HomeMy WebLinkAbout2017-02-13-D01 MidAmerican Energy Relocation Agr_Revision 2 AGENDA ITEM:
CITY OF WAUKEE, IOWA
CITY COUNCIL MEETING COMMUNICATION
MEETING DATE: February 13, 2017
AGENDA ITEM: Consideration of approval of a resolution approving Relocation and
Reimbursement Agreement (Revision No. 2) with MidAmerican Energy
Company [Alice’s Road between University Avenue and NE Horizon Drive,
Utility Relocation]
FORMAT: Resolution
SYNOPSIS INCLUDING PRO & CON: This Relocation and Reimbursement Agreement with Mid
American has the following additional provision changes:
Four additional poles are required to be relocated north of Hickman Road for and additional
cost of $75,000
The agreement execution due date changes to February 14, 2017
Easement acquisition due date changed to March 31, 2017
Right-of-way staking changed to April 7, 2017 to allow for the easements to be recorded.
FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS:
COMMISSION/BOARD/COMMITTEE COMMENT:
STAFF REVIEW AND COMMENT:
RECOMMENDATION: Approve the resolution.
ATTACHMENTS: I. Proposed Resolution
PREPARED BY: Beth Richardson
REVIEWED BY: John Gibson
PUBLIC NOTICE INFORMATION –
NAME OF PUBLICATION:
DATE OF PUBLICATION:
THE CITY OF WAUKEE, IOWA
RESOLUTION 17-
APPROVING RELOCATION AND REIMBURSEMENT AGREEMENT, REVISION
NO. 2, BY AND BETWEEN THE CITY OF WAUKEE, IOWA, AND MIDAMERICAN
ENERGY COMPANY [ALICE’S ROAD BETWEEN UNIVERSITY AVENUE AND NE
HORIZON DRIVE, UTILITY RELOCATION]
IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA
WHEREAS, the City of Waukee, Iowa is a duly organized municipality within Dallas County;
AND,
WHEREAS, as part of the Alice’s Road Corridor Project, University Avenue to NE Horizon
Drive, MidAmerican Energy Company will relocate structures and related facilities associated
with an electrical line currently located on private easements along the west side of Alice’s
Road; AND,
WHEREAS, on October 17, 2016, the Waukee City Council approved a Relocation and
Reimbursement Agreement between the City of Waukee and MidAmerican Energy related to the
utility relocation (Resolution #16-462); AND,
WHEREAS, on November 21, 2016, the Waukee City Council approved a revised Relocation
and Reimbursement Agreement related to said project (Resolution #16-505); AND,
WHEREAS, MidAmerican Energy Company has provided a revised agreement related to
additional pole relocation and construction timeline changes, of which City staff recommends
approval;
NOW THEREFORE BE IT RESOLVED by the City of Waukee City Council in session this
13th day of February, 2017, that the Relocation and Reimbursement Agreement, Revision No. 2,
by and between the City of Waukee, Iowa, and MidAmerican Energy Company, attached hereto
as Exhibit A and made part of this resolution, is hereby approved.
____________________________
William F. Peard, Mayor
Attest:
___________________________________
Rebecca D. Schuett, City Clerk
ROLL CALL VOTE AYE NAY ABSENT ABSTAIN
Anna Bergman
R. Charles Bottenberg
Brian Harrison
Shelly Hughes
Larry R. Lyon
RELOCATION AND REIMBURSEMENT AGREEMENT (revised)
IT IS AGREED this ____ day of _____________, 2017, by and between the City of
Waukee, Iowa ("City") and MidAmerican Energy Company ("MidAmerican") as follows:
Recitals
A WHEREAS, as part of City’s planned reconstruction of Alice’s Road between University
Avenue and NE Horizon Drive, City desires that MidAmerican relocate structures and
related facilities of a MidAmerican owned and operated 161,000-volt electric line (known
collectively as “Electric Facilities”), which is presently located on private easements and
as generally shown on the attached Exhibit A, which Electric Facilities are an integral
part of MidAmerican's electric system providing electric service to Waukee, Iowa and
elsewhere;
B. WHEREAS, MidAmerican is willing to relocate the Electric Facilities as generally
shown on the attached Exhibit A in return for the compensation set forth in this
Agreement;
C. WHEREAS, City is willing to secure and coordinate acquisition of new easements with
MidAmerican for the relocated Electric Facilities;
D. WHEREAS, City is willing to reimburse MidAmerican for its costs to relocate the
Electric Facilities;
E. THEREFORE, the parties agree as follows:
1. Services. Following execution of this Agreement, the Services to be provided by
MidAmerican shall consist of relocation of the Electric Facilities as generally
shown on the attached Exhibit A and removal of the existing structures and related
facilities. MidAmerican shall commence the Services after execution of this
Agreement. Construction is expected to be completed by June 16, 2017; however,
weather, Electric Facilities easement acquisition, communication facilities
relocation by others, and unanticipated other work as necessary at the site to
achieve the objectives of this Agreement may affect the schedule. City
acknowledges that for MidAmerican to achieve this completion date, City must
execute this agreement by February 14, 2017 and provide new easements by March
31, 2017. If the dates are missed, commensurate extension of the completion date
may be required.
2. Site Conditions. MidAmerican assumes that any information furnished by City is
accurate and complete and is relying on such information. If MidAmerican
encounters, at the site, toxic substances, hazardous substances or hazardous wastes
(as such terms are defined in any Federal, state or local statute, regulation or
ordinance), which require special handling and/or disposal, and are not a part of the
services contracted for, MidAmerican shall immediately suspend further work in
the area of the materials and notify City of the condition. City shall immediately
take whatever precautions are legally required to eliminate such hazardous
conditions and properly handle and dispose of such substances or wastes so that the
Services may safely proceed. If site conditions cause an increase in MidAmerican's
cost of, or the time required for, performance of any part of the Services under a
Scope of Work, an equitable adjustment shall be made to the compensation paid
MidAmerican and the schedule. If during the course of the Services, MidAmerican
observes the existence of asbestos or asbestos-containing materials, MidAmerican
will immediately suspend further work in the area of the materials and notify City
of the condition, and City will determine the further course of action.
3. Compensation. All compensation for this work shall be based on MidAmerican's
actual costs with no additional mark up. The estimated cost for these Services is
One Million Twenty Five Thousand and 00/100 Dollars U.S. ($1,025,000.00).
When the Services are complete, MidAmerican shall provide City with an invoice
detailing the actual cost of the Services, which invoice shall be the amount of total
compensation due MidAmerican. Payment shall be due and payable upon
presentment of such invoice.
4. Prerequisite work by City. City shall identify and have staked the new location and
boundary of City’s right-of-way and identify and have staked the new location of
the Electric Facilities easement. This work shall be done by City on or about April
7, 2017.
City shall also allow ingress and egress over City’s property for MidAmerican to
perform these services.
City shall acquire new easements in the form of the attached Exhibit B.
5. Obsolete easements. MidAmerican shall release all easements that become
obsolete or unnecessary by the operation of this Agreement.
IN WITNESS WHEREOF, the City of Waukee, Iowa and MidAmerican Energy Company have
caused this Agreement to be executed by their duly authorized representatives to be effective on
the date and year first above written.
CITY OF WAUKEE, IOWA MIDAMERICAN ENERGY COMPANY
By: __________________________ By: __________________________
Name: Name: _________________________
Title: __________________________ Title: __________________________
PLS-CADD DRAWING8200840086008800900092009400960098001000010200104001060010800110001000105011001150120010001050110011501200 PI 8°39'11" PI 79°10'48" PI -22°43'21" PI -1°53'54" STR 101 STR#102 STR#102A STR#103 104 104A 105 105A 106 106A 107 107A 108 108A WV
WV
WV
TP
SIGN
SIGN
SIGN
SIGN
SB
SB
UB
SIGN
WV
SIGN
WV
WV SIGN
SIGN
SIGN
SIGN
UB
UB
TP
SB
SB
SB
SB
SB
SB SB
SB
SB
SB
WV
WV
WV
WV
GV
TP TP SIGN TP TP
TP
SIGN
TP SIGN WV WV WV
WV
SIGN
UB
SIGN SB SB SB SB
SIGN
SIGN SIGN SIGN SIGN SIGN SIGN SIGN SIGN SIGN
SIGN
SIGN
SIGN
WV
WV WV
WV
UB
UB
WV WV
BB BB
WV
WHU
WV
WHU
WV
LC
LC
LC
LC
LC
LC
LC
LC
60"
RCP
PREFERED STEEL
POLE #103 LOCATION
STR #102
LOCATION
13 KV
3' 161 KV W/ 13 KV UB 215' STRUCTURE
#102A LOCATION 215' CURVE DATA ~ =19° 50' 28.59" (LT) T =167.03 L =330.71 R =955.00 E =14.50 CURVE DATA ~ =9° 49' 43.23" (LT) T =103.18 L =205.85 E =4.43 POTSTA212+59.64 213+00 214+00 215+00 PCSTA215+73.45 216+00 217+00 218+00 219+00 PTSTA219+04.16 PI 217+40.48 220+00 221+00 222+00 223+00 224+00 225+00 226+00 227+00 228+00 229+00 230+00 231+00 232+00 233+00 234+00 235+00 236+00 PCSTA236+22.84 237+00 238+00 PRCSTA238+28.69 PI 237+26.02 239+00 PI 239+30.53 R =1200.00 STR 101 STR#102 STR#102A STR#103 104 104A 105 105A 106 106A 107 107A 108 108A 109 PI 8280.53 8°39'11" PI 8574.93 79°10'48" PI 9005.97 -22°43'21" PI 9311.91 -1°53'54" PI 11160.00 DATE REV APP DFTR HIGH VOLTAGE UNDERBUILD SHIELD DESIGN TENSION RULING SPAN DESIGN TENSION CONDUCTOR RULING SPAN DESIGN TENSION DESIGN TENSION CONDUCTOR NEUTRAL DESCRIPTION NO ICE NO ICE SAGGED AT (INIT) SAGGED AT(LOAD) RULING SPAN SAGGED AT(CREEP) RULING SPAN SAGGED AT(CREEP) 120 DEG F 120 DEG F NO WIND, MAX SAG NO WIND, INITIAL SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET 212 DEG F -20 DEG F VERTICAL SCALE IN FEET 0 50 HORIZONTAL SCALE IN FEET 0 100 200 50 DESIGN TENSION AT 2007 NESC HEAVY LOADING 0 DEG F, 4 PSF WIND, 0.5" ICE, 0.30 CONSTANT ALL LOCATE INFORMATION SHOWN IS APPROXIMATE, AND MUST BE FIELD VERIFIED BEFORE DIGGING. CALL THE APPROPRIATE LOCATING SERVICE BEFORE CONSTRUCTION. CONTACT HIGH VOLTAGE ENGINEERING WITH ANY CONSTRUCTION CONFLICTS BEFORE INSTALLATION OF FACILITIES. SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET KAD DAV 0 _____ OPGW - 12 336 LINNET 336 LINNET T2-556 AAC 10 20 30 40 88TH ST SUB TO ALICE`S RD SUB 161 KV LINE RELOCATION AT ALICE`S RD & UNIVERSITY AVE. WAUKEE, IA PROJECT: 32330 - FACILITY: D40 SHEET 1 OF 4 PRELIM 3/14/14 ISSUED FOR CONSTRUCTION KAD 4/24/14 EXHIBIT A EXISTING ROUTE
PLS-CADD DRAWING1100011200114001160011800120001220012400126001280013000132001340013600138001000105011001150120010001050110011501200 PI -0°09'36" PI -0°57'04" 109 109A 110 110A 111 111A 112 112A 113 113A 114 114A 115 UB
WV
WV WV TP WV WV (LT) CURVE DATA ~ =9° 42' 05.59" (RT) T =101.84 L =203.19 E =4.31 CURVE DATA
~ =10° 28' 31.13" (RT)
T =110.00
L =219.39
E =5.03
CURVE DATA ~ =10° 28' 31.13" (LT) T =110.00 L =219.39 E =5.03 238+00 PRCSTA238+28.69 239+00 240+00 PTSTA240+31.88 PI 239+30.53 241+00 242+00 243+00 244+00 245+00 246+00 247+00 248+00 249+00 250+00 251+00 252+00 253+00 254+00 PCSTA254+96.15 255+00 256+00 257+00 PRCSTA257+15.54 PI 256+06.15 258+00 259+00 PTSTA259+34.93 PI 258+25.54 260+00 261+00 262+00 263+00 264+00 265+00 POTSTA265+78.45 R =1200.00
R =1200.00 R =1200.00 109 109A 110 110A 111 111A 112 112A 113 113A 114 114A 115 115A PI 11160.00 -0°09'36" PI 13688.77 -0°57'04" DATE REV APP DFTR HIGH VOLTAGE UNDERBUILD SHIELD DESIGN TENSION RULING SPAN DESIGN TENSION CONDUCTOR RULING SPAN DESIGN TENSION DESIGN TENSION CONDUCTOR NEUTRAL DESCRIPTION NO ICE NO ICE SAGGED AT (INIT) SAGGED AT(LOAD) RULING SPAN SAGGED AT(CREEP) RULING SPAN SAGGED AT(CREEP) 120 DEG F 120 DEG F NO WIND, MAX SAG NO WIND, INITIAL SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET 212 DEG F -20 DEG F VERTICAL SCALE IN FEET 0 50 HORIZONTAL SCALE IN FEET 0 100 200 50 DESIGN TENSION AT 2007 NESC HEAVY LOADING 0 DEG F, 4 PSF WIND, 0.5" ICE, 0.30 CONSTANT ALL LOCATE INFORMATION SHOWN IS APPROXIMATE, AND MUST BE FIELD VERIFIED BEFORE DIGGING. CALL THE APPROPRIATE LOCATING SERVICE BEFORE CONSTRUCTION. CONTACT HIGH VOLTAGE ENGINEERING WITH ANY CONSTRUCTION CONFLICTS BEFORE INSTALLATION OF FACILITIES. SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET KAD DAV 0 _____ OPGW - 12 336 LINNET 336 LINNET T2-556 AAC 10 20 30 40 88TH ST SUB TO ALICE`S RD SUB 161 KV LINE RELOCATION AT ALICE`S RD & UNIVERSITY AVE. WAUKEE, IA PROJECT: 32330 - FACILITY: D40 SHEET 2 OF 4 ISSUED FOR CONSTRUCTION KAD 4/24/14 EXHIBIT A EXISTING ROUTE
PLS-CADD DRAWING1380014000142001440014600148001500015200154001560015800160001620016400166001000105011001150120010001050110011501200 PI 1°21'07" PI -0°50'59" PI -98°33'48" PI -92°08'00" 115A 116 116A 117 117A 118 118A 118B WV WV TP
WV WV 262+00 263+00 264+00 265+00 POTSTA265+78.45 114A 115 115A 116 116A 117 117A 118 118A 118B 119 PI 13688.77 -0°57'04" PI 14098.84 1°21'07" PI 15776.37 -0°50'59" PI 16152.15 -98°33'48" 9 1 0 "
P I 1 7 5 7 2 .8 5
0 °0 0 '0 0 " DATE REV APP DFTR HIGH VOLTAGE UNDERBUILD SHIELD DESIGN TENSION RULING SPAN DESIGN TENSION CONDUCTOR RULING SPAN DESIGN TENSION DESIGN TENSION CONDUCTOR NEUTRAL DESCRIPTION NO ICE NO ICE SAGGED AT (INIT) SAGGED AT(LOAD) RULING SPAN SAGGED AT(CREEP) RULING SPAN SAGGED AT(CREEP) 120 DEG F 120 DEG F NO WIND, MAX SAG NO WIND, INITIAL SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET 212 DEG F -20 DEG F VERTICAL SCALE IN FEET 0 50 HORIZONTAL SCALE IN FEET 0 100 200 50 DESIGN TENSION AT 2007 NESC HEAVY LOADING 0 DEG F, 4 PSF WIND, 0.5" ICE, 0.30 CONSTANT ALL LOCATE INFORMATION SHOWN IS APPROXIMATE, AND MUST BE FIELD VERIFIED BEFORE DIGGING. CALL THE APPROPRIATE LOCATING SERVICE BEFORE CONSTRUCTION. CONTACT HIGH VOLTAGE ENGINEERING WITH ANY CONSTRUCTION CONFLICTS BEFORE INSTALLATION OF FACILITIES. SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET KAD DAV 0 _____ OPGW - 12 336 LINNET 336 LINNET T2-556 AAC 10 20 30 40 88TH ST SUB TO ALICE`S RD SUB 161 KV LINE RELOCATION AT ALICE`S RD & UNIVERSITY AVE. WAUKEE, IA PROJECT: 32330 - FACILITY: D40 SHEET 3 OF 4 ISSUED FOR CONSTRUCTION KAD 4/24/14 EXHIBIT A EXISTING ROUTE
PLS-CADD DRAWING8200840086008800900092009400960098001000010200104001060010800110001000105011001150120010001050110011501200 PI 8°39'11" PI 79°10'48" PI -22°43'21" PI -1°54'11" PI -0°12'01" PI -17°29'27" PI 19°25'51" PI -3°01'22" STR 101 STR#102 STR#102A STR#103 104 104A 105 105A 106 106A 107 107A 107B 108 108A 8449 1048.45 SCR 1INGP
LC 9066 1043.88 LC 1/2IRWYC BENT
LC 9067 1042.58 LC 1INGP3169
LC 11496 1042.81 LC 5/8IR-BENT LC 110549 1046.92 LC 1INGP LC 110550 1045.41 LC 1INGP-12971 LC 110551 1048.29 LC 5/8IRWYC LC 110552 1048.92 LC 1/2IR15980 LC 110553 1047.14 LC 1/2IRWYC LC 111194 1047.63 LC 5/8IRWYC7844
LC 111195 1047.77 LC 5/8IRWYC7844
LC 111196 1048.67 LC 5/8IRWYC7844 LC 111197 1048.42 LC 5/8IRWYC7844
10' PUE
10' PUE
10' X 30' QWEST EASEMENT
10' PUE
20' OVERLAND FLOWAGE EASEMENT
30' OVERLAND FLOWAGE EASEMENT
100'X30' STORM SEWER AND OVERLAND FLOWAGE EASEME 25' SANITARY EASEMENT 80'X30' STORM SEW & OVERLAND FLOWA 30' OVERLAND FLOWAGE EASEMENT
EXISTING 10' PUE
EXISTING 70'X10'
SIDEWALK EASEMENT
EXISTING 93' TRANSMISSION EASEMENT EXISTING 30' WATER MAIN AND RECREATIONAL TRAIL EASEMENT
EXISTING
TRANSMISSION EASEMENT
EXISTING 30'
INGRESS-EGRESS
EASEMENT
EXISTING 20'
SANITARY SEWER
EASEMENT
(PRIVATE)
EXISTING 10' PUE
10' MONUMENT SIGN
EASEMENT
10' PUE
15'X50'
PRIVATE INGRESS/EGRESS
EASEMENT
30'X50' PRIVATE INGRESS/EGRESS EASEMENT GILCREST/JEWETT LUMBER COMPANY DJN, LLC TTM ALICE, LLC DLE FOUR WAY, LLC CENTENNIAL DEVELOPMENT LC CENTENNIAL DEVELOPMENT LC CENTENNIAL DEVELOPMENT LC CENTENNIAL DEVELOPMENT LC AZTEC PROPERTIES, LLC 1 2 3 4 6 12 13 14 15 16 17 18 WILLIAMS POINT COMMERCIAL II, LC WILLIAMS POINT COMMERCIAL I, LC 28 27 RAILROAD DALLAS COUNTY CONSERVATION GREATER IOWA CREDIT UNION CENTENNIAL
DEVELOPMENT LC
15
DJN, LLC
2
TTM ALICE, LLC
3
AZTEC PROPERTIES, LLC 6 CENTENNIAL DEVELOPMENT LC 17 DLE FOUR WAY, LLC 4 CENTENNIAL DEVELOPMENT LC 16 DLE FOUR WAY, LLC 4
GILCREST/JEWETT
LUMBER COMPANY
1
13
WILLIAMS POINT
COMMERCIAL I, LC GILCREST/JEWETT
LUMBER COMPANY
1
12
GREATER IOWA CREDIT UNION
CENTENNIAL DEVELOPMENT LC 18 AZTEC PROPERTIES, LLC 6 CENTENNIAL DEVELOPMENT LC 16
CENTENNIAL
DEVELOPMENT LC
15
29
TSG PROPERTIES WAUKEE LLC TSG PROPERTIES WAUKEE LLC 29 AZTEC PROPERTIES, LLC 30 AZTEC PROPERTIES, LLC 30 HEDDEN ENTERPRISES, LC 31 HEDDEN ENTERPRISES, LC 31 10' PUE 10' PUE EXISTING 20' WATER MAIN EASEMENT EXISTING 20' WATER MAIN EASEMENT 20' X 20' QWEST EASEMENT
LC 111485 1046.88 LC IRYCAP16747
LC 111486 1050.42 LC IRYCAP16747
111489 1047.02 CP IROCAPCONTROL
LC 111490 1045.30 LC IRYCAP12971
503 1048.38 SCR 3/4 IP BENT
504 1046.91 SCR X IN CONC
LC 511 1047.61 LC 1 GP WYC 12972
LC 518 1043.96 LC 1/2 IR
LC 523 1037.21 LC 3/4 GP WYC 12972
LC 524 1043.22 LC 3/4 GP WYC 12972
LC 525 1044.90 LC 3/4 GP WYC 12972
LC 526 1047.52 LC 3/4 GP WYC 12972
LC 111483 1046.95 LC 5/8IR7844 STR 101 STR#102 STR#102A STR#103 104 104A 105 105A 106 106A 107 107A 107B 108 108A PI 8280.53 8°39'11" PI 8574.93 79°10'48" PI 9005.97 -22°43'21" PI 9311.91 -1°54'11" PI 10420.56 -0°12'01" PI 10605.74 -17°29'27" PI 10700.75 19°25'51" PI 10811.82 -3°01'22" DATE REV APP DFTR HIGH VOLTAGE UNDERBUILD SHIELD DESIGN TENSION RULING SPAN DESIGN TENSION CONDUCTOR RULING SPAN DESIGN TENSION DESIGN TENSION CONDUCTOR NEUTRAL DESCRIPTION NO ICE NO ICE SAGGED AT (INIT) SAGGED AT(LOAD) RULING SPAN SAGGED AT(CREEP) RULING SPAN SAGGED AT(CREEP) 120 DEG F 120 DEG F NO WIND, MAX SAG NO WIND, INITIAL SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET 212 DEG F -20 DEG F VERTICAL SCALE IN FEET 0 50 HORIZONTAL SCALE IN FEET 0 100 200 50 DESIGN TENSION AT 2007 NESC HEAVY LOADING 0 DEG F, 4 PSF WIND, 0.5" ICE, 0.30 CONSTANT ALL LOCATE INFORMATION SHOWN IS APPROXIMATE, AND MUST BE FIELD VERIFIED BEFORE DIGGING. CALL THE APPROPRIATE LOCATING SERVICE BEFORE CONSTRUCTION. CONTACT HIGH VOLTAGE ENGINEERING WITH ANY CONSTRUCTION CONFLICTS BEFORE INSTALLATION OF FACILITIES. SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET KAD DAV 0 _____ OPGW - 12 336 LINNET 336 LINNET T2-556 AAC 10 20 30 40 88TH ST SUB TO ALICE`S RD SUB 161 KV LINE RELOCATION AT ALICE`S RD & UNIVERSITY AVE. WAUKEE, IA PROJECT: 32330 - FACILITY: D40 SHEET 1 OF 5 PRELIM 3/14/14 ISSUED FOR CONSTRUCTION KAD 4/24/14 SE ALICE`S RD 1 11/18/16 NLJ PROJECT T90LP - STRUCTURE RELOCATION
PLS-CADD DRAWING1100011200114001160011800120001220012400126001280013000132001340013600138001000105011001150120010001050110011501200 PI 0°06'44" PI 1°07'18" PI 0°00'20" PI 1°15'17" PI -1°19'29" PI -1°26'59" 109 109A 110 111 111A 112 113 113A 114 115 115A LC 110549 1046.92 LC 1INGP
LC 110550 1045.41 LC 1INGP-12971
LC 110554 1036.88 LC DOT DISK LC 110555 1036.59 LC DOT DISK
LC 110556 1045.04 LC 1/2IRWYC3321
LC 110557 1043.99 LC 1/2GPWYC14775
LC 110558 1044.35 LC 1/2IRBENT
LC 110559 1046.25 LC 1/2IRWYC4640
LC 110560 1045.45 LC 1/2IRWYC
LC 110561 1045.19 LC 1/2IRBENT
LC 110562 1045.70 LC 1/2IRBENT
LC 111007 1030.43 LC 5/8IR WYC13148 LC 111008 1031.03 LC 1/2IR WYC11804 LC 111184 1032.76 LC 1/2IRINCONC
11118 1045.6 LC 5/8IRWYC9517
LC 111189 1044.59 LC 1/2GPWYC14775
LC 111190 1043.93 LC 1/2GPWYC14775
LC 111191 1044.39 LC 1/2IRWYC3321
25' SANITARY EASEMENT
30' OVERLAND FLOWAGE EASEMENT
30' BIKE
10' PUE
25' ELECTRIC TRANSMISSION EASEMENT
EXISTING 93'
TRANSMISSION EASEMENT
EXISTING 30'
WATER MAIN AND
RECREATIONAL TRAIL EASEMENT
10' PUE
7.5' PUE
15' PUE
15' PUE NIAL ENT LC B D L PROPERTIES, INC ETZEL, ROBERT F LIVING TRUST 7 ETZEL, ROBERT F TRUSTEE ETZEL, ROBERT F LIVING TRUST 7 ETZEL, ROBERT F TRUSTEE EAAI HOLDINGS, LLC B D L PROPERTIES, INC B D L PROPERTIES, INC JRC INVESTMENTS, LLC PENTA PARTNERS LLC ETZEL, ROBERT F LIVING TRUST 7 ETZEL, ROBERT F TRUSTEE ATLANTIC BOTTLING COMPANY ATLANTIC BOTTLING COMPANY HURD WAUKEE LLC HURD WAUKEE LLC 7 7 7 10 11 8 19 20 21 22 23 24 25 26 ETZEL, ROBERT F LIVING TRUST 7 ETZEL, ROBERT F TRUSTEE
7
CENTENNIAL
DEVELOPMENT LC
18
B D L
PROPERTIES, INC
19
AZTEC PROPERTIES, LLC
6
30
20' X 45' QWEST EASEMENT
LC 111490 1045.30 LC IRYCAP12971
DNF 5055 1029.72 SCR SECTION CORNER
504 1046.91 SCR X IN CONC
LC 111477 1043.99 LC 1/2IRBENT
LC 111478 1045.53 LC 1INGP14775
LC 111479 1044.67 LC LOT CORNER
LC 624 1037.38 LC 5/8-18381 LC 625 1037.78 LC 5/8-18381 LC 626 1041.90 LC 5/8-18381 LC 627 1043.68 LC 5/8-18381 109 109A 110 111 111A 112 113 113A 114 115 115A 115A - EAST 115A - WEST PI 11176.35 0°06'44" PI 11455.83 1°07'18" PI 11734.96 0°00'20" PI 12849.34 1°15'17" PI 13130.71 -1°19'29" PI 13693.24 -1°26'59" PI 17414.82 0°00'00" DATE REV APP DFTR HIGH VOLTAGE UNDERBUILD SHIELD DESIGN TENSION RULING SPAN DESIGN TENSION CONDUCTOR RULING SPAN DESIGN TENSION DESIGN TENSION CONDUCTOR NEUTRAL DESCRIPTION NO ICE NO ICE SAGGED AT (INIT) SAGGED AT(LOAD) RULING SPAN SAGGED AT(CREEP) RULING SPAN SAGGED AT(CREEP) 120 DEG F 120 DEG F NO WIND, MAX SAG NO WIND, INITIAL SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET 212 DEG F -20 DEG F VERTICAL SCALE IN FEET 0 50 HORIZONTAL SCALE IN FEET 0 100 200 50 DESIGN TENSION AT 2007 NESC HEAVY LOADING 0 DEG F, 4 PSF WIND, 0.5" ICE, 0.30 CONSTANT ALL LOCATE INFORMATION SHOWN IS APPROXIMATE, AND MUST BE FIELD VERIFIED BEFORE DIGGING. CALL THE APPROPRIATE LOCATING SERVICE BEFORE CONSTRUCTION. CONTACT HIGH VOLTAGE ENGINEERING WITH ANY CONSTRUCTION CONFLICTS BEFORE INSTALLATION OF FACILITIES. SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET KAD DAV 0 _____ OPGW - 12 336 LINNET 336 LINNET T2-556 AAC 10 20 30 40 88TH ST SUB TO ALICE`S RD SUB 161 KV LINE RELOCATION AT ALICE`S RD & UNIVERSITY AVE. WAUKEE, IA PROJECT: 32330 - FACILITY: D40 SHEET 2 OF 5 ISSUED FOR CONSTRUCTION KAD 4/24/14 SE ALICE`S RD 1 11/18/16 NLJ PROJECT T90LP - STRUCTURE RELOCATION
PLS-CADD DRAWING1380014000142001440014600148001500015200154001560015800160001620016400166001000105011001150120010001050110011501200 PI 1°42'41" PI 2°06'20" PI 0°46'39" PI -1°43'39" PI 3°29'12" PI -3°17'42" PI -0°31'14" PI -0°31'23" PI -0°17'08" PI -0°46'14" PI -98°33'48" PI 0°00'00" PI 0°00'00" 115A 116 116A 117 117A 117A(T) 117B 117C 118 118A 119 119A 120 8076 1019.33 SCR X
LC 110564 1029.19 LC GPBENT
LC 110565 1022.95 LC 1/2IRWYC LC 110566 1022.99 LC 1/2IRWYC
LC 111005 1029.22 LC 1/2IR WYC3321
LC 111006 1022.54 LC BENT
LC 111007 1030.43 LC 5/8IR WYC13148 LC 111008 1031.03 LC 1/2IR WYC11804
LC 111184 1032.76 LC 1/2IRINCONC LC 111185 1031.99 LC 1/2IRINCONC
LC 30001 1028.22 LC IRYCAP
LC 30008 1028.89 LC CUTX
CALC AND SEARCH
DNF
5055 1029.72 SCR SECTION CORNER
602 1020.99 SCR X
LC 605 1015.26 LC 5/8IR
LC 606 1009.96 LC 5/8IR7844
LC 607 1010.74 LC 5/8IR7844
LC 608 1015.06 LC 5/8IR7844
612 1020.99 SCR X
LC 615 1015.26 LC 5/8IR
LC 616 1009.96 LC 5/8IR-7844
LC 617 1010.74 LC 5/8IR-7844
LC 618 1015.06 LC 5/8IR-7844
LC 743 1028.34 LC 5/8IR
FOUND
6280 42 UNIVERSITY OF IOWA COMMUNITY CREDIT UNION 43 HY-VEE 44 CONTINENTAL 296 FUND LLC 45 WRIGHT TREE SERVICE, INC. 46 WRIGHT TREE SERVICE, INC. EXISTING 93'
TRANSMISSION EASEMENT 115A 116 116A 117 117A 117A(T) 117B 117C 118 118A 119 119A 120 115A - EAST 115A - WEST 117C - EAST PI 13934.68 1°42'41" PI 14103.27 2°06'20" PI 14248.44 0°46'39" PI 14391.28 -1°43'39" PI 14679.59 3°29'12" PI 14757.44 -3°17'42" PI 14850.98 -0°31'14" PI 14957.29 -0°31'23" PI 15362.63 -0°17'08" PI 15781.84 -0°46'14" PI 16157.62 -98°33'48" PI 16392.38 °00'00" PI 16692.38 0°00'00" PI 17414.82 0°00'00" PI 17938.12 0°00'00" PI 18350.36 0°00'00" DATE REV APP DFTR HIGH VOLTAGE UNDERBUILD SHIELD DESIGN TENSION RULING SPAN DESIGN TENSION CONDUCTOR RULING SPAN DESIGN TENSION DESIGN TENSION CONDUCTOR NEUTRAL DESCRIPTION NO ICE NO ICE SAGGED AT (INIT) SAGGED AT(LOAD) RULING SPAN SAGGED AT(CREEP) RULING SPAN SAGGED AT(CREEP) 120 DEG F 120 DEG F NO WIND, MAX SAG NO WIND, INITIAL SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET 212 DEG F -20 DEG F VERTICAL SCALE IN FEET 0 50 HORIZONTAL SCALE IN FEET 0 100 200 50 DESIGN TENSION AT 2007 NESC HEAVY LOADING 0 DEG F, 4 PSF WIND, 0.5" ICE, 0.30 CONSTANT ALL LOCATE INFORMATION SHOWN IS APPROXIMATE, AND MUST BE FIELD VERIFIED BEFORE DIGGING. CALL THE APPROPRIATE LOCATING SERVICE BEFORE CONSTRUCTION. CONTACT HIGH VOLTAGE ENGINEERING WITH ANY CONSTRUCTION CONFLICTS BEFORE INSTALLATION OF FACILITIES. SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET SEE TENSION SHEET KAD DAV 0 _____ OPGW - 12 336 LINNET 336 LINNET T2-556 AAC 10 20 30 40 88TH ST SUB TO ALICE`S RD SUB 161 KV LINE RELOCATION AT ALICE`S RD & UNIVERSITY AVE. WAUKEE, IA PROJECT: 32330 - FACILITY: D40 SHEET 3 OF 5 ISSUED FOR CONSTRUCTION KAD 4/24/14 NE ALICE`S RD 1 11/18/16 NLJ PROJECT T90LP - STRUCTURE RELOCATION
Prepared by and return to: Jason Romey (515) 242-4070
MIDAMERICAN ENERGY ATTN: RIGHT-OF-WAY SERVICES PO BOX 657 DES MOINES, IA 50306-0657
MIDAMERICAN ENERGY COMPANY
ELECTRIC TRANSMISSION LINE EASEMENT
State of
Folder No. County of
Work Req. No. Section
Project No. Township North
Range West of the 5th P.M.
1. For and in consideration of the sum of One and no/100 Dollar ($1.00), and other valuable
consideration, in hand paid by MIDAMERICAN ENERGY COMPANY, an Iowa corporation, receipt of
which is hereby acknowledged, the undersigned owner(s) , its successors and assigns, and the
undersigned tenant(s) and parties of interest (collectively the “Grantor”), does hereby grant to
MIDAMERICAN ENERGY COMPANY, its successors and assigns (“Grantee”), a perpetual, non-
exclusive easement to construct, reconstruct, operate, maintain, replace or remove electric supply line(s)
for the transmission and distribution of electric energy and for communication and electrical controls,
including other reasonably necessary poles, towers, wires, guys, guy stubs, anchors and other
reasonably necessary equipment incident thereto (collectively “Facilities”) upon, over, along, and across
certain property described below, together with the right to survey the property and the right of ingress
and egress to and from the same and all the rights and privileges incident and necessary to the
enjoyment of this easement (“Easement Area”), including the right to trim, cut down and remove such
trees, brush, saplings and bushes as may interfere with the proper construction, maintenance, operation
or removal of said lines, upon, over, along and across the property described below.
DESCRIPTION OF PROPERTY CONTAINING EASEMENT AREA:
DESCRIPTION OF EASEMENT AREA:
INSERT DESCRIPTION OF EXACT LOCATION OF EASEMENT
2. Subject to the rights of the Grantee granted herein, Grantor shall have the right to
cultivate, use and occupy the land. No brush or other inflammable materials shall be deposited,
or accumulated or burned within the easement area.
3. Grantor agrees that it will not construct or place any permanent or temporary buildings,
structures, fences, trees, plants, or other objects on the Easement Area described herein, or
make any changes in ground elevation without written permission from Grantee indicating that
said construction or ground elevation changes will not result in inadequate or excessive ground
cover, or otherwise interfere with the Grantee’s rights to operate and maintain its Facilities, and
that no act shall be performed which violates the clearance requirements of the National Electrical
Safety Code and/or the rules of the state utility regulatory authority where the Facilities are
located.
4. In consideration of such grant, Grantee agrees that it will repair or pay for any damage
which may be caused to tile, crops, fences, or other property, real or personal, of the Grantor by
the construction, reconstruction, maintenance, operation, replacement or removal of the Facilities
(except for damage to property placed subsequent to the granting of this easement) that Grantee
determines interferes with the operation and maintenance of the Facilities and associated
equipment. The cutting, recutting, trimming and removal of trees, branches, saplings, brush or
other vegetation on or adjacent to the Easement Area is expected and not considered damage to
the Grantor.
5. Grantor certifies that it is not acting, directly or indirectly, for or on behalf of any person,
group, entity or nation named by any Executive Order or the United States Treasury Department
as a terrorist, “Specially Designated National and Blocked Person” or any other banned or
blocked person, entity, nation or transaction pursuant to any law, order, rule or regulation that is
enforced or administered by the Office of Foreign Assets Control; and are not engaged in this
transaction, directly or indirectly on behalf of, any such person, group, entity or nation. Grantor
hereby agrees to defend, indemnify and hold harmless Grantee from and against any and all
claims, damages, losses, risks, liabilities and expenses (including attorney’s fees and costs)
arising from or related to any breach of the foregoing certification.
6. Each of the provisions of this easement shall be enforceable independently of any other
provision of this easement and independent of any other claim or cause of action. In the event of
any matter or dispute arising out of or related to this easement, it is agreed between the parties
that the law of the jurisdiction and location where this easement is recorded (including statute of
limitation provisions) will govern the interpretation, validity and effect of this easement without
regard to the place of execution or place of performance thereof, or any conflicts or law
provisions. TO THE FULLEST EXTENT PERMITTED BY LAW, EACH OF THE PARTIES
HERETO WAIVES ANY RIGHT IT MAY HAVE TO A TRIAL BY JURY IN RESPECT OF
LITIGATION DIRECTLY OR INDIRECTLY ARISING OUT OF, UNDER OR IN CONNECTION
WITH THIS EASEMENT. EACH PARTY FURTHER WAIVES ANY RIGHT TO CONSOLIDATE
ANY ACTION IN WHICH A JURY TRIAL HAS BEEN WAIVED WITH ANY OTHER ACTION IN
WHICH A JURY TRIAL CANNOT BE OR HAS NOT BEEN WAIVED.
7. Grantor hereby relinquishes all rights of dower, homestead and distributive share in and
to the Easement Area and waives all rights of exemption as to any of the Easement Area.
Grantor understands that homestead property is in many cases protected from the claims of
creditors and exempt from judicial sale; and that by signing this easement, Grantor voluntarily
gives up any right to this protection for the Easement Area with respect to claims based upon this
easement.
8. Grantor warrants to Grantee that Grantor holds title to the Easement Area in fee simple
and Grantor has good and lawful authority to grant the rights provided in this easement.
(Acknowledgments on following page)
Dated this day of , 20____
INSERT COMPANY NAME IF A CORPORATION
ACKNOWLEDGMENT
STATE OF )
) ss
COUNTY OF )
This record was acknowledged before me on , 20___, by (NAME OF
PERSON) as (TITLE) of COMPANY NAME .
Signature of Notary
Public
ACKNOWLEDGMENT
STATE OF )
) ss
COUNTY OF )
This record was acknowledged before me on , 20___, by (NAME
OF PERSON(S) AND MARITAL STATUS).
Signature of Notary
Public
Consent of Party in Interest
The undersigned does hereby consent to the terms and conditions of the Electric
Transmission Line easement described herein.
By:
Its:
Printed or typed name and title
STATE OF )
) ss
COUNTY OF )
This record was acknowledged before me on , 20___, by (NAME OF
PERSON) as (TITLE) of COMPANY NAME .
Signature of Notary
Public