Loading...
HomeMy WebLinkAbout2026-03-02 I08A-C Caliber Kettlestone Plat 1_Preliminary Plat, Final Plat, Site Plan AGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: March 2, 2026 AGENDA ITEM: Consideration of approval of resolution approving a preliminary plat/site plan and final plat for Caliber Kettlestone Plat 1 (915 & 845 SE Esker Ridge Drive) FORMAT: Resolution SYNOPSIS INCLUDING PRO & CON: The applicant is requesting approval of a preliminary plat/site plan and final plat for a multi-family residential development. The property is located north of SE Esker Ridge Drive and east of SE Parkview Crossing Drive, containing 2.81-acres. The project includes the construction of two apartment buildings. One building includes 42 units and is just under 34,000 square feet in area and one building includes 66 units and is just under 54,000 square feet in area. Both buildings are three stories and around 40-ft in height. The total proposed density is approximately 38 dwelling units per acre. Per the planned development, the maximum density allowed is 42 dwelling units per acre. The proposed number of dwelling units meets the requirements of the planned development. The site plan also includes a trash enclosure located along the north side of the site, between the two buildings. The final plat includes two lots. Lot 1 is 1.14 acres in area and Lot 2 is 1.68 acres in area. Each lot contains one apartment building. The final plat includes several easements for utilities where necessary and ingress/egress easements to provide access across the lots. Three accesses will be provided into the development. One will be provided from the private drive along the north, one will be provided from SE Encompass Drive, and one access will be provided from SE Esker Ridge Drive along the south. A 10-foot-wide trail will be provided along the south side of the site, adjacent to SE Esker Ridge Drive. A 10-foot-wide trail exists along the west side of the site, adjacent to SE Parkview Crossing Drive. Existing sidewalks have been provided along the other sides of the property adjacent to the surrounding streets. Several pedestrian connections are provided into the site from the adjacent public trails and sidewalks. Several sidewalks are provided throughout the property to provide access around the buildings and parking areas. They are providing the required amount of parking, open space and landscaping. I8A-C Public utilities are provided to the site. Storm water detention is provided with an underground detention facility. The elevations of the buildings are proposed to be constructed of brick, fiber cement lap siding, and glazing. The trash enclosure is proposed to be constructed of brick to match the building with metal gates. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning Commission reviewed the preliminary plat/site plan and final plat request at their meeting on February 10, 2026, and recommended approval: Approval of a Preliminary Plat for Caliber Kettlestone Plat 1, Approval of a Final Plat for Caliber Kettlestone Plat 1, and Approval of a Site Plan for Caliber Kettlestone Plat 1 (915 & 845 SE Esker Ridge Drive) Melissa DeBoer, Planning Coordinator, introduced the request for approval of a preliminary plat/site plan and final plat for a multi-family residential development, as requested by MN Waukee Holdings LLC, represented by Eric Cannon of Snyder & Associates. The property is located north of SE Esker Ridge Drive and east of SE Parkview Crossing Drive, containing approximately 2.81 acres. The subject property is located within the Kettlestone Corridor and includes 2.81-acres. The property was rezoned in Fall 2020 and previously platted as an outlot as part of the final plat with The Shops at Kettlestone North Plat 5 in 2018. The project includes the construction of two apartment buildings. One building includes 42 units and is just under 34,000 square feet in area and one building includes 66 units and is just under 54,000 square feet in area. Both buildings are three stories and around 40-ft in height. The total proposed density is approximately 38 dwelling units per acre. Per the planned development, the maximum density allowed is 42 dwelling units per acre. The proposed number of dwelling units meets the requirements of the planned development. The site plan also includes a trash enclosure located along the north side of the site, between the two buildings. The final plat includes two lots. Lot 1 is 1.14 acres in area and Lot 2 is 1.68 acres in area. Each lot contains one apartment building. The final plat includes several easements for utilities where necessary and ingress/egress easements to provide access across the lots. Three accesses will be provided into the development. One will be provided from the private drive along the north, one will be provided from SE Encompass Drive, and one access will be provided from SE Esker Ridge Drive along the south. A 10-foot-wide trail will be provided along the south side of the site, adjacent to SE Esker Ridge Drive. A 10- foot-wide trail exists along the west side of the site, adjacent to SE Parkview Crossing Drive. Existing sidewalks have been provided along the other sides of the property adjacent to the surrounding streets. Several pedestrian connections are provided into the site from the adjacent public trails and sidewalks. Several sidewalks are provided throughout the property to provide access around the buildings and parking areas. A total of 158 parking spaces are required for this project and a total of 160 spaces are provided, including 6 accessible parking stalls. Public utilities are provided to the site. Storm water detention will be provided with an underground detention facility, located at the north end of the site, on Lot 2. A minimum of 20% of the project area is required to be open space. The total amount of open space proposed is 20.7%. Plantings are being provided throughout the site in compliance with the Landscape & Open Space Ordinance and the Kettlestone Design Guidelines. The elevations of the buildings are proposed to be constructed of brick, fiber cement lap siding, and glazing. The trash enclosure is proposed to be constructed of brick to match the building with metal gates. Elevations of the proposed buildings and trash enclosure have been provided for review. A photometric plan for the site lighting has been submitted and complies with the requirements of the Site Plan Ordinance. All proposed easements have been indicated on the final plat. Private utility easements are provided across the site. Public ingress/egress easements are provided for access across the site. Due to its residential nature, parkland dedication is required to be provided. Based on the total number of units proposed, the required amount of parkland dedication is 1.23-acres. The applicant intends to satisfy parkland dedication requirements with a fee in lieu of land dedication. The subject property is located within the Kettlestone Corridor. The land use shown within the Kettlestone Master Plan for the subject property is office. The Kettlestone Master Plan is intended to act as a guide for land use while at the same time allowing for flexibility of land uses. The intent is that the land use designations can move based upon market demands. The property was rezoned in 2020 to allow for mixed use development, including multi-family residential. The proposed preliminary plat/site plan and final plat are in general conformance with the Zoning Ordinance, Subdivision Ordinance, Site Plan Ordinance, Comprehensive Plan, and Kettlestone Design Guidelines. Staff recommends approval subject to any remaining staff comments and review of the legal documents. Discussion as follows: • General discussion of the building and appearance, confirmation that it will be similar to Kettlestone Central Lofts • Discussion of how the fee in lieu of parkland is calculated; based on density and city code requirements but generally suggested as $35,000 per acre of required parkland Motion by Commissioner Tuel for Approval of a Preliminary Plat for Caliber Kettlestone Plat 1, seconded by Commissioner Bankole. Ayes: Broderick, Bankole, Beenken, Lohse, Tuel, and Bannister. Nays: None. Motion carried. Motion by Commissioner Broderick for Approval of a Final Plat for Caliber Kettlestone Plat 1, seconded by Commissioner Lohse. Ayes: Broderick, Bankole, Beenken, Lohse, Tuel, and Bannister. Nays: None. Motion carried. Motion by Commissioner Lohse for Approval of a Site Plan for Caliber Kettlestone Plat 1, seconded by Commissioner Bannister. Ayes: Broderick, Bankole, Beenken, Lohse, Tuel, and Bannister. Nays: None. Motion carried. RECOMMENDATION: Approve the resolutions ATTACHMENTS: I. Proposed Resolutions II. Staff Report III. Preliminary Plat/Site Plan IV. Final Plat V. Building Elevations PREPARED BY: Melissa DeBoer, Planning Coordinator REVIEWED BY: PUBLIC NOTICE INFORMATION – NAME OF PUBLICATION: DATE OF PUBLICATION: THE CITY OF WAUKEE, IOWA RESOLUTION 2026- APPROVING THE PRELIMINARY PLAT FOR CALIBER KETTLESTONE PLAT 1 IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission reviewed and recommended approval of a Preliminary Plat for Caliber Kettlestone Plat 1 on February 10, 2026; AND, WHEREAS, the Preliminary Plat for Caliber Kettlestone Plat 1 is in general conformance with section §176 - Subdivision Regulations of the Waukee Municipal Code. NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this the 2nd day of March, 2026, that the Preliminary Plat for Caliber Kettlestone Plat 1 be approved subject to remaining staff comments. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Kala Anderson Chris Crone Rob Grove Lori Lyon Anna Bergman Pierce THE CITY OF WAUKEE, IOWA RESOLUTION 2026- APPROVING THE FINAL PLAT FOR CALIBER KETTLESTONE PLAT 1 IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, NJREC INC, has requested final plat approval of Caliber Kettlestone Plat 1 (the “Plat”); AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Plat on February 10, 2026, subject to remaining staff comments and review of the legal documents; AND, WHEREAS, the Final Plat for Caliber Kettlestone Plat 1 and the documents relating thereto will comply with section §176 – Subdivision Regulations of the Waukee Municipal Code. NOW, THEREFORE, BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 2nd day of March, 2026, that the Final Plat for Caliber Kettlestone Plat 1 be and the same is hereby accepted and approved by the City Council of the City of Waukee. BE IT FURTHER RESOLVED that the City of Waukee does hereby accept the following easements and documents to be filed with the Plat: 1. Public Utility Easement(s); 2. Public Sidewalk Easement; 3. Private Ingress/Egress Easement; and 4. Private Sanitary Sewer Easement ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Kala Anderson Chris Crone Rob Grove Lori Lyon Anna Bergman Pierce THE CITY OF WAUKEE, IOWA RESOLUTION 2026- APPROVING THE SITE PLAN FOR CALIBER KETTLESTONE PLAT 1 (915 & 845 SE ESKER RIDGE DRIVE) IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Site Plan for Caliber Kettlestone Plat 1, subject to remaining staff comments on February 10, 2026; AND, WHEREAS, the Site Plan for Caliber Kettlestone Plat 1 is in general conformance with §160 – Site and Building Development Standards Ordinance of the Waukee Municipal Code; AND, WHEREAS, the Site Plan for Caliber Kettlestone Plat 1 is in general conformance with §161 – Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND, NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 2nd day of March, 2026, that the Site Plan for Caliber Kettlestone Plat 1 is approved. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Kala Anderson Chris Crone Rob Grove Lori Lyon Anna Bergman Pierce PLANNING AND ZONING COMMISSION STAFF REPORT PROJECT: Caliber Kettlestone Plat 1 – Preliminary Plat / Site Plan and Final Plat PREPARED BY: Melissa DeBoer, AICP – Planning Coordinator REPORT DATE: February 5, 2026 MEETING DATE: February 10, 2026 GENERAL INFORMATION Owner/Applicant: MN Waukee Holdings LLC Owner’s Representative: Eric Cannon, P.E. with Snyder & Associates Request: The applicant is requesting approval of a preliminary plat/site plan and final plat for a multi-family residential development. Location and Size: Property is located north of SE Esker Ridge Drive and east of SE Parkview Crossing Drive, containing approximately 2.81 acres. Property Address: 915 & 845 SE Esker Ridge Drive AREA MAP ABOVE: Aerial of subject property (outlined in BLUE) in relation to the surrounding area. February 11, 2026 2 of 4 LAND USES AND ZONING Location Existing Land Use Kettlestone Master Plan Current Zoning Property in Question Vacant – Undeveloped Office K-MU (Kettlestone Mixed Use District) / PD-1 (Planned Development Overlay District) North Office Commercial Office K-OF (Kettlestone Office District) and K-OF (Kettlestone Office District) / PD-1 (Planned Development Overlay District) South Vacant – Undeveloped Retail Community K-RR (Kettlestone Retail Regional District) / PD-1 (Planned Development Overlay District) East Vacant – Undeveloped (Future Community Choice Credit Union) / Office / Multi- Family Residential Office K-RC (Kettlestone Retail Community District), K-OF (Kettlestone Office District) / PD- 1 (Planned Development Overlay District), and K-MF-HIGH (Kettlestone Multi-Family Stacked High District) / PD-1 (Planned Development Overlay District) West Vacant – Undeveloped Office & Retail Community K-OF (Kettlestone Office District) and K-RC (Kettlestone Retail Community District) / PD-1 (Planned Development Overlay District) BACKGROUND The subject property is located within the Kettlestone Corridor and includes 2.81-acres. The property was rezoned in Fall 2020 and previously platted as an outlot as part of the final plat with The Shops at Kettlestone North Plat 5 in 2018. PROJECT DESCRIPTION The project includes the construction of two apartment buildings. One building includes 42 units and is just under 34,000 square feet in area and one building includes 66 units and is just under 54,000 square feet in area. Both buildings are three stories and around 40-ft in height. The total proposed density is approximately 38 dwelling units per acre. Per the planned development, the maximum density allowed is 42 dwelling units per acre. The proposed number of dwelling units meets the requirements of the planned development. The site plan also includes a trash enclosure located along the north side of the site, between the two buildings. The final plat includes two lots. Lot 1 is 1.14 acres in area and Lot 2 is 1.68 acres in area. Each lot contains one apartment building. The final plat includes several easements for utilities where necessary and ingress/egress easements to provide access across the lots. February 11, 2026 3 of 4 ACCESS AND PARKING Three acceses will be provided into the development. One will be provided from the private drive along the north, one will be provided from SE Encompass Drive, and one access will be provided from SE Esker Ridge Drive along the south. A 10-foot-wide trail will be provided along the south side of the site, adjacent to SE Esker Ridge Drive. A 10- foot-wide trail exists along the west side of the site, adjacent to SE Parkview Crossing Drive. Existing sidewalks have been provided along the other sides of the property adjacent to the surrounding streets. Several pedestrian connections are provided into the site from the adjacent public trails and sidewalks. Several sidewalks are provided throughout the property to provide access around the buildings and parking areas. A total of 158 parking spaces are required for this project and a total of 160 spaces are provided, including 6 accessible parking stalls. UTILITIES Public utilities are provided to the site. Storm water detention will be provided with an underground detention facility, located at the north end of the site, on Lot 2. LANDSCAPING & OPEN SPACE A minimum of 20% of the project area is required to be open space. The total amount of open space proposed is 20.7%. Plantings are being provided throughout the site in compliance with the Landscape & Open Space Ordinance and the Kettlestone Design Guidelines. ELEVATIONS The elevations of the buildings are proposed to be constructed of brick, fiber cement lap siding, and glazing. The trash enclosure is proposed to be constructed of brick to match the building with metal gates. Elevations of the proposed buildings and trash enclosure have been provided for review. LIGHTING PLAN A photometric plan for the site lighting has been submitted and complies with the requirements of the Site Plan Ordinance. EASEMENTS All proposed easements have been indicated on the final plat. Private utility easements are provided across the site. Public ingress/egress easements are provided for access across the site. PARKLAND DEDICATION Due to its residential nature, parkland dedication is required to be provided. Based on the total number of units proposed, the required amount of parkland dedication is 1.23-acres. The applicant intends to satisfy parkland dedication requirements with a fee in lieu of land dedication. COMPREHENSIVE PLAN The subject property is located within the Kettlestone Corridor. The land use shown within the Kettlestone Master Plan for the subject property is office. The Kettlestone Master Plan is intended to act as a guide for land use while at the same time allowing for flexibility of land uses. The intent is that the land use designations can move based upon market demands. The property was rezoned in 2020 to allow for mixed use development, including multi-family residential. February 11, 2026 4 of 4 STAFF RECOMMENDATION The proposed preliminary plat/site plan and final plat are in general conformance with the Zoning Ordinance, Subdivision Ordinance, Site Plan Ordinance, Comprehensive Plan, and Kettlestone Design Guidelines. Staff recommends approval subject to any remaining staff comments and review of the legal documents. BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m ED C LJ M LM W 12 - 0 9 - 2 5 20 0 ' 12 5 . 1 3 9 6 . 0 1 C1 0 0 125.1396.01 C100 CA L I B E R K E T T L E S T O N E P L A T 1 TI T L E S H E E T WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 12 - 2 3 - 2 5 01 - 0 6 - 2 6 01 - 2 0 - 2 6 02 - 0 3 - 2 6 LJ M LJ M LJ M LJ M 1234 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 5 \ 1 2 5 . 1 3 9 6 . 0 1 0 \ C A D D \ S P _ 1 2 5 1 3 9 6 _ T S H . d w g LO G A N M Y E R S , TI T L E S H E E T , 20 2 6 / 0 2 / 0 3 , 2: 2 3 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 200 SITE PLAN / PRELIMINARY PLAT FOR CALIBER KETTLESTONE PLAT 1 915 & 845 SE ESKER RIDGE DRIVE CITY OF WAUKEE, DALLAS COUNTY, IOWA SNYDER & ASSOCIATES 2727 SW SNYDER BLVD. ANKENY, IOWA 50023 CONTACT: ERIC CANNON, P.E. PHONE: (515) 964-2020 VICINITY MAP PROJECT LOCATION ENGINEER SE E S K E R R I D G E D R SE E N C O M P A S S D R C100-C401, C600-C601 C500GR A N D P R A I R I E P K W Y I hereby certify that this engineering document was prepared by me or under my direct personal supervision and that I am a duly licensed Professional Engineer under the laws of the State of Iowa. Eric D. Cannon, P.E.Date License Number P18954 My License Renewal Date is December 31, 2027 Pages or sheets covered by this seal: ERIC D. CANNON P18954 DPROFE L NSE ICE IONALENGINEER AIOW SS P EF RO SSONLA I ACPNALCDS CARH E CE T TII A ETST F IO AWO License Expires: June 30, 2027 CLAY R. SCHNECKLOTH 512 LANDSCAPE ARCHITECT NO. Clay R. Schneckloth, PLA License Number Pages or sheets covered by this seal: 512 Date I hereby certify that the portion of this technical submission described below was prepared by me or under my direct supervision and responsible charge. I am a duly licensed Professional Landscape Architect under the laws of the State of Iowa. SE P A R K V I E W C R O S S I N G D R I V E OWNER MN WAUKEE HOLDINGS LLC 1409 N RIVERFRONT DR MANKATO, MN 56001 Sheet List Table Sheet Number Sheet Title C100 TITLE SHEET C101 PROJECT INFORMATION C200 DIMENSION PLAN C300 UTILITY PLAN C400 GRADING AND EROSION CONTROL PLAN C401 DETAILED GRADING PLAN C402 RAMP DETAILS C500 PLANTING PLAN C600 SITE DETAILS C601 SITE DETAILS ARCHITECT J CORP DESIGN BUILD 3611 NE OTTERVIEW CIRCLE #42 ANKENY, IOWA 50021 CONTACT: NICK JENSEN PHONE: (515) 290-3401 BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m ED C LJ M LM W 12 - 0 9 - 2 5 12 5 . 1 3 9 6 . 0 1 C1 0 1 125.1396.01 C101 CA L I B E R K E T T L E S T O N E P L A T 1 PR O J E C T I N F O R M A T I O N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 12 - 2 3 - 2 5 01 - 0 6 - 2 6 01 - 2 0 - 2 6 02 - 0 3 - 2 6 LJ M LJ M LJ M LJ M 1234 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 5 \ 1 2 5 . 1 3 9 6 . 0 1 0 \ C A D D \ S P _ 1 2 5 1 3 9 6 _ T S H . d w g LO G A N M Y E R S , PR O J E C T I N F O R M A T I O N , 20 2 6 / 0 2 / 0 3 , 2: 2 3 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) UTILITY QUALITY SERVICE LEVELS QUALITY LEVELS OF UTILITIES ARE SHOWN IN THE PARENTHESES WITH THE UTILITY TYPE AND WHEN APPLICABLE, SIZE. THE QUALITY LEVELS ARE BASED ON THE CI / ASCE 38-02 STANDARD. QUALITY LEVEL (D) INFORMATION IS DERIVED FROM EXISTING UTILITY RECORDS OR ORAL RECOLLECTIONS. QUALITY LEVEL (C) INFORMATION IS OBTAINED BY SURVEYING AND PLOTTING VISIBLE ABOVE-GROUND UTILITY FEATURES AND USING PROFESSIONAL JUDGMENT IN CORRELATING THIS INFORMATION WITH QUALITY D INFORMATION. QUALITY LEVEL (B) INFORMATION IS OBTAINED THROUGH THE APPLICATION OF APPROPRIATE SURFACE GEOPHYSICAL METHODS TO DETERMINE THE EXISTENCE AND APPROXIMATE HORIZONTAL POSITION OF SUBSURFACE UTILITIES. QUALITY LEVEL (A) IS HORIZONTAL AND VERTICAL POSITION OF UNDERGROUND UTILITIES OBTAINED BY ACTUAL EXPOSURE OR VERIFICATION OF PREVIOUSLY EXPOSED SUBSURFACE UTILITIES, AS WELL AS THE TYPE, SIZE, CONDITION, MATERIAL, AND OTHER CHARACTERISTICS. UTILITY WARNING THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR RECORDS OBTAINED. THE SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES OR SUBSURFACE FEATURES SHOWN COMPRISE ALL SUCH ITEMS IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UTILITIES OR SUBSURFACE FEATURES SHOWN ARE IN THE EXACT LOCATION INDICATED EXCEPT WHERE NOTED AS QUALITY LEVEL A. FEATURES EXISTING PROPOSED Spot Elevation Contour Elevation Fence (Barbed, Field, Hog) Fence (Chain Link) Fence (Wood) Fence (Silt) Tree Line Tree Stump Deciduous Tree \\ Shrub Coniferous Tree \\ Shrub Communication Overhead Communication Fiber Optic Underground Electric Overhead Electric Gas Main with Size High Pressure Gas Main with Size Water Main with Size Sanitary Sewer with Size Duct Bank Test Hole Location for SUE w/ID (*) Denotes the survey quality service level for utilities Sanitary Manhole Storm Sewer with Size Storm Manhole Single Storm Sewer Intake Double Storm Sewer Intake Fire Hydrant Fire Hydrant on Building Water Main Valve Water Service Valve Well Utility Pole Guy Anchor Utility Pole with Light Utility Pole with Transformer Street Light Yard Light Electric Box Electric Transformer Traffic Sign Communication Pedestal Communication Manhole Communication Handhole Fiber Optic Manhole Fiber Optic Handhole Gas Valve Gas Manhole Gas Apparatus Fence Post or Guard Post Underground Storage Tank Above Ground Storage Tank Sign Satellite Dish Mailbox Sprinkler Head Irrigation Control Valve LEGEND ○ 122 5 X 1225.25 ● X122 5 1225.25 FEATURES FOUND SET Section Corner 1/2" Rebar, Cap # 11579 (Unless Otherwise Noted) ROW Marker ROW Rail Control Point Bench Mark Platted Distance P Measured Bearing & Distance M Recorded As R Deed Distance D Calculated Distance C Minimum Protection Elevation MPE Centerline Section Line 1/4 Section Line 1/4 1/4 Section Line Easement Line NOTES A. NOTIFY UTILITY PROVIDERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES AND COORDINATE WITH UTILITY PROVIDERS AS NECESSARY DURING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXISTENCE, EXACT LOCATION, AND DEPTH OF ALL UTILITIES. PROTECT ALL UTILITY LINES AND STRUCTURES NOT SHOWN FOR REMOVAL OR MODIFICATION. ANY DAMAGES TO UTILITY ITEMS NOT SHOWN FOR REMOVAL OR MODIFICATION SHALL BE REPAIRED TO THE UTILITY OWNER'S SPECIFICATIONS AT THE CONTRACTOR'S EXPENSE. B. CONSTRUCTION OF ALL STREET AND UTILITY IMPROVEMENTS SHALL CONFORM TO THE 2025 WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS, 2025 STATEWIDE URBAN DESIGN AND SPECIFICATIONS (SUDAS) AND THE SOILS REPORTS PREPARED BY OTHERS. C. LENGTH OF UTILITIES SHOWN ON PLANS ARE DIMENSIONED FROM CENTERLINE OF STRUCTURE TO CENTERLINE OF STRUCTURE. D. ALL TRAFFIC CONTROL SHALL BE PROVIDED IN ACCORDANCE WITH REQUIREMENTS SET FORTH IN THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). WHEN CONSTRUCTION ACTIVITIES OBSTRUCT PORTIONS OF THE ROADWAY, FLAGGERS SHALL BE PROVIDED. FLAGGERS SHALL CONFORM TO THE MUTCD IN APPEARANCE, EQUIPMENT AND ACTIONS. THE CONTRACTOR SHALL NOTIFY THE CITY OF WAUKEE AT LEAST ONE WEEK PRIOR TO ANY ANTICIPATED LANE CLOSURE. E. NOTIFY OWNER, ENGINEER, CITY OF WAUKEE AT LEAST 48 HOURS PRIOR TO BEGINNING WORK. CONTRACTOR SHALL ALSO NOTIFY THE CITY OF WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT AT LEAST 48 HOURS PRIOR TO ANY PLANNED WEEKEND OR HOLIDAY WORK. F. CONSTRUCT MANHOLES AND APPURTENANCES AS WORK PROGRESSES. BACKFILL WITH SUITABLE MATERIAL AND COMPACT TO 95% MAXIMUM DENSITY. G. IN THE EVENT OF A DISCREPANCY BETWEEN THE QUANTITY ESTIMATES AND THE DETAILED PLANS, THE DETAILED PLANS SHALL GOVERN. H. ALL FIELD TILES ENCOUNTERED DURING CONSTRUCTION SHALL BE RECONNECTED OR REPAIRED AND NOTED ACCORDINGLY ON THE AS-BUILT DOCUMENTS. I. DIMENSIONS, BUILDING LOCATION, UTILITIES AND GRADING OF THIS SITE ARE BASED ON AVAILABLE INFORMATION AT THE TIME OF DESIGN. DEVIATIONS MAY BE NECESSARY IN THE FIELD. ANY SUCH CHANGES OR CONFLICTS BETWEEN THIS PLAN AND FIELD CONDITIONS ARE TO BE REPORTED TO THE ARCHITECT/ENGINEER PRIOR TO STARTING CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LAYOUT VERIFICATION OF ALL SITE IMPROVEMENTS PRIOR TO CONSTRUCTION. CONTACT CITY OF WAUKEE FOR APPROVAL OF ANY CHANGES AND THAT ANY CHANGES COMPLETED WITHOUT APPROVAL ARE SUBJECT TO REMOVAL IN ORDER TO MEET THE CITY OF WAUKEE STANDARDS. J. CONTRACTOR TO LOAD AND TRANSPORT ALL MATERIALS CONSIDERED TO BE UNDESIRABLE TO BE INCORPORATED INTO THE PROJECT TO AN APPROVED OFF-SITE WASTE SITE. K. CONTRACTOR TO STRIP AND STOCKPILE TOPSOIL FROM ALL AREAS TO BE CUT OR FILLED. RESPREAD TO MINIMUM 8" DEPTH TO FINISH GRADES TO CONFORM TO SUDAS SPECIFICATIONS SECTION 2010. L. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS SHOWN ARE FINISHED GRADES AND/OR TOP OF PAVING SLAB (GUTTER), UNLESS OTHERWISE NOTED. M. THE CONTRACTOR IS RESPONSIBLE FOR CLEANING DIRT AND DEBRIS FROM NEIGHBORING STREETS, DRIVEWAYS, AND SIDEWALKS CAUSED BY CONSTRUCTION ACTIVITIES AT THE END OF EACH WORK DAY AND PRIOR TO A RAIN EVENT. N. THE ADJUSTMENT OF ANY EXISTING UTILITY APPURTENANCES TO FINAL GRADE IS CONSIDERED INCIDENTAL TO THE SITE WORK. O. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING EROSION AND SEDIMENT CONTROL MEASURES AS NECESSARY. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR MAINTAINING ANY EXISTING EROSION CONTROL MEASURES ON SITE AT THE TIME OF CONSTRUCTION. GRADING AND SOIL EROSION CONTROL CODE REQUIREMENTS SHALL BE MET BY CONTRACTOR. A COSESCO PERMIT IS REQUIRED FOR THIS PROJECT. P. CONTRACTOR TO COORDINATE NATURAL GAS, ELECTRICAL, TELEPHONE AND ANY OTHER FRANCHISE UTILITY SERVICES WITH UTILITY SERVICE PROVIDER, CITY OF WAUKEE, AND THE OWNER PRIOR TO CONSTRUCTION. Q. IF STORM SEWER CROSSES ABOVE WATER MAIN OR CROSSES LESS THAN 18" BELOW A WATER MAIN THEN STORM SEWER SHALL BE CONSTRUCTED OF REINFORCED CONCRETE WITH A FLEXIBLE O-RING GASKET RATED AT 13 PSI OR GREATER. O-RING GASKET JOINTS SHALL BE INSTALLED ON EACH SIDE OF THE CROSSING UNTIL THE NORMAL DISTANCE FROM THE WATER MAIN TO THE STORM SEWER IS AT LEAST TEN FEET. R. A PRE-CONSTRUCTION MEETING WITH THE CITY OF WAUKEE WILL BE REQUIRED A MINIMUM OF ONE WEEK PRIOR TO CONSTRUCTION ACTIVITIES BEGINNING. S. ALL STAKING SHALL BE DONE UNDER THE DIRECTION OF A LICENSED ENGINEER OR LAND SURVEYOR INCLUDING PEDESTRIAN FACILITIES. T. ANY CHANGES PROPOSED TO THE DRAWINGS DURING CONSTRUCTION SHALL BE APPROVED IN WRITING BY THE CITY OF WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT PRIOR TO CONSTRUCTION. U. THE CONTRACTOR IS RESPONSIBLE FOR ANY CHANGES MADE DURING CONSTRUCTION THAT HAVE NOT BEEN GRANTED APPROVAL IN WRITING BY THE CITY OF WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT. V. ALL SANITARY SEWER AND STORM SEWER SHALL BE CLEANED AND TELEVISED PRIOR TO PAVING. THE CITY OF WAUKEE SHALL WITNESS ALL CLEANING AND TELEVISING. COPIES OF THE REPORT AND VIDEO SHALL BE PROVIDED TO THE CITY OF WAUKEE. ALL SANITARY SEWER MANHOLES SHALL BE VACUUM TESTED. W. ALL CONNECTIONS TO EXISTING SANITARY MANHOLES SHALL BE CORE DRILL WITH A LINK SEAL. X. PLACE 3/4" EXPANSION JOINT BETWEEN ALL PCC PAVEMENT/SIDEWALKS AND BUILDINGS. PLACE 1/2" EXPANSION JOINT BETWEEN SIDEWALKS AND PCC PAVEMENT. THE PCC RAMP JOINT LOCATED AT THE BACK OF CURB AND ALL EXPANSION JOINTS SHALL BE SEALED. Y. AS-BUILTS SHALL BE PROVIDED TO THE WAUKEE ENGINEERING DEPARTMENT INCLUDING ALL UTILITIES AND AS-BUILT GRADES FOR DRAINAGE SWALES, OVERFLOWS, ACCESSIBLE RAMPS AND DETENTION FACILITIES. THE CONTRACTOR SHALL PROVIDE INFORMATION TO THE DESIGN ENGINEER FOR INCLUSION ON THE RECORD AS-BUILT DRAWINGS. Z. ALL UTILITIES INCLUDING PRIVATE UTILITIES SHALL BE CONSTRUCTED TO THE CITY OF WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND ALL UTILITIES SHALL BE TESTED TO CITY STANDARDS. THE CITY SHALL WITNESS ALL TESTING. AA. CONSTRUCTION OPERATIONS SHALL PROTECT STORM SEWERS AND DRAINAGE WAYS FROM ALLOWING CONCRETE SLURRY FROM CONCRETE OPERATIONS TO DISCHARGE OFFSITE. BB. CONTRACTOR SHALL COORDINATE ALL TIE-IN TO UTILITIES WITH THE CITY OF WAUKEE PUBLIC WORKS DEPARTMENT AND CITY OF WAUKEE PUBLIC WORKS SHALL WITNESS ALL TIE-INS. CC. ALL SIGNAGE IS TO BE REVIEWED UNDER SEPARATE SIGN PERMIT PROCESS. GENERAL USE APARTMENTS PROPERTY DESCRIPTION THE SHOPS AT KETTLESTONE NORTH PLAT 10, LOTS 1 & 2 PROPERTY ADDRESS 915 & 845 SE ESKER RIDGE DRIVE WAUKEE, IOWA 50263 ZONING K-MU/PD-1 OVERLAY: KETTLESTONE MULTI-FAMILY/ PLANNED DEVELOPMENT DISTRICT OVERLAY (BK 2020, PG 25377) (PER ZONING ORDINANCE #2970) OPEN SPACE LOT 1: SITE AREA: 49,530 SF (1.14 AC) IMPERVIOUS AREA:36,206 SF (73.1%) OPEN SPACE AREA:13,324 SF (26.9%) LOT 2: SITE AREA: 73,073 SF (1.68 AC) IMPERVIOUS AREA:54,025 SF (73.9%) OPEN SPACE AREA:19,048 SF (26.1%) BULK REGULATIONS LOT AREA: NO MINIMUM REQUIREMENT LOT WIDTH: NO MINIMUM REQUIREMENT FRONT YARDS: NO MINIMUM FOR PRINCIPAL PERMITTED USES. 20 FEET FOR ACCESSORY STRUCTURES SIDE YARDS: NO MINIMUM FOR PRINCIPAL PERMITTED USES UNLESS ADJACENT TO ADJOINING SINGLE-FAMILY, IN WHICH CASE THE MINIMUM SETBACK SHALL BE 50 FEET. 5 FEET FOR ACCESSORY STRUCTURES. REAR YARD: NO MINIMUM FOR PRINCIPAL PERMITTED USES UNLESS ADJACENT TO ADJOINING SINGLE-FAMILY, IN WHICH CASE THE MINIMUM SETBACK SHALL BE 50 FEET. 5 FEET FOR ACCESSORY STRUCTURES. MAXIMUM HEIGHT: PRINCIPAL BUILDING - 8 STORIES ACCESSORY BUILDING - 1 STORY PARKING REQUIREMENTS 1 SPACE PER BEDROOM 1 SPACE PER 5 UNITS 136 BEDROOMS = 136 SPACES REQUIRED 108 UNITS/ 5 = 22 SPACES REQUIRED 158 TOTAL SPACES REQUIRED 160 SPACES PROVIDED (INCLUDING 6 ACCESSIBLE SPACES) BUILDING DESCRIPTION LOT 1: 42-PLEX BUILDING= 33,993 SF BUILDING HEIGHT= 40'-6" (3 STORIES) PROPOSED FLOOR AREA RATIO: 0.23 LOT 2: 66-PLEX BUILDING= 53,970 SF BUILDING HEIGHT= 40'-6" (3 STORIES) PROPOSED FLOOR AREA RATIO: 0.25 POLLUTION PREVENTION NOTES A.POLLUTION PREVENTION AND EROSION PROTECTION 1.CODE COMPLIANCE: THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL POTENTIAL POLLUTION AND SOIL EROSION CONTROL REQUIREMENTS OF THE IOWA CODE, THE IOWA DEPARTMENT OF NATURAL RESOURCES (IDNR) NPDES PERMIT, THE U.S. CLEAN WATER ACT AND ANY LOCAL ORDINANCES. THE CONTRACTOR SHALL TAKE ALL NECESSARY STEPS TO PROTECT AGAINST EROSION AND POLLUTION FROM THIS PROJECT SITE AND ALL OFF-SITE BORROW OR DEPOSIT AREAS DURING PERFORMANCE OR AS A RESULT OF PERFORMANCE. 2.DAMAGE CLAIMS: THE CONTRACTOR WILL HOLD THE OWNER AND ARCHITECT / ENGINEER HARMLESS FROM ANY AND ALL CLAIMS OF ANY TYPE WHATSOEVER RESULTING FROM DAMAGES TO ADJOINING PUBLIC OR PRIVATE PROPERTY, INCLUDING REASONABLE ATTORNEY FEES INCURRED TO OWNER. FURTHER, IF THE CONTRACTOR FAILS TO TAKE NECESSARY STEPS TO PROMPTLY REMOVE EARTH SEDIMENTATION OR DEBRIS WHICH COMES ONTO ADJOINING PUBLIC OR PRIVATE PROPERTY, THE OWNER MAY, BUT NEED NOT, REMOVE SUCH ITEMS AND DEDUCT THE COST THEREOF FROM AMOUNTS DUE TO THE CONTRACTOR. B.STORM WATER DISCHARGE PERMIT 1.THIS PROJECT REQUIRES COVERAGE UNDER THE NPDES GENERAL PERMIT NO. 2 FOR STORM WATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITIES FROM THE IDNR, AS REQUIRED BY THE ENVIRONMENTAL PROTECTION AGENCY (EPA). THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS ARE RESPONSIBLE FOR COMPLIANCE WITH AND FULFILLMENT OF ALL REQUIREMENTS OF THE NPDES GENERAL PERMIT NO. 2 AS SPECIFIED IN THE CONTRACT DOCUMENTS. 2.ALL DOCUMENTS RELATED TO THE STORM WATER DISCHARGE PERMIT, INCLUDING, BUT NOT LIMITED TO, THE NOTICE OF INTENT, PROOF OF PUBLICATIONS, DISCHARGE AUTHORIZATION LETTER, CURRENT SWPPP, SITE INSPECTION LOG, AND OTHER ITEMS, SHALL BE KEPT ON SITE AT ALL TIMES AND MUST BE PRESENTED TO ANY JURISDICTIONAL AGENCIES UPON REQUEST. FAILURE TO COMPLY WITH THE NPDES PERMIT REQUIREMENTS IS A VIOLATION OF THE CLEAN WATER ACT AND THE CODE OF IOWA. 3.A "NOTICE OF DISCONTINUATION" MUST BE FILED WITH THE IDNR UPON FINAL STABILIZATION OF THE DISTURBED SITE AND REMOVAL OF ALL TEMPORARY EROSION CONTROL MEASURES. ALL PLANS, INSPECTION REPORTS, AND OTHER DOCUMENTS MUST BE RETAINED FOR A PERIOD OF THREE YEARS AFTER PROJECT COMPLETION. THE CONTRACTOR SHALL RETAIN A RECORD COPY AND PROVIDE THE ORIGINAL DOCUMENTS TO THE OWNER UPON PROJECT ACCEPTANCE AND/OR SUBMITTAL OF THE NOTICE OF DISCONTINUATION. C.POLLUTION PREVENTION PLAN 1.THE STORM WATER POLLUTION PREVENTION PLAN (SWPPP) IS A SEPARATE DOCUMENT IN ADDITION TO THESE PLAN DRAWINGS. THE CONTRACTOR SHOULD REFER TO THE SWPPP FOR ADDITIONAL REQUIREMENTS AND MODIFICATIONS TO THE POLLUTION PREVENTION PLAN MADE DURING CONSTRUCTION. 2.THE SWPPP ILLUSTRATES GENERAL MEASURES AND BEST MANAGEMENT PRACTICES (BMP) FOR COMPLIANCE WITH THE PROJECT'S NPDES PERMIT COVERAGE. ALL BMP'S AND EROSION CONTROL MEASURES REQUIRED AS A RESULT OF CONSTRUCTION ACTIVITIES ARE THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY, NOTE AND IMPLEMENT. ADDITIONAL BMP'S FROM THOSE SHOWN ON THE PLAN MAY BE REQUIRED. 3.THE SWPPP AND SITE MAP SHOULD BE EXPEDITIOUSLY REVISED TO REFLECT CONSTRUCTION PROGRESS AND CHANGES AT THE PROJECT SITE. 4.THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL REQUIREMENTS OF THE GENERAL PERMIT AND SWPPP, INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING BMP'S UNLESS INFEASIBLE OR NOT APPLICABLE: a.UTILIZE OUTLET STRUCTURES THAT WITHDRAW WATER FROM THE SURFACE WHEN DISCHARGING FROM BASINS, PROVIDE AND MAINTAIN NATURAL BUFFERS AROUND SURFACE WATERS, DIRECT STORM WATER TO VEGETATED AREAS TO INCREASE SEDIMENT REMOVAL AND MAXIMIZE STORM WATER INFILTRATION, AND MINIMIZE SOIL COMPACTION. b.INSTALL PERIMETER AND FINAL SEDIMENT CONTROL MEASURES SUCH AS SILT BARRIERS, DITCH CHECKS, DIVERSION BERMS, OR SEDIMENTATION BASINS DOWNSTREAM OF SOIL DISTURBING ACTIVITIES PRIOR TO SITE CLEARING AND GRADING OPERATIONS. c.PRESERVE EXISTING VEGETATION IN AREAS NOT NEEDED FOR CONSTRUCTION AND LIMIT TO A MINIMUM THE TOTAL AREA DISTURBED BY CONSTRUCTION OPERATIONS AT ANY TIME. d.MAINTAIN ALL TEMPORARY AND PERMANENT EROSION CONTROL MEASURES IN WORKING ORDER, INCLUDING CLEANING, REPAIRING, REPLACEMENT, AND SEDIMENT REMOVAL THROUGHOUT THE PERMIT PERIOD. CLEAN OR REPLACE SILT CONTROL DEVICES WHEN THE MEASURES HAVE LOST 50% OF THEIR ORIGINAL CAPACITY. e.INSPECT THE PROJECT AREA AND CONTROL DEVICES (BY QUALIFIED PERSONNEL ASSIGNED BY THE CONTRACTOR) EVERY SEVEN CALENDAR DAYS. RECORD THE FINDINGS OF THESE INSPECTIONS AND ANY RESULTING ACTIONS IN THE SWPPP WITH A COPY SUBMITTED WEEKLY TO THE OWNER OR ENGINEER DURING CONSTRUCTION. REVISE THE SWPPP AND IMPLEMENT ANY RECOMMENDED MEASURES WITHIN 7 DAYS. f.PREVENT ACCUMULATION OF EARTH AND DEBRIS FROM CONSTRUCTION ACTIVITIES ON ADJOINING PUBLIC OR PRIVATE PROPERTIES, INCLUDING STREETS, DRIVEWAYS, SIDEWALKS, DRAINAGEWAYS, OR UNDERGROUND SEWERS. REMOVE ANY ACCUMULATION OF EARTH OR DEBRIS IMMEDIATELY AND TAKE REMEDIAL ACTIONS FOR FUTURE PREVENTION. g.INSTALL NECESSARY CONTROL MEASURES SUCH AS SILT BARRIERS, EROSION CONTROL MATS, MULCH, DITCH CHECKS OR RIPRAP AS SOON AS AREAS REACH THEIR FINAL GRADES AND AS CONSTRUCTION OPERATIONS PROGRESS TO ENSURE CONTINUOUS RUNOFF CONTROL. PROVIDE INLET AND OUTLET CONTROL MEASURES AS SOON AS STORM SEWERS ARE INSTALLED. h.RESPREAD A MINIMUM OF 8 INCHES OF TOPSOIL (INCLUDING TOPSOIL FOUND IN SOD) ON ALL DISTURBED AREAS, EXCEPT WHERE PAVEMENT, BUILDINGS OR OTHER IMPROVEMENTS ARE LOCATED. i.STABILIZE UNDEVELOPED, DISTURBED AREAS WITH MULCH, TEMPORARY SEED MIX, PERMANENT SEED MIX, SOD, OR PAVEMENT IMMEDIATELY AS SOON AS POSSIBLE UPON COMPLETION OR DELAY OF GRADING OPERATIONS. INITIATE STABILIZATION MEASURES IMMEDIATELY AFTER CONSTRUCTION ACTIVITY IS FINALLY COMPLETED OR TEMPORARILY CEASED ON ANY PORTION OF THE SITE AND WHICH WILL NOT RESUME FOR A PERIOD EXCEEDING 14 CALENDAR DAYS. j.COORDINATE LOCATIONS OF STAGING AREAS WITH THE OWNER AND RECORD IN THE SWPPP. UNLESS NOTED OTHERWISE, STAGING AREAS SHOULD CONTAIN THE FOLLOWING: JOB TRAILERS, FUELING / VEHICLE MAINTENANCE AREA, TEMPORARY SANITARY FACILITIES, MATERIALS STORAGE, AND CONCRETE WASHOUT FACILITY. CONTROL RUNOFF FROM STAGING AREAS WITH DIVERSION BERMS AND/OR SILT BARRIERS AND DIRECT TO A SEDIMENT BASIN OR OTHER CONTROL DEVICE WHERE POSSIBLE. CONCRETE WASHOUT MUST BE CONTAINED ONSITE. k.REMOVE ALL TEMPORARY EROSION CONTROL MEASURES AND SITE WASTE PRIOR TO FILING OF THE "NOTICE OF DISCONTINUATION". UTILITY CONTACT INFORMATION UTILITY CONTACT FOR MAPPING INFORMATION SHOWN AS RECEIVED FROM THE IOWA ONE CALL DESIGN REQUEST SYSTEM, TICKET NUMBER 552402093. FO1-FIBER OPTIC CENTURYLINK SADIE HULL (918)-547-0147 SADIE.HULL@LUMEN.COM FO14-FIBER OPTIC CONSOLIDATED COMMUNICATIONS PHILLIP WILLIAMS JR (515)-867-4769 PHILLIP.WILLIAMS@CONSOLIDATED.COM FO4-FIBER OPTIC AUREON NETWORK SERVICES JEFF KLOCKO (515)-830-0445 JEFF.KLOCKO@AUREON.COM UE1-UNDERGROUND ELECTRIC MIDAMER-ELEC JAMIE NEER (515)-252-6972 MECDSMDESIGNLOCATES@MIDAMERICAN.COM NO RESPONSE MI-FIBER JUSTIN MILLER (515)-897-8802 JMILLER@MI-FIBER.NET FO8-FIBER OPTIC UNITE PRIVATE NETWORKS,LLC JOE KILZER (816)-425-3556 UPNGIS@UPNFIBER.COM W1-WATER MAIN WAUKEE, CITY OF ST1-STORM SEWER TIM ROYER (515)-987-4363 TROYER@WAUKEE.ORG FIRE SAFETY CONSTRUCTION NOTE A. APPROVED FIRE APPARATUS ACCESS ROADS SHALL BE PROVIDED AS SOON AS CONSTRUCTION COMMENCES. IF PAVING IS NOT INSTALLED PRIOR TO BUILDING CONSTRUCTION COMMENCING AFTER FOOTING INSTALLED, AN APPROVED ROUTE AROUND THE EXTERIOR OF THE BUILDING TO EXTEND WITHIN 100 FEET OF ALL PORTIONS OF THE EXTERIOR WALLS SHALL BE PROVIDED AND COMPLY WITH THE REQUIREMENTS OF SECTION 503.2 OF THE IFC. CONTROL POINTS IOWA SOUTH STATE PLANE COORDINATE SYSTEM NAD83(2011)(EPOCH 2010.00) IARTN DERIVED - US SURVEY FEET CP1 N=576871.36 E=1543103.37 Z=1042.23 FOUND CUT "X" ON TOP CURB LOCATED SOUTH SIDE OF SE ESKER RIDGE DRIVE, WEST OF MCDONALDS ENTRANCE, AND +-400' WEST OF GRAND PRAIRIE PARKWAY. (AS SHOWN ON SURVEY) CP3 N=577228.02 E=1543322.21 Z=1036.07 FOUND CUT "X" ON TOP CURB LOCATED NORTHSIDE SE COMPASS DRIVE, WEST SIDE OF PARKING LOT ENTRANCE, +-350' WEST OF GRAND PRAIRIE PARKWAY. (AS SHOWN ON SURVEY) CP100 N=577100.24 E=1542841.62 Z=1045.14 SET CUT "X" ON TOP CURB LOCATED NORTH SIDE OF SE ESKER RIDGE DRIVE, +-60' WEST OF CENTERLINE OF SE PARKVIEW CROSSING DRIVE, AT DOUBLE BACK OF CURB INTAKE STRUCTURE. (AS SHOWN ON SURVEY) CP101 N=577493.07 E=1543002.47 Z=1036.55 SET CUT "X" ON TOP CURB LOCATED EAST SIDE OF PARKVIEW CROSSING DRIVE AT MID-RADIUS OF ENTRANCE, +-15' NORTH OF STORM MANHOLE. (AS SHOWN ON SURVEY) BENCHMARKS NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88 - GEOID18) IARTN DERIVED - US SURVEY FEET BM501 N=576952- E=1543062- Z=1044.39 NW UPPER FLANGE BOLT ON HYDRANT LOCATED EAST OF PARKVIEW CROSSING DRIVE, NORTH OF SE ESKER DRIVE. (AS SHOWN ON SURVEY) 10 15 3 7 11 6 12 14 8 11 12 9 10 14 9 TRASH 9 UP ST A I R ST A I R UP ST A I R ST A I R 42-PLEX 33,993 SF 66-PLEX 53,970 SF T T Outlot 'U' The Shops At Kettlestone North Plat 1 (Bk 2017, Pg 3256) 91,225 SF 2.09 AC LOT 1 TRAS H 14 16 18 8 9 16 12 411 10 7 2 UP 51 0 5 S F FU T U R E R E S T A U R A N T 10 9 489 S F EN T R Y 102 218 S F WO M E N 10 4 15 7 S F ME N10 3 38 S F UT I L . 11 0 VE N T CH A S E AB O V E SE R V I C E E N T R Y D3 D10 D1 6 D7 13 6 S F VE S T I B U L E 10 1 74 S F VE S T I B U L E 108D4 D1 D9D6 FLO O R / R O O F A B O V E FL O O R / R O O F A B O V E RO O F A B O V E RO O F A B O V E FLOO R / R O O F A B O V E ROOF A B O V E RO O F A B O V E D15 D17 D18 D18 D18 D18 D17 D3 D1 6 D14 PROP O S E D BUILD I N G 10,84 3 S F FFE= 1 0 4 1 . 9 0 S2 6 ° 5 5 ' 1 9 " W 3 2 2 . 7 1 ' M S2 6 ° 4 1 ' 3 0 " W 3 2 2 . 7 1 ' R S89°39'24"E 166.54' M S89°53'50"E 166.59' R S61°28'13"E 1.86' M S61°42'02"E 1.86' R 30' Storm Sewer Easement (Book 2017, Page 3266) Ingress/Egress Easement (Width Varies (Inst. No. 2025-16190) Ingress/Egress Easement (Width Varies) (Inst. No. 2025-16190) 30' Temporary Construction Easement (Inst. No. 2025-16190) Public 15' Water Main Easement (Book 2019, Page 10432) Public 62' Ingress/Egress Easement (Book 2019, Page 10433) Public 6 2 ' I n g r e s s / E g r e s s Easeme n t (Book 2 0 1 9 , P a g e 1 0 4 3 3 ) 20' Sanitary Sewer Easement (Book 2019, Page 10436) S1°27'18"E 47.22' M S1°43'08"E 47.15' R 49,530 SF 1.14 AC LOT 1 73,073 SF 1.68 AC LOT 2 32 . 9 1 ' 1 3 100 BM501 SEESKERRIDGEDRIVE CON C R E T E GRA V E L CO N C R E T E S I D E W A L K CO N C R E T E S I D E W A L K SE PARKVIEW CROSSING DRIVE CO N C R E T E CONCRETE CONCRETE SIDEWALK CONCRETE CO N C R E T E CO N C R E T E S I D E W A L K CON C R E T E S I D E W A L K SEENCOMPASSDRIVE FIL L P I L E 3L 3L 3A 3A 3A 3A 3A 3A 3A 3C 6A 1B 1A 1B 4A 4A 4A 4A S88°07'26"W 49.03' S2 6 ° 5 5 ' 1 9 " W 2 7 7 . 3 7 ' C6 N63°04'41"W 24.97' 28 9 . 8 0 ' 32 . 9 1 ' 3C 4A 4A 4A 3L 3L 4B 4C 4C 5A 5A 3I 3J 3J 4C 4C 4B 3D 3D 3D 3C 3C 3D 3F 3F 3F 3F 3B 3B 3G 3G 3H 3H 3H 3H 3H 3H 3H 3B3E 3D 3D 3D 3H 3D 3D 3D 3D 3D 3D 3B 3B 5A 5A 26 ' I n g r e s s /E g r e s s Ea s e m e n t 3D3D 3D 3D 3D3D 3B 3D 3B 3E 3E 3B 3D 3D 3D7 7 3I 3H 3H 18' 6' 2A 1B 1B 1B 1B 1A 1A 1A 1B 1B 1B 1B 1B 1B 6' 18' 26' 18' 6' 3G 3G 6' 18' 26' 18 ' 5' 3K 3K 3H 3H 18 ' 24 ' 20 ' 20 ' 24 ' 18 ' 6' R200' R23 0 ' R15' R5 ' R5' R15 ' R5' R4' R4 ' R5 ' R5 ' R5 'R5' R5' R5' R5' 6B 6B 20' Sanitary Sewer Easement 10' PUE 10' PUE 2B 2B 2B 1A 1B 3A3A 3A 3A 3A 3A 3A 3L 5' Sidewalk Easement 3E 3B 80.1' 15 3 . 7 23 7 . 7 80.1 18'24'18'24' R2 0 ' R5' R5' R5 ' R5 ' R20' R5 ' R5' R64 ' R19 9 ' R26 1 ' R12' R1 5 ' R15 ' R1 5 ' R5 ' R4 ' R4' 5' 6' 26' R4' R5' R4 ' 845 SE ESKER RIDGE DRIVE 915 SE ESKER RIDGE DRIVE 9.5'9' 9.5'9' 9.5 ' 9' 9.5 ' 9' 1B BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m ED C LJ M LM W 12 - 0 9 - 2 5 30 ' 12 5 . 1 3 9 6 . 0 1 C2 0 0 125.1396.01 C200 CA L I B E R K E T T L E S T O N E P L A T 1 DI M E N S I O N P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 12 - 2 3 - 2 5 01 - 0 6 - 2 6 01 - 2 0 - 2 6 02 - 0 3 - 2 6 LJ M LJ M LJ M LJ M 1234 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 5 \ 1 2 5 . 1 3 9 6 . 0 1 0 \ C A D D \ S P _ 1 2 5 1 3 9 6 _ D I M . d w g LO G A N M Y E R S , DI M E N S I O N P L A N , 20 2 6 / 0 2 / 0 3 , 2: 2 4 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 30 DIMENSION PLAN CONSTRUCTION NOTES 1. PROTECT ALL SITE FEATURES NOT SCHEDULED FOR DEMOLITION OR MODIFICATION. ANY DAMAGES TO ITEMS NOT SHOWN FOR REMOVAL SHALL BE REPAIRED BY THE CONTRACTOR TO THE OWNERS SPECIFICATIONS WITHOUT ADDITIONAL COMPENSATION. A.EXISTING UTILITIES. COORDINATE ANY NECESSARY RELOCATIONS OR ADJUSTMENTS WITH THE OWNER AND UTILITY PROVIDER PRIOR TO CONSTRUCTION. ADJUSTMENTS OF UTILITY APPURTENANCE TO FINISH GRADE IS CONSIDERED INCIDENTAL TO THE PROJECT. B.EXISTING PAVEMENTS TO REMAIN. 2. DEMOLITION. REMOVE AND DISPOSE OF THE FOLLOWING EXISTING ITEMS: A.ADJUST MANHOLE TO GRADE. SEE UTILITY PLAN FOR MORE INFORMATION. B.CONTRACTOR TO LOCATE AND ADJUST ELECTRIC AND FIBER LINE AS NECESSARY. COORDINATE WITH FRANCHISE UTILITY PROVIDER FOR ANY ADJUSTMENTS PRIOR TO CONSTRUCTION. 3. PAVEMENTS, PROVIDE THE FOLLOWING: A.6" DEPTH PCC PAVEMENT ON 12" DEPTH PREPARED SUBGRADE COMPACTED TO 95% STANDARD PROCTOR DENSITY. (C4 PCC MIX). B.4" DEPTH PCC SIDEWALK ON 6" DEPTH PREPARED SUBGRADE COMPACTED TO 95% STANDARD PROCTOR DENSITY. PROVIDE 6" DEPTH PCC RAMP AT DRIVEWAY ENTRANCES. C.CONNECT TO EXISTING PAVEMENTS. D.6" STANDARD CURB. E.PEDESTRIAN RAMP WITH A MAXIMUM SLOPE OF 8.33%. PROVIDE DETECTABLE WARNING SYSTEM AT RAMPS WHERE PEDESTRIAN TRAFFIC MEETS VEHICULAR TRAFFIC. 6" DEPTH PCC RAMP. F.6" DEPTH PCC TRAIL. CONNECT TO EXISTING AT NEAREST JOINT. G.ADA ACCESSIBLE RAMP AT 8.33% MAXIMUM SLOPE. TAPER FROM 6" INTEGRAL CURB TO NO CURB. 6" DEPTH PCC RAMP. H.6" INTEGRAL SIDEWALK AND CURB. I.PRECAST PCC PARKING BARRIER. J.4' X 4' CLUSTER MAILBOX PAD. K.PCC STAIRS W/ RAILING. L.7" DEPTH PCC PAVEMENT ON 12" DEPTH PREPARED SUBGRADE COMPACTED TO 95% STANDARD PROCTOR DENSITY. (C4 PCC MIX). 4. PAVEMENT MARKINGS PROVIDE THE FOLLOWING: A.4" WIDE PAINTED PARKING STALL LINES, COLOR AS PER OWNER. B.PAINTED STATE OF IOWA APPROVED ACCESSIBLE SYMBOL. C.45° STRIPING AT 3' ON CENTER SPACING WHERE SHOWN. 5. ACCESSIBLE PARKING SIGNAGE: A.PROVIDE SIGN WITH VAN ACCESSIBLE SYMBOL AS PER "ADAAG" STANDARDS. 6. SITE AMENITIES, PROVIDE THE FOLLOWING: A.TRASH ENCLOSURE WITH 7" PCC PAD. SEE ARCHITECTURAL PLANS FOR DETAILS. B.TRANSFORMER LOCATION. 7. SEE ARCHITECTURAL AND STRUCTURAL PLANS FOR DETAILED BUILDING CONSTRUCTION INFORMATION. CURVE TABLE CURVE NO. C1 M C2 M C3 M C4 M C5 M Δ 11°29'52" 7°30'35" 78°38'08" 21°42'40" 59°58'38" RADIUS 1065.00' 535.00' 25.00' 935.00' 246.00' ARC LENGTH 213.72' 70.12' 34.31' 354.30' 257.51' TANGENT 107.22' 35.11' 20.48' 179.30' 141.96' CHORD BEARING/LENGTH N52°50'50"W 213.36' N50°44'56"W 70.07' N15°02'44"W 31.68' N13°16'38"E 352.19' S31°28'30"E 245.92' C1 P 11°29'52"1065.00'213.72'-N53°04'39"W 213.36' C2 P 7°30'09"535.00'70.06'-- C3 P 78°44'20"25.00'34.36'-- C4 P 21°42'48"935.00'354.34'-- C5 P 59°58'54"246.00'257.53'-- C6 38°08'08"230.00'153.09'79.50'N44°00'37"W 150.28' PAVEMENT LEGEND 4" PCC SIDEWALK 6" PCC PAVEMENT 7" PCC PAVEMENT 10 15 3 7 11 6 12 14 8 11 12 9 10 14 9 TRASH 9 42-PLEX 33,993 SF 66-PLEX 53,970 SF T T Outlot 'U' The Shops At Kettlestone North Plat 1 (Bk 2017, Pg 3256) 91,225 SF 2.09 AC LOT 1 Existing 30' Storm Sewer Easement (Book 2017, Page 3266) Existing 62' Public Ingress/Egress Easement (Book 2019, Page 10433) INGRESS/EGRESS EASEMENT (WIDTH VARIES) INGRESS/EGRESS EASEMENT (TO BE RECORDED IN SEPARATE DOCUMENT) TRAS H UP 51 0 5 S F FU T U R E R E S T A U R A N T 10 9 489 S F EN T R Y 102 218 S F WO M E N 10 4 15 7 S F ME N10 3 38 S F UT I L . 11 0 VE N T CH A S E AB O V E SE R V I C E E N T R Y D3 D10 D1 6 D7 13 6 S F VE S T I B U L E 10 1 74 S F VE S T I B U L E 108D4 D1 D9D6 FLO O R / R O O F A B O V E FL O O R / R O O F A B O V E RO O F A B O V E RO O F A B O V E FLOO R / R O O F A B O V E ROOF A B O V E RO O F A B O V E D15 D17 D18 D18 D18 D18 D17 D3 D1 6 D14 PROP O S E D BUILD I N G 10,84 3 S F FFE= 1 0 4 1 . 9 0 49,530 SF 1.14 AC LOT 1 73,073 SF 1.68 AC LOT 2 1 3 100 BM501 Intake=1041.68 F.L.=1035.71 15" RCP NE Rim=1041.74 F.L.=1031.62 24" RCP S F.L.=1031.47 24" RCP N Rim=1039.67 Intake=1038.97 F.L.=1034.49 15" RCP W F.L.=1034.42 15" RCP N Intake=1039.04 F.L.=1035.04 15" RCP E Rim=1036.13 F.L.=1031.61 15" RCP N F.L.=1031.58 15" RCP S Intake=1031.74 F.L.=1026.94 24" RCP SE F.L.=1026.74 24" RCP N Intake=1032.82 F.L.=1028.25 12" RCP W Intake=1032.62 F.L.=1027.60 12" RCP E F.L.=1027.60 24" RCP NW Intake=1034.99 F.L.=1028.84 24" RCP E F.L.=1028.81 36" RCP NE F.L.=1028.69 30" RCP SW Intake=1034.99 F.L.=1029.79 24" RCP S F.L.=1029.45 30" RCP NE Rim=1037.54 Inv=1023.91 8" TRUSS N Difficult To Determine Pipe Size Storm C/O Rim=1035.00 SEESKERRIDGEDRIVE CON C R E T E GRA V E L CO N C R E T E S I D E W A L K CO N C R E T E S I D E W A L K SE PARKVIEW CROSSING DRIVE CO N C R E T E CONCRETE CONCRETE SIDEWALK CONCRETE CO N C R E T E CO N C R E T E S I D E W A L K CON C R E T E S I D E W A L K SEENCOMPASSDRIVE Intake=1041.70 F.L.=1036.07 15" RCP SW FIL L P I L E ST-2, 10'' NYLOPLAST DRAIN BASIN W/ DOMED GRATE RIM: 1042.50 INV: 1038.50 (OUT E) ST-9, 8'' NYLOPLAST DRAIN BASIN W/ DOMED GRATE RIM: 1042.25 INV: 1038.75 (OUT N) ST-9A, 8'' NYLOPLAST DRAIN BASIN W/ SOLID LID RIM: 1041.06 INV: 1035.56 (IN S) INV: 1035.46 (OUT N) ST-1, INTAKE, SW-501 T/C: 1041.05 INV: 1037.05 (OUT NW) ST-3, INTAKE, SW-501 T/C: 1040.95 INV: 1036.50 (IN SE) INV: 1037.30 (IN W) INV: 1036.40 (OUT N) ST-7A, MANHOLE, SW-401 (48'') RIM: 1039.98 INV: 1033.45 (IN SW) INV: 1033.74 (IN E) INV: 1033.10 (OUT N) ST-4, INTAKE, SW-511 RIM: 1039.90 INV: 1035.62 (IN S) INV: 1035.50 (OUT NE) ST-5, INTAKE, SW-511 RIM: 1039.65 INV: 1034.31 (IN SW) INV: 1034.21 (OUT NE) ST-7, INTAKE, SW-501 T/C: 1038.95 INV: 1034.40 (IN SE) INV: 1034.30 (OUT W) ST-6, INTAKE, SW-501 T/C: 1037.73 INV: 1034.75 (OUT NW) ST-10A, 30'' NYLOPLAST DRAIN BASIN RIM: 1036.70 INV: 1029.50 (IN W) SUMP=1027.50 ST-10, INTAKE, SW-501 T/C: 1036.30 INV: 1032.19 (IN S) INV: 1030.63 (OUT E) ST-8, INTAKE, SW-501 T/C: 1035.25 INV: 1029.60 (OUT W) ST-12, 30'' NYLOPLAST DRAIN BASIN (SEE DETAIL 5 ON SHEET C600) RIM: 1035.04 INV: 1028.25 (OUT E) ST-8A, 30'' NYLOPLAST DRAIN BASIN RIM: 1034.95 INV: 1029.50 (IN E) SUMP=1027.50 INV: 1029.50 (IN S) SUMP=1027.50 ST-11, INTAKE, SW-501 T/C: 1034.75 INV: 1029.56 (OUT W) SUMP=1027.50 CONNECT TO EXISTING INTAKE INV: 1027.72 111 L F O F 1 2 " H D P E @ 0 . 5 0 % 78 L F O F 1 2 " H D P E @ 1 . 0 0 % 10 8 L F O F 1 8 " H D P E @ 1 . 1 0 % 69 L F O F 1 2 " H D P E @ 0 . 5 0 % 58 LF OF 18" HDPE @ 1.30% 56 LF OF 12" HDPE @ 1.00% 6 LF OF 12" HDPE @ 1.00% 10 LF OF 12" HDPE @ 1.00% 31 LF OF 18" RCP @ 1.70% 16 4 L F O F 1 8 " H D P E @ 2 . 2 0 % 56 LF OF 12" HDPE @ 2.00% 121 LF OF 6" HDPE @ 0.99% 16 0 L F O F 6 " H D P E @ 2 . 0 0 % 13 1 L F O F 6 " H D P E @ 2 . 5 0 % 1A 1A 1A 1A 7 7 2A 2H 2A 2K 2D 6 4 4 2E 2E 2E 2F 2G 2C 2B 2B CLEANOUT RIM: 1043.34 INV: 1035.50 (OUT NE) MANHOLE, SW-301 RIM: 1041.50 INV: 1034.65 (IN SW) INV: 1032.90 (OUT NW) INV: 1034.75 CONNECT TO EXISTING MANHOLE ADJUSTED RIM: 1036.35 INV: 1025.00 (IN SE) INV: 1023.91 (OUT N) INV: 1031.92 3 LF OF 6" SANITARY SEWER @ 3.50% 31 6 L F O F 8 " S A N I T A R Y S E W E R @ 2 . 5 0 % 45 LF OF 6" SANITARY SEWER @ 5.00% BP:1030.05 (ST) TP: 1026.77 (SAN) BP:1033.73 (ST) TP: 1031.75 (SAN) BP:1033.61 (ST) TP: 1032.11 WAT BP:1032.34 (ST) TP: 1030.84 WAT 2H BP: 1034.75 WAT TP: 1029.57(SAN) 2A 3 3 EXISTI N G 1 5 0 ' H Y D R A N T C O V E R A G E 1 5 0 ' H Y D R A N T C O V E R A G E 3 3 3 1:1 RISER 2J BP: 1034.81 WAT TP: 1033.25(SAN) 3 2I PROVIDE FLEXSTORM FFE=1041.75 FFE=1043.50 BP: 1034.90 WAT TP: 1033.33(SAN) 3 5 5 4A 4A 4A 4A 4A BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m ED C LJ M LM W 12 - 0 9 - 2 5 30 ' 12 5 . 1 3 9 6 . 0 1 C3 0 0 125.1396.01 C300 CA L I B E R K E T T L E S T O N E P L A T 1 UT I L I T Y P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 12 - 2 3 - 2 5 01 - 0 6 - 2 6 01 - 2 0 - 2 6 02 - 0 3 - 2 6 LJ M LJ M LJ M LJ M 1234 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 5 \ 1 2 5 . 1 3 9 6 . 0 1 0 \ C A D D \ S P _ 1 2 5 1 3 9 6 _ U T I L . d w g LO G A N M Y E R S , UT I L I T Y P L A N , 20 2 6 / 0 2 / 0 3 , 2: 2 4 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 30 UTILITY PLAN CONSTRUCTION NOTES 1. PROTECT ALL SITE FEATURES NOT SCHEDULED FOR DEMOLITION OR MODIFICATION. ANY DAMAGES TO ITEMS NOT SHOWN FOR REMOVAL SHALL BE REPAIRED BY THE CONTRACTOR TO THE OWNERS SPECIFICATIONS WITHOUT ADDITIONAL COMPENSATION. A.EXISTING UTILITIES. COORDINATE ANY NECESSARY RELOCATIONS OR ADJUSTMENTS WITH THE OWNER AND UTILITY PROVIDER PRIOR TO CONSTRUCTION. ADJUSTMENTS OF UTILITY APPURTENANCE TO FINISH GRADE IS CONSIDERED INCIDENTAL TO THE PROJECT. 2. WATER SERVICES, PROVIDE THE FOLLOWING: A.6" WATER SERVICE LINE. B.BUILDING WATER FIRE SERVICE CONNECTION. VERIFY LOCATION AND DEPTH WITH MECHANICAL PLANS PRIOR TO CONSTRUCTION. C.CONNECT TO EXISTING WATER SERVICE. CONTRACTOR TO VERIFY LOCATION AND DEPTH PRIOR TO CONSTRUCTION. REMOVE & RELOCATE HYDRANT ASSEMBLY. D.2" DOMESTIC LINE WITH VALVE. E.WATER BEND. F.8" X 8" WATER CROSS W/ 6" REDUCERS. G.RELOCATED HYDRANT ASSEMBLY. H.8" WATER SERVICE LINE. I.6" X 6" WATER TEE. J.HYDRANT ASSEMBLY. K.4" DOMESTIC LINE WITH VALVE. 3. CRITICAL CROSSING. CONTRACTOR TO VERIFY ALL CROSSINGS AND PROVIDE 18" MINIMUM SEPARATION. 4. COORDINATE ELECTRICAL SERVICES AND METER LOCATION WITH UTILITY SERVICE PROVIDER PRIOR TO CONSTRUCTION. SEE ARCHITECTURAL AND MECHANICAL PLANS FOR INTERIOR UTILITY ROUTING, METERS, DESIGN INFORMATION AND COORDINATE UTILITY CONNECTIONS ACCORDINGLY. A.LIGHT POLE LOCATION. REFER TO PHOTOMETRIC PLAN FOR DETAILS. 5. ROOF DRAIN LOCATION. SEE ARCHITECTURAL PLANS FOR DETAILS. 6. SEE SHEET C600-C601 FOR UNDERGROUND DETENTION DETAILS. 7. UTILITY ROOM. SEE ARCHITECTURAL PLANS AND MECHANICAL PLANS FOR RISER LOCATION. A. NOTIFY THE CITY OF WAUKEE AT LEAST 48 HRS PRIOR TO CONNECTING TO ANY PUBLIC UTILITY. B. ALL UTILITIES SHALL BE TESTED TO THE CITY OF WAUKEE STANDARD SPECIFICATION FOR PUBLIC IMPROVEMENTS AND ANY TESTING OR TIE-INS SHALL BE WITNESSED BY THE CITY OF WAUKEE ENGINEERING DEPARTMENT. C. ALL SANITARY SEWER AND STORM SEWER SHALL BE CLEANED AND TELEVISED PRIOR TO PAVING. THE CITY OF WAUKEE SHALL WITNESS ALL CLEANING AND TELEVISING. COPIES OF THE REPORT AND VIDEO SHALL BE PROVIDED TO THE CITY OF WAUKEE. ALL SANITARY SEWER MANHOLES SHALL BE VACUUM TESTED. D. ALL WATERMAIN SHALL BE PRESSURE AND BACTERIA TESTED AND DECHLORINATED. GENERAL CONSTRUCTION NOTES 10 15 3 7 11 6 12 14 8 11 12 9 10 14 9 TRASH 9 42-PLEX 33,993 SF 66-PLEX 53,970 SF T T S2 6 ° 5 5 ' 1 9 " W 3 2 2 . 7 1 ' M S2 6 ° 4 1 ' 3 0 " W 3 2 2 . 7 1 ' P Outlot 'U' The Shops At Kettlestone North Plat 1 (Bk 2017, Pg 3256) 91,225 SF 2.09 AC LOT 1 N61° 2 8 ' 1 3 " W 3 0 2 . 5 8 ' M N61° 4 2 ' 0 2 " W 3 0 2 . 5 8 ' P C1 C3 Existing 30' Storm Sewer Easement (Book 2017, Page 3266) Existing 62' Public Ingress/Egress Easement (Book 2019, Page 10433) INGRESS/EGRESS EASEMENT (WIDTH VARIES) INGRESS/EGRESS EASEMENT (TO BE RECORDED IN SEPARATE DOCUMENT) TRAS H 14 16 18 8 9 16 12 411 10 7 2 UP UP 51 0 5 S F FU T U R E R E S T A U R A N T 109 489 S F EN T R Y 10 2 218 S F WO M E N 10 4 15 7 S F ME N10 3 38 S F UT I L . 11 0 VE N T CH A S E AB O V E SE R V I C E E N T R Y D3 D1 0 D16 D7 13 6 S F VE S T I B U L E 101 74 S F VE S T I B U L E 108D4 D1 D9D6 FLO O R / R O O F A B O V E FL O O R / R O O F A B O V E RO O F A B O V E RO O F A B O V E FLOO R / R O O F A B O V E ROOF A B O V E RO O F A B O V E D1 5 D17 D18 D18 D18 D18 D1 7 D3 D1 6 D1 4 PROP O S E D BUILD I N G 10,84 3 S F FFE= 1 0 4 1 . 9 0 49,530 SF 1.14 AC LOT 1 73,073 SF 1.68 AC LOT 2 1 3 100 BM501 Intake=1041.68 F.L.=1035.71 15" RCP NE Rim=1041.74 F.L.=1031.62 24" RCP S F.L.=1031.47 24" RCP N Rim=1039.67 Intake=1038.97 F.L.=1034.49 15" RCP W F.L.=1034.42 15" RCP N Intake=1039.04 F.L.=1035.04 15" RCP E Rim=1036.13 F.L.=1031.61 15" RCP N F.L.=1031.58 15" RCP S Intake=1031.74 F.L.=1026.94 24" RCP SE F.L.=1026.74 24" RCP N Intake=1032.82 F.L.=1028.25 12" RCP W Intake=1032.62 F.L.=1027.60 12" RCP E F.L.=1027.60 24" RCP NW Intake=1034.99 F.L.=1028.84 24" RCP E F.L.=1028.81 36" RCP NE F.L.=1028.69 30" RCP SW Intake=1034.99 F.L.=1029.79 24" RCP S F.L.=1029.45 30" RCP NE Rim=1037.54 Inv=1023.91 8" TRUSS N Difficult To Determine Pipe Size Storm C/O Rim=1035.00 SEESKERRIDGEDRIVE CON C R E T E GRA V E L CO N C R E T E S I D E W A L K CO N C R E T E S I D E W A L K SE PARKVIEW CROSSING DRIVE CO N C R E T E CONCRETE CONCRETE SIDEWALK CONCRETE CO N C R E T E CO N C R E T E S I D E W A L K CON C R E T E S I D E W A L K SEENCOMPASSDRIVE 10 4 4 104 3 104 2 1041 1040 103 9 10 3 8 103 6 103 7 103 9 104 0 104 1 104 2 104 3 104 4 1045 104 6 1047 1048 1049 1049 1048 1047 1046 1045 1038 10 4 1 10 4 1 103 8 10 4 2 10 4 3 10 4 4 10 4 4 10 4 3 10 4 2 10 4 1 104 0 10 3 9 103 8 103 7 1034 10 3 5 103 61037 1038 10 3 9 1040 1043 10 4 1 103 7 103 6 10 3 5 10 3 4 10 3 3 1032 10 3 410 3 5 10 3 6 Intake=1041.70 F.L.=1036.07 15" RCP SW 10 3 9 10 3 7FIL L P I L E 1040 1036 1037 1038 1039 10 4 0 1040 1036 10 3 7 1037 10 3 8 1038 10 3 9 1039 10 3 9 1039 1040 10 4 0 10 4 1 10 4 1 1041 1041 10 4 1 1041 104 3104 4 104 3104 4 10 4 3 10 4 3 10 4 2 10 4 3 FFE=1043.50 FFE=1041.75 10 4 2 10 4 3 1040 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●●●●● SILT FENCE TYP SILT FENCE TYP SILT FENCE TYP SILT FENCE TYP SILT FENCE TYP SILT FENCE TYP TOPSOIL STOCKPILE STABALIZED CONSTRUCTION ENTRANCE CONCRETE WASHOUT STAGING AREA PORTABLE TOILET LIMITS OF DISTURBANCE UNDERGROUND DETENTION (POST CONSTRUCTION FACILITY) ST-12 POST-CONSTRUCTION FACILITY ● ● ● ● ● ● ● ● ● INLET PROTECTION TYP ULTIMATE DISCHARGE TO FOX CREEK SILT FENCE TYP INLET PROTECTION TYP BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m ED C LJ M LM W 12 - 0 9 - 2 5 30 ' 12 5 . 1 3 9 6 . 0 1 C4 0 0 125.1396.01 C400 CA L I B E R K E T T L E S T O N E P L A T 1 GR A D I N G A N D E R O S I O N C O N T R O L P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 12 - 2 3 - 2 5 01 - 0 6 - 2 6 01 - 2 0 - 2 6 02 - 0 3 - 2 6 LJ M LJ M LJ M LJ M 1234 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 5 \ 1 2 5 . 1 3 9 6 . 0 1 0 \ C A D D \ S P _ 1 2 5 1 3 9 6 _ E R O S . d w g LO G A N M Y E R S , GR A D I N G A N D E R O S I O N C O N T R O L P L A N , 20 2 6 / 0 2 / 0 3 , 2: 2 4 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 30 SUDAS TYPE 4 SEEDING, FERTILIZING & MULCHING 2.83 AC. SILT FENCE 1,045 LF INLET PROTECTION 10 EA DISTURBED AREA 2.83 AC. SOD 0.76 AC. 1.UTILITY WARNING: THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR RECORDS OBTAINED. THE SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEY FURTHER DOES NOT WARRANT THAT THE UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED. 2.NOTIFY UTILITY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXISTENCE, EXACT LOCATION AND DEPTH OF ALL UTILITIES. AVOID DAMAGE TO UTILITIES AND SERVICES DURING CONSTRUCTION. ANY DAMAGE DUE TO THE CONTRACTOR'S CARELESSNESS SHALL BE CORRECTED AT THE CONTRACTOR'S EXPENSE. COORDINATE ANY UTILITY RELOCATIONS WITH UTILITY PROVIDER. 3.ALL PROPOSED CONTOURS AND SPOT ELEVATIONS SHOWN ARE FINISHED GRADES AND/OR TOP OF PAVING SLAB (GUTTER), UNLESS OTHERWISE NOTED. 4.CONTRACTOR TO STRIP AND STOCKPILE TOPSOIL FROM ALL AREAS TO BE CUT OR FILLED. RESPREAD TO MINIMUM 8" DEPTH TO FINISH GRADES. 5.THE CONTRACTOR IS RESPONSIBLE FOR CLEANING DIRT AND DEBRIS FROM STREETS, DRIVEWAYS AND SIDEWALKS CAUSED BY CONSTRUCTION ACTIVITIES BY THE END OF THE WORK DAY AND PRIOR TO A RAIN EVENT. 6.SLOPES OF ALL UNPAVED AREAS TO BE 2.0% MINIMUM. 7.CONTRACTOR TO CONTAIN SAWCUTTING/GRINDING SLURRY ON SITE AND DISPOSE OF ACCORDING TO IOWA DNR GENERAL PERMIT NO. 2 8.PROVIDE SEDIMENT BASKETS AT ALL INTAKES. 9.PROVIDE SILT FENCE WHERE SHOWN AND AS DETAILED ON THIS SHEET. MAINTAIN AND ADJUST SILT FENCE AS NECESSARY DURING CONSTRUCTION. GRADING NOTES TYPICAL SILT FENCE INSTALLATION ON LONGITUDINAL SLOPES (Profile View) FLOW 'T ' S T E E L FE N C E P O S T 4' - 0 " M I N SEE PLANS FOR SPACING TYPICAL SILT FENCE INSTALLATION ON LONGITUDINAL SLOPES (Plan View) DETAILS OF SILT FENCE ON LONGITUDINAL SLOPES ATTACHMENT TO POST 200'-0" MAX LENGTH PER SECTION 600'-0" IF SLOPE IS FLATTER THAN 5% 36 " 24 " 8'-0" SPACING TYPICAL SILT FENCE DITCH CHECK BAC K S L O P E FORE S L O P E VARIABLE (20'-0" FOR A NORMAL 10'-0" WIDE DITCH) POST SPACING (5'-0" MAX) POST SPACING 5'-0" MAX) 2" MI N 20 " M I N 1 1 2 GROUND LINE FABRIC GROUND CONTOURS INSTALL "J-HOOK" AT EACH END OF AN INDIVIDUAL SECTION OF SILT FENCE INSTALL PARALLEL TO GROUND CONTOUR FABRICGROUND LINE FABRIC POST WIRE OR CABLE TIES 2 2 1 C400 SILT FENCE DETAIL NO SCALE 1 INSERT 12 INCHES OF FABRIC A MINIMUM OF 6 INCHES DEEP (FABRIC MAY BE FOLDED BELOW THE GROUND LINE. 2 REDUCE POST SPACING TO 5'-0" AT WATER CONCENTRATION AREAS, OR AS REQUIRED TO ADEQUATELY SUPPORT FENCE. QUANTITIES T T Ex i s t i n g 3 0 ' S t o r m S e w e r E a s e m e n t IN G R E S S / E G R E S S E A S E M E N T (W I D T H V A R I E S ) IN G R E S S / E G R E S S E A S E M E N T (T O B E R E C O R D E D I N S E P A R A T E D O C U M E N T ) 49,530 SF 1.14 AC LOT 1 73,073 SF 1.68 AC LOT 2 BM 5 0 1 SEESKERRIDGEDRIVE SE PARKVIEW CROSSING DRIVE SEENCOMPASSDRIVE 1044 104 3 104 2 10 4 1 10 4 0 103 9 1038 103 6 103 7 103 9 104 0 104 1 104 2 104 3 104 4 104 5 10 4 6 10 4 7 10 4 8 10 4 9 10 4 9 10 4 8 10 4 7 10 4 6 10 4 5 10 3 8 1041 1041 103 8 1042 1043 1044 1044 1043 1042 1041 1040 1039 103 8 103 7 10 3 4 1035 103 6 10 3 7 10 3 8 1039 10 4 0 10 4 3 1041 103 7 103 6 1035 1034 1033 10 3 2 1034 1035 1036 1039 1037 -3: 1 -3 : 1 -3 : 1 OV E R F L O W OVER F L O W OVER F L O W OVER F L O W OVER F L O W OV E R F L O W OVERFLOW OVERFLOW OVERFLOW ULTIMATE DISCHARGE TO FOX CREEK 5.0% 4.1% 4.0% 2.3 % 2.0% 2.0% 11.9 % OV E R F L O W OVER F L O W 100-YEAR ELEV:1040.65 100-YEAR ELEV:1040.56 100-YEAR ELEV:1037.85 100-YEAR ELEV:1038.51 100-YEAR ELEV:1034.98 100-YEAR ELEV:1034.54 100-YEAR ELEV:1035.83 10 3 5 10 4 0 10 4 0 10 3 6 10 3 6 10 3 7 10 3 7 10 3 8 10 3 8 10 3 9 10 3 9 1037 1038 1039 10 3 9 1039 10 3 9 1040 10 4 0 1040 104 0 10 4 1 1041 1040 10 4 1 10 4 1 104 2 1043 104 4 10421043 1042 1043 10 4 2 10 4 3 10 4 1 10421043 1043 1044 104 5 104 3 10 4 3 104 4 100-YEAR ELEV:1040.25 100-YEAR ELEV:1040.09 100-YEAR ELEV:1042.56 100-YEAR ELEV:1042.83 4.2 % 1.8% 0.7% 1.5% 1.6% 1.6% 1.1 % 1041.60 TC 1041.10 G 1041 . 0 5 T C 1040 . 5 5 G (1041.00) (1041.51) (1041.68) (1040.51) 1041.30 TC 1040.80 G 1041.48 TC 1040.98 G 104 1 . 5 7 T C 104 1 . 0 7 G 1042.60 TC 1042.10 G 1042.10 TC 1041.60 G 1042.01 TC 1041.51 G 1042.10 TC 1041.60 G 1040.80 1041.80 1041.28 10 4 1 . 3 3 10 4 1 . 4 2 10 4 2 . 0 4 1041. 6 2 104 1 . 8 3 104 1 . 8 4 104 1 . 9 0 104 2 . 3 5 1041.55 1042.10 10 4 1 . 7 5 1041.20 1042.00 1041 . 4 0 T C 1040 . 9 0 G 1041 . 9 0 T C 1041 . 4 0 G 1041 . 1 0 T C 1040 . 6 0 G 1041 . 6 5 T C 1041 . 1 5 G 10 4 1 . 7 0 10 4 1 . 6 5 1041.29 1041.35 1041.67 1041.22 1041.33 1041.58 1041.40 1040.70 1041.07 1040.13 1039.34 1040.60 1040. 4 5 1041 . 2 7 104 1 . 2 4 1041.15 TC 1040.65 G 1040.60 TC 1040.10 G 1041 . 1 5 T C 1040 . 6 5 G 1041.05 TC 1040.55 G 1040 . 5 5 T C 1040 . 0 5 G 1041. 3 7 T C 1040. 8 7 G 1040.60 TC 1040.10 G 1040.87 TC 1040.37 G 1041 . 0 0 T C 1040 . 5 0 G 1040.03 TC 1039.53 G 1039.20 TC 1038.70 G (1040.17) (1039.41) (1038.00) (1038.80) (1039.76) (1039.86) 1039. 9 0 1040. 4 6 1039. 6 5 1040. 1 5 1040. 6 5 1041.21 1041.11 1040.30 1040.85 1042 . 0 0 T C 1041 . 5 0 G 1041.28 1040.70 1041.25 1041.15 1040.53 1041.75 1041.75 1041.25 1041.25 1040.89 1040.81 1038.60 TC 1038.10 G 1040.65 TC 1040.15 G 1039.90 TC 1039.40 G 1037.75 TC 1037.25 G 1039.17 TC 1038.67 G 1038.95 TC 1038.45 G 1039.86 TC 1039.36 G 1039. 8 2 T C 1039. 3 2 G 1038.63 TC 1038.13 G 1036.89 TC 1036.39 G 1035.25 TC 1034.75 G 1038. 1 7 1037. 6 3 1040.08 1039.45 1038.93 10 3 9 . 1 2 1039 . 5 2 1039 . 9 5 1039 . 8 0 1038 . 0 9 1036 . 7 7 1035.04 103 9 . 5 8 104 0 . 6 0 1038 . 7 3 1039 . 2 5 1040.40 1039 . 9 5 1036 . 1 5 1036 . 2 5 1036 . 4 7 1036.70 1040.45 TC 1039.95 G 1041.60 TC 1041.10 G 1041.10 TC 1040.60 G 1040 . 9 1 1041 . 0 1 (104 0 . 3 2 ) (104 0 . 4 3 ) 1041 . 2 0 1041 . 7 0 1041 . 7 0 1040 . 5 5 1041.55 TC 1041.05 G 1040.45 TC 1039.95 G 1036.40 TC 1035.90 G 1034.80 TC 1034.30 G 1034.75 TC 1034.25 G (103 5 . 3 3 ) (103 5 . 6 8 ) 1040.10 TC 1039.60 G 1036.40 TC 1035.90 G 1036.30 TC 1035.80 G 10 4 1 . 1 6 1042.17 1042.32 1043.10 1043.25 1043.70 1043.85 1044.41 1044.56 1044.72 1044.67 1042.4 41042.3 9 1042.8 41042.7 9 104 2 . 5 0 104 2 . 9 0 FFE=104 3 . 5 0 FFE=1041.75 104 0 . 9 5 T C 104 0 . 4 5 G 1043.10 104 2 . 5 0 1043.2 5 1042.2 5 1043.2 5 1037.73 TC 1037.23 G 10 4 2 . 0 0 1043 . 5 0 1042.25 1043 . 5 0 10 4 0 . 7 5 1041.75 10 4 1 . 7 5 1041.75 1039.39 TC 1038.89 G 1035.29 TC 1034.79 G 1041.35 104 1 . 3 0 T C 104 0 . 8 0 G 104 2 . 3 0 1042.20 TC 1041.70 G 1044.47 1041.75 (1037.54) (1036.43) (1035.92) (1037.30) 1038.74 TC 1038.24 G (1035.76) (1041.73) (1044.72) 104 5 . 1 8 1035 . 5 2 (103 2 . 9 9 ) (103 7 . 1 9 ) (1036.38) (1036.44) 1034.95 1039.98 1.4% 1040 . 2 2 (1036.68) 10 4 1 . 3 7 BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m ED C LJ M LM W 12 - 0 9 - 2 5 20 ' 12 5 . 1 3 9 6 . 0 1 C4 0 1 125.1396.01 C401 CA L I B E R K E T T L E S T O N E P L A T 1 DE T A I L E D G R A D I N G P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 12 - 2 3 - 2 5 01 - 0 6 - 2 6 01 - 2 0 - 2 6 02 - 0 3 - 2 6 LJ M LJ M LJ M LJ M 1234 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 5 \ 1 2 5 . 1 3 9 6 . 0 1 0 \ C A D D \ S P _ 1 2 5 1 3 9 6 _ G R D G . d w g LO G A N M Y E R S , DE T A I L E D G R A D I N G P L A N , 20 2 6 / 0 2 / 0 3 , 2: 2 5 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 20 1042.20 TC 1041.70 G 1041 . 4 1 1041.5 0 1041.4 2 1041.3 3 1041.2 4 1041.1 4 1041 . 7 1 1041 . 6 3 1041 . 5 4 104 1 . 8 0 10 4 1 . 6 4 10 4 1 . 8 5 1041 . 8 8 104 1 . 9 0 104 2 . 3 5 1043.15 1043.15 1043.10 1043.05 1043.05BS 1043.10BS 1044.55TS 1044.60TS 1044.65 1044.65 1044.93 1044.89 1043.50 1043.50 1040 . 7 5 104 0 . 8 3 10 4 0 . 4 5 10 4 1 . 1 5 104 1 . 0 8 104 1 . 1 3 10 4 1 . 2 0 10 4 1 . 2 7 104 1 . 1 9 10 4 0 . 6 4 T C 10 4 0 . 1 4 G 1041.28 10 4 4 . 4 1 10 4 4 . 5 6 10 4 2 . 4 4 10 4 2 . 3 9 10 4 2 . 8 4 10 4 2 . 7 9 104 2 . 5 0 104 2 . 9 0 104 2 . 5 0 10 4 2 . 2 5 10 4 1 . 7 5 C2 N88°07'26"E 49.03' 10 4 4 10 4 4 3.2 % 1.4 % 0.0% 0.9% 104 1 . 1 3 T C 104 0 . 6 3 G 10 4 2 . 0 4 104 2 . 3 0 1042. 2 5 T C 1041. 7 5 G 1041 . 7 4 1041 . 9 4 T C 1041 . 4 4 G 104 1 . 2 4 3.2 % 1044.74 1044.78 1.4 % 1.0 % 1.5 % FFE=1043.50 LOT 2 3.2 % 0.0% 4.1 % 1.5% 1.6% 1.6% 1.6% 1.6% 1.6% 1. 2 % 0. 9 % 0.9 % 1.0 % 1.0 % 6. 9 % 1.7% 4.5 % 1.7% 1.7% 2.0% 1.8% 1.7% 1.8% 5.1% 5.6% 1.0%1.0% 1. 5 % 1. 5 % 1. 5 % 1.0%1.0% 7. 5 % 0. 7 % 0. 6 % 0. 7 % 0. 7 % 0. 7 % 0.9 % 0.9 % 0. 7 % 4.5 % 1. 5 % 1.5% 0. 7 % 0. 7 % 1.0% 2.0 % 1.0 % 1.0% 0.2% 0. 7 % 0. 8 % 1041.70 1041.70 1041.70BS1041.70BS 1043.20TS1043.20TS 1043.221043.25 1043.5 0 1043.5 0 10 4 0 . 4 0 10 3 9 . 9 5 10 4 1 . 6 0 T C 10 4 1 . 1 0 G 10 4 1 . 2 0 10 4 3 . 5 0 FFE=1043.50 1.2% 0.0% 1. 7 % 1. 7 % 0. 3 % 3.8 % 1043.44 1043.44 1.5 % 1043.40 1043.40 1043.35 1043.35 1043.50 1043.50 1.5 % 1.0 % 1.0 % 1041.10 TC 1040.60 G 10 4 1 . 6 0 T C 10 4 1 . 1 0 G 0.6 % 17 . 6 % LOT 2 1.0% 3.8 % 1.5 % 0.0% 0.0% 1. 0 % 0.2% 10 4 1 . 0 5 10 4 0 . 9 6 10 4 0 . 8 7 10 4 0 . 9 6 10 4 0 . 8 7 10 4 0 . 7 8 10 4 0 . 5 5 T C 10 4 0 . 0 5 G (1 0 4 0 . 5 1 ) 10 4 1 . 3 0 T C 10 4 0 . 8 0 G 104 1 . 4 8 T C 104 0 . 9 8 G 104 1 . 5 7 T C 104 1 . 0 7 G 10 4 2 . 1 0 T C 10 4 1 . 6 0 G 10 4 1 . 8 0 1041.25 1041.16 104 1 . 2 6 1041.35 1041.67 10 4 1 . 4 0 10 4 0 . 6 4 1040 . 7 5 104 0 . 8 3 10 4 1 . 1 5 104 1 . 0 8 104 1 . 1 3 10 4 1 . 2 0 10 4 1 . 2 7 104 1 . 1 9 10 4 0 . 6 4 T C 10 4 0 . 1 4 G (1 0 4 0 . 1 7 ) 1041.28 10 4 1 . 7 5 10 4 1 . 7 5 10 4 1 . 3 5 104 1 . 1 3 T C 104 0 . 6 3 G 104 1 . 2 4 1041.29 1041.7 1 1041.75 1041.75 1041.71 104 1 . 1 6 1041.27 1041.33 1041.22 1041.16 1041.06 1041.58 FFE=1041.75LOT 1 1.0% 1.0% 1.0% 1.0% 1.0% 1.1 % 1.1 % 1.0 % 1.1 % 1.1 % 5.6% 4.5% 5.1% 5.6% 1.0%1.0% 1. 5 % 1. 5 % 1. 5 % 1.7 % 1.7 % 1.7 % 1.6 % 1.7 % 1.7 % 2.7 % 1.5 % 1.0%1.0% 1.0% 1.0% 1.0% 5.6% 1.0% 1.1% 1.0% 4.6%3.4 % 0.0% 1. 5 % 1.0 % 1.0% 0.2% 0. 7 % 1.5 % 0.1% 1041.40 TC 1040.90 G 1.0% 0.9 % 1041.70 104 1 . 5 0 1041 . 6 0 1041 . 2 6 104 1 . 2 1 104 0 . 6 7 1040 . 7 1 104 1 . 1 5 1041 . 1 9 104 1 . 6 0 103 9 . 7 8 103 9 . 7 1 1040.16 1040.21 1040.21 1040.26 1040.45 1040.45 1040 . 5 3 1040.40 TC 1039.90 G 10 4 0 . 5 3 1040 . 5 5 T C 1040 . 0 5 G 10 4 0 . 8 5 10 3 8 . 4 9 T C 10 3 7 . 9 9 G 1039.86 TC 1039.36 G 10 3 9 . 8 2 T C 10 3 9 . 3 2 G 10 3 9 . 4 5 10 3 8 . 9 3 10 3 9 . 1 7 10 3 9 . 5 2 10 3 9 . 9 5 1039.39 TC 1038.89 G C5 C12 4.2%1.4%7.8% 1.6% 1. 0 % 0. 8 % 0. 6 % 0.0% 1. 0 % 1. 0 % 1.0% 1.1% 1.4% 7. 5 % 0. 8 % 7.3%1.2%4.3% 7. 2 % 4. 0 % 3. 1 % -3:1 1.8% 2. 0 % 1.6 % 2.0 % 0.1% 0. 9 % 10 3 8 . 8 2 T C 10 3 8 . 3 2 G 103 7 . 5 5 32 . 9 1 ' 103 7 103 7 . 4 6 1037.19 1037.29 1036.95 1036.89 (1036.3 8 ) (1036.4 4 ) 1037.97 1037.93 10 3 8 . 4 1 10 3 8 . 4 8 10 3 8 . 4 8 10 3 8 . 5 4 8.0 % 8.1 % 1.0 % 4.5 % 1.6 % 4.5 % 1.6% 1.0% 0.8 % 3.9 % 4.0 % 4.8 % 3.6 % 1.8% 2.0% 1.0% 1.0% 10 3 8 . 6 7 10 3 8 . 7 2 2.0% 1.5% 1038 . 0 0 10 3 8 . 7 4 10 3 8 . 8 2 2.0 % 1.5 % 1.5% BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m ED C LJ M LM W 12 - 0 9 - 2 5 10 ' 12 5 . 1 3 9 6 . 0 1 C4 0 2 125.1396.01 C402 CA L I B E R K E T T L E S T O N E P L A T 1 RA M P D E T A I L S WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 12 - 2 3 - 2 5 01 - 0 6 - 2 6 01 - 2 0 - 2 6 02 - 0 3 - 2 6 LJ M LJ M LJ M LJ M 1234 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 5 \ 1 2 5 . 1 3 9 6 . 0 1 0 \ C A D D \ S P _ 1 2 5 1 3 9 6 _ R A M P . d w g LO G A N M Y E R S , RA M P D E T A I L S , 20 2 6 / 0 2 / 0 3 , 2: 2 5 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 10 10 15 3 7 11 6 12 14 8 11 12 9 10 14 9 TRASH 9 UP ST A I R ST A I R UP ST A I R ST A I R 42-PLEX 33,993 SF 66-PLEX 53,970 SF T T 22 - CK 13 - CK Outlot 'U' The Shops At Kettlestone North Plat 1 (Bk 2017, Pg 3256) 91,225 SF 2.09 AC LOT 1 Existing 30' Storm Sewer Easement (Book 2017, Page 3266) Existing 62' Public Ingress/Egress Easement (Book 2019, Page 10433) INGRESS/EGRESS EASEMENT (WIDTH VARIES) INGRESS/EGRESS EASEMENT (TO BE RECORDED IN SEPARATE DOCUMENT) TRAS H 14 16 18 8 9 16 12 411 10 7 2 UP 51 0 5 S F FU T U R E R E S T A U R A N T 10 9 489 S F EN T R Y 10 2 218 S F WO M E N 10 4 15 7 S F ME N10 3 38 S F UT I L . 11 0 VE N T CH A S E AB O V E SE R V I C E E N T R Y D3 D10 D1 6 D7 13 6 S F VE S T I B U L E 10 1 74 S F VE S T I B U L E 108D4 D1 D9D6 FLO O R / R O O F A B O V E FL O O R / R O O F A B O V E RO O F A B O V E RO O F A B O V E FLOO R / R O O F A B O V E ROOF A B O V E RO O F A B O V E D15 D17 D18 D18 D18 D18 D17 D3 D1 6 D14 PROP O S E D BUILD I N G 10,84 3 S F FFE= 1 0 4 1 . 9 0 1 3 100 BM501 Rim=1037.54 Inv=1023.91 8" TRUSS N Difficult To Determine Pipe Size SEESKERRIDGEDRIVE CON C R E T E GRA V E L CO N C R E T E S I D E W A L K CO N C R E T E S I D E W A L K SE PARKVIEW CROSSING DRIVE CO N C R E T E CONCRETE CONCRETE SIDEWALK CONCRETE CO N C R E T E CO N C R E T E S I D E W A L K CON C R E T E S I D E W A L K SEENCOMPASSDRIVE FIL L P I L E 14 - HA 14 - BG 17 - PS 18 - BG 2 - AG2 5 - HA 8 - CK 5 - EC 21 - PS 9 - PS 19 - CF 19 - BG 1 - TA 1 - TA 1 - GB 1 - GB 1 - QR 1 - QR 1 - AA2 1 - GI 1 - TA 1 - GI 1 - AA2 3 - GB 1 - QL 1 - QL 1 - QL 1 - QL 1 - CB 1 - SR 1 - AG2 1 - AG2 1 - SR 1 - QR 1 - AG2 1 - AG2 1 - GB 1 - GI 4 - TI 1 - GI 6 - TT 6 - TT 3 - CB 1 - CB 2 - SR 1 - SR 6 - GI 6 - MD 9 - MS 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 3 2 3 3 2 3 3 3 3 4 4 4 3 6 2 4 3 4 1 2 1 2 2 3 3 4 4 TYP TYP TYP TYP TYP TYP TYP TYPTYP TYP TYP TYP TYP TYP TYP 2' 2' 2' TYP TYP TYP 6 6 6 6 6 6 3' 6 6 6 6 3 4 3 4 4 3 7 - EC 2 - SR BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m ED C LJ M LM W 12 - 0 9 - 2 5 30 ' 12 5 . 1 3 9 6 . 0 1 C5 0 0 125.1396.01 C500 CA L I B E R K E T T L E S T O N E P L A T 1 PL A N T I N G P L A N WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 12 - 2 3 - 2 5 01 - 0 6 - 2 6 01 - 2 0 - 2 6 02 - 0 3 - 2 6 LJ M LJ M LJ M LJ M 1234 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 5 \ 1 2 5 . 1 3 9 6 . 0 1 0 \ C A D D \ S P _ 1 2 5 1 3 9 6 _ L N D . d w g LO G A N M Y E R S , PL A N T I N G P L A N , 20 2 6 / 0 2 / 0 3 , 2: 2 6 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FEET 0 30 PLANTING PLAN GENERAL NOTES A.UTILITY WARNING: THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR RECORDS OBTAINED. THE SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEY FURTHER DOES NOT WARRANT THAT THE UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED. B.NOTIFY UTILITY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXISTENCE, EXACT LOCATION AND DEPTH OF ALL UTILITIES. AVOID DAMAGE TO UTILITIES AND SERVICES DURING CONSTRUCTION. ANY DAMAGE DUE TO THE CONTRACTOR'S CARELESSNESS SHALL BE CORRECTED AT THE CONTRACTOR'S EXPENSE. COORDINATE AND COOPERATE WITH UTILITY COMPANIES DURING CONSTRUCTION. C.ALL PLANT MATERIAL SHALL AT LEAST MEET MINIMUM REQUIREMENTS SHOWN IN THE "AMERICAN STANDARDS FOR NURSERY STOCK" (ANSI Z60.1-LATEST EDITION). D.CONTRACTOR SHALL GUARANTEE ALL PLANT MATERIAL FOR A PERIOD OF ONE YEAR FROM DATE OF INSTALLATION. PLANTING PLAN CONSTRUCTION NOTES 1.SOD ALL DISTURBED AREAS UNLESS NOTED OTHERWISE. REFER TO EROSION CONTROL PLAN FOR ADDITIONAL INFORMATION. 2.PROVIDE A 3-IN DEPTH SHREDDED HARDWOOD MULCH IN A 3-FOOT PERIMETER RING AROUND ALL TREES. PROVIDE VERTICAL CUT NATURAL EDGE TO A DEPTH OF 4-INCHES. 3.PROVIDE 1-2'' RIVER ROCK TO A DEPTH OF 4-INCHES. TAPER MULCH DEPTH TOWARDS BED EDGING AND/OR PAVEMENT EDGE EXPOSING 1-INCH HEIGHT OF EDGE. 4.PROVIDE 3 /16 " BLACK STEEL EDGER WITH STAKES. 5.PLANTING SUBSTITUTIONS SHALL BE APPROVED IN WRITING BY THE COMMUNITY DEVELOPMENT DEPARTMENT. 6.ALL AREAS IN THE RIGHT-OF-WAY WILL BE REQUIRED TO BE SODDED. PLANTING PLAN REQUIREMENTS (LANDSCAPE CALCULATIONS BASED UPON CITY OF WAUKEE ZONING CODE REQUIREMENTS) OPEN SPACE: 20% OPEN SPACE REQUIRED 122,701.9 SF, 2.8 ACRES(TOTAL LOT) x 20% = 24,540.2 SF REQUIRED (25,416 SF OR 20.7% PROVIDED) 1.5 OVERSTORY TREES, 0.5 UNDERSTORY TREES, AND 2 SHRUB PER 1,000 SF OF REQUIRED OPEN SPACE. MINIMUM OF 50% OF TOTAL REQUIRED TREES SHALL BE OVERSTORY SHADE TREES. 24,540.2 SF /1,000 = 24.5 PLANT UNITS (PU'S) 1.5 OVERSTORY TREES x 24.5 PU'S = 36.75 TREES REQUIRED (50 TREES PROVIDED, 33 OVERSTORY, 16 EVERGREEN) 0.5 UNDERSTORY TREES X 18.3 PU'S = 12.25 UNDERSTORY TREES REQUIRED (13 PROVIDED) 2 SHRUBS X 24.5 PU'S = 49 SHRUBS REQUIRED (55 PROVIDED) STREET TREE REQUIREMENTS: ONE TREE FOR EVERY 40 FEET OF STREET FRONTAGE, NOT INCLUDING DRIVEWAY SE ESKER RIDGE PKWY: 280.2/40 = 7 TREES REQUIRED (7 PROVIDED) SE PARKVIEW CROSSING DRIVE: 360/ 40 = 9 TREES REQUIRED (9 PROVIDED) SE ENCOMPASS DRIVE: 275/40 = 6.8 TREES REQUIRED (7 PROVIDED) BUFFER REQUIREMENT: NO BUFFER REQUIRED. OFF-STREET PARKING AREA REQUIREMENT: 1 TREE FOR EVERY PARKING LOT ISLAND 16 PARKING LOT ISLANDS 16 TREES REQUIRED (16 TREES PROVIDED) TREE HEIGHT MINIMUM REQUIREMENTS OVERSTORY TREES MUST BE 8 FEET TALL MINIMUM AT TIME OF PLANTING. EVERGREEN TREES MUST BE 6 FEET TALL MINIMUM AT TIME OF PLANTING. ORNAMENTAL TREES MUST BE 6 FEET TALL MINIMUM AT TIME OF PLANTING. STREET TREES MUST BE 12 FEET TALL MINIMUM AT TIME OF PLANTING. CODE QTY BOTANICAL NAME COMMON NAME SIZE TYPE TREES AA2 2 Acer rubrum 'Armstrong'Armstrong Red Maple 2" Cal.B&B CB 5 Carpinus betulus European Hornbeam 2" Cal.B&B GB 6 Ginkgo biloba Maidenhair Tree 2" Cal.B&B GI 10 Gleditsia triacanthos inermis Thornless Honey Locust 2" Cal.B&B QL 4 Quercus robur x bicolor 'Long'Regal Prince® Oak 2" Cal.B&B QR 3 Quercus rubra Red Oak 2" Cal.B&B TA 3 Tilia americana American Linden 2" Cal.B&B EVERGREEN TREES TT 12 Thuja occidentalis 'Techny'Techny Arborvitae 6` Ht.B&B TI 4 Thuja x 'Green Giant'Green Giant Arborvitae 6` Ht.B&B ORNAMENTAL TREES AG2 6 Amelanchier x grandiflora 'Autumn Brilliance'Autumn Brilliance Apple Serviceberry 6` Ht.B&B MS 9 Malus x 'Spring Snow'Spring Snow Crabapple 6` Ht.B&B MD 6 Malus x adstringens 'Durleo'Gladiator™ Crabapple 6` Ht.B&B SR 7 Syringa reticulata Japanese Tree Lilac 6` Ht.B&B CODE QTY BOTANICAL NAME COMMON NAME SIZE CONTAINER SHRUBS BG 51 Buxus x 'Green Gem'Green Gem Boxwood 3 gal.Pot CF 19 Cornus sericea 'Farrow' TM Arctic Fire Red Twig Dogwood 3 gal.Pot EC 12 Euonymus alatus 'Compactus'Compact Burning Bush 3 gal.Pot HA 19 Hydrangea arborescens 'Annabelle'Annabelle Hydrangea 3 gal.Pot GRASSES CK 43 Calamagrostis x acutiflora 'Karl Foerster'Karl Foerster Feather Reed Grass 1 gal.Pot PS 47 Panicum virgatum 'Shenandoah'Shenandoah Switch Grass 1 gal.Pot BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m ED C LJ M LM W 12 - 0 9 - 2 5 12 5 . 1 3 9 6 . 0 1 C6 0 0 125.1396.01 C600 CA L I B E R K E T T L E S T O N E P L A T 1 SI T E D E T A I L S WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 12 - 2 3 - 2 5 01 - 0 6 - 2 6 01 - 2 0 - 2 6 02 - 0 3 - 2 6 LJ M LJ M LJ M LJ M 1234 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 5 \ 1 2 5 . 1 3 9 6 . 0 1 0 \ C A D D \ S P _ 1 2 5 1 3 9 6 _ T S H . d w g LO G A N M Y E R S , SI T E D E T A I L S , 20 2 6 / 0 2 / 0 3 , 2: 2 6 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) FORM GRADE ELEV. 6" 4 C600 INTEGRAL SIDEWALK AND CURB DETAIL NO SCALE ADJACENT PAVEMENT SIDEWALK 4" M I N 2 C600 TYPICAL PAVEMENT CROSS SECTIONS NO SCALE PCC PAVEMENT SECTION PCC SIDEWALK SECTION SLOPE AS PER PLANS 2% MAX 4 1 2" 7 1 2" 6" 12"18" 3 C600 6-INCH STANDARD CURB NO SCALE R3" R3" 1" RADIUS SEALED 'E' JOINT PCC PAVEMENT, SEE PLANS FOR THICKNESS & LOCATIONS 12" DEPTH PREPARED SUBGRADE 2 - 6" LIFTS UNLESS NOTED OTHERWISE SIDEWALK PAVEMENT, SEE PLANS FOR THICKNESS & LOCATIONS 6" DEPTH PREPARED SUBGRADE Rise Tread SIDEWALK 1 C600 PCC STAIRS WITH RAILING NO SCALE BENT BAR SECTION A-A 8" M I N PLAN SECTION B-B A A B B ZY 2% 15"6" POSSIBLE SIDEWALK POSSIBLE SIDEWALK 3 1 PROVIDE A MINIMUM OF 2 INCHES OF COVER FOR ALL REINFORCING. 2 ENSURE ALL RISERS ARE AN EQUAL HEIGHT AND ALL TREADS ARE AN EQUAL DEPTH WITHIN A FLIGHT OF STAIRS. 3 MATCH EXISTING SIDEWALK WIDTH. 4 CONSTRUCT CROSS SLOPE OF LANDING TO MATCH ADJACENT SIDEWALK. 5 HANDRAIL TO BE 1 1 2" O.D. POWDER-COATED STEEL HANDRAIL SET IN SLEEVE PER MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS. COLOR TO BE APPROVED BY OWNER. VA R I E S 1'-6" Z Y 1" 8" 2' - 0 " 12" 24" 5'-0" MAX SPACING 30" 12"15" 2' - 1 0 " T O 3 ' - 2 " 6" LENGTH WI D T H (V A R I E S ) 1 2" MAX RADIUS #4 1" PREFORMED EXPANSION JOINT SIDE RAIL (MATCH HEIGHT AND BATTER OF RETAINING WALL) 4 #4 @ 18" C-C 1" PREFORMED EXPANSION JOINT RETAINING WALL POSTS HANDRAIL #4 @ 12" C-C #4 @ 18" C-C 2 #4 BARS IN TOP OF EACH SIDE RAIL SIDE RAIL #4 BENT BAR @14" C-C 5 C600 OUTLET STRUCTURE DETAIL (ST-12) NO SCALE 18" OUTLET PIPE INV:1028.25' PROPOSED 3" DIAMETER HOLE ELEV:1028.25 TOP OF WEIR WALL ELEV:1033.65' (CPV ELEVATION) PROPOSED 30" NYLOPLAST DRAIN STRUCTURE 10" SUMP NOTE: THE OWNER WILL INSPECT THE SYSTEM ON A BI-ANNUAL BASIN. IF SEDIMENT IS BLOCKING THE 3” ORIFICE IN THE OUTLET STRUCTURE, JET / VACUUM THE SYSTEM TO REMOVE THE SEDIMENT. 24" x 24" MANIFOLD INV:1030.21 24" BOTTOM CONNECTION INV:1029.17 BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m ED C LJ M LM W 12 - 0 9 - 2 5 12 5 . 1 3 9 6 . 0 1 C6 0 1 125.1396.01 C601 CA L I B E R K E T T L E S T O N E P L A T 1 SI T E D E T A I L S WA U K E E , I O W A AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 12 - 2 3 - 2 5 01 - 0 6 - 2 6 01 - 2 0 - 2 6 02 - 0 3 - 2 6 LJ M LJ M LJ M LJ M 1234 TT N - R R W - S S V: \ P r o j e c t s \ 2 0 2 5 \ 1 2 5 . 1 3 9 6 . 0 1 0 \ C A D D \ S P _ 1 2 5 1 3 9 6 _ T S H . d w g LO G A N M Y E R S , SI T E D E T A I L S , 20 2 6 / 0 2 / 0 3 , 2: 2 6 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) SUMP DEPTH = 24" PROVIDE FLEXSTORM ON ST- 8 S61°28'13"E 1.86' M S61°42'02"E 1.86' R 10.01' S2 6 ° 5 5 ' 1 9 " W 3 2 2 . 7 1 ' M S2 6 ° 4 1 ' 3 0 " W 3 2 2 . 7 1 ' R S89°39'24"E 166.54' M S89°53'50"E 166.59' R S61°28'13"E 1.86' M S61°42'02"E 1.86' R C1 C2 C3 C4 C5 30' Storm Sewer Easement (Book 2017, Page 3266) Ingress/Egress Easement (Width Varies (Inst. No. 2025-16190) Ingress/Egress Easement (Width Varies) (Inst. No. 2025-16190) 30' Temporary Construction Easement (Inst. No. 2025-16190) Public 15' Water Main Easement (Book 2019, Page 10432) Public 62' Ingress/Egress Easement (Book 2019, Page 10433) Public 6 2 ' I n g r e s s / E g r e s s Easeme n t (Book 2 0 1 9 , P a g e 1 0 4 3 3 ) 20' Sanitary Sewer Easement (Book 2019, Page 10436) S1°27'18"E 47.22' M S1°43'08"E 47.15' R 49,530 SF 1.14 AC LOT 1 73,073 SF 1.68 AC LOT 2 32 . 9 1 ' N88°07'26"E 49.03' N2 6 ° 5 5 ' 1 9 " E 27 7 . 3 7 ' C12 SE E S K E R R I D G E D R I V E (R. O . W . V A R I E S ) SE P A R K V I E W C R O S S I N G D R I V E 10' PUBLIC UTILITY EASEMENT 10' PUBLIC UTILITY EASEMENT PARCEL 1 8 - 1 6 3 (BOOK 2 0 1 8 , P A G E 2 3 7 8 2 ) BEING A P A R T O F OUTLOT B THE SH O P S A T K E T T L E S T O N E N O R T H P L A T 5 OUTLOT A THE SH O P S A T KETTLE S T O N E NORTH P L A T 7 LOT 1 THE SH O P S A T KETTLE S T O N E N O R T H PLAT 8 S2 6 ° 5 5 ' 1 9 " W 3 2 2 . 7 1 ' M & P S2 6 ° 4 1 ' 3 0 " W 3 2 2 . 7 1 ' R S89°39'24"E 166.54' M S89°53'50"E 166.59' R S1°27'18"E 47.22' M S1°43'08"E 47.15' R S43°58'48"W 1.52' C6 N63°04'41"W 8.92' C7 S2 6 ° 5 5 ' 1 9 " W 2 2 0 . 4 3 ' C8 S54 ° 3 7 ' 5 8 " E 1 2 2 . 9 6 ' S26°35'58"W 10.59' C9 N54 ° 3 7 ' 5 8 " W 1 2 6 . 5 3 ' C1 0 N2 6 ° 5 5 ' 1 9 " E 2 7 4 . 5 0 ' C11 S63°04'41"E 14.28' SE E N C O M P A S S D R I V E LOT 1 THE SH O P S A T K E T T L E S T O N E NORTH P L A T 9 70' R.O.W. L2 L3 13' 13' 26' PRIVATE INGRESS/EGRESS EASEMENT L4 L5 L6 S3 1 ° 0 4 ' 3 0 " E 2 2 1 . 6 7 ' N3 1 ° 0 4 ' 3 0 " W 2 4 1 . 9 4 ' 20' PRIVATE SANITARY SEWER EASEMENT S37°47'08"W 4.04' S42°16'08"E 24.98' S55°16'36"E 16.01' PUBLIC SIDEWALK EASEMENT C7 C8 C9 C10 C11 C12 C6 32°04'21" 81°33'17" 3°08'50" 81°33'17" 45°35'47" 38°08'08" 12°29'56" 243.00' 20.00' 285.00' 46.00' 217.00' 230.00' 115.00' 136.02' 28.47' 15.65' 65.48' 172.69' 153.09' 25.09' 69.85' 17.25' 7.83' 39.67' 91.21' 79.50' 12.59' N47°02'30"W 134.25' S13°51'19"E 26.12' S28°10'23"W 15.65' N13°51'19"W 60.09' S40°16'47"E 168.17' S44°00'37"E 150.28' S38°14'30"W 25.04' LINE TABLE LINE # L1 L2 L3 L4 L5 L6 LENGTH (FT) 24.97 27.06 15.77 3.80 20.97 23.58 DIRECTION S63° 04' 41"E N26° 55' 19"E N54° 37' 58"W N02° 30' 53"E S89° 39' 24"E S26° 55' 19"W CURVE TABLE CURVE NO. C1 M C2 M C3 M C4 M C5 M Δ 11°29'52" 7°30'35" 78°38'08" 21°42'40" 59°58'38" RADIUS 1065.00' 535.00' 25.00' 935.00' 246.00' ARC LENGTH 213.72' 70.12' 34.31' 354.30' 257.51' TANGENT 107.22' 35.11' 20.48' 179.30' 141.96' CHORD BEARING/LENGTH N52°50'50"W 213.36' N50°44'56"W 70.07' N15°02'44"W 31.68' N13°16'38"E 352.19' S31°28'30"E 245.92' C1 P 11°29'52"1065.00'213.72'-N53°04'39"W 213.36' C2 P 7°30'09"535.00'70.06'-- C3 P 78°44'20"25.00'34.36'-- C4 P 21°42'48"935.00'354.34'-- C5 P 59°58'54"246.00'257.53'-- (915 SE ESKER RIDGE DRIVE) (845 SE ESKER RIDGE DRIVE) C13 C14 C13 C14 49°08'29" 2°17'22" 25.00' 535.00' 21.44' 21.38' 11.43' 10.69' N29°47'34"W 20.79' N53°21'33"W 21.38' Found 1/2" Rebar With Blue Plastic Cap #19880 NE Corner Parcel 18-163 & NW Corner Lot 1 The Shops At Kettlestone North Plat 9 Found 1/2" Rebar With Yellow Plastic Cap #19710 SE Corner Parcel 18-163 & SW Corner Lot 1 The Shops At Kettlestone North Plat 9 Found 5/8" Rebar With Yellow Plastic Cap #13156 Found 1/2" Rebar With Blue Plastic Cap #19880 SW Corner Parcel 18-163 Found 1/2" Rebar With Blue Plastic Cap #19880 NW Corner Parcel 18-163 Found 1/2" Rebar With Blue Plastic Cap #19880 NE Corner Parcel 18-163 Found 1/2" Rebar Found 1/2" Rebar With Blue Plastic Cap #19880 Public 15' Water Main Easement (Book 2019, Page 10432) V: \ P r o j e c t s \ 2 0 2 5 \ 1 2 5 . 1 3 9 6 . 0 1 0 \ C A D D \ F P _ 1 2 5 1 3 9 6 _ B N D Y . d w g AD A V E N P O R T , 22 X 3 4 E X H I B I T L , 20 2 6 / 0 2 / 0 3 , 2: 3 0 P M , AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) BY DA T E RE V I S I O N MA R K Sc a l e : Te c h n i c i a n : T- R - S : SN Y D E R & A S S O C I A T E S , I N C . | Ch e c k e d B y : En g i n e e r : Da t e : 1" = Pr o j e c t N o : Sh e e t Project No: Sheet 27 2 7 S . W . S N Y D E R B L V D AN K E N Y , I O W A 5 0 0 2 3 51 5 - 9 6 4 - 2 0 2 0 | w w w . s n y d e r - a s s o c i a t e s . c o m AJ D DC G ED C 12 - 8 - 2 0 2 5 30 ' 12 5 . 1 3 9 6 . 0 1 1 O F 1 125.1396.01 1 OF 1 CA L I B E R K E T T L E S T O N E P L A T 1 FI N A L P L A T WA U K E E , I O W A A S P E R C I T Y C O M M E N T S A S P E R C I T Y C O M M E N T S AS P E R C I T Y C O M M E N T S 12 - 2 3 - 2 5 01 - 0 6 - 2 6 02 - 0 3 - 2 6 LJ M LJ M AJ D 123 78 N - 2 6 W - 0 4 FEET 0 30 AREA ABOVE RESERVED FOR RECORDER INDEX LEGEND SURVEYOR'S NAME / RETURN TO: AUSTIN J. DAVENPORT ADAVENPORT@SNYDER-ASSOCIATES.COM SERVICE PROVIDED BY: SNYDER & ASSOCIATES, INC. SURVEY LOCATED: PARCEL 18-163 PT. OUTLOT B SHOPS AT KETTLESTONE NORTH PLAT 5 SEC. 04-78N-26W REQUESTED BY: MN WAUKEE HOLDINGS LLC CALIBER KETTLESTONE PLAT 1 FINAL PLAT SNYDER & ASSOCIATES, INC. 2727 S.W. SNYDER BLVD ANKENY, IOWA 50023 515-964-2020 LEGEND FEATURES FOUND SET PLSS Section Corner Land Survey Monument (1/2" Rebar, OPC # P29380 Unless Otherwise Noted) R.O.W. Rail Centerline Reference Monument (Cut "X", Unless Otherwise Noted) Calculated Corner Platted Distance P Measured Bearing & Distance M Recorded As R Deed Distance D Calculated Distance C Orange Plastic Cap OPC Centerline Section Line 1/4 Section Line 1/4 1/4 Section Line Easement Line PROPERTY DESCRIPTION (WARRANTY DEED - DOCUMENT NUMBER: 2023-19143) PARCEL 18-163 OF PLAT OF SURVEY RECORDED IN BOOK 2018 PAGE 23782, BEING A PART OF OUTLOT B OF THE SHOPS AT KETTLESTONE NORTH PLAT 5, AN OFFICIAL PLAT, NOW INCLUDED IN AND FORMING A PART OF THE CITY OF WAUKEE, DALLAS COUNTY,IOWA. PROPERTY ADDRESS 915 AND 845 SE ESKER RIDGE WAUKEE, IOWA 50263 DATE OF SURVEY DECEMBER 8, 2025 PROPERTY OWNER MN WAUKEE HOLDINGS LLC 1409 N RIVERFRONT DR MANKATO, MN 56001 AREA SUMMARY GROSS AREA: 2.82 ACRES (122,603 SF) ZONING K-MU/PD-1 OVERLAY: KETTLESTONE MULTI-FAMILY/ PLANNED DEVELOPMENT DISTRICT OVERLAY (PER ZONING ORDINANCE #2896) BULK REGULATIONS LOT AREA: NO MINIMUM REQUIREMENT LOT WIDTH: NO MINIMUM REQUIREMENT FRONT YARDS: NO MINIMUM FOR PRINCIPAL PERMITTED USES. 20 FEET FOR ACCESSORY STRUCTURES SIDE YARDS: NO MINIMUM FOR PRINCIPAL PERMITTED USES UNLESS ADJACENT TO ADJOINING SINGLE-FAMILY, IN WHICH CASE THE MINIMUM SETBACK SHALL BE 50 FEET. 5 FEET FOR ACCESSORY STRUCTURES. REAR YARD: NO MINIMUM FOR PRINCIPAL PERMITTED USES UNLESS ADJACENT TO ADJOINING SINGLE-FAMILY, IN WHICH CASE THE MINIMUM SETBACK SHALL BE 50 FEET. 5 FEET FOR ACCESSORY STRUCTURES. MAXIMUM HEIGHT: PRINCIPAL BUILDING - 8 STORIES ACCESSORY BUILDING - 1 STORY FLOODPLAIN THE FLOOD ZONE DESIGNATION FOR THE SUBJECT PROPERTY IS ZONE X, BEING AREA OF MINIMAL FLOOD HAZARD, AS PER THE FLOOD INSURANCE RATE MAP FOR THE CITY OF WAUKEE, IOWA, PANEL NUMBER 19049C0355F, EFFECTIVE DATE DECEMBER 07, 2018. PLAT AREA GR A N D P R A I R I E P K W Y SE P A R K V I E W C R O S S I N G D R I V E SE E S K E R R I D G E D R I V E SE TALLG R A S S L A N E VICINITY MAP WAUKEE, IOWA (1"=200') SE E N C O M P A S S D R I V E Austin J. Davenport, PLS Date License Number P29380 My License Renewal Date is December 31, 2027 Pages or sheets covered by this seal: AUSTIN J. DAVENPORT P29380 AIOW LICENSEDPROFESSIONAL LANDSURVEYOR I hereby certify that this land surveying document was prepared and the related survey work was performed by me or under my direct personal supervision and that I am a duly licensed Professional Land Surveyor under the laws of the State of Iowa. SHEET 1 OF 1. DRAF T UP 721 SF UNIT 101 1 BED 690 SF UNIT 102 1 BED 665 SF UNIT 103 SUITE 665 SF UNIT 117 SUITE 665 SF UNIT 119 SUITE 721 SF UNIT 121 1 BED -TYPE A 669 SF UNIT 104 SUITE 873 SF UNIT 118 2 BED 669 SF UNIT 120 SUITE 691 SF UNIT 122 1 BED STAIRSTAIR MECH EXIT PASSAGE 873 SF UNIT 106 2 BED 892 SF UNIT 116 2 BED 665 SF UNIT 105 SUITE 665 SF UNIT 115 SUITE 816 SF UNIT 112 SUITE 873 SF UNIT 114 2 BED 892 SF UNIT 108 2 BED873 SF UNIT 110 2 BED 665 SF UNIT 107 SUITE 665 SF UNIT 109 SUITE 665 SF UNIT 111 SUITE 665 SF UNIT 113 SUITE 79 ' - 1 1 " 236'-7" 3611 NE Otterview Cir #42 Ankeny, IA 50021 www.jcorpdesignbuild.com CONTENTS: SHEET NO: PROJECT NO: PR O J E C T : REVISIONS: M1 25-021 Wa u k e e A p a r t m e n t s - 6 6 P l e x 01 / 20 / 2026 1st Floor Plan Wa u k e e , I A 5 0 2 6 3 01/20/2026 SITE SUBMITTAL 84 5 S o u t h e a s t E s k e r R i d g e D r i v e 1 2 NORTH SCALE:1/8" = 1'-0"1 1ST FLOOR - MARKETING SF: 18,243 UNIT SCHEDULE TYPE COUNT AREA 1 BED 11 690 SF ... 768 SF 1 BED - TYPE A 1 721 SF 2 BED 20 873 SF ... 892 SF SUITE 34 665 SF ... 816 SF DN UP 738 SF UNIT 202 1 BED 669 SF UNIT 204 SUITE 873 SF UNIT 218 2 BED 669 SF UNIT 220 SUITE 738 SF UNIT 222 1 BED 768 SF UNIT 221 1 BED 665 SF UNIT 219 SUITE 665 SF UNIT 217 SUITE 873 SF UNIT 206 2 BED 892 SF UNIT 216 2 BED 665 SF UNIT 215 SUITE 665 SF UNIT 205 SUITE 665 SF UNIT 203 SUITE 768 SF UNIT 201 1 BED STAIRSTAIR 231'-2" 79 ' - 1 1 " 873 SF UNIT 212 2 BED 873 SF UNIT 214 2 BED 892 SF UNIT 208 2 BED873 SF UNIT 210 2 BED 665 SF UNIT 207 SUITE 665 SF UNIT 209 SUITE 665 SF UNIT 211 SUITE 665 SF UNIT 213 SUITE 3611 NE Otterview Cir #42 Ankeny, IA 50021 www.jcorpdesignbuild.com CONTENTS: SHEET NO: PROJECT NO: PR O J E C T : REVISIONS: M2 25-021 Wa u k e e A p a r t m e n t s - 6 6 P l e x 01 / 20 / 2026 2nd and 3rd Floor Plan Wa u k e e , I A 5 0 2 6 3 01/20/2026 SITE SUBMITTAL 84 5 S o u t h e a s t E s k e r R i d g e D r i v e 1 2 NORTH SCALE:1/8" = 1'-0"1 2ND AND 3RD FLOOR - MARKETING SF: 17,904 UNIT SCHEDULE TYPE COUNT AREA 1 BED 11 690 SF ... 768 SF 1 BED - TYPE A 1 721 SF 2 BED 20 873 SF ... 892 SF SUITE 34 665 SF ... 816 SF ROOF ACCESS HATCH 1/ 4 " / 1 2 " 1'-0" 84 ' - 0 " 1/4" / 12"1/4" / 12" 1/ 4 " / 1 2 " 1/ 4 " / 1 2 " 1/4" / 12" ROOF DRAINROOF DRAIN ROOF DRAIN RTURTU RTURTU RTURTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTURTU OVERFLOW DRAIN OVERFLOW DRAIN ROOF DRAIN ROOF DRAINROOF DRAIN OVERFLOW DRAINOVERFLOW DRAIN RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU 234'-2" 3611 NE Otterview Cir #42 Ankeny, IA 50021 www.jcorpdesignbuild.com CONTENTS: SHEET NO: PROJECT NO: PR O J E C T : REVISIONS: M3 25-021 Wa u k e e A p a r t m e n t s - 6 6 P l e x 01 / 20 / 2026 Roof Plan Wa u k e e , I A 5 0 2 6 3 01/20/2026 SITE SUBMITTAL 84 5 S o u t h e a s t E s k e r R i d g e D r i v e 1 2 NORTH SCALE:1/8" = 1'-0"1 ROOF PLAN - MARKETING 40 ' - 6 " B1B2 B1 B1 B1 METER LOCATION 40 ' - 6 " B1 B2B1S1 B1 B1S1 B1B1 S1B1 B1 S1B1S1 B1 S1 B1 B1 B1 S1B1B1B2 B1 B2B2 METAL PARAPET CAP TYPHARDIE FIBER CEMENT FASCIA PAINTED SW 6258 TRICORN BLACK (TYP.) B2B1 B1 B1 S1 B1 B1B1 B1 B1 B1 B1B1 B1B1B2 S1 S1 S1S1S1S1 B1 B2 B2 B1B2B1B1 3611 NE Otterview Cir #42 Ankeny, IA 50021 www.jcorpdesignbuild.com CONTENTS: SHEET NO: PROJECT NO: PR O J E C T : REVISIONS: M4 25-021 Wa u k e e A p a r t m e n t s - 6 6 P l e x 01 / 20 / 2026 Elevations Wa u k e e , I A 5 0 2 6 3 01/20/2026 SITE SUBMITTAL 84 5 S o u t h e a s t E s k e r R i d g e D r i v e 1 2 SCALE:1/8" = 1'-0"2 WEST ELEVATION SCALE:1/8" = 1'-0"1 NORTH ELEVATION SCALE:1/8" = 1'-0"3 EAST ELEVATION SCALE:1/8" = 1'-0"4 SOUTH ELEVATION MATERIAL SCHEDULE - WEST Type Description Area Percentage B1 Modular Brick - 80% Granite Red Velour 20% Carbon Black Velour - Running Bond 2692 SF 40% B2 Modular Brick - Carbon Black Velour - Running Bond 1881 SF 28% S1 Fiber Cement Lap Siding - SW 7017 Dorian Gray 2224 SF 33% Glazing 2291 SF 25% 24% 21% 30% MATERIAL SCHEDULE - NORTH Type Description Area Percentage B1 Modular Brick - 80% Granite Red Velour 20% Carbon Black Velour - Running Bond 1524 SF 62% B2 Modular Brick - Carbon Black Velour - Running Bond 924 SF 38% Glazing 594 SF 20% 30% 50% MATERIAL SCHEDULE - SOUTH Type Description Area Percentage B1 Modular Brick - 80% Granite Red Velour 20% Carbon Black Velour - Running Bond 1440 SF 61% B2 Modular Brick - Carbon Black Velour - Running Bond 934 SF 39% Glazing 651 SF 21% 31% 48% MATERIAL SCHEDULE - EAST Type Description Area Percentage B1 Modular Brick - 80% Granite Red Velour 20% Carbon Black Velour - Running Bond 2574 SF 38% B2 Modular Brick - Carbon Black Velour - Running Bond 1889 SF 28% S1 Fiber Cement Lap Siding - SW 7017 Dorian Gray 2228 SF 33% Glazing 2165 SF 25% 25% 1% 29% 3611 NE Otterview Cir #42 Ankeny, IA 50021 www.jcorpdesignbuild.com CONTENTS: SHEET NO: PROJECT NO: PR O J E C T : REVISIONS: M5 25-021 Wa u k e e A p a r t m e n t s - 6 6 P l e x 01 / 20 / 2026 Perspectives Wa u k e e , I A 5 0 2 6 3 01/20/2026 SITE SUBMITTAL 84 5 S o u t h e a s t E s k e r R i d g e D r i v e 1 2 UP 721 SF UNIT 101 1 BED -TYPE A 691 SF UNIT 102 1 BED 665 SF UNIT 103 SUITE 665 SF UNIT 109 SUITE 665 SF UNIT 111 SUITE 721 SF UNIT 113 1 BED 669 SF UNIT 104 SUITE 873 SF UNIT 110 2 BED 669 SF UNIT 112 SUITE 691 SF UNIT 114 1 BED STAIRSTAIR MECH EXIT PASSAGE 873 SF UNIT 106 2 BED 835 SF UNIT 108 SUITE 665 SF UNIT 105 SUITE 665 SF UNIT 107 SUITE 79 ' - 1 1 " 152'-7" 3611 NE Otterview Cir #42 Ankeny, IA 50021 www.jcorpdesignbuild.com CONTENTS: SHEET NO: PROJECT NO: PR O J E C T : REVISIONS: M1 25-021 Wa u k e e A p a r t m e n t s - 4 2 P l e x 01 / 20 / 2026 1st Floor Plan Wa u k e e , I A 5 0 2 6 3 01/20/2026 SITE SUBMITTAL 91 5 S o u t h e a s t E s k e r R i d g e D r i v e 1 2NORTHSCALE:3/16" = 1'-0"1 1ST FLOOR - MARKETING SF: 11,570 UNIT SCHEDULE TYPE COUNT AREA 1 BED 11 691 SF ... 768 SF 1 BED - TYPE A 1 721 SF 2 BED 8 873 SF ... 892 SF SUITE 22 665 SF ... 835 SF DN UP 738 SF UNIT 202 1 BED 669 SF UNIT 204 SUITE 873 SF UNIT 210 2 BED 669 SF UNIT 212 SUITE 738 SF UNIT 214 1 BED 768 SF UNIT 213 1 BED 665 SF UNIT 211 SUITE 665 SF UNIT 209 SUITE 873 SF UNIT 206 2 BED 892 SF UNIT 208 2 BED 665 SF UNIT 207 SUITE 665 SF UNIT 205 SUITE 665 SF UNIT 203 SUITE 768 SF UNIT 201 1 BED STAIRSTAIR 147'-2" 79 ' - 1 1 " 3611 NE Otterview Cir #42 Ankeny, IA 50021 www.jcorpdesignbuild.com CONTENTS: SHEET NO: PROJECT NO: PR O J E C T : REVISIONS: M2 25-021 Wa u k e e A p a r t m e n t s - 4 2 P l e x 01 / 20 / 2026 2nd and 3rd Floor Plan Wa u k e e , I A 5 0 2 6 3 01/20/2026 SITE SUBMITTAL 91 5 S o u t h e a s t E s k e r R i d g e D r i v e 1 2NORTHSCALE:3/16" = 1'-0"1 2ND AND 3RD FLOOR - MARKETING SF: 11,231 UNIT SCHEDULE TYPE COUNT AREA 1 BED 11 691 SF ... 768 SF 1 BED - TYPE A 1 721 SF 2 BED 8 873 SF ... 892 SF SUITE 22 665 SF ... 835 SF ROOF ACCESS HATCH ROOF DRAINROOF DRAIN ROOF DRAIN ROOF DRAIN 1/ 4 " / 1 2 " 1/4" / 12" 1/ 4 " / 1 2 " 1/4" / 12" 1/ 4 " / 1 2 " 84 ' - 0 " 150'-2" RTU RTU RTU RTU RTU RTU RTURTU RTURTU RTURTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTU RTURTU OVERFLOW DRAIN OVERFLOW DRAIN 1/4" / 12" 3611 NE Otterview Cir #42 Ankeny, IA 50021 www.jcorpdesignbuild.com CONTENTS: SHEET NO: PROJECT NO: PR O J E C T : REVISIONS: M3 25-021 Wa u k e e A p a r t m e n t s - 4 2 P l e x 01 / 20 / 2026 Roof Plan Wa u k e e , I A 5 0 2 6 3 01/20/2026 SITE SUBMITTAL 91 5 S o u t h e a s t E s k e r R i d g e D r i v e 1 2NORTHSCALE:3/16" = 1'-0"1 ROOF PLAN - MARKETING B1 B2 B1 B1 40 ' - 6 " 40 ' - 6 " B1B2 B1 S1 S1 S1 S1B1B1 B1 B1 B2 B1 B1 B1 B1 B1 B2 HARDIE FIBER CEMENT FASCIA PAINTED SW 6258 TRICORN BLACK (TYP.) METAL PARAPET CAP TYP B1 S1 B1 B1 B1 B1 B1B1B1 S1S1 S1 S1 B2B2 B1 B1 B2 B1B1 METER LOCATION B1 3611 NE Otterview Cir #42 Ankeny, IA 50021 www.jcorpdesignbuild.com CONTENTS: SHEET NO: PROJECT NO: PR O J E C T : REVISIONS: M4 25-021 Wa u k e e A p a r t m e n t s - 4 2 P l e x 01 / 20 / 2026 Elevations Wa u k e e , I A 5 0 2 6 3 01/20/2026 SITE SUBMITTAL 91 5 S o u t h e a s t E s k e r R i d g e D r i v e 1 2 SCALE:1/8" = 1'-0"2 EAST ELEVATION SCALE:1/8" = 1'-0"4 SOUTH ELEVATION SCALE:1/8" = 1'-0"3 WEST ELEVATION SCALE:1/8" = 1'-0"1 NORTH ELEVATION MATERIAL SCHEDULE - EAST Type Description Area Percentage B1 Modular Brick - 80% Granite Red Velour 20% Carbon Black Velour - Running Bond 2046 SF 48% B2 Modular Brick - Carbon Black Velour - Running Bond 987 SF 23% S1 Fiber Cement Lap Siding - SW 7017 Dorian Gray 1271 SF 30% MATERIAL SCHEDULE - NORTH Type Description Area Percentage B1 Modular Brick - 80% Granite Red Velour 20% Carbon Black Velour - Running Bond 1512 SF 62% B2 Modular Brick - Carbon Black Velour - Running Bond 924 SF 38% MATERIAL SCHEDULE - SOUTH Type Description Area Percentage B1 Modular Brick - 80% Granite Red Velour 20% Carbon Black Velour - Running Bond 1452 SF 61% B2 Modular Brick - Carbon Black Velour - Running Bond 934 SF 39% MATERIAL SCHEDULE - WEST Type Description Area Percentage B1 Modular Brick - 80% Granite Red Velour 20% Carbon Black Velour - Running Bond 1969 SF 47% B2 Modular Brick - Carbon Black Velour - Running Bond 995 SF 23% S1 Fiber Cement Lap Siding - SW 7017 Dorian Gray 1270 SF 30% Glazing 1476 SF 26% 22% 17% 35% Glazing 594 SF 20% 30% 50% Glazing 651 SF 21% 31% 48% Glazing 1404 SF 25% 22% 18% 35% 3611 NE Otterview Cir #42 Ankeny, IA 50021 www.jcorpdesignbuild.com CONTENTS: SHEET NO: PROJECT NO: PR O J E C T : REVISIONS: M5 25-021 Wa u k e e A p a r t m e n t s - 4 2 P l e x 01 / 20 / 2026 Perspectives Wa u k e e , I A 5 0 2 6 3 01/20/2026 SITE SUBMITTAL 91 5 S o u t h e a s t E s k e r R i d g e D r i v e 1 2 6" 13 ' - 0 " 6" 6"10"20'-4"10"6" 14 ' - 0 " M1 6 1'-7"9'-2" 10'-0" LONG x 0'-6" DIA CONCRETE FILLED GATE POST ENCASED IN FOOTING WITH 6'-0" ABOVE GRADE TYP WALL SECTION 6"9'-2"1'-7" 22'-0" 23'-0" 6'-0" TALL -METAL TRASH ENCLOSURE GATE PAINTED BLACK MODULAR BRICK -80% GRANITE RED VELOUR 20% CARBON BLACK VELOUR -RUNNING BOND MODULAR BRICK -80% GRANITE RED VELOUR 20% CARBON BLACK VELOUR -RUNNING BOND MODULAR BRICK -80% GRANITE RED VELOUR 20% CARBON BLACK VELOUR -RUNNING BOND MODULAR BRICK -80% GRANITE RED VELOUR 20% CARBON BLACK VELOUR -RUNNING BOND BLACK METAL CAP -TYP. 6' - 0 " PARAPET CAP FLASHING 6" CMU BRICK TO MATCH BUILDING (1) #4 CONT. #4's @ 48" O.C. (1) #5 CONT. T&B #4's @ 24" O.C. METAL DRIP EDGE ABOVE FINISH GRADE -VERIFY WITH G.C. MORTAR DEFLECTION DEVICE w/ MORTAR MAZE CELL VENTS @ 24" O.C. HEAD JOINTS THRU-WALL FLASHING EYE & PINTLE WALL TIES @ 16" O.C. 1'-0" 3' - 4 " 8" SCALE:3/8" = 1'-0"4 FRONT ELEVATION SCALE:3/8" = 1'-0"5 REAR ELEVATION 3611 NE Otterview Cir #42 Ankeny, IA 50021 www.jcorpdesignbuild.com CONTENTS: SHEET NO: PROJECT NO: PR O J E C T : REVISIONS: M1 25-021 Wa u k e e A p t s - T r a s h E n c l o s u r e 12 / 09 / 2025 Plan, Elevations, Sections Wa u k e e , I A 5 0 2 6 3 12/09/2025 SITE SUBMITTAL Th e S h o p s a t K e t t l e s t o n e N o r t h P l a t 5 P a r c e l 1 8 - 1 6 3 O u t l o t B SCALE:3/8" = 1'-0"1 PLAN SCALE:3/8" = 1'-0"3 LEFT ELEVATION SCALE:3/8" = 1'-0"2 RIGHT ELEVATION SCALE:1 1/2" = 1'-0"6 SECTION