Loading...
HomeMy WebLinkAbout2025-10-06 I07A-C Kettlestone Central South Plat 4 Lots 1 and 2_Preliminary Plat, Final Plat, Site Plan AGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: October 6, 2025 AGENDA ITEM: Consideration of approval of resolutions approving a preliminary plat, final plat and site plan for Kettlestone Central South Plat 4 – Lots 1 & 2 / Kettlestone Central South Plat 4 FORMAT: Resolutions SYNOPSIS INCLUDING PRO & CON: The applicant is requesting approval of a preliminary plat/site plan and final plat for a commercial development, located south of SE Westown Parkway and east of Grand Prairie Parkway, containing 3.57-acres. The project includes a five-story mixed-use building on Lot 1. The building is proposed to be 95,191 square feet in area and 56-feet in height at the tallest point. The building will include 91 residential units, ranging in size from 606 square feet for a 1-bedroom unit to 1,122 square feet for a 2-bedroom unit. There will also be suites available ranging in size from 629 square feet to 742 square feet. The first floor of the building includes a bank that is 8,541 square feet in area. The bank also includes a drive-thru located on the south side of the building. A monument sign is shown at the north side of the site, along SE Westown Parkway. A trash enclosure is shown at the south side of the site, within the parking lot. The final plat shows the existing lot being divided into two lots. Lot 1 is 2.96- acres in area and is the lot that consists of the proposed five-story, mixed-use building. Lot 2 is 0.61-acres is intended for future development. The site plan shows a future single-story commercial building on Lot 2, which will require a separate site plan approval through Planning & Zoning Commission and City Council. Several accesses will be provided into the site. Two accesses will be provided directly into the site from the surrounding public streets – one from SE Westown Parkway and one from SE Glacier Trail. Two other accesses will be provided from the shared access drive located along the west side of the site. A ten-foot-wide trail exists along the west side of SE Glacier Trail at the east side of the site. A ten-foot-wide trail will be installed along the south side of SE Westown Parkway, adjacent to the site. Several pedestrian connections will be provided into the site from the public trails. Private sidewalks are shown throughout the development in order to provide internal pedestrian access across the site as well as provide access to adjacent lots. I7A-C A total of 190 parking spaces are required, they are providing 196 spaces. They are also providing 10 bicycle parking spaces in accordance with the Kettlestone Design Guidelines. Public utilities are provided to the site, but all utilities internal to the site will be private utilities to be privately owned and maintained. Storm water detention will be provided in the existing pond located at the south side of the overall development, just north of SE Tallgrass Lane. The pond will be privately owned and maintained. A minimum of 20% of the site is required to be open space, they are providing 24% for Lot 1. The future proposed open space for Lot 2 is 40%. The required amount of plantings are being provided. Parkland dedication requirements will be met with a fee in lieu of land dedication. The elevations of the buildings will be constructed of brick, fiber cement siding and panel, and glazing. The trash enclosure is proposed to be constructed of brick to match the building with metal gates. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning Commission reviewed the preliminary plat, final plat, and site plan request at their meeting on September 9, 2025, and recommended approval: Approval of a Preliminary Plat for Kettlestone Central South Plat 4 – Lots 1 & 2, Approval of a Final Plat for Kettlestone Central South Plat 4, and approval of a Site Plan for Kettlestone Central South Plat 4 – Lots 1 & 2 (1240 & 1280 SE Westown Parkway) Melissa DeBoer, Planning Coordinator, introduced the request for approval of a preliminary plat/site plan and final plat for a commercial development, as requested by Caliber Land Company, LLC, represented y Nikki Neal of Civil Design Advantage. The subject property is located within the Kettlestone Corridor and includes 3.57-acres. The property is currently going through the rezoning process to rezone proposed Lot 1 from K-RC (Kettlestone Retail Community District) to K-MU (Kettlestone Mixed Use District) / PD-1 (Planned Development Overlay). The final reading of the rezoning is planned for the September 15, 2025, City Council meeting agenda. Proposed Lot 2 will remain the current zoning of K-RC (Kettlestone Retail Community District). The project includes a five-story mixed-use building on Lot 1. The building is proposed to be 95,191 square feet in area and 56-feet in height at the tallest point. The building will include 91 residential units, ranging in size from 606 square feet for a 1-bedroom unit to 1,122 square feet for a 2-bedroom unit. There will also be suites available ranging in size from 629 square feet to 742 square feet. The first floor of the building includes a bank that is 8,541 square feet in area. The bank also includes a drivethru located on the south side of the building. A monument sign is shown at the north side of the site, along SE Westown Parkway. A trash enclosure is shown at the south side of the site, within the parking lot. The final plat shows the existing lot being divided into two lots. Lot 1 is 2.96-acres in area and is the lot that consists of the proposed five-story, mixed-use building. Lot 2 is 0.61-acres is intended for future development. The site plan shows a future single-story commercial building on Lot 2, which will require a separate site plan approval through Planning & Zoning Commission and City Council. Several accesses will be provided onto the site. Two accesses will be provided directly into the site from the surrounding public streets – one from SE Westown Parkway and one from SE Glacier Trail. Two other accesses will be provided from the shared access drive located along the west side of the site. A total of 190 parking spaces is required for this project, and a total of 196 spaces are provided. This also includes 8 accessible parking stalls. The site plan also shows 10 bicycle parking spaces being provided in accordance with the Kettlestone Design Guidelines. A ten-foot-wide trail exists along the west side of SE Glacier Trail at the east side of the site. A ten- foot-wide trail will be installed along the south side of SE Westown Parkway, adjacent to the site. Several pedestrian connections will be provided into the site from the public trails. Private sidewalks are shown throughout the development in order to provide internal pedestrian access across the site as well as provide access to adjacent lots. Public utilities are provided to the site, but all utilities internal to the site will be private utilities to be privately owned and maintained. Storm water detention will be provided in the existing pond located at the south side of the overall development, just north of SE Tallgrass Lane. The pond will be privately owned and maintained. A minimum of 20% of the project area is required to be open space. The total amount of open space proposed for Lot 1 is 24% and the future proposed open space for Lot 2 is 40%. Plantings are being provided throughout the site in compliance with the Landscape & Open Space Ordinance and the Kettlestone Design Guidelines. The elevations of the building are proposed to be constructed of brick, fiber cement siding and panel, and glazing. The trash enclosure is proposed to be constructed of brick to match the building with metal gates. Elevations of the proposed building and trash enclosure have been provided for review. A photometric plan for the site lighting has been submitted, and it complies with the requirements of the Site Plan Ordinance and the Kettlestone Design Guidelines. All proposed easements have been indicated on the final plat. Private utility easements are provided across the site. The subject property is located within the Kettlestone Corridor. The land use shown within the Kettlestone Master Plan for the subject property is office. The Kettlestone Master Plan is intended to act as a guide for land use while at the same time allowing for flexibility of land uses. The intent is that the land use designations can move based upon market demands. The proposed preliminary plat/site plan and final plat are in general conformance with the Zoning Ordinance, Subdivision Ordinance, Site Plan Ordinance, Kettlestone Master Plan, and Kettlestone Design Guidelines. Staff recommends approval subject to any remaining staff comments and review of the legal documents. Discussion as follows: (None) Motion by Commissioner Tuel for Approval of a Preliminary Plat for Kettlestone Central South Plat 4 – Lots 1 & 2, seconded by Commissioner Lohse. Ayes: Broderick, Beenken, Lohse, Tuel, and Bannister. Nays: None. Motion carried. Motion by Commissioner Lohse for Approval of a Final Plat for Kettlestone Central South Plat 4, seconded by Commissioner Broderick. Ayes: Broderick, Beenken, Lohse, Tuel, and Bannister. Nays: None. Motion carried. Motion by Commissioner Bannister for Approval of a Site Plan for Kettlestone Central South Plat 4 – Lots 1 & 2 (1240 & 1280 SE Westown Parkway), seconded by Commissioner Broderick. Ayes: Broderick, Beenken, Lohse, Tuel, and Bannister. Nays: None. Motion carried. RECOMMENDATION: Approve the resolutions. ATTACHMENTS: I. Proposed Resolutions II. Staff Report III. Preliminary Plat/Site Plan IV. Final Plat V. Building Elevations PREPARED BY: Melissa DeBoer, Planning Coordinator REVIEWED BY: PUBLIC NOTICE INFORMATION – NAME OF PUBLICATION: DATE OF PUBLICATION: THE CITY OF WAUKEE, IOWA RESOLUTION 2025- APPROVING THE PRELIMINARY PLAT FOR KETTLESTONE CENTRAL SOUTH PLAT 4 – LOTS 1 & 2 IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission reviewed and recommended approval of a Preliminary Plat for Kettlestone Central South Plat 4 – Lots 1 & 2 on September 9, 2025; AND, WHEREAS, the Preliminary Plat for Kettlestone Central South Plat 4 – Lots 1 & 2 is in general conformance with section §176 - Subdivision Regulations of the Waukee Municipal Code. NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this the 6th day of October, 2025 that the Preliminary Plat for Kettlestone Central South Plat 4 – Lots 1 & 2 be approved subject to remaining staff comments. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN R. Charles Bottenberg Chris Crone Rob Grove Anna Bergman Pierce Ben Sinclair THE CITY OF WAUKEE, IOWA RESOLUTION 2025- APPROVING THE FINAL PLAT FOR KETTLESTONE CENTRAL SOUTH PLAT 4 IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, CALIBER LAND COMPANY, LLC has requested final plat approval of Kettlestone Central South Plat 4 (the “Plat”); AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Plat on September 9, 2025, subject to remaining staff comments and review of the legal documents; AND, WHEREAS, the Final Plat for Kettlestone Central South Plat 4 and the documents relating thereto will comply with section §176 – Subdivision Regulations of the Waukee Municipal Code. NOW, THEREFORE, BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 6th day of October, 2025, that the Final Plat for Kettlestone Central South Plat 4 be and the same is hereby accepted and approved by the City Council of the City of Waukee. BE IT FURTHER RESOLVED that the City of Waukee does hereby accept the following easements and documents to be filed with the Plat: 1. Off-Site Private Storm Sewer Easement; 2. Private Storm Sewer Easement(s); 3. Private Water Main Easement(s); 4. Private Sanitary Sewer Easement(s); and 5. Public Parking and Access Easement(s) ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN R. Charles Bottenberg Chris Crone Rob Grove Anna Bergman Pierce Ben Sinclair THE CITY OF WAUKEE, IOWA RESOLUTION 2025- APPROVING THE SITE PLAN FOR KETTLESTONE CENTRAL SOUTH PLAT 4 – LOTS 1 & 2 IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Site Plan for Kettlestone Central South Plat 4 – Lots 1 & 2, subject to remaining staff comments on September 9, 2025; AND, WHEREAS, the Site Plan for Kettlestone Central South Plat 4 – Lots 1 & 2 is in general conformance with §160 – Site and Building Development Standards Ordinance of the Waukee Municipal Code; AND, WHEREAS, the Site Plan for Kettlestone Central South Plat 4 – Lots 1 & 2 is in general conformance with §161 – Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND, NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 6th day of October, 2025, that the Site Plan for Kettlestone Central South Plat 4 – Lots 1 & 2 is approved subject to remaining staff comments. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN R. Charles Bottenberg Chris Crone Rob Grove Anna Bergman Pierce Ben Sinclair PLANNING AND ZONING COMMISSION STAFF REPORT PROJECT: Kettlestone Central South Plat 4 – Lots 1 & 2 – Preliminary Plat / Site Plan and Kettlestone Central South Plat 4 – Final Plat PREPARED BY: Melissa DeBoer, AICP – Planning Coordinator REPORT DATE: September 4, 2025 MEETING DATE: September 9, 2025 GENERAL INFORMATION Owner/Applicant: Caliber Land Company, LLC Owner’s Representative: Nikki Neal, ASLA with Civil Design Advantage Request: The applicant is requesting approval of a preliminary plat/site plan and final plat for a commercial development. Location and Size: Property is located south of SE Westown Parkway and east of Grand Prairie Parkway, containing approximately 3.57 acres. Property Address: 1240 & 1280 SE Westown Parkway AREA MAP ABOVE: Aerial of subject property (outlined in BLUE) in relation to the surrounding area. September 4, 2025 2 of 3 LAND USES AND ZONING Location Existing Land Use Kettlestone Master Plan Current Zoning Property in Question Vacant - Undeveloped Office K-RC (Kettlestone Retail Community District) North Vacant - Undeveloped Office K-RR (Kettlestone Retail Regional District) South Vacant - Undeveloped Office K-MU (Kettlestone Mixed-Use) / PD-1 (Planned Development Overlay) East Commercial - Dancin with Roxie Office K-RC (Kettlestone Retail Community District) West Vacant - Undeveloped Office K-RC (Kettlestone Retail Community District) BACKGROUND The subject property is located within the Kettlestone Corridor and includes 3.57-acres. The property is currently going through the rezoning process to rezone proposed Lot 1 from K-RC (Kettlestone Retail Community District) to K-MU (Kettlestone Mixed Use District) / PD-1 (Planned Development Overlay). The final reading of the rezoning is planned for the September 15, 2025, City Council meeting agenda. Proposed Lot 2 will remain the current zoning of K-RC (Kettlestone Retail Community District). PROJECT DESCRIPTION The project includes a five-story mixed-use building on Lot 1. The building is proposed to be 95,191 square feet in area and 56-feet in height at the tallest point. The building will include 91 residential units, ranging in size from 606 square feet for a 1-bedroom unit to 1,122 square feet for a 2-bedroom unit. There will also be suites available ranging in size from 629 square feet to 742 square feet. The first floor of the building includes a bank that is 8,541 square feet in area. The bank also includes a drive- thru located on the south side of the building. A monument sign is shown at the north side of the site, along SE Westown Parkway. A trash enclosure is shown at the south side of the site, within the parking lot. The final plat shows the existing lot being divided into two lots. Lot 1 is 2.96-acres in area and is the lot that consists of the proposed five-story, mixed-use building. Lot 2 is 0.61-acres is intended for future development. The site plan shows a future single-story commercial building on Lot 2, which will require a separate site plan approval through Planning & Zoning Commission and City Council. ACCESS AND PARKING Several accesses will be provided into the site. Two accesses will be provided directly into the site from the surrounding public streets – one from SE Westown Parkway and one from SE Glacier Trail. Two other accesses will be provided from the shared access drive located along the west side of the site. A total of 190 parking spaces are required for this project and a total of 196 spaces are provided. This also includes 8 accessible parking stalls. The site plan also shows 10 bicycle parking spaces being provided in accordance with the Kettlestone Design Guidelines. September 4, 2025 3 of 3 SIDEWALKS/TRAILS A ten-foot-wide trail exists along the west side of SE Glacier Trail at the east side of the site. A ten-foot-wide trail will be installed along the south side of SE Westown Parkway, adjacent to the site. Several pedestrian connections will be provided into the site from the public trails. Private sidewalks are shown throughout the development in order to provide internal pedestrian access across the site as well as provide access to adjacent lots. UTILITIES Public utilities are provided to the site, but all utilities internal to the site will be private utilities to be privately owned and maintained. Storm water detention will be provided in the existing pond located at the south side of the overall development, just north of SE Tallgrass Lane. The pond will be privately owned and maintained. LANDSCAPING & OPEN SPACE A minimum of 20% of the project area is required to be open space. The total amount of open space proposed for Lot 1 is 24% and the future proposed open space for Lot 2 is 40%. Plantings are being provided throughout the site in compliance with the Landscape & Open Space Ordinance and the Kettlestone Design Guidelines. ELEVATIONS The elevations of the building are proposed to be constructed of brick, fiber cement siding and panel, and glazing. The trash enclosure is proposed to be constructed of brick to match the building with metal gates. Elevations of the proposed building and trash enclosure have been provided for review. LIGHTING PLAN A photometric plan for the site lighting has been submitted and it complies with the requirements of the Site Plan Ordinance and the Kettlestone Design Guidelines. EASEMENTS All proposed easements have been indicated on the final plat. Private utility easements are provided across the site. COMPREHENSIVE PLAN The subject property is located within the Kettlestone Corridor. The land use shown within the Kettlestone Master Plan for the subject property is office. The Kettlestone Master Plan is intended to act as a guide for land use while at the same time allowing for flexibility of land uses. The intent is that the land use designations can move based upon market demands. STAFF RECOMMENDATION The proposed preliminary plat/site plan and final plat are in general conformance with the Zoning Ordinance, Subdivision Ordinance, Site Plan Ordinance, Kettlestone Master Plan, and Kettlestone Design Guidelines. Staff recommends approval subject to any remaining staff comments and review of the legal documents. KETTLESTONE CENTRAL SOUTH PLAT 4 - LOTS 1 & 2 4121 NW URBANDALE DRIVE, URBANDALE, IA 50322 PH: (515) 369-4400 CIVIL DESIGN ADVANTAGE UTILITY WARNING DEVELOPMENT SUMMARY SUBMITTAL DATES ARCHITECT SURVEYOR OWNER/APPLICANT INDEX OF SHEETS GENERAL LEGEND ENGINEER LEGAL DESCRIPTION KETTLESTONE CENTRAL SOUTH PLAT 4 - LOTS 1 & 2 SITE PLAN/PRELIMINARY PLAT FOR: WAUKEE, IOWA l l l l l l www.iowaonecall.com 1-800-292-8989 ONE CALL IOWA ONE CALL Know what's before you dig. below.Call PRELIMIN A R Y NOT FOR C O N S T R U C T I O N PRELIMI N A R Y NOT FOR C O N S T R U C T I O N VICINITY MAP WAUKEE, IOWA PA R K W A Y PR A I R I E GR A N D SE W A C O P L A C E / 9 8 T H S T R E E T ASHWORTH ROA D INT E R S T A T E 8 0 SE WESTOWN PARKWAY SITE EXISTING/ PROPOSED USE PROJECT SITE ADDRESS DATE OF SURVEY BENCHMARKS BUILDINGS ZONING & BULK REGULATIONS – – – – – SE WESTOWN P A R K W A Y SE G L A C I E R T R A I L LOT 5 N0 0 ° 2 7 ' 1 6 " E 5 3 . 0 0 ' N0 1 ° 1 9 ' 2 8 " W 8 6 . 1 8 ' Δ=15°00'15" L=141.41' R=540.00' CH=141.01' CHB=N13°16'30"E Δ=92°49'51" L=40.51' R=25.00' CH=36.22' CHB=N25°38'18"W Δ=24°08'49" L=299.22' R=710.00' CH=297.01' CHB=N84°07'38"W S83°47'58"W 205 . 8 8 ' S11°54'40"E 82.92' Δ=12°21'56" L=64.75' R=300.00' CH=64.62' CHB=S05°43'42"E S0 0 ° 2 7 ' 1 6 " W 2 8 . 9 1 ' Δ=27°38'43" L=144.75' R=300.00' CH=143.35' CHB=S13°22'06"E S89°32'44"E 428.53' ZO N I N G : K- R C K E T T L E S T O N E R E T A I L CO M M U N I T Y D I S T R I C T ZONING: K-RC KETTLESTONE RETAIL COMMUNITY DISTRICT ZON I N G : RR K E T T L E S T O N E R E T A I L REG I O N A L D I S T R I C T ZONING : P D - 1 UNDERL Y I N G K - M U K E T T L E S T O N E M I X E D U S E D I S T R I C T TO P O G R A P H I C S U R V E Y & D E M O L I T I O N P L A N C1.1 WA U K E E , I O W A RE V I S I O N S DR A F T E D : EN G I N E E R : CI V I L D E S I G N A D V A N T A G E DA T E KE T T L E S T O N E C E N T R A L S O U T H P L A T 4 - L O T S 1 & 2 PH O N E : ( 5 1 5 ) 3 6 9 - 4 4 0 0 41 2 1 N W U R B A N D A L E D R I V E UR B A N D A L E , I A 5 0 3 2 2 2412.994 08/29/2025 DATE: SHEET NUMBER: DEMOLITION NOTES TRAFFIC CONTROL NOTES T T SE WESTOWN P A R K W A Y SE G L A C I E R T R A I L OV E R A L L P L A N C2.0 WA U K E E , I O W A RE V I S I O N S DR A F T E D : EN G I N E E R : CI V I L D E S I G N A D V A N T A G E DA T E KE T T L E S T O N E C E N T R A L S O U T H P L A T 4 - L O T S 1 & 2 PH O N E : ( 5 1 5 ) 3 6 9 - 4 4 0 0 41 2 1 N W U R B A N D A L E D R I V E UR B A N D A L E , I A 5 0 3 2 2 2412.994 08/29/2025 DATE: SHEET NUMBER: T SE WESTOWN P A R K W A Y SE G L A C I E R T R A I L LOT 1 PROPOSED BUILDING 5-STORY GFA=95,191 SF LOT 2 FUTURE BUILDING 1-STORY GFA=4,910 SF S0 0 ° 2 7 ' 1 6 " W 1 9 9 . 1 5 ' S89°32'44"E 125.63' DI M E N S I O N P L A N C2.1 WA U K E E , I O W A RE V I S I O N S DR A F T E D : EN G I N E E R : CI V I L D E S I G N A D V A N T A G E DA T E KE T T L E S T O N E C E N T R A L S O U T H P L A T 4 - L O T S 1 & 2 PH O N E : ( 5 1 5 ) 3 6 9 - 4 4 0 0 41 2 1 N W U R B A N D A L E D R I V E UR B A N D A L E , I A 5 0 3 2 2 2412.994 08/29/2025 DATE: SHEET NUMBER: GENERAL NOTES PAVEMENT THICKNESS FIRE SAFETY T F.F.E.=1046.50 F.F.E.=1049.50 F.F.E.=1046.50 F.F.E.=1049.50 F.F.E.=1053.83 F.F.E.=1046.50 SE WESTOWN P A R K W A Y SE G L A C I E R T R A I L GR A D I N G P L A N C3.1 WA U K E E , I O W A RE V I S I O N S DR A F T E D : EN G I N E E R : CI V I L D E S I G N A D V A N T A G E DA T E KE T T L E S T O N E C E N T R A L S O U T H P L A T 4 - L O T S 1 & 2 PH O N E : ( 5 1 5 ) 3 6 9 - 4 4 0 0 41 2 1 N W U R B A N D A L E D R I V E UR B A N D A L E , I A 5 0 3 2 2 2412.994 08/29/2025 DATE: SHEET NUMBER: GRADING NOTES DETAIL 'A' DETAIL 'B' DETAIL 'C' DETAIL 'D' DETAIL 'E' DETAIL 'F' S83°47'58"W 205 . 8 8 ' S11°54'40"E 82.92' F.F.E.=1049.50 F.F.E.=1046.50 GR A D I N G P L A N E N L A R G E M E N T S C3.2 WA U K E E , I O W A RE V I S I O N S DR A F T E D : EN G I N E E R : CI V I L D E S I G N A D V A N T A G E DA T E KE T T L E S T O N E C E N T R A L S O U T H P L A T 4 - L O T S 1 & 2 PH O N E : ( 5 1 5 ) 3 6 9 - 4 4 0 0 41 2 1 N W U R B A N D A L E D R I V E UR B A N D A L E , I A 5 0 3 2 2 2412.994 08/29/2025 DATE: SHEET NUMBER: DETAIL 'A'DETAIL 'B'DETAIL 'C' DETAIL 'D'DETAIL 'E'DETAIL 'F' SE WESTOWN P A R K W A Y T T l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l R l l lll l l l l l l l l l l l l l l DA #1 4.00 AC R l l l l SWPPP LEGEND STABILIZATION QUANTITIES ER O S I O N A N D S E D I M E N T C O N T R O L P L A N C4.1 NOTES: WA U K E E , I O W A RE V I S I O N S DR A F T E D : EN G I N E E R : CI V I L D E S I G N A D V A N T A G E DA T E KE T T L E S T O N E C E N T R A L S O U T H P L A T 4 - L O T S 1 & 2 PH O N E : ( 5 1 5 ) 3 6 9 - 4 4 0 0 41 2 1 N W U R B A N D A L E D R I V E UR B A N D A L E , I A 5 0 3 2 2 2412.994 08/29/2025 DATE: SHEET NUMBER: T SE WESTOWN P A R K W A Y SE G L A C I E R T R A I L 15 0 ' H Y D R A N T RA D I U S 15 0 ' H Y D R A N T 15 0 ' H Y D R A N T R A D I U S 15 0 ' H Y D R A N T R A D I U S 15 0 ' H Y D R A N T R A D I U S 15 0 ' H Y D R A N T RA D I U S 15 0 ' H Y D R A N T R A D I U S 15 0 ' H Y D R A N T RA D I U S 15 0 ' H Y D R A N T R A D I U S 15 0 ' H Y D R A N T RA D I U S 15 0 ' H Y D R A N T RA D I U S 15 0 ' H Y D R A N T RA D I U S 15 0 ' H Y D R A N T R A D I U S 15 0 ' H Y D R A N T RA D I U S 15 0 ' H Y D R A N T R A D I U S UT I L I T Y P L A N C5.1 WA U K E E , I O W A RE V I S I O N S DR A F T E D : EN G I N E E R : CI V I L D E S I G N A D V A N T A G E DA T E KE T T L E S T O N E C E N T R A L S O U T H P L A T 4 - L O T S 1 & 2 PH O N E : ( 5 1 5 ) 3 6 9 - 4 4 0 0 41 2 1 N W U R B A N D A L E D R I V E UR B A N D A L E , I A 5 0 3 2 2 2412.994 08/29/2025 DATE: SHEET NUMBER: UTILITY NOTES DE T A I L S C6.1 WA U K E E , I O W A RE V I S I O N S DR A F T E D : EN G I N E E R : CI V I L D E S I G N A D V A N T A G E DA T E KE T T L E S T O N E C E N T R A L S O U T H P L A T 4 - L O T S 1 & 2 PH O N E : ( 5 1 5 ) 3 6 9 - 4 4 0 0 41 2 1 N W U R B A N D A L E D R I V E UR B A N D A L E , I A 5 0 3 2 2 2412.994 08/29/2025 DATE: SHEET NUMBER: l l 2 INTEGRAL 6" STANDARD CURB 3 6" INTEGRAL CURB AND SIDEWALK 4 ACCESSIBLE PARKING SIGN 1 PCC PAVEMENT 7 GENERAL FEATURES OF AN ACESSIBLE SIDEWALK 5 CURB RAMPS - GENERAL SECTION 6 SUDAS TYPE A DRIVEWAY 9 CITY OF WAUKEE HYDRANT (DWG NO. 34, REV. 2)8 ROOF DRAIN CONNECTION DE T A I L S C6.2 WA U K E E , I O W A RE V I S I O N S DR A F T E D : EN G I N E E R : CI V I L D E S I G N A D V A N T A G E DA T E KE T T L E S T O N E C E N T R A L S O U T H P L A T 4 - L O T S 1 & 2 PH O N E : ( 5 1 5 ) 3 6 9 - 4 4 0 0 41 2 1 N W U R B A N D A L E D R I V E UR B A N D A L E , I A 5 0 3 2 2 2412.994 08/29/2025 DATE: SHEET NUMBER: 48 60 72 84 96 24 36 42 48 60 18 24 30 36 42 3Manhole Diameter (inches) Maximum Pipe Diameter (inches) for 2 Pipes at 180 Separation at 90 Separation PLAN 14" x 8" Beams (full length and width of structure) BEAM DETAIL SECTION A-A SECTION B-B 8" (see beam detail) Diagonal Bars (typ.)BB B B 1 SW-512 CIRCULAR AREA INTAKE3SW-516 LARGE WELL DOUBLE GRATE INTAKE WITH MANHOLE 2 SW-502 - CIRCULAR SINGLE GRATE INTAKE CODE QTY COMMON NAME BOTANICAL NAME CONDITION AND SIZE OVERSTORY TREES ® ® EVERGREEN TREES ORNAMENTAL TREES SHRUBS ® ® GRASSES PERENNIALS PLANT SCHEDULE LOT 1 CODE QTY COMMON NAME BOTANICAL NAME CONDITION AND SIZE OVERSTORY TREES ® ® EVERGREEN TREES ORNAMENTAL TREES SHRUBS ® PLANT SCHEDULE LOT 2 WA U K E E , I O W A RE V I S I O N S DR A F T E D : EN G I N E E R : CI V I L D E S I G N A D V A N T A G E DA T E KE T T L E S T O N E C E N T R A L S O U T H P L A T 4 - L O T S 1 & 2 PH O N E : ( 5 1 5 ) 3 6 9 - 4 4 0 0 41 2 1 N W U R B A N D A L E D R I V E UR B A N D A L E , I A 5 0 3 2 2 2412.994 08/29/2025 DATE: SHEET NUMBER: LANDSCAPE NOTES LOT 1 LANDSCAPE REQUIREMENTS LOT 2 LANDSCAPE REQUIREMENTS LA N D S C A P E N O T E S L1.1 T T LOT 1 LOT 2 WA U K E E , I O W A RE V I S I O N S DR A F T E D : EN G I N E E R : CI V I L D E S I G N A D V A N T A G E DA T E KE T T L E S T O N E C E N T R A L S O U T H P L A T 4 - L O T S 1 & 2 PH O N E : ( 5 1 5 ) 3 6 9 - 4 4 0 0 41 2 1 N W U R B A N D A L E D R I V E UR B A N D A L E , I A 5 0 3 2 2 2412.994 08/29/2025 DATE: SHEET NUMBER: LA N D S C A P E P L A N L1.2 Δ= 1 5 ° 0 0 ' 1 5 " L= 1 4 1 . 4 1 ' R= 5 4 0 . 0 0 ' CH = 1 4 1 . 0 1 ' CH B = S 1 3 ° 1 6 ' 3 0 " W (M & R ) Δ=92°49'51" L=40.51' R=25.00' CH=36.22' CHB=S25°38'18"E (M&R) Δ=24°08'49" L=299.22' R=710.00' CH=297.01' CHB=S84°07'38"E (M&R) N83°47'58"E 205.88'(M&R) N89°32'44"W 428.53'(M&R) S0 0 ° 2 7 ' 1 6 " W 53 . 0 0 ' ( M & R ) S0 1 ° 1 9 ' 2 8 " E 86 . 1 8 ' ( M & R ) LOT 2 LOT 1 N11°54'40"W 82.92'(M&R) Δ=12°21'56" L=64.75' R=300.00' CH=64.62' CHB=N05°43'42"W (M&R) N00°27'16"E 28.91'(M&R) Δ=27°38'43" L=144.75' R=300.00' CH=143.35' CHB=N13°22'06"W (M&R) KETTLESTONE CENTRAL SOUTH PLAT 4 FINAL PLAT CI V I L D E S I G N A D V A N T A G E 2412.994 KE T T L E S T O N E C E N T R A L S O U T H P L A T 4 EN G I N E E R : TE C H : RE V I S I O N S DA T E WA U K E E , I O W A 1 FI R S T S U B M I T T A L 06 / 2 4 / 2 5 PH O N E : ( 5 1 5 ) 3 6 9 - 4 4 0 0 41 2 1 N W U R B A N D A L E D R I V E UR B A N D A L E , I A 5 0 3 2 2 RE V I E W : SE C O N D S U B M I T T A L 07 / 0 8 / 2 5 TH I R D S U B M I T T A L 08 / 1 9 / 2 5 1 FI N A L P L A T INDEX LEGEND PRELIMIN A R Y NOT FOR C O N S T R U C T I O N VICINITY MAP WAUKEE, IOWA PA R K W A Y PR A I R I E GR A N D SE W A C O P L A C E / 9 8 T H S T R E E T ASHWORTH ROA D SE WESTOWN PARKWAY SITE ENGINEER / SURVEYOR SE WESTOWN P A R K W A Y LEGEND OWNER / DEVELOPER DATE OF SURVEY PLAT DESCRIPTION NOTES – – – – – ZONING AND BULK REGULATIONS SE G L A C I E R T R A I L DN 8541 SF BANK COMMERCIAL (BANK) 2968 SF AMENITY RESIDENTIAL ENTRY ST A I R 803 SF UNIT 101 1 BED + DEN 907 SF UNIT 102 2 BED 736 SF UNIT 107 SUITE (1 BED) 629 SF UNIT 106 SUITE (1 BED) 629 SF UNIT 105 SUITE (1 BED) 629 SF UNIT 103 SUITE (1 BED) 606 SF UNIT 104 1 BED . FLOOR LINE ABOVE . . . STAIR PACK. 150 SF STOR. MECH. 3' - 0" 0' - 0" 3' - 0" MAIL 0' - 0" 133 SF STOR. F.S. 12 ' - 0 " 13 8 ' - 6 " 62'-7" 62 ' - 0 " 75 ' - 6 " 2"19'-0"8'-8"10'-2"2"18'-10"2"18'-10"2"18'-10"2"18'-10"2"24'-0" 6' - 4 " 24 ' - 0 " 6' - 0 " 33 ' - 6 " 6' - 0 " 6' - 0 " 2' - 0 " 2' - 0 " 85'-6" 185'-2" 13'-5"5'-5"13'-5"5'-5"13'-5"5'-5" 6' - 2 " 11 ' - 1 " 6' - 9 " 6' - 0 " 12 0 ' - 2 " 6'-4"12'-6"6'-6"6'-8"12'-10"9'-11"8'-5" 24'-4"2"25'-4"2"11'-8"2"37'-10" 6'-0" 99'-8" 2'-0"4'-0" 3'-6"11'-11"8'-7" 3' - 1 0 " 11 ' - 2 " 10 ' - 6 " 8' - 0 " 2' - 6 " 3' - 6 " 2' - 6 " 3' - 6 " 7'-6"11'-0"6" 47'-0" 5'-0"6'-6"4'-0"6'-6"12'-2"6'-6"6'-6" 19 3 ' - 8 " 74 ' - 2 " 2" 38 ' - 0 " 38 ' - 0 " 14 ' - 4 " 29 ' - 0 " 3' - 7 " 7' - 6 " 8' - 0 " 8' - 0 " 7' - 6 " 3' - 7 " 5" 9' - 0 " 11 ' - 0 " 8' - 0 " 9' - 7 " 3' - 8 " 5' - 0 " 5' - 8 " 3' - 0 " 7' - 0 " 7' - 0 " 7' - 0 " 5' - 0 " 9' - 7 " 8' - 0 " 8' - 4 " 4' - 0 " 44 ' - 5 " 4'-0"2'-0"16'-0"63'-6" 5'-0"7'-6"3'-6" 43 ' - 2 " 70 ' - 8 " 12 ' - 4 " 14 ' - 1 1 " 8' - 0 " 4' - 6 " 5' - 0 " 10 ' - 1 1 1 / 2 " 5' - 0 " 4' - 6 1 / 2 " 8' - 0 " 9' - 9 " 6'-0 1/2"18'-0" 3 1/2" 4'-2"5'-0"2'-6" 13'-5"5'-5" 2'-0"2'-0" 16'-0" 10"7'-10"1'-6" 2'-0"2'-0" 3611 NE Otterview Cir #42 Ankeny, IA 50021 www.jcorpdesignbuild.com CONTENTS: SHEET NO: PROJECT NO: PR O J E C T : REVISIONS: A101 24-019 Ke t t l e s t o n e C e n t r a l M i x e d U s e 08 / 05 / 2025 1st Floor PlanNORTHSCALE:3/32" = 1'-0"1 1ST FLOOR UNIT SCHEDULE TYPE QTY. AREA 1 BED 13 606 SF 1 BED + DEN 1 803 SF 2 BED 26 903 SF ... 1122 SF SUITE (1 BED) 51 629 SF ... 742 SF Grand total: 91 917 SF UNIT 221 2 BED 903 SF UNIT 220 2 BED 1122 SF UNIT 212 2 BED 917 SF UNIT 201 2 BED 907 SF UNIT 202 2 BED 908 SF UNIT 218 2 BED 629 SF UNIT 219 SUITE (1 BED) 629 SF UNIT 217 SUITE (1 BED) 742 SF UNIT 213 SUITE (1 BED) 705 SF UNIT 211 SUITE (1 BED) 629 SF UNIT 210 SUITE (1 BED) 742 SF UNIT 209 SUITE (1 BED) 742 SF UNIT 207 SUITE (1 BED) 629 SF UNIT 205 SUITE (1 BED) 629 SF UNIT 204 SUITE (1 BED) 629 SF UNIT 203 SUITE (1 BED) 606 SF UNIT 206 1 BED 606 SF UNIT 208 1 BED 606 SF UNIT 214 1 BED 908 SF UNIT 216 2 BED STAIR ST A I R OPEN TO BELOW 127 SF STOR. 77 SF IT 742 SF UNIT 215 SUITE (1 BED) 19 5 ' - 8 " 75 ' - 6 " 28'-0"2"18'-10"2"18'-10"2"18'-10"2"18'-10"2"18'-10"2"18'-10"2"18'-10"2"24'-0" 24 ' - 0 " 2" 18 ' - 1 0 " 2" 12 ' - 0 " 2" 18 ' - 1 0 " 2" 37 ' - 1 0 " 2" 18 ' - 1 0 " 2" 18 ' - 1 0 " 2" 43 ' - 4 " 2' - 0 " 4'-0"2'-0"55'-4"2"24'-0" 2" 6' - 2 " 24 ' - 0 " 2" 39 ' - 4 " 6' - 0 " 6' - 0 " 2' - 0 " 2' - 0 " 85'-6" 185'-2" 3' - 6 " 11 ' - 1 1 " 8' - 7 " 12 ' - 6 " 6' - 4 " 3' - 4 " 8' - 8 " 3' - 7 " 7' - 6 " 8' - 0 " 8' - 0 " 7' - 6 " 3' - 7 " 13 ' - 5 " 5' - 5 " 5' - 0 " 7' - 0 " 7' - 0 " 7' - 0 " 3' - 0 " 8' - 2 " 6' - 2 " 5'-0"6'-6"4'-0"6'-6"6'-0"6'-0"6'-6"4'-0"2'-6" 8'-0"10'-2"15'-0"6'-2"6'-2"11'-1"6'-9" 11'-5"7'-7"13'-5"5'-5"13'-5"5'-5"13'-5"5'-5"13'-5"5'-5"3'-6"20'-6" 2' - 6 " 3' - 6 " 2' - 6 " 3' - 6 " 5'-0"7'-6"3'-6" 8' - 5 " 9' - 1 1 " 12 ' - 1 0 " 6' - 8 " 7' - 1 1 " 11 ' - 0 " 11 ' - 0 " 7' - 1 1 " 7' - 1 1 " 11 ' - 0 " 11 ' - 0 " 7' - 1 1 " 6' - 2 " 11 ' - 1 " 6' - 9 " 9' - 8 " 11 ' - 6 " 10 ' - 2 " 8' - 0 " 6' - 8 " 5' - 8 " 6' - 1 0 " 6' - 0 " 6' - 0 " 12 0 ' - 2 " 5'-4"12'-6"6'-6"6'-4"12'-6"6'-6"6'-10"12'-10"9'-11"8'-5"6'-8"5'-0" 37 ' - 1 0 " 2" 37 ' - 1 0 " 2" 37 ' - 1 0 " 2" 12 ' - 2 " 24'-4"2"25'-4"2"11'-8"2"37'-10" 6'-0" 99'-8" 2'-0" 5'-0" 2'-6"2'-6" 2' - 6 " 6' - 0 " 8'-8" 13 ' - 5 " 5' - 5 " 13 ' - 5 " 5' - 5 " 13'-5"5'-5" 2'-0"2'-0" 3611 NE Otterview Cir #42 Ankeny, IA 50021 www.jcorpdesignbuild.com KEY PLAN CONTENTS: SHEET NO: PROJECT NO: PR O J E C T : REVISIONS: A102 24-019 Ke t t l e s t o n e C e n t r a l M i x e d U s e 08 / 05 / 2025 2nd Floor PlanNORTHSCALE:3/32" = 1'-0"1 2ND FLOOR UNIT SCHEDULE TYPE QTY. AREA 1 BED 13 606 SF 1 BED + DEN 1 803 SF 2 BED 26 903 SF ... 1122 SF SUITE (1 BED) 51 629 SF ... 742 SF Grand total: 91 1103 SF UNIT 312 2 BED 917 SF UNIT 301 2 BED 907 SF UNIT 302 2 BED 629 SF UNIT 319 SUITE (1 BED) 742 SF UNIT 317 SUITE (1 BED) 629 SF UNIT 316 SUITE (1 BED) 742 SF UNIT 315 SUITE (1 BED) 742 SF UNIT 313 SUITE (1 BED) 692 SF UNIT 311 SUITE (1 BED) 742 SF UNIT 309 SUITE (1 BED) 742 SF UNIT 307 SUITE (1 BED) 629 SF UNIT 305 SUITE (1 BED) 629 SF UNIT 304 SUITE (1 BED) 629 SF UNIT 303 SUITE (1 BED) 606 SF UNIT 306 1 BED 606 SF UNIT 308 1 BED 629 SF UNIT 310 SUITE (1 BED) 917 SF UNIT 323 2 BED 907 SF UNIT 322 2 BED 908 SF UNIT 320 2 BED 629 SF UNIT 321 SUITE (1 BED) 606 SF UNIT 314 1 BED 908 SF UNIT 318 2 BED STAIR ST A I R 19 5 ' - 8 " 75 ' - 6 " 28'-0"2"18'-10"2"18'-10"2"18'-10"2"18'-10"2"18'-10"2"18'-10"2"18'-10"2"24'-0" 24 ' - 0 " 2" 18 ' - 1 0 " 2" 12 ' - 0 " 2" 18 ' - 1 0 " 2" 18 ' - 1 0 " 2" 18 ' - 1 0 " 2"0" 18 ' - 1 0 " 2" 18 ' - 1 0 " 2" 43 ' - 4 " 2' - 0 " 4'-0"2'-0"55'-4"2"24'-0" 2" 6' - 2 " 24 ' - 0 " 2" 39 ' - 4 " 6' - 0 " 6' - 0 " 2' - 0 " 2' - 0 " 85'-6" 185'-2" 3' - 6 " 20 ' - 6 " 13 ' - 5 " 5' - 5 " 5' - 0 " 7' - 0 " 7' - 0 " 7' - 0 " 3' - 0 " 8' - 2 " 6' - 2 " 5'-0"6'-6"4'-0"6'-6"6'-0"6'-2"6'-6"4'-0"2'-6" 8'-0"25'-2"6'-2"6'-2"11'-1"6'-9" 11'-5"7'-7"13'-5"5'-5"13'-5"5'-5"13'-5"5'-5"13'-5"5'-5" 8' - 5 " 9' - 1 1 " 12 ' - 1 0 " 6' - 8 " 7' - 1 1 " 11 ' - 0 " 11 ' - 0 " 7' - 1 1 " 7' - 1 1 " 11 ' - 0 " 11 ' - 0 " 7' - 1 1 " 6' - 2 " 11 ' - 1 " 6' - 9 " 4' - 2 " 17 ' - 0 " 10 ' - 2 " 8' - 0 " 6' - 0 " 12 0 ' - 2 " 5'-4"12'-6"6'-6"6'-4"12'-6"6'-6"6'-10"12'-10"9'-11"8'-5"6'-8"5'-0" 37 ' - 1 0 " 2" 37 ' - 1 0 " 2" 37 ' - 1 0 " 2" 12 ' - 2 " 24'-4"2"25'-4"2"11'-8"2"37'-10" 6'-0" 99'-8" 3'-6"20'-6" 2' - 6 " 3' - 6 " 2' - 6 " 3' - 6 " 12 ' - 5 3 / 4 " 6' - 4 1 / 4 " 8' - 8 " 3' - 4 " 13 ' - 5 " 5' - 5 " 2' - 6 " 6' - 0 " 8'-8" 6' - 8 " 5' - 8 " 6' - 1 0 " 6' - 0 " 5'-0" 2'-6"2'-6" 3'-6" 3'-6"2'-6" 13 ' - 5 " 5' - 5 " 13 ' - 7 " 5' - 5 " 13 ' - 5 " 5' - 5 " 13'-5"5'-5" 3611 NE Otterview Cir #42 Ankeny, IA 50021 www.jcorpdesignbuild.com KEY PLAN CONTENTS: SHEET NO: PROJECT NO: PR O J E C T : REVISIONS: A103 24-019 Ke t t l e s t o n e C e n t r a l M i x e d U s e 08 / 05 / 2025 3rd-4th Floor PlansNORTHSCALE:3/32" = 1'-0"1 3RD - 4TH FLOORS UNIT SCHEDULE TYPE QTY. AREA 1 BED 13 606 SF 1 BED + DEN 1 803 SF 2 BED 26 903 SF ... 1122 SF SUITE (1 BED) 51 629 SF ... 742 SF Grand total: 91 629 SF UNIT 517 SUITE (1 BED) 629 SF UNIT 515 SUITE (1 BED) 629 SF UNIT 513 SUITE (1 BED) 629 SF UNIT 511 SUITE (1 BED) 742 SF UNIT 510 SUITE (1 BED) 691 SF UNIT 508 SUITE (1 BED) 629 SF UNIT 507 SUITE (1 BED) 742 SF UNIT 506 SUITE (1 BED) 629 SF UNIT 505 SUITE (1 BED) 629 SF UNIT 503 SUITE (1 BED) 606 SF UNIT 502 1 BED 606 SF UNIT 504 1 BED 908 SF UNIT 516 2 BED 606 SF UNIT 512 1 BED 908 SF UNIT 514 2 BED 1103 SF UNIT 509 2 BED 1051 SF UNIT 501 2 BED ROOF BELOW ROOF BELOW STAIR ST A I R 15 2 ' - 6 " 36 ' - 0 " 27 ' - 6 " 6' - 0 " 2' - 0 " 2' - 0 " 85'-6" 161'-2" 5' - 0 " 7' - 0 " 7' - 0 " 5' - 1 1 " 1' - 1 " 3' - 0 " 14 ' - 4 " 5'-0"6'-6"4'-0"6'-6"6'-0"6'-0"6'-6"4'-0"2'-6"9'-5"9'-5"13'-5"5'-5"11'-5"7'-5" 7' - 1 1 " 11 ' - 0 " 11 ' - 0 " 7' - 1 1 " 7' - 1 1 " 11 ' - 0 " 11 ' - 0 " 7' - 1 1 " 6' - 8 " 5' - 8 " 6' - 1 0 " 6' - 0 " 6' - 0 " 82 ' - 2 " 5'-4"12'-6"6'-6"6'-4"12'-6"6'-6"6'-8"5'-0" 37 ' - 1 0 " 2" 37 ' - 1 0 " 2" 12 ' - 2 " 24'-4"2"25'-4"2"11'-8"14'-0" 6'-0" 75'-8" 2' - 6 " 6' - 0 " 8'-8" 2'-6"2'-6" 28'-0"2"18'-10"2"18'-10"2"18'-10"2"18'-10"2"18'-10"2"38'-0" 13'-5"5'-5"30'-5"7'-7" 3' - 6 " 2' - 6 " 6' - 0 " 2' - 6 " 3' - 6 " 75 ' - 6 " 5' - 9 " 16 ' - 0 " 5' - 9 " 3' - 0 " 33 ' - 0 " 4'-0"57'-6"24'-0" 36'-6"3'-0"14'-6"9'-6" 12 ' - 0 " 2" 18 ' - 1 0 " 2" 18 ' - 1 0 " 2" 18 ' - 1 0 " 2" 18 ' - 1 0 " 2" 18 ' - 1 0 " 2" 14 ' - 4 " 29 ' - 0 " 2' - 0 " 13 ' - 5 " 5' - 5 " 13 ' - 5 " 5' - 5 " 3' - 2 3 / 4 " 8' - 9 1 / 4 " 11 ' - 5 " 7' - 5 " 11 ' - 5 " 7' - 5 " 3'-6"2'-6" 3'-6"2'-6" 11 ' - 5 " 7' - 5 " 3611 NE Otterview Cir #42 Ankeny, IA 50021 www.jcorpdesignbuild.com KEY PLAN CONTENTS: SHEET NO: PROJECT NO: PR O J E C T : REVISIONS: A104 24-019 Ke t t l e s t o n e C e n t r a l M i x e d U s e 08 / 05 / 2025 5th Floor PlanNORTHSCALE:3/32" = 1'-0"1 5TH FLOOR UNIT SCHEDULE TYPE QTY. AREA 1 BED 13 606 SF 1 BED + DEN 1 803 SF 2 BED 26 903 SF ... 1122 SF SUITE (1 BED) 51 629 SF ... 742 SF Grand total: 91 1/4" / 12" SCUPPERS/DOWNSPOUTS @ COURTYARD SIDE (TYP.) 1/ 4 " / 1 2 " ROOF TERRACES BELOW ROOF TERRACE BELOW ROOF TERRACE BELOW ROOF TERRACE BELOW 1/4" / 12" 1/ 4 " / 1 2 " 1/ 4 " / 1 2 " EPDM ROOFING (TYP.) 1/ 4 " / 1 2 " 1/ 4 " / 1 2 " PARAPET MECHANICAL SCREENING PARAPET MECHANICAL SCREENING HIGH ROOF MECHANICAL SCREENING HIGH ROOF MECHANICAL SCREENING 1/4" / 12" 1/4" / 12" 1/ 4 " / 1 2 " 1/ 4 " / 1 2 " 1/4" / 12" 1/ 4 " / 1 2 " 1/ 4 " / 1 2 " 1/4" / 12" 4'-0" 4'-0" 4'-0" 2'-0" 2' - 0 " 3' - 6 1 / 2 " 4' - 0 " 4' - 0 " 2' - 0 " 2'-0" 4' - 0 " 3611 NE Otterview Cir #42 Ankeny, IA 50021 www.jcorpdesignbuild.com KEY PLAN CONTENTS: SHEET NO: PROJECT NO: PR O J E C T : REVISIONS: A105 24-019 Ke t t l e s t o n e C e n t r a l M i x e d U s e 08 / 05 / 2025 Roof Plan SCALE:3/32" = 1'-0"1 ROOF PLAN 1ST FLOOR 0' -0" 2ND FLOOR 13' -11 7/8" 3RD FLOOR 24' -11 3/4" TRUSS BRG. 56' -0 5/8" 1ST FLOOR T.O.W. 12' -1 1/8" 2ND FLR T.O.W. 23' -1" 4TH FLOOR 35' -11 5/8" 3RD FLR T.O.W. 34' -0 7/8" 5TH FLOOR 46' -11 1/2" 4TH FLR T.O.W. 45' -0 3/4" 1ST FLOOR -RES. 3' -0" B1 B1 B1S1 S1 S1 B1 B1 S1S1 S2 S2 S2 S2 S2 S2 S1 S1S1 B1 B1 TRUSS BRG. -HIGH 59' -0 5/8" S1 S1S1 S1 S1 S1 S1 S1S1S1 A/C CONDENSING UNITS (BEYOND PARAPET), TYP. ROOF LINE BEYOND UP/DOWN LIGHTING TYP. UPLIGHT SCREENED BY EAVES ABOVE 1ST FLOOR 0' -0" 2ND FLOOR 13' -11 7/8" 3RD FLOOR 24' -11 3/4" TRUSS BRG. 56' -0 5/8" 1ST FLOOR T.O.W. 12' -1 1/8" 2ND FLR T.O.W. 23' -1" 4TH FLOOR 35' -11 5/8" 3RD FLR T.O.W. 34' -0 7/8" 5TH FLOOR 46' -11 1/2" 4TH FLR T.O.W. 45' -0 3/4" 1ST FLOOR -RES. 3' -0" B1 B1 B1 B1 B1 B1 B1 B1 S1 S1 S1 S1 TRUSS BRG. -HIGH 59' -0 5/8" S1S1 B1 S1 S1 S1S1S1S1S1S1S1 UP/DOWN LIGHTING TYP. UPLIGHT SCREENED BY EAVES ABOVE 1ST FLOOR 0' -0" 2ND FLOOR 13' -11 7/8" 3RD FLOOR 24' -11 3/4" TRUSS BRG. 56' -0 5/8" 1ST FLOOR T.O.W. 12' -1 1/8" 2ND FLR T.O.W. 23' -1" 4TH FLOOR 35' -11 5/8" 3RD FLR T.O.W. 34' -0 7/8" 5TH FLOOR 46' -11 1/2" 4TH FLR T.O.W. 45' -0 3/4" 1ST FLOOR -RES. 3' -0" B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 S1 S1S1 S1 S1 TRUSS BRG. -HIGH 59' -0 5/8" S1S1S1 S1 S1S1 S1 S1 S1 S1S1 S1 S1 UP/DOWN LIGHTING TYP. UPLIGHT SCREENED BY EAVES ABOVE 2ND FLOOR 13' -11 7/8" 3RD FLOOR 24' -11 3/4" TRUSS BRG. 56' -0 5/8" 1ST FLOOR T.O.W. 12' -1 1/8" 2ND FLR T.O.W. 23' -1" 4TH FLOOR 35' -11 5/8" 3RD FLR T.O.W. 34' -0 7/8" 5TH FLOOR 46' -11 1/2" 4TH FLR T.O.W. 45' -0 3/4" 1ST FLOOR -RES. 3' -0" S2S2S2S2 B1 S2 S2 S2 B1 B1 B1 B1 B1 S1 S1 S1 S1 S1 TRUSS BRG. -HIGH 59' -0 5/8" S1 S1 S1 S1 S1S1 S1S1S1S1 S1 S1 S1 B1 B1 A/C CONDENSING UNITS (BEYOND PARAPET), TYP. ROOF LINE BEYOND UP/DOWN LIGHTING TYP. UPLIGHT SCREENED BY EAVES ABOVE SCALE:1/16" = 1'-0"4 SOUTH ELEVATION SCALE:1/16" = 1'-0"1 NORTH ELEVATION MATERIAL SCHEDULE Mark Description Area Percentage B1 Modular Brick - Light 13323 SF 38.2% S1 Fiber Cement Panel Siding - Dark 16901 SF 48.4% S2 Fiber Cement Lap Siding - Light 4668 SF 13.4% 3611 NE Otterview Cir #42 Ankeny, IA 50021 www.jcorpdesignbuild.com KEY PLAN CONTENTS: SHEET NO: PROJECT NO: PR O J E C T : REVISIONS: A201 24-019 Ke t t l e s t o n e C e n t r a l M i x e d U s e 08 / 05 / 2025 Concept Elevations SCALE:1/16" = 1'-0"2 WEST ELEVATION SCALE:1/16" = 1'-0"3 EAST ELEVATION 4,088 SF GLAZING 11,033 SF TOTAL 37% GLAZING 958 SF GLAZING (1ST FLOOR) 2,354 SF TOTAL (1ST FLOOR) 40.7% GLAZING 4,169 SF GLAZING 11,684 SF TOTAL 35.7% GLAZING 2,778 SF GLAZING 10,724 SF TOTAL 25.9% GLAZING 2,688 SF GLAZING 10,875 SF TOTAL 24.7% GLAZING 1,058 SF GLAZING (1ST FLOOR) 2,262 SF TOTAL (1ST FLOOR) 46.8% GLAZING (1ST FLOOR) BRICK -MODULAR -LIGHT FIBER CEMENT LAP SIDING -LIGHT FIBER CEMENT PANEL SIDING -DARK 3611 NE Otterview Cir #42 Ankeny, IA 50021 www.jcorpdesignbuild.com KEY PLAN CONTENTS: SHEET NO: PROJECT NO: PR O J E C T : REVISIONS: A106 24-019 Ke t t l e s t o n e C e n t r a l M i x e d U s e 08 / 05 / 2025 3d Views SCALE:1 VIEW FROM SW SCALE:2 VIEW FROM NW SCALE:3 VIEW FROM WEST