HomeMy WebLinkAbout2018-12-17-J11 Tri-Point Holdings - Site Plan AGENDA ITEM: J11
CITY OF WAUKEE, IOWA
CITY COUNCIL MEETING COMMUNICATION
MEETING DATE: December 17, 2018
AGENDA ITEM: Consideration of approval of a resolution approving a site plan for Tri-Point
Holdings (651 NE Venture Drive)
FORMAT: Resolution
SYNOPSIS INCLUDING PRO & CON: Tri-Point Holdings requests approval of a site plan to allow
for the construction of a single-story, office/retail building for a Remax office
and two future tenants. The site plan identifies the proposed building as being
9,861 square feet in area. The subject property is located north of Hickman
Road and east of NE Westgate Drive.
The applicant has provided elevations for the proposed building on the site,
which meets the intent of the architectural guidelines within the Site
Development and Building Standards Ordinance.
FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS:
COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning
Commission reviewed this project at the November 13, 2018 Commission Meeting and
recommended approval subject to remaining staff comments:
Approval of a Site Plan for Tri-Point Holdings (651 NE Venture Drive)
City Planner, Melissa DeBoer, introduced the request for approval of a Site Plan for an Office/Retail
building as submitted by the applicant, Tri- Point Holdings. The subject property is located north of
Hickman Road and west of NE Alice’s Road, containing approximately 1.49 acres. The project
involves the construction of a single-story office/ retail building for a Re-max office and two future
tenants that are unknown at this time. The building is approximately 9861 square feet in area, with
4,850 square feet dedicated to the Re-max tenant.
Mrs. DeBoer advised that access is provided off of NE Venture Drive and off of the Private Road
along the east side of the site. All utilities will be provided to this site and storm water detention will
be accommodated in the existing private detention basins located to the north of this site. All parking,
landscape, and open space requirements are met with this proposal.
Staff recommends approval of the site plan for Tri-Point Holdings subject to remaining staff
comments.
Commissioner Hoifeldt verified that the comment from staff to break up the north façade was
met. Staff advised it was accomplished and is shown in the renderings provided.
Commissioner Tietz and Koshy questioned if there was a reason for the extra parking spaces.
Mrs. DeBoer advised there was no particular reason, but it did allow for more flexibility in the
other two tenant spaces.
Commissioner Hoifeldt made a motion to approve a site plan for Tri-Point Holdings- Retail Building
(651 NE Venture Drive) subject to any remaining staff comments. Commissioner Koshy seconded the
motion. Ayes: Sandie, Tietz, Hoifeldt, and Koshy. Nays: None. Motion Carries.
STAFF REVIEW AND COMMENT: Staff recommends approval subject to remaining staff
comments.
RECOMMENDATION: Approve the resolution.
ATTACHMENTS: I. Proposed Resolution
II. Staff Report
III. Site Plan & Elevations
PREPARED BY: Melissa DeBoer, Planner II
REVIEWED BY:
THE CITY OF WAUKEE, IOWA
RESOLUTION 18-
APPROVING THE SITE PLAN FOR TRI-POINT HOLDINGS (651 NE VENTURE
DRIVE)
IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA
WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal
Organization; AND,
WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of
the Site Plan for Tri-Point Holdings, subject to remaining staff comments on November 13,
2018; AND,
WHEREAS, the Site Plan for Tri-Point Holdings is in general conformance with §304 – Site
and Building Development Standards Ordinance of the Waukee Municipal Code; AND,
WHEREAS, the Site Plan for Tri-Point Holdings is in general conformance with §301.27(A) –
Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND,
NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on
this 17th day of December, 2018 that the Site Plan for Tri-Point Holdings is approved.
____________________________
William F. Peard, Mayor
Attest:
___________________________________
Rebecca D. Schuett, City Clerk
RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN
Anna Bergman
R. Charles Bottenberg
Courtney Clarke
Shelly Hughes
Larry R. Lyon
PLANNING AND ZONING COMMISSION STAFF REPORT
PROJECT: Tri-Point Holdings – Site Plan PREPARED BY: Melissa DeBoer, AICP – Planner II
REPORT DATE: November 9, 2018
MEETING DATE: November 13, 2018
GENERAL INFORMATION
Owner/Developer: Tri-Point Holdings
Project Manager: Monte Appelgate, LA – Snyder & Associates, Inc.
Request: The applicant is requesting approval of a site plan
for an office/retail building.
Location and Size: Property is located north of Hickman Road and
west of NE Alice’s Road, containing approximately
1.49 acres.
Property Address: 651 NE Venture Drive
AREA MAP
ABOVE: Aerial of subject property (outlined in RED) in relation to the surrounding area.
November 8, 2018
2 of 3
LAND USES AND ZONING
Location Existing Land Use Comprehensive Plan Current Zoning
Property in
Question
Undeveloped Community Village C-1B (Large Scale Commercial
District)
North Vacant - Undeveloped Community Village R-3 / PD-1 (Multi-Family
Residential District with a
planned development overlay)
South Veridian Credit Union
(currently under
construction)
Community Village C-1B (Large Scale Commercial
District)
East Vacant – Undeveloped and
Hy-Vee
Community Village C-1B (Large Scale Commercial
District)
West Vacant – Undeveloped Community Village C-1B (Large Scale Commercial
District)
PROJECT DESCRIPTION
The project involves the construction of a single-story, office/retail building for a Remax office and two future
tenants (tenants are unknown at this time). The building is proposed to be approximately 9,861 square feet in
area. 4,850 square feet will be the Remax office space and the remaining 5,011 square feet will be vacant
general commercial space for future tenants. A trash enclosure is proposed at the northwest corner of the
site, located behind the building.
ACCESS AND PARKING
Two accesses are provided to this site. One access is provided off of NE Venture Drive and one off of the
private road along the east side of the site.
A total of 36 parking spaces are required for this facility, this includes 3 spaces per 1,000 square feet of
building area for office and 4 spaces per 1,000 square feet of building area for general commercial. The total
amount of parking proposed is 46 spaces, including four accessible spaces. The site plan also shows a
possibility of expanding the parking lot on the north side of the site and adding 16 spaces in the future if
necessary. The proposed site plan meets the parking requirements of the ordinance.
SIDEWALKS/TRAILS
An eight foot wide sidewalk will be provided along the east side of this site to provide a connection to the
existing sidewalk to the south, along the Veridian Credit Union site. Internal sidewalks are proposed around
the building.
UTILITIES
All utilities will be provided to this site. The site plan identifies the water connection coming from the water
main located to the east of the site. The sanitary connection will be provided through an extension of the
existing 8-inch main that runs along the Veridian site to the south. Storm water detention will be
accommodated in the existing private detention basins located to the north of this site. The water in these
basins eventually drain into the regional basin located just north of NE Horizon Drive and west of NE Alice’s
Road.
November 8, 2018
3 of 3
LANDSCAPING & OPEN SPACE
A minimum of 20% of the project area is required to be open space. The total amount of open space
proposed is 40%. The applicant has provided the required amount of plantings per the landscaping ordinance.
ELEVATIONS
The proposed building is a single story building. The elevations of the building are proposed to be constructed
of stone, cement board, architectural metal panels, and burnished block. Metal canopies are shown over the
windows on both the south and east elevations of the building.
MISCELLANEOUS:
The applicant has submitted a photometric plan and associated light fixture cut sheets. The lighting plan meets the
lighting requirements of the Site Plan Ordinance.
STAFF RECOMMENDATION
Staff recommends approval of the site plan for Tri-Point Holdings subject to remaining staff comments.
S H E E T T I T L E .
S H E E T N O .
C
ISSUE DATE :
PROJECT
NO :
D R A W I N G I S S U E I N F O R M A T I O N .
M A N A G E M E N T I N F O R M A T I O N .
M A R K D E S C R I P TI O ND A T E
P R O J E C T N A M E .
DRAWN BY :
PRINCIPAL
IN CHARGE :ARCHITECT :
PROJECT
CHECKED BY :
2 3 4 5
A
B
C
D D
C
B
A
2 3 4 5
ISSUE FOR :
THESE DOCUMENTS HAVE BEEN PREPARED SPECIFICALLY
FOR THE PROJECT REFERENCED ABOVE. THEY ARE NOT TO
BE USED FOR OTHER PROJECTS OR IN LOCATIONS OTHER
THAN SPECIFIED WITHOUT THE WRITTEN APPROVAL AND
PARTICIPATION OF ETHOS DESIGN GROUP, INC.
Office: 515.984.3077 Website: www.ethos.archi
119 Second Street, PO Box 169 Polk City, IA 50226
2018 ETHOS DESIGN GROUP, INC.
TRI-POINT HOLDINGS
OWNER .
WAUKEE, IA 50007
TRI-POINT HOLDINGS -
RETAIL BUILDING
11.06.2018
TLS
ARCHITECT AND INTERIOR DESIGNER
119 SECOND STREET, PO BOX 169
POLK CITY, IA 50226
Tel. 515.984.3077
ETHOS DESIGN GROUP, INC.
MAA
MECHANICAL AND ELECTRICAL ENGINEER
STRUCTURAL ENGINEER
604 LOCUST STREET, SUITE 202
DES MOINES, IOWA 50309
Tel. 515.279.3900
SAUL ENGINEERING, INC.
413 TYLER STREET
POLK CITY, IA 50226
Tel. 515.473.0030
BUTLER ENGINEERING, INC.
CIVIL E N G I N E E R
2727 SW SNYDER BLVD.
ANKENY, IA 50023
Tel. 515.964.2020
SNYDER & ASSOCIATES, INC.
1
1
5TH CITY SITE PLAN SUBMITTAL
S&A: 118.0753
MAA
651 NE VENTURE DRIVE
INDEX OF SHEETS
VICINITY MAP
NOT TO SCALE
PROJECT LOCATION
HICKMAN RD/US-6NE WESTGATE DRNE ALICE'S RDC100
TITLE SHEET
TRI-POINT HOLDINGS - RETAIL BUILDING
PLANTING PLAN
EROSION AND SEDIMENT CONTROL PLAN
GRADING PLAN
UTILITY PLAN
DIMENSION PLAN
PROJECT INFORMATION
TITLE SHEET
OWNER/DEVELOPER
EMAIL: SHANETORRES@REMAX.NET
PHONE: (515) 984-0222
CONTACT: SHANE TORRES
POLK CITY, IA 50226
905 W BRIDGE ROAD, SUITE 2
TRI-POINT HOLDINGS
ENGINEER
Date
IOWALICENSEDPROFESSIO
N
A
LEN
GI
NEERLicense Number
Pages or sheets covered by this seal:
My License Renewal Date is December 31, 2019
18954
18954
CANNON
ERIC D.Eric D. Cannon, P.E.
under the laws of the State of Iowa.
licensed Professional Engineer
supervision and that I am a duly
by me or under my direct personal
engineering document was prepared
I hereby certify that this
SHEETS 1-6
PHONE: (515) 964-2020
CONTACT: ERIC CANNON P.E.
ANKENY, IA 50023
2727 SW SNYDER BLVD
SNYDER & ASSOCIATES, INC
C600.
C500.
C400.
C300.
C200.
C101.
C100.
NE VENTURE DR
STATE OF
IO
WA
PROFESSIO
N
ALLANDSCAPE AR CHITECTDate
License Number
Pages or sheets covered by this seal:
342
NO.
ARCHITECT
LANDSCAPE
under the laws of the State of Iowa.
Professional Landscape Architect
charge. I am a duly licensed
direct supervision and responsible
below was prepared by me or under my
this technical submission described
I hereby certify that the portion of
June 30, 2020
License Expires:
342
APPELGATE
MONTE A.
Monte A. Appelgate, ASLA
CITY OF WAUKEE, DALLAS COUNTY, IOWA
651 NE VENTURE DRIVE
SITE PLANS FOR
S H E E T T I T L E .
S H E E T N O .
C
ISSUE DATE :
PROJECT
NO :
D R A W I N G I S S U E I N F O R M A T I O N .
M A N A G E M E N T I N F O R M A T I O N .
M A R K D E S C R I P TI O ND A T E
P R O J E C T N A M E .
DRAWN BY :
PRINCIPAL
IN CHARGE :ARCHITECT :
PROJECT
CHECKED BY :
2 3 4 5
A
B
C
D D
C
B
A
2 3 4 5
ISSUE FOR :
THESE DOCUMENTS HAVE BEEN PREPARED SPECIFICALLY
FOR THE PROJECT REFERENCED ABOVE. THEY ARE NOT TO
BE USED FOR OTHER PROJECTS OR IN LOCATIONS OTHER
THAN SPECIFIED WITHOUT THE WRITTEN APPROVAL AND
PARTICIPATION OF ETHOS DESIGN GROUP, INC.
Office: 515.984.3077 Website: www.ethos.archi
119 Second Street, PO Box 169 Polk City, IA 50226
2018 ETHOS DESIGN GROUP, INC.
TRI-POINT HOLDINGS
OWNER .
WAUKEE, IA 50007
TRI-POINT HOLDINGS -
RETAIL BUILDING
11.06.2018
TLS
ARCHITECT AND INTERIOR DESIGNER
119 SECOND STREET, PO BOX 169
POLK CITY, IA 50226
Tel. 515.984.3077
ETHOS DESIGN GROUP, INC.
MAA
MECHANICAL AND ELECTRICAL ENGINEER
STRUCTURAL ENGINEER
604 LOCUST STREET, SUITE 202
DES MOINES, IOWA 50309
Tel. 515.279.3900
SAUL ENGINEERING, INC.
413 TYLER STREET
POLK CITY, IA 50226
Tel. 515.473.0030
BUTLER ENGINEERING, INC.
CIVIL E N G I N E E R
2727 SW SNYDER BLVD.
ANKENY, IA 50023
Tel. 515.964.2020
SNYDER & ASSOCIATES, INC.
1
1
5TH CITY SITE PLAN SUBMITTAL
S&A: 118.0753
MAA
651 NE VENTURE DRIVE
PLAT DESCRIPTION
ZONING/BULK REGULATIONS
93
93.0
93
C
OC
FO
E
OE
4" G
4" HPG
8" W
8" S
12" ST12" ST
G
G
AST
UST
Features Existing Proposed
G
EB
W
LEGEND
8" W(*)
8" S(*)
4" G(*)
4" HPG(*)
C(*)
OC(*)
FO(*)
E(*)
OE(*)
DUCT(*)
93.0
1
Soil Boring
Mailbox
Satellite Dish
Sign
Above Ground Storage Tank
Underground Storage Tank
Fence Post or Guard Post
Gas Apparatus
Gas Manhole
Gas Valve
Fiber Optic Handhole
Fiber Optic Manhole
Communication Handhole
Communication Manhole
Communication Pedestal
Traffic Sign
Electric Transformer
Electric Box
Yard Light
Street Light
Utility Pole with Transformer
Utility Pole with Light
Guy Anchor
Utility Pole
Well
Water Service Valve
Water Main Valve
Fire Hydrant on Building
Fire Hydrant
Double Storm Sewer Intake
Single Storm Sewer Intake
Storm Manhole
Storm Sewer with Size
Sanitary Manhole
(*) Denotes the survey quality service level for utilities
Test Hole Location for SUE w/ID
Duct Bank
Sanitary Sewer with Size
Water Main with Size
High Pressure Gas Main with Size
Gas Main with Size
Overhead Electric
Underground Electric
Fiber Optic
Overhead Communication
Communication
Coniferous Tree or Shrub
Deciduous Tree or Shrub
Tree Stump
Tree Line
Fence (Silt)
Fence (Wood)
Fence (Chain Link)
Fence (Barbed, Field, Hog)
Contour Elevation
Spot Elevation
GENERAL NOTES POLLUTION PREVENTION NOTES
UTILITY CONTACT INFORMATION
UTILITY QUALITY SERVICE LEVELS
UTILITY WARNING
SYSTEM, TICKET NUMBER 551800814.
RECEIVED FROM THE IOWA ONE CALL DESIGN REQUEST
UTILITY CONTACT FOR MAPPING INFORMATION SHOWN AS
BUILDING DESCRIPTION
f. COOPERATE TO PROVIDE INFORMATION UNDER THE RESPONSIBILITY OF OTHERS.
e. UPDATE AND MAINTAIN THE ONSITE SWPPP.
d. WEEKLY INSPECTIONS AND CORRESPONDING RECORDS.
MEASURES.
c. INSTALL, MAINTAIN, AND REMOVE EROSION CONTROL AND POLLUTION PREVENTION
b. COMPLY WITH THE REQUIREMENTS OF THE GENERAL PERMIT No.2 AND THE SWPPP.
CERTIFICATION OF SUBCONTRACTOR CO-PERMITEES.
a. SIGN NPDES CERTIFICATION STATEMENT AS CO-PERMITEE AND COORDINATING
3. RESPONSIBILITIES OF THE CONTRACTOR:
d. SUBMIT THE NOTICE OF DISCONTINUATION.
COVERAGE.
c. FILE THE NOTICE OF INTENT WITH APPLICATION FEE FOR NPDES GENERAL PERMIT No. 2
b. PUBLISH THE PUBLIC NOTICE OF STORM WATER DISCHARGE.
a. CREATE THE INITIAL SWPPP.
2. RESPONSIBILITIES OF THE ENGINEER:
b. ALL REQUIREMENTS NOT ASSIGNED TO OTHERS.
a. SIGN NPDES CERTIFICATION STATEMENT AS PERMITEE.
1. RESPONSIBILITIES OF THE OWNER:
D. PROJECT SPECIFIC REQUIREMENTS FOR POLLUTION PREVENTION AND EROSION PROTECTION
FILING OF THE "NOTICE OF DISCONTINUATION".
k. REMOVE ALL TEMPORARY EROSION CONTROL MEASURES AND SITE WASTE PRIOR TO
MUST BE CONTAINED ONSITE.
SEDIMENT BASIN OR OTHER CONTROL DEVICE WHERE POSSIBLE. CONCRETE WASHOUT
STAGING AREAS WITH DIVERSION BERMS AND/OR SILT BARRIERS AND DIRECT TO A
MATERIALS STORAGE, AND CONCRETE WASHOUT FACILITY. CONTROL RUNOFF FROM
JOB TRAILERS, FUELING / VEHICLE MAINTENANCE AREA, TEMPORARY SANITARY FACILITIES,
SWPPP. UNLESS NOTED OTHERWISE, STAGING AREAS SHOULD CONTAIN THE FOLLOWING:
j. COORDINATE LOCATIONS OF STAGING AREAS WITH THE OWNER AND RECORD IN THE
EXCEEDING 14 CALENDAR DAYS.
CEASED ON ANY PORTION OF THE SITE AND WHICH WILL NOT RESUME FOR A PERIOD
IMMEDIATELY AFTER CONSTRUCTION ACTIVITY IS FINALLY COMPLETED OR TEMPORARILY
COMPLETION OR DELAY OF GRADING OPERATIONS. INITIATE STABILIZATION MEASURES
PERMANENT SEED MIX, SOD, OR PAVEMENT IMMEDIATELY AS SOON AS POSSIBLE UPON
i. STABILIZE UNDEVELOPED, DISTURBED AREAS WITH MULCH, TEMPORARY SEED MIX,
ARE LOCATED.
ALL DISTURBED AREAS, EXCEPT WHERE PAVEMENT, BUILDINGS OR OTHER IMPROVEMENTS
h. RESPREAD A MINIMUM OF 8 INCHES OF TOPSOIL (INCLUDING TOPSOIL FOUND IN SOD) ON
ARE INSTALLED.
CONTROL. PROVIDE INLET AND OUTLET CONTROL MEASURES AS SOON AS STORM SEWERS
AND AS CONSTRUCTION OPERATIONS PROGRESS TO ENSURE CONTINUOUS RUNOFF
MATS, MULCH, DITCH CHECKS OR RIPRAP AS SOON AS AREAS REACH THEIR FINAL GRADES
g. INSTALL NECESSARY CONTROL MEASURES SUCH AS SILT BARRIERS, EROSION CONTROL
DEBRIS IMMEDIATELY AND TAKE REMEDIAL ACTIONS FOR FUTURE PREVENTION.
DRAINAGEWAYS, OR UNDERGROUND SEWERS. REMOVE ANY ACCUMULATION OF EARTH OR
ADJOINING PUBLIC OR PRIVATE PROPERTIES, INCLUDING STREETS, DRIVEWAYS, SIDEWALKS,
f. PREVENT ACCUMULATION OF EARTH AND DEBRIS FROM CONSTRUCTION ACTIVITIES ON
SWPPP AND IMPLEMENT ANY RECOMMENDED MEASURES WITHIN 7 DAYS.
SUBMITTED WEEKLY TO THE OWNER OR ENGINEER DURING CONSTRUCTION. REVISE THE
OF THESE INSPECTIONS AND ANY RESULTING ACTIONS IN THE SWPPP WITH A COPY
ASSIGNED BY THE CONTRACTOR) EVERY SEVEN CALENDAR DAYS. RECORD THE FINDINGS
e. INSPECT THE PROJECT AREA AND CONTROL DEVICES (BY QUALIFIED PERSONNEL
THE MEASURES HAVE LOST 50% OF THEIR ORIGINAL CAPACITY.
THROUGHOUT THE PERMIT PERIOD. CLEAN OR REPLACE SILT CONTROL DEVICES WHEN
ORDER, INCLUDING CLEANING, REPAIRING, REPLACEMENT, AND SEDIMENT REMOVAL
d. MAINTAIN ALL TEMPORARY AND PERMANENT EROSION CONTROL MEASURES IN WORKING
TIME.
TO A MINIMUM THE TOTAL AREA DISTURBED BY CONSTRUCTION OPERATIONS AT ANY
c. PRESERVE EXISTING VEGETATION IN AREAS NOT NEEDED FOR CONSTRUCTION AND LIMIT
DISTURBING ACTIVITIES PRIOR TO SITE CLEARING AND GRADING OPERATIONS.
DITCH CHECKS, DIVERSION BERMS, OR SEDIMENTATION BASINS DOWNSTREAM OF SOIL
b. INSTALL PERIMETER AND FINAL SEDIMENT CONTROL MEASURES SUCH AS SILT BARRIERS,
AND MAXIMIZE STORM WATER INFILTRATION, AND MINIMIZE SOIL COMPACTION.
WATERS, DIRECT STORM WATER TO VEGETATED AREAS TO INCREASE SEDIMENT REMOVAL
DISCHARGING FROM BASINS, PROVIDE AND MAINTAIN NATURAL BUFFERS AROUND SURFACE
a. UTILIZE OUTLET STRUCTURES THAT WITHDRAW WATER FROM THE SURFACE WHEN
UNLESS INFEASIBLE OR NOT APPLICABLE:
GENERAL PERMIT AND SWPPP, INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING BMP'S
4. THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL REQUIREMENTS OF THE
CONSTRUCTION PROGRESS AND CHANGES AT THE PROJECT SITE.
3. THE SWPPP AND SITE MAP SHOULD BE EXPEDITIOUSLY REVISED TO REFLECT
FROM THOSE SHOWN ON THE PLAN MAY BE REQUIRED.
RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY, NOTE AND IMPLEMENT. ADDITIONAL BMP'S
CONTROL MEASURES REQUIRED AS A RESULT OF CONSTRUCTION ACTIVITIES ARE THE
FOR COMPLIANCE WITH THE PROJECT'S NPDES PERMIT COVERAGE. ALL BMP'S AND EROSION
2. THE SWPPP ILLUSTRATES GENERAL MEASURES AND BEST MANAGEMENT PRACTICES (BMP)
MADE DURING CONSTRUCTION.
FOR ADDITIONAL REQUIREMENTS AND MODIFICATIONS TO THE POLLUTION PREVENTION PLAN
ADDITION TO THESE PLAN DRAWINGS. THE CONTRACTOR SHOULD REFER TO THE SWPPP
1. THE STORM WATER POLLUTION PREVENTION PLAN (SWPPP) IS A SEPARATE DOCUMENT IN
C. POLLUTION PREVENTION PLAN
ACCEPTANCE AND/OR SUBMITTAL OF THE NOTICE OF DISCONTINUATION.
RECORD COPY AND PROVIDE THE ORIGINAL DOCUMENTS TO THE OWNER UPON PROJECT
PERIOD OF THREE YEARS AFTER PROJECT COMPLETION. THE CONTRACTOR SHALL RETAIN A
ALL PLANS, INSPECTION REPORTS, AND OTHER DOCUMENTS MUST BE RETAINED FOR A
OF THE DISTURBED SITE AND REMOVAL OF ALL TEMPORARY EROSION CONTROL MEASURES.
3. A "NOTICE OF DISCONTINUATION" MUST BE FILED WITH THE IDNR UPON FINAL STABILIZATION
THE CLEAN WATER ACT AND THE CODE OF IOWA.
REQUEST. FAILURE TO COMPLY WITH THE NPDES PERMIT REQUIREMENTS IS A VIOLATION OF
AT ALL TIMES AND MUST BE PRESENTED TO ANY JURISDICTIONAL AGENCIES UPON
LETTER, CURRENT SWPPP, SITE INSPECTION LOG, AND OTHER ITEMS, SHALL BE KEPT ON SITE
LIMITED TO, THE NOTICE OF INTENT, PROOF OF PUBLICATIONS, DISCHARGE AUTHORIZATION
2. ALL DOCUMENTS RELATED TO THE STORM WATER DISCHARGE PERMIT, INCLUDING, BUT NOT
DOCUMENTS.
ALL REQUIREMENTS OF THE NPDES GENERAL PERMIT NO. 2 AS SPECIFIED IN THE CONTRACT
AND ALL SUBCONTRACTORS ARE RESPONSIBLE FOR COMPLIANCE WITH AND FULFILLMENT OF
REQUIRED BY THE ENVIRONMENTAL PROTECTION AGENCY (EPA). THE GENERAL CONTRACTOR
WATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITIES FROM THE IDNR, AS
1. THIS PROJECT REQUIRES COVERAGE UNDER THE NPDES GENERAL PERMIT NO. 2 FOR STORM
B. STORM WATER DISCHARGE PERMIT
ITEMS AND DEDUCT THE COST THEREOF FROM AMOUNTS DUE TO THE CONTRACTOR.
ADJOINING PUBLIC OR PRIVATE PROPERTY, THE OWNER MAY, BUT NEED NOT, REMOVE SUCH
STEPS TO PROMPTLY REMOVE EARTH SEDIMENTATION OR DEBRIS WHICH COMES ONTO
FEES INCURRED TO OWNER. FURTHER, IF THE CONTRACTOR FAILS TO TAKE NECESSARY
DAMAGES TO ADJOINING PUBLIC OR PRIVATE PROPERTY, INCLUDING REASONABLE ATTORNEY
HARMLESS FROM ANY AND ALL CLAIMS OF ANY TYPE WHATSOEVER RESULTING FROM
2. DAMAGE CLAIMS: THE CONTRACTOR WILL HOLD THE OWNER AND ARCHITECT / ENGINEER
PERFORMANCE.
OFF-SITE BORROW OR DEPOSIT AREAS DURING PERFORMANCE OR AS A RESULT OF
TO PROTECT AGAINST EROSION AND POLLUTION FROM THIS PROJECT SITE AND ALL
ACT AND ANY LOCAL ORDINANCES. THE CONTRACTOR SHALL TAKE ALL NECESSARY STEPS
IOWA DEPARTMENT OF NATURAL RESOURCES (IDNR) NPDES PERMIT, THE U.S. CLEAN WATER
POTENTIAL POLLUTION AND SOIL EROSION CONTROL REQUIREMENTS OF THE IOWA CODE, THE
CODE COMPLIANCE: THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL 1.
A. POLLUTION PREVENTION AND EROSION PROTECTION
BENCHMARKS
IARTN DERIVED - US SURVEY FEET
NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88 - GEOID12A)
CONTROL POINTS
NAD83(2011)(EPOCH 2010.00) IARTN DERIVED - US SURVEY FEET
IOWA REGIONAL COORDINATE SYSTEM ZONE 8 (AMES - DES MOINES)
BM2
BM1
C101
INFORMATION
PROJECT
CITY OF WAUKEE, DALLAS COUNTY, IOWA.
LOT 11 PRAIRIE CROSSING PLAT 7, AN OFFICIAL PLAT IN THE
3MAXIMUM NOUMBER OF STORIES:
50 FEETMAXIMUM HEIGHT REQUIREMENTS:
NONESIDE YARD:
50 FEETREAR YARD:
50 FEETFRONT YARD:
MINIMUM YARD REQUIREMENTS:
NONEMINIMUM LOT WIDTH:
NONEMINIMUM LOT AREA:
C1-B LARGE SCALE COMMERCIAL DISTRICT
PARKING REQUIREMENTS
GENERAL USE
OFFICE AND COMMERCIAL/RETAIL
PROJECT SCHEDULE
LOT INFORMATION
=29,538 SF (0.68 AC) (45.45%)OPEN SPACE
=35,490 SF (0.81 AC) (54.55%)IMPERVIOUS
=65,028 SF (1.49 AC)LOT AREA
troyer@waukee.org
515-978-7920
Tim Royer
CITY OF WAUKEE
pmay@mediacomcc.com
515-246-2252
Paul May
MEDIACOM COMMUNICATIONS CORP
MECDSMDesignLocates@midamerican.com
515-252-6632
Craig Ranfeld
MIDAMERICAN ELECTRIC ENERGY
Weston.grow@consolidated.com
507-387-1770
Weston Grow
CONSOLIDATED COMMUNICATIONS
Thomas.sturmer@centurylink.com
720-578-8090
Tom Sturmer
CENTURYLINK
G-GAS MAIN
ST-STORM SEWER
S-SANITARY SEWER
W-WATER
NO RESPONSE
CLEAR PER MAPS RECEIVED
NO RESPONSE
CLEAR PER MAPS RECEIVED
V-BBUILDING TYPE:
=5,011 SFFUTURE FLOOR SF
=4,850 SFOFFICE FLOOR SF
=28'-5"TOTAL BUILDING HEIGHT
EXTERIOR WALLS OF THE BUILDING AS MEASURED BY AN APPROVED ROUTE AROUND THE EXTERIOR OF THE BUILDING.
DD. APPROVED FIRE ACCESS ROAD SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 503.2 AND THIS SECTION AND SHALL EXTEND TO WITHIN 100 FEET OF ALL PORTIONS OF THE
CC. ALL SIGNAGE SHALL REQUIRE A SEPARATE PERMIT FROM THE CITY OF WAUKEE DEVELOPMENT SERVICES DEPARTMENT.
BB. CONTRACTOR SHALL COORDINATE ALL TIE-IN TO UTILITIES WITH THE CITY OF WAUKEE PUBLIC WORKS DEPARTMENT AND CITY OF WAUKEE PUBLIC WORKS SHALL WITNESS ALL TIE-INS.
AA. CONSTRUCTION OPERATIONS SHALL PROTECT STORM SEWERS AND DRAINAGE WAYS FROM ALLOWING CONCRETE SLURRY FROM CONCRETE OPERATIONS TO DISCHARGE OFFSITE.
TESTED TO CITY STANDARDS. THE CITY SHALL WITNESS ALL TESTING.
Z. ALL UTILITIES INCLUDING PRIVATE UTILITIES SHALL BE CONSTRUCTED TO THE CITY OF WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND ALL UTILITIES SHALL BE
DETENTION FACILITIES. THE CONTRACTOR SHALL PROVIDE INFORMATION TO THE DESIGN ENGINEER FOR INCLUSION ON THE RECORD AS-BUILT DRAWINGS.
Y. AS-BUILTS SHALL BE PROVIDED TO THE WAUKEE ENGINEERING DEPARTMENT INCLUDING ALL UTILITIES AND AS-BUILT GRADES FOR DRAINAGE SWALES, OVERFLOWS, ACCESSIBLE RAMPS AND
LOCATED AT THE BACK OF CURB AND ALL EXPANSION JOINTS SHALL BE SEALED.
X. PLACE 3/4" EXPANSION JOINT BETWEEN ALL PCC PAVEMENT/SIDEWALKS AND BUILDINGS. PLACE 1/2" EXPANSION JOINT BETWEEN SIDEWALKS AND PCC PAVEMENT. THE PCC RAMP JOINT
W. ALL CONNECTIONS TO EXISTING SANITARY MANHOLES SHALL BE CORE DRILL WITH A LINK SEAL.
REPORT AND VIDEO SHALL BE PROVIDED TO THE CITY OF WAUKEE. ALL SANITARY SEWER MANHOLES SHALL BE VACUUM TESTED.
V. ALL SANITARY SEWER AND STORM SEWER SHALL BE CLEANED AND TELEVISED PRIOR TO PAVING. THE CITY OF WAUKEE SHALL WITNESS ALL CLEANING AND TELEVISING. COPIES OF THE
SERVICES.
U. THE CONTRACTOR IS RESPONSIBLE FOR ANY CHANGES MADE DURING CONSTRUCTION THAT HAVE NOT BEEN GRANTED APPROVAL IN WRITING BY THE CITY OF WAUKEE DEVELOPMENT
T. ANY CHANGES PROPOSED TO THE DRAWINGS DURING CONSTRUCTION SHALL BE APPROVED IN WRITING BY THE CITY OF WAUKEE DEVELOPMENT SERVICES PRIOR TO CONSTRUCTION.
S. ALL STAKING SHALL BE DONE UNDER THE DIRECTION OF A LICENSED ENGINEER OR LAND SURVEYOR INCLUDING PEDESTRIAN FACILITIES.
R. A PRE-CONSTRUCTION MEETING WITH THE CITY OF WAUKEE WILL BE REQUIRED A MINIMUM OF ONE WEEK PRIOR TO CONSTRUCTION ACTIVITIES BEGINNING.
MAIN TO THE STORM SEWER IS AT LEAST TEN FEET.
FLEXIBLE O-RING GASKET RATED AT 13 PSI OR GREATER. O-RING GASKET JOINTS SHALL BE INSTALLED ON EACH SIDE OF THE CROSSING UNTIL THE NORMAL DISTANCE FROM THE WATER
Q. IF STORM SEWER CROSSES ABOVE WATER MAIN OR CROSSES LESS THAN 18" BELOW A WATER MAIN THEN STORM SEWER SHALL BE CONSTRUCTED OF REINFORCED CONCRETE WITH A
PRIOR TO CONSTRUCTION.
P. CONTRACTOR TO COORDINATE NATURAL GAS, ELECTRICAL, TELEPHONE AND ANY OTHER FRANCHISE UTILITY SERVICES WITH UTILITY SERVICE PROVIDER, CITY OF WAUKEE, AND THE OWNER
COSESCO PERMIT IS REQUIRED FOR THIS PROJECT.
ANY EXISTING EROSION CONTROL MEASURES ON SITE AT THE TIME OF CONSTRUCTION. GRADING AND SOIL EROSION CONTROL CODE REQUIREMENTS SHALL BE MET BY CONTRACTOR. A
O. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING EROSION AND SEDIMENT CONTROL MEASURES AS NECESSARY. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR MAINTAINING
N. THE ADJUSTMENT OF ANY EXISTING UTILITY APPURTENANCES TO FINAL GRADE IS CONSIDERED INCIDENTAL TO THE SITE WORK.
EACH WORK DAY AND PRIOR TO A RAIN EVENT.
M. THE CONTRACTOR IS RESPONSIBLE FOR CLEANING DIRT AND DEBRIS FROM NEIGHBORING STREETS, DRIVEWAYS, AND SIDEWALKS CAUSED BY CONSTRUCTION ACTIVITIES AT THE END OF
L. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS SHOWN ARE FINISHED GRADES AND/OR TOP OF PAVING SLAB (GUTTER), UNLESS OTHERWISE NOTED.
SECTION 2010.
K. CONTRACTOR TO STRIP AND STOCKPILE TOPSOIL FROM ALL AREAS TO BE CUT OR FILLED. RESPREAD TO MINIMUM 8" DEPTH TO FINISH GRADES TO CONFORM TO SUDAS SPECIFICATIONS
J. CONTRACTOR TO LOAD AND TRANSPORT ALL MATERIALS CONSIDERED TO BE UNDESIRABLE TO BE INCORPORATED INTO THE PROJECT TO AN APPROVED OFF-SITE WASTE SITE.
AND THAT ANY CHANGES COMPLETED WITHOUT APPROVAL ARE SUBJECT TO REMOVAL IN ORDER TO MEET THE CITY OF WAUKEE STANDARDS.
CONTRACTOR SHALL BE RESPONSIBLE FOR LAYOUT VERIFICATION OF ALL SITE IMPROVEMENTS PRIOR TO CONSTRUCTION. CONTACT CITY OF WAUKEE FOR APPROVAL OF ANY CHANGES
ANY SUCH CHANGES OR CONFLICTS BETWEEN THIS PLAN AND FIELD CONDITIONS ARE TO BE REPORTED TO THE ARCHITECT/ENGINEER PRIOR TO STARTING CONSTRUCTION. THE
I. DIMENSIONS, BUILDING LOCATION, UTILITIES AND GRADING OF THIS SITE ARE BASED ON AVAILABLE INFORMATION AT THE TIME OF DESIGN. DEVIATIONS MAY BE NECESSARY IN THE FIELD.
H. ALL FIELD TILES ENCOUNTERED DURING CONSTRUCTION SHALL BE RECONNECTED OR REPAIRED AND NOTED ACCORDINGLY ON THE AS-BUILT DOCUMENTS.
G. IN THE EVENT OF A DISCREPANCY BETWEEN THE QUANTITY ESTIMATES AND THE DETAILED PLANS, THE DETAILED PLANS SHALL GOVERN.
F. CONSTRUCT MANHOLES AND APPURTENANCES AS WORK PROGRESSES. BACKFILL WITH SUITABLE MATERIAL AND COMPACT TO 95% MAXIMUM DENSITY.
LEAST 48 HOURS PRIOR TO ANY PLANNED WEEKEND OR HOLIDAY WORK.
E. NOTIFY OWNER, ENGINEER, CITY OF WAUKEE AT LEAST 48 HOURS PRIOR TO BEGINNING WORK. CONTRACTOR SHALL ALSO NOTIFY THE CITY OF WAUKEE ENGINEERING DEPARTMENT AT
CONTRACTOR SHALL NOTIFY THE CITY OF WAUKEE AT LEAST ONE WEEK PRIOR TO ANY ANTICIPATED LANE CLOSURE.
ACTIVITIES OBSTRUCT PORTIONS OF THE ROADWAY, FLAGGERS SHALL BE PROVIDED. FLAGGERS SHALL CONFORM TO THE MUTCD IN APPEARANCE, EQUIPMENT AND ACTIONS. THE
D. ALL TRAFFIC CONTROL SHALL BE PROVIDED IN ACCORDANCE WITH REQUIREMENTS SET FORTH IN THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). WHEN CONSTRUCTION
C. LENGTH OF UTILITIES SHOWN ON PLANS ARE DIMENSIONED FROM CENTERLINE OF STRUCTURE TO CENTERLINE OF STRUCTURE.
AND SPECIFICATIONS AND THE SOILS REPORTS PREPARED BY OTHERS.
B. CONSTRUCTION OF ALL STREET AND UTILITY IMPROVEMENTS SHALL CONFORM TO THE WAUKEE STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS, 2018 STATEWIDE URBAN DESIGN
ANY DAMAGES TO UTILITY ITEMS NOT SHOWN FOR REMOVAL OR MODIFICATION SHALL BE REPAIRED TO THE UTILITY OWNER'S SPECIFICATIONS AT THE CONTRACTOR'S EXPENSE.
RESPONSIBLE FOR DETERMINING EXISTENCE, EXACT LOCATION, AND DEPTH OF ALL UTILITIES. PROTECT ALL UTILITY LINES AND STRUCTURES NOT SHOWN FOR REMOVAL OR MODIFICATION.
A. NOTIFY UTILITY PROVIDERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES AND COORDINATE WITH UTILITY PROVIDERS AS NECESSARY DURING CONSTRUCTION. CONTRACTOR IS
CHARACTERISTICS.
SUBSURFACE UTILITIES, AS WELL AS THE TYPE, SIZE, CONDITION, MATERIAL, AND OTHER
OBTAINED BY ACTUAL EXPOSURE OR VERIFICATION OF PREVIOUSLY EXPOSED
IS HORIZONTAL AND VERTICAL POSITION OF UNDERGROUND UTILITIES QUALITY LEVEL (A)
APPROXIMATE HORIZONTAL POSITION OF SUBSURFACE UTILITIES.
APPROPRIATE SURFACE GEOPHYSICAL METHODS TO DETERMINE THE EXISTENCE AND
INFORMATION IS OBTAINED THROUGH THE APPLICATION OF QUALITY LEVEL (B)
THIS INFORMATION WITH QUALITY D INFORMATION.
ABOVE-GROUND UTILITY FEATURES AND USING PROFESSIONAL JUDGMENT IN CORRELATING
INFORMATION IS OBTAINED BY SURVEYING AND PLOTTING VISIBLE QUALITY LEVEL (C)
RECOLLECTIONS.
INFORMATION IS DERIVED FROM EXISTING UTILITY RECORDS OR ORAL QUALITY LEVEL (D)
STANDARD.
AND WHEN APPLICABLE, SIZE. THE QUALITY LEVELS ARE BASED ON THE CI / ASCE 38-02
QUALITY LEVELS OF UTILITIES ARE SHOWN IN THE PARENTHESES WITH THE UTILITY TYPE
NOTED AS QUALITY LEVEL A.
OR SUBSURFACE FEATURES SHOWN ARE IN THE EXACT LOCATION INDICATED EXCEPT WHERE
SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UTILITIES
SUBSURFACE FEATURES SHOWN COMPRISE ALL SUCH ITEMS IN THE AREA, EITHER IN
RECORDS OBTAINED. THE SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES OR
THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR
OF SITE.
BURY BOLT ON HYDRANT, }10' SOUTH OF BACK OF CURB, SOUTHWEST CORNER
ELEV=1033.41
SOUTHEAST CORNER OF SITE.
BURY BOLT ON HYDRANT, SOUTHEAST QUADRANT OF INTERSECTION,
ELEV=1035.33
CORNER OF SITE.
1/2" REBAR WITH RED PLASTIC CAP, }300' NORTH OF ROAD, NORTHEAST
N=7498051.96 E=18461133.36 Z=1032.21
CORNER OF SITE.
1/2" REBAR WITH RED PLASTIC CAP, }300' NORTH OF ROAD, NORTHEAST
N=7498045.89 E=18461454.34 Z=1034.16
INTERSECTION, SOUTHEAST CORNER OF SITE.
CUT "X" BACK OF CURB AT END OF RADIUS, SOUTHEAST QUADRANT
N=7497727.29 E=18461487.27 Z=1304.09
CORNER OF SITE.
CUT "X" WEST SIDE BACK OF CURB INTAKE, SOUTH SIDE OF ROAD, SOUTHWEST
N=7497729.70 E=18461158.87 Z=1032.78
CONTROL POINTS
CP4
CP3
CP2
CP1
CP4
CP3
CP2
CP1
NAD83(2011)(EPOCH 2010.00) IARTN DERIVED - US SURVEY FEET
IOWA STATE PLANE SOUTH COORDINATE SYSTEM
CONTROL POINTS
CORNER OF SITE.
1/2" REBAR WITH RED PLASTIC CAP, }300' NORTH OF ROAD, NORTHEAST
N=589282 E=1542308 Z=1032.21
CORNER OF SITE.
1/2" REBAR WITH RED PLASTIC CAP, }300' NORTH OF ROAD, NORTHEAST
N=589275.2 E=1542629 Z=1034.16
INTERSECTION, SOUTHEAST CORNER OF SITE.
CUT "X" BACK OF CURB AT END OF RADIUS, SOUTHEAST QUADRANT
N=588956.5 E=1542661 Z=1304.09
CORNER OF SITE.
CUT "X" WEST SIDE BACK OF CURB INTAKE, SOUTH SIDE OF ROAD, SOUTHWEST
N=588959.7 E=1542333 Z=1032.78
=TBDGENERAL COMMERCIAL/RETAIL
=15OFFICE (REMAX) ESTIMATED EMPLOYEES
& 16 FUTURE)
=62 SPACES (INCLUDING 4 ACCESSIBLE SPACES PROVIDED
=36 SPACESSPACES REQUIRED
=21 SPACES=5,011 / 1,000 x 4GENERAL COMMERCIAL
=15 SPACES=4,850 / 1,000 x3OFFICE
=4 SPACES PER 1,000 GFAGENERAL COMMERCIAL:
=3 SPACES PER 1,000 GFAOFFICE:
FALL 2019COMPLETE CONSTRUCTION
SPRING 2019START CONSTRUCTION
5" PCC PAVEMENT
6" PCC PAVEMENT
7" PCC PAVEMENT
4" PCC SIDEWALK
S H E E T T I T L E .
S H E E T N O .
C
ISSUE DATE :
PROJECT
NO :
D R A W I N G I S S U E I N F O R M A T I O N .
M A N A G E M E N T I N F O R M A T I O N .
M A R K D E S C R I P TI O ND A T E
P R O J E C T N A M E .
DRAWN BY :
PRINCIPAL
IN CHARGE :ARCHITECT :
PROJECT
CHECKED BY :
2 3 4 5
A
B
C
D D
C
B
A
2 3 4 5
ISSUE FOR :
THESE DOCUMENTS HAVE BEEN PREPARED SPECIFICALLY
FOR THE PROJECT REFERENCED ABOVE. THEY ARE NOT TO
BE USED FOR OTHER PROJECTS OR IN LOCATIONS OTHER
THAN SPECIFIED WITHOUT THE WRITTEN APPROVAL AND
PARTICIPATION OF ETHOS DESIGN GROUP, INC.
Office: 515.984.3077 Website: www.ethos.archi
119 Second Street, PO Box 169 Polk City, IA 50226
2018 ETHOS DESIGN GROUP, INC.
TRI-POINT HOLDINGS
OWNER .
WAUKEE, IA 50007
TRI-POINT HOLDINGS -
RETAIL BUILDING
11.06.2018
TLS
ARCHITECT AND INTERIOR DESIGNER
119 SECOND STREET, PO BOX 169
POLK CITY, IA 50226
Tel. 515.984.3077
ETHOS DESIGN GROUP, INC.
MAA
MECHANICAL AND ELECTRICAL ENGINEER
STRUCTURAL ENGINEER
604 LOCUST STREET, SUITE 202
DES MOINES, IOWA 50309
Tel. 515.279.3900
SAUL ENGINEERING, INC.
413 TYLER STREET
POLK CITY, IA 50226
Tel. 515.473.0030
BUTLER ENGINEERING, INC.
CIVIL E N G I N E E R
2727 SW SNYDER BLVD.
ANKENY, IA 50023
Tel. 515.964.2020
SNYDER & ASSOCIATES, INC.
1
1
5TH CITY SITE PLAN SUBMITTAL
S&A: 118.0753
MAA
651 NE VENTURE DRIVE
N 89°47'30" E 270.95'S 00°12'30" E 240.00'N 00°12'30" W 240.00'S 89°47'30" W 270.95'
Subdrain
Rim=1034.07
Cleanout
F.L.=1028.26 18" RCP W
Rim=1032.91
F.L.=1028.39 18" RCP S
Intake=1032.19
Unable to Obtain FL N
F.L.=1028.52 18" RCP S
Intake=1032.13
18" RCP E
F.L.=1028.10
F.L.=1028.78 18" RCP N
Inlet=1031.46 S
Inlet=1031.58 E
Inlet=1031.59 N
Rim=1032.83
Inv=1015.53 8" TRUSS S
Rim=1033.88
Rim=1034.04
Cleanout
6"Subdrain
12"
8
7
8
8
8
7
TRASH
T
6"W6"W
SAN
6"W
H H
FFE=1034.8512"ST18"ST12"ST 12"ST15"ST15"ST
RDRD6"W
8"W8"WGGRDRDFUTURE PARKING FUTURE PARKING
DIMENSION PLAN CONSTRUCTION NOTES
0 20
FEET
PAVEMENT LEGEND
C200
50' BUILDING SETBACK
50' BUILDING SETBACK 60' BUILDING SETBACKPARKING STALLS
35 PROPOSED
Easement
30' Sanitary Sewer
PARKING STALLS
15 PROPOSED
28.0' B/B
17.0'24.0'17.0'10.2'TYP
9.0'
TYP
9.0'
9.0'9.0'31.0' B/B17.0'24.0'17.0'TYP
9.0'
9.0'9.0'TYP
9.0'6.0'6.0'11.0'34.8'4.0'TYP
9.0'
60.0'1.0'1.0'15.0'25.0' B/B
11.3'
DIMENSION PLAN
5
.0'
R
11.0'
NO SCALE VARIES1"R
4.5"
7.5"
2"R 6"PCC STANDARD CURB PCC SIDEWALK W/ INTEGRAL CURB
6"
NO SCALE
12"18"
VARIES
SIDEWALK
6
7
4
2 3 height: 0" to 2"
Drop curb
1'-0" min.
Curb opening
18"12"
Driveway width
NO SCALE
5
DETAIL B
2
7Back of curb
1 R
bar
reinforcing
#5 x 36"
1'-0"
TYPICAL SECTION
Curb
Driveway
SidewalkPr
o
pert
y line
TYPE A WITH RADII
as specified
Detail B
Refer to
curb
Back of
8
2
'E' joint
joint
'C' or 'E'
'B' joint
'C' joint
9
10
10
1'-0"
CONCRETE DRIVEWAY, TYPE A
C200
1
C200
2
C200
3
30.0'R15.0'RTYP5.0'5.0'R5.0'R 5.0'R(4,850 SF)
PROPOSED
(2,701 SF)
PROPOSED
(2,310 SF)
PROPOSED60'42'84'172'46'65.5'1.0'
70' Ingress/Egress Easement
(Bk 2017, Pg 23437)
Easement
50' Sanitary Sewer
Existing3.0'R10
.0'
R
25.0'R
1.0'
15.0'
R 5.0'R5.0'RFUTURE ROAD8.0'
8.0'
8
.0'
PREFINISHED METAL COPING
1/4" GALV. STEEL PLATE ON
2X2 GALV. STEEL FRAME W/
STIFFENER BREAKS
GREASE FITTINGS IN EACH
COLLAR - BOTH SIDES, TYP.
BRICK VENEER, SEE SPEC
PRE-FINISHED METAL PARAPET COPING
CONTROL JOINT IN BRICK
STONE VENEER, SEE SPEC
8" GALVANIZED STEEL
BOLLARD, CONCRETE
FILLED, TYP. 2
PRE-FINISHED METAL PARAPET COPING
CONTROL JOINT IN BRICK
STONE VENEER, SEE SPEC
8" GALVANIZED STEEL
BOLLARD, CONCRETE
FILLED, TYP. 2
PRE-FINISHED METAL PARAPET COPING
CONTROL JOINT IN BRICK
STONE VENEER, SEE SPEC
2'-0"2'-0"
2'-0"
2'-0"
2'-0"2'-0"
NO SCALEC200
4 TRASH ENCLOSURE 12.9'FRONT VIEW SIDE VIEW SIDE VIEW REAR VIEW
NE VENTURE DRIVE (PRIVATE)25.8' B/B25.0' B/B20.0' B/B25.0' B/B7.5'R6. SEE ARCHITECTURAL DRAWINGS FOR DETAILED BUILDING CONSTRUCTION INFORMATION.
A. TRASH ENCLOSURE. SEE DETAILS ON THIS SHEET AND ARCHITECTURAL PLANS FOR ADDITIONAL DETAILS.
5. SITE AMENITIES, PROVIDE THE FOLLOWING:
A. POLE MOUNTED VAN ACCESSIBLE PARKING SIGNAGE AS PER ADAAG REQUIREMENTS.
4. SIGNAGE, PROVIDE THE FOLLOWING:
C. PAINTED STATE OF IOWA APPROVED DISABLED SYMBOL AS PER ADAAG REQUIREMENTS.
B. 45° STRIPING AT 3' O.C. WHERE SHOWN.
A. 4" PAINTED PARKING STALL LINES, WHITE.
3. PAVEMENT MARKINGS, PROVIDE THE FOLLOWING:
J. DETECTABLE WARNING PANEL. COORDINATE MATERIAL AND COLOR WITH OWNER.
I. PEDESTRIAN RAMP WITH MAXIMUM SLOPE OF 8.33%.
H. CONNECT TO EXISTING PAVEMENT SUDAS TYPE A APPROACH.
G. PCC STOOP. SEE ARCHITECTURAL PLANS FOR DETAILS.
F. 6" STANDARD CURB, SEE DETAIL ON THIS SHEET.
E. 7" PCC PAVEMENT ON 12" DEPTH PREPARED SUBGRADE COMPACTED TO 95% STANDARD PROCTOR DENSITY.
DENSITY.
D. 6" DEPTH PCC PAVEMENT ON 12" DEPTH PREPARED SUBGRADE COMPACTED TO 95% STANDARD PROCTOR
DENSITY.
C. 5" DEPTH PCC PAVEMENT ON 12" DEPTH PREPARED SUBGRADE COMPACTED TO 95% STANDARD PROCTOR
B. INTEGRAL CURB. SEE DETAIL ON THIS SHEET.
DENSITY.
A. 4" DEPTH PCC SIDEWALK ON 6" DEPTH PREPARED SUBGRADE COMPACTED TO 95% STANDARD PROCTOR
2. PAVEMENTS, PROVIDE THE FOLLOWING:
CONSIDERED INCIDENTAL TO THE PROJECT.
UTILITY PROVIDER PRIOR TO CONSTRUCTION. ADJUSTMENTS OF UTILITY APPURTENANCE TO FINISH GRADE IS
B. EXISTING UTILITIES. COORDINATE ANY NECESSARY RELOCATIONS OR ADJUSTMENTS WITH THE OWNER AND
A. EXISTING PAVEMENTS TO REMAIN.
ADDITIONAL COMPENSATION.
SHOWN FOR REMOVAL SHALL BE REQUIRED BY THE CONTRACTOR TO THE OWNERS SPECIFICATIONS WITHOUT
1. PROTECT ALL SITE FEATURES NOT SCHEDULED FOR DEMOLITION OR MODIFICATION. ANY DAMAGES TO ITEMS NOT
8.0'
5.9'
6.0'
(BK:2017, PG:23440)
10' GAS MAIN EASEMENT
11.0'14.0'12.0'
2H 1A
1B
2A
2B2B
2B 2B
2C
2C
2C2C
2C
3A TYP 3A TYP
3A TYP3ATYP
3B
3B
3C
3C
4A
4A
5A
666
2D
2D
2E
2F
2F 2F
2F
2F
2F
2F
2G 2G
2G
2G
2G
2I
2I
2I
2I
1B
1B
1B
1B
2H
2C
2A
2A
2A
2I
2I
2I
2I
2J
2J
S H E E T T I T L E .
S H E E T N O .
C
ISSUE DATE :
PROJECT
NO :
D R A W I N G I S S U E I N F O R M A T I O N .
M A N A G E M E N T I N F O R M A T I O N .
M A R K D E S C R I P TI O ND A T E
P R O J E C T N A M E .
DRAWN BY :
PRINCIPAL
IN CHARGE :ARCHITECT :
PROJECT
CHECKED BY :
2 3 4 5
A
B
C
D D
C
B
A
2 3 4 5
ISSUE FOR :
THESE DOCUMENTS HAVE BEEN PREPARED SPECIFICALLY
FOR THE PROJECT REFERENCED ABOVE. THEY ARE NOT TO
BE USED FOR OTHER PROJECTS OR IN LOCATIONS OTHER
THAN SPECIFIED WITHOUT THE WRITTEN APPROVAL AND
PARTICIPATION OF ETHOS DESIGN GROUP, INC.
Office: 515.984.3077 Website: www.ethos.archi
119 Second Street, PO Box 169 Polk City, IA 50226
2018 ETHOS DESIGN GROUP, INC.
TRI-POINT HOLDINGS
OWNER .
WAUKEE, IA 50007
TRI-POINT HOLDINGS -
RETAIL BUILDING
11.06.2018
TLS
ARCHITECT AND INTERIOR DESIGNER
119 SECOND STREET, PO BOX 169
POLK CITY, IA 50226
Tel. 515.984.3077
ETHOS DESIGN GROUP, INC.
MAA
MECHANICAL AND ELECTRICAL ENGINEER
STRUCTURAL ENGINEER
604 LOCUST STREET, SUITE 202
DES MOINES, IOWA 50309
Tel. 515.279.3900
SAUL ENGINEERING, INC.
413 TYLER STREET
POLK CITY, IA 50226
Tel. 515.473.0030
BUTLER ENGINEERING, INC.
CIVIL E N G I N E E R
2727 SW SNYDER BLVD.
ANKENY, IA 50023
Tel. 515.964.2020
SNYDER & ASSOCIATES, INC.
1
1
5TH CITY SITE PLAN SUBMITTAL
S&A: 118.0753
MAA
651 NE VENTURE DRIVE
N 89°47'30" E 270.95'S 00°12'30" E 240.00'N 00°12'30" W 240.00'S 89°47'30" W 270.95'
Subdrain
Rim=1034.07
Cleanout
F.L.=1028.26 18" RCP W
Rim=1032.91
F.L.=1028.39 18" RCP S
Intake=1032.19
Unable to Obtain FL N
F.L.=1028.52 18" RCP S
Intake=1032.13
18" RCP E
F.L.=1028.10
F.L.=1028.78 18" RCP N
Inlet=1031.46 S
Inlet=1031.58 E
Inlet=1031.59 N
Rim=1032.83
Inv=1015.53 8" TRUSS S
Rim=1033.88
Rim=1034.04
Cleanout
6"Subdrain
12"
8
7
8
8
8
7
TRASH
T
6"W6"W
6"W
H HRDRD 6"W
8"W8"WGGRDRDFUTURE PARKING FUTURE PARKING
0 20
FEET
C300
UTILITY PLAN
50' BUILDING SETBACK
50' BUILDING SETBACK 60' BUILDING SETBACKPARKING STALLS
32 PROPOSED
Easement
30' Sanitary Sewer
Easement
50' Sanitary Sewer
Existing
UTILITY PLAN CONSTRUCTION NOTES
1028.75
SAN @ 2.0%
39 LF OF 6"
INV=1028.36
CONNECT TO EXISTING
CORE DRILL AND
89 LF OF 12" ST @ 0.5%
95 LF OF 15" ST @ 0.5%
INV=1028.50(OUT SW)
INV=1028.60(IN N,E)
RIM=1032.80
MANHOLE TYPE SW-401
ST-4A
INV=1029.05(OUT W)
INV=1029.15(IN E)
RIM=1032.70
INTAKE TYPE SW-511
ST-4
INV=1029.61
RIM=1033.10
INTAKE TYPE SW-511
ST-3
92 LF OF 12" ST @ 0.5%
INV=1029.27(OUT S)
INV=1029.37(IN NE)
RIM=1032.90
MANHOLE TYPE SW-401
ST-2A
133 LF OF 15" ST @ 0.5%ST @ 0.5%27 LF OF 18" INV=1029.85 (OUT W)
INV=1029.95 (IN S)
RIM=1033.15
INTAKE TYPE SW-511
ST-2
INV=1030.55
RIM=1034.65
CLEANOUT
ST-1
(4,850 SF)
PROPOSED
(2,701 SF)
PROPOSED
(2,310 SF)
PROPOSED60'42'84'172'46'FUTURE ROAD150' Proposed Hydrant Coverage
70' Ingress/Egress Easement
TP WATER=1027.07
BP SAN=1028.57
NE VENTURE DRIVE (PRIVATE)
TP WATER=1029.15
BP STORM=1030.651.5%12" ST @ 48 LF OF 11. ELECTRICAL METERS. REFER TO ARCHITECTURAL AND MECHANICAL PLANS FOR DETAILS.
10. GAS SERVICE COORDINATE INSTALLATION WITH MECHANICAL DRAWINGS AND SERVICE PROVIDER.
MECHANICAL PLANS FOR DETAILS.
9. UTILITY STORAGE ROOM (FIRE RISER LOCATION). COORDINATE WITH ARCHITECTURAL AND
8. GAS METERS. COORDINATE LOCATION WITH ARCHITECTURAL AND MECHANICAL PLANS.
PROVIDER PRIOR TO CONSTRUCTION.
B. PROVIDE TRANSFORMER LOCATION. COORDINATE WITH OWNER AND FRANCHISE UTILITY
FOR ADDITIONAL INFORMATION.
A. SITE LIGHTING LOCATIONS SHOWN FOR COORDINATION PURPOSES ONLY. SEE ELECTRICAL PLAN
7. SITE ELECTRICAL, PROVIDE THE FOLLOWING:
WITH UTILITY SERVICE PROVIDERS PRIOR TO START OF CONSTRUCTION.
6. CONTRACTOR TO COORDINATE NATURAL GAS, ELECTRICAL AND COMMUNICATION/ DATA SERVICES
BETWEEN UTILITIES.
5. CONTRACTOR TO VERIFY ALL UTILITY CROSSINGS AND MAINTAIN MINIMUM 18" CLEARANCE
C. AT GRADE ROOF DRAIN LOCATION. SEE ARCHITECTURAL AND MECHANICAL PLANS FOR DETAILS.
B. 6" ROOF DRAIN COLLECTION LINE AT 1% MINIMUM.
ARCHITECTURAL PLANS PRIOR TO CONSTRUCTION.
A. CONNECT TO INTERNAL BUILDING ROOF DRAIN. VERIFY LOCATION AND SIZE WITH
4. STORM SEWER PROVIDE THE FOLLOWING:
DETAILS.
H. FIRE DEPARTMENT CONNECTION. REFER TO ARCHITECTURAL AND MECHANICAL PLANS FOR
G. REMOVE AND RELOCATE EXISTING HYDRANT.
F. 6"x6" TEE WITH REDUCER AS NECESSARY.
E. 2" DOMESTIC WATER SERVICE WITH CURB STOP AND 2" VALVE.
D. RELOCATED HYDRANT ASSEMBLY.
PLANS FOR ADDITIONAL INFORMATION.
C. BUILDING SERVICE CONNECTION. COORDINATE WITH ARCHITECT'S MECHANICAL AND PLUMBING
LOCATION AND ELEVATION WITH MECHANICAL PLANS.
B. 6" WATER SERVICE LINE WITH VALVE AND FITTINGS AND BENDS AS NECESSARY. COORDINATE
AND VERIFY LOCATION, SIZE AND ELEVATION PRIOR TO CONSTRUCTION.
A. CONNECT TO EXISTING 6'' WATER MAIN. COORDINATE REQUIREMENTS WITH CITY OF WAUKEE
PLAN AND AS FOLLOWS:
3. WATER SERVICE 5.5' MINIMUM DEPTH. PROVIDE WATER PIPE AND STRUCTURES AS NOTED ON
PLUMBING PLANS PRIOR TO CONSTRUCTION.
ADDITIONAL INFORMATION. CONTRACTOR SHALL VERIFY ALL FLOWLINE INFORMATION WITH
D. BUILDING SERVICE CONNECTION. COORDINATE WITH ARCHITECT'S PLUMBING PLANS FOR
C. SANITARY CLEANOUT.
B. 6" PVC SANITARY SEWER SERVICE AT MINIMUM 1.0%.
PRIOR TO CONSTRUCTION.
CONTRACTOR TO VERIFY LOCATION AND ELEVATION OF EXISTING SANITARY SEWER STUB
A. CONNECT TO EXISTING SANITARY SEWER STUB AS PER CITY OF WAUKEE STANDARDS.
PLAN AND AS FOLLOWS:
2. SANITARY SEWER SERVICE. PROVIDE SANITARY SEWER PIPE AND STRUCTURES AS NOTED ON
1. REFER TO SHEET C200 FOR PROTECTION OF EXISTING FEATURES.
(BK:2017, PG:23440)
10' GAS MAIN EASEMENT
7B
7A
7A
7A 7A
7A
7A
7A
7A
6 6 6 3D
3G
3A
2A2B
2D
2C
3B
5
3E
3B
3C
4A
4A
4B 4B
3F
5
3H
8 9
10
5
11
3B
4C
4C
7A
7A 7A
S H E E T T I T L E .
S H E E T N O .
C
ISSUE DATE :
PROJECT
NO :
D R A W I N G I S S U E I N F O R M A T I O N .
M A N A G E M E N T I N F O R M A T I O N .
M A R K D E S C R I P TI O ND A T E
P R O J E C T N A M E .
DRAWN BY :
PRINCIPAL
IN CHARGE :ARCHITECT :
PROJECT
CHECKED BY :
2 3 4 5
A
B
C
D D
C
B
A
2 3 4 5
ISSUE FOR :
THESE DOCUMENTS HAVE BEEN PREPARED SPECIFICALLY
FOR THE PROJECT REFERENCED ABOVE. THEY ARE NOT TO
BE USED FOR OTHER PROJECTS OR IN LOCATIONS OTHER
THAN SPECIFIED WITHOUT THE WRITTEN APPROVAL AND
PARTICIPATION OF ETHOS DESIGN GROUP, INC.
Office: 515.984.3077 Website: www.ethos.archi
119 Second Street, PO Box 169 Polk City, IA 50226
2018 ETHOS DESIGN GROUP, INC.
TRI-POINT HOLDINGS
OWNER .
WAUKEE, IA 50007
TRI-POINT HOLDINGS -
RETAIL BUILDING
11.06.2018
TLS
ARCHITECT AND INTERIOR DESIGNER
119 SECOND STREET, PO BOX 169
POLK CITY, IA 50226
Tel. 515.984.3077
ETHOS DESIGN GROUP, INC.
MAA
MECHANICAL AND ELECTRICAL ENGINEER
STRUCTURAL ENGINEER
604 LOCUST STREET, SUITE 202
DES MOINES, IOWA 50309
Tel. 515.279.3900
SAUL ENGINEERING, INC.
413 TYLER STREET
POLK CITY, IA 50226
Tel. 515.473.0030
BUTLER ENGINEERING, INC.
CIVIL E N G I N E E R
2727 SW SNYDER BLVD.
ANKENY, IA 50023
Tel. 515.964.2020
SNYDER & ASSOCIATES, INC.
1
1
5TH CITY SITE PLAN SUBMITTAL
S&A: 118.0753
MAA
651 NE VENTURE DRIVE
N 89°47'30" E 270.95'S 00°12'30" E 240.00'N 00°12'30" W 240.00'S 89°47'30" W 270.95'
Subdrain
Rim=1034.07
Cleanout
F.L.=1028.26 18" RCP W
Rim=1032.91
F.L.=1028.39 18" RCP S
Intake=1032.19
Unable to Obtain FL N
F.L.=1028.52 18" RCP S
Intake=1032.13
18" RCP E
F.L.=1028.10
F.L.=1028.78 18" RCP N
Inlet=1031.46 S
Inlet=1031.58 E
Inlet=1031.59 N
Rim=1032.83
Inv=1015.53 8" TRUSS S
Rim=1033.88
Rim=1034.04
Cleanout
6"Subdrain
12"
8
7
8
8
8
7T
6"W6"W
SAN
6"W
H H12"ST18"ST12"ST 12"ST15"ST15"ST
RDRD6"W
8"W8"WGGRDRDFUTURE PARKING FUTURE PARKING
102810291
0
3
0
10
3
1
1032
10321032 103310331033103310331033103410341034
1034
10
3
4
103410341
0
3
4
10341034
1033.40
1033.20
1033.35
1034.07
1034.74T/C
1033.97
1034.61T/C
1032.30 (1032.44)1032.45
1032.50
1032.58
1032.59(1032.61)1032.60
LP
1032.80
1032.80 1032.90
(1032.92)10331033
10
3
3 10331033.05 1033.05 1033.10
LP
1033.15G
1033.65T/C
LP 1033.24G1033.74T/C1033.25G
1033.75T/C
1033.30
1033.31
1033.32G
1033.82T/C 1033.35G1033.85T/C1033.35G
1033.85T/C
1033.35
1033.85T/C1033.401033.40
1033.40
(1033.40)1033.441033.451033.45
1033.45G
1033.95T/C
1033.50
1034.00T/C 1033.531033.55
1033.55
1034.05T/C1033.601033.601033.501033.60G
1034.10T/C
1033.60
HP
1033.65
(1033.66)1033.701033.70G1034.20T/C1033.70G1034.20T/C1033.701033.701033.801033.70
1034.20T/C
1033.70G
1034.20T/C
HP
1033.751033.751033.75G
1034.25T/C
1033.80G
1034.30T/C
1033.80G
1034.30T/C
1033.80 1033.801034.30T/C1033.80G1034.30T
/
C
1033.80
1033.81
(1033.83)
1033.80G
1034.30T/C1033.851033.851033.851033.851033.85G
1034.35T/C
1033.85
1034.35T/C 1033.871034.37T/C1033.90
1033.94 1033.951033.951034.45TC1033.95
1034.45T/C
1034
1034103410341034
1034
1034
1034
10341034.00G1034.50T/C1034.05G
1034.55T/C1034.15G1034.65T/C1034.051034.051034.051034.55T/C1034.10G
1034.60T/C1034.101034.10G1034.60T/C1034.20G
1034.70T/C
1034.10G
1034.60T/C
1034.10
1034.101034.151034.151034.251034.301034.30G
1034.80T/C
1034.30
1034.35
1034.35 1034.40
1034.40 1034.351034.471034.501034.501034.50
1034.50
1034.50 1034.501034.501034.50 1034.601034.60
1034.60
1034.60
1034.651034.60
1034.60
1034.65
1034.64G
1035.14T/C
1034.75
1034.701034.651034.55
1034.801034.70
1034.80
1034.80
1034.85
1034.851034.851034.80 1034.751034.75
1034.80
1034.85
1034.85
1034.00
1034.50
1033.931034.60T/C
1
0
3
3
.83
1
0
3
4
.
5
0
T
/
C
0 20
FEET
GRADING NOTES
C400
GRADING PLAN
50' BUILDING SETBACK
50' BUILDING SETBACK 60' BUILDING SETBACKPARKING STALLS
31 PROPOSED
Easement
30' Sanitary Sewer
PARKING STALLS
15 PROPOSED
Easement
50' Sanitary Sewer
Existing60'(2,310 SF)
PROPOSED
42'46'
(2,701 SF)
PROPOSED
172'
84'
(4,850 SF)
PROPOSED
0.0%
0.0%1.7%1.7%1.7%3.9%
3.9%
5.6%
5.6%1.7%1.1%
1.1%1.7%1.7%6.7%
6.7%1.7%5.6%
5.6%1.7%1.7%0.5%
0.5%
1.7%
1.7%1.7%1.7%1.7%1.7%1.7%1.7%
1.7%
3.0%2.0%6.0%2.0%2.5%5.0%1.5%2.5%2.3%1.9%5.0%2.5%3.0%2.0%DETAIL A
SCALE: 1"=10'
DETAIL B
SCALE: 1"=10'
DETAIL C
SCALE: 1"=10'
DETAIL D
SCALE: 1"=10'1033.441033.401033.451033.551033.801034.30T/C1033.70G1034.20T/C1033.701033.601033.70G1034.20T/C1034.251034.501034.301033.701033.801034.501034.351033.531034.301033.70
1034.20T/C
1033.40
1034.60
1033.201034.501034.151034.151034.651034.751033.871034.37T/C1033.951034.45TC1034.051034.051034.051034.55T/C1034.15G1034.65T/C1033.851033.851033.851033.751033.851034.47FFE=1034.85
FUTURE ROAD70' Ingress/Egress Easement
DETAIL A
DETAIL CDETAIL B
DETAIL D
2.0%5.0%5.0%4.0%4.0%5.0%5.0%4.0%2.0%25%
25%
5.0%1033.571033.631034.251034.201033.80G1034.30T/C1034.351.0%7.9%2.0%
2.0%0.8%7.8%0.8%1033.821033.881033.931033.871034.031033.971034.451034.451034.451034.301034.351.0%1.0%1.0%5.3%6.5%6.0%6.0%1.0%
1.0%
1.25%
1.25%
1.25%
1033.05
1033.001033.08
1033.58 1033.50
6.25%6.25%1.0%
1.0%
1033.351033.801033.901033.701033.806.25%1.9%
1.25%1.25%1.25%1.25%
1033.70
100-yr Ponding Depth
1033.60
100-yr Ponding Depth
1033.20
100-yr Ponding Depth
OVERFLOW OVERFLOW
OVERFLOW
NE VENTURE DRIVE (PRIVATE)FUTURE ROAD16%
25%5.3%1033.581033.66
1.0%1.0%1.0%1034.601034.500.6%1.9%1.25%
0.0%1034.251034.401034.351.0%1.0%1
.2
5%1033.101033.201.25%1033.691033.751.0%(BK:2017, PG:23440)
10' GAS MAIN EASEMENT
0/14 DAY REQUIREMENT.
SCHEDULED IN AN AREA DURING THE FOLLOWING 14 DAYS TO MEET GENERAL PERMIT NO.2
3. EROSION CONTROL: SEEDING STABILIZATION SHOULD BE INSTALLED IMMEDIATELY IF WORK IS NOT
PLACE TOPSOIL OVER ALL AREAS DISTURBED.
2. ANY EXCESS CUT TO BE SPREAD ON SITE AS DIRECTED BY ENGINEER DURING CONSTRUCTION.
RESPREAD TO MINIMUM 8" DEPTH TO FINISH GRADES PER 2018 SUDAS SPEC 2010.
1. CONTRACTOR TO STRIP AND STOCKPILE TOPSOIL ON ALL AREAS TO BE CUT OR FILLED.
S H E E T T I T L E .
S H E E T N O .
C
ISSUE DATE :
PROJECT
NO :
D R A W I N G I S S U E I N F O R M A T I O N .
M A N A G E M E N T I N F O R M A T I O N .
M A R K D E S C R I P TI O ND A T E
P R O J E C T N A M E .
DRAWN BY :
PRINCIPAL
IN CHARGE :ARCHITECT :
PROJECT
CHECKED BY :
2 3 4 5
A
B
C
D D
C
B
A
2 3 4 5
ISSUE FOR :
THESE DOCUMENTS HAVE BEEN PREPARED SPECIFICALLY
FOR THE PROJECT REFERENCED ABOVE. THEY ARE NOT TO
BE USED FOR OTHER PROJECTS OR IN LOCATIONS OTHER
THAN SPECIFIED WITHOUT THE WRITTEN APPROVAL AND
PARTICIPATION OF ETHOS DESIGN GROUP, INC.
Office: 515.984.3077 Website: www.ethos.archi
119 Second Street, PO Box 169 Polk City, IA 50226
2018 ETHOS DESIGN GROUP, INC.
TRI-POINT HOLDINGS
OWNER .
WAUKEE, IA 50007
TRI-POINT HOLDINGS -
RETAIL BUILDING
11.06.2018
TLS
ARCHITECT AND INTERIOR DESIGNER
119 SECOND STREET, PO BOX 169
POLK CITY, IA 50226
Tel. 515.984.3077
ETHOS DESIGN GROUP, INC.
MAA
MECHANICAL AND ELECTRICAL ENGINEER
STRUCTURAL ENGINEER
604 LOCUST STREET, SUITE 202
DES MOINES, IOWA 50309
Tel. 515.279.3900
SAUL ENGINEERING, INC.
413 TYLER STREET
POLK CITY, IA 50226
Tel. 515.473.0030
BUTLER ENGINEERING, INC.
CIVIL E N G I N E E R
2727 SW SNYDER BLVD.
ANKENY, IA 50023
Tel. 515.964.2020
SNYDER & ASSOCIATES, INC.
1
1
5TH CITY SITE PLAN SUBMITTAL
S&A: 118.0753
MAA
651 NE VENTURE DRIVE
N 89°47'30" E 270.95'S 00°12'30" E 240.00'N 00°12'30" W 240.00'S 89°47'30" W 270.95'
Subdrain
Rim=1034.07
Cleanout
F.L.=1028.26 18" RCP W
Rim=1032.91
F.L.=1028.39 18" RCP S
Intake=1032.19
Unable to Obtain FL N
F.L.=1028.52 18" RCP S
Intake=1032.13
18" RCP E
F.L.=1028.10
F.L.=1028.78 18" RCP N
Inlet=1031.46 S
Inlet=1031.58 E
Inlet=1031.59 N
Rim=1032.83
Inv=1015.53 8" TRUSS S
Rim=1033.88
Rim=1034.04
Cleanout
6"Subdrain
12"
8
7
8
8
8
7T
6"W6"W
SAN
6"W
H H12"ST18"ST12"ST 12"ST15"ST15"ST
RDRD6"W
8"W8"WGGRDRDFUTURE PARKING FUTURE PARKING
102810291
0
3
0
10
3
1
1032
10321032 103310331033103310331033103410341034
1034
10
3
4
103410341
0
3
4
1034103410331033
10
3
3 10331034
1034103410341034
1034
1034
1034
10340 20
FEET
QUANTITIES
(5'-0" max.)
Post Spacing
(5'-0" max.)
Post Spacing
Variable (20'-0" for a normal 10'-0" wide ditch.)
TYPICAL SILT FENCE DITCH CHECKForeslope Backslope
1
2" min.
20" min.
ATTACHMENT TO POST
Fabric
Post
Cable Ties
Wire or
to adequately support fence.
concentration areas, or as required
Reduce post spacing to 5'-0" at water
folded below the ground line).
of 6 inches deep (fabric may be
Insert 12 inches of fabric a minimum
2
1
24"
36"
8'-0" Spacing
DETAILS OF SILT FENCE ON LONGITUDINAL SLOPES
1
2
Ground Line
Fabric
See plans for spacing.
(Profile View)
TYPICAL SILT FENCE INSTALLATION ON LONGITUDINAL SLOPES
Flow
1
1
4'-0" min.
Fence Post
'T' Steel
Ground line
Fabric
(600'-0" if slope is flatter than 5%)
200'-0" max. length per section
(Plan View)
TYPICAL SILT FENCE INSTALLATION ON LONGITUDINAL SLOPES
Ground Contours
ground contour.
Install parallel to
individual section of silt fence.
Install "J-hook" at each end of an
C500
PLAN
SEDIMENT CONTROL
EROSION AND
50' BUILDING SETBACK
50' BUILDING SETBACK 60' BUILDING SETBACKPARKING STALLS
31 PROPOSED
Easement
30' Sanitary Sewer
PARKING STALLS
31 PROPOSED
Easement
50' Sanitary Sewer
Existing
EROSION CONTROL PLAN GENERAL NOTES
SILT FENCE TYP.
SILT FENCE TYP.
SILT FENCE TYP.
(4,850 SF)
PROPOSED
(2,701 SF)
PROPOSED
(2,310 SF)
PROPOSED60'42'84'172'46'FUTURE ROAD70' Ingress/Egress Easement
AREA
STAGING
H. STABILIZED CONSTRUCTION ENTRANCE. REFER TO DETAIL ON THIS SHEET.
2.02, D (URBAN TEMPORARY EROSION CONTROL MIXTURE).
2018 SUDAS STANDARD SPECIFICATION SECTION 9010. SEEDING TO BE PER SECTION 9010,
G. CONTRACTOR TO PROVIDE EROSION CONTROL SEEDING, FERTILIZING AND MULCHING BASED ON
DAY AND PRIOR TO A RAIN EVENT.
DRIVEWAYS, AND SIDEWALKS CAUSED BY CONSTRUCTION ACTIVITIES AT THE END OF EACH
F. THE CONTRACTOR IS RESPONSIBLE FOR CLEANING DIRT AND DEBRIS FROM STREETS,
RESPREAD TO MINIMUM 8" DEPTH TO FINISH GRADES.
E. CONTRACTOR TO STRIP AND STOCKPILE TOPSOIL FROM ALL AREAS TO BE CUT OR FILLED.
OF STRUCTURE AND INCLUDE FLARED END SECTION.
D. ALL STORM SEWER PIPE LENGTHS ARE MEASURED FROM CENTER OF STRUCTURE TO CENTER
OF PAVING SLAB (GUTTER), UNLESS OTHERWISE NOTED.
C. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS SHOWN ARE FINISHED GRADES AND/OR TOP
EXPENSE. COORDINATE AND COOPERATE WITH UTILITY COMPANIES DURING CONSTRUCTION.
THE CONTRACTOR'S CARELESSNESS SHALL BE CORRECTED AT THE CONTRACTOR'S
AVOID DAMAGE TO UTILITIES AND SERVICES DURING CONSTRUCTION. ANY DAMAGE DUE TO
RESPONSIBLE FOR DETERMINING EXISTENCE, EXACT LOCATION AND DEPTH OF ALL UTILITIES.
B. NOTIFY UTILITY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION. CONTRACTOR IS
INDICATED.
FURTHER DOES NOT WARRANT THAT THE UTILITIES SHOWN ARE IN THE EXACT LOCATION
ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEY
OBTAINED. THE SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES SHOWN COMPRISE
THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR RECORDS
A. UTILITY WARNING:
LIMIT
DISTURBANCE
LIMIT
DISTURBANCE
LIMIT
DISTURBANCE
LIMIT
DISTURBANCE
SEDIMENT BASKET
SEDIMENT BASKET
1.21 ACAREA OF DISTURBANCE
2 EASEDIMENT BASKET
0.40 ACSOD
835 LFSILT FENCE
NE VENTURE DRIVE (PRIVATE)
CREEK
DETENTION TO WALNUT
LOCATION WEST
ULTIMATE DISCHARGE
AREA
STOCKPILE
TOPSOIL
AREA
MATERIALS STORAGE
WASHOUT/WASTE
CONCRETE
(BK:2017, PG:23440)
10' GAS MAIN EASEMENT
TO WALNUT CREEK
ULTIMATE DISCHARGE
DETENTION BASIN.
EAST TO REGIONAL
OVERLAND FLOW
C500
1 SILT FENCE
NO SCALE
C500
1
NO SCALE
GRADATION 13) W/ ENGINEERING FABRIC
(IOWA DOT SECTION 4122
6" MIN. DEPTH MACADUM
STABILIZED CONSTRUCTION ENTRANCE
ENTRANCE/EXIT
CONSTRUCTION
STABILIZED
STABILIZED CONSTRUCTION ENTRANCE/EXIT
S H E E T T I T L E .
S H E E T N O .
C
ISSUE DATE :
PROJECT
NO :
D R A W I N G I S S U E I N F O R M A T I O N .
M A N A G E M E N T I N F O R M A T I O N .
M A R K D E S C R I P TI O ND A T E
P R O J E C T N A M E .
DRAWN BY :
PRINCIPAL
IN CHARGE :ARCHITECT :
PROJECT
CHECKED BY :
2 3 4 5
A
B
C
D D
C
B
A
2 3 4 5
ISSUE FOR :
THESE DOCUMENTS HAVE BEEN PREPARED SPECIFICALLY
FOR THE PROJECT REFERENCED ABOVE. THEY ARE NOT TO
BE USED FOR OTHER PROJECTS OR IN LOCATIONS OTHER
THAN SPECIFIED WITHOUT THE WRITTEN APPROVAL AND
PARTICIPATION OF ETHOS DESIGN GROUP, INC.
Office: 515.984.3077 Website: www.ethos.archi
119 Second Street, PO Box 169 Polk City, IA 50226
2018 ETHOS DESIGN GROUP, INC.
TRI-POINT HOLDINGS
OWNER .
WAUKEE, IA 50007
TRI-POINT HOLDINGS -
RETAIL BUILDING
11.06.2018
TLS
ARCHITECT AND INTERIOR DESIGNER
119 SECOND STREET, PO BOX 169
POLK CITY, IA 50226
Tel. 515.984.3077
ETHOS DESIGN GROUP, INC.
MAA
MECHANICAL AND ELECTRICAL ENGINEER
STRUCTURAL ENGINEER
604 LOCUST STREET, SUITE 202
DES MOINES, IOWA 50309
Tel. 515.279.3900
SAUL ENGINEERING, INC.
413 TYLER STREET
POLK CITY, IA 50226
Tel. 515.473.0030
BUTLER ENGINEERING, INC.
CIVIL E N G I N E E R
2727 SW SNYDER BLVD.
ANKENY, IA 50023
Tel. 515.964.2020
SNYDER & ASSOCIATES, INC.
1
1
5TH CITY SITE PLAN SUBMITTAL
S&A: 118.0753
MAA
651 NE VENTURE DRIVE
N 89°47'30" E 270.95'S 00°12'30" E 240.00'N 00°12'30" W 240.00'S 89°47'30" W 270.95'
F.L.=1028.26 18" RCP W
Rim=1032.91
F.L.=1028.39 18" RCP S
Intake=1032.19
Inv=1015.53 8" TRUSS S
Rim=1033.88
Rim=1034.04
Cleanout
6"Subdrain
12"
8
7
8
8
8
7T
6"W6"W
SAN
6"W
H H12"ST18"ST12"ST 12"ST15"ST15"ST
RDRD6"W
RDRDFUTURE PARKING FUTURE PARKING
103210331033103310331033103410
3
4
10341
0
3
4
10341034
0 20
FEET
PLANTING PLAN GENERAL NOTES
LANDSCAPE REQUIREMENTS
PLANTING PLAN CONSTRUCTION NOTES
BOTANICAL NAMEKEY COMMON NAME COMMENTS
TREESB&B
B&B
GT
QTY
Gledistia triacanthos 'Draves'
NOTE: IN THE EVENT OF A DISCREPANCY BETWEEN THE SCHEDULE QUANTITIES AND THE PLAN QUANTITIES THE PLAN QUANTITIES SHALL PREVAIL.
SIZE (AT INSTALL)SIZE (MATURITY)
Gymnocladus dioica KENTUCKY COFFEE TREEGD
CA Calamagrostis x acutiflora 'Karl Foerster'KARL FOERSTER GRASS 28" Ht.CONT. (3' O.C.)
Juniperus chinensis 'Sea Green'SEA GREEN JUNIPER 24" Ht.CONT. (5' O.C.)JC
5
3
26
6
60' HT.
45' HT.
5' HT.
6' HT.
PO 12 5-6' HT.CONT. (5' O.C.)Physocarpus opulifolius 'Seward'36" Ht.
CB 12 'IVORY HALO' DOGWOOD 36" Ht.5-6' HT.CONT. (5' O.C.)Cornus alba 'Bailhalo'
HH 27 12" Ht.CONT. (1' O.C.)'HAPPY RETURNS' DAYLILYHemerocallis x 'Happy Returns'1' HT.
6''
1
1
MATERIAL
FLAGGING
NYLON STRAP
GROMMETED
DETAILS
SEE PLANTING PIT
STEEL POSTS
(Trees 2 1/2 inch diameter or smaller)
STAKING PLAN
TO SOUTHWEST
PLACE ON STAKE
TO SOUTHWEST
PLACE ON STAKE
(2'-0" MIN.)
TREE HEIGHT
1/4 TO 1/3
6"
(Trees larger than 2 1/2 inch diameter)
STAKING PLAN
branch.
Wrap trunk from ground line to first
(4'-0" MIN.)
TREE HEIGHT
1/2 TO 2/3
DECIDUOUS TREE STAKING DETAIL
NO SCALE6
1 PLANTING PIT DETAILS
NO SCALE6
2
SLOPE PLANTING PIT DETAIL
EXISTING SLOPE
FINISH GRADE
TREE OR SHRUB
ROOT BALL
BEGIN TRANSITION AT EDGE OF
2:1 MAXIMUM TRANSITION SLOPE.
SCARIFY SIDES OF PIT
MINIMUM 6' DIAMETER, 3" DEPTH MULCH RING
BEYOND EDGE OF ROOT BALL
3" HEIGHT WATER RETENTION BERM
MINIMUM FOR SHRUBS
2X ROOTBALL
MINIMUM FOR TREES
3X ROOTBALL
ROOT SYSTEM
OR CONTAINER
DEPTH OF ROOT BALL
BASKET MINIMUM.
MINIMUM TOP 1/2 OF BURLAP AND WIRE
BALLED AND BURLAP (B&B) PLANTS REMOVE
MATERIAL. REMOVE ALL TWINE. FOR
IMPEDE THE GROWTH OF THE PLANT
CONTAINERS OR OTHER MATERIAL THAT WILL
REMOVE ALL NON-BIODEGRADABLE MATERIAL,
PRIOR TO INSTALLATION.
VERIFY LOCATION OF ROOT COLLAR AND ROOT FLARE
LOCATED AT TOP OF ROOTBALL. CONTRACTOR TO
2" OF TRUNK. ROOT COLLAR IS NOT ALWAYS
FINISH GRADE. DO NOT PLACE MULCH WITHIN
ROOT COLLAR AND ROOT FLARE MUST BE VISIBLE AT
PLACE ROOT BALL ON UNDISTURBED SOIL
Root Ball Diameter 1 1/2 to 2 Times
FINISH GRADE
SCARIFY SIDES OF PIT
TYPICAL PLANTING PIT DETAIL
BEYOND EDGE OF ROOT BALL
3" HEIGHT WATER RETENTION BERM
MINIMUM FOR SHRUBS
2X ROOTBALL
MINIMUM FOR TREES
3X ROOTBALL
ROOT SYSTEM
OR CONTAINER
DEPTH OF ROOT BALL
BASKET MINIMUM.
MINIMUM TOP 1/2 OF BURLAP AND WIRE
BALLED AND BURLAP (B&B) PLANTS REMOVE
MATERIAL. REMOVE ALL TWINE. FOR
IMPEDE THE GROWTH OF THE PLANT
CONTAINERS OR OTHER MATERIAL THAT WILL
REMOVE ALL NON-BIODEGRADABLE MATERIAL,
MINIMUM 6' DIAMETER, 3" DEPTH MULCH RING
PRIOR TO INSTALLATION.
VERIFY LOCATION OF ROOT COLLAR AND ROOT FLARE
LOCATED AT TOP OF ROOTBALL. CONTRACTOR TO
2" OF TRUNK. ROOT COLLAR IS NOT ALWAYS
FINISH GRADE. DO NOT PLACE MULCH WITHIN
ROOT COLLAR AND ROOT FLARE MUST BE VISIBLE AT
PLACE ROOT BALL ON UNDISTURBED SOIL
C600
PLANTING PLAN
PLANT SCHEDULE
E. ALL TREES TO BE PLANTED A MINIMUM OF 5 FEET FROM UTILITIES, PROPERTY LINES, FIRE HYDRANTS AND PAVEMENTS. NOTIFY THE OWNERS REPRESENTATIVE IF FIELD ADJUSTMENTS ARE NECESSARY.
ASSUME RESPONSIBILITY FOR MAINTENANCE ONCE THE WARRANTY PERIOD EXPIRES.
REPLACEMENTS OF PLANTS SHALL MEET MINIMIUM REQUIREMENTS SET FORTH IN THE ORIGINAL PLANTING. CONTRACTOR IS RESPONSIBLE FOR MAINTENACE FOR WARRANTY PERIOD. OWNER SHALL
D. CONTRACTOR SHALL GUARANTEE ALL PLANT MATERIAL FOR THE DURATION OF THE WARRANTY PERIOD. WARRANTY PERIOD SHALL BE ONE YEAR FROM THE DATE OF FINAL PROJECT ACCEPTANCE.
BY THE LANDSCAPE ARCHITECT OR OWNER'S REPRESENTATIVE PRIOR TO PLANTING. ANY PLANTS NOT MEETING SPECIFICATIONS MAY BE REJECTED.
C. ALL PLANT MATERIAL SHALL AT LEAST MEET MINIMUM REQUIREMENTS SHOWN IN THE " AMERICAN STANDARDS FOR NURSERY STOCK" (ANSI Z60.1 LATEST EDITION. ALL PLANTS ARE TO BE INSPECTED
TO PLANTING.
B. CONTRACTOR SHALL FLAG ALL PLANT MATERIAL LOCATIONS IN THE FIELD FOR OWNER OR OWNER'S REPRESENTATIVE APPROVAL PRIOR TO PLANTING. CONTRACTOR TO PROVIDE 3 DAYS NOTICE PRIOR
SERVICES DURING CONSTRUCTION DUE TO THE CONTRACTOR'S CARELESSNESS SHALL BE CORRECTED AT THE CONTRACTOR'S EXPENSE.
A. NOTIFY UTILITY COMPANIES PRIOR TO BEGINNING WORK. CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXISTENCE OF EXACT LOCATION AN DEPTH OF ALL UTILITIES. ANY DAMAGE TO UTILITIES AND
50' BUILDING SETBACK
50' BUILDING SETBACK FUTURE ROAD60' BUILDING SETBACKPARKING STALLS
35 PROPOSED
Easement
30' Sanitary Sewer
PARKING STALLS
31 PROPOSED
Easement
50' Sanitary Sewer
Existing
SHRUBS.
RESIDENTIALLY ZONED PROPERTIES BY FENCE AND/OR EVERGREEN
--SCREENED FROM THE ADJACENT STREET AND FROM ADJACENT
MECHANICAL EQUIPMENT:
8' HT.
8' HT.
5 8' HT.40' HT.B&B
4 6' HT.45' HT.B&B
QR Quercus robur 'Crimschmidt'
PG Picea glauca WHITE SPRUCE
4. CONTRACTOR SHALL SOD ALL AREAS DISTURBED BY CONSTRUCTION UNLESS OTHERWISE NOTED ON PLANS.
3. ALL PLANTING BEDS TO RECIEVE 4 INCH VERTICAL CUT EDGE ADJACENT TO LAWN AREAS UNLESS OTHERWISE DIRECTED BY OWNER.
MULCH TO OWNER'S REPRESENTATIVE FOR REVIEW AND APPROVAL.
2. PROVIDE 2 INCH RIVER ROCK MULCH PLACED TO A DEPTH OF 4 INCHES WITH WEED BARRIER FABRIC UNDERLAYMENT IN ALL MASS PLANTING BED AREAS. PROVIDE SAMPLE OF THE ROCK
SAMPLE OF THE MULCH FOR OWNERS REPRESENTATIVE FOR REVIEW AND APPROVAL.
1. PROVIDE 3- INCH DEPTH SHREDDED HARDWOOD MULCH AROUND ALL INDIVIDUAL DECIDUOUS TREES IN LAWN AREAS. MULCH SHALL BE A MINIMUM 3 FOOT RADIUS AROUND TREES. PROVIDE A
SHRUBS REQ'D (12 PROVIDED)
--SHRUBS REQ'D: 11,325 / 1,000 SF = 11.3
REQ'D (12 PROVIDED)
--TREES REQ'D: 11,325 / 1,000 SF = 11.3 TREES
1 SHRUB PER 1,000 SF OF REQ'D OPEN SPACE
& 25% EVERGREEN)
(50% OF TOTAL TREES MUST BE OVERSTORY
1 TREE PER 1,000 SF OF REQ'D OPEN SPACE
OPEN SPACE CALCULATIONS:
--OPEN SPACE PROVIDED: 22,401 SF (40.0%)
--56,625 X .20 = 11,325 SF REQ'D
MIN. 20% OPEN SPACE REQ'D
PARKING AND DRIVE AREA: 34,425 SF
BUILDING AREA: 10,399 SF
TOTAL LOT AREA: 56,625 SF (1.30 AC)
DISTRICT
ZONE: C1-B - LARGE-SCALE COMMERCIAL
6-HH
3-CA
6-JC
2-GD
2-PG
1-GD
1-MS
1-MS
2-PG
2-GD
6-CB
3-QR
2-GT 1-GT
1-QR
6-PO
6-CB
2-CA3-HH 3-CA2-CA
3-HH
3-HH
1-MS
3-CA
7-HH
3-CA5-HH
MS 5 6' HT.20' HT.B&B
'STREET KEEPER' HONEYLOCUST
'CRIMSON SPIRE' COLUMNAR OAK
'SUMMER WINE' NINEBARK& GRASSSHRUB, PERENNIAL, 4
4
4
4
4
4
2
2 2
2
2
2
4
4
4
4
4
4
44
4
2
2
2.0' TYP.
2.0' TYP.
4
4
--NO BUFFER REQUIRED.
WEST PROPERTY LINE: (C1-B)
--NO BUFFER REQUIRED.
SOUTH PROPERTY LINE: (C1-B)
--BUFFER REQUIRED (18 SHRUBS PROVIDED).
EAST PROPERTY LINE: (C1-B)
--NO BUFFER REQUIRED.
NORTH PROPERTY LINE: (C1-B)
BUFFER REQUIREMENTS:
3-PO
3-PO
--SOUTH FRONTAGE ROAD: (24) SHRUBS PROVIDED
C. HEADLIGHT SCREENING REQUIRED
--50% TOTAL ISLAND TREES TO BE OVERSTORY
--11 TREES REQ'D (11 PROVIDED)
--1 TREE PER EACH 9'X18' ISLAND & TERMINAL ISLAND
B. INTERIOR PARKING LOT REQ'D:
P.U. REQUIRED
--SETBACK REQUIREMENTS COUNT TOWARDS TOTAL OPEN SPACE
PROVIDED)
--SOUTH FRONTAGE RD.: 216 LF / 40 LF = 5.4 TREES REQ'D (6
PROVIDED ALONG NORTH BOUNDARY)
--EAST FUTURE RD.: 200 LF / 40 LF = 5 TREES REQ'D (5
--1 OVERSTORY TREE / 40 LF FRONTAGE
A. SETBACK - PARKING LOT TO R.O.W. REQ'D:
OFF STREET PARKING REQUIREMENTS:
1-QR
6-SB
6-CA
9-SB
4-CA
SB 15 'TOR BIRCHLEAF' SPIREA 24" Ht.3-4' HT.CONT. (3' O.C.)Spiraea betulifolia 'Tor'
1-MS
NE VENTURE DRIVE (PRIVATE)
Malus 'Spring Snow''SPRING SNOW' CRABAPPLE