HomeMy WebLinkAbout2017-03-06-J02 Cove at Kettlestone Lot 3_SitePlan AGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: March 6, 2017 AGENDA ITEM: Consideration of approval of a resolution approving a site plan for Cove at Kettlestone Lot 3 [1200 SE University Avenue] FORMAT: Resolution SYNOPSIS INCLUDING PRO & CON: Waukee Investments I, LLC, requests approval of a site plan to allow the site improvements for the construction of a multi-tenant commercial building. The site plan identifies a 15,540 square feet multi-tenant commercial building to be constructed on a 2.09 acre lot located at the intersection of SE University Avenue and SE Bishop Drive. The site plan identifies the possibility of a future building on the lot to the west. These improvements will require site plan approvals as well. Access to the property will be provided via an access off of SE Bishop Drive. With future development of the lot to the west access to SE University Avenue will be provided. The applicant has provided elevations for proposed building on the site which meets the intent of the architectural guidelines within the Site Development and Building Standards Ordinance and the approved Planned Development Agreement for the property. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: Approval of a site plan for Cove at Kettlestone Lot 3 Senior Planner, Andy Kass, introduced a request for approval of a site plan for a multi-tenant commercial center by the applicant, Waukee Investments 1, LLC. Mr. Kass advised that the subject property is on the corner of SE Bishop and SE University Avenue. The proposed project includes the construction of a building 15,500 square feet in size with 9800 square feet designated for retail use and the eastern 5800 square feet is proposed for a restaurant use. A patio is identified on the eastern front of the building and the trash enclosure is indicated on the east side of the site south of the entrance. Mr. Kass advised that the site plan shows 127 parking spaces including 6 handicap spaces which is the minimum requirement for this site. 5 bicycle parking spaces are also identified on the site plan. Vehicular access will be off of SE Bishop Drive, a public street, to the East of the site with a temporary turn around provided for emergency vehicles. Mr. Kass Advised that the applicant owns lot 2 as well and intends to build a similar project at that location, which would then add a full access for both lots onto SE University Avenue at the time lot 2 is developed. Mr. Kass informed the commission that utilities are already stubbed to the property and both a grease interceptor and sprinkler system will be required. Storm water detention will be in the detention basin to the south of the lot before draining into the University Avenue Storm Sewer System. The site plan indicates a 26%open space which meets the minimum requirements and substantial screening has been provided for both the residential areas to the north and south of the project. Mr. Kass advised that the proposed building will be constructed of a variety of materials including brick, storefront glazing, and simulated wood panels (fiber cement). Galvanized steel mesh will be utilized on the east side of the building to screen mechanical equipment. The applicant has submitted a photometric plan and associated light fixture cut sheets, which meet the requirements outlined within the Planned Development Agreement and the Site Plan Ordinance. At this time staff is comfortable with the site plan and would recommend approval of the site plan subject to remaining staff comments. • Commissioner Fontenot questioned what the townhome builders and owners are using as access. Mr. Kass advised that currently there are accesses on SE Bishop Drive and SE Waco Place/ 98th Street. Mr. Kass also advised that the squares shown on the map show the location of the townhomes. • Commissioner Schmidt questioned what separated the current proposed building from the townhomes. Mr. Kass advised that there was no berm, a 10 foot set back and installed screening from headlights. The edge bordering University will be flat as well. This is because when University was widened the city did not have a right of way so to get the sidewalk and other amenities, the grading had to be decreased. A berm didn’t quite fit in the space allotted, however there is significant screening and the apartments across the street do have a substantial berm. • Commissioner Fontenot questioned how many tenants were planned. A representative of the applicant, Eric Cannon, advised that there were 5 units so 5 possible tenants. • Commissioner Hoifeldt questioned if there would be fencing on the patio. Mr. Cannon stated that it is on the elevations, black three foot high typical fencing. • Commissioner Stonebrook questioned what the white part of the elevation was. Director of development services, Brad Deets, advised that it was an architectural addition for variety and appearance, not structural. Commissioner Fontenot moved to approve the site plan for Cove at Kettlestone Lot 3, subject to remaining staff comments. The motion was seconded by Commissioner Schmidt. Ayes: Stonebrook, Fontenot, Hoifeldt, and Schmidt. Nays: None. Motion Carries. STAFF REVIEW AND COMMENT: At this time all staff comments have been addressed and staff recommends approval. RECOMMENDATION: Approve the resolution ATTACHMENTS: I. Proposed Resolution II. Staff Report III. Staff Comment Letter IV. Site Plan V. Elevations PREPARED BY: Andy Kass, Senior Planner REVIEWED BY: THE CITY OF WAUKEE, IOWA RESOLUTION 17- APPROVING THE SITE PLAN FOR COVE AT KETTLESTONE LOT 3 [1200 SE UNIVERSITY AVENUE] IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Site Plan for Cove at Kettlestone Lot 3, subject to remaining staff comments on February 28, 2017; AND, WHEREAS, the Site Plan for Cove at Kettlestone Lot 3 is in general conformance with §304 – Site and Building Development Standards Ordinance of the Waukee Municipal Code; AND, WHEREAS, the Site Plan for Cove at Kettlestone Lot 3 is in general conformance with §301.27(A) – Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND, NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 6th day of March, 2017 that the Site Plan for Cove at Kettlestone Lot 3 is approved. ____________________________ William F. Peard, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk ROLL CALL VOTE AYE NAY ABSENT ABSTAIN Anna Bergman R. Charles Bottenberg Brian Harrison Shelly Hughes Larry R. Lyon STAFF REPORT TO: Planning and Zoning Commission PREPARED BY: Andy Kass RE: Cove at Kettlestone Lot 3 – Site Plan DATE: February 28, 2017 GENERAL INFORMATION: Applicant: Waukee Investments I, LLC Requested Action Site Plan Approval Location and Size: Property is generally located south of SE University Avenue and west of SE Bishop Drive and containing approximately 2.09 acres. LAND USES AND ZONING: Location Existing Land Use Comprehensive Plan Current Zoning Property in Question Vacant Multi-Family Stacked High PD/C-1 North Winhall Apartments Neighborhood Residential PD/R-3 South Cove at Kettlestone Townhomes Multi-Family Stacked High PD/C-1 East Vacant Multi-Family Stacked Medium PD/C-1 West Vacant Multi-Family Stacked High PD/C-1 BACKGROUND: The subject property is located within the Cove at Kettlestone development that is located at the intersection of SE University Avenue and SE Waco Place. Initial phases of the development that have been approved are 131 townhomes and three 72 unit apartment buildings. This is the first commercial component of the overall development. March 2, 2017 2 of 3 ABOVE: Aerial of the site plan (outlined in RED) in relation to the surrounding properties. PROJECT DESCRIPTION: The proposed project includes the construction of a 15,540 square foot multi-tenant commercial building, associated parking, trash enclosure, and site utilities. The site plan identifies the building having a 9,800 square foot retail portion and 5,740 square foot restaurant portion of the building. An outdoor patio is also identified on the front of the building for the use of the restaurant. The trash enclosure is indicated on the east side of the site south of the entrance into the site. ACCESS AND PARKING: Access to the site will be provided on the east side of the site from SE Bishop Drive, a public street. The applicant also owns Lot 2 to the west with the intent of constructing a similar building on that site. When development of Lot 2 occurs a secondary access will be provided from SE University Avenue. The future access off of SE University Avenue will be an un-signalized full access. The current Capital Improvements Plan (CIP) identifies this location as a potential traffic signal project in the future, however, it does not identify a fiscal year for the project to be completed. A total of 127 parking spaces are required for this facility. The total amount of parking proposed is 127 spaces (including 6 handicap accessible stalls). The site plan also identifies 5 bicycle parking spaces. The bike rack is located along the northwest side of the building. March 2, 2017 3 of 3 As part of the improvements to the site a 5 foot sidewalk will be extended along SE University Avenue and a 10 foot trail will be extended along SE Bishop Drive on the east side of the site. Pedestrian connections into the site from these paths have been indicated on the site plan. UTILITIES: Storm water detention will be provided in the detention basin to the southwest of the site that is located within the Cove at Kettlestone Townhome development to the south. Water and sanitary services were stubbed into the lot as part of the initial plat improvements and the developer will be extending the services to the building and to Lot 2 to the west. OPEN SPACE AND LANDSCAPING: A minimum of 15% of the project area is required to be open space and the site plan indicates that 26.3% open space will be provided. Landscaping has been provided in compliance with the required planting requirements. ELEVATIONS: The proposed building will be constructed of a variety of materials including brick, storefront glazing, and simulated wood panels (fiber cement). Galvanized steel mesh will be utilized on the east side of the building to screen mechanical equipment. Per the adopted Planned Development Agreement for the property, 30% of the street facing façade at pedestrian level shall be fenestration, 32% fenestration is proposed. The proposed elevations meet the intent of both the Site Plan Ordinance as well as the Planned Development Agreement. Material samples will be available for review at the Planning & Zoning Commission meeting. MISCELLANEOUS: The applicant has submitted a photometric plan and associated light fixture cut sheets. The photometric plan and fixtures meet the requirements outlined within the Planned Development Agreement and the Site Plan Ordinance. STAFF RECOMMENDATION: At this time staff is comfortable with the site plan and would recommend approval of the site plan subject to remaining staff comments. CITY OF WAUKEE Andy Kass, AICP Senior Planner Development Services Department 230 W. Hickman Road Waukee, IA 50263 Phone: (515) 978-9533 Fax: (515) 987-1845 1st Review: January 24, 2017 2nd Review: February 7, 2017 3rd Review: February 28, 2017 4th Review: Snyder & Associates, Inc. Attn: Eric Cannon 2727 SW Snyder Blvd Ankeny, IA 50023 RE: Cove at Kettlestone Lot 3 – Site Plan Dear Mr. Cannon: Per your request, staff has reviewed the proposed site plan for the Cove at Kettlestone Lot 3. The property is located at west of SE Bishop Drive and south of SE University Avenue. Based upon our review, staff has the following comments related to the site plan: COVER SHEET & GENERAL COMMENTS 1. Provide a materials board prior to the Planning & Zoning Commission meeting. Engineers Response: 2. Provide a photometric plan with cut sheets for all proposed exterior fixtures. This project will not be forwarded for approvals until a photometric plan is provided for review. Engineers Response: 3. Verify that the Owner’s mailing address information is accurate. Engineers Response: 4. Please indicate the site address as 1200 SE University Avenue. Engineers Response: 5. Update the Vicinity Map to show SE Bishop Drive and the platted lots within the Cove at Kettlestone. Engineers Response: SHEET 2 | PROJECT INFORMATION 6. A note should be added to the plan set indicating that any proposed changes to the plan set shall be approved in writing by the City of Waukee Development Services Department. Engineers Response: Project Name Project Engineer/Manager Project Type City Contact Cove at Kettlestone Lot 3 Eric Cannon Site Plan Andy Kass 7. A note should be added to the plan set indicating that the contractor is responsible for any changes made during construction that have not been granted approval in writing by the City of Waukee Development Services Department. Engineers Response: 8. Provide a downspout connection detail, if applicable. Engineers Response: 9. Under General Note BB, change Public Works to Engineering Department. Change this in both instances. Engineers Response: SHEET 3 | DIMENSION PLAN 10. Note 7.B., “electrical” is spelled incorrectly. Engineers Response: 11. Please add a note to the dimension plan indicating that the City is not responsible for pavement replacement within the existing sanitary sewer easement if pavement needs to be removed for maintenance of the sanitary sewer. Engineers Response: 12. Indicate the sidewalk and trail widths. Engineers Response: 13. Staff questions if any bicycle parking will be provided. If so, please indicate locations. Include a bike rack detail in the plan set. Engineers Response: 14. Staff questions if a drive-thru window is proposed on the west end of the building. If so, indicate location and any associated menu board locations. Per the Arterial Corridor Overlay standards menu boards cannot be visible from SE University Avenue. Callout possible drive-thru window. Engineers Response: 15. Provide building dimensions. Engineers Response: 16. Provide dimensions for the patio. Based on anticipated occupant load for the patio a fence/railing will be required. Swing gates must swing in the direction of travel and have appropriate panic hardware. The occupant load dictates that an additional egress/gate is required. Provide a detail of the railing. Engineers Response: 17. Please clarify what the rectangular bump out on the east side of the building is. Will this cooler be attached to the building? Engineers Response: 18. Staff would note that additional exits for the restaurant will be required by the Building Code. Engineers Response: 19. Label all existing easements with recorded book and page numbers. Provide the book and page numbers for the existing electrical easement off of SE Bishop Drive. Engineers Response: 20. Show the streets/driveways on the north side of SE university Avenue that align with the proposed driveway (show on all sheets). Please show the streets/access across from this site as lining up. Engineers Response: 21. Indicate the type of driveway proposed off of SE Bishop Drive. Must be a Type A with radii. Also provide a detail. Engineers Response: 22. Indicate locations of street lights along SE Bishop Drive. Attached is the approved street light plan for SE Bishop Drive. Engineers Response: 23. A minimum of 200 feet separation shall be provided between monument signs. Engineers Response: SHEET 4 | UTILITY PLAN 24. Provide hydrant coverage radius (150’ radius). Engineers Response: 25. Indicate critical crossings with top and bottom of pipe elevations. Show critical crossing for water main crossing sanitary sewer service at northwest corner of site including top and bottom of pipe elevations. Show critical crossing information for water main crossing storm sewer in two locations at south side of site including top and bottom of pipe elevations. Engineers Response: 26. Indicate the location of the fire riser room. Please label this. Engineers Response: 27. Split the domestic and fire service outside of the building and provide valves on both. Provide valves on both the domestic and fire services. Engineers Response: 28. Identify electrical transformer location. Staff suggests contacting MidAmerican Energy early on to review proposed location to prevent any issues at the time of construction. Engineers Response: 29. Staff questions if gas service will be required for the proposed building. If so, indicate gas route and proposed meter location(s). The City of Waukee is the gas service provider. Please contact Tim Royer at 515-978-7920 to discuss gas route. Show the entire future gas route that was provided by the Gas Department. Engineers Response: 30. Indicate the size of the proposed grease interceptor. Engineers Response: 31. Utilize the existing water service that was installed for the lot. Engineers Response: 32. Show the existing sanitary service to the existing main on the east side of SE Bishop Drive. Engineers Response: 33. List pipe materials for utilities. Provide pipe materials for water and sanitary. Engineers Response: 34. Staff questions if the 12-inch storm pipes from ST-7A are for downspout connections. Provide a downspout connection detail. Engineers Response: 35. The sanitary service stub for Lot 2 should be run out of the manhole. Engineers Response: 36. The sanitary service to the building will need to be split from the grease interceptor line. Please identify this split on the outside of the building. As shown on the plans all sewage will flow through the grease interceptor. Engineers Response: SHEET 5 | GRADING PLAN 37. Demonstrate grades meet 2% slope in all unpaved areas. Show grades in all unpaved areas. Engineers Response: 38. Provide spot elevations at all building corners. Engineers Response: 39. Provide pedestrian facility information for ramps (running ramp grades, spot elevations, cross slope, etc.). Show turning spaces at top of all ramps and at sidewalk intersections including spot elevations and slope information for all sides. Show cross slope of south crosswalk in Area 1. Add ramp to west in Area 2. Correct running slope of sidewalk from building in Area 3. Will detectable warning panels be provided at ramps within the parking lot? Show turning spaces at connections to sidewalks along SE University Avenue and SE Bishop Drive including spot elevations and slope information for all sides. Revise turning space at intersection of sidewalks in south portion of Area 1 detail as sides exceed 2% slope. Show spot elevations and slope information at all sidewalk connections to the building. Engineers Response: 40. Indicate and illustrate 100 year flood elevations for detention and sump locations on the site. Show the 100 year for the pond and sump intakes. Illustrate the 100 year elevation for the detention pond. Engineers Response: 41. Provide a 3 foot high berm in the parking lot setback fronting SE University Avenue if feasible. Engineers Response: 42. Provide a detail for the FTM and TRM being installed at ST-18A FES outlet. Specify type of TRM required. Add a note that the FTM will be installed in accordance with the manufacturer’s specifications. Engineers Response: 43. The area in the right-of-way will need to be graded in accordance with the Waukee Standard Specifications for Public Improvements. The slop from the property line to the sidewalk should be 4%, sidewalk slope is to be 1.5% - +/- 0.5%, and slope from sidewalk to BOC is to be 4%. This may require existing utilities to be lowered. Add a note to coordinate utility relocations with utility providers. Engineers Response: SHEET 6 | EROSION & SEDIMENT CONTROL PLAN 44. Provide perimeter sediment control for the site. Engineers Response: 45. Provide downstream sediment control for the proposed topsoil stockpiled material. Engineers Response: 46. Provide the mix design for proposed seeding, fertilizing, and mulching. Engineers Response: SHEET 7 | LANDSCAPE PLAN 47. Staff would suggest providing additional plantings along the south property line to provide additional screening between the commercial building and the residential use to the south. Engineers Response: 48. Add a note to this sheet indicating that planting substitutions shall be approved in writing by the Waukee Development Services Department. Engineers Response: 49. Update the quantities for plantings along the south property line. It appears that 4 trees are plan, however only 2 are called out. Update the 2 TA to 3 TA in the southwest corner of the site. Engineers Response: 50. Label species of tree at southeast corner of the building. Engineers Response: 51. Provide additional screening behind the trash enclosure. Engineers Response: BUILDING ELEVATIONS 52. Provide colored elevations of the proposed building as part of the next submittal. Engineers Response: 53. Provide color elevations of the trash enclosure with the next submittal. Engineers Response: 54. Show the drive-thru window on the elevations, if planned. Engineers Response: 55. Per the adopted Planned Development Agreement, a minimum of 30% of the street facing façade at pedestrian level shall be fenestration. Please verify that this requirement has been met. Engineers Response: FIRE DEPARTMENT COMMENTS: Previous Fire Department comments have been addressed. MISCELLANEOUS COMMENTS: 56. Provide an Updated copy of the Construction Site SWPPP Review Checklist signed by the SWPP designer. Engineers Response: 57. Provide a copy of the SWPPP Prepared for obtaining General Permit #2 coverage. Engineers Response: 58. Provide a copy of the IDNR issued General Permit #2 authorization letter. Engineers Response: 59. Submit $250 fee for the COSESCO inspections. Engineers Response: The applicant will be required to provide the following as a part of the completion of the public improvements prior to approval of a final plat: Post Construction What practices considered for this site? 60. Provide a site plan specific to the storm water management facilities of the property indicating the permanent measures utilized by the designer and requirements for maintenance of said facilities. 61. A maintenance covenant will need to be created and provided for review (if different than the existing). 62. As-built plans of all storm water management facilities on site and a certification statement signed by SWPPP designer indicating that facilities were constructed as designed will be required. Staff would request that the revised plans and comment response letter be provided in digital form (PDF) and hard copies with 7 full-sized hard copies delievered to Waukee City Hall. The PDF copy may be emailed. Do not deliver plans to Veenstra & Kimm, City Staff will deliver plans to Veenstra & Kimm. Should you have any questions or concerns regarding these comments, please feel free to contact Brad Deets (515-978-7899), Andy Kass (515-978-7897) or myself at (515) 978-7898. Sincerely, Andy Kass, AICP Senior Planner 1"= 116.1016KMMEDCRMM01-13-17116.101688WAUKEE, IOWACOVE AT KETTLESTONE LOT 3 BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= kmarshpw:\\SAAPWIS01.snyder-associates.com:ProjectWise\Documents\2016_Projects\116.1016\Cadd\SP01_1161016_TSH.dgn2/23/20179:15:38 AMSnyder1:500pw:\\SAAPWIS01.snyder-associates.com:ProjectWise\Documents\Snyder\Printing\Pen_Tables\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS02/01/17JWM02/15/17JWMREVISED AS PER CITY COMMENTS1WILLIAMS POINTE PLAT 9 LOT 1 1185 SE UNIVERSITY AVE, WAUKEE PEOPLES TRUST & SAVINGS BANK 15705 UNIVERSITY, WAUKEE UNIVERSITY WOODS LLC 1410 SE ROSEWOOD CT, WAUKEE FAIRCHILD, AMANDA JORGENSEN WAUKEE 1185 SE ROSEWOOD DR LEJUKOLE, HENRY Y WAUKEE 1470 SE ROSEWOOD CT ORWENYO, JACQUELINE M JTRS OTUNDO, DANIEL B & WAUKEE 1450 SE ROSEWOOD CT MCCARTHY, SEAN T WAUKEE 1430 SE ROSEWOOD CT KITSIS, NATHAN J WAUKEE 1420 SE ROSEWOOD CT ATIYEH, CHELSEA WEST PARK PLAT 1 PARCEL A LOT 3 GERLICH, KAREN A ETAL 50% KAREN A & MARGARET L TRUST 50% WEST PARK PLAT 1 LOT 1 HAWTHORNE PLAZA, LLC3069 W A CO PL, W A UK EE H AK EM AN, D ALLA S D & LIN DA M J TR S 3101 W ACO PL, W AU KEE GIL ES, RIC HA RD W & CA RO LYN A GIL ES TRU STEES GIL ES, RIC HA RD W R EVO CA BL E TRU ST 3101 W AC O PL, W A UKEE GIL ES, RIC HA RD W & C ARO LYN A GIL ES TR USTEES GIL ES, RIC H ARD W REV OCA BLE T RUST 3069 W a co Pl W a ukee, IA 50263 HAK EM AN, LIN DA M WINHALL AT WILLIAMS POINTE CONDOMINIUMS 1273SF 1273SF 1226SF 1226SF 1226SF 1397SF 1226SF 1226SF 1273SF 1226SF 1226SF 1226SF 1226SF 1397SF 1273SF 1273SF 950SF 912SF 912SF 912SF912SF 912SF 950SF 950SF 912SF 912SF 912SF 912SF 950SF 912SF 912SF 912SF 912SF 950SF950SF 950SF 912SF 912SF 912SF 912SF 912SF 912SF950SF912SF912SF912SF912SF912SF950SF 950SF 950SF 912SF 912SF 912SF 912SF 950SF 950SF 912SF 912SF 912SF 912SF 950SF 950SF 912SF 912SF 912SF 912SF 912SF 912SF 950SF 1273SF 1226SF 1226SF 1226SF 1226SF 1273SF 1273SF 1226SF 1226SF 1226SF 1226SF 1273SF 1273SF 1226SF 1397SF 1226SF 1397SF 1397SF 1226SF 1273SF 1273SF 1226SF 1226SF 1226SF 1226SF 1226SF 1273SF 25' BUILDING SET BACK LINE 20' Rear Yard Setback20' Building Setback Li ne20' Building Set bac k Lin e661 SF 652 SF 652 SF 631 SF 682 SF 604 SF 604 SF 713 SF 679 SF 629 SF 652 SF 652 SF 604 SF 604 SF 713 SF 661 SF 652 SF 652 SF 604 SF 604 SF 661 SF 713 SF 652 SF 604 SF 652 SF 604 SF 604 SF 652 SF 604 SF 652 SF 652 SF 604 SF 713 SF 661 SF LOT7 LOT8 LOT9 LOT10 LOT11 LOT12 LOT13 LOT14 LOT15 LOT16 LOT17 LOT18 LOT19 LOT20 LOT21 LOT22 LOT23 LOT24 LOT25 LOT33 LOT32 LOT31 LOT30 LOT29 LOT28 LOT27 LOT26 LOT34 LOT35 LOT36 LOT37 LOT38 LOT41 LOT40 LOT39 LOT89LOT90LOT91LOT92LOT93LOT94LOT95LOT96LOT97LOT98LOT99LOT100LOT101LOT102LOT103 LOT69 LOT70 LOT71 LOT72 LOT73 LOT74 LOT75 LOT76 LOT77 LOT78 LOT79 LOT80 LOT81 LOT82 LOT68 LOT67 LOT66 LOT65 LOT64 LOT63 LOT62 LOT61 LOT60 LOT59 LOT58 LOT57 LOT56 LOT55 LOT54 LOT53 LOT52 LOT51 LOT50 LOT49 LOT48 LOT47 LOT46 LOT45 LOT44 LOT43 LOT42 LOT137 LOT136 LOT135 LOT134 LOT133 LOT132 LOT131 LOT130 LOT129 LOT118 LOT119 LOT128 LOT127 LOT120 LOT121 LOT126 LOT125 LOT122 LOT123 LOT124 LOT117 LOT104 LOT105 LOT116 LOT106 LOT115 LOT114 LOT107 LOT108 LOT113 LOT112 LOT109 LOT111 LOT110 LOT88 LOT86 LOT85 LOT84 LOT83 LOT87 INDEX OF SHEETS PROJECT LOCATION VICINITY MAP Date IOWALICENSEDPROFESSIO N ALEN GI NEERLicense Number Pages or sheets covered by this seal: My License Renewal Date is December 31, 2017 18954 18954 CANNON ERIC D.Eric D. Cannon, P.E. under the laws of the State of Iowa. licensed Professional Engineer supervision and that I am a duly by me or under my direct personal engineering document was prepared I hereby certify that this STATE OF IO WA PROFESSIO N ALLANDSCAPE AR CHITECTDate License Number Pages or sheets covered by this seal: 668 NO. ARCHITECT LANDSCAPE under the laws of the State of Iowa. Professional Landscape Architect charge. I am a duly licensed direct supervision and responsible below was prepared by me or under my this technical submission described I hereby certify that the portion of June 30, 2018 License Expires: 668 GULDENPFENNIG LARA F. Lara F. Guldenpfennig, ASLASE BRICK DRSE ALICE'S RDSE UNIVERSITY AVE.98TH STREETGRAND PRARIE PKWY1COVE AT KETTLESTONE LOT 3 TITLE SHEET1 OWNER PROJECT CONSTRUCTION MANAGER 8. 7. 6. 5. 4. 3. 2. 1.500'1"=500' DAVENPORT, IA 52807 4620 E 53RD ST, SUITE 200 WAUKEE INVESTMENTS I, INC. PHONE: (319) 512-2322 CONACT: BEN LOGSDON CORALVILLE, IOWA 52241 P.O. BOX 5462 625 1ST AVE, SUITE 201A BUILD TO SUIT, INC. CITY OF WAUKEE, DALLAS COUNTY, IOWA 1200 SE UNIVERSITY AVENUE FOR SITE PLAN LANDSCAPE PLAN SIDEWALK RAMP DETAILS EROSION AND SEDIMENT CONTROL PLAN GRADING PLAN UTILITY PLAN DIMENSION PLAN PROJECT INFORMATION TITLE SHEET 1"= 116.1016KMMEDCRMM01-13-17116.101688WAUKEE, IOWACOVE AT KETTLESTONE LOT 3 BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= kmarshpw:\\SAAPWIS01.snyder-associates.com:ProjectWise\Documents\2016_Projects\116.1016\Cadd\SP02_1161016_NTS.dgn2/23/20179:15:50 AMSnyder1:1pw:\\SAAPWIS01.snyder-associates.com:ProjectWise\Documents\Snyder\Printing\Pen_Tables\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS02/01/17JWM02/15/17JWMREVISED AS PER CITY COMMENTS12 2PROJECT INFORMATIONPARKING REQUIREMENTS: CONTROL POINTS 93 93.0 93 C OC FO E OE 4" G 4" HPG 8" W 8" S 12" ST12" ST G G AST UST Features Existing Proposed G EB W LEGEND 8" W(*) 8" S(*) 4" G(*) 4" HPG(*) C(*) OC(*) FO(*) E(*) OE(*) DUCT(*) 93.0 1 Soil Boring Mailbox Satellite Dish Sign Above Ground Storage Tank Underground Storage Tank Fence Post or Guard Post Gas Apparatus Gas Manhole Gas Valve Fiber Optic Handhole Fiber Optic Manhole Communication Handhole Communication Manhole Communication Pedestal Traffic Sign Electric Transformer Electric Box Yard Light Street Light Utility Pole with Transformer Utility Pole with Light Guy Anchor Utility Pole Well Water Service Valve Water Main Valve Fire Hydrant on Building Fire Hydrant Double Storm Sewer Intake Single Storm Sewer Intake Storm Manhole Storm Sewer with Size Sanitary Manhole (*) Denotes the survey quality service level for utilities Test Hole Location for SUE w/ID Duct Bank Sanitary Sewer with Size Water Main with Size High Pressure Gas Main with Size Gas Main with Size Overhead Electric Underground Electric Fiber Optic Overhead Communication Communication Coniferous Tree or Shrub Deciduous Tree or Shrub Tree Stump Tree Line Fence (Silt) Fence (Wood) Fence (Chain Link) Fence (Barbed, Field, Hog) Contour Elevation Spot Elevation UTILITY CONTACT INFORMATION SYSTEM, TICKET NUMBER 551501715. RECEIVED FROM THE IOWA ONE CALL DESIGN REQUEST UTILITY CONTACT FOR MAPPING INFORMATION SHOWN AS UTILITY WARNING UTILITY QUALITY SERVICE LEVELS THE TYPE, SIZE, CONDITION, MATERIAL, AND OTHER CHARACTERISTICS. BY ACTUAL EXPOSURE OR VERIFICATION OF PREVIOUSLY EXPOSED SUBSURFACE UTILITIES, AS WELL AS IS HORIZONTAL AND VERTICAL POSITION OF UNDERGROUND UTILITIES OBTAINEDQUALITY LEVEL (A) SUBSURFACE UTILITIES. GEOPHYSICAL METHODS TO DETERMINE THE EXISTENCE AND APPROXIMATE HORIZONTAL POSITION OF INFORMATION IS OBTAINED THROUGH THE APPLICATION OF APPROPRIATE SURFACE QUALITY LEVEL (B) QUALITY D INFORMATION. UTILITY FEATURES AND USING PROFESSIONAL JUDGMENT IN CORRELATING THIS INFORMATION WITH INFORMATION IS OBTAINED BY SURVEYING AND PLOTTING VISIBLE ABOVE-GROUND QUALITY LEVEL (C) INFORMATION IS DERIVED FROM EXISTING UTILITY RECORDS OR ORAL RECOLLECTIONS.QUALITY LEVEL (D) APPLICABLE, SIZE. THE QUALITY LEVELS ARE BASED ON THE CI / ASCE 38-02 STANDARD. QUALITY LEVELS OF UTILITIES ARE SHOWN IN THE PARENTHESES WITH THE UTILITY TYPE AND WHEN EXCEPT WHERE NOTED AS QUALITY LEVEL A. UTILITIES OR SUBSURFACE FEATURES SHOWN ARE IN THE EXACT LOCATION INDICATED SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE SUBSURFACE FEATURES SHOWN COMPRISE ALL SUCH ITEMS IN THE AREA, EITHER IN RECORDS OBTAINED. THE SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES OR THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR GENERAL NOTES Contact Email : troyer@waukee.org 515-978-7920 Tim Royer WAUKEE, CITY OF Gary@nexgencom.com 515-369-9000 Gary Reimers NEXGEN INTEGRATED COMMUNICATIONS Contact Email : troyer@waukee.org 515-978-7920 Tim Royer WAUKEE, CITY OF Thomas.sturmer@centurylink.com 303-664-8090 Tom Sturmer CENTURYLINK pmay@mediacomcc.com 515-246-2252 Paul May MEDIACOM COMMUNICATIONS CORP Joel.Schroeder@windstream.com 800-289-1901 JOEL SCHROEDER WINSTREAM MCLEOD MECDSMDesignLocates@midamerican.com 515-252-6632 Craig Ranfeld MIDAMER-ELEC jeff@netins.com 515-830-0445 Jeff Klocko IOWA NETWORK SERVICES Joni.McCabe@HickoryTech.com 507-387-1770 Joni McCabe HICKORY TECH GAS NO RESPONSE W-2 C-1 CLEAR C-2 OE/E C-2 FO1 1'BENCHMARKS IARTN DERIVED - US SURVEY FEET IOWA STATE PLANE SOUTH COORDINATE SYSTEM CP4 CP3 CP2 CP1 SE BISHOP DRIVE, EAST SIDE OF SITE. CUT "X" AT SOUTHEAST CORNER OF SIDEWALK ON WEST SIDE OF N=582877.86 E-1545330.84 EAST SIDE OF SE BISHOP DRIVE, NORTHEAST CORNER OF SITE. CUT "X" ON WEST END OF ISLAND IN UNIVERSITY AVENUE ON N=583274.75 E-1545387.19 EAST SIDE OF SE BRICK DRIVE, NORTH SIDE OF SITE. CUT "X" ON WEST END OF ISLAND IN UNIVERSITY AVENUE ON N=583276.66 E=1544730.94 EAST SIDE OF ALICE'S ROAD, NORTHWEST CORNER OF SITE. CUT "X" ON WEST END OF ISLAND IN UNIVERSITY AVENUE ON N=583274.48 E=1543827.85 IARTN DERIVED - US SURVEY FEET NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88 - GEOID12A) BM2 BM1 SOUTHEAST OF DOUBLE INTAKE, EAST SIDE OF SITE. BURY BOLT ON HYDRANT ON EAST SIDE OF SE BISHOP DRIVE 20' ELEV=1062.12 BISHOP DRIVE, EAST SIDE OF SITE. BURY BOLT ON HYDRANT SOUTH OF SIDEWALK ON WEST SIDE OF SE ELEV=1062.40 BULK REGULATIONS ZONING GENERAL USE IMPERVIOUS AREA PERVIOUS AREA LEGAL DESCRIPTION 66,085 SF 24,854 SF TOTAL AREA OF DISTURBANCE 2.09 AC BEING AN OFFICIAL PLAT DALLAS COUNTY, IOWA. LOT 3, COVE AT KETTLESTONE PLAT 1 RECORDED WITH BOOK 2015 PAGE 9498 COMMERCIAL DISTRICT) (COMMUNITY AND HIGHWAY SERVICE PLANNED UNIT DEVELOPMENT/ C-1 RETAIL/GENERAL COMMERCIAL ACCESSIBLE SPACES ) ( INCLUDING 6 HANDICAP 127 SPACES PROVIDED 126 SPACES REQUIRED (9800 SF / 1000 SF) x 4 SPACES = 40 SPACES RETAIL/ GENERAL COMMERCIAL: 86 SPACESRESTAURANT: (5740 SF / 1000 SF) x 15 SPACES = 4 SPACES PER 1000 SF OF RETAIL/GENERAL COMMERCIAL 15 SPACES PER 1000 SF OF RESTAURANT MINIMUM OPEN SPACE = 15% RESIDENTIAL REAR YARD = NONE EXCEPT FOR 25 FEET ADJACENT TO RESIDENTIAL SIDE YARD = NONE EXCEPT FOR 10 FEET ADJACENT TO LOT AREA = NONE FRONT YARD= ZERO (0') MINIMUM , NO MAXIMUM MAXIMUM NUMBER OF STORIES= 4 DENSITY = 30 DWELLING UNITS/ACRE MAXIMUM EE. CONTRACTOR IS TO COORDINATE ANY LANE/ROAD CLOSURES WITH THE CITY OF WAUKEE. CONSTRUCTION. DD. CONTRACTOR IS TO PROVIDE SHOP DRAWING SUBMITTALS OF CONSTRUCTION MATERIALS PRIOR TO CC. ALL FIRE HYDRANTS WILL BE REQUIRED TO HAVE STORZ FITTINGS. AND CITY OF WAUKEE ENGINEERING DEPARTMENT SHALL WITNESS ALL TIE-INS. BB. CONTRACTOR SHALL COORDINATE ALL TIE-IN TO UTILITIES WITH THE CITY OF WAUKEE ENGINEERING DEPARTMENT SLURRY FROM CONCRETE OPERATIONS TO DISCHARGE OFFSITE. AA. CONSTRUCTION OPERATIONS SHALL PROTECT STORM SEWERS AND DRAINAGE WAYS FROM ALLOWING CONCRETE SHALL WITNESS ALL TESTING. SPECIFICATIONS FOR PUBLIC IMPROVEMENTS AND ALL UTILITIES SHALL BE TESTED TO CITY STANDARDS. THE CITY Z. ALL UTILITIES INCLUDING PRIVATE UTILITIES SHALL BE CONSTRUCTED TO THE CITY OF WAUKEE STANDARD SHALL PROVIDE INFORMATION TO THE DESIGN ENGINEER FOR INCLUSION ON THE RECORD AS-BUILT DRAWINGS. GRADES FOR DRAINAGE SWALES, OVERFLOWS, ACCESSIBLE RAMPS AND DETENTION FACILITIES. THE CONTRACTOR Y. AS-BUILTS SHALL BE PROVIDED TO THE WAUKEE ENGINEERING DEPARTMENT INCLUDING ALL UTILITIES AND AS-BUILT EXPANSION JOINTS SHALL BE SEALED. JOINT BETWEEN SIDEWALKS AND PCC PAVEMENT. THE PCC RAMP JOINT LOCATED AT THE BACK OF CURB AND ALL X. PLACE 3/4" EXPANSION JOINT BETWEEN ALL PCC PAVEMENT/SIDEWALKS AND BUILDINGS. PLACE 1/2" EXPANSION W. ALL CONSTRUCTION TO EXISTING SANITARY MANHOLES SHALL BE CORE DRILL WITH A LINK SEAL. TO THE CITY OF WAUKEE. ALL SANITARY SEWER MANHOLES SHALL BE VACUUM TESTED. WAUKEE SHALL WITNESS ALL CLEANING AND TELEVISING. COPIES OF THE REPORT AND VIDEO SHALL BE PROVIDED V. ALL SANITARY SEWER AND STORM SEWER SHALL BE CLEANED AND TELEVISED PRIOR TO PAVING. THE CITY OF GRANTED APPROVAL IN WRITING BY THE CITY OF WAUKEE DEVELOPMENT SERVICES DEPARTMENT. U. THE CONTRACTOR IS RESPONSIBLE FOR ANY CHANGES MADE DURING CONSTRUCTION THAT HAVE NOT BEEN CITY OF WAUKEE DEVELOPMENT SERVICES DEPARTMENT PRIOR TO CONSTRUCTION. T. ANY CHANGES PROPOSED TO THE DRAWINGS DURING CONSTRUCTION SHALL BE APPROVED IN WRITING BY THE PEDESTRIAN FACILITIES. S. ALL STAKING SHALL BE DONE UNDER THE DIRECTION OF A LICENSED ENGINEER OR LAND SURVEYOR INCLUDING CONSTRUCTION ACTIVITIES BEGINNING. R. A PRE-CONSTRUCTION MEETING WITH THE CITY OF WAUKEE WILL BE REQUIRED A MINIMUM OF ONE WEEK PRIOR TO DISTANCE FROM THE WATER MAIN TO THE STORM SEWER IS AT LEAST TEN FEET. GREATER. O-RING GASKET JOINTS SHALL BE INSTALLED ON EACH SIDE OF THE CROSSING UNTIL THE NORMAL SEWER SHALL BE CONSTRUCTED OF REINFORCED CONCRETE WITH A FLEXIBLE O-RING GASKET RATED AT 13 PSI OR Q. IF STORM SEWER CROSSES ABOVE WATER MAIN OR CROSSES LESS THAN 18" BELOW A WATER MAIN THEN STORM SERVICES WITH UTILITY SERVICE PROVIDER, CITY OF WAUKEE, AND THE OWNER PRIOR TO CONSTRUCTION. P. CONTRACTOR TO COORDINATE NATURAL GAS, ELECTRICAL, TELEPHONE AND ANY OTHER FRANCHISE UTILITY SHALL BE MET BY CONTRACTOR. A COSESCO PERMIT IS REQUIRED FOR THIS PROJECT. MEASURES ON SITE AT THE TIME OF CONSTRUCTION. GRADING AND SOIL EROSION CONTROL CODE REQUIREMENTS NECESSARY. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR MAINTAINING ANY EXISTING EROSION CONTROL O. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING EROSION AND SEDIMENT CONTROL MEASURES AS SITE WORK. N. THE ADJUSTMENT OF ANY EXISTING UTILITY APPURTENANCES TO FINAL GRADE IS CONSIDERED INCIDENTAL TO THE EVENT. SIDEWALKS CAUSED BY CONSTRUCTION ACTIVITIES AT THE END OF EACH WORK DAY AND PRIOR TO A RAIN M. THE CONTRACTOR IS RESPONSIBLE FOR CLEANING DIRT AND DEBRIS FROM NEIGHBORING STREETS, DRIVEWAYS, AND (GUTTER), UNLESS OTHERWISE NOTED. L. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS SHOWN ARE FINISHED GRADES AND/OR TOP OF PAVING SLAB GRADES TO MEET SUDAS SPECIFICATIONS SECTION 2010 FOR TOPSOIL. K. CONTRACTOR TO STRIP AND STOCKPILE TOPSOIL FROM ALL AREAS TO BE CUT OR FILLED. RESPREAD TO FINISH INTO THE PROJECT TO AN APPROVED OFF-SITE WASTE SITE. J. CONTRACTOR TO LOAD AND TRANSPORT ALL MATERIALS CONSIDERED TO BE UNDESIRABLE TO BE INCORPORATED WAUKEE STANDARDS. ANY CHANGES COMPLETED WITHOUT APPROVAL ARE SUBJECT TO REMOVAL IN ORDER TO MEET THE CITY OF IMPROVEMENTS PRIOR TO CONSTRUCTION. CONTACT CITY OF WAUKEE FOR APPROVAL OF ANY CHANGES AND THAT STARTING CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LAYOUT VERIFICATION OF ALL SITE BETWEEN THIS PLAN AND FIELD CONDITIONS ARE TO BE REPORTED TO THE ARCHITECT/ENGINEER PRIOR TO THE TIME OF DESIGN. DEVIATIONS MAY BE NECESSARY IN THE FIELD. ANY SUCH CHANGES OR CONFLICTS I. DIMENSIONS, BUILDING LOCATION, UTILITIES AND GRADING OF THIS SITE ARE BASED ON AVAILABLE INFORMATION AT ACCORDINGLY ON THE AS-BUILT DOCUMENTS. H. ALL FIELD TILES ENCOUNTERED DURING CONSTRUCTION SHALL BE RECONNECTED OR REPAIRED AND NOTED PLANS SHALL GOVERN. G. IN THE EVENT OF A DISCREPANCY BETWEEN THE QUANTITY ESTIMATES AND THE DETAILED PLANS, THE DETAILED COMPACT TO 95% MAXIMUM DENSITY. F. CONSTRUCT MANHOLES AND APPURTENANCES AS WORK PROGRESSES. BACKFILL WITH SUITABLE MATERIAL AND PLANNED WEEKEND OR HOLIDAY WORK. ALSO NOTIFY THE CITY OF WAUKEE DEVELOPMENT SERVICES DEPARTMENT AT LEAST 48 HOURS PRIOR TO ANY E. NOTIFY OWNER, ENGINEER, CITY OF WAUKEE AT LEAST 48 HOURS PRIOR TO BEGINNING WORK. CONTRACTOR SHALL ANTICIPATED LANE CLOSURE. AND ACTIONS. THE CONTRACTOR SHALL NOTIFY THE CITY OF WAUKEE AT LEAST ONE WEEK PRIOR TO ANY ROADWAY, FLAGGERS SHALL BE PROVIDED. FLAGGERS SHALL CONFORM TO THE MUTCD IN APPEARANCE, EQUIPMENT UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). WHEN CONSTRUCTION ACTIVITIES OBSTRUCT PORTIONS OF THE D. ALL TRAFFIC CONTROL SHALL BE PROVIDED IN ACCORDANCE WITH REQUIREMENTS SET FORTH IN THE MANUAL ON STRUCTURE. C. LENGTH OF UTILITIES SHOWN ON PLANS ARE DIMENSIONED FROM CENTERLINE OF STRUCTURE TO CENTERLINE OF REPORTS PREPARED BY OTHERS. SPECIFICATIONS FOR PUBLIC IMPROVEMENTS, STATEWIDE URBAN DESIGN AND SPECIFICATIONS AND THE SOILS B. CONSTRUCTION OF ALL STREET AND UTILITY IMPROVEMENTS SHALL CONFORM TO THE WAUKEE STANDARD BE REPAIRED TO THE UTILITY OWNER'S SPECIFICATIONS AT THE CONTRACTOR'S EXPENSE. REMOVAL OR MODIFICATION. ANY DAMAGES TO UTILITY ITEMS NOT SHOWN FOR REMOVAL OR MODIFICATION SHALL EXACT LOCATION, AND DEPTH OF ALL UTILITIES. PROTECT ALL UTILITY LINES AND STRUCTURES NOT SHOWN FOR PROVIDERS AS NECESSARY DURING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXISTENCE, A. NOTIFY UTILITY PROVIDERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES AND COORDINATE WITH UTILITY 14 10 22 18 331.40' 331.40'306.20'10 11 (6 ACCESSIBLE STALLS) 126 STALLS PROVIDED LOT 2 101,474 SF 2.33 AC FFE=1061.70 18 10 13 600.B 500.B 400.B 300.B 200.B 100.C 100.D100.E100.A 200.A300.A400.A500.A600.A 100.F 700 100.B 1"= 116.1016KMMEDCRMM01-13-17116.101688WAUKEE, IOWACOVE AT KETTLESTONE LOT 3 BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= kmarshpw:\\SAAPWIS01.snyder-associates.com:ProjectWise\Documents\2016_Projects\116.1016\Cadd\SP03_1161016_DIM.dgn2/23/20179:15:53 AMSnyder1:30pw:\\SAAPWIS01.snyder-associates.com:ProjectWise\Documents\Snyder\Printing\Pen_Tables\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS02/01/17JWM02/15/17JWMREVISED AS PER CITY COMMENTS118 12 1310 SE BISHOP DRIVESE UNIVERSITY AVE. 10 11 2218 LOT 3 90,939 SF (6 ACCESSIBLE STALLS) 126 STALLS PROVIDED 9,800SF RETAIL 5,740SF RESTAURANT PATIO 13 FFE=1061.70 2.09 ACSE BRICK DR.COOLER UNITT FO BM1 BM2 CP2 CP3 CP4 24" RCP W F.E.S.=1050.30 F.L.=1055.64 6" CMP N F.L.=1052.91 15" RCP N F.L.=1052.41 24" RCP E F.L.=1052.26 30" RCP W Intake=1058.64 Rim=1059.41 F.L.=1056.45 6" CMP N F.L.=1054.42 12" RCP N F.L.=1054.37 24" RCP W Intake=1059.25 Rim=1059.97 12" RCP15" RCP15" RCP 18" RCP24" RCP 18" RCP 24" RCP 15" RCP15" PVC 15" PVC 15" PVC 12" PVC 12" P VC F.L.=1056.01 15" PVC E F.L.=1055.95 15" PVC W Intake=1060.93 F.L.=1055.09 15" PVC E F.L.=1054.99 15" RCP SW Intake=1060.89 F.L.=1054.73 15" RCP E Double Intake=1057.55 F.L.=1057.12 12" PVC NW Intake=1060.99 F.L.=1056.91 12" PVC W Bottom of Well=1056.01 Beehive Intake=1060.06 F.L.=1055.62 15" PVC E F.L.=1055.60 15" PVC W Intake=1059.87 F.L.=1054.42 18" RCP S F.L.=1054.39 24" RCP NE F.L.=1054.41 15" RCP W Double Intake=1057.31 Rim=1058.02 C 30" RCP 24" RCP 306.19'297.00' 297.00'306.19'(Bk.2015, Pg.20833) Existing 10' Public Utility Easement (Bk.2015, Pg.20833) And Water Main Easement Existing 30' Sanitary Sewer (Bk.2015, Pg.20833) Existing 15' Public Utility Easement (Bk.2015, Pg.20833) Existing Surface Water Flowage Easement (Bk.2015, Pg.20833) Existing 40' Ingress/Egress Easement Existing 10' Electric Easement DIMENSION PLANDIMENSION PLAN CONSTRUCTION NOTES 0 SCALE (FEET) 30 3 330'1A 1A 3C 3C 3C 3A 3B 3B 4A 4A 4A 4B4C 7A 3F 1B 3C 3F 2C 1B 1A 1B 2C 1B 1B 5.0'R15.0'R15.0'R15.0'R15.0'R15.0'R3.0'R 5 .0 'R3D 3D 5.0'R 4B 3G 15.0'R5.0'R5.0'R 15.0' R 5.0'R 9.0' 3F 5.0'R 5.0'R 5.0'R3.0'R 3.0'R 3.0'R9.0' TYP 3D 5.0'R 5.0'R 3C 3D 3D 5.0'R 3D 1A 15.0'R 15.0'R 31.0' 15.5'15.5' 25.5' 15.0'R 15.0'R5.0'R 24.0' 18.0'25.0' 3C 10.0'10.0' 6.0' 5.0'24.0'TYP 18.0'24.0'18.0'18.0'6.0'10.0'18.0'24.0'20.0'20.0'24.0'3F 3A 3A 3A3A 3A 3A 3B 3B 3A 3A 5.0' 6.0' 6 7 4 2 3 height: 0" to 2" Drop curb 5 DETAIL B 2 7Back of curb 1 R bar reinforcing #5 x 36" 1'-0" TYPICAL SECTION Curb Driveway SidewalkPr o pert y line TYPE A WITH RADII as specified Detail B Refer to curb Back of 8 2 'E' joint joint 'C' or 'E' 'B' joint 'C' joint 9 10 10 1'-0" min. Curb opening 18"12" 1'-0" Driveway width NO SCALE3 1 CONCRETE DRIVEWAY, TYPE A detectable warning panel with Engineer. Figure 7030.205; verify need for change requires a curb ramp, comply with sidewalk through driveway. If elevation transition from existing sidewalk to exceeds 2.0%, remove and replace to If cross slope of adjacent sidewalk panel passing space. driveway 5 feet wide to serve as a construct the sidewalk through the specified in the contract documents, maximum cross slope of 2.0%. If Target cross slope of 1.5% with a 2% toward center of alley. For alleys, invert the pavement crown 'B' joint is specified. Provide 'E' joint at back of curb unless 10 9 8 7 6 5 4 3 2 1 8 inches minimum. Match thickness of adjacent roadway, pavement. Center reinforcing bar vertically in the match thickness of driveway. Sidewalk thickness through driveway to minimum. Commercial and industrial: 7 inches Residential: 6 inches minimum. Pavement thickness. across sidewalk. of sidewalk. Do not extend raised curb end of taper/radius or at the front edge Transition the curb height to 0 inches at specified in the contract documents. Commercial and industrial: As maximum. Residential: 10 foot minimum,15 foot Driveway radius (R). 10.0' 10.0'5.0'6.0' 6.0'6.0'6.0'6.0'6.0'5.0'18.2'6.0'7C 7D 40.0'R 3I I. 6" GRANULAR TEMPORARY TURN AROUND WITH 12" PREPARED SUBGRADE. H. PARKING BARRIER. G. ENTRANCE APPROACH TO BE CONSTRUCTED AS PER STANDARD SPECIFICATIONS. TRAFFIC. WARNING SYSTEM AT RAMPS WHERE PEDESTRIAN TRAFFIC MEETS VEHICULAR PEDESTRIAN RAMP WITH A MAXIMUM SLOPE OF 8.33%. PROVIDE DETECTABLE F. E. INTEGRAL CURB. D. STANDARD CURB. C. PCC SIDEWALKS, 4" DEPTH PAVEMENT. STANDARD PROCTOR DENSITY. B. PCC DRIVES, 7" DEPTH PAVEMENT ON 12" DEPTH PREPARED SUBGRADE COMPACTED TO 95% COMPACTED TO 95% STANDARD PROCTOR DENSITY. A. PCC DRIVES AND PARKING, 6" DEPTH PAVEMENT ON 12" DEPTH PREPARED SUBGRADE 3. PAVEMENTS, PROVIDE THE FOLLOWING: C. REMOVE AND RELOCATE EXISTING HYDRANT B. PAVEMENT. A. GRIND CURB. 2. DEMOLITION, REMOVE THE FOLLOWING: EXPENSE WITH WORK BEING PREFORMED TO THE UTILITY OWNER'S SPECIFICATION. SCHEDULED FOR MODIFICATION OR DEMOLITION SHALL BE REMEDIED AT THE CONTRACTORS B. PROTECT EXISTING UTILITIES, ANY DAMAGE TO THE EXISTING UTILITIES THAT ARE NOT A. PAVEMENTS TO REMAIN. 1. EXISTING FEATURES, PROTECT THE FOLLOWING:15.0'R49.6'17.3'141.0'70.4'70.0'84.2'12.4'24.0'5.0'R 3 9.0'R1 0.0'R5.0'R 3D 5.0'R 5.0'R 3D TYP TYPTYP TYP3B 3A 3B88.0'3B 5.0' 12.0' 3.0' 3.0' 6B6B6B 6B 6B 6B 6B 6A THE SANITARY SEWER. SANITARY SEWER EASEMENT IF PAVEMENT NEEDS TO BE REMOVED FOR MAINTENANCE OF 8. THE CITY OF WAUKEE IS NOT RESPONSIBLE FOR PAVEMENT REPLACEMENT WITHING EXISTING D. COOLER UNIT SCREEN WALL. C. BIKE RACK LOCATION. B. MONUMENT SIGN. BY OTHERS. SEE ARCHITECTURAL AND ELECTRICAL PLANS FOR DETAILS. A. TRASH ENCLOSURES. 7. SITE AMENITIES, PROVIDE THE FOLLOWING: WITH THE OWNER ALL ASPECTS SITE LIGHTING PRIOR TO CONSTRUCTION. B.SITE LIGHTING SHOWN IS FOR ILLUSTRATION PURPOSES ONLY. CONTRACTOR TO COORDINATE ASPECTS OF ELECTRICAL SERVICE. A.CONTRACTOR TO COORDINATE WITH THE UTILITY OWNER AND PROPERTY OWNER ALL 6. SITE LIGHTING, PROVIDE THE FOLLOWING: A. PROVIDE VAN ACCESSIBLE PARKING SIGNAGE AS PER ADAAG REQUIREMENTS. 5. SIGNS, PROVIDE THE FOLLOWING: C. ACCESSIBLE AISLE. 45° STRIPING AT 3' ON CENTER SPACING WHERE SHOWN. B. PAINTED STATE OF IOWA APPROVED ACCESSIBLE PARKING SYMBOL. A. 4" WIDE PAINTED PARKING STALL LINES. 4. PAVEMENT MARKINGS, PROVIDE THE FOLLOWING: 4B 1B 7B 2A 3F 5A 5A 4A 3D 3C 3D4C 3D 3D 3C 3D 3D 3D 5A 3H 4B 4C 3F 600.B 500.B 400.B 300.B 200.B 100.C 100.D100.E100.A 200.A300.A400.A500.A600.A 100.F 700 100.B 10511052 10 5 3 105310541054105510551055 10 5 5 105510551056105610561057 1057 1058 1058 10 5 8 105810581058105910591059 1059 105910591059 10601060106010601060106010601060 1060 106010601060106010601060106010601060106 01060106010601060 1060 10 60 106010601060 10601060 10601060 1061106110611061106110611061 1061106110611061 10621062106210 6 21062 10621062 106210631063 10631063 10631063 10 6 4 1064 10641064 1064 1064 1065 1065 1065 10651066 14 10 22 18 331.40' 331.40'306.20'10 11 (6 ACCESSIBLE STALLS) 126 STALLS PROVIDED LOT 2 101,474 SF 2.33 AC FFE=1061.70 18 10 13 FO BM1 BM2 CP2 CP3 CP4 24" RCP W F.E.S.=1050.30 F.L.=1055.64 6" CMP N F.L.=1052.91 15" RCP N F.L.=1052.41 24" RCP E F.L.=1052.26 30" RCP W Intake=1058.64 Rim=1059.41 F.L.=1056.45 6" CMP N F.L.=1054.42 12" RCP N F.L.=1054.37 24" RCP W Intake=1059.25 Rim=1059.97 12" RCP15" RCP15" RCP 18" RCP24" RCP 18" RCP 24" RCP 15" RCP15" PVC 15" PVC 15" PVC 12" PVC 12" P VC F.L.=1056.01 15" PVC E F.L.=1055.95 15" PVC W Intake=1060.93 F.L.=1055.09 15" PVC E F.L.=1054.99 15" RCP SW Intake=1060.89 F.L.=1054.73 15" RCP E Double Intake=1057.55 F.L.=1057.12 12" PVC NW Intake=1060.99 F.L.=1056.91 12" PVC W Bottom of Well=1056.01 Beehive Intake=1060.06 F.L.=1055.62 15" PVC E F.L.=1055.60 15" PVC W Intake=1059.87 F.L.=1054.42 18" RCP S F.L.=1054.39 24" RCP NE F.L.=1054.41 15" RCP W Double Intake=1057.31 Rim=1058.02 C 30" RCP 24" RCP 306.19'297.00' 297.00'306.19'(Bk.2015, Pg.20833) Existing 10' Public Utility Easement (Bk.2015, Pg.20833) And Water Main Easement Existing 30' Sanitary Sewer (Bk.2015, Pg.20833) Existing 15' Public Utility Easement (Bk.2015, Pg.20833) Existing Surface Water Flowage Easement (Bk.2015, Pg.20833) Existing 40' Ingress/Egress Easement Existing 10' Electric Easement 150' HYDR ANT C OVE R AGE 150' HYDRANT COVERAGE EXISTING 150 ' HYDRANT COVERAGE 150 ' HYDRANT COVERAGE EXI STI NG 150' HYDRANT COVERAGE18 12 1310 SE BISHOP DRIVESE UNIVERSITY AVE. 10 11 2218 LOT 3 90,939 SF (6 ACCESSIBLE STALLS) 126 STALLS PROVIDED 9,800SF RETAIL 5,740SF RESTAURANT PATIO 13 FFE=1061.70 2.09 AC HHHHHSE BRICK DR.COOLER UNITGas T 8" PVC 8" PVC 8" PVC2"GAS 2"GAS2"GAS 2"GAS FUTURE 2"GAS FUTURE 2"GAS FUTURE 2"GAS1"= 116.1016KMMEDCRMM01-13-17116.101688WAUKEE, IOWACOVE AT KETTLESTONE LOT 3 BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= kmarshpw:\\SAAPWIS01.snyder-associates.com:ProjectWise\Documents\2016_Projects\116.1016\Cadd\SP04_1161016_ULT.dgn2/23/20179:15:56 AMSnyder1:30pw:\\SAAPWIS01.snyder-associates.com:ProjectWise\Documents\Snyder\Printing\Pen_Tables\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS02/01/17JWM02/15/17JWMREVISED AS PER CITY COMMENTS10 SCALE (FEET) 30 UTILITY PLAN4 430'INV=1054.72(OUT S) INV=1054.82(IN N) RIM=1061.00 ST-5A, TYPE SW-401 INV=1052.99(OUT W) INV=1053.09(IN E) RIM=1059.50 W/ TYPE 6 CASTING ST-11, TYPE SW-511 INV=1054.75(OUT W) INV=1054.85(IN NE) INV=1054.85(IN E) RIM=1059.50 W/ TYPE 6 CASTING ST-10, TYPE SW-502 UTILITY PLAN CONSTRUCTION NOTES INV=1054.23(OUT SW) INV=1056.40(IN E,W) INV=1054.33(IN E) RIM=1061.00 ST-7A, TYPE SW-401 INV=1051.99 W/ FOOTING AND APRON GUARD ST-18A, 30'' FES INV=1052.15(OUT SW) INV=1052.25(IN E) T/C=1059.50 W/ TYPE R CASTING ST-18, TYPE SW-502 INV=1055.59(OUT W) INV=1055.69(IN E) RIM=1059.50 W/ TYPE 6 CASTING ST-9, TYPE SW-511 INV=1056.70 INV=1053.2970 LF OF 6'' PVC @ 4.5%INV=1050.14 INV=1056.57(OUT W) RIM=1059.60 W/ TYPE 6 CASTING ST-1, TYPE SW-511 INV=1055.46(OUT W) INV=1055.56(IN E) RIM=1059.75 W/ TYPE 6 CASTING ST-4, TYPE SW-511 INV=1056.05(OUT W) INV=1056.15(IN E) INV=1056.19(IN S) RIM=1059.75 W/ TYPE 6 CASTING ST-3, TYPE SW-511 INV=1055.18(OUT S) INV=1055.28(IN E) T/C=1060.30 ST-5, TYPE SW-503 INV=1056.45 (OUT W) T/C=1060.00 ST-8, TYPE SW-501 17'X16' TRM 8'X12' FTM INV=1056.52(OUT N) INV=1048.68 (VERIFY PRIOR TO CONSTRUCTION) INV=1048.33 3A 3I 3A 2E 2C 2B 2A 2C 2D 3F 3E 2D 2F 3A GENERAL CONSTRUCTION NOTES TESTED AND DECHLORINATED. E. ALL WATERMAIN SHALL BE PRESSURE AND BACTERIA D. ALL SANITARY MANHOLES TO BE VACUUM TESTED. MANHOLES SHALL BE VACUUM TESTED. SHALL BE PROVIDED TO THE CITY OF WAUKEE. ALL SANITARY SEWER ALL CLEANING AND TELEVISING. COPIES OF THE REPORT AND VIDEO TELEVISED PRIOR TO PAVING. THE CITY OF WAUKEE SHALL WITNESS C. ALL SANITARY SEWER AND STORM SEWER SHALL BE CLEANED AND DEPARTMENT. TIE-INS SHALL BE WITNESSED BY THE CITY OF WAUKEE ENGINEERING SPECIFICATION FOR PUBLIC IMPROVEMENTS AND ANY TESTING OR B. ALL UTILITIES SHALL BE TESTED TO THE CITY OF WAUKEE STANDARD CONNECTING TO ANY PUBLIC UTILITY. A. NOTIFY THE CITY OF WAUKEE AT LEAST 48 HRS PRIOR TO w/ Reducer 8"X8" TEE w/ Reducer 6"x6" TEE 3A Plug 6" Service 6'' PVC @ 4.5% 34 LF OF 15 LF OF 12"PVC @ 2.0% 15 LF OF 12"PVC @ 2.0% 2A TP=1052.25(Water) BP=1053.81(ST) (TRANSITION MATS) OUTLET AND CHANNEL SCOUR PROTECTION SECTION VIEW SOIL COVER CULVERT OUTLET PROTECTION - PLAN VIEW (TYPICAL TRANSITION MAT APRON AT CULVERT OUTLET INTO CHANNEL) APPROPRIATE SOIL COVER EROSION WITH DOWNSTREAM SOILS FROM PROTECT BARE/DISTURBED SOIL COVER PROTECTION FOR DOWNSTREAM CALCULATOR TO COMPUTE USE NORMAL-DEPTH DIAMETER. HALF THE CULVERT UP TO A DEPTH AT LEAST AND BOTH SIDE SLOPES WIDTH OF CHANNEL (W) PROTECTION: BOTTOM RECOMMENDED WIDTH OF TRANSITION MATS TRANSITION MAT APRON LENGTH ANCHOR PATTERN OF FLOW DIRECTION EXTRA ANCHORS AS NEEDED FOR UNEVEN SOIL SURFACE. EXTRA ANCHORS AS NEEDED FOR LOOSE OR WET SOILS. USE A MINIMUM OF 8 ANCHORS PER MAT. ADJACENT MATS ABUT TOGETHER LATERALLY AND LONGITUDINALLY. TOP OF SCOURSTOP MATS SHOULD BE FLUSH WITH OR BELOW CULVERT. ABUT TRANSITION MATS TO END OF CULVERT OR CULVERT APRON. TRANSITION MAT WASHER LOCK RECESSED BULLET ANCHOR 36" ANCHOR STRAP ANCHOR ILLUSTRATION EXTRA ANCHORS AS NEEDED TO SECURE MAT TIGHTLY OVER SOIL COVER. MINIMUM DEPTH 24" IN LOOSE, SANDY OR WET SOIL. MINIMUM DEPTH 12" IN COMPACTED, COHESIVE SOIL. DRIVE ANCHOR INTO FIRM SOIL, PULL UP ON STRAP TO SET BULLET. NO SCALE FTM/TRM DETAIL LENGTH OF PROTECTION WIDTH OF PROTECTION4 1 4 TO CONSTRUCTION) (VERIFY PRIOR INV=1049.01 7 32 LF OF 30" HDPE @ 0.5% 100 LF OF 24" HDPE @ 0.74%100 LF OF 24" HDPE @ 0.66%7 6 L F OF 18 " HDP E @ 0 .5 0 %147 LF OF 18'' HDPE @ 0.50%151 LF OF 12" HDPE @ 0.50%76 LF OF 18" HDPE @ 0.50%72 LF OF 18" HDPE @ 0.50%46 LF OF 18" HDPE @ 0.40%121 LF OF 15" HDPE @ 0.40% 84 LF OF 12" HDPE @ 0.50%66 LF OF 8" HDPE @ 0.50%3H w/ Reducer 8"X8" TEE 25 LF OF 6" PVC @ 1.0% 5 TP=1049.06(SANITARY) BP=1053.75(WATER)Verify 6'' PVC @ 4.5% 33 LF OF FIRE RISER ROOM 7 INV=1056.70 INV=1056.70 3K 3C 3L 5 3B 6 3D 3J 5 6 3B 5 3G 7. TRANSFORMER LOCATION. COORDINATE WITH OWNER AND FRANCHISE UTILITY PROVIDER. 6. ROOF DRAIN COLLECTOR LINE. VERIFY LOCATIONS, SIZE AND ELEVATION WITH MECHANICAL PLANS. 5. CRITICAL CROSSING. CONTRACTOR TO VERIFY ALL CROSSINGS AND PROVIDE 18" MINIMUM SEPARATION. ACCORDINGLY. ARCHITECTURAL AND MECHANICAL PLANS FOR INTERIOR UTILITY ROUTING,METERS, DESIGN INFORMATION AND COORDINATE UTILITY CONNECTIONS 4. COORDINATE NATURAL GAS AND ELECTRICAL SERVICES AND METER LOCATION WITH UTILITY SERVICE PROVIDER PRIOR TO CONSTRUCTION. SEE L. 2" VALVE K. 6" VALVE J. REMOTE FIRE DEPARTMENT CONNECTION. COORDINATE WITH MECHANICAL PLANS. I. RELOCATED HYDRANT ASSEMBLY. H. REMOVE AND RELOCATE EXISTING HYDRANT ASSEMBLY. G. 8" WATER VALVE. F. HYDRANT ASSEMBLY. E. CONNECT TO EXISTING. CONTRACTOR TO VERIFY LOCATION AND DEPTH PROIR TO CONSTRUCTION. D. BUILDING WATER SERIVE CONNECTION. VERIFY LOCATION AND DEPTH WITH MECHANICAL PLANS PRIOR TO CONSTRUCTION. C. 2" DOMESTIC WATER SERVICE B. 6" WATER SERVICE LINE. A. 8" WATER SERVICE LINE WITH FITTINGS AND BENDS AS NECESSARY. MMINIMUM 5.5' DEEP. 3. WATER SERVICES, PROVIDE THE FOLLOWING: G. ADJUST SANITARY MANHOLE TO GRADE. F. CAP AND PLUG SANITARY SEWER SERVICE. E. GREASE INTERCEPTER. SEE MECHANICAL PLANS. D. CONNECT TO EXISTING 6" SANITARY SEWER. CONTRACTOR TO VERIFY LOCATION AND ELEVATION PRIOR TO CONSTRUCTION C. SANITARY SEWER CLEANOUT. B. CONNECT TO BUILDING SANITARY SERVICE. VERIFY LOCATION AND ELEVATION WITH MECHANICAL PLANS PRIOR TO CONSTRUCTION. A. 6" SANITARY SEWER SERVICE LINE @ MINIMUM 1.0% 2. SANITARY SEWER SERVICES; PROVIDE THE FOLLOWING: BE REMEDIED AT THE CONTRACTORS EXPENSE WITH WORK BEING PERFORMED TO THE UTILITY OWNER'S SPECIFICATION. A. PROTECT EXISTING UTILITES, ANY DAMAGE TO THE EXISTING UTILITIES THAT ARE NOT SCHEDULED FOR MODIFICATION OR DEMOLITION SHALL 1. EXISTING FEATURES, PROTECT THE FOLLOWING: Cap Gas Service 4 14 10 22 18 331.40' 331.40'306.20'10 11 (6 ACCESSIBLE STALLS) 126 STALLS PROVIDED LOT 2 101,474 SF 2.33 AC FFE=1061.70 18 10 13 FO BM1 BM2 CP2 CP3 CP4 24" RCP W F.E.S.=1050.30 F.L.=1055.64 6" CMP N F.L.=1052.91 15" RCP N F.L.=1052.41 24" RCP E F.L.=1052.26 30" RCP W Intake=1058.64 Rim=1059.41 F.L.=1056.45 6" CMP N F.L.=1054.42 12" RCP N F.L.=1054.37 24" RCP W Intake=1059.25 Rim=1059.97 12" RCP15" RCP15" RCP 18" RCP24" RCP 18" RCP 24" RCP 15" RCP15" PVC 15" PVC 15" PVC 12" PVC 12" P VC F.L.=1056.01 15" PVC E F.L.=1055.95 15" PVC W Intake=1060.93 F.L.=1055.09 15" PVC E F.L.=1054.99 15" RCP SW Intake=1060.89 F.L.=1054.73 15" RCP E Double Intake=1057.55 F.L.=1057.12 12" PVC NW Intake=1060.99 F.L.=1056.91 12" PVC W Bottom of Well=1056.01 Beehive Intake=1060.06 F.L.=1054.42 18" RCP S F.L.=1054.39 24" RCP NE F.L.=1054.41 15" RCP W Double Intake=1057.31 Rim=1058.02 C 30" RCP 24" RCP 18 12 1310 SE BISHOP DRIVESE UNIVERSITY AVE. 10 11 2218 LOT 3 90,939 SF (6 ACCESSIBLE STALLS) 126 STALLS PROVIDED 9,800SF RETAIL 5,740SF RESTAURANT PATIO 13 FFE=1061.70 2.09 AC HHHHHSE BRICK DR.COOLER UNITGas 8" PVC 8" PVC 8" PVC2"GAS 2"GAS2"GAS 2"GAS FUTURE 2"GAS FUTURE 2"GAS FUTURE 2"GAS10511052 10 5 3 105310541054105510551055 10 5 5 1055105610561057 1057 1058 1058 10 5 8 105810581058105910591059 1059 105910591059 10601060106010601060106010601060 1060 10601060106010601060106010601060106010 6 01060106010601060 1060 106 0 106010601060 10601060 10601060 1061106110611061106110611061 1061106110611061 1062106210 6 21062 10621062 106210631063 10631063 10631063 10 6 4 1064 10641064 1064 1064 1065 1065 1065 10651066306.19'297.00' 297.00'306.19'(Bk.2015, Pg.20833) Existing 10' Public Utility Easement (Bk.2015, Pg.20833) And Water Main Easement Existing 30' Sanitary Sewer (Bk.2015, Pg.20833) Existing 15' Public Utility Easement (Bk.2015, Pg.20833) Existing Surface Water Flowage Easement (Bk.2015, Pg.20833) Existing 40' Ingress/Egress Easement Existing 10' Electric Easement 100 YEAR ELEV.=1055.59 1059.43 1060.02 1060.09 1060.41 1058.441058.711058.751058.861058.931059 1059 1059.08 1059.21 1059.36 1059.43 1059.50 1059.50 1059.58 1059.60 1059.72 1059.75 1059.75 1059.75G 1060.25TC 1059.75 1059.75 1059.80 1059.80 1059.80 1059.90 1059.95G 1060.45TC 1059.95 1059.98 1060 1060 1060 1060 1060 1060 10601060 10601060.00 1060.00G 1060.50TC 1060.00G 1060.50TC 1060.04 1060.05 1060.05 1060.05 1060.051060.10 1060.15 1060.151060.20 1060.20 1060.20G 1060.70TC 1060.251060.25 1060.25 1060.25 1060.25G 1060.75TC 1060.25 H.P. 1060.25 1060.25 H.P. 1060.30 1060.30 1060.30G 1060.80TC 1060.30 1060.30 1060.35G 1060.85TC 1060.35 1060.40 1060.40 H.P. 1060.40 1060.40 1060.40 H.P. 1060.45 1060.45G 1060.95TC 1060.45G 1060.95TC 1060.50 1060.50 1060.50 1060.50 H.P. 1060.50 1060.50 1060.50G 1061.00TC 1061.50 1060.60 1060.60 1060.60 1060.60 1060.60G 1061.10TC 1060.60 1060.62 1060.65G 1065.15TC 1060.69 1060.69 1060.701060.70 1060.70 1060.70 1060.70 1060.70 1060.70 1060.75 1060.75G 1061.25TC 1060.80G 1061.30TC 1060.85 1060.90G 1061.40TC 1060.90G 1061.40TC 1060.90G 1061.40TC 1060.90G 1061.40TC 1060.90G 1060.90G 1061.40TC 1060.90G1060.90G1061.40TC 1060.90G 1061.40TC1060.90 1060.90 1060.90G1061.40TC 1060.90G 1061.40TC 1060.90G 1061.40TC 1060.95 10601061 1060 1061 1061 1061 1061.00G 1061.50TC 1061.00G 1061.50TC 1061.00G1061.50TC1061.00G 1061.50TC 1061.00G 1061.50TC 1061.02 1061.10G 1061.60TC H.P.1061.20 1061.28 1061.35TC1061.35TC1061.36 1061.40 1061.60 1061.60 1061.60 1061.68 1061.70 1061.70 1061.70 1061.70 1061.70 1061.701061.70 1061.70 1061.70 1061.70 1061.70 1061.70 1"= 116.1016KMMEDCRMM01-13-17116.101688WAUKEE, IOWACOVE AT KETTLESTONE LOT 3 BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= kmarshpw:\\SAAPWIS01.snyder-associates.com:ProjectWise\Documents\2016_Projects\116.1016\Cadd\SP05_1161016_GRA.dgn2/23/20179:16:01 AMSnyder1:30pw:\\SAAPWIS01.snyder-associates.com:ProjectWise\Documents\Snyder\Printing\Pen_Tables\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS02/01/17JWM02/15/17JWMREVISED AS PER CITY COMMENTS10 SCALE (FEET) 30 GRADING PLAN5 530'GRADING PLAN GENERAL NOTESPOLLUTION PREVENTION NOTES 1.0%2.8%1.0%1.0%1.0%1.0%2.1%1.0%2.0%1.0%1.0%1.0%1.0%1.0%1.0%2.0% 2.0%1.0%1.5% 1.0%1.0%1.1% 1.0%1.0%2.5%2.5%1.5%1.0%2.0% 6.0% 4.2%1.3%1.3% CONSTRUCTION ACTIVITIES. FROM STREETS, DRIVEWAYS, AND SIDEWALKS CAUSED BY F. THE CONTRACTOR IS RESPONSIBLE FOR CLEANING DIRT AND DEBRIS CUT OR FILLED. RESPREAD TO MINIMUM 8" DEPTH TO FINISH GRADES. E. CONTRACTOR TO STRIP AND STOCKPILE TOPSOIL FROM ALL AREAS TO BE SECTION. STRUCTURE TO CENTER OF STRUCTURE AND INCLUDE FLARED END D. ALL STORM SEWER PIPE LENGTHS ARE MEASURED FROM CENTER OF NOTED. GRADES AND/OR TOP OF PAVING SLAB (GUTTER), UNLESS OTHERWISE C. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS SHOWN ARE FINISHED COMPANIES DURING CONSTRUCTION. CONTRACTOR'S EXPENSE. COORDINATE AND COOPERATE WITH UTILITY CONTRACTOR'S CARELESSNESS SHALL BE CORRECTED AT THE AND SERVICES DURING CONSTRUCTION. ANY DAMAGE DUE TO THE LOCATION AND DEPTH OF ALL UTILITIES. AVOID DAMAGE TO UTILITIES CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXISTENCE, EXACT B. NOTIFY UTILITY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION. LOCATION INDICATED. DOES NOT WARRANT THAT THE UTILITIES SHOWN ARE IN THE EXACT IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEY FURTHER GUARANTEE THAT THE UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES INFORMATION AND/OR RECORDS OBTAINED. THE SURVEYOR MAKES NO THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY A. UTILITY WARNING: 1.5% 1.5% 1.5% THE CODE OF IOWA. REQUEST. FAILURE TO COMPLY WITH THE NPDES PERMIT REQUIREMENTS IS A VIOLATION OF THE CLEAN WATER ACT AND ITEMS, SHALL BE KEPT ON SITE AT ALL TIMES AND MUST BE PRESENTED TO ANY JURISDICTIONAL AGENCIES UPON INTENT, PROOF OF PUBLICATIONS, DISCHARGE AUTHORIZATION LETTER, CURRENT SWPPP, SITE INSPECTION LOG, AND OTHER 2. ALL DOCUMENTS RELATED TO THE STORM WATER DISCHARGE PERMIT, INCLUDING, BUT NOT LIMITED TO, THE NOTICE OF THE IDNR. STORM WATER POLLUTION PREVENTION PLAN (SWPPP) AND POSSIBLY OBTAINING THE GENERAL PERMIT COVERAGE FROM FULFILLMENT OF ALL REQUIREMENTS OF THE NPDES GENERAL PERMIT NO. 2 INCLUDING CREATING OR MAINTAINING THE (EPA). THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS ARE RESPONSIBLE FOR COMPLIANCE WITH AND ASSOCIATED WITH CONSTRUCTION ACTIVITIES FROM THE IDNR, AS REQUIRED BY THE ENVIRONMENTAL PROTECTION AGENCY 1. THIS PROJECT REQUIRES COVERAGE UNDER THE NPDES GENERAL PERMIT NO. 2 FOR STORM WATER DISCHARGES B. STORM WATER DISCHARGE PERMIT TO THE CONTRACTOR. PROPERTY, THE OWNER MAY, BUT NEED NOT, REMOVE SUCH ITEMS AND DEDUCT THE COST THEREOF FROM AMOUNTS DUE TO PROMPTLY REMOVE EARTH SEDIMENTATION OR DEBRIS WHICH COMES ONTO ADJOINING PUBLIC OR PRIVATE REASONABLE ATTORNEY FEES INCURRED TO OWNER. FURTHER, IF THE CONTRACTOR FAILS TO TAKE NECESSARY STEPS CLAIMS OF ANY TYPE WHATSOEVER RESULTING FROM DAMAGES TO ADJOINING PUBLIC OR PRIVATE PROPERTY, INCLUDING 2. DAMAGE CLAIMS: THE CONTRACTOR WILL HOLD THE OWNER AND ARCHITECT / ENGINEER HARMLESS FROM ANY AND ALL DEPOSIT AREAS DURING PERFORMANCE OR AS A RESULT OF PERFORMANCE. STEPS TO PROTECT AGAINST EROSION AND POLLUTION FROM THIS PROJECT SITE AND ALL OFF-SITE BORROW OR PERMIT, THE U.S. CLEAN WATER ACT AND ANY LOCAL ORDINANCES. THE CONTRACTOR SHALL TAKE ALL NECESSARY EROSION CONTROL REQUIREMENTS OF THE IOWA CODE, THE IOWA DEPARTMENT OF NATURAL RESOURCES (IDNR) NPDES 1. CODE COMPLIANCE: THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL POTENTIAL POLLUTION AND SOIL A. POLLUTION PREVENTION AND EROSION PROTECTION DISCONTINUATION". k. REMOVE ALL TEMPORARY EROSION CONTROL MEASURES AND SITE WASTE PRIOR TO FILING OF THE "NOTICE OF MUST BE CONTAINED ONSITE. BARRIERS AND DIRECT TO A SEDIMENT BASIN OR OTHER CONTROL DEVICE WHERE POSSIBLE. CONCRETE WASHOUT AND CONCRETE WASHOUT FACILITY. CONTROL RUNOFF FROM STAGING AREAS WITH DIVERSION BERMS AND/OR SILT FUELING / VEHICLE MAINTENANCE AREA, TEMPORARY SANITARY FACILITIES, MATERIALS STORAGE, UNLESS NOTED OTHERWISE, STAGING AREAS SHOULD CONTAIN THE FOLLOWING: JOB TRAILERS, j. COORDINATE LOCATIONS OF STAGING AREAS WITH THE OWNER AND RECORD IN THE SWPPP. MORE THAN 21 CALENDAR DAYS. LATER THAN 14 CALENDAR DAYS AFTER CONSTRUCTION ACTIVITY HAS FINISHED OR IS PLANNED TO BE DELAYED SOON AS PRACTICAL UPON COMPLETION OR DELAY OF GRADING OPERATIONS. INITIATE STABILIZATION MEASURES NO i. STABILIZE UNDEVELOPED, DISTURBED AREAS WITH MULCH, TEMPORARY SEED MIX, PERMANENT SEED MIX, OR SOD AS BUILDINGS OR OTHER IMPROVEMENTS ARE LOCATED TO MEET SUDAS SPECIFICATIONS SECTION 2010 FOR TOPSOIL. h. RESPREAD TOPSOIL (INCLUDING TOPSOIL FOUND IN SOD) ON ALL DISTURBED AREAS, EXCEPT WHERE PAVEMENT, SEWERS ARE INSTALLED. ENSURE CONTINUOUS RUNOFF CONTROL. PROVIDE INLET AND OUTLET CONTROL MEASURES AS SOON AS STORM OR RIPRAP AS SOON AS AREAS REACH THEIR FINAL GRADES AND AS CONSTRUCTION OPERATIONS PROGRESS TO g. INSTALL NECESSARY CONTROL MEASURES SUCH AS SILT BARRIERS, EROSION CONTROL MATS, MULCH, DITCH CHECKS ACCUMULATION OF EARTH OR DEBRIS IMMEDIATELY AND TAKE REMEDIAL ACTIONS FOR FUTURE PREVENTION. PROPERTIES, INCLUDING STREETS, DRIVEWAYS, SIDEWALKS, DRAINAGEWAYS, OR UNDERGROUND SEWERS. REMOVE ANY f. PREVENT ACCUMULATION OF EARTH AND DEBRIS FROM CONSTRUCTION ACTIVITIES ON ADJOINING PUBLIC OR PRIVATE SWPPP AND IMPLEMENT ANY RECOMMENDED MEASURES WITHIN 7 DAYS. THE SWPPP WITH A COPY SUBMITTED WEEKLY TO THE OWNER OR ENGINEER DURING CONSTRUCTION. REVISE THE EVERY SEVEN CALENDAR DAYS. RECORD THE FINDINGS OF THESE INSPECTIONS AND ANY RESULTING ACTIONS IN e. INSPECT THE PROJECT AREA AND CONTROL DEVICES (BY QUALIFIED PERSONNEL ASSIGNED BY THE CONTRACTOR) DEVICES WHEN THE MEASURES HAVE LOST 50% OF THEIR ORIGINAL CAPACITY. REPAIRING, REPLACEMENT, AND SEDIMENT REMOVAL THROUGHOUT THE PERMIT PERIOD. CLEAN OR REPLACE SILT CONTROL d. MAINTAIN ALL TEMPORARY AND PERMANENT EROSION CONTROL MEASURES IN WORKING ORDER, INCLUDING CLEANING, DISTURBED BY CONSTRUCTION OPERATIONS AT ANY TIME. c. PRESERVE EXISTING VEGETATION IN AREAS NOT NEEDED FOR CONSTRUCTION AND LIMIT TO A MINIMUM THE TOTAL AREA OPERATIONS. OR SEDIMENTATION BASINS DOWNSTREAM OF SOIL DISTURBING ACTIVITIES PRIOR TO SITE CLEARING AND GRADING b. INSTALL PERIMETER AND FINAL SEDIMENT CONTROL MEASURES SUCH AS SILT BARRIERS, DITCH CHECKS, DIVERSION BERMS, INCREASE SEDIMENT REMOVAL AND MAXIMIZE STORM WATER INFILTRATION, AND MINIMIZE SOIL COMPACTION. AND MAINTAIN NATURAL BUFFERS AROUND SURFACE WATERS, DIRECT STORM WATER TO VEGETATED AREAS TO a. UTILIZE OUTLET STRUCTURES THAT WITHDRAW WATER FROM THE SURFACE WHEN DISCHARGING FROM BASINS, PROVIDE INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING BMP'S UNLESS INFEASIBLE OR NOT APPLICABLE: 4. THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL REQUIREMENTS OF THE GENERAL PERMIT AND SWPPP, THE PROJECT SITE. 3. THE SWPPP AND SITE MAP SHOULD BE EXPEDITIOUSLY REVISED TO REFLECT CONSTRUCTION PROGRESS AND CHANGES AT BMP'S FROM THOSE SHOWN ON THE PLAN MAY BE REQUIRED. CONSTRUCTION ACTIVITIES ARE THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY, NOTE AND IMPLEMENT. ADDITIONAL PROJECT'S NPDES PERMIT COVERAGE. ALL BMP'S AND EROSION CONTROL MEASURES REQUIRED AS A RESULT OF 2. THE SWPPP ILLUSTRATES GENERAL MEASURES AND BEST MANAGEMENT PRACTICES (BMP) FOR COMPLIANCE WITH THE POLLUTION PREVENTION PLAN MADE DURING CONSTRUCTION. DRAWINGS. THE CONTRACTOR SHOULD REFER TO THE SWPPP FOR ADDITIONAL REQUIREMENTS AND MODIFICATIONS TO THE 1. THE STORM WATER POLLUTION PREVENTION PLAN (SWPPP) IS A SEPARATE DOCUMENT IN ADDITION TO THESE PLAN C. POLLUTION PREVENTION PLAN: NOTICE OF DISCONTINUATION. COPY AND PROVIDE THE ORIGINAL DOCUMENTS TO THE OWNER UPON PROJECT ACCEPTANCE AND/OR SUBMITTAL OF THE BE RETAINED FOR A PERIOD OF THREE YEARS AFTER PROJECT COMPLETION. THE CONTRACTOR SHALL RETAIN A RECORD REMOVAL OF ALL TEMPORARY EROSION CONTROL MEASURES. ALL PLANS, INSPECTION REPORTS, AND OTHER DOCUMENTS MUST 3. A "NOTICE OF DISCONTINUATION" MUST BE FILED WITH THE IDNR UPON FINAL STABILIZATION OF THE DISTURBED SITE AND 0.90%4.0% Typical Slope 4.0% Typical Slope 4.0% Typical Slope 4.0% Typical Slope 1"= 116.1016KMMEDCRMM01-13-17116.101688WAUKEE, IOWACOVE AT KETTLESTONE LOT 3 BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= kmarshpw:\\SAAPWIS01.snyder-associates.com:ProjectWise\Documents\2016_Projects\116.1016\Cadd\SP06_1161016_ERO.dgn2/23/20179:16:05 AMSnyder1:30pw:\\SAAPWIS01.snyder-associates.com:ProjectWise\Documents\Snyder\Printing\Pen_Tables\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS02/01/17JWM02/15/17JWMREVISED AS PER CITY COMMENTS118 12 1310 SE BISHOP DRIVESE UNIVERSITY AVE. 10 11 2218 LOT 3 90,939 SF (6 ACCESSIBLE STALLS) 126 STALLS PROVIDED 9,800SF RETAIL 5,740SF RESTAURANT PATIO 13 30" ST 24" ST 12"ST 12"ST18" ST18" ST18" ST 12" ST 15" ST18" ST 12" ST 8" STFFE=1061.70 2.09 AC HHHHHSE BRICK DR.COOLER UNITGas 24" ST 18 "S T 8" PVC 8" PVC 8" PVC2"GAS 2"GAS2"GAS 2"GAS FUTURE 2"GAS FUTURE 2"GAS FUTURE 2"GAS10511052 10 5 3 105310541054105510551055 10 5 5 105510551056105610561057 105 7 1058 1058 10 5 8 105810581058105910591059 1059 105910591059 10601060106010601060106010601060 1060 1060106010601060106010601060106010601 0 601060106010601060 1060 106 0 106010601060 10601060 10601060 1061106110611061106110611061 1061106110611061 10621062106210 6 21062 10621062 106210631063 10631063 10631063 10 6 4 1064 10641064 1064 1064 1065 1065 1065 10651066 FO BM1 BM2 CP2 CP3 CP4 24" RCP W F.E.S.=1050.30 F.L.=1055.64 6" CMP N F.L.=1052.91 15" RCP N F.L.=1052.41 24" RCP E F.L.=1052.26 30" RCP W Intake=1058.64 Rim=1059.41 F.L.=1056.45 6" CMP N F.L.=1054.42 12" RCP N F.L.=1054.37 24" RCP W Intake=1059.25 Rim=1059.97 12" RCP15" RCP15" RCP 18" RCP24" RCP 18" RCP 24" RCP 15" RCP15" PVC 15" PVC 15" PVC 12" PVC 12" P VC F.L.=1056.01 15" PVC E F.L.=1055.95 15" PVC W Intake=1060.93 F.L.=1055.09 15" PVC E F.L.=1054.99 15" RCP SW Intake=1060.89 F.L.=1054.73 15" RCP E Double Intake=1057.55 F.L.=1057.12 12" PVC NW Intake=1060.99 F.L.=1056.91 12" PVC W Bottom of Well=1056.01 Beehive Intake=1060.06 F.L.=1055.62 15" PVC E F.L.=1055.60 15" PVC W Intake=1059.87 F.L.=1054.42 18" RCP S F.L.=1054.39 24" RCP NE F.L.=1054.41 15" RCP W Double Intake=1057.31 Rim=1058.02 C 30" RCP 24" RCP (Bk.2015, Pg.20833) Existing 10' Public Utility Easement (Bk.2015, Pg.20833) And Water Main Easement Existing 30' Sanitary Sewer (Bk.2015, Pg.20833) Existing 15' Public Utility Easement (Bk.2015, Pg.20833) Existing Surface Water Flowage Easement (Bk.2015, Pg.20833) Existing 40' Ingress/Egress Easement Existing 10' Electric Easement 14 10 22 18 331.40' 331.40'306.20'10 11 (6 ACCESSIBLE STALLS) 126 STALLS PROVIDED LOT 2 101,474 SF 2.33 AC FFE=1061.70 18 10 13 10591059 1060 1060 1060 1060 1060 1060 10601060 106010601061 1060 1061 1061 1061 0 SCALE (FEET) 30 6 630'EROSION AND SEDIMENT CONTROL PLANSTORMWATER MANAGEMENT QUANTITIES ATTACHMENT TO POST Fabric Post cable ties Wire or 5 TYPICAL SILT FENCE DITCH CHECK F o resl opeVariable (20' for a normal 10' wide ditch.) (5'-0" max.) Post spacing (5'-0" max.) Post spacing 4 5 1 3 Backslope 902 904 906 908 910 TYPICAL SILT FENCE INSTALLATION ON LONGITUDINAL SLOPES individual section of silt fence Install "J-hook" at each end of an ground contour Install parallel to (Plan View) (600' if slope is flatter than 5%) 200' max. length per section documents or as directed by the Jurisdictional Engineer. Section 9040, 3.07 and at locations shown in the contract Install silt fence according to the requirements of GENERAL NOTES: 1 2 3 4 5 Insert 12 in. of fabric a minimum of 6 in. deep (fabric may be folded below the ground line) Compact ground by driving along each side of the silt fence as required to sufficiently secure the fabric in the trench to prevent pullout and flow under the fence. In ditches, extend silt fence up side slope so the bottom elevation at the end of the fence is a minimum of 2 in. higher than the top of the fence in the low point of the ditch. Steel posts to be embedded 20 in. unless otherwise allowed by the Jurisdictional Engineer. Secure top of engineering fabric to steel posts using wire or plastic ties (50 lb. min.). See details of "Attachment to Posts." TYPICAL SILT FENCE INSTALLATION ON LONGITUDINAL SLOPES Ground line Fabric Flow 4'-0" minimum 'T' steel fence post (Profile View) 4 1 1 2 See plans for spacing NO SCALE SILT FENCE DETAIL Ground line Fabric 1 5 4 or as required to adequately support fence Reduce post spacing to 5'-0" at water concentration areas, 8'-0"spacing 24"DETAILS OF SILT FENCE ON LONGITUDINAL SLOPES36"6 1 4.50 ACDISTURBED AREA TYPE 1 PERMANENT LAWN MIXTURE 4.50 AC SEEDING, FERTILIZING & MULCHING 4.50 AC SEDIMENT BASKETS 9 EA SILT FENCE 1640 LF BASKET SEDIMENT ENGINEER) (FIELD VERIFY WITH WASHOUT LOCATION APPROX. CONCRETE ENTRANCE/EXIT CONSTRUCTION STABILIZED WITH PROPERTY OWNER) (COORDINATE SIZE & FINAL LOCATION APPROX. TOPSOIL LOCATION BASKET SEDIMENT BASKET SEDIMENT BASKET SEDIMENT BASKET SEDIMENT BASKET SEDIMENT BASKET SEDIMENT BASKET SEDIMENT BASKET SEDIMENT 11'x17' TRM 8'x12' FTM Q=28.67 CFS EXISTING DETENTION BASIN DISCHARGE LOCATION TO SILT FENCE(TYP) SILT FENCE(TYP) SILT FENCE(TYP) SILT FENCE(TYP) 100YR EL=1060.25 100YR EL=1060.25 100YR EL=1060.50 100YR EL=1060.50 100YR EL=1060.50 100YR EL=1060.40 100YR EL=1060.40 PROPERTY OWNER) (COORDINATE WITH STAGING AREA 100YR EL=1060.50 100YR EL=1060.25 100YR PONDING EL=1055.59 DETENTION BASIN 9,800SF RETAIL 5,740SF RESTAURANT PATIO COOLER UNITCP3 1"= 116.1016KMMEDCRMM01-13-17116.101688WAUKEE, IOWACOVE AT KETTLESTONE LOT 3 BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= kmarshpw:\\SAAPWIS01.snyder-associates.com:ProjectWise\Documents\2016_Projects\116.1016\Cadd\SP07_1161016_DTL.dgn2/23/20179:16:10 AMSnyder1:10pw:\\SAAPWIS01.snyder-associates.com:ProjectWise\Documents\Snyder\Printing\Pen_Tables\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS02/01/17JWM02/15/17JWMREVISED AS PER CITY COMMENTS1RAMP AREA 1 RAMP AREA 2 RAMP AREA 3 RAMP AREA 4 SIDEWALK RAMP AREA 1 DETAIL 1"=10' SIDEWALK RAMP AREA 2 DETAIL 1"=10' SIDEWALK RAMP AREA 3 DETAIL 1"=10' SIDEWALK RAMP AREA 4 DETAIL 1"=10' SIDEWALK RAMP AREA 5 DETAIL 1"=10' X X XX X X XX X X XX X X XX X X X X X X XX X X X XXXXX X X X X X XX X XX X X X X X XX X X X X X X X X X X X X X X XX XX XX X X XX X X XX SIDEWALK RAMP DETAILS7 710'1060.90 1060.80 1061.60 1061.50 1060.40 1061.45 1061.40 106 1 .3 0 1060.45 1060.39 1059.95 1059.89 1059.58 1059.08 1058.86 1059.36 1059.21 1058.71 1058.93 1059.43 1061.401060.901060.90 1061.501061.50 1061.001061.001061.501061.501061.701061.701061.48 1061.40 1060.69 1060.75 1060.60 1060.66 1061.161061.10 1061.191061.251061.25 1061.34 1061.40 1060.30 1060.80 1060.80 1060.30 1060.50 1061.001061.10 1060.60 1060.40 1060.90 1060.90 1060.40 1061.50 1061.40 1060.90 1060.90 1060.90 1060.90 1061.50 1061.60 1061.701061.60 1061.60 1061.701061.70 1061.60 1061.70 1061.60 1061.00 1061.70 1061.001061.00 SE UNIVERSITY AVE.SE BISHOP DRIVERAMP AREA 5 X 1061.00 XX 1061.00 1061.40 1.5% 1.5% 1.5% 1.5% 1.5%5.0%5.0%5.0%5.0%1.5%1.5%1.5%1.5%1.5%1.5%1.5%1.5%7.9%7.9%7.9%7.9%6.3% 6.3%7.5% 7.5%1.5%1.5%1.5%6.3% 6.3%1.5%1.5%6.3% 6.3%1.5%1.5%1.5%1.5%6.3%1.0%6.3%1.0%6.3%6.3%1.0% 1.0%1.5%1.5%6.3%6.3%1.5% 1.5%6.3%6.3%1.5% 1.5%6.3%6.3%1.5% 6.3%1.5%6.3%1.5%1.5%1.5% 1.5%1.0%6.3% 6.3%1.0%1.5%0.9%0.9%1.5%4.1% 4.0%1.5%0.8%0.8%0.8%1.5% XX1059.68 1059.53 1.5%1.0%1.0%X X1059.46 1059.31 1.5%1.0%1.0%X X 1061.40 1061.50 0.0% 0.0%1.5%1.0%0.0% 0.0% X X1061.60 1061.50 X X 1060.45 1060.51 1.0% 1.0%1.0%X 1061.40 0.0% 0.0%1.5%1.5%X 1061.40 0.0% 0.0%1.0%X 1061.28 1.5% 1.5% X X 1061.19 1061.282.0%1.5%1.5% 0.0% X X1060.96 1060.86 1.0%1.0%1.0% X X 1.5%1.0%1.0%1060.861060.96 X X1061.301061.20 1.0%1.5%1.5% 1"= 116.1016KMMEDCRMM01-13-17116.101688WAUKEE, IOWACOVE AT KETTLESTONE LOT 3 BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= kmarshpw:\\SAAPWIS01.snyder-associates.com:ProjectWise\Documents\2016_Projects\116.1016\Cadd\SP08_1161016_LND.dgn2/23/20179:16:28 AMSnyder1:30pw:\\SAAPWIS01.snyder-associates.com:ProjectWise\Documents\Snyder\Printing\Pen_Tables\date.tblV8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.1REVISED AS PER CITY COMMENTS02/01/17JWM02/15/17JWMREVISED AS PER CITY COMMENTS118 12 1310 SE BISHOP DRIVESE UNIVERSITY AVE. 10 11 2218 LOT 3 90,939 SF (6 ACCESSIBLE STALLS) 126 STALLS PROVIDED 9,800SF RETAIL 5,740SF RESTAURANT PATIO 13 FFE=1061.70 2.09 AC HHHHH COOLER UNITGas T 2"GAS 2"GAS2"GAS 2"GAS FUTURE 2"GAS FUTURE 2"GAS FUTURE 2"GASFO BM1 BM2 CP3 CP4 24" RCP W F.E.S.=1050.30 F.L.=1055.64 6" CMP N F.L.=1052.91 15" RCP N F.L.=1052.41 24" RCP E F.L.=1052.26 30" RCP W Intake=1058.64 Rim=1059.41 F.L.=1056.45 6" CMP N F.L.=1054.42 12" RCP N F.L.=1054.37 24" RCP W Intake=1059.25 Rim=1059.97 12" RCP15" RCP15" RCP 18" RCP24" RCP 18" RCP 24" RCP 15" RCP15" PVC 15" PVC 15" PVC 12" PVC 12" P VC F.L.=1056.01 15" PVC E F.L.=1055.95 15" PVC W Intake=1060.93 F.L.=1055.09 15" PVC E F.L.=1054.99 15" RCP SW Intake=1060.89 F.L.=1054.73 15" RCP E Double Intake=1057.55 F.L.=1057.12 12" PVC NW Intake=1060.99 F.L.=1056.91 12" PVC W Bottom of Well=1056.01 Beehive Intake=1060.06 F.L.=1055.62 15" PVC E F.L.=1055.60 15" PVC W Intake=1059.87 F.L.=1054.42 18" RCP S F.L.=1054.39 24" RCP NE F.L.=1054.41 15" RCP W Double Intake=1057.31 Rim=1058.02 C 30" RCP 24" RCP (Bk.2015, Pg.20833) Existing 10' Public Utility Easement (Bk.2015, Pg.20833) And Water Main Easement Existing 30' Sanitary Sewer (Bk.2015, Pg.20833) Existing 15' Public Utility Easement (Bk.2015, Pg.20833) Existing Surface Water Flowage Easement (Bk.2015, Pg.20833) Existing 40' Ingress/Egress Easement Existing 10' Electric Easement 14 10 22 18 331.40' 331.40'306.20'10 11 (6 ACCESSIBLE STALLS) 126 STALLS PROVIDED LOT 2 101,474 SF 2.33 AC FFE=1061.70 18 10 13 LANDSCAPE PLAN0 SCALE (FEET) 30 8 830'PLANTING PLAN GENERAL NOTES LANDSCAPE REQUIREMENTS AND CALCULATIONS BOTANICAL NAMEKEY SHRUBSSIZE COMMENTS B&B AG AUTUMN BRILLANCE SERVICEBERRYAmelanchier x grandiflora 'Autumn Brilliance' B&B B&B CONT. (6' O.C.)JC PLANT SCHEDULE CONT. (6' O.C.)36" Ht. COMMON NAME Malus 'Spring Snow'SPRING SNOW CRABAPPLETREES 18" Ht. 24" Ht. 36" Ht. AT 8' HT. GB TREESUNDERSTORYPhysocarpus opulifolius 'Donna May'LITTLE DEVIL NINEBARK VD SB BLUES FESTIVAL ST. JOHN'S WORT Taxus x media 'Taunton'TAUNTON YEW Spiraea betulifolia 'Tor'TOR BIRCHLEAF SPIREA Acer tataricum 'Hot Wings' GT Gleditisia triacanthos var. inermis 'Skyline'B&B MA TA SKYLINE HONEYLOCUST PRINCETON SENTRY GINKGOGinkgo biloba 'Princeton Sentry' HOT WINGS TATARIAN MAPLE 1 1/2" SP 8' HT. 1 1/2" 1 1/2" 1 1/2" 8' HT. Viburnum dentatum 'Rastzam' Juniperus chinensis 'Sea Green'SEA GREEN JUNIPER RASPBERRY TART VIBURNUM CONT. (4' O.C.) CONT. (3' O.C.) CONT. (3' O.C.) HK PO Hypericum kalmianum 'Blues Festival' 24" Ht. 18" Ht. CONT. (3' O.C.) CS 18" Ht.CONT. (4' O.C.)Cornus sanguinea 'Cato'ARCTIC SUN DOGWOOD 24" Ht. 18" Ht. CO Calamagrostis x acutiflora 'Overdam'CONT. (3' O.C.) CA 24" Ht.CONT. (3' O.C.)& GRASSESPERENNIALS HE Calamagrostis x acutiflora 'Karl Foerster' Hemerocallis 'Royal Occasion' KARL FOERSTER FEATHER REED GRASS OVERDAM FEATHER REED GRASS ROYAL OCCASION DAYLILY CONT. (2' O.C.) AR 18" Ht.CONT. (4' O.C.)Aronia melanocarpa 'Morton'IROQUOIS BEAUTY BLACK CHOKEBERRY FG 18" Ht.CONT. (3' O.C.)Fothergilla gardenii DWARF FOTHERGILLA B&B B&B B&B CHINA SNOW PEKING LILAC Tilia americana 'Redmond' TT DEPARTMENT. H. PLANTING SUBSTITUTIONS SHALL BE APPROVED IN WRITING BY THE WAUKEE DEVELOPMENT SERVICES SERVICES DEPARTMENT. G. PLANTING SUBSTITUTIONS SHALL BE APPROVED IN WRITING BY THE WAUKEE DEVELOPMENT F. SOD ALL DISTURBED AREAS UNLESS NOTED OTHERWISE. PERIMETER, AND IN ALL AREAS INDICATED ON PLAN. E. PROVIDE 3-INCH DEPTH SHREDDED HARDWOOD MULCH AROUND ALL PLANTINGS TO A MIN. 3-FOOT DATE OF INSTALLATION. D. CONTRACTOR SHALL GUARANTEE ALL PLANT MATERIAL FOR A PERIOD OF ONE YEAR FROM STANDARDS FOR NURSERY STOCK" (ANSI Z60.1-LATEST EDITION). C. ALL PLANT MATERIAL SHALL AT LEAST MEET MINIMUM REQUIREMENTS SHOWN IN THE "AMERICAN WITH UTILITY COMPANIES DURING CONSTRUCTION. CARELESSNESS SHALL BE CORRECTED AT THE CONTRACTOR'S EXPENSE. COORDINATE AND COOPERATE TO UTILITIES AND SERVICES DURING CONSTRUCTION. ANY DAMAGE DUE TO THE CONTRACTOR'S FOR DETERMINING EXISTENCE, EXACT LOCATION AND DEPTH OF ALL UTILITIES. AVOID DAMAGE B. NOTIFY UTILITY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION. CONTRACTOR IS RESPONSIBLE UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED. THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEY FURTHER DOES NOT WARRANT THAT THE THE SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR RECORDS OBTAINED. A. UTILITY WARNING: 10-JV B&B8' HT.JV Syringa pekinensis 'Morton' Juniperus virginiana 'Skyrocket'SKYROCKET JUNIPER REDMOND AMERICAN LINDEN (6 TREES COUNTED TOWARDS OFF STREET PARKING REQUIREMENTS) STREET TREES MAY BE COUNTED TOWARDS OFF STREET PARKING REQUIREMENTS. 297 LF/40 LF = 7.42 STREET TREES REQUIRED (8 STREET TREES PROVIDED) 1 OVERSTORY TREE PER 40 LF OF FRONTAGE STREET TREE REQUIREMENT: THERE ARE NO BUFFER REQUIREMENTS. BUFFER REQUIREMENT: (3 TREES PROVIDED) PARKING LOT ISLANDS SHALL HAVE A MINIMUM OF 1 OVERSTORY TREE. OFF-STREET PARKING AREAS: FOUNDATION PLANTINGS ARE REQUIRED AT THE BASE OF ALL BUILDINGS FOUNDATION PLANTINGS: 27.28 REQUIRED (32 SHRUBS PROVIDED)2 SHRUBS x 13.641 PU'S = (7 UNDERSTORY TREES PROVIDED) 0.5 UNDERSTORY TREE x 13.641 PU'S = 7 REQUIRED 14 REQUIRED (14 OVERSTORY TREES PROVIDED)1 OVERSTORY TREE x 13.641 PU'S = 13,641/1,000 = 13.641 PLANT UNITS (PU'S) 21 TREES REQUIRED X 25% = 5.25 EVERGREEN TREES REQUIRED (10 PROVIDED) MINIMUM OF 25% OF TOTAL REQUIRED TREES SHALL BE EVERGREEN. REQUIRED OPEN SPACE. 1.0 OVERSTORY TREES, 0.5 UNDERSTORY TREES, AND 2.0 SHRUBS PER 1,000 SF OF 90,939 SF (TOTAL LOT) x 15% = 13,641 SF REQUIRED (23,915 SF PROVIDED - 26.3%) 15% OPEN SPACE REQUIRED AND THE KETTLESTONE DESIGN GUIDELINES PUD) (LANDSCAPE CALCULATIONS BASED UPON CITY OF WAUKEE ZONING CODE REQUIREMENTS 1-AT 1-SP 3-GB 5-HK 5-HK 11-PO 11-PO 16-HK14-PO 1-MA 1-MA 1-MA 3-SB 8-SB 8-SB7-FG 1-TT 1-TT 2-TT3-TT 3-TT 3-JC 3-JC 1-JC3-VD3-VD 8-CS 5-AR 26-HE 28-CA 1-GT 1-GB1-GB 3-TA 2-TA 2-GT 4-AG 10-CO 1-GB 4-FG 5-HK 5-HK 5-HK 5-HK 5-HK 1-AT1-AT1-AT 16-HK 1-SP1-SP1-SP 14-PO 14-PO 14-PO 14-HK 4-HK SE. UNIVERSITY AVE. ELEVATION REAR ELEVATION EAST ELEVATION WEST ELEVATION MAJOR MATERIALS FOR THE COVE AT KETTLESTONE NICHIHA VINTAGEWOOD BARK NICHIHA VINTAGEWOOD CEDAR PERFORATED GALVANIZED MESH EBONITE SMOOTH BRICK NICHIHA ILLUMINATION WHITE PAINTED 1 2 3 4 1 2 3 4 5 1 2 3 4 1 2 4 5 1 2 3 4 5 5 TRASH ENCLOSURE FRONT REAR SIDES BLACK PAINTED CMU6 55 5 666