HomeMy WebLinkAbout2025-08-11 D01A-C Interstate Crossing_Final Plat, Construction Drawings, Site Plan AGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: August 11, 2025 AGENDA ITEM: Consideration of approval of resolutions approving Construction Drawings for Interstate Crossing, Final Plat for Interstate Crossing, and Site Plan for Lot 1, Interstate Crossing (555 Interstate Parkway) FORMAT: Resolutions SYNOPSIS INCLUDING PRO & CON: The applicant is requesting approval of construction drawings, a final plat, and site plan for a commercial development, located in the northwest corner where Interstate Parkway and Ute Avenue intersect, containing 1.8-acres. The project includes the construction of one single-story building with up to 10 tenant spaces for a flex use warehouse building. The building is 16,200 square feet in area and 25’-8” in height. The proposed project includes a final plat to combine two parcels into 1 lot for this commercial development. Access to the proposed site is off Interstate Parkway. Parking for the site is located south of the building facing Interstate Parkway. A total of 25 parking spaces are required for the proposed use and building. The site plan shows 48 parking stalls are being provided with two accessible spaces. A five-foot wide sidewalk will extend an existing sidewalk located in the southwest corner of the site and extend easterly along the front of the site north of Interstate Parkway. Public utilities for this site will include water and sanitary sewer. All other utilities will be private. There will be a short extension of public water main and sanitary sewer to the north side of the plat. Storm water detention will be provided in an above ground detention pond with two bioswales located in the southwest corner of the site, which will be privately owned and maintained. A minimum of 15% of the site is required to be open space, they are providing 41%. The required amount of plantings are being provided throughout the site in compliance with the Landscape and Open Space Ordinance. The elevations of the buildings will be constructed of painted Hardie and metal panels with steel doors along the rear. Additional materials include stone and brick accents and storefront glazing. The trash enclosure will be constructed of brick walls and steel gates to match the building. D1A-C A photometric plan was submitted and found to comply with the requirements of the Site Plan Ordinance. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning Commission reviewed the final plat and site plan request at their meeting on June 24, 2025, and recommended approval: Approval of a Final Plat for Interstate Crossing and Site Plan for Lot I, Interstate Crossing (555 Interstate Parkway) Elizabeth Cramblet, City Planner, introduced the request for approval of a site plan and final plat for a commercial building with 10 tenant spaces, as requested by Robin Sobatka/Paramount Land Company, represented by Lance Burke of Pelds Design Services. The property is generally located north of Interstate Parkway and west of Ute Avenue. The site currently includes two parcels. Both parcels were recently rezoned to M-I (Light Industrial). The south parcel is a platted lot within the I-80 West Industrial Park Plat. The north parcel is an unplatted parcel. The applicant wishes to combine these two lots into one lot, to allow for the use of a flex use warehouse building. The project includes construction of a single-story building that will include up to 10 tenant spaces for use as a flex use warehouse building. The building is 16,200 square feet in area and 25-foot 8-inches in height. A trash enclosure is provided at the west side of the site next to the building. A five-foot wide sidewalk will extend from an existing sidewalk located in the southwest corner of the site and extend easterly along the front of the site north of Interstate Parkway. A connecting walkway will extend from this new sidewalk to the parking lot on the east side of the proposed driveway. This walkway will connect to the front of the building where entrances will be located. Public utilities for this site will include water and sanitary sewer. All other utilities will be private. Storm water detention will be provided in an above ground retention pond with two bioswales located in the southwest corner of the site, which will be privately owned and maintained. A minimum of 15% of the project area is required to be open space. The total amount of open space proposed is approximately 41%. Trees will be installed in the parking lot to the south. Additional trees and shrubs will be planted to the north side of the property. The landscape plan is in conformance with the Landscape and Open Space Ordinance. The elevations indicate the building will be constructed of painted Hardie and metal panels with steel doors along the rear. Additional materials include stone and brick accents and storefront glazing. The trash enclosure will be constructed of brick walls and steel gates to match the proposed building. A photometric plan for the site lighting has not yet been submitted. Once submitted, it will need to comply with the requirements of the Site Plan Ordinance prior to City Council review. The site plan is in general conformance with the Zoning Ordinance, Site Plan Ordinance and Comprehensive Plan. Staff recommends approval of the Final Plat for Interstate Crossing and Site Plan for Lot I, Interstate Crossing subject to any remaining staff comments, and review of legal documents. Discussion as follows: • Request for clarification on why the photometric plan has not been submitted; Andy confirmed the effort to keep the project moving forward and take advantage of upcoming council meeting dates, but also confirmed this item will not be presented to City Council until the lighting plan has been submitted and approved Motion by Commissioner Bankole for approval of a Final Plat for Interstate Crossing, seconded by Commissioner Lohse. Ayes: Broderick, Bankole, Beenken, Lohse, and Tuel. Nays: None. Motion carried. Motion by Commissioner Broderick for approval of a Site Plan for Lot I, Interstate Crossing (555 Interstate Parkway), seconded by Commissioner Tuel. Ayes: Broderick, Bankole, Beenken, Lohse, and Tuel. Nays: None. Motion carried. RECOMMENDATION: Approve the resolutions. ATTACHMENTS: I. Proposed Resolutions II. Staff Report III. Site Plan & Public Improvement Plans IV. Final Plat V. Building Elevations PREPARED BY: Andy Kass, Community Development Director REVIEWED BY: PUBLIC NOTICE INFORMATION – NAME OF PUBLICATION: DATE OF PUBLICATION: THE CITY OF WAUKEE, IOWA RESOLUTION 2025- APPROVING THE CONSTRUCTION DRAWINGS FOR INTERSTATE CROSSING IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, construction drawings have been submitted to the City for Interstate Crossing; AND, WHEREAS, the construction drawings have been reviewed by the City Engineer and City staff, and are found to be in general conformance with section §177 – Subdivision Regulations – Design Standards of the Waukee Municipal Code; AND, NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 11th day of August, 2025, that the Construction Drawings for Interstate Crossing be approved. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN R. Charles Bottenberg Chris Crone Rob Grove Anna Bergman Pierce Ben Sinclair THE CITY OF WAUKEE, IOWA RESOLUTION 2025- APPROVING THE FINAL PLAT FOR INTERSTATE CROSSING IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, 555 Interstate Partners, LLC, has requested final plat approval of Interstate Crossing Final Plat (the “Plat”); AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Plat on June 24, 2025, subject to remaining staff comments and review of the legal documents; AND, WHEREAS, the Final Plat for Interstate Crossing and the documents relating thereto will comply with section §176 – Subdivision Regulations of the Waukee Municipal Code. NOW, THEREFORE, BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 11th day of August, 2025, that the Final Plat for Interstate Crossing be and the same is hereby accepted and approved by the City Council of the City of Waukee. BE IT FURTHER RESOLVED that the City of Waukee does hereby accept the following easements and documents to be filed with the Plat: 1. Public Utility Easement; 2. Public Storm Water Detention Easement ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN R. Charles Bottenberg Chris Crone Rob Grove Anna Bergman Pierce Ben Sinclair THE CITY OF WAUKEE, IOWA RESOLUTION 2025- APPROVING THE SITE PLAN FOR LOT 1, INTERSTATE CROSSING (555 INTERSTATE PARKWAY) IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Site Plan for Lot 1, Interstate Crossing, subject to remaining staff comments on June 24, 2025; AND, WHEREAS, the Site Plan for Lot 1, Interstate Crossing is in general conformance with §160 – Site and Building Development Standards Ordinance of the Waukee Municipal Code; AND, WHEREAS, the Site Plan for Lot 1, Interstate Crossing is in general conformance with §161 – Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND, NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 11th day of August, 2025, that the Site Plan for Lot 1, Interstate Crossing is approved subject to remaining staff comments. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN R. Charles Bottenberg Chris Crone Rob Grove Anna Bergman Pierce Ben Sinclair PLANNING AND ZONING COMMISSION STAFF REPORT PROJECT: Interstate Crossing (Final Plat) and Lot 1, Interstate Crossing (Site Plan) PREPARED BY: Elizabeth Cramblet – Planner REPORT DATE: June 20, 2025 MEETING DATE: June 24, 2025 GENERAL INFORMATION Owner/Applicant: Robin Sobatka / Paramount Land Company Owner’s Representative: Lance Burke, Pelds Design Services Request: The applicant is requesting approval of a site plan and final plat for a commercial building with 10 tenant spaces. Location and Size: Property is generally located north of Interstate Parkway and west of Ute Avenue, containing approximately 1.8 acres (78,375 square feet). Property Address: 555 Interstate Parkway AREA MAP ABOVE: Aerial of subject property (outlined in RED) in relation to the surrounding area. June 20, 2025 2 of 3 LAND USES AND ZONING Location Existing Land Use Comprehensive Plan Current Zoning Property in Question Vacant - Undeveloped Light Industrial Office M-1 (Light Industrial District) North Developed – Real Estate Building Dallas County Dallas County Zoning South Vacant – Undeveloped Light Industrial Office C-1 (Community and Highway Service Commercial District) East Vacant – Undeveloped Dallas County Dallas County Zoning West Developed – Parking Lot Light Industrial Office M-1 (Light Industrial District) BACKGROUND AND LOTS The property is generally located north of Interstate Parkway and west of Ute Avenue. The site currently includes two parcels. Both parcels were recently rezoned to M-1 (Light Industrial Park). The south parcel is a platted lot (Lot 6) within the I-80 West Industrial Park Plat. The north parcel is an unplatted parcel. The applicant wishes to combine these two lots into one lot, to allow for the use of a flex use warehouse building. PROJECT DESCRIPTION The project includes the construction of a single-story building that will include up to ten tenant spaces for flex use warehouse building. The building is 16,200 square feet in area and 25’-8” in height. A trash enclosure is provided at the west side of the site next to the building. ACCESS AND PARKING Access to the proposed site is off Interstate Parkway. Parking for the site is located south of the building facing Interstate Parkway. Based on a warehouse use, A total of 25 parking spaces are required for the proposed site plan. A total of 48 stalls are being provided, including 2 accessible spaces. A Five-foot wide sidewalk will extend an existing sidewalk located in the southwest corner of the site and extend easterly along the front of the site north of Interstate Parkway. A connecting walkway will extend from this new sidewalk to the parking lot on the east side of the proposed driveway. This walkway will connect to the front of the building where entrances will be located. UTILITIES Public utilities for this site will include water and sanitary sewer. All other utilities will be private. Storm water detention will be provided in an above ground detention pond with two bioswales located in the southwest corner of the site, which will be privately owned and maintained. LANDSCAPING & OPEN SPACE A minimum of 15% of the project area is required to be open space. The total amount of open space proposed is approximately 41%. Trees will be installed in the parking lot to the south. Additional trees and shrubs will be planted to the north side of the property. The proposed landscape plan is in conformance with the Landscape and Open Space Ordinance. June 20, 2025 3 of 3 ELEVATIONS The elevations indicate the building will be constructed of painted Hardie and metal panels with steel doors along the rear. Additional materials include stone and brick accents and storefront glazing. Elevations of the proposed building have been provided for review. The trash enclosure will be constructed of brick walls and steel gates to match the proposed building. PHOTOMETRIC PLAN A photometric plan for the site lighting has not yet been submitted. Once submitted it will need to comply with the requirements of the Site Plan Ordinance prior to City Council review. COMPREHENSIVE PLAN The land uses shown within the Comprehensive Plan for the subject property are Light Industrial Office. The Comprehensive Plan allows for flexibility of land uses including flex space, storage or distribution of goods or products. STAFF RECOMMENDATION The site plan is in general conformance with the Zoning Ordinance, Site Plan Ordinance , and Comprehensive Plan. Staff recommends approval of the Final Plat for Interstate Crossing and Site Plan for Lot 1, Interstate Crossing subject to any remaining staff comments and review of legal documents. PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 VICINITY MAP N.T.S SITE PLAN FOR LOT 1, INTERSTATE CROSSING 555 INTERSTATE PARKWAY WAUKEE, IOWA C-001 - COVER SHEET C-002 - NOTE SHEET C-003 - TOPO SHEET C-100 - DEMO SHEET C-101 - LAYOUT SHEET C-103 - DIMENSION SHEET C-201 - GRADING SHEET C-301 - UTILITY SHEET C-401 - EROSION CONTROL SHEET C-601 - DETAIL SHEET C-602 - UTILITY EXTENSION PROFILE SHEET C-701 - LANDSCAPING SHEET SHEET INDEX Parcel 20-79 as shown in the Retracement Plat of Survey filed December 18, 2020, in Book 2020, Page 35993 of the Dallas County Recorder's Office. and Lot 6 in I-80 West Industrial Park Plat 1, on Official Plat, now included in and forming a part of the City of Waukee, Dallas County, Iowa; TO BE KNOWN AS: LOT 1, INTERSTATE CROSSING C-001 - C-701 SITE ADDRESS 555 INTERSTATE PARKWAY WAUKEE, IOWA 50263 SITE AREA 1.8 ACRES (78,375 SQ.FT.) ZONING SITE: M-1: LIGHT INDUSTRIAL DISTRICT NORTH (DALLAS COUNTY): C-2: HIGHWAY SERVICE & AGRICULTURAL RELATED COMMERCIAL DISTRICT EAST (DALLAS COUNTY): C-2: HIGHWAY SERVICE & AGRICULTURAL RELATED COMMERCIAL DISTRICT SOUTH: C-1: COMMUNITY AND HIGHWAY SERVICE COMMERCIAL DISTRICT WEST: M-1: LIGHT INDUSTRIAL DISTRICT SETBACKS FRONT SETBACK (SOUTH AND EAST PROPERTY LINE): 30 FT SIDE SETBACK (WEST PROPERTY LINE): 30 FT REAR SETBACK (NORTH PROPERTY LINE): 30 FT BUILDINGS EXISTING:NONE PROPOSED:~ 270'-0" x 60'-0" - 16,200 SQ.FT. BUILDING USES MAJOR USE CLASSIFICATIONS: A-2 ASSEMBLY B BUSINESS M MERCHANTILE BUILDING HEIGHT MAX BUILDING HEIGHT:40' PROPOSED HEIGHT:25'-8" OPEN SPACE PROPOSED:41% (32,195 SQ.FT.) REQUIRED:15% (11,756 SQ. FT.) IMPERVIOUS SPACE PROPOSED:59% (46,180 SQ.FT.) PARKING REQUIRED: 1.5 SPACE PER 1000 SQ. FT. OF GROSS FLOOR AREA (16,200 / 1000 * 1.5 = 25 SPACES REQUIRED) PROPOSED: 48 SPACES (INCLUDING 2 HANDICAP PARKING STALL) *FUTURE TENANTS MAY BE LIMITED IF PARKING ISN'T ADEQUATE. PLEASE REFER TO THE TABLE IN SECTION 168.10 OF THE CITY CODE FOR THE MINIMUM NUMBER OF PARKING SPACES REQUIRED FOR TYPE OF USE. DISTURBED AREAS ESTIMATED:86,890 SQ.FT. ALL DISTURBED AREAS, INCLUDING THE R.O.W., SHALL BE SODDED. THE DISTURBED AREA FOR THIS SITE IS GREATER THAN 1 ACRE, THEREFORE AN IOWA NPDES PERMIT #2 AND CITY OF WAUKEE COSESCO PERMIT IS REQUIRED. FLOODPLAIN PER FEMA MAP #19049C0342G, THE SITE IS LOCATED IN ZONE X, AREA OF MINIMAL FLOOD HAZARD FAA PER FAA NOTICE CRITERIA TOOL, SITE DOES NOT EXCEED NOTICE CRITERIA UP TO 100 FT HEIGHT (FOR POSSIBLE CRANE HEIGHT) THEREFORE FILING WITH THE FAA IS NOT REQUIRED. IOWA ONECALL CONTACT LIST OWNER ROBIN SOBATKA 36406 SHAGBARK CIRCLE VAN METER, IOWA 50261 PROJECT CONTACT: ROBIN SOBATKA PHONE: (515) 250-3145 EMAIL: ROBIN5SOBOT@GMAIL.COM DEVELOPER PARAMOUNT LAND COMPANY 2540 73RD STREET URBANDALE, IOWA 50322 PROJECT CONTACT: SASI KARUTURI PHONE: (515) 333-1954 EMAIL: SASI@PARAMOUNTLANDIA.COM CITY CONTACT CITY OF WAUKEE 204 HICKMAN ROAD WAUKEE, IOWA 50325 PROJECT CONTACT: MELISSA DEBOER PHONE: (515) 978-7898 EMAIL: MDEBOER@WAUKEE.ORG ENGINEER/ LAND SURVEYOR PELDS DESIGN SERVICES 2323 DIXON ST DES MOINES, IOWA 50316 PROJECT CONTACT: ELARA JONDLE PHONE: (515) 265-8196 EMAIL: ELARA@PELDS.COM ARCHITECT PELDS DESIGN SERVICES 2323 DIXON ST DES MOINES, IOWA 50316 PROJECT CONTACT: DANIEL WILRICH PHONE: (515) 265-8196 EMAIL: DANIEL@PELDS.COM LEGAL DESCRIPTION: REVISIONS:LEGEND: MORE OR LESS GUTTER ELEVATION TOP OF CURB ELEVATION +/- EXISTING/ PROPOSED ELEVATION 123.45G 123.45TC FLOWLINE ELEVATIONFL FINISHED FLOORF.F. 123.45123.45/ CALCULATED CORNER FOUND CORNER CONTROL POINT ELEC. TRANSFORMER ELEC. METER ELEC. BOX SIGN PARKING SPACE STREET LIGHT POWER POLE LIGHT POLE CALCULATED SECTION CORNER FOUND SECTION CORNER AREA LIGHT GUY ANCHOR ELEC. MANHOLE ELEC. VAULT GAS VALVE GAS METER UTILITY PEDESTAL CABLE TV JUNCTION BOX SANITARY SEWER MANHOLE STORM SEWER MANHOLE CLEANOUT DOWNSPOUTD SINGLE INTAKE WATER VALVE WATER TEE FLARED END SECTION FIRE HYDRANT VALVE PROPOSED UTILITY LINEP XX EXISTING UTILITY LINEE XX WATER METER THROAT INTAKE FENCE LINE FIBER OPTIC WATER GAS LINE SANITARY SEWER STORM SEWER UNDERGROUND TEL. OVERHEAD TEL. W ST UGT OHT G SAN UNDERGROUND ELEC.UGE OVERHEAD ELEC.OHE FO CABLE TELEVISIONCATV AREA INTAKE BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: C-001 - COVER SHEET 08.07.2025 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: L. BURKE J:\2025 Projects\25-010 I80 WIP Plat 1 Lot 6\Engineering\Sheet Set WAUKEE, IOWA LOT 1, INTERSTATE CROSSING 555 INTERSTATE PARKWAY TITLE: ----25-010 PRELIMINARY ( CTLIA01 ) CENTURYLINK Company name : CENTURYLINK Design contact: SADIE HULL Phone: 9185470147 Email: sadie.hull@lumen.com ( DALLIA1 ) MEDIACOM Company name : MEDIACOM Design contact: DAVE MEYERS Phone: 5159917388 Email: DMEYERS2@MEDIACOMCC.COM ( M28E ) MIDAMER-ELEC Company name : MIDAMER-ELEC Design contact: BRIAN SEWELL Phone: 5155745042 Email: mecdsmdesignlocates@midamerican.com ( MIFI ) MI-FIBER Company name : MI-FIBER Design contact: JUSTIN MILLER Phone: 5158978802 Email: jmiller@mi-fiber.net ( UPN ) UNITE PRIVATE NETWORKS, LLC Company name : UNITE PRIVATE NETWORKS, LLC Design contact: Joe Kilzer Phone: 8164253556 Email: upngis@upnfiber.com ( WDM ) WEST DES MOINES WATER WORKS Company name : WEST DES MOINES WATER WORKS Design contact: William Mabuce Phone: 5152223510 Email: design_locates@wdmww.com ( WKE ) WAUKEE, CITY OF Company name : WAUKEE, CITY OF Design contact: Tim Royer Phone: 5159874363 Email: troyer@waukee.org ( XR1 ) XENIA RURAL WATER DISTRICT Company name : XENIA RURAL WATER DISTRICT Design contact: Laird Van Dee Phone: 5156762117 Email: lvandee@xeniawater.org ( XRW ) XENIA RURAL WATER DISTRICT Company name : XENIA RURAL WATER DISTRICT Design contact: Laird Van Dee Phone: 5156762117 Email: lvandee@xeniawater.org PROJECT CONTACTS © 2025 PELDS DESIGN SERVICES THESE DOCUMENTS HAVE BEEN PREPARED SPECIFICALLY FOR THE ABOVE REFERENCED PROJECT. THEY ARE NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF PELDS DESIGN SERVICES LLC. REPRODUCTION IS PROHIBTED SITE LOCATION                 NOTE TO CONTRACTORS: ITEM QUANTITY INFORMATION*UNITS 6” CONCRETE PAVEMENT ON-SITE: 27,294 - OFF-SITE: 0 SQ. FT. 7” CONCRETE PAVEMENT ON-SITE/APPROACHES: 782 - OFF-SITE: NONE SQ. FT. CONCRETE CURB 1,170 LIN. FT. SIDEWALKS 4,821 SQ. FT. DETENTION 4,872 CU. FT. SANITARY SEWER SERVICE - 6" PVC DIRECT BURY: 59 - BORE: NONE LIN. FT. SANITARY SEWER EXTENSION - 8" PVC DIRECT BURY: 71 - BORE:NONE LIN. FT. WATER SERVICE - 6" HDPE DIRECT BURY: 155 - BORE:NONE LIN. FT. WATER MAIN EXTENSION - 12" HDPE DIRECT BURY: 69 - BORE:NONE LIN. FT. GAS SERVICE DIRECT BURY: 78 - BORE: NONE LIN. FT. 6" HDPE STORM SERVICE 147 LIN. FT. 12" HDPE STORM SERVICE 429 LIN. FT. 15" HDPE STORM SERVICE 253 LIN. FT. 15" RCP STORM SEWER MAIN 30 LIN. FT. STRUCTURES - SANITARY CLEANOUT 1 EACH STRUCTURES - 48" SW-501 6 EACH STRUCTURES - 92" SW-505 2 EACH STRUCTURES - SW-401 2 EACH STRUCTURES - SW-512 2 EACH STRUCTURES - FES 2 EACH EARTHWORK CUT 5,603 CU. YD. EARTHWORK FILL 1,726 CU. YD. TOPSOIL REQUIRED 782 CU. YD. SOD AREA 42,214 SQ. FT. CONCRETE CURB DEMOLITION (GRIND)71.03 LIN. FT. *IN THE EVENT OF A DISCREPANCY BETWEEN THE QUANTITY ESTIMATES AND THE DETAILED PLANS, THE DETAILED PLANS SHALL GOVERN* *CONTRACTOR TO PROVIDE A COMPLETE PROJECT PER THE CONSTRUCTION DOCUMENTS, QUANTITIES PROVIDED AS PART OF THIS SUMMARY ARE FOR REFERENCE PURPOSES ONLY AND ARE NOT A BASIS FOR CHANGE ORDER IF ADDITIONAL QUANTITY IS INSTALLED AS PART OF THE ORIGINAL BID DOCUMENTS* *EARTHWORK VALUES ARE TO FINISH GRADE. CONTRACTOR SHALL BE RESPONSIBLE FOR EXACT QUANTITIES I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF IOWA. _______________________________________________________ VOLDEMARS L. PELDS, P.E. IA. LIC. NO. 18842 DATE MY LICENSE RENEWAL DATE IS DECEMBER 31, 2025 ADDITIONAL PAGES OR SHEETS COVERED BY THIS SEAL (NONE UNLESS INDICATED HERE):_________________________________ ________________________________________________________ VOLDEMARS L. 18842 PELDS IOWA PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 FOR LOT 1, INTERSTATE CROSSING 555 INTERSTATE PARKWAY WAUKEE, IOWA PAVING NOTES 1.THE PAVING/ GRADING CONTRACTOR SHALL BACKFILL THE PAVING SLAB AND FINE GRADE THE RIGHT OF WAY AS SOON AFTER THE PAVING AS POSSIBLE. ALL ROW AREAS SHALL BE SODDED IN ACCORDANCE WITH THE LOCAL JURISDICTION SPECIFICATIONS AND THE LATEST VERSION OF SUDAS. 2.SEE DETAILS FOR ALL PAVEMENT THICKNESS. 3.DETECTABLE WARNING PANEL(S) CALLED OUT ON PLANS SHALL BE PER A.D.A. REGULATIONS. PANEL TYPE & COLOR SHALL BE PER CITY STANDARD. 4.SIDEWALKS SHALL HAVE EXPANSION JOINTS AT 100 FOOT INTERVALS AS REQUIRED BY CITY CODE 5.ALL WALKS, PARKING LOTS, HANDICAP PARKING, RAMPS, ETC. SHALL COMPLY WITH ALL A.D.A. AND CITY CODES. HANDICAP PARKING SIGNAGE IS REQUIRED FOR ALL HANDICAP STALLS AND SHALL BE CONSIDERED INCIDENTAL. IN EVENT OF A DISCREPANCY BETWEEN THE PLANS AND THE A.D.A./CITY CODES THE A.D.A./CITY CODES SHALL GOVERN. CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING A.D.A. CODES ARE MET. PAVEMENT SAWCUT NOTES 1.CONTRACTOR TO PROVIDE SAWCUT JOINTING PLAN PRIOR TO ANY CONCRETE PAVEMENT INSTALLATION. 2.PAVEMENT MAY BE REQUIRED TO BE REMOVED AND REPLACED IF PLACED WITHOUT AN APPROVED PLAN. 3.LONGITUDINAL JOINTS IN DRIVE LANES & THE OUTER MOST JOINT OF ALL PARKING AREAS SHALL BE SUDAS TYPE 'L-1' OR 'L-2' JOINTS AND HAVE STEEL. INTERIOR PARKING LOT JOINTS, OTHER THAN THE OUTER MOST JOINT, DO NOT NEED STEEL AND SHALL BE SUDAS TYPE 'B' OR TYPE 'K' JOINTS. ALL TRANSVERSE JOINTS SHALL BE SUDAS TYPE 'C' OR TYPE 'DW' JOINTS WITH STEEL IN THE CASE OF A DAY'S WORK JOINT. SOIL NOTES 1.STRIP AND STOCKPILE TOPSOIL TO BE RESPREAD. GRADING CONTRACTOR SHALL STOCKPILE TOPSOIL FOR SHOULDERING. 2.SOD REQUIREMENT PER SUDAS: IN AREAS WHERE TOPSOIL HAS BEEN STRIPPED, A SODBED SHOULD BE CONSTRUCTED BY SPREADING A MINIMUM OF 6 INCHES OF TOPSOIL PRIOR TO SODDING. DEEPER TOPSOIL DEPTHS (8 TO12 INCHES OR GREATER) ARE DESIRABLE AS THEY INCREASE THE ORGANIC MATTER AVAILABLE FOR USE BY THE PLANTS, ALLOW FOR DEEPER ROOT PENETRATION AND INCREASE THE MOISTURE HOLDING ABILITY OF THE SOIL. 3.PERMANENT SEED REQUIREMENT PER SUDAS: IN ORDER TO PROVIDE AN ADEQUATE GROWING MEDIUM, A MINIMUM OF 8 INCHES OF TOPSOIL SHOULD BE PLACED OVER THE DISTURBED AREA PRIOR TO SEEDING. DEEPER TOPSOIL DEPTHS (8-12 INCHES OR GREATER) ARE DESIRABLE AS THEY INCREASE THE ORGANIC MATTER AVAILABLE FOR USE BY THE PLANTS, ALLOW FOR DEEPER ROOT PENETRATION AND INCREASE THE MOISTURE HOLDING ABILITY OF THE SOIL. 4.TOPSOIL SHALL BE FREE OF ALL ROCK AND DEBRIS LARGER THAN 3/4" IN SIZE. 5.TOPSOIL IS DEFINED AS: FERTILE, FRIABLE LOAM, CAPABLE OF SUSTAINING VIGOROUS PLANT GROWTH, FROM WELL DRAINED SITE FREE FROM FLOODING, NOT IN FROZEN OR MUDDY CONDITIONS; REASONABLE FREE FROM SUBSOIL, CLAY LUMPS, ROOTS, GRASS, WEEDS, STONES LARGER THAN 3/4 INCH IN DIAMETER, AND FOREIGN MATTER; ACIDITY RANGE (PH) OF 5.5 TO 7.5; CONTAINING MINIMUM 4 PERCENT AND MAXIMUM 20 PERCENT ORGANIC MATTER. 6.CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING ALL TOPSOIL REQUIREMENTS OF NPDES GENERAL PERMIT NO. 2 ARE MET. 7.REFERENCE GEOTECHNICAL REPORT FOR ADDITIONAL SOILS INFORMATION INCLUDING BUT NOT LIMITED TO SUBGRADE INFORMATION, FOOTING DESIGN, AND ANY POSSIBLE OVER EXCAVATION DUE TO POOR SOILS. PAVEMENT SECTIONS ON THE PLANS GOVERN OVER PAVEMENT THICKNESS IN THE SOILS REPORT. GRADING NOTES 1.AREAS TO RECEIVE STRUCTURAL FILL SHALL BE BENCHED. STRUCTURAL FILL SHALL BE COMPACTED TO A DENSITY THAT IS NOT LESS THAN 95% STANDARD PROCTOR. 2.PREPARE BOTTOM OF BENCH FOR FILL BY DISKING TO A DEPTH OF 12 INCHES AND COMPACT. ANY LOCALIZED AREAS WHICH CANNOT BE SATISFACTORILY COMPACTED OR WHICH SHOW EVIDENCE OF PUMPING ACTION SHALL BE UNDERCUT AND RE-COMPACTED WITH ON-SITE FILL MATERIALS. 3.ALL AREAS WHICH ARE TO RECEIVE PAVING SHALL HAVE THE TOP 12 INCHES DISKED AND COMPACTED TO 95% STANDARD PROCTOR DENSITY. 4.MAINTAIN ALL CUT AND FILL AREAS TO ACCOMMODATE SURFACE DRAINAGE. 5.FINISH GRADE ON ALL NON-PAVED AREAS SHALL BE WITHIN 0.20 FT, AND PAVED AREAS SHALL BE WITHIN 0.10 FT OF THE PROPOSED GRADES SHOWN ON THE PLAN 6.MAXIMUM ALLOWABLE GRADE ON ALL PROPOSED SLOPES IS 3:1. 7.THE MOISTURE CONTENT SHALL NOT DEVIATE FROM THE OPTIMUM BY MORE THAN 2% IN STRUCTURAL FILL. 8.MAXIMUM 2% CROSS-SLOPE ON ALL SIDEWALKS. 9.GRADING AND EROSION CONTROL SHALL BE DONE IN ACCORDANCE WITH THE APPROVED GRADING PLAN, SWPPP, NPDES DOCUMENTS, AND IOWA DEPARTMENT OF NATURAL RESOURCES REQUIREMENTS. LANDSCAPING NOTES 1.ALL SODDING & LANDSCAPE PLANTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE URBAN STANDARD SPECIFICATIONS, UNLESS SPECIFIED OTHERWISE. 2.ALL DISTURBED AREAS, INCLUDING THE R.O.W., SHALL BE SODDED. 3.STAKE SOD ON ALL SLOPES 4:1 OR GREATER. 4.PLANT QUANTITIES ARE FOR CONTRACTORS CONVENIENCE, THE DRAWING SHALL PREVAIL IF A CONFLICT OCCURS. 5.ALL PLANT MATERIAL SHALL CONFORM TO THE LATEST EDITION OF THE AMERICAN STANDARD FOR NURSERY STOCK (ANSI Z60.1). 6.CONTRACTOR SHALL GUARANTEE ALL PLANT MATERIAL FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE. 7.CONTRACTOR SHALL PLACE SHREDDED MULCH OR BRICK CHIPS OR WASHED STONE AROUND ALL TREES, SHRUBS AND GROUND COVER BEDS TO A DEPTH OF 4 INCHES, UNLESS NOTED. 8.PROVIDE 6MIL MINIMUM PLASTIC BELOW ROCK/BRICK. 9.THE LANDSCAPING CONTRACTOR SHALL HAVE ALL UTILITIES LOCATED BEFORE STARTING ANY SITE WORK OR PLANTING. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING UTILITIES. 10.CONTRACTOR SHALL BE RESPONSIBLE MAINTAINING APPROPRIATE LEVEL OF WATERING FOR ALL NEW PLANTS FOR A PERIOD OF 30 DAYS. 11.CONTRACTOR SHALL DESIGN AND PROVIDE IRRIGATION SYSTEM. COORDINATION WITH ARCHITECT REQUIRED. 12.ALL BEDS TO RECEIVE GRANULAR PRE-EMERGENT WEED CONTROL BEFORE AND AFTER MULCH IS INSTALLED. FIRE SAFETY CONSTRUCTION NOTE: 1.APPROVED FIRE APPARATUS ACCESS ROADS SHALL BE PROVIDED AS SOON AS CONSTRUCTION COMMENCES. IF PAVING IS NOT INSTALLED PRIOR TO BUILDING CONSTRUCTION COMMENCING AFTER FOOTING INSTALLED, AN APPROVED ROUTE AROUND THE EXTERIOR OF THE BUILDING TO EXTEND WITHIN 100 FEET OF ALL PORTIONS OF THE EXTERIOR WALLS SHALL BE PROVIDED AND COMPLY WITH REQUIREMENTS OF SECTION 503.2 OF THE IFC. UTILITY NOTES 1.QUANTITY CALLOUTS ON PIPE LENGTHS ARE APPROXIMATE AND SHOULD BE USED FOR REFERENCE ONLY. 2.PIPE LENGTHS CALLED OUT ON PLANS DO NOT INCLUDE FLARED END SECTION, WHERE APPLICABLE. 3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION OF ALL UTILITIES. ANY DAMAGE TO SAID UTILITIES SHALL BE REPAIRED TO THE SATISFACTION OF THE OWNER AT THE CONTRACTORS EXPENSE. 4.THE CONTRACTOR SHALL RELOCATE EXISTING UTILITIES AS NECESSARY, SHOWN OR NOT SHOWN. 5.THE CONTRACTOR SHALL COORDINATE WITH THE CITY ON ALL SIZE, DEPTHS, AND MATERIALS OF ALL PROPOSED UTILITIES. 6.THE CONTRACTOR MUST PROVIDE AS-BUILTS OF ALL UTILITIES, INCLUDING DEPTH AND LOCATION OF ALL SERVICES IF REQUIRED BY CITY. 7.IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE APPROPRIATE UTILITY COMPANIES PRIOR TO CONNECTION OR DISCONNECTION OF A SERVICE LINE. 8.CONTRACTOR IS TO COMPLY WITH THE LATEST SUDAS SPECIFICATIONS FOR MAINTENANCE, INSTALLATION, AND TESTING FOR CONSTRUCTION. 9.THE CONTRACTOR SHALL COORDINATE THE ADJUSTMENT OF ANY AND ALL EXISTING AND PROPOSED UTILITIES TO PROPOSED GRADES. EXISTING UTILITIES SHALL BE RAISED OR LOWERED IN ACCORDANCE WITH THE UTILITY OWNER REQUIREMENTS. ANY NECESSARY ADJUSTMENTS SHALL BE CONSIDERED INCIDENTAL TO CONSTRUCTION. 10.ACTIVE EXISTING FIELD TILES ENCOUNTERED DURING CONSTRUCTION SHALL BE REPAIRED, REROUTED, OR CONNECTED TO PUBLIC OR PRIVATE STORM SEWER TO REMAIN IN SERVICE. THE TILE SHOULD BE DIRECTED TO PUBLIC STORM SEWER IF POSSIBLE. THE CONTRACTOR SHALL RECORD THE ELEVATION AND LOCATION OF ALL TILES. 11.ALL RIP RAP CALLED OUT ON PLANS SHALL BE UNDERLAIN WITH ENGINEERING FABRIC. 12.ALL STRUCTURE SIZES CALLED OUT ON PLANS ARE MINIMUM INSIDE WALL DIMENSIONS. 13.ALL PROPOSED UTILITIES SHALL BE PRIVATE, UNLESS NOTED OTHERWISE. 14.ALL STRUCTURES CALLED OUT AS "MODIFIED" OR "SPECIAL" SHALL BE ENGINEERED BY THE PRECASTER TO ENSURE STRUCTURE STABILITY. MODIFICATIONS INCLUDE ADDITIONAL WALL LENGTH TO ACCOUNT FOR LARGE PIPE DIAMETERS AND ADDITIONAL WALL WIDTH & BASE DEPTH TO ACCOUNT FOR DEEPER STRUCTURES. ANY AND ALL MODIFICATIONS TO STANDARD STRUCTURES SHALL BE CONSIDERED INCIDENTAL TO BID ELECTRICAL SERVICE NOTES 15.ALL SITE LIGHTING SHALL NOT SPILL ONTO ADJACENT PROPERTIES OR RIGHT-OF-WAYS 16.TRANSFORMER PAD IS SHOWN FOR REFERENCE ONLY AND MAY NOT BE DRAWN TO ACTUAL SIZE. PAD SHALL CONFORM TO ALL UTILITY COMPANY DESIGN STANDARDS AND SPECIFICATIONS. SANITARY SERVICE NOTES 17.SANITARY SEWER SERVICE CONNECTIONS SHALL BE PLACED AT A SLOPE OF NO LESS THAN 2% FOR A 4" PIPE AND 1% FOR A 6" PIPE. SERVICES SHALL MAINTAIN 18" OF VERTICAL SEPARATION FROM THE WATER MAIN WITH 18" OF COMPACTED LOW PERMEABILITY SOIL BETWEEN THE UTILITIES WITHIN 10' OF THE CROSSING. STORM WATER SERVICE NOTES 18.ALL STORM SEWER IN THE ROW SHALL BE RCP (CLASS III RCP), UNLESS OTHERWISE SPECIFIED. 19.ALL PROPOSED RCP STORM SEWER PIPE JOINTS SHALL BE FABRIC WRAPPED AND THE LAST 3 PIPE SECTIONS ON THE APRON SHALL BE TIED WITH RF-14 TYPE II CONNECTORS. ALL APRONS SHALL HAVE A STANDARD FOOTING AND TRASH GUARD. 20.ALL SUMP SERVICE LINES SHALL HAVE TRACE WIRE WATER SERVICE NOTES 21.WATER SERVICE SHALL BE TYPE K COPPER, DIP OR HDPE, DEPENDING ON SIZE AND JURISDICTIONAL REQUIREMENTS. IF CONTAMINATED OR "HOT" SOILS, ENSURE APPROPRIATE PIPE IS BEING UTILIZED. SIZE OF WATER MAIN AS SHOWN ON PLANS. 22.TRACER WIRE SHALL BE ADDED TO ALL WATER MAIN, AND BROUGHT TO THE SURFACE AT EVERY HYDRANT. 23.THRUST BLOCKS SHALL BE INSTALLED AS REQUIRED AND SHALL BE CONSIDERED INCIDENTAL TO WATER MAIN CONSTRUCTION. 24.ANY AND ALL HYDRANT AND VALVE EXTENSIONS, TOGETHER WITH VERTICAL BENDS, SHALL BE CONSIDERED INCIDENTAL TO WATER MAIN CONSTRUCTION. NO ADDITIONAL PAYMENT WILL BE PROVIDED FOR INCIDENTAL ITEMS. 25.ALL WATER LINES SHALL HAVE A MINIMUM OF 5.5 FEET OF COVER UNLESS NOTED OTHERWISE. EXISTING UTILITIES NOTE 1.THE LOCATIONS OF THE EXISTING UTILITIES SHOWN HEREON ARE APPROXIMATE. THEY HAVE BEEN PLOTTED FROM AVAILABLE SURVEYS AND/OR RECORDS. THE CONTRACTOR IS RESPONSIBLE TO ENSURE THAT ANY EXISTING UTILITIES (SHOWN OR NOT SHOWN) ARE NOT DAMAGED DURING CONSTRUCTION: IOWA ONE-CALL (1-800-292-8989). UTILITY CONFLICT NOTES 1.UTILITY CONFLICTS MAY EXIST ACROSS THE SITE WITH NEW UTILITIES, GRADING, PAVING ETC. MOST UTILITY CONFLICTS HAVE BEEN CALLED OUT FOR CONTRACTOR CONVENIENCE. 2.CONTRACTOR IS RESPONSIBLE FOR ALL UTILITY CONFLICTS BETWEEN AN EXISTING UTILITY AND PROPOSED CONSTRUCTION THAT ARE EITHER CALLED OUT ON THE PLANS OR NOT CALLED OUT. 3.CONTRACTOR SHALL COMPLY WITH ALL DNR REQUIREMENTS FOR PIPE MATERIAL, PIPE JOINTS, AND ANY OTHER APPLICABLE REQUIREMENTS ANY TIME A STORM SEWER OR SANITARY SEWER CROSSES OVER OR LESS THAN 18" BELOW A WATER MAIN. 4.FOR ALL CRITICAL CROSSINGS WITH EXISTING UTILITIES, THE ELEVATION OF THE EXISTING UTILITY SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. NOTIFY PELDS DESIGN SERVICES PRIOR TO CONSTRUCTION IF A CONFLICT EXISTS. SPECIFICATIONS NOTES 1.ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST VERSION OF THE URBAN STANDARDS SPECIFICATIONS FOR PUBLIC IMPROVEMENTS ON THE DATE OF APPROVAL AND THE LOCAL JURISDICTION SUPPLEMENTAL SPECIFICATIONS. 2.IN THE EVENT OF A DISCREPANCY BETWEEN THE PROJECT SPECIFICATIONS AND THE LOCAL JURISDICTION REQUIREMENTS AND SPECIFICATIONS, PLUMBING CODE, AND URBAN STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENT, THE LOCAL JURISDICTION STANDARD SPECIFICATIONS SHALL GOVERN. 3.FOR ALL SPECIFICATION DISCREPANCIES, THE PROJECT ENGINEER SHALL BE CONTACTED PRIOR TO PROCEEDING WITH CONSTRUCTION. IF THE ENGINEER IS NOT CONTACTED, CONTRACTOR SHALL BE RESPONSIBLE FOR ANY PROBLEMS THAT RESULT FROM SAID DISCREPANCIES. REQUIRED AS-BUILT NOTES 1.THE CONTRACTOR SHALL BE RESPONSIBLE FOR COST OF AS-BUILT TOPO, IF REQUIRED BY CITY. 2.CONTRACTOR SHALL CONTACT PELDS DESIGN SERVICES TO PERFORM SAID AS-BUILT SURVEYS. 3.IF ANYTHING HAS BEEN CONSTRUCTED INCORRECTLY, CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SUBSEQUENT AS-BUILT SURVEYS UNTIL ISSUES HAVE BEEN RECTIFIED. GENERAL NOTES 1.THE LOCAL JURISDICTION MUST BE NOTIFIED BY ALL CONTRACTORS 48 HOURS PRIOR TO COMMENCING WORK. THE LOCAL JURISDICTION IS THE CITY OF WAUKEE. 2.ALL PROPOSED MATERIALS AND STRUCTURES SHALL BE APPROVED BY THE LOCAL JURISDICTION AND BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS 3.ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST SUDAS STANDARDS. ALL PROVIDED SUDAS DETAILS ARE FOR REFERENCE ONLY AND THE LATEST VERSIONS SHALL BE IMPLEMENTED. 4.ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE CURRENT O.S.H.A. CODES AND STANDARDS. NOTHING INDICATED ON THESE PLANS SHALL RELIEVE THE CONTRACTOR FROM COMPLYING WITH THE APPROPRIATE SAFETY REGULATIONS. 5.ALL NECESSARY CONSTRUCTION SIGNS, BARRICADES AND OTHER TRAFFIC CONTROL DEVICES REQUIRED DURING CONSTRUCTION WILL BE FURNISHED BY THE CONTRACTOR. SIGNS, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES MUST BE IN CONFORMANCE WITH THE "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS." 6.PELDS DESIGN SERVICES SHALL NOT BE LIABLE FOR ANY INJURIES THAT HAPPEN ON SITE. THIS SHALL INCLUDE BUT NOT BE LIMITED TO TRENCH COLLAPSES FROM VARYING SOIL CONDITIONS OR INJURIES CAUSED BY UNDERGROUND UTILITIES INCLUDING UTILITIES THAT ARE NOT SHOWN ON PLAN. 7.THE CONTRACTOR IS LIABLE FOR ALL DAMAGES TO PUBLIC OR PRIVATE PROPERTY CAUSED BY THEIR ACTION OR INACTION IN PROVIDING FOR STORM WATER FLOW DURING CONSTRUCTION. DO NOT RESTRICT FLOWS IN EXISTING DRAINAGE CHANNELS, STORM SEWER, OR FACILITIES. 8.IF A PRE-CONSTRUCTION MEETING IS REQUIRED PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE THIS MEETING. 9.LABORATORY TESTS SHALL BE PERFORMED BY THE OWNER UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL PROVIDE SAMPLES OF MATERIAL REQUIRED FOR LABORATORY TESTS AND TESTING IN ACCORDANCE WITH THE URBAN STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS. 10.THE CONTRACTOR SHALL PROTECT ALL STRUCTURES NOT SHOWN AS REMOVALS ON THE PLANS. 11.THE CONTRACTOR SHALL OBTAIN ANY AND ALL NECESSARY PERMITS PRIOR TO ANY CONSTRUCTION. CONTRACTOR SHALL WORK WITH OWNER OR OWNER'S REPRESENTATIVE ON ALL REQUIRED STORM WATER DISCHARGE PERMITS FROM THE IOWA DEPARTMENT OF NATURAL RESOURCES AND THE LOCAL JURISDICTION. 12.THE CONTRACTOR SHALL PICK UP ANY DEBRIS SPILLED ONTO THE ADJACENT RIGHT OF WAY OR ABUTTING PROPERTIES AS THE RESULT OF CONSTRUCTION, AT THE END OF EACH WORK DAY AND PRIOR TO A RAIN EVENT. 13.THE CONTRACTOR IS RESPONSIBLE FOR THE PROMPT REMOVAL OF ALL MUD THAT HAS BEEN TRACKED OR WASHED UNTO ADJACENT PROPERTY OR RIGHT OF WAY UNTIL SUCH TIME THAT PERMANENT VEGETATION HAS BEEN ESTABLISHED. 14.DISPOSE OF ALL EXCESS MATERIALS AND TRASH IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL REQUIREMENTS. PROVIDE WASTE AREAS OR DISPOSAL SITES OR EXCESS MATERIALS NOT DESIRABLE FOR INCORPORATION INTO THE PROJECT. 15.ALL CONSTRUCTION WITHIN THE PUBLIC R.O.W/EASEMENTS, AND/OR ANY CONNECTION TO PUBLIC SEWERS AND STREETS SHALL COMPLY WITH THE LOCAL JURISDICTION. 16.THE CONTRACTOR SHALL CONTACT THE LOCAL JURISDICTION TO SCHEDULE ANY REQUIRED INSPECTIONS AT LEAST ONE WEEK PRIOR TO ANY CONSTRUCTION WITHIN PUBLIC R.O.W/EASEMENTS, AND/OR ANY CONNECTION TO PUBLIC SEWERS AND STREETS 17.IN THE EVENT OF ANY CONFLICTING NOTES BETWEEN THE COVER SHEET AND ALL OTHER SHEETS, THE NOTES ON THE COVER SHEET SHALL SUPERCEDE ALL OTHERS 18.IN THE EVENT OF ANY CONFLICTING INFORMATION BETWEEN THE LABEL, ELECTRONIC CAD FILE, AND THE ELECTRONIC SURFACE, THE DESIGN ENGINEER SHALL BE CONTACTED FOR CLARIFICATION 19.ALL WORK SHALL BE DONE IN ACCORDANCE WITH 2024 WAUKEE STANDARD SPECIFICATIONS. SURVEY NOTES 1.SURVEY WORK WAS COMPLETED BY PELDS DESIGN SERVICES IN FEBRUARY 2025. SEE SITE SURVEY PROVIDED AS PART OF THIS SET OF PLANS FOR EXISTING SITE CONDITIONS AND BOUNDARY INFORMATION. STAKING NOTES 1.IT IS RECOMMENDED FOR THE CONTRACTOR TO HAVE ALL STAKING DONE UNDER THE SUPERVISION OF A LICENSED LAND SURVEYOR AND IN COORDINATION WITH THE PROJECT ENGINEER. 2.IT IS RECOMMENDED FOR THE CONTRACTOR TO HAVE ALL STAKING DONE DIRECTLY UNDER THE GENERAL CONTRACTOR BY A SINGLE COMPANY. 3.STAKING DOES NOT RELIEVE CONTRACTOR OF ULTIMATE RESPONSIBILITY TO CONSTRUCT THE PROJECT PER PLAN. DEMO NOTES 1.SAWCUT & REMOVE ALL PAVEMENT TO FULL DEPTH OF SLAB. 2.PROTECT ALL TREES NOT CALLED OUT FOR REMOVAL WITH ORANGE CONSTRUCTION FENCE AT THE DRIP LINE. 3.PAVEMENT STRIPING CALLED OUT FOR REMOVAL SHALL BE SANDBLASTED. NO GRINDING WILL BE ALLOWED. 4.PROPERLY DISCONNECT ALL PUBLIC AND PRIVATE UTILITIES, AS NECESSARY. 5.COMPLY WITH LOCAL, STATE, AND FEDERAL REGULATIONS TO REMOVE AND PROPERLY DISPOSE OF SIDEWALKS, STEPS, DRIVEWAYS, AND STRUCTURES (INCLUDING BOTH ABOVE GROUND AND BELOW GROUND ELEMENTS). 6.COMPLY WITH LOCAL, STATE, AND FEDERAL REGULATIONS TO REMOVE FUEL TANKS, SEPTIC TANKS, CISTERNS, AND ANY OTHER UNDERGROUND FACILITIES; AND TO PROPERLY DISPOSE OF ANY LIQUIDS OR PRODUCTS CONTAINED WITHIN THESE ITEMS. 7.PLACE BACKFILL MATERIAL IN HOLES AND DEPRESSIONS, GRADE THE SITE, AND ESTABLISH GROUND COVER. 8.PROTECT EXISTING FIRE HYDRANTS, STREET LIGHTS, TRAFFIC SIGNALS, UTILITY POLES, FIRE ALARM BOXES, WIRE CABLES, UNDERGROUND UTILITIES, AND OTHER APPURTENANCES IN THE VICINITY OF THE DEMOLITION SITE 9.COMPLY WITH NOISE POLLUTION REQUIREMENTS AND ANY WORKING HOUR RESTRICTIONS OF THE JURISDICTION. 10.MAINTAIN OR RE-ESTABLISH ALL TILES, ROADWAY SUBDRAINS, CULVERTS, OR OTHER DRAINAGE FACILITIES NOT IDENTIFIED IN THE CONTRACT DOCUMENTS FOR REMOVAL. 11.IMPLEMENT THE APPROVED EROSION AND SEDIMENT CONTROL PLAN FOR EACH SITE PRIOR TO INITIATING DEMOLITION BY PLACING ALL REQUIRED DEVICES; INCLUDE MEASURES TO PREVENT TRACKING OF MUD ONTO ADJACENT STREETS OR ALLEYS. 12.COMPLY WITH ALL APPLICABLE AIR POLLUTION REQUIREMENTS OF THE JURISDICTION. USE WATER OR APPROPRIATE CHEMICALS FOR CONTROL OF DUST IN THE DEMOLITION AREA, ON HAULING EQUIPMENT, ON ADJACENT ROADWAYS, AND WHEN GRADING THE SITE. 13.TAKE STEPS TO PREVENT THE GENERATION OF LITTER DURING DEMOLITION AND COLLECT ALL LITTER FROM THE DEMOLITION AREA AT THE END OF EACH WORKING DAY. LOAD TRUCKS TO PREVENT LEAKAGE OR BLOWING OF DEBRIS. 14.REMOVE ALL CONCRETE, ASPHALT, OR MASONRY SLABS AND APPURTENANCES. 15.REMOVE AND DISPOSE OF ALL BRUSH, SHRUBS, TREES, LOGS, DOWNED TIMBER, AND OTHER YARD WASTE ON THE SITE UNLESS OTHERWISE SPECIFIED IN THE CONTRACT DOCUMENTS. DO NOT MIX WITH DEMOLITION MATERIAL. REMOVE STUMPS TO A MINIMUM OF 2 FEET BELOW FINISH GRADE. PROTECT ANY TREES OR OTHER VEGETATION NOT DESIGNATED FOR REMOVAL BY PLACING A FENCE AT THE DRIP LINE ENCOMPASSING THE ENTIRE TREE AND KEEPING ALL OPERATIONS OUTSIDE OF THE FENCED IN AREA, INCLUDING STORAGE OF EQUIPMENT OR MATERIALS. AT NO ADDITIONAL COST TO THE CONTRACTING AUTHORITY, REPLACE ANY TREES THAT ARE DESIGNATED FOR PROTECTION BUT ARE DAMAGED BEYOND TREATMENT. THE ENGINEER WILL DETERMINE SIZE AND SPECIES OF THE REPLACEMENT TREE. 16.SAW-CUT ALL HARD SURFACING AT LOCATION OF REMOVAL LIMITS. 17.WHERE SELECTIVE DEMOLITION IS SHOWN AT PAVED AREAS, DEMOLISH THE EXISTING PAVING BACK TO AN EXISTING CONTROL JOINT NEAR THE LOCATION SHOWN. WETLAND NOTES 1.PELDS DESIGN SERVICES DOES NOT PERFORM WETLAND STUDIES OR WETLAND MITIGATION. IT IS THE OWNER'S RESPONSIBILITY TO DETERMINE IF ANY WETLANDS ARE LOCATED ON THE PROJECT SITE AND PERFORM ANY NECESSARY MITIGATION PRIOR TO THE COMMENCEMENT OF CONSTRUCTION ACTIVITIES. DISCLAIMER 1.THIS DRAWING IS BEING MADE AVAILABLE BY PELDS DESIGN SERVICES (P.D.S.) FOR USE ON THIS PROJECT IN ACCORDANCE WITH P.D.S.'S AGREEMENT FOR PROFESSIONAL SERVICES. P.D.S. ASSUMES NO RESPONSIBILITY OR LIABILITY (CONSEQUENTIAL OR OTHERWISE) FOR ANY USE OF THESE DRAWINGS (OR ANY PART THEREOF) EXCEPT IN ACCORDANCE WITH THE TERMS OF SAID AGREEMENT. 2.P.D.S DISCLAIMS ANY AND ALL LIABILITY OR RESPONSIBILITY FOR INFORMATION THAT DOES NOT BEAR THE ORIGINAL SEAL AND SIGNATURE OF THE PROFESSIONAL IN CHARGE. BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: C-002 - NOTE SHEET 08.07.2025 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: L. BURKE J:\2025 Projects\25-010 I80 WIP Plat 1 Lot 6\Engineering\Sheet Set WAUKEE, IOWA LOT 1, INTERSTATE CROSSING 555 INTERSTATE PARKWAY TITLE: ----25-010 PRELIMINARY CIVIL ENGINEERING NOTES E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E W FIELD S P I G O T SPEED L I M I T 2 5 M P H & NO P A R K I N G S I G N T GAS MARKER POST F O V FOV FOV FO V TEL TEL E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W FND. 1/2" REBAR WITH RIBBON 0.94' SOUTH OF CORNER (NEW CORNER NOT SET) FN D . 1 / 2 " R E B A R W I T H R I B B O N & SM A S H E D C A P 0 . 3 7 ' S W O F C O R N E R (NE W C O R N E R N O T S E T ) FND. 1/2" REBAR WITH RIBBON & BROKEN CAP FND. 1/2" REBAR WYC #15980 FN D . 1 / 2 " R E B A R WY C # 1 5 9 8 0 FND. 1/2" REBAR WYC #15980 FND. 1 / 2 " R E B A R WYC # 1 5 9 8 0 FND. 1/2" REBAR STOP SIGN LA N D F O R S A L E S I G N ADA WARNING STRIP ADA WARNING STRIP IRR IRR WM R O C K CHECK DAM ROCK CHECK D A M R O C K CHECK DAM E W E W 6" WATER SERVICE E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E GAS E GAS E GAS E GAS E G A S E GAS E GAS E GAS E GAS E GAS E GAS E GAS E GA S E G A S E G A S E G A S E GA S E GAS E GAS E GAS E S T E S T E S T E S T E S T E S T North 568 6 5 9 . 1 4 ' E a s t 1 5 3 5 9 1 2 . 6 2 ' E l e v 1 0 0 5 . 4 5 ' " G P S # 1 1 C U T - X " North 568373.25' East 1535903.19' Elev 997.05' "CP 100 CUT-X" North 568452.84' East 1536170.01' Elev 1003.41' "GPS#13 North 568723.51' East 1536191.29' Elev 1004.67' "GPS#12 CUT-X" LOT - 6 I-80 INDUSTRIAL PARK PLAT 1 CONCRE T E S U R F A C E CONCRE T E S U R F A C E F.L. = 1001.21 12 " P V C O U T L E T P I P E FL = 1 0 0 1 . 0 2 15 " C M P AR E A I N T A K E SAN MH RIM = 1002.98 F.L. (N) = 992.31 F.L. (W) = 992.24 E ST E ST E ST E ST DETENTION BASI N E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W ASPHALT S U R F A C E E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E S A N E S A N E S A N E S A N E S A N FL = 9 9 7 . 3 2 SAN MH RIM = 1001.64 F.L. (E) = 991.14 F.L. (W) = 991.10 SAN MH RIM = 994.43 F.L. (E) = 983.22 F.L. (W) = 983.19 ST O R M M H RI M = 9 9 0 . 8 4 F.L . = 9 8 4 . 2 4 AREA IN T A K E MH RIM = 9 9 3 . 6 8 F.L. = 9 8 8 . 3 7 AREA IN T A K E GRATE = 9 9 3 . 1 0 F.L. = 98 8 . 6 1 INTE R S T A T E P A R K W A Y R2 2 / U T E A V E C1 C2 C3 N1 ° 4 3 ' 2 0 " E 1 0 8 . 8 1 ' N79° 59' 38 " E 4 0 . 8 0 ' N1 ° 4 1 ' 0 4 " E 7 3 . 3 5 ' S74° 24 ' 2 5 " W 4 2 2 . 0 8 ' S2 ° 2 0 ' 1 8 " E 3 0 . 4 9 ' S35 ° 5 0 ' 1 3 " W 1 6 3 . 6 4 ' 986987 98 8 98 9 990 991 99 1 99 2 99 2 99 3 9 9 3 9 9 4 99 4 9959959 9 5 9 9 5 996 9969 9 6 99 6 997 99 7 99 8 9 9 8 99 9 9 9 9 10 0 0 1 0 0 0 10 0 1 1 0 0 1 1 0 0 2 1 0 0 2 10 0 2 1 0 0 2 100 3 1 0 0 3 1 0 0 3 1 0 0 3 1 0 0 4 10 0 4 10 0 4 1 0 0 4 1 0 0 5 100 5 1 0 0 5 10 0 6 1 0 0 6 1 0 0 7 10 0 7 1 0 0 1 10 0 2 10 0 2 10 0 2 1003 10 0 3 10 0 3 10 0 4 1004 10 0 4 1005 1005 10 0 5 990 99 1 99 2 993 994 99 5 99 6 9 9 7 9 9 8 9 9 9 1 0 0 0 1001 1 0 0 2 1 0 0 3 1 0 0 3 10 0 4 10 0 4 988 989 98 9 989 990 99 0 990 99 1 991991 99 2 99 3 99 4 99 5 99 6 99 7 99 8 99 9 10 0 0 10 0 1 10 0 2 100 3 10 0 4 10 0 4 1 0 0 4 10 0 5 10 0 5 100 5 10 0 5 15" R C P 12" WAT E R S E R V I C E 12" WAT E R S E R V I C E 12 " W A T E R S E R V I C E E S A N E S A N E S A N F.L. = 1000.88 PARCE L 2 0 - 7 9 B K 2 0 2 0 P G 3 5 9 9 3 ROADWAY EASEMENT BK 456 PG 93 10' P U E BK 2 0 1 7 P G 2 3 1 9 3 15' SSE BK 2017 PG 23193 10' WATERMAIN EASEMENT BK 2017 PG 23193 8.00' 10' PUE BK 2017 P G 2 3 1 9 3 30' SET B A C K L I N E 30 ' S E T B A C K L I N E 30' PL A T T E D S E T B A C K L I N E 30' P L A T T E D S E T B A C K L I N E 20' STORM SEWER & OVERLAND FLOWAGE EASEMENT BK 2017 PG 23193 12" VERTICAL PVC INV. = 985.33 GROUND EL. = 985.93 EXIST 6" SAN. STUB EST. FL: 983.72 EXISTING MH1 STANDARD SW-301 RIM:1003.19 FL OUT:993.63 8" S EXISTING SIDEWALK EXISTING ROAD Curve Table Curve # C1 C2 C3 Length 278.19 167.17 50.93 Radius 265.00 368.00 35.00 Delta 60°08'53" 26°01'41" 83°22'28" Chord Direction N89° 19' 03"E N72° 15' 24"E N43° 32' 57"E Chord Length 265.59' 165.74' 46.55' Tangent 153.45' 85.05' 31.17' PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: C-003 - TOPO SHEET 08.07.2025 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: L. BURKE J:\2025 Projects\25-010 I80 WIP Plat 1 Lot 6\Engineering\Sheet Set WAUKEE, IOWA LOT 1, INTERSTATE CROSSING 555 INTERSTATE PARKWAY TITLE: ----25-0101"=20' PRELIMINARY LEGEND: MORE OR LESS GUTTER ELEVATION TOP OF CURB ELEVATION +/- EXISTING/ PROPOSED ELEVATION 123.45G 123.45TC FLOWLINE ELEVATIONFL FINISHED FLOORF.F. 123.45123.45/ CALCULATED CORNER FOUND CORNER CONTROL POINT ELEC. TRANSFORMER ELEC. METER ELEC. BOX SIGN PARKING SPACE STREET LIGHT POWER POLE LIGHT POLE CALCULATED SECTION CORNER FOUND SECTION CORNER AREA LIGHT GUY ANCHOR ELEC. MANHOLE ELEC. VAULT GAS VALVE GAS METER UTILITY PEDESTAL CABLE TV JUNCTION BOX SANITARY SEWER MANHOLE STORM SEWER MANHOLE CLEANOUT DOWNSPOUTD SINGLE INTAKE WATER VALVE WATER TEE FLARED END SECTION FIRE HYDRANT VALVE PROPOSED UTILITY LINEP XX EXISTING UTILITY LINEE XX WATER METER THROAT INTAKE FENCE LINE FIBER OPTIC WATER GAS LINE SANITARY SEWER STORM SEWER UNDERGROUND TEL. OVERHEAD TEL. W ST UGT OHT G SAN UNDERGROUND ELEC.UGE OVERHEAD ELEC.OHE FO CABLE TELEVISIONCATV AREA INTAKE EAST LINE OF PROPOSED LOT 1 E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E W FIELD S P I G O T SPEED L I M I T 2 5 M P H & NO P A R K I N G S I G N T GAS MARKER POST F O V FOV FOV FO V TEL TEL E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W STOP SIGN LA N D F O R S A L E S I G N IRR IRR WM R O C K CHECK DAM ROCK CHECK D A M R O C K CHECK DAM E W E W 6" WATER SERVICE E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E GAS E GAS E GAS E GAS E G A S E GAS E GAS E GAS E GAS E GAS E GAS E GAS E GA S E G A S E G A S E G A S E GA S E GAS E GAS E GAS E S T E S T E S T E S T E S T E S T CONCRE T E S U R F A C E CONCRE T E S U R F A C E F.L. = 1001.21 12 " P V C O U T L E T P I P E FL = 1 0 0 1 . 0 2 15 " C M P AR E A I N T A K E E ST E ST E ST E ST DETENTION BASI N E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W ASPHALT S U R F A C E E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E S A N E S A N E S A N E S A N E S A N FL = 9 9 7 . 3 2 ST O R M M H RI M = 9 9 0 . 8 4 F.L . = 9 8 4 . 2 4 AREA IN T A K E MH RIM = 9 9 3 . 6 8 F.L. = 9 8 8 . 3 7 AREA IN T A K E GRATE = 9 9 3 . 1 0 F.L. = 98 8 . 6 1 INTE R S T A T E P A R K W A Y R2 2 / U T E A V E 15" R C P 12" WAT E R S E R V I C E 12" WAT E R S E R V I C E 12 " W A T E R S E R V I C E F.L. = 1000.88 S74° 24 ' 2 5 " W 360.00' S 2 ° 2 0 ' 1 8 " E 30 . 4 9 ' S35 ° 5 0 ' 1 3 " W 16 3 . 6 4 ' C9 C7 71.03 12" VERTICAL PVC INV. = 985.33 GROUND EL. = 985.93 N1 ° 3 9 ' 3 7 " E 20 3 . 0 9 ' C8 E S A N E S A N E S A N EXISTING ROAD P.C.C DEMO Curve Table Curve # C9 C7 C8 Length 278.19 167.17 12.49 Radius 265.00 368.00 35.00 Delta 60°08'53" 26°01'41" 20°26'37" Chord Direction N89° 19' 03"E N72° 15' 24"E N75° 00' 52"E Chord Length 265.59' 165.74' 12.42' Tangent 153.45' 85.05' 6.31' PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: C-100 - DEMO SHEET 08.07.2025 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: L. BURKE J:\2025 Projects\25-010 I80 WIP Plat 1 Lot 6\Engineering\Sheet Set WAUKEE, IOWA LOT 1, INTERSTATE CROSSING 555 INTERSTATE PARKWAY TITLE: ----25-0101"=20' PRELIMINARY LEGEND: MORE OR LESS GUTTER ELEVATION TOP OF CURB ELEVATION +/- EXISTING/ PROPOSED ELEVATION 123.45G 123.45TC FLOWLINE ELEVATIONFL FINISHED FLOORF.F. 123.45123.45/ CALCULATED CORNER FOUND CORNER CONTROL POINT ELEC. TRANSFORMER ELEC. METER ELEC. BOX SIGN PARKING SPACE STREET LIGHT POWER POLE LIGHT POLE CALCULATED SECTION CORNER FOUND SECTION CORNER AREA LIGHT GUY ANCHOR ELEC. MANHOLE ELEC. VAULT GAS VALVE GAS METER UTILITY PEDESTAL CABLE TV JUNCTION BOX SANITARY SEWER MANHOLE STORM SEWER MANHOLE CLEANOUT DOWNSPOUTD SINGLE INTAKE WATER VALVE WATER TEE FLARED END SECTION FIRE HYDRANT VALVE PROPOSED UTILITY LINEP XX EXISTING UTILITY LINEE XX WATER METER THROAT INTAKE FENCE LINE FIBER OPTIC WATER GAS LINE SANITARY SEWER STORM SEWER UNDERGROUND TEL. OVERHEAD TEL. W ST UGT OHT G SAN UNDERGROUND ELEC.UGE OVERHEAD ELEC.OHE FO CABLE TELEVISIONCATV AREA INTAKE GRIND EXISTING CURB AND INSTALL SUDAS TYPE "A" DRIVEWAY PROTECT UTILITIES AND MANHOLE PROTECT LANDSCAPING PROTECT LANDSCAPING PROTECT UTILITY REMOVE ROCK CHECK DAMS REMOVE SIGN PROTECT EXISTING SIDEWALK RAMP PROTECT UTILITY REMOVE HYDRANT PROTECT UTILITIES REMOVE/REPLACE STAND PIPE PROTECT HYDRANT EXISTING SANITARY STUB TO BE CAPPED AT MAIN AND ABANDONDED RELOCATE HYDRANT ASSEMBLY & VALVE IF POSSIBLE. IF CONDITIONS DO NOT ALLOW FOR REUSE, THEN A NEW HYDRANT ASSEMBLY & VALVE ARE TO BE INSTALLED PROTECT UTILITIES PRO P O S E D 5 ' S I D E W A L K E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E W SPEED L I M I T 2 5 M P H & NO P A R K I N G S I G N T F O V FOV FOV FO V TEL TEL E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W STOP SIGN IRR IRR WM E W E W E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E GAS E GAS E GAS E GAS E G A S E GAS E GAS E GAS E GAS E GAS E GAS E GAS E GA S E G A S E G A S E G A S E GA S E GAS E GAS E GAS E S T E S T E S T E S T E S T E S T CONCRE T E S U R F A C E CONCRE T E S U R F A C E E ST E ST E ST E ST E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W ASPHALT S U R F A C E E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E S A N E S A N E S A N E S A N E S A N INTE R S T A T E P A R K W A Y R2 2 / U T E A V E PROPO S E D 5 ' S I D E W A L K ROADWAY EASEMENT BK 456 PG 93 10' P U E BK 2 0 1 7 P G 2 3 1 9 3 15' SSE BK 2017 PG 23193 10' WATERMAIN EASEMENT BK 2017 PG 23193 8.00' 10' PUE BK 2017 P G 2 3 1 9 3 30' SET B A C K L I N E 30 ' S E T B A C K L I N E 30' PL A T T E D S E T B A C K L I N E PROPOSED BLOCK RETAINING WALL REFER TO PLANS PREPARED BY TOMETICH ENGINEERING 30' P L A T T E D S E T B A C K L I N E PROPOSED 35'x10' TEMP. GRADING EASEMENT 20' STORM SEWER & OVERLAND FLOWAGE EASEMENT BK 2017 PG 23193 PROP O S E D BUILD I N G 16,200 S F F.F. EL E V . 1 0 0 1 . 5 0 H.C. S I G N A G E PROP O S E D O V E R H E A D D O O R S PROPO S E D O V E R H E A D D O O R S PROP O S E D O V E R H E A D D O O R S H.C. S I G N A G E P R O P O S E D 5 ' S I D E W A L K 6 SPA C E S @ 9 ' x 1 7 ' 9 SPA C E S @ 9 ' x 1 7 ' 9 SPA C E S @ 9 ' x 1 7 ' 9 SPA C E S @ 9 ' x 1 7 ' INCLU D I N G 1 A D A S P A C E 8 SPA C E S @ 9 ' x 1 7 ' INCLU D I N G 1 A D A S P A C E 7 SPA C E S @ 9 ' x 1 7 ' PROPOSED RETAINING WALL WITH GUARDRAIL REFER TO PLANS PREPARED BY TOMETICH ENGINEERING PROPOSED TRASH ENCLOSURE REFER TO ARCH PLANS PR O P O S E D 1 0 ' P U E 10.00 PROPOSED BIOSWALE PROPOSED BIOSWALE PROPOSED DETENTION EASEMENT PROPOSED MONUMENT SIGN HANDRAILS REQ. EXISTING ROAD 6" P.C.C. SIDEWALK LANDING SIDEWALK RAMP PROPOSED SIDEWALK 7" P.C.C. PROPOSED BUILDING SOD & IRRIGATION LIMITS 3. 5 ' M I N . V E R I F Y F R O S T D E P T H 1. 0 0 ' LC 3.00' (4) 3/4"-10 Ø X 30" ANCHOR BOLTS W/ HEAVY HEX NUT LOCKED AT END. AREA LIGHT TO BE DOUBLE NUTTED, LEVELED & SECURED W/BASE. DO NOT GROUT. CONTRACTOR TO CONFIRM BOLT PATTERN WITH LIGHT BASE, DIFFERENT PATTERN FOR SINGLE OR DOUBLE HEADS 18 . 0 0 ' LIGHT FIXTURE (RSX1 LED), SEE LIGHTING PLAN DONE BY CLSA 24" DIA. CONCRETE BASE (8) #5 VERTICAL BARS, EVENLY SPACED #3 TIES AT 10" OC (3) #3 TIES AT 3" OC 3/4" Ø RIGID CONDUIT ELECTRICAL OPENING SQUARE STRAIGHT STEEL POLE (SSS QS), SEE LIGHTING PLAN DONE BY CLSA 2. 0 0 ' PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: C-101 - LAYOUT SHEET 08.07.2025 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: L. BURKE J:\2025 Projects\25-010 I80 WIP Plat 1 Lot 6\Engineering\Sheet Set WAUKEE, IOWA LOT 1, INTERSTATE CROSSING 555 INTERSTATE PARKWAY TITLE: ----25-0101"=20' PRELIMINARY LEGEND: MORE OR LESS GUTTER ELEVATION TOP OF CURB ELEVATION +/- EXISTING/ PROPOSED ELEVATION 123.45G 123.45TC FLOWLINE ELEVATIONFL FINISHED FLOORF.F. 123.45123.45/ CALCULATED CORNER FOUND CORNER CONTROL POINT ELEC. TRANSFORMER ELEC. METER ELEC. BOX SIGN PARKING SPACE STREET LIGHT POWER POLE LIGHT POLE CALCULATED SECTION CORNER FOUND SECTION CORNER AREA LIGHT GUY ANCHOR ELEC. MANHOLE ELEC. VAULT GAS VALVE GAS METER UTILITY PEDESTAL CABLE TV JUNCTION BOX SANITARY SEWER MANHOLE STORM SEWER MANHOLE CLEANOUT DOWNSPOUTD SINGLE INTAKE WATER VALVE WATER TEE FLARED END SECTION FIRE HYDRANT VALVE PROPOSED UTILITY LINEP XX EXISTING UTILITY LINEE XX WATER METER THROAT INTAKE FENCE LINE FIBER OPTIC WATER GAS LINE SANITARY SEWER STORM SEWER UNDERGROUND TEL. OVERHEAD TEL. W ST UGT OHT G SAN UNDERGROUND ELEC.UGE OVERHEAD ELEC.OHE FO CABLE TELEVISIONCATV AREA INTAKE NOTE: -IF RETAINING WALLS ARE TALLER THAN 4' IN HEIGHT, THEY WILL REQUIRE STRUCTURAL ENGINEERED PLANS. -REFER TO EXTERIOR LIGHTING PLAN DONE BY CLSA. CONTACT JASON ODEFEY (515) 650-8119 WITH QUESTIONS. -THE DESIGN/BID ELECTRICAL CONTRACTOR TO PROVIDE A LIGHTING CIRCUIT TO THE POLE LOCATIONS. -BIO SWALE AREA CALCULATIONS: WQV REQUIRED: 4872 CF WQV PROPOSED: 4872 CF 1) AREA LIGHTING 2 - 06-20-2025 - ADDED SITE LIGHTING & DETAIL REVISIONS: 2 KEYED CONSTRUCTION NOTES: PROPOSED P.C.C. CURB 2. DROP FACE CURB - CLASS A SIDEWALK SLOPE SIDEWALK AWAY 2% MAX. PARKING LOT PAVING REF CIVIL OVER EXCAVATE 1 TO 2 FEET HORIZONTALLY BELOW FROST DEPTH IN YOUR AREA. 6x6/W1.4xW1.4 WIRE MESH 1" RADIUS FND. 1/2" REBAR WITH RIBBON 0.94' SOUTH OF CORNER (NEW CORNER NOT SET) FN D . 1 / 2 " R E B A R W I T H R I B B O N & SM A S H E D C A P 0 . 3 7 ' S W O F C O R N E R (NE W C O R N E R N O T S E T ) FND. 1/2" REBAR WITH RIBBON & BROKEN CAP FND. 1 / 2 " R E B A R WYC # 1 5 9 8 0 CONCRE T E S U R F A C E CONCRE T E S U R F A C E ASPHALT S U R F A C E INTE R S T A T E P A R K W A Y R2 2 / U T E A V E S74° 24 ' 2 5 " W 360.00' S 2 ° 2 0 ' 1 8 " E 30 . 4 9 ' S35 ° 5 0 ' 1 3 " W 16 3 . 6 4 ' C9 C7 ROADWAY EASEMENT BK 456 PG 93 10' P U E BK 2 0 1 7 P G 2 3 1 9 3 15' SSE BK 2017 PG 23193 10' WATERMAIN EASEMENT BK 2017 PG 23193 8.00' 10' PUE BK 2017 P G 2 3 1 9 3 30' SET B A C K L I N E 30 ' S E T B A C K L I N E 30' PL A T T E D S E T B A C K L I N E 30' P L A T T E D S E T B A C K L I N E PROPOSED 35'x10' TEMP. GRADING EASEMENT 20' STORM SEWER & OVERLAND FLOWAGE EASEMENT BK 2017 PG 23193 20.00 PROP O S E D BUILD I N G 16,200 S F F.F. EL E V . 1 0 0 1 . 5 0 6 SPA C E S @ 9 ' x 1 7 ' 9 SPA C E S @ 9 ' x 1 7 ' 9 SPA C E S @ 9 ' x 1 7 ' 9 SPA C E S @ 9 ' x 1 7 ' INCLU D I N G 1 A D A S P A C E 8 SPA C E S @ 9 ' x 1 7 ' INCLU D I N G 1 A D A S P A C E 7 SPA C E S @ 9 ' x 1 7 ' 81.00 9.50 81.00 9.50 54.00 2 4 . 0 0 1 7 . 0 0 30.96 R4 . 0 0 R4 . 0 0 1 7 . 0 0 1 7 . 0 0 R4 . 0 0 R4. 0 0 R4 . 0 0 R4 . 0 0 63.00 9.50 81.00 9.50 90.00 1 7 . 0 0 1 7 . 0 0 R4 . 0 0 R4. 0 0 R4 . 0 0 R4 . 0 0 26.00 2 4 . 0 0 1 7 . 0 0 1 7 . 0 0 1 5 . 5 0 5 R4. 0 0 R4 . 0 0 R 2 0 . 0 0 R20 . 0 0 270.00 11.50 N1 ° 3 9 ' 3 7 " E 20 3 . 0 9 ' C8 122.12 7 . 0 0 1 7 . 0 0 6 0 . 0 0 3 0 . 0 0 2 0 . 0 0 2 6 . 9 7 5 5 5 R10 R1 0 . 0 R 1 0 . 0 0 R161.00 1 6 . 5 5 PR O P O S E D 1 0 ' P U E 10.00 R4. 0 0 24.00 44 . 0 7 1 2 1 2 1 2 1 2 8.47 101.00 6 1 . 8 8 17 . 0 1 PROPOSED DETENTION EASEMENT 1 1 . 5 0 3 0 . 0 0 20.00 90.00 10.0 20.00 2 0 . 5 0 R1 0 . 0 0 R1 0 . 0 0 16.63 2 Curve Table Curve # C9 C7 C8 Length 278.19 167.17 12.49 Radius 265.00 368.00 35.00 Delta 60°08'53" 26°01'41" 20°26'37" Chord Direction N89° 19' 03"E N72° 15' 24"E N75° 00' 52"E Chord Length 265.59' 165.74' 12.42' Tangent 153.45' 85.05' 6.31' PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: C-103 - DIMENSION SHEET 08.07.2025 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: L. BURKE J:\2025 Projects\25-010 I80 WIP Plat 1 Lot 6\Engineering\Sheet Set WAUKEE, IOWA LOT 1, INTERSTATE CROSSING 555 INTERSTATE PARKWAY TITLE: ----25-0101"=20' PRELIMINARY LEGEND: MORE OR LESS GUTTER ELEVATION TOP OF CURB ELEVATION +/- EXISTING/ PROPOSED ELEVATION 123.45G 123.45TC FLOWLINE ELEVATIONFL FINISHED FLOORF.F. 123.45123.45/ CALCULATED CORNER FOUND CORNER CONTROL POINT ELEC. TRANSFORMER ELEC. METER ELEC. BOX SIGN PARKING SPACE STREET LIGHT POWER POLE LIGHT POLE CALCULATED SECTION CORNER FOUND SECTION CORNER AREA LIGHT GUY ANCHOR ELEC. MANHOLE ELEC. VAULT GAS VALVE GAS METER UTILITY PEDESTAL CABLE TV JUNCTION BOX SANITARY SEWER MANHOLE STORM SEWER MANHOLE CLEANOUT DOWNSPOUTD SINGLE INTAKE WATER VALVE WATER TEE FLARED END SECTION FIRE HYDRANT VALVE PROPOSED UTILITY LINEP XX EXISTING UTILITY LINEE XX WATER METER THROAT INTAKE FENCE LINE FIBER OPTIC WATER GAS LINE SANITARY SEWER STORM SEWER UNDERGROUND TEL. OVERHEAD TEL. W ST UGT OHT G SAN UNDERGROUND ELEC.UGE OVERHEAD ELEC.OHE FO CABLE TELEVISIONCATV AREA INTAKE FL O W L I N E B R E A K L I N E B R E A K L I N E B R E A K L I N E B R E A K L I N E 4 4 4 4 4 4 4 4 £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ 4 4 4 4 £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ F L O W L I N E F L O W L I N E F L O W L I N E BREAK L I N E £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ B R E A K L I N E B R E A K L I N E E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T SPEED L I M I T 2 5 M P H & NO P A R K I N G S I G N F O V FOV FOV FO V TEL TEL STOP SIGN E S T E S T E S T E S T E S T E S T CONCRE T E S U R F A C E CONCRE T E S U R F A C E F.L. = 1001.21 12 " P V C O U T L E T P I P E FL = 1 0 0 1 . 0 2 15 " C M P AR E A I N T A K E E ST E ST E ST E ST DETENTION BASI N FL = 9 9 7 . 3 2 ST O R M M H RI M = 9 9 0 . 8 4 F.L . = 9 8 4 . 2 4 AREA IN T A K E MH RIM = 9 9 3 . 6 8 F.L. = 9 8 8 . 3 7 AREA IN T A K E GRATE = 9 9 3 . 1 0 F.L. = 98 8 . 6 1 INTE R S T A T E P A R K W A Y R2 2 / U T E A V E 986987 98 8 98 9 990 991 99 1 99 2 99 2 99 3 9 9 3 9 9 4 99 4 9959959 9 5 9 9 5 9969969 9 6 99 6 997 99 7 99 8 9 9 8 99 9 9 9 9 10 0 0 1 0 0 0 10 0 1 1 0 0 1 1 0 0 2 1 0 0 2 10 0 2 1 0 0 2 100 3 1 0 0 3 1 0 0 3 1 0 0 3 1 0 0 4 10 0 4 10 0 4 1 0 0 4 1 0 0 5 100 5 1 0 0 5 10 0 6 1 0 0 6 1 0 0 7 10 0 7 1 0 0 1 10 0 2 10 0 2 10 0 2 1003 10 0 3 10 0 3 10 0 4 1004 10 0 4 1005 1005 10 0 5 990 99 1 99 2 993 994 99 5 99 6 9 9 7 9 9 8 9 9 9 1000 1 0 0 1 1 0 0 2 1 0 0 3 10 0 4 10 0 4 988 989 98 9 989 990 99 0 990 99 1 991991 99 2 99 3 99 4 99 5 99 6 9 9 7 99 8 99 9 10 0 0 10 0 1 10 0 2 100 3 10 0 4 10 0 4 1 0 0 4 10 0 5 10 0 5 100 5 10 0 5 - 1 . 5 % 0.0% -6. 8 % -4 . 5 % - 2 . 5 % - 2 . 1 % 15" R C P P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST -2 5 . 3 % -4.8% -22 . 4 % -2 5 . 0 % -2.0% -4.7 % - 1 8 . 0 % - 1 6 . 4 % -2 5 . 0 % -7 . 5 % -2.7 % -3 3 . 3 % 0.0% - 1 . 5 % F.L. = 1000.88 1 8 . 6 7 ROADWAY EASEMENT BK 456 PG 93 10' P U E BK 2 0 1 7 P G 2 3 1 9 3 15' SSE BK 2017 PG 23193 10' WATERMAIN EASEMENT BK 2017 PG 23193 8.00' -9. 8 % 10' PUE BK 2017 P G 2 3 1 9 3 989 989 990 991 992 993 994 995 98 9 989 99 0 990 991 992 992 1000 1001 1002 1003 1004 9 9 7 9 9 8 9 9 9 1 0 0 0 1 0 0 1 10021002 1002 10 0 3 10 0 1 10 0 1 100 1 1 0 0 2 10 0 3 10 0 3 100 3 10 0 4 10 0 4 100 1 10 0 1 1 0 0 1 10 0 1 1002 10 0 2 1003 10 0 3 10 0 4 1004 1004 1005 - 1 8 . 4 % -4. 5 % 1.2% PROPOSED 35'x10' TEMP. GRADING EASEMENT 20' STORM SEWER & OVERLAND FLOWAGE EASEMENT BK 2017 PG 23193 PROP O S E D BUILD I N G 16,200 S F F.F. EL E V . 1 0 0 1 . 5 0 12" VERTICAL PVC INV. = 985.33 GROUND EL. = 985.93 P S T P S T P S T P S T P ST P ST P S T P S T P S T P S T -19.3% -13. 5 % -4.7 % -4.5% - 2 0 . 9 % -3.6% - 1 . 8 % -1 . 8 % -1. 8 % - 3 . 0 % -1.8%-1. 8 % -3 . 4 % - 2 . 3 % - 2 . 3 % - 2 9 . 6 % - 2 4 . 8 % 6 . 7 3 7 . 1 3 6.79 7 . 6 1 8 . 2 3 5.43 7 . 3 4 PR O P O S E D 1 0 ' P U E 9 9 7 9 9 8 999 1 0 0 0 1000 1001 1002 1003 10 0 1 10 0 2 10 0 3 10 0 4 992 993 994 995 996 9 9 7 998 999 1 0 0 0 1 0 0 1 1 0 0 2 1 0 0 3 1 0 0 4 9 9 1 9 9 2 9 9 3 9 9 4 9 9 5 989 990 99 1 - 6 . 7 % 1005 10.00 98 8 £¤ £¤£¤ £¤£¤ £¤£¤ £¤ £¤£¤ BREAKLINE 4444 PROPOSED DETENTION EASEMENT 46' x 6" DEEP OVERFLOW ELEV: 989.50' OUTLET PIPE FLOWLINE TOP OF POND: 992.50 100 YEAR POND: 990.96 30' x 6" DEEP OVERFLOW ELEV: 991.00' 100-YR PONDING ELEV. 1000.86 100-YR PONDING ELEV. 1000.85 100-YR PONDING ELEV. 1000.74 100-YR PONDING ELEV. 999.83 100-YR PONDING ELEV. 999.67 100-YR PONDING ELEV. 998.43 100-YR PONDING ELEV. 996.17 OVERFLOW ELEV: 1001.20' OVERFLOW ELEV: 1001.03' OVERFLOW ELEV: 1001.20' OVERFLOW ELEV: 1000.37' OVERFLOW ELEV: 1000.37' OVERFLOW ELEV: 998.13' OVERFLOW ELEV: 996.21 100-YR PONDING ELEV. 1000.14 OVERFLOW ELEV: 1000.46 5 . 0 5 100-YR PONDING ELEV. 1001.00 - 2 6 . 0 % -1 7 . 5 % -2 4 . 6 % OVERFLOW ELEV: 1001.30 999 1000 1000.71G 1000.81G 1000.61G 1000.35G 1000.25G 1000.07G 1000.08G 1000.27G 1000.27G 1000.08G 1000.71G 1000.71G 998.13G 998.43G 1000.90G 1000.90G 1000.90G 998.87G 997.79G HP 996.60G 996.48G 994.17G 995.74G 995.82G 1000.77G 1001.20G 1001.50G 990.72 990.75 1004.27 1004.29 LP 999.85G 996.56G 997.86995.91 997.94 998.01 1000.58 999.60 990.62 1002.19 1004.92 1004.79 998.57G 996.89G 997.94 HP 998.74G 996.68G 999.65G 999.64G LP 1000.60G 1004.99 HP 1000.61G HP 1000.37G 1001.50 996.98G 998.66G 998.73 998.81 1000.03 996.55 996.62 996.01 1000.90G 1000.71G HP 1000.61G HP 1000.37G 1000.27G 1000.08G 1000.27G 1000.08G 1000.90G 1000.25G 1000.01G 1000.10 LP 995.67G 1000.35G HP 1000.46G HP 1000.57G 1000.27G HP 1001.50G HP 1001.50 HP 1001.03 LP 1000.60G 1001.50 HP 1001.50 HP 1001.20G LP 1000.60G 1001.50 LP 999.67G LP 999.47G LP 998.09G 1001.50 1001.50 1001.30 1000.83 1000.04G 999.96G BOW: 1004.77 TOW: 1005.50 TOW: 1004.99 BOW: 1004.86 BOW: 1000.95 HP 995.95G 998.16G BOW: 996.21 BOW: 991.01 BOW: 991.41 1000.90G 1000.71G 1001.50 1001.50 996.46G HP 1001.20G HP 1000.90 997.42G 998.91G 1000.54G 1000.08G BOW: 1000.37 BOW: 999.39 BOW: 991.62 BOW: 991.58 BOW: 991.49 TOW: 1002.00 TOW: 1002.50 TOW: 1002.00 1000.86 1001.50 1000.76 1000.71G 1001.01G 1001.16G 1001.44G 1001.29G 1001.09G -3.5% -2 . 0 % - 2 3 . 5 % 5 . 4 3 9 9 7 £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ £¤ BREAKLINE -1 . 1 % 2.8% 2.6%-1 . 9 % - 1 . 5 % - 1 . 5 % 1.0% 1.2% 3.1% 3.2%-1 . 9 % -1 . 5 % 9 9 7 9 9 8 9 9 9 1 0 0 0 1 0 0 1 1002 -1.3% -1.5% - 1 . 5 % - 1 . 7 % - 1 . 4 % - 1 . 4 % 1.5% 1.3% 5 . 3 % 5 . 4 % 1.0% 1 . 5 % 1 . 4 % 1.5% 1.6% 1 . 4 % 1 . 3 % 1.5% 1.5% - 1 . 5 % 1.0% 1.2% 6 . 1 % 6 . 1 % - 1 . 4 % -6.3% -6.3% 0.0% - 1 . 5 % 1.2% - 1 . 5 % - 1 . 5 % - 1 . 5 % - 1 . 5 % -8.0% -8.0% 0.0% -8.0% -0.0% -8.0% - 1 . 5 % - 1 . 5 % - 1 . 5 % - 1 . 5 % -8.0% 0.0% -8.0% -8.0% -8.0% -0.0% SIDEWALK LANDING SIDEWALK RAMP PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: C-201 - GRADING SHEET 08.07.2025 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: L. BURKE J:\2025 Projects\25-010 I80 WIP Plat 1 Lot 6\Engineering\Sheet Set WAUKEE, IOWA LOT 1, INTERSTATE CROSSING 555 INTERSTATE PARKWAY TITLE: ----25-0101"=20' PRELIMINARY LEGEND: MORE OR LESS GUTTER ELEVATION TOP OF CURB ELEVATION +/- EXISTING/ PROPOSED ELEVATION 123.45G 123.45TC FLOWLINE ELEVATIONFL FINISHED FLOORF.F. 123.45123.45/ CALCULATED CORNER FOUND CORNER CONTROL POINT ELEC. TRANSFORMER ELEC. METER ELEC. BOX SIGN PARKING SPACE STREET LIGHT POWER POLE LIGHT POLE CALCULATED SECTION CORNER FOUND SECTION CORNER AREA LIGHT GUY ANCHOR ELEC. MANHOLE ELEC. VAULT GAS VALVE GAS METER UTILITY PEDESTAL CABLE TV JUNCTION BOX SANITARY SEWER MANHOLE STORM SEWER MANHOLE CLEANOUT DOWNSPOUTD SINGLE INTAKE WATER VALVE WATER TEE FLARED END SECTION FIRE HYDRANT VALVE PROPOSED UTILITY LINEP XX EXISTING UTILITY LINEE XX WATER METER THROAT INTAKE FENCE LINE FIBER OPTIC WATER GAS LINE SANITARY SEWER STORM SEWER UNDERGROUND TEL. OVERHEAD TEL. W ST UGT OHT G SAN UNDERGROUND ELEC.UGE OVERHEAD ELEC.OHE FO CABLE TELEVISIONCATV AREA INTAKE P S A N P S A N P S A N P W P W P W 99 0 990 990 9 9 5 1 0 0 0 988 989 98 9 989 991 9 9 1 991 9 9 2 992 992 9 9 3 9 9 4 9 9 6 9 9 7 9 9 8 9 9 9 1 0 0 1 1 0 0 0 1000 1000 10 0 0 10 0 0 10 0 0 1000 1000 100 0 1 0 0 0 1005 1 0 0 5 1005 1005 1005 1005 1005 998 9 9 8 99 9 9 9 9 999 9 9 9 1001 1001 1001 1001 1001 1001 1001 1001 1002 1002 10 0 2 1 0 0 2 10021002 1002 10 0 3 1003 1003 1003 10 0 3 1 0 0 3 1 0 0 3 1003 1003 1003 1003 1003 1003 1004 1004 10 0 4 10 0 4 1 0 0 4 10 0 4 1004 1004 1004 1004 1006 99 0 9 9 5 1 0 0 0 99 1 99 2 9 9 3 9 9 4 9 9 6 9 9 7 9 9 8 9 9 9 1 0 0 1 1 0 0 2 1 0 0 3 10 0 4 1 0 0 4 1 0 0 5 1 0 0 3 1 0 0 4 1 0 0 6 1 0 0 0 10 0 0 10 0 0 1 0 0 0 100 0 1000 100 0 10 0 0 10 0 1 10 0 2 10 0 3 E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E W FIELD S P I G O T T GAS MARKER POST F O V FOV FOV FO V TEL TEL E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W IRR IRR WM E W E W 6" WATER SERVICE E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E GAS E GAS E GAS E GAS E G A S E GAS E GAS E GAS E GAS E GAS E GAS E GAS E GA S E G A S E G A S E G A S E GA S E GAS E GAS E GAS E S T E S T E S T E S T E S T E S T CONCRE T E S U R F A C E CONCRE T E S U R F A C E F.L. = 1001.21 12 " P V C O U T L E T P I P E FL = 1 0 0 1 . 0 2 15 " C M P AR E A I N T A K E SAN MH RIM = 1002.98 F.L. (N) = 992.31 F.L. (W) = 992.24 E ST E ST E ST E ST DETENTION BASI N E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W ASPHALT S U R F A C E E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E S A N E S A N E S A N E S A N E S A N FL = 9 9 7 . 3 2 SAN MH RIM = 1001.64 F.L. (E) = 991.14 F.L. (W) = 991.10 SAN MH RIM = 994.43 F.L. (E) = 983.22 F.L. (W) = 983.19 ST O R M M H RI M = 9 9 0 . 8 4 F.L . = 9 8 4 . 2 4 AREA IN T A K E MH RIM = 9 9 3 . 6 8 F.L. = 9 8 8 . 3 7 AREA IN T A K E GRATE = 9 9 3 . 1 0 F.L. = 98 8 . 6 1 INTE R S T A T E P A R K W A Y R2 2 / U T E A V E 15" R C P 12" WATE R S E R V I C E 12" WAT E R S E R V I C E 12 " W A T E R S E R V I C E P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST 5 P SAN P SAN F.L. = 1000.88 PROPOSED GAS CONNECTION ROADWAY EASEMENT BK 456 PG 93 10' P U E BK 2 0 1 7 P G 2 3 1 9 3 15' SSE BK 2017 PG 23193 10' WATERMAIN EASEMENT BK 2017 PG 23193 8.00' 10' PUE BK 2017 P G 2 3 1 9 3 SAN CO1 CASTING:1001.29 FL:994.90 PROPOSED 35'x10' TEMP. GRADING EASEMENT 20' STORM SEWER & OVERLAND FLOWAGE EASEMENT BK 2017 PG 23193 PROPO S E D G R O U N D MOUNT E D M E C H . U N I T S PROPO S E D G R O U N D MOUNT E D M E C H . U N I T S PROPO S E D G R O U N D MOUNT E D M E C H . U N I T S PROPO S E D G R O U N D MOUN T E D M E C H . U N I T S PROP O S E D BUILD I N G 16,200 S F F.F. EL E V . 1 0 0 1 . 5 0 PROPO S E D E L E C T R I C A L R O O M PROPO S E D S P R I N K L E R R I S E R R O O M PROPOSED GAS METER LOCATION P GAS P GAS P GAS CONNECT TO EXISTING 6" WATER SERVICE 12" VERTICAL PVC INV. = 985.33 GROUND EL. = 985.93 P S T P S T P S T P S T P ST P ST P S T P S T P S T P S T EXIST 6" SAN. STUB EST. FL: 983.72 6" FIRE SERVICE W/V A L V E 2" SERVICE W/VALVE P2 - 59LF 6" PVC @ 0 . 8 5 % P5 - 7 1 L F 8 " P V C @ 1 . 0 0 % CRITICAL CROSSING SAN TOP OF PIPE: 994.78 "ASSUMED" WATER BOTTOM OF PIPE: 997.90 REFER TO SHEET C-602 CRITICAL CROSSING SAN TOP OF PIPE: 994.46 GAS BOTTOM OF PIPE: 995.50 REFER TO SHEET C-602 PR O P O S E D 1 0 ' P U E SAN MH1 SW-301 RIM:1004.37 FL OUT:994.54 8" S MAINTAIN 6' DEPTH F O R E N T I R E P I P E P1 - 5LF 6" PVC @ 2.00% FIELD VERIFY LOCATION AND DEPTH OF SERVICE MAINTAIN 6" OF VERTICAL SEPARATION BETWEEN SERVICES 10.00 RELOCATED HYDRANT ASSEMBLY CRITICAL CROSSING WATER BOTTOM OF PIPE: 998.30 GAS TOP OF PIPE: 995.50 REFER TO SHEET C-602 PROPOSED BIOSWALE PROPOSED BIOSWALE P W P W P W P W P W EXISTING MH1 STANDARD SW-301 RIM:1003.19 FL OUT:993.63 8" S 155 LF 6" WATER SERVICE CRITICAL CROSSING SAN TOP OF PIPE: 994.99 "ASSUMED" WATER BOTTOM OF PIPE: 997.90 FL IN:993.83 8" N FL IN: 994.40 6" W (CONNECTIONS TO BE CORE DRILLED AND HAVE WATER TIGHT SEAL) PROPOSED DETENTION EASEMENT 19 LF UGE PROPOSED ELECTRICAL TRANSFORMER CRITICAL CROSSING STM TOP OF PIPE: 990.61 WATER BOTTOM OF PIPE: 991.00 P6 - 77 L F 1 2 " H D P E @ 1 . 4 3 % P7 - 12 9 L F 1 2 " H D P E @ 1 . 4 3 % P1 - 80 L F 1 2 " H D P E @ 1 . 0 0 % P2 - 80 L F 1 5 " H D P E @ 1 . 0 0 % P3 - 9 3 L F 1 5 " H D P E @ 1 . 5 0 % P4 - 17LF 15" HDPE @ 6.20% STM2 SW-505 GRATE:1000.35 FL IN:994.55 12" E FL OUT:994.45 15" W STM3 SW-501 GRATE:1000.35 FL IN:993.65 15" E FL OUT:993.55 15" SW STM4 SW-501 GRATE:999.85 FL IN:992.16 15" NE FL OUT:992.06 15" S STM8 SW-501 GRATE:995.67 FL IN:989.14 12" E FL OUT:989.05 18" W STM6 SW-501 GRATE:999.47 FL IN:992.50 12" E FL OUT:992.40 12" W STM5 SW-501 GRATE:999.67 FL IN:993.70 12" NE FL OUT:993.60 12" W P8 - 69LF 12" HDPE @ 1.9 0 % P9 - 15LF 18" HDPE @ 0.33% FES2 FL:989.00 P12 - 5 8 L F 6 " H D P E @ 3 . 4 4 % STM9 24" STRUCTURE OVERFLOW CLEANOUT:991.00 FL IN:986.00 6" NE FL IN:986.00 6" E FL OUT:986.00 15" W MH2 SW-401 RIM:990.89 FL IN:985.43 15" E FL OUT:985.33 15" SW P5 - 5 6 L F 1 2 " H D P E @ 1 . 4 2 % P1 0 - 6 6 L F 1 2 " H D P E @ 1 . 4 4 % P1 1 - 9 2 L F 6 " H D P E @ 2 . 1 8 % STM7 SW-501 GRATE:998.09 FL IN:990.55 12" E FL OUT:990.45 12" W MH1 SW-401 GRATE:1001.84 FL IN:994.60 12" N FL OUT:994.50 12" SW STM10 SW-512 GRATE:1000.55 FL OUT:995.55 12" S 5"x24" ORIFICE ELEV: 989.61 3" ORIFICE FL: 986.01 P13 - 31LF 15" HDPE @ 1.82% STM1 SW-505 GRATE:1000.35 FL OUT:995.35 12" W CO1 RIM:991.00 FL:988.00 CO2 RIM:989.00 FL:988.00 FES 1 FL:991.02 CONNECT PROPOSED SAN PIPES TO THE MAIN WITH A WYE NOT THE MANHOLE PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: C-301 - UTILITY SHEET 08.07.2025 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: L. BURKE J:\2025 Projects\25-010 I80 WIP Plat 1 Lot 6\Engineering\Sheet Set WAUKEE, IOWA LOT 1, INTERSTATE CROSSING 555 INTERSTATE PARKWAY TITLE: ----25-0101"=20' PRELIMINARY LEGEND: MORE OR LESS GUTTER ELEVATION TOP OF CURB ELEVATION +/- EXISTING/ PROPOSED ELEVATION 123.45G 123.45TC FLOWLINE ELEVATIONFL FINISHED FLOORF.F. 123.45123.45/ CALCULATED CORNER FOUND CORNER CONTROL POINT ELEC. TRANSFORMER ELEC. METER ELEC. BOX SIGN PARKING SPACE STREET LIGHT POWER POLE LIGHT POLE CALCULATED SECTION CORNER FOUND SECTION CORNER AREA LIGHT GUY ANCHOR ELEC. MANHOLE ELEC. VAULT GAS VALVE GAS METER UTILITY PEDESTAL CABLE TV JUNCTION BOX SANITARY SEWER MANHOLE STORM SEWER MANHOLE CLEANOUT DOWNSPOUTD SINGLE INTAKE WATER VALVE WATER TEE FLARED END SECTION FIRE HYDRANT VALVE PROPOSED UTILITY LINEP XX EXISTING UTILITY LINEE XX WATER METER THROAT INTAKE FENCE LINE FIBER OPTIC WATER GAS LINE SANITARY SEWER STORM SEWER UNDERGROUND TEL. OVERHEAD TEL. W ST UGT OHT G SAN UNDERGROUND ELEC.UGE OVERHEAD ELEC.OHE FO CABLE TELEVISIONCATV AREA INTAKE 4.5'4.5'6' 4:1 Slo p e 4:1 S l o p e 9" MODIFIED SOIL LAYER BIOSWALE CROSS SECTION DETAIL 4'4' 3" CHOKER LAYER 12" STONE AGGREGATE SUBBASE LAYER 6" SUBDRAIN OUTLINE OF SIDE SLOPE W/ 2' BURY DEPTH AND KEYED 4' INTO SLOPESTAGE 986.00 988.0:GROUND SURFACE AT THE STRUCTURE 991.00 SANITARY SERVICE RISER PROFILE FIELD VERIFY EXACT LOCATIONS NOTE: -BIO SWALE AREA CALCULATIONS: WQV REQUIRED: 4872 CF WQV PROPOSED: 4872 CF BIOSWALE MATERIAL DETAILS: ·THE 9" MODIFIED SOIL LAYER CONSISTS OF BIOMEDIA. THIS LAYER CONSISTS OF A UNIFORM MIXTURE OF 75% WASHED CONCRETE SAND, 10% APPROVED ORGANIC MATERIAL, 15% SOIL WITH A SOIL TEXTURE THAT INCLUDED A-HORIZON CHARCTERISTICS AND MEETS SPECIFICATIONS. ·THE CHOKER LAYER CONSISTS OF CLEAN, DURABLE 3 8 INCH DIAMETER CHIP. ·THE 12" STONE AGGREGATE SUBBASE CONSISTS OF WASHED 2 INCH DIAMETER CLEAR STONE, WITH A POROSITY OF 40%. -PERMANENT FLEXSTORM FILTER BAGS TO BE INSTALLED ON ALL AREA INTAKES WITHIN THE PROPERTY. MAINTENANCE: 1. Inspection should occur following rain events >½”. (> 12.5 mm) 2. Temporary use filters should be monitored accordingly to current site runoff conditions. 3. Permanent use filter inspections to occur a minimum of 3 times per year and in snowfall affected regions, inspections prior to and after snowfall season. 4. Industrial application site inspections (loading ramps, wash racks & maintenance facilities) to be scheduled on a recurring basis no less than 4 times per year or as needed. PRO P O S E D 5 ' S I D E W A L K 99 0 990 990 9 9 5 1 0 0 0 988 989 98 9 989 991 9 9 1 991 9 9 2 992 992 9 9 3 9 9 4 9 9 6 9 9 7 9 9 8 9 9 9 1 0 0 1 1 0 0 0 1000 1000 10 0 0 10 0 0 10 0 0 1000 1000 100 0 1 0 0 0 1005 1 0 0 5 1005 1005 1005 1005 1005 998 9 9 8 99 9 9 9 9 999 9 9 9 1001 1001 1001 1001 1001 1001 1001 1001 1002 1002 10 0 2 1 0 0 2 10021002 1002 10 0 3 1003 1003 1003 10 0 3 1 0 0 3 1 0 0 3 1003 1003 1003 1003 1003 1003 1004 1004 10 0 4 100 4 1 0 0 4 10 0 4 1004 1004 1004 1004 1006 99 0 9 9 5 1 0 0 0 99 1 99 2 9 9 3 9 9 4 9 9 6 9 9 7 9 9 8 9 9 9 1 0 0 1 1 0 0 2 1 0 0 3 10 0 4 1 0 0 4 1 0 0 5 1 0 0 3 1 0 0 4 1 0 0 6 1 0 0 0 10 0 0 10 0 0 1 0 0 0 100 0 1000 100 0 10 0 0 10 0 1 10 0 2 10 0 3 E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T FIELD S P I G O T SPEED L I M I T 2 5 M P H & NO P A R K I N G S I G N T STOP SIGN 6" WATER SERVICEE S T E S T E S T E S T E S T E S T CONCRE T E S U R F A C E CONCRE T E S U R F A C E E ST E ST E ST E ST ASPHALT S U R F A C E INTE R S T A T E P A R K W A Y R2 2 / U T E A V E PROPO S E D 5 ' S I D E W A L K 12" WAT E R S E R V I C E 12" WAT E R S E R V I C E 12 " W A T E R S E R V I C E P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST POST CONSTRUCTION FACILITY PROP O S E D BUILD I N G 16,200 S F F.F. EL E V . 1 0 0 1 . 5 0 P R O P O S E D 5 ' S I D E W A L K P S T P S T P S T P S T P ST P ST P S T P S T P S T P S T PROPOSED BIOSWALE PROPOSED BIOSWALE HANDRAILS REQ. 3" FINE SHREDDED HARDWOOD MULCH FILTER SOCK/SILT FENCEXX PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: C-401 - EROSION CONTROL SHEET 08.07.2025 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: L. BURKE J:\2025 Projects\25-010 I80 WIP Plat 1 Lot 6\Engineering\Sheet Set WAUKEE, IOWA LOT 1, INTERSTATE CROSSING 555 INTERSTATE PARKWAY TITLE: ----25-0101"=20' PRELIMINARY LEGEND: MORE OR LESS GUTTER ELEVATION TOP OF CURB ELEVATION +/- EXISTING/ PROPOSED ELEVATION 123.45G 123.45TC FLOWLINE ELEVATIONFL FINISHED FLOORF.F. 123.45123.45/ CALCULATED CORNER FOUND CORNER CONTROL POINT ELEC. TRANSFORMER ELEC. METER ELEC. BOX SIGN PARKING SPACE STREET LIGHT POWER POLE LIGHT POLE CALCULATED SECTION CORNER FOUND SECTION CORNER AREA LIGHT GUY ANCHOR ELEC. MANHOLE ELEC. VAULT GAS VALVE GAS METER UTILITY PEDESTAL CABLE TV JUNCTION BOX SANITARY SEWER MANHOLE STORM SEWER MANHOLE CLEANOUT DOWNSPOUTD SINGLE INTAKE WATER VALVE WATER TEE FLARED END SECTION FIRE HYDRANT VALVE PROPOSED UTILITY LINEP XX EXISTING UTILITY LINEE XX WATER METER THROAT INTAKE FENCE LINE FIBER OPTIC WATER GAS LINE SANITARY SEWER STORM SEWER UNDERGROUND TEL. OVERHEAD TEL. W ST UGT OHT G SAN UNDERGROUND ELEC.UGE OVERHEAD ELEC.OHE FO CABLE TELEVISIONCATV AREA INTAKE STAGI N G A R E A D U M P S T E R C o n c r e t e W a s h o u t T E M P S A N I T A R Y F A C I L I T Y C O N T A I N M E N T A R E A CO N S T R U C T I O N EN T R A N C E 2 0 X 5 0 TOPS O I L STORA G E SWPPP NOTES: 1.LOCATION OF STAGING AREAS TO CONTAIN: JOB TRAILERS, FUELING LOCATION, TEMPORARY SANITARY FACILITIES, MATERIALS STORAGE, CONCRETE WASHOUT AREA. CONTROL RUNOFF WITH DIVERSION BERMS OR SILT FENCE AND DIRECT TO SEDIMENT BASIN WHERE POSSIBLE. 2.ALL INTERIOR & PERIMETER SILT FENCE NOT SHOWN. SEE EROSION CONTROL PLAN. 3.MULCH OR SOD ALL DISTURBED AREAS NOT PAVED OR DEVELOPED. 4.ADDITIONAL CONTROLS MAY BE REQUIRED DEPENDING ON PHASING & SITE CONDITIONS. CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING, NOTING & IMPLEMENTING. 5.A MINIMUM 6" LAYER OF TOPSOIL SHALL BE RESPREAD FROM THE STOCKPILE ONSITE TO SODDED PERVIOUS SURFACES THAT WERE DISTURBED DURING CONSTRUCTION. SEEDED AREAS TO RECEIVE A MINIMUM 8" OF TOPSOIL 6.ALL BARE AREAS THAT WILL REMAIN INACTIVE FOR 14 DAYS OR MORE REQUIRE IMMEDIATE STABILIZATION MEASURES (TEMPORARY SEEDING OR MULCHING). MIXING TYPE 4B. 7.ALL SLOPES 4:1 OR GREATER REQUIRE SODDING AND MATTING 8.To effectively control erosion from sawcutting and slurry, contain the slurry to the immediate work area using methods like sandbags, temporary berms, or other containment structures, and prevent runoff from entering storm drains. 8.1. Containment and Prevention of Runoff: Confine Slurry: Use sandbags, temporary berms, or other containment structures to prevent slurry and sediment from spreading beyond the immediate work area. Block Storm Drain Inlets: If the sawcutting area is near a storm drain inlet, block the inlet with sandbags or equivalent temporary measures to prevent slurry from entering the drain. Remove Sandbags Promptly: After completing sawcutting operations, remove the sandbags to prevent drainage problems during storm events. Prevent Slurry from Drying: Do not allow slurry and cuttings to remain on the pavement to dry out. 8.2. Slurry Collection and Disposal: Vacuum or Recover Slurry: Continuously vacuum or otherwise recover slurry and cuttings during sawcutting operations to prevent discharge from the site. Designated Disposal Areas: Develop pre-determined, safe slurry disposal areas. Immediate Hauling or Onsite Containment: Collected slurry and cuttings should be immediately hauled from the site for disposal at a waste facility or discharged into onsite containment. Onsite Containment: If immediate hauling is not possible, the onsite containment may be an excavated or bermed pit lined with plastic. 9. OWNERSHIP/MAINTENANCE OF DETENTION (POST-CON) FACILITIES IS THE RESPONSIBILITY OF: PARAMOUNT LAND COMPANY 2540 73RD STREET URBANDALE, IA. 50322 (515) 333-1954 10. NEAREST BODY OF WATER IS JOHNSON CREEK. 11. BIOSWALE FACILITIES ARE TO BE INSTALLED ONCE ALL UPSTREAM AREAS HAVE BEEN ESTABLISHED WITH PERMANENT VEGETATION. FINAL DISCHARGE FINAL DISCHARGE FINAL DISCHARGE REFER TO SWPPP NOTE #8 NOTE: -PERMANENT FLEXSTORM FILTER BAGS TO BE INSTALLED ON ALL AREA INTAKES WITHIN THE PROPERTY. MAINTENANCE: 1. Inspection should occur following rain events >½”. (> 12.5 mm) 2. Temporary use filters should be monitored accordingly to current site runoff conditions. 3. Permanent use filter inspections to occur a minimum of 3 times per year and in snowfall affected regions, inspections prior to and after snowfall season. 4. Industrial application site inspections (loading ramps, wash racks & maintenance facilities) to be scheduled on a recurring basis no less than 4 times per year or as needed. PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: C-601 - DETAIL SHEET 08.07.2025 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: L. BURKE J:\2025 Projects\25-010 I80 WIP Plat 1 Lot 6\Engineering\Sheet Set WAUKEE, IOWA LOT 1, INTERSTATE CROSSING 555 INTERSTATE PARKWAY TITLE: ----25-010NTS PRELIMINARY 15) BOLLARD DETAIL (-)4'-0" BELOW FINISH GRADE PARKING LOT PAVING REF CIVIL OVER EXCAVATE 1 TO 2 FEET HORIZONTALLY BELOW FROST DEPTH IN YOUR AREA. 4" STEEL, CONCRETE FILLED BOLLARD W/ PLASTIC COVER. REF. CIVIL PLANS FOR LOCATION. (-)2'-10" B.O. Pipe Bollard 2'-5" T.O. Pipe Bollard 1/2" EXPANSION 'ZIP' STRIP (TYP) 11) SW-501 SINGLE GRATE INTAKE Length, L Wi d t h , W Pi p e D i a m e t e r , D 3D T 10) 9040.110 FLAT RIP RAP OUTLET Depth 8" min. Class I Bedding Material 8" min 27" dia 12) SW-401 STORM SEWER MANHOLE 14) SITE SPECIFIC TRANSFORMER PAD Three-phase transformer pads must be: 1. Installed by the customer at the customer's expense. Ongoing maintenance and repair to the pad are the responsibility of the customer. 2. Constructed in a manner satisfactory to the Company, in a mutually agreed upon location with hard surface access and unobstructed work space for large vehicles. 3. The installation of a screening or barrier structure may be required by your local governing authority. It is the customer’s responsibility to determine if a barrier structure is required. If screening or a barrier structure is required, or installed as an optional feature, the clearance limitations of notes 2 and 3 must be maintained. 4. A 3’-0” minimum clearance is to be maintained from pad sides and back, to the nearest structure or plantings. A level graded, 10’-0” minimum clearance is to be maintained from the front of pad, to the nearest fixed structure or plantings. If a full length gate is installed, it shall be hinged and no closer than 3’-0” from pad front. Local government, fire protection, and building codes may require greater clearances. Customer will avoid plantings or construction that interferes with Company’s required maintenance access to its equipment. If a fence or barrier is to be installed, it must be coordinated with the Company. 5. All conduits shall extend 5’-0” beyond the pad and screening structure (if used) and the locations of the ends of primary conduits shall be identified. Primary conduit shall be installed between 42” and 48” below final grade. Secondary conduit shall be installed between 30” and 42” below final grade. 6. When metallic conduit is utilized, customer shall install grounding bushings. 7. When necessary for traffic protection, set a 4” diameter concrete-filled galvanized steel post 3’-0” from pad corner. Post shall be 8’ long with a 4’ concrete embedment. 8. All Company transformers shall be located in mutually agreed upon location with hard surface access and unobstructed work space for large vehicles. If special equipment, such as a crane, is required for setting or replacing the transformer, the customer shall pay all expenses. 9. A trench 2’-0” deep and 3’-0” wide will be dug on all four sides. The trench will be lined with silt fence fabric and filled with 3” screened river rock to final grate. Contact local engineering representative if design needs modification. GATE SEE NOTE 4 10' - 0" MIN. SEE NOTE 4 3' - 0" MIN. SEE NOTE 4 3" RIVER ROCK BUILDING WALL, BARRIER WALL OR SCREENING STRUCTURE. SEE NOTE 3 FRONT OF PAD PRIMARY SECONDARY PAD REINFORCEMENT MOAT SEE NOTE 9 GROUND ROD SLEEVE 1" METERING CONDUIT MAY BE REQUIRED CABLE CONDUIT BOX-OUTS. CONDUITS SHALL BE CENTERED ALONG THE BACK EDGE WITHIN BOX-OUTS TRAFFIC PROTECTION POSTS (BY CUSTOMER-AS REQUESTED BY COMPANY) SEE NOTE 7 16' - 6" 11' - 0" 1 2 3 4 5 6 7 86" Class I Bedding OUTLET STRUCTURE 3 6" min. Concrete Base 1 Va r i e s 4 5 15" HDPE FL = 986.00' 13) STM9 24" STRUCTURE [DETENTION OUTLET] 7 4 2 3 Curb o p e n i n g Drivew a y w i d t h Drivew a y w i d t h Curb o p e n i n g 3'-0" min. 18"12" 1'-0" m i n . 1'-0" m i n . 1'-0" (Residential/Agricultural Only) 6 Drop Curb Heights - Residential: 0" to 2" Commercial/Industrial: 112" to 3" 2) 7030.101 - CONCRETE DRIVEWAY - TYPE A 5) 9040-103 ROLLED EROSION CONTROL PRODUCT 6" m i n . 6" min. 2" to 4" 2" to 6" Secure blanket to ground according to manufacturer's recommended anchoring pattern and anchor density (minimum 1.3 anchors per square yard). Install staples at 1 foot on center. 1 2 ROLLED EROSION CONTROL PRODUCT (RECP) INSTALLATION ON SLOPES 6" m i n . 6" min. Anchor Trench or Staple Check 2 2 2 2 2 Compacted Soil Backfill 6) 9040-102 FILTER BERM AND FILTER SOCK 2'-0" 10 ' - 0 " m a x . Berm shown is typical for slopes flatter than 3:1. For steeper slopes, increase berm size as directed by the Engineer. Place berm in uncompacted windrow perpendicular to the slope at locations specified in the contract documents. Filter sock diameter as specified in the contract documents. 20 0 ' - 0 " m a x . l e n g t h p e r s e c t i o n 3'- 0 " m i n . O v e r l a p 24" min. (standard) 18" min. (compact) 5' to 7' (standard) 3' to 5' (compact)1 1 Filter berm size (standard or compact) as specified in the contract documents. 1 FILTER BERM AND FILTER SOCK 7) 9040-119 SILT FENCE SH E E T 1 O F 2 FI G U R E 9 0 4 0 . 1 1 9 SILT FENCE 2 22 installed continuously through the J-hook. terminate and restart at the J-hook or may be contractor's option, the silt fence may construct a 'J-Hook' to contain runoff. At the fence up the slope for 20 feet as shown to downstream end of each run, turn the silt a maximum run length of 100 feet. At the Install silt fence for perimiter control with ground line). inches deep (fabric may be folded below the Insert 12 inches of fabric a minimum of 6 installed continuously through the J-hook. terminate and restart at the J-hook or may be the contractor's option, the silt fence may the slope for a length of 20 feet as shown. At contain runoff by turning the silt fence up the end of each run, construct a 'J-Hook' to elevation for a maximum run of 200 feet. At Place silt fence continuously along a constant adequately support fence. concentration areas, or as required to Reduce post spacing to 5 feet at water 4 4 Ground Contours required on a slope. to the ground contour when Install silt fence parallelSilt FenceSilt Fence Ground Line Fabric Post Cable Ties Wire or 4 3 1 3 1 1 1 1 FlowFlow Area to be Protected TYPICAL SILT FENCE INSTALLATION FOR PERIMITER CONTROL Flow Flow Flow Flow DETAILS OF SILT FENCE ON LONGITUDINAL SLOPES (Plan View) (Profile View) TYPICAL SILT FENCE INSTALLATION ON LONGITUDINAL SLOPES TYPICAL SILT FENCE INSTALLATION ON LONGITUDINAL SLOPES ATTACHMENT TO POSTTYPICAL SILT FENCE DITCH CHECK 20" min. 8) 9040-105 WATTLE 4'-0" m a x . 4'- 0 " m a x . 20 0 ' - 0 " m a x . l e n g t h p e r s e c t i o n 1'- 0 " m i n . O v e r l a p WATTLE 9) STABILIZED CONSTRUCTION ENTRANCE FI G U R E 9 0 4 0 . 1 2 0 SH E E T 1 O F 1 STABILIZED CONSTRUCTION EXIT Le n g t h 20'-0 " m i n . 10'-0 " m i n . Stone Exit: 50 foot minimum length (30 foot for single family residential), or as specified in the contract documents. Length of exit may be increased if sediment track-out occurs. Manufactured Track-Out Pad: Minimum length of 35 feet or 3 times the circumference of the largest tire that will cross its path (whichever is larger). Extend length if adequate track out control is not acheived. Le n g t h 2 1 Engineering Fabric 36'-0 " m i n . 24'-0 " m i n . 1 2 3 1 2 2 3 Place bedding and backfill material as required for sewer main. Service Line Slope: 4 inch: 2% to 5% 6 inch and greater: 1% to 5% If service riser slope is steeper than 1:1, construct riser of entire service line with schedule 40 PVC (ASTM D 1785) or ductile iron (AWWA C151, Class 52). Use single length of pipe for riser, if possible. 10' Location Post 10' to 12' Cap or PlugSlope Service Line Sanitary Sewer Main Service Line Tee or Wye Service Riser Class I Bedding Material Slop e Support Bench 18'' min. Slope 3) SW-201 SANITARY SEWER STUB W/ RISER A A 8" min. Class I Bedding Material 4) SW-505 DOUBLE GRATE INTAKE 30" Minimum 4.5"3" 1) PROPOSED P.C.C. PAVEMENT / CURB 6" SUBDRAIN FL = 986.00' Weir 7 8 6SURFACE ELEV = 988.00' EL E V A T I O N STATION 25-010 Proposed Sanitary Sewer & Water Extension 995 1000 1005 1010 995 1000 1005 1010 0+00 0+75 7.84% 6.38%2.33%-0.28% -2.04% 2.57% -0.39% EXISTING MH1 STANDARD SW-301 RIM: 1003.19 FL OUT: 993.63 8" S FL IN: 993.83 8" N FL IN: 994.40 6" W CONNECT TO SANITARY WITH A WYE (CONNECTIONS TO BE CORE DRILLED) RELOCATED HYDRANT ASSEMBLY SAN MH1 SW-301 RIM: 1004.37 FL OUT: 994.54 8" S PROPOSED GAS FIELD VERIFY LOCATION AND DEPTH EXISTING WATER FIELD VERIFY LOCATION AND DEPTH P5 - 71LF 8" PVC @ 1.00% PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: C-602 - UTILITY EXTENSION PROFILE SHEET 08.07.2025 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: L. BURKE J:\2025 Projects\25-010 I80 WIP Plat 1 Lot 6\Engineering\Sheet Set WAUKEE, IOWA LOT 1, INTERSTATE CROSSING 555 INTERSTATE PARKWAY TITLE: ----25-010NTS PRELIMINARY 1 1 2 3 4 Standard duty casting complying with AASHTO M 306. Mark lid with ''Sanitary'' or ''Sanitary C.O.'' Do not allow casting to bear on top of riser pipe. 6 inch PVC Service Pipe Threaded PVC cap or iron body ferrule with brass screw plug 1 2 4 3 20'' min. Concrete Pad Plug 97 8" 7 8" 157 8"7 8" SW-203 SANITARY CLEANOUT DETAIL P S A N P S A N P S A N P W P W P W PRO P O S E D 5 ' S I D E W A L K 99 0 990 990 9 9 5 1 0 0 0 988 989 98 9 989 991 9 9 1 991 9 9 2 992 992 9 9 3 9 9 4 9 9 6 9 9 7 9 9 8 9 9 9 1 0 0 1 1 0 0 0 1000 1000 10 0 0 10 0 0 10 0 0 1000 1000 100 0 1 0 0 0 1005 1 0 0 5 1005 1005 1005 1005 1005 998 9 9 8 99 9 9 9 9 999 9 9 9 1001 1001 1001 1001 1001 1001 1001 1001 1002 1002 10 0 2 1 0 0 2 10021002 1002 10 0 3 1003 1003 1003 10 0 3 1 0 0 3 1 0 0 3 1003 1003 1003 1003 1003 1003 1004 1004 10 0 4 100 4 1 0 0 4 10 0 4 1004 1004 1004 1004 1006 99 0 9 9 5 1 0 0 0 99 1 99 2 9 9 3 9 9 4 9 9 6 9 9 7 9 9 8 9 9 9 1 0 0 1 1 0 0 2 1 0 0 3 10 0 4 1 0 0 4 1 0 0 5 1 0 0 3 1 0 0 4 1 0 0 6 1 0 0 0 10 0 0 10 0 0 1 0 0 0 100 0 1000 100 0 10 0 0 10 0 1 10 0 2 10 0 3 E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S T E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E S A N E W T F O V FOV FOV FO V TEL TEL E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W IRR IRR WM E W E W E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E G A S E GAS E GAS E GAS E GAS E G A S E GAS E GAS E GAS E GAS E GAS E GAS E GAS E GA S E G A S E G A S E G A S E GA S E GAS E GAS E GAS E S T E S T E S T E S T E S T E S T CONCRE T E S U R F A C E CONCRE T E S U R F A C E E ST E ST E ST E ST E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W ASPHALT S U R F A C E E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E SAN E S A N E S A N E S A N E S A N E S A N INTE R S T A T E P A R K W A Y R2 2 / U T E A V E PROPO S E D 5 ' S I D E W A L K P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P ST P SAN P SAN ROADWAY EASEMENT BK 456 PG 93 10' P U E BK 2 0 1 7 P G 2 3 1 9 3 15' SSE BK 2017 PG 23193 10' WATERMAIN EASEMENT BK 2017 PG 23193 8.00' 10' PUE BK 2017 P G 2 3 1 9 3 POST CONSTRUCTION FACILITY 30' SET B A C K L I N E 30 ' S E T B A C K L I N E 30' PL A T T E D S E T B A C K L I N E PROPOSED BLOCK RETAINING WALL REFER TO PLANS PREPARED BY TOMETICH ENGINEERING 30' P L A T T E D S E T B A C K L I N E PROPOSED 35'x10' TEMP. GRADING EASEMENT 20' STORM SEWER & OVERLAND FLOWAGE EASEMENT BK 2017 PG 23193 PROP O S E D BUILD I N G 16,200 S F F.F. EL E V . 1 0 0 1 . 5 0 P R O P O S E D 5 ' S I D E W A L K P GAS P GAS P GAS P S T P S T P S T P S T P ST P ST PROPOSED RETAINING WALL WITH GUARDRAIL REFER TO PLANS PREPARED BY TOMETICH ENGINEERING P S T P S T P S T P S T PR O P O S E D 1 0 ' P U E 10.00 PROPOSED BIOSWALE PROPOSED BIOSWALE P W P W P W P W P W 40.00 T Y P . 40.00 T Y P . 40.00 T Y P . 40.00 T Y P . 4 4 4 PROPOSED DETENTION EASEMENT 4 HANDRAILS REQ. SOD & IRRIGATION LIMITS 3" FINE SHREDDED HARDWOOD MULCH PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: C-701 - LANDSCAPING SHEET 08.07.2025 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: L. BURKE J:\2025 Projects\25-010 I80 WIP Plat 1 Lot 6\Engineering\Sheet Set WAUKEE, IOWA LOT 1, INTERSTATE CROSSING 555 INTERSTATE PARKWAY TITLE: ----25-0101"=20' PRELIMINARY LEGEND: MORE OR LESS GUTTER ELEVATION TOP OF CURB ELEVATION +/- EXISTING/ PROPOSED ELEVATION 123.45G 123.45TC FLOWLINE ELEVATIONFL FINISHED FLOORF.F. 123.45123.45/ CALCULATED CORNER FOUND CORNER CONTROL POINT ELEC. TRANSFORMER ELEC. METER ELEC. BOX SIGN PARKING SPACE STREET LIGHT POWER POLE LIGHT POLE CALCULATED SECTION CORNER FOUND SECTION CORNER AREA LIGHT GUY ANCHOR ELEC. MANHOLE ELEC. VAULT GAS VALVE GAS METER UTILITY PEDESTAL CABLE TV JUNCTION BOX SANITARY SEWER MANHOLE STORM SEWER MANHOLE CLEANOUT DOWNSPOUTD SINGLE INTAKE WATER VALVE WATER TEE FLARED END SECTION FIRE HYDRANT VALVE PROPOSED UTILITY LINEP XX EXISTING UTILITY LINEE XX WATER METER THROAT INTAKE FENCE LINE FIBER OPTIC WATER GAS LINE SANITARY SEWER STORM SEWER UNDERGROUND TEL. OVERHEAD TEL. W ST UGT OHT G SAN UNDERGROUND ELEC.UGE OVERHEAD ELEC.OHE FO CABLE TELEVISIONCATV AREA INTAKE PROPOSED TREES: SYMBOL #COMMON NAME SIZE (BOTANICAL NAME) 8 KENTUCKY COFFEETREE 12' TALL B&B (GYMNOCLADUS DIOICUS) 13 NORWAY SPRUCE 6' TALL B&B (PICEA ABIES) 44 DENSIFORMUS YEW 2' TALL B&B (TAXUS X MEDIA 'DENSIFORMIS') 7 "EXISTING LANDSCAPING" LANDSCAPING REQUIREMENTS: 1. MINIMUM SIZE: THE MINIMUM SIZE FOR REQUIRED PLANTINGS, OTHER THAN THOSE IN REQUIRED BUFFERS, SHALL BE AS FOLLOWS: A. DECIDUOUS OVERSTORY TREES SHALL BE A MINIMUM OF EIGHT FEET IN HEIGHT. B. EVERGREEN OVERSTORY TREES SHALL BE A MINIMUM OF SIX FEET IN HEIGHT. C. DECIDUOUS ORNAMENTAL TREES SHALL BE A MINIMUM OF SIX FEET IN HEIGHT. 2. MINIMUM QUANTITY: THE MINIMUM NUMBER OF PLANTINGS PER SITE SHALL BE AS FOLLOWS: A. A MINIMUM OF 50 PERCENT OF ALL REQUIRED TREES SHALL BE OVERSTORY SHADE TREES. B. FOR ALL USES EXCEPT SINGLE-FAMILY ATTACHED AND DETACHED RESIDENTIAL DWELLINGS, A MINIMUM OF 25 PERCENT OF ALL REQUIRED TREES SHALL BE EVERGREEN TREES. C. 1 TREE PER 1,000 SQUARE FEET OF REQUIRED OPEN SPACE AND 1 SHRUB PER 1,000 SQUARE FEET OF REQUIRED OPEN SPACE. SITE AREA*15% = 78,375 * 0.15 = 11,756 OPEN SPACE REQUIRED TREES/SHRUBS REQUIRED = 11,756 /1,000 = 11.756 TREES PROPOSED = 16 TREES SHRUBS PROPOSED = 24 SHRUBS 3. ANY SUBSTITUTIONS OR CHANGES TO LANDSCAPE PLAN SHALL BE APPROVED IN WRITING BY THE WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT. 4. BIO SWALE AREA CALCULATIONS: WQV REQUIRED: 4872 CF WQV PROPOSED: 4872 CF 5. OWNERSHIP/MAINTENANCE OF DETENTION (POST-CON) FACILITIES IS THE RESPONSIBILITY OF: PARAMOUNT LAND COMPANY 2540 73RD STREET URBANDALE, IA. 50322 (515) 333-1954 ORNAMENTAL GRASSES FOR BIOSWALE: SYMBOL #COMMON NAME SIZE (BOTANICAL NAME)(HEIGHT & SPREAD) 23 SHENANDOAH SWITCHGRASS 3'-4' & 2'-3' (PANICUM VIRGATUM 'SHENANDOAH') 39 GOLDEN JAPANESE FOREST GRASS 1.5' & 1.5' (HAKONECHLOA MACRA 'AUREOLA') 9 FOUNTAIN GRASS 2'-3' & 2'-3' (PENNISETUM ALOPECUROIDES) 25 MAIDEN GRASS 6'-8' & 3'-5' (MISCANTHUS SINENSIS 'GRACILLIMUS') TOTAL: 96 3" ORGANIC MULCH 2 1 ORIGINAL GROUND LINE PLANTING ON SLOPES PLANTING PIT TWICE THE WIDTH OF ROOTBALL SUB-SOIL DECIDUOUS SHRUB DETAIL EVERGREEN SHRUB DETAIL FIRMLY COMPACT SAUCER (USE TOPSOIL) SHRUB PLANTING (TYP) 1 STAKING 1/2 to 2/3 Tree Height (4'-0" min.) 1 Steel Post Flagging Material Flagging Material Wrap trunk from ground line to first branch when specified in the contract documents. Place one stake to southwest. Place one stake to southwest. Place one stake to southwest. 2'-0" min. STAKING PLAN (Trees 2 1/2 inch diameter or smaller) STAKING PLAN (Trees larger than 2 1/2 inch diameter) Garden Hose Planting Pit per Figure 9030.101 1/4 to 1/3 Tree Height (2'-0" min.) 3" of Organic Mulch TREE PLANTING (TYP) PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 VICINITY MAP BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: C-501 - PI COVER SHEET 08.07.2025 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: L. BURKE J:\2025 Projects\25-010 I80 WIP Plat 1 Lot 6\Engineering\Sheet Set\Public Improvements PUBLIC IMPROVEMENTS FOR INTERSTATE CROSSING 555 INTERSTATE PARKWAY WAUKEE, IOWA TITLE: C-501 - PI COVER SHEET C-502 - PLAN AND PROFILE SHEET SHEET INDEX ----25-010 C-501 - C502 WAUKEE, IOWA LOT 1, INTERSTATE CROSSING 555 INTERSTATE PARKWAY DEVELOPER PARAMOUNT LAND COMPANY 2540 73RD STREET URBANDALE, IOWA 50322 PROJECT CONTACT: NICK HALFHILL PHONE: 515-238-6649 EMAIL: NICK.HALFHILL@CASEYS.COM CITY CONTACT CITY OF WAUKEE 204 HICKMAN ROAD WAUKEE, IOWA 50325 PROJECT CONTACT: MELISSA DEBOER PHONE: (515) 978-7898 EMAIL: MDEBOER@WAUKEE.ORG ENGINEER/ LAND SURVEYOR PELDS DESIGN SERVICES 2323 DIXON ST DES MOINES, IOWA 50316 PROJECT CONTACT: ELARA JONDLE PHONE: (515) 265-8196 EMAIL: ELARA@PELDS.COM 03-11-2021 REVISIONS:LEGEND: MORE OR LESS GUTTER ELEVATION TOP OF CURB ELEVATION +/- EXISTING/ PROPOSED ELEVATION 123.45G 123.45TC FLOWLINE ELEVATIONFL FINISHED FLOORF.F. 123.45123.45/ CALCULATED CORNER FOUND CORNER CONTROL POINT ELEC. TRANSFORMER ELEC. METER ELEC. BOX SIGN PARKING SPACE STREET LIGHT POWER POLE LIGHT POLE CALCULATED SECTION CORNER FOUND SECTION CORNER AREA LIGHT GUY ANCHOR ELEC. MANHOLE ELEC. VAULT GAS VALVE GAS METER TEL. JUNCTION BOX CABLE TV JUNCTION BOX SANITARY SEWER MANHOLE STORM SEWER MANHOLE CLEANOUT DOWNSPOUTD SINGLE INTAKE WATER VALVE WATER TEE FLARED END SECTION FIRE HYDRANT VALVE PROPOSED UTILITY LINEP XX EXISTING UTILITY LINEE XX WATER METER THROAT INTAKE FENCE LINE FIBER OPTIC WATER GAS LINE SANITARY SEWER STORM SEWER UNDERGROUND TEL. OVERHEAD TEL. W ST UGT OHT G SAN UNDERGROUND ELEC.UGE OVERHEAD ELEC.OHE FO CABLE TELEVISIONCATV AREA INTAKE Parcel 20-79 as shown in the Retracement Plat of Survey filed December 18, 2020, in Book 2020, Page 35993 of the Dallas County Recorder's Office. and Lot 6 in I-80 West Industrial Park Plat 1, on Official Plat, now included in and forming a part of the City of Waukee, Dallas County, Iowa; TO BE KNOWN AS: LOT 1, INTERSTATE CROSSING LEGAL DESCRIPTION PER DEEDS: ESTIMATED QUANTITIES: STAGING 1.1 CONSTRUCTION STAKING 1 LS 1.2 MOBILIZATION 1 LS 1.3 SPREADING TOPSOIL 1 LS 1.4 TRENCH EXCAVATION 1 LS 1.5 SOD 1 LS WATER MAIN 2.1 12" DR 18 PVC PIPE 57 LF 2.2 HYDRANT ASSEMBLY 1 LS SANITARY SEWER 3.1 8" R.C.P.60 LF 3.2 SW-203 1 LS GENERAL NOTES: 1.ALL WORK SHALL BE CONDUCTED IN ACCORDANCE WITH OSHA CODES AND STANDARDS ALONG WITH THE 2025 EDITION OF SUDAS AND THE 2025 CITY OF WAUKEE SUPPLEMENTAL SPECS. NOTHING INDICATED ON THE SITE PLAN SHALL RELIEVE THE CONTRACTOR FROM COMPLYING WITH ALL APPLICABLE SAFETY REGULATIONS. 2.ALL PUBLIC IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED TO MEET THE 2025 EDITION OF SUDAS AND THE CITY OF WAUKEE SUPPLEMENTAL SPECS.. 3.THE LOCATION OF EXISTING UTILITIES AND STRUCTURES IS APPROXIMATE. THE CONTRACTOR SHALL TAKE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES AND/OR STRUCTURES AT THE SITE. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNERS OF UTILITIES AND/OR STRUCTURES TO DETERMINE THE PRESENT EXTENT AND EXACT LOCATION OF THEIR FACILITIES BEFORE BEGINNING WORK. IF EXISTING UTILITY LINES ARE ENCOUNTERED THAT CONFLICT WITH NEW CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY THE ENGINEER SO THAT THE CONFLICT MAY BE RESOLVED. 4.THE CONTRACTOR SHALL FIELD ADJUST, AS NECESSARY, ALL EXISTING UTILITIES TO FINISH GRADES. EXISTING SITE UTILITIES INCLUDE, BUT ARE NOT LIMITED TO, FIRE HYDRANTS, MANHOLE RIMS, INLETS, WATER VALVES, AND LIGHT BASES. 5.THE CONTRACTOR SHALL PRESERVE ALL MONUMENTS, STAKES, REFERENCE POINTS, AND BENCH MARKS. THE CONTRACTOR SHALL BE CHARGED THE COST FOR REPLACEMENT, LOST TIME, AND ANY OTHER ASSOCIATED RESPONSIBILITY DUE TO CONTRACTOR'S NEGLIGENCE OR CARELESSNESS THAT RESULTS IN DESTRUCTION OF THESE ITEMS. 6.ALL SPOT ELEVATIONS ARE AT THE TOP-OF-FINISHED SURFACES. 7.THE CONTRACTOR SHALL CONDUCT CLEAN-UP, SURFACE RESTORATION, AND SURFACE REPLACEMENT ACTIVITIES AS CONSTRUCTION PROGRESSES. ALL DEBRIS SPILLED ON THE ROW OR ON ADJACENT PROPERTY SHALL BE PICKED UP BY THE CONTRACTOR AT THE END OF EACH WORK DAY. 8.MATERIALS NOT SUITABLE FOR CONSTRUCTION, INCLUDING, TRENCH BACKFILL AND SURFACE RESTORATION, AND EXCESS MATERIALS SHALL BE PROPERLY DISPOSED. DISPOSAL IS INCIDENTAL TO CONSTRUCTION. 9.THE CONTRACTOR SHALL NOTIFY PROPERTY OWNERS AT LEAST 24 HOURS IN ADVANCE IF ACCESS TO PROPERTY WILL BE INTERRUPTED. ACCESS TO PRIVATE PROPERTY FOR EMERGENCY VEHICLES SHALL BE MAINTAINED AT ALL TIMES. 10.NOTIFY THE CITY OF WAUKEE, AT LEAST 48 HOURS PRIOR TO BEGINNING CONSTRUCTION ACTIVITIES (OR TO VERIFY ROW, ETC.). 11.THE CONTRACTOR SHALL COORDINATE WORK AND COOPERATE WITH CITY OF WAUKEE PERSONNEL. 12.MAINTAIN ALL CUT AND FILL AREAS FOR SURFACE DRAINAGE AT ALL TIMES. 13.ALL AREAS TO RECEIVED FILL TO BE BENCHED. 14.PREPARE BOTTOM OF BENCH FOR FILL BY DISCING TO A DEPTH OF 6 INCHES. 15.ALL SITE FILL SHALL BE COMPACTED TO A DENSITY THAT IS NOT LESS THAN 95% STANDARD PROCTOR DENSITY. 16.THE DEVELOPER AND/OR CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE THE CITY OF WINDSOR HEIGHTS WITH RECORD DRAWINGS OF ALL IMPROVEMENTS AS PER CITY STANDARD PROCEDURES. 17.INSPECTION SERVICES FOR PUBLIC IMPROVEMENTS ARE TO BE PROVIDED BY THE CITY'S ENGINEER. STREET, DRIVEWAY, AND TRAFFIC NOTES 1.THE CONTRACTOR SHALL PROVIDE TRAFFIC CONTROL FOR ALL WORK WITHIN STREET RIGHTS OF WAY AT NO ADDITIONAL COST TO THE OWNER. TRAFFIC CONTROL SHALL CONSIST OF BARRICADES, SIGNAGE, LIGHTS AND FLAGGERS AS NECESSARY TO PROTECT VEHICLE AND PEDESTRIAN TRAFFIC IN ACCORDANCE WITH THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES. 2.ALL EXISTING STREET AND TRAFFIC CONTROL SIGNS THAT ARE IN CONFLICT WITH CONSTRUCTION SHALL BE REMOVED AND RESET BY THE CONTRACTOR. OWNER SHALL DIRECT RESETTING OF SIGNS. CONTRACTOR SHALL PROVIDE NECESSARY SIGNS, BARRICADES, LIGHTS, AND FLAGMEN TO INSURE THE SAFE FLOW OF VEHICULAR AND PEDESTRIAN TRAFFIC. WORK IS INCIDENTAL TO CONSTRUCTION. 3.CONTRACTOR SHALL MINIMIZE DISRUPTION OF TRAFFIC ON INTERSTATE PARKWAY AT ALL TIMES. 4.REMOVE EXISTING STREET, PARKING, AND DRIVEWAY SURFACING IN NEAT, UNIFORM LINES. REPLACE SURFACING WITH MATERIAL NOTED AND SPECIFIED ON PLANS. PROTECT REMAINING STREET SURFACE FROM DAMAGE. 5.PAVING THICKNESSES SHALL BE AS SHOWN ON THE PLANS. 6.SUBGRADE TO BE 12-INCH THICK EARTH COMPACTED TO 95% MAX. DENSITY WITH MOISTURE CONTENT NOT MORE THAN 4% ABOVE OR 1% BELOW OPTIMUM. 7.DURING SUBGRADE PREPARATION, IN FILL AREAS, GRADE SHALL BE PROOF-ROLLED AFTER PLACEMENT OF ONE FOOT SUB-GRADE AND COMPACTION. 8.RELOCATE STREET SIGNS AT STREET INTERSECTIONS. GENERAL UTILITY NOTES: 1.ALL CONSTRUCTION IS TO BE IN ACCORDANCE WITH THE STATEWIDE URBAN STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS (SUDAS). 2.THE LOCATIONS OF THE EXISTING UTILITIES SHOWN HEREIN ARE APPROXIMATE. THEY HAVE BEEN PLOTTED FROM AVAILABLE SURVEYS AND/OR RECORDS. THE CONTRACTOR IS RESPONSIBLE TO ENSURE THAT ANY EXITING UTILITIES (SHOWN OR NOT SHOWN) ARE NOT DAMAGED DURING CONSTRUCTION. 3.ALL TRENCH BACKFILL SHALL BE 95% STANDARD PROCTOR DENSITY. PRELIMINARY SITE LOCATION I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF IOWA. _______________________________________________________ VOLDEMARS L. PELDS, P.E. IA. LIC. NO. 18842 DATE MY LICENSE RENEWAL DATE IS DECEMBER 31, 2025 ADDITIONAL PAGES OR SHEETS COVERED BY THIS SEAL (NONE UNLESS INDICATED HERE):_________________________________ ________________________________________________________ VOLDEMARS L. 18842 PELDS IOWA EL E V A T I O N STATION 25-010 Proposed Sanitary Sewer & Water Extension 995 1000 1005 1010 995 1000 1005 1010 0+00 0+75 7.84% 6.38%2.33%-0.28% -2.04% 2.57% -0.39% EXISTING MH1 STANDARD SW-301 RIM: 1003.19 FL OUT: 993.63 8" S FL IN: 993.83 8" N FL IN: 994.40 6" W (CONNECTIONS TO BE CORE DRILLED) RELOCATED HYDRANT ASSEMBLY SAN MH1 SW-301 RIM: 1004.37 FL OUT: 994.54 8" S PROPOSED GAS FIELD VERIFY LOCATION AND DEPTH EXISTING WATER FIELD VERIFY LOCATION AND DEPTH P5 - 71LF 8" PVC @ 1.00% P WP WP WP WP WP W 10 0 5 1005 1004 10 0 4 1005 1006 E SANE SANE SANE SANE SAN E WE WE WE WE W E GAS E GAS E GAS E GAS E GAS E GAS E GAS E GAS E GAS E GAS E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W E W P G A S P G A S P G A S P G A S P G A S PROPOSED 10' PUE 10 . 0 0 EXISTING MH1 STANDARD SW-301 RIM: 1003.19 FL OUT: 993.63 8" S FL IN: 993.83 8" N FL IN: 994.40 6" W (CONNECTIONS TO BE CORE DRILLED) CRITICAL CROSSING SAN TOP OF PIPE: 994.99 "ASSUMED" WATER BOTTOM OF PIPE: 997.90 CRITICAL CROSSING SAN TOP OF PIPE: 994.46 GAS BOTTOM OF PIPE: 995.50 REFER TO SHEET C-602 CRITICAL CROSSING SAN TOP OF PIPE: 994.78 "ASSUMED" WATER BOTTOM OF PIPE: 997.90 REFER TO SHEET C-602 SAN MH1 SW-301 RIM: 1004.37 FL OUT: 994.54 8" S PROPOSED GAS CONNECTION RELOCATED HYDRANT ASSEMBLY CRITICAL CROSSING WATER BOTTOM OF PIPE: 998.30 GAS TOP OF PIPE: 995.50 REFER TO SHEET C-602 FIELD VERIFY LOCATION AND DEPTH OF SERVICE MAINTAIN 6" OF VERTICAL SEPARATION BETWEEN SERVICES P5 - 71LF 8" PVC @ 1.00% P 2 - 5 9 L F 6 " P V C @ 0 . 8 5 % PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: C-502 - PLAN AND PROFILE SHEET 08.07.2025 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: L. BURKE J:\2025 Projects\25-010 I80 WIP Plat 1 Lot 6\Engineering\Sheet Set\Public Improvements WAUKEE, IOWA LOT 1, INTERSTATE CROSSING 555 INTERSTATE PARKWAY TITLE: ----25-0101" = 10' PRELIMINARY 1 1 2 3 4 Standard duty casting complying with AASHTO M 306. Mark lid with ''Sanitary'' or ''Sanitary C.O.'' Do not allow casting to bear on top of riser pipe. 6 inch PVC Service Pipe Threaded PVC cap or iron body ferrule with brass screw plug 1 2 4 3 20'' min. Concrete Pad Plug 97 8" 7 8" 157 8"7 8" SW-203 SANITARY CLEANOUT DETAIL SE-LY COR LOT 6 I-80 INDUSTRIAL PARK PLAT 1 FND. 1/2" REBAR WYC #15980 S-LY COR LOT 6 I-80 INDUSTRIAL PARK PLAT 1 FND. 1/2" REBAR WYC #15980 EXISTING ROADWAY EASEMENT BK 456 PG 93 LOT 1 INTERS T A T E P K W Y R2 2 / U T E A V E 30' SE T B A C K L I N E 30' S E T B A C K L I N E 30' SET B A C K L I N E 30 ' S E T B A C K L I N E C6 N1 ° 4 3 ' 2 0 " E 1 0 8 . 8 1 ' ( M ) N79° 59' 38" E 40.80' (M) N1 ° 4 1 ' 0 4 " E 7 3 . 3 5 ' ( M ) NW COR LOT 6 I-80 INDUSTRIAL PARK PLAT 1 FND. 1/2" REBAR W/RIBBON 0.94' ± SOUTH OF CORNER (NEW CORNER NOT SET) FND. 1/2" REBAR W/RIBBON & BROKEN CAP FND. 3/4" BENT IRON PIPE FND. 1/2" REBAR WYC #15980 0.1' ± NORTH OF PROPERTY LINE NE COR LOT 6 I-80 INDUSTRAL PARK PLAT 1 FND. 1/2" REBAR WYC #15980 POC SW COR LOT 6 I-80 INDUSTRIAL PARK PLAT 1 FND. 1/2" REBAR WITH RIBBON & SMASHED CAP 0.37' ± SW OF CORNER (NEW CORNER NOT SET) N 2 ° 2 0 ' 2 1 " W 1 5 7 . 2 9 ' ( M ) (70' RO W ) EXISTIN G 1 0 ' P U E BK 2017 P G 2 3 1 9 3 EXISTIN G 1 0 ' P U E BK 2017 P G 2 3 1 9 3 N1 ° 3 7 ' 1 1 " E 1 4 1 . 1 7 ' ( M ) NE-LY COR LOT 1 I-80 INDUSTRIAL PARK PLAT 1 FND. 1/2" REBAR EXISTING 10' WATERMAIN EASEMENT BK 2017 PG 23193 EXISTING 20' STORM SEWER & OVERLAND FLOWAGE EASEMENT BK 2017 PG 23193 1.80 AC ± PART OF LOT 2 OF THE REPLAT OF LOT 5 OF AUDITOR'S PLAT OF PART OF THE NW 1/4 NW 1/4 SECTION 17 TOWNSHIP 78 NORTH, RANGE 26 WEST STREET LOT A 0.15 AC ± LOT 6 I-80 INDUSTRIAL PARK PLAT 1 PARCE L 2 0 - 7 9 B K 2 0 2 0 P G 3 5 9 9 3 S79° 55' 49 " W 3 6 8 . 5 9 ' ( M ) C5 6,726 SQ.FT. ± 78,294 SQ.FT. ± INTERSTATE CROSSING 8'EXISTING 15' SSE BK 2017 PG 23193 EXISTING 10' WATERMAIN EASEMENT BK 2017 PG 23193 555 INTERSTATE PARKWAY 60' HALF ROW NORTH LIN E L O T 6 C4 S1 ° 2 0 ' 5 1 " W 1 3 5 . 7 4 ' ( M ) C1 C2 C3 S35 ° 5 0 ' 1 3 " W 1 6 3 . 6 4 ' ( M ) S2° 20' 18"E 30.49' (M) 359.78' ( M ) S74° 24' 2 5 " W 4 2 2 . 0 8 ' ( M ) 62.30' (M ) 10 ' P U E 10' N74° 04 ' 2 0 " E 4 2 2 . 0 6 ' ( R ) S1 ° 1 9 ' 5 5 " W 7 3 . 3 4 ' ( R ) S35 ° 2 8 ' 4 7 " W 1 6 3 . 6 4 ' ( P ) N2° 42' 49"W 30.64' (R) S1 ° 1 9 ' 5 5 " W 1 0 8 . 7 4 ' ( P ) S79° 42' 36 " W 37.62' (R) N79° 42' 36 " E 3 6 8 . 4 5 ' ( P ) S 2 ° 4 2 ' 4 9 " E 1 5 7 . 1 0 ' ( R ) LOT 5 I-80 WEST INDUSTRIAL PARK PROPOSED 35'x10' TEMP. GRADING EASEMENT PROPOSED DETENTION EASEMENT L1 N19° 36' 35"W 60.18' C 8 N0° 01' 03"W 28.18' C7 S3 5 ° 5 0 ' 1 3 " W 1 2 9 . 5 5 ' L2 POB Line Table (Detention Easement) Line # L1 L2 Direction N35° 50' 13"E S54° 09' 47"E Length 18.21' 8.00' Curve Table (M) Curve # C1 C2 C3 C4 C5 C6 C7 C8 Arc Length 12.49' 167.17' 278.19' 67.29' 69.35' 38.44' 108.80' 48.20' Radius 35.00' 368.00' 265.00' 18639.55' 18659.55' 35.00' 248.00' 136.99' Delta 20°26'37" 26°01'41" 60°08'53" 0°12'25" 0°12'47" 62°55'51" 25°08'06" 20°09'31" Chord Direction N75° 00' 52"E S72° 15' 24"W N89° 19' 03"E N2° 06' 59"E N2° 06' 00"E N33° 19' 38"E S75° 29' 08"E N10° 07' 05"W Chord Length 12.42' 165.74' 265.59' 67.29' 69.35' 36.54' 107.92' 47.95' Tangent 6.31' 85.05' 153.45' 33.64' 34.68' 21.42' 55.29' 24.35' 10' P U E 10' PROPOSED DETENTIONEASEMENT BENCHMARK: FILE PATH: REVISIONS: DRAWING NO: FINAL PLAT 7.10.2025 SCALE:LATEST REVISION:COPYRIGHT DATE:DRAWN BY: A.BRADFIELD J:\2025 Projects\25-010 I80 WIP Plat 1 Lot 6\Engineering\Sheet Set WAUKEE, IOWA INTERSTATE CROSSING FINAL PLAT 555 INTERSTATE PARKWAY TITLE: ----25-0101"=20' FINAL LEGEND: MORE OR LESS+/- SET 1/2" IRON ROD WYC #18842 (M)/(P)/(R)MEASURED/PLATTED/RECORDED FINAL PLAT INTERSTATE CROSSING DALLAS COUNTY, IOWA SEC17-T78N-R26W LEGAL DESCRIPTION: DATE OF SURVEY: 02/03/2025 RECORD INDEX: LOCATION: SEC 17-T78N-R26W REQUESTOR: PARAMOUNT LAND COMPANY REQUESTOR ADDRESS: 2540 73RD STREET URBANDALE, IA 50322 PROPRIETOR: ROBIN SOBATKA PROPRIETOR ADDRESS: 36406 SHAGBARK CIRCLE VAN METER, IA 50261 PROPRIETOR CONTACT INFORMATION: PHONE: (515)-250-3145 EMAIL: ROBIN5SOBOT@GMAIL.COM SURVEYOR: VOLDEMARS PELDS COMPANY: PELDS DESIGN SERVICES RETURN TO: 2323 DIXON STREET DES MOINES, IA 50316 PROJECT AREA: TOTAL AREA 1.95 ACRES LOT 1: 1.80 ACRES STREET LOT A: 0.15 ACRES ZONING: EXISTING: M-1: LIGHT INDUSTRIAL DISTRICT PROPOSED: N/A MAXIMUM BUILDING HEIGHT: 40' MAXIMUM # OF STORIES: 3 STORIES SETBACKS: FRONT: 30' SIDE: 30' REAR: 30' NOTE: THE ERROR OF CLOSURE IS WITHIN THE CITY REQUIREMENTS FOUND IRON ROD OR PIPE WITH YELLOW CAPWYC 50263 PeldsDesign Services Architecture | Engineering | Surveying 2323 Dixon Street, Des Moines, Iowa 50316 | PO Box 4626, Des Moines, Iowa 50305 | Ph: 515 265 8196 I HEREBY CERTIFY THAT THIS LAND SURVEYING DOCUMENT WAS PREPARED AND THE RELATED WORK WAS PERFORMED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL LAND SURVEYOR UNDER THE LAWS OF THE STATE OF IOWA. ___________________________________________ VOLDEMARS LEO PELDS, P.L.S. IA. LIC. NO.18842 DATE MY LICENSE RENEWAL DATE IS DECEMBER 31, 2025 ADDITIONAL PAGES OR SHEETS COVERED BY THIS SEAL (NONE UNLESS INDICATED HERE):_______________________________ VOLDEMARS L. 18842 PELDS IOWA L I C E N S ED PROFE S S I O N A L SURVEYOR ENGINEER & D N A L PARCEL 20-79 AS SHOWN IN THE RETRACEMENT PLAT OF SURVEY FILED DECEMBER 18, 2020, IN BOOK 2020, PAGE 35993 OF THE DALLAS COUNTY RECORDER'S OFFICE. AND LOT 6 IN I-80 WEST INDUSTRIAL PARK PLAT 1, ON OFFICIAL PLAT, NOW INCLUDED IN AND FORMING A PART OF THE CITY OF WAUKEE, DALLAS COUNTY, IOWA. PUBLIC UTILITY EASEMENTPUE SANITARY SEWER EASEMENTSSE NOTE: STREET LOT A WILL BE DEDICATED TO THE CITY OF WAUKEE. SOUTHEASTERLYSE-LY SOUTHERLYS-LY NORTHEASTERLYNE-LY VICINITY MAP 1" = 1000' PROJECT AREA INTERST A T E P K W Y UT E A V E UT E A V E I-80 I-80 OWNER: JKR PROPERTIES LLC DALLAS COUNTY ZONING: C-2 HIGHWAY SERVICE AND AGRICULTURAL RELATED COMMERCIAL OWNER: MCCARTHY BROTHERS LLC CITY OF WAUKEE ZONING: M - 1 LIGHT INDUSTRIAL Curve Table (P) Curve #Arc Length Radius Delta Chord Length Chord Direction C2 167.17'368.00'26°01'41"165.74'N71° 53' 59"E C3 278.19'265.00'60°08'52"265.59'N88°57'34"E Curve Table (R) Curve #Arc Length Radius Delta Chord Length Chord Direction C5 68.71'18659.55'01°12'39"68.71'S0° 50' 38"E POINT OF COMMENCEMENTPOC POINT OF BEGINNINGPOB 555 INTERSTATE PARTNERS CONCEPT 4.1 - VIEW FROM NORTH 03.12.2025 PAINTED HARDIE PANEL STONE BRICK PEMB TRIM GUTTER AND DOWNSPOUT METAL PANEL METAL PANEL STEEL OVERHEAD DOOR Façade Material Calculations Area % of total Area % of total Area % of total Area % of total Area % of total Stone 1283.33 19.01%314.97 23.33%280.00 6.63%314.97 23.33%2193.27 16.04% Brick 457.78 6.78%460.00 34.08%0.00 0.00%460.00 34.08%1377.78 10.08% Glass 2008.89 29.76%0.00 0.00%0.00 0.00%0.00 0.00%2008.89 14.69% EIFS 1466.67 21.73%0.00 0.00%0.00 0.00%0.00 0.00%1466.67 10.73% Hardie Panel 1533.33 22.72%574.89 42.59%0.00 0.00%574.89 42.59%2683.11 19.62% Metal panel 0.00 0.00%0.00 0.00%3944.00 93.37%0.00 0.00%3944.00 28.84% Total façade area 6750.00 1349.86 4224.00 1349.86 13673.72 Primary materials 5283.33 78.27%1349.86 100.00%280.00 6.63%1349.86 100.00%8263.05 60.43% Secondary materials 1466.67 21.73%0.00 0.00%3944.00 93.37%0.00 0.00%5410.67 39.57% South Elevation East Elevation North Elevation West Elevation All Elevations 555 INTERSTATE PARTNERS CONCEPT 4.1 - VIEW FROM SOUTH 03.12.2025 PAINTED HARDIE PANEL EIFS STONE BRICK ALUMINUM STORE FRONT PEMB TRIM 555 INTERSTATE PARTNERS CONCEPT 4.1 - VIEW FROM WEST 03.12.2025 PAINTED HARDIE PANEL EIFS STONE BRICK ALUMINUM STORE FRONT PEMB TRIM BRICK 555 INTERSTATE PARTNERS TRASH ENCLOSURE 03.12.2025 WALL CAP BRICK ALL SIDES STEEL GATE 555 INTERSTATE PARTNERS TRASH ENCLOSURE 03.12.2025 WALL CAP BRICK ALL SIDES STEEL GATE