HomeMy WebLinkAbout2021-03-01-J10 Shine Shop Carwash - Site Plan AGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: March 1, 2021 AGENDA ITEM: Consideration of approval of a resolution approving a site plan for Shine Shop Carwash (1400 SE University Avenue) FORMAT: Resolution SYNOPSIS INCLUDING PRO & CON: Splash Express, LLC, requests approval of a site plan for a 4,500 square feet building that will contain a car wash. The site plan also identifies vacuums to the east of the proposed building, a vacuum equipment enclosure at the east side of the site and a trash enclosure at the southeast corner of the site. Access to the site is provided with shared accesses off of both SE Bishop Drive and SE University Avenue. The applicant has provided elevations for the proposed building on the site, which meets the intent of the architectural guidelines within the Site Plan Ordinance. The Planning and Zoning Commissioners, at their meeting, had questions regarding the hours of availability of the proposed vacuums due to noise concerns for the adjacent residential. The applicant has since provided information regarding the hours of the vacuums. The vacuums will only be available during the hours of operation of the car wash, which will be between the hours of 7:30 am – 7:30 pm on the weekdays, with shorter hours on the weekends. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning Commission reviewed this project at the February 23, 2021 Commission Meeting and recommended approval subject to remaining staff comments: Approval of a Site Plan for Shine Shop Carwash (1400 SE University Avenue) Senior City Planner, Melissa DeBoer, introduced the request for approval of a site plan for a car wash as submitted by the applicant, Splash Express, LLC. The subject property is generally located south of SE University Avenue and west of SE Waco Place, Containing approximately 1.10 Acres. Mrs. DeBoer explained that the project includes the construction of a single story car wash building approximately 4,500 square feet in area. Also identified on the site plan are vacuums to the east of the building, vacuum equipment enclosure, a trash enclosure at the southeast corner of the site, and a monument sign proposed at the northwest corner of the site along SE University Avenue. Two accesses are provided to the site off of SE Bishop Drive and SE University Avenue. Both are shared accesses. Five foot wide sidewalks will be installed along SE Bishop Drive and SE University Avenue, J10 and the site will be served with all public utilities. Stormwater detention will be provided with detention basins located at the north and south sides of the site. All parking, landscaping, open space, and lighting ordinance requirements have been met at this time. Staff would recommend approval of the site plan for Shine Shop Carwash Subject to remaining staff comments.  Commissioner Hoifeldt questioned on the hours of operation. Mrs. DeBoer advised that the proposed hours of operation would be from 7:30am to 7:30pm.  Commissioner Streit questioned if there would be access to the vacuum equipment after hours. The answer was unknown during the meeting, however additional information was offered after the meeting from the applicant that has indicated that the vacuum equipment will only be operational during the listed business hours and shut down over night. Commissioner Hoifeldt moved to approve the site plan for Shine Shop Carwash (1400 SE University Avenue), subject to remaining staff comments. Commissioner Ward seconded the motion. Ayes: Streit, Koshy, Conley, Ward, and Hoifeldt. Nays: None. Motion Carries. STAFF REVIEW AND COMMENT: Staff recommends approval of the site plan subject to remaining staff comments. RECOMMENDATION: Approve the resolution subject to remaining staff comments. ATTACHMENTS: I. Proposed Resolution II. Staff Report III. Site Plan & Elevations PREPARED BY: Melissa DeBoer, Senior Planner REVIEWED BY: THE CITY OF WAUKEE, IOWA RESOLUTION 2021- APPROVING THE SITE PLAN FOR SHINE SHOP CARWASH (1400 SE UNIVERSITY AVENUE) IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Site Plan for Shine Shop Carwash, subject to remaining staff comments on February 23, 2021; AND, WHEREAS, the Site Plan for Shine Shop Carwash is in general conformance with §160 – Site and Building Development Standards Ordinance of the Waukee Municipal Code; AND, WHEREAS, the Site Plan for Shine Shop Carwash is in general conformance with §161 – Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND, NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 1st day of March, 2021 that the Site Plan for Shine Shop Carwash is approved subject to remaining staff comments. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Anna Bergman R. Charles Bottenberg Chris Crone Larry R. Lyon Ben Sinclair PLANNING AND ZONING COMMISSION STAFF REPORT PROJECT: Shine Shop Carwash – Site Plan PREPARED BY: Melissa DeBoer, AICP – Senior Planner REPORT DATE: February 19, 2021 MEETING DATE: February 23, 2021 GENERAL INFORMATION Owner: Hawthorne Pointe, LLC Applicant: Splash Express, LLC Owner’s Representative: Roger Silver, Nilles Associates Request: The applicant is requesting approval of a site plan for a car wash. Location and Size: Property is generally located south of SE University Avenue and west of SE Waco Place, containing approximately 1.10 acres. Property Address: 1400 SE University Avenue AREA MAP ABOVE: Aerial of Property identifying the proposed plat (outlined in BLUE). February 19, 2021 2 of 3 LAND USES AND ZONING Location Existing Land Use Comprehensive Plan Current Zoning Property in Question Vacant – Undeveloped Community Commercial C-1 / PD-1 (Community and Highway Service Commercial District / Planned Development District) North Multi-Family Residential / Single Family Residential High Density Residential / Single Family Residential R-3 / PD-1 (Multi-Family Residential District / Planned Development District); C-4 / PD-1 (Office Park Commercial District / Planned Development District); R-2 / PD-1 (One and Two Family Residential District / Planned Development District) South Apartments / Townhomes Medium Density Residential C-1 / PD-1 (Community and Highway Service Commercial District / Planned Development District) East Vacant – Undeveloped Community Commercial C-1 / PD-1 (Community and Highway Service Commercial District / Planned Development District) West Commercial Community Commercial C-1 / PD-1 (Community and Highway Service Commercial District / Planned Development District) PROJECT DESCRIPTION The project includes the construction of a single-story car wash building. The building is proposed to be about 4,500 square feet in area. The site plan also identifies vacuums to the east of the proposed building, a vacuum equipment enclosure at the east side of the site and a trash enclosure at the southeast corner of the site. A monument sign is proposed at the northwest corner of the site, along SE University Avenue. ACCESS AND PARKING There are two accesses into this site from the public streets. One is located to the south off of SE Bishop Drive and the other access is located to the north off of SE University Avenue. Both accesses are shared accesses. A total of 2 parking spaces and 4 queuing spaces are required for the carwash. The total amount of parking proposed is 4 parking spaces and 8 queuing spaces. The proposed site plan meets the parking requirements. SIDEWALKS/TRAILS Five foot wide sidewalks will be installed along SE Bishop Drive on the south and SE University Avenue on the north. February 19, 2021 3 of 3 UTILITIES This site will be serviced with all public utilities. Water and sanitary sewer will be brought in from the mains located to the south along SE Bishop Drive. Storm water detention will be provided with detention basins located at the north and south sides of the site. LANDSCAPING & OPEN SPACE A minimum of 15% of the project area is required to be open space. The total amount of open space proposed is 44%. The landscape plan meets the requirements of the Landscape and Open Space Ordinance and the Kettlestone Design Guidelines. ELEVATIONS The elevations of the building are proposed to be constructed mostly of stone, stucco, metal and transparent overhead doors. MISCELLANEOUS: The applicant has submitted a photometric plan and associated light fixture cut sheets. The lighting plan meets the lighting requirements of the Site Plan Ordinance. COMPREHENSIVE PLAN The comprehensive plan classifies the subject property as Community Commercial. The Community Commercial classification provides a variety of uses that would serve the community and are located along minor or major arterials. STAFF RECOMMENDATION The site plan is in general conformance with the Site Plan Ordinance and Comprehensi ve Plan. Staff recommends approval of the site plan for Shine Shop Carwash subject to remaining staff comments. SHINE SHOP CARWASH - COVE AT KETTLESTONE PLAT 3 WAUKEE, IOWA SITE PLAN NAI #20216 CONSTRUCTION SCHEDULE SITE GRADING UTILITY INSTALLATION BUILDING & PAVING INSTALLATION LANDSCAPING FINISHED GRADING SPRING 2021 SPRING 2021 SPRING 2021 - FALL 2021 SPRING 2021 - FALL 2021 SPRING 2021 - FALL 2021 PROJECT SUMMARY LEGAL DESCRIPTION CURRENT LAND OWNER HAWTHORNE POINTE, LLC 9500 UNIVERSITY AVE, #2112 WEST DES MOINES, IOWA 50266 JARED JOHNSON jjohnson@accuratedevelopment.com OWNER / DEVELOPER BUILDER KEEN PROJECT SOLUTIONS, LLC 3001 SE CONVENIENCE BLVD., SUITE 101 ANKENY, IOWA 50021 MATTHEW FRANDSEN 515-360-6784 CV-1, DP-1, GR-1, LS-1, DT-1 I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM PROFESSIONAL LANDSCAPE ARCHITECT UNDER THE LAWS OF THE STATE OF IOWA. SIGNATURE DATE PAGES OR SHEETS COVERED BY THIS SEAL: LICENSE EXPIRES: 6-30-2021 ROGER J. SILVER SIO TS ROE SFP RAN L EPCSADNA HCTICETROGER J. 327 NO. SILVER ARCHITECT LANDSCAPE FEATO W IO A AL CERTIFICATIONS ILL P . ECN N S E RORSUVEYD E SNHO RPSI OSOFELJ I12106 L&A EIN E R N N A L E GN AI0W DI HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF IOWA. SIGNATURE: NAME: JOHN P. NILLES, P.E. & L.S. NO. 12106 DATE MY LICENSE RENEWAL DATE IS DECEMBER 31, 2020 PAGES OR SHEETS COVERED BY THIS SEAL :CV-1, DP-1, UP-1, DT-1 1.BURY BOLT ON THE SOUTH SIDE OF BISHOP DRIVE, IN FRONT OF UNIT #1356 ELEVATION = 1061.01' 2.CUT "X" ON SOUTH CURB OF SE UNIVERSITY AVE., 20' +/- NORTH OF POWER POLE, 120' +/- WEST OF CURB INTAKE . ELEVATION = 1058.55' BENCHMARKS GENERAL NOTES EXISTING UTILITY NOTE SPECIFICATION REFERENCE THE CITY OF WAUKEE STANDARD SPECIFICATIONS AND THE 2021 IOWA SUDAS STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS SHALL APPLY TO ALL ASPECTS OF CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY IOWA ONE CALL NO LESS THAN 48 HRS. IN ADVANCE OF ANY DIGGING OR EXCAVATION. WHERE PUBLIC UTILITY FIXTURES ARE SHOWN AS EXISTING ON THE PLANS OR ENCOUNTERED WITHIN THE CONSTRUCTION AREA, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE OWNERS OF THOSE UTILITIES PRIOR TO THE BEGINNING OF ANY CONSTRUCTION. THE CONTRACTOR SHALL AFFORD ACCESS TO THESE FACILITIES FOR NECESSARY MODIFICATION OF SERVICES. UNDERGROUND FACILITIES, STRUCTURES AND UTILITIES HAVE BEEN PLOTTED FROM AVAILABLE SURVEYS AND RECORDS, AND THEREFORE THEIR LOCATIONS MUST BE CONSIDERED APPROXIMATE ONLY. IT IS POSSIBLE THERE MAY BE OTHERS, THE EXISTENCE OF WHICH IS PRESENTLY NOT KNOWN OR SHOWN. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THEIR EXISTENCE AND EXACT LOCATION AND TO AVOID DAMAGE THERETO. NO CLAIMS FOR ADDITIONAL COMPENSATION WILL BE ALLOWED TO THE CONTRACTOR FOR ANY INTERFERENCE OR DELAY CAUSED BY SUCH WORK. 1. ONE WEEK PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY PROJECT ENGINEER AND: A. CITY OF WAUKEE 2. ALL MATERIALS AND CONSTRUCTION RELATED TO WORK CONDUCTED AS PART OF THESE PLANS SHALL BE IN ACCORDANCE WITH THE CITY OF WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND THE 2021 STATEWIDE URBAN DESIGN AND SPECIFICATIONS (SUDAS), AND DETAILS SHOWN ON THIS PLAN UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR, REMOVAL, REPLACEMENT, OR REINSTALLATION OF ANY ITEM, BOTH ON- AND OFF-SITE, ADVERSELY AFFECTED BY FAILURE TO FOLLOW SAID SPECIFICATIONS, REPORTS, AND PLANS. 3. CONTRACTOR IS RESPONSIBLE TO UNDERSTAND THE INTENT OF THE WORK TO BE COMPLETED AND TO ADDRESS ANY QUESTIONS, CONCERNS, CONFLICTS, DISCREPANCY OR OTHER ISSUES THAT MAY AFFECT CONSTRUCTION WITH OWNER AND ENGINEER AT LEAST ONE WEEK PRIOR TO COMMENCING CONSTRUCTION. OWNER AND ENGINEER SHALL RESPOND IN A TIMELY MANNER TO ALLOW CONSTRUCTION TO PROCEED. 4. CONTRACTOR SHALL NOTIFY OWNER AND ENGINEER IMMEDIATELY OF ANY ISSUE ENCOUNTERED DURING CONSTRUCTION THAT MAY AFFECT PROPOSED DESIGN. OWNER AND ENGINEER SHALL RESPOND IN A TIMELY MANNER TO ALLOW CONSTRUCTION TO PROCEED. 5. ALL WORK SHALL BE IN ACCORDANCE WITH OSHA CODES AND STANDARDS. NOTHING INDICATED ON THESE PLANS SHALL RELIEVE THE CONTRACTOR FROM COMPLYING WITH ANY APPROPRIATE SAFETY REGULATIONS. 6. THE CONTRACTOR SHALL FIELD VERIFY THE EXACT LOCATION AND ELEVATION OF, AND PROTECT ALL UTILITIES AND STRUCTURES. DAMAGE TO UTILITIES AND STRUCTURES SHALL BE REPAIRED BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE TO THE SATISFACTION OF THE OWNER. 7. THE CONTRACTOR SHALL COORDINATE ALL TIE-INS TO EXISTING UTILITIES WITH THE CITY OF WAUKEE ENGINEERING DEPARTMENT. THE CITY OF WAUKEE ENGINEERING DEPARTMENT SHALL WITNESS ALL TIE-INS. 7. THE CONTRACTOR SHALL PROTECT ALL EXISTING PAVEMENT, SIDEWALKS, TREES, LIGHT POLES AND OTHER EXISTING FEATURES. DAMAGE TO ANY EXISTING FEATURE SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE TO THE SATISFACTION OF THE OWNER. 8. THE CONTRACTOR SHALL PROTECT STORM SEWER AND DRAINAGE WAYS FROM ALLOWING CONCRETE SLURRY TO DISCHARGE OFFSITE DURING CONSTRUCTION OPERATIONS. 8. THE CONTRACTOR SHALL RECONNECT ALL FIELD TILE AND STORM DRAINS DISTURBED DURING CONSTRUCTION. RECONNECTIONS SHALL BE CONSIDERED INCIDENTAL TO PROJECT COST. NOTIFY CITY OF WAUKEE AND NILLES ASSOCIATES PRIOR TO RECONNECTION SO THAT LOCATION OF RECONNECTION CAN BE DOCUMENTED AND INCLUDED ON RECORD DRAWINGS. REPAIRS TO TILE LINES ARE TO BE VERIFIED BY CITY OF WAUKEE PERSONNEL. 9. DETAILS AND NOTES INCLUDED WITHIN THESE PLANS SHALL BE USED FOR CONSTRUCTION. FOR ITEMS WITH NO DETAILS OR NOTES INCLUDED WITHIN THIS PLANS SET, FOLLOW SUDAS DETAILS AND SPECIFICATIONS FOR MATERIALS AND CONSTRUCTION. 10. CONTRACTOR SHALL VERIFY ALL MEASUREMENTS SHOWN ON THE PLANS PRIOR TO CONSTRUCTION. IF ANY DISCREPANCY IS FOUND, NOTIFY ENGINEER IMMEDIATELY BEFORE PROCEEDING. 11. COORDINATE ALL WORK ACTIVITIES WITH ANY OTHER CONSTRUCTION PROJECTS IN THE AREA. 12. ANY DAMAGE TO PROPERTY THAT OCCURS AS A RESULT OF THE CONTRACTOR'S ACTIVITIES OR ACTIONS SHALL BE REPAIRED AND RESTORED IN KIND. PAVEMENT REPLACEMENT SHALL COMPLY WITH WAUKEE STANDARD SPECIFICATIONS. 13. THE CONTRACTOR SHALL PROTECT AND/OR PROVIDE SUPPORT TO UTILITY POLES NEAR CONSTRUCTION ACTIVITIES AS REQUIRED. 14. PROVIDE TO THE PROJECT ENGINEER, ALL SHOP DRAWINGS FOR MATERIALS INCORPORATED IN THE WORK SUPPLIED BY THE CONTRACTOR. 15. THE CONTRACTOR SHALL FOLLOW THE STORMWATER POLLUTION PREVENTION PLAN PREPARED FOR THIS SITE. 16. CONTRACTORS ON-SITE SHALL BE RESPONSIBLE FOR DAILY CLEAN-UP OF SEDIMENT AND DEBRIS TRACKED OR WASHED ONTO PUBLIC RIGHTS-OF-WAY AND AREAS OUTSIDE PROJECT LIMITS AT THE END OF EACH WORK DAY AND PRIOR TO A RAIN EVENT. 17. DURING THE PROGRESS OF THE WORK, IF SUBSURFACE OR LATENT PHYSICAL CONDITIONS ARE ENCOUNTERED AT THE SITE DIFFERING MATERIALLY FROM THOSE INDICATED ON THE PLANS OR IF UNKNOWN PHYSICAL, CULTURAL, AND/OR ENVIRONMENTAL CONDITIONS OF AN UNUSUAL NATURE ARE ENCOUNTERED AT THE SITE, THE PARTY DISCOVERING SUCH CONDITIONS SHALL PROMPTLY NOTIFY THE CITY OF WAUKEE, AND THE ENGINEER (NILLES ASSOCIATES/515-965-0123) BEFORE THE SITE IS FURTHER DISTURBED. 18. ALL STAKING INCLUDING STAKING OF PEDESTRIAN FACILITIES SHALL BE PERFORMED UNDER THE DIRECTION OF A LICENSED ENGINEER OR LAND SURVEYOR. 19. ANY CHANGES MADE TO THE PROPOSED DRAWINGS DURING CONSTRUCTION SHALL BE APPROVED IN WRITING BY THE CITY OF WAUKEE DEVELOPMENT SERVICES DEPARTMENT PRIOR TO CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR ANY CHANGES MADE DURING CONSTRUCTION THAT HAVE NOT BEEN GRANTED APPROVAL BY THE CITY OF WAUKEE DEVELOPMENT SERVICES DEPARTMENT. LEGEND Existing / Proposed Existing / Proposed MW WELL E EM E TR GM TR TB W C TV AC GV WV YH WSO HH S D MW WELL E EM E TR GM TR TB W CO C TV AC GV WV YH WSO HH DSDS Round iron rebarIR Round iron pipeIP Portland cement concrete Asphaltic cement concrete Pipe flowline elevation Reinforced concrete pipe Corrugated metal pipe Corrugated plastic pipe Polyvinyl chloride pipe Cast iron pipe Subject boundary line Section line Existing easement line Barbed wire fence line Chain-link fence line Silt fence Sanitary sewer & size Storm sewer and size Water main and size Gas main & size Overhead electric & wires Overhead communication Underground electric Underground television Underground communication Contour elevation Swale flowline Edge of water Edge of tree dripline Sanitary sewer manhole Cleanout Storm sewer manhole Storm sewer intake Storm sewer beehive Flared end section Water hydrant Water valve Water service shut-off Water main manhole Monitoring well Yard hydrant Well Gas meter Gas valve Air conditioning unit Electric manhole Electric meter Electric pedestal Electric transformer Utility hand hole Utility pole Utility pole with light Light pole Guy wire Traffic signal Traffic signal with light Traffic manhole Communication pedestal PCC ACC FL RCP CMP CPP PVC CIP SS ST W G OHE OHC UGE TV UGC 900' Telephone booth TV pedestal Billboard sign Street sign Down spout Deciduous tree and trunk diameter Tree shrub Coniferous tree and trunk diameter Spot elevationx 900.0'x 900.0' Address12341234 Proposed boundary line Existing boundary line Future boundary line Proposed easement line Setback line Public utilty easementP.U.E. Public storm sewer easementS.T.S.E. Back of curb to back of curbB/B SF Straw WattleWT Construction limits Construction fence Ground up light Surface water flowage easementS.W.F.E. Public ingress / egress easementI.E.E. Public gas easementG.E. Public sanitary sewer easementS.S.E. MidAmerican Energy Co underground electric line easementM.E.C. Public drainage easementD.E. LOT 2, COVE AT KETTLESTONE PLAT 3, AN OFFICIAL PLAT, LOCATED IN THE CITY OF WAUKEE, DALLAS COUNTY, IOWA. CONTAINING 1.10 ACRES MORE OR LESS. SAID PARCEL IS SUBJECT TO ALL EASEMENTS AND RESTRICTIONS.NOTICE: NILLES ASSOCIATES, INC. WAIVES ANYAND ALL RESPONSIBILITY AND LIABILITY FORPROBLEMS WHICH ARISE FROM FAILURE TOFOLLOW THESE PLANS, SPECIFICATIONS, ANDTHE ENGINEERING INTENT THEY CONVEY, ORFOR PROBLEMS WHICH ARISE FROM FAILURETO OBTAIN AND/OR FOLLOW THE ENGINEER'SGUIDANCE WITH RESPECT TO ANY ERRORS,OMISSIONS, INCONSISTENCIES, AMBIGUITIESOR CONFLICTS WHICH ARE ALLEGED.DATE: DRAWN BY: CHECKED BY: SHEET SIZE: SHEET TITLE: SHEET NO.: NAI NO.:PROJECT NAME:DESCRIPTION:REVISIONS:22" X 34"1250 SW STATE STREET, SUITE AANKENY, IOWA 50023-2555(515) 965-0123 phone - (515) 965-3322 faxCivil Engineering - Land SurveyingLandscape ArchitectureNilles Associates61 JPN BLH 1/12/20217.)6.)5.)4.)3.) REVISIONS PER CITY OF WAUKEE COMMENTS (2/4/2021)2.) REVISIONS PER CITY OF WAUKEE COMMENTS (1/27/2021)1.) REVISIONS PER CITY OF WAUKEE COMMENTS (1/08/2021)20216WAUKEE, IASHINE SHOP CARWASH - COVE AT KETTLESTONE PLAT 3COVER SHEETCV-1 V:\NAI 2017\Projects 2017\20216\dwg\20216-SP.dwg PRELIMINARY - SUBMITTAL #2SCALE: 1" = 1000' VICINITY MAP NORTH SE FLORENCE DRSE PRAIRIE P A R K L N SE ASHTON CT SE PARKVIEW CROSSINGSE PRAIRIE CREEK DRSE FLORENCE DR( WAUKEE / WEST DES MOINES CORPORATE LIMITS )CHALK ST WESTOWN PKWY SIL V E R S T CH A L K S T RED SUNSET DR SE LA GRANT PARKWAY93RD ST89TH STCANYON ST 98TH STCEDARWOOD DR WILSON ST 90TH ST91ST STWEST O W N PKWY SCARLET DR SE TALLGRASS LN 13TH ST INDIGO LNBIRCHWOOD CIR ROSEWOOD DRMANORDRHICKORY CIR SE GREENTREE DRSIL V E R S T CH A L K S T 88TH STSE DRIFTWOOD LN OXFORD DR PLEASANT VIEW DR 80 SE WESTOWN P A R K W A Y ASHWORTH RD ASHWORTH RDGRAND PRAIRIE PARKWAYUNIVERSITY AVE (WAUKEE / WEST DESMOINES CORPORATE LIMITS) UNIVERSITY AVEBOONE DR92ND ST90TH ST96TH ST94TH ST88TH STBISHOP DR GREENSPIRE DR KI N G M A N D R FA I R V I E W D R94TH STLAKE DR 92ND STOLSON DR SOUTHB R A N C H D R BISHOP DRSE BRICK DRSE ALICE RDSE WACO PLSE WACO PLSE WESTWOODS DRNI N E I R O N D R PROJECT SITE FUTURE OWNER / DEVELOPER SPLASH EXPRESS, LLC 801 GRAND AVE. SUITE 3560 DES MOINES, IOWA 50266 JASON DeSTIGTER jdestigter@summitequity.com Sheet List Table SHEET NO.SHEET TITLE DESCRIPTION Sheet Number 1 CV-1 COVER SHEET 1 2 DP-1 DIMENSION PLAN 2 3 GP-1 GRADING PLAN 3 4 UP-1 UTILITY PLAN 4 5 LS-1 LANDSCAPE PLAN 5 6 DT-1 DETAIL SHEET 6 SITE ADDRESS:1400 SE UNIVERSITY AVENUE SITE AREA: 1.10 ACRES (48,002 SF) PROPOSED USE: COMMERCIAL CAR WASH BUILDING INFORMATION: SLAB ON GRADE BLDG. COVERAGE : 4,542 SF PAVING INFORMATION: PROPOSED PAVING INCLUDES ON-SITE DRIVEWAY AND PARKING, ON-SITE SHARED DRIVE BY OTHERS, OFF-SITE SHARED DRIVE, AND SIDEWALK IN RIGHT-OF-WAY. PRIVATE DRIVE & PARKING: 20,776 SF (ON LOT) 3,701 SF (FUTURE SHARED DRIVE ON LOT) 3,546 SF (SHARED DRIVE OFF LOT) SIDEWALK: 2,169 SF (ON LOT) 1,703 SF (R.O.W.) TOTAL IMPERVIOUS SURFACE ON LOT:26,646 SF (56%) MINIMUM OPEN SPACE: 15% OPEN SPACE PROVIDED:48,002 SF - 26,646 SF = 21,356 SF (44%) PROPERTY ZONING: COMMERCIAL DEVELOPMENT AS PART OF THE PD-1 PLANNED DEVELOPMENT OVERLAY DISTRICT (ORDINANCE NO. 2791) BOOK 2016 PAGE 2362 WITH UNDERLYING C-1 COMMUNITY AND HIGHWAY SERVICE COMMERCIAL DISTRICT BULK REGULATIONS: LOT AREA = NONE FRONT YARD = ZERO (0') FEET MINIMUM, NOT MAXIMUM SIDE YARD = NONE, EXCEPT 10 FEET MINIMUM ADJACENT TO RESIDENTIAL PROPERTIES. REAR YARD = NONE, EXCEPT 25 FEET MINIMUM ADJACENT TO RESIDENTIAL PROPERTIES. PARKING: PARKING STALLS REQUIRED: 2 STALLS PARKING STALLS PROVIDED: 4 STALLS (INCLUDING 1 VAN ACCESSIBLE STALL) QUEUING SPACES REQUIRED: 8 SPACES (2 SPACES PER 1,000 SF BUILDING COVERAGE) QUEUING SPACES PROVIDED: 8 SPACES 9.0'7.7'24 ST24 ST24 ST24 ST WV 24 S T 24 ST 24 ST 24 ST 24 ST 24 ST 24 ST 24 ST 24 ST 24 ST 24 ST30 ST30 ST30 ST30 ST 30 ST 30" RCP WITH FESFL=1050.71'UGE-M57E (ML)UGE-M57E (ML)UGE-M57E (ML)OHE-M57EOHE-M57EOHE-M57EUGC-CTLIA01 (M/L)UGC-CTLIA01 (M/L)UGC-CTLIA01 (M/L)UGC-CTLIA01 (M/L)UGF-INS (M/L)UGF-INS (M/L)UGF-INS (M/L)UGF-INS (M/L)UGF-UPN (M/L)UGF-UPN (M/L)UGF-UPN (M/L)UGF-UPN (M/L)8"W (M/L)8"W (M/L)8"W (M/L)8"SS (M/L)8"SS (M/L)8"SS (M/L)UGE-M57E (ML)UGE-M57E (ML)UGF-WKE (M/L)UGF-WKE (M/L)6"SS (M/L)G (M/L)G (M/L)G (M/L)G (M/L)G (M/L)G (M/L)UGF-WINIA (M/L)UGF-WINIA (M/L)UGF-WINIA (M/L)UGF-WINIA (M/L)8"W (M/L) 12.5' 9.0' 8.0'8.0'18.5'18.50'5.0'4.0'6.0'5.0'10.8'5.0' 5.4' 6.91'SE BISHOP DRIVE(70' PUBLIC RIGHT-OF-WAY)SE UNIVERSITY AVENUE(120' PUBLIC RIGHT-OF-WAY)25' B/BEXI S T I N G 31' B / B P C C R3 7 . 0 ' 73.4' 31.2' 5.0' 5.0' 7.0' 15.4' 13.6'86.1'13.1'15.5' PROPOSED 25' INGRESS/EGRESS EASEMENT 36.8'S89°48'03"E 172.33'S0°11'55"W 301.59'132.84'R=285.00'Δ=26°42'24"N89°48'05"W 44.24'N0°11'55"E 271.18'4.0'25' B/B 25' B/B 5.8'11.0'10'EXISTING 10' PUBLICUTILITY EASEMENT(BOOK 2015 PAGE 20833)EXISTING 30' PUBLIC INGRESS / EGRESS EASEMENT BOOK 2020 PAGE 22559)20'EXISTING 20' STORM SEWER EASEMENT (BOOK 2015 PAGE 20833) LOT 3 COVE AT KETTLESON PLAT 3 10'EXISTING 10' PUBLICUTILITY EASEMENT(BOOK 2019 PAGE 21475) &EXISTING 10' SANITARYSEWER EASEMENT(BOOK 2019 PAGE 20833)LOT 2 COVE AT KETTLESON PLAT 3 LOT 1 COVE AT KETTLESON PLAT 3 3.2'10.4'6.0'6.0' PROPOSED 37' INGRESS/EGRESS EASEMENT OUTLOT Z COVE AT KETTLESTONE PLAT 1PROPOSED 25' INGRESS/EGRESS EASEMENT PROPOSED 21.2' STORM WATER MANAGEMENT FACILITY MAINTENANCE COVENANT AND PERMANENT EASEMENT 5.0'7.0'7.3'24.6'10.0'R2 . 5 ' 31.2' 25' B/B 25.0'13.1' 13.1'12.5'18.5'18.1' R15. 0' R 3 . 0 '15.5'63.7'16.3'38.8' 12.5' 19.4' 13.1'12.5'13.1' 13.3'R1 4 . 4 ' 9.0' 9.6' R15 . 0 ' 3.0' 12' PROPOSED ELECTRIC EASEMENT 113.1' 3 5 . 6 '24.3'1 6 . 0 'R16.0'R31. 8' R4.0' R8. 0 '6.0'11.0'5.0'9.0' 2.7' 13.1'12.5'12.5'12.5'12.5'12.5'13.1'4.0'18.2'R1 5 . 0 'R22.1'29.6'92.8'R4.0'R4.0'8.3'23.3'36.0'5.0'5.0'7.1'7.0'5.0'5. 0 ' R 2 5 . 0 ' R25.0'R50.0'36.0'14.7'105.0'5.5' 14.0'14.0'R1 2 . 0 ' 1.0' 21.2' 5.00'PROPOSED 27' x 150'TEMPORARY EASEMENT0 SCALE 1020 NORTH NOTICE: NILLES ASSOCIATES, INC. WAIVES ANYAND ALL RESPONSIBILITY AND LIABILITY FORPROBLEMS WHICH ARISE FROM FAILURE TOFOLLOW THESE PLANS, SPECIFICATIONS, ANDTHE ENGINEERING INTENT THEY CONVEY, ORFOR PROBLEMS WHICH ARISE FROM FAILURETO OBTAIN AND/OR FOLLOW THE ENGINEER'SGUIDANCE WITH RESPECT TO ANY ERRORS,OMISSIONS, INCONSISTENCIES, AMBIGUITIESOR CONFLICTS WHICH ARE ALLEGED.DATE: DRAWN BY: CHECKED BY: SHEET SIZE: SHEET TITLE: SHEET NO.: NAI NO.:PROJECT NAME:DESCRIPTION:REVISIONS:22" X 34"1250 SW STATE STREET, SUITE AANKENY, IOWA 50023-2555(515) 965-0123 phone - (515) 965-3322 faxCivil Engineering - Land SurveyingLandscape ArchitectureNilles Associates62 JPN BLH 1/12/20217.)6.)5.)4.)3.) REVISIONS PER CITY OF WAUKEE COMMENTS (2/4/2021)2.) REVISIONS PER CITY OF WAUKEE COMMENTS (1/27/2021)1.) REVISIONS PER CITY OF WAUKEE COMMENTS (1/08/2021)20216WAUKEE, IASHINE SHOP CARWASH - COVE AT KETTLESTONE PLAT 3DIMENSION PLANDP-1 V:\NAI 2017\Projects 2017\20216\dwg\20216-SP.dwg PRELIMINARY - SUBMITTAL #2PAVING NOTES DIMENSION PLAN NOTES 1.PARKING LOT AND DRIVE AISLE PAVING SHALL BE NON-REINFORCED P.C.C. WITH 7" THICKNESS. 2.PAVING WITHIN PUBLIC STREET RIGHT-OF-WAY SHALL BE A MINIMUM OF 8" NON-REINFORCED P.C.C. 3.TRASH ENCLOSURE PAD SHALL BE NON-REINFORCED P.C.C. WITH A MINIMUM THICKNESS OF 8". 4.ALL PAVING SHALL COMPLY W/ SUDAS SECTION 7010 FOR MATERIALS AND INSTALLATION. 5.COMPLY WITH SUDAS SECTION 7030 FOR P.C.C. SIDEWALKS MATERIALS AND INSTALLATION. 6.REFER TO ARCHITECTURAL PLAN FOR ADDITIONAL INFORMATION ON STOOPS AND SIDEWALKS ADJACENT TO BUILDING. 7.SIDEWALKS ADJACENT TO ROLLED CURB PORTION OF PRIVATE STREETS AND PUBLIC SIDEWALK RAMPS SHALL BE NON-REINFORCED P.C.C. WITH A MINIMUM THICKNESS OF 6 INCHES. ALL OTHER SIDEWALKS AND RAMPS SHALL HAVE A MINIMUM THICKNESS OF 4 INCHES. 8.ALL TRUNCATED DOME INSERTS FOR 5' SIDEWALK SHALL BE CAST IRON WITH NATURAL FINISH BY ADA SOLUTIONS, OR APPROVED EQUAL. GENERAL DIMENSION PLAN NOTES ·BUILDING DIMENSIONS ARE SHOWN FOR CONTRACTOR CONVENIENCE ONLY-REFER TO ARCHITECTURAL PLAN FOR BUILDING DIMENSIONS. SIDEWALK LEGEND RAMP TURNING SPACE MAX 1.5% IN ALL DIRECTIONS SPECIAL SHAPING A.PROPERTY LINE. B.VAN ACCESSIBLE STALL SIGN IN ACCORDANCE WITH ANSI A117.1-09 SECTION 502.7, MOUNTED ON BUILDING. C.PAINT STRIPING. D.6" STANDARD CURB PER SUDAS FIGURE 7010.102 E.CLASS A SIDEWALK CURB (SUDAS FIGURE 7030.202 - DETAIL 3). F.CURB CHANGES FROM 6" STANDARD TO (SUDAS FIGURE 7010.102) TO THICKENED EDGE CLASS A SIDEWALK CURB (SUDAS FIGURE 7030.202 - DETAIL 3). G.CURB CHANGES FROM CLASS A SIDEWALK CURB (SUDAS FIGURE 7030.202 - DETAIL 3) TO 4" SLOPED CURB (SUDAS FIGURE 7010.102 - DETAIL 3). H.4" SLOPED CURB (SUDAS FIGURE 7010.102 - DETAIL 3). I.NO CURB THROUGH THIS AREA. J.TAPER CURB. K.3' CONCRETE FLUME TO CONVEY STORM OVERFLOW FROM WEST. L.TRASH ENCLOSURE LOCATION. REFER TO ARCHITECTURAL PLANS FOR DETAILS. M.GRIND / REMOVE 70 LF CONCRETE CURB ALONG STREET. N.COORDINATE WITH CONTRACTOR ON ADJACENT SITE TO INSTALL 6" CURB ALONG EDGE OF DRIVE. O.CENTRAL VACUUM EQUIPMENT ENCLOSURE. P.KIOSK STAND & CANOPY - SEE ARCHITECTURAL PLANS FOR DETAILS. Q.PROTECTION BOLLARD. R."DO NOT ENTER" SIGN MOUNTED ON BOLLARD. S.MONUMENT SIGN - SEE ARCHITECTURAL PLANS FOR DETAILS. T.ENTRANCE GATES. U.LIGHT POLE. V.TRANSFORMER. W.WHEEL STOP. X.PEDESTRIAN RAMP WITH TRUNCATED DOME DETECTABLE WARNINGS. MAXIMUM SLOPE 8.33% - DESIGNED SLOPE = 6.25% - 1.5% CROSS SLOPE. Y.FRONT, SIDE AND REAR YARD SETBACKS ALL EQUAL TO ZERO FEET PER THE COVE AT KETTLESTONE PD AMENDMENT. Z.VACUUM EQUIPMENT LOCATED AT EACH VACUUM BAY. WHEN VACUUM IS ADJACENT TO SIDEWALK, ALIGN EDGE OF CLASS A SIDEWALK CURB WITH CENTERLINE OF VACUUM COLUMN. CONSULT MECHANICAL PLANS FOR EXACT SIZE AND LOCATION OF ALL VACUUM EQUIPMENT. AA.VEHICLE QUEUING SPACES SHOWN AS 12' X 20' PER CHAPTER 168 OF THE CITY OF WAUKEE ZONING REGULATIONS AB.INFILTRATION TRENCH. REFER TO DETAILS D-1 AND D-2 ON SHEET DT-1 FOR FURTHER INFORMATION. AC.BUILDING HEIGHT = 25' - 0"" AD.PROPOSED STORM WATER MANAGEMENT FACILITY MAINTENANCE COVENANT AND PERMANENT EASEMENT. AE.STOP/GO SIGN AT CARWASH EXIT. REFER TO MECHANICAL PLANS FOR FURTHER DETAILS AND DIMENSIONS. AF.SNOW MELT MANIFOLD. REFER TO MECHANICAL PLANS FOR FURTHER DETAILS AND DIMENSIONS. AG.IRRIGATION CONTROL BOX. REFER TO MECHANICAL PLANS FOR FURTHER DETAILS AND DIMENSIONS. AH.PCC PAVING WITH RADIANT HEATING FOR SNOW MELT SYSTEM. ADD UNDER SLAB INSULATION AS DIRECTED BY MEP DRAWINGS. REFER TO MEP DRAWINGS FOR FURTHER DETAILS. AI.ACCESSIBLE PARKING STALL. A AB C D D E E E G L I M N O P Q R S T UW V XPROTECTION BOLLARDP-2 NOT TO SCALE A B 8" DIAMETER STEEL BOLLARD FILLED WITH CONCRETE AND COVERED WITH LDPE THERMOPLASTIC BUMPER POST SLEEVE SUCH AS IDEAL SHIELD 1 4" DOME TOP BOLLARD COVER #BPD-BL-04-060-S OR APPROVED EQUAL. FOLLOW MANUFACTURERS RECCOMENDATIONS FOR INSTALLTION AND MOUNTING.60" MINIMUMA B FINISHED GRADE A A D I D E I F C C U C C C D F D D D C UZ Z AA 1 1 1 1 1 1 1 1 1 2 3 I AB E E D AD AD AD AF AE AFAG Q Q U U AH AHII H H D AI J J K K J 8"W NGAS SVC 4"SS6"SS2"W 24 ST24 ST24 ST24 ST WV 24 S T 24 ST 24 ST 24 ST 24 ST 24 ST 24 ST 24 ST 24 ST 24 ST 24 ST30 ST30 STUGE-M57E (ML)UGE-M57E (ML)UGE-M57E (ML)OHE-M57EOHE-M57EOHE-M57EUGC-CTLIA01 (M/L)UGC-CTLIA01 (M/L)UGC-CTLIA01 (M/L)UGF-INS (M/L)UGF-INS (M/L)UGF-INS (M/L)UGF-UPN (M/L)UGF-UPN (M/L)UGF-UPN (M/L)8"W (M/L)8"W (M/L)8"W (M/L)8"SS (M/L)8"SS (M/L)8"SS (M/L)UGE-M57E (ML)UGE-M57E (ML)UGF-WKE (M/L)UGF-WKE (M/L)6"SS (M/L)G (M/L)G (M/L)G (M/L)G (M/L)G (M/L)UGF-WINIA (M/L)UGF-WINIA (M/L)UGF-WINIA (M/L)8"W (M/L)SE BISHOP DRIVE(70' PUBLIC RIGHT-OF-WAY)SE UNIVERSITY AVENUE(120' PUBLIC RIGHT-OF-WAY)SFWTSFWTWTWTWTWTWTWTWTWTWTWTWTWT WT WT WTWTLOT 3 COVE AT KETTLESON PLAT 3 LOT 2 COVE AT KETTLESON PLAT 3 LOT 1 COVE AT KETTLESON PLAT 3 OUTLOT Z COVE AT KETTLESTONE PLAT 1??? (S)1060.17 (S)1059.9 5 ( S ) 1060.04 ( S ) WTWT 2.0%33.3%33.3%33. 0 % 25.0% 25.0%25.0%0.9%2.3%0.3%15.8%2.7%1.3%0.2%5.9% 10 5 9 . 9 1 ( S )1059.88 (S)1059. 6 5 ( S ) 1059.77 (S)1060.27 (TC) 1060.53 (S) 10 6 0 . 4 6 ( S ) 1060. 4 6 ( S)1060.66 (TC)1060.65 (TC)1060.41 (TC)1060.19 (TC)1059.99 (TC)1060.54 (TC)1 0 5 9 . 9 2 (S )1060.04 (S) 105 9. 8 6 ( T C) 1059.33 (TC) 1 0 6 0 . 8 8 ( T C ) 1060. 4 1 ( S) 106 0. 8 1 ( T C) 106 0. 7 1 ( T C) 106 0 . 8 4 ( T C )1060.88 (TC)1060.88 (TC)1060. 4 2 ( T C ) 1061.00 (TC) 1059. 7 0 ( T C)1057.62 (TC)1059.00 (TC)1057.59 (TC)1059.93 (TC)1061.07 (TC) 106 1 . 2 8 ( T C ) 1060 . 1 1 ( T C ) 1060. 1 9 ( S) 10 6 0 . 2 1 ( S ) 1060. 3 8 ( S) 106 0 . 4 0 ( S ) 10 6 1 . 1 0 ( S ) 1061. 1 2 ( S) 10 6 0 . 8 1 ( T C )APPROVED1060' CONTOURAPPROVED1061' CONTOURAPPROVED 1062' CONTOUR 1060. 0 0 ( S) 1059.65 (S )1058.90 (S)1057'1058'1059'1058'1060'1060'1059'1059'1059'1060'1061'1061'1060'1057'1059'1059'1055'1056'1057'1058'1059'10 5 9 ' 1059' 1060' 1060' 1061' 1061'1060'1060'1059'1060'1 0 6 0 '1060'1058'1059'1 0 5 9 ' 1058'1058'1059'1059' 1060' 1060' 1060'1055'1060'1056'1057'1058'1059'1059.76 (TC)1059.67 (TC)1060.17 (S)1060.27 (S)1060.33 (TC)1060.46 (TC) 1060. 8 1 ( T C ) 1060.41 ( T C ) 1060.57 (TC) 1060.29 ( T C ) 1060. 5 2 ( T C )1060.54 (S)1060. 5 0 ( S) 1061. 0 0 ( S)1060.40 (TC) 1 0 6 0 . 1 3 ( S ) 10 5 9 . 9 9 ( S ) SF SF 1 0 5 9 . 9 0 ( S ) 10 5 9 . 8 3 ( S ) 1060.12 (TC) 1060. 0 0 ( S ) 1059.65 (S ) WT WT G (M/L)G (M/L)1059'1060'1059'1.5%1.5%1. 4 % 1. 4 %6.2%6.2%1. 3 %6.3%6.2%1.6 % 1. 5 %1.5%1.5%1. 5 % 1060. 1 9 ( T C)1060.11 (TC)1059.69 (S)1059.61 (S)10 6 0 . 0 5 ( S ) 10 6 0 . 1 2 ( S ) 1 0 6 0 . 1 9 ( S ) 10 6 0 . 1 3 ( S )1059.48 (S)1059.98 ( T C )1059.56 (S)1060.06 (TC)10 5 9 . 5 5 ( S ) 10 5 9 . 9 9 ( S ) 10 5 9 . 9 2 ( S ) 106 0 . 0 6 ( S ) 10 5 9 . 9 9 ( S ) 1. 5 %4"SSWT 3.5%3.2%1.6% 0.6%0.0%0.0%0.5% 1060. 9 6 ( T C)1060.46 (S)1060.54 (S)1 0 6 1 . 0 4 (TC ) 1 0 6 0 . 9 7 (S ) 1060.84 (S )1060.87 (S) 1060 . 8 5 ( S ) 1060. 8 7 ( S ) 3.6% 3.6%1.5%1.5%0.5% 0.0%1.1%1060.45 (TC)1060.54 (S )1060.87 (S )1060.87 (S )1060.80 (TC)1060.77 (TC)1060.41 (S)1060.39 (S)1 0 6 0 . 5 3 ( S )1060.46 (S ) 1.5% 0.2%1.3%0.6% 0.4%1.5%10 6 0 . 7 8 ( S ) 1 0 6 0 . 8 6 ( S ) 106 0 . 8 6 ( S ) 1060.87 (S)0.2%1.5%1.4%0.2% 0.0%2"W 106 1. 0 4 ( S)1060.76 (S)1060.63 (TC)1060.84 (TC) 1060.70 (S)1060.70 (S)1060.61 (S )1060.61 (S)1061.04 (S)1060.76 (S)1060.67 (S)1060.67 (S)1060.84 (TC)1060.84 (TC)1060.91 (S)1060.87 (S)1060.84 (TC)1060.53 (TC)1060.6 2 ( S)1060.45 (TC)1060.54 (S)1060.49 (TC)106 0 . 6 8 ( S ) 106 0 . 5 8 ( S )1.3%1.2% 1.5%1.4%1.2% 1.1%1.6%1.6%0.5%0.0% 0.0%0.5%3.0% 3.5%1.5%1.5%1060.84 (TC)0.5%0.0%0.5% 0.0% 1060. 8 4 ( T C) 106 0. 8 4 ( T C)1060.41 (TC)1060.94 (S)1061.04 (S)0.5%0.0%0.5% 0.0%NOTICE: NILLES ASSOCIATES, INC. WAIVES ANYAND ALL RESPONSIBILITY AND LIABILITY FORPROBLEMS WHICH ARISE FROM FAILURE TOFOLLOW THESE PLANS, SPECIFICATIONS, ANDTHE ENGINEERING INTENT THEY CONVEY, ORFOR PROBLEMS WHICH ARISE FROM FAILURETO OBTAIN AND/OR FOLLOW THE ENGINEER'SGUIDANCE WITH RESPECT TO ANY ERRORS,OMISSIONS, INCONSISTENCIES, AMBIGUITIESOR CONFLICTS WHICH ARE ALLEGED.DATE: DRAWN BY: CHECKED BY: SHEET SIZE: SHEET TITLE: SHEET NO.: NAI NO.:PROJECT NAME:DESCRIPTION:REVISIONS:22" X 34"1250 SW STATE STREET, SUITE AANKENY, IOWA 50023-2555(515) 965-0123 phone - (515) 965-3322 faxCivil Engineering - Land SurveyingLandscape ArchitectureNilles Associates63 JPN BLH 1/12/20217.)6.)5.)4.)3.) REVISIONS PER CITY OF WAUKEE COMMENTS (2/4/2021)2.) REVISIONS PER CITY OF WAUKEE COMMENTS (1/27/2021)1.) REVISIONS PER CITY OF WAUKEE COMMENTS (1/08/2021)20216WAUKEE, IASHINE SHOP CARWASH - COVE AT KETTLESTONE PLAT 3GRADING PLANGP-1 V:\NAI 2017\Projects 2017\20216\dwg\20216-SP.dwg PRELIMINARY - SUBMITTAL #2B C E F GG HA.PROVIDE SILT FENCE AND 9" STRAW WATTLES WHERE SHOWN FOR EROSION CONTROL MEASURES. LINES MARKED -----SF----- AND ----WT---- RESPECTIVELY. 179 LF OF SILT FENCE SHOWN. 729 LF OF WATTLE SHOWN. INSTALL PER SUDAS 9040. B.CONSTRUCTION ENTRANCE - 16' WIDE X 60' LONG X 12'' DEPTH STONE . C.CONCRETE WASHOUT AREA. D.INSTALL AND MAINTAIN INLET CONTROL DEVICE PRIOR TO AND FOLLOWING PAVEMENT INSTALLATION E.SOUTH BASIN 100-YEAR WATER ELEVATION = 1058.62 F.NORTH BASIN 100-YEAR WATER ELEVATION = 1058.29 G.CONSTRUCT CONCRETE FLUME BETWEEN CURBS TO ALLOW STORMWATER TO FLOW TO BASIN. SEE ELEVATION POINTS LISTED ON THIS SHEET. H.INSTALL 4' x 8' SECTION OF FLEXAMAT ARMORMAT WITH DETENTION BASIN SEED MIXTURE AT PIPE OUTLET. REFER TO MANUFACTURERS GUIDES FOR INSTALLATION PROCEDURES. I.TOP SOIL STOCKPILE LOCATION. J.S203 100-YR WATER ELEVATION = 1059.35. OVERFLOW ELEVATION = 1059.43. K.S202 100-YR WATER ELEVATION = 1059.96. OVERFLOW ELEVATION = 1060.04. L.S201 100-YR WATER ELEVATION = 1058.83. OVERFLOW ELEVATION = 1058.83. M.S402 100-YR WATER ELEVATION = 1059.74. OVERFLOW ELEVATION = 1059.91. N.S401 100-YR WATER ELEVATION = 1059.74. OVERFLOW ELEVATION = 1060.12 O.BASIN OVERFLOW ELEVATION = 1059.65. OVERFLOW ENTERS STORM SEWER THROUGH EXISTING INTAKE IN STREET ROW. P.BASIN OVERFLOW ELEVATION = 1058.90. INSTALL FLEXAMAT ARMORING AT BASIN OVERFLOW LOCATION. OVERFLOW ENTERS STORM SEWER THROUGH EXISTING FES LOCATED 100 FEET EAST. Q.PROVIDE 4" SLOPED CURB IN MIDDLE OF VACUUM EQUPMENT STATION LEADING TO SLOPED RAMP FOR VACUUM EQUIPMENT ACCESS. R.CURB CUT OPENING LEADING TO "RAIN GUARDIAN TURRET" PRE-TREATMENT STRUCTURE. REFER TO MANUFACTURERS SPECIFICATIONS FOR INSTALLATION INSTRUCTIONS. S.DISTURBANCE BOUNDARY. T.STAGING AND MATERIALS STORAGE LOCATION. INCLUDES COVERED WASTE STORAGE AND PORTABLE TOILET LOCATION. ENSURE PORTABLE TOILET IS STAKED AND LOCATED IN AN APPROVED LOCATION ACCORDING TO NPDES GP#2 PERMIT REQUIREMENTS. PROVIDE 4" SLOPED CURB IN MIDDLE OF VACUUM EQUPMENT STATION LEADING TO SLOPED RAMP FOR VACUUM EQUIPMENT ACCESS. GRADING PLAN NOTES GENERAL GRADING PLAN NOTES 1.ALL EXTERIOR PAVING AREAS SHALL HAVE 12" DEPTH SUBGRADE PREPARATION. SCARIFY AND COMPACT PER GEOTECHNICAL REPORT EXTENDING 2' BEYOND PAVING LIMITS. 2.THE CONTRACTOR IS RESPONSIBLE FOR VERIFICATION AND COORDINATION OF ALL SITE UTILITIES. 3.CONTRACTOR TO STRIP AND STOCKPILE TOPSOIL ON ALL AREAS TO BE CUT OR FILLED. RE-SPREAD TO MINIMUM 8" DEPTH TO FINISH GRADES USING ON-SITE PER SUDAS 2010. 4.OWNER IS RESPONSIBLE FOR ALL MAINTENANCE AND UPKEEP OF DETENTION FACILITIES. 5.STABILIZATION OF DISTURBED AREAS MUST, AT A MINIMUM, BE INITIATED IMMEDIATELY WHENEVER ANY CLEARING, GRADING, EXCAVATING OR OTHER EARTH DISTURBING ACTIVITIES HAVE PERMANENTLY CEASED ON ANY PORTION OF THE SITE OR TEMPORARILY CEASED ON ANY PORTION OF THE SITE AND WILL NOT RESUME FOR A PERIOD EXCEEDING 14 CALENDAR DAYS. PRIOR TO PAVING: PROVIDE TEMPORARY STABILIZATION FOR 1.10 ACRES. ACCEPTABLE FORMS OF TEMPORARY STABILIZATION INCLUDE TEMPORARY SEEDING, MULCHING, GEO-TEXTILES, AND SURFACE ROUGHENING. AFTER PAVING: PROVIDE STABILIZATION FOR 0.39 ACRES TOTAL NATIVE SEEDING = 3,000 SF SOD = 14,000 SF 0 SCALE 1020 NORTH D D DD J K L M N ULTIMATE DISCHARGE TO EXISTING STORM SEWER TO WALNUT CREEK Q =2.35 CFS ULTIMATE DISCHARGE TO EXISTING STORM SEWER TO WALNUT CREEK Q =0.24 CFS OP S S S S R IT NORTH NORTHNORTH 0 SCALE 510 0 SCALE 510 0 SCALE 510 Q D DD A A A A A 8"W NGAS SVC 4"SS6"SS2"W24 ST24 ST24 ST24 ST WV 24 S T 24 ST 24 ST 24 ST 24 ST 24 ST 24 ST 24 ST 24 ST 24 ST 24 ST30 ST30 ST30 STUGE-M57E (ML)UGE-M57E (ML)UGE-M57E (ML)OHE-M57EOHE-M57EOHE-M57EUGC-CTLIA01 (M/L)UGC-CTLIA01 (M/L)UGC-CTLIA01 (M/L)UGC-CTLIA01 (M/L)UGF-INS (M/L)UGF-INS (M/L)UGF-INS (M/L)UGF-INS (M/L)UGF-UPN (M/L)UGF-UPN (M/L)UGF-UPN (M/L)8"W (M/L)8"W (M/L)8"W (M/L)8"SS (M/L)8"SS (M/L)8"SS (M/L)UGE-M57E (ML)UGE-M57E (ML)UGF-WKE (M/L)UGF-WKE (M/L)6"SS (M/L)G (M/L)G (M/L)G (M/L)G (M/L)G (M/L)G (M/L)UGF-WINIA (M/L)UGF-WINIA (M/L)UGF-WINIA (M/L)8"W (M/L)SE BISHOP DRIVE(70' PUBLIC RIGHT-OF-WAY)SE UNIVERSITY AVENUE(120' PUBLIC RIGHT-OF-WAY)S89°48'03"E 172.33'S0°11'55"W 301.59'132.84'R=285.00'Δ=26°42'24"N89°48'05"W 44.24'N0°11'55"E 271.18' LOT 3 COVE AT KETTLESON PLAT 3 LOT 2 COVE AT KETTLESON PLAT 3 LOT 1 COVE AT KETTLESON PLAT 3 OUTLOT Z COVE AT KETTLESTONE PLAT 1APPROVED1060' CONTOURAPPROVED1061' CONTOURAPPROVED 1062' CONTOUR S401 S202 S402 S100 S203 S201 S213 S212 EX MH-7A S501 S400 S101 S399 S102ST-2 0 2 8"ST-501 6"ST-101 6" ST-203 8" ST-4 0 2 8"ST-401 8" EX P-7A 24"EX P-7B 30"ST-212 12"ST-211 12" ST-400 12" ST-102 6" ST-213 8" STORM STRUCTURE TABLE NAME EX MH-7A S100 S101 S102 S201 S202 S203 S212 S400 S401 S402 S501 DESCRIPTION EXISTING 48" CIRCULAR STORM SEWER MANHOLE 48" CIRCULAR STORM SEWER MANHOLE 48" CIRCULAR STORM SEWER MANHOLE 6" PIPE APRON W/ 1" ORIFICE PLATE OPENING (SW-501) SINGLE GRATE INTAKE (SW-511) RECTANGULAR AREA INTAKE (SW-511) RECTANGULAR AREA INTAKE 48" CIRCULAR STORM SEWER MANHOLE HYDRODYNAMIC SEPARATOR (SW-501) SINGLE GRATE INTAKE (SW-501) SINGLE GRATE INTAKE 6" PIPE APRON W/ 3" ORIFICE PLATE OPENING RIM/TC 1057.79 1059.58 1055.20 1054.04 1060.44 1059.88 1059.22 1056.81 1057.78 1059.67 1059.59 1057.44 INVERT INV 1051.24 (ST-501) INV 1051.14 (EX P-7A) INV 1051.04 (EX P-7B) INV 1052.38 (ST-101) INV 1052.80 (ST-101) INV 1053.20 (ST-102) INV 1053.50 (ST-102) INV 1056.83 (ST-202) INV 1056.29 (ST-212) INV 1056.39 (ST-203) INV 1056.39 (ST-202) INV 1056.93 (ST-203) INV 1056.01 (ST-212) INV 1055.91 (ST-211) INV 1056.01 (ST-213) INV 1055.31 (ST-401) INV 1055.31 (ST-211) INV 1055.21 (ST-400) INV 1056.22 (ST-402) INV 1056.12 (ST-401) INV 1057.17 (ST-402) INV 1056.90 (ST-501) STORM PIPE TABLE NAME EX P-7A EX P-7B ST-101 ST-102 ST-202 ST-203 ST-211 ST-212 ST-213 ST-400 ST-401 ST-402 ST-501 SIZE 24" Concrete Pipe 30" Concrete Pipe 6" PVC Pipe 6" PVC Pipe 8" PVC Pipe 8" PVC Pipe 12" PVC Pipe 12" PVC Pipe 8" PVC Pipe 12" PVC Pipe 8" PVC Pipe 8" PVC Pipe 6" PVC Pipe LENGTH 10 LF 13 LF 17 LF 6 LF 51 LF 60 LF 68 LF 47 LF 55 LF 9 LF 36 LF 57 LF 64 LF SLOPE 0.30% 0.31% 2.49% 4.73% 0.86% 0.90% 0.89% 0.61% 0.20% 2.39% 2.23% 1.65% 8.86% INLET INVERT 1051.14 1051.04 1052.80 1053.20 1056.39 1056.93 1055.91 1056.29 1056.01 1055.21 1056.12 1057.17 1056.90 OUTLET INVERT 1051.17 1051.00 1052.38 1053.50 1056.83 1056.39 1055.31 1056.01 1056.12 1055.00 1055.31 1056.22 1051.24 ST-501 ORIFICE OPENING DIA.= 3" ST-501 INNER PIPE DIA.= 6"1 4" STAINLESS STEEL ORIFICE PLATE. DRILL 5 8" HOLES FOR 1 2" BOLTS 3" x 3" x 3" x 1 4" ANGLE WITH 5 8" HOLE FOR 1 2" BOLT. WELD TO ORIFICE PLATE. ST-102 ORIFICE OPENING DIA.= 1" ST-102 INNER PIPE DIA.= 6"1 4" STAINLESS STEEL ORIFICE PLATE. DRILL 5 8" HOLES FOR 1 2" BOLTS 3" x 3" x 3" x 1 4" ANGLE WITH 5 8" HOLE FOR 1 2" BOLT. WELD TO ORIFICE PLATE.NOTICE: NILLES ASSOCIATES, INC. WAIVES ANYAND ALL RESPONSIBILITY AND LIABILITY FORPROBLEMS WHICH ARISE FROM FAILURE TOFOLLOW THESE PLANS, SPECIFICATIONS, ANDTHE ENGINEERING INTENT THEY CONVEY, ORFOR PROBLEMS WHICH ARISE FROM FAILURETO OBTAIN AND/OR FOLLOW THE ENGINEER'SGUIDANCE WITH RESPECT TO ANY ERRORS,OMISSIONS, INCONSISTENCIES, AMBIGUITIESOR CONFLICTS WHICH ARE ALLEGED.DATE: DRAWN BY: CHECKED BY: SHEET SIZE: SHEET TITLE: SHEET NO.: NAI NO.:PROJECT NAME:DESCRIPTION:REVISIONS:22" X 34"1250 SW STATE STREET, SUITE AANKENY, IOWA 50023-2555(515) 965-0123 phone - (515) 965-3322 faxCivil Engineering - Land SurveyingLandscape ArchitectureNilles Associates64 JPN BLH 1/12/20217.)6.)5.)4.)3.) REVISIONS PER CITY OF WAUKEE COMMENTS (2/4/2021)2.) REVISIONS PER CITY OF WAUKEE COMMENTS (1/27/2021)1.) REVISIONS PER CITY OF WAUKEE COMMENTS (1/08/2021)20216WAUKEE, IASHINE SHOP CARWASH - COVE AT KETTLESTONE PLAT 3UTILITY PLANUP-1 V:\NAI 2017\Projects 2017\20216\dwg\20216-SP.dwg PRELIMINARY - SUBMITTAL #2utility plan notes F H F GI L O M C A G A.REMOVE AND RELOCATE EXISTING FIRE HYDRANT TO PROPOSED FIRE HYDRANT LOCATION TO THE NORTH. ALL FIRE HYDRANTS SHALL HAVE 5-INCH "STORZ" FITTINGS. B.EXTEND 8" WATER SERVICE. 195 LF TOTAL. INSTALL PER SUDAS 5010. COORDINATE LOCATION OF WATER SERVICE WITH MECHANICAL PLANS PRIOR TO CONSTRUCTION. MAINTAIN PIPE DEPTH OF 5.5'. C.INSTALL 8"X8"X2" TEE AND INSTALL 12 LF OF 2" DOMESTIC WATER SERVICE WITH SHUT OFF VALVE. ADJUST VALVE BOX TO FINISHED GRADE. D. 8" 22.5 DEGREE BEND. E.8" 45.0 DEGREE BEND. F.150' HYDRANT COVERAGE RADIUS. G.CRITICAL CROSSING. MAINTAIN 18" OF SEPARATION BETWEEN UTILITIES. H.CONNECT TO EXISTING 6" SANITARY SEWER SERVICE. VERIFY LOCATION AND ELEVATION PRIOR TO CONSTRUCTION. I.INSTALL 6" SANITARY SEWER SERVICE. 143 LF TOTAL. INSTALL PER SUDAS 4010. INSTALL AT 1.04% (1 8" PER FOOT) MINIMUM SLOPE. COORDINATE LOCATION OF SANITARY SERVICE WITH MECHANICAL PLANS PRIOR TO CONSTRUCTION. J.INSTALL 4" SANITARY SEWER SERVICE TO BUILDING. 19 LF TOTAL. INSTALL PER SUDAS 4010. INSTALL AT 2% MINIMUM SLOPE. COORDINATE CONNECTION TO BUILDING WITH MECHANICAL PLANS. K.UNDERGROUND WATER RECLAMATION TANKS. REFER TO MECHANICAL PLANS FOR FURTHER DETAILS. L.ADJUST EXISTING RIM TO GRADE. A MAXIMUM OF 12 INCHES OF ADJUSTING RINGS IS ALLOWED BEFORE A NEW BARREL SECTION MUST BE ADDED. EXISTING RIM = 1059.66 PROPOSED RIM = 1059.39 M.ADJUST EXISTING RIM TO GRADE. A MAXIMUM OF 12 INCHES OF ADJUSTING RINGS IS ALLOWED BEFORE A NEW BARREL SECTION MUST BE ADDED. EXISTING RIM = 1059.50 PROPOSED RIM = 1059.81 N.750 GALLON SAND/OIL FILTER. SEE MECHANICAL PLANS FOR FURTHER DETAILS. O.CONNECT STORM SEWER TO EXISTING MANHOLE. MANHOLE TO BE CORE DRILLED AND SHALL HAVE A SOIL TIGHT CONNECTION. P.DOGHOUSE 48" CIRCULAR STORM SEWER MANHOLE OVER EXISTING 24" RCP STORM SEWER. EXISTING PIPE INVERT AT MANHOLE = 1052.28. Q.ALL SANITARY AND STORM SEWER SHALL BE CLEANED AND TELEVISED PRIOR TO PAVING. THE CITY OF WAUKEE SHALL WITNESS ALL CLEANING AND TELEVISING. COPIES OF THE REPORT AND VIDEO SHALL BE PROVIDED TO THE CITY OF WAUKEE. ALL SANITARY MANHOLES ARE TO BE VACUUM TESTED. R.NATURAL GAS SERVICE LOCATION. COORDINATE LOCATION WITH CITY OF WAUKEE PUBLIC WORKS DEPARTMENT. S.INSTALL "RAIN GUARDIAN TURRET AT CURB CUT OPENINGS TO PROVIDE PRE-TREATMENT FOR SURFACE RUNOFF. SEE SHEET DT-1 FOR ADDITIONAL DETAILS. T.ROOF DOWNSPOUT CONNECTION. REFER TO DETAIL D-1 ON THIS SHEET. U.8" CLEANOUT RIM = 1060.84 INV = 1057.43 V.INSTALL HYDRODYNAMIC SEPARATOR STRUCTURE CAPABLE OF REMOVING 80% T.S.S AT A RATE OF 0.82 CFS AND BYPASS THE 100 YEAR FLOWRATE OF 5.40 CFS. SEPARATOR TO HAVE GRATED INTAKE TOP FOR BYPASS OF LARGE STORM EVENTS. REFER TO MANUFACTURERS INSTRUCTIONS AND SPECIFICATIONS FOR DETAILS REGARDING INSTALLATION AND MAINTENANCE OF HYDRODYNAMIC SEPARATOR. REFER TO SHEET DT-1 FOR DETAIL OF STANDARD HYDRODYNAMIC SEPARATOR. 0 SCALE 1020 NORTH AB R D D E K J N P S G ST-501 ORIFICE PLATE DETAIL NO SCALEU-1 1.EXTERIOR DOWNSPOUT ASSEMBLY, DIRECT TO CENTER OF RISER 2.6" PVC RISER. EXTEND 4" ABOVE FINISHED GRADE 3.DOWNSPOUT TO EXTEND INTO RISER 4.90° BEND (6" PVC) 5.INSTALL INSERTATEE (OR APPROVED EQUAL) ON MAIN 8" TILE 6.FINISHED GRADE DOWNSPOUT CONNECTION D-1 NOT TO SCALE T T U 1 2 3 4 5 6 V ST-102 ORIFICE PLATE DETAIL NO SCALEU-2 WV UGE-M57E (ML)UGE-M57E (ML)UGE-M57E (ML)OHE-M57EOHE-M57EOHE-M57EUGC-CTLIA01 (M/L)UGC-CTLIA01 (M/L)UGC-CTLIA01 (M/L)UGC-CTLIA01 (M/L)UGF-INS (M/L)UGF-INS (M/L)UGF-INS (M/L)UGF-INS (M/L)UGF-UPN (M/L)UGF-UPN (M/L)UGF-UPN (M/L)UGF-UPN (M/L)8"W (M/L)8"W (M/L)8"W (M/L)UGE-M57E (ML)UGE-M57E (ML)UGF-WKE (M/L)UGF-WKE (M/L)G (M/L)G (M/L)G (M/L)G (M/L)G (M/L)G (M/L)UGF-WINIA (M/L)UGF-WINIA (M/L)UGF-WINIA (M/L)8"W (M/L)SE BISHOP DRIVE(70' PUBLIC RIGHT-OF-WAY)SE UNIVERSITY AVENUE(120' PUBLIC RIGHT-OF-WAY)PROPOSED 25' INGRESS/EGRESS EASEMENT S89°48'03"E 172.33'S0°11'55"W 301.59'132.84'R=285.00'Δ=26°42'24"N89°48'05"W 44.24'N0°11'55"E 271.18' 10'EXISTING 10' PUBLICUTILITY EASEMENT(BOOK 2015 PAGE 20833)EXISTING 30' PUBLIC INGRESS / EGRESS EASEMENT BOOK 2020 PAGE 22559)20'EXISTING 20' STORM SEWER EASEMENT (BOOK 2015 PAGE 20833) LOT 3 COVE AT KETTLESON PLAT 3 10'EXISTING 10' PUBLICUTILITY EASEMENT(BOOK 2019 PAGE 21475) &EXISTING 10' SANITARYSEWER EASEMENT(BOOK 2019 PAGE 20833)LOT 2 COVE AT KETTLESON PLAT 3 LOT 1 COVE AT KETTLESON PLAT 3 PROPOSED 37' INGRESS/EGRESS EASEMENT OUTLOT Z COVE AT KETTLESTONE PLAT 1PROPOSED 25' INGRESS/EGRESS EASEMENT PROPOSED 21.2' STORM WATER MANAGEMENT FACILITY MAINTENANCE COVENANT AND PERMANENT EASEMENT 12' PROPOSED ELECTRIC EASEMENT APPROVED1060' CONTOURAPPROVED1061' CONTOURAPPROVED 1062' CONTOUR1057'1058'1059'1058'1060'1060'1059'1059'1059'1060'1061'1061'1060'1057'1059'1059'1055'1056'1057'1058'1059'10 5 9 ' 1059' 1060' 1060' 1061' 1061'1060'1060'1059'1060'1 0 6 0 '1060'1058'1059'1 0 5 9 ' 1058'1058'1059'1059' 1060' 1060' 1060'1055'1060'1056'1057'1058'1059'21.2' SO RB SO BL SHSH 6 VS 6 AJ 2 NB SO SH SH SH4 NB 4 FS 3 JC KC 3 JC 3 JC 3 JC FS 4 FS SOD SOD SOD SOD SOD KC SODSO BL BL BL SOD KC KC KC SOD SHSH SH PS PS PS SOD 3 FS 4 EU RB PS SOD SOD FS 4 EU 6 VS6 AJ 5 AJ 9 VS 4 AJ 3 EU 3 JC 5.7'2. 5 '172.3'44.2'132.8'PROPOSED 27' x 150'TEMPORARY EASEMENTNOTICE: NILLES ASSOCIATES, INC. WAIVES ANYAND ALL RESPONSIBILITY AND LIABILITY FORPROBLEMS WHICH ARISE FROM FAILURE TOFOLLOW THESE PLANS, SPECIFICATIONS, ANDTHE ENGINEERING INTENT THEY CONVEY, ORFOR PROBLEMS WHICH ARISE FROM FAILURETO OBTAIN AND/OR FOLLOW THE ENGINEER'SGUIDANCE WITH RESPECT TO ANY ERRORS,OMISSIONS, INCONSISTENCIES, AMBIGUITIESOR CONFLICTS WHICH ARE ALLEGED.DATE: DRAWN BY: CHECKED BY: SHEET SIZE: SHEET TITLE: SHEET NO.: NAI NO.:PROJECT NAME:DESCRIPTION:REVISIONS:22" X 34"1250 SW STATE STREET, SUITE AANKENY, IOWA 50023-2555(515) 965-0123 phone - (515) 965-3322 faxCivil Engineering - Land SurveyingLandscape ArchitectureNilles Associates65 JPN BLH 1/12/20217.)6.)5.)4.)3.) REVISIONS PER CITY OF WAUKEE COMMENTS (2/4/2021)2.) REVISIONS PER CITY OF WAUKEE COMMENTS (1/27/2021)1.) REVISIONS PER CITY OF WAUKEE COMMENTS (1/08/2021)20216WAUKEE, IASHINE SHOP CARWASH - COVE AT KETTLESTONE PLAT 3LANDSCAPE PLANLS-1 V:\NAI 2017\Projects 2017\20216\dwg\20216-SP.dwg PRELIMINARY - SUBMITTAL #2PLANTING SOIL BACKFILL ROOT BALL - REMOVE CONTAINER OR CUT ALL GRADE AFTER SETTLING. DAMAGE LEADER BACKFILLED SOIL 24'' @ 4'' DEPTH TO COVER PLACE SHREDDED MULCH FROM TRUNK DO NOT CUT OR CHORDS & UNCOVER TOP TRUNK BASE (ROOT FLARE) SHALL NOT BE BELOW FINISHED ALL MATERIALS AS SPECIFIED CLEAR OF MULCH TRIM BRANCHES 8'' ALL MATERIALS AS SPECIFIED DO NOT CUT OR PLACE SHREDDED MULCH @ 4'' DEPTH TO COVER BACKFILLED SOIL 24'' DAMAGE LEADER FROM TRUNK TRUNK BASE (ROOT FLARE) SHALL NOT BE BELOW FINISHED GRADE AFTER SETTLING. PLANTING SOIL BACKFILL CHORDS & UNCOVER TOP CONTAINER OR CUT ALL ROOT BALL - REMOVE TO CONTAIN 1/3 PEAT MOSS 12''8''MINIMUM HOLE WIDTH CHORDS & UNCOVER TOP GRADE AFTER SETTLING. SHRUB BASE (ROOT FLARE) SHALL NOT BE BELOW FINISHED SEE PLAN FOR SPACING PLANTING SOIL BACKFILL MATERIALS OR SPACING. (CENTER TO CENTER) WITHIN LAWN AREAS. ALL MATERIALS AS SPECIFIED PLACE 3'' DEPTH SHREDDED REMOVE ANY DEAD OR DYING SEE PLAN FOR ALTERNATE MULCH AROUND ALL SHRUBS ROOT BALL - REMOVE CONTAINER OR CUT ALL BRANCHES MINIMUM HOLE WIDTH STAKING WIRE LOOP SHALL BE TWICE POSTS IN UNDISTURBED 6 FOOT STEEL FENCE THE CALIPER OF THE TRUNK SOIL ONLY RUBBER HOSE OF 2'' MOVEMENT OF TRUNK. ALLOW FOR A MINIMUM DO NOT OVERTIGHTEN ! ORIENT 3 STAKES AS SHOWN 6'' 6'' ROOT BALL PLUS 24'' ROOT BALL PLUS 24'' SEE PLAN 3 STAKES PER TREE DECIDUOUS TREE PLANTING L-1 NO SCALE CONIFEROUS TREE PLANTING L-3 NO SCALE SHRUB PLANTING L-4 NO SCALE TREE PLANTING & STAKING DETAIL L-5 NO SCALE PLANTING SOIL BACKFILL ROOT BALL - REMOVE CONTAINER OR CUT ALL GRADE AFTER SETTLING. DAMAGE LEADER BACKFILLED SOIL 24'' @ 4'' DEPTH TO COVER PLACE SHREDDED MULCH FROM TRUNK DO NOT CUT OR CHORDS & UNCOVER TOP TRUNK BASE (ROOT FLARE) SHALL NOT BE BELOW FINISHED ALL MATERIALS AS SPECIFIED STAKING WIRE LOOP SHALL BE TWICE POSTS IN UNDISTURBED 6 FOOT STEEL FENCE THE CALIPER OF THE TRUNK SOIL ONLY RUBBER HOSE OF 2'' MOVEMENT OF TRUNK. ALLOW FOR A MINIMUM DO NOT OVERTIGHTEN ! ORIENT 3 STAKES AS SHOWN 3 STAKES PER TREE TREE SLOPE PLANTING & STAKING DETAIL L-2 NO SCALE PLANTING SOIL BACKFILL ROOT BALL - REMOVE CONTAINER OR CUT ALL GRADE AFTER SETTLING. DAMAGE LEADER BACKFILLED SOIL 24'' @ 4'' DEPTH TO COVER PLACE SHREDDED MULCH FROM TRUNK DO NOT CUT OR CHORDS & UNCOVER TOP TRUNK BASE (ROOT FLARE) SHALL NOT BE BELOW FINISHED ALL MATERIALS AS SPECIFIED PROVIDE WOOD BLOCKING TO SUPPORT ROOT BALL ON DOWNHILL SIDE OF SLOPE. 0 SCALE 1020 NORTH LANDSCAPE PLAN NOTES A.PROPERTY LINE. B.PLANTING BEDS AND MAINTENANCE STRIPS AS SHOWN SHALL HAVE 1-2" DIAMETER RIVER ROCK AT 3" DEPTH PLACED OVER A WATER PERMEABLE WEED BARRIER. C.NATIVE BASIN SEEDING. TOTAL AREA = 3,000 SQ FT. SEE GENERAL NOTES FOR SEED TYPE. D.INFILTRATION TRENCH. E.EDGING SHALL BE 5" POLYETHYLENE BLACK "EDG-KING" OR EQUAL MATERIAL, INSTALLED TO MANUFACTURERS SPECIFICATIONS. GENERAL LANDSCAPING NOTES 1.ALL PLANT MATERIAL AND PLANTING SHALL BE IN ACCORDANCE WITH DIVISION 9- SECTION 9030 OF THE IOWA STATEWIDE URBAN DESIGN AND SPECIFICATIONS FOR PUBLIC IMPROVEMENTS MANUAL (SUDAS) OMITTING PARTS 2.06 AND 3.08 (TREE WRAPPING) AND SUBJECT TO THE FOLLOWING NOTES. 2.NO SUBSTITUTIONS IN SPECIES LISTED WILL BE ACCEPTED WITHOUT APPROVAL OF THE PROJECT LANDSCAPE ARCHITECT. ALL SUBSTITUTIONS SHALL BE APPROVED IN WRITING BY THE CITY OF WAUKEE DEVELOPMENT SERVICES DEPARTMENT. IF ANY UNAUTHORIZED SUBSTITUTIONS ARE MADE BY THE OWNER OR CONTRACTOR THE PROJECT LANDSCAPE ARCHITECT ASSUMES NO RESPONSIBILITY FOR THE GROWTH OR PERFORMANCE OF THE PLANT MATERIAL. 3.PLANTINGS SHALL MEET THE MINIMUM SIZES LISTED UNLESS LARGER CALIPER OR HEIGHTS ARE APPROVED BY THE OWNER AND PROJECT LANDSCAPE ARCHITECT. 4.ALL NURSERY STOCK MUST MEET THE MINIMUM STANDARDS ESTABLISHED IN THE MOST RECENT EDITION OF THE 'AMERICAN STANDARDS FOR NURSERY STOCK' PUBLISHED BY THE AMERICAN ASSOCIATION OF NURSERYMEN. 5.LANDSCAPE CONTRACTOR SHALL ENSURE PLANT MATERIAL RECEIVES ADEQUATE WATERING FOR A MINIMUM OF 30 DAYS AFTER PLANTING AND CONTINUING UNTIL SELF-SUFFICIENT. 6.PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE TIME OF INSTALLATION. SEE PLANTING DETAILS FOR ADDITIONAL PLANTING INSTRUCTION. 7.DECIDUOUS TREES IN EXCESS OF 2'' CALIPER AND CONIFEROUS TREES IN EXCESS OF 6 FEET IN HEIGHT SHALL BE STAKED OR GUYED. STAKING PROCEDURE SHALL ENSURE TRUNKS ARE PROTECTED FROM DAMAGE. STRAPS OR WIRES SHALL NOT BE OVERLY TIGHTENED TO ALLOW FOR SOME LATERAL TRUNK MOVEMENT. 8.ALL DISTURBED AREAS NOT DESIGNATED FOR PLANTING BEDS OR SPECIALTY PLANTING AREAS SHALL BE SODDED, INCLUDING AREAS IN THE PUBLIC RIGHT OF WAY. TOTAL SOD QUANTITY = 18,437 SF. 9.SODDING SHALL BE IN ACCORDANCE WITH DIVISION 9 - SECTION 9020 OF THE IOWA STATEWIDE URBAN DESIGN AND SPECIFICATIONS FOR PUBLIC IMPROVEMENTS MANUAL (SUDAS). 10.NATIVE BASIN SEED MIXTURE SHALL BE DETENTION BASIN SEED MIX AS PROVIDED BY PRAIRIE MOON NURSERY. WWW.PRAIRIEMOON.COM, 32115 PRAIRIE LANE, WINONA, MN 55987, OR APPROVED EQUAL. INSTALL AS PER SUDAS SPECIFICATIONS 9010 SEEDING. PROVIDE NURSE CROP OF OATS. BFM HYDROMULCH SHALL BE APPLIED OVER SEEDING PER SUDAS SECTION 9010. 11.ALL PLANTING BEDS DESIGNATED FOR MULCH INCLUDING AREAS AROUND TREES & SHRUBS) SHALL BE 3'' DEPTH SHREDDED HARDWOOD - 4' DIAMETER (TREES) AND 2' DIAMETER (SHRUBS). A PRE-EMERGENT SUCH AS "PREEN" OR APPROVED EQUAL HERBICIDE SHALL BE APPLIED AT THE MANUFACTURER'S RECOMMENDED RATE IMMEDIATELY AFTER MULCHING. Common / Scientific name TREES & SHRUBS Key Root,CommentMinimum Size No. SH Gleditsia triacanthos f. inermis 'Skycole' Skyline Honey Locust 88' Height B&B or Container KC Gymnocladus dioica Kentucky Coffee Tree 'Espresso'58' Height B&B or Container PLANTING SCHEDULE BL Picea pungens Blue Spruce 46' Height B & B or SPADE RB Betula nigra 'Cully' HERITAGE Heritage River Birch 2 8' Height Multi-stem B&B or Container JC Juniperus chinensis 'pfitzeriana compacta' Compact Fitzer Juniper Container1518-24" Height LANDSCAPING CALCULATIONS (LANDSCAPE CALCULATIONS BASED UPON CITY OF WAUKEE ZONING CODE REQUIREMENTS AND THE KETTLESTONE DESIGN GUIDELINES PUD) OPEN SPACE REQUIRED: 15% 48,002 SF X 15% = 7,200 SF REQUIRED (21,356 SF PROVIDED) OPEN SPACE PLANT UNITS REQUIREMENT 1.0 OVERSTORY TREES, 0.5 UNDERSTORY TREES, AND TWO (2) SHRUBS FOR EVERY 1,000 SQ. FT. OF REQUIRED OPEN SPACE. 7,200 / 1,000 = 7.200 PLANT UNITS (PU'S) 1 OVERSTORY TREE X 7.200 PU'S = 7.2 REQUIRED (10 OVERSTORY TREES PROVIDED) 0.5 UNDERSTORY TREE X 7.200 PU'S = 3.6 REQUIRED (4 UNDERSTORY TREES PROVIDED) 2 SHRUBS X 7.200 PU'S = 14.4 REQUIRED (87 SHRUBS PROVIDED) MINIMUM OF 50% OF TOTAL REQUIRED TREES SHALL BE OVERSTORY. 12 TREES REQUIRED X 50% = 6 OVERSTORY TREES REQ'D (10 PROVIDED) MINIMUM OF 25% OF TOTAL REQUIRED TREES SHALL BE EVERGREEN. 12 TREES REQUIRED X 25% = 3 EVERGREEN TREES REQ'D (4 PROVIDED) FOUNDATION PLANTINGS: FOUNDATION PLANTINGS ARE REQUIRED AT THE BASE OF ALL BUILDINGS. OFF-STREET PARKING AREAS: PARKING LOT ISLANDS SHALL HAVE A MINIMUM OF 1 OVERSTORY TREE (3 TREES PROVIDED) BUFFER REQUIREMENT: THERE ARE NO BUFFER REQUIREMENTS. STREET TREE REQUIREMENT: SE UNIVERSITY AVE. : 1 OVERSTORY TREE PER 40 LF OF FRONTAGE 172.3 LF / 40 = 4.3 STREET TREES REQUIRED (4 STREET TREES PROVIDED) SE BISHOP DR. : 1 OVERSTORY TREE PER 40 LF OF FRONTAGE 177 LF / 40 = 4.3 STREET TREES REQUIRED (5 STREET TREES PROVIDED) MINIMUM HEIGHT REQUIREMENTS: DECIDUOUS OVERSTORY TREES SHALL BE A MINIMUM OF 8' IN HEIGHT. EVERGREEN TREES SHALL BE A MINIMUM OF 6' IN HEIGHT. DECIDUOUS ORNAMENTAL TREES SHALL BE A MINIMUM OF 6' IN HEIGHT. STREET TREES SHALL BE A MINIMUM OF 12' IN HEIGHT. PS Malus hybrida 'Pink Spires' Pink Spires Crabapple 46' Height B&B or Container SO Quercus bicolor Swamp White Oak 48' Height B&B or Container A A A A B B B B B C B D VS Clethra alnifolia 'Caleb' Vanilla Spice Summersweet Container2124" Height AJ Physocarpus opulifolius 'Jefam' Amber Jubilee Ninebark Container2124" Height NB Myrica pensylvanica Northern Bayberry Container624" Height FS Rhus aromatica 'Gro-low' Gro-low Fragrant Sumac Container1312-18" Height EU Euonymus fortune ‘Gold Splash’ Gold Splash Euonymus Container1112-18" Height E E DETENTION BASIN FLOOR. REFER TO GRADING PLAN FOR SLOPES AND ELEVATIONS. UNDISTURBED SOIL BASIN OUTLET. REFER TO UTILITY PLAN FOR FURTHER DETAILS INFILTRATION TRENCH AGGREGATE BACKFILL. REFER TO DETAIL D-2 FOR FURTHER INFORMATION. ALIGN TOP OF PEA GRAVEL FILTRATION LAYER WITH PROPOSED ELEVATION OF DETENTION BASIN FLOOR ALIGN TOP OF PEA GRAVEL FILTRATION LAYER WITH PROPOSED ELEVATION OF DETENTION BASIN FLOOR OBSERVATION WELL CONSTRUCTED OF 6" PVC PIPE W/ LOCKABLE CAP. REFER TO ISWMM CHAPTER 5 SECTION 2 FOR FURTHER SPECIFICATIONS. TOP OF INFILTRATION TRENCH EQUAL TO BOTTOM ELEVATION OF DETENTION BASIN. REFER TO GRADING PLAN FOR BASIN DETAILS. BASIN SIDE SLOPES 4:1 TYPICAL. REFER TO GRADING PLAN FOR FURTHER DETAILS. 2" PEA GRAVEL FILTER LAYER. PROTECTIVE LAYER OF FILTER FABRIC LOCATED BETWEEN PEA GRAVEL LAYER AND TRENCH STONE. TRENCH 6 FEET DEEP FILLED WITH 1.5-2.5 INCH DIAMETER CLEAN STONE. 6" DEEP SAND FILTER RUNOFF EXFILTRATES THROUGH UNDISTURBED SUBSOILS WITH A MINIMUM RATE OF 0.5 INCHES PER HOUR 0.16'6.00'0.5'5.50' UNDISTURBED SOIL PROTECTIVE LAYER OF FILTER FABRIC LOCATED BETWEEN AGGREGATE AND UNDISTURBED EARTH TO PREVENT SOIL CONTAMINATION. OBSERVATION WELL CONSTRUCTED OF 6" PVC PIPE W/ LOCKABLE CAP. REFER TO ISWMM CHAPTER 5 SECTION 2 FOR FURTHER SPECIFICATIONS.NOTICE: NILLES ASSOCIATES, INC. WAIVES ANYAND ALL RESPONSIBILITY AND LIABILITY FORPROBLEMS WHICH ARISE FROM FAILURE TOFOLLOW THESE PLANS, SPECIFICATIONS, ANDTHE ENGINEERING INTENT THEY CONVEY, ORFOR PROBLEMS WHICH ARISE FROM FAILURETO OBTAIN AND/OR FOLLOW THE ENGINEER'SGUIDANCE WITH RESPECT TO ANY ERRORS,OMISSIONS, INCONSISTENCIES, AMBIGUITIESOR CONFLICTS WHICH ARE ALLEGED.DATE: DRAWN BY: CHECKED BY: SHEET SIZE: SHEET TITLE: SHEET NO.: NAI NO.:PROJECT NAME:DESCRIPTION:REVISIONS:22" X 34"1250 SW STATE STREET, SUITE AANKENY, IOWA 50023-2555(515) 965-0123 phone - (515) 965-3322 faxCivil Engineering - Land SurveyingLandscape ArchitectureNilles Associates66 JPN BLH 1/12/20217.)6.)5.)4.)3.) REVISIONS PER CITY OF WAUKEE COMMENTS (2/4/2021)2.) REVISIONS PER CITY OF WAUKEE COMMENTS (1/27/2021)1.) REVISIONS PER CITY OF WAUKEE COMMENTS (1/08/2021)20216WAUKEE, IASHINE SHOP CARWASH - COVE AT KETTLESTONE PLAT 3DETAIL SHEETDT-1 V:\NAI 2017\Projects 2017\20216\dwg\20216-SP.dwg PRELIMINARY - SUBMITTAL #2INFILTRATION TRENCH PROFILE VIEW NO SCALED-1 INFILTRATION TRENCH ELEVATION DETAIL NO SCALED-2 RAIN GUARDIAN TURRET CROSS-SECTION VIEW U.S. PATENT 8,501,016 INLET CURB GUTTERLINE RAIN GUARDIAN TURRET INLET HIGH VOLUME OVERFLOW TOP FIBERGLASS GRATE RAIN GUARDIAN TURRET (CONCRETE BASE INCLUDED) GUTTERLINE PRIMARY OUTLETREMOVABLE FILTER WALL BASIN BOTTOM CLASS 5 AGGREGATE SUBSOILS RAIN GUARDIAN - PLAN R-2 NOT TO SCALE 5"5"5.5"6"SITE SPECIFIC1' 3.5"1' 1.75"1'4"6"INSURMOUNTABLE CURB FACE BACK OF CURB RAIN GUARDIAN TURRET (CONCRETE BASE INCLUDED) POSITION RAIN GUARDIAN TURRET SO PRIMARY OUTLET ALIGNS WITH TOE OF BASIN SIDE SLOPE TO AVOID SOIL INTERFERENCE WITH FILTER INSURMOUNTABLE CURB FACE CONCRETE INLET CURB-CUT (8.25' STANDARD)1.95' STANDARD4' 2"4' 1"3' 10"3' 8"RAIN GAURDIAN - PROFILE R-1 NOT TO SCALE INSTALLATION NOTES A.ANY SUB-BASE, BACKFILL DEPTH, AND/OR ANTI-FLOTATION PROVISIONS ARE SITE-SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE SPECIFIED BY ENGINEER OF RECORD. B.CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE CDS MANHOLE STRUCTURE. C.CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL STRUCTURE SECTIONS AND ASSEMBLE STRUCTURE. D.CONTRACTOR TO PROVIDE, INSTALL, AND GROUT INLET AND OUTLET PIPE(S). MATCH PIPE INVERTS WITH ELEVATIONS SHOWN. ALL PIPE CENTERLINES TO MATCH PIPE OPENING CENTERLINES. E.CONTRACTOR TO TAKE APPROPRIATE MEASURES TO ASSURE UNIT IS WATER TIGHT, HOLDING WATER TO FLOWLINE INVERT MINIMUM. IT IS SUGGESTED THAT ALL JOINTS BELOW PIPE INVERTS ARE GROUTED. HYDRODYNAMIC SEPARATOR DETAIL S-1 NOT TO SCALE PLAN VIEW N.T.S. FIBERGLASS SEPARATION CYLINDER AND INLET CENTER OF CDS STRUCTURE, SCREEN AND SUMP OPENING PVC HYDRAULIC SHEAR PLATE ELEVATION N.T.S. FIBERGLASS SEPARATION CYLINDER AND INLET SOLIDS STORAGE SUMP SEPARATION SCREEN OUTLET PIPE PVC HYDRAULIC SHEAR PLATE OIL BAFFLE SKIRT CONTRACTOR TO GROUT TO FINISHED GRADE GRADE RINGS/RISERS 48" [1219] I.D. MANHOLE STRUCTURE TOP SLAB ACCESS (SEE FRAME AND COVER DETAIL)(4'-6")VARIESINFILTRATION TRENCH MAINTENANCE SCHEDULE 1. ARCHITECTURAL 100' -0" = SURVEY 1061.00'2. DO NOT SCALE DRAWINGS. DRAWN DIMENSIONS SHALL TAKE PRECEDENCE. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES IMMEDIATELY.3. REFER TO DOOR AND WINDOW SCHEDULES FOR MORE INFORMATION.4. SEE CIVIL DRAWINGS FOR DRAINAGE REQUIREMENTS.5. GRADE SOIL AWAY FROM BUILDING TO DRAIN. SEE CIVIL AND LANDSCAPE DRAWINGS FOR MORE INFORMATION.6. ALL EXTERIOR FINISHES, MATERIALS, AND SYSTEMS ARE TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS.ATTENTION:CONTRACTOR TO PROVIDE AN EXTERIOR FINISH MOCK-UP WALL, 4' WIDE BY 6' HIGH MINIMUM, FOR OWNER AND/OR ARCHITECT APPROVAL PRIOR TO ANY EXTERIOR FINISH CONSTRUCTION. MOCK-UP WALL TO HAVE ALL EXTERIOR COMPONENTS REPRESENTED INCLUDING GROUT, SEALANTS, FLASHING, ETC.ELEVATION GENERAL NOTESLEVEL 1100'-0"ST-1SF-1MTL-2MTL-4MTL-3ST-1MTL-5STU-1CS-2STUCCO REVEALMTL-5MTL-5ST-2SF-1MTL-1ST-1MTL-3MTL-2ST-2MTL-6MTL-6E.J.E.J.E.J.E.J.PANTED METAL CANOPY-COLOR TO MATCH MTL-2 COLORE.J.CS-1CS-2CS-2CS-1LEVEL 1100'-0"ST-1MTL-5MTL-2MTL-3MTL-4SF-1ST-1CS-1MTL-5STU-1STUCCO REVEALMTL-5STU-1ST-1MTL-3ST-2CS-1MTL-3SF-1CS-1PREFINISHED ALUMINUM LOUVRE E.J.E.J.10"3'-0"4'-6"E.J.CS-2CS-2CS-2LEVEL 1100'-0"ST-1MTL-5MTL-3ST-1ST-2SF-1MTL-2MTL-1FULL VISION TRANSPARENT OHSDCS-2LEVEL 1100'-0"ST-1MTL-3MTL-5MTL-2MTL-4STU-1ST-1MTL-52'-10"STUCCO REVEALST-2CS-2FULL VIEW TRANSLUCENT OVERHEAD DOOR -PANTED METAL CANOPY-COLOR TO MATCH MTL-2 COLORCS-2OHSDOVERHEAD COILING DOOROHCD4'-6"1'-3"CS-21'-7 1/4"1'-8"1'-7 1/4"4'-2"6'-0"ST-2FRONTNOTE: PREPARE STEEL FOR PRIMERAND PAINT PER SPECIFICATIONSMTL-57'-0"FRONTPROVIDE HEAVY DUTYGALVANIZED STEELLATCH AND CANE BOLTS.6'-0"METAL GATE, 2x2 TUBE STEEL WITH 1x2ANGLE BRACE FRAME WITH PREFINISHEDMETAL M-PANEL INSET. USE 1x1 ANGLES ATPERIMETER FOR PANEL SUPPORT.6" STEEL CHANNELEACH SIDE,SEE STRUCTURAL,WELD HEAVY DUTYGATE PIVOTSTOP/BOTTOM.ST-2SIDE7'-0"MTL-5ST-2SIDENOTE: PREPARE STEEL FOR PRIMERAND PAINT PER SPECIFICATIONS6'-0"MTL-5METAL FLASHING OR STUCCO END TERMINATION2"3-COAT CEMENT PLASTER 7/8" STUCCO WITH METAL LATH OVER CMU.STONE -SEE ELEVATION FOR TYPESMANUFACTURER ADHERE STONE SILL (CS-2)7 5/8"1/4"2 1/2"3/8"1605 N. ANKENY BLVD #130ANKENY, IOWA 50023PHONE: (515) 965-5336FAX: (515) 965-5335info@imprintarchitects.comPROJECT:DATE:DRAWN BY:CHK'D BY:REVISED:PERMIT SETC:\Users\srashid\Documents\20-135-Shine Car Wash_Arch_Central Model_R20_IA-srashid.rvt2/22/2021 11:29:24 AMA20020-135COVE AT KETTLSTONE PLAT3 ,WAUKEE, IAFOR : SUMMIT EQUITYSHINE SHOP CARWASHEXTERIORELEVATIONS01/18/21SR--1/8" = 1'-0"5EAST ELEVATION1/8" = 1'-0"3WEST ELEVATION1/8" = 1'-0"4SOUTH ELEVATION1/8" = 1'-0"2NORTH ELEVATION1/4" = 1'-0"6VACUUM ENCLOSURE ELEVATION1/4" = 1'-0"7DUMPSTER ENCLOSURE ELEVATION-1EXTERIOR FINISH LEGENDNAME KEY PRODUCT DESCRIPTIONCAST STONE CS-1 EDWARD CAST STONE - COLOR TBDCAST STONE CS-2 MANUFACTURER ADHERED STONE - COLOR TBDMETAL COMPONENTS MTL-1 CLEAR ANODIZED ALUMINUM BRAKE METALMTL-2 PAC CLAD BLUEMTL-3 PAC CLAD BONE WHITEMTL-4 PREFINISHED CLEAR ANODIZED ALUMINUMMTL-5 PREFINISHED COPINGS AND TRIMS TO MATCH ADJACENTMTL-6 PREFINISHED GUTTERS AND DOWNSPOUTS TO MATCH ADJACENTDOOR OHCD OVERHEAD COILING DOOROHSD OVERHED FULL VISION TRANSPARENT DOORSTONE ST-1 ELDORADO STONE - FOGGY MEADOW FINISHSTONE ST-2 ELDORADO STONE - SILENT GREY FINISHSTOREFRONT SYSTEM SF-1 CLEAR ANODIZED ALUMINUM, SEE WINDOW TYPES FOR MORE INFOSTUCCO STU-1 3 COAT STUCCO 7/8" THICK, SANDBLAST FINISH, PAINTED SW7066GREY MATTERS4' WIDE METAL GATE, 2x2 TUBE STEEL WITH 1x2ANGLE BRACE FRAME WITH PREFINISHEDMETAL M-PANEL INSET. USE 2X3 ANGLES CHANNEL FOR JAMB BOLT TO THE CMU .HARDWARE : LOCK : STANDARD EXTERIOR LOCK ASSEMBLY FOR METAL DOORHINGES -3 MANUFACTURER STANDARD PIVOTS1 1/2" = 1'-0"8TYPICAL STONE TO STONE/EIFS TRANSITION