Loading...
HomeMy WebLinkAbout2021-05-03-J01T Underground Electric Service Extension Agr_Ashworth RdAGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: May 3, 2021 AGENDA ITEM:Consideration of approval of a resolution approving proposal from MidAmerican Energy for Refundable Advance for Construction Underground Electric Service Extension for Speculative Use in the amount of $16,164.94 [SE Ashworth Road] FORMAT:Resolution SYNOPSIS INCLUDING PRO & CON: Mid American Energy proposes to extend its electric lines underground to new sources needed for streetlights cabinets on Ashworth Road. These electrical services are necessary for the SE Ashworth Rd Corridor Improvements project. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS:$16,164.94. This amount will be refunded over a 6 year period at 50% of the annual metered electric serve bill. COMMISSION/BOARD/COMMITTEE COMMENT: STAFF REVIEW AND COMMENT: RECOMMENDATION: Approve the resolution. ATTACHMENTS: I. Resolution II. MidAmerican Energy Proposal PREPARED BY: Beth Richardson REVIEWED BY: Rudy Koester RK PUBLIC NOTICE INFORMATION – NAME OF PUBLICATION: DATE OF PUBLICATION: J1T THE CITY OF WAUKEE, IOWA RESOLUTION 2021- APPROVING MIDAMERICAN ENERGY COMPANY REFUNDABLE ADVANCE FOR CONSTRUCTION, UNDERGROUND ELECTRIC SERVICE EXTENSION PROPOSAL OF SPECULATIVE USE [ASHWORTH ROAD] IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, MidAmerican Energy Company proposes to extend underground electric service lines underground to new sources needed for streetlight controller cabinets on SE Ashworth Road; AND, WHEREAS, City staff recommend approval of the agreement; NOW THEREFORE BE IT RESOLVED by the City of Waukee City Council in session this 3rd day of May, 2021, that the MidAmerican Energy Company Refundable Advance for Construction, Underground Electric Service Extension Proposal of Speculative Use [SE Ashworth Road], attached hereto as Exhibit A and made part of this resolution, is hereby approved. ____________________________ Courtney Clarke, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN Anna Bergman Pierce R. Charles Bottenberg Chris Crone Larry R. Lyon Ben Sinclair April 27th, 2021 City of Waukee 805 University Ave. Waukee, IA 50263 rkoester@waukee.org Reference: Underground electric extension to new source needed for streetlights and traffic cabinets on Ashworth Rd. in Waukee, IA. WMIS: 2871094 Dear Mr. Koester: We are pleased to submit the Refundable Advance for Construction Underground Electric Service Extension Proposal for Speculative Use for the above project. This proposal is valid for 90 days and if MidAmerican Energy construction has not commenced within 12 months it may be voided. Please sign and return the proposal as soon as you are ready to commit to the work. You may withhold payment until MidAmerican Energy Company completes the work in this proposal. In the meantime, please keep me informed of your schedule. After we have received your signed proposal, we will sign and return a copy of the proposal for your records. If you have any questions, please call me at (515) 252-6742. Sincerely, MidAmerican Energy Company Scot Enger Customer Project Coordinator REFUNDABLE ADVANCE FOR CONSTRUCTION UNDERGROUND ELECTRIC DISTRIBUTION EXTENSION PROPOSAL FOR SPECULATIVE USE – WMIS: 2871094 MidAmerican Energy Company, an Iowa corporation and the City of Waukee ("Applicant"), agree as follows: 1. MidAmerican Energy Company will extend its electric lines underground to serve City owned streetlights and traffic cabinets on Ashworth Rd. as shown on the attached drawings. 2. MidAmerican Energy Company will furnish the necessary labor and materials required to fulfill its undertaking, as specified above, and will commence such work as soon as reasonable and practicable after the execution of this Proposal and receipt of Applicant's cash deposit indicated below, and will prosecute such work to completion with reasonable diligence. 3. In consideration of the signed proposal and agreement to pay in the amount of $16,164.94 which is a refundable Advance for Construction, MidAmerican Energy Company agrees to construct necessary electric facilities as set forth above. Payment may be withheld until the proposed work is completed. 4. The Advance for Construction shall be subject to refund by MidAmerican Energy Company to Applicant based upon the following terms and conditions: a. Advances shall not accrue interest and shall be subject to refund from the date of original advance payment. This will span a six- year period at the rate of fifty percent (50%) of the annual metered electric service bill of the above Applicant. b. If additional customers are connected to the above described line extension, the above Applicant shall receive refunds equal to three times estimated base revenue for each additional new customer to the extent the base revenue exceeds the additional distribution construction costs incurred by MidAmerican Energy Company. Base revenue shall be estimated annual kilowatt hours based on similarly situated customers, less the cost of fuel. c. Refunds shall be made on the anniversary date of the original advance payment or sooner at the option of MidAmerican Energy Company. d. Revenue for un-metered private lighting shall not be included in any refund. e. No refunds shall be made for revenue received after six (6) years from the date of the original advance payment. f. Never shall the total of refunds exceed the refundable portion of the payment stated above. g. No refunds shall be made for customers served from a further extension of the above described electric line extension. 5. Except as may hereinafter be provided, MidAmerican Energy Company shall: a. Not tamp the backfill. Applicant agrees to indemnify and hold MidAmerican Energy Company harmless from any and all damages that may result from the non-tamping of backfill operations conducted by MidAmerican Energy Company. In case any action is brought against MidAmerican Energy Company, or any of its agents or employees, relative to such backfill operations, the Applicant shall assume full responsibility for the defense thereof. Upon failure to do so on proper notice, MidAmerican Energy Company reserves the right to defend such action and charge all costs to the Applicant provided, however, that nothing herein shall be construed as an assumption of liability by the Applicant for damages and claims attributable to MidAmerican Energy Company negligence. 6. Applicant shall provide, without cost to MidAmerican Energy Company, such easements as are necessary and incidental to such installation and use of MidAmerican Energy's facilities on private property within the area served. If a 3rd party easement is required any cost associated in obtaining the easement will be paid by the applicant. 7. Applicant shall be responsible for complying with all aspects of compliance as required by any local, state, or federal permit or plan associated with storm water pollution prevention or erosion control. It is specifically understood and agreed that MidAmerican Energy Company is providing the service requested by the Applicant solely for the Applicant. MidAmerican Energy Company will not become or agree to become a co-permittee or operator for the purpose of applicants’ compliance with any local, state or federal permit or plan associated with storm water pollution prevention or erosion control. 8. Applicant shall be responsible for locating and marking all privately owned systems such as water services, culverts, irrigation systems, drainpipes, septic lines, and underground wiring before MidAmerican Energy Company's construction. 9. It is specifically understood and agreed that any distribution systems, or other facilities constructed or installed by MidAmerican Energy Company under terms of this Proposal shall remain the sole property of MidAmerican Energy Company and MidAmerican Energy Company shall determine, as its own judgment indicates, the manner and method of utilization thereof and to extend the same or connect other facilities there to and serve other customers there from as it shall see fit, subject only to such obligations as MidAmerican Energy Company shall have assumed in this Proposal; and no other person shall have any right, title, interest or claim, in or to the said distribution system or other facilities by virtue of any provision of this Proposal. 10. Applicant shall furnish, install, own and maintain all 4-inch ducts as shown on attached prints. All ducts shall be black w/red stripe or grey in color, PVC type schedule 40 or schedule 40 HDPE coil-able. Applicant shall install ducts a minimum of forty-two (42) inches and a maximum of forty-eight (48) inches below finish grade with capped and staked ends and equipped with pull wires. MidAmerican Energy Company will provide marker balls for the duct ends. These are available at MidAmerican Energy Company’s storeroom. Applicant is responsible for correct placement and depth of conduit. Note: No more than ten (10) conduits allowed within the secondary compartment of the transformer pad. Proposed this 27th day of April, 2021. MIDAMERICAN ENERGY COMPANY By: Title: Accepted this day of , 2021 APPLICANT: By: Title: 3241 3233 3242 BB2 ACSR 6/1 (2 ACSR 6/ 1 ) 750 AL PARA 336 ACSR 18/1 (4/0 ACSR 6/1) 750 AL PARA 750 AL PARA 750 AL PARA 1/0 AL JACKETED1/0 AL JACKETED Removed EL203 EL203 EL203 EL203 EL203 EL203 UGCOCUGUGCOCUGCOC             0016877685 SG-JC553 0019433698 PP0098 0019448968 0019588477 45-3 WOOD 45-3 WOOD 45-3 WOOD 45-3 WOOD 40-4 WOOD   65T 200E 200E 200E 30E X626A SG-JC553-06 SG-JC553-05 SG-JC553-04 SG-JC553-02     N948 SOLID BLADE OPEN MD01 SOLID BLADE OPEN MD01 SG-JC553-01 SG-JC553-03  1 - 6.00 - CONTINUOUS POLYETHELYNE 1 - 6.00 - CONTINUOU S P O L Y E T H E L Y N E 1 - 6.00 - CONTINUOUS POLYET H E L Y N E 1 - 2.00 - CONTINUOU S P O L Y E T H E L Y N E     100 600 600 600 25 B PHS 25KVA 120/240 B PHS 25 KVA 120/240 B PHS 25 KVA 120/240 <<<<<      0019588477 1 - 2.00 - CONTINUOU S P O L Y E T H E L Y N E  30E SG-JC553-02EL2031/0 AL JACKETED B PHS 25 KVA 120/240   1/0 AL JACKETED EL203 0019588477 B PHS 25 KVA 120/240  30E 1 - 2.00 - CONTINUOU S P O L Y E T H E L Y N E  SG-JC553-02 1 3 5 7    VERMILLION CT3256 1150 3257 3261 3251 3255 P B BB 2 ACSR 6/1 (2 ACSR 6/1)2 ACSR 6/1 (2 ACSR 6 / 1 ) 2 AC SR 6 / 1 ( 2 AC SR 6 / 1 )1/0 ACSR 6/1 (1/0 ACSR 6/1)2 ACSR 6/1 (2 ACSR 6/1)4A COPPERWELD 3W (4A COPPERWELD 3W)2 ACSR 6/1 (2 ACSR 6/1)COMMON NEUTRAL750 AL PARA 4/0 AL PARA750 AL PARA 750 AL PARA 750 AL PARA 4/0 AL PARA4/0 AL PARA 1/0 AL JACKETED1/0 AL JACKETED 1/0 AL JACKETED 1/0 AL JACKETEDRemovedEL203EL203 EL203 EL203EL203 EL203 EL203 EL203EL203 EL203EL203 EL203 EL203UG COC COCUGCOCUGCOCU G C O C 1 2 0 / 2 0 8 SIREN CTV                        0016877685 3247 Ashworth P.E. 0018624037 PP0098 0019448968 SG-JC556 0019448975 PP0099 0019449211 0017685381 SG-JC554 0019449078 0019449109 45-3 WOOD 45-3 WOOD45-3 WOOD 45-3 WOOD 45-3 WOOD 45-3 WOOD 35-5 WOOD 45-3 WOOD 35-5 WOOD 0004015577 X619 0016728809                    65T 65T 65T 65T 65T 65T 65T 65T 65T 65T 65T 140T 140T 30E 200E 200E U150 X617 X619 X617A MD02 U150 X617B X626B X626A X733 X619 X028 PH37 SG-JC554-05 SG-JC554-02 SG-JC554-04      MD02 X626 JC555 SG-JC554-03 SG-JC554-06 SG-JC554-01    1 - 2.00 - CONTINUOUS P O L Y E T H E L Y N E 1 - 4.00 - CONTINUOUS POLYETHELYNE 1 - 6.00 - CONTINUO U S P O L Y E T H E L Y N E 1 - 4.00 - CONTINUOUS POLYETHELYNE1 - 6.00 - CONTINUOU S P O L Y E T H E L Y N E 1 - 6.00 - CONTINUOUS POLYETHELYNE 1 - 2.00 - CONTINUOU S P O L Y E T H E L Y N E             600 600 900 600 600 600 25 B PHS 25KVA 120/240 300 B PHS 25 KVA 120/240 CONDUITS & TRACER WIRE STUBBED AT THIS LOCATION LOCATOR NEEDS TO LOCATE THESE CONDUITS CONDUITS & TRACER WIRE STUBBED AT THIS LOCATION LOCATOR NEEDS TO LOCATE THESE CONDUITS CONDUITS & TRACER WIRE STUBBED AT THIS LOCATION LOCATOR NEEDS TO LOCATE THESE CONDUITS <<<< <<<<<                     1 - 2.00 - CONTINUOU S P O L Y E T H E L Y N E EL203 EL203EL2031/0 AL JACKETED 1/0 AL JACKETEDB PHS 25 KVA 120/240 1/0 AL JACKETED 1/0 AL JACKETEDEL203 EL203B PHS 25 KVA 120/240 1 - 2.00 - CONTINUOU S P O L Y E T H E L Y N E 4 6