Loading...
HomeMy WebLinkAbout2021-04-05-J01S SE Ashworth Rd Corridor_Overhead to Underground ProposalCITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: April 5, 2021 AGENDA ITEM:Consideration of approval of a resolution approving Overhead to Underground Proposal from MidAmerican Energy Company [SE Ashworth Rd, WMIS 2814509] FORMAT:Resolution SYNOPSIS INCLUDING PRO & CON: MidAmerican Energy proposes to relocate their overhead electrical facilities to underground facilities along SE Ashworth Road to accommodate the SE Ashworth Rd Corridor Improvements project currently underway. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: MidAmerican Energy’s Relocation expense is estimated to be $436,819.35. Staff have indicated to MidAmerican Energy of the City’s intent to utilize the local government compliance clause to compel MidAmerican Energy to recover the actual costs for this relocation effort from their customers within the corporate boundaries of Waukee. MidAmerican Energy will assign a monthly per kilowatt-hour (kWh) basis fee applied to their customer’s electric utility bill for a one year duration. The estimated fee is $0.00252/kWh. For the average residential customer, the monthly fee is estimated to be $2.12/month and for the average commercial customer, this fee is estimated to be $14.61/month. COMMISSION/BOARD/COMMITTEE COMMENT: STAFF REVIEW AND COMMENT: RECOMMENDATION: Approve the resolution. ATTACHMENTS: I. Proposed Resolution II. MidAmerican Proposal and Design PREPARED BY: Beth Richardson REVIEWED BY: Rudy Koester RK PUBLIC NOTICE INFORMATION – NAME OF PUBLICATION: DATE OF PUBLICATION: AGENDA ITEM: J1S THE CITY OF WAUKEE, IOWA RESOLUTION 2021- APPROVING MIDAMERICAN ENERGY COMPANY PROPOSAL FOR OVERHEAD TO UNDERGROUND PROPOSAL [SE ASHWORTH ROAD CORRIDOR IMPROVEMENTS, WMIS 2814509] IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee is a duly organized municipality within Dallas County; AND, WHEREAS, the City of Waukee requested a proposal from MidAmerican Energy Company to relocate overhead electric system along SE Ashworth Road Corridor; AND, WHEREAS the removal and/or relocation of overhead electric facilities would improve safety, image and economic development. NOW THEREFORE BE IT RESOLVED by the City of Waukee City Council that the City of Waukee hereby approves the MidAmerican Energy Company Overhead to Underground Proposal [SE Ashworth Road Corridor, WMIS 2814509]. Passed by the City Council of the City of Waukee, Iowa, and approved the 5th day of April, 2021. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Anna Bergman R. Charles Bottenberg Chris Crone Larry R. Lyon Ben Sinclair 1 | P a g e W M I S | 2814509 2/16/2021 City of Waukee 805 University Ave. Waukee, IA 50263 rkoester@waukee.org Dear Mr. Koester: Re: Relocation of overhead electric facilities to underground along SE Ashworth Rd. in Waukee, IA. WMIS 2814509 In response to your request, MidAmerican Energy Company has reviewed the above project and your request for relocation of our overhead electric system. To facilitate your request for conversion of these overhead distribution facilities to an underground system, we have prepared a design proposal for an estimated total of $436,819.35 to the city that would remove the overhead facilities and install them underground. This cost does include the adverse conditions charges. Since the estimated cost of construction is over $100,000, the City is required by tariff to pay actual costs upon completion of the work, which could result in an additional charge or a refund to the City. This proposal provides the terms and conditions for relocation of our electric distribution facilities only. If adjustments to streetlight facilities are required, the terms and conditions for those projects will be included on a separate proposal. This proposal is valid for 90 days and assumes MidAmerican will be allowed to commence construction within 12 months of the proposal date. MidAmerican proposes to: 1. Remove overhead distribution facilities as shown on the attached drawings. 2. Furnish and install underground cable, switchgears and other pad mounted equipment as shown. 3. Provide a field representative to review plans with the contractor hired to install conduit system. 2 | P a g e W M I S | 2814509 2/11/2021 Under the terms and conditions of this proposal, the City Agrees to: 1. Notify, facilitate and compel all other utilities located on MidAmerican Energy company’s poles to relocate to underground. 2. City shall grade the underground primary cable route for direct burial cable to within four inches of final grade and clear the cable route of construction materials, obstructions, and ECT. This grading and clearing shall be done as required to facilitate MidAmerican’s schedule for cable installation with no unreasonable delays. In the event the City is unable to provide grade preparation according to these specifications or cannot clear any known obstructions in the proposed facility route, the City shall reimburse MidAmerican for all incremental costs incurred by MidAmerican or its contractors resulting therefrom. 3. The City shall furnish, stake and maintain easements for the duration of the project for all MidAmerican Energy pad mounted electrical equipment as shown on drawings 4. The City shall perform all site restoration necessitated by installation of underground facilities. 5. The City shall stake elevations and Right of Way along the underground cable path and maintain staking for the duration of project. 6. This proposal assumes that MidAmerican Energy will not be required to perform any temporary relocations of the overhead system, and can leave it in place and operable until the completion of the installation of the new underground facilities. Any incremental costs incurred by MidAmerican for such temporary modifications shall be paid by the City. 7. The City shall pay all costs incurred by MidAmerican Energy resulting from design changes or field changes made by the City that deviate from the plans provided by the City for preparation of this proposal. 8. If MidAmerican Energy is required to start construction during the winter season, this work may be subject to a winter construction charge which is included in this estimate. 3 | P a g e W M I S | 2814509 2/16/2021 If this proposal is satisfactory, please sign and return one copy of this letter to me. Payment may be withheld until completion of the project and will be billed to actuals. If you have any questions or concerns, please call me at (515) 252-6742. Sincerely, Scot Enger Customer Project Coordinator Accepted By: _________________________Date: _____________________ Requested Start Date: ____________________________________________ Requested Completion Date: _______________________________________ SEC CAP SEC CAP VERMILLION CTCHRISTIE LNGRAND PRAIRIE PKWY3207 3240 3219 3224 3232 3227 3241 3223 3233 3256 3250 3242 11502870287528802885 3257 3261 3265 3267 3271 3273 3277 3251 3255 P B B B B B B B B B 2 ACSR (2 ACSR)4 ACSR (4 ACSR)4 ACSR (4 ACSR)2 ACSR (2 ACSR)2 ACSR (2 ACSR)1/0 AL JACKETED1/0 AL JACKETED750 AL PARA 750 AL PARA 750 AL PARA 750 AL PARA 750 AL PARA 1/0 AL JACKETED4/0 AL PARA4/0 AL PARA 1/0 AL JACKETED1/0 AL JACKETED 1/0 AL JACKETED 1/0 AL JACKETED 1/0 AL JACKETED 1/0 AL JACKETED 2 ACSR (2 ACSR )2 ACSR 6/1 (2 ACSR 6/1)2 AC S R 6 / 1 ( 2 A C SR 6 / 1 )1/0 ACSR 6/1 (1/0 ACSR 6/1)2 ACSR 6/1 (2 ACSR 6/1)2 ACSR 6/1 (2 ACSR 6/1)COMMON NEUTRAL750 AL PARA 336 ACSR 18/1 (4/0 ACSR 6/1)4/0 AL PARAEL203EL203EL203EL203EL203EL203 EL203 EL203EL203EL203 EL203 EL203 EL203 EL203 EL203EL203EL203 EL203EL203 EL203 EL203 EL203 EL203 EL203EL203EL203EL203EL203 EL203 EL203UGUG UGCOCUG COC UG COC UG COC UG CO C UG COC UGUGCOCUGCOCU G C O C 13 OF 4 / 0 U G A L T R I P L E X 69 OF 1 / 0 U G A L T R I P L E X 7 OF 1/0 UG AL TRIPLEX UG UG COC 12 0 / 2 0 8 SIREN CTV                                                    0005090965 0016877685 00185309990018531002 0017685381 SG-JC553 0019433698 PP0098 0019448968 SG-JC556 0019448975 SG-JC554 0019449078 0019449109 PP0099 0019449211 0019449219 0019450278 0019450302 0019450311 0019450321 3247 Ashworth P.E.0018624037                        65T 65T 65T 65T 65T 65T 65T 65T 200E 200E 200E 200E 200E 200E 200E 30E 30E 200E200E 65T 65T 65T 65T 140T 140T K429 V025A V025B V407 V086 V087 X620 JC557 SG-JC553-02 SG-JC553-06 SG-JC553-05 SG-JC553-04 SG-JC556-06 SG-JC556-04 SG-JC556-05 SG-JC556-02 SG-JC554-02 SG-JC554-05SG-JC554-06 X617A U150 X733 X619 X028 PH37          MD04 JC552 JC555 SG-JC553-01 SG-JC553-03 SG-JC556-01 SG-JC556-03 SG-JC554-01 SG-JC554-03 SG-JC554-04 MD01 MD02X626   1 - 6.00 - CONTINUOUS POLYETHELYNE1 - 4.00 - CONTINUOUS POLYETHELYNE1 - 4.00 - CONTINUOUS POLYETHELYNE1 - 2.00 - CONTINUOUS PO L Y E T H E L Y N E 1 - 2.00 - CONTINUOUS POL Y E T H E L Y N E 1 - 2.00 - CONTINUOUS POLYET H E L Y N E 1 - 2.00 - CONTINUOUS POLY E T H E L Y N E 1 - 2.00 - CONTINUOUS P O L Y E T H E L Y N E 1 - 4.00 - CONTINUOUS POLYETHELYNE 1 - 6.00 - CONTINUOUS P O L Y E T H E L Y N E 1 - 4.00 - CONTINUOUS POLYETHELYNE1 - 6.00 - CONTINUOUS P O L Y E T H E L Y N E 1 - 6.00 - CONTINUOUS POLYETHELYNE 1 - 6.00 - CONTINUOUS P O L Y E T H E L Y N E 1 - 6.00 - CONTINUOUS POLYETHE L Y N E 1 - 6.00 - CONTINUOUS POLYETHELYNE                   600 900 900 600 600 600 600 600 600 600 600 600 600 25 25 50 B PHS 25 KVA120/240 B PHS 25 KVA120/240 B PHS 25 KVA 120/240 B PHS 25 KVA120/240 B PHS 25 KVA 120/240 B PHS 25 KVA120/240 25 25 B PHS 25KVA 120/240 300 CONDUITS & TRACER WIRESTUBBED AT THIS LOCATION LOCATOR NEEDS TO LOCATETHESE CONDUITS CONDUITS & TRACER WIRESTUBBED AT THIS LOCATION LOCATOR NEEDS TO LOCATETHESE CONDUITS CONDUITS & TRACER WIRESTUBBED AT THIS LOCATION LOCATOR NEEDS TO LOCATETHESE CONDUITS <<<<<<<<<<420693 CS19673 CS19678                                 SEC CAP {V AVE}UTE AVEASHWORTH RD HUNTER HOLLOW RDSE L A GRANT PKWY3116831 6 52 31370 32 0 5 6 3 20 4731329 3 16 7 8 31635 3151 318231943214 3182 31908 3176 31541 32027295 3204 540 550 570 580 317031802655PP PB B B BB B B A2 ACSR 6/1 (2 ACSR 6/1)1/0 AL JACKETED1 /0 AL J ACKETED1/0 ACSR 6/1 (1/0 ACSR 6/1)1/0 AL JACKETED336 ACSR 18/1 (4/0 ACS R 6 / 1 ) 750 AL PARA 4 /0 ACSR 6/ 1 ( 4 / 0 ACSR 6/ 1 ) 336 ACSR 18/1 (4/0 ACS R 6 / 1 ) 336 ACSR 18/1 (4/0 ACS R 6 / 1 ) 750 AL PARA 1/0 AL JACKETED1/0 AL JACK E T E D 1/0 AL JACKE L 2 0 3 EL203 EL203EL203EL203DEB213 DEB213 EL203EL203EL203 EL203 EL203 EL203DEB21 3EL2 0 3EL203 EL203 EL203EJ201 EL203 EL203UG COC UG COC U G C O C U G C O C UG COC UG COC COC UG COC UG COC UG COC UG COC UG CO C UG COC COCU G C O C COCU G C O C UG C O CUGCOCUGCOCUG COC UGCOCUGCOCUG COC UGCOCUGCOCUG COC UG COC UG COC UG COC 111 OF 3 5 0 U G A L T R I P L E X 73 OF 350 U G AL T RIPLE X UGCOC480/277480/277 480/277PHONE T R L TTRLT                                                                   0016209228 0017592945 00191108100019145097 0019145138 0019145411 0019240852 0005091051 0005091122 0005091406 0005099191 0010110195 0010154838 0010460536 0010697744 0010938356 0010971647 0011230095 0013003581 0013154700 0015693688 0015927654 0016312581 0016409507 0016464977 0016759883 0016815649 0018694652 0018694663 0018694674 0019054180 0019054304 0019055317 0019431847                     65T 65T 25T 100T 40T 30T 100T 100T 100T 100T 100T 100T 100T 100T 100T 40T 100T C247 V407 SD91 K0843 X621B B1003-A B1003 WS86 X622 WS88 M215 Z022 X623 Z046 WS93 X342 Z696      WS89 WS90 WS91 WS92 OPEN MR31 FY09   1 - 2" - PVC2 - 4.00 - PVC 1 - 6.00 - CON T I N U O U S P O L Y E T H E L Y N E 1 - 2.00 - CO N T I N U O U S P O L Y E T H E L Y N E         600 600 600 600 600 600 50 50 5025 25 2525 25 50 B PHS 50 KVA 120/240 B PHS 50 KVA120/240 25 50 300 1000 25 25 25 25 25 25 25 <<<<< <<<<<<<< 207640 282868 247030 247031 247032 247033 247034 CS19589                      SEC CAP {HWY F64}98 STASHWORTH RD WACO PL98 ST98 STUNKNOWN UNKNOWN UNKNOWN 3273 3277 3281 3285 3289 3293 3307 3320 3321 3319 31813169B B B B 2 ACSR (2 ACSR)336 ACSR 18/1 (4/0 ACSR 6 / 1 )1/0 ACSR 6/1 (1/0 ACSR 6/1)2 ACSR (2 ACSR)1/0 AL JACK336 ACSR 18/1 (4/0 A C S R 6 / 1 )6 CU (6 CU SOL HD)2 ACSR 6/1 (2 A C S R 6 / 1 )750 AL PARA6 CU (6 CU SOL HD)750 AL PARA336 ACSR 18/1 (4/0 ACSR 6/1)1/0 AL JACKETED 2 ACSR (2 ACSR )EL203EL203EL203 EL203EL203EL203EL203EL203 EL203UG CO C UG COCUG                                0005099250 0017802530 0016746183           65T 40T 65T 65T 65T 65T 65T 100TOPEN 65T N020 X620 X611 X614 X632A X632B R9924 R9923 JC557 MD03   1 - 2.00 - CONTINUOUS P O L Y E T H E L Y N E  900 25 25 25 25 50<<<<<<<<273925 CS19568       RF ENERGY HAZARDCONTACT OWNER IN ADVANCETO DE-ENERGIZE ANTENNABEFORE APPROACHING POLE TOPAT&T - 800-638-2822LOCATION ID: IADMW_003 DOES NOT PHASE 98 ST98 STCHALK ST WESTOWN PKWY UNKNOWN UNKNOWNUNKNOWN UNKNOW N UN K N O W N UNKNO W NUNKNOWN WESTO W N P K W Y95 ST93 STWILSON ST WILSON ST WILS O N S T 94 ST97 STDAVIS DR 31699675 9655 9635 9585 9565 9545 9525 9495 9465 9658 9638 9618 9586 9566 9546 9526 9506 9494 9474 945413381332132697 0 4 9678 9434 9414 94041330 1313135313 1 5 1323 133113391347133013381346136313551354135013339187 9193917 2 917 6 918 0 918 23118965097979 7 9 4 9764 9734 9704 9696 9680 9664 9648 9632 9616 9590 9570 9550 14559450 9470 9522 9542956295829624964496649684 9465 9485 9507 9547956795879609962996499669968997259775 13501344930 3 9323 9343 9363 9383 9405 9425 9445PB C BA 1/0 AL PARA 1/0 AL JACKETED1/0 AL JACKETED 1/0 AL JA C K E T E D 1/0 AL JACKETED 750 AL PARA750 AL PARA750 AL PARA1/0 AL JACKETED1/0 AL JACKETED750 AL PARA 2 trenches; lines are paral l e l 3 ' a p a r t 2 trenches; lines are parra l l e l 3 ' a p a r t EL203 EL203 EL203EL203 EL203 EL203EL203 EL203EL203EL203EL203EL203UGCOCUG UGCOCCOC COC480/277WIFI WIFI                                                 RF ENERGY HAZARDCONTACT OWNER IN ADVANCE TO DE-ENERGIZE ANTENNABEFORE APPROACHING POLE TOP US CELLULAR - 1-800-510-6091LOCATION ID: WDM GOLF 8                                                 0017160988 00124052910012405293 0012405311 0012405316 0012405369 0012405371 0012542028 0012542031 0012542110 0012883051 0012883066 0013095629 0014985047 0016732254 0016733318 0016746183 0017153542 0017153575 0017153579 0017153598 0017154182 0011442319 0012022254 0012022329 0012405279 0012405283 0012405307 0012405310 0012405313 0012405360 0012405364 0012405365 0012405366 0012405368 0012405373 0012405376 0012542015 0012542021 0012542112 0012542114 0012542115 0012542117 0012542120 0012542210 00128830630018529353 0011396395 0011396396 0011396410 0011396411 0011396412 0016733224 0016733301 00112165460011216648 0011216650 0011216651 0011396393 0011396394 0011396409 0012232192    101T 100E 100E 100E JS87 JN43-SG-2 JN43-SG-4 JN43-SG-5     JN43-SG-1 JN43-SG-3 JN43-SG-6 JS88 SOLID BLADE OPEN OPEN2 - 4.00 - PVC                              600 600 600 300 5025 25 50 50 750 50 50 50 50 50 50 50 50 50 50 25 50 50 50 25 50 25<<236139 236140 236130 236126 236127 236128 236129 236119 278044 402833 250088 250122 250123 254256 254257 263838 264385 265136265916 278041 278042 278043 378156 378159 378161 378201 402807 402810 402811 402812 402814 402815 402816 402818 402819 402820 402822 402823 402832 402834 402835 402836 402837 402838 405485                                                          VERMILLION CTCHARLOTT E C I R CHRISTIE LNGRAND PRAIRIE PKWYSE KETTLESTO N E B L V D FLEET ST S FLEET STSE KE T T L E S T O N E B L V D ESKE R R I D G E D RGRAND PRAIRIE PKWYSE PARKVIEW CROSSING DRSE E S K E R R I D G E D R UNKNOWN SE E N C O M P A S S D R 3241 3256 3242 310531221150 1240 1300 1155 3257 3261 3265 3267 3271 3273 3277 3251 325527052702 2703288525401197 2855PPP PP P P P A AAA C B B B B 1/0 AL JACKETED4/0 AL PARA1/0 AL JACKETED4/0 AL PARA1/0 AL JACKETED4/0 AL PARA 4/0 AL PARA1/0 AL JACKETED1/0 AL JACKETED750 AL PARA4/0 AL PARA1/0 AL JACKETED 4/0 A L P A R A 1/0 AL PARA1/0 AL PARA4/0 AL PARA 1/0 A L J A C K E T E D 750 AL PARA 750 AL PARA 750 AL PARA 750 AL PARA 750 AL PARA 1/0 AL JACKETED4/0 AL PARA4/0 AL PARA 1/0 AL JACKETED1/0 AL JACKETED 1/0 AL JACKETED 1/0 AL JACKETED 1/0 AL JACKETED 1/0 AL JACKETED 2 ACSR (2 ACSR )2 ACSR 6/1 (2 ACSR 6/1)2 AC S R 6 / 1 ( 2 A C SR 6 / 1 )1/0 ACSR 6/1 (1/0 ACSR 6/1)2 ACSR 6/1 (2 ACSR 6/1)2 ACSR 6/1 (2 ACSR 6/1)COMMON NEUTRAL750 AL PARA 336 ACSR 18/1 (4/0 ACSR 6/1)4/0 AL PARAEL203EL203EL203EL203EL203EL203EL203EL203EL203EL203 EL203 EL2 0 3EL203 EL203 EL2 0 3 EL203EL203 EL203 EL203 EL203 EL203EL203EL203 EL203EL203EL203 EL203 EL203 EL203 EL203 EL203EL203EL203EL203EL203 EL203 EL203UGUG UG COC UGUG COC UG COCUGCOCUGCOC UGCOCUG COC U G C O C UG COC UGCOCUG COC UG COC UGCOCUGCOC13 OF 4 / 0 U G A L T R I P L E X 69 OF 1 / 0 U G A L T R I P L E X 7 OF 1/0 UG AL TRIPLEX UG UG COC 208/120480/2 7 7 12 0 / 2 0 8 480/277 208/120 208/120208/120SIREN STLT STLT TRLTCTV                                              0018633653 0018727257 0016641956 0016643725 0016872201 0016872243 0016877685 0017023788 G360 0017237962 G361 0017237970 0017241475 0017449882 0018412188 GPP P.E. C0018592284 0018614210 GPP P.E. B 0018623943 GPP P.E. A 0018623996 0018755954 0019107081 0019135792 0016754359 0016754569 0017240601 0017685381 0017802530 0017898949 0018518541 Fleet 3 0018732578 1155 0019123013 0019123370 0019269414 SG-JC553 0019433698 PP0098 0019448968 SG-JC556 0019448975 SG-JC5540019449078 0019449109 PP0099 0019449211 0019449219 0019450278 0019450302 0019450311 0019450321 3247 Ashworth P.E. 0018624037                      65T 100E 200E 200E 30T 200E 200E 30E 30E 200E 200E 65T 65T 65T 65T 140T 140T X620 G361-2 G361-4 G361-5 JC557 SG-JC553-02 SG-JC553-06 SG-JC553-05 SG-JC553-04 SG-JC556-06 SG-JC556-04 SG-JC556-05 SG-JC556-02 SG-JC554-05 SG-JC554-02 SG-JC554-04 X617A U150 X733 X619 X028 PH37           G361-1 G361-6 G361-3 JC555 SG-JC553-01 SG-JC553-03 SG-JC556-03 SG-JC556-01 SG-JC554-03 SG-JC554-06 SG-JC554-01 MD01 MD02X626        OPEN OPEN 1 - 2.00 - CONTI NUOUS POLYETHELYNE1 - 6.00 - CONTINUOUS POLYETHELYNE1 - 4.00 - CONTINUOUS POLYETHELYNE1 - 4.00 - PVC1 - 4.00 - PVC 1 - 4.00 - CONTINUOUS POLYETHELYNE1 - 4.00 - PVC1 - 4.00 - PVC 1 - 4.00 - CON T I N U O U S P O L Y E T H E L Y N E1 - 2.00 - CONTINUOUS POLYETHELYNE1 - 6.00 - CONTINUOUS POLYETHELYNE1 - 4.00 - CONTINUOUS POLYETHELYNE1 - 2.00 - CONTINUOUS POLYETHELYNE1 - 4.00 - CONTINUOUS POLYETHELYNE1 - 4 . 0 0 - C O N T I N U O U S P O L Y E T H E L Y N E 2 - 4.00 - PVC 2 - 2 . 0 0 - C O N T I N U O U S P O L Y E T H E L Y N E 1 - 4.00 - CONTINUOUS POLYETHELYNE1 - 2.00 - CONTINUOUS POL Y E T H E L Y N E 1 - 2.00 - CONTINUOUS POL Y E T H E L Y N E 1 - 2.00 - CONTINUOUS POLYE T H E L Y N E 1 - 2.00 - CONTINUOUS POLYE T H E L Y N E 1 - 2.00 - CONTINUOUS P O L Y E T H E L Y N E 1 - 4.00 - CONTINUOUS POLYETHELYNE 1 - 6.00 - CONTINUOUS P O L Y E T H E L Y N E 1 - 4.00 - CONTINUOUS POLYETHELYNE1 - 6.00 - CONTINUOUS P O L Y E T H E L Y N E 1 - 6.00 - CONTINUOUS POLYETHELYNE 1 - 6.00 - CONTINUOUS P O L Y E T H E L Y N E 1 - 6.00 - CONTINUOUS POLYETHE L Y N E 1 - 6.00 - CONTINUOUS POLYETHELYNE                                             600 600 600 900 600 600 600 600 600 600 600 600 600 600 25 25 300 50 1500 25 1500 25 150 ABC PHS 150 KVA 208/120 500 50 C PHS 50 KVA 120/240 B PHS 25 KVA120/240 B PHS 25 KVA 120/240 B PHS 25 KVA 120/240 B PHS 25 KVA 120/240 B PHS 25 KVA120/240 B PHS 25 KVA120/240 25 25 B PHS 25KVA120/240 300 CONDUITS & TRACER WIRESTUBBED AT THIS LOCATION LOCATOR NEEDS TO LOCATETHESE CONDUITS CONDUITS & TRACER WIRESTUBBED AT THIS LOCATION LOCATOR NEEDS TO LOCATETHESE CONDUITS CONDUITS & TRACER WIRESTUBBED AT THIS LOCATION LOCATOR NEEDS TO LOCATETHESE CONDUITS <<<<<<<                                                                            SEC CAP I-80 E WENDOVER RDI-80 W I-80 E GRAND PRAIRIE PKWYGRAND PRAIRIE PKWYFLEET ST S FLEET ST330032083991047510775 33064330 6 63306510180(33160)3281310532073248PP PP P CBB 2 ACSR 6/1 (2 ACS R 6 / 1 )1/0 ACSR 6/1 (1/0 ACSR 6/1)1/0 AL JACKETE D 2 ACSR 6/1 (2 ACSR 6/1)4A COPPERWELD 3W (4A COPPERWELD 3W)2 ACS R 6/1 (2 A C S R 6/1)1/0 ACS R 6/1 (1/0 A C S R 6/1)1/0 AL JACKETED4/0 AL PARA1/0 AL JACKETED4/0 AL PARA EL203 EL203 EL203EL203 EL203 EL203EL203EL203EL203EL203U G C O C UG COC UGCOCUGCOCUG COC U G C O C UG CO C 20 8 / 1 2 0208/120480/277 480 / 2 7 7 ST L T TRLT                                                                       00166920780016712158 0016712177 0016725413 0016725416 0016725440 0016725443 0016806847 0016806850 0016979214 0017014287 0018633653 0005090915 0005090990 0005091011 0016979128 0018727250 0018727257 Fleet 10018732566 Fleet 20018732576 0018732602 0016754569 0017898949 0018518541     15T 25T R5101 X586  1 - 4.00 - PVC1 - 4.00 - PVC 1 - 4.00 - CONTINUOUS POLYETHELYNE                    25 25 25 25 25 150 25 300 1500 1000 <<<<<<<<<<< 240602 240603 240605 240608 240609 240610 240611 240612 240613 240614 240615 240617 240620 240621 240622 247098 247099 247100 247101 247104 240607 240606 240619 240616 240618 240604 240599 240600 240601 240623 240624 247106 247107 247108 247109 247110 345644 360359 CS19609                           15' UE3227 3241 3233 3242 B B 2 ACSR (2 ACSR)2 ACSR (2 ACSR)750 AL PARA 336 ACSR 18/1 (4/0 ACSR 6/1)EL203EL203EL203 EL203 EL203 UG CO C UG         SG-JC553 0019433698 0000853762 0000853763 0004032188 0016728113 V087 0016728121 0016729630 0004016235 45-3 WOOD 45-3 W OOD 45-3 WOOD 717 373 664 205      65T 65T V086 V087 SG-JC553-02 SG-JC553-06 SG-JC553-05 SG-JC553-04JC552 SG-JC553-01 SG-JC553-031 - 6.00 - CONTINUOU S P O L Y E T H E L Y N E 1 - 6.00 - CONTINUOUS POLYET H E L Y N E   900 600 600 25 <<<   6 15 16 17 19 26 53 54 65 66 83 84 96 VERMILLION CT3256 1150 3257 3261 3251 3255 P B 750 AL PARA 750 AL PARA 750 AL PARA 1/0 AL JACKETED4/0 AL PARA4/0 AL PARA 1/0 AL JACKETED1/0 AL JACKETED 1/0 AL JACKETED 1/0 AL JACKETED 1/0 ACSR 6/1 (1/0 ACSR 6/1)2 ACSR 6/1 (2 ACSR 6/1)2 ACSR 6/1 (2 ACSR 6/1)COMMON NEUTRAL750 AL PARA 336 ACSR 18/1 (4/0 ACSR 6/1)4/0 AL PARAEL203 EL203 EL203 EL203EL203EL203 EL203EL203 EL203 EL203EL203EL203 EL203 EL203UG COC UGUGCOCUGCOCU G C O C 13 OF 4 / 0 U G A L T R I P L E X COC12 0 / 2 0 8 SIREN CTV                 0016877685 0017685381 PP0098 0019448968 SG-JC556 0019448975 SG-JC554 0019449078 0019449109 PP0099 0019449211 0019449219 0019450278 0019450302 3247 Ashworth P.E. 0018624037 0000853559 0004015577 45-3 WOOD 45-3 WOOD 45-3 WOOD 45-3 WOOD 45-3 WOOD 40-4 WOOD 45-3 WOOD 35-5 WOOD 45-3 WOOD 55-1 WOOD          200E 200E 30E 30E 200E 200E 65T 65T 140T 140T SG-JC556-06 SG-JC556-04 SG-JC556-05 SG-JC556-02 SG-JC554-05 SG-JC554-02 SG-JC554-04 X617A U150 X028 PH37       SG-JC556-03 SG-JC556-01 SG-JC554-03 SG-JC554-06 SG-JC554-01 MD01 MD02X626   1 - 4.00 - CONTINUOUS POLYETHELYNE1 - 2.00 - CONTINUOUS P O L Y E T H E L Y N E 1 - 2.00 - CONTINUOUS P O L Y E T H E L Y N E 1 - 2.00 - CONTINUOUS POL Y E T H E L Y N E 1 - 4.00 - CONTINUOUS POLYETHELYNE 1 - 4.00 - CONTINUOUS POLYETHELYNE1 - 6.00 - CONTINUOU S P O L Y E T H E L Y N E 1 - 6.00 - CONTINUOUS POLYETHELYNE 1 - 6.00 - CONTINUOU S P O L Y E T H E L Y N E 1 - 6.00 - CONTINUOUS POLYETHELYNE            600 600 600 600 600 600 600 600 B PHS 25 KVA 120/240 B PHS 25 KVA 120/240 B PHS 25 KVA 120/240 B PHS 25 KVA 120/240 25 25 B PHS 25KVA 120/240 300 CONDUITS & TRACER WIRE STUBBED AT THIS LOCATION LOCATOR NEEDS TO LOCATE THESE CONDUITS CONDUITS & TRACER WIRE STUBBED AT THIS LOCATION LOCATOR NEEDS TO LOCATE THESE CONDUITS CONDUITS & TRACER WIRE STUBBED AT THIS LOCATION LOCATOR NEEDS TO LOCATE THESE CONDUITS <<<<<                     1 2 3 4 5 9 13 14 17 21 22 23 24 25 27 28 29 30 31 32 33 34 37 383940 41 43 44 48 50 51 52 53 56 59 60 61 62 63 64 66 67 68 69 70 71 73 75 76 77 78 79 80 82 83 85 86 87 88 89 90 91 92 98 100 101 102 1/0 AL JACKETED EL203 SG-JC556 0019448975 3247 Ashworth P.E. 0018624037    200E 200E 30E SG-JC556-06 SG-JC556-04 SG-JC556-05 SG-JC556-02  SG-JC556-03 SG-JC556-01 1 - 2.00 - CONTINUOUS P O L Y E T H E L Y N E 1 - 4.00 - CONTINUOUS POLYETHELYNE   600 600 CONDUITS & TRACER W IRE STUBBED AT THIS LOCATION LOCATOR NEEDS TO LOCATE THESE CONDUITS CONDUITS & TRACER W IRE STUBBED AT THIS LOCATION LOCATOR NEEDS TO LOCATE THESE CONDUITS CONDUITS & TRACER W IRE STUBBED AT THIS LOCATION LOCATOR NEEDS TO LOCATE THESE CONDUITS      25 28 41 VERMILLION CTCHRISTIE LN3256 1150 3257 3261 3265 3267 3271 3273 3277 3281 3285 3251 3255 P B B B B B 2 ACSR (2 ACSR)750 AL PARA 750 AL PARA 1/0 AL JACKETED4/0 AL PARA1/0 AL JACKETED 1/0 AL JACKETED 1/0 AL JACKETED 1/0 AL JACKETED 1/0 AL JACKETED 2 ACSR (2 ACSR )2 ACSR 6/1 (2 ACSR 6/1)2 AC SR 6 / 1 ( 2 AC SR 6 / 1 )1/0 ACSR 6/1 (1/0 ACSR 6/1)2 ACSR 6/1 (2 ACSR 6/1)2 ACSR 6/1 (2 ACSR 6/1)COMMON NEUTRAL4/0 AL PARAEL203EL203 EL203 EL203EL203EL203 EL203 EL203 EL203 EL203 EL203EL203EL203EL203EL203UGUG UG COC U G C O C 13 OF 4 / 0 U G A L T R I P L E X 69 O F 1 / 0 U G A L T R I P L E X 7 OF 1/0 UG AL TRIPLEX UG UG COC12 0 / 2 0 8 SIREN CTV                          0017685381 SG-JC554 0019449078 0019449109 0019450278 0019450302 0019450311 0019450321 0000853549 0000853550 0000853559 0004015577 0012752772 X611 0016728826 45-3 WOOD 45-3 WOOD45-3 WOOD 45-3 WOOD 45-3 WOOD 35-5 WOOD 45-3 WOOD 0000853502 40-4 WOOD 35-5 WOOD 40-4 WOOD X619 0016728809 X620 0016728816 55-1 WOOD             65T 65T 30T 30E 200E 200E 65T 65T 65T 65T 140T 140T X620 X611 JC557 SG-JC556-06 SG-JC554-05 SG-JC554-02 SG-JC554-04 X617A U150 X733 X619 X028 PH37      JC555 SG-JC556-01 SG-JC554-03 SG-JC554-06 SG-JC554-01  OPEN 1 - 2.00 - CONTINUOUS P O L Y E T H E L Y N E 1 - 2.00 - CONTINUOUS P O L Y E T H E L Y N E 1 - 2.00 - CONTINUOUS PO L Y E T H E L Y N E 1 - 2.00 - CONTINUOUS PO L Y E T H E L Y N E 1 - 2.00 - CONTINUO U S P O L Y E T H E L Y N E 1 - 6.00 - CONTINUO U S P O L Y E T H E L Y N E 1 - 4.00 - CONTINUOUS POLYETHELYNE1 - 6.00 - CONTINUOU S P O L Y E T H E L Y N E          900 600 600 600 25 B PHS 25 KVA 120/240 B PHS 25 KVA 120/240 B PHS 25 KVA 120/240 B PHS 25 KVA 120/240 B PHS 25 KVA 120/240 25 300 <<<<<<<               1 4 5 7 8 9 10 11 12 14 18 20 23 24 29 30 33 34 35 36 38 43 44 45 46 47 49 50 52 55 56 57 58 59 60 61 67 70 71 72 74 76 77 78 81 82 86 87 91 92 93 94 95 97 98 99 100 101 102 103 104 3227 3241 3233 3242 B 2 ACSR (2 ACSR)750 AL PARA 750 AL PARA 1/0 AL JACKETEDEL203EL203 EL203 EL203UG CO C UGUGCOCUGCOC     0016877685 SG-JC553 0019433698 PP0098 0019448968 PP0099 0019449211 0019449219 0000853762 0000853763 0004032188 V087 0016728121 0016729630 0004016235    65TV087 SG-JC553-02 SG-JC553-06 SG-JC553-05 SG-JC553-04JC552 SG-JC553-01 SG-JC553-03 1 - 6.00 - CONTINUOUS POLYETHELYNE 1 - 6.00 - CONTINUOU S P O L Y E T H E L Y N E 1 - 6.00 - CONTINUOUS POLYET H E L Y N E      900 600 600 B PHS 25 KVA 120/240 <<<       VERMILLION CT3256 1150 3257 3261 3265 3267 3271 3273 3277 3251 3255 P B 750 AL PARA 750 AL PARA 750 AL PARA 1/0 AL JACKETED4/0 AL PARA4/0 AL PARA 1/0 AL JACKETED1/0 AL JACKETED 1/0 AL JACKETED 1/0 AL JACKETED 1/0 AL JACKETED 1/0 AL JACKETED EL203 EL203 EL203 EL203EL203EL203 EL203EL203 EL203 EL203 EL203 EL203 UG UG COC UGCOCUGCOCU G C O C 13 OF 4 / 0 U G A L T R I P L E X 69 O F 1 / 0 U G A L T R I P L E X UG UG COC12 0 / 2 0 8 SIREN CTV            0016877685 0017685381 PP0098 0019448968 SG-JC556 0019448975 SG-JC554 0019449078 0019449109 PP0099 0019449211 0019449219 0019450278 0019450302 0019450311 0019450321 0000853559 0004015577 0000853502 X619 0016728809       200E 200E 30E 30E 200E 200E JC557 SG-JC556-06 SG-JC556-04 SG-JC556-05 SG-JC556-02 SG-JC554-05 SG-JC554-02 SG-JC554-04      JC555 SG-JC556-03 SG-JC556-01 SG-JC554-03 SG-JC554-06 SG-JC554-01  OPEN 1 - 2.00 - CONTINUOUS P O L Y E T H E L Y N E 1 - 2.00 - CONTINUOUS P O L Y E T H E L Y N E 1 - 2.00 - CONTINUOUS POL Y E T H E L Y N E 1 - 2.00 - CONTINUOUS PO L Y E T H E L Y N E 1 - 2.00 - CONTINUO U S P O L Y E T H E L Y N E 1 - 4.00 - CONTINUOUS POLYETHELYNE 1 - 6.00 - CONTINUOU S P O L Y E T H E L Y N E 1 - 4.00 - CONTINUOUS POLYETHELYNE1 - 6.00 - CONTINUOU S P O L Y E T H E L Y N E 1 - 6.00 - CONTINUOUS POLYETHELYNE               900 600 600 600 600 600 B PHS 25 KVA B PHS 25 KVA 120/240 B PHS 25 KVA 120/240 B PHS 25 KVA 120/240 B PHS 25 KVA 120/240 B PHS 25 KVA 120/240 300 CONDUITS & TRACER WIRE STUBBED AT THIS LOCATION LOCATOR NEEDS TO LOCATE THESE CONDUITS CONDUITS & TRACER WIRE STUBBED AT THIS LOCATION LOCATOR NEEDS TO LOCATE THESE CONDUITS CONDUITS & TRACER WIRE STUBBED AT THIS LOCATION LOCATOR NEEDS TO LOCATE THESE CONDUITS <<                       3227 3241 3233 3242 B 2 ACSR (2 ACSR)750 AL PARA 336 ACSR 18/1 (4/0 ACSR 6/1)EL203EL203 UG CO C UGUGCOCUGCOC        0016877685 0000853762 0000853763 0004032188 V087 0016728121 0016729630 0004016235 45-3 WOOD 45-3 WOOD 45-3 WOOD 45-3 WOOD 40-4 WOOD65TV087  MD01 600 25 B PHS 25KVA 120/240 <<VERMILLION CT3256 1150 3257 3261 3265 3267 3271 3273 3277 3251 3255 P B B B B 2 ACSR 6/1 (2 ACSR 6/1)2 AC SR 6 / 1 ( 2 ACSR 6 / 1 )1/0 ACSR 6/1 (1/0 ACSR 6/1)2 ACSR 6/1 (2 ACSR 6/1)2 ACSR 6/1 (2 ACSR 6/1)COMMON NEUTRAL750 AL PARA 4/0 AL PARAEL203EL203EL203EL203 EL203UG UG COC UGCOCUGCOCU G C O C UG UG COC12 0 / 2 0 8 SIREN CTV                    0016877685 0017685381 3247 Ashworth P.E. 0018624037 0000853559 0004015577 45-3 WOOD 45-3 WOOD45-3 WOOD 45-3 WOOD 45-3 WOOD 40-4 WOOD 45-3 WOOD 35-5 WOOD 45-3 WOOD 0000853502 40-4 WOOD 35-5 WOOD 40-4 WOOD X619 0016728809 55-1 WOOD       65T 65T 65T 65T 140T 140T X617A U150 X733 X619 X028 PH37 MD02X626     600 600 25 B PHS 25KVA 120/240 300 CONDUITS & TRACER WIRE STUBBED AT THIS LOCATION LOCATOR NEEDS TO LOCATE THESE CONDUITS CONDUITS & TRACER WIRE STUBBED AT THIS LOCATION LOCATOR NEEDS TO LOCATE THESE CONDUITS CONDUITS & TRACER WIRE STUBBED AT THIS LOCATION LOCATOR NEEDS TO LOCATE THESE CONDUITS <<<<<      pw://PW-APS1.foth.com:PW_IE/Documents/Clients/Waukee IA C/SE Ashworth Road Corridor Improvements/CAD/Plans/0019W019.01_D2_SHTCLIENT PROJECT NO: DESIGNED BY: PROJECT DATE: CAD FILE: CHECKED BY: CAD DATE: c:\pw_workdir\pw_ie\fvd_axc2\d0382026\0019W019.01_D2_SHT.dgn 9/10/2020 DRAWN BY: 1:20:49 PM FOTH PROJECT NO:NO DATE BY REVISION DESCRIPTION SHEET NO. UB UB UV MB MB MB SIGN SIGN SIGN STOP UB UB WV CPF CPS WV WV15 0+00155+00148+00149+00151+00152+00153+00154+00156+00157+002300.00'R 3.508'E 253.90'L 127.08'T 02°29'28.0"D (RT)06°19'29.9"Δ 150+44.92PI 2300.00'R 3.508'E 253.90'L 127.08'T 02°29'28.0"D (LT)06°19'29.9"Δ 152+98.82PI 151+71.74 PRC154+25.64 PT149+17.84 PC151+71.74 PRC150+44.92PI 152+98.82PI OAKLEAF PROPERTIES LC 7929 ASHWORTH ROAD 56 GOODALL, CHARLES 3227 ASHWORTH 19 GOODALL, CHARLES 3233 ASHWORTH 20 21 ARAC LLC SE ASHWORTH ROAD SE PARKVIEWCROSSING DRIVEBOONE TWP R-26W T-78N SECTION 4 BOONE TWP R-26W T-78N SECTION 9 GRADING LIMITS PROPOSED 16" WATER MAIN PROPOSED 8" WATER MAIN SEE K SHEETS FOR INFORMATION BEGIN TEMPORARY WIDENING 154+25.64STA BEGIN CONSTRUCTION STA 708+15.13 (SE PARKVIEWCROSSING DR) (SE ASHWORTH RD)156+41.09STA 149+00 150+00 151+00 152+00 153+00 154+00 155+00 156+00 157+00 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 1000 1000 1005 1005 1010 1010 1015 1015 1020 1020 1025 1025 1030 1030 1035 1035 1040 1040 +1.00% 125K = 200.00'LEN 1026.99'ELV 156+50.00VPI 1025.99EL 155+50.00VPC 1026.62EL 156+75.00HP 1024.991025.491025.991026.391026.591026.591025.241025.741026.221026.521026.621026.52PROPOSED PROFILE GRADE EXISTING GROUND @ � SE ASHWORTH RD 1024.75ELEV 154+25.64STA BEGIN CONSTRUCTION SEE K SHEETS FOR PROFILE INFORMATION +25 D.2A. SCHOTT A. FLOY A. COLON SUBJECT TO CHANGE SE ASHWORTH ROAD PLAN AND PROFILE 0019W019.01 DECEMBER 2020 SE ASHWORTH ROAD CORRIDOR IMPROVEMENTS SE PARKVIEWCROSSING DRIVE TO SE GLACIER TRAIL WAUKEE, IA 0 30 FEETInstall guy & riser for OH2UG Please provide desired cable depth to avoid conflict with storm and grading. 1 Ph 1/0 Cable in 2" conduit 3 Ph 1/0 Cable in 4" conduit 3 Ph 750 Feeder Cable in 4" conduit Existing Ground = 1016.79' FL Storm =1010.95' Top of Cable = 1008.95' Existing Ground = 1023.61' Bottom JUT = 1021.43' Top of Cable = 1019.43' Existing Ground = 1024.95' Bottom JUT = 1021.46' Top of Cable =1019.46'Avoid existing 8" water main (roughly 5.5' from existing ground to top of pipe) pw://PW-APS1.foth.com:PW_IE/Documents/Clients/Waukee IA C/SE Ashworth Road Corridor Improvements/CAD/Plans/0019W019.01_D2_SHTCLIENT PROJECT NO: DESIGNED BY: PROJECT DATE: CAD FILE: CHECKED BY: CAD DATE: c:\pw_workdir\pw_ie\fvd_axc2\d0382026\0019W019.01_D2_SHT.dgn 9/10/2020 DRAWN BY: 1:20:57 PM FOTH PROJECT NO:NO DATE BY REVISION DESCRIPTION SHEET NO. WV UV UV UV UV UV UV UV UV WV WV UB WV WV WV WV GV WV WV WV SIGN SIGN SIGN UB WV WV WV WV WV WV WV WV GV UV UV UV WVWV RT WV CPS CLN OUT160+00165+00157+00158+00159+00161+00162+00163+00164+00166+00HDANK INVESTMENT, LLC 57 OAKLEAF PROPERTIES LC 7929 ASHWORTH ROAD 56 ARAC LLC 22 SE ASHWORTH ROAD GRAND PRAIRIE PARKWAYBOONE TWP R-26W T-78N SECTION 4 BOONE TWP R-26W T-78N SECTION 4 BOONE TWP R-26W T-78N SECTION 9 GRADING LIMITS STA 811+18.91 (GRAND PRAIRE PKWY) (SE ASHWORTH RD)166+32.31STA 165+33.23STA END CONSTRUCTION 158+00 159+00 160+00 161+00 162+00 163+00 164+00 165+00 166+00 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 1000 1000 1005 1005 1010 1010 1015 1015 1020 1020 1025 1025 1030 1030 1035 1035 1040 1040 -0.60% +0.90% 100K = 150.00'LEN 1024.89'ELV 160+00.00VPI 1026.39EL 157+50.00VPT 1025.34EL 159+25.00VPC 1025.57EL 160+75.00VPT 1025.16EL 159+85.00LP 1026.391026.091025.791025.491025.221025.171025.371025.791026.241026.691027.141027.591028.041028.491028.941029.391029.691029.69EL 165+33.23VPI 1026.521026.241025.941025.641025.341025.171025.241025.571026.021026.471026.921027.371027.821028.271028.721029.171029.62PROPOSED PROFILE GRADE EXISTING GROUND @ � SE ASHWORTH RD +25 D.3A. SCHOTT A. FLOY A. COLON SUBJECT TO CHANGE SE ASHWORTH ROAD PLAN AND PROFILE 0019W019.01 DECEMBER 2020 SE ASHWORTH ROAD CORRIDOR IMPROVEMENTS SE PARKVIEWCROSSING DRIVE TO SE GLACIER TRAIL WAUKEE, IA 0 30 FEET Install 6-Bay SG in 20'x30' MEC easement. - Customer to ensure easement area is to final grade before MEC installation and does not conflict with City construction. - Confirm location is not in a water-way as aerial map shows. Will these UG cables be relocated? 600A enclosure in 20'x10' MEC easement. Customer to ensure area is brought to final grade before MEC installation and will not conflict with city construction. Install 1 Ph transformer Does City of Waukee still need power here? Install transformer in ROW/PUE if so 20.73 ft 92.69 ft Existing Ground = 1027.20' Bottom of JUT = 1023.14' Top of Cable = 1021.14' Existing Ground = 1027.91' Bottom JUT = 1023.41' Top of Cable =1021.41' pw://PW-APS1.foth.com:PW_IE/Documents/Clients/Waukee IA C/SE Ashworth Road Corridor Improvements/CAD/Plans/0019W019.01_D2_SHTCLIENT PROJECT NO: DESIGNED BY: PROJECT DATE: CAD FILE: CHECKED BY: CAD DATE: c:\pw_workdir\pw_ie\fvd_axc2\d0382026\0019W019.01_D2_SHT.dgn 9/10/2020 DRAWN BY: 1:21:03 PM FOTH PROJECT NO:NO DATE BY REVISION DESCRIPTION SHEET NO. WV WV UB UB GV UB UV WV WV UB WV WV UB SIGN SIGN MBMB WV UB WV SB SB SB SBSB SB SBSB SB SBSB SBSBSBSB SB SB GV SB SB SB SB SB SB SB UB SB SB SB SB SB SB SB UB SB SBSB SB SB WV CPS UB SB SBSB SB SB SBSBSB SBSB SB SB SB SBSBSB SB SB SB SB SB SB SB SB SB GW RT UV WV WV GW CLN OUT CLN OUT WV WV170+00175+00167+00168+00169+00171+00172+00173+00174+00AP GPP LC 1150 SE ASHWORTH 59 AP GPP LC 58 ARAC, LLC 23 24 ARAC, LLC 3251 ASHWORTH 25 HOLTHAUS, BENJAMIN P & WANDA 3255 ASHWORTH FETTERS, TONY 3257 ASHWORTH 26 LOVE, WILLIAM & DONNA 3261 ASHWORTH 27 FARMLAND RESERVE INC 60 SE ASHWORTH ROADGRAND PRAIRIE PARKWAYSE VERMILLION COURTBOONE TWP R-26W T-78N SECTION 4 BOONE TWP R-26W T-78N SECTION 9 GRADING LIMITS PROPOSED 18" SANITARY SEWER PROPOSED 16" WATER MAIN 167+32.24STA BEGIN CONSTRUCTION STA 811+18.91 (GRAND PRAIRIE PKWY) (SE ASHWORTH RD)166+32.39STA STA 913+47.17 (SE VERMILLION CT) (SE ASHWORTH RD)173+50.24STA 167+00 168+00 169+00 170+00 171+00 172+00 173+00 174+00 175+00 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 1000 1000 1005 1005 1010 1010 1015 1015 1020 1020 1025 1025 1030 1030 1035 1035 1040 1040 -1.97% PROPOSED PROFILE GRADE EXISTING GROUND @ � SE ASHWORTH RD +50 -0.60%+0.60% 117K = 300.00 FTLEN 1030.64ELV 173+00.00VPI 125K = 150.00 FTLEN 1028.54ELV 169+50.00VPI 1029.74ELV 171+50.00VPC 1027.68ELV 174+50.00VPT 1028.99ELV 168+75.00VPC 1028.99ELV 170+25.00VPT 1028.77ELV 169+50.00LP 1029.95ELV 172+19.92HP 1029.851029.741029.441029.141028.871028.771028.871029.141029.441029.741029.941029.911029.681029.231028.561027.681026.691025.711029.85ELV 167+32.22VPI 1029.851029.591029.291028.991028.791028.791028.991029.291029.591029.871029.951029.821029.481028.921028.151027.191026.20D.4A. SCHOTT A. FLOY A. COLON SUBJECT TO CHANGE SE ASHWORTH ROAD PLAN AND PROFILE 0019W019.01 DECEMBER 2020 SE ASHWORTH ROAD CORRIDOR IMPROVEMENTS SE PARKVIEWCROSSING DRIVE TO SE GLACIER TRAIL WAUKEE, IA 0 30 FEET Install 1 Ph Transformer in PUE to serve customers. Confirm location. Install 6-Bay SG in 20'x30' MEC easement. - Prefer easement parallel to Ashworth rather than SE Vermillion. Clarify black dashed lines: Is this City PUE? Does MEC equipment need to be set back out of this area? - Do you know if the Mediacom cabinet needs power or will be relocated? - Will the siren need power or will it be relocated? 600A enclosure in PUE existing 200A enclosure in PUE Existing 1 Ph UG cable to remain in place. Contractor work around? Does MEC need to pothole? Please provide desired cable depth to avoid conflict with storm and grading. Please provide desired cable depth to avoid conflict with joint utility trench Please provide contact for MEC to work with owner of Sanitary Easement. MEC would like to encroach on north 5' for E/W cable run. Existing Ground = 1029.00' FL Storm Sewer = 1021.62' Top of Cable = 1019.62' 154.056 ft 301.584 ft Maintain depth of 7' below existing ground Maintain depth of 6' below existing ground Existing Ground = 1027.23' Bottom JUT = 1024.01' Top of Cable =1021.23' Existing Ground = 1028.22' Bottom JUT = 1023.95' Top of Cable =1021.45' Avoid existing 8" water main (roughly 5.5' from existing ground to top of pipe) To ensure these lines are not disturbed by subgrade prep MEC should pothole this line because we are planning to core out soil to a depth of 3.33' below the proposed top of pavement. In this area the core out will reach down to an elevation of roughly 1025.00'. Top of Cable = 1023.00' under proposed pavement pw://PW-APS1.foth.com:PW_IE/Documents/Clients/Waukee IA C/SE Ashworth Road Corridor Improvements/CAD/Plans/0019W019.01_D2_SHTCLIENT PROJECT NO: DESIGNED BY: PROJECT DATE: CAD FILE: CHECKED BY: CAD DATE: c:\pw_workdir\pw_ie\fvd_axc2\d0382026\0019W019.01_D2_SHT.dgn 9/10/2020 DRAWN BY: 1:21:10 PM FOTH PROJECT NO:NO DATE BY REVISION DESCRIPTION SHEET NO. UB MBMB MB MB MB MB MB MB UB GW 180+00176+00177+00178+00179+00181+00182+00183+00184+002300.00'R 3.508'E 253.90'L 127.08'T 02°29'28.0"D (LT)06°19'29.9"Δ 182+69.43PI 181+42.35 PC183+96.25 PRC183+96.25 PRC182+69.43PI FARMLAND RESERVE INC 60 HERRIDGE, DONALD C 3271 ASHWORTH 30 HARCEY, JON A & ANDREA F 3267 ASHWORTH 29 BROCKMAN, LOUIS W & GRETCHEN A 3265 ASHWORTH 28 DOLMAGE, DENNIS D & CYNTHIA S 3273 ASHWORTH 31 SWEENEY, RONALD M & CANDACE A 3277 ASHWORTH 32 GRANBERG, GERALD ALLAN & DIANNA LEE 3281 ASHWORTH 33 HOSIER, RITA J 3285 ASHWORTH 34 SE ASHWORTH ROADSE GLACIER TRAILBOONE TWP R-26W T-78N SECTION 4 BOONE TWP R-26W T-78N SECTION 9 GRADING LIMITS PROPOSED 18" SANITARY SEWER PROPOSED 16" WATER MAIN PROPOSED 18" SANITARY SEWER 177+36.39STA BEGIN WIDENING END CONSTRUCTION 180+94.54STA END WIDENING STA 906+11.81 (SE GLACIER TRL) (SE ASHWORTH RD)178+85.50STA 176+00 177+00 178+00 179+00 180+00 181+00 182+00 183+00 184+00 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 +50 +75 +25 995 995 1000 1000 1005 1005 1010 1010 1015 1015 1020 1020 1025 1025 1030 1030 1035 1035 PROPOSED PROFILE GRADE EXISTING GROUND @ � SE ASHWORTH RD +50 -1.97% 109K = 150.00 FTLEN 1013.86ELV 181+50.00VPI 1015.34ELV 180+75.00VPC 1013.41ELV 182+25.00VPT 1025.711024.721023.731022.751021.761020.771019.781018.801017.811016.821015.831014.881014.121013.591013.261012.961012.661012.361012.061025.211024.231023.241022.251021.261020.281019.291018.301017.321016.331015.341014.471013.821013.411013.111012.811012.511012.21D.5A. SCHOTT A. FLOY A. COLON SUBJECT TO CHANGE SE ASHWORTH ROAD PLAN AND PROFILE 0019W019.01 DECEMBER 2020 SE ASHWORTH ROAD CORRIDOR IMPROVEMENTS SE PARKVIEWCROSSING DRIVE TO SE GLACIER TRAIL WAUKEE, IA 0 30 FEETInstall guy & riser for OH2UG Install guy and 1 Ph riser to loop feed customers From:Floy, Andy To:Christopher, Janice (MidAmerican) Cc:Enger, Scot (MidAmerican); Soumare, Hamou (MidAmerican) Subject:[INTERNET] RE: MEC crossing Date:Friday, February 12, 2021 1:40:43 PM Attachments:image003.png image004.png image005.png * * Remember SAIL when reading email * * Are you expecting the message from this SENDER ? Are you expecting an ATTACHMENT ? Does the message subject include INTERNET ? Verify LINKS before clicking. Janice,   I’m not sure you have our final plan set so I’m having someone send it along.  This storm sewer is 18” diameter.  The top of pipe in this area is around 1023 and the proposed ground elevation is around 1029.  In theory it would work to go above the pipe, but I would shoot for 1024’-1025’ to give some room between your line and the new pipe.  Our contractor will be digging this area up to install the pipe after you are finished so we need to make sure the new line is completely above the pipe.   Andy Floy, Lead Civil Engineer Licensed in IA, KS, MO Foth Infrastructure & Environment, LLC 8191 Birchwood Court, Suite L Johnston, IA 50131 Ph:  (515) 254-1393 Direct: (515) 251-2594 / Cell: (913) 433-3678www.foth.com   From: Christopher, Janice (MidAmerican) <Janice.Christopher@midamerican.com>  Sent: Friday, February 12, 2021 11:35 AM To: Floy, Andy <Andy.Floy@foth.com>; Nathan T. Hardisty <nhardisty@shive-hattery.com> Cc: Enger, Scot (MidAmerican) <Scot.Enger@midamerican.com>; Soumare, Hamou (MidAmerican) <Hamou.Soumare@midamerican.com> Subject: MEC crossing   Hello,   I have a question about the UG cable crosing Ashworth just east of Grand Prairie Pkwy.   How big is the storm sewer pipe?  Can we bore in above the storm sewer between elevations of 1023’ – 1024'?     Janice Christopher Electric Distribution Engineer jmchristopher@midamerican.com 515-242-3494 (Office) 515-401-2363 (Cell) 10510 Douglas Ave Urbandale, Iowa 50322