Loading...
HomeMy WebLinkAbout2021-04-19-I07 Timber Creek Plat 1_Preliminary Plat AGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: April 19, 2021 AGENDA ITEM: Consideration of approval of a resolution approving a preliminary plat for Timber Creek Plat 1 FORMAT: Resolution SYNOPSIS INCLUDING PRO & CON: The applicant is requesting approval of a preliminary plat for a 17.76-acre residential development located north of Ashworth Road and east of R-22/Ute Avenue. The plat includes nine (9) lots for single family residential development. The lots range in size from 0.75- acre to 3.23-acres in area. All lots will be served by public utilities. A number of Outlots are identified on the preliminary plat for various purposes. Outlots A, B and C are within the 100-year floodplain and will be owned by the adjoining lot owners. Outlot Z will be utilized for stormwater management. Outlot Y will have the existing horse barn located on it. Timber Creek Lane will provide access to each lot and is shown to be 26- feet in width and will end in a cul-de-sac. As part of the rezoning process for this development, a Planned Development was approved to address two unique components of this development. The first reason was the use of the existing horse barn within Outlot Y. The Planned Development includes a provision to prohibit commercial use of the barn. The second reason for the Planned Development was to address the proposal to have an access gate across Timber Creek Lane. The Planned Development includes provisions to require specific design standards of the street and to require that emergency access into the development be coordinated with Waukee Police and Fire Departments. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning Commission reviewed the request at their meeting on April 13, 2021, recommended approval subject to remaining staff comments: Approval of a Preliminary Plat for Timber Creek Plat 1 City of Waukee Senior Planner, Andy Kass, introduced the request for approval of a Preliminary Plat for a residential development as submitted by the applicant, 31495 Ashworth Road, LLC. I7 The subject property is generally located north of Ashworth Drive and east of R-22/Ute Avenue, containing approximately 17.76 acres. The property was recently rezoned from A-1 to R-1/PD in 2021. Mr. Kass advised that the preliminary plan identifies a total of nine lots intended for single family residential development, ranging in size from 0.75 acres to 3.23 acres in area. The existing home on the property will remain and be located on lot 6. Outlots A, B, and C are areas within the 100 year floodplain and will be owned by the adjoining lot owner. Outlot Y is 2.15 acres in area with an existing horse barn. The barn will not be used for commercial or agricultural purposes, and maintenance of the outlot and buildings will be owned jointly by the owners of lots 6 and 7. Mr. Kass advised that the planned development was included for two reasons. First, in order to address the shared use of the existing horse barn shown on Outlot Y, and second to address the request for a private street instead of a public street in order to place a gate at the entrance of the development, which would be owned and maintained by the Homeowner’s Association. In exchange, the City has requested that the private street will be designed to a public street standard, a sidewalk will be provided on at least one side of the private street, appropriate street lighting will be required, emergency access for the Waukee Police and Fire Departments to the entrance gate along Ashworth road, and a public ingress/egress easement to provide access to maintain City utilities that serve the site. Mr. Kass explained that storm water detention will be provided within Outlot Z, which will be owned and maintained by the Homeowner’s Association. Public utilities will be available to the site, and a 10 foot wide trail is anticipated along Ashworth road when a widening project is constructed by the city. The trail construction covers part of the required parkland dedication, with the remaining balance proposed to be satisfied with a fee in lieu of additional land. Staff would recommend approval of the preliminary plat for Timber Creek Plat 1 subject to any remaining staff comments.  Commissioner Koshy questioned if the storage area (outlot Y) was a separate parcel from the rest of the development. Mr. Kass advised that right now, the area is all one parcel. For any future changes of the Outlot Y, there would need to be an amendment to the maintenance agreement between the owners of lots 6 and 7. Commissioner Inman moved to approve the Preliminary Plat for Timber Creek Plat 1 subject to any remaining staff comments. The motion was seconded by commissioner Broderick. Ayes: Streit, Koshy, Inman, Ward, Broderick, and Hoifeldt. Nays: None. Motion Carries. STAFF REVIEW AND COMMENT: Staff’s position is that the proposed preliminary plat meets the intent and the requirements of the Zoning Ordinance and the Waukee Subdivision Ordinance. Staff is working with the applicant to address the last few remaining comments related to the preliminary plat. RECOMMENDATION: Staff recommends approval of the Preliminary Plat for Timber Creek Plat 1 subject to remaining staff comments. ATTACHMENTS: I. Resolution II. Staff Report III. Preliminary Plat PREPARED BY: Andy Kass, Senior Planner REVIEWED BY: PUBLIC NOTICE INFORMATION – NAME OF PUBLICATION: DATE OF PUBLICATION: THE CITY OF WAUKEE, IOWA RESOLUTION 2021- APPROVING THE TIMBER CREEK PLAT 1 PRELIMINARY PLAT IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission reviewed and recommended approval of a Preliminary Plat for Timber Creek Plat 1 on April 13, 2021; AND, WHEREAS, the Preliminary Plat for Timber Creek Plat 1 is in general conformance with section §303 - Land Subdivision Ordinance of the Waukee Municipal Code. NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this the 19th day of April, 2021 that the Preliminary Plat for Timber Creek Plat 1 be approved subject to remaining staff comments. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Anna Bergman Pierce R. Charles Bottenberg Chris Crone Larry R. Lyon Ben Sinclair PLANNING AND ZONING COMMISSION STAFF REPORT PROJECT: Timber Creek Plat 1 – Preliminary Plat PREPARED BY: Andy Kass AICP, Senior Planner REPORT DATE: April 9, 2021 MEETING DATE: April 13, 2021 GENERAL INFORMATION Applicant: 31495 Ashworth Road, LLC Owner: 31495 Ashworth Road, LLC Owner’s Representative: Eric Cannon, P.E. with Snyder & Associates, Inc. Request: The applicant is requesting approval of a preliminary plat for a single-family residential subdivision. Location and Size: Property is generally located north of Ashworth Drive and east of R-22/Ute Avenue, containing approximately 17.76-acres. AREA MAP ABOVE: Aerial of Property identifying the proposed plat (outlined in RED). April 9, 2021 2 of 3 LAND USES AND ZONING Location Existing Land Use Comprehensive Plan Current Zoning Property in Question Existing Acreage Single Family Residential R-1 (Single Family Residential District) / PD-1 (Planned Development Overlay District) North Single Family Single Family Residential Dallas County South Single Family Rural Residential Dallas County East Timberline Campground Park Dallas County West Existing Acreage & El Dorado Hills Plat 1 Single Family Residential A-1 (Agricultural District) & R-1 (Single Family Residential) HISTORY The Commission recently reviewed a rezoning required of the subject property at their meeting on January 26, 2021. The Commission recommended approval of the request to rezone the property from A-1 to R-1/PD-1. The City Council approved the rezoning at their meeting on March 1, 2021. PROJECT DESCRIPTION LOTS The preliminary plat identifies a total of nine (9) lots that are intended for single family residential development. The lots will be developed in one phase. The lots range in size from 0.75-acre to 3.23-acres in area. The existing home on the property that will remain and be located on Lot 6. Outlots A, B, and C are areas within the 100-year floodplain that will be owned by each adjoining lot owner. Outlot Y is 2.15-acres in area and has an existing horse barn located on it. The barn will not be utilized for commercial or agricultural purposes, but will be owned jointly by the owners of Lots 6 and 7 for storage. The bulk regulations for the R-1/PD-1 zoning district are included below in Table 1. All proposed lots comply with the regulations of the proposed R-1/PD-1 district. Table 1: R-1/PD-1 requirements. Category Proposed R-1/PD-1 (minimum) Lot Area 30,000 square feet Lot Width 100 feet Front Yard Setback 50 feet Rear Yard Setback 35 feet Side Yard Setback 25 feet The Planned Development was included for two reasons. The first reason is to address the shared use of the existing horse barn shown on Outlot Y. The Planned Development includes a provision to prohibit commercial use of the barn. April 9, 2021 3 of 3 The second purpose was to address the request of a private street instead of a public street. Provisions related to the private street were included within the Planned Development to address emergency access and street design. The provisions include the following:  The private street shall be designed to a public street standard as is defined within the Waukee Subdivision Ordinance and Waukee Standard Specifications for Public Improvements  Sidewalk shall be provided on at least one side of the private street  Appropriate street lighting shall be provided in order to create a safe and secure environment for the residents within the development  Emergency access as approved by the Waukee Police and Fire Departments shall be provided to the entrance gate along Ashworth Road  A public ingress/egress easement shall be provided to allow for emergency access and for maintenance of City utilities STREETS AND TRAIL As indicated above, the proposed street, Timber Creek Lane, will be a private street. The street is proposed to be 26- feet in width, which is consistent with the minimum width required of a public street. At the intersection with Ashworth Road, the preliminary plat identifies an access gate. Emergency service access will need to be coordinated with the Waukee Fire and Police Departments prior to the installation of the gate. A 5-foot sidewalk is shown on both sides of the street. A 10-foot trail along Ashworth Road will be installed in the future when a widening project is constructed by the City. UTILITIES Public utilities will service the proposed development. Sanitary sewer is available along Ashworth Road and will be extended into the development. As part of future intersection improvements to R-22 and Ashworth Road, the City, will extend a public water main across the frontage of this property that a connection to service the proposed lots will be made. Stormwater detention for the project will be provided within Outlot Z, which will be owned and maintained by the homeowners association. EASEMENTS All proposed easements have been indicated on the preliminary plat. Landscape buffer easements have been indicated Along Outlot Z adjacent to Ashworth Road. PARKLAND DEDCIATION Parkland dedication requirements will apply to the project because of its residential nature. The required amount of parkland is 0.18-acre. The applicant has proposed to satisfy the remaining balance of parkland with a fee in lieu of additional land dedication. STAFF RECOMMENDATION All proposed lots meet the minimum requirements of the Zoning Ordinance and Planned Development, the preliminary plat is in general conformance with the Subdivision Ordinance, and the proposed land use of the property is consistent with the Comprehensive Plan. Staff recommends approval of the preliminary plat for Timber Creek Plat 1 subject to remaining staff comments. PRELIMINARY PLAT TIMBER CREEK PLAT 1 CITY OF WAUKEE, DALLAS COUNTY, IOWA VICINITY MAP PROJECT LOCATION NOT TO SCALE OWNER / DEVELOPER 31495 ASHWORTH ROAD LLC 1680 SW ANKENY RD, SUITE 1B ANKENY, IA 50023 CONTACT: NICK JENSEN BYDATEREVISIONMARKScale:Technician:T-R-S:SNYDER & ASSOCIATES, INC. |Checked By:Engineer:Date:1" =Project No:SheetProject No: Sheet 2727 S.W. SNYDER BLVDANKENY, IOWA 50023515-964-2020 | www.snyder-associates.comEDCJWMKMM02-15-21 120.0259.01C100120.0259.01 C100TIMBER CREEK PLAT 1PRELIMINARY PLAT - TITLE SHEETWAUKEE, IAREVISED AS PER CITY COMMENTSREVISED AS PER CITY COMMENTSREVISED AS PER CITY COMMENTSREVISED AS PER CITY COMMENTS3-2-213-16-213-30-214-6-21JWMJWMJWMJWM1234TTN-RRW-SSV:\Projects\2020\120.0259.01\CADD\1200259_PPT.dwg JEREMY W MCCORMICK, PRELIMINARY PLAT - TITLE SHEET, 2021/04/06, 1:10 PM, ANSI FULL BLEED D (34.00 X 22.00 INCHES)ENGINEER SNYDER AND ASSOCIATES, INC 2727 SNYDER BLVD. ANKENY, IA 50023 CONTACT: ERIC CANNON INDEX OF SHEETS C100 PRELIMINARY PLAT - TITLE SHEET C200 PRELIMINARY PLAT - PROJECT INFORMATION C201 PRELIMINARY PLAT- EXISTING SITE SURVEY & DEMOLITION PLAN C300 PRELIMINARY PLAT - LAYOUT PLAN C400 PRELIMINARY PLAT - UTILITY PLAN C500 PRELIMINARY PLAT - GRADING EROSION CONTROL PLAN C600 PRELIMINARY PLAT - LANDSCAPE BUFFER PLANUTE AVE ASHWORTH RD SUGAR CREEK LNSILVERLEAF LN DAYBREAK DR JACKPINE DRWHITEPINE CTCATERINE CTTIMBER CREEK LANE NOTES 1.NOTIFY UTILITY PROVIDERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES AND COORDINATE WITH UTILITY PROVIDERS AS NECESSARY DURING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXISTENCE, EXACT LOCATION, AND DEPTH OF ALL UTILITIES. PROTECT ALL UTILITY LINES AND STRUCTURES NOT SHOWN FOR REMOVAL OR MODIFICATION. ANY DAMAGES TO UTILITY ITEMS NOT SHOWN FOR REMOVAL OR MODIFICATION SHALL BE REPAIRED TO THE UTILITY OWNER'S SPECIFICATIONS AT THE CONTRACTOR'S EXPENSE. 2.CONSTRUCTION OF ALL STREET AND UTILITY IMPROVEMENTS SHALL CONFORM TO THE URBAN STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND THE SOILS REPORTS PREPARED BY OTHERS. 3.LENGTH OF UTILITIES SHOWN ON PLANS ARE DIMENSIONED FROM CENTERLINE OF STRUCTURE TO CENTERLINE OF STRUCTURE. 4.ALL TRAFFIC CONTROL SHALL BE PROVIDED IN ACCORDANCE WITH REQUIREMENTS SET FORTH IN THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). WHEN CONSTRUCTION ACTIVITIES OBSTRUCT PORTIONS OF THE ROADWAY, FLAGGERS SHALL BE PROVIDED. FLAGGERS SHALL CONFORM TO THE MUTCD IN APPEARANCE, EQUIPMENT AND ACTIONS. 5.NOTIFY OWNER, ENGINEER AND CITY OF WAUKEE AT LEAST 48 HOURS PRIOR TO BEGINNING WORK. 6.CONSTRUCT MANHOLES AND APPURTENANCES AS WORK PROGRESSES. BACKFILL WITH SUITABLE MATERIAL AND COMPACT TO 95% MAXIMUM DENSITY. 7.IN THE EVENT OF A DISCREPANCY BETWEEN THE QUANTITY ESTIMATES AND THE DETAILED PLANS, THE DETAILED PLANS SHALL GOVERN. 8.ALL FIELD TILES ENCOUNTERED DURING CONSTRUCTION SHALL BE RECONNECTED AND NOTED ACCORDINGLY ON THE AS-BUILT DOCUMENTS. 9.DIMENSIONS, BUILDING LOCATION, UTILITIES AND GRADING OF THIS SITE ARE BASED ON AVAILABLE INFORMATION AT THE TIME OF DESIGN. DEVIATIONS MAY BE NECESSARY IN THE FIELD. ANY SUCH CHANGES OR CONFLICTS BETWEEN THIS PLAN AND FIELD CONDITIONS ARE TO BE REPORTED TO THE ARCHITECT/ENGINEER PRIOR TO STARTING CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LAYOUT VERIFICATION OF ALL SITE IMPROVEMENTS PRIOR TO CONSTRUCTION. 10.CONTRACTOR TO LOAD AND TRANSPORT ALL MATERIALS CONSIDERED TO BE UNDESIRABLE TO BE INCORPORATED INTO THE PROJECT TO AN APPROVED OFF-SITE WASTE SITE. 11.CONTRACTOR TO STRIP AND STOCKPILE TOPSOIL FROM ALL AREAS TO BE CUT OR FILLED. RESPREAD TO MINIMUM 8" DEPTH TO FINISH GRADES. 12.ALL PROPOSED CONTOURS AND SPOT ELEVATIONS SHOWN ARE FINISHED GRADES AND/OR TOP OF PAVING SLAB (GUTTER), UNLESS OTHERWISE NOTED. 13.THE CONTRACTOR IS RESPONSIBLE FOR CLEANING DIRT AND DEBRIS FROM NEIGHBORING STREETS, DRIVEWAYS, AND SIDEWALKS CAUSED BY CONSTRUCTION ACTIVITIES AT THE END OF EACH WORKING DAY AND PRIOR TO A RAIN EVENT.. 14.THE ADJUSTMENT OF ANY EXISTING UTILITY APPURTENANCES TO FINAL GRADE IS CONSIDERED INCIDENTAL TO THE SITE WORK. 15.THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING EROSION CONTROL MEASURES AS NECESSARY. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR MAINTAINING ANY EXISTING EROSION CONTROL MEASURES ON SITE AT THE TIME OF CONSTRUCTION. GRADING AND SOIL EROSION CONTROL CODE REQUIREMENTS SHALL BE MET BY CONTRACTOR. A COSESCO PERMIT IS REQUIRED FOR THIS PROJECT. 16.CONTRACTOR TO COORDINATE NATURAL GAS, ELECTRICAL, TELEPHONE AND ANY OTHER FRANCHISE UTILITY SERVICES WITH UTILITY SERVICE PROVIDER, DALLAS COUNTY, AND THE OWNER PRIOR TO CONSTRUCTION. 17.CONTRACTOR TO VERIFY ALL UTILITY CROSSINGS AND MAINTAIN MINIMUM 18" VERTICAL AND HORIZONTAL CLEARANCE BETWEEN UTILITIES. CONTRACTOR TO COORDINATE UTILITY ROUTING TO BUILDING AND VERIFY CONNECTION LOCATIONS AND INVERTS PRIOR TO CONSTRUCTION. 18.ALL NEW HOMES CONSTRUCTED REQUIRE AND AVAILABLE FIRE FLOW IN ACCORDANCE WITH TABLE B105.1 IN IFC AS ADOPTED BY THE CITY OF WAUKEE AND MAY BE REQUIRED TO BE PROVIDED WITH AND AUTOMATIC FIRE SPRINKLER SYSTEM. CONSULT WITH WAUKEE FIRE DEPARTMENT PRIOR TO SUBMITTING A BUILDING PERMIT. PROPERTY DESCRIPTION LOT 3, TANGLEWOODS ACRES, AN OFFICIAL PLAT, EXCEPT PARCEL 19-21 AS FILED IN BOOK 2019, PAGE 3583 OF THE DALLAS COUNTY RECORDER'S OFFICE ALL BEING IN THE CITY OF WAUKEE, DALLAS COUNTY, IOWA. DATE OF SURVEY 9-1-2020 ZONING R-1 SINGLE FAMILY RESIDENTIAL AND PD-1 PLANED DEVELOPMENT OVERLAY AREA SUMMARY 17.76 AC. BULK REGULATIONS AND SETBACKS FRONT YARD SETBACK = 50' MIN. SIDE YARD SETBACK = 25' MIN. (12.5' EACH SIDE) REAR YARD SETBACK = 35' MIN. LOT SIZE = 30,000SF MIN. LOT WIDTH = 100' MIN. LOT DEPTH = 200' MIN. NOTES 1.PRIOR TO THE START OF ANY CONSTRUCTION ACTIVITIES, A PRECONSTRUCTION MEETING WITH THE CITY IS REQUIRED. 2.WATER MAIN AND SANITARY SEWER WILL BE PUBLIC UTILITIES. CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL CONFORM TO THE CURRENT EDITIONS OF THE WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND THE STATEWIDE URBAN DESIGN AND SPECIFICATIONS. 3.OUTLOT "X" AND OUTLOT "Z" TO BE OWNED AND MAINTAINED BY THE HOME OWNERS ASSOCIATION 4.OUTLOTS A, B AND C SHALL ADJOIN LOTS 6, 5 AND 4 AND BE SOLD AS PART OF THE ADJOINING LOTS. 5.OUTLOT Y AND ANY ASSOCIATED STRUCTURES SHALL BE JOINTLY OWNED AND MAINTAINED BY THE OWNERS OF LOT 6 AND 7. 6.TIMBER CREEK LANE SHALL BE A PRIVATE STREET AND DESIGNED TO PUBLIC STREET STANDARDS. 7.STREET LIGHTS SHALL BE PROVIDED AND BE PRIVATELY OWNED AND MAINTAINED BY THE HOME OWNERS ASSOCIATION. 8.STORM SEWER AND THE PRIVATE STREET WILL BE OWNED AND MAINTAINED BY THE HOME OWNERS ASSOCIATION. 9.SIDEWALK ALONG ASHWORTH RD SHALL BE DEFERED UNTIL THE IMPROVEMENTS TO ASHWORTH RD BY OTHERS. 10.OUTLOT X AND OUTLOT Z SHALL BE PRIVATE STORM SEWER EASEMENTS. 11.SIDEWALK TO TERMINATE AT NORTH EDGE OF FUTURE DRIVEWAY OF LOT 9 DUE TO CONSTRUCTIBILITY CONSTRAINTS ALONG THE EASTERN EDGE TO TIMBER CREEK LANE. PEDESTRIAN ACCESS TO ASHWORTH ROAD IS PROVIDED THROUGHOUT THE DEVELOPMENT.BYDATEREVISIONMARKScale:Technician:T-R-S:SNYDER & ASSOCIATES, INC. |Checked By:Engineer:Date:1" =Project No:SheetProject No: Sheet 2727 S.W. SNYDER BLVDANKENY, IOWA 50023515-964-2020 | www.snyder-associates.comEDCJWMKMM02-15-21 120.0259.01C200120.0259.01 C200TIMBER CREEK PLAT 1PRELIMINARY PLAT - PROJECT INFORMATIONWAUKEE, IAREVISED AS PER CITY COMMENTSREVISED AS PER CITY COMMENTSREVISED AS PER CITY COMMENTSREVISED AS PER CITY COMMENTS3-2-213-16-213-30-214-6-21JWMJWMJWMJWM1234TTN-RRW-SSV:\Projects\2020\120.0259.01\CADD\1200259_PPT.dwg JEREMY W MCCORMICK, PRELIMINARY PLAT - PROJECT INFORMATION, 2021/04/06, 1:10 PM, ANSI FULL BLEED D (34.00 X 22.00 INCHES)UTILITY QUALITY SERVICE LEVELS QUALITY LEVELS OF UTILITIES ARE SHOWN IN THE PARENTHESES WITH THE UTILITY TYPE AND WHEN APPLICABLE, SIZE. THE QUALITY LEVELS ARE BASED ON THE CI / ASCE 38-02 STANDARD. QUALITY LEVEL (D) INFORMATION IS DERIVED FROM EXISTING UTILITY RECORDS OR ORAL RECOLLECTIONS. QUALITY LEVEL (C) INFORMATION IS OBTAINED BY SURVEYING AND PLOTTING VISIBLE ABOVE-GROUND UTILITY FEATURES AND USING PROFESSIONAL JUDGMENT IN CORRELATING THIS INFORMATION WITH QUALITY D INFORMATION. QUALITY LEVEL (B) INFORMATION IS OBTAINED THROUGH THE APPLICATION OF APPROPRIATE SURFACE GEOPHYSICAL METHODS TO DETERMINE THE EXISTENCE AND APPROXIMATE HORIZONTAL POSITION OF SUBSURFACE UTILITIES. QUALITY LEVEL (A) IS HORIZONTAL AND VERTICAL POSITION OF UNDERGROUND UTILITIES OBTAINED BY ACTUAL EXPOSURE OR VERIFICATION OF PREVIOUSLY EXPOSED SUBSURFACE UTILITIES, AS WELL AS THE TYPE, SIZE, CONDITION, MATERIAL, AND OTHER CHARACTERISTICS. UTILITY WARNING THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR RECORDS OBTAINED. THE SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES OR SUBSURFACE FEATURES SHOWN COMPRISE ALL SUCH ITEMS IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UTILITIES OR SUBSURFACE FEATURES SHOWN ARE IN THE EXACT LOCATION INDICATED EXCEPT WHERE NOTED AS QUALITY LEVEL A. FEATURES EXISTING PROPOSED Spot Elevation Contour Elevation Fence (Barbed, Field, Hog) Fence (Chain Link) Fence (Wood) Fence (Silt) Tree Line Tree Stump Deciduous Tree \\ Shrub Coniferous Tree \\ Shrub Communication Overhead Communication Fiber Optic Underground Electric Overhead Electric Gas Main with Size High Pressure Gas Main with Size Water Main with Size Sanitary Sewer with Size Duct Bank Test Hole Location for SUE w/ID (*) Denotes the survey quality service level for utilities Sanitary Manhole Storm Sewer with Size Storm Manhole Single Storm Sewer Intake Double Storm Sewer Intake Fire Hydrant Fire Hydrant on Building Water Main Valve Water Service Valve Well Utility Pole Guy Anchor Utility Pole with Light Utility Pole with Transformer Street Light Yard Light Electric Box Electric Transformer Traffic Sign Communication Pedestal Communication Manhole Communication Handhole Fiber Optic Manhole Fiber Optic Handhole Gas Valve Gas Manhole Gas Apparatus Fence Post or Guard Post Underground Storage Tank Above Ground Storage Tank Sign Satellite Dish Mailbox Sprinkler Head Irrigation Control Valve LEGEND ○ 1 2 2 5 X 1225.25 ● X 1 2 2 5 1225.25 FEATURES FOUND SET Section Corner 1/2" Rebar, Cap # 11579 (Unless Otherwise Noted) ROW Marker ROW Rail Control Point Bench Mark Platted Distance P Measured Bearing & Distance M Recorded As R Deed Distance D Calculated Distance C Minimum Protection Elevation MPE Centerline Section Line 1/4 Section Line 1/4 1/4 Section Line Easement Line UTILITY CONTACT INFORMATION UTILITY CONTACT FOR MAPPING INFORMATION SHOWN AS RECEIVED FROM THE IOWA ONE CALL DESIGN REQUEST SYSTEM, TICKET NUMBER 552006175. G1-GAS MAIN CITY OF WAUKEE S-SANITARY SEWER TIM ROYER ST-STORM SEWER 515-987-7920 troyer@waukee.org FO1-FIBER OPTIC CENTURY LINK Tom Sturmer 303-453-9927 Thomas.sturmer@centurylink.com FO2-FIBER OPTIC MI-FIBER Jack Jones 515-897-9192 jack@grm.net OE1-OVERHEAD ELECTRIC MID AMERICAN ENERGY UE1-UNDERGROUND ELECTRIC JAMIE NEER 515-252-6972 MECDSMDESIGNLOCATES@MIDAMERICAN.COM W1-WATER MAIN XENIA RURAL WATER Laird Van Dee 515-676-2117 lvandee@xeniawater.org NO RESPONSE MEDIACOM COMMUNICATIONS CORP Paul May 515-246-2252 pmay@mediacomcc.com CONTROL POINTS IOWA SOUTH STATE PLANE COORDINATE SYSTEM NAD83(2011)(EPOCH 2010.00) IARTN DERIVED - US SURVEY FEET CP1 N=574727.03 E=1537483.90 Z=921.95 1/2" REBAR WITH RED PLASTIC CAP ON SOUTH SIDE OF ASHWORTH ROAD, +/-25' EAST OF DRIVE TO HOUSE #31495 AT EDGE OF GRAVEL. (AS SHOWN ON SURVEY) EL=921.95 CP2 N=575276.25 E=1537045.36 Z=928.29 1/2" REBAR WITH RED PLASTIC CAP, +/-20' WEST OF FARM HYDRANT, +/-20' EAST OF WEST TREE LINE. (AS SHOWN ON SURVEY) EL=928.29 CP3 N=575423.59 E=1537496.82 Z=947.25 1/2" REBAR WITH RED PLASTIC CAP, +/-10' EAST OF SOUTHEAST FENCE CORNER TO PEN, +/-30' WEST OF EAST TREE LINE. (AS SHOWN ON SURVEY) EL=947.25 CP4 N=575826.20 E=1537082.28 Z=940.28 MAG NAIL AT NORTHEAST CORNER ASPHALT DRIVE, +/-1' SOUTH OF GRAVEL, +/-30' SOUTHWEST OF BUILDING CORNER. (AS SHOWN ON SURVEY) EL=940.28 CP5 N=576023.16 E=1537495.95 Z=963.19 1/2" REBAR, +/-15' SOUTHEAST OF NORTHEAST FENCE CORNER TO PEN, NORTHEAST CORNER OF SITE. (AS SHOWN ON SURVEY) EL=963.19 VARIES VARIES 2.0%2.0% 1.5'1.5' 50' INGRESS/EGRESS EASEMENT 26.0' B/B 6.5'6.5' PRIVATE DRIVE (TIMBER CREEK LANE) TYPICAL SECTION 6.0'6.0' 4.0%4.0% 12" SUBGRADE PREPED IN TWO 6" LIFTS 7" PCCPROFILE GRADE TS @ CL A.POLLUTION PREVENTION AND EROSION PROTECTION 1.CODE COMPLIANCE: THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL POTENTIAL POLLUTION AND SOIL EROSION CONTROL REQUIREMENTS OF THE IOWA CODE, THE IOWA DEPARTMENT OF NATURAL RESOURCES (IDNR) NPDES PERMIT, THE U.S. CLEAN WATER ACT AND ANY LOCAL ORDINANCES. THE CONTRACTOR SHALL TAKE ALL NECESSARY STEPS TO PROTECT AGAINST EROSION AND POLLUTION FROM THIS PROJECT SITE AND ALL OFF-SITE BORROW OR DEPOSIT AREAS DURING PERFORMANCE OR AS A RESULT OF PERFORMANCE. 2.DAMAGE CLAIMS: THE CONTRACTOR WILL HOLD THE OWNER AND ARCHITECT / ENGINEER HARMLESS FROM ANY AND ALL CLAIMS OF ANY TYPE WHATSOEVER RESULTING FROM DAMAGES TO ADJOINING PUBLIC OR PRIVATE PROPERTY, INCLUDING REASONABLE ATTORNEY FEES INCURRED TO OWNER. FURTHER, IF THE CONTRACTOR FAILS TO TAKE NECESSARY STEPS TO PROMPTLY REMOVE EARTH SEDIMENTATION OR DEBRIS WHICH COMES ONTO ADJOINING PUBLIC OR PRIVATE PROPERTY, THE OWNER MAY, BUT NEED NOT, REMOVE SUCH ITEMS AND DEDUCT THE COST THEREOF FROM AMOUNTS DUE TO THE CONTRACTOR. B.STORM WATER DISCHARGE PERMIT 1.THIS PROJECT REQUIRES COVERAGE UNDER THE NPDES GENERAL PERMIT NO. 2 FOR STORM WATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITIES FROM THE IDNR, AS REQUIRED BY THE ENVIRONMENTAL PROTECTION AGENCY (EPA). THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS ARE RESPONSIBLE FOR COMPLIANCE WITH AND FULFILLMENT OF ALL REQUIREMENTS OF THE NPDES GENERAL PERMIT NO. 2 AS SPECIFIED IN THE CONTRACT DOCUMENTS. 2.ALL DOCUMENTS RELATED TO THE STORM WATER DISCHARGE PERMIT, INCLUDING, BUT NOT LIMITED TO, THE NOTICE OF INTENT, PROOF OF PUBLICATIONS, DISCHARGE AUTHORIZATION LETTER, CURRENT SWPPP, SITE INSPECTION LOG, AND OTHER ITEMS, SHALL BE KEPT ON SITE AT ALL TIMES AND MUST BE PRESENTED TO ANY JURISDICTIONAL AGENCIES UPON REQUEST. FAILURE TO COMPLY WITH THE NPDES PERMIT REQUIREMENTS IS A VIOLATION OF THE CLEAN WATER ACT AND THE CODE OF IOWA. 3.A "NOTICE OF DISCONTINUATION" MUST BE FILED WITH THE IDNR UPON FINAL STABILIZATION OF THE DISTURBED SITE AND REMOVAL OF ALL TEMPORARY EROSION CONTROL MEASURES. ALL PLANS, INSPECTION REPORTS, AND OTHER DOCUMENTS MUST BE RETAINED FOR A PERIOD OF THREE YEARS AFTER PROJECT COMPLETION. THE CONTRACTOR SHALL RETAIN A RECORD COPY AND PROVIDE THE ORIGINAL DOCUMENTS TO THE OWNER UPON PROJECT ACCEPTANCE AND/OR SUBMITTAL OF THE NOTICE OF DISCONTINUATION. C.POLLUTION PREVENTION PLAN 1.THE STORM WATER POLLUTION PREVENTION PLAN (SWPPP) IS A SEPARATE DOCUMENT IN ADDITION TO THESE PLAN DRAWINGS. THE CONTRACTOR SHOULD REFER TO THE SWPPP FOR ADDITIONAL REQUIREMENTS AND MODIFICATIONS TO THE POLLUTION PREVENTION PLAN MADE DURING CONSTRUCTION. 2.THE SWPPP ILLUSTRATES GENERAL MEASURES AND BEST MANAGEMENT PRACTICES (BMP) FOR COMPLIANCE WITH THE PROJECT'S NPDES PERMIT COVERAGE. ALL BMP'S AND EROSION CONTROL MEASURES REQUIRED AS A RESULT OF CONSTRUCTION ACTIVITIES ARE THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY, NOTE AND IMPLEMENT. ADDITIONAL BMP'S FROM THOSE SHOWN ON THE PLAN MAY BE REQUIRED. 3.THE SWPPP AND SITE MAP SHOULD BE EXPEDITIOUSLY REVISED TO REFLECT CONSTRUCTION PROGRESS AND CHANGES AT THE PROJECT SITE. 4.THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL REQUIREMENTS OF THE GENERAL PERMIT AND SWPPP, INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING BMP'S UNLESS INFEASIBLE OR NOT APPLICABLE: a.UTILIZE OUTLET STRUCTURES THAT WITHDRAW WATER FROM THE SURFACE WHEN DISCHARGING FROM BASINS, PROVIDE AND MAINTAIN NATURAL BUFFERS AROUND SURFACE WATERS, DIRECT STORM WATER TO VEGETATED AREAS TO INCREASE SEDIMENT REMOVAL AND MAXIMIZE STORM WATER INFILTRATION, AND MINIMIZE SOIL COMPACTION. b.INSTALL PERIMETER AND FINAL SEDIMENT CONTROL MEASURES SUCH AS SILT BARRIERS, DITCH CHECKS, DIVERSION BERMS, OR SEDIMENTATION BASINS DOWNSTREAM OF SOIL DISTURBING ACTIVITIES PRIOR TO SITE CLEARING AND GRADING OPERATIONS. c.PRESERVE EXISTING VEGETATION IN AREAS NOT NEEDED FOR CONSTRUCTION AND LIMIT TO A MINIMUM THE TOTAL AREA DISTURBED BY CONSTRUCTION OPERATIONS AT ANY TIME. d.MAINTAIN ALL TEMPORARY AND PERMANENT EROSION CONTROL MEASURES IN WORKING ORDER, INCLUDING CLEANING, REPAIRING, REPLACEMENT, AND SEDIMENT REMOVAL THROUGHOUT THE PERMIT PERIOD. CLEAN OR REPLACE SILT CONTROL DEVICES WHEN THE MEASURES HAVE LOST 50% OF THEIR ORIGINAL CAPACITY. e.INSPECT THE PROJECT AREA AND CONTROL DEVICES (BY QUALIFIED PERSONNEL ASSIGNED BY THE CONTRACTOR) EVERY SEVEN CALENDAR DAYS. RECORD THE FINDINGS OF THESE INSPECTIONS AND ANY RESULTING ACTIONS IN THE SWPPP WITH A COPY SUBMITTED WEEKLY TO THE OWNER OR ENGINEER DURING CONSTRUCTION. REVISE THE SWPPP AND IMPLEMENT ANY RECOMMENDED MEASURES WITHIN 7 DAYS. f.PREVENT ACCUMULATION OF EARTH AND DEBRIS FROM CONSTRUCTION ACTIVITIES ON ADJOINING PUBLIC OR PRIVATE PROPERTIES, INCLUDING STREETS, DRIVEWAYS, SIDEWALKS, DRAINAGEWAYS, OR UNDERGROUND SEWERS. REMOVE ANY ACCUMULATION OF EARTH OR DEBRIS IMMEDIATELY AND TAKE REMEDIAL ACTIONS FOR FUTURE PREVENTION. g.INSTALL NECESSARY CONTROL MEASURES SUCH AS SILT BARRIERS, EROSION CONTROL MATS, MULCH, DITCH CHECKS OR RIPRAP AS SOON AS AREAS REACH THEIR FINAL GRADES AND AS CONSTRUCTION OPERATIONS PROGRESS TO ENSURE CONTINUOUS RUNOFF CONTROL. PROVIDE INLET AND OUTLET CONTROL MEASURES AS SOON AS STORM SEWERS ARE INSTALLED. h.RESPREAD A MINIMUM OF 8 INCHES OF TOPSOIL (INCLUDING TOPSOIL FOUND IN SOD) ON ALL DISTURBED AREAS, EXCEPT WHERE PAVEMENT, BUILDINGS OR OTHER IMPROVEMENTS ARE LOCATED. i.STABILIZE UNDEVELOPED, DISTURBED AREAS WITH MULCH, TEMPORARY SEED MIX, PERMANENT SEED MIX, SOD, OR PAVEMENT IMMEDIATELY AS SOON AS POSSIBLE UPON COMPLETION OR DELAY OF GRADING OPERATIONS. INITIATE STABILIZATION MEASURES IMMEDIATELY AFTER CONSTRUCTION ACTIVITY IS FINALLY COMPLETED OR TEMPORARILY CEASED ON ANY PORTION OF THE SITE AND WHICH WILL NOT RESUME FOR A PERIOD EXCEEDING 14 CALENDAR DAYS. j.COORDINATE LOCATIONS OF STAGING AREAS WITH THE OWNER AND RECORD IN THE SWPPP. UNLESS NOTED OTHERWISE, STAGING AREAS SHOULD CONTAIN THE FOLLOWING: JOB TRAILERS, FUELING / VEHICLE MAINTENANCE AREA, TEMPORARY SANITARY FACILITIES, MATERIALS STORAGE, AND CONCRETE WASHOUT FACILITY. CONTROL RUNOFF FROM STAGING AREAS WITH DIVERSION BERMS AND/OR SILT BARRIERS AND DIRECT TO A SEDIMENT BASIN OR OTHER CONTROL DEVICE WHERE POSSIBLE. CONCRETE WASHOUT MUST BE CONTAINED ONSITE. k.REMOVE ALL TEMPORARY EROSION CONTROL MEASURES AND SITE WASTE PRIOR TO FILING OF THE "NOTICE OF DISCONTINUATION". 5' SIDEWALK 1.0' 5' SIDEWALK 1.0' 6.5'6.5' 1 2 3 4 515" STF.L.=918.32 15" CMP WF.L.=917.34 15" CMP ERim=922.35Inv.=908.44 12" PVC EInv.=908.35 12" PVC WF.L.=926.98 15" CMP E15" STF.L.=931.98 15" CMP E15" STF.L.=932.74 15" CMP WF.L.=928.46 15" CMP WASHWORTH ROADF.L.=933.28 6" CPP NE6" STF.L.=938.20 6" CPP NE6" STF.L.=938.41 15" CMP NE15" STF.L.=938.68 15" CMP SWRim=911.21Inv.=894.06 36"DIP NWInv.=894.06 36"DIP SEInv.=895.71 12" DIP E104,169 SF 2.39 AC 6 48,329 SF 1.11 AC 5 140,699 SF 3.23 AC 7 43,619 SF 1.00 AC 2 52,876 SF 1.21 AC 8 44,283 SF 1.02 AC 3 52,242 SF 1.20 AC 4 59,714 SF 1.37 AC 9 32,433 SF 0.74 AC 1 13,661 SF0.31 ACSTREET LOT A9,346 SF 0.21 AC OUTLOT Z 13,866 SF 0.32 AC OUTLOT C 16,557 SF 0.38 AC OUTLOT B 11,643 SF 0.27 AC OUTLOT A 93,592 SF 2.15 AC OUTLOT Y 51,348 SF 1.18 AC OUTLOT X 249.15 '124'56'276.52 ' 173. 2 4' 162'255.62 ' 162. 0 4' 80'115.58'98.64'66.13 ' 147. 3 6' 62.96'124.87'48.4 3'294.13'133' 41.8 7'101.10'52 . 9 4 ' 91.47' 61.3 8' 115.5 9' 12.79'232.66'93.67'77' 32' 20' 116.43' 57.40' 218.12'262.41'320.89'148.62'4 1 ' 300.94' 15 9 . 3 2 '43'247.90'318.94'26 . 2 8 '41'323.38'474.31'332.35'37'32' 77' 160.00' 16.45' 243' 203' 144.62' 207.45'227.72'184.24'41.53'46.83'S0°12'07"W 75.54'S83°21'34"W 207.49'N35° 3 5' 3 3" W 6 4 1. 5 1'N58°58'54"W 328.82'N2 2 ° 5 1 ' 2 9 " E 1 6 7 . 6 7 ' N6°13'04"W 109.8 4 ' N1°43'49"W 178.47' N28° 4 5' 4 1" W 1 1 5. 4 2'N82°49'11"E 880.52'S0°12'07"W 778.93' S81°47'51"W 69.65' S0°14'20"W 464.02' N83°25'31"E 69.69'123.01'60.43' 68.5 7' 256.58' 15.11' 1 0 0 Y R F L O O D P L A I N 5 0 0 Y R F L O O D P L A I N 100 YR FLOOD PLAIN 500 YR FLOOD PLAINBOLEY, DEBORAH FIRST REVOCABLELIVING TRUST BOLEY, DEBORAH TRUSTEEZONING: R-1 SUBURBAN RESIDENTIALFOUR SE A S O N S P R O P E R T I E S , I N C ZONING : R - 1 S U B U R B A N R E S I D E N T I A L CHRISTE N S E N , R I C H A R D K I I R E V O C TR 12/14/ 0 1 5 0 % C H R I S T E N S E N , RICHARD K I I T R U S T E E ZONING: R - 1 S U B U R B A N R E S I D E N T I A L JACOBSON, WILLIAM C& KATHERINE A JTRSZONING: R-1 SUBURBANRESIDENTIALMANNI N G, R O B E R T D J R & TIFFA N Y J T R S ZONI N G: A - 1 CHAYSE HOLDIN GS LLCZONING: A-1KLINKEFUS, BRADZONING: R-1 SUBURBAN RESIDENTIALCITY OF W A U K E E ZONING : R - 1 S I N G L E F A M I L Y R E S I D E N T I A L CIRCLE CINVESTMENTS LLCZONING: R-1SUBURBANRESIDENTIAL36" S a nit ar y S e w er 36" Sanitary Sewer36" Sanitary Se wer 36" S a nit ar y S e w er 40' S a nit ar y S e w er E a s e m e nt Bk.20 1 7, P g. 2 6 6 1 10' P u bli c A c c e s s & Trail E a s e m e nt Bk.2 0 1 7, P g. 2 0 1 4 5 THE NEW PIONEER GUN CLUB ZONING: COMMERCIAL BYDATEREVISIONMARKScale:Technician:T-R-S:SNYDER & ASSOCIATES, INC. |Checked By:Engineer:Date:1" =Project No:SheetProject No: Sheet 2727 S.W. SNYDER BLVDANKENY, IOWA 50023515-964-2020 | www.snyder-associates.comEDCJWMKMM02-15-2150120.0259.01C201120.0259.01 C201TIMBER CREEK PLAT 1PRLIMINARY PLAT - EXISTING SITE SURVEY & DEMOLITION PLANWAUKEE, IAREVISED AS PER CITY COMMENTSREVISED AS PER CITY COMMENTSREVISED AS PER CITY COMMENTSREVISED AS PER CITY COMMENTS3-2-213-16-213-30-214-6-21JWMJWMJWMJWM1234TTN-RRW-SSV:\Projects\2020\120.0259.01\CADD\1200259_PPT.dwg JEREMY W MCCORMICK, PRELIMINARY PLAT- EXISTING SITE SURVEY & DEMOLITION PLAN, 2021/04/06, 1:10 PM, ANSI FULL BLEED D (34.00 X 22.00 INCHES)FEET 0 50 REMOVE EXISTING CULVERT TREE REMOVAL (TYP) X X X X X X X X X X X X X X X X COORDINATE REMOVAL OF EXISTING SEPTIC SYSTEM WITH PROPERTY OWNER REMOVE EXISTING FENCE (TYP) X X X XX XX X X X X X X XXXXXXX X X X X X X X XXXX X X X X X X X REMOVE EXISTING FENCE (TYP) REMOVE EXISTING FENCE (TYP) REMOVE EXISTING DRIVE REMOVE EXISTING DRIVE ABANDON EXISTING ELECTRIC SERVICE ABANDON EXISTING FIBER SERVICE TREE REMOVAL (TYP) X X X X X X X X X X XX X X X X X X TREE REMOVAL (TYP) REMOVE EXISTING CULVERT REMOVE EXISTING CULVERT X X X ABANDON AND REMOVE EXISTING METER PIT REMOVE EXISTING CULVERTABANDON EXISTING ELECTRIC SERVICE REMOVE EXISTING OVERHEAD ELECTRIC SERVICE TREE REMOVAL (TYP) TREE REMOVAL (TYP) NOTES 1.COORDINATE THE ABANDONMENT AND REMOVAL OF ALL EXISTING UTILITY SERVICE LINES PRIOR TO CONSTRUCTION. 2.EXISTING SEPTIC SEWER TO BE ABANDONED AND REMOVED IN COMPLIANCE WITH IDNR AND DALLAS COUNTY ENVIRONMENTAL HEALTH DEPARTMENT REQUIREMENTS. 3.CONTRACTOR TO ABANDON ANY EXISTING WELLS IN COMPLIANCE WITH IDNR AND DALLAS COUNTY ENVIRONMENTAL HEALTH DEPARTMENT REQUIREMENTS. PROTECT EXISTING WOOD FENCE PROTECT EXISTING WOOD FENCE TIMBERC R E E K L A N E ASHWORTH RD 1 2 3 4 515" ST15" ST15" STASHWORTH ROAD6" ST6" ST15" ST8" SAN 8" SA N 8" SAN 8" SA N 4" SAN 4" SAN 6" SAN24" ST 15" ST30" ST8" ST 8" ST8" ST 24" ST 18" ST8"W 8"W 8"W 8"W 50' B. S. L 50' B. S. L 50' B.S.L 50' B.S.L50' B.S.L 50' B.S.L 26.0'B/BR45.0'20.0'40.0'20.0'104,169 SF 2.39 AC 6 48,329 SF 1.11 AC 5 140,699 SF 3.23 AC 7 43,619 SF 1.00 AC 2 52,876 SF 1.21 AC 8 44,283 SF 1.02 AC 3 52,242 SF 1.20 AC 4 59,714 SF 1.37 AC 9 32,433 SF 0.74 AC 1 13,661 SF0.31 ACSTREET LOT A9,346 SF 0.21 AC OUTLOT Z 13,866 SF 0.32 AC OUTLOT C 16,557 SF 0.38 AC OUTLOT B 11,643 SF 0.27 AC OUTLOT A 93,592 SF 2.15 AC OUTLOT Y 51,348 SF 1.18 AC OUTLOT X 249.15 '124'56'276.52 ' 173. 2 4' 162'255.62 ' 162. 0 4' 80'115.58'98.64'66.13 ' 147. 3 6' 62.96'124.87'48.4 3'294.13'133' 41.8 7'101.10'52 . 9 4 ' 91.47' 61.3 8' 115.5 9' 12.79'232.66'93.67'77' 32' 20' 116.43' 57.40' 218.12'262.41'320.89'148.62'4 1 ' 300.94' 15 9 . 3 2 '43'247.90'318.94'26 . 2 8 '41'323.38'474.31'332.35'37'32' 77' 160.00' 16.45' 243' 203' 144.62' 207.45'227.72'184.24'41.53'46.83'S0°12'07"W 75.54'S83°21'34"W 207.49'N35° 3 5' 3 3" W 6 4 1. 5 1'N58°58'54"W 328.82'N2 2 ° 5 1 ' 2 9 " E 1 6 7 . 6 7 ' N6°13'04"W 109.8 4 ' N1°43'49"W 178.47' N28° 4 5' 4 1" W 1 1 5. 4 2'N82°49'11"E 880.52'S0°12'07"W 778.93' S81°47'51"W 69.65' S0°14'20"W 464.02' N83°25'31"E 69.69'123.01'60.43' 68.5 7' 256.58' 15.11' 1 0 0 Y R F L O O D P L A I N 5 0 0 Y R F L O O D P L A I N 100 YR FLOOD PLAIN 500 YR FLOOD PLAIN 60' ROW 18 " S T 1 5 " S T 15" ST15" ST15" ST15" ST15" ST24" ST6" SAN4" SAN 18" ST24" ST4" S T 4" S T 4" S T 18" S T 1 5 " S T (Private) 15' Storm Sewer Easement (Private) 15' Storm Sewer Easement (Privat e) St or m S e w er a n d O v erl a n d Fl o w a g e E a s e m e nt 26' Ingress/Egress Easement FUTURE CITY 16" WATER MAIN ENTRANCE GATE 50' In gr e s s/ E gr e s s Ease m e nt BOLEY, DEBORAH FIRST REVOCABLELIVING TRUST BOLEY, DEBORAH TRUSTEEZONING: R-1 SUBURBAN RESIDENTIALFOUR SE A S O N S P R O P E R T I E S , I N C ZONING : R - 1 S U B U R B A N R E S I D E N T I A L CHRISTE N S E N , R I C H A R D K I I R E V O C TR 12/14/ 0 1 5 0 % C H R I S T E N S E N , RICHARD K I I T R U S T E E ZONING: R - 1 S U B U R B A N R E S I D E N T I A L JACOBSON, WILLIAM C& KATHERINE A JTRSZONING: R-1 SUBURBANRESIDENTIALMANNI N G, R O B E R T D J R & TIFFA N Y J T R S ZONI N G: A - 1 CHAYSE HOLDIN GS LLCZONING: A-1KLINKEFUS, BRADZONING: R-1 SUBURBAN RESIDENTIALCITY OF W A U K E E ZONING : R - 1 S I N G L E F A M I L Y R E S I D E N T I A L CIRCLE CINVESTMENTS LLCZONING: R-1SUBURBANRESIDENTIAL36" S a nit ar y S e w er 36" Sanitary Sewer36" Sanitary Se wer 22' B/B 12' SIDE YARD 12' SIDE YARD 35' REAR YARDRETAINING WALL TO BE DESIGNED BY STRUCTURAL ENGINEER 36" S a nit ar y S e w er 40' S a nit ar y S e w er E a s e m e nt Bk.20 1 7, P g. 2 6 6 1 35' REAR YARD12' SIDE YARD 35' REAR Y A R D 12' SIDE YARD90' EX. ROW 120' FUTURE R O W 1"W 10' P u bli c A c c e s s & Trail E a s e m e nt Bk.2 0 1 7, P g. 2 0 1 4 5 THE NEW PIONEER GUN CLUB ZONING: COMMERCIAL BYDATEREVISIONMARKScale:Technician:T-R-S:SNYDER & ASSOCIATES, INC. |Checked By:Engineer:Date:1" =Project No:SheetProject No: Sheet 2727 S.W. SNYDER BLVDANKENY, IOWA 50023515-964-2020 | www.snyder-associates.comEDCJWMKMM02-15-2150120.0259.01C300120.0259.01 C300TIMBER CREEK PLAT 1PRELIMINARY PLAT - LAYOUT PLANWAUKEE, IAREVISED AS PER CITY COMMENTSREVISED AS PER CITY COMMENTSREVISED AS PER CITY COMMENTSREVISED AS PER CITY COMMENTS3-2-213-16-213-30-214-6-21JWMJWMJWMJWM1234TTN-RRW-SSV:\Projects\2020\120.0259.01\CADD\1200259_PPT.dwg JEREMY W MCCORMICK, PRELIMINARY PLAT - LAYOUT PLAN, 2021/04/06, 1:10 PM, ANSI FULL BLEED D (34.00 X 22.00 INCHES)FEET 0 50 Overland Flowage Easement 10' P.U.E. 10' Gas Easement 10' Gas Easement 10' P.U.E. 40' Sanitary Sewer Easement 10' Gas Easement 10' P.U.E. 20' Water Main Easement 10' Overland Flowage Easement 10' Overland Flowage Easement (Private)15' Overland Flowage and Storm Sewer Easement (Private) Sanitary Sewer Easement (Private) 15' Storm Sewer Easement (Private)15' Storm Sewer Easement 10' P.U.E. 25' LANDSCAPE BUFFER EASEMENT 10' P.U.E. (Private) Storm Sewer Easement (Private) Sanitary Sewer Easement TIMBERC R E E K L A N E ASHWORTH RD 1 2 3 4 515" STF.L.=918.32 15" CMP WF.L.=917.34 15" CMP ERim=922.35Inv.=908.44 12" PVC EInv.=908.35 12" PVC WF.L.=926.98 15" CMP E15" STF.L.=931.98 15" CMP E15" STF.L.=932.74 15" CMP WF.L.=928.46 15" CMP WF.L.=933.28 6" CPP NE6" STF.L.=938.20 6" CPP NE6" STF.L.=938.41 15" CMP NE15" STF.L.=938.68 15" CMP SWRim=911.21Inv.=894.06 36"DIP NWInv.=894.06 36"DIP SEInv.=895.71 12" DIP E8" SAN 8" SA N 8" SAN 8" SA N 4" SAN 4" SAN 6" SAN24" ST 15" ST30" ST8" ST 8" ST8" ST 24" ST 18" ST8"W 8"W 8"W 8"W 50' B. S. L 50' B. S. L 50' B.S.L 50' B.S.L50' B.S.L 50' B.S.L 26.0'B/BR45.0'20.0'40.0'20.0'104,169 SF 2.39 AC 6 48,329 SF 1.11 AC 5 140,699 SF 3.23 AC 7 43,619 SF 1.00 AC 2 52,876 SF 1.21 AC 8 44,283 SF 1.02 AC 3 52,242 SF 1.20 AC 4 59,714 SF 1.37 AC 9 32,433 SF 0.74 AC 1 13,661 SF0.31 ACSTREET LOT A9,346 SF 0.21 AC OUTLOT Z 13,866 SF 0.32 AC OUTLOT C 16,557 SF 0.38 AC OUTLOT B 11,643 SF 0.27 AC OUTLOT A 93,592 SF 2.15 AC OUTLOT Y 51,348 SF 1.18 AC OUTLOT X 1 0 0 Y R F L O O D P L A I N 5 0 0 Y R F L O O D P L A I N 100 YR FLOOD PLAIN 500 YR FLOOD PLAIN 60' ROW 18 " S T 1 5 " S T 15" ST15" ST15" ST15" ST15" ST24" ST6" SAN4" SAN 18" ST24" ST4" S T 4" S T 4" S T 18" S T 1 5 " S T (Private) 15' Storm Sewer Easement (Private) 15' Storm Sewer Easement (Privat e) St or m S e w er a n d O v erl a n d Fl o w a g e E a s e m e nt MPE=928.00 MPE=928.00 MPE=924.00 26' Ingress/Egress Easement FUTURE CITY 16" WATER MAIN ENTRANCE GATE 50' In gr e s s/ E gr e s s Ease m e nt BOLEY, DEBORAH FIRST REVOCABLELIVING TRUST BOLEY, DEBORAH TRUSTEEZONING: R-1 SUBURBAN RESIDENTIALFOUR SE A S O N S P R O P E R T I E S , I N C ZONING : R - 1 S U B U R B A N R E S I D E N T I A L CHRISTE N S E N , R I C H A R D K I I R E V O C TR 12/14/ 0 1 5 0 % C H R I S T E N S E N , RICHARD K I I T R U S T E E ZONING: R - 1 S U B U R B A N R E S I D E N T I A L JACOBSON, WILLIAM C& KATHERINE A JTRSZONING: R-1 SUBURBANRESIDENTIALMANNI N G, R O B E R T D J R & TIFFA N Y J T R S ZONI N G: A - 1 CHAYSE HOLDIN GS LLCZONING: A-1KLINKEFUS, BRADZONING: R-1 SUBURBAN RESIDENTIALCITY OF W A U K E E ZONING : R - 1 S I N G L E F A M I L Y R E S I D E N T I A L CIRCLE CINVESTMENTS LLCZONING: R-1SUBURBANRESIDENTIAL36" S a nit ar y S e w er 36" Sanitary Sewer36" Sanitary Se wer 15 0 ' H Y D R A N T C O V E R A G E 150' HYDRANT COVERAGE150' HYDRANT COVERAGE150' HYDRANT COVERAGE1 5 0 ' H Y D R A N T C O V E R A G E MPE=942.00 MPE=938.00 MPE=937.00 MPE=928.00 MPE=916.00 MPE=916.00 22' B/B 12' SIDE YARD 12' SIDE YARD 35' REAR YARDRETAINING WALL TO BE DESIGNED BY STRUCTURAL ENGINEER 36" S a nit ar y S e w er 40' S a nit ar y S e w er E a s e m e nt Bk.20 1 7, P g. 2 6 6 1 35' REAR YARD12' SIDE YARD 35' REAR Y A R D 12' SIDE YARD90' EX. ROW 120' FUTURE R O W 1"W 10' P u bli c A c c e s s & Trail E a s e m e nt Bk.2 0 1 7, P g. 2 0 1 4 5 THE NEW PIONEER GUN CLUB ZONING: COMMERCIAL BYDATEREVISIONMARKScale:Technician:T-R-S:SNYDER & ASSOCIATES, INC. |Checked By:Engineer:Date:1" =Project No:SheetProject No: Sheet 2727 S.W. SNYDER BLVDANKENY, IOWA 50023515-964-2020 | www.snyder-associates.comEDCJWMKMM02-15-2150120.0259.01C400120.0259.01 C400TIMBER CREEK PLAT 1PRELIMINARY PLAT - UTILITY PLANWAUKEE, IAREVISED AS PER CITY COMMENTSREVISED AS PER CITY COMMENTSREVISED AS PER CITY COMMENTSREVISED AS PER CITY COMMENTS3-2-213-16-213-30-214-6-21JWMJWMJWMJWM1234TTN-RRW-SSV:\Projects\2020\120.0259.01\CADD\1200259_PPT.dwg JEREMY W MCCORMICK, PRELIMINARY PLAT - UTILITY PLAN, 2021/04/06, 1:10 PM, ANSI FULL BLEED D (34.00 X 22.00 INCHES)FEET 0 50 TIMBERC R E E K L A N E ASHWORTH RD 1 2 3 4 515" ST15" ST15" STASHWORTH ROAD6" ST6" ST15" ST939 940 941 941 941 942 943 944 945 9379399 4 0 940941 942 943 939 939 938 937 936 938938 937936 936936936 936 937 9389399409419 3 9 9 3 8 9 3 7 9 3 6 935934933932931930929915920920 923 922930 928 930 931 9409419 4 2 940939 940941942943939938 937 935941 940 93 5 93 0 92 5947947 947 944 92993 8 932 933 934 935 940941942 942942 943 944 945 931 931927 923924925926927928929931930932933934 930931932 933 935 936 937 938 939 940 941 942 943 944 945 946 947 915920922921933934935936937938 939 936937938939940941942943944945946 943944 945 946 947 948 949 950 951 952 953 954 955 956 957 958965 93093193293393493450' B. S. L 50' B. S. L 50' B.S.L 50' B.S.L50' B.S.L 50' B.S.L 26.0'B/BR45.0'20.0'40.0'20.0'104,169 SF 2.39 AC 6 48,329 SF 1.11 AC 5 140,699 SF 3.23 AC 7 43,619 SF 1.00 AC 2 52,876 SF 1.21 AC 8 44,283 SF 1.02 AC 3 52,242 SF 1.20 AC 4 59,714 SF 1.37 AC 9 32,433 SF 0.74 AC 1 13,661 SF0.31 ACSTREET LOT A9,346 SF 0.21 AC OUTLOT Z 13,866 SF 0.32 AC OUTLOT C 16,557 SF 0.38 AC OUTLOT B 11,643 SF 0.27 AC OUTLOT A 93,592 SF 2.15 AC OUTLOT Y 51,348 SF 1.18 AC OUTLOT X 9399359309259259379369349339329319309299289279269259241 0 0 Y R F L O O D P L A I N 5 0 0 Y R F L O O D P L A I N 100 YR FLOOD PLAIN 500 YR FLOOD PLAIN 60' ROW (Private) 15' Storm Sewer Easement (Private) 15' Storm Sewer Easement936935935 9 3 6937938939 926923 923 925926928931(Privat e) St or m S e w er a n d O v erl a n d Fl o w a g e E a s e m e nt 923922 921 923924928 927926927930933 937 950 955 950955960950 945 944 935 938 939935940935 935 936 937 938 MPE=928.00 MPE=928.00 MPE=924.00 26' Ingress/Egress Easement FUTURE CITY 16" WATER MAIN ENTRANCE GATE 50' In gr e s s/ E gr e s s Ease m e nt 2.4% 1.0% 1.0% Overflow 922.20 2.0% HP927.85 3.7% Overflow 934.77 3.0%2.0%2. 0 %2.0%BOLEY, DEBORAH FIRST REVOCABLELIVING TRUST BOLEY, DEBORAH TRUSTEEZONING: R-1 SUBURBAN RESIDENTIALFOUR SE A S O N S P R O P E R T I E S , I N C ZONING : R - 1 S U B U R B A N R E S I D E N T I A L CHRISTE N S E N , R I C H A R D K I I R E V O C TR 12/14/ 0 1 5 0 % C H R I S T E N S E N , RICHARD K I I T R U S T E E ZONING: R - 1 S U B U R B A N R E S I D E N T I A L JACOBSON, WILLIAM C& KATHERINE A JTRSZONING: R-1 SUBURBANRESIDENTIALMANNI N G, R O B E R T D J R & TIFFA N Y J T R S ZONI N G: A - 1 CHAYSE HOLDIN GS LLCZONING: A-1KLINKEFUS, BRADZONING: R-1 SUBURBAN RESIDENTIALCITY OF W A U K E E ZONING : R - 1 S I N G L E F A M I L Y R E S I D E N T I A L CIRCLE CINVESTMENTS LLCZONING: R-1SUBURBANRESIDENTIAL36" S a nit ar y S e w er 36" Sanitary Sewer36" Sanitary Se wer MPE=942.00 MPE=938.00 MPE=937.00 MPE=928.00 MPE=916.00 MPE=916.00 22' B/B 945.00 937. 9 1 937.12936.52940.81 936.11945.00 939.38 9 3 6 . 0 0 936.46 937.08 929.07 940. 8 0 939.77941.89937.12936.09946.06937.13 938.88 931. 1 0 930.1 8 926.68922.74927.9 3 936.02 9 2 6 . 9 3 922.70 942.99 935.90 935.17 936.7 1 936.69 921.36 9 2 9 . 5 3 93 8 . 2 8 9 3 9 . 3 3 93 7 . 1 9 936.49934.38 970.90 957.00 952.50 946.70 918. 0 0 920. 5 0 925. 5 0 925. 5 0 927. 0 0 917.00 918.00 920.00 907.00 918.50 921.00 916.00 907.00 915.50 918.00 920.00 933.00 907.00912.00 911.00 940.29 956.00 964.50 936.0 0 12' SIDE YARD 12' SIDE YARD 35' REAR YARD100YR 939.70 100YR 938.40 100YR 936.41 100YR 9 3 5 . 2 5 100YR 9 3 5 . 1 2 935.7393 0 . 5 7 934.8793 3 . 9 7 937.27936.91934.679 3 1 . 7 7 9 2 9 . 4 2 9 2 7 . 1 3 925. 0 0 929.88RETAINING WALL TO BE DESIGNED BY STRUCTURAL ENGINEER 36" S a nit ar y S e w er 40' S a nit ar y S e w er E a s e m e nt Bk.20 1 7, P g. 2 6 6 1 35' REAR YARD12' SIDE YARD 35' REAR Y A R D 12' SIDE YARD90' EX. ROW 120' FUTURE R O W 93 6 . 3 6 916. 8 3 924. 3 6 945 946 943 942 941 941942943 944945 10' P u bli c A c c e s s & Trail E a s e m e nt Bk.2 0 1 7, P g. 2 0 1 4 5 933.00 929.00 7.2%6.0%3.1%3.5%4.1% 8 . 0%7.0%4.0%2.0%100Y R = 9 2 2. 9 5( C urr e nt) 100Y R = 9 2 2. 0 4( F ut ur e) 100YR=932.88(Current) 100YR=932.34(Future) Normal Pool=929.00 3.0%6.7%1.5% 2.0%97'112'110'84'133'61'55'57'THE NEW PIONEER GUN CLUB ZONING: COMMERCIAL Normal Pool=919.00 ●●●●●●●●●●●●●●●●● ●● ● ● ● ● ●●●●●●●●●●●●●●●●●●●●●●●● ● ● ● ●●●●●●● ● ● ● ● ●● ●●●● ● ● ● ● ● ● ●●●●● ●●●● ● ● ●●●●●● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●● ●●●●● ● ● ● ● ● ● ●●●● ●●●●● ●●●TOPSOIL STOCKPILE STAGING AREA CONSTRUCTION DUMPSTER SEDIMENT BASKET(TYP) SEDIMENT BASKET(TYP) STABILIZED CONSTRUCTION ENTRANCE SILT FENCE (TYP) SILT FENCE (TYP) SILT FENCE (TYP) ULTIMATE DISCHARGE TO SUGAR CREEK 10 TONS CLASS D RIP RAP 10 TONS CLASS D RIP RAP 10 TONS CLASS D RIP RAP 10 TONS CLASS D RIP RAP ● ●●● ● ● ● ● ● ● ● ● ● ●●●●● ● ● ● ● ●●● ● ●●●●●●●●●●●● ● ● ● ●●●●●●●●●●●●●●●● ● ● ●●●●●●●●● ● ●● ●●● ● ● ● ● ●●●●●●●● ● ● ● ● SILT FENCE (TYP) SILT FENCE (TYP) SILT FENCE (TYP)SILT FENCE (TYP) SILT F E N C E (T Y P) SILT FENCE (TYP)BYDATEREVISIONMARKScale:Technician:T-R-S:SNYDER & ASSOCIATES, INC. |Checked By:Engineer:Date:1" =Project No:SheetProject No: Sheet 2727 S.W. SNYDER BLVDANKENY, IOWA 50023515-964-2020 | www.snyder-associates.comEDCJWMKMM02-15-2150120.0259.01C500120.0259.01 C500TIMBER CREEK PLAT 1PRELIMINARY PLAT - GRADING AND EROSION CONTROL PLANWAUKEE, IAREVISED AS PER CITY COMMENTSREVISED AS PER CITY COMMENTSREVISED AS PER CITY COMMENTSREVISED AS PER CITY COMMENTS3-2-213-16-213-30-214-6-21JWMJWMJWMJWM1234TTN-RRW-SSV:\Projects\2020\120.0259.01\CADD\1200259_PPT.dwg JEREMY W MCCORMICK, PRELIMINARY PLAT - GRADING EROSION CONTROL PLAN, 2021/04/06, 1:11 PM, ANSI FULL BLEED D (34.00 X 22.00 INCHES)FEET 0 50 NOTES 1.FEMA FLOOD PLAIN PANEL 19049C0335F EFFECTIVE DATE 12/07/2018 2.OUTLOT Z SHALL BE A DETENTION EASEMENT 3.SOIL QUALITY RESTORATION WILL BE REQUIRED FOR THE REAR YARDS OF LOTS 3-5 TO CONSIST OF DEEP TINE AERATION AND A MINIMUM OF 8" TOP SOIL RESPREAD. 10' Overland Flowage Easement 10' Overland Flowage Easement QUANTITIES SILT FENCE = 4867 LF SEDIMENT BASKET = 10 EA SEEDING AND MULCHING (TYPE 4 URBAN TEMPORARY SEED MIX) = 12.0 AC DISTURBED AREA = 12.0 AC CLASS D RIP RAP = 40 TONS ASHWORTH RD 132,433 SF 0.74 AC 1 13,661 SF0.31 ACSTREET LOT A9,346 SF 0.21 AC OUTLOT Z 115.58'98.64'66.13 ' 62.96'124.87'48.4 3' S0°12'07"W 75.54'S83°21'34"W 207.49'N83°25'31"E 69.69'123.01'60.43' 68.5 7' 256.58' 15.11'OVERSTORYTREE (TYP)UNDERSTORYTREE (TYP)EVERGREENTREE (TYP)CONTRACTOR TO PROVIDE ONE-THIRDOF REQUIRED PLANT MATERIAL FOR A25' WIDE BUFFER.BYDATEREVISIONMARKScale:Technician:T-R-S:SNYDER & ASSOCIATES, INC. |Checked By:Engineer:Date:1" =Project No:SheetProject No: Sheet 2727 S.W. SNYDER BLVDANKENY, IOWA 50023515-964-2020 | www.snyder-associates.comEDCJWMKMM02-15-2120120.0259.01C600120.0259.01 C600TIMBER CREEK PLAT 1PRELIMINARY PLAT - LANDSCAPE BUFFER PLANWAUKEE, IAREVISED AS PER CITY COMMENTSREVISED AS PER CITY COMMENTSREVISED AS PER CITY COMMENTSREVISED AS PER CITY COMMENTS3-2-213-16-213-30-214-6-21JWMJWMJWMJWM1234TTN-RRW-SSV:\Projects\2020\120.0259.01\CADD\1200259_PPT.dwg JEREMY W MCCORMICK, PRELIMINARY PLAT - LANDSCAPE BUFFER PLAN, 2021/04/06, 1:11 PM, ANSI FULL BLEED D (34.00 X 22.00 INCHES)FEET 0 20 25' LANDSCAPE BUFFER EASEMENT