HomeMy WebLinkAbout2019-04-01-J12 Lot 2 The Shops at Kettlestone North Plat 6_Site Plan AGENDA ITEM:
CITY OF WAUKEE, IOWA
CITY COUNCIL MEETING COMMUNICATION
MEETING DATE: April 1, 2019
AGENDA ITEM: Consideration of approval of a resolution approving a site plan for Lot 2, The
Shops at Kettlestone North Plat 6 (2540 SE Encompass Drive)
FORMAT: Resolution
SYNOPSIS INCLUDING PRO & CON: Vertical Group, applicant, with Kettleview, LLC, property
owner, request approval of a site plan to allow for the construction of a two-
story office building. The proposed building is 6,642 square feet in area.
Access to the site will be provided off of a short extension of SE Encompass
Drive. A total of 27 parking spaces are required for the proposed use of the
site and the site plan identifies a total of 34 parking spaces.
The applicant has provided elevations for the proposed building on the site,
which meets the intent of the architectural guidelines within the Site Plan
Ordinance and the Kettlestone Design Guidelines. The building will feature
fiber cement siding, glazing, and architectural metal paneling.
FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS:
COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning
Commission reviewed this project at the March 12, 2019 Commission Meeting and
recommended approval subject to remaining staff comments:
Approval of a Site Plan for Lot 2, the Shops at Kettlestone North Plat 6 (2540 SE Encompass
Drive)
Senior Planner, Andy Kass, introduced the request for approval of a site plan as made by the applicant,
Vertical Group. The subject property in located east of SE Parkview Crossing Drive and south of SE
Tallgrass Lane, containing approximately 0.60 acres. Mr. Kass reminded the Commission that the area
was rezoned in 2018 to allow for some mixed uses within the professional office park intent of the
development.
The site plan identifies a two-story office building approximately 6,642 square feet in size and a
maximum height of 34 feet. Both floors of the building include office space for the proposed tenant
and the second floor also houses a roof top patio on the south side of the building. The site plan also
identifies an area to the north of the building as an area for future expansion if needed. The trash
enclosure is proposed on the north side of the building.
Access will be provided on the east side of the site off of SE Encompass Drive, a private street, with
an additional access on the south side of the site from a private drive that will be constructed at the
same time as SE Encompass Drive. A 10 foot wide trail will be constructed along the west side of SE
J12
Parkview Crossing Drive, and sidewalks will be constructed along the internal private streets. All
public utilities will service the site, and storm water detention will be provided in the regional
detention basin located to the northeast of the subject property which is owned and maintained by the
City. At this time the site plan meets the open space, landscaping, lighting, and parking requirements.
Staff recommends approval of the site plan subject to any remaining staff comments.
Commissioner Broderick questioned if there was a specific user intended or if it was to be a
“Spec” building. Mr. Kass advised that an insurance company was identified as the intended
user of the space.
Commissioner Hoifeldt questioned if, with the Planned Development, no bar or restraunt was
allowed in this space, just office use. Mr. Kass advised that was correct.
Commissioner Hoifeldt questioned if there was an angle that the mechanical equipment could
be seen. Mr. Kass advised staff would verify with the architect and make sure that was not the
case.
Commissioner Broderick questioned if the applicants have consulted with a waste hauler
company to insure the ability to reach the trash enclosure. A representative for the applicant,
Derek Johnson, advised that the calculations for turn radius of a typical waste hauler vehicle
have been run and show no issues.
Commissioner Koshy asked for more information about the possible expansion area. Mr. Kass
advised that it is a proposed area that if an expansion were to occur it is anticipated to the
north of the site. Any future expansions would have to conform to the parking and open space
requirements for the added square footage.
Commissioner Tietz moved to approve the site plan for Lot 2, The Shops at Kettlestone North Plat 6
(2540 SE Encompass Drive) subject to any remaining staff comments. Commissioner Broderick
seconded the motion. Ayes: Tietz, Streit, Broderick, Hoifeldt, and Koshy. Nays: None. Motion Carries.
STAFF REVIEW AND COMMENT: Staff recommends approval subject to remaining staff
comments.
RECOMMENDATION: Approve the resolution subject to remaining staff comments.
ATTACHMENTS: I. Proposed Resolution
II. Staff Report
III. Site Plan & Elevations
PREPARED BY: Andy Kass, Senior Planner
REVIEWED BY:
THE CITY OF WAUKEE, IOWA
RESOLUTION 19-
APPROVING THE SITE PLAN FOR LOT 2, THE SHOPS AT KETTLESTONE NORTH
PLAT 6 (2540 SE ENCOMPASS DRIVE)
IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA
WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal
Organization; AND,
WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of
the Site Plan for Lot 2, The Shops a Kettlestone North Plat 6, subject to remaining staff
comments on March 12, 2019; AND,
WHEREAS, the Site Plan for Lot 2, The Shops at Kettlestone North Plat 6 is in general
conformance with §304 – Site and Building Development Standards Ordinance of the Waukee
Municipal Code; AND,
WHEREAS, the Site Plan for Lot 2, The Shops at Kettlestone North Plat 6 is in general
conformance with §301.27(A) – Landscaping and Open Space Ordinance of the Waukee
Municipal Code; AND,
NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on
this 1st day of April, 2019 that the Site Plan for Lot 2, The Shops at Kettlestone North Plat 6 is
approved, subject to remaining staff comments.
____________________________
William F. Peard, Mayor
Attest:
___________________________________
Rebecca D. Schuett, City Clerk
RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN
Anna Bergman
R. Charles Bottenberg
Courtney Clarke
Shelly Hughes
Larry R. Lyon
PLANNING AND ZONING COMMISSION STAFF REPORT
PROJECT: Lot 2, The Shops at Kettlestone North
Plat 6 – Site Plan
PREPARED BY: Andy Kass, AICP – Senior Planner
REPORT DATE: March 8, 2019
MEETING DATE: March 12, 2019
GENERAL INFORMATION
Applicant / Owner: Kettleview, LLC (owner) & Vertical Group
(applicant)
Engineer: Derek Johnson, P.E., with ISG
Request: The applicant is requesting approval of a site plan
for an office building.
Location and Size: Property is located east of SE Parkview Crossing
Drive and south of SE Tallgrass Lane, containing
approximately 0.60 acres.
Property Address: 2540 SE Encompass Drive
AREA MAP
ABOVE: Aerial of subject property (outlined in BLUE) in relation to the surrounding area.
March 8, 2019
2 of 3
LAND USES AND ZONING
Location Existing Land Use Comprehensive Plan Current Zoning
Property in
Question
Vacant – Undeveloped Office K-OF (Kettlestone Office) /
PD-1 (Planned
Development Overlay)
North Vacant – Undeveloped Multi-Family Stacked
Medium and Office
A-1 (Agricultural District)
South Vacant – Undeveloped Community Commercial K-RC (Kettlestone Retail
Community District)
East Holmes Murphy Office K-OF (Kettlestone Office
District)
West Vacant – Undeveloped Office K-OF (Kettlestone Office
District)
HISTORY
The proposed project is located within Kettleview Development that was rezoned in 2018. The overall
development is intended to be a professional office park. The proposed office building is the second building
proposed within the development. In 2018, a site plan for a dental office building was approved which is
currently under construction.
PROJECT DESCRIPTION
The site plan identifies the construction of a 6,642 square foot office building. The proposed building is two
stories with an overall maximum height of 34-feet. Both floors of the building include office space for the
proposed tenant. In addition to office space and conference rooms, the proposed building will feature a
rooftop patio on the south side of the building. The site plan also identifies an area to the north of the building
that identifies an area for future expansion. Future expansion of the building will require site plan review and
approval. The trash enclosure is proposed to be located on the north side of the building.
ACCESS AND PARKING
Access to the property will be provided on the east side of the site off of SE Encompass Drive, a private
street. SE Encompass Drive which will be constructed at the same time the improvements to the site are
being made. Additional access to the site is provided on the south side off of a private drive that will be
constructed at the same time as SE Encompass Drive.
A total of 27 parking spaces are required for the site and the site plan identifies a total of 32 parking spaces.
The site plan identifies three (3) bike racks to accommodate bike parking on the southwest side of the
building.
SIDEWALKS/TRAILS
A 10-foot-wide trail will be constructed along the west side of SE Parkview Crossing Drive. 5-foot-wide
sidewalks will be constructed along the private internal streets to allow for pedestrian accessibility throughout
the Kettleview development.
UTILITIES
Sanitary sewer service will be provided from a manhole at the southeast corner of the intersection of SE
Tallgrass Lane and SE Parkview Crossing Drive. A public water main that will provide domestic and fire service
to the site will be constructed along with the associated street improvements for the overall development.
March 8, 2019
3 of 3
Storm water detention will be provided in the regional detention basin located to the northeast of the subject
property. The regional detention basin is owned and maintained by the City.
LANDSCAPING & OPEN SPACE
A minimum of 25% of the project area is required to be open space. The total amount of open space
proposed is 28%. The plantings shown on the landscape plan meet the minimum requirements of the
Landscape & Open Space Ordinance and the Kettlestone Design Guidelines.
ELEVATIONS
The proposed building includes glazing, architectural metal paneling, three different varieties of fiber cement
paneling, and a steel awning. The trash enclosure will incorporate the same siding that will be used on the
building. Proposed elevations are attached for your review. The proposed materials and elevations meet the
requirements of the Kettlestone Design Guidelines.
PHOTOMETRIC PLAN
The site plan includes a photometric plan for the proposed site lighting. A total of three (3) pole mounted lights
are proposed for parking lot lighting. These proposed fixtures comply with the lighting requirements within the
Kettlestone Design Guidelines. In addition to the parking lot lighting the photometric plans identifies two (2) wall
pack light fixtures on the building. These fixtures comply with the requirements of the Kettlestone Design
Guidelines.
STAFF RECOMMENDATION
Staff recommends approval of the site plan for Lot 2, The Shops at Kettlestone North Plat 6 subject to
remaining staff comments.
Private Storm
S
e
w
e
r
E
a
s
e
m
e
n
t
per Bk 2018
P
g
2
1
9
9
4
Pub
l
i
c
W
a
t
e
r
M
a
in
E
a
s
em
e
n
t
pe
r
B
k
2
0
1
8
P
g
2
2
2
3
1
Priv
a
t
e
S
t
o
rm
S
e
w
e
r
E
a
s
e
m
e
n
t
pe
r
B
k
2
0
1
8
P
g
2
1
9
9
4 Public
U
t
i
l
i
t
ies
E
a
s
emen
t
pe
r
Bk
2
0
1
8
Pg
2
2
2
3
0
FUTURE TRAIL(BY OTHERS)
22652 C0-SITE DATA
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
PROJECT LOCATION
ADDRESS:
2540 ENCOMPASS DRIVE
LEGAL DESCRIPTION:
LOT 2 OF THE SHOPS AT KETTLESTONE
NORTH PLAT 6
LEGEND
EXISTING
CITY LIMITS
ACCESS CONTROL
SECTION LINE
QUARTER SECTION LINE
RIGHT OF WAY LINE
PROPERTY / LOTLINE
EASEMENT LINE
CULVERT
WATER EDGE
WETLAND BOUNDARY
WETLAND / MARSH
WATER
FENCE LINE
STORM SEWER
SANITARY SEWER
SANITARY SEWER FORCEMAIN
CONTOUR (MAJOR)
UNDERGROUND TELEPHONE
OVERHEAD ELECTRIC
UNDERGROUND ELECTRIC
UNDERGROUND TV
GAS
UNDERGROUND FIBER OPTIC
CONTOUR (MINOR)
DECIDUOUS TREE
CONIFEROUS TREE
TREE LINE
MANHOLE/STRUCTURE
CATCH BASIN
HYDRANT
CURB STOP
VALVE
UTILITY PEDESTAL / CABINET
POWER POLE
990
989
PROPOSED
CULVERT
STORM SEWER
SANITARY SEWER
WATER
OVERHEAD ELECTRIC
UNDERGROUND ELECTRIC
UNDERGROUND TV
GAS
CONTOUR
MANHOLE
CATCH BASIN
HYDRANT
VALVE
EASEMENT
RIGHT OF WAY
STORM SEWER (PIPE WIDTH)
1015
LOT LINE
SANITARY SEWER (PIPE WIDTH)
OVERHEAD UTILITY
UNDERGROUND UTILITY
1.ALL WORK SHALL CONFORM TO THE CONTRACT DOCUMENTS, WHICH INCLUDE, BUT
ARE NOT LIMITED TO, THE OWNER - CONTRACTOR AGREEMENT, THE PROJECT MANUAL
(WHICH INCLUDES GENERAL SUPPLEMENTARY CONDITIONS AND SPECIFICATIONS),
DRAWINGS OF ALL DISCIPLINES AND ALL ADDENDA, MODIFICATIONS AND CLARIFICATIONS
ISSUED BY THE ARCHITECT/ENGINEER.
2.CONTRACT DOCUMENTS SHALL BE ISSUED TO ALL SUBCONTRACTORS BY THE
GENERAL CONTRACTOR IN COMPLETE SETS IN ORDER TO ACHIEVE THE FULL EXTENT AND
COMPLETE COORDINATION OF ALL WORK.
3.WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. NOTIFY
ARCHITECT/ENGINEER OF ANY DISCREPANCIES OR CONDITIONS REQUIRING INFORMATION
OR CLARIFICATION BEFORE PROCEEDING WITH THE WORK.
4.FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS. NOTIFY
ARCHITECT/ENGINEER OF ANY DISCREPANCIES OR CONDITIONS REQUIRING INFORMATION
OR CLARIFICATION BEFORE PROCEEDING WITH THE WORK.
5.DETAILS SHOWN ARE INTENDED TO BE INDICATIVE OF THE PROFILES AND TYPE OF
DETAILING REQUIRED THROUGHOUT THE WORK. DETAILS NOT SHOWN ARE SIMILAR IN
CHARACTER TO DETAILS SHOWN. WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN
INTENT CANNOT BE DETERMINED, NOTIFY ARCHITECT/ENGINEER BEFORE PROCEEDING
WITH THE WORK.
6.ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE APPLIED,
INSTALLED, CONNECTED, ERECTED, CLEANED AND CONDITIONED ACCORDING TO
MANUFACTURERS' INSTRUCTIONS. IN CASE OF DISCREPANCIES BETWEEN
MANUFACTURERS' INSTRUCTIONS AND THE CONTRACT DOCUMENTS, NOTIFY
ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE WORK.
7.ALL DISSIMILAR METALS SHALL BE EFFECTIVELY ISOLATED FROM EACH OTHER TO
AVOID GALVANIC CORROSION.
8.THE LOCATION AND TYPE OF ALL INPLACE UTILITIES SHOWN ON THE PLANS ARE FOR
GENERAL INFORMATION ONLY AND ARE ACCURATE AND COMPLETE TO THE BEST OF THE
KNOWLEDGE OF I & S GROUP, INC. (ISG). NO WARRANTY OR GUARANTEE IS IMPLIED. THE
CONTRACTOR SHALL VERIFY THE SIZES, LOCATIONS AND ELEVATIONS OF ALL INPLACE
UTILITIES PRIOR TO CONSTRUCTION. CONTRACTOR SHALL IMMEDIATELY NOTIFY
ENGINEER OF ANY DISCREPANCIES OR VARIATIONS FROM PLAN.
9.THE CONTRACTOR IS TO CONTACT "IOWA ONE CALL" FOR UTILITY LOCATIONS,
MINIMUM 2 BUSINESS DAYS PRIOR TO ANY EXCAVATION / CONSTRUCTION (1-800-292-8989).
PROJECT GENERAL NOTES
HORIZONTAL COORDINATES HAVE BEEN REFERENCED TO THE NORTH AMERICAN DATUM
OF 1983 (NAD83), ZONE 8, ON THE IOWA REGIONAL COORDINATE SYSTEM, IN U.S. SURVEY
FEET. ELEVATIONS HAVE BEEN REFERENCED TO THE NORTH AMERICAN VERTICAL DATUM
OF 1988 (NAVD 88). RTK GPS METHODS WERE USED TO ESTABLISH HORIZONTAL AND
VERTICAL COORDINATES FOR THIS PROJECT.
THIS PROJECT'S TOPOGRAPHIC SURVEY CONSISTS OF DATA COLLECTED IN JUNE, 2018 BY
LANDMARK ENGINEERING GROUP AND BETWEEN AUGUST & NOVEMBER OF 2018 BY ISG.
SPECIFICATIONS REFERENCE
PROJECT DATUM
TOPOGRAPHIC SURVEY
ALL CONSTRUCTION SHALL COMPLY WITH THE PROJECT SPECIFICATIONS, THE CITY OF
WAUKEE STANDARD SPECIFICATIONS AND THE STATEWIDE URBAN DESIGN AND
SPECIFICATIONS (SUDAS), 2019 EDITION, UNLESS DIRECTED OTHERWISE.
02/19/2019 SITE PLAN REVIEW - 2ND PJJ
SITE DATA
-
PJJ
RJA
DAJ
SITE PLAN 02/01/19
19-22652
C0-10 SITE DATA
---- ---- C0-10
SITE SUMMARY
ZONING:K-OF/PD-1
SITE/LOT AREA:26,171 SF / 0.60 AC.
IMPERVIOUS AREA:18,743 SF / 0.43 AC.
GREENSPACE
PROVIDED:7,428 SF / 0.17 AC. (REQUIRED 25%)
FLOOR AREA RATIO:0.20 (MAXIMUM 0.35)
BIKE PARKING:3 RACKS
EMPLOYEES:15
SQUARE FOOTAGE:6,642 SF
BUILDING HEIGHT:34'-0"
CONSTRUCTION
TYPE:VB
PARKING REQUIREMENTS (PER CITY CODE)
TYPE UNIT / AREA STALLS REQUIRED STALLS PROVIDED
STANDARD 1/250 GFA 25 32
H.C.2 2
TOTAL:27 34
SETBACKS
BUILDING ACCESSORY
STRUCTURE
FRONT YARD 0'-0"20'-0"
SIDE YARD 0'-0"5'-0"
REAR YARD 0'-0"5'-0"
WAUKEE IOWA
C0-10
LOT 2
THE SHOPS AT
KETTLESTONE
NORTH PLAT 6
B.M. ELEVATION=1032.32
BURY BOLT ON FIRE HYDRANT,
EAST SIDE OF GRAND PRARIE PARKWAY,
790' NORTH OF S.E. ESKER RIDGE DRIVE
PRELIMINARY NOT FOR CONSTRUCTION PRELIMINARY NOT FOR CONSTRUCTIONN
S
W E
LOCATION MAP
0
SCALE IN FEET
500 1000
CITY OF
WAUKEE, IA
PROJECT MANAGER:
ISG - RYAN ANDERSON
7900 INTERNATIONAL DRIVE, SUITE 550
MINNEAPOLIS, MN 55425
PHONE: 952-426-0699
APPLICANT:
VERTICAL GROUP
327 NORTH RIVERFRONT DRIVE
MANKATO, MN 56001
PHONE: 507-525-3531
PROPERTY OWNER:
KETTLEVIEW, LLC
4700 150 STREET
URBANDALE, IA 50323
PRINTED SIGNATURE
SIGNATURE SIGNATURE DATE
REGISTRATION EXPIRES
SEAL
TSIGEWE LA
NOISSEFORP
RDERIO A NREENIGEI HEREBY CERTIFY THAT THIS ENGINEERING
DOCUMENT WAS PREPARED BY ME OR UNDER MY
DIRECT PERSONAL SUPERVISION AND THAT I AM A
DULY LICENSED PROFESSIONAL ENGINEER UNDER
THE LAWS OF THE STATE OF IOWA.
SHEETS COVERED BY THIS SEAL
DEREK A.
JOHNSON
20894
DEREK A. JOHNSON
C0-10 - C6-10
ASHWORTH ROA
D GRAND PRAIRIE PKWYSE TALLGRASS L
N
SE WESTOWN PK
W
Y
SE LA GRANT PKWYCIVIL SHEET INDEX
C0-10 SITE DATA
C0-11 GENERAL SITE NOTES
C0-20 SITE DETAILS
C0-21 SITE DETAILS
C0-22 SITE DETAILS
C1-10 TEMPORARY EROSION & SEDIMENT CONTROL PLAN
C1-20 EROSION & SEDIMENT CONTROL PLAN NOTES
C1-21 EROSION & SEDIMENT CONTROL PLAN DETAILS
C2-10 EXISTING SITE PLAN
C3-10 SITE PLAN
C3-20 SITE UTILITY PLAN
C3-21 HYDRANT COVERAGE MAP
C4-10 SITE GRADING PLAN
C5-10 SITE PLANTING & RESTORATION PLAN
C5-20 PLANTING & RESTORATION PLAN
C6-10 PHOTOMETRICS PLAN
03/05/2019 SITE PLAN REVIEW - 3RD PJJ
SE E
S
K
E
R
R
I
D
G
E
D
R
I
V
ESE PARKVIEW CROSSING DRIVE03/14/2019 SITE PLAN REVIEW - 4TH PJJ
22652 C0-DETAILS
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
GENERAL SITE
NOTES
C0-11
-
PJJ
RJA
DAJ
SITE PLAN 02/01/19
19-22652
C0-11 GENERAL SITE NOTES
---- ---- C0-11
WAUKEE IOWA
B.M. ELEVATION=1032.32
BURY BOLT ON FIRE HYDRANT,
EAST SIDE OF GRAND PRARIE PARKWAY,
790' NORTH OF S.E. ESKER RIDGE DRIVE
PRELIMINARY NOT FOR CONSTRUCTION PRELIMINARY NOT FOR CONSTRUCTIONLOT 2
THE SHOPS AT
KETTLESTONE
NORTH PLAT 6
03/05/2019 SITE PLAN REVIEW - 3RD PJJ
1.ALL WORK SHALL BE IN ACCORDANCE WITH OSHA CODES AND STANDARDS. NOTHING INDICATED ON THE DRAWINGS SHALL RELIEVE THE CONTRACTOR FROM
COMPLYING WITH ANY APPROPRIATE SAFETY REGULATIONS.
2.ALL WORK SHALL CONFORM TO THE CONTRACT DOCUMENTS. WHICH INCLUDE, BUT ARE NOT LIMITED TO, THE OWNER - CONTRACTOR AGREEMENT, THE
PROJECT MANUAL (WHICH INCLUDES GENERAL SUPPLEMENTARY CONDITIONS AND SPECIFICATIONS), DRAWINGS OF ALL DISCIPLINES AND ALL ADDENDA,
MODIFICATIONS AND CLARIFICATIONS ISSUED BY THE ARCHITECT / ENGINEER.
3.CONTRACT DOCUMENTS SHALL BE ISSUED TO ALL SUBCONTRACTORS BY THE GENERAL CONTRACTOR IN COMPLETE SETS IN ORDER TO ACHIEVE THE FULL
EXTENT AND COMPLETE COORDINATION OF ALL WORK.
4.ALL PROPERTY PINS SHALL BE PROTECTED FROM GRADING OR OTHER OPERATIONS. ANY PINS DISTURBED SHALL BE RESET AT THE CONTRACTOR'S EXPANSE.
5.THE WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND CURRENT EDITION OF THE STATEWIDE URBAN DESIGN AND SPECIFICATIONS
(SUDAS) SHALL APPLY TO CONSTRUCTION WORK ON THE PROJECT. A FULL IOWA SUDAS SPECIFICATIONS MANUAL CAN BE FOUND ONLINE FOR FREE AT
WWW.IOWASUDAS.COM.
6.WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. NOTIFY ARCHITECT / ENGINEER OF ANY DISCREPANCIES OR CONDITIONS REQUIRING
INFORMATION OR CLARIFICATION BEFORE PROCEEDING WITH THE WORK.
7.THE WORK TO BE ACCOMPLISHED FOR THE CONSTRUCTION OF THIS PROJECT WILL OCCUR ON OWNER'S PROPERTY. THE CONTRACTOR SHOULD CONFINE
OPERATIONS, PEOPLE, AND EQUIPMENT TO THE OWNER'S PROPERTY.
8.IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE WASTE AREAS OR DISPOSAL SITES FOR EXCESS MATERIALS NOT TO BE INCORPORATED IN THE
WORK INVOLVED IN THE PROJECT (UNSUITABLE EXCAVATION, WASTE PIPE, ETC.).
9.PUBLIC UTILITY FIXTURES ARE EXISTING WITHIN THE CONSTRUCTION AREA. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE OWNERS OF THESE
UTILITIES PRIOR TO THE BEGINNING OF ANY CONSTRUCTION. THE CONTRACTOR SHALL AFFORD ACCESS TO THESE FACILITIES FOR ANY NECESSARY
MODIFICATION OF SERVICES. NO ADDITIONAL COMPENSATION WILL BE ALLOWED TO THE CONTRACTOR FOR ANY INTERFERENCE OR DELAY CAUSED BY SUCH
WORK.
10.CONTRACTOR SHALL BE RESPONSIBLE FOR GRADING AND PREPARING AREAS DISTURBED BY CONTRACTOR'S OPERATIONS FOR SEEDING. ALL DEBRIS GREATER
THAN GOLF BALL SIZE SHALL BE REMOVED AND AREA SHALL BE RAKED SMOOTH. CONTRACTOR SHALL NOT DISTURB AREAS OUTSIDE OF THE OWNER'S
PROPERTY DURING OPERATIONS AND SHALL MAKE A REASONABLE EFFORT TO NOT DISTURB AREAS GREATER THEN NECESSARY DURING CONSTRUCTION.
AREAS OF NONGERMINATION WILL BE RESEEDED AND REFERTILIZED BY THE CONTRACTOR. COST IS TO BE CONSIDERED INCIDENTAL.
11.IT WILL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY TRAFFIC CONTROL SIGNS, DEVICES, ETC., AND TO PLACE, MAINTAIN, AND REMOVE
SAME AS CONSTRUCTION COMMENCES AND IS COMPLETED IN ACCORDANCE WITH THE CURRENT EDITION OF THE IOWA MANUAL ON UNIFORM TRAFFIC
CONTROL DEVICES FOR STREETS & HIGHWAYS. FAILURE TO COMPLY WITH THIS PORTION OF THE SPECIFICATIONS WILL RESULT IN SUSPENSION OF WORK
UNTIL. THE SITUATION IS CORRECTED. A REDUCTION IN THE LUMP SUM TO BE PAID WILL BE MADE FOR EXCESSIVE NONCOMPLIANCE WITH REQUIRED TRAFFIC
CONTROL. NO WORK SHALL COMMENCE IN ANY GIVEN AREA UNTIL ALL APPROPRIATE TRAFFIC CONTROL IS IN PLACE.
12.THE CONTRACTOR SHALL NOT DISTURB GRASSED AREAS AND TREES OUTSIDE THE CONSTRUCTION LIMITS. TREES AND BUSHES SHALL BE RETAINED AS POSSIBLE.
THE CONTRACTOR WILL NOT BE PERMITTED TO PARK SERVICE VEHICLES AND EQUIPMENT OR USE THESE AREAS FOR STORAGE OF MATERIALS. STORAGE,
PARKING AND SERVICE AREA(S) WILL BE SUBJECT TO APPROVAL OF THE ENGINEER.
13.ALL EXISTING TREES AND BUSHES SHALL BE MAINTAINED AND PROTECTED UNLESS NOTED OTHERWISE. AREAS OF HAND FORMING MAY BE REQUIRED TO
PROTECT TRESS.
14.THE CONSTRUCTION OPERATIONS ARE TO TAKE PLACE IN A RESIDENTIAL AREA. THE CONTRACTOR'S ATTENTION IS DIRECTED TO THE REQUIREMENTS INCLUDED
IN THE SPECIFICATIONS IN REGARD TO POSITIVE DUST CONTROL DURING ALL OPERATIONS TO INCLUDE REMOVAL, CLEAN UP, ETC.
15.CONTRACTOR SHALL PROVIDE BARRICADES AND SIGNS IDENTIFYING VEHICLES AND OBSTACLES IN THE DRIVEN ROADWAYS.
16.FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS, NOTIFY ARCHITECT / ENGINEER OF ANY DISCREPANCIES OR CONDITIONS REQUIRED INFORMATION
OR CLARIFICATION BEFORE PROCEEDING WITH THE WORK.
17.EXISTING STORM SEWERS, SANITARY SEWERS, AND WATER MAINS ARE LOCATED BASED ON CITY RECORDS AND ACTUAL LOCATIONS MAY VARY GREATLY FROM
THAT SHOWN. THE LOCATIONS AND TYPE OF ALL INPLACE UTILITIES SHOWN ON THE PLANS ARE FOR GENERAL INFORMATION ONLY AND ARE ACCURATE AND
COMPLETE TO THE BEST OF THE KNOWLEDGE OF ISG. NO WARRANTY OR GUARANTEE IS IMPLIED. THE CONTRACTOR SHALL VERIFY THE SIZES, LOCATIONS, AND
ELEVATIONS OF ALL INPLACE UTILITIES PRIOR TO CONSTRUCTION. CONTRACTOR SHALL IMMEDIATELY NOTIFY ENGINEER OF ANY DISCREPANCIES OR
VARIATIONS FROM PLAN.
18.CONTRACTOR SHALL REPLACE AND REPAIR ALL EXISTING STORM SEWERS THAT ARE ENCOUNTERED DURING CONSTRUCTION IN ACCORDANCE WITH THE
SPECIFICATION. CONTRACTOR SHALL USE 2000D RCP WITH FLEXIBLE O-RING GASKET JOINTS, PLACE PIPES SO JOINTS ARE NOT DIRECTLY OVER WATER MAIN,
AND RECONNECT TO EXISTING STORM SEWER WITH REINFORCED FERNCO COUPLING.
19.PROPOSED WATER DISTRIBUTION LINE SHALL BE INSTALLED WITH A MINIMUM OF FIVE AND ONE-HALF (5.5') OF COVER. IN LOCATIONS WITH A SEPARATION
DISTANCE OF LESS THAN TEN FEET (10') FROM SANITARY SEWER OR STORM SEWER, THE SANITARY SEWER OR STORM SEWER SHALL BE INSTALLED EIGHTEEN
INCHES (18") BELOW THE BOTTOM OF THE WATER MAIN AND SHALL BE PLACED IN A SEPARATE TRENCH AT A MINIMUM HORIZONTAL SEPARATION OF THREE
FEET PER SUDAS SPECIFICATIONS.
20.AT ALL SANITARY SEWER AND WATER MAIN CROSSOVER, MAINTAIN A MINIMUM OF 18" SEPARATION BETWEEN BOTTOM OF WATER MAIN AND TOP OF
SEWER. PLACE ONE FULL LENGTH OF WATER PIPE, LOCATED SO BOTH JOINTS ARE AS FAR AS POSSIBLE FROM SEWER. USE LOW PERMEABILITY SOIL FOR
BACKFILL WITHIN 10' OF CROSSOVER.
21.THRUST BLOCKS SHALL BE POURED CONCRETE, INSTALLED BEHIND ALL BENDS, TEES AND DEAD ENDS IN ACCORDANCE WITH SPECIFICATIONS.
22.GRANULAR BEDDING IS REQUIRED FOR ANY TYPE OF PIPE USED AND SHALL BE AS SPECIFIED.
23.A NEAT VERTICAL EDGE WILL BE REQUIRED FOR ALL JOINTS BETWEEN THE NEW PAVEMENT SURFACE AND EXISTING PAVING AS SHOWN IN THE PLANS. SAW
CUTTING OR OTHER TECHNIQUES MAY BE USED TO PROVIDE THIS EDGE. COST OF THE SAW CUT IS TO BE CONSIDERED INCIDENTAL. ADDITIONAL REMOVAL
AND REPLACEMENT DUE TO THE CONTRACTOR'S OPERATION WILL BE MEASURED SEPARATELY BUT WILL BE THE CONTRACTOR'S RESPONSIBILITY.
24.ANY DEWATERING NECESSARY FOR CONSTRUCTION SHALL BE CONSIDERED INCIDENTAL TO INDIVIDUAL CONSTRUCTION ITEM. PLEASE REFER TO SUBSURFACE
EXPLORATION REPORT FOR ANTICIPATED SITE CONDITIONS. REPORT IS FOR INFORMATIONAL PURPOSES ONLY AND DOES NOT GUARANTEE CONDITIONS TO BE
EXPERIENCED.
25.THE CONTRACTOR SHALL INSPECT AND VERIFY SOIL CONDITIONS AS NECESSARY IN ORDER TO DETERMINE THE TYPE OF CONSTRUCTION TO EMPLOY. NATURAL
AND/OR MANMADE OBSTRUCTIONS MAY BE ENCOUNTERED IN THE SOIL. THESE CONTRACT DOCUMENTS DO NOT WARRANT THE NATURE OR CONDITIONS OF
THE SOILS, AND DO NOT WARRANT THAT NATURAL OR MANMADE OBSTRUCTIONS WILL NOT BE ENCOUNTERED, NOR GUARANTEE THE EXTENT TO WHICH
ROCKS, BOULDERS, OR OTHER OBSTRUCTIONS, REGARDLESS OF SIZE, MAY BE ENCOUNTERED DURING BORING OPERATIONS. THE CONTRACTOR SHALL NOT BE
ENTITLED TO ADDITIONAL COMPENSATION FOR ANY NATURAL OR MANMADE OBSTRUCTIONS ENCOUNTERED DURING TRENCHLESS CONSTRUCTION.
26.DETAILS SHOWN ARE INTENDED TO BE INDICATIVE OF THE PROFILES AND TYPE OF DETAILING REQUIRED THROUGHOUT THE WORK. DETAILS NOT SHOWN ARE
SIMILAR IN CHARACTER TO DETAILS SHOWN. WHERE SPECIFIC DIMENSIONS, DETAILS, OR DESIGN INTENT CANNOT BE DETERMINED, NOTIFY ARCHITECT /
ENGINEER BEFORE PROCEEDING WITH THE WORK.
27.ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE APPLIED, INSTALLED, CONNECTED, ERECTED, CLEANED, AND CONDITIONED ACCORDING
TO MANUFACTURERS' INSTRUCTIONS. IN CASE OF DISCREPANCIES BETWEEN MANUFACTURERS' INSTRUCTIONS AND THE CONTRACT DOCUMENTS, NOTIFY
ARCHITECT / ENGINEER BEFORE PROCEEDING WITH THE WORK.
28.ALL DISSIMILAR METALS SHALL BE EFFECTIVELY ISOLATED FROM EACH OTHER TO AVOID GALVANIC CORROSION.
29.THE LOCATION AND TYPE OF ALL INPLACE UTILITIES SHOWN ON THE PLANS ARE ACCURATE AND COMPLETE TO THE BEST OF THE KNOWLEDGE OF ISG. NO
WARRANTY OR GUARANTEE IS IMPLIED. THE CONTRACTOR SHALL VERIFY THE SIZES, LOCATIONS AND ELEVATIONS OF ALL INPLACE UTILITIES PRIOR TO
CONSTRUCTION. CONTRACTOR SHALL IMMEDIATELY NOTIFY ENGINEER OF ANY DISCREPANCIES OF VARIATIONS FROM PLAN.
30.THIS SITE WILL HAVE SAWCUTTING AND/OR CONCRETE GRINDING, SO PROTECTION OF STORM SEWERS AND DRAINAGE WAYS WILL NEED TO BE PROTECTED
FROM SLURRY FROM THE CONCRETE OPERATION TO DISCHARGE OFFSITE.
31.THE CONTRACTOR IS TO CONTACT "IOWA ONE CALL" FOR UTILITY LOCATIONS, 48 HOURS PRIOR TO EXCAVATION / CONSTRUCTIONS (1-800-292-8989).
32.ANY PROPOSED CHANGES TO THE PLAN SET SHALL BE APPROVED IN WRITING BY THE CITY OF WAUKEE DEVELOPMENT SERVICES DEPARTMENT.
33.THE CONTRACTOR IS RESPONSIBLE FOR ANY CHANGES MADE DURING CONSTRUCTION THAT HAVE NOT BEEN GRANTED APPROVAL IN WRITING BY THE CITY OF
WAUKEE DEVELOPMENT SERVICES DEPARTMENT.
34.ALL FIRE HYDRANTS ARE TO HAVE 4" STORZ FITTINGS.
35.ALL UTILITIES ARE TO BE CONSTRUCTED TO THE CITY OF WAUKEE STANDARDS.
36.ALL UTILITIES ARE TO BE TESTED TO CITY OF WAUKEE STANDARDS, AND THE CITY IS TO WITNESS ALL TESTING.
37.COORDINATE ALL TIE-INS TO EXISTING UTILITIES WITH CITY OF WAUKEE PUBLIC WORKS DEPARTMENT.
38.APPROVED FIRE APPARATUS ACCESS ROADS SHALL BE PROVIDED AS SOON AS CONSTRUCTION COMMENCES. THE FIRE APPARATUS ROAD SHALL COMPLY WITH
THE REQUIREMENTS OF SECTION 503.2 AND SHALL EXTEND TO WITHIN 100-FEET OF THE EXTERIOR WALLS OF THE BUILDING AS MEASURED BY AN APPROVED
ROUTE AROUND THE EXTERIOR OF THE BUILDING.
CONSTRUCTION NOTES
03/14/2019 SITE PLAN REVIEW - 4TH PJJ
48"1'-0"24"60"36"12" CONCRETE BASE
F&I: HANDICAPPED PARKING SIGN WHICH
MEETS A.D.A. & STATE OF IOWA
REQUIREMENTS.
2" Ø GALVANIZED STEEL POST
CONCRETE FILLED
6" STEEL GUARD POST
24"Ø x 4'-0" DEEP
CONC. PLUG
CONCRETE SLAB (MIN 4000 PSI)
AGGREGATE BASE
IOWA DOT GRADATION NO. 14 SPEC NUMBER 4123
6"8"COMPACTED SUBGRADE
(12" MINIMUM)
CONCRETE SLAB (MIN 4000 PSI)
AGGREGATE BASE
IOWA DOT 14
VARIESVARIESCOMPACTED SUBGRADE
(12" MINIMUM)
CONCRETE SLAB (MIN 4000 PSI)
AGGREGATE BASE
4"6"COMPACTED SUBGRADE
(12" MINIMUM)
ST160
CONCRETE WALK
NTS ST120
STANDARD
CONCRETE PAVEMENT SECTION
NTS
HANDICAPPED SIGN
POST W/BOLLARD
NTS
CONCRETE PAVEMENT W/
INTEGRAL CURB & GUTTER
NTS
CONCRETE CURB & GUTTER
(REFER TO DETAILS FOR DIMENSIONS)
22652 C0-DETAILS
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
SITE DETAILS
C0-20
-
PJJ
RJA
DAJ
SITE PLAN 02/01/19
19-22652
C0-20 SITE DETAILS
---- ---- C0-20
WAUKEE IOWA
B.M. ELEVATION=1032.32
BURY BOLT ON FIRE HYDRANT,
EAST SIDE OF GRAND PRARIE PARKWAY,
790' NORTH OF S.E. ESKER RIDGE DRIVE
PRELIMINARY NOT FOR CONSTRUCTION PRELIMINARY NOT FOR CONSTRUCTION5'-0"
5'-0" min.
5'-0"
5'-0"
02/19/2019 SITE PLAN REVIEW - 2ND PJJ
LOT 2
THE SHOPS AT
KETTLESTONE
NORTH PLAT 6
03/05/2019 SITE PLAN REVIEW - 3RD PJJ
5 feet by 5 feet.
5 feet by
5 feet.
03/14/2019 SITE PLAN REVIEW - 4TH PJJ
TRENCH WIDTH, SEE TABLE
PIPE OD (BC)
0.6 BC12"0.15 BC
BACKFILL
COMPACTED
1
1
1
1
BACKFILL W/GRANULAR
MATERIAL OR SELECT
MATERIAL FROM EXCAVATION
PIPE HAUNCHES
STORM DRAIN PIPE
6" GRANULAR BEDDING
C
TRENCH WIDTH
BC + 24"
BC + 36"
PIPE DIAM
36" OR LESS
42" TO 54"
60" OR OVER
1.5 x B
TRENCH WIDTHNOTE:
GRANULAR BEDDING AND BACKFILL FOR
STORM DRAIN PIPES SHALL BE INCIDENTAL
TO STORM DRAIN CONSTRUCTION
TRENCH WIDTH, SEE TABLE
0.6 BC
0.15 BC
BACKFILL
COMPACTED
1
1
1
1
6" GRANULAR BEDDING
C
TRENCH WIDTH
BC + 24"
BC + 36"
PIPE DIAM
36" OR LESS
42" TO 54"
60" OR OVER
1.5 x B
TRENCH WIDTHNOTE:
GRANULAR BEDDING AND BACKFILL FOR
STORM DRAIN PIPES SHALL BE INCIDENTAL
TO STORM DRAIN CONSTRUCTION
PIPE OD (BC)12"STORM DRAIN PIPE
8"18"6"13 12"6"
3
1
R3"
R12"
R3"
HORIZONTAL LINE7"2
NOTES:
LONGITUDINAL JOINT WHEN ADJACENT TO RIGID PAVEMENT OR BASE.
SLOPE 0.06FT/FT NORMAL, UNLESS OTHERWISE SPECIFIED. IF A DIFFERENT GUTTER SLOPE IS
PERMITTED, THE FORM MAY BE TILTED.
1
2
1
CONCRETE CURB & GUTTER
NTS
B618
ST206 4"12"18"7"HORIZONTAL LINE
1
3
2
1
R12"
NOTES:
LONGITUDINAL JOINT WHEN ADJACENT TO RIGID PAVEMENT OR BASE.
SLOPE 0.06FT/FT NORMAL, UNLESS OTHERWISE SPECIFIED. IF A DIFFERENT GUTTER SLOPE IS
PERMITTED, THE FORM MAY BE TILTED.
1
2
CONCRETE CURB & GUTTER
NTS
D418
ST216
NON-CONCRETE STORM DRAIN PIPE BEDDING
NTS SD601
RCP STORM DRAIN PIPE BEDDING
NTS
22652 C0-DETAILS
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
SITE DETAILS
C0-21
-
PJJ
RJA
DAJ
SITE PLAN 02/01/19
19-22652
C0-21 SITE DETAILS
---- ---- C0-21
WAUKEE IOWA
B.M. ELEVATION=1032.32
BURY BOLT ON FIRE HYDRANT,
EAST SIDE OF GRAND PRARIE PARKWAY,
790' NORTH OF S.E. ESKER RIDGE DRIVE
PRELIMINARY NOT FOR CONSTRUCTION PRELIMINARY NOT FOR CONSTRUCTION02/19/2019 SITE PLAN REVIEW - 2ND PJJ
LOT 2
THE SHOPS AT
KETTLESTONE
NORTH PLAT 6
03/05/2019 SITE PLAN REVIEW - 3RD PJJ
03/14/2019 SITE PLAN REVIEW - 4TH PJJ
12"ODOD+24" MAX 6"NOTE:
GRANULAR BEDDING AND ENCASEMENT FOR
SANITARY SEWER SHALL BE INCIDENTAL TO
CONSTRUCTION
COMPACTED
BACKFILL
GRADE
DROP LID
TOP
BOTTOM
EXTENSION
BASE
CAP TO BE SET 12" BELOW GRADE
AND ENCASE IN CONCRETE.
BOX TO BE SET WITH
12" OF ADJUSTMENT.
RESILIANT WEDGE VALVE
CONFORMING TO AWWA
C-509-80 STANDARDS
GATE VALVE,
BOX SCREW TYPE THREE PIECE,
51 4" SHAFT SIZE G BOX,
7'6" EXTENDED,
#6 STANDARD BASE
GATE VALVE ADAPTOR
ALL GATE VALVES SHALL
BE IN ACCORDANCE WITH
CITY OF
STANDARDS
GATE VALVE
ADAPTER
1-1/2" WASHED ROCK
(INCIDENTAL)
MEGALUG
CONC BLOCKING
WATERMAIN PIPE BEDDING
(SEE DETAIL)
NOTES:
INSTALL TOP NUT EXTENDER TO 7' DEPTH ON ALL VALVES WITH OVER-DEPTH
TYPICAL
GATE VALVE & BOX INSTALLATION
NTS WM200
WAUKEE
SD400NTS
VERTICAL RAIN LEADER
4" PERIMETER DRAIN
HORIZONTAL ROOF DRAIN,
SIZE VARIES.
6" PVC LEADER
45° FITTING
6" PVC REDUCER
4" DOWNSPOUTBUILDING LINE
FINISH FLOOR
(SEE PLANS)
-NTS
BIKE RACK
PIPE BEDDING DETAIL FOR
SANITARY SEWER
NTS
22652 C0-DETAILS
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
SITE DETAILS
C0-22
-
PJJ
RJA
DAJ
SITE PLAN 02/01/19
19-22652
C0-22 SITE DETAILS
---- ---- C0-22
B.M. ELEVATION=1032.32
BURY BOLT ON FIRE HYDRANT,
EAST SIDE OF GRAND PRARIE PARKWAY,
790' NORTH OF S.E. ESKER RIDGE DRIVE
PRELIMINARY NOT FOR CONSTRUCTION PRELIMINARY NOT FOR CONSTRUCTIONWAUKEE IOWA
02/19/2019 SITE PLAN REVIEW - 2ND PJJ
LOT 2
THE SHOPS AT
KETTLESTONE
NORTH PLAT 6
03/05/2019 SITE PLAN REVIEW - 3RD PJJ
03/14/2019 SITE PLAN REVIEW - 4TH PJJ
Sanitary Sewer EasementPer The Shops AtKettlestone North Plat 110
10' PUE
BK2019 PG1138
10' PUE
BK2019 PG1138
15' Public Water Main Easement
BK2019 PG1137
20' Private Sanitary Sewer Easement
BK2019 PG1139
20
OFFICE
BUILDING
(3,959 1ST FLOOR SF)
(6,642 TOTAL SF)
FFE=1038.50
Proposed 24'
Access Easement
Proposed 24'
Access Easement
Proposed 20' Private
Sanitary Sewer Easement
FUTURE TRAIL
(BY OTHERS)
1
0
3
91038 10371036103510401039104110411040104010381039103910391040103910381037 103710371
0
3
6
1
0
3
5
1
0
3
1
1
0
3
2
10
3
3
1
0
3
4
1
0
3
5
1
0
3
6
1
0
3
7
1
0
3
8
1
0
3
9
1
0
4
0
10411042103810371
0
3
6
1
0
3
5
10371035103410331031103810391037
1038
10391037FUTURE TRAIL
(BY OTHERS)
22652 C1-SWPPP
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
TEMPORARY
EROSION &
SEDIMENT
CONTROL PLAN
C1-10
-
PJJ
RJA
DAJ
SITE PLAN 02/01/19
19-22652
C1-10 TEMPORARY EROSION & SEDIMENT CONTROL PLAN
---- ---- C1-10
EXISTING PROPERTY LINE, TYP.
B.M. ELEVATION=1032.32
BURY BOLT ON FIRE HYDRANT,
EAST SIDE OF GRAND PRARIE PARKWAY,
790' NORTH OF S.E. ESKER RIDGE DRIVE
PRELIMINARY NOT FOR CONSTRUCTION PRELIMINARY NOT FOR CONSTRUCTIONEROSION CONTROL LEGEND
SYMBOL ITEM NO.DESCRIPTION UNITS QUANTITY
9040-108-G-0 PERIMETER CONTROL LF 1,215
9040-108-T-0 PROPOSED STORM DRAIN INLET
PROTECTION EACH 7
9040-108-O-0 STABILIZED CONSTRUCTION EXIT EACH 1
11,050-108-A-0 CONCRETE WASHOUT AREA EA 1
EXISTING DRAINAGE ARROW
PROPOSED DRAINAGE ARROW
PERIMETER CONTROL CAN BE SILT FENCE, SEDIMENT CONTROL LOG.
QUANTITIES ARE FOR INFORMATIONAL PURPOSES TO MEET THE REQUIREMENTS OF THE CONSTRUCTION
STORMWATER PERMIT. NO GUARANTEE IS MADE TO THE ACTUAL QUANTITIES REQUIRED.
THE QUANTITIES SHOWN ARE TOTAL FOR THE ENTIRE PROJECT NOT SPECIFIC TO THIS SHEET.
SEE SITE RESTORATION PLAN FOR FINAL TURF ESTABLISHMENT
NOTE #1: SWPPP COVERAGE INCLUDES ELECTRIC, GAS, TELEPHONE, AND CABLE INSTALLATION. EACH
COMPANY OR THEIR SUBCONTRACTOR IS RESPONSIBLE TO FOLLOW THE REQUIREMENTS OF THIS SWPPP
INCLUDING PROVIDING THEIR OWN RESTORATION IF INSTALLATION OCCURS AFTER PRIMARY INSTALLATION
OF SEEDING/SODDING/MULCHING DURING CONSTRUCTION OF EACH UTILITY.
NOTE #2: SUDAS TYPE 4 SEED MIX TO BE USED FOR ALL TEMPORARY STABILIZATION (SUDAS 9010) SOD TO BE
USED FOR ALL PERMANENT STABILIZATION (SUDAS 9020) (ESTIMATED QUANTITY = 11,563 SF.)
NOTE #3: REMOVE ALL DEBRIS AND MUD SPILLED INTO ROW AT THE END OF EACH WORK DAY AND PRIOR TO A
RAIN EVENT.
NOTE #4: THE ULTIMATE DISCHARGE LOCATION FOR THE SITE IS FOX CREEK.
EXISTING CONTOUR, TYP.
PROPOSED CONTOUR, TYP.
FUTURE CONTOUR, TYP.
(BY OTHERS)
WAUKEE IOWA
02/19/2019 SITE PLAN REVIEW - 2ND PJJ
LOT 2
THE SHOPS AT
KETTLESTONE
NORTH PLAT 6
03/05/2019 SITE PLAN REVIEW - 3RD PJJ
TOPSOIL STOCKPILE
LOCATION
STAGING/MATERIALS/WASTE
LOCATION
PERIMETER CONTROL OUTLINES
PROJECT DISTURBANCE LIMITS
AREA=1.07 AC.
0
SCALE IN FEET
30 60 90
UNNAMED ACCESS DRIVE SE ENCOMPASS DRIVESE PARKVIEW CROSSING DRIVEFUTURE
DEVELOPMENT
(BY OTHERS)
03/14/2019 SITE PLAN REVIEW - 4TH PJJ
22652 C1-SWPPP
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
EROSION &
SEDIMENT
CONTROL PLAN
NOTES
C1-20
-
PJJ
RJA
DAJ
SITE PLAN 02/01/19
19-22652
C1-20 EROSION & SEDIMENT CONTROL PLAN NOTES
---- ---- C1-20
B.M. ELEVATION=1032.32
BURY BOLT ON FIRE HYDRANT,
EAST SIDE OF GRAND PRARIE PARKWAY,
790' NORTH OF S.E. ESKER RIDGE DRIVE
PRELIMINARY NOT FOR CONSTRUCTION PRELIMINARY NOT FOR CONSTRUCTIONACTIVITY SCHEDULE
Install all BMP's needed and associated with the
Grading Phase such as stabilized construction
entrances, silt basins, riser pipes, outlet pipes silt
traps, silt fence, diversions, terraces, temporary
berms, and etcetera.
Prior to any stripping of existing vegetation or
grading.
Proceed with stripping of existing vegetation and
grading in accordance with the grading plan,
while disturbing no more than necessary.
After Installing all BMP's needed and associated with
the Grading Phase. Furthermore, INSPECTOR
approval must be obtained before the start of any
stripping of existing vegetation or grading.
Proceed with infrastructure installation.
Infrastructure installation must occur prior to any
building construction.
Implement the installation of Temporary Seeding,
Permanent Seeding, and/or Mulching.
Proceed with removal of BMP's.
BMP's may not be removed until each impacted
drainage basin has been fully developed. Full
development shall mean installation of pavement,
buildings, and utilities, landscaping, and fully
established permanent seeding. Furthermore,
INSPECTOR approval must be obtained before the
removal of any BMP's.
CONSTRUCTION ACTIVITIES & SCHEDULING
CONSTRUCTION ACTIVITY NOTES:
EROSION PREVENTION:
Construction of silt fence and all other erosion control measures shall be complete before other
construction activity occurs.
Use phased construction wherever practical and establish turf as soon as possible to minimize
sediment transport.
Turf establishment or temporary seeding or mulching of all exposed soil not being actively worked
should be immediately initiated once earth disturbing activities have ceased.
Temporary cover during construction is incidental.
Pipe outlets must be provided with temporary or permanent energy dissipation within 24 hours after
connection to a surface water.
SEDIMENT CONTROL PRACTICES:
Construction of silt fence and all other erosion control measures shall be complete prior to land
disturbing activities occur.
Inlet erosion protection shall be installed and maintained until turf has been established.
The contractor shall be responsible to control erosion from leaving the construction zone. All
eroded material that leaves the construction zone shall be collected by the contractor and returned
to the site at the contractor's expense.
All streets must be swept at the end of each working day and prior to a rain event.
Silt fence or other effective erosion control measures must be installed around the perimeter of any
soil stockpiles, including temporary stockpiles. Stockpiles cannot be placed in surface waters,
including storm water conveyances such as curb and gutter systems, or conduits and ditches.
Perimeter control shall be installed along the back of curb immediately following curb installation at
all locations with positive drainage to parking lot and/or streets, and shall remain until stabilization is
achieved. This shall be accomplished through the use of silt fence, biorolls, Rock logs, or other
methods approved by the Engineer.
CONSTRUCTION ACTIVITY NOTES:
DEWATERING AND BASIN DRAINING:
Dewater sediment-laden water to sedimentation basins if possible, or use other BMP's to
prevent erosion and remove sediment when discharging to surface waters. Use
appropriate energy dissipation measures on all discharges.
Dewatering practices cannot cause nuisance conditions, erosion or in receiving channels or
inundation of wetlands resulting in adverse impacts.
POLLUTION PREVENTION:
All solid waste collected from the construction site must be disposed in accordance with all
applicable regulations.
All hazardous materials (oil, gasoline, fuel, paint, etc) must be properly stored to prevent
spills, leaks or other discharge, storage areas shall provide secondary containment and a
hazardous materials spill kit. Storage and disposal of hazardous waste must be in
compliance with all applicable regulations.
Equipment maintenance areas must be limited to a defined area of the site. All runoff
containing any hazardous material must be properly collected and disposed. No engine
degreasing shall be allowed on site.
The contractor is responsible for monitoring air pollution and ensuring it does not exceed
levels set by local, state, or federal regulations. This includes dust created by work being
performed on the site. Air pollution and dust control correction is considered incidental to
the unit bid prices for which work is being performed. Additional dust control measures
may be required by the Engineer.
Concrete washout onsite: All liquid waste generated by concrete washout operations
must be contained in a leak-proof containment facility or impermeable liner. The liquid
waste must not contact the ground, and there must not be runoff from the concrete
washout operations or areas. A sign must be installed adjacent to each washout facility to
inform concrete equipment operators to utilize the proper facilities. Protect storm sewers
and drainage ways from allowing concrete slurry from concrete operations to discharge
offsite.
INSPECTION AND MAINTENANCE:
The Permittees must routinely inspect the construction site once every seven (7) days
during active construction.
All inspections performed during construction must be recorded and records retained with
the SWPPP.
Contractor is responsible for keeping a record of all rainfall information & erosion control
maintenance until final establishment of turf.
All silt fences must be repaired, replaced, or supplemented when they become
nonfunctional or the sediment reaches 12 of the height of the fence.
Erosion control, and other BMP's must be replaced, repaired, or supplemented when they
reach 50% design load.
FINAL STABILIZATION:
The Permittees must ensure final stabilization of the site. The Permittees must submit a
notice of termination within 30 days after final stabilization is complete or control has been
passed to another owner.
All temporary erosion control measures and BMP's must be removed as part of the final
site stabilization.
The storm water permit further defines final stabilization and its requirements.
MAINTENANCE SCHEDULE
The following Maintenance Schedule has been provided. The INSPECTOR must perform
the inspections. The OPERATOR/CONTRACTOR must perform all needed maintenance.
Furthermore, all erosion control feature requiring maintenance may not be listed below. The
OPERATOR/CONTRACTOR and INSPECTOR must perform their respective duties on all
BMP's that are not listed below as well.
1.Construction Entrance - The entrance shall be maintained in a condition which
will prevent tracking or flow of sediment onto public rights-of-way. This may
require periodic top dressing with additional stone or the washing and
reworking of existing stone as conditions demand and repair and/or cleanout of
any structures used to trap sediment. All materials spilled, dropped, washed, or
materials dropped, washed or tracked onto roadways will not be permitted
under any circumstances.
2.Wattles - The maintenance measures are as follows: (2.1) wattles shall be
inspected weekly; (2.2) close attention shall be paid to the repair of damaged
bales, end runs and undercutting beneath bales; (2.3) necessary repairs to
barriers or replacement of wattles shall be accomplished promptly; (2.4)
sediment deposits shall be removed after each rainfall, they must be removed
when the level of deposition reaches approximately one-half the height of the
wattle; and (2.5) any sediment deposits remaining in place after the wattle is no
longer required shall be dressed to conform to the existing grade, prepared and
seeded.
3.Silt Fence - The maintenance measures are as follows; (3.1) silt fences shall
be inspected weekly, any required repairs shall be made immediately; (3.2)
close attention shall be paid to the repair of damaged silt fence resulting from
end runs and undercutting; (3.3) should the fabric on a silt fence decompose or
become ineffective prior to the end of the expected usable life and the barrier is
still necessary, the fabric shall be replaced promptly; (3.4) sediment deposits
must be removed when the level of deposition reaches approximately one-half
the height of the barrier; and (3.5) any sediment deposits remaining in place
after the silt fence is no longer required shall be dressed to conform to the
existing grade, prepared and seeded.
4.Storm Drain Inlet Protection - The maintenance measures are as follows: (4.1)
structures shall be inspected weekly and repairs made as necessary and (4.2)
structures shall be removed and the area stabilized when the remaining
drainage area has been properly stabilized.
5.Temporary Seeding - Areas which fail to establish vegetative cover adequate
to prevent rill erosion will be re-seeded as soon as such areas are identified.
6.Permanent Seeding - The maintenance measures are as follows: (10.1) in
general, a stand of vegetation cannot be determined to be fully established until
it has been maintained for one full year after planning; (10.2) new seedlings
shall be supplied with adequate moisture, supply water as needed, especially
late in the season, in abnormally hot or dry conditions, or on adverse sites,
water applications shall be controlled to prevent excessive runoff; (10.3)
inspect all seeded areas for failures and make necessary repairs,
replacements, and reseedings within the planting season, if possible; [10.3.a] if
stand is inadequate for erosion control, over seed and fertilize using half of the
rates originally specified; [10.3.b] if stand is 60% damaged, re-establish
following seedbed and seeding recommendations; [10.3.c] if stand has less
than 40% cover, re-evaluate choice of plant materials and quantities of lime
and fertilizer, the soil must be tested to determine if acidity or nutrient
imbalances are responsible, re-establish the stand following seedbed and
seeding recommendations.
7.Street Cleaning / Sweeping - The maintenance measures are as follows: (13.1)
evaluate access points daily for sediment tracking; (13.2) when tracked or
spilled sediment is found on paved surfaces, it will be removed daily, during
times of heavy track-out, such as during rains, cleaning may be done several
times throughout the day; (13.3) all streets shall be swept at the end of each
working day and prior to a rain event; (13.4) unknown spills or objects will not
be mixed with the sediment; and (13.5) if sediment is mixed with other
pollutants, it will be disposed of properly at an authorized landfill.
Stabilization of disturbed areas must be initiated
immediately whenever any clearing, grading,
excavating, or other earth disturbing activities have
permanently ceased on any portion of the site or
temporarily ceased on any portion of the site and
will not resume for a period exceeding 14 calendar
days.
Stabilization of disturbed areas must be initiated
immediately whenever any clearing, grading,
excavating, or other earth disturbing activities
have permanently ceased on any portion of the
site or temporarily ceased on any portion of the
site and will not resume for a period exceeding 14
calendar days.
WAUKEE IOWA
02/19/2019 SITE PLAN REVIEW - 2ND PJJ
LOT 2
THE SHOPS AT
KETTLESTONE
NORTH PLAT 6
03/05/2019 SITE PLAN REVIEW - 3RD PJJ
03/14/2019 SITE PLAN REVIEW - 4TH PJJ
22652 C1-SWPPP
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
EROSION &
SEDIMENT
CONTROL PLAN
DETAILS
C1-21
-
PJJ
RJA
DAJ
SITE PLAN 02/01/19
19-22652
C1-21 EROSION & SEDIMENT CONTROL PLAN DETAILS
---- ---- C1-21
B.M. ELEVATION=1032.32
BURY BOLT ON FIRE HYDRANT,
EAST SIDE OF GRAND PRARIE PARKWAY,
790' NORTH OF S.E. ESKER RIDGE DRIVE
PRELIMINARY NOT FOR CONSTRUCTION PRELIMINARY NOT FOR CONSTRUCTIONSTANDARD 2"
OVERFLOW AREA 11 GA GALVANIZED STEEL SUSPENSION SYSTEM
LIFT HANDLES
REPLACEABLE SEDIMENT BAGS WITH
GEOTEXTILE FILTER FABRIC
NOTES:
FOR SPECIFICATIONS AND MAINTENANCE GUIDELINES VISIT
WWW.INLETFILTERS.COM
INSTALLATION:
REMOVE GRATE
DROP FLEXSTORM INLET FILTER ONTO LOAD BEARING LIP OF CASTING OR
CONCRETE STRUCTURE
REPLACE GRATE
MATERIALS:
FRAMING - 11 GAUGE STEEL; CORROSION RESISTANT
SEDIMENT BAG - WOVEN GEOTEXTILE FABRIC; 2 CUBIC FOOT TYP VOLUME;
STAINLESS STEEL LOCKING BAND SECURING BAG TO FRAME
RECTANGULAR FILTER
INLET PROTECTION
NTS EC211
2'1' MIN3' DEEP10'NATIVE
MATERIAL
5'x10'x3' CONCRETE
WASHOUT AREA
1' DEEP IMPERVIOUS
CLAY LINER
MINIMUM 10-MIL THICK PLASTIC
SHEETING OR APPROVED
EQUAL
NOTES:
CONTRACTOR SHALL INSTALL A SIGN INDICATING THE CONCRETE WASHOUT AREA.
CONTRACTOR SHALL MAINTAIN WASHOUT AREA TO REMOVE MATERIALS BEYOND 75% CAPACITY.
WASHOUT AREA SHALL NOT BE PLACED WITHIN 50' OF STORM DRAINS, OPEN DITCHES OR BODIES OF WATER.
CONTRACTOR SHALL INSPECT WASHOUT AREA AS NECESSARY TO PREVENT LEAKS AND OVER TOPPING.
WASHOUT AREA SHALL BE REMOVED AFTER CONSTRUCTION IS COMPLETE.
CONCRETE WASHOUT
NTS EC500
WAUKEE IOWA
02/19/2019 SITE PLAN REVIEW - 2ND PJJ
LOT 2
THE SHOPS AT
KETTLESTONE
NORTH PLAT 6
03/05/2019 SITE PLAN REVIEW - 3RD PJJ
03/14/2019 SITE PLAN REVIEW - 4TH PJJ
CB
T/C=1038.45
I=
CB
T/C=1038.40
I=
STM MH
R=1038.54
I=
CB
T/C=1038.41
I=
CB
T/C=1038.31
I=
10
10' PUE
BK2019 PG1138
10' PUE
BK2019 PG1138
15' Public Water Main Easement
BK2019 PG1137
8" WATERMAIN 8" WATERMAIN12" STORM SEWER
24
"
S
T
O
R
M
S
E
W
E
R24" STORM SEWER24" STORMSEWER24" STORM SEWER30" STORM SEWER8" WATER
SERVICE STUB30" STORM SEWER30" STO
R
M
S
E
W
E
R
EXISTING 8" WATERMAINEXISTING 15"
STORM SEWER
20' Private Sanitary Sewer Easement
BK2019 PG1139
20
EXISTING 18"
STORM SEWER
FUTURE TRAIL
(BY OTHERS)1040103910381037 103710371
0
3
6
1
0
3
5
1
0
3
1
1
0
3
2
10
3
3
1
0
3
4
10351
0
3
6
1
0
3
7
1
0
3
8
1
0
3
9
1
0
4
0
10411042103810371
0
3
6
1
0
3
5
1037103510341033103131.09'
70'
22652 C2-EXIST
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
EXISTING SITE PLAN
C2-10
-
PJJ
RJA
DAJ
SITE PLAN 02/01/19
19-22652
C2-10 EXISTING SITE PLAN
---- ---- C2-10
0
SCALE IN FEET
20 40 60
EXISTING PROPERTY LINE, TYP.
UNNAMED ACCESS DRIVE SE ENCOMPASS DRIVEB.M. ELEVATION=1032.32
BURY BOLT ON FIRE HYDRANT,
EAST SIDE OF GRAND PRARIE PARKWAY,
790' NORTH OF S.E. ESKER RIDGE DRIVE
PRELIMINARY NOT FOR CONSTRUCTION PRELIMINARY NOT FOR CONSTRUCTIONEXISTING CONTOUR, TYP.SE PARKVIEW CROSSING DRIVEWAUKEE IOWA
02/19/2019 SITE PLAN REVIEW - 2ND PJJ
LOT 2
THE SHOPS AT
KETTLESTONE
NORTH PLAT 6
03/05/2019 SITE PLAN REVIEW - 3RD PJJ
NOTE:
ENCOMPASS DRIVE & THE UNNAMED ACCESS DRIVE ARE SHOWN FOR
PLANNING PURPOSES ONLY AND ARE NOT PART OF THEIR SITE PLAN
SUBMITTAL.
03/14/2019 SITE PLAN REVIEW - 4TH PJJ
OFFICE
BUILDING
(3,959 1ST FLOOR SF)
(6,642 TOTAL SF)
FFE=1038.50
Proposed 24'
Access Easement
Proposed 24'
Access Easement
Proposed 20' Private
Sanitary Sewer Easement
FUTURE TRAIL
(BY OTHERS)
CB
T/C=1038.45
I=
CB
T/C=1038.40
I=
STM MH
R=1038.54
I=
CB
T/C=1038.41
I=
CB
T/C=1038.31
I=
10
10' PUE
BK2019 PG1138
10' PUE
BK2019 PG1138
15' Public Water Main Easement
BK2019 PG1137
8" WATERMAIN 8" WATERMAIN12" STORM SEWER
24
"
S
T
O
R
M
S
E
W
E
R24" STORM SEWER24" STORMSEWER24" STORM SEWER30" STORM SEWER8" WATER
SERVICE STUB30" STORM SEWER30" STO
R
M
S
E
W
E
R
EXISTING 8" WATERMAINEXISTING 15"
STORM SEWER
20' Private Sanitary Sewer Easement
BK2019 PG1139
20
EXISTING 18"
STORM SEWER
FUTURE TRAIL
(BY OTHERS)
22652 C3-SITE
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
SITE PLAN
C3-10
-
PJJ
RJA
DAJ
SITE PLAN 02/01/19
19-22652
C3-10 SITE PLAN
---- ---- C3-10
0
SCALE IN FEET
20 40 60
UNNAMED ACCESS DRIVE SE ENCOMPASS DRIVESE PARKVIEW CROSSING DRIVEB.M. ELEVATION=1032.32
BURY BOLT ON FIRE HYDRANT,
EAST SIDE OF GRAND PRARIE PARKWAY,
790' NORTH OF S.E. ESKER RIDGE DRIVE
PRELIMINARY NOT FOR CONSTRUCTION PRELIMINARY NOT FOR CONSTRUCTIONEXISTING PROPERTY LINE, TYP.
PAVEMENT LEGEND
SYMBOL DESCRIPTION
CONCRETE PAVEMENT (7")
CONCRETE SIDEWALK
B618 CONCRETE CURB &
GUTTER
REVERSE PITCH B618
CONCRETE CURB & GUTTER
D418 CONCRETE CURB &
GUTTER
11
8
15
6'9'17'24'
F&I: LIGHT POLE,
TYP. OF 3 (SEE C6-10)
CONSTRUCT TRASH ENCLOSURE
(REFER TO ARCHITECTURAL PLANS)80'50'
F&I: ACCESSIBLE PARKING
SIGN & BOLLARD
(TYP. OF 2) (SEE DETAIL)
NOTE: F&I ALL PARKING LOT STRIPING AND
MARKINGS AS SHOWN.
R15'
R15'
R3'R5'R10'
R5'
R4.98'
R5'R5'
(3)BIKE RACK
LANDSCAPE FORMS
STYLE = EMERSON
COLOR = MERCURY
(SEE DETAIL)
CONSTRUCT
D418 CURB & GUTTER
3' TRANSITION FROM B618 CURB & GUTTER
TO D418 CURB & GUTTER
14' TRANSITION FROM D418 CURB &
GUTTER TO B618 CURB & GUTTER
CONSTRUCT REVERSE PITCH
B618 CURB & GUTTER, TYP.
CONSTRUCT B618
CURB & GUTTER, TYP.
6.5' TAPER
7.5' TAPER
ACCESSIBLE PARKING
MARKING (WHITE PAINT)
(TYP. OF 2)
CONSTRUCT PEDESTRIAN CURB
RAMP W/TRUNCATED DOMES (SEE
DETAIL)
STALL COUNT, TYP.
CONSTRUCT CONCRETE
PAVEMENT, TYP.
(SEE DETAIL, SHEET C0-20)
NO PARKING
STRIPING, TYP.
CONSTRUCT CONCRETE
SIDEWALK, TYP.
(SEE DETAIL, SHEET C0-20)
WAUKEE IOWA
02/19/2019 SITE PLAN REVIEW - 2ND PJJ
LOT 2
THE SHOPS AT
KETTLESTONE
NORTH PLAT 6
NOTES:
1.) ENCOMPASS DRIVE & THE UNNAMED ACCESS DRIVE ARE SHOWN
FOR PLANNING PURPOSES ONLY AND ARE NOT PART OF THEIR SITE
PLAN SUBMITTAL.
2.) APPROVED FIRE APPARATUS ACCESS ROADS SHALL BE PROVIDED
AS SOON AS CONSTRUCTION COMMENCES. THE FIRE APPARATUS
ACCESS ROAD SHALL COMPLY WITH THE REQUIREMENTS OF
SECTION 503.2 AND SHALL EXTEND TO WITHIN 100' OF ALL PORTIONS
OF THE EXTERIOR WALLS OF THE BUILDING AS MEASURED BY AN
APPROVED ROUTE AROUND THE EXTERIOR OF THE BUILDING.
3.) EITHER PARKING LOT PAVEMENT WILL NEED TO BE INSTALLED
BEFORE VERTICAL CONSTRUCTION OR THE ACCESS DRIVE ON THE
SOUTH AND SE ENCOMPASS DRIVE WILL NEED TO BE INSTALLED
BEFORE VERTICAL CONSTRUCTION WILL BE ALLOWED.
4.) ANY FUTURE EXPANSION OF THE BUILDING IS SUBJECT TO REVIEW
AND APPROVAL OF AN AMENDED SITE PLAN.
24'9'24'03/05/2019 SITE PLAN REVIEW - 3RD PJJ
03/14/2019 SITE PLAN REVIEW - 4TH PJJ
PROPOSED INGRESS/EGRESS EASEMENT
PER ENCOMPASS DRIVE SITE PLANS
OFFICE
BUILDING
(3,959 1ST FLOOR SF)
(6,642 TOTAL SF)
FFE=1038.50
Proposed 24'
Access Easement
Proposed 24'
Access Easement
Proposed 20' Private
Sanitary Sewer Easement
FUTURE TRAIL
(BY OTHERS)
cp MAGNAIL
7
1036.39 Sanitary Sewer EasementPer The Shops AtKettlestone North Plat 1CB
T/C=1038.45
I=
CB
T/C=1038.40
I=
STM MH
R=1038.54
I=
CB
T/C=1038.41
I=
CB
T/C=1038.31
I=
SAN MH
R=1032.77
I=1018.12 8" PVC NE
1018.15 8" PVC SW
1018.64 8" PVC N
SAN MH
R=1033.11
I=1018.35 W
1018.35 E
10
10' PUE
BK2019 PG1138
10' PUE
BK2019 PG1138
15' Public Water Main Easement
BK2019 PG1137
8" WATERMAIN 8" WATERMAIN12" STORM SEWER
24
"
S
T
O
R
M
S
E
W
E
R24" STORM SEWER24" STORMSEWER24" STORM SEWER30" STORM SEWER8" WATER
SERVICE STUB30" STORM SEWER30" STO
R
M
S
E
W
E
R
EXISTING 8" WATERMAINEXISTING 15"
STORM SEWER
20' Private Sanitary Sewer Easement
BK2019 PG1139
20
EXISTING 18"
STORM SEWER
FUTURE TRAIL
(BY OTHERS)
FUTURE CATCH BASIN
R=1033.84
I=1029.43P-01I=1030.89 (P-02)
I=1030.64 (P-01)
R=1035.25
A-01
P-02
P-03
I=1031.98 (P-02)
I=1032.23 (P-03)
R=1037.47
A-02
SP-3
SP-2
I=1023.48 (SP-3)
I=1023.28 (SP-2)
R=1039.14
S-2
I=1019.24 (SP-2)
I=1019.04 (SP-1)
R=1036.36
S-1
SP-1
I=1033.05 (P-04)
I=1032.80 (P-03)
R=1038.44
A-03
P-04
I=1027.86 (SP-3)
R=1040.69
S-3
SP-4
STORM DRAIN SCHEDULE
STRUCTURE
NO.
A-01
A-02
A-03
STRUCTURE
TYPE
SW-501
SW-501
NYLOPLAST DRAIN BASIN
STRUCTURE
SIZE (In)
36 x 24
36 x 24
12 Ø
STRUCTURE
MATERIAL
RC
RC
PVC
CASTING
SW-603 TYPE R
SW-603 TYPE R
SOLID COVER
PAY HEIGHT
LN FT
4.61
5.49
5.64
* TOP OF CASTING
ELEVATION
1035.25
1037.47
1038.44
INVERT
ELEVATION
1030.64
1031.98
1032.80
OUTLET
PIPE
P-01
P-02
P-03
STORM DRAIN PIPE SCHEDULE
PIPE
NO.
P-01
P-02
P-03
P-04
DRAIN
FROM
A-01
A-02
A-03
CAP
INLET
ELEVATION
1030.64
1031.98
1032.80
1033.67
DRAIN
TO
A-3C
A-01
A-02
A-03
OUTLET
ELEVATION
1029.93
1030.89
1032.23
1033.05
PIPE
SIZE (IN)
12
12
12
12
MATERIAL
RCP
RCP
HDPE
HDPE
PIPE
CLASS
5
5
SCH. 40
SCH. 40
PIPE
GRADE
1.50%
1.50%
1.00%
1.00%
PIPE
LENGTH (FT)
48
72
57
62
SANITARY SEWER STRUCTURE SCHEDULE
STRUCTURE
NO.
S-1
S-2
S-3
STRUCTURE
TYPE
SW-301
SW-301
SW-301
STRUCTURE
SIZE (In)
48 Ø
48 Ø
48 Ø
STRUCTURE
MATERIAL
RC
RC
RC
CASTING
SW-601 TYPE A GRATE
SW-601 TYPE A GRATE
SW-601 TYPE A GRATE
PAY HEIGHT
LN FT
17.31
15.85
12.83
TOP OF CASTING
ELEVATION
1036.36
1039.14
1040.69
INVERT
ELEVATION
1019.04
1023.28
1027.86
PIPE
NO.
SP-1
SP-2
SP-3
SANITARY SEWER PIPE SCHEDULE
PIPE
NO.
SP-1
SP-2
SP-3
SP-4
DRAIN
FROM
S-1
S-2
S-3
CAP
INLET
ELEVATION
1019.04
1023.28
1027.86
1030.00
DRAIN
TO
EXISTING SANITARY MANHOLE
S-1
S-2
OUTLET
ELEVATION
1018.62
1019.24
1023.48
1024.40
PIPE
SIZE
8"
8"
8"
6"
PIPE
CLASS
SDR-26
SDR-26
SDR-26
SDR-26
PIPE
GRADE
2.00%
2.00%
2.00%
6.45%
PIPE
LENGTH (FT)
21
202
219
87
22652 C3-SITE
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
SITE UTILITY PLAN
C3-20
-
PJJ
RJA
DAJ
SITE PLAN 02/01/19
19-22652
C3-20 SITE UTILITY PLAN
---- ---- C3-20
0
SCALE IN FEET
30 60 90
UNNAMED ACCESS DRIVE SE ENCOMPASS DRIVESE PARKVIEW CROSSING DRIVEB.M. ELEVATION=1032.32
BURY BOLT ON FIRE HYDRANT,
EAST SIDE OF GRAND PRARIE PARKWAY,
790' NORTH OF S.E. ESKER RIDGE DRIVE
PRELIMINARY NOT FOR CONSTRUCTION PRELIMINARY NOT FOR CONSTRUCTIONFUTURE
DEVELOPMENT
(BY OTHERS)
* TOP OF CASTING ELEVATIONS OF CURB STYLE CATCH BASINS REPRESENTS TOP OF CURB BOX AND NOT GUTTER ELEVATIONS
UTILITY LEGEND
EXISTING PROPOSED
STORM DRAIN
SANITARY SEWER
SANITARY SEWER FORCEMAIN
WATER MAIN
GAS
OVERHEAD ELECTRIC
UNDERGROUND ELECTRIC
UNDERGROUND TELEPHONE
UNDERGROUND TV
OVERHEAD UTILITY
UNDERGROUND UTILITY
FIBER OPTIC
NOTES:
1.) CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES.
2.) ALL UTILITIES THAT ARE TO BE CONSTRUCTED TO 5' OUTSIDE OF BUILDING ARE TO BE CONNECTED
TO BUILDING BY MECHANICAL CONTRACTOR.
3.) ENSURE 18" VERTICAL SEPARATION BETWEEN ALL PROPOSED & EXISTING WATER, STORM &
SANITARY UTILITIES.
4.) WATER SERVICE MUST HAVE 5.5 FT MINIMUM COVER.
5.) GAS SERVICE AND METER TO BE INSTALLED AND SET BY THE CITY OF WAUKEE.
PROPOSED TRANSFORMER
(VERIFY LOCATION W/UTILITY COMPANY)
CONSTRUCT:
4 LF 2" WATER SERVICE
4 LF 6" FIRE SERVICE
(CONNECT TO EXISTING SERVICE STUBS)
(STUB 5' FROM BUILDING, CAP END)
(CONNECTION TO THE BUILDING BY OTHERS)
CONSTRUCT 4 LF 6" ROOF
DRAIN LEADER @ 1.0% MIN.
(TYP. OF 4)(SEE DETAIL)
STUB 6" SANITARY SEWER
5' FROM BUILDING, CAP END
I=1027.63
CONNECT P-01 TO FUTURE CATCH BASIN
(VERIFY DEPTH & LOCATION)
CONNECT SP-1 TO EXISTING
SANITARY MANHOLE
WAUKEE IOWA
02/19/2019 SITE PLAN REVIEW - 2ND PJJ
LOT 2
THE SHOPS AT
KETTLESTONE
NORTH PLAT 6
FIRE RISER ROOOM
(REFER TO MECHANICAL PLANS)
GAS METER LOCATION
CRITICAL CROSSING
6" SANITARY SERVICE
TOP=1030.00
12" STORM SEWER
BOTTOM=1032.66
03/05/2019 SITE PLAN REVIEW - 3RD PJJ
CRITICAL CROSSING
8" SANITARY SEWER
TOP=1019.41
BOTTOM=1018.75
15" STORM SEWER
TOP=1027.33
BOTTOM=1026.08
CONSTRUCT SUBDRAIN
@ 1.0% MIN.
(MAINTAIN 2' COVER MIN.)
03/14/2019 SITE PLAN REVIEW - 4TH PJJ
F&i: 8"x6" WYE
OFFICE
BUILDING
(3,959 1ST FLOOR SF)
(6,642 TOTAL SF)
FFE=1038.50
Proposed 24'
Access Easement
Proposed 24'
Access Easement
Proposed 20' Private
Sanitary Sewer Easement
FUTURE TRAIL
(BY OTHERS)Sanitary Sewer EasementPer The Shops AtKettlestone North Plat 1SAN MH
R=1032.77
I=1018.12 8" PVC NE
1018.15 8" PVC SW
1018.64 8" PVC N
SAN MH
R=1033.11
I=1018.35 W
1018.35 E
10
10' PUE
BK2019 PG1138
10' PUE
BK2019 PG1138
15' Public Water Main Easement
BK2019 PG1137
20' Private Sanitary Sewer Easement
BK2019 PG1139
20
FUTURE TRAIL
(BY OTHERS)
22652 C3-SITE
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
HYDRANT
COVERAGE MAP
C3-21
-
PJJ
RJA
DAJ
SITE PLAN 02/01/19
19-22652
C3-21 HYDRANT COVERAGE MAP
---- ---- C3-21
0
SCALE IN FEET
30 60 90
UNNAMED ACCESS DRIVE SE ENCOMPASS DRIVESE PARKVIEW CROSSING DRIVEB.M. ELEVATION=1032.32
BURY BOLT ON FIRE HYDRANT,
EAST SIDE OF GRAND PRARIE PARKWAY,
790' NORTH OF S.E. ESKER RIDGE DRIVE
PRELIMINARY NOT FOR CONSTRUCTION PRELIMINARY NOT FOR CONSTRUCTIONHYDRANT COVERAGE LEGEND
EXISTING HYDRANT
PROPOSED HYDRANT
R150'
R150'
WAUKEE IOWA
02/19/2019 SITE PLAN REVIEW - 2ND PJJ
LOT 2
THE SHOPS AT
KETTLESTONE
NORTH PLAT 6
03/05/2019 SITE PLAN REVIEW - 3RD PJJ
03/14/2019 SITE PLAN REVIEW - 4TH PJJ
10
10' PUE
BK2019 PG1138
10' PUE
BK2019 PG1138
15' Public Water Main Easement
BK2019 PG1137
20' Private Sanitary Sewer Easement
BK2019 PG1139
20
OFFICE
BUILDING
(3,959 1ST FLOOR SF)
(6,642 TOTAL SF)
FFE=1038.50
Proposed 24'
Access Easement
Proposed 24'
Access Easement
Proposed 20' Private
Sanitary Sewer Easement
FUTURE TRAIL
(BY OTHERS)
1
0
3
91038 103710361035103810401040103810391040103910381037 103710371
0
3
6
1
0
3
5
1
0
3
1
1
0
3
2
10
3
3
1
0
3
7
1
0
3
8
1
0
3
9
1
0
4
0
10411042103810371
0
3
6
1
0
3
5
1037103510341033103110381039.301039.51
1039.47
1039.43
1039.31
1039.30
1
0
3
9
.
9
7 1039.771039.841039.90TAPER1039.54MATCH1039.211039.301039.40TAPER1039.001039.091038.951039.041038.851038.941038.231038.251038.101037.941037.421037.841037.43
1037.841
0
3
7
.
9
4
1037.901038.001037.901035.031034.801034.911035.151035.181034.86E.O.F.10
3
5
.
0
9
103
5
.
0
7
1035.021034.931037.561037.471037.561037.56EOF1037.471038.061037.961037.861038.221
0
3
8
.
3
9
1038.171038.111038.011037.911037.89CROWN 1035.21CROWN1035.001039.41MATCH1039.14MATCH1038.84MATCH1038.91MATCH1034.99MATCH1034.26MATCH1034.18MATCH???MATCH???MATCH1038.001038.001038.171035.271038.591038.381038.291037.68103710381037
10381039
1039
10401040103810391040104010391041104110381038.281038.50-4.8%-20.2%-13.5%-2.
2
%
1038.50
1038.401038.501038.401037.82MATCH1037.82MATCH1037.75MATCH1037.75MATCH1038.50
1038.501039.701038.891038.141036.281037.13100 YR1034.831
0
0
Y
R
-1.8%-2.2
%
-3.9%-4.5%-2.7%
-30.4%
-31.3%
-27.4%
-27.2%-2.4%-0.7%1038.551038.461038.261038.171037.871037.781
0
3
7
.
9
51037.861038.221038.201
0
3
8
.
4
0
1
0
3
8
.
5
0
1038.501038.401038.411038.321038.021038.141
0
3
8
.
2
5
1038.341038.091
0
3
7
.
7
0 1038.50-4.9%-1.3%-1.9%-1.0%-7.5%-1.5%1038-1.5%
-1.5%
-1.5%
-1.5%
-1.5%-7.5%-1.3%-4.9%1038.5022652 C4-GRADE
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
SITE GRADING PLAN
C4-10
-
PJJ
RJA
DAJ
SITE PLAN 02/01/19
19-22652
C4-10 SITE GRADING PLAN
---- ---- C4-10
0
SCALE IN FEET
20 40 60
UNNAMED ACCESS DRIVE SE ENCOMPASS DRIVEB.M. ELEVATION=1032.32
BURY BOLT ON FIRE HYDRANT,
EAST SIDE OF GRAND PRARIE PARKWAY,
790' NORTH OF S.E. ESKER RIDGE DRIVE
PRELIMINARY NOT FOR CONSTRUCTION PRELIMINARY NOT FOR CONSTRUCTIONSE PARKVIEW CROSSING DRIVEGRADING LEGEND
FUTURE CONTOUR (BY OTHERS) (MINOR INTERVAL)
FUTURE CONTOUR (BY OTHERS) (MAJOR INTERVAL)
EXISTING CONTOUR (MINOR INTERVAL)
EXISTING CONTOUR (MAJOR INTERVAL)
PROPOSED CONTOUR (MINOR INTERVAL)
PROPOSED CONTOUR (MAJOR INTERVAL)
PROPOSED SPOT ELEVATION
PROPOSED TOP BACK OF CURB SPOT ELEVATION
PROPOSED EMERGENCY OVERFLOW SPOT ELEVATION
PROPOSED 100 YEAR SPOT ELEVATION
SURFACE GRADE / DIRECTION
GENERAL GRADING NOTES
1.) SEE GEOTECHNICAL REPORT 08185138-01 PREPARED BY TERRACON FOR CONSTRUCTION
DIRECTIONS.
2.) PROPOSED CONTOURS SHOW FINISHED GRADE ELEVATIONS. BUILDING PAD AND PAVEMENT HOLD
DOWNS ARE NOT INCLUDED.
101
100
101
100
101
100
XXX.XXXXX.XX-X.X%
INSET A
SCALE 1"=10'
INSET A
EXISTING PROPERTY LINE, TYP.EXISTING CONTOUR, TYP.
PROPOSED CONTOUR, TYP.
FUTURE CONTOUR, TYP.
(BY OTHERS)
WAUKEE IOWA
02/19/2019 SITE PLAN REVIEW - 2ND PJJ
LOT 2
THE SHOPS AT
KETTLESTONE
NORTH PLAT 6
03/05/2019 SITE PLAN REVIEW - 3RD PJJ
XXX.XXE.O.F.XXX.XX100 YRGRADE 18" BERM ABOVE
TOP BACK OF CURB
03/14/2019 SITE PLAN REVIEW - 4TH PJJ
FUTURE TRAIL
(BY OTHERS)
OFFICE
BUILDING
(3,959 1ST FLOOR SF)
(6,642 TOTAL SF)
FFE=1038.50
Proposed 24'
Access Easement
Proposed 24'
Access Easement
Proposed 20' Private
Sanitary Sewer Easement
FUTURE TRAIL
(BY OTHERS)
ST2 - (5)
SM2 - (2)
JF - (4)
SM2 - (5)
JF - (4)
SM2 - (5)
JF - (4)
FS - (2)
SH - (1)
FS - (2)
SH - (1)
FS - (1)
(5) - SO
CK - (5)
PL2 - (6)
PS3 - (5)
RC - (2)
HH - (3)
SM2 - (1)
VC - (3)
SM2 - (2)
SGL - (4)
SM2 - (2)
VC - (3)
RC - (3)
ST - (2)
HL - (1)
CK - (5)
ST - (1)
HL - (3)
(2) - ST
(3) - CA2
(4) - ST
(1) - CA2
(2) - RC
(2) - SM2
(2) - HH
1
2
(1) - VC
(4) - HH
SGL - (5)
SC - (1)
CK - (11)
QR - (4)
SC - (6)
TREES CODE QTY COMMON / BOTANICAL NAME SIZE ROOT REMARKS
FS 5 Fat Albert Colorado Blue Spruce 6` Ht B & B
Picea pungens glauca `Fat Albert`
QR 4 Regal Prince English Oak 12` HT MIN B & B
Quercus robur `Regal Prince`
SC 7 Spring Snow Crabapple 6` HT MIN B & B
Malus x `Spring Snow`
SH 2 Skyline Honey Locust 6` HT MIN B & B
Gleditsia triacanthos `Skyline`
SO 5 Swamp White Oak 12` HT MIN B & B
Quercus bicolor
SHRUBS CODE QTY COMMON / BOTANICAL NAME SIZE ROOT REMARKS
CA2 4 Artic Fire Dogwood 24" HT MIN CONT
Cornus sericea `Artic Fire`
HH 9 Oakleaf Hydrangea 24" HT MIN CONT
Hydrangea quercifolia `Harmony`
HL 4 Oakleaf Hydrangea 24" HT MIN CONT
Hydrangea quercifolia `Little Honey`
JF 12 Sea Green Juniper 18" HT MIN CONT
Juniperus chinensis `Sea Green`
PL2 6 Dwarf Ninebark 18" HT MIN CONT
Physocarpus opulifolius `Little Devil` TM
RC 7 Rose 18" HT MIN CONT
Rosa x `Carefree Wonder`
SGL 9 Gro-Low Fragrant Sumac 18" HT MIN CONT
Rhus aromatica `Gro-Low`
SM2 19 Dwarf Korean Lilac 24" HT MIN CONT
Syringa meyeri `Palibin`
ST2 5 Tinkerbelle Lilac 18" HT MIN CONT
Syringa patula `Tinkerbelle`
VC 8 Arrowwood Viburnum 18" HT MIN CONT
Viburnum dentatum `Compactum`
PERENNIALS CODE QTY COMMON / BOTANICAL NAME SIZE ROOT REMARKS
CK 21 Feather Reed Grass 12" HT MIN CONT
Calamagrostis x acutiflora `Karl Foerster`
PS3 5 Switch Grass 12" HT MIN CONT
Panicum virgatum `Shenandoah`
ST 9 Prairie Dropseed 12" HT MIN CONT
Sporobolus heterolepis `Tara`
GROUND COVERS CODE QTY COMMON / BOTANICAL NAME SIZE ROOT REMARKS
SOD 11,616 SOD SOD SF
BLUEGRASS SOD
PLANT SCHEDULE
REFERENCE NOTES SCHEDULE
SYMBOL DESCRIPTION QTY DETAIL
STEEL EDGING / COLOR : BLACK 503 lf
2" CLEAN RIVER GRAVEL 29.75 cy
1
2
REFERENCE NOTES SCHEDULE
22652 C5-LAND
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
SITE PLANTING &
RESTORATION PLAN
C5-10
-
PJJ
RJA
DAJ
SITE PLAN 02/01/19
19-22652
C5-10 SITE PLANTING & RESTORATION PLAN
---- ---- C5-10
0
SCALE IN FEET
20 40 60
UNNAMED ACCESS DRIVE SE ENCOMPASS DRIVEB.M. ELEVATION=1032.32
BURY BOLT ON FIRE HYDRANT,
EAST SIDE OF GRAND PRARIE PARKWAY,
790' NORTH OF S.E. ESKER RIDGE DRIVE
PRELIMINARY NOT FOR CONSTRUCTION PRELIMINARY NOT FOR CONSTRUCTIONSE PARKVIEW CROSSING DRIVEAS REQUIRED IN THE CITY OF WAUKEE, IOWA ZONING CODE.
LOT DATA:
TOTAL LOT AREA = 26,136 SF / 0.60 AC
K-OF / PD-1 = LOT'S ZONING DISTRICT
179 LF = LENGTH OF SETBACK BETWEEN R/W AND PARKING
REQUIRED OPEN SPACE
(CODE: 25% OF TOTAL LOT AREA, 26,136 x 25% = 6,534SF REQUIRED)
.17 AC / 7,405 SF PROVIDED
10 OVERSTORY TREES REQUIRED, 11 PROVIDED
(CODE: REQ. OPEN SPACE / 6,534 SF / 1000 x 1.5 = 9.8 OR 10 TREES)
3 OVERSTORY TREES = NUMBER OF OVERSTORY TREES FOR PARKING SETBACK REQ.
7 UNDERSTORY TREES REQUIRED, 7 PROVIDED
(CODE: REQ. OPEN SPACE / 6,534 SF / 1000 X 0.5 = 6.5 OR 7 TREES)
14 SHRUBS REQUIRED, 81 PROVIDED
(CODE: REQ. OPEN SPACE / 6,534 SF / 1000 x 2 = 13.06 OR 14 SHRUBS)
CITY LANDSCAPE REQUIREMENTS BUFFER BETWEEN PARKING AND R/W (179 LF)
2 OVERSTORY TREES PER 50 LF = 8 REQUIRED,
6 OVERSTORY, 3 EVERGREEN AND 6 UNDERSTORY
PROVIDED
8 SHRUBS PER 50 LF = 29 REQUIRED, 29 PROVIDED
STREET TREES
1 OVERSTORY TREE PER 40 LF (150 LF)
4 REQUIRED, 4 PROVIDED.
OTHER REQUIREMENTS:
* 10 OF REQ. TREES MUST BE OVERSTORY
(CODE: 50% OF REQ. TREES SHALL BE OVERSTORY),
11 OVERSTORY TREES PROVIDED
* 5 OF REQ. TREES MUST BE EVERGREEN
(CODE: 25% OF REQ. TREES SHALL BE EVERGREEN),
5 EVERGREEN TREES PROVIDED.
TOTAL PLANTS SHOWN ON PLAN
11 OVERSTORY TREES
5 EVERGREEN TREES
7 UNDERSTORY TREES
83 SHRUBS
35 PERENNIALS & GRASSES
WAUKEE IOWA
02/19/2019 SITE PLAN REVIEW - 2ND PJJ
LOT 2
THE SHOPS AT
KETTLESTONE
NORTH PLAT 6
03/05/2019 SITE PLAN REVIEW - 3RD PJJ
03/14/2019 SITE PLAN REVIEW - 4TH PJJ
22652 C5-LAND
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
PLANTING &
RESTORATION PLAN
C5-20
-
PJJ
RJA
DAJ
SITE PLAN 02/01/19
19-22652
C5-20 PLANTING & RESTORATION PLAN
---- ---- C5-20
B.M. ELEVATION=1032.32
BURY BOLT ON FIRE HYDRANT,
EAST SIDE OF GRAND PRARIE PARKWAY,
790' NORTH OF S.E. ESKER RIDGE DRIVE
PRELIMINARY NOT FOR CONSTRUCTION PRELIMINARY NOT FOR CONSTRUCTIONGENERAL PLANTING NOTES
LANDSCAPE EDGING DETAIL
SCALE: 1" = 1'-0"
MULCH - PER PLANS & NOTES
PLANTING BED - SOIL PREPARATION PER PLANS
& NOTES
LAWN OR GROUND COVER
FINISH GRADE
LANDSCAPE EDGING AND STAKING - PER PLANS
& NOTES
SUBGRADE - PER PLANS & NOTES
DECIDUOUS TREE PLANTING DETAIL
SCALE: 1" = 1'-0"
TOP OF ROOTBALL TO BE SET ABOVE GRADE 3"
CUT AND REMOVE AT MINIMUM THE TOP HALF OF
WIRE BASKETS, BURLAP AND/OR TWINE AND
REMOVE FROM THE PLANTING PIT. AVOID CUTTING
OR SCARING ROOTS. ANY ROOTS THAT ARE SCARED
OR BROKEN DURING PLANTING SHOULD BE CUT
CLEAN AT 90 DEGREES
BACKFILL PLANTING PIT PER TREE PLANTING
SPECIFICATIONS WHEN PROVIDED, OR WITH NATIVE
SOIL-EXCEPT WHEN IN HEAVY CLAY, MIX AMENDED
TOPSOIL FROM A LOCAL SOURCE WITH NATIVE SOIL
EXCAVATE PLANTING PIT TO A DEPTH EQUAL TO THE
DEPTH OF THE ROOTBALL MINUS 3" AND A MINIMUM
TWICE THE DIAMETER OF THE ROOTBALL
PLACE ROOTBALL ON UNDISTURBED SOIL AND
ENSURE TRUNK OF TREES IS PLUMB
3"LAYER OF SHREDDED HARDWOOD MULCH
MOUNDED AT EDGE TO FORM A SHALLOW SAUCER -
DO NOT PLACE MULCH DIRECTLY ON TREE TRUNK,
LEAVE A MIN. 3" RING AROUND CROWN
ROOTBALL DIA
2X ROOTBALL DIA
DEPTH OF
ROOTBALL
NEVER CUT PRIMARY LEADER
PRUNE ALL BROKEN, DAMAGED, OR RUBBING LIMBS
AND BRANCHES IMMEDIATELY AFTER PLANTING -
ALL PRUNING CUTS CLEAN AT 90 DEGREES
*NOTE: DO NOT
STAKE TREES
UNLESS INDICATED.
FINISH GRADE
CONIFER / EVERGREEN TREE PLANTING DETAIL
SCALE: 1" = 1'-0"
TIE NYLON STRAP AROUND TRUNK AS SHOWN
CUT AND REMOVE AT MINIMUM THE TOP HALF OF
WIRE BASKETS, BURLAP AND/OR TWINE AND REMOVE
FROM THE PLANTING PIT. AVOID CUTTING OR
SCARING ROOTS. ANY ROOTS THAT ARE SCARED OR
BROKEN DURING PLANTING SHOULD BE CUT CLEAN
AT 90 DEGREES
BACKFILL PLANTING PIT PER TREE PLANTING
SPECIFICATIONS WHEN PROVIDED, OR WITH NATIVE
SOIL-EXCEPT WHEN IN HEAVY CLAY, MIX AMENDED
TOPSOIL FROM A LOCAL SOURCE WITH NATIVE SOIL
EXCAVATE PLANTING PIT TO A DEPTH EQUAL TO THE
DEPTH OF THE ROOTBALL MINUS 3" AND A MINIMUM
TWICE THE DIAMETER OF THE ROOTBALL
PLACE ROOTBALL ON UNDISTURBED SOIL AND
ENSURE TRUNK OF TREES IS PLUMB
3" LAYER OF SHREDDED HARDWOOD MULCH
MOUNDED AT EDGE TO FORM A SHALLOW SAUCER -
DO NOT PLACE MULCH DIRECTLY ON TREE TRUNK,
LEAVE A MIN. 3" RING AROUND CROWN
ROOTBALL DIA
2X ROOTBALL DIA
DEPTH OF
ROOTBALL
NEVER CUT PRIMARY LEADER
PRUNE ALL BROKEN, DAMAGED, OR RUBBING LIMBS
AND BRANCHES IMMEDIATELY AFTER PLANTING - ALL
PRUNING CUTS CLEAN AT 90 DEGREES
FINISH GRADE
MULTI STEM PLANTING DETAIL
SCALE: 1" = 1'-0"
TOP OF ROOTBALL TO BE SET SLIGHTLY ABOVE
GRADE 3"
CUT AND REMOVE AT MINIMUM THE TOP HALF OF
WIRE BASKETS, BURLAP AND/OR TWINE AND REMOVE
FROM THE PLANTING PIT. AVOID CUTTING OR
SCARING ROOTS. ANY ROOTS THAT ARE SCARED OR
BROKEN DURING PLANTING SHOULD BE CUT CLEAN
AT 90 DEGREES
BACKFILL PLANTING PIT PER TREE PLANTING
SPECIFICATIONS WHEN PROVIDED, OR WITH NATIVE
SOIL-EXCEPT WHEN IN HEAVY CLAY, MIX AMENDED
TOPSOIL FROM A LOCAL SOURCE WITH NATIVE SOIL
EXCAVATE PLANTING PIT TO A DEPTH EQUAL TO THE
DEPTH OF THE ROOTBALL MINUS 3" AND A MINIMUM
TWICE THE DIAMETER OF THE ROOTBALL
PLACE ROOTBALL ON UNDISTURBED SOIL AND
ENSURE TRUNK OF TREES IS PLUMB
3" LAYER OF SHREDDED HARDWOOD MULCH
MOUNDED AT EDGE TO FORM A SHALLOW SAUCER -
DO NOT PLACE MULCH DIRECTLY ON TREE TRUNK,
LEAVE A MIN. 3" RING AROUND CROWN
ROOTBALL DIA.
2X ROOTBALL DIA.
DEPTH OF
ROOTBALL
NEVER CUT PRIMARY LEADERS - 3 LARGEST
DIAMETER STEMS
PRUNE ALL BROKEN, DAMAGED, OR RUBBING LIMBS
AND BRANCHES IMMEDIATELY AFTER PLANTING - ALL
PRUNING CUTS CLEAN AT 90 DEGREES
NOTE:
1. DO NOT STAKE
TREES UNLESS
INDICATED.
2. THOROUGHLY
WATER-IN ALL
TREES IMMEDIATELY
AFTER PLANTING
AND ENSURE NO
UNDESIRABLE
SETTLING OCCURS -
TREE STAYS PLUMB
FINISH GRADE
SHRUB PLANTING DETAIL
SCALE: 1" = 1'-0"
3" LAYER OF MULCH, PER PLANS & NOTES
BACKFILL PLANTING PIT PER SHRUB PLANTING
SPECIFICATIONS WHEN PROVIDED, OR WITH NATIVE
SOIL-EXCEPT WHEN IN HEAVY CLAY, MIX AMENDED
TOPSOIL FROM A LOCAL SOURCE WITH NATIVE SOIL
EXCAVATE PLANTING PIT TO A DEPTH EQUAL TO THE
DEPTH OF THE ROOTBALL / CONTAINER MINUS 3" AND
A MINIMUM TWICE THE DIAMETER OF THE ROOTBALL
/ CONTAINER - TILL ALL PLANTING BEDS TO A
MINIMUM DEPTH OF 6" THROUGHT
PLACE ROOTBALL ON UNDISTURBED SOIL AND
ENSURE PLANT IS PLUMB
ALL PLANTS TO BE INSTALLED SO THAT THE TOP OF
THE CROWN OF THE PLANT IS SLIGHTLY ABOVE
FINISH GRADE 3"
ROOTBALL DIA
2X ROOTBALL DIA
DEPTH OF
ROOTBALL
FINISH GRADE
CUT AND REMOVE AT MINIMUM THE TOP HALF OF
WIRE BASKETS, BURLAP AND/OR TWINE, OR ENTIRE
CONTAINER, AND REMOVE FROM THE PLANTING PIT,
SCARIFY ROOTS FOR ALL CONTAINERIZED PLANTS 5
GALLONS FOR SMALLER
CONTAINER DIA
2X CONTAINER DIA
PLAN
PERENNIAL PLANTING DETAIL
SCALE: 1" = 1'-0"
EDGE OF PLANTING BED - PER PLANS &
NOTES
PLANT UNDER DRIP LINE OF LIMBED UP
SHRUBS AND TREES
STAGGER SPACING WHERE POSSIBLE
EDGE OF STRUCTURE OR PAVING
PLANT PERIMETER AT SPECIFIED SPACING
FINISH GRADE
UNLESS OTHERWISE NOTED, PLANT UP TO
EXISTING DRIP LINE OF ADJACENT SHRUBS
SECTION
3" LAYER OF MULCH PER MATERIALS SCHEDULE, OR
AS NOTED ON PLAN
TILL ALL PLANT BEDS TO A MINIMUM DEPTH OF 6" AND
BACKFILL PER SPECIFICATIONS, WHEN PROVIDED - IN
AREAS WITH HEAVY CLAY OR ROCKY SOILS AMEND
WITH AMENDED PLANTING SOIL FROM A LOCAL
SOURCE
ALL PLANTS TO BE INSTALLED SO THAT THE TOP OF
THE CROWN OF THE PLANT IS SLIGHTLY ABOVE
FINISH GRADE 3"
CUT AND REMOVE THE ENTIRE CONTAINER AND
SCARIFY, AS NECESSARY, ROOTS FOR ALL
CONTAINERIZED PLANTS 5 GALLONS FOR SMALLERBED EDGE PER PLANS
PLACE ROOTBALL ON UNDISTURBED SOIL AND
ENSURE PLANT IS PLUMB
PLAN
PERENNIAL PLANTING DETAIL
SCALE: 1" = 1'-0"
FINISH GRADE
SECTION
BED EDGE
PER PLANS
SYMMETRICAL
SPACING
1/2 SPECIFIED
PLANT SPACING TIE NYLON STRAPPING AROUND TRUNK AS SHOWN
1/2" WIDE NYLON STRAPPING - COLOR TO BE
APPROVED BY LANDSCAPE ARCHITECT
ORANGE CAUTION
MARKERS
#4 REBAR, 18" LONG -
DRIVE TOP STAKE
BELOW GRADE
STAKING DIAGRAM
TREES 8'+TREES 6'-8'
TOP OF ROOTBALL TO BE SET ABOVE GRADE 3"
1/2" WIDE NYLON STRAPPING - COLOR TO BE
APPROVED BY LANDSCAPE ARCHITECT
*NOTE: DO NOT
STAKE TREES
UNLESS INDICATED.
HARDWOOD STAKES
2"X2"X8' LONG -
INSTALL OUTSIDE
OF ROOTBALL AT 5'
MAX HT
STAKING DIAGRAM,
NO STAKING TREES
UNDER 6'
3" LAYER OF MULCH PER MATERIALS SCHEDULE, OR
AS NOTED ON PLAN
TILL ALL PLANT BEDS TO A MINIMUM DEPTH OF 6" AND
BACKFILL PER SPECIFICATIONS, WHEN PROVIDED - IN
AREAS WITH HEAVY CLAY OR ROCKY SOILS AMEND
WITH AMENDED PLANTING SOIL FROM A LOCAL
SOURCE
ALL PLANTS TO BE INSTALLED SO THAT THE TOP OF
THE CROWN OF THE PLANT IS SLIGHTLY ABOVE
FINISH GRADE 3"
CUT AND REMOVE THE ENTIRE CONTAINER AND
SCARIFY, AS NECESSARY, ROOTS FOR ALL
CONTAINERIZED PLANTS 5 GALLONS FOR SMALLER
PLACE ROOTBALL ON UNDISTURBED SOIL AND
ENSURE PLANT IS PLUMB
EDGE OF PLANTING BED / GROUND COVER AREA
INSTALL PLANTS PER PLANS AND PLANT LIST
SPACING - ALL PLANTS SHALL BE EQUALLY SPACED
TO ACHIEVE A SYMMETRICAL LAYOUT FOR BOTH
TRIANGULAR AND LINEAR PLANTING SCHEMES
1.COORDINATE LOCATION OF ALL UTILITIES (LINES, DUCTS, CONDUITS, SLEEVES, FOOTINGS, ETC.) WITH
LOCATIONS OF PROPOSED LANDSCAPE ELEMENTS (FENCE, FOOTINGS, TREE ROOTBALLS, ETC.).
CONTRACTOR SHALL REPORT ANY DISCREPANCIES TO OWNER'S REPRESENTATIVE PRIOR TO
CONTINUING WORK.
2.SAVE AND PROTECT ALL EXISTING TREES NOT NOTED TO BE REMOVED.
3.REMOVE ALL CONSTRUCTION DEBRIS AND MATERIALS INJURIOUS TO PLANT GROWTH FROM PLANTING
PITS AND BEDS PRIOR TO BACKFILLING WITH PLANTING MIX.
4.LAWN AREAS SHALL HAVE 8" MINIMUM DEPTH OF TOPSOIL. TOPSOIL SHALL BE COMPACTED TO 85%
MAXIMUM DENSITY AT OPTIMUM MOISTURE CONTENT. SHOULD MEET SUDAS STANDARD SECTION 2010.
5.REFER TO PLANTING DETAILS PLAN FOR AMENDED SOIL DEPTH IN PLANTING BEDS AND SURROUNDING
TREES. REFER TO SPECIFICATIONS FOR MIX TYPE.
6.FIELD STAKE PLANTINGS ACCORDING TO PLAN. OWNER'S REPRESENTATIVE SHALL APPROVE ALL
PLANT LOCATIONS PRIOR TO INSTALLATION. OWNER RESERVES THE RIGHT TO REVISE PLANTING
LAYOUT AT TIME OF INSTALLATION.
7.ALL PLANT MATERIALS SHALL BE TRUE TO THEIR SCIENTIFIC NAME AND SIZE AS INDICATED IN THE
PLANT SCHEDULE.
8.IF DISCREPANCIES EXIST BETWEEN THE NUMBER OF PLANTS DRAWN ON THE PLANTING PLAN AND THE
NUMBER OF PLANTS IN THE SCHEDULE, THE PLANTING PLAN SHALL GOVERN.
9.OWNER RESERVES THE RIGHT TO REVISE QUANTITIES TO SUIT BUDGET LIMITATIONS. CONTRACTOR'S
UNIT BID PRICES SHALL PREVAIL FOR ANY CHANGES IN QUANTITIES.
10.ALL SUBSTITUTIONS SHALL BE APPROVED IN WRITING BY THE CITY OF WAUKEE DEVELOPMENT
SERVICES DEPARTMENT.
11.ALL PLANT MATERIALS MUST CONFORM TO AMERICAN STANDARDS FOR NURSERY STOCK (A.N.S.I.),
LATEST EDITION PUBLISHED BY THE AMERICAN ASSOCIATION OF NURSERYMEN, WASHINGTON D.C.
LARGER SIZED PLANT MATERIALS OF THE SPECIES LISTED MAY BE USED IF THE STOCK CONFORMS TO
A.N.S.I.
12.ALL PLANT MATERIAL SHALL BE GUARANTEED TO BE IN A LIVE AND HEALTHY GROWING CONDITION FOR
ONE FULL GROWING SEASON (ONE YEAR) AFTER FINAL PROJECT ACCEPTANCE OR SHALL BE REPLACED
FREE OF CHARGE WITH THE SAME GRADE AND SPECIES. ALL TREES SHALL HAVE A STRONG CENTRAL
LEADER.
13.CONTRACTOR IS RESPONSIBLE FOR ALL DAMAGE DUE TO OPERATIONS. ANY AREAS THAT ARE
DISTURBED SHALL BE RESTORED TO ITS ORIGINAL CONDITION AT NO ADDITIONAL COST TO THE OWNER.
14.PLANTING BED EDGING - USE 3/4" x 6" PROFESSIONAL GRADE STEEL EDGING IN ALL AREAS WHERE
PLANTING BED MEETS LAWN AREAS OR WHERE INDICATED. USE 12" METAL SPIKES AS INSTRUCTED BY
MANUFACTURER.
15.PROVIDE SHREDDED HARDWOOD MULCH, NATURAL COLOR, SURROUNDING ALL PROPOSED TREES TO
A 3-INCH MINIMUM DEPTH AS SHOWN IN TREE PLANTING DETAIL. DO NOT USE AN UNDERLAYMENT SUCH
AS PLASTIC SHEET OR LANDSCAPE FABRIC. IF LOCATED WITHIN A ROCK MULCHED PLANT BED,
SUBSTITUTE THIS MULCH WITH THE MULCH CALLED FOR WITHIN THAT PLANT BED. APPLY
PRE-EMERGENT TO ALL PLANTING BEDS PRIOR TO MULCHING.
16.PROVIDE ROCK MULCH, 2" RIVER ROCK, IN ALL PLANTING TO A 2" MINIMUM DEPTH. USE A
PROFESSIONAL GRADE WOVEN WATER PERMEABLE LANDSCAPE FABRIC UNDERLAYMENT. DO NOT USE
PLASTIC SHEETING. APPLY PRE-EMERGENT TO ALL PLANTING BEDS PRIOR TO MULCHING.
17.TURF AREAS DISTURBED BY CONSTRUCTION SHALL BE SODDED IF NOT INDICATED ON PLANS AS
ANOTHER SURFACE. SOD SECTIONS SHALL BE NO SMALLER THAN 24" X 36" STAKED IN PLACE WITH
BIODEGRADABLE SOD STAKES WHEN SLOPE IS STEEPER THAN 5:1 OR WHEN CONDITIONS REQUIRE.
ALSO STAKE AT STORMWATER BASIN ON SLOPES AND BOTTOM TO PREVENT MOVEMENT.
18.IRRIGATION NOT REQUIRED
19.FOR PLANT, SHRUB, AND TREE LOCATIONS: CONTRACTOR IS PERMITTED TO USE DISCRETION AS
NECESSARY TO AVOID DRIVEWAYS, UTILITIES, OR OTHER CONFLICTS. THE TOTAL NUMBER OF PLANTS,
INCLUDING SHRUBS AND TREES SHALL MEET CITY CODE.
21.INDICATED QUANTITIES ARE ESTIMATES AND SHOULD BE CONFIRMED BY THE CONTRACTOR/BIDDER.
22.MINIMUM PLANT SIZES SHALL BE AS FOLLOW:
A.DECIDUOUS OVERSTORY TREES SHALL BE 8 FOOT MINIMUM HEIGHT
B.EVERGREEN OVERSTORY TREES SHALL BE 6 FOOT MINIMUM HEIGHT
C.DECIDUOUS UNDERSTORY TREES SHALL BE 6 FOOT MINIMUM HEIGHT
D.DECIDUOUS EVERGREEN SHRUBS SHALL BE 2 FOOT MINIMUM HEIGHT
WAUKEE IOWA
02/19/2019 SITE PLAN REVIEW - 2ND PJJ
LOT 2
THE SHOPS AT
KETTLESTONE
NORTH PLAT 6
03/05/2019 SITE PLAN REVIEW - 3RD PJJ
03/14/2019 SITE PLAN REVIEW - 4TH PJJ
10
10' PUE
BK2019 PG1138
10' PUE
BK2019 PG1138
15' Public Water Main Easement
BK2019 PG1137
8" WATERMAIN 8" WATERMAIN8" WATER
SERVICE STUB
EXISTING 8" WATERMAIN20' Private Sanitary Sewer Easement
BK2019 PG1139
20
OFFICE
BUILDING
(3,959 1ST FLOOR SF)
(6,642 TOTAL SF)
FFE=1038.50
Proposed 24'
Access Easement
Proposed 24'
Access Easement
Proposed 20' Private
Sanitary Sewer Easement
FUTURE TRAIL
(BY OTHERS)
BB
BB
AA
AA
AA
22652 C6-ELECTRICAL
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
PHOTOMETRICS
PLAN
C6-10
-
PJJ
RJA
DAJ
SITE PLAN 02/01/19
19-22652
C6-10 PHOTOMETRICS PLAN
---- ---- C6-10
0
SCALE IN FEET
20 40 60
UNNAMED ACCESS DRIVE SE ENCOMPASS DRIVESE PARKVIEW CROSSING DRIVEB.M. ELEVATION=1032.32
BURY BOLT ON FIRE HYDRANT,
EAST SIDE OF GRAND PRARIE PARKWAY,
790' NORTH OF S.E. ESKER RIDGE DRIVE
PRELIMINARY NOT FOR CONSTRUCTION PRELIMINARY NOT FOR CONSTRUCTIONFOOTCANDLE LEGEND
MANUFACTURER/MODEL NUMBER
LIGHT FIXTURE SCHEDULE
STYLETYPE LAMPS REMARKS
Provide light fixtures as shown on Fixture Schedule. Substitutions shall have prior approval by the Project Engineer before bid date. Being
listed as an acceptable Manufacturer in no way relieves the Contractors obligation to provide all equipment and features in accordance
with these specifications.
AA
(1) ALT4-P35-180L-4K-FGL-NFO
(1) #PTRS20-61120
HEAD(S)
SITE POLE SINGLE HEAD
POLE 20'-0" POLE
(1) 213W LED
KIM LIGHTING /
BB
#SLIM12N
WALL PACK RAB LIGHTING
(1) 12W LED
LIGHT POLE DETAIL
N.T.S.1
WAUKEE IOWA
02/19/2019 SITE PLAN REVIEW - 2ND PJJ
LOT 2
THE SHOPS AT
KETTLESTONE
NORTH PLAT 6
MOUNT @ 10'-0"
03/05/2019 SITE PLAN REVIEW - 3RD PJJ
03/14/2019 SITE PLAN REVIEW - 4TH PJJ
WH
OFFICE
RECEPTION
PLAN
NORTH 50' - 0"OFFICE OFFICE OFFICE
OFFICE OFFICE OFFICE OFFICE OFFICE
OPEN OFFICE CONFERENCE
9' - 2"40' - 10"UTILITY
KITCHEN
VEST
UP
SPRINKLER
3,404 sf Office Space
417 sf Core
95 sf Lobby
TRUE
NORTH
80' - 0"
11' - 0"69' - 0"
MEN
WOMEN
Phase 2
1,378 sf
TRASH
ENCLOSURE
PHASE 220' - 4"10' - 2"
WILKUS ARCHITECTS FIRST FLOOR
Page 01
KETTLEVIEW INSURANCE BUILDING
2019.02.01
SD - V4.1
MILLER, FIDLER & HINKE INSURANCE AGENCY
EXECUTIVE
OFFICE
EXECUTIVE
OFFICE
COLLABORATIVE
MEN
WOMEN
OFFICE
PERGOLA
STORAGE MECH40' - 10"39' - 5 1/4"26' - 1 1/8"
65' - 6 3/8"
ROOF OVER
FLOOR 1
(SHADED)
PHASE 2
PLAN
NORTH
TRUE
NORTH
Phase 2
1,378 sf
1,050 sf Office Space
1,068 sf Office Pergola
567 sf Core
WILKUS ARCHITECTS SECOND FLOOR
Page 02
KETTLEVIEW INSURANCE BUILDING
2019.02.01
MILLER, FIDLER & HINKE INSURANCE AGENCY
ROOF OVER
FLOOR 1
(SHADED)
ROOF OVER
FLOOR 2
(SHADED)
MECH AREA
(RAISED PARAPET WALLS)
PERGOLA
OVER FLOOR 2
(SHADED)
PHASE 2
ROOF
PLAN
NORTH
TRUE
NORTH
WILKUS ARCHITECTS ROOF PLAN
Page 03
KETTLEVIEW INSURANCE BUILDING
2019.02.01
MILLER, FIDLER & HINKE INSURANCE AGENCY
FINISH SLAB
0' -0"
SECOND LEVEL
14' -0"
LOW PARAPET
29' -0"
TOP ROOF
28' -0"
MID PARAPET
32' -0"
HIGH PARAPET
34' -0"
TRASH ENCLOSURE
20' - 4"
MECH AREA WITHIN
PARAPET, REFER TO ROOF
PLAN
WILKUS ARCHITECTS PLAN WEST ELEVATION
Page 04
KETTLEVIEW INSURANCE BUILDING
2019.02.01
MILLER, FIDLER & HINKE INSURANCE AGENCY
FINISH SLAB
0' -0"
SECOND LEVEL
14' -0"
LOW PARAPET
29' -0"
TOP ROOF
28' -0"
MID PARAPET
32' -0"
HIGH PARAPET
34' -0"
TRASH ENCLOSURE
10' - 2"7' - 6"MECH AREA WITHIN
PARAPET, REFER TO ROOF
PLAN
WILKUS ARCHITECTS PLAN SOUTH ELEVATION
Page 05
KETTLEVIEW INSURANCE BUILDING
2019.02.01
MILLER, FIDLER & HINKE INSURANCE AGENCY
FINISH SLAB
0' -0"
SECOND LEVEL
14' -0"
LOW PARAPET
29' -0"
TOP ROOF
28' -0"
MID PARAPET
32' -0"
HIGH PARAPET
34' -0"
MECH AREA WITHIN
PARAPET, REFER TO ROOF
PLAN
WILKUS ARCHITECTS PLAN EAST ELEVATION
Page 06
KETTLEVIEW INSURANCE BUILDING
2019.02.01
MILLER, FIDLER & HINKE INSURANCE AGENCY
FINISH SLAB
0' -0"
SECOND LEVEL
14' -0"
LOW PARAPET
29' -0"
TOP ROOF
28' -0"
MID PARAPET
32' -0"
HIGH PARAPET
34' -0"7' - 6"TRASH ENCLOSURE
10' - 2"
MECH AREA WITHIN
PARAPET, REFER TO ROOF
PLAN
WILKUS ARCHITECTS PLAN NORTH ELEVATION
Page 07
KETTLEVIEW INSURANCE BUILDING
2019.02.01
MILLER, FIDLER & HINKE INSURANCE AGENCY
WILKUS ARCHITECTS ISOMETRIC VIEW 1
Page 08
KETTLEVIEW INSURANCE BUILDING
2019.02.01
ANODIZED CAP FLASHING DARK BRONZE CAP FLASHING / FRAMES /
MISCELLANEOUS BREAK METAL
NICHIHA FIBER CEMENT
SIDING -REDWOOD
NICHIHA FIBER CEMENT
SIDING -GUNSMOKE
NICHIHA FIBER CEMENT
SIDING -MOTHER OF PEARL
NICHIHA FIBER CEMENT
SIDING -MOCHA
MILLER, FIDLER & HINKE INSURANCE AGENCY
MECH AREA WITHIN
PARAPET, REFER TO ROOF
PLAN
TRASH ENCLOSURE
WILKUS ARCHITECTS ISOMETRIC VIEW 2
Page 09
KETTLEVIEW INSURANCE BUILDING
2019.02.01
MILLER, FIDLER & HINKE INSURANCE AGENCY
WILKUS ARCHITECTS EXTERIOR
Page 10
KETTLEVIEW INSURANCE BUILDING
2019.02.01
MILLER, FIDLER & HINKE INSURANCE AGENCY
WILKUS ARCHITECTS EXTERIOR
Page 11
KETTLEVIEW INSURANCE BUILDING
2019.02.01
MILLER, FIDLER & HINKE INSURANCE AGENCY
WILKUS ARCHITECTS EXTERIOR
Page 12
KETTLEVIEW INSURANCE BUILDING
2019.02.01
MILLER, FIDLER & HINKE INSURANCE AGENCY
WILKUS ARCHITECTS EXTERIOR
Page 13
KETTLEVIEW INSURANCE BUILDING
2019.02.01
MILLER, FIDLER & HINKE INSURANCE AGENCY
10' - 0"2"8"2
A100
TYP.
4
A100
TYP.
2"20' - 0"2"
CL3' - 0"
CL 3' - 0"
CL CL CL CL4' - 0"4' - 8 3/4"4' - 0"
6 YARD TRASH
6' X 6' X 6'
6 YARD RECYCLING
6' X 6' X 6'
8" INTERIOR BOLLARDS
FILLED WITH CONCRETE
FINISHED
20' - 4"FINISHED10' - 2"A100
7
A100 8
A100
9
WALL CONSTRUCTION
NICHIHA SIDING SYSTEM
CMU WALL - SEE STRUCT
METAL CAP - MATCH
PARAPET FLASHING
FASTENER APPLIED TO
MASONRY BACK-UP WALL
NICHIHA CLIP, TYP
NICHIHA PANEL AS SCHED.
FACE FASTENER (HIDDEN)
NICHIHA SPACER
NICHIHA STARTER TRACK
"Z" DRIP FLASHING, COLOR
TO MATCH CAP FLASHING
2"SEE CIVIL
GRADE7' - 6"1' - 0"1' - 7"6"2"6"3"1"1-1/2" I.D. x 6" LONG STEEL PIPE
SLEEVE FLUSH WITH TOP OF PAVING -
PROVIDE AT CLOSED AND FULLY OPEN
POSITION, TYPICAL
CONCRETE PAVING
3/4" DIAMETER STEEL CANE BOLT
BOTTOM OF GATE
PIPE SLEEVE - WELD TO FRAME, GALVANIZED
FINISH
1/8" BAR IN "ZEE" PROFILE, 1"
WIDE - PROFILE TO ACCEPT CANE
BOLT - WELD TO FRAME
TRASH ENCLOSURE DOOR:
2" X 2" X 1/4" STEEL ANGLE STILES &
RAILS WITH 1-1/2", 22 GA GALVANIZED
CORRUGATED METAL DECKING "C"
PANELS & 1-1/4" x 1-1/4" x 3/16" STEEL
ANGLE BRACE
5"
NOTE: ALL EXPOSED METAL AND CMU
SURFACES FOR TRASH ENCLOSURE
TO BE PAINTED WITH EXTERIOR GRADE
EPOXY PAINT, COLOR TO MATCH
FLASHING, TYP.
NICHIHA PANEL TO MATCH BUILDING
9" DIA SCHEDULE 80 STEEL PIPE PIVOT -
PROVIDE STEEL SHIM BETWEEN PIVOT &
BOLLARD
8" DIA SCHEDULE 40 BOLLARD GROUT SOLID &
ROUND & TROWEL @ TOP. ENCASE IN 24" DIA
CONCRETE BASE 36" DEEP
GREASE FITTING AT
EACH HINGE POINT
2" X 2" X 1/4" STL ANGLE DOOR FRAME (STILES &
RAILS) -WELD TO DOOR PIVOT -SHOP PRIME & PAINT
1-1/2", 22 GA GALVANIZED CORRUGATED METAL
DECKING "C" PANELS (PAINTED)
-WELD TO DOOR FRAME AS SHOWN
16" X 8" BLOCK
8"
NOTE: ALL EXPOSED METAL AND CMU SURFACES FOR TRASH ENCLOSURE
TO BE PAINTED WITH EXTERIOR GRADE EPOXY PAINT, COLOR TO MATCH
FLASHING, TYP.
9" DIA. SCHEDULE 80
STEEL PIPE PIVOT -
PROVIDE STEEL SHIM
BETWEEN PIVOT &
BOLLARD - PAINT W/
EXTERIOR GRADE
EPOXY PAINT, COLOR
TO MATCH FLASHING
GREASE
FITTING AT
EACH HINGE
POINT
2" x 2" x 1/4" STL.
ANGLE DOOR FRAME
(STILES & RAILS) -
WELD TO DOOR
PIVOT - SHOP PRIME &
PAINT
8" DIA. SCHEDULE 40
STEEL BOLLARD
GROUT SOLID &
ROUND & TROWEL @
TOP. ENCASE IN 24"
DIA CONCRETE BASE
36" DEEP - PAINT W/
EXTERIOR GRADE
EPOXY PAINT, COLOR
TO MATCH FLASHING
TRASH ENCLOSURE
DOOR:
2" x 2" x 1/4" STEEL
ANGLE STILES & RAILS
WITH 1-1/2", 22 GA
GALVANIZED
CORRUGATED METAL
DECKING "C" PANELS &
1-1/4" x 1-1/4" X 3/16"
STEEL ANGLE BRACE -
SHOP PRIME ANGLES &
PAINT 1' - 0"2"PLAN
NORTH10
15397
TRASH
ENCLOSURE
1
A100
Sim
OFFICE BLDG PHASE 1
1ST FLOOR 3,916 SF
2ND FLOOR 1,618 SF
5,534/250 = 22.136 STALLS
FUTURE OFFICE ADDITION
1ST FLOOR 1,378
2ND FLOOR 1,378
2,756/250 = 11.24
FINISHED
20' - 4"FINISHED7' - 6"FINISHED
10' - 2"FINISHED7' - 6"2
A100
Sim
FINISHED
20' - 4"FINISHED7' - 6"2
A100
Sim
WILKUS ARCHITECTS Trash Enclosure Plan, Details
A100
KETTLEVIEW INSURANCE BUILDING
2019.02.01
A100
ENLARGED TRASH ENCLOSURE PLAN1
A100
TYP. TRASH ENCLOSURE WALL2
A100
DUMPSTER CANE BOLT DETAIL3
A100
DUMPSER WALL DETAIL4
A100
DUMPSTER PIVOT DETAIL5
A100
DUMPSTER ENCLOSURE ELEVATION7
A100
DUMPSTER ENCLOSURE8
A100
DUPSTER ENCLOSURE9