HomeMy WebLinkAbout2018-06-04-J04 Stivers_Site Plan AGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: June 4, 2018 AGENDA ITEM: Consideration of approval of a resolution approving a site plan for Stivers Ford Lincoln (1350 SE Stone Ridge Drive) FORMAT: Resolution SYNOPSIS INCLUDING PRO & CON: Stivers Ford Lincoln, requests approval of a site plan to allow for the construction of a single-story building that is approximately 17,000 square feet in area, located at 1350 SE Stone Ridge Drive. In addition to the proposed building, the applicant is proposing paving of a sales display lot in order to provide a total of 204 parking spaces for the purpose of displaying vehicles for sale. The applicant has provided elevations for proposed building on the site, which meets the intent of the architectural guidelines within the Site Development and Building Standards Ordinance. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning Commission reviewed this project at the May 22, 2018 Commission Meeting and recommended approval subject to remaining staff comments: Approval of a Site Plan for Stivers Ford Lincoln (1350 SE Stone Ridge Drive) City Planner Melissa DeBoer introduced the request for approval of a Site Plan made by the applicant Stiver’s Iowa Real Estate, LLC. The property is generally located west of SE Waco Place and south of SE Stone Ridge Drive, containing approximately 3.79 acres. Mrs. DeBoer advised that the area is currently used as overflow parking for Stiver’s, and there has been an approved site plan to pave the area, however, no work on that project has been completed. At this time, the applicant has decided to expand their business and now seek to place a separate auto body shop and display parking lot within the same project. The proposed single story building is approximately 17,000 square feet in area and includes a small office area in addition to the repair space. The display lot would contain a total of 204 parking spaces for displaying vehicles currently for sale. Mrs. DeBoer advised that driveways off of SE Stone Ridge Drive and SE Waco Place provide access to the lot. A 5 foot sidewalk will be constructed along SE Stone Ridge Drive and Pedestrian Ramps throughout the site will be constructed or repaired with site improvements. All utilities are available at the site and storm water will be detained in the basin south of the site. All landscaping, open space, and lighting ordinance requirements have been met. J4 At this time Staff recommends approval of the site plan for Stiver’s Body Shop subject to remaining staff comments.  Commissioner Hoifeldt questioned about the concrete product set to be used for the shop construction. Representatives of the applicant explained that with the concrete coated foam, the construction can take the insulation down to the foundation, which is the best thing to do with a metal frame building.  Commissioner Hoifeldt questioned if there were any issues with repair cars being out among the sale vehicles? Senior Planner, Andy Kass, advised that the applicant would not be able to have cars needing repairs out on the display lot without screening.  Commissioner Streit clarified that it was an expansion of the current auto sales space. The applicant representatives advised that was correct. The current auto body shop has a lot of turn over so a separate site would be beneficial. Also, they were tired of parking on grass and causing wear and tear on pedestrian walk ways by driving over them. Commissioner Hoifeldt moved to approve the site plan for Stiver’s Body Shop, subject to remaining staff comments. Commissioner Streit seconded the motion. Ayes: Ward, Sandie, Streit, Broderick, Hoifeldt, and Martin. Nays: None. Motion Carries. STAFF REVIEW AND COMMENT: All comments have been addressed. Staff recommends approval. RECOMMENDATION: Approve the resolution. ATTACHMENTS: I. Proposed Resolution II. Staff Report III. Site Plan & Elevations PREPARED BY: Melissa DeBoer, Planner II REVIEWED BY: THE CITY OF WAUKEE, IOWA RESOLUTION 18- APPROVING THE SITE PLAN FOR STIVERS FORD LINCOLN (1350 SE STONE RIDGE DRIVE) IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Site Plan for Stivers Ford Lincoln, subject to remaining staff comments on May 22, 2018; AND, WHEREAS, the Site Plan for Stivers Ford Lincoln is in general conformance with §304 – Site and Building Development Standards Ordinance of the Waukee Municipal Code; AND, WHEREAS, the Site Plan for Stivers Ford Lincoln is in general conformance with §301.27(A) – Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND, NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 4th day of June, 2018 that the Site Plan for Stivers Ford Lincoln is approved. ____________________________ William F. Peard, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk ROLL CALL VOTE AYE NAY ABSENT ABSTAIN Anna Bergman R. Charles Bottenberg Courtney Clarke Shelly Hughes Larry R. Lyon PLANNING AND ZONING COMMISSION STAFF REPORT PROJECT: Stivers Body Shop – Site Plan PREPARED BY: Melissa DeBoer, AICP – Planner II REPORT DATE: May 18, 2018 MEETING DATE: May 22, 2018 GENERAL INFORMATION Applicant / Owner: Stivers Iowa Real Estate, LLC Engineer: Michael Wahlert, Bishop Engineering Company, Inc. Request: The applicant is requesting approval of a site plan for an auto body shop and display lot. Location and Size: Property is generally located west of SE Waco Place and south of SE Stone Ridge Drive, containing approximately 3.79 acres. Property Address: 1350 SE Stone Ridge Drive AREA MAP ABOVE: Aerial of subject property (outlined in YELLOW) in relation to the surrounding area. May 18, 2018 2 of 3 LAND USES AND ZONING Location Existing Land Use Comprehensive Plan Current Zoning Property in Question Undeveloped / Stivers Overflow Display Lot Parking Neighborhood Residential C-1 / PD-1 ( Community & Highway Service Commercial District / Planned Development Overlay) North Retail Neighborhood Residential C-1 / PD-1 ( Community & Highway Service Commercial District / Planned Development Overlay) South Alice Place Senior Living Neighborhood Residential R-3 / PD-1 (Multi-Family Residential District / Planned Development Overlay) East Stivers Ford Lincoln Auto Dealership Neighborhood Residential C-1 (Community & Highway Service Commercial District) West Vacant / Undeveloped Neighborhood Residential C-1 / PD-1 ( Community & Highway Service Commercial District / Planned Development Overlay) HISTORY The subject property is currently used as an overflow parking area for Stivers. They recently submitted for approval of a site plan to pave a parking lot on the subject site. However, since the time of receiving approval of that site plan, they have decided to expand their business by adding a separate auto body shop and adding a display parking lot within the same project. The site today is still undeveloped. PROJECT DESCRIPTION The project involves the construction of one single-story building to be used as an auto body shop. The building is approximately 17,000 square feet in area and will include an office that makes up approximately 868 square feet of the overall building. The remaining 16,221 square feet will be made up of repair space. The other part of the project includes the paving of a sales display lot. The site plan identifies a total of 204 parking spaces for displaying vehicles for sale. ACCESS AND PARKING Two driveways are proposed to provide access to this site. One will be located off of SE Stone Ridge Drive and the other off of SE Waco Place. The parking ordinance requires 3 parking spaces per service bay, 1 space per service vehicle, and 2.5 spaces per 1,000 square feet of non-service area. The total amount of parking required per the Ordinance is 31 parking spaces. The site plan identifies a total of 235 parking spaces to be provided across the entire site. The parking provided meets the requirements of the Ordinance. May 18, 2018 3 of 3 SIDEWALKS/TRAILS A 5 foot wide sidewalk will be constructed along SE Stone Ridge Drive as part of the site improvements. An existing 10 foot wide trail exists along SE Waco Place. Pedestrian ramps will be provides at the southwest corner of SE Waco Place and SE Stone Ridge Drive in order to provide a crossing to both the north and the east. A pedestrian connection will provide access into the site from the sidewalk along SE Stone Ridge Drive. UTILITIES All utilities are available at this site and services will be brought in to the site to serve the proposed building. Storm water will be detained in the existing detention basin located on the south side of the site. LANDSCAPING & OPEN SPACE A minimum of 20% of the project area is required to be open space. The total amount of open space proposed is approximately 30%. Landscaping is being provided per the requirements of the landscape ordinance. ELEVATIONS The elevations are proposed to be constructed mainly of metal panels in gray and blue. The front entrance of the building includes white EIFS. The trash enclosure will be composed of split face concrete block and a composite wood gate. The building includes several overhead doors to provide vehicle access to the service shop. LIGHTING A photometric plan has been provided that meets the requirements of the lighting ordinance. STAFF RECOMMENDATION Staff recommends approval of the site plan for Stivers Body Shop subject to remaining staff comments. 6SITESTIVERS FORD LINCOLNSITE PLANIOWAONE CALL1-800-292-8989www.iowaonecall.com811Know what's below. Call before you dig.PROPERTY DESCRIPTION:QUIT CLAIM DEED BOOK: 2015 PAGE: 20587LOT 4, 5, AND 6, IN WILLIAMS POINTE PLAT 14, AN OFFICIAL PLAT,NOW INCLUDED IN AND FORMING A PART OF THE CITY OF WAUKEE,DALLAS COUNTY, IOWA.SAID TRACT OF LAND SUBJECT TO ALL EASEMENTS ANDENCUMBRANCES OF RECORD.SAID TRACT OF LAND CONTAINS 3.79 (165,248 SF) ACRES MORE ORLESS.ADDRESS:1350 SE STONE RIDGE DRIVEWAUKEE, IOWA 50263OWNER:STIVERS IOWA REAL ESTATE LLC1450 EAST HICKMAN ROADWAUKEE, IOWA 50263PREPARED FOR:SCOTT POLITTESTIVERS FORD LINCOLN1450 EAST HICKMAN ROADWAUKEE, IOWA 50263ZONING:COMMERCIAL - (PD/C-1)BULK REGULATIONS: SETBACKS: FRONT = 30' REAR = 30' SIDE = NONEPARKING REQUIREMENTS:PARKING REQUIRED:3 SPACES PER SERVICE BAY @ 8 = 24 STALLS1 SPACE PER SERVICE VEHICLE @ 2 = 2 STALLS2.5/1,000SF OF NON-SERVICE AREA @ 1,555SF = 5 STALLSTOTAL REQUIRED = 31 STALLS (2 ADA)PARKING PROVIDED = 235 (2 ADA) STALLSOPEN SPACE REQUIREMENTS:OPEN SPACE REQUIRED = 20.00% (33,049.60 SF)OPEN SPACE PROPOSED = 29.86% (49,336.61 SF)IMPERVIOUS SURFACE:EXISTING IMPERVIOUS SURFACE = 0 SFPROPOSE IMPERVIOUS SURFACE = 115,911.39 SFBENCHMARK:CP #9000:NE CORNER OF SE STONE RIDGE DRIVE & SE WACO PLACE3/4" IRON PIPE W/RPC N=588190.02E=1545997.53ELEV=1020.98'CP#9001:NE CORNER OF SE STONE RIDGE DRIVE & SE BRICK DRIVE3/4" IRON PIPE W/RPCN=588182.14E=1545278.84ELEV=1024.61'VICINITY MAPNOT TO SCALECOPYRIGHT 2017 BISHOP ENGINEERING. THIS DOCUMENT AND THE INFORMATION CONTAINED MAY NOT BEREPRODUCED OR EXCERPTED WITHOUT THE EXPRESS WRITTEN PERMISSION OF BISHOP ENGINEERING.UNAUTHORIZED COPYING OR DISCLOSURE OF CONSTRUCTION USE ARE PROHIBITED BY COPYRIGHT LAW.LEGEND: SAN SANITARY SEWER ST STORM SEWER W WATER LINE G GAS LINEU/E UNDERGROUND ELECTRICO/E OVERHEAD ELECTRICTELETELEPHONE LINEF/OFIBER OPTICCATVCABLE TVSTORM MANHOLECURB INTAKESURFACE INTAKEFLARED END SECTIONSANITARY MANHOLECLEANOUTFIRE HYDRANTSPRINKLERIRRIGATION CONTROL VALVEWATER MANHOLEWELLWATER VALVEWATER SHUT OFFYARD HYDRANTELECTRIC MANHOLEELECTRIC METERELECTRIC RISERELECTRIC VAULTPOWER POLETRANSFORMER POLELIGHT POLEELECTRIC JUNCTION BOXELECTRIC PANELTRANSFORMERGROUND LIGHTGUY WIREELECTRIC HANDHOLEGAS METERGAS VALVEAIR CONDITIONING UNITTELEPHONE RISERTELEPHONE VAULTTELEPHONE MANHOLETRAFFIC SIGNAL MANHOLEFIBER OPTIC RISERFIBER OPTIC FAULTCABLE TV RISERSIGN 7DENOTES NUMBER OF PARKING STALLSPROPERTY CORNER - FOUND AS NOTEDPROPERTY CORNER- PLACED 3/4" IRON PIPEWITH YELLOW PLASTIC CAP ID #14775SECTION CORNER - FOUND AS NOTEDDSCOHYDI CVWWSOYADREEMEELECEJEPGMGVA/CTTELTTSFOF/OTVWWVCOVER SHEETC0.1SHEET INDEX:C0.1COVER SHEETC0.2SITE SURVEYC1.1DEMO PLANC2.1LAYOUT PLANC3.1GRADING PLANC4.1UTILITY PLANC5.1LANDSCAPE PLANC7.1SWPPPUTILITY CONFLICT NOTES:1.UTILITY CONFLICTS MAY EXIST ACROSS THE SITE WITH NEW UTILITIES, GRADING, PAVING ETC.MOST UTILITY CONFLICTS HAVE BEEN CALLED OUT FOR CONTRACTOR CONVENIENCE.2.CONTRACTOR IS RESPONSIBLE FOR ALL UTILITY CONFLICTS THAT ARE EITHER CALLED OUT ONTHE PLANS OR THAT CAN BE SEEN ON THE PLANS BETWEEN AN EXISTING UTILITY ANDPROPOSED CONSTRUCTIONWETLAND NOTES:1.BISHOP ENGINEERING DOES NOT PERFORM WETLAND STUDIES OR WETLAND MITIGATION. IT ISTHE OWNER'S RESPONSIBILITY TO DETERMINE IF ANY WETLANDS ARE LOCATED ON THEPROJECT SITE AND PERFORM ANY NECESSARY MITIGATION PRIOR TO THE COMMENCEMENT OFCONSTRUCTION ACTIVITIES.SURVEY NOTES:1.SURVEY WORK WAS COMPLETED BY BISHOP ENGINEERING ON 7-27-2017. SEE SITE SURVEYPROVIDED AS PART OF THIS SET OF PLANS FOR EXISTING SITE CONDITIONS AND BOUNDARYINFORMATION.GENERAL NOTES:1.ALL WORK SHALL BE DONE IN ACCORDANCE WITH CITY OF WAUKEE STANDARD SPECIFICATIONS AND SUDAS STANDARD SPECIFICATIONS AND ANY AND ALLCITY/COUNTY SUPPLEMENTAL SPECIFICATIONS. THE CITY OF WAUKEE MUST BE NOTIFIED BY ALL CONTRACTORS 48 HOURS PRIOR TO COMMENCING WORK.2.IN EVENT OF A DISCREPANCY BETWEEN THE QUANTITY ESTIMATES AND THE DETAILED PLANS, THE DETAILED PLANS SHALL GOVERN.3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION OF ALL UTILITIES. ANY DAMAGE TO SAID UTILITIES SHALL BE REPAIRED AT THE CONTRACTORS EXPENSE.4.ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE CURRENT O.S.H.A. CODES AND STANDARDS. NOTHING INDICATED ON THESE PLANS SHALL RELIEVE THECONTRACTOR FROM COMPLYING WITH THE APPROPRIATE SAFETY REGULATIONS.5.ALL NECESSARY CONSTRUCTION SIGNS, BARRICADES AND OTHER TRAFFIC CONTROL DEVICES REQUIRED DURING CONSTRUCTION WILL BE FURNISHED BY THECONTRACTOR. SIGNS, BARRICADES AND OTHER TRAFFIC CONTROL DEVICES MUST BE IN CONFORMANCE WITH THE "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICESFOR STREETS AND HIGHWAYS."6.BISHOP ENGINEERING SHALL NOT BE LIABLE FOR ANY INJURIES THAT HAPPEN ON SITE. THIS SHALL INCLUDE BUT NOT BE LIMITED TO TRENCH COLLAPSES FROMVARYING SOIL CONDITIONS OR INJURIES CAUSED BY UNDERGROUND UTILITIES INCLUDING UTILITIES THAT ARE NOT SHOWN ON PLAN.7.THE CONTRACTOR IS LIABLE FOR ALL DAMAGES TO PUBLIC OR PRIVATE PROPERTY CAUSED BY THEIR ACTION OR INACTION IN PROVIDING FOR STORM WATER FLOWDURING CONSTRUCTION. DO NOT RESTRICT FLOWS IN EXISTING DRAINAGE CHANNELS, STORM SEWER, OR FACILITIES.8.THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER A SCHEDULE FOR PERFORMANCE OF WORK ITEMS. THIS SCHEDULE SHALL BE PROVIDED BY THE CONTRACTOR ATTHE PROJECT PRECONSTRUCTION CONFERENCE. NO WORK SHALL BEGIN UNTIL A SCHEDULE HAS BEEN SUBMITTED AND ACCEPTED. THE CONTRACTOR SHALL THENPERFORM WORK TO CONFORM TO THE ACCEPTED SCHEDULE.9.LABORATORY TESTS SHALL BE PERFORMED BY THE OWNER UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL PROVIDE SAMPLES OF MATERIAL REQUIRED FORLABORATORY TESTS AND TESTING IN ACCORDANCE WITH THE URBAN STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS.10.SOIL IMPORT OR EXPORT ON THIS PROJECT SHALL BE CONSIDERED INCIDENTAL AND WILL NOT BE MEASURED OR PAID FOR SEPARATELY.11.THE CONTRACTOR SHALL PROTECT ALL STRUCTURES NOT SHOWN AS REMOVALS ON THE PLANS.12.THE CONTRACTOR SHALL OBTAIN ANY AND ALL NECESSARY PERMITS PRIOR TO ANY CONSTRUCTION. CONTRACTOR SHALL WORK WITH OWNER OR OWNERSREPRESENTATIVE ON ALL REQUIRED STORM WATER DISCHARGE PERMITS FROM THE IOWA DEPARTMENT OF NATURAL RESOURCES AND THE CITY OF WAUKEE.13.GRADING AND EROSION CONTROL SHALL BE DONE IN ACCORDANCE WITH THE APPROVED GRADING PLAN, SWPPP, NPDES DOCUMENTS, AND IOWA DEPARTMENT OFNATURAL RESOURCES REQUIREMENTS.14.THE CONTRACTOR SHALL PICK UP ANY DEBRIS SPILLED ONTO THE ADJACENT RIGHT OF WAY OR ABUTTING PROPERTIES AS THE RESULT OF CONSTRUCTION, AT THEEND OF EACH WORK DAY AND PRIOR TO A RAIN EVENT.15.THE CONTRACTOR IS RESPONSIBLE FOR THE PROMPT REMOVAL OF ALL MUD THAT HAS BEEN TRACKED OR WASHED UNTO ADJACENT PROPERTY OR RIGHT OF WAYUNTIL SUCH TIME THAT PERMANENT VEGETATION HAS BEEN ESTABLISHED.16.DISPOSE OF ALL EXCESS MATERIALS AND TRASH IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL REQUIREMENTS. PROVIDE WASTE AREAS OR DISPOSAL SITESFOR EXCESS MATERIALS NOT DESIRABLE FOR INCORPORATION INTO THE PROJECT.17.ALL SIGNAGE SHALL REQUIRE A SEPARATE PERMIT FROM THE CITY OF WAUKEE DEVELOPMENT SERVICES DEPARTMENT.18.ANY PROPOSED CHANGES TO THIS PLAN SET SHALL BE APPROVED IN WRITING BY THE CITY OF WAUKEE DEVELOPMENT SERVICES DEPARTMENT.19.CONTRACTOR SHALL BE RESPONSIBLE FOR ANY CHANGES MADE DURING CONSTRUCTION THAT HAVE NOT BEEN GRANTED APPROVAL IN WRITING BY THE CITY OFWAUKEE DEVELOPMENT SERVICES DEPARTMENT.20.APPROVED FIRE APPARATUS ACCESS ROADS SHALL BE PROVIDED AS SOON AS CONSTRUCTION OF THE BUILDING COMMENCES.THE FIRE APPARATUS ACCESS ROADSHALL COMPLY WITH THE REQUIREMENTS OF THE IFC SECTION 503.2 AND SHALL EXTEND TO WITHIN 100 FEET OF ALL PORTIONS OF THE FACILITY AND ALL PORTIONS OFTHE EXTERIOR WALLS OF THE FIRST STORY OF THE BUILDING AS MEASURED BY AN APPROVED ROUTE AROUND THE EXTERIOR OF THE BUILDING OR FACILITY.PAVING NOTES:1.THE PAVING/ GRADING CONTRACTOR SHALL BACKFILL THE PAVING SLAB AND FINE GRADE THE RIGHT OF WAY AS SOON AFTER THE PAVING AS POSSIBLE. ALL AREASSHALL BE SODDED AND WATERED UNTIL ESTABLISHED IN ACCORDANCE WITH CITY OF WAUKEE STANDARD SPECIFICATIONS AND THE CURRENT VERSION OF SUDAS.2.SUBGRADE PREPARATION AND PAVEMENTS WILL BE CONSTRUCTED FOLLOWING RECOMMENDATIONS IN THE SOILS REPORT. APPROVED SOILS ENGINEER MUST SIGNOFF ON SUBASE PRIOR TO ANY PAVEMENT BEING PLACED.3.SEE DETAILS FOR ALL PAVEMENT THICKNESS.4.ALL PEDESTRIAN WALKWAYS THAT UNLOAD INTO A VEHICLES TRAVELED PATH MUST HAVE A.D.A. DETECTABLE WARNING PLANEL(S) AS PER A.D.A. REGULATIONS. PANELTYPE & COLOR SHALL BE PER CITY STANDARD.5.ALL WALKS, PARKING LOTS, HANDICAP PARKING, RAMPS, ETC. SHALL COMPLY WITH ALL A.D.A. AND CITY CODES. HANDICAP PARKING SIGNAGE IS REQUIRED FOR ALLHANDICAP STALLS AND SHALL BE CONSIDERED INCIDENTAL. IN EVENT OF A DISCREPANCY BETWEEN THE PLANS AND THE A.D.A./CITY CODES THE A.D.A./CITY CODESSHALL GOVERN. CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING A.D.A. CODES ARE MET.6.ALL DISTURBED AREAS THAT ARE NOT PAVED SHOULD BE SODDEDUTILITY NOTES:1.QUANTITY CALLOUTS ON PIPE LENGTHS ARE APPROXIMATE AND SHOULD BE USED FOR REFERENCE ONLY.2.THE CONTRACTOR SHALL PROVIDE AS-BUILTS OF ALL UTILITIES, INCLUDING DEPTH AND LOCATION OF ALL SERVICES.3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION AND ALL COSTS ASSOCIATED WITH AS-BUILT TOPO OF DETENTION POND & DETENTION POND STORMSEWER. CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING BISHOP ENGINEERING (DAVID BENTZ AT 515-276-0467) TO PERFORM SAID AS-BUILT SURVEY. IFDETENTION PONDS HAVE BEEN GRADED INCORRECTLY, CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SUBSEQUENT AS-BUILT TOPO SURVEYS UNTIL ISSUES HAVEBEEN RECTIFIED.4.THE CONTRACTOR SHALL COORDINATE THE ADJUSTMENT OF ANY AND ALL EXISTING AND PROPOSED UTILITIES TO PROPOSED GRADES. EXISTING UTILITIES SHALL BERAISED OR LOWERED IN ACCORDANCE WITH THE UTILITY OWNER REQUIREMENTS. ANY NECESSARY ADJUSTMENTS SHALL BE CONSIDERED INCIDENTAL TOCONSTRUCTION.5.ACTIVE EXISTING FIELD TILES ENCOUNTERED DURING CONSTRUCTION SHALL BE REPAIRED, REROUTED, OR CONNECTED TO PUBLIC OR PRIVATE STORM SEWER TOREMAIN IN SERVICE.6.ALL PROPOSED RCP STORM SEWER PIPE JOINTS SHALL BE FABRIC WRAPPED AND THE LAST 3 PIPE SECTIONS ON THE APRON SHALL BE TIED WITH RF-14 TYPE IICONNECTORS. ALL APRONS SHALL HAVE A STANDARD FOOTING AND TRASH GUARD.7.ALL RIP RAP CALLED OUT ON PLANS SHALL BE UNDERLAIN WITH ENGINEERING FABRIC.8.SANITARY SEWER SERVICE CONNECTIONS SHALL BE PLACED AT A SLOPE OF NO LESS THAN 2%. SERVICES SHALL MAINTAIN 18" OF VERTICAL SEPARATION FROM THEWATERMAIN WITH 18" OF COMPACTED LOW PERMEABILITY SOIL BETWEEN THE UTILITIES WITHIN 10' OF THE CROSSING.9.MANDREL AND PRESSURE TESTS SHALL BE REQUIRED FOR ALL PROPOSED SANITARY LINES. TELEVISING OF THE SANITARY SEWER SYSTEM SHALL BE COMPLETEDPRIOR TO PAVING UNLESS OTHERWISE APPROVED BY JURISDICTION.10.WATERMAINS SHALL BE C-900. SIZE OF WATERMAIN AS SHOWN ON PLANS.11.THRUST BLOCKS SHALL BE INSTALLED AS REQUIRED AND SHALL BE CONSIDERED INCIDENTAL TO WATERMAIN CONSTRUCTION.12.PROPOSED WATERMAIN SHALL BE PRESSURE TESTED, BACTERIA TESTED AND CHLORINATED. THE FILLING OF THE WATER MAIN SHALL BE DONE BY THE CITY OFWAUKEE.13.TRACER WIRE SHALL BE ADDED TO ALL WATER MAIN, AND BROUGHT TO THE SURFACE AT EVERY HYDRANT.14.ALL HYDRANTS WILL IMMEDIATELY BE COVERED WITH A BLACK PLASTIC BAG (OR EQUIVALENT) ONCE THE HYDRANT IS INSTALLED. THE CITY OF WAUKEE WILL NOTIFYTHE CONTRACTOR WHEN THE BAGS CAN BE REMOVED.15.THE MINIMUM HYDRANT LEAD SHALL BE 3.5 FEET.16.ALL HYDRANTS TO HAVE 4" STORZ FITTINGS.17.CONTRACTOR TO COORDINATE TIE-INS TO EXISTING UTILITIES WITH THE CITY OF WAUKEE PUBLIC WORKS DEPARTMENT.18.ALL UTILITIES TO BE TESTED TO CITY STANDARDS. CITY TO WITNESS ALL TESTING.REFERENCE NUMBER:3501 104th Street Des Moines, Iowa 50322-3825 Phone: (515)276-0467 Fax: (515)276-0217 "Planning Your Successful Development" Bishop Engineering Civil Engineering & Land Surveying Established 1959DRAWN BY:CHECKED BY:REVISION DATE:PROJECT NUMBER:SHEET NUMBER:1350 SE STONE RIDGE DRIVE WAUKEE, IOWAMJWCJB3-6-20184-19-20185-3-20185-8-20185-18-20185-23-2018180108PRELIMINARY- NOT FOR CONSTRUCTIONM:\LAND PROJECTS 2018\180108 - STIVERS FORD USED CAR EXPANSION\DWG\C0 COVER.DWG5/23/2018 1:57:07 PM UTILITY NOTE:THE LOCATION OF THE UTILITIES INDICATED ON THE PLANS HAVE BEEN TAKEN FROM THE FIELD SURVEY, EXISTING PUBLICRECORDS, AND PLANS PROVIDED BY OTHERS. SURFACE UTILITY LOCATIONS HAVE BEEN FIELD LOCATED BY BISHOPENGINEERING, UNLESS OTHERWISE NOTED. ALL UNDERGROUND UTILITY LOCATIONS ARE APPROXIMATE LOCATIONSONLY. BISHOP ENGINEERING DOES NOT GUARANTEE THE UNDERGROUND LOCATION OF ANY UTILITIES SHOWN. IT SHALLBE THE DUTY OF THE CONTRACTOR TO DETERMINE THE LOCATION AND DEPTH OF ANY UNDERGROUND UTILITIES SHOWNAND IF ANY ADDITIONAL UTILITIES, OTHER THAN THOSE SHOWN ON THE PLANS, MAY BE PRESENT. A REQUEST WAS MADETO IOWA ONE CALL FOR UTILITY PROVIDERS TO VERIFY, LOCATE, AND MARK THEIR UTILITIES IN THE FIELD.ABBREVIATIONS:ACACRESASPHASPHALTBKBOOKCONCCONCRETEDDEEDED DISTANCEEXEXISTINGENCLENCLOSUREFFFINISHED FLOORFLFLOW LINEFRACFRACTIONALMMEASURED DISTANCEMHMANHOLEOPCORANGE PLASTIC CAPPPLATTED DISTANCEPGPAGEPOBPOINT OF BEGINNINGPOCPOINT OF COMMENCEMENTPRAPREVIOUSLY RECORDED ASPUEPUBLIC UTILITY EASEMENTROWRIGHT OF WAYRPCRED PLASTIC CAPSFSQUARE FEETSANSANITARYTYPTYPICALYPCYELLOW PLASTIC CAPNNORTHSSOUTHEEASTWWESTUTILITY MAPS PROVIDED BY:1. ELECTRIC (MIDAMERICAN ENERGY / (888) 427-5632)2. STORM AND SANITARY (CITY OF WAUKEE / (515) 978-7398)3. GAS (CITY OF WAUKEE / (515) 978-7398)4. WATER (CITY OF WAUKEE / (515) 978-7398)C0.1, C1.1, C2.1, C3.1, C4.1, C6.1, & C7.1PROJECT MANAGER:JOSH BARBYNEUMANN BROTHERS1435 OHIO STREETDES MOINES, IOWA 50314BARBYJ@NEUMANNBROS.COM(515) 243-0156 WWWW W W W W W W U/EU/EU/EU/EU/EU/EU/EU/EU/E U/EU/EU/EU/EU/EU/EU/E U/E U/E U/E U/E U/E U/E U/E U/EW U/E CP #9000CP #9001WVWVWVWVHYDHYDTBM: ARROW ON HYDRANTELEV=1024.11WVWVTEX INTAKET/C=1017.00EX INTAKET/C=1017.02DEX STORM MHRIM=1020.92WVHYDTBM: ARROW ON HYDRANTELEV=1020.34WVHYDDEX STORM MHRIM=1017.76DEX STORM MHRIM=1022.35FL(S)=1018.45FL(W)=1018.40FL(E)=1018.25DEX STORM MHRIM=1018.16FL(W)=1012.96FL(SW)=1012.76FL(S)=1012.01FL(E)=1011.94DEX STORM MHRIM=1017.21FL(S)=1012.26FL(W)=1011.03FL(N)=1011.03EX INTAKET/C=1017.01FL(N,S)=1011.02EX INTAKET/C=1016.99EX INTAKET/C=1025.86EX INTAKET/C=1025.88DEX STORM MHRIM=1025.96FL(W)=1021.61FL(NE)=1020.86EX INTAKET/C=1025.94EX INTAKET/C=1025.84FL(E)=1021.78TESEX SAN MHRIM=1026.46INV(E,W)=1009.46ELECDEX STORM MHRIM=1024.91FL(SW)=1020.51FL(E)=1010.28HYDHYDTBM: BURY BOLTELEV=1024.184" TREE4" TREE4" TREE4" TREE4" TREE4" TREE4" TREE4" TREE4" TREEEX INTAKET/C=1021.42FL(W)=1016.97WVEX INTAKET/C=1024.77FL(E)=10021.37EX INTAKET/C=1024.77WVWVWVHYDSEX SAN MHRIM=1026.36EX 15" FESFL=1018.99WSOWVHYDWVWVWVHYDWVWSOSEX SAN MHRIM=1022.87INV(S)=1005.16INV(E,W)=1005.14SEX SAN MHRIM=1021.54INV(N,E,W)=1004.54EX 15" FESFL=1015.76WSOEX 15" FESFL=1013.83EX 48" FESFL=1016.98DEX STORM MHRIM=1021.96FL(S,N)=1016.56WVHYDSEX SAN MHRIM=1026.10INV(N,S)=1008.05SEX SAN MHRIM=1021.20INV(S)=1001.38INV(W)=1001.20INV(S)=1001.04DEX STORM MHRIM=1022.17FL(E)=1016.47FL(S)=1014.85FL(N)=1014.97EX INTAKET/C=1021.68FL(E)=1017.18FL(W)=1017.15SEX SAN MHRIM=1025.00INV(S)=1007.24INV(W)=UNKNOWNINV(N)=1005.17SEX STORM MHRIM=1024.81FL(S)=1016.70FL(N)=1016.41DEX STORM MHRIM=1024.89FL(N,S)=1019.16EX INTAKET/C=1024.82FL(E,W)=20.89EX INTAKET/C=1024.776" TREE6" TREE6" TREE6" TREE6" TREE6" TREE6" TREE6" TREE6" TREE6" TREE6" TREEEX 15" FESFL=1021.96EX 36" FESFL=1016.64WWWWWW W W W W W WWWWWWWWWWWW ST42"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN10"SAN 10"SAN10" SAN10"SAN10"SAN10"SAN10"ST15"ST15"ST18"ST18"ST18"STST 42"ST 42"ST 42"ST 42"ST 42"ST36"ST36"ST36"ST36"ST15"10' PUE BK. 2007 PG. 15339 30' PRIVATE INGRESS/EGRESS EASEMENT BK. 2007 PG. 15333 25' PUBLIC STORM SEWERAND OVERLANDFLOWAGE EASEMENTBK. 2007 PG. 1533715' PRIVATE STORMSEWER EASEMENTBK. 2007 PG. 1533617.5'15' PRIVATE WATER MAIN EASEMENT BK. 2007 PG. 15332 PRIVATE 15'STORM SEWER EASEMENTBK. 2007 PG. 1533623.83'N00°08'00"E7.46'ST48"ST48"ST48"30' PRIVATEINGRESS/EGRESSEASEMENTBK. 2007 PG. 1533365' PRIVATE OVERLANDFLOWAGE AND DETENTIONEASEMENT BK. 2007 PG. 15328 SE STONE RIDGE DRIVESE BRICK DRIVE SE WACO PLACE 7.5' PUBLIC STORMSEWER EASEMENTBK. 2007 PG. 153381.39'62.4'88.34'25' PRIVATE SANITARYSEWER EASEMENTBK. 2007 PG. 1533115'30' PRIVATEINGRESS/EGRESS EASEMENTBK. 2007 PG. 1533325' BUILDING SETBACK25' BUILDING SETBACKREGIONAL DETENTION POND100-YR HWEL = 1020.48LOT 2LOT 3LOT 4LOT 7LOT 6LOT 5SAN 10" ST 42"℄℄℄℄SAN8" W ST 36"ST 36"ST 36"ST 36"ST 36"ST 36"10281027102610251024 10231022102110311030102910281027102510231022 1020103110301029102810271026102510241023102210211020101910181017 1022102310241025102610261025 1025102610251024 10 2 4 102310221021102010191018101510161 0 1 710171019102010211021102310241025102510241023102210211020101910251020 1020 102 5 10231022102110 2 1 10 2 2 10 2 3 EX 25 LF 15" RCP@ S=4.86%WIL L I A M S P O I N T E P L A T 1 4 55,044 SF55,098 SF54,960 SF55,119 SF55,169 SF55,067 SF105 1250155 130013201350100150 80' ROW70' ROW 100' ROW15' PRIVATESTORM SEWEREASEMENTBK. 2007 PG. 1533610' PUEBK. 2007 PG. 153396SITEREFERENCE NUMBER:3501 104th Street Des Moines, Iowa 50322-3825 Phone: (515)276-0467 Fax: (515)276-0217 "Planning Your Successful Development" Bishop Engineering Civil Engineering & Land Surveying Established 1959DRAWN BY:CHECKED BY:REVISION DATE:PROJECT NUMBER:SHEET NUMBER:LOTS 2-7 WILLIAMS POINTE PLAT 14 SITE SURVEYMJWLDH170359C0.2STIVERS FORD LINCOLNSITE SURVEYVICINITY MAPNOT TO SCALEM:\LAND PROJECTS 2017\170359 - STIVERS LOT EXPANSION\DWG\SITE SURVEY.DWG9/26/2017 8:33:14 AMIOWAONE CALL1-800-292-8989www.iowaonecall.com811Know what's below. Call before you dig.PROPERTY DESCRIPTION:QUIT CLAIM DEED BOOK: 2015 PAGE: 20587LOTS 2, 3, 4, 5, 6 AND 7, IN WILLIAMS POINTE PLAT 14, ANOFFICIAL PLAT, NOW INCLUDED IN AND FORMING A PART OFTHE CITY OF WAUKEE, DALLAS COUNTY, IOWA.SAID TRACT OF LAND SUBJECT TO ALL EASEMENTS ANDENCUMBRANCES OF RECORD.SAID TRACT OF LAND CONTAINS 7.586 ACRES (330,430 SF)MORE OR LESS.ADDRESS:1350 SE STONE RIDGE DRIVEWAUKEE, IOWA 50263OWNER:STIVERS IOWA REAL ESTATE LLC1450 EAST HICKMAN ROADWAUKEE, IOWA 50263PREPARED FOR:SCOTT POLITTESTIVERS FORD LINCOLN1450 EAST HICKMAN ROADWAUKEE, IOWA 50263ZONING:COMMERCIAL - (C)SITE CONTROL AND BENCHMARKS:BASIS OF BEARING OBTAINED FROM GPS OBSERVATIONSDATUM = NAD 83, IOWA SOUTHBENCHMARK DATUM = NAVD88, GEOID 12ACP #9000:NE CORNER OF SE STONE RIDGE DRIVE & SE WACO PLACE3/4" IRON PIPE W/RPC N=588190.02E=1545997.53ELEV=1020.98'CP#9001:NE CORNER OF SE STONE RIDGE DRIVE & SE BRICK DRIVE3/4" IRON PIPE W/RPCN=588182.14E=1545278.84ELEV=1024.61'UTILITY NOTE:THE LOCATION OF THE UTILITIES INDICATED ON THE PLANS HAVE BEEN TAKEN FROM THE FIELD SURVEY, EXISTING PUBLICRECORDS, AND PLANS PROVIDED BY OTHERS. SURFACE UTILITY LOCATIONS HAVE BEEN FIELD LOCATED BY BISHOPENGINEERING, UNLESS OTHERWISE NOTED. ALL UNDERGROUND UTILITY LOCATIONS ARE APPROXIMATE LOCATIONSONLY. BISHOP ENGINEERING DOES NOT GUARANTEE THE UNDERGROUND LOCATION OF ANY UTILITIES SHOWN. IT SHALLBE THE DUTY OF THE CONTRACTOR TO DETERMINE THE LOCATION AND DEPTH OF ANY UNDERGROUND UTILITIES SHOWNAND IF ANY ADDITIONAL UTILITIES, OTHER THAN THOSE SHOWN ON THE PLANS, MAY BE PRESENT. A REQUEST WAS MADETO IOWA ONE CALL FOR UTILITY PROVIDERS TO VERIFY, LOCATE, AND MARK THEIR UTILITIES IN THE FIELD.FIELD WORK COMPLETED ON: 7-27-2017COPYRIGHT 2017 BISHOP ENGINEERING. THIS DOCUMENT AND THE INFORMATION CONTAINED MAY NOT BEREPRODUCED OR EXCERPTED WITHOUT THE EXPRESS WRITTEN PERMISSION OF BISHOP ENGINEERING.UNAUTHORIZED COPYING OR DISCLOSURE OF CONSTRUCTION USE ARE PROHIBITED BY COPYRIGHT LAW.ABBREVIATIONS:ACACRESASPHASPHALTBKBOOKCONCCONCRETEDDEEDED DISTANCEEXEXISTINGENCLENCLOSUREFFFINISHED FLOORFLFLOW LINEFRACFRACTIONALMMEASURED DISTANCEMHMANHOLEOPCORANGE PLASTIC CAPPPLATTED DISTANCEPGPAGEPOBPOINT OF BEGINNINGPOCPOINT OF COMMENCEMENTPRAPREVIOUSLY RECORDED ASPUEPUBLIC UTILITY EASEMENTROWRIGHT OF WAYRPCRED PLASTIC CAPSFSQUARE FEETSANSANITARYTYPTYPICALYPCYELLOW PLASTIC CAPNNORTHSSOUTHEEASTWWESTLEGEND: SAN SANITARY SEWER ST STORM SEWER W WATER LINE G GAS LINEU/E UNDERGROUND ELECTRICO/E OVERHEAD ELECTRICTELETELEPHONE LINEF/OFIBER OPTICCATVCABLE TVSTORM MANHOLECURB INTAKESURFACE INTAKEFLARED END SECTIONSANITARY MANHOLECLEANOUTFIRE HYDRANTSPRINKLERIRRIGATION CONTROL VALVEWATER MANHOLEWELLWATER VALVEWATER SHUT OFFYARD HYDRANTELECTRIC MANHOLEELECTRIC METERELECTRIC RISERELECTRIC VAULTPOWER POLETRANSFORMER POLELIGHT POLEELECTRIC JUNCTION BOXELECTRIC PANELTRANSFORMERGROUND LIGHTGUY WIREELECTRIC HANDHOLEGAS METERGAS VALVEAIR CONDITIONING UNITTELEPHONE RISERTELEPHONE VAULTTELEPHONE MANHOLETRAFFIC SIGNAL MANHOLEFIBER OPTIC RISERFIBER OPTIC FAULTCABLE TV RISERSIGN 7DENOTES NUMBER OF PARKING STALLSPROPERTY CORNER - FOUND AS NOTEDSECTION CORNER - FOUND AS NOTEDSITE CONTROL POINT - MONUMENT AS NOTEDDSCOHYD I CVWWSOYADREEMEELECEJEPGMGVA/CTTELTTSFOF/OTVWWVC0.2GRAPHIC SCALE040204080SCALE: 1" =40'UTILITY MAPS PROVIDED BY:1. ELECTRIC (MIDAMERICAN ENERGY / (888) 427-5632)2. STORM AND SANITARY (CITY OF WAUKEE / (515) 249-12123. GAS (MIDAMERICAN ENERGY / (888) 427-5632)4. WATER (CITY OF WAUKEE / (515) 249-1212) WWWW W W W W W W U/EU/EU/EU/EU/EU/EU/EU/EU/E U/EU/EU/EU/EU/EU/EU/E U/E U/E U/E U/E U/E U/E U/E U/EW U/E CP #9000CP #9001WVWVWVWVHYDHYDTBM: ARROW ON HYDRANTELEV=1024.11WVWVTEX INTAKET/C=1017.00FL(S)=1010.82EX INTAKET/C=1017.02DEX STORM MHRIM=1020.92WVHYDTBM: ARROW ON HYDRANTELEV=1020.34WVHYDDEX STORM MHRIM=1017.76DEX STORM MHRIM=1022.35FL(S)=1018.45FL(W)=1018.40FL(E)=1018.25DEX STORM MHRIM=1018.16FL(W)=1012.96FL(SW)=1012.76FL(S)=1012.01FL(E)=1011.94DEX STORM MHRIM=1017.21FL(S)=1011.26FL(W)=1011.03FL(N)=1011.03EX INTAKET/C=1017.01FL(N,S)=1011.02EX INTAKET/C=1016.99EX INTAKET/C=1025.86EX INTAKET/C=1025.88DEX STORM MHRIM=1025.96FL(W)=1021.61FL(NE)=1020.86EX INTAKET/C=1025.94EX INTAKET/C=1025.84FL(E)=1021.78TESEX SAN MHRIM=1026.46INV(E,W)=1009.46ELECDEX STORM MHRIM=1024.91FL(SW)=1020.51FL(E)=1010.28HYDHY DTBM: BURY BOLTELEV=1024.184" TREE4" TREE4" TREE4" TREE4" TREE4" TREE4" TREE4" TREE4" TREEEX INTAKET/C=1021.42FL(W)=1016.97WVEX INTAKET/C=1024.77FL(E)=10021.37EX INTAKET/C=1024.77WVWVWVHYDSEX SAN MHRIM=1026.36EX 15" FESFL=1018.99WSOWVHYDWVWVWVHYDWVW SOSEX SAN MHRIM=1022.87INV(S)=1005.16INV(E,W)=1005.14SEX SAN MHRIM=1021.54INV(N,E,W)=1004.54EX 15" FESFL=1015.76W SOEX 15" FESFL=1013.83EX 48" FESFL=1016.98DEX STORM MHRIM=1021.96FL(S,N)=1016.56WVHYDSEX SAN MHRIM=1026.10INV(N,S)=1008.05SEX SAN MHRIM=1021.20INV(S)=1001.38INV(W)=1001.20INV(S)=1001.04DEX STORM MHRIM=1022.17FL(E)=1016.47FL(S)=1014.85FL(N)=1014.97EX INTAKET/C=1021.68FL(E)=1017.18FL(W)=1017.15SEX SAN MHRIM=1025.00INV(S)=1007.24INV(W)=UNKNOWNINV(N)=1005.17SEX STORM MHRIM=1024.81FL(S)=1016.70FL(N)=1016.41DEX STORM MHRIM=1024.89FL(N,S)=1019.16EX INTAKET/C=1024.82FL(E,W)=20.89EX INTAKET/C=1024.776" TREE6" TREE6" TREE6" TREE6" TREE6" TREE6" TREE6" TREE6" TREE6" TREE6" TREEEX 15" FESFL=1021.96EX 36" FESFL=1016.64W8"W8"W W W W W W WWWWWWWWWWW6"W6"ST42"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN 10"SAN 10"SAN 10" SAN 10"SAN 10"SAN 10"SAN10"SAN10"ST15"ST15"ST18"ST18"ST18"STST 42"ST 42"ST 42"ST 42"ST 42"ST36"ST36"ST36"ST36"ST15"10' PUE BK. 2007 PG. 15339 30' PRIVATE INGRESS/EGRESS EASEMENT BK. 2007 PG. 15333 25' PUBLIC STORM SEWERAND OVERLANDFLOWAGE EASEMENTBK. 2007 PG. 1533715' PRIVATE STORMSEWER EASEMENTBK. 2007 PG. 1533617.5'15' PRIVATE WATER MAIN EASEMENT BK. 2007 PG. 15332 PRIVATE 15'STORM SEWER EASEMENTBK. 2007 PG. 1533623.83'N00°08'00"E7.46'ST48"ST48"ST48"30' PRIVATE INGRESS/EGRESS EASEMENT BK. 2007 PG. 15333 65' PRIVATE OVERLAND FLOWAGE AND DETENTION EASEMENT BK. 2007 PG. 15328 SE STONE RIDGE DRIVESE BRICK DRIVE SE WACO PLACE 7.5' PUBLIC STORMSEWER EASEMENT BK. 2007 PG. 153381.39'62.4'88.34'25' PRIVATE SANITARYSEWER EASEMENTBK. 2007 PG. 1533115'30' PRIVATEINGRESS/EGRESS EASEMENTBK. 2007 PG. 1533325' BUILDING SETBACK25' BUILDING SETBACKREGIONAL DETENTION POND100-YR HWEL = 1020.48LOT 2LOT 3LOT 4LOT 7LOT 6LOT 5SAN 10" ST 42"℄℄℄℄SAN8"SAN 8" W6" ST 36"ST 36"ST 36"ST 36"ST 36"ST 36"10281027102610251024 1023102210211031103010291028102710251024102210201031103010291028 1027 1 0 2 6 1 0 2 5 1 0 2 4 102310221021102010191018101710221023102410251026102610251026102510241 0 2 3 1022102110201019101810151016101710171019102010211021102310 2 4 1025 1025102410231022102110201019102510201020 102 5 1023102210211021 102 2 EX 25 LF 15" RCP@ S=4.86%WIL L I A M S P O I N T E P L A T 1 4 55,044 SF55,098 SF54,960 SF55,119 SF55,169 SF55,067 SF15' PRIVATESTORM SEWEREASEMENTBK. 2007 PG. 1533610' PUEBK. 2007 PG. 15339W8"1021 1022102310241025 G G G G G G G G G G G G GGG GGGGGGGGGGGGGGGGGGGGGG(GAS PER MAP)5' PARKING SETBACK5' PARKING SETBACK 10' PARKING SETBACK25' BUILDING SETBACK25' BUILDING SETBACK 25' BUILDING SETBACK REMOVE & REPLACEEX. SIDEWALK & RAMPSGRIND DOWNEX. CURBGRIND DOWNEX. CURBREMOVE EX.15" RCP FES69.95'59.94'SALVAGE HYDRANT ASSEMBLYREF. C4.1 UTILITY FOR INSTILLATIONREMOVE 32LF WATER SERVICEDEMO NOTES:1.SAWCUT & REMOVE ALL PAVEMENT TO FULL DEPTH OF SLAB.2.PROTECT ALL TREES NOT CALLED OUT FOR REMOVAL WITHORANGE CONSTRUCTION FENCE AT THE DRIP LINE.3.PAVEMENT STRIPING CALLED OUT FOR REMOVAL SHALL BESANDBLASTED. NO GRINDING WILL BE ALLOWED.4.CONTRACTOR TO PROTECT STORM SEWER AND DRAINAGEWAYS FROM SLURRY DISCHARGE DUE TO CONCRETESAWCUTTING AND/OR CONCRETE GRINDING PER THE NPDESGENERAL PERMIT NO. 2.DEMO PLANC1.1REFERENCE NUMBER:3501 104th Street Des Moines, Iowa 50322-3825 Phone: (515)276-0467 Fax: (515)276-0217 "Planning Your Successful Development" Bishop Engineering Civil Engineering & Land Surveying Established 1959DRAWN BY:CHECKED BY:REVISION DATE:PROJECT NUMBER:SHEET NUMBER:1350 SE STONE RIDGE DRIVE WAUKEE, IOWAMJWCJB3-6-20184-19-20185-3-20185-8-20185-18-20185-23-2018180108PRELIMINARY- NOT FOR CONSTRUCTIONGRAPHIC SCALE040204080M:\LAND PROJECTS 2018\180108 - STIVERS FORD USED CAR EXPANSION\DWG\C1 DEMO.DWG5/23/2018 1:57:50 PM 5" PCC SIDEWALK30'PROP. 35'INGRESS/EGRESSEASEMENT59.01'M S00°06'27"E 35.00'MS89°40'04"E59.27'M N00°06'27"W 30'24'24' 18'8.5'9' (TYP)8'8'DREFUSE ENCLOSUREREF. ARCH. FOR DETAILPROPOSED BUILDING17,089 SFFF = 1023.50868 SF OFFICE16,221 SF MISC. REPAIRHYDWVHYD 12234.67'10'1134373737401124'R8' 35.03'30'24'WVR 2 9 'R5'R5'R 5 'R1 5 ' R 5 'R5'R1 5 ' R 5 'R5'R 5 'R5'R 1 0 'R2.5'R5'R5'R 5 'R4.5'R5'R 5 ' R 5 ' 19' 18' 24'19'24'76.69'51.5'PROP. 40'OVERLAND FLOWAGEEASEMENTGM40.00'MN89°41'28"W109.59'M N00°18'32"E 40.00'MS89°47'24"ECODISPLAY LOT PARKINGDISPLAY LOT PARKINGDISPLAY LOT PARKING26'R4.5'R4. 5 ' R 5 '5'NO CURB ONWEST EXTENTOF SLABR3 0 'R30'R30'R 3 0 '4' CURB CUTR 3 5 ' R35'30'8" PCC8" PCC7.5" PCC6.5" PCC7.5" PCC7.5" PCC7.5" PCC7.5" PCC7.5" PCC7.5" PCC6.5" PCC6.5" PCC6.5" PCC6.5" PCC6.5" PCC6.5" PCC6.5" PCCR 4 0 'R10'R5'R 5 '5'x5' STRUCTURALSTOOP (REF. ARCH.)5'x5' STRUCTURALSTOOP (REF. ARCH.)TAPER CURB19'19'18' 18'9'WWWW W W W W W W U/EU/EU/EU/EU/EU/EU/EU/EU/E U/EU/EU/EU/EU/EU/EU/E U/E U/E U/E U/E U/E U/E U/E U/EW U/E CP #9000CP #9001WVWVWVWVHYDHYDWVWVTDWVHYDWVHYDDDDDDTESELECDHYDHYD4" TREE4" TREE4" TREE4" TREE4" TREE4" TREE4" TREE4" TREE4" TREEWVWVSWSOWVHYDWVWV WVHYDWVWSO SSWSODWVHYDSSDSSD6" TREE6" TREE6" TREE6" TREE6" TREE6" TREE6" TREE6" TREE6" TREE6" TREE6" TREEW8"W8"W W W W W W WWWWWWWWWWW6"W6"ST42"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN 10"SAN 10"SAN 10" SAN10"SAN10"SAN10"SAN10"SAN10"ST15"ST15"ST18"ST18"ST18"STST 42"ST 42"ST 42"ST 42"ST 42"ST36"ST36"ST36"ST36"ST15"10' PUE BK. 2007 PG. 15339 30' PRIVATE INGRESS/EGRESS EASEMENT BK. 2007 PG. 15333 25' PUBLIC STORM SEWERAND OVERLANDFLOWAGE EASEMENTBK. 2007 PG. 1533715' PRIVATE STORMSEWER EASEMENTBK. 2007 PG. 1533617.5'15' PRIVATE WATER MAIN EASEMENT BK. 2007 PG. 15332 PRIVATE 15'STORM SEWER EASEMENTBK. 2007 PG. 153367.46'ST48"ST48"ST48"30' PRIVATEINGRESS/EGRESSEASEMENTBK. 2007 PG. 15333 65' PRIVATE OVERLAND FLOWAGE AND DETENTION EASEMENT BK. 2007 PG. 15328 SE STONE RIDGE DRIVESE BRICK DRIVE SE WACO PLACE 7.5' PUBLIC STORMSEWER EASEMENTBK. 2007 PG. 153381.39'62.4'88.34'25' PRIVATE SANITARYSEWER EASEMENTBK. 2007 PG. 1533115'30' PRIVATEINGRESS/EGRESS EASEMENTBK. 2007 PG. 1533325' BUILDING SETBACK25' BUILDING SETBACKREGIONAL DETENTION POND100-YR HWEL = 1020.48LOT 2LOT 3LOT 4LOT 7LOT 6LOT 5SAN 10" ST 42"℄℄℄℄SAN 8" W6" ST 36"ST 36"ST 36"ST 36"ST 36"ST 36"WIL L I A M S P O I N T E P L A T 1 4 55,044 SF55,098 SF54,960 SF55,119 SF55,169 SF55,067 SF105 1250155 130013201350150 80' ROW70' ROW 100' ROW15' PRIVATESTORM SEWEREASEMENTBK. 2007 PG. 1533610' PUEBK. 2007 PG. 15339W8"G G G G G G G G G G G G G G GGGGG GGGGGGGGGGGGGGGGGGGG5' PARKING SETBACK5' PARKING SETBACK 10' PARKING SETBACK25' BUILDING SETBACK25' BUILDING SETBACK 25' BUILDING SETBACK GENERAL NOTES:1.ALL NON-SIDEWALK SLABS TO HAVE 9" OF SUBGRADEPREPARATION (SUBGRADE AND SLAB THICKNESS PERGSI GEOTECHNICAL REPORT). ALL PUBLIC SIDEWALKSTO BE 5" PCC.2.UNLESS OTHERWISE NOTED, PCC TO BE C-4 MIX.LAYOUT PLANC2.1REFERENCE NUMBER:3501 104th Street Des Moines, Iowa 50322-3825 Phone: (515)276-0467 Fax: (515)276-0217 "Planning Your Successful Development" Bishop Engineering Civil Engineering & Land Surveying Established 1959DRAWN BY:CHECKED BY:REVISION DATE:PROJECT NUMBER:SHEET NUMBER:1350 SE STONE RIDGE DRIVE WAUKEE, IOWAMJWCJB3-6-20184-19-20185-3-20185-8-20185-18-20185-23-2018180108PRELIMINARY- NOT FOR CONSTRUCTIONGRAPHIC SCALE040204080M:\LAND PROJECTS 2018\180108 - STIVERS FORD USED CAR EXPANSION\DWG\C2 LAYOUT.DWG5/23/2018 1:58:43 PM WWWW W W W W W W U/EU/EU/EU/EU/EU/EU/EU/EU/E U/EU/EU/EU/EU/EU/EU/E U/E U/E U/E U/E U/E U/E U/E U/EW U/E CP #9000CP #9001WVWVWVWVHYDHYDWVWVTDWVHYDWVHYDDDDDDTESELECDHYDHYDWVWVSWSOWVHYDWVWVWVHYDWVWSOSSWSODWVHYDSSDSSDW8"W8"W W W W W W WWWWWWWWWWW6"W6"ST42"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN 10"SAN10"SAN 10" SAN10"SAN10"SAN10"SAN10"ST15"ST15"ST18"ST18"ST18"STST 42"ST 42"ST 42"ST 42"ST 42"ST36"ST36"ST36"STST15"10' PUE BK. 2007 PG. 15339 30' PRIVATE INGRESS/EGRESS EASEMENT BK. 2007 PG. 15333 25' PUBLIC STORM SEWERAND OVERLANDFLOWAGE EASEMENTBK. 2007 PG. 1533715' PRIVATE STORMSEWER EASEMENTBK. 2007 PG. 1533617.5'15' PRIVATE WATER MAIN EASEMENT BK. 2007 PG. 15332 PRIVATE 15'STORM SEWER EASEMENTBK. 2007 PG. 1533623.83'N00°08'00"E7.46'ST48"ST48"ST48"30' PRIVATE INGRESS/EGRESS EASEMENT BK. 2007 PG. 15333 65' PRIVATE OVERLAND FLOWAGE AND DETENTION EASEMENT BK. 2007 PG. 15328 SE STONE RIDGE DRIVESE BRICK DRIVE SE WACO PLACE 7.5' PUBLIC STORM SEWER EASEMENT BK. 2007 PG. 153381.39'62.4'88.34'25' PRIVATE SANITARYSEWER EASEMENTBK. 2007 PG. 1533115'30' PRIVATEINGRESS/EGRESS EASEMENTBK. 2007 PG. 15333LOT 2LOT 3LOT 4LOT 7LOT 6LOT 5SAN 10" ST 42"℄℄℄℄SAN8"SAN8" W6" ST 36"ST 36"ST 36"ST 36"ST 36"ST 36"10281027102610251024 1023102210211031103010291028102710251024102210201031103010291028 1027 1 0 2 6 1 0 2 5 1 0 2 4 10231022102110201019101810171022102310241025102610261025102610241 0 2 3 10221021102010191018101510161 0 1 710171019102010211021102310 2 4 1025 102510241023102210211020101910201023102210211021 102 2WIL L I A M S P O I N T E P L A T 1 4 15' PRIVATESTORM SEWEREASEMENTBK. 2007 PG. 1533610' PUEBK. 2007 PG. 15339W8"1021 1022102310241025 G G G G G G G G G G G GGG GGGGGGGGGGGGGGGGGGGGGG1022.35T/C1021.85G1017.42±EX G1025.24EX±T/C1024.73EX±G1024.64EX± G1017.41±EX±T/C1016.92EX±G1024.92EX±T/C1024.38EX±G1018.66±EX±T/C1018.21EX±G1022.12±EX E/W1022.00±EX E/WMATCH EX WALKPROP. 35'INGRESS/EGRESSEASEMENT59.01'M S00°06'27"E 35.00'MS89°40'04"E59.27'M N00°06'27"W DPROPOSED BUILDING17,089 SFFF = 1023.50868 SF OFFICE16,221 SF MISC. REPAIRHYD WVHYD1020.75T/C1020.25G100YR HWEL=1020.61HPELEV = 1020.701021.20T/C1020.70GOFHP1023.001023.38G1023.25G1023.55T/C1023.05G1023.38G1023.50T/W1023.00G1021.58T/C1021.08G1021.98T/C1021.48G1023.28T/C1022.78G1023.40T/C1022.90G1023.40T/C1022.90G1023.85T/C1023.35G1024.00T/C1023.50G1023.40T/C1023.15G1023.40T/C1023.15G1023.50T/C1023.00G1023.50T/C1023.00GOFHP -REGIONAL DETENTION1024.39T/C1023.89G1023.75T/C1023.25G1024.13T/C1023.63G1023.45T/C1022.95G1023.50T/C1023.00G1023.30T/C1022.80G1024.75T/C1024.25G1024.15G1022.07G1022.15T/C1021.65G1022.60T/C1022.10G1023.00T/C1022.501023.50T/C1023.00G1024.00T/C1023.50G1025.25T/C1024.75G1023.50T/C1023.00G1023.70T/C1023.20G1023.55T/C1023.05G1023.23T/C1022.73G1023.65T/C1023.15G1023.75T/C1023.25G1023.37T/C1022.87G1023.72T/C1023.22G1023.84T/C1023.341023.48T/C1022.98G1023.59T/C1023.09G1023.95T/C1022.45G1022.83T/C1022.33G1022.71T/C1022.21G1022.59T/C1022.09G1023.50T/C1023.00G1023.30T/C1022.80G1023.25T/C1022.75G1023.25T/C1022.75G100YRHWEL=1023.02HPELEV=1023.301023.38G1023.38G1023.501023.50T/C1023.00G1021.75T/C1021.25G100YR HWEL=1021.77HPELEV=1021.75OFHP1020.90T/C1020.40G100YR HWEL=1020.93HPELEV=1020.90OFHP10251023.70T/C1023.20G1 0 2 1 1023.50T/C1023.00G1022.50T/C1022.00GOFHP1022.30T/C1021.80G1022.20T/C1021.70G1022.45T/C1021.95G1023.62T/C1023.12G1023.68T/C1023.18G1023.80T/C1023.30GOFHP1024.00T/C1023.50GWV10211022102 3 1025 1022.15T/C1021.65G100YR HWEL=1021.94HPELEV=1022.001021101810211020101910221021 10201019102310221021102 4 10221023.251022.701023.251023.251022.701023.251023.15T/C1022.65G1022.30PROP. 40'OVERLAND FLOWAGEEASEMENTGM40.00'MN89°41'28"W109.59'M N00°18'32"E 40.00'MS89°47'24"ECO2.00% 1024 102210231023102310232.27%2.00% 1 0 2 2 1023102010191019102010231023 1023 1026 1 0 2 4 102310231023.251021.00T/C1020.50G2.00%2.00%2.00%1022 2.00%4' CURB CUT1023.38G1023.501023.501023.381022.91T/C1023.41G1022.50WWWW W W W W W W U/EU/EU/EU/EU/EU/EU/EU/EU/E U/EU/EU/EU/EU/EU/EU/E U/E U/E U/E U/E U/E U/E U/E U/EW U/E CP #9000CP #9001WVWVWVWVHYDHYDWVWVTDWVHYDWVHYDDDDDDTESELECDHYDHYDWVWVSWSOWVHYDWVWVWVHYDWVWSOSSWSODWVHYDSSDSSDW8"W8"W W W W W W WWWWWWWWWWW6"W6"ST42"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN 10"SAN10"SAN 10" SAN10"SAN10"SAN10"SAN10"ST15"ST15"ST18"ST18"ST18"STST 42"ST 42"ST 42"ST 42"ST 42"ST36"ST36"ST36"STST15"10' PUE BK. 2007 PG. 15339 30' PRIVATE INGRESS/EGRESS EASEMENT BK. 2007 PG. 15333 25' PUBLIC STORM SEWERAND OVERLANDFLOWAGE EASEMENTBK. 2007 PG. 1533715' PRIVATE STORMSEWER EASEMENTBK. 2007 PG. 1533617.5'15' PRIVATE WATER MAIN EASEMENT BK. 2007 PG. 15332 PRIVATE 15'STORM SEWER EASEMENTBK. 2007 PG. 1533623.83'N00°08'00"E7.46'ST48"ST48"ST48"30' PRIVATE INGRESS/EGRESS EASEMENT BK. 2007 PG. 15333 65' PRIVATE OVERLAND FLOWAGE AND DETENTION EASEMENT BK. 2007 PG. 15328 SE STONE RIDGE DRIVESE BRICK DRIVE SE WACO PLACE 7.5' PUBLIC STORM SEWER EASEMENT BK. 2007 PG. 153381.39'62.4'88.34'25' PRIVATE SANITARYSEWER EASEMENTBK. 2007 PG. 1533115'30' PRIVATEINGRESS/EGRESS EASEMENTBK. 2007 PG. 15333LOT 2LOT 3LOT 4LOT 7LOT 6LOT 5SAN 10" ST 42"℄℄℄℄SAN8"SAN8" W6" ST 36"ST 36"ST 36"ST 36"ST 36"ST 36"10281027102610251024 1023102210211031103010291028102710251024102210201031103010291028 1027 1 0 2 6 1 0 2 5 1 0 2 4 10231022102110201019101810171022102310241025102610261025102610241 0 2 3 10221021102010191018101510161 0 1 710171019102010211021102310 2 4 1025 102510241023102210211020101910201023102210211021 102 2WIL L I A M S P O I N T E P L A T 1 4 15' PRIVATESTORM SEWEREASEMENTBK. 2007 PG. 1533610' PUEBK. 2007 PG. 15339W8"1021 1022102310241025 G G G G G G G G G G G GGG GGGGGGGGGGGGGGGGGGGGGG1023.38GREGIONAL DETENTION POND100-YR HWEL = 1020.48HPELEV=1023.00-1023.25100YRHWEL100YRHWEL100YRHWEL100YRHWELHPELEV=1019.24100YR HWEL=1016.801019.24T/C1018.74GOFHP LOT 3 CULVERT1023.25100YRHWEL100YRHWEL=1022.75HPELEV=1023.15100YRHWEL=1022.75HPELEV=1023.15100YRHWELU/EU/EU/EST ST STSAN8"SAN8"ST18"ST18"GG1019.16T/C1018.66G1019.24T/C1018.74G1019.24E/W1019.16E/W1.50%6.25%6.25%1.50%1.50%1.50%40.00'MS89°47'24"EU/EU/EU/EST42"ST42"ST42"SAN8"SAN8"1 0 1 7 GGG1017.91T/C1017.41G1018.02E/W1018.07E/W1017.99E/W1017.94E/W6.63%1.50% 1.50%1.00%1017.99T/C1017.49G6.63%1.50% 1.50%1.00%1.50% 1.50% U/E U/ESDSAN8"SAN8"ST 42"ST 42"STSAN 10" 1021 1021 GGG1020.87 E/W1020.95 E/W1019.81±EX G1020.06±EX G1020.80 E/W1020.88 E/W7.50%0.70%7.50% 1.50% 1.50%2.50% ± EX1019.95 E/W1020.10 E/W1.50%0.70%1021.14±EX T/C1020.75±EX G1021.45±EX T/C1020.92±EX G3.05% ±EX5'10.15'0.17%0.81%U/E U/E U/E U/E SAN 10"SAN 10"1026.23±EX E/W1026.12±EX E/W1026.23T/C1025.73G1026.12T/C1025.62G0.20% EX1.20%1.10% EX1.20%6.25%0.05% EX 6.25%1.20%1.20%U/E U/E U/E U/E SAN 10"SAN 10"1026.22±EX E/W1026.10±EX E/W1026.10T/C1025.60G1026.22T/C1025.72G1026.21±EX E/W5'1026.03±EX E/W1.80%6.25% 1.50%6.25%1.20%1.20%0.20%1.20%U/E U/E U/E U/E SAN 10"SAN 10"D1023.41T/W1022.91G1022.911023.50T/C1023.00T/W1023.501022.641022.641.50%7.31%1.50%1.50%1.50%7.31%0.00%0.00%0.00%0.00%0.00%0.00%1023.00T/C1023.50G1023.41T/C1022.91G0.00%1.50%1.50%1.50%1.50%0.00%0.00%7.31%0.50%10201021.66G1021.72G1022.22 E/W1022.16 E/W1022.10E/W1022.16E/W1.25%1.25%5.97%6.25%1.25%1.25%1.25%1.25%TOPSOIL NOTES:1.THECITY OF WAUKEE UTILIZES SUDAS SECTION 2010 FOR ON-SITE TOPSOILREQUIREMENTS.2.TOPSOIL SHALL BE FREE OF ALL ROCK AND DEBRIS LARGER THAN 3/4" IN SIZE.3.TOPSOIL IS DEFINED AS: FERTILE, FRIABLE LOAM, CAPABLE OF SUSTAININGVIGOROUS PLANT GROWTH, FROM WELL DRAINED SITE FREE FROM FLOODING, NOTIN FROZEN OR MUDDY CONDITIONS; REASONABLE FREE FROM SUBSOIL, CLAYLUMPS, ROOTS, GRASS, WEEDS, STONES LARGER THAN 3/4 INCH IN DIAMETER, ANDFOREIGN MATTER; ACIDITY RANGE (PH) OF 5.5 TO 7.5; CONTAINING MINIMUM 4PERCENT AND MAXIMUM 20 PERCENT ORGANIC MATTER.4.CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING ALL TOPSOILREQUIREMENTS OF NPDES GENERAL PERMIT NO. 2 ARE MET.GRADING PLANC3.1REFERENCE NUMBER:3501 104th Street Des Moines, Iowa 50322-3825 Phone: (515)276-0467 Fax: (515)276-0217 "Planning Your Successful Development" Bishop Engineering Civil Engineering & Land Surveying Established 1959DRAWN BY:CHECKED BY:REVISION DATE:PROJECT NUMBER:SHEET NUMBER:1350 SE STONE RIDGE DRIVE WAUKEE, IOWAMJWCJB3-6-20184-19-20185-3-20185-8-20185-18-20185-23-2018180108PRELIMINARY- NOT FOR CONSTRUCTIONGRAPHIC SCALE040204080GRADING LEGEND:EXISTING CONTOURPROPOSED CONTOURFINISHED GROUND ELEVATIONTOP OF CURB ELEVATIONGUTTER ELEVATIONTOP OF WALK ELEVATIONBOTTOM OF WALL ELEVATIONEDGE OF WALK ELEVATIONTOP OF STAIR ELEVATIONBOTTOM OF STAIR ELEVATIONFLOW DIRECTION & SLOPEOVERFLOW ROUTES100YR HWEL100 YEAR STORM EVENT HIGH WATER ELEVATIONHPELEVCATASTROPHIC OVERFLOW HIGH POINT ELEVATIONNOTE: WALL ELEVATIONS SHOWN ON PLAN ARE FINISHEDGROUND GRADES AT THE TOP AND BOTTOM OF THE WALL.150.50E/W150.50B/W150.50T/W150.50G150.50T/C150.50150150150.50T/S150.50B/SM:\LAND PROJECTS 2018\180108 - STIVERS FORD USED CAR EXPANSION\DWG\C3 GRADING.DWG5/23/2018 2:03:45 PM ADA RAMP GRADING DETAILSRAMP 1RAMP 2RAMPS 3 & 4SCALE = 1:10SCALE = 1:10SCALE = 1:15RAMP 5RAMP 6SCALE = 1:10SCALE = 1:10SCALE = 1:10ADA PARKING GRADING DETAILSRAMP 7SCALE = 1:10ADA RAMP #1ADA RAMP #2ADA RAMP #3&4ADA RAMP #5ADA RAMP #6ADA RAMP #7X.XX% ADJUST STRUCTURE AS NECESSARYMATCH TOP OF SLAB ELEVATIONDPROPOSED BUILDING17,089 SFFF = 1023.50868 SF OFFICE16,221 SF MISC. REPAIRHYDWVHYDINSTALL SALVAGEDFIRE HYDRANT ASSEMBLYTO EXISTING WATER SERVICESTORM STRUCTURE #5SW-505T/C=1021.75GUT=1021.25FL(S)=1017.32100YR HWEL=1021.77STORM STRUCTURE #715" FESFL=1016.6025LF 15" RCP@ S=3.0%RAISE/LOWER RIMAS NEEDEDINSTALL 36± TONSCLASS D/E REVETMENT STONEMINIMUM DIMENSIONST = 1.5', L = 28', W = 12'(SEE DETAIL C7.1)POINT DISCHARGEFOR STORMWATERSTORM STRUCTURE #4SW-505T/C=1020.90GUT=1020.40FL(S)=1017.22100YR HWEL=1020.93STORM STRUCTURE #615" FESFL=1016.6021LF 15" RCP@ S=3.0%STORM STRUCTURE #1SW-502T/C=1020.75GUT=1020.25FL(SW, SE)=1012.21FL(N)=1012.11100YR HWEL=1020.61STORM STRUCTURE #2SW-505T/C=1022.15GUT=1021.65FL(E)=1014.17FL(N)=1013.17100YR HWEL=1021.94STORM STRUCTURE #3SW-501T/C=1023.24GUT=1022.74FL(S)=1014.42FL(N)=1014.32100YR HWEL=1023.02WV97 L F 1 5 " R C P @ S = 1 . 0 0 %27LF 18" RCP@ S= 3.20%CLEANOUTFL=1017.11STORM STRUCTURE #8SW-401 W/DOME INTAKE GRATERIM=1023.40FL(SE)=1013.35FL(NW)=1013.2599LF 15" RCP @ S=1.05%97LF 15" RCP @ S=1.00%60L F 8 " N - 1 2 @ S = 1 . 5 0 %100YR HWEL=1016.80**CRITICAL CROSSING**BOTTOM 15" RCP=1012.78TOP WATER=1011.2575LF 4" PVC SAN. SERV.@ S=2.00% MINREF. MECH. FORCONTINUATIONINSTALL FIRE HYDRANTASSEMBLY PER CITY OFWAUKEE STANDARDSFDC**CRITICAL CROSSING**BOTTOM 15" RCP=1012.45TOP 4" PVC =1010.4557LF 8" N-12 @ S=1.50%NYLOPLAST 8" DRAIN BASINW/DOME GRATERIM=1022.70FL(N)=1016.18NYLOPLAST 8" DRAIN BASINW/DOME GRATERIM=1022.70FL(N)=1015.32R150'REINFORCED CONCRETETRANSFORMER PAD(PER MID-AMERICAN STANDARDS,SEE DETAIL THIS SHEET)GMPROP. 2" VALVE(REF. MECH.)2" 90° BENDPROP. 6" VALVE(REF MECH.)PROP. 6"x2" TEE (REF. MECH.)6" 90° BENDPROP. 136LF GAS SERVICE**BY OTHERS**R150'**CRITICAL CROSSING**BOTTOM 18" RCP=1011.93TOP WATER=1010.40CONNECT TO EX. 8" SAN W/WYE& RISER INV(8")=1006.65±CONTRACTOR TO VERIFY PRIOR TO CONSTRUCTION4" SAN.INV=1016.50CO100YR HWEL= 1017.41SPRINKLER RISER ROOM31LF 8" N-12 @S=1.50%90° N-12 BENDFL=1014.64CO164LF 8" N-12 @S=1.50%WWWW W W W W W W U/EU/EU/EU/EU/EU/EU/EU/EU/E U/EU/EU/EU/EU/EU/EU/E U/E U/E U/E U/E U/E U/E U/E U/EW U/E CP #9000CP #9001WVWVWVWVHYDHYDTBM: ARROW ON HYDRANTELEV=1024.11WVWVTEX INTAKET/C=1017.00FL(S)=1010.82EX INTAKET/C=1017.02DEX STORM MHRIM=1020.92WVHYDTBM: ARROW ON HYDRANTELEV=1020.34WVHYDDEX STORM MHRIM=1017.76DEX STORM MHRIM=1022.35FL(S)=1018.45FL(W)=1018.40FL(E)=1018.25DEX STORM MHRIM=1018.16FL(W)=1012.96FL(SW)=1012.76FL(S)=1012.01FL(E)=1011.94DEX STORM MHRIM=1017.21FL(S)=1011.26FL(W)=1011.03FL(N)=1011.03EX INTAKET/C=1017.01FL(N,S)=1011.02EX INTAKET/C=1016.99EX INTAKET/C=1025.86EX INTAKET/C=1025.88DEX STORM MHRIM=1025.96FL(W)=1021.61FL(NE)=1020.86EX INTAKET/C=1025.94EX INTAKET/C=1025.84FL(E)=1021.78TESEX SAN MHRIM=1026.46INV(E,W)=1009.46ELECDEX STORM MHRIM=1024.91FL(SW)=1020.51FL(E)=1010.28HYDHYD TBM: BURY BOLTELEV=1024.18EX INTAKET/C=1021.42FL(W)=1016.97WVEX INTAKET/C=1024.77FL(E)=10021.37EX INTAKET/C=1024.77WVSEX SAN MHRIM=1026.36EX 15" FESFL=1018.99WSOWVHYDWVWVWVHYDWVW SOSEX SAN MHRIM=1022.87INV(S)=1005.16INV(E,W)=1005.14SEX SAN MHRIM=1021.54INV(N,E,W)=1004.54EX 15" FESFL=1015.76WSOEX 48" FESFL=1016.98DEX STORM MHRIM=1021.96FL(S,N)=1016.56WVHYDSEX SAN MHRIM=1026.10INV(N,S)=1008.05SEX SAN MHRIM=1021.20INV(S)=1001.38INV(W)=1001.20INV(S)=1001.04DEX STORM MHRIM=1022.17FL(E)=1016.47FL(S)=1014.85FL(N)=1014.97EX INTAKET/C=1021.68FL(E)=1017.18FL(W)=1017.15SEX SAN MHRIM=1025.00INV(S)=1007.24INV(W)=UNKNOWNINV(N)=1005.17SEX STORM MHRIM=1024.81FL(S)=1016.70FL(N)=1016.41DEX STORM MHRIM=1024.89FL(N,S)=1019.16EX INTAKET/C=1024.82FL(E,W)=20.89EX INTAKET/C=1024.77EX 15" FESFL=1021.96EX 36" FESFL=1016.64W8"W8"W W W W W W WWWWWWWWWWW6"W6"ST42"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN 10"SAN10"SAN10" SAN10"SAN10"SAN10"SAN10"SAN10"ST15"ST15"ST18"ST18"ST18"STST 42"ST 42"ST 42"ST 42"ST 42"ST36"ST36"ST36"ST36"ST15"10' PUE BK. 2007 PG. 15339 30' PRIVATE INGRESS/EGRESS EASEMENT BK. 2007 PG. 15333 25' PUBLIC STORM SEWERAND OVERLANDFLOWAGE EASEMENTBK. 2007 PG. 1533715' PRIVATE STORMSEWER EASEMENTBK. 2007 PG. 1533617.5'15' PRIVATE WATER MAIN EASEMENT BK. 2007 PG. 15332 PRIVATE 15'STORM SEWER EASEMENTBK. 2007 PG. 1533623.83'N00°08'00"E7.46'ST48"ST48"ST48"30' PRIVATE INGRESS/EGRESS EASEMENT BK. 2007 PG. 15333 65' PRIVATE OVERLAND FLOWAGE AND DETENTION EASEMENT BK. 2007 PG. 15328 SE STONE RIDGE DRIVESE BRICK DRIVE SE WACO PLACE 7.5' PUBLIC STORM SEWER EASEMENT BK. 2007 PG. 153381.39'62.4'88.34'25' PRIVATE SANITARYSEWER EASEMENTBK. 2007 PG. 1533115'30' PRIVATEINGRESS/EGRESS EASEMENTBK. 2007 PG. 15333LOT 2LOT 3LOT 4LOT 7LOT 6LOT 5SAN 10" ST 42"℄℄℄℄SAN8"SAN8" W6" ST 36"ST 36"ST 36"ST 36"ST 36"ST 36"WIL L I A M S P O I N T E P L A T 1 4 15' PRIVATESTORM SEWEREASEMENTBK. 2007 PG. 1533610' PUEBK. 2007 PG. 15339W8"G G G G G G G G G G G G GG GGGGGGGGGGGGGGGGGGGGGGG(GAS PER MAP)UTILITY NOTES:1.ALL PROPOSED UTILTIES SHALL BE PRIVATE, UNLESS NOTED OTHERWISE.2.ALL WATER LINES SHALL HAVE A MINIMUM OF 5.5' OF COVER UNLESS NOTED OTHERWISE.3.FIRE HYDRANT ASSEMBLY SHALL INCLUDE THE TEE, BRANCH, VALVE AND HYDRANT.4.PIPE LENGTHS CALLED OUT ON PLANS INCLUDE FLARED END SECTION, WHERE APPLICABLE.5.STORM SEWER CALLED OUT AS RCP MUST BE CLASS III RCP.6.STORM SEWER CALLED OUT AS N-12 MAY BE EITHER N-12 OR CLASS III RCP.7.FOR RCP PIPE, ASSOCIATED F.E.S. MUST BE RCP. FOR N-12 PIPE, ASSOCIATED F.E.S. SHALL BE CMP.8.TRANSFORMER PAD IS SHOWN FOR REFERENCE ONLY AND MAY NOT BE DRAWN TO ACTUAL SIZE.PAD SHALL CONFORM TO ALL UTILITY COMPANY DESIGN STANDARDS AND SPECIFICATIONS.9.ALL SW-505 & SW-501 STRUCTURES TO USE SW-603 TYPE R CASTINGS.10.ALL ROOF DRAINS TO TIE INTO PROPOSED STORM WATER NETWORK AND WILL NOT DAYLIGHT.UTILITY PLANC4.1REFERENCE NUMBER:3501 104th Street Des Moines, Iowa 50322-3825 Phone: (515)276-0467 Fax: (515)276-0217 "Planning Your Successful Development" Bishop Engineering Civil Engineering & Land Surveying Established 1959DRAWN BY:CHECKED BY:REVISION DATE:PROJECT NUMBER:SHEET NUMBER:1350 SE STONE RIDGE DRIVE WAUKEE, IOWAMJWCJB3-6-20184-19-20185-3-20185-8-20185-18-20185-23-2018180108PRELIMINARY- NOT FOR CONSTRUCTIONGRAPHIC SCALE040204080M:\LAND PROJECTS 2018\180108 - STIVERS FORD USED CAR EXPANSION\DWG\C4 UTILITY.DWG5/23/2018 2:08:12 PM DOWNSPOUT (REF ARCH)4" N-12 PIPEFLOOR SLABPROPOSED GROUNDINSTALL CAP ON STORM PIPE ANDEXTEND DOWNSPOUT INTO CAP COVEREXTERIOR WALLFOUNDATION WALL5' MIN DEPTHDOWNSPOUT CONNECTION DETAILSCALE NONE90° BENDCONNECT TO 8" STORMSEWER W/ WYEREVE7001-110-272DWG NO.1 OF 1SHEET1:16SCALEDWG SIZEA3130 VERONA AVEBUFORD, GA 30518PHN (770) 932-2443FAX (770) 932-2490www.nyloplast-us.com8 IN DRAIN BASIN QUICK SPEC INSTALLATION DETAILTITLEPROJECT NO./NAMEMATERIALDATEREVISED BY11-14-06DATEEBCDRAWN BY03-11-16NMHNYLOPLAST 8" DRAIN BASIN: 2808AG _ _ XTHIS PRINT DISCLOSES SUBJECT MATTER IN WHICHNYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPTOR POSSESSION OF THIS PRINT DOES NOT CONFER,TRANSFER, OR LICENSE THE USE OF THE DESIGN ORTECHNICAL INFORMATION SHOWN HEREINREPRODUCTION OF THIS PRINT OR ANY INFORMATIONCONTAINED HEREIN, OR MANUFACTURE OF ANYARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERSIS FORBIDDEN, EXCEPT BY SPECIFIC WRITTENPERMISSION FROM NYLOPLAST.1 - GRATES/SOLID COVER SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05, WITH THE EXCEPTION OF THE BRONZE GRATE.2 - CUSTOM DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS. RISERS ARE NEEDED FOR BASINS OVER 84" DUE TO SHIPPING RESTRICTIONS. SEE DRAWING NO. 7001-110-065.3 - STANDARD DRAIN BASIN HAS FIXED ADAPTER LOCATIONS OF 0° & 180°. CUSTOM DRAIN BASIN ADAPTERS CAN BE MOUNTED ON ANY ANGLE 0° TO 360°. TO DETERMINE MINIMUM ANGLE BETWEEN ADAPTERS SEE DRAWING NO. 7001-110-012.4 - FOR COMPLETE DESIGN DETAILS SEE DRAWING NO. 7001-110-045.5 - DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO ASTM D3212 FOR CORRUGATED HDPE (ADS N-12/HANCOR DUAL WALL) & PVC SEWER (4" - 24").(4)(4)4" MINWATERTIGHT JOINT(CORRUGATED HDPE SHOWN)(5) VARIOUS TYPES OF INLET & OUTLET ADAPTERS AVAILABLE:4" - 8" FOR CORRUGATED HDPE (ADS N-12/HANCOR DUAL WALL,ADS/HANCOR SINGLE WALL), PVC SEWER (EX: SDR 35), PVC DWV(EX: SCH 40), PVC C900/C905, CORRUGATED & RIBBED PVCTHE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHERGRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS I,CLASS II, OR CLASS III MATERIAL AS DEFINED IN ASTM D2321.BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BEPLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321.(1) DUCTILE IRON GRATEOPTIONAL CONCRETE POUR RING(FOR USE IN SIDEWALK/DECK APPLICATIONS)CONCRETE WALKWAY OR DECK®©2013 NYLOPLASTTRANSFORMER PAD MOAT DETAILNOT TO SCALEREINFORCED CONCRETETRANSFORMER PAD (PERMID-AMERICAN STANDARDS)REFERENCE ELECTRICAL PLANSTRANSFORMER3'3'3'3'3" RIVER ROCK,SCREENEDDURAEDGE 1/8"STEEL EDGING,COLOR GREENREINFORCED CONCRETETRANSFORMER PAD (PERMID-AMERICAN STANDARDS)3" RIVER ROCK,SCREENED3'2'2'3'LINE TRENCH WITH SILT FENCEFABRIC (OR OTHER SOIL FABRICWITH EQUAL OR LOWERPOROSITY)DURAEDGE 1/8"STEEL EDGING,COLOR GREEN PROP. 35'INGRESS/EGRESSEASEMENT59.01'M S00°06'27"E 35.00'MS89°40'04"E59.27'M N00°06'27"W DPROPOSED BUILDING17,089 SFFF = 1023.50868 SF OFFICE16,221 SF MISC. REPAIRHYDWVHYD 1025 1 0 2 1 WV10211022102 3 1025 1021101810211020101910221021 10201019102310221021102 4 1022PROP. 40'OVERLAND FLOWAGEEASEMENTGM40.00'MN89°41'28"W109.59'M N00°18'32"E 40.00'MS89°47'24"ECO1024 102210231023102310231 0 2 2 1023102010191019102010231023 1023 1026 1 0 2 4 102310231022 U/EU/EU/EU/EU/EU/EU/EU/EU/E U/EU/EU/EU/EU/EU/EU/EU/EU/EU/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E U/E WVWVHYDHYDWVWVTDWVHYDWVHYDDDDD4" TREE4" TREE4" TREE4" TREE4" TREE4" TREE4" TREE4" TREE4" TREEWVSSSWSODSSDSSDW8"W8"W8"WWWWWWWWWWW6"ST42"S T SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN10"SAN 10"SAN10"SAN 10" SAN 10"SAN 10"SAN 10"SAN 10"SAN10"ST18"ST18"ST18"ST18"ST 42"ST 42"ST 42"ST 42"ST 42"ST 42"ST36"ST36"ST36"ST36"ST36"ST15"23.83'N00°08'00"EST15"SE STONE RIDGE DRIVESE WACO PLACE LOT 3LOT 4LOT 6LOT 5SAN10"SAN 10"℄℄℄SAN 8" W6" ST 36"ST 36"ST 36"ST 36"ST 36"ST 36"ST 36"ST 36"ST 36"102610251024 10231022102110221020 1 0 2 6 1 0 2 5 1 0 2 4 1023102210211020101910181017102210231024102510261026102510241 0 2 3 10221021102010191018101510161 0 1 7101710191020102110211025102410231022102110201019 1021 102 2WIL L I A M S P O I N T E P L A T 1 4 W8"W8"1021 1022102310241025 GGGGGGGGGGGGGGGGGGRB6GB3ER2PF1GB1EDGINGSH3GB1GL4GL4GB2GL6GB2GL19AL3SH1SH1GL2WO1CS2AL1ER1PV5CV6KF15KF18KF3AL1PF1CS3BH2PF1SS3PF1SH5LANDSCAPE NOTES:1.ALL SODDING & LANDSCAPE PLANTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE URBAN STANDARD SPECIFICATIONS, UNLESS SPECIFIED OTHERWISE.2.SOD ALL DISTURBED AREAS WITHIN THE CONTRACT LIMITS UNLESS NOTED OTHERWISE. .3.PLANT QUANTITIES ARE FOR CONTRACTORS CONVENIENCE, THE DRAWING SHALL PREVAIL IF A CONFLICT OCCURS.4.ALL PLANT MATERIAL SHALL CONFORM TO THE LATEST EDITION OF THE AMERICAN STANDARD FOR NURSERY STOCK (ANSI Z60.1).5.CONTRACTOR SHALL GUARANTEE ALL PLANT MATERIAL FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE.6.IT IS THE CONTRACTORS RESPONSIBILITY TO REMOVE IDENTIFICATION TAGS AND CORDS ON ALL PLANT MATERIAL PRIOR TO THE COMPLETION OF THE CONTRACT.IDENTIFICATION TAGS MUST BE LEFT ON UNTIL AFTER ACCEPTANCE BY OWNER OR OWNER'S REPRESENTATIVE.7.CONTRACTOR SHALL PLACE SHREDDED HARDWOOD MULCH AROUND ALL TREES, SHRUBS AND GROUND COVER BEDS TO A DEPTH OF 4 INCHES, UNLESS NOTED. DO NOTPLACE MULCH AROUND PLANTS WITHIN ROCK LANDSCAPE BEDS.8.STAKE AND WRAP ALL DECIDUOUS TREES IMMEDIATELY AFTER PLANTING. STAKE ALL TREES ACCORDING TO THE STAKING DETAILS. CONTRACTOR SHALL ADJUST ANDMAINTAIN GUYING TENSION THROUGHOUT THE PLANT ESTABLISHMENT PERIOD.9.THE LANDSCAPING CONTRACTOR SHALL HAVE ALL UTILITIES LOCATED BEFORE STARTING ANY SITE WORK OR PLANTING. THE CONTRACTOR SHALL BE RESPONSIBLE FORTHE PROTECTION OF ALL EXISTING UTILITIES.10.NO LANDSCAPE MATERIAL SHALL BE SUBSTITUTED WITHOUT THE AUTHORIZATION OF THE LANDSCAPE ARCHITECT.11.CONTRACTOR SHALL BE RESPONSIBLE MAINTAINING APPROPRIATE LEVEL OF WATERING FOR ALL NEW PLANTS FOR A PERIOD OF 30 DAYS.12.ALL EDGING SHALL BE DURAEDGE 1/8" STEEL EDGING - COLOR GREEN, OR APPROVED EQUAL13.ALL SHRUB AND PERENNIAL PLANTING BEDS SHALL INCORPORATE TYPAR 3301 NONWOVEN LANDSCAPE FABRIC (OR SIMILAR) AND 3" THICK LAYER OF WASHED RIVERROCK (1.5" NOMINAL SIZE).14.ALL BEDS TO RECEIVE GRANULAR PRE-EMERGENT WEED CONTROL BEFORE AND AFTER ROCK IS INSTALLED.LANDSCAPE PLANC5.1REFERENCE NUMBER:3501 104th Street Des Moines, Iowa 50322-3825 Phone: (515)276-0467 Fax: (515)276-0217 "Planning Your Successful Development" Bishop Engineering Civil Engineering & Land Surveying Established 1959DRAWN BY:CHECKED BY:REVISION DATE:PROJECT NUMBER:SHEET NUMBER:1350 SE STONE RIDGE DRIVE WAUKEE, IOWAMJWCJB3-6-20184-19-20185-3-20185-8-20185-18-20185-23-2018180108PRELIMINARY- NOT FOR CONSTRUCTIONGRAPHIC SCALE030153060DO NOT CUT CENTRAL LEADERWRAP TRUNK WITH APPROVEDTREE WRAP TO FIRST BRANCH4" DEEP HARDWOOD MULCHCUT SYNTHETIC CORDS AROUNDROOTBALL AND TRUNK -ENTIRELYREMOVE WIRE BASKETS FROM BALLSET ROOTBALL ON UNDISTURBEDSUBGRADEDECIDUOUS TREE PLANTING (TYP.)NOT TO SCALESCALE:SCARIFY SIDES & BOTTOM OFPLANTING PITSTAKING ORIENTATIONNORTHNORTH2 STAKES - 3" CAL. & LESS3 STAKES - GREATER THAN 3" CAL.3'-0"SET ROOTBALL FLUSH WITHFINISHED GRADEDO NOT PLACE MULCH INCONTACT WITH BASE OF TREEPRUNE ANY DEAD/DAMAGEDBRANCHING FROM TREE.MAINTAIN OVERALL APPEARANCE.USE HOSE GUARDS AROUNDTRUNK ON STAKING WIRE. TIEWIRE TO STEEL POSTS PLACEDOUTSIDE PLANT PIT..LEAVE STAKES IN PLACE NO MORETHAN 1 YEAR FROM INSTALLATION.CONTRACTOR RESPONSIBLE FORREMOVAL.4" DEPTH SHREDDED HARDWOODMULCHSCARIFY SIDES & BOTTOM OFPLANTING PITEVERGREEN TREE PLANTING (B&B)NOT TO SCALESCALE:CUT SYNTHETIC CORDS AROUNDROOTBALL AND TRUNK -ENTIRELYREMOVE WIRE BASKETS FROM BALLSET ROOTBALL ON UNDISTURBEDSUBGRADE3'-0"DO NOT PLACE MULCH INCONTACT WITH BASE OF TREEDECIDUOUS SHRUB DETAILEVERGREEN SHRUB DETAILPLANTING ON SLOPESFIRMLY COMPACT SAUCER(USE TOPSOIL)ORIGINAL GROUND LINESUB-SOIL4" MULCHPLANTING PIT TWICETHE WIDTH OF ROOTBALL12SHRUB PLANTING (TYP)NOT TO SCALESCALE:M:\LAND PROJECTS 2018\180108 - STIVERS FORD USED CAR EXPANSION\DWG\C5 LANDSCAPE.DWG5/23/2018 2:09:38 PM 3" ROCKGENERAL LANDSCAPE REQUIREMENTSTOTAL SQUARE FOOTAGE OF PROJECT AREA165,249 SFREQUIRED OPEN SPACE(20%)33,050 SFGENERAL OPEN SPACE REQUIREMENTTOTAL REQUIRED TREES (1 PER 1000 SF OF REQUIRED OPEN SPACE34 50% MUST BE OVER STORY TREES17 MINIMUMTOTAL REQUIRED SHRUBS (1 PER 1000 SF OF REQUIRED OPEN SPACE)34INTERIOR PARKING REQUIREMENTTOTAL REQUIRED TREES (1 PER ISLAND)5 TOTAL PROPOSED 5PARKING PERIMETER (SE STONE RIDGE DRIVE)TOTAL LENGTH OF LOT108 LNFTTOTAL REQUIRED TREES (1 PER 40 LNFT)3DO NOT CUT CENTRAL LEADERPLANTING SCHEDULENOTE: AT TIME OF PLANTING OVERSTORY TREES MUST BE A MINIUMUM OF 8' HEIGHT, EVERGREEN TREES MUST BE A MINIMUM OF 6' HEIGHT. 5" PCC SIDEWALK59.01'M S00°06'27"E 35.00'MS89°40'04"E59.27'M N00°06'27"W DREFUSE ENCLOSUREREF. ARCH. FOR DETAILPROPOSED BUILDING17,089 SFFF = 1023.50868 SF OFFICE16,221 SF MISC. REPAIRHYD WVHYD SFSFROCKED CONSTRUCTIONENTRANCE & STAGINGDUMPSTER, OUTHOUSE &CONTAMINANT CONTAINMENT DEVICEINLET PROTECTION (TYP.)SFSFSFSFDISTURBANCELIMITDISTURBANCELIMITBELOW GRADEINLET PROTECTION (TYP.)BELOW GRADEINLET PROTECTION (TYP.)BELOW GRADEINLET PROTECTION (TYP.)INSTALL 25± TONSCLASS D/E REVETMENT STONEMINIMUM DIMENSIONST = 1.5', L = 28', W = 12'(SEE DETAIL THIS SHEET)**POINT DISCHARGE TOREGIONAL DETENTION,ULTIMATE DISCHARGETO WALNUT CREEK**1025 1 0 2 1 WV10211022102 3 1025 1021101810211020101910221021 10201019102310221021102 4 1022TOPSOILSTOCKPILESFSFSFSFSFSFSFSFSFSFS F SFSFSFSFSF SF SF SF SF SF SF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFGM40.00'MN89°41'28"W109.59'M N00°18'32"E 40.00'MS89°47'24"ECODISPLAY LOT PARKINGDISPLAY LOT PARKINGDISPLAY LOT PARKING**POINT DISCHARGE W/ULTIMATE DISCHARGETO WALNUT CREEK**1024 102210231023102310231 0 2 2 1023102010191019102010231023 NO CURB ONWEST EXTENTOF SLAB1023 1026 1 0 2 4 102310231022 4' CURB CUT8" PCC8" PCC7.5" PCC6.5" PCC7.5" PCC7.5" PCC7.5" PCC7.5" PCC7.5" PCC7.5" PCC6.5" PCC6.5" PCC6.5" PCC6.5" PCC6.5" PCC6.5" PCC6.5" PCC5'x5' STRUCTURALSTOOP (REF. ARCH.)5'x5' STRUCTURALSTOOP (REF. ARCH.)TAPER CURBU/EU/EU/EU/EU/EU/EU/EU/EU/EU/EU/EU/E U/E U/E U/E U/E U/E U/E U/E U/EW U/E WVWVWVHYDHYDWVWVTWVHYDWVHYDDDDHYDHYDWVWVSWSOSSWSODWVHYDSSDSSDW8"W8"W W W W W W WWWWWWWWWW6"W6"ST42"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN8"SAN 10"SAN 10"SAN 10" SAN10"SAN10"SAN10"SAN10"SAN10"ST15"ST18"ST18"ST18"ST 42"ST 42"ST 42"ST 42"ST 42"ST36"ST36"ST36"ST36"ST15"10' PUE BK. 2007 PG. 15339 30' PRIVATE INGRESS/EGRESS EASEMENT BK. 2007 PG. 15333 25' PUBLIC STORM SEWERAND OVERLANDFLOWAGE EASEMENTBK. 2007 PG. 1533715' PRIVATE STORMSEWER EASEMENTBK. 2007 PG. 1533617.5'15' PRIVATE WATER MAIN EASEMENT BK. 2007 PG. 15332 PRIVATE 15'STORM SEWER EASEMENTBK. 2007 PG. 1533623.83'N00°08'00"E7.46'48"65' PRIVATE OVERLAND FLOWAGE AND DETENTION EASEMENT BK. 2007 PG. 15328 SE STONE RIDGE DRIVESE WACO PLACE62.4'88.34'25' PRIVATE SANITARYSEWER EASEMENTBK. 2007 PG. 1533115'30' PRIVATEINGRESS/EGRESS EASEMENTBK. 2007 PG. 15333LOT 2LOT 3LOT 4LOT 7LOT 6LOT 5SAN 10"℄℄℄SAN 8" W6" ST 36"ST 36"ST 36"ST 36"ST 36"ST 36"10281027102610251024 102310221021102210201029102810271026102510241023102210211020101910181017 10221023102410251026102610251026102510241 0 2 3 10221021102010191018101510161 0 1 7101710191020102110211023102510241023102210211020101910251020 1020 102 5 1023102210211021 102 2 15' PRIVATESTORM SEWEREASEMENTBK. 2007 PG. 15336W8"1021 1022102310241025 GGGGGGGGGGGGGGGGGGGGG6SITESWPPPC7.1REFERENCE NUMBER:3501 104th Street Des Moines, Iowa 50322-3825 Phone: (515)276-0467 Fax: (515)276-0217 "Planning Your Successful Development" Bishop Engineering Civil Engineering & Land Surveying Established 1959DRAWN BY:CHECKED BY:REVISION DATE:PROJECT NUMBER:SHEET NUMBER:1350 SE STONE RIDGE DRIVE WAUKEE, IOWAMJWCJB3-6-20184-19-20185-3-20185-8-20185-18-20185-23-2018180108PRELIMINARY- NOT FOR CONSTRUCTION GRAPHIC SCALE040204080PROPERTY DESCRIPTION:QUIT CLAIM DEED BOOK: 2015 PAGE: 20587LOT 4, 5, AND 6, IN WILLIAMS POINT PLAT 14, AN OFFICIAL PLAT, NOW INCLUDED IN AND FORMING A PART OFTHE CITY OF WAUKEE, DALLAS COUNTY, IOWA.SAID TRACT OF LAND SUBJECT TO ALL EASEMENTS AND ENCUMBRANCES OF RECORD.SAID TRACT OF LAND CONTAINS 3.79 ACRES MORE OR LESS.ADDRESS:1350 SE STONE RIDGE DRIVEWAUKEE, IOWA 50263OWNER:STIVERS IOWA REAL ESTATE LLC1450 EAST HICKMAN ROADWAUKEE, IOWA 50263BENCHMARK:CP #9000:NE CORNER OF SE STONE RIDGE DRIVE & SE WACO PLACE3/4" IRON PIPE W/RPC N=588190.02E=1545997.53ELEV=1020.98'CP#9001:NE CORNER OF SE STONE RIDGE DRIVE & SE BRICK DRIVE3/4" IRON PIPE W/RPCN=588182.14E=1545278.84ELEV=1024.61'LIMIT OF DISTURBANCE CALCULATION:TOTAL DISTURBANCE AREA = 183,500 SF (4.21 ACRES)STORM WATER POLLUTION PREVENTION PLANVICINITY MAPNOT TO SCALEIOWAONE CALL1-800-292-8989www.iowaonecall.com811Know what's below. Call before you dig.UTILITY NOTE:THE LOCATION OF THE UTILITIES INDICATED ON THE PLANS ARE TAKEN FROMEXISTING PUBLIC RECORDS AND ARE APPROXIMATE LOCATIONS. THE EXACTLOCATIONS OF ALL UTILITIES MUST BE ASCERTAINED IN THE FIELD. IT SHALL BETHE DUTY OF THE CONTRACTOR TO DETERMINE WHETHER ANY ADDITIONALFACILITIES OTHER THAN THOSE SHOWN ON THE PLANS MAY BE PRESENT.EROSION CONTROL NOTES:1.SITE NPDES GENERAL PERMIT #2 AUTHORIZATION NUMBER: 31743-31455.2.SEE SUPPLEMENTAL DETAIL STORM WATER POLLUTION PLAN NARRATIVEFOR ALL EROSION CONTROL MEASURES, ADDITIONAL DETAILS AND NOTE.ADDITIONAL NOTES AND MEASURES IN NARRATIVE SHALL BE CONSIDEREDINCIDENTAL AND SHALL BE INCLUDED IN THE ORIGINAL BID.3.SWPPP PLAN AND NARRATIVE ARE CONSIDERED A LIVING DOCUMENT ANDWILL NEED PERIODIC UPDATES AND ADJUSTMENTS AS NECESSARYDEPENDING ON SITE CONDITIONS TO ASSURE COMPLIANCE WITH NPDESGENERAL PERMIT NO. 2. IT IS THE CONTRACTOR'S RESPONSIBILITY TOUPDATE THE SWPPP AND IMPLEMENT ANY AND ALL MEASURES NECESSARYTO COMPLY WITH SAID PERMIT NO. 2.4.INSTALL PERIMETER SILT FENCE AS SHOWN ON PLANS PRIOR TOCONSTRUCTION.5.INSTALL INTAKE PROTECTION WITH SILT FENCE IMMEDIATELY AFTER STORMSEWER CONSTRUCTION.6.INSTALL FINISHED PAVING INLET PROTECTION IMMEDIATELY AFTER PAVINGIS COMPLETED AROUND INTAKE.7.OTHER EROSION CONTROL TYPES MAY NOT BE SUBSTITUTED FOR SILTFENCE.8.CONTRACTOR SHALL BE RESPONSIBLE FOR SUPPLYING A CONCRETEWASHOUT IN ACCORDANCE WITH NPDES GENERAL PERMIT NO. 2 DURING ALLCONCRETE WORK. REFERENCE SUDAS 11050 FOR WASHOUTSPECIFICATIONS.9.CONTRACTOR SHALL BE RESPONSIBLE FOR SUPPLYING TEMPORARYRESTROOM FACILITIES. SANITARY WASTE SHALL BE DISPOSED OF PER ALLFEDERAL, STATE AND LOCAL REGULATIONS.10.CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING ALL TOPSOILREQUIREMENTS OF NPDES GENERAL PERMIT NO. 2 ARE MET.11.CONTRACTOR TO PROTECT STORM SEWER AND DRAINAGE WAYS FROMSLURRY DISCHARGE DUE TO CONCRETE SAWCUTTING AND/OR CONCRETEGRINDING PER THE NPDES GENERAL PERMIT NO. 2.EROSION CONTROL REMOVAL NOTES:1.AFTER FINAL STABILIZATION HAS OCCURED, AS DEFINED IN NPDES GENERALPERMIT NO. 2, CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OFALL TEMPORARY EROSION CONTROL DEVICES INCLUDING, BUT NOT LIMITEDTO: SILT FENCE, INLET PROTECTION, AND TEMPORARY STANDPIPES.LEGEND: 120 EXISTING CONTOUR 120 PROPOSED CONTOUR SF SILT FENCE SAN SANITARY SEWER ST STORM SEWER W WATER LINE G GAS LINEU/E UNDERGROUND ELECTRICO/E OVERHEAD ELECTRICTELETELEPHONE LINEF/OFIBER OPTICCATVCABLE TVSTORM MANHOLECURB INTAKESURFACE INTAKEFLARED END SECTIONSANITARY MANHOLECLEANOUTFIRE HYDRANTSPRINKLERIRRIGATION CONTROL VALVEWATER MANHOLEWELLWATER VALVEWATER SHUT OFFYARD HYDRANTELECTRIC MANHOLEELECTRIC METERELECTRIC RISERELECTRIC VAULTPOWER POLETRANSFORMER POLELIGHT POLEELECTRIC JUNCTION BOXELECTRIC PANELTRANSFORMERGROUND LIGHTGUY WIREELECTRIC HANDHOLEGAS METERGAS VALVEAIR CONDITIONING UNITTELEPHONE RISERTELEPHONE VAULTTELEPHONE MANHOLETRAFFIC SIGNAL MANHOLEFIBER OPTIC RISERFIBER OPTIC FAULTCABLE TV RISERSIGNDSCOHYD I CVWWSOYADREEMEELECEJEPGMGVA/CTTELTTSFOF/OTVWWVNOT TO SCALESITE ENTRANCE DETAILTEMP. ROCK ENTRANCE(PLAN VIEW)(PROFILE VIEW)TEMP. ROCK ENTRANCE3" CLEANLIMESTONEPLACE ROCKON FABRICSTABILIZED ENTRANCE SHALL BE ATLEAST 50' LONG AND EXTEND TO THEPUBLIC ROADWAY.5'-0" MIN.GROUND LINEENGINEERING FABRICFLOW21' ABOVE GROUND LINEVARIABLE10' MAX.5' MAX.5' MAX.10' MAX.1' ABOVE GROUND LINESECURE TOP OF ENGINEERING FABRICENGINEERING FABRIC TO BE PLACEDTO BOTTOM OF TRENCH. 12ENGINEERINGFABRICGROUNDLINETRENCH BOTTOMTRENCH BOTTOM111LINEGROUND1MIN.4"EXCESS FABRICCOMPACTED BACKFILL12"MIN.DETAIL OF SILT FENCE AT DITCH OR SWALEDETAIL OF SILT FENCE8' SPACINGTO TOP OF STEEL POST.SEE DETAIL OF ATTACHMENT TO POST.VERTICAL CUTWIRECORDCORDCORDWIREPOSTFABRICFABRICBACK VIEW OF FABRICBACK VIEWATTACHMENT TO POST34NOTES :3MAKE VERTICAL CUT IN TOP OF FABRIC.PULL OUT AND TWIST CORD.4LOOP CORD AROUND POST FORMING ALOOP. PULL WIRE THROUGH FOLD AREAOF FABRIC AND SECURE AROUND POST.'T' STEELFENCE POSTNORMALFORESLOPE2" RISEIN FENCE31"MIN.NORMAL BACKSLOPE31" MIN.6" TRENCH DEPTH FORNORMAL INSTALLATION(MIN.) 12" TRENCHDEPTH FOR DITCHINSTALLATIONNOT TO SCALE(SECTION VIEW)(PROFILE VIEW)SILT FENCE DETAILSNOT TO SCALEINLET5'-0"5'-0"'T' FENCE POST, 5' MIN.NOTES:1. SECURE TOP OF FABRIC TOPOSTS, USING CABLE TIES ORWIRE.2. FABRIC TO BE BURIED 12", ANDFOLDED ALONG BOTTOM.3. STEEL POSTS TO BE EMBEDDED28".(PLAN VIEW)DROP INLET BASKETPROTECTIONSILT FENCE FABRICIF APPLICABLEINLET PROTECTION DETAILNOT TO SCALENOTES:1. 1 C.Y. CONCRETE BAG SHALL BE REQUIRED AT ANYLOCATION WHERE CONCRETE IS USED.2. CONCRETE WASHOUT DUMPSTER W/ HEAVY DUTYLINER IS AN ACCEPTIBLE ALTERNATIVE(PLAN VIEW)1 C.Y. CONCRETEWASH-OUT BAG'T' FENCE POST5' MINCONCRETE WASH-OUT BAG DETAIL(PROFILE VIEW)1 C.Y. CONCRETEWASH-OUT BAGRIP RAP @ FES OUTFALL DETAILNOT TO SCALEM:\LAND PROJECTS 2018\180108 - STIVERS FORD USED CAR EXPANSION\DWG\C7 SWPPP.DWG5/23/2018 2:10:20 PM SEDIMENT CONTROL SCHEDULE:1.NOTE: SCHEDULE FOR BID ONLY. ACTUAL SITE CONDITIONS WILL DICTATEQUANTITIES AS THE SWPPP IS A LIVING DOCUMENTSILT FENCE/WATTLE= 1,700LFBELOW GRADE INTAKE BASKETS= 6CONSTRUCTION ENTRANCE RIP RAP= MIN 125 TONSFES OUTFALL RIP RAP= MIN. 25 TONSSOD= APPROX. 36,000 SFTEMP. STABALIZATION -MULCH OR TYPE 4 SUDAS SEED/MULCH= APPROX 36,000 SF Level 1 0" 123 4 5 6 789 4 10 29'-6 1/2" Level 1 0" LOW EAVE - TOP OF FRAME 19' - 4" 1/4" 1'-0" 1 2 3 4 5 6 9 78 11 . 19'-9"10'-0"IT: INSULATED TEMPERED GLASS (U VALUE LESS THAN 0.26) OHD: SEE SHEET A600 ITLE: 1" INSULATED TEMPERED LOW E GLASS ( U VALUE LESS THAN 0.31) T: TEMPERED GLASS GLAZING Level 1 0" LOW EAVE - TOP OF FRAME 19' - 4" 23 4 8 10 DS DSDSDSDSDS 1514 Level 1 0" LOW EAVE - TOP OF FRAME 19' - 4" 1/4" 1'-0". . 11 11 12 2 3 79 13 MARCROPOXY PAINT ON DOOR & FRAME DESCRIPTIONISSUE #ISSUE DATE NBI #: 17-1-734DBS #: 17-3-152 DESCRIPTIONISSUE #ISSUE DATE 1 GENERAL CONTRACTOR - ARCHITECT 1435 ohio street/p.o. box 1315 / des moines, ia 50305-1315 phone: (515) 243-0156 / fax: (515) 243-0165 NEUMANN BROTHERS, INC. - DESIGNBUILD SOLUTIONS 1 A 02/24/18 BUDGET SETSTIVERS FORD MERCURY 2 3 4 5 6 7 8 B C D E REVIEW SET 2 03/05/18 BUDGET SET 3 04/18/18 REVIEW SET A200 EXTERIOR ELEVATIONS AUTO BODY BUILDING WAUKEE, IOWA 1/8" = 1'-0"A200 A2 EAST 1/8" = 1'-0"A200 C2 NORTH 1/8" = 1'-0"A200 D2 WEST 1/8" = 1'-0"A200 E2 SOUTH ELEVATION KEYNOTES MARK DESCRIPTION 1 DRAINABLE EIFS SYSTEM; 2.5" THICK; CONTROL JOINTS LOCATED AS SHOWN 2 3" THICK X 36" WIDE INSULATED METAL WALL PANEL W/ 1/2" REVEAL - SMOKE GRAY : EQ. TO METAL SPAN SMOOTH FACED DW-4000 W/ KYNAR FINISH AND MAX U-VALUE OF 0.048 3 3" THICK X 36" WIDE INSULATED METAL WALL PANEL W/ 1/2" REVEAL - REGAL GRAY TO SMOOTH FACED METL-SPAN DW-4000 W/ KYNAR FINISH & MAXIMUM U-VALUE OF 0.048 4 CORRUGATED METAL WALL PANEL - PACIFIC BLUE EQ. TO METL-SPAN 7.2 PANEL 5 CLEAR ANODIZED THERMAL BREAK STOREFRONT WITH 1" LOW E INSULATED GLASS EQUAL TO KAWNEER 600 SERIES - U-VALUE OF GLAZING: 0.30 OR LOWER 6 MODULAR BRICK: CAPITAL IRONSPOT VEL, YANKEE HILL BRICK TILE W/ G602 GLEN-GERY COLORED MORTAR 7 INSULATED HOLLOW METAL OVERHEAD DOOR W/ INSULATED GLASS TOP PANEL AND FACTORY FINISHED GREY COLOR . 8 BOLLARD: 6" DIA GALV. STEEL BOLLARD, CONCRETE FILLED, PAINTED AND MOUNTED TO BUILDING FOOTING BELOW 9 CONCRETE INSULATED PANEL (WALLGUARD BY T-CLEAR OR EQUAL), PAINT 10 COLORED SPLIT FACE CONCRETE BLOCK W/ COLORED MORTAR 11 SCREEN WALL AT ROOF: PACIFIC BLUE METL SPAN 7.2 PANEL 12 DUMPSTER GATE: COMPOSITE WOOD VERTICAL SLATES - STAINED & SEALED - ON METAL FRAMING MOUNTED ON CONCRETE FILLED 6" GALVANIZED STEEL POST 13 RAKE FLASHING BY METAL BUILDING MFR. 14 PRE-FINISH ROOF GUTTER BY METAL BUILDING MFR. 15 PREFINISHED METAL DOWNSPOUT BY METAL BULDG. MFR. - CONNECTED TO SUBSURFACE DRAINAGE # GENERAL NOTES: 1) ALL WALLS ARE TYPE 1 UNLESS NOTED OTHERWISE. 2) " " INDICATES WINDOW UNIT; SEE WINDOW SCHEDULE FOR SIZES & DETAIL REFERENCES. A200 A2 A200 D2 A200C2 17,460 GSF ALUMINUM A200 E2 654 3 3 2 2 7 81 WORK STATIONS - (12 STALLS) WASH WORK STATIONS - (8 STALLS) UNDERCOATING DETAIL STORAGE/BULK TOOLS 103 HALLWAY 109 INSURANCE 111 METAL REPAIR 102 FRAME 180'-0" 25'-0"25'-0"25'-0"25'-0"25'-0"25'-0"30'-0"29'-0"39'-8"28'-4"INSPECTION 104 23'-4" OFFICE 110 INSURANCE 112 RECEPTION 106 WOMEN 107 MEN 108 WAITING 105 FINISHES 101 A1 A300 E1 A401 7'-1" 4 7/8" 7'-1" 24 LOCKERS E5 A401 E1 A400 E4 A400 E7 A400 E6 A400 E4 A401 CONTROL PANEL CONTROL PANEL CONTROL PANEL - NEW LOCATION CONTROL PANEL A BB4'-5"3'-9 5/8"105A 102F 105B 101D 103B 103A 101F 101G 109 103C 104B 112 111 110 107108 102E 102D 104A 102C102B102A101C 113 101E 51'-9"18'-0" 6'-9" 18'-0" 7'-0" 18'-0" 7'-0" 18'-0"15'-2" 8'-0" 12'-4" ACCEPTABLE LOCATION PORTAL FRAME 1'-6"1'-6" 1'-0" 1'-6"9'-8" 1'-9" 1'-0" 20'-9"13'-8" 1'-0" 4'-4" ACCEPTABLE LOCATION X-BRACE 1'-6"1'-6"1'-6"8"3'-2"29'-9"12'-0"4'-6 1/2"18'-0"13'-0"19'-8 1/2"10'-8"7'-8"34'-8"3'-4"A141 E7 10" 10'-4"35'-2"18'-0"38'-8"3'-8"97'-0"97'-0"8"E1 A30028'-3 1/2" 4'-9 1/8" BEAMS BY PRE-ENGINEERED BUILDING TO CARRY POINT LOADS AS NOTED. - TOP OF BEAM TO BE 6" BELOW TOP OF BUILDING FRAMES 1000 LBS 1000 LBS 1000 LBS 1000 LBS 1000 LBS 1000 LBS 1000 LBS2"1000 LBS 1" GIRTS AT MASONRY AT 2'-0" V.O.C. E2 A400 A140 E3 E7 A401 38'-8"8" E4 A401 Sim E3 A401 A140 C7 LOCKER 11330'-0"COLUMN COLUMN 2'-4" DEEP PIT 2'-4" DEEP PIT 3'-0" DEEP PIT GRATE BY BOOTH VENDOR STEGO LINER BELOW PIT FIRE EXTINQUISHER ON BRACKET FIRE EXTINQUISHER ON BRACKET 10'-9 1/8"6'-11 1/4" A600 D5 A600C5 GRATE BY BOOTH VENDOR 400 LBS 400 LBS 300 LBS 400 LBS 400 LBS 300 LBS BEAMS BY PRE-ENGINEERED BUILDING TO CARRY POINT LOADS AS NOTED. - TOP OF BEAM TO BE 6" BELOW TOP OF BUILDING FRAMES. VERIFY LOADS W/ MECH. COLUMN COLUMN 5'-4" 12'-0" 11'-11"34'-5"12'-10" 18'-0" 7'-0"43'-0"6'-0"29'-6" DETAILING PRE-ENGINEERED BUILDING NOTES 1. METAL BUILDING MANUFACTURER TO LOCATE END WALL COLUMNS TO NOT CONFLICT WITH WALL OPENINGS. 2. ALTERNATE: ADD INTERIOR COLUMNS AT GRIDS 2 AND 3 - SEE ARCHITECTURAL FLOOR PLAN FOR LOCATIONS. 3. PRE-ENGINEERED BUILDING MANUFACTURER IS RESPONSIBLE FOR STRUCTURAL DESIGN BY A STATE OF IOWA REGISTERED STRUCTURAL ENGINEER. 4. ACCEPTABLE PORTAL FRAME AND X-BRACING LOCATION SHOWN. IF MORE ARE REQUIRE, CONSULT WITH ARCHITECT PRIOR TO SUBMITTING BID. 5. OUTSET GIRTS AT END WALLS (NORTH AND SOUTH) 6. INSET GIRTS AT SIDE WALLS (EAST AND WEST) 7. PROVIDE POSTS AT FRAMES AND GIRTS TO FORM PARAPETS. 8. PROVIDE BEAMS SECURED TO FRAMES ON GRIDS 2, 3, & 4 TO SUPPORT SUSPENDED PREP BOOTHS BELOW - SEE FLOOR PLAN. BOTTOM OF BEAMS TO BE ABOVE BOTTOMS OF ADJACENT FRAMES. 9. PROVIDE BEAM OVER STOREFRONTS TO SUPPORT CONVENTIONAL STRUCTURE ABOVE - SEE WALL SECTIONS. 10. PROVIDE STRUCTURAL STANDING SEAM ROOF W/ GALVALUME FINISH. 11. INSULATE METAL WALL PANELS BY OTHERS. 12. PROVIDE ROOF EDGE FLASHING, GUTTERS AND DOWNSPOUTS 13. PROVIDE ADDITIONAL ROOF STRUCTURE TO SUPPOR BRICK ON STUD WALLS ABOVE ROOF - SEE ROOF PLAN. 14. ROOF LIVE LOAD: 20 PSF LIVE LOAD, + ROOF SNOW LOAD DETERMINED BY METAL BUILDING ENGINEER (MINIMUM 24 PSF REQUIRED BY CITY). 15. COLLATERAL LOAD: 5 TO 7 PSF FOR LIGHTS, MECHANICAL, ELECTRICAL, SPRINKLER , ETC. 16. SPECIAL DEFLECTIONS: A: BEAMS OVER STOREFRONTS: 1/720. B: STRUCTURE SUPPORTING BRICK ON STUD WALLS ABOVE ROOF: 1/360 VERTICAL. C: GIRTS SUPPORTING EIFS AND BRICK: 1/360 HORIZONTAL. DESCRIPTIONISSUE #ISSUE DATE NBI #: 17-1-734DBS #: 17-3-152 DESCRIPTIONISSUE #ISSUE DATE 1 GENERAL CONTRACTOR - ARCHITECT 1435 ohio street/p.o. box 1315 / des moines, ia 50305-1315 phone: (515) 243-0156 / fax: (515) 243-0165 NEUMANN BROTHERS, INC. - DESIGNBUILD SOLUTIONS 1 A 02/24/18 BUDGET SETSTIVERS FORD MERCURY 2 3 4 5 6 7 8 B C D E REVIEW SET 2 03/05/18 BUDGET SET 3 04/18/18 REVIEW SET A110 FLOOR PLAN AUTO BODY BUILDING WAUKEE, IOWA 1/8" = 1'-0"A110 F1 FLOOR PLANN A200 A2 A200 D2 A200 E2 65432 7 81 A1 A300 E1 A401 E5 A401 E1 A400 E4 A400 E7 A400 E6 A400 E4 A401 A B E1 A300 E2 A400 E7 A401 E3 A401 21'-8 1/2"VERIFY29'-2"SCREEN WALL SCREEN WALL STRUCTURAL STANDING LOCK SEAM BY METAL BLDG. MFR W/ GALVALUME FINISH OVER SIMPLE SAVE EINSULATION SYSTEM CONSISTING OF R-11 FIBERGLASS INSULATION DRAPED OVER PURLINS WITH R-19 FIBERGLASS INSTALLED PARALLEL TO PURLINS W/ SIMPLE SAVER FP FABRIC LINER VAPOR BARRIER/FALL PROTECTION. A600 D5 A600C5 3"3"3"3 1/8"3" A201 B1 A201 D1 A201 E1 3"3"27'-0" A.F.F. AT EAST WALL, 25'-4" A.F.F. AT WEST WALL ROOF CLAMP EQUAL TO RCT GALVANIZED STEEL FRAMING: L 2 1/2X 2 1/2 X 3/16" POSTS, BRACE AND SUPPORT RAIL AT 3'-0" O.C. METAL WALL PANEL : HORIZONTAL RIBS IN LINE WITH THAT OF RIB PANEL WALLS VARIESPERFORATED RIB PANEL EQUAL TO CENTRIA ECOSCREEN 22'-10" A.F.F. AT EAST WALL 21'-4" A.F.F. AT WEST WALL DESCRIPTIONISSUE #ISSUE DATE NBI #: 17-1-734DBS #: 17-3-152 DESCRIPTIONISSUE #ISSUE DATE 1 GENERAL CONTRACTOR - ARCHITECT 1435 ohio street/p.o. box 1315 / des moines, ia 50305-1315 phone: (515) 243-0156 / fax: (515) 243-0165 NEUMANN BROTHERS, INC. - DESIGNBUILD SOLUTIONS 1 A 02/24/18 BUDGET SETSTIVERS FORD MERCURY 2 3 4 5 6 7 8 B C D E REVIEW SET 2 03/05/18 BUDGET SET 3 04/18/18 REVIEW SET A120 ROOF PLAN AUTO BODY BUILDING WAUKEE, IOWA 1/8" = 1'-0"A120 E1 ROOF PLAN 1" = 1'-0"A120 C7 SCREEN WALL SECTION N