - 0 6 - 2 4 ## # ' 12 4 . 0 6 8 7 . 0 1 C1 0 1 124.0687.01 C101 CO V E A T K E T T L E S T O N E P L A T 4 , L O T 2 PR O J E C T I N F O R M A T I O N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 08 - 2 0 - 2 4 09 - 0 3 - 2 4 09 - 1 6 - 2 4 10 - 0 1 - 2 4 LJ M LJ M LJ M LJ M 1234 TT N - R R W - S S NOTES A.NOTIFY UTILITY PROVIDERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES AND COORDINATE WITH UTILITY PROVIDERS AS NECESSARY DURING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXISTENCE, EXACT LOCATION, AND DEPTH OF ALL UTILITIES. PROTECT ALL UTILITY LINES AND STRUCTURES NOT SHOWN FOR REMOVAL OR MODIFICATION. ANY DAMAGES TO UTILITY ITEMS NOT SHOWN FOR REMOVAL OR MODIFICATION SHALL BE REPAIRED TO THE UTILITY OWNER'S SPECIFICATIONS AT THE CONTRACTOR'S EXPENSE. B.CONSTRUCTION OF ALL STREET AND UTILITY IMPROVEMENTS SHALL CONFORM TO THE 2024 WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS, 2024 STATEWIDE URBAN DESIGN AND SPECIFICATIONS (SUDAS) AND THE SOILS REPORTS PREPARED BY OTHERS. C.LENGTH OF UTILITIES SHOWN ON PLANS ARE DIMENSIONED FROM CENTERLINE OF STRUCTURE TO CENTERLINE OF STRUCTURE. D.ALL TRAFFIC CONTROL SHALL BE PROVIDED IN ACCORDANCE WITH REQUIREMENTS SET FORTH IN THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). WHEN CONSTRUCTION ACTIVITIES OBSTRUCT PORTIONS OF THE ROADWAY, FLAGGERS SHALL BE PROVIDED. FLAGGERS SHALL CONFORM TO THE MUTCD IN APPEARANCE, EQUIPMENT AND ACTIONS. THE CONTRACTOR SHALL NOTIFY THE CITY OF WAUKEE AT LEAST ONE WEEK PRIOR TO ANY ANTICIPATED LANE CLOSURE. E.NOTIFY OWNER, ENGINEER, CITY OF WAUKEE AT LEAST 48 HOURS PRIOR TO BEGINNING WORK. CONTRACTOR SHALL ALSO NOTIFY THE CITY OF WAUKEE PUBLIC WORKS DEPARTMENT AT LEAST 48 HOURS PRIOR TO ANY PLANNED WEEKEND OR HOLIDAY WORK. F.CONSTRUCT MANHOLES AND APPURTENANCES AS WORK PROGRESSES. BACKFILL WITH SUITABLE MATERIAL AND COMPACT TO 95% MAXIMUM DENSITY. G.IN THE EVENT OF A DISCREPANCY BETWEEN THE QUANTITY ESTIMATES AND THE DETAILED PLANS, THE DETAILED PLANS SHALL GOVERN. H.ALL FIELD TILES ENCOUNTERED DURING CONSTRUCTION SHALL BE RECONNECTED OR REPAIRED AND NOTED ACCORDINGLY ON THE AS-BUILT DOCUMENTS. I. DIMENSIONS, BUILDING LOCATION, UTILITIES AND GRADING OF THIS SITE ARE BASED ON AVAILABLE INFORMATION AT THE TIME OF DESIGN. DEVIATIONS MAY BE NECESSARY IN THE FIELD. ANY SUCH CHANGES OR CONFLICTS BETWEEN THIS PLAN AND FIELD CONDITIONS ARE TO BE REPORTED TO THE ARCHITECT/ENGINEER PRIOR TO STARTING CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LAYOUT VERIFICATION OF ALL SITE IMPROVEMENTS PRIOR TO CONSTRUCTION. CONTACT CITY OF WAUKEE FOR APPROVAL OF ANY CHANGES AND THAT ANY CHANGES COMPLETED WITHOUT APPROVAL ARE SUBJECT TO REMOVAL IN ORDER TO MEET THE CITY OF WAUKEE STANDARDS. J.CONTRACTOR TO LOAD AND TRANSPORT ALL MATERIALS CONSIDERED TO BE UNDESIRABLE TO BE INCORPORATED INTO THE PROJECT TO AN APPROVED OFF-SITE WASTE SITE. K.CONTRACTOR TO STRIP AND STOCKPILE TOPSOIL FROM ALL AREAS TO BE CUT OR FILLED. RESPREAD TO FINISH GRADES TO MEET SUDAS SPECIFICATIONS SECTION 2010 FOR TOPSOIL. L.ALL PROPOSED CONTOURS AND SPOT ELEVATIONS SHOWN ARE FINISHED GRADES AND/OR TOP OF PAVING SLAB (GUTTER), UNLESS OTHERWISE NOTED. M.THE CONTRACTOR IS RESPONSIBLE FOR CLEANING DIRT AND DEBRIS FROM NEIGHBORING STREETS, DRIVEWAYS, AND SIDEWALKS CAUSED BY CONSTRUCTION ACTIVITIES AT THE END OF EACH WORK DAY AND PRIOR TO A RAIN EVENT. N.THE ADJUSTMENT OF ANY EXISTING UTILITY APPURTENANCES TO FINAL GRADE IS CONSIDERED INCIDENTAL TO THE SITE WORK. O.THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING EROSION AND SEDIMENT CONTROL MEASURES AS NECESSARY. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR MAINTAINING ANY EXISTING EROSION CONTROL MEASURES ON SITE AT THE TIME OF CONSTRUCTION. GRADING AND SOIL EROSION CONTROL CODE REQUIREMENTS SHALL BE MET BY CONTRACTOR. A COSESCO PERMIT IS REQUIRED FOR THIS PROJECT. P.CONTRACTOR TO COORDINATE NATURAL GAS, ELECTRICAL, TELEPHONE AND ANY OTHER FRANCHISE UTILITY SERVICES WITH UTILITY SERVICE PROVIDER, CITY OF WAUKEE, AND THE OWNER PRIOR TO CONSTRUCTION. Q.IF STORM SEWER CROSSES ABOVE WATER MAIN OR CROSSES LESS THAN 18" BELOW A WATER MAIN THEN STORM SEWER SHALL BE CONSTRUCTED OF REINFORCED CONCRETE WITH A FLEXIBLE O-RING GASKET RATED AT 13 PSI OR GREATER. O-RING GASKET JOINTS SHALL BE INSTALLED ON EACH SIDE OF THE CROSSING UNTIL THE NORMAL DISTANCE FROM THE WATER MAIN TO THE STORM SEWER IS AT LEAST TEN FEET. R.A PRE-CONSTRUCTION MEETING WITH THE CITY OF WAUKEE WILL BE REQUIRED A MINIMUM OF ONE WEEK PRIOR TO CONSTRUCTION ACTIVITIES BEGINNING. S.ALL STAKING SHALL BE DONE UNDER THE DIRECTION OF A LICENSED ENGINEER OR LAND SURVEYOR. T.ANY CHANGES PROPOSED TO THE DRAWINGS DURING CONSTRUCTION SHALL BE APPROVED IN WRITING BY THE CITY OF WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT PRIOR TO CONSTRUCTION. U.THE CONTRACTOR IS RESPONSIBLE FOR ANY CHANGES MADE DURING CONSTRUCTION THAT HAVE NOT BEEN GRANTED APPROVAL IN WRITING BY THE CITY OF WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT. V.ALL SANITARY SEWER AND STORM SEWER SHALL BE CLEANED AND TELEVISED PRIOR TO PAVING. THE CITY OF WAUKEE SHALL WITNESS ALL CLEANING AND TELEVISING. COPIES OF THE REPORT AND VIDEO SHALL BE PROVIDED TO THE CITY OF WAUKEE. ALL SANITARY SEWER MANHOLES SHALL BE VACUUM TESTED. W.PLACE 3/4" EXPANSION JOINT BETWEEN ALL PCC PAVEMENT/SIDEWALKS AND BUILDINGS. PLACE 1/2" EXPANSION JOINT BETWEEN SIDEWALKS AND PCC PAVEMENT. THE PCC RAMP JOINT LOCATED AT THE BACK OF CURB AND ALL EXPANSION JOINTS SHALL BE SEALED. X.AS-BUILTS SHALL BE PROVIDED TO THE WAUKEE ENGINEERING DEPARTMENT INCLUDING ALL UTILITIES AND AS-BUILT GRADES FOR DRAINAGE SWALES, OVERFLOWS, ACCESSIBLE RAMPS AND DETENTION FACILITIES. THE CONTRACTOR SHALL PROVIDE INFORMATION TO THE DESIGN ENGINEER FOR INCLUSION ON THE RECORD AS-BUILT DRAWINGS. Y.ALL UTILITIES INCLUDING PRIVATE UTILITIES SHALL BE CONSTRUCTED TO THE 2024 CITY OF WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND ALL UTILITIES SHALL BE TESTED TO CITY STANDARDS. THE CITY SHALL WITNESS ALL TESTING. Z.CONSTRUCTION OPERATIONS SHALL PROTECT STORM SEWERS AND DRAINAGE WAYS FROM ALLOWING CONCRETE SLURRY FROM CONCRETE OPERATIONS TO DISCHARGE OFFSITE. AA. CONTRACTOR SHALL COORDINATE ALL TIE-IN TO UTILITIES WITH THE CITY OF WAUKEE ENGINEERING DEPARTMENT AND CITY OF WAUKEE ENGINEERING DEPARTMENT SHALL WITNESS ALL TIE-INS. BB. ALL FIRE HYDRANTS WILL BE REQUIRED TO HAVE 5-INCH STORZ FITTINGS. CC. CONTRACTOR IS TO PROVIDE SHOP DRAWING SUBMITTALS OF CONSTRUCTION MATERIALS PRIOR TO CONSTRUCTION. DD. PRIOR TO ANY LANE CLOSURE THE CONTRACTOR IS RESPONSIBLE FOR HAVING A DIGITAL MESSAGE BOARD NOTIFYING DRIVERS OF LANE CLOSURES AT LEAST ONE WEEK PRIOR TO ANY CLOSURE. CONTRACTOR IS TO COORDINATE ANY LANE/ROAD CLOSURES WITH THE CITY OF WAUKEE. EE. APPROVED FIRE APPARATUS ACCESS ROADS SHALL BE PROVIDED FOR EVERY FACILITY, BUILDING, OR PORTION OF A BUILDING AS SOON AS CONSTRUCTION COMMENCES. THE FIRE APPARATUS ACCESS ROAD SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 503.2 AND THIS SECTION SHALL EXTEND TO WITHIN 100 FEET OF ALL PORTIONS OF THE EXTERIOR WALLS OF THE FIRST STORY OF THE BUILDING AS MEASURED BY AN APPROVED ROUTE AROUND THE EXTERIOR OF THE BUILDING OR FACILITY. FF. ALL SIGNAGE REQUIRES A SEPARATE PERMIT FROM THE CITY OF WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT. GG. FUTURE ADDITION WILL REQUIRE A SEPARATE SITE PLAN APPROVAL. UTILITY QUALITY SERVICE LEVELS QUALITY LEVELS OF UTILITIES ARE SHOWN IN THE PARENTHESES WITH THE UTILITY TYPE AND WHEN APPLICABLE, SIZE. THE QUALITY LEVELS ARE BASED ON THE CI / ASCE 38-02 STANDARD. QUALITY LEVEL (D) INFORMATION IS DERIVED FROM EXISTING UTILITY RECORDS OR ORAL RECOLLECTIONS. QUALITY LEVEL (C) INFORMATION IS OBTAINED BY SURVEYING AND PLOTTING VISIBLE ABOVE-GROUND UTILITY FEATURES AND USING PROFESSIONAL JUDGMENT IN CORRELATING THIS INFORMATION WITH QUALITY D INFORMATION. QUALITY LEVEL (B) INFORMATION IS OBTAINED THROUGH THE APPLICATION OF APPROPRIATE SURFACE GEOPHYSICAL METHODS TO DETERMINE THE EXISTENCE AND APPROXIMATE HORIZONTAL POSITION OF SUBSURFACE UTILITIES. QUALITY LEVEL (A) IS HORIZONTAL AND VERTICAL POSITION OF UNDERGROUND UTILITIES OBTAINED BY ACTUAL EXPOSURE OR VERIFICATION OF PREVIOUSLY EXPOSED SUBSURFACE UTILITIES, AS WELL AS THE TYPE, SIZE, CONDITION, MATERIAL, AND OTHER CHARACTERISTICS. UTILITY WARNING THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR RECORDS OBTAINED. THE SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES OR SUBSURFACE FEATURES SHOWN COMPRISE ALL SUCH ITEMS IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UTILITIES OR SUBSURFACE FEATURES SHOWN ARE IN THE EXACT LOCATION INDICATED EXCEPT WHERE NOTED AS QUALITY LEVEL A. FEATURES EXISTING PROPOSED Spot Elevation Contour Elevation Fence (Barbed, Field, Hog) Fence (Chain Link) Fence (Wood) Fence (Silt) Tree Line Tree Stump Deciduous Tree \\ Shrub Coniferous Tree \\ Shrub Communication Overhead Communication Fiber Optic Underground Electric Overhead Electric Gas Main with Size High Pressure Gas Main with Size Water Main with Size Sanitary Sewer with Size Duct Bank Test Hole Location for SUE w/ID (*) Denotes the survey quality service level for utilities Sanitary Manhole Storm Sewer with Size Storm Manhole Single Storm Sewer Intake Double Storm Sewer Intake Fire Hydrant Fire Hydrant on Building Water Main Valve Water Service Valve Well Utility Pole Guy Anchor Utility Pole with Light Utility Pole with Transformer Street Light Yard Light Electric Box Electric Transformer Traffic Sign Communication Pedestal Communication Manhole Communication Handhole Fiber Optic Manhole Fiber Optic Handhole Gas Valve Gas Manhole Gas Apparatus Fence Post or Guard Post Underground Storage Tank Above Ground Storage Tank Sign Satellite Dish Mailbox Sprinkler Head Irrigation Control Valve LEGEND ○ 1 2 2 5 X 1225.25 ● X 1 2 2 5 1225.25 FEATURES FOUND SET Section Corner 1/2" Rebar, Cap # 11579 (Unless Otherwise Noted) ROW Marker ROW Rail Control Point Bench Mark Platted Distance P Measured Bearing & Distance M Recorded As R Deed Distance D Calculated Distance C Minimum Protection Elevation MPE Centerline Section Line 1/4 Section Line 1/4 1/4 Section Line Easement Line POLLUTION PREVENTION NOTES A.POLLUTION PREVENTION AND EROSION PROTECTION 1.CODE COMPLIANCE: THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL POTENTIAL POLLUTION AND SOIL EROSION CONTROL REQUIREMENTS OF THE IOWA CODE, THE IOWA DEPARTMENT OF NATURAL RESOURCES (IDNR) NPDES PERMIT, THE U.S. CLEAN WATER ACT AND ANY LOCAL ORDINANCES. THE CONTRACTOR SHALL TAKE ALL NECESSARY STEPS TO PROTECT AGAINST EROSION AND POLLUTION FROM THIS PROJECT SITE AND ALL OFF-SITE BORROW OR DEPOSIT AREAS DURING PERFORMANCE OR AS A RESULT OF PERFORMANCE. 2.DAMAGE CLAIMS: THE CONTRACTOR WILL HOLD THE OWNER AND ARCHITECT / ENGINEER HARMLESS FROM ANY AND ALL CLAIMS OF ANY TYPE WHATSOEVER RESULTING FROM DAMAGES TO ADJOINING PUBLIC OR PRIVATE PROPERTY, INCLUDING REASONABLE ATTORNEY FEES INCURRED TO OWNER. FURTHER, IF THE CONTRACTOR FAILS TO TAKE NECESSARY STEPS TO PROMPTLY REMOVE EARTH SEDIMENTATION OR DEBRIS WHICH COMES ONTO ADJOINING PUBLIC OR PRIVATE PROPERTY, THE OWNER MAY, BUT NEED NOT, REMOVE SUCH ITEMS AND DEDUCT THE COST THEREOF FROM AMOUNTS DUE TO THE CONTRACTOR. B.STORM WATER DISCHARGE PERMIT 1.THIS PROJECT REQUIRES COVERAGE UNDER THE NPDES GENERAL PERMIT NO. 2 FOR STORM WATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITIES FROM THE IDNR, AS REQUIRED BY THE ENVIRONMENTAL PROTECTION AGENCY (EPA). THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS ARE RESPONSIBLE FOR COMPLIANCE WITH AND FULFILLMENT OF ALL REQUIREMENTS OF THE NPDES GENERAL PERMIT NO. 2 AS SPECIFIED IN THE CONTRACT DOCUMENTS. 2.ALL DOCUMENTS RELATED TO THE STORM WATER DISCHARGE PERMIT, INCLUDING, BUT NOT LIMITED TO, THE NOTICE OF INTENT, PROOF OF PUBLICATIONS, DISCHARGE AUTHORIZATION LETTER, CURRENT SWPPP, SITE INSPECTION LOG, AND OTHER ITEMS, SHALL BE KEPT ON SITE AT ALL TIMES AND MUST BE PRESENTED TO ANY JURISDICTIONAL AGENCIES UPON REQUEST. FAILURE TO COMPLY WITH THE NPDES PERMIT REQUIREMENTS IS A VIOLATION OF THE CLEAN WATER ACT AND THE CODE OF IOWA. 3.A "NOTICE OF DISCONTINUATION" MUST BE FILED WITH THE IDNR UPON FINAL STABILIZATION OF THE DISTURBED SITE AND REMOVAL OF ALL TEMPORARY EROSION CONTROL MEASURES. ALL PLANS, INSPECTION REPORTS, AND OTHER DOCUMENTS MUST BE RETAINED FOR A PERIOD OF THREE YEARS AFTER PROJECT COMPLETION. THE CONTRACTOR SHALL RETAIN A RECORD COPY AND PROVIDE THE ORIGINAL DOCUMENTS TO THE OWNER UPON PROJECT ACCEPTANCE AND/OR SUBMITTAL OF THE NOTICE OF DISCONTINUATION. C.POLLUTION PREVENTION PLAN 1.THE STORM WATER POLLUTION PREVENTION PLAN (SWPPP) IS A SEPARATE DOCUMENT IN ADDITION TO THESE PLAN DRAWINGS. THE CONTRACTOR SHOULD REFER TO THE SWPPP FOR ADDITIONAL REQUIREMENTS AND MODIFICATIONS TO THE POLLUTION PREVENTION PLAN MADE DURING CONSTRUCTION. 2.THE SWPPP ILLUSTRATES GENERAL MEASURES AND BEST MANAGEMENT PRACTICES (BMP) FOR COMPLIANCE WITH THE PROJECT'S NPDES PERMIT COVERAGE. ALL BMP'S AND EROSION CONTROL MEASURES REQUIRED AS A RESULT OF CONSTRUCTION ACTIVITIES ARE THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY, NOTE AND IMPLEMENT. ADDITIONAL BMP'S FROM THOSE SHOWN ON THE PLAN MAY BE REQUIRED. 3.THE SWPPP AND SITE MAP SHOULD BE EXPEDITIOUSLY REVISED TO REFLECT CONSTRUCTION PROGRESS AND CHANGES AT THE PROJECT SITE. 4.THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL REQUIREMENTS OF THE GENERAL PERMIT AND SWPPP, INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING BMP'S UNLESS INFEASIBLE OR NOT APPLICABLE: a.UTILIZE OUTLET STRUCTURES THAT WITHDRAW WATER FROM THE SURFACE WHEN DISCHARGING FROM BASINS, PROVIDE AND MAINTAIN NATURAL BUFFERS AROUND SURFACE WATERS, DIRECT STORM WATER TO VEGETATED AREAS TO INCREASE SEDIMENT REMOVAL AND MAXIMIZE STORM WATER INFILTRATION, AND MINIMIZE SOIL COMPACTION. b.INSTALL PERIMETER AND FINAL SEDIMENT CONTROL MEASURES SUCH AS SILT BARRIERS, DITCH CHECKS, DIVERSION BERMS, OR SEDIMENTATION BASINS DOWNSTREAM OF SOIL DISTURBING ACTIVITIES PRIOR TO SITE CLEARING AND GRADING OPERATIONS. c.PRESERVE EXISTING VEGETATION IN AREAS NOT NEEDED FOR CONSTRUCTION AND LIMIT TO A MINIMUM THE TOTAL AREA DISTURBED BY CONSTRUCTION OPERATIONS AT ANY TIME. d.MAINTAIN ALL TEMPORARY AND PERMANENT EROSION CONTROL MEASURES IN WORKING ORDER, INCLUDING CLEANING, REPAIRING, REPLACEMENT, AND SEDIMENT REMOVAL THROUGHOUT THE PERMIT PERIOD. CLEAN OR REPLACE SILT CONTROL DEVICES WHEN THE MEASURES HAVE LOST 50% OF THEIR ORIGINAL CAPACITY. e.INSPECT THE PROJECT AREA AND CONTROL DEVICES (BY QUALIFIED PERSONNEL ASSIGNED BY THE CONTRACTOR) EVERY SEVEN CALENDAR DAYS. RECORD THE FINDINGS OF THESE INSPECTIONS AND ANY RESULTING ACTIONS IN THE SWPPP WITH A COPY SUBMITTED WEEKLY TO THE OWNER OR ENGINEER DURING CONSTRUCTION. REVISE THE SWPPP AND IMPLEMENT ANY RECOMMENDED MEASURES WITHIN 7 DAYS. f.PREVENT ACCUMULATION OF EARTH AND DEBRIS FROM CONSTRUCTION ACTIVITIES ON ADJOINING PUBLIC OR PRIVATE PROPERTIES, INCLUDING STREETS, DRIVEWAYS, SIDEWALKS, DRAINAGEWAYS, OR UNDERGROUND SEWERS. REMOVE ANY ACCUMULATION OF EARTH OR DEBRIS IMMEDIATELY AND TAKE REMEDIAL ACTIONS FOR FUTURE PREVENTION. g.INSTALL NECESSARY CONTROL MEASURES SUCH AS SILT BARRIERS, EROSION CONTROL MATS, MULCH, DITCH CHECKS OR RIPRAP AS SOON AS AREAS REACH THEIR FINAL GRADES AND AS CONSTRUCTION OPERATIONS PROGRESS TO ENSURE CONTINUOUS RUNOFF CONTROL. PROVIDE INLET AND OUTLET CONTROL MEASURES AS SOON AS STORM SEWERS ARE INSTALLED. h.RESPREAD A MINIMUM OF 8 INCHES OF TOPSOIL (INCLUDING TOPSOIL FOUND IN SOD) ON ALL DISTURBED AREAS, EXCEPT WHERE PAVEMENT, BUILDINGS OR OTHER IMPROVEMENTS ARE LOCATED. i.STABILIZE UNDEVELOPED, DISTURBED AREAS WITH MULCH, TEMPORARY SEED MIX, PERMANENT SEED MIX, SOD, OR PAVEMENT IMMEDIATELY AS SOON AS POSSIBLE UPON COMPLETION OR DELAY OF GRADING OPERATIONS. INITIATE STABILIZATION MEASURES IMMEDIATELY AFTER CONSTRUCTION ACTIVITY IS FINALLY COMPLETED OR TEMPORARILY CEASED ON ANY PORTION OF THE SITE AND WHICH WILL NOT RESUME FOR A PERIOD EXCEEDING 14 CALENDAR DAYS. j.COORDINATE LOCATIONS OF STAGING AREAS WITH THE OWNER AND RECORD IN THE SWPPP. UNLESS NOTED OTHERWISE, STAGING AREAS SHOULD CONTAIN THE FOLLOWING: JOB TRAILERS, FUELING / VEHICLE MAINTENANCE AREA, TEMPORARY SANITARY FACILITIES, MATERIALS STORAGE, AND CONCRETE WASHOUT FACILITY. CONTROL RUNOFF FROM STAGING AREAS WITH DIVERSION BERMS AND/OR SILT BARRIERS AND DIRECT TO A SEDIMENT BASIN OR OTHER CONTROL DEVICE WHERE POSSIBLE. CONCRETE WASHOUT MUST BE CONTAINED ONSITE. k.REMOVE ALL TEMPORARY EROSION CONTROL MEASURES AND SITE WASTE PRIOR TO FILING OF THE "NOTICE OF DISCONTINUATION". GENERAL USE GENERAL COMMERCIAL/OFFICE PROPERTY DESCRIPTION LOT 2, COVE AT KETTLESTONE PLAT 4 BEING AN OFFICIAL PLAT DALLAS COUNTY, IOWA. (1.73 AC) PROPERTY ADDRESS 1475 SE BISHOP DRIVE WAUKEE, IA 50263 ZONING PLANNED UNIT DEVELOPMENT/ C-1 (COMMUNITY AND HIGHWAY SERVICE COMMERCIAL DISTRICT) RECORDED WITH BOOK 2016 PAGE 2362 OPEN SPACE SITE AREA: 70,721 SF (1.62 AC) IMPERVIOUS AREA:27,207 SF (38.47%) PERVIOUS AREA:43,514 SF (61.53%) BULK REGULATIONS FRONT YARD= 25 FEET LOT AREA = NONE SIDE YARD = NONE EXCEPT FOR 10 FEET ADJACENT TO RESIDENTIAL REAR YARD = NONE EXCEPT FOR 25 FEET ADJACENT TO RESIDENTIAL MINIMUM OPEN SPACE = 15% PARKING REQUIREMENTS 4 SPACES PER 1000 SF OF RETAIL/ GENERAL COMMERCIAL: (6,000 SF / 1000 SF) x 4 SPACES = 24 SPACES REQUIRED 38 SPACES PROVIDED (INCLUDING 2 HANDICAP ACCESSIBLE SPACES) 4,000 SF FUTURE EXPANSION: 4 SPACES PER 1,000 SF OF RETAIL/ GENERAL COMMERCIAL: (2,820 SF / 1,000 SF) x 4 SPACES = 11 FUTURE SPACES REQUIRED 15 SPACES PER 1,000 SF OF RESTAURANT (1,180 SF/ 1,000 SF) x 15 SPACES = 18 FUTURE SPACES REQUIRED 29 TOTAL FUTURE SPACES REQUIRED 15 FUTURE SPACES TO BE PROVIDED (INCLUDING 1 ACCESSIBLE STALL) 53 TOTAL SPACES TO BE PROVIDED (INCLUDING 3 ACCESSIBLE STALLS) BICYCLE PARKING:3% OF REQUIRED STALL 40 STALLS x 0.03 =2 BICYCLE PARKING SPACES 2 BICYCLE SPACES PROVIDED BUILDING DESCRIPTION 28' HEIGHT 6,000 SF GROCERY STORE CONTROL POINTS IOWA STATE PLANES SOUTH COORDINATE SYSTEM NAD83(2011)(EPOCH 2010.00) IARTN DERIVED - US SURVEY FEET CP1 N=582886.23 E=1545932.77 ELEV=1058.72 SET CUT "X" AT DOUBLE BACK OF CURB INTAKE, SOUTH SIDE OF SE BISHOP DRIVE, 40' WEST OF TOWNHOME ENTRANCE. CP2 N=582898.81 E=1545491.01 ELEV=1060.50 SET CUT "X" AT SOUTH BACK OF CURB INTAKE OF SE BISHOP DRIVE, 5' NORTH OF STREET LIGHT, 50' WEST OF SOUTH ENTRANCE. CP3 N=583247.92 E=1545528.02 ELEV=1058.62 SET CUT "X" AT SOUTH BACK OF CURB SE UNIVERSITY AVE, 5' NORTH OF STREET LIGHT, 150' EAST OF EMERALD DRIVE. CP4 N=583246.40 E=1545986.91 ELEV=1058.54 SET CUT "X" AT SOUTH BACK OF CURB SE UNIVERSITY AVE, 20' NORTH OF POWER POLE, 75' SOUTH OF HYDRANT. BENCHMARKS NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88 - GEOID12A) IARTN DERIVED - US SURVEY FEET BM1 ELEV=1061.03 BURY BOLT ON HYDRANT, IN FRONT OF UNIT #1356, SOUTH SIDE SE BISHOP DRIVE. BM2 ELEV=1062.50 BURY BOLT ON HYDRANT, IN FRONT OF UNIT #1296, SOUTH SIDE SE BISHOP DRIVE. UTILITY CONTACT INFORMATION UTILITY CONTACT FOR MAPPING INFORMATION SHOWN AS RECEIVED FROM THE IOWA ONE CALL DESIGN REQUEST SYSTEM, TICKET NUMBER 552003655. AUREON NETWORK SERVICES JEFF KLOCKO 515-830-0445 JEFF.KLOCKO@AUREON.COM CENTURYLINK TOM STURMER 720-578-8090 THOMAS.STURMER@CENTURYLINK.COM CONSOLIDATED COMMUNICATIONS JUSTIN GREV 507-386-3606 JUSTIN.GREV@CONSOLIDATED.COM INTERNET CONSULTING SERVICES, ADAM WOODARD 515-268-4045 LOCATES@ICS-LLC.NET MEDIACOM COMMUNICATIONS CORP PAUL MAY 515-246-2252 PMAY@MEDIACOMCC.COM MI-FIBER JACK JONES 515-897-9192 JACK@GRM.NET F01-FIBER OPTIC FO2-FIBER OPTIC C1-COMMUNICATIONS NO RESPONSE NO RESPONSE CLEAR NO RESPONSE E-ELECTRIC OE-OVERHEAD ELECTRIC NO RESPONSE FO3-FIBER OPTIC FO4-FIBER OPTIC W-WATER S-SANITARY SEWER G-GAS MIDAMERICAN ENERGY CRAIG RANFELD 515-252-6632 MECDSMDESIGNLOCATES@MIDAMERICAN.COM NEXGEN INTEGRATED COMMUNICATIO RYAN ROLWES 515-369-7131 RYAN@NEXGENCOM.COM UNITE PRIVATE NETWORKS, LLC JOE KILZER 816-425-3556 UPNGIS@UPNFIBER.COM WINDSTREAM COMMUNICATIONS LOCATE DESK 800-289-1901 LOCATE.DESK@WINDSTREAM.COM WAUKEE, CITY OF TIM ROYER 515-978-7920 TROYER@WAUKEE.ORG T PROPOSED BUILDING 6,000 SF FFE = 1056.00 FIRE RISER ROOM 6 9 10 13 FUTURE ADDITION 4,000 SF TR A S H 10' Existing Public Utility Easement (Bk 2015, Pg 20833) 10' Existing Public Utility Easement (Bk 2019, Pg 21475) 20' Existing Storm Sewer Easement (Bk 2015, Pg 20833) Existing Public Sidewalk Easement (Bk 2019, Pg 21474) 10' Existing Sanitary Sewer Easement (Bk 2015, Pg 20833) 15' Existing Private Sanitary Sewer Easement (Bk 2022, Pg 9126) Existing 30' Private Access Easement (Bk 2022, Pg 9126) 25' B U I L D I N G S E T B A C K 1475 SE BISHOP DR 10' Existing Gas Easement (Bk 2022, Pg 9125) SE Corner Lot 1 Coffee Bean Addition Plat 1 Found 3/4" Iron Pipe Yellow Plastic Cap #14775 S E BIS H O P DRIVE 70.00' R O W SE W A C O P L A C E / 9 8 T H S T R E E T 85 . 0 0 ' R O W 75,242 SF 1.73 AC Existing Feeder Main Easement (Bk 2005, Pg 1875) 10' Private Water Easement 15' Private Storm Sewer Easement 70,721 SF 1.62 AC LOT 2 R5' R10' R 5 ' R25 ' R4 ' R 5 ' R5' R25' R5'R 5 ' R1 5 ' R 2 0 ' R15 ' R 1 0 ' R 5 ' 18 ' 25 ' 18 ' 5' 5' 9.5'9' 18 ' 25 ' 40 ' 5' 5' 18' 25' 5' 5' 18 ' 12' 9.5'9' 22 ' 12' 60 ' 106.7' 203 Steel Lids Vertical Vent Gas Warning Post Steel Pole With Antenna Proposed MidAmerican Line Rip/Rap C o n c r e t e S i d e w a l k C O N C R E T E CONCRETE Electric Box FIRE RISER ROOM PROPOSED BUILDING 11,890 SF T TRASH TRASH 4C 4B4B 4A 4A 4A 3A 3A 3A 3A 3B 3B 3B 3B 3B 3C 3C 3C 3C 3C 3C 3G 3G 3G 3C 3H 3J 2A 3I 2B 3E3E 3D 3D 3D 3D 3D 3D 3D 3D 3D 6C 6B 6A 6D 1B 1A 1A 1B 1B 1B 1B 3F 3F 3F 3F 3K 2C 5A 5. 1 ' 7' 10' 5' 3L 3L 5B R2.5' 20' CURVE TABLE CURVE NO.Δ RADIUS ARC LENGTH TANGENT CHORD BEARING/LENGTH 5' 5' 8 V: \ P r o j e c t s \ 2 0 2 4 \ 1 2 4 . 0 6 8 7 . 0 1 \ C A D D \ S P _ 1 2 4 0 6 8 7 _ D I M . d w g LO G A N M Y E R S , DI M E N S I O N P L A N , 20 2 4 / 1 0 / 0 2 , 2: 0 8 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 20 BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m KM M LJ M KS 08 - 0 6 - 2 4 20 ' 12 4 . 0 6 8 7 . 0 1 C2 0 0 124.0687.01 C200 CO V E A T K E T T L E S T O N E P L A T 4 , L O T 2 DI M E N S I O N P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 08 - 2 0 - 2 4 09 - 0 3 - 2 4 09 - 1 6 - 2 4 10 - 0 1 - 2 4 LJ M LJ M LJ M LJ M 1234 TT N - R R W - S S DIMENSION PLAN CONSTRUCTION NOTES 1.EXISTING FEATURES, PROTECT THE FOLLOWING: A.PAVEMENTS TO REMAIN. B.PROTECT EXISTING UTILITIES, ANY DAMAGE TO THE EXISTING UTILITIES THAT ARE NOT SCHEDULED FOR MODIFICATION OR DEMOLITION SHALL BE REMEDIED AT THE CONTRACTORS EXPENSE WITH WORK BEING PREFORMED TO THE UTILITY OWNER'S SPECIFICATION. 2.DEMOLITION, REMOVE THE FOLLOWING: A.REMOVE 2 FOOT CURB & GUTTER SECTION. SAWCUT FULL DEPTH AT REMOVAL LIMITS. B.SAWCUT FULL DEPTH AT REMOVAL LIMITS, REMOVE AND DISPOSE OF EXISTING PCC. C.REMOVE AND DISPOSE OF EXISTING STORM SEWER FLARED END SECTION.. 3.PAVEMENTS, PROVIDE THE FOLLOWING: A.PCC PARKING, 6" DEPTH PAVEMENT ON 12" DEPTH PREPARED SUBGRADE COMPACTED TO 95% STANDARD PROCTOR DENSITY. B.PCC DRIVES, 7" DEPTH PAVEMENT ON 12" DEPTH PREPARED SUBGRADE COMPACTED TO 95% STANDARD PROCTOR DENSITY. C.PCC SIDEWALKS, 4" DEPTH PAVEMENT. D.6" STANDARD CURB. SEE DETAIL THIS SHEET. E.PCC INTEGRAL SIDEWALK AND CURB. SEE DETAIL THIS SHEET. F.PEDESTRIAN RAMP WITH A MAXIMUM SLOPE OF 8.33%. PROVIDE DETECTABLE WARNING SYSTEM AT RAMPS WHERE PEDESTRIAN TRAFFIC MEETS VEHICULAR TRAFFIC. G.10' WIDE PCC TRAIL, 5" DEPTH PCC. H.4" PCC PATIO. I.CONNECT TO EXISTING PAVEMENT WITH SUDAS TYPE 'A' CONNECTION. J.CONNECT TO EXISTING PAVEMENT WITH SUDAS TYPE 'B' CONNECTION. K.5' WIDE CUNETTE. L.PCC DRIVES, 8" DEPTH PAVEMENT ON 12" DEPTH PREPARED SUBGRADE COMPACTED TO 95% STANDARD PROCTOR DENSITY. 4.PAVEMENT MARKINGS, PROVIDE THE FOLLOWING: A.4" WIDE PAINTED PARKING STALL LINES. B.PAINTED STATE OF IOWA APPROVED ACCESSIBLE PARKING SYMBOL. C.ACCESSIBLE AISLE. 45° STRIPING AT 3' ON CENTER SPACING WHERE SHOWN. 5.SIGNS, PROVIDE THE FOLLOWING: A.PROVIDE VAN ACCESSIBLE PARKING SIGNAGE AS PER ADAAG REQUIREMENTS. B.MONUMENT SIGN. COORDINATE SIZE AND LOCATION WITH ARCHITECTURAL PLANS PRIOR TO CONSTRUCTION. 6.SITE AMENITIES, PROVIDE THE FOLLOWING: A.TRASH ENCLOSURE. SEE ARCHITECTURAL PLANS FOR DETAILS. B.BIKE RACK. C.TRANSFORMER. D.SCREENING WALL. SEE ARCHITECTURAL PLANS FOR DETAILS. 7.SITE LIGHTING, PROVIDE THE FOLLOWING: A.CONTRACTOR TO COORDINATE WITH THE UTILITY OWNER AND PROPERTY OWNER ALL ASPECTS OF ELECTRICAL SERVICE. B.SITE LIGHTING SHOWN IS FOR ILLUSTRATION PURPOSES ONLY. CONTRACTOR TO COORDINATE WITH THE OWNER ALL ASPECTS SITE LIGHTING PRIOR TO CONSTRUCTION. 8.THE CITY OF WAUKEE IS NOT RESPONSIBLE FOR PAVEMENT REPLACEMENT WITHIN EXISTING SANITARY SEWER EASEMENT IF PAVEMENT NEEDS TO BE REMOVED FOR MAINTENANCE OF THE SANITARY SEWER. FORM GRADE ELEV. 1 C200 6-INCH STANDARD CURB NO SCALE 6" 2 C200 INTEGRAL SIDEWALK AND CURB DETAIL NO SCALE ADJACENT PAVEMENT SIDEWALK 4" M I N 3 C200 TYPICAL PAVEMENT CROSS SECTIONS NO SCALE PCC PAVEMENT SECTION PCC SIDEWALK SECTION SLOPE AS PER PLANS 2% MAX 4 1 2" 7 1 2" 6" 12"18" R3" R3" 1" RADIUS SEALED 'E' JOINT PCC PAVEMENT, SEE PLANS FOR THICKNESS & LOCATIONS 12" DEPTH PREPARED SUBGRADE 2 - 6" LIFTS UNLESS NOTED OTHERWISE SIDEWALK PAVEMENT, SEE PLANS FOR THICKNESS & LOCATIONS 6" DEPTH PREPARED SUBGRADE PAVEMENT LEGEND 4"PCC SIDEWALK 6" PCC PAVEMENT 7" PCC PAVEMENT 8" PCC PAVEMENT 6" PCC TRAIL T PROPOSED BUILDING 6,000 SF FFE = 1056.00 FIRE RISER ROOM 6 9 10 13 FUTURE ADDITION 4,000 SF TR A S H 10' Existing Public Utility Easement (Bk 2015, Pg 20833) 10' Existing Public Utility Easement (Bk 2019, Pg 21475) 20' Existing Storm Sewer Easement (Bk 2015, Pg 20833) Existing Public Sidewalk Easement (Bk 2019, Pg 21474) 10' Existing Sanitary Sewer Easement (Bk 2015, Pg 20833) 15' Existing Private Sanitary Sewer Easement (Bk 2022, Pg 9126) Existing 30' Private Access Easement (Bk 2022, Pg 9126) 1475 SE BISHOP DR 10' Existing Gas Easement (Bk 2022, Pg 9125) SE Corner Lot 1 Coffee Bean Addition Plat 1 Found 3/4" Iron Pipe Yellow Plastic Cap #14775 S E BIS H O P DRIVE 70.00' R O W SE W A C O P L A C E / 9 8 T H S T R E E T 85 . 0 0 ' R O W 75,242 SF 1.73 AC N89°59'54"W 114.03' S38 ° 2 4 ' 5 9 " W 1 0 6 . 7 2 ' C 8 Existing Feeder Main Easement (Bk 2005, Pg 1875) 10' Private Water Easement 15' Private Storm Sewer Easement 70,721 SF 1.62 AC LOT 2 FIRE RISER ROOM PROPOSED BUILDING 11,890 SF T TRASH TRASH 203 F.L.=1055.15 12" RCP SE Rim=1056.95 Open NW=1055.70 F.L.=1051.45 12" RCP NW F.L.=1051.40 15" RCP SE Storm C/O=1057.18 Sanitary C/O=1057.84 F.L.=1051.12 12" RCP NW Sanitary C/O=1057.69 Rim=1048.82 F.L.=1043.62 15" RCP E F.L.=1043.62 15" RCP W Rim=1045.80 Intake=1045.13 F.L.=1041.17 15" RCP N F.L.=1041.06 15" RCP W F.L.=1040.90 15" RCP S F.L.=1041.32 15" RCP S Rim=1046.26 Intake=1045.44 F.L.=1041.54 15" RCP E F.L.=1041.47 24" RCP N F.L.=1041.18 30" RCP S Rim=1051.24 Intake=1050.37 F.L.=1047.43 15" CPP N Rim=1051.32 Intake=1050.47 F.L.=1047.77 18" CPP NW F.L.=1046.89 15" CPP S F.L.=1046.58 15" RCP E Rim=1048.94 Intake=1048.22 F.L.=1044.20 15" RCP E F.L.=1044.26 15" RCP W F.L.=1044.12 24" RCP N F.L.=1043.99 24" RCP S Rim=1056.41 Inv=1042.36 8" TRUSS SW Inv=1042.36 8" TRUSS W Steel Lids Vertical Vent Gas Warning Post Steel Pole With Antenna Proposed MidAmerican Line Rip/Rap C o n c r e t e S i d e w a l k Rim=1052.27 Intake=1051.65 F.L.=1047.51 15" RCP E F.L.=1047.50 15" RCP SW C O N C R E T E CO N C R E T E CONCRETE Electric Box INV: 1050.50 INV: 1050.50 INV: 1050.50 INV: 1042.50 BP: 1047.83 (ST) TP: 1046.52 (SAN) BP: 1049.49 (ST) TP: 1047.99 (WAT) ADJUST RIM TO GRADE 100 YR ELEV: 1053.33 100 YR ELEV: 1051.55 100 YR ELEV: 1052.06 100 YR ELEV: 1053.61 BP: 1050.42 (ST) TP: 1048.34 (WAT) BP: 1048.79 (WAT) TP: 1043.28 (SAN) OVERFLOW 1053.87 OVERFLOW 1054.45 BASIN OVERFLOW 1054.45 1A 1A 1A 1A 1A 3C 3B3A 3D 2A2D 2B 2B 2C 2E 3E 3F 3G 3G 3A 5 5 3H 5 3I 4 5 EAST BASIN (UNDERGROUND) 100 YR ELEVATION: 1044.32 WQV ELEVATION: 1044.00 WEST BASIN 100 YR ELEV= 1053.18 INV: 1050.86 ST-1, INTAKE, SW-501 T/C: 1053.87 INV: 1050.43 (IN E) INV: 1050.33 (OUT NW) ST-5, INTAKE, SW-501 T/C: 1053.73 INV: 1050.13 (OUT S) ST-3A, 30'' NYLOPLAST DRAIN BASIN RIM: 1053.02 INV: 1046.93 (IN W) ST-3, INTAKE, SW-501 T/C: 1052.42 INV: 1048.51 (IN NW) INV: 1048.41 (OUT E) ST-5A, 30'' NYLOPLAST DRAIN BASIN RIM: 1052.34 INV: 1047.83 (IN N) INV: 1042.32 (IN W) INV: 1044.60 (OUT S) ST-7, 30'' NYLOPLAST DRAIN BASIN RIM: 1051.93 INV: 1044.60 (IN S) INV: 1048.01 (IN W) INV: 1041.32 (OUT S) ST-4, INTAKE, SW-501 T/C: 1051.97 ST-1A, 15'' FES INV: 1050.20 ST-2, ??? INV: 1050.15 1 8 3 L F O F 6 " H D P E @ 0 . 9 0 % 77 LF OF 1 5 " H D P E @ 1 . 9 1 % 11 1 L F O F 1 2 " H D P E @ 2 . 0 8 % 55 LF OF 12" RCP @ 0.95% 8 LF OF 15" RCP @ 0.47% 13 LF OF 15" HDPE @ 0.96% ADJUST RIM TO: 1055.21 CONNECT TO EXISTING STORM SEWER. INV: 1041.28 V: \ P r o j e c t s \ 2 0 2 4 \ 1 2 4 . 0 6 8 7 . 0 1 \ C A D D \ S P _ 1 2 4 0 6 8 7 _ U T I L . d w g LO G A N M Y E R S , UT I L I T Y P L A N , 20 2 4 / 1 0 / 0 2 , 2: 0 8 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 20 BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m KM M LJ M KS 08 - 0 6 - 2 4 20 ' 12 4 . 0 6 8 7 . 0 1 C3 0 0 124.0687.01 C300 CO V E A T K E T T L E S T O N E P L A T 4 , L O T 2 UT I L I T Y P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 08 - 2 0 - 2 4 09 - 0 3 - 2 4 09 - 1 6 - 2 4 10 - 0 1 - 2 4 LJ M LJ M LJ M LJ M 1234 TT N - R R W - S S UTILTIY PLAN CONSTRUCTION NOTES 1. EXISTING FEATURES, PROTECT THE FOLLOWING: A. PROTECT EXISTING UTILITES, ANY DAMAGE TO THE EXISTING UTILITIES THAT ARE NOT SCHEDULED FOR MODIFICATION OR DEMOLITION SHALL BE REMEDIED AT THE CONTRACTORS EXPENSE WITH WORK BEING PERFORMED TO THE UTILITY OWNER'S SPECIFICATION. 2. SANITARY SEWER SERVICES; PROVIDE THE FOLLOWING: A.6" SANITARY SEWER SERVICE LINE @ MINIMUM 1.0% B.CONNECT TO BUILDING SANITARY SERVICE. VERIFY LOCATION AND ELEVATION WITH MECHANICAL PLANS PRIOR TO CONSTRUCTION. C.SANITARY SEWER CLEANOUT. D.CONNECT TO EXISTING SANITARY MANHOLE. CONTRACTOR TO VERIFY LOCATION AND ELEVATION PRIOR TO CONSTRUCTION. USE 1:1 RISER AS NECESSARY. E.WRA APPROVED GREASE INTERCEPTOR. SEE MECHANICAL PLANS FOR DETAILED DRAWINGS OF GREASE INTERCEPTOR. COORDINATE EXACT SIZE/ELEVATIONS WITH MECHANICAL PLANS PRIOR TO CONSTRUCTION. 3. WATER SERVICES, PROVIDE THE FOLLOWING: A.6" WATER SERVICE LINE. B.2" DOMESTIC WATER SERVICE WITH VALVE. C.BUILDING WATER SERVICE CONNECTION. VERIFY LOCATION AND DEPTH WITH MECHANICAL PLANS PRIOR TO CONSTRUCTION. D.CONNECT TO EXISTING WATER MAIN SERVICE STUB. CONTRACTOR TO VERIFY LOCATION AND DEPTH PRIOR TO CONSTRUCTION. E.HYDRANT ASSEMBLY. F.6"X6" TEE. G.WATER BEND. H.CONTRACTOR TO VERIFY DEPTH OF EXISTING 8" WATER MAIN. LOWER AS NECESSARY TO MAINTAIN 5.5' DEPTH. COORDINATE ANY DISRUPTION OF EXISTING SERVICE WITH ADJACENT PROPERTY OWNER PRIOR TO CONSTRUCTION. I.6" WATER VALVE. 4. COORDINATE NATURAL GAS AND ELECTRICAL SERVICES AND METER LOCATION WITH UTILITY SERVICE PROVIDER PRIOR TO CONSTRUCTION. SEE ARCHITECTURAL AND MECHANICAL PLANS FOR INTERIOR UTILITY ROUTING, METERS, DESIGN INFORMATION AND COORDINATE UTILITY CONNECTIONS ACCORDINGLY. 5. CRITICAL CROSSING. CONTRACTOR TO VERIFY ALL CROSSINGS AND PROVIDE 18" MINIMUM SEPARATION. 6. STORM SEWER IMPROVEMENTS, PROVIDE AS SHOWN: A.ROOF DRAIN COLLECTION LINE. CONNECTO TO BUILDING. SEE ARCHITECTURAL PLANS FOR DETAILS. GENERAL CONSTRUCTION NOTES A. NOTIFY THE CITY OF WAUKEE AT LEAST 48 HRS PRIOR TO CONNECTING TO ANY PUBLIC UTILITY. B. ALL UTILITIES SHALL BE TESTED TO THE CITY OF WAUKEE STANDARD SPECIFICATION FOR PUBLIC IMPROVEMENTS AND ANY TESTING OR TIE-INS SHALL BE WITNESSED BY THE CITY OF WAUKEE ENGINEERING DEPARTMENT. C. ALL SANITARY SEWER AND STORM SEWER SHALL BE CLEANED AND TELEVISED PRIOR TO PAVING. THE CITY OF WAUKEE SHALL WITNESS ALL CLEANING AND TELEVISING. COPIES OF THE REPORT AND VIDEO SHALL BE PROVIDED TO THE CITY OF WAUKEE. ALL SANITARY SEWER MANHOLES SHALL BE VACUUM TESTED. D. ALL WATERMAIN SHALL BE PRESSURE AND BACTERIA TESTED AND DECHLORINATED. T PROPOSED BUILDING 6,000 SF FFE = 1056.00 FIRE RISER ROOM 6 9 10 13 FUTURE ADDITION 4,000 SF TR A S H 203 10' Existing Public Utility Easement (Bk 2015, Pg 20833) 10' Existing Public Utility Easement (Bk 2019, Pg 21475) 10' Existing Sanitary Sewer Easement (Bk 2015, Pg 20833) 15' Existing Private Sanitary Sewer Easement (Bk 2022, Pg 9126) Existing 30' Private Access Easement (Bk 2022, Pg 9126) 25' B U I L D I N G S E T B A C K 10' Existing Gas Easement (Bk 2022, Pg 9125) SE Corner Lot 1 Coffee Bean Addition Plat 1 Found 3/4" Iron Pipe Yellow Plastic Cap #14775 S E BIS H O P DRIVE 70.00'R O W SE W A C O P L A C E / 9 8 T H S T R E E T 85 . 0 0 ' R O W 75,242 SF 1.73 AC C 8 10' Private Water Easement 15' Private Storm Sewer Easement 70,721 SF 1.62 AC LOT 2 1 0 5 5 1 0 5 5 1 0 5 1 1 0 5 1 1 0 5 2 1 0 5 2 1 0 5 3 1 0 5 3 1 0 5 4 1 0 5 4 1 0 5 6 1 0 5 6 1 0 5 7 1 0 5 7 1 0 5 8 1 0 5 9 1050 1055 10 4 9 105 1 1 0 5 2 1053 1054 1 0 5 6 1 0 5 7 1045 104 5 1050 1055 1046 104 6 1047 104 7 104 8 1048 104 9 1049 1051 1052 1053 1054 10 5 6 1055 105 3 1054 105 6 105 7 105 8 10 5 0 1046 104 7 10 4 8 10 4 9 10 5 1 1045 104 5 1050 1055 1042 10 4 2 1043 10 4 3 1044 104 4 104 6 104 6 1046 1047 1048 1049 1051 1052 1053 1054 105 6 10 5 0 1 0 5 5 10 4 9 1 0 5 1 1 0 5 2 1 0 5 3 1 0 5 4 1 0 5 6 10 5 7 1057 10 4 7 10 4 8 1055 105 1 1051 1052 1053 1054 1056 1057 10 5 5 10 4 9 10 5 4 1 0 5 4 1050 1047 1048 1049 1051 1052 10 5 3 1055 1053 1054 1056 10 5 0 1055 104 8 10 4 9 10 5 1 10 5 210 5 3 1054 1 0 5 5 1 0 5 6 1 0 5 7 1 0 5 8 LOT 1 COVE A T K E T T L E S T O N E PLAT 4 S89°59'54"E 309.34' M&P S0 ° 1 9 ' 4 7 " W 2 2 0 . 4 4 ' M & P N89°48'40"W 162.60' M&P C 2 C 1 N38 ° 2 4 ' 5 9 " E 1 0 6 . 7 2 ' M & P FIRE RISER ROOM PROPOSED BUILDING 11,890 SF T TRASH TRASH 1 0 5 4 1056 1057 105 5 105 2 STABILIZED CONSTRUCTION ENTRANCE STAGING AREA TOPSOIL STOCKPILE AREA ● ● ●●●● ● CONCRETE WASHOUT ULTIMATE DISCHARGE TO WALNUT CREEK ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●●●●●●●●●●●●●●● ● ● ● ● ● ● ● ● ● ● ● ● ● SILT FENCE (TYP.) SEDIMENT BASKET (TYP.) 5 TONS OF CLASS D RIP RAP 5' X 10' X 1.5' ● ●●●●●●●●●●● 1050 104 710481049 1051 1052 LIMITS OF DISTURBANCE 5 TONS OF EROSION STONE 5' X 10' X 1.5' POST CONSTRUCTION FACILITY WEST BASIN 100 YR ELEV= 1053.18 30 TONS OF EROSION STONE 13' X 13' X 2.5' EAST BASIN (UNDERGROUND) 100 YR ELEVATION: 1044.32 WQV ELEVATION: 1044.00 10 5 4 10 5 3 10 5 2 10 5 2 10 5 3 10 5 2 10 5 3 105 2 1051 1050 105 4 1054 1 0 5 4 1053 10 5 2 10 5 1 10 5 0 10 4 9 104 8 1059 5 TONS OF CLASS D RIP RAP 5' X 10' X 1.5' SEDIMENT BASKET (TYP.) SEDIMENT BASKET (X2) SEDIMENT BASKET (TYP.) V: \ P r o j e c t s \ 2 0 2 4 \ 1 2 4 . 0 6 8 7 . 0 1 \ C A D D \ S P _ 1 2 4 0 6 8 7 _ E R O S . d w g LO G A N M Y E R S , ER O S I O N A N D S E D I M E N T C O N T R O L P L A N , 20 2 4 / 1 0 / 0 2 , 2: 0 9 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 20 BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m KM M LJ M KS 08 - 0 6 - 2 4 20 ' 12 4 . 0 6 8 7 . 0 1 C4 0 0 124.0687.01 C400 CO V E A T K E T T L E S T O N E P L A T 4 , L O T 2 ER O S I O N A N D S E D I M E N T C O N T R O L P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 08 - 2 0 - 2 4 09 - 0 3 - 2 4 09 - 1 6 - 2 4 10 - 0 1 - 2 4 LJ M LJ M LJ M LJ M 1234 TT N - R R W - S S QUANTITIES SUDAS TYPE 4 SEEDING, FERTILIZING & MULCHING 1.00 AC. DETENTION BASIN SEEDING 0.11 AC. SOD 1.20 AC. SILT FENCE 1045 LF SEDIMENT BASKETS 5 EA CLASS D RIP-RAP 5 TONS (EROSION STONE)35 TONS DISTURBED AREA 1.64 AC. TYPICAL SILT FENCE INSTALLATION ON LONGITUDINAL SLOPES (Profile View) FLOW 'T ' S T E E L FE N C E P O S T 4' - 0 " M I N SEE PLANS FOR SPACING TYPICAL SILT FENCE INSTALLATION ON LONGITUDINAL SLOPES (Plan View) DETAILS OF SILT FENCE ON LONGITUDINAL SLOPES ATTACHMENT TO POST 200'-0" MAX LENGTH PER SECTION 600'-0" IF SLOPE IS FLATTER THAN 5% 36 " 24 " 8'-0" SPACING TYPICAL SILT FENCE DITCH CHECK BAC K S L O P E FO R E S L O P E VARIABLE (20'-0" FOR A NORMAL 10'-0" WIDE DITCH) POST SPACING (5'-0" MAX) POST SPACING 5'-0" MAX) 2" MI N 20 " M I N 1 1 2 GROUND LINE FABRIC GROUND CONTOURS INSTALL "J-HOOK" AT EACH END OF AN INDIVIDUAL SECTION OF SILT FENCE INSTALL PARALLEL TO GROUND CONTOUR FABRICGROUND LINE FABRIC POST WIRE OR CABLE TIES 2 2 1 C400 SILT FENCE DETAIL NO SCALE 1 INSERT 12 INCHES OF FABRIC A MINIMUM OF 6 INCHES DEEP (FABRIC MAY BE FOLDED BELOW THE GROUND LINE. 2 REDUCE POST SPACING TO 5'-0" AT WATER CONCENTRATION AREAS, OR AS REQUIRED TO ADEQUATELY SUPPORT FENCE. 1.PROVIDE SILT FENCE WHERE SHOWN AND AS DETAILED ON THIS SHEET. MAINTAIN AND ADJUST SILT FENCE AS NECESSARY DURING CONSTRUCTION. 2.PROVIDE SEDIMENT BASKET IN ALL INTAKES. 3.PROVIDE RIP RAP AND EROSION STONE AS SHOWN. EROSION CONTROL NOTES T PROPOSED BUILDING 6,000 SF FFE = 1056.00 FIRE RISER ROOM 6 9 10 13 FUTURE ADDITION 4,000 SF TR A S H 203 10' Existing Public Utility Easement (Bk 2015, Pg 20833) 10' Existing Public Utility Easement (Bk 2019, Pg 21475) 10' Existing Sanitary Sewer Easement (Bk 2015, Pg 20833) 15' Existing Private Sanitary Sewer Easement (Bk 2022, Pg 9126) Existing 30' Private Access Easement (Bk 2022, Pg 9126) 25' B U I L D I N G S E T B A C K 10' Existing Gas Easement (Bk 2022, Pg 9125) SE Corner Lot 1 Coffee Bean Addition Plat 1 Found 3/4" Iron Pipe Yellow Plastic Cap #14775 S E BIS H O P DRIVE 70.00'R O W SE W A C O P L A C E / 9 8 T H S T R E E T 85 . 0 0 ' R O W 75,242 SF 1.73 AC C 8 10' Private Water Easement 15' Private Storm Sewer Easement 70,721 SF 1.62 AC LOT 2 1 0 5 5 1 0 5 5 1 0 5 1 1 0 5 1 1 0 5 2 1 0 5 2 1 0 5 3 1 0 5 3 1 0 5 4 1 0 5 4 1 0 5 6 1 0 5 6 1 0 5 7 1 0 5 7 1 0 5 8 1 0 5 9 1 0 5 0 10 5 5 10 4 8 1 0 4 9 1 0 5 1 10 5 2 1053 1054 1 0 5 6 1 0 5 7 1045 104 5 1050 1055 1046 104 6 1047 104 7 104 8 1048 104 9 1049 1051 1052 1053 1054 10 5 6 1055 105 3 1054 105 6 105 7 105 8 10 5 0 1 0 4 6 1047 10 4 8 10 4 9 10 5 1 105 2 1045 104 5 1050 1055 1042 10 4 2 1043 10 4 3 1044 104 4 104 6 104 6 1046 1047 1048 1049 1051 1052 1053 1054 105 6 10 5 0 1 0 5 5 10 4 8 10 4 9 1 0 5 1 1 0 5 2 1 0 5 3 1 0 5 4 1 0 5 6 10 5 7 1057 10 4 7 10 4 8 (105 6 . 1 2 ) (105 1 . 9 1 ) (105 4 . 3 2 ) 1055 1051 1052 1053 1054 1056 1057 10 5 5 104 8 10 4 9 10 5 4 10 5 4 1050 1047 1048 1049 1051 1052 1055 1053 1054 10 5 0 1055 104 8 10 4 9 10 5 1 10 5 210 5 3 1054 1 0 5 5 1 0 5 6 1 0 5 7 1 0 5 8 LOT 1 COVE A T K E T T L E S T O N E PLAT 4 FIRE RISER ROOM PROPOSED BUILDING 11,890 SF T TRASH TRASH (1049.27)(1049.23) (104 5 . 9 7 ) (104 5 . 9 0 ) (1045.91) (1045.82) (1059.51) (1059.60) (105 7 . 7 1 ) (105 7 . 0 3 ) (104 9 . 4 9 ) (105 4 . 4 3 ) (105 2 . 7 0 ) 1058.20 1058.26 (1057.85) 1 0 5 4 10 5 0 10 5 1 10 5 1 10 5 1 10 5 2 10 5 2 10 5 2 10 5 3 10 5 3 10 5 3 10 5 4 1056 1057 105 5 105 2 10 5 0 . 5 8 10 5 0 . 5 0 (1 0 4 8 . 7 9 ) 1048 . 7 8 1048 . 7 1 (1 0 4 7 . 1 1 ) 1047 . 5 3 1047 . 4 6 1046 . 4 5 1046 . 3 7 1046 . 9 4 1046 . 8 3 1047 . 0 5 1046 . 8 9 1047 . 1 9 1047 . 0 3 1048 . 7 2 1048 . 8 8 1047 . 9 3 1047 . 7 5 1056.67 TC 1056.17 G 1056.31 TC 1055.81 G 1056.47 TC 1055.97 G 1057.30 TC 1056.80 G 1056.40 TC 1055.90 G 1056.14 TC 1055.64 G 1055.51 TC 1055.01 G 1053.87 TC 1053.37 G 1054.77 TC 1054.27 G 1054.90 TC 1054.40 G 1055.06 TC 1054.56 G 1054.07 TC 1053.57 G 1054.95 TC 1054.45 G 1054.30 TC 1053.80 G 1054.48 TC 1053.98 G 1054.75 TC 1054.25 G 1055.19 TC 1054.69 G 1054.87 TC 1054.37 G 1055.06 TC 1054.56 G 1055.69 TC 1055.19 G 1055.34 TC 1054.84 G 1055.08 TC 1054.58 G 1055.87 TC 1055.37 G 1056.11 TC 1055.61 G 1055 . 9 4 1056 . 0 0 10 5 5 . 2 4 10 5 4 . 8 6 1054 . 5 3 1055.23 1055.651055.47 1055.50 1053.62 (105 6 . 9 5 ) (105 6 . 6 4 ) (105 6 . 1 6 ) (105 7 . 3 8 ) (105 7 . 4 0 ) 1 0 5 5 . 5 0 1054 . 5 0 1054 . 4 3 OVERFLOW 1052.42 TC 1051.92 G 1052.74 TC 1052.24 G 1053.11 TC 1052.61 G 1053.32 TC 1052.82 G 1052.92 TC 1052.42 G 1053.29 TC 1052.79 G 1053.56 TC 1053.06 G 1054.28 TC 1053.78 G1053.72 TC 1053.22 G 10 5 5 . 5 0 10 5 5 . 5 0 10 5 5 . 8 2 10 5 5 . 8 2 10 5 6 . 0 0 10 5 6 . 0 0 1053.23 10 5 4 . 4 5 10 5 4 . 8 5 1052.57 1051.491052 . 7 8 1052 . 4 6 1052 . 9 6 1055 . 5 0 10 5 5 . 5 0 - 2 5 . 0 0 % -25. 0 0 % -31. 6 0 % - 2 0 . 1 7 % -1 7 . 4 5 % -2.72% -0.94% -2.00% -1.03% -2 . 2 9 % -1 . 0 0 % -2 . 6 9 % -0 . 8 7 % -1 . 0 0 % -2. 2 8 % -2 . 0 0 % -2 . 0 0 % -1. 0 0 % -1 . 0 0 % -3 . 0 0 % -1 . 3 6 % -2 . 8 3 % -3 . 0 0 % -3 . 0 0 % -3 . 0 0 % -1.00% -1.00% -2.80% -2.33% - 7 . 0 0 % 1056 . 0 0 1056 . 0 0 1056.60 TC 1056.10 G 1056.30 TC 1055.80 G 1054.69 TC 1054.19 G -25 . 0 0 % 105 4 1054 10 5 5 . 8 0 10 5 5 . 7 4 -3 0 . 0 0 % -1.50% -1 . 5 0 % -1.5 0 % 12.50% -2 . 0 0 % ADJUST RIM TO GRADE 100 YR ELEV: 1053.33 100 YR ELEV: 1051.55 100 YR ELEV: 1052.06 100 YR ELEV: 1053.61 WEST BASIN 100 YR ELEV= 1053.18 -2.00% 1053 . 1 0 1053.10 1053.10 1053.10 OVERFLOW 1053.87 OVERFLOW 1054.45 BASIN OVERFLOW 1054.45 1056.67 TC 1056.17 G 1055.60 1055.66 TC 1055.16 G 1056.42 TC 1055.92 G 1055.83 1056.08 TC 1055.58 G 0.8% FUTURE OVERFLOW 1051.99 CURRENT OVERFLOW 1052.25 1054.22 TC 1053.72 G V: \ P r o j e c t s \ 2 0 2 4 \ 1 2 4 . 0 6 8 7 . 0 1 \ C A D D \ S P _ 1 2 4 0 6 8 7 _ G R D G . d w g LO G A N M Y E R S , GR A D I N G P L A N , 20 2 4 / 1 0 / 0 2 , 2: 0 9 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 20 BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m KM M LJ M KS 08 - 0 6 - 2 4 20 ' 12 4 . 0 6 8 7 . 0 1 C4 0 1 124.0687.01 C401 CO V E A T K E T T L E S T O N E P L A T 4 , L O T 2 GR A D I N G P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 08 - 2 0 - 2 4 09 - 0 3 - 2 4 09 - 1 6 - 2 4 10 - 0 1 - 2 4 LJ M LJ M LJ M LJ M 1234 TT N - R R W - S S A.UTILITY WARNING: B.THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR RECORDS OBTAINED. THE SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEY FURTHER DOES NOT WARRANT THAT THE UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED. C.NOTIFY UTILITY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXISTENCE, EXACT LOCATION AND DEPTH OF ALL UTILITIES. AVOID DAMAGE TO UTILITIES AND SERVICES DURING CONSTRUCTION. ANY DAMAGE DUE TO THE CONTRACTOR'S CARELESSNESS SHALL BE CORRECTED AT THE CONTRACTOR'S EXPENSE. COORDINATE ANY UTILITY RELOCATIONS WITH UTILITY PROVIDER. D.ALL PROPOSED CONTOURS AND SPOT ELEVATIONS SHOWN ARE FINISHED GRADES AND/OR TOP OF PAVING SLAB (GUTTER), UNLESS OTHERWISE NOTED. E.ALL STORM SEWER PIPE LENGTHS ARE MEASURED FROM CENTER OF STRUCTURE TO CENTER OF STRUCTURE AND INCLUDE FLARED END SECTION. F.CONTRACTOR TO STRIP AND STOCKPILE TOPSOIL FROM ALL AREAS TO BE CUT OR FILLED. RESPREAD TO MINIMUM 8" DEPTH TO FINISH GRADES. G.THE CONTRACTOR IS RESPONSIBLE FOR CLEANING DIRT AND DEBRIS FROM STREETS, DRIVEWAYS AND SIDEWALKS CAUSED BY CONSTRUCTION ACTIVITIES BY THE END OF THE WORK DAY AND PRIOR TO A RAIN EVENT. H.SLOPES OF ALL UNPAVED AREAS TO BE 2.0% MINIMUM. I.CONTRACTOR TO CONTAIN SAWCUTTING/GRINDING SLURRY ON SITE AND DISPOSE OF ACCORDING TO IOWA DNR GENERAL PERMIT NO. 2 GRADING PLAN GENERAL NOTES T PROPOSED BUILDING 6,000 SF FFE = 1056.00 6 9 10 13 FUTURE ADDITION 4,000 SF 25' B U I L D I N G S E T B A C K 70,721 SF 1.62 AC LOT 2 C2 1055.43 1055.36 105 5 . 3 6 1055.43 1 0 5 4 . 9 5 1054.94 1 0 5 3 . 7 4 1053.69 1053 . 8 4 1053 . 9 0 1053 . 7 7 1053 . 8 3 1052.95 1052 . 9 0 10 5 2 . 9 0 1052 . 9 5 1053 . 1 5 1053 . 1 5 1053 . 2 5 1053 . 2 5 1053.07 1053 . 0 0 1055.55 TC 1055.05 G 1055.85 TC 1055.35 G 1055.84 TC 1055.34 G 1055.89 TC 1055.39 G 10 5 5 . 9 4 10 5 6 . 0 0 1055 . 9 0 1055 . 3 0 10 5 5 . 2 5 1055 . 2 0 10 5 5 . 1 5 1054 . 9 5 1055 . 0 3 1055 . 1 2 1054 . 8 6 1055 . 6 2 1054 . 1 0 1054 . 0 5 1054.00 1053 . 7 8 1053 . 7 0 10 5 4 . 0 5 10 5 5 . 7 4 10 5 5 . 7 4 10 5 5 . 8 0 10 5 5 . 8 0 1056 . 0 0 1056 . 0 0 1055.92 1055.92 1055 . 8 5 10 5 5 . 8 5 1056 . 0 0 1056 . 0 0 105 5 . 9 2 1055.92 10 5 5 . 8 5 1055 . 8 5 0 . 0 % 1.5 % 0. 0 % 1.5 % 4. 8 % 4. 9 % 1.4 % 1.8 % 1.5 % 1.0 % 1.5 % 1.1 % 1.0 % 0.0 % 1.0 % 0.0 % 3. 0 % 4. 2 % 0.0% 2. 0 % 0.0% 2. 0 % 4. 7 % 5. 3 % 1.0%1. 0 % 1.0% 1. 0 % 1. 5 % 1. 5 % 0.0% 1. 5 % 0.0% 1. 5 % 1. 5 % 1. 5 % 0.0% 1. 5 % 0.0% 1. 5 % 0.0% 0.0% 4.9% 4.8% 1. 5 % 1. 5 % 0.0% 6.7%1. 0 % 6.6% 1. 0 % 1. 0 % 1.1% 1.1% 4.6% 4.5% 1. 3 % 1.4 % 3. 0 % 3. 0 % 7.0 % 1.7 % 1.5 % 10 5 5 . 8 2 10 5 5 . 8 2 10 5 6 . 0 0 1 0 5 6 . 0 0 1055.70 TC 1055.20 G 1054 . 5 31054 . 4 8 1054 . 8 6 1054 . 7 5 1055.19 TC 1054.69 G 1. 0 % 1. 0 % 1.1 % 0.9 % 1.0% 1.0% 1.5% 1.5% 0. 9 % 1. 0 % 1. 0 % 3. 0 % 2. 8 % 1.5% 0.4% 5.0 % 5.0 % 4.8% 4.7% 7 . 9 % 8 . 1 % 1.1 % 0.8% 1055.05 V: \ P r o j e c t s \ 2 0 2 4 \ 1 2 4 . 0 6 8 7 . 0 1 \ C A D D \ S P _ 1 2 4 0 6 8 7 _ G R D G . d w g LO G A N M Y E R S , RA M P D E T A I L S , 20 2 4 / 1 0 / 0 2 , 2: 0 9 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 10 BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m KM M LJ M KS 08 - 0 6 - 2 4 10 ' 12 4 . 0 6 8 7 . 0 1 C4 0 2 124.0687.01 C402 CO V E A T K E T T L E S T O N E P L A T 4 , L O T 2 RA M P D E T A I L S WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 08 - 2 0 - 2 4 09 - 0 3 - 2 4 09 - 1 6 - 2 4 10 - 0 1 - 2 4 LJ M LJ M LJ M LJ M 1234 TT N - R R W - S S T PROPOSED BUILDING 6,000 SF FFE = 1056.00 FIRE RISER ROOM 6 9 10 13 FUTURE ADDITION 4,000 SF TR A S H F.L.=1055.15 12" RCP SE Rim=1056.95 Open NW=1055.70 F.L.=1051.45 12" RCP NW F.L.=1051.40 15" RCP SE Storm C/O=1057.18 Sanitary C/O=1057.84 F.L.=1051.12 12" RCP NW Sanitary C/O=1057.69 Rim=1048.82 F.L.=1043.62 15" RCP E F.L.=1043.62 15" RCP W Rim=1045.80 Intake=1045.13 F.L.=1041.17 15" RCP N F.L.=1041.06 15" RCP W F.L.=1040.90 15" RCP S F.L.=1041.32 15" RCP S Rim=1046.26 Intake=1045.44 F.L.=1041.54 15" RCP E F.L.=1041.47 24" RCP N F.L.=1041.18 30" RCP S Rim=1051.24 Intake=1050.37 F.L.=1047.43 15" CPP N Rim=1056.41 Inv=1042.36 8" TRUSS SW Inv=1042.36 8" TRUSS W Steel Lids Vertical Vent Gas Warning Post Steel Pole With Antenna Proposed MidAmerican Line Rip/Rap C o n c r e t e S i d e w a l k Rim=1052.27 Intake=1051.65 F.L.=1047.51 15" RCP E F.L.=1047.50 15" RCP SW C O N C R E T E CONCRETE Electric Box 10' Existing Public Utility Easement (Bk 2015, Pg 20833) 10' Existing Public Utility Easement (Bk 2019, Pg 21475) 20' Existing Storm Sewer Easement (Bk 2015, Pg 20833) Existing Public Sidewalk Easement (Bk 2019, Pg 21474) 10' Existing Sanitary Sewer Easement (Bk 2015, Pg 20833) 15' Existing Private Sanitary Sewer Easement (Bk 2022, Pg 9126) 25' B U I L D I N G S E T B A C K 1475 SE BISHOP DR SE Corner Lot 1 Coffee Bean Addition Plat 1 Found 3/4" Iron Pipe Yellow Plastic Cap #14775 S E BIS H O P DRIVE 70.00'R O W SE W A C O P L A C E / 9 8 T H S T R E E T 85 . 0 0 ' R O W N89°59'54"W 114.03' S38 ° 2 4 ' 5 9 " W 1 0 6 . 7 2 ' C 8 Existing Feeder Main Easement (Bk 2005, Pg 1875) 10' Private Water Easement 15' Private Storm Sewer Easement 70,721 SF 1.62 AC LOT 2 1 - QR 1 - GA 1 - TC 1 - TC 1 - TC 11 - PO 3 - CK3 - CK3 - SB 3 - CK 3 - SB 3 - CK 3 - SB 5 - BG 3 - CK 3 - QL 16 - PO TYP. TYP. TYP. TYP. 1 - QR 1 - CP 1 - QR 1 - CP 1 - QR 1 - CP 1 - QR 1 - CP 1 - QR 1 - QR 1 - CP 1 - QR 1 - CP 1 - QR 1 - CP 4 - GA 3 - AG 1 1 1 1 2 2 4 2 2 3 3 4 4 4 4 4 32 5 3 - PS 12 - SB 3 - CK 7 - CK 4 32 4 4 6 - TM 7 - TM V: \ P r o j e c t s \ 2 0 2 4 \ 1 2 4 . 0 6 8 7 . 0 1 \ C A D D \ S P _ 1 2 4 0 6 8 7 _ L N D . d w g LO G A N M Y E R S , PL A N T I N G P L A N , 20 2 4 / 1 0 / 0 2 , 2: 1 0 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 20 BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m KM M LJ M KS 08 - 0 6 - 2 4 20 ' 12 4 . 0 6 8 7 . 0 1 C5 0 0 124.0687.01 C500 CO V E A T K E T T L E S T O N E P L A T 4 , L O T 2 PL A N T I N G P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 08 - 2 0 - 2 4 09 - 0 3 - 2 4 09 - 1 6 - 2 4 10 - 0 1 - 2 4 LJ M LJ M LJ M LJ M 1234 TT N - R R W - S S PLANTING PLAN REQUIREMENTS (LANDSCAPE CALCULATIONS BASED UPON CITY OF WAUKEE ZONING CODE REQUIREMENTS AND THE KETTLESTONE DESIGN GUIDELINES PUD) 15% OPEN SPACE REQUIRED 70,721 SF (TOTAL LOT) x 15% = 10,608.15 SF REQUIRED (24,580 SF OR 34.75% PROVIDED) 1 OVERSTORY TREES, 0.5 UNDERSTORY TREES, AND 2 SHRUBS PER 1,000 SF OF REQUIRED OPEN SPACE. MINIMUM OF 50% OF TOTAL REQUIRED TREES SHALL BE OVERSTORY SHADE TREES. 10,608.15 / 1,000 = 10.6 PLANT UNITS (PU'S) 1 OVERSTORY TREES x 10.6 PU'S = 10.6 OVERSTORY TREES REQUIRED (11 TREES PROVIDED; 8 DECIDUOUS, 3 EVERGREEN) 0.5 UNDERSTORY TREES x 10.6 PU'S = 5.3 UNDERSTORY TREES REQUIRED (6 UNDERSTORY TREES PROVIDED) 2 SHRUB x 10.6 PU'S = 21.2 SHRUBS REQUIRED (37 OPEN SPACE SHRUBS PROVIDED) FOUNDATION PLANTINGS: FOUNDATION PLANTINGS ARE REQUIRED AT THE BASE OF ALL BUILDINGS STREET TREE REQUIREMENTS: ONE TREE FOR EVERY FORTY LINEAL FEET OF FRONTAGE ALONG THE PUBLIC STREET SHALL BE REQUIRED EXCLUSIVE OF ACCESS DRIVES. SE WACO PLACE = 220 LF 220 LF / 40 = 5.5 TREES REQUIRED. (6 PROVIDED) SE BISHOP DR = 385 LF 385 LF / 40 = 9.625 TREES REQUIRED. (10 PROVIDED) OFF-STREET PARKING AREAS: PARKING LOT ISLANDS SHALL HAVE A MINIMUM OF 1 OVERSTORY TREE. BUFFER REQUIREMENT: THERE ARE NO BUFFER REQUIREMENTS. MINIMUM HEIGHT REQUIREMENTS : DECIDUOUS OVERSTORY TREES SHALL BE A MINIMUM OF 8' IN HEIGHT. EVERGREEN OVERSTORY TREES SHALL BE A MINIMUM OF 6' IN HEIGHT. DECIDUOUS ORNAMENTAL TREES SHALL BE A MINIMUM OF 6' IN HEIGHT. MINIMUM QUANTITIES: A MINIMUM OF FIFTY PERCENT (50%) OF ALL REQUIRED TREES SHALL BE OVERSTORY SHADE TREES. A MINIMUM OF TWENTY-FIVE (25%) OF ALL REQUIRED TREES SHALL BE EVERGREENS. A MINIMUM OF 1.0 OVERSTORY TREES, 0.5 UNDERSTORY TREES AND TWO (2) SHRUBS FOR EVERY 1,000 SF OF REQUIRED OPEN SPACE SHALL BE INSTALLED. FOUNDATION PLANTINGS ARE REQUIRED AT THE BASE OF ALL BUILDINGS. FOUNDATION PLANTINGS MAY INCLUDE SHRUBS, ORNAMENTAL GRASSES, PERENNIALS, AND GROUND COVERS. NOTE: QUANTITIES SHOWN ARE APPROXIMATE. CONTRACTOR TO VERIFY PLANT MATERIAL PRIOR TO BIDDING. IN THE CASE OF A DISCREPANCY, THE PLAN QUANTITY SHALL GOVERN. CODE QTY BOTANICAL NAME COMMON NAME SIZE TYPE ORNAMENTAL TREES AG 3 Amelanchier x grandiflora 'Autumn Brilliance'Autumn Brilliance Apple Serviceberry 1.5" Cal.B&B QL 3 Quercus robur x bicolor 'Long'Regal Prince® Oak 1.5" Cal.B&B CONIFERS PS 3 Pinus strobus White Pine 6` Ht.B&B SHADE TREES CP 7 Celtis occidentalis 'Prairie Pride'Prairie Pride Hackberry 1.5" Cal.B&B GA 5 Ginkgo biloba 'Autumn Gold'Autumn Gold Maidenhair Tree 1.5" Cal.B&B QR 9 Quercus rubra Red Oak 1.5" Cal.B&B TC 3 Tilia cordata Littleleaf Linden 1.5" Cal.B&B CODE QTY BOTANICAL NAME COMMON NAME SIZE CONTAINER SHRUBS BG 5 Buxus x 'Green Gem'Green Gem Boxwood 3 gal.Pot PO 27 Physocarpus opulifolius 'Donna May' TM Little Devil Dwarf Ninebark 3 gal.Pot SB 21 Spiraea betulifolia 'Tor Gold' TM Glow Girl Birchleaf Spirea 3 gal.Pot TM 13 Thuja occidentalis 'Gold Drop'Gold Drop Arborvitae 4" Plug GRASSES CK 25 Calamagrostis x acutiflora 'Karl Foerster'Karl Foerster Feather Reed Grass 1 gal.Pot PLANT SCHEDULE PLANTING PLAN GENERAL NOTES A.UTILITY WARNING: THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR RECORDS OBTAINED. THE SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEY FURTHER DOES NOT WARRANT THAT THE UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED. B.NOTIFY UTILITY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXISTENCE, EXACT LOCATION AND DEPTH OF ALL UTILITIES. AVOID DAMAGE TO UTILITIES AND SERVICES DURING CONSTRUCTION. ANY DAMAGE DUE TO THE CONTRACTOR'S CARELESSNESS SHALL BE CORRECTED AT THE CONTRACTOR'S EXPENSE. COORDINATE AND COOPERATE WITH UTILITY COMPANIES DURING CONSTRUCTION. C.ALL PLANT MATERIAL SHALL AT LEAST MEET MINIMUM REQUIREMENTS SHOWN IN THE "AMERICAN STANDARDS FOR NURSERY STOCK" (ANSI Z60.1-LATEST EDITION). D.CONTRACTOR SHALL GUARANTEE ALL PLANT MATERIAL FOR A PERIOD OF ONE YEAR FROM DATE OF INSTALLATION. PLANTING PLAN CONSTRUCTION NOTES 1.PROVIDE 3-INCH DEPTH SHREDDED HARDWOOD MULCH IN A MIN 3-FOOT PERIMETER RING AROUND ALL TREES. PROVIDE VERTICAL CUT NATURAL EDGE TO A DEPTH OF 4-INCHES. 2.PROVIDE 3-INCH DEPTH SHREDDED HARDWOOD MULCH IN PLANT BED AREAS AS INDICATED ON PLAN. 3.PROVIDE 3/16" BLACK STEEL EDGER WITH STAKES. 4.SOD ALL AREAS DISTURBED BY CONSTRUCTION ON SITE INCLUDING ROW UNLESS NOTED OTHERWISE. 5.PROVIDE DETENTION BASIN SEED MIX AS PROVIDED BY PRAIRIE MOON NURSERY. WWW.PRAIRIEMOON.COM, 32115 PRAIRIE LANE, WINONA, MN 55987, OR APPROVED EQUAL SEEDING RATE: 11.48 LBS/ACRE. INSTALL AS PER SUDAS SPECIFICATIONS 9010 SEEDING. PROVIDE REGREEN, TRICITUM AESTIVUM, SHORT-LIVED STERILE PERENNIAL WHEAT/WHEAT GRASS HYBRID OR APPROVED EQUAL. APPLY AT 30 LBS/ACRE. 6.PROVIDE MECHANICALLY-BONDED FIBER MATRIX IMMEDIATELY FOLLOWING SEED APPLICATION ON ALL AREAS SEEDED WITH A SLOPE OF 6:1 OR GREATER. ACCEPTABLE PRODUCTS AND MANUFACTURERS: PROFILE PRODUCTS LLC., 750 LAKE COOK ROAD - SUITE 400 BUFFALO GROVE, IL 60089 P: 1-900-366-1180 WWW.PROFILEPRODUCTS.COM OR APPROVED EQUAL. V: \ P r o j e c t s \ 2 0 2 4 \ 1 2 4 . 0 6 8 7 . 0 1 \ C A D D \ S P _ 1 2 4 0 6 8 7 _ T S H . d w g LO G A N M Y E R S , SI T E D E T A I L S , 20 2 4 / 1 0 / 0 2 , 2: 1 0 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m KM M LJ M KS 08 - 0 6 - 2 4 ## # ' 12 4 . 0 6 8 7 . 0 1 C6 0 0 124.0687.01 C600 CO V E A T K E T T L E S T O N E P L A T 4 , L O T 2 SI T E D E T A I L S WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 08 - 2 0 - 2 4 09 - 0 3 - 2 4 09 - 1 6 - 2 4 10 - 0 1 - 2 4 LJ M LJ M LJ M LJ M 1234 TT N - R R W - S S ST-5A: SEE SHEET C300 FOR INVERTS ST-7: SEE DETAIL 1/C602 FOR MORE INFORMATION 18" X 18" TOP MANIFOLD PROVIDE 9" OF DEPTH FOR STONE V: \ P r o j e c t s \ 2 0 2 4 \ 1 2 4 . 0 6 8 7 . 0 1 \ C A D D \ S P _ 1 2 4 0 6 8 7 _ T S H . d w g LO G A N M Y E R S , SI T E D E T A I L S , 20 2 4 / 1 0 / 0 2 , 2: 1 0 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m KM M LJ M KS 08 - 0 6 - 2 4 ## # ' 12 4 . 0 6 8 7 . 0 1 C6 0 1 124.0687.01 C601 CO V E A T K E T T L E S T O N E P L A T 4 , L O T 2 SI T E D E T A I L S WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 08 - 2 0 - 2 4 09 - 0 3 - 2 4 09 - 1 6 - 2 4 10 - 0 1 - 2 4 LJ M LJ M LJ M LJ M 1234 TT N - R R W - S S 1 C601 ST-7: OUTLET STRUCTURE DETAIL NO SCALE PROFILE VIEW 30" 15" OUTLET PIPE INV=1041.32 ACCESS MANHOLE RIM=1051.64 BOTTOM OF BASIN ELEV=1041.32 TOP OF STAINLESS STEELWEIR ELEV=1044.00 PLAN VIEW 18" X 18" TOP MANIFOLD ELEV=1044.60 3" ORIFICE INV: 1041.40 6" PERFORATED SUBDRAIN INV=1041.40 BOTTOM OF BASIN ELEV=1041.40 6" SUBDRAIN INV: 1041.40 18" X 18" TOP MANIFOLD INV: 1044.60 STAINLESS STEAL WEIR W/ 3" ORIFICE TOP OF WEIR ELEVATION: 1044.00 15" RCP OUTLET PIPE INV: 1041.32 18" X 18" BOTTOM MANIFOLD INV: 1042.31 18" X 18" BOTTOM MANIFOLD ELEV=1042.31 STONE - ARRISCRAFT SHADOW STONE AVALANCHE BRICK - ARRISCRAFT ARCHITECTURAL LINEAR MIDNIGHT GRAY STOREFRONT - CLEAR ANODIZED ALUMINUM CEMENT BOARD SIDING - NICHIHA VINTAGEWOOD - REDWOOD ILLUMINATION - RUSSET EXTERIOR ELEVATIONS SOUTH ELEVATION A2.1 1 NORTH ELEVATION A2.1 4 WEST ELEVATION A2.1 2 EAST ELEVATION A2.1 3 A2.1 Ke t t l e s t o n e S u p e r m a r k e t Co n t r a c t D o c u m e n t s Wa u k e e , I o w a 5 0 2 6 3 240048JOB NO. TITLE SHEETFL O O R P L A N F O R S I T E P L A N R E V I E W 9 - 1 7 - 2 0 2 4 TRASH ENCLOSURE TRASH ENCLOSURE A2.2 1 A2.2 Ke t t l e s t o n e S u p e r m a r k e t Co n t r a c t D o c u m e n t s Wa u k e e , I o w a 5 0 2 6 3 240048JOB NO. TITLE SHEET FL O O R P L A N F O R S I T E P L A N R E V I E W 8 - 6 - 2 0 2 4 TRASH ENCLOSURE A2.2 2 TRASH ENCLOSURE A2.2 3