Loading...
HomeMy WebLinkAbout2017-03-06-J03 Autumn Ridge Lot 1 Plat 1_SitePlan AGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: March 6, 2017 AGENDA ITEM: Consideration of approval of a resolution approving a site plan for Autumn Ridge Lot 1, Plat 1 [595 SE Alice’s Road] FORMAT: Resolution SYNOPSIS INCLUDING PRO & CON: MJG Development, LLC, requests approval of a site plan to allow the site improvements for the construction of a commercial building. The site plan identifies an 8,610 square feet multi-tenant commercial building to be constructed on a 2.02 acre lot located at the intersection of SE Alice’s Road and SE Olson Drive. The site plan identifies a Car-X Auto center and associated office and a separate tenant space for lease. Access to the property will be provided via an access off of SE Olson Drive. The applicant has provided elevations for proposed building on the site which meets the intent of the architectural guidelines within the Site Development and Building Standards Ordinance and the approved Planned Development Agreement for the property. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: Approval of a Site Plan for Autumn Ridge Lot 1 City Planner Melissa DeBoer introduced a request for approval of a site plan for a multi-tenant commercial building by the applicant, MJG Development LLC. Mrs. DeBoer advised that the subject property is located on the corner of SE Olson Drive and SE Alice’s Road and is approximately 2 acres in size. The request is for 2 tenant spaces equaling 8600 square feet in size that will include a Car-X auto service with the remaining 2,000 square foot tenant space with an unknown tenant at this time. The trash enclosure for the proposed building is located on the north east side of the parking lot. Access to the site will be provided off of Olson Drive and the site plan proposes 82 Parking spaces, 4 of which are handicap and 30 stalls within the service bays. This meets the Minimum parking requirements of 40 spaces. All utilities will be extended to the subject property. Gas and sanitary sewer will be provided from Alice’s Road and water will be provided to the Building from SE Olson Drive. Storm water detention is located in the basin on the north side of the lot. Mrs. DeBoer advised that 44% of the site is proposed as open space which meets requirements and the landscaping has been provided in compliance with the planting requirements. Mrs. DeBoer advised the proposed building will be constructed of a variety of materials including dark gray brick, Tan EIFS, aluminum and glass overhead doors and storefront, and gray metal panels. The proposed elevations meet the intent of the Site Plan Ordinance. At this moment staff recommends approval of the site plan subject to remaining staff comments. • Commissioner Hoifeldt questioned who owned the land to the north and east of the subject property. Mr. Deets advised that the City owns the parcels to the north and east. Commissioner Hoifeldt followed up with a question regarding the necessity of the Swale. Mr. Deets advised that the land is very flat so to achieve positive storm water drainage the Cement Flume was suggested to carry the water to the west. • Commissioner Schmidt questioned if that water would then drain into the SE Alice’s Road Storm Sewer System. Mr. Deets advised that was correct. • Commissioner Hoifeldt questioned the Applicant representation if they had any thoughts for the south end tenant. Representative for Car-X, Mark Goldner, advised that there had been discussions of Enterprise to pair with the Car-X, but at the moment, mothing was set in stone. Commissioner Fontenot moved to approve the site plan for Autumn Ridge Lot 1, subject to remaining staff comments. The motion was seconded by Commissioner Schmidt. Ayes: Stonebrook, Fontenot, Hoifeldt, and Schmidt. Nays: None. Motion Carries. STAFF REVIEW AND COMMENT: At this time all staff comments have been addressed and staff recommends approval. RECOMMENDATION: Approve the resolution ATTACHMENTS: I. Proposed Resolution II. Staff Report III. Staff Comment Letter IV. Site Plan V. Elevations PREPARED BY: Andy Kass, Senior Planner REVIEWED BY: THE CITY OF WAUKEE, IOWA RESOLUTION 17- APPROVING THE SITE PLAN FOR AUTUMN RIDGE LOT 1, PLAT 1 [595 SE ALICE’S ROAD] IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Site Plan for Autumn Ridge Lot 1, Plat 1, subject to remaining staff comments on February 28, 2017; AND, WHEREAS, the Site Plan for Autumn Ridge Lot 1, Plat 1 is in general conformance with §304 – Site and Building Development Standards Ordinance of the Waukee Municipal Code; AND, WHEREAS, the Site Plan for Autumn Ridge Lot 1, Plat 1 is in general conformance with §301.27(A) – Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND, NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 6th day of March, 2017 that the Site Plan for Autumn Ridge Lot 1, Plat 1 is approved, subject to remaining staff comments. ____________________________ William F. Peard, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk ROLL CALL VOTE AYE NAY ABSENT ABSTAIN Anna Bergman R. Charles Bottenberg Brian Harrison Shelly Hughes Larry R. Lyon STAFF REPORT TO: Planning and Zoning Commission PREPARED BY: Melissa DeBoer RE: Autumn Ridge Lot 1 Plat 1 – Site Plan DATE: February 28, 2017 GENERAL INFORMATION: Applicant: MJG Development, LLC. Requested Action Site Plan Approval Location and Size: Property is generally located north of SE Olson Drive and east of Alice’s Road and contains approximately 2 acres. LAND USES AND ZONING: Location Existing Land Use Comprehensive Plan Current Zoning Property in Question Undeveloped Community Village C-1 North Parkland / Trail Community Village C-1 South Vacant - Undeveloped Community Village C-1 East Apartments Community Village PD/R-3 West Vacant - Undeveloped Community Village PD/M-1 BACKGROUND: The subject property is located at the northeast corner of Alice’s Road and SE Olson Drive. The property in question is approximately 2 acres. The applicant, MJG Development, LLC., is requesting approval of a site plan for a multi-tenant retail/commercial building that will include a Car-X Auto Service. The remaining tenant space measures 2,000 square feet and the tenant is unknown at this time. February 24, 2017 2 of 3 ABOVE: Aerial of the site plan (outlined in RED) in relation to the surrounding properties. PROJECT DESCRIPTION: The proposed project includes the construction of a 8,600 square foot multi-tenant retail/commercial building. The site plan identifies two tenant spaces. The trash enclosure for the proposed building is located on the northeast side of the parking lot. The proposed exterior lighting for the site has been reviewed and is in compliance with the Site Plan Ordinance. ACCESS AND PARKING: Access to the site will be provided off of SE Olson Drive A total of 40 parking spaces are required for this facility. The total amount of parking proposed is 82 spaces – including 4 handicap accessible stalls and 30 stalls within the service bays. UTILITIES: All utilities will be extended to the subject property. Gas and sanitary sewer will be provided to the building from Alice’s Road. Water will be provided to the building from SE Olson Drive. Storm water detention will be provided in the detention basin located on the north side of the property. February 24, 2017 3 of 3 OPEN SPACE AND LANDSCAPING: A minimum of 20% of the project area is required to be open space and the site plan indicates that 44% open space will be provided. Landscaping has been provided in compliance with the required planting requirements. ELEVATIONS: The proposed building will be constructed of a variety of materials including dark gray brick, tan EIFS, aluminum and glass overhead doors and storefront, and gray metal panels. The proposed elevations meet the intent of the Site Plan Ordinance. STAFF RECOMMENDATION: At this time staff is comfortable with the site plan and would recommend approval of the site plan subject to remaining staff comments. CITY OF WAUKEE Melissa DeBoer, AICP Planner II Development Services Department 230 W. Hickman Road Waukee, IA 50263 Phone: (515) 978-9533 Fax: (515) 987-1845 1st Review: January 31, 2017 2nd Review: February 14, 2017 3rd Review: 4th Review: Snyder & Associates, Inc. Attn: Brent Culp 2727 SW Snyder Blvd Ankeny, IA 50023 RE: Autumn Ridge Plat 1, Lot 1 – Site Plan Dear Mr. Culp: Per your request, staff has reviewed the proposed site plan for Autumn Ridge Plat 1, Lot 1. The property is located at the northeast corner of Alice’s Road and SE Olson Drive. Based upon our review, staff has the following comments related to the site plan: COVER SHEET & GENERAL COMMENTS 1. Provide the address in the title block on this plan set. (595 SE Alice’s Road) 2. Include project manager contact information on the cover sheet. 3. Provide a photometric plan to include the values of the entire property, including two feet beyond the property lines. 4. Coordinate with Alice’s Road Phase 4 plans. Staff will send the line work for these future improvements once received from Foth. Engineers Response: SHEET 2 | PROJECT INFORMATION 5. Revise the zoning to C-1, delete Planned Unit Development as this property is not included in a planned development. 6. General Notes K, should meet SUDAS Specifications Section 2010 for minimum depth of topsoil. SHEET 3 | DIMENSION PLAN 7. Separate Dimension and Utility sheets. 8. Show dimensions of buildings. 9. All critical crossings should be called out with top and bottom of pipe elevations. 10. Indicate hydrant coverage (150’ radius) on this sheet. 11. Indicate the location of any ground mounted mechanical equipment. Project Name Project Engineer/Manager Project Type City Contact Autumn Ridge Plat 1, Lot 1 Brent Culp Site Plan Melissa DeBoer 12. Label the width of the sidewalk along SE Olson Drive. 13. Label the driveway off of SE Olson Drive as a Type A driveway and provide a detail. Update Note 3.G. to reference sheet 8. Engineers Response: 14. Staff questions if the proposed trash/tire enclosure will be enough storage for the trash, recycling, tires, and other car parts as necessary. Please address. Engineers Response: 15. Please revise Dimension Plan Construction Notes to reflect labels on the plan. Note 1.B. seems to be missing. Please address. Engineers Response: 16. Dimension Plan Construction Notes. Note 1. Change C to B. Engineers Response: SHEET 4 | UTILITY PLAN 17. Please relocate transformer so as not to be seen from the major road. Staff suggests coordinating with MidAmerican Energy on the location of the transformer. 18. Clarify water service sizes at split and whether or not what is shown are curb stops or valves. Each service line will need to be split again from each of the tenant spaces (fire and domestic). Label 2.E. to 2.H. on the utility plan. Engineers Response: 19. Staff questions if gas service is planned for this site. If so, please indicate the service route. 20. Label all existing easements with book and page numbers. 21. Provide the location of the sand/oil separator and include the size. 22. Please label the fire department connection on the plan. 23. Please provide a floor plan in order to show the location of the fire riser room / electrical room. 24. Provide more detail on sanitary service connection to existing main. Is there a stub coming out of MH to the north? Can an existing service wye be added to the end of this main to accommodate the service connection? 25. Show approximate invert elevations of 6” sanitary sewer service and detail of connection to existing sanitary sewer. 26. Adjust leader for Note “Remove Exst. 24” Storm Sewer Stub Connect to Existing Intake” so it points to appropriate 24” RCP pipe. 27. Call out downspout connections. Provide downspout connection detail on Sheet 7. Update Note 5.A. to reference sheet 8. Engineers Response: 28. Update existing cunette detail to match City of Waukee Concrete Flume Detail, STD DWG NO. 31 29. Update existing 6” standard curb detail to match City of Waukee 6” Curb Detail, STD DWG NO. 23 30. Label the water service sizes at split. 31. It appears the southwest corner of the parking lot extends into the storm sewer/overland flowage easement. Please address. SHEET 4 | GRADING PLAN 32. Demonstrate grades meet 2% slope in all unpaved areas. 33. Provide spot elevations at all building corners. 34. Provide blown up pedestrian facility information for ramps. Show slope information for all sides of pedestrian ramps and turning spaces including ramps within parking lot. Show cross slopes of all crosswalks. Show all detectable warning panels. Show spot elevations and slope information for ramp on west side of parking lot. Show cross slopes of all crosswalks. Will detectable warning panels be installed at ramps within parking lot? Engineers Response: 35. Where is detention being provided, please label on the plan. 36. Show 100-year storm elevation of detention basin and ponding from 100-year storm at all sump intakes. Indicate and illustrate the 100-year elevations on the grading plan as well. Engineers Response: 37. Provide a berm 3 feet in height along both SE Olson Drive and SE Alice’s Road. 38. The driveway needs to drain onto the site from the ROW. Verify that intake along SE Olson Drive has enough capacity to intercept undetained flows from site. Engineers Response: 39. Provide clay water spots on all FES. 40. Provide the total area of disturbance for this project. 41. Update Pollution Prevention Notes C.h. to meet the requirements for topsoil respread to meet SUDAS Specifications Section 2010. SHEET 5 | EROSION AND SEDIMENT CONTROL PLAN 42. Provide a label and show the final discharge point(s) for this site. 43. Provide the mix type proposed for seeding, fertilizing and mulching. SHEET 6 | LANDSCAPE PLAN 44. Add a note to this sheet indicating that planting substitutions shall be approved in writing by the Waukee Development Services Department. 45. Construction note 2, sod all disturbed areas onsite, seeding of detention areas is acceptable. SHEET 7 | MISCELLANEOUS DETAILS 46. Update Fire Hydrant Assembly detail to match City of Waukee Hydrant Detail, STD DWG NO. 34 REV. 1 47. Add City of Waukee FES Footing Detail, STD DWG NO. 30 48. Provide the Type A driveway detail on this sheet. 49. Provide sidewalk ramp details on this sheet. BUILDING ELEVATIONS 50. Clarify what side will face SE Alice’s Road. Please provide separate elevations for both the east and west elevations. Engineers Response: 51. Provide color elevations of the trash enclosure with the next submittal. 52. Provide monument sign details with the next submittal, including dimensions, colors, materials, and lighting details. FIRE DEPARTMENT COMMENTS: 53. Provide proposed fire sprinkler riser room/location. 54. Provide fire department connection location for the fire sprinkler system. 55. Provide fire service where it will separate from domestic including a valve and where it will enter the building and riser location. 56. Provide fire hydrant detail. 57. All buildings shall have a minimum of two fire apparatus accesses. Based on the building occupancy hazard, size, the ability for apparatus to travel around the building, difficulty to provide a second access point, and that the entire building will be equipped with a fire sprinkler system, it will be acceptable to reduce this requirement to the single access as proposed. (City of Waukee Municipal Code Chapter 222 Apendix D(L) amend section of IFC 2009 D104.1 Access). This is as proposed now and this can change if the ability to provide secondary access is available or if the occupancy classification changes. VEENSTRA & KIMM COMMENTS: 58. Drainage Calculations: Show pre-development and post-development drainage maps including catastrophic storm event routing. MISCELLANEOUS COMMENTS: 59. Provide a copy of the Construction Site SWPPP Review Checklist signed by the SWPP designer. 60. Provide a copy of the IDNR issued General Permit #2 authorization letter. 61. Submit $250 fee for the COSESCO inspections. Staff would request that the revised plans and comment response letter be provided in digital form (PDF) and hard copies with 7 full-sized sets of plans delivered to Waukee City Hall. The PDF copy may be emailed. Should you have any questions or concerns regarding these comments, please feel free to contact Brad Deets (515-978-7899), Andy Kass (515-978-7897) or myself at (515) 978-7898. Sincerely, Melissa DeBoer, AICP Planner II BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= AWSV:\Projects\2017\117.0086.01\CADD\SP_1170086_01tsh.dgn2/20/20171:37:40 PMSnyder1:1Y:\pen\date.tblY:\print_drivers\Black_Gray\V8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.AUTUMN RIDGE PLAT 1, LOT 1WAUKEE, IA1170086 9KMMBKCAWS01/24/17117008691REVISED PER CITY COMMENTS02/07/17AWS2REVISED PER CITY COMMENTS02/21/17AWSTITLE SHEET1 11'AUTUMN RIDGE PLAT 1, LOT 1 VICINITY MAP PROJECT LOCATION INDEX OF SHEETS 27 ( WAUKEE CORPORATE LIMITS )(WAUKEE / WEST DESMOINES CORPORATE LIMITS) PARK RD SUNRISE DR VENTURE DR WARRIOR LNASHWORTH DRWACO PLDR BOOTH AVE FLORENCE DRINDIGO LNMELROSE DR WARRIOR LNWINDFIELD PKWY PRIMROSELNCAREFREELNLAUREL ST OLSON DR MAPLELEAF LNOAKLEAF LNPLUMWOOD LNBIRCHWOOD CIR DR MELROSEDR GLENDALE DR W INFIELD DRNDOGWOODLCT CRABAPPLE DRLAUREL DR EERTHCAEPDRASHWORTH DRROSEWOOD DRALICE'S RDROSENKRANZ DR PRAIRIE PARK LN SE ASHTON CTSE CAREFREE LNSE WHITETAIL LNCIRSE HUMMINGBIRD SE BOBWHITE LNSE OLSON DR CT ROSEWOOD OLS ON DRBRIC K DRSE BELL DR DRNE MEADOWLARK LNNE WHITETAIL LNNE CAREFREE LNNE CARDINALLNN WARRIOR LNSE FINCHCIRSE DEERFIELDCYPRESSCTBOONE DRBOONE DRSE CARDINAL LNLNWESTGATE DRSE BLUEGRASSSECIRMAPLELEAFLNHICKORY CIR CIRHAWTHORNERIDGESESEPT BLVDDRWESTBROOK DR REDBUD SE WOOD CREEK DR SE PARKVIEWSEHARPERDRSEWILLOWBR OOKDRSEPARKERDR SEMURPHYDRLN LEGACYHARVESTGOLDEN SEHERITAG EDR HAWTHORNERIDGEDRSEBRIST O LDR SEGREENBR IAR CIR SE TRADENDR APPLEWOODLNASHLEAF (WAUKEE CORPORATE LIMITS) R D E E R T Y A B E S DRSE GREENTREE DRLINDENDRSECIRSESAGEWOOD SE HOLI DAYESTRCCIRSE SILVER PTSE WADDELL WAYSE BOOTH AVE AIDAN ST SE OXFORDR D D O O W L E Z A H E SRIOR LNSE WACOPL96TH ST94TH ST3DRNWBOSTON PKWY SHERIDAN AVE 162NWNDSTNW161STSTNW160THSTNW159THSTNW158THSTNW157THSTSHERIDAN AVE HOLCOMB 161STNWSTSHERIDAN AVE PKWY ST159THHAWTHORN CIR ROSEWOOD CT NW159THSTHAWTHORNDRNW 156TH STST157THNWST158THNWNWNW 155THCTWILDWOOWILDWOOD ROSENW155THSTRIDGE BISHOP DR 92ND STGREENSPIRE DR 94TH STLAKE DR 93RDCT92ND PLGOLFKINGMAN DR93RDCTLAKE DR 94TH STSE BELLCTSE TRADENCTUNIVERSITY AVE SE MADRONE LN SE STONE RIDGE DR SE LA GRANT PARKWAYSE MEADOWLARK FAI RVI EW DR94TH STBERKSHIRE PKWYCROSSINGCREEKPRAIRIE SE KELERMAN LN LDR SE PRAIRIE PARK LN DRSE WATERSEDGECEDARWOOD DR DRFI REN O RT H 35 34 CT SE LAUREL ST PLEASANT VIEW DR DR WESTGATENEHICKMAN RDNE DARTMOOR DRDR G R A C EW O O D NE AVE SE FRONTIER SCALE: 1"=1000' STATE OF IOWA PROFESSIO N ALLANDSCAPE AR CHITECTDate License Number Pages or sheets covered by this seal: 540 NO. ARCHITECT LANDSCAPE under the laws of the State of Iowa. Professional Landscape Architect charge. I am a duly licensed direct supervision and responsible below was prepared by me or under my this technical submission described I hereby certify that the portion of June 30, 2018 License Expires: 540 BALVANZ BRET J. Bret J. Balvanz, PLA Sheet 7 ANKENY, IA 50023 2785 N ANKENY BLVD SUITE 22 C/O KIMBERLEY DEVELOPMENT CORPORATION CENTENNIAL DEVELOPMENT, LC. DEVELOPER OWNER 515-223-5582 MARK GOLDNER ANKENY, IA 50023 3108 NW 89TH AVENUE MJG DEVELOPMENT, LLC. 6 DALLAS COUNTY, IOWA CITY OF WAUKEE 595 SE ALICE'S ROAD FOR SITE PLAN 9. 8. 7. 6. 5. 4. 3. 2. 1. SIDEWALK RAMP DETAILS MISCELLANEOUS DETAILS PLANTING PLAN EROSION AND SEDIMENT CONTROL PLAN GRADE PLAN UTILITY PLAN DIMENSION PLAN PROJECT INFORMATION TITLE SHEET PROJECT MANAGER Date IOWALICENSEDPROFESSIO N A LEN GI NEERLicense Number Pages or sheets covered by this seal: My License Renewal Date is December 31, 2017 16007 under the laws of the State of Iowa. licensed Professional Engineer supervision and that I am a duly by me or under my direct personal engineering document was prepared I hereby certify that this 16007 DEVORE CHAD D.Chad D. DeVore, P.E. Sheets 1-6, 8 & 9 515-964-2020 ANKENY, IOWA 50023 2727 SNYDER BLVD SNYDER & ASSOCIATES, INC. BRENT CULP BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= AWSV:\Projects\2017\117.0086.01\CADD\SP_1170086_02nts.dgn2/20/20171:37:41 PMSnyder1:1Y:\pen\date.tblY:\print_drivers\Black_Gray\V8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.AUTUMN RIDGE PLAT 1, LOT 1WAUKEE, IA1170086 9KMMBKCAWS01/24/17117008691REVISED PER CITY COMMENTS02/07/17AWS2REVISED PER CITY COMMENTS02/21/17AWSPROJECT INFORMATION2 2ZONING GENERAL USE PARKING REQUIREMENTS: 93 93.0 93 C OC FO E OE 4" G 4" HPG 8" W 8" S 12" ST12" ST G G AST UST Features Existing Proposed G EB W LEGEND 8" W(*) 8" S(*) 4" G(*) 4" HPG(*) C(*) OC(*) FO(*) E(*) OE(*) DUCT(*) 93.0 1 Soil Boring Mailbox Satellite Dish Sign Above Ground Storage Tank Underground Storage Tank Fence Post or Guard Post Gas Apparatus Gas Manhole Gas Valve Fiber Optic Handhole Fiber Optic Manhole Communication Handhole Communication Manhole Communication Pedestal Traffic Sign Electric Transformer Electric Box Yard Light Street Light Utility Pole with Transformer Utility Pole with Light Guy Anchor Utility Pole Well Water Service Valve Water Main Valve Fire Hydrant on Building Fire Hydrant Double Storm Sewer Intake Single Storm Sewer Intake Storm Manhole Storm Sewer with Size Sanitary Manhole (*) Denotes the survey quality service level for utilities Test Hole Location for SUE w/ID Duct Bank Sanitary Sewer with Size Water Main with Size High Pressure Gas Main with Size Gas Main with Size Overhead Electric Underground Electric Fiber Optic Overhead Communication Communication Coniferous Tree or Shrub Deciduous Tree or Shrub Tree Stump Tree Line Fence (Silt) Fence (Wood) Fence (Chain Link) Fence (Barbed, Field, Hog) Contour Elevation Spot Elevation UTILITY WARNING UTILITY QUALITY SERVICE LEVELS THE TYPE, SIZE, CONDITION, MATERIAL, AND OTHER CHARACTERISTICS. BY ACTUAL EXPOSURE OR VERIFICATION OF PREVIOUSLY EXPOSED SUBSURFACE UTILITIES, AS WELL AS IS HORIZONTAL AND VERTICAL POSITION OF UNDERGROUND UTILITIES OBTAINEDQUALITY LEVEL (A) SUBSURFACE UTILITIES. GEOPHYSICAL METHODS TO DETERMINE THE EXISTENCE AND APPROXIMATE HORIZONTAL POSITION OF INFORMATION IS OBTAINED THROUGH THE APPLICATION OF APPROPRIATE SURFACE QUALITY LEVEL (B) QUALITY D INFORMATION. UTILITY FEATURES AND USING PROFESSIONAL JUDGMENT IN CORRELATING THIS INFORMATION WITH INFORMATION IS OBTAINED BY SURVEYING AND PLOTTING VISIBLE ABOVE-GROUND QUALITY LEVEL (C) INFORMATION IS DERIVED FROM EXISTING UTILITY RECORDS OR ORAL RECOLLECTIONS.QUALITY LEVEL (D) APPLICABLE, SIZE. THE QUALITY LEVELS ARE BASED ON THE CI / ASCE 38-02 STANDARD. QUALITY LEVELS OF UTILITIES ARE SHOWN IN THE PARENTHESES WITH THE UTILITY TYPE AND WHEN EXCEPT WHERE NOTED AS QUALITY LEVEL A. UTILITIES OR SUBSURFACE FEATURES SHOWN ARE IN THE EXACT LOCATION INDICATED SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE SUBSURFACE FEATURES SHOWN COMPRISE ALL SUCH ITEMS IN THE AREA, EITHER IN RECORDS OBTAINED. THE SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES OR THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR GENERAL NOTES BULK REGULATIONS IMPERVIOUS AREA 48,724 SF 39,549 SF PERVIOUS AREA LEGAL DESCRIPTION 82 SPACES PROVIDED 40 STALLS REQUIRED 2,000/1,000 * 3 = 6 STALLS REQUIRED 3 SPACES PER 1,000 SF OF BUSINESS OFFICE (TENANT) 1,560/1,000 * 2.5 = 4 STALLS REQUIRED 2.5 SPACES PER 1,000 SF OF NON-SERVICE AREA 10 BAYS * 3 = 30 STALLS REQUIRED 3 SPACES PER SERVICE BAY UTILITY CONTACT INFORMATION BENCHMARKS IARTN DERIVED - US SURVEY FEET NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88 - GEOID12A) NAD83(2011)(EPOCH 2010.00) IARTN DERIVED - US SURVEY FEET IOWA STATE PLANE SOUTH COORDINATE SYSTEM CONTROL POINTS CP5 CP4 CP3 CP2 CP1 SOUTHEAST QUADRANT OF SE ALICE'S ROAD & SE OLSON DRIVE. CUT "X" ON BACK OF CURB AT EAST END OF RADIUS AT N=585503.91 E=1543959.89 ALICE'S ROAD & NORTH OF TRAIL, NORTHWEST CORNER OF SITE. CUT "X" ON BACK OF CURB IN CONCRETE AREA INTAKE EAST OF SE N=585937.78 E=1543939.76 LINE WITH NORTH-SOUTH SIDEWALK, NORTHEAST CORNER OF SITE. CUT "X" 1' FROM NORTH EDGE OF HEART OF THE WARRIOR TRAIL IN N=585924.94 E=1544380.01 AT ROAD TAPER, SOUTHEAST CORNER OF SITE. CUT "X" ON BACK OF CURB ON NORTH SIDE OF SE OLSON DRIVE N=585475.98 E=1544318.02 OF SE OLSON DRIVE EAST OF SE ALICE'S ROAD. CUT "X" ON BACK OF CURB BEHIND DOUBLE INTAKE ON NORTH SIDE N=585552.13 E=1544051.17 B2 BM1 SOUTHWEST OF WEST AUTUMN RIDGE APARTMENT BUILDING. BURY BOLT ON HYDRANT ON SOUTH SIDE OF SE OLSON DRIVE ELEV=1050.18 SOUTHWEST OF DOUBLE INTAKE. BURY BOLT ON HYDRANT ON SOUTH SIDE OF SE OLSON DRIVE 20' ELEV=1049.82 C2-COMMUNICATION C1-COMMUNICATION OE-OVERHEAD ELECTRIC E1-ELECTRIC S-SANITARY SEWER W1-WATER FO1-FIBER OPTIC G1-GAS pmay@mediacomcc.com 515-246-2252 PAUL MAY MEDIACOM COMMUNICATIONS raymond.montoya@centurylink.com 515-263-7396 RAY MONTOYA CENTURYLINK jakeislar@midamerican.com 515-252-6472 JAMES KEISLAR MIDAMERICAN ENERGY troyer@waukee.org 515-987-4363 TIM ROYER CITY OF WAUKEE OF WAUKEE PUBLIC WORKS SHALL WITNESS ALL TIE-INS. BB. CONTRACTOR SHALL COORDINATE ALL TIE-IN TO UTILITIES WITH THE CITY OF WAUKEE PUBLIC WORKS DEPARTMENT AND CITY CONCRETE OPERATIONS TO DISCHARGE OFFSITE. AA. CONSTRUCTION OPERATIONS SHALL PROTECT STORM SEWERS AND DRAINAGE WAYS FROM ALLOWING CONCRETE SLURRY FROM PUBLIC IMPROVEMENTS AND ALL UTILITIES SHALL BE TESTED TO CITY STANDARDS. THE CITY SHALL WITNESS ALL TESTING. Z. ALL UTILITIES INCLUDING PRIVATE UTILITIES SHALL BE CONSTRUCTED TO THE CITY OF WAUKEE STANDARD SPECIFICATIONS FOR TO THE DESIGN ENGINEER FOR INCLUSION ON THE RECORD AS-BUILT DRAWINGS. DRAINAGE SWALES, OVERFLOWS, ACCESSIBLE RAMPS AND DETENTION FACILITIES. THE CONTRACTOR SHALL PROVIDE INFORMATION Y. AS-BUILTS SHALL BE PROVIDED TO THE WAUKEE ENGINEERING DEPARTMENT INCLUDING ALL UTILITIES AND AS-BUILT GRADES FOR SEALED. SIDEWALKS AND PCC PAVEMENT. THE PCC RAMP JOINT LOCATED AT THE BACK OF CURB AND ALL EXPANSION JOINTS SHALL BE X. PLACE 3/4" EXPANSION JOINT BETWEEN ALL PCC PAVEMENT/SIDEWALKS AND BUILDINGS. PLACE 1/2" EXPANSION JOINT BETWEEN W. ALL CONSTRUCTION TO EXISTING SANITARY MANHOLES SHALL BE CORE DRILL WITH A LINK SEAL. ALL SANITARY SEWER MANHOLES SHALL BE VACUUM TESTED. WITNESS ALL CLEANING AND TELEVISING. COPIES OF THE REPORT AND VIDEO SHALL BE PROVIDED TO THE CITY OF WAUKEE. V. ALL SANITARY SEWER AND STORM SEWER SHALL BE CLEANED AND TELEVISED PRIOR TO PAVING. THE CITY OF WAUKEE SHALL IN WRITING BY THE CITY OF WAUKEE DEVELOPMENT SERVICES. U. THE CONTRACTOR IS RESPONSIBLE FOR ANY CHANGES MADE DURING CONSTRUCTION THAT HAVE NOT BEEN GRANTED APPROVAL DEVELOPMENT SERVICES PRIOR TO CONSTRUCTION. T. ANY CHANGES PROPOSED TO THE DRAWINGS DURING CONSTRUCTION SHALL BE APPROVED IN WRITING BY THE CITY OF WAUKEE FACILITIES. S. ALL STAKING SHALL BE DONE UNDER THE DIRECTION OF A LICENSED ENGINEER OR LAND SURVEYOR INCLUDING PEDESTRIAN CONSTRUCTION ACTIVITIES BEGINNING. R. A PRE-CONSTRUCTION MEETING WITH THE CITY OF WAUKEE WILL BE REQUIRED A MINIMUM OF ONE WEEK PRIOR TO TO THE STORM SEWER IS AT LEAST TEN FEET. GASKET JOINTS SHALL BE INSTALLED ON EACH SIDE OF THE CROSSING UNTIL THE NORMAL DISTANCE FROM THE WATER MAIN SHALL BE CONSTRUCTED OF REINFORCED CONCRETE WITH A FLEXIBLE O-RING GASKET RATED AT 13 PSI OR GREATER. O-RING Q. IF STORM SEWER CROSSES ABOVE WATER MAIN OR CROSSES LESS THAN 18" BELOW A WATER MAIN THEN STORM SEWER UTILITY SERVICE PROVIDER, CITY OF WAUKEE, AND THE OWNER PRIOR TO CONSTRUCTION. P. CONTRACTOR TO COORDINATE NATURAL GAS, ELECTRICAL, TELEPHONE AND ANY OTHER FRANCHISE UTILITY SERVICES WITH PERMIT IS REQUIRED FOR THIS PROJECT. OF CONSTRUCTION. GRADING AND SOIL EROSION CONTROL CODE REQUIREMENTS SHALL BE MET BY CONTRACTOR. A COSESCO CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR MAINTAINING ANY EXISTING EROSION CONTROL MEASURES ON SITE AT THE TIME O. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING EROSION AND SEDIMENT CONTROL MEASURES AS NECESSARY. N. THE ADJUSTMENT OF ANY EXISTING UTILITY APPURTENANCES TO FINAL GRADE IS CONSIDERED INCIDENTAL TO THE SITE WORK. CAUSED BY CONSTRUCTION ACTIVITIES AT THE END OF EACH WORK DAY AND PRIOR TO A RAIN EVENT. M. THE CONTRACTOR IS RESPONSIBLE FOR CLEANING DIRT AND DEBRIS FROM NEIGHBORING STREETS, DRIVEWAYS, AND SIDEWALKS UNLESS OTHERWISE NOTED. L. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS SHOWN ARE FINISHED GRADES AND/OR TOP OF PAVING SLAB (GUTTER), TO FINISH GRADES. K. CONTRACTOR TO STRIP AND STOCKPILE TOPSOIL FROM ALL AREAS TO BE CUT OR FILLED. RESPREAD TO MINIMUM 8" DEPTH PROJECT TO AN APPROVED OFF-SITE WASTE SITE. J. CONTRACTOR TO LOAD AND TRANSPORT ALL MATERIALS CONSIDERED TO BE UNDESIRABLE TO BE INCORPORATED INTO THE ORDER TO MEET THE CITY OF WAUKEE STANDARDS. FOR APPROVAL OF ANY CHANGES AND THAT ANY CHANGES COMPLETED WITHOUT APPROVAL ARE SUBJECT TO REMOVAL IN BE RESPONSIBLE FOR LAYOUT VERIFICATION OF ALL SITE IMPROVEMENTS PRIOR TO CONSTRUCTION. CONTACT CITY OF WAUKEE CONDITIONS ARE TO BE REPORTED TO THE ARCHITECT/ENGINEER PRIOR TO STARTING CONSTRUCTION. THE CONTRACTOR SHALL DESIGN. DEVIATIONS MAY BE NECESSARY IN THE FIELD. ANY SUCH CHANGES OR CONFLICTS BETWEEN THIS PLAN AND FIELD I. DIMENSIONS, BUILDING LOCATION, UTILITIES AND GRADING OF THIS SITE ARE BASED ON AVAILABLE INFORMATION AT THE TIME OF THE AS-BUILT DOCUMENTS. H. ALL FIELD TILES ENCOUNTERED DURING CONSTRUCTION SHALL BE RECONNECTED OR REPAIRED AND NOTED ACCORDINGLY ON GOVERN. G. IN THE EVENT OF A DISCREPANCY BETWEEN THE QUANTITY ESTIMATES AND THE DETAILED PLANS, THE DETAILED PLANS SHALL MAXIMUM DENSITY. F. CONSTRUCT MANHOLES AND APPURTENANCES AS WORK PROGRESSES. BACKFILL WITH SUITABLE MATERIAL AND COMPACT TO 95% THE CITY OF WAUKEE ENGINEERING DEPARTMENT AT LEAST 48 HOURS PRIOR TO ANY PLANNED WEEKEND OR HOLIDAY WORK. E. NOTIFY OWNER, ENGINEER, CITY OF WAUKEE AT LEAST 48 HOURS PRIOR TO BEGINNING WORK. CONTRACTOR SHALL ALSO NOTIFY NOTIFY THE CITY OF WAUKEE AT LEAST ONE WEEK PRIOR TO ANY ANTICIPATED LANE CLOSURE. BE PROVIDED. FLAGGERS SHALL CONFORM TO THE MUTCD IN APPEARANCE, EQUIPMENT AND ACTIONS. THE CONTRACTOR SHALL TRAFFIC CONTROL DEVICES (MUTCD). WHEN CONSTRUCTION ACTIVITIES OBSTRUCT PORTIONS OF THE ROADWAY, FLAGGERS SHALL D. ALL TRAFFIC CONTROL SHALL BE PROVIDED IN ACCORDANCE WITH REQUIREMENTS SET FORTH IN THE MANUAL ON UNIFORM C. LENGTH OF UTILITIES SHOWN ON PLANS ARE DIMENSIONED FROM CENTERLINE OF STRUCTURE TO CENTERLINE OF STRUCTURE. PUBLIC IMPROVEMENTS, STATEWIDE URBAN DESIGN AND SPECIFICATIONS AND THE SOILS REPORTS PREPARED BY OTHERS. B. CONSTRUCTION OF ALL STREET AND UTILITY IMPROVEMENTS SHALL CONFORM TO THE WAUKEE STANDARD SPECIFICATIONS FOR AT THE CONTRACTOR'S EXPENSE. TO UTILITY ITEMS NOT SHOWN FOR REMOVAL OR MODIFICATION SHALL BE REPAIRED TO THE UTILITY OWNER'S SPECIFICATIONS OF ALL UTILITIES. PROTECT ALL UTILITY LINES AND STRUCTURES NOT SHOWN FOR REMOVAL OR MODIFICATION. ANY DAMAGES NECESSARY DURING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXISTENCE, EXACT LOCATION, AND DEPTH A. NOTIFY UTILITY PROVIDERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES AND COORDINATE WITH UTILITY PROVIDERS AS BEING AN OFFICIAL PLAT, DALLAS COUNTY, IOWA. LOT 1 AUTUMN RIDGE PLAT 1, AUTOMOTIVE REPAIR AND GENERAL OFFICE SQUARE FEET BUILDING AREA = NO SINGLE BUILDING SHALL EXCEED 50,000 MAXIMUM STORIES = 3 MAXIMUM BUILDING HEIGHT = 40 FEET REAR YARD = 30 FEET ADJACENT TO AN R DISTRICT SIDE YARD = NO MINIMUM, EXCEPT 15 FEET MINIMUM WHEN MEASURED FROM TEH PROPOSED ROW LINE. STREET PLAN. THE FRONT YARD SHALL BE THOROUGHFARE SHOWN ON THE OFFICIAL MAJOR FRONT YARD = 30 FEET WHEN FRONTING THE ROW OF A MAJOR MINIMUM LOT WIDTH = NO MINIMUM MINIMUM LOT AREA = NO MINIMUM C-1 (COMMUNITY AND HIGHWAY SERVICE COMMERCIAL DISTRICT) BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= AWSV:\Projects\2017\117.0086.01\CADD\SP_1170086_03dim.dgn2/20/20171:37:45 PMSnyder1:20Y:\pen\date.tblY:\print_drivers\Black_Gray\V8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.AUTUMN RIDGE PLAT 1, LOT 1WAUKEE, IA1170086 9KMMBKCAWS01/24/17117008691REVISED PER CITY COMMENTS02/07/17AWS2REVISED PER CITY COMMENTS02/21/17AWSOFFICE AUTO SERVICE CAR-X TENANT 2,000 SF1,560 SF 5,050 SF FFE=1052.50 LOT 1 AUTUMN RIDGE PLAT 1 6" S8" WH T 18" ST1 5" S T24" ST12" ST10" ST10" ST 12" ST 15" ST10" ST10" ST Concrete Sidewalk18" RCP18" RCP15" RCP24" RCP24" RCP 3 6 " R C P 42" RCP 15" RCP E F.E.S.=1046.39 15" RCP W F.E.S.=1046.74 Concrete Sidewalk15" RCPConcret eG C ICV O 15" RCP 24" RCPGravelConcrete F.L.=1044.34 15" RCP NNE F.L.=1044.29 24" RCP NW&SE Rim=1049.44 F.L.=1043.63 24" RCP WNW&SE Rim=1048.33 15" RCP S 18" RCP N (Unable to Open) Double Intake=1047.40 18" RCP S F.E.S.=1042.94 Inv=1040.64 8" PVC N&S Rim=1046.39 F.L.=1042.47 18" RCP N&SSE F.L.=1042.17 36" RCP SE F.L.=1042.12 42" RCP W Rim=1047.82 18" RCP Pipe S (Unable to Locate Invert) F.L.=1042.89 24" RCP SE F.L.=1042.84 24" RCP N F.L.=1042.64 36" RCP NW (Unable to Open) Double Intake=1046.94 Rim=1047.74 Pipe Stub, No Hydrant MECH ROOM SPRINKLER FDC SAND/OIL SEPARATOR 0 SCALE (FEET) 20 3 320'DIMENSION PLAN CONSTRUCTION NOTESALICE'S ROADS E O L S O N D R IV E30' Building Setback Line30' B uil di ng Set back Li ne17.0'27.0' 4.0'4.0' 6.0'17.0'25.0'17.0'30.5'17.0'52.0'43.0'17.0'25.0'4.0'26.3'10.7'18.0'9.5'9.0'10.0'25.0'25.0'17.0'6.0'4.0'13.0'25.0' 25.0'R 25.0' R 17.0' R 50.0' R 5 .0 'R 15.0'R 5.0'R5 .0'R10.0'R5.0'R 20.0'R5.0'R5.0'R 10.1'3.5'R1A 1B 1B 1B 1B 1B 1B 1B 2A 2A 3A 3A 3A 3A 3A 3B 3B 3B 3B INTEGRAL SIDEWALK AND CURB DETAIL Sidewalk 4" min. 6" Adjacent pavement 18"12" 2% max.1" radius Sealed 'E' joint 6" STANDARD CURB 3 1 3 2 3 3 3C3C 3C 3C 3C 3C 3C 3C 3C 3C 3D 3D 3E 3E 3E 3E 3E 3E 3F 3G 3H 4A 4A 4A 4A 4B 4B 4B 4B 4C 4C 4D 5A 5A 5A 5A 5B 6B 7A 3J TYP. TYP.TYP.5.0'6"3' MIN. 6"6" FOR PAVEMENT CONCRETE AS SPECIFIED EXCEPT SUBGRADE DEPTH 6" SPECIFIED FOR PAVEMENT COMPACTED SUBGRADE AS REBAR @ 12" O.C. #4 EPOXY COATED 8"CONCRETE FLUME DETAIL CITY OF WAUKEE STD. DWG. NO. 31 DIMENSION PLAN1/2" 1/2"7 3" 2"R 1"R 6"t6" CURB 4 CITY OF WAUKEE STD. DWG. NO. 23 NOTE 1. t = PAVEMENT THICKNESS IN INCHES; AS SPECIFIED.10.0'R7B (BK 2004, PG 16175) Flowage Easement Sewer and Overland Existing 80' X 30' Storm (BK 2004, PG 16174) Sewer Easement Existing 25' Sanitary (BK 2004, PG 16172) Utility Easement Existing 10' Public (BK 2004, PG 16177) Flowage Easement Existing 30' Overland (BK 2015, PG 9105) Utility Easement Existing 10' Public (BK 2015, PG 9105) Utility Easement Existing 10' Public (BK 2015, PG 9105) Easement Existing 30' Buffer 149.8'61.1'(BK 2016, PG 25987) Storm Sewer Easement (BK 2016, PG 25987) Storm Sewer Easement (BK 2016, PG 25988) Temporary Construction Easement B. 625 GALLON SAND AND OIL INTERCEPTOR. SEE MECHANICAL PLANS FOR DETAILS. A. TRASH ENCLOSURE. SEE ARCHITECTURAL PLAN FOR DETAIL. 7. SITE AMENITIES, PROVIDE THE FOLLOWING: WITH THE OWNER ALL ASPECTS SITE LIGHTING PRIOR TO CONSTRUCTION. B. SITE LIGHTING SHOWN IS FOR ILLUSTRATION PURPOSES ONLY. CONTRACTOR TO COORDINATE OF ELECTRICAL SERVICE. A. CONTRACTOR TO COORDINATE WITH THE UTILITY OWNER AND PROPERTY OWNER ALL ASPECTS 6. SITE LIGHTING, PROVIDE THE FOLLOWING: B. MONUMENT SIGN. SEE ARCHITECTURAL PLANS FOR DETAIL. A. PROVIDE VAN ACCESSIBLE PARKING SIGNAGE AS PER ADAAG REQUIREMENTS. 5. SIGNS, PROVIDE THE FOLLOWING: D. 45° STRIPING AT 3' ON CENTER SPACING WHERE SHOWN. C. ACCESSIBLE AISLE. 45° STRIPING AT 3' ON CENTER SPACING WHERE SHOWN. B. PAINTED STATE OF IOWA APPROVED ACCESSIBLE PARKING SYMBOL. A. 4" WIDE PAINTED PARKING STALL LINES. 4. PAVEMENT MARKINGS, PROVIDE THE FOLLOWING: J. PCC DRIVE, 9" DEPTH PAVEMENT. H. TRANSFORMER PAD. SPECIFICATIONS. SEE DETAIL SHEET 8. G. ENTRANCE APPROACH TO BE CONSTRUCTED AS TYPE A DRIVEWAY AS PER STANDARD F. CONCRETE FLUME. SEE DETAIL, THIS SHEET. WARNINGS WHERE SHOWN ON PLAN. PEDESTRIAN RAMP WITH A MAXIMUM SLOPE OF 8.33%. PROVIDE DETECTABLE E. D. 6" INTEGRAL CURB AND GUTTER. SEE DETAIL, THIS SHEET. C. 6" PCC CURB. SEE DETAIL, THIS SHEET. B. PCC SIDEWALKS, 4" DEPTH PAVEMENT. A. PCC DRIVES AND PARKING, 6" DEPTH PAVEMENT. 3. PAVEMENTS, PROVIDE THE FOLLOWING: A. CURBING. 2. DEMOLITION, REMOVE THE FOLLOWING: B. PROTECT EXISTING UTILITIES. A. PAVEMENTS TO REMAIN. 1. EXISTING FEATURES, PROTECT THE FOLLOWING: BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= AWSV:\Projects\2017\117.0086.01\CADD\SP_1170086_04utl.dgn2/20/20171:37:46 PMSnyder1:20Y:\pen\date.tblY:\print_drivers\Black_Gray\V8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.AUTUMN RIDGE PLAT 1, LOT 1WAUKEE, IA1170086 9KMMBKCAWS01/24/17117008691REVISED PER CITY COMMENTS02/07/17AWS2REVISED PER CITY COMMENTS02/21/17AWSOFFICE AUTO SERVICE CAR-X TENANT 2,000 SF1,560 SF 5,050 SF FFE=1052.50 LOT 1 AUTUMN RIDGE PLAT 1 8" WH T G G Concrete Sidewalk18" RCP18" RCP15" RCP24" RCP24" RCP 3 6 " R C P 42" RCP 15" RCP E F.E.S.=1046.39 15" RCP W F.E.S.=1046.74 Concrete Sidewalk15" RCPConcret eG C ICV O 15" RCP 24" RCPGravelConcrete F.L.=1044.34 15" RCP NNE F.L.=1044.29 24" RCP NW&SE Rim=1049.44 F.L.=1043.63 24" RCP WNW&SE Rim=1048.33 15" RCP S 18" RCP N (Unable to Open) Double Intake=1047.40 18" RCP S F.E.S.=1042.94 Inv=1040.64 8" PVC N&S Rim=1046.39 F.L.=1042.47 18" RCP N&SSE F.L.=1042.17 36" RCP SE F.L.=1042.12 42" RCP W Rim=1047.82 18" RCP Pipe S (Unable to Locate Invert) F.L.=1042.89 24" RCP SE F.L.=1042.84 24" RCP N F.L.=1042.64 36" RCP NW (Unable to Open) Double Intake=1046.94 Rim=1047.74 Pipe Stub, No Hydrant MECH ROOM SPRINKLER FDC SAND/OIL SEPARATOR 0 SCALE (FEET) 20 4 420'ALICE'S ROADS E O L S O N D R IV E30' Building Setback Line30' B uil di ng Set back Li ne1A 1A 1A 1A 1A 2A 2B 2C 3A 3B 4B OUT E=1047.46 RIM=1052.35 STORM CLEANOUT 110 LF OF 10" ST @ 1.0% 9 8 LF OF 1 5" ST @ 0.4 0 %53 LF OF 10" ST @ 2.0%90 LF OF 15" ST @ 0.40%80 LF OF 12" ST @ 0.50% 78 LF OF 10" ST @ 0.50%99 LF OF 10" ST @ 0.40%@ 0.40%12" ST 22 LF OF 24 LF OF @ 0.40%18" ST OUT N=1044.70 IN SE=1044.90 IN S=1045.20 TC=1051.06 TYPE SW-503 ST-6 INTAKE OUT N=1045.75 IN SW=1045.95 TC=1051.10 TYPE SW-501 ST-3 INTAKE OUT N=1045.29 IN SW=1045.39 TC=1051.05 TYPE SW-501 ST-4 INTAKE OUT NE=1046.35 IN W=1046.55 TC=1051.10 TYPE SW-501 ST-2 INTAKE OUT E=1046.94 TC=1051.20 TYPE SW-501 ST-1 INTAKE INV=1042.84 CONNECT TO EXISTING INTAKE REMOVE EXST. 24" STORM STUB 240 LF OF 24" RCP @ 0.40%OUT N=1046.39 RIM=1050.40 TYPE SW-511 ST-7 INTAKE OUT N=1043.99 IN S=1045.99 TC=1050.60 TYPE SW-501 ST-8 INTAKE TYP. OUT N=1046.26 IN W=1046.36 RIM=1052.35 TYPE SW-401 ST-5 MANHOLE UTILITY PLAN CONSTRUCTION NOTES UTILITY PLANROOM SPRINKLER 2E 2I 2G 2F 2G 2H 2H 2D WATER SERVICE CONNECTION DETAIL 3C 3D 5A 5A5A 6A 2D (BK 2016, PG 25987) Storm Sewer Easement (BK 2004, PG 16174) Sewer Easement Existing 25' Sanitary (BK 2004, PG 16177) Flowage Easement Existing 30' Overland (BK 2016, PG 25988) Temporary Construction Easement (BK 2004, PG 16172) Utility Easement Existing 10' Public (BK 2004, PG 16175) Flowage Easement Sewer and Overland Existing 80' X 30' Storm (BK 2016, PG 25987) Storm Sewer Easement (BK 2015, PG 9105) Utility Easement Existing 10' Public (BK 2015, PG 9105) Utility Easement Existing 10' Public (BK 2015, PG 9105) Easement Existing 30' Buffer 1 5 0' HYDRANT COVE RAGE Inv.=1040.64 Sewer @ 1.0%133 LF of 6" SanitaryInv.=1043.3 Rim=1052.25 (VERIFY PRIOR TO CONSTRUCTION) TP=1041.06(WAT) BP=1046.63(STM) TP=1045.60(STM) BP=1047.15(SAN) INV= 1044.60 W/ CLAY WATER STOP 18" CMP APRON ST-6A INV=1043.90 W/ CLAY WATER STOP 12" CMP APRON ST-8A INV=1043.80 CLAY WATER STOP APRON GUARD, & 24" FES W/FOOTING , ST-9 NECESSARY USE 1:1 RISER AS INV=1046.11 9 9 8 This Sheet See Detail SEPARATION. 9. CRITICAL CROSSING. CONTRACTOR TO VERIFY ALL CROSSINGS AND PROVIDE 18" MINIMUM CLEARANCE, 3-FEET OF CLEARANCE IS TO BE PROVIDED ON THE OTHER SIDES. 8. THE TRANSFORMER WILL OPEN TO THE NORTH OR EAST AND REQUIRE A MINIMUM OF 10-FEET OF ARCHITECTURAL AND MECHANICAL PLANS FOR DETAIL. 7. MECHANICAL EQUIPMENT IS LOCATED ON THE ROOF, CONCEALED BEHIND THE PARAPET. SEE A. CONNECT TO GAS METER. COORDINATE WITH UTILITY COMPANY AND MECHANICAL PLANS. 6. GAS MAIN; PROVIDE THE FOLLOWING: A. DOWNSPOUT CONNECTION LINE. SEE DETAIL SHEET 8. 5. STORM SEWER; PROVIDE THE FOLLOWING: WITH THE OWNER ALL ASPECTS SITE LIGHTING PRIOR TO CONSTRUCTION. B. SITE LIGHTING SHOWN IS FOR ILLUSTRATION PURPOSES ONLY. CONTRACTOR TO COORDINATE OF ELECTRICAL SERVICE. A. CONTRACTOR TO COORDINATE WITH THE UTILITY OWNER AND PROPERTY OWNER ALL ASPECTS 4. SITE LIGHTING, PROVIDE THE FOLLOWING: MECHANICAL PLANS PRIOR TO CONSTRUCTION. D. CONNECT TO BUILDING SANITARY SEWER SERVICE. VERIFY LOCATION AND ELEVATION W/ PSX: DIRECT DRIVE CONNECTOR. VERIFY LOCATION AND ELEVATION PRIOR TO CONSTRUCTION. C. REMOVE EXISTING 8" SANITARY SEWER SERVICE. CONNECT TO MANHOLE USING PRESS SEAL B. SANITARY SEWER CLEANOUT. A. 6" SANITARY SEWER SERVICE LINE AT 1.0% MINIMUM SLOPE. 3. SANITARY SEWER SERVICES; PROVIDE THE FOLLOWING: I. SPRINKLER ROOM. H. 2" WATER VALVE. G. 2" DOMESTIC CONNECTION. F. 8" RW VALVE WITHIN 5' OF THE BUILDING. E. 8" x 8" CROSS W/ REDUCERS EAST AND WEST. D. REMOTE FIRE DEPARTMENT CONNECTION. COORDINATE W/ MECHANICAL PLANS. C. HYDRANT ASSEMBLY. B. 8" WATER SERVICE LINE. A. CONNECT TO EXISTING SERVICE STUB. 2. WATER SERVICES, PROVIDE THE FOLLOWING: A. PROTECT EXISTING UTILITIES. 1. EXISTING FEATURES, PROTECT THE FOLLOWING: BUILDING BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= AWSV:\Projects\2017\117.0086.01\CADD\SP_1170086_05gra.dgn2/20/20171:37:47 PMSnyder1:20Y:\pen\date.tblY:\print_drivers\Black_Gray\V8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.AUTUMN RIDGE PLAT 1, LOT 1WAUKEE, IA1170086 9KMMBKCAWS01/24/17117008691REVISED PER CITY COMMENTS02/07/17AWS2REVISED PER CITY COMMENTS02/21/17AWSOFFICE AUTO SERVICE CAR-X TENANT 2,000 SF1,560 SF 5,050 SF FFE=1052.50 LOT 1 AUTUMN RIDGE PLAT 1 6" S8" WH T 18" ST1 5" S T24" ST12" ST10" ST10" ST 12" ST 15" ST10" ST10" ST 10431044 104410451045104510451045104510451045104510461046104610461046104610461046104610461 0 4 6 104610461046 1046 10461046 1046104710471047104710471047104710 4 7 10471047104710471047104710481048 104810481048104810481048104810481048104810491049104910491049104910491049 10491 0 4 9 1049 10501050105010501050105010501051105110511052105210531053105410541 055Concrete Sidewalk18" RCP18" RCP15" RCP15" RCP 2 4" RCP24" RCP24" RCP 3 6 " R C P 42" RCP 15" RCP E F.E.S.=1046.39 15" RCPConcret eG C ICV O BM1 BM2 CP1 CP5 24" RCPGravelConcrete 15" RCP E F.E.S.=1045.19 15" RCP SSW F.E.S.=1045.04 F.L.=1044.34 15" RCP NNE F.L.=1044.29 24" RCP NW&SE Rim=1049.44 F.L.=1043.63 24" RCP WNW&SE Rim=1048.33 15" RCP S 18" RCP N (Unable to Open) Double Intake=1047.40 18" RCP S F.E.S.=1042.94 Inv=1040.64 8" PVC N&S Rim=1046.39 F.L.=1042.47 18" RCP N&SSE F.L.=1042.17 36" RCP SE F.L.=1042.12 42" RCP W Rim=1047.82 18" RCP Pipe S (Unable to Locate Invert) F.L.=1042.89 24" RCP SE F.L.=1042.84 24" RCP N F.L.=1042.64 36" RCP NW (Unable to Open) Double Intake=1046.94 Rim=1047.74 Pipe Stub, No Hydrant MECH ROOM SPRINKLER FDC SAND/OIL SEPARATOR 1043.801043.90 1044 1044.60 10451045 1045 1045.13 Overflow 1045.70 1046 1046 1046 1046 1046104610461046.70 1046.70 10471047 1048 10481048 (1048.32) (1048.42) 1048.56 1048.57 1048.601048.63 1048.64 (1048.69) 1048.71 (1048.74) 1048.75 1048.82 1048.84 1048.84 1048.86 (1048.87) 1048.90 1048.99 1049 10491049 10491049.06 1049.06 1049.12 10 4 9.18 1049.25 1049.25 1049.31 1049.40 1049.68 1049.70 0.62%1.65%105010501050 10 5 0 5.71%1050.10 LP 1050.30 1050.40 3.74%0.85%1050.50 1050.55 LP 1050.56 LP 1050.60 1050.60 LP 1050.60 LP 1050.70 LP 1.01% 0.86% 1050.75 1050.75 1.05%1050.80 1050.801.11%1.18%1.18%1.85%1.00%1.03%1.18%1050.90 1050.90 1.10% 1050.90 HP 1.00% 1050.95 1.47%1051.00 1051.001051.00 1051 10511051105110511051 10511051 1051 1051 10511051.05 4.00%1051.10 1051.10 1051.10 1051.10 1051.10 0.96% 1051.15 1051.15 1051.20 1051.20 1051.20 1.45%1051.24 1051.25 1051.25 1051.25 HP 1051.25 1051.25 1051.25 HP 1051.30 1051.30 1051.30 1051.30 1051.30 1.04%1051.311.73%1051.351051.35 1051.35 1051.35 1051.371051.373.18% 1051.40 1051.40 0.33% 1051.43 0.95% 1051.451051.451051.45 1.43% 1051.50 1051.50 1051.50 1051.50 HP1.15%1051.55G 1052.05T/C 1051.55 1051.55 1051.55G1052.05T/C 1051.55G 1052.05T/C 1051.58 1.18% 1051.60 1051.60 1051.60 2.80%1051.65 1051.65 1051.66G 1052.15T/C 1051.66 2.45% 1051.75 HP 1051.78 3.11%1051.80 1051.80 1051.84 1051.86 1051.93 1051.99 1051.99 1051.99 1052.00 1052105210521052 10521052.05 1052.15 1052.151052.21 1052.25 1052.25 1052.25 1052.251052.25 2.76%1052.30 1052.31 1052.341052.34 1052.401052.42 1052.42 2.92%1052.50 1052.501052.50 1052.50 1052.50 1052.50 105310540 SCALE (FEET) 20 5 520'ALICE'S ROADSE OLSON DRIVE GRADE PLANPOLLUTION PREVENTION NOTES 5.5%2.0%0.5%2.0% STORMWATER DETENION PRIOR TO FILING OF THE "NOTICE OF DISCONTINUATION". REMOVE ALL TEMPORARY EROSION CONTROL MEASURES AND SITE WASTE k. WASHOUT MUST BE CONTAINED ONSITE. SEDIMENT BASIN OR OTHER CONTROL DEVICE WHERE POSSIBLE. CONCRETE AREAS WITH DIVERSION BERMS AND/OR SILT BARRIERS AND DIRECT TO A AND CONCRETE WASHOUT FACILITY. CONTROL RUNOFF FROM STAGING MAINTENANCE AREA, TEMPORARY SANITARY FACILITIES, MATERIALS STORAGE, SHOULD CONTAIN THE FOLLOWING: JOB TRAILERS, FUELING / VEHICLE RECORD IN THE SWPPP. UNLESS NOTED OTHERWISE, STAGING AREAS COORDINATE LOCATIONS OF STAGING AREAS WITH THE OWNER AND j. CALENDAR DAYS. ACTIVITY HAS FINISHED OR IS PLANNED TO BE DELAYED MORE THAN 21 MEASURES NO LATER THAN 14 CALENDAR DAYS AFTER CONSTRUCTION COMPLETION OR DELAY OF GRADING OPERATIONS. INITIATE STABILIZATION MIX, PERMANENT SEED MIX, OR SOD AS SOON AS PRACTICAL UPON STABILIZE UNDEVELOPED, DISTURBED AREAS WITH MULCH, TEMPORARY SEED i. BUILDINGS OR OTHER IMPROVEMENTS ARE LOCATED. FOUND IN SOD) ON ALL DISTURBED AREAS, EXCEPT WHERE PAVEMENT, RESPREAD A MINIMUM OF 8 INCHES OF TOPSOIL (INCLUDING TOPSOIL h. INSTALLED. OUTLET CONTROL MEASURES AS SOON AS STORM SEWERS ARE PROGRESS TO ENSURE CONTINUOUS RUNOFF CONTROL. PROVIDE INLET AND AREAS REACH THEIR FINAL GRADES AND AS CONSTRUCTION OPERATIONS EROSION CONTROL MATS, MULCH, DITCH CHECKS OR RIPRAP AS SOON AS INSTALL NECESSARY CONTROL MEASURES SUCH AS SILT BARRIERS, g. AND TAKE REMEDIAL ACTIONS FOR FUTURE PREVENTION. SEWERS. REMOVE ANY ACCUMULATION OF EARTH OR DEBRIS IMMEDIATELY STREETS, DRIVEWAYS, SIDEWALKS, DRAINAGEWAYS, OR UNDERGROUND ACTIVITIES ON ADJOINING PUBLIC OR PRIVATE PROPERTIES, INCLUDING PREVENT ACCUMULATION OF EARTH AND DEBRIS FROM CONSTRUCTION f. IMPLEMENT ANY RECOMMENDED MEASURES WITHIN 7 DAYS. OWNER OR ENGINEER DURING CONSTRUCTION. REVISE THE SWPPP AND ACTIONS IN THE SWPPP WITH A COPY SUBMITTED WEEKLY TO THE DAYS. RECORD THE FINDINGS OF THESE INSPECTIONS AND ANY RESULTING PERSONNEL ASSIGNED BY THE CONTRACTOR) EVERY SEVEN CALENDAR INSPECT THE PROJECT AREA AND CONTROL DEVICES (BY QUALIFIED e. ORIGINAL CAPACITY. SILT CONTROL DEVICES WHEN THE MEASURES HAVE LOST 50% OF THEIR SEDIMENT REMOVAL THROUGHOUT THE PERMIT PERIOD. CLEAN OR REPLACE IN WORKING ORDER, INCLUDING CLEANING, REPAIRING, REPLACEMENT, AND MAINTAIN ALL TEMPORARY AND PERMANENT EROSION CONTROL MEASURES d. CONSTRUCTION OPERATIONS AT ANY TIME. CONSTRUCTION AND LIMIT TO A MINIMUM THE TOTAL AREA DISTURBED BY PRESERVE EXISTING VEGETATION IN AREAS NOT NEEDED FOR c. CLEARING AND GRADING OPERATIONS. BASINS DOWNSTREAM OF SOIL DISTURBING ACTIVITIES PRIOR TO SITE SILT BARRIERS, DITCH CHECKS, DIVERSION BERMS, OR SEDIMENTATION INSTALL PERIMETER AND FINAL SEDIMENT CONTROL MEASURES SUCH AS b. WATER INFILTRATION, AND MINIMIZE SOIL COMPACTION. VEGETATED AREAS TO INCREASE SEDIMENT REMOVAL AND MAXIMIZE STORM NATURAL BUFFERS AROUND SURFACE WATERS, DIRECT STORM WATER TO SURFACE WHEN DISCHARGING FROM BASINS, PROVIDE AND MAINTAIN UTILIZE OUTLET STRUCTURES THAT WITHDRAW WATER FROM THE a. FOLLOWING BMP'S UNLESS INFEASIBLE OR NOT APPLICABLE: OF THE GENERAL PERMIT AND SWPPP, INCLUDING, BUT NOT LIMITED TO, THE THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL REQUIREMENTS 4. CONSTRUCTION PROGRESS AND CHANGES AT THE PROJECT SITE. THE SWPPP AND SITE MAP SHOULD BE EXPEDITIOUSLY REVISED TO REFLECT 3. THOSE SHOWN ON THE PLAN MAY BE REQUIRED. CONTRACTOR TO IDENTIFY, NOTE AND IMPLEMENT. ADDITIONAL BMP'S FROM RESULT OF CONSTRUCTION ACTIVITIES ARE THE RESPONSIBILITY OF THE COVERAGE. ALL BMP'S AND EROSION CONTROL MEASURES REQUIRED AS A PRACTICES (BMP) FOR COMPLIANCE WITH THE PROJECT'S NPDES PERMIT THE SWPPP ILLUSTRATES GENERAL MEASURES AND BEST MANAGEMENT 2. THE POLLUTION PREVENTION PLAN MADE DURING CONSTRUCTION. REFER TO THE SWPPP FOR ADDITIONAL REQUIREMENTS AND MODIFICATIONS TO DOCUMENT IN ADDITION TO THESE PLAN DRAWINGS. THE CONTRACTOR SHOULD THE STORM WATER POLLUTION PREVENTION PLAN (SWPPP) IS A SEPARATE 1. POLLUTION PREVENTION PLAN:C. ACCEPTANCE AND/OR SUBMITTAL OF THE NOTICE OF DISCONTINUATION. PROVIDE THE ORIGINAL DOCUMENTS TO THE OWNER UPON PROJECT PROJECT COMPLETION. THE CONTRACTOR SHALL RETAIN A RECORD COPY AND DOCUMENTS MUST BE RETAINED FOR A PERIOD OF THREE YEARS AFTER EROSION CONTROL MEASURES. ALL PLANS, INSPECTION REPORTS, AND OTHER STABILIZATION OF THE DISTURBED SITE AND REMOVAL OF ALL TEMPORARY A "NOTICE OF DISCONTINUATION" MUST BE FILED WITH THE IDNR UPON FINAL 3. OF THE CLEAN WATER ACT AND THE CODE OF IOWA. FAILURE TO COMPLY WITH THE NPDES PERMIT REQUIREMENTS IS A VIOLATION AND MUST BE PRESENTED TO ANY JURISDICTIONAL AGENCIES UPON REQUEST. INSPECTION LOG, AND OTHER ITEMS, SHALL BE KEPT ON SITE AT ALL TIMES PUBLICATIONS, DISCHARGE AUTHORIZATION LETTER, CURRENT SWPPP, SITE INCLUDING, BUT NOT LIMITED TO, THE NOTICE OF INTENT, PROOF OF ALL DOCUMENTS RELATED TO THE STORM WATER DISCHARGE PERMIT, 2. OBTAINING THE GENERAL PERMIT COVERAGE FROM THE IDNR. THE STORM WATER POLLUTION PREVENTION PLAN (SWPPP) AND POSSIBLY OF THE NPDES GENERAL PERMIT NO. 2 INCLUDING CREATING OR MAINTAINING RESPONSIBLE FOR COMPLIANCE WITH AND FULFILLMENT OF ALL REQUIREMENTS (EPA). THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS ARE FROM THE IDNR, AS REQUIRED BY THE ENVIRONMENTAL PROTECTION AGENCY FOR STORM WATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITIES THIS PROJECT REQUIRES COVERAGE UNDER THE NPDES GENERAL PERMIT NO. 2 1. STORM WATER DISCHARGE PERMITB. DEDUCT THE COST THEREOF FROM AMOUNTS DUE TO THE CONTRACTOR. PRIVATE PROPERTY, THE OWNER MAY, BUT NEED NOT, REMOVE SUCH ITEMS AND EARTH SEDIMENTATION OR DEBRIS WHICH COMES ONTO ADJOINING PUBLIC OR CONTRACTOR FAILS TO TAKE NECESSARY STEPS TO PROMPTLY REMOVE INCLUDING REASONABLE ATTORNEY FEES INCURRED TO OWNER. FURTHER, IF THE RESULTING FROM DAMAGES TO ADJOINING PUBLIC OR PRIVATE PROPERTY, ENGINEER HARMLESS FROM ANY AND ALL CLAIMS OF ANY TYPE WHATSOEVER DAMAGE CLAIMS: THE CONTRACTOR WILL HOLD THE OWNER AND ARCHITECT / 2. PERFORMANCE. BORROW OR DEPOSIT AREAS DURING PERFORMANCE OR AS A RESULT OF EROSION AND POLLUTION FROM THIS PROJECT SITE AND ALL OFF-SITE CONTRACTOR SHALL TAKE ALL NECESSARY STEPS TO PROTECT AGAINST PERMIT, THE U.S. CLEAN WATER ACT AND ANY LOCAL ORDINANCES. THE IOWA CODE, THE IOWA DEPARTMENT OF NATURAL RESOURCES (IDNR) NPDES ALL POTENTIAL POLLUTION AND SOIL EROSION CONTROL REQUIREMENTS OF THE CODE COMPLIANCE: THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH 1. POLLUTION PREVENTION AND EROSION PROTECTIONA. 2.26 ACRES TOTAL DISTURBED AREA Path Overflow Elev.=1051.25 100-YR Path Overflow Elev.=1051.25 100-YR Elev.=1050.90 100-YR Path Overflow 100-YR Elev.=1050.60 Path Overflow 100-YR Elev.=1051.06 Path Overflow Elev.=1051.25 100-YR Path Overflow Elev.=1051.25 100-YR BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= AWSV:\Projects\2017\117.0086.01\CADD\SP_1170086_06ero.dgn2/20/20171:37:49 PMSnyder1:20Y:\pen\date.tblY:\print_drivers\Black_Gray\V8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.AUTUMN RIDGE PLAT 1, LOT 1WAUKEE, IA1170086 9KMMBKCAWS01/24/17117008691REVISED PER CITY COMMENTS02/07/17AWS2REVISED PER CITY COMMENTS02/21/17AWSOFFICE AUTO SERVICE CAR-X TENANT 2,000 SF1,560 SF 5,050 SF FFE=1052.50 LOT 1 AUTUMN RIDGE PLAT 1 6" S8" WH T G G 10431044 104410451045104510451045104510451045104510461046104610461046104610461046104610461 0 4 6 104610461046 1046 10461046 1046104710471047104710471047104710 4 7 10471047104710471047104710481048 104810481048104810481048104810481048104810491049104910491049104910491049 10491 0 4 9 1049 10501050105010501050105010501051105110511052105210531053105410541 055Concrete Sidewalk18" RCP18" RCP15" RCP15" RCP 2 4" RCP24" RCP24" RCP 3 6 " R C P 42" RCP 15" RCP E F.E.S.=1046.39 15" RCPConcret eG C ICV O BM1 BM2 CP1 CP5 24" RCPGravelConcrete 15" RCP E F.E.S.=1045.19 15" RCP SSW F.E.S.=1045.04 F.L.=1044.34 15" RCP NNE F.L.=1044.29 24" RCP NW&SE Rim=1049.44 F.L.=1043.63 24" RCP WNW&SE Rim=1048.33 15" RCP S 18" RCP N (Unable to Open) Double Intake=1047.40 18" RCP S F.E.S.=1042.94 Inv=1040.64 8" PVC N&S Rim=1046.39 F.L.=1042.47 18" RCP N&SSE F.L.=1042.17 36" RCP SE F.L.=1042.12 42" RCP W Rim=1047.82 18" RCP Pipe S (Unable to Locate Invert) F.L.=1042.89 24" RCP SE F.L.=1042.84 24" RCP N F.L.=1042.64 36" RCP NW (Unable to Open) Double Intake=1046.94 Rim=1047.74 Pipe Stub, No Hydrant MECH ROOM SPRINKLER FDC SAND/OIL SEPARATOR 1044 10451045 1045 1046 1046 1046 1046 10461046104610471047 1048 10481048 1049 10491049 1049 105010501050 10 5 0 1051 10511051105110511051 10511051 1051 1051 10511052105210521052 1052105310546 620'ALICE'S ROADSE OLSON DRIVE (5'-0" max.) Post Spacing (5'-0" max.) Post Spacing Variable (20'-0" for a normal 10'-0" wide ditch.) TYPICAL SILT FENCE DITCH CHECKForeslope Backslope 1 2" min. 20" min. (600'-0" if slope is flatter than 5%) 200'-0" max. length per section (Plan View) TYPICAL SILT FENCE INSTALLATION ON LONGITUDINAL SLOPES Ground Contours ground contour. Install parallel to individual section of silt fence. Install "J-hook" at each end of an 24" 36" 8'-0" Spacing DETAILS OF SILT FENCE ON LONGITUDINAL SLOPES 1 2 Ground Line Fabric SILT FENCE to adequately support fence. concentration areas, or as required Reduce post spacing to 5'-0" at water folded below the ground line). of 6 inches deep (fabric may be Insert 12 inches of fabric a minimum 2 1 ATTACHMENT TO POST Fabric Post Cable Ties Wire or See plans for spacing. (Profile View) TYPICAL SILT FENCE INSTALLATION ON LONGITUDINAL SLOPES Flow 1 1 4'-0" min. Fence Post 'T' Steel Ground line Fabric EROSION AND SEDIMENT CONTROL PLANBASKET SEDIMENT ENGINEER) (FIELD VERIFY WITH WASHOUT LOCATION APPROX. CONCRETE ENTRANCE/EXIT CONSTRUCTION STABILIZED 0 SCALE (FEET) 20 SEDIMENT BASKET DEVELOPER) FINAL LOCATION WITH (COORDINATE SIZE AND STOCKPILE LOCATION APPROX. TOPSOIL STORMWATER MANAGEMENT QUANTITIES SEDIMENT BASKET SEDIMENT BASKET DEVELOPER) (COORDINATE WITH STAGING AREA SEDIMENT BASKET Q PEAK = 13.20 CFS TO EXISTING STORM DISCHARGE LOCATION 100-YR Elev.=1050.60 100-YR Elev.=1051.06 100-YR Elev.=1045.62 Elev.=1051.25 100-YR Elev.=1051.25 100-YR Elev.=1051.25 100-YR Elev.=1051.25 100-YR Elev.=1050.90 100-YR Path Overflow Path Overflow Path Overflow Path Overflow Path Overflow Path Overflow Path Overflow STORMWATER DETENION 306 SQ.SODDING 0.24 AC.TYPE 1 PERMANENT LAWN MIXTURE 2.26 AC.TYPE 4 SEEDING, FERTILIZING & MULCHING 7 EA.SEDIMENT BASKETS 918 LF.SILT FENCE BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= AWSV:\Projects\2017\117.0086.01\CADD\SP_1170086_07lnd.dgn2/20/20171:37:51 PMSnyder1:20Y:\pen\date.tblY:\print_drivers\Black_Gray\V8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.AUTUMN RIDGE PLAT 1, LOT 1WAUKEE, IA1170086 9KMMBKCAWS01/24/17117008691REVISED PER CITY COMMENTS02/07/17AWS2REVISED PER CITY COMMENTS02/21/17AWS18" RCP18" RCP15" RCP24" RCP24" RCP 3 6" R C P 42" RCP 15" RCP E F.E.S.=1046.39 ICV O BM2 CP1 CP224" RCP15" RCP E F.E.S.=1045.19 15" RCP SSW F.E.S.=1045.04 F.L.=1044.34 15" RCP NNE F.L.=1044.29 24" RCP NW&SE Rim=1049.44 F.L.=1043.63 24" RCP WNW&SE Rim=1048.33 18" RCP S F.E.S.=1042.94 Inv=1040.64 8" PVC N&S Rim=1046.39 F.L.=1042.47 18" RCP N&SSE F.L.=1042.17 36" RCP SE F.L.=1042.12 42" RCP W Rim=1047.82 18" RCP Pipe S (Unable to Locate Invert) F.L.=1042.89 24" RCP SE F.L.=1042.84 24" RCP N F.L.=1042.64 36" RCP NW (Unable to Open) Double Intake=1046.94 Rim=1047.74 Pipe Stub, No Hydrant MECH ROOM SPRINKLER FDC SAND/OIL SEPARATOR 1044 10451045 1045 1046 1046 1046 1046 10461046104610471047 1048 10481048 1049 10491049 1049 105010501050 1 0 5 0 1051 10511051105110511051 10511051 1051 1051 10511052105210521052 1052105310542 2 2 2 4 4 4 4 4 4 4 6 6 6 6 OFFICE AUTO SERVICE CAR-X TENANT 2,000 SF1,560 SF 5,050 SF FFE=1052.50 LOT 1 AUTUMN RIDGE PLAT 1 6" S8" WH T G G 0 SCALE (FEET) 20 7 720'ALICE'S ROADPLANTING PLANSE O LSO N D R IV EPLANTING PLAN GENERAL NOTES PLANTING PLAN CONSTRUCTION NOTES LANDSCAPE REQUIREMENTS DATE OF INSTALLATION. D. CONTRACTOR SHALL GUARANTEE ALL PLANT MATERIAL FOR A PERIOD OF ONE YEAR FROM "AMERICAN STANDARDS FOR NURSERY STOCK" (ANSI Z60.1-LATEST EDITION). C. ALL PLANT MATERIAL SHALL AT LEAST MEET MINIMUM REQUIREMENTS SHOWN IN THE COORDINATE AND COOPERATE WITH UTILITY COMPANIES DURING CONSTRUCTION. CONTRACTOR'S CARELESSNESS SHALL BE CORRECTED AT THE CONTRACTOR'S EXPENSE. AVOID DAMAGE TO UTILITIES AND SERVICES DURING CONSTRUCTION. ANY DAMAGE DUE TO THE RESPONSIBLE FOR DETERMINING EXISTENCE, EXACT LOCATION AND DEPTH OF ALL UTILITIES. B. NOTIFY UTILITY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION. CONTRACTOR IS NOT WARRANT THAT THE UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED. SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEY FURTHER DOES OBTAINED. THE SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES SHOWN COMPRISE ALL THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR RECORDS A. UTILITY WARNING: KEY COMMON NAME SIZE COMMENTSQTY CNTMR BOTANICAL NAME GT AF CNT SHRUBSPLANT SCHEDULE Gledtisia triacanthos var. inermis 'Skyline' BLACKHILLS SPRUCE 6' Ht.B&B Malus 'Royal Raindrops' PO CNT. (5' O.C.)18" Ht. SKYLINE HONEYLOCUST ROYAL RAINDROPS CRABAPPLETREES Physocarpus opulifolius 'Donna May'LITTLE DEVIL NINEBARK CNT. (5' O.C.)18" Ht.CA Calamagrostis x acitoflora 'Karl Foerster'FOERSTER'S FEATHER REED GRASS 8' HT. 8' HT.CNT TO 6' Ht.B&BThuja occidentalis 'Techny' TECHNY ARBORVITAE CO 8' Ht.CNTCeltis occidentalis HACKBERRY 6' Ht.CNTSPRING SNOW CRABAPPLE AG 6' Ht.CNTAmelanchier × grandiflora 'Autumn Brilliance'AUTUMN BRILLIANCE SERVICEBERRY SIENNA GLEN MAPLEAcer x freemanii 'Sienna'13 5 8 3 7 4 4 7 28 17 5-PG 3-PF 1-AG 2-AG 2-CO 3-MR 1-AF 3-AG 8 6' Ht.VANDERWOLF'S LIMBER PINEPinus flexelis 'Vanderwolf's Pyramid'B&B 6' Ht. 3-AF 3-AF 1-MS PF 2-PF 3-PF 2-TO 1-AG Picea glauca 'Densata'PG Malus 'Spring Snow'MS 1-MS 1-CO 1-GT 1-GT 2-GT 1-CO 1-AF 1-AF 1-GT 1-GT 3-SB 1-SB 6-JC 7-CA 1-SB 1-MS 5-TO 1-AF 6-PO 1-GT 1-GT 1-MS 7-CA 2-JV 4-SB 4-SB 6-JV 6-SB 8-CA 1-MS 6-PO 6-JV 5-PO 7-JV 6-CA 6 18" Ht.CNT. (5' O.C.) Juniperus chinensis 'Sea Green'JC JV 21 Juniperus virginiana 'Grey Owl'GREY OWL JUNIPER 18" Ht.CNT. (5' O.C.) SEA GREEN JUNIPER 21 18" Ht.CNT. (5' O.C.)SB Spiraea betulifolia 'Tor'TOR BIRCHLEAF SPIREA HK 10 18" Ht.CNT. (5' O.C.)Hypericum kalmianum 'Ames'KALM'S ST. JOHN'S WORT 8-HK 2-HK 3-AF 1-SB (3' HIGH SHRUBS PROVIDED IN LIEU OF BERM) OPEN SPACE TREE REQUIREMENT). IN ADDITION TO. (6 TREES PROVIDED AND COUNTED TOWARDS IS INCLUDED IN THE OPEN SPACE TREE REQUIREMENT AND NOT THE FRONTAGE CALCULATION IS EXCLUSIVE OF DRIVEWAYS AND (226.76 LF/40 LF = 5.66 TREES REQUIRED) 1 OVERSTORY TREE PER 40 LINEAR FEET OF FRONTAGE. WEST (PUBLIC R.O.W.) --4.86 x 2 = 9.72 ORNAMENTAL TREES REQ'D. (10 PROVIDED) --4.86 x 3 = 14.58 EVERGREEN TREES REQ'D. (15 PROVIDED) --4.86 x 2 = 9.72 OVERSTORY TREES REQ'D. (10 PROVIDED) 243.02 LF/50 LF = 4.86 PU (PER 50 LINEAR FEET OF BUFFER) 2 OVERSTORY, 3 EVERGREEN, 2 ORNAMENTAL 30' BUFFERYARD REQUIRED (243.02 LF): EAST (243.02 L.F. ADJACENT TO R-3 PD, 73.15 L.F. ADJACENT TO OUTLOT 'Z') (3' HIGH SHRUBS PROVIDED IN LIEU OF 3' HIGH BERM) OPEN SPACE TREE REQUIREMENT). IN ADDITION TO. (7 TREES PROVIDED AND COUNTED TOWARDS IS INCLUDED IN THE OPEN SPACE TREE REQUIREMENT AND NOT THE FRONTAGE CALCULATION IS EXCLUSIVE OF DRIVEWAYS AND (265.38 LF/40 LF = 6.63 TREES REQUIRED) 1 OVERSTORY TREE PER 40 LINEAR FEET OF FRONTAGE. SOUTH (PUBLIC R.O.W.) NO BUFFER REQUIRED NORTH (328.07 L.F. ADJACENT TO OUTLOT) BUFFER AND SCREENING REQUIREMENTS: --(17,655 SF/1,000 SF = 17.65 SHRUS (18 PROVIDED) 1 SHRUB PER 1,000 SQUARE FOOT OF REQUIRED OPEN SPACE 25% UNDERSTORY TREES (4 PROVIDED). 25% EVERGREEN TREES (5 PROVIDED). 50% OVERSTORY SHADE TREES (9 PROVIDED). --(17,655 SF/1,000 SF = 17.65 TREES (18 TREES REQUIRED) 1 TREE PER 1,000 SQUARE FOOT OF REQUIRED OPEN SPACE SIDEWALKS) --(CALCULATION OF PROVIDED OPEN SPACE DOES NOT INCLUDE OPEN SPACE PROVIDED: 38,982.36 SQUARE FOOT (44.16%) --(88,273 SQUARE FOOT x 20% = 17,655 SQUARE FOOT) OPEN SPACE REQUIRED: 17,655 SQUARE FOOT TOTAL LOT AREA: 88,273 SQUARE FOOT (2.02 ACRES) C-1 ZONING: 20% OPEN SPACE REQUIRED OPEN SPACE REQUIREMENT: SERVICES DEPARTMENT. 7. PLANTING SUBSTITUTIONS SHALL BE APPROVED IN WRITING BY THE WAUKEE DEVELOPMENT ADJACENT TO LAWN, UNLESS OTHERWISE DIRECTED BY OWNER. 6. BEDS SHALL BE VERTICAL CUT NATURAL EDGE TO A DEPTH OF 4 INCHES IN ALL BED AREAS ALL BEDS UNLESS OTHERWISE NOTED. 5. CONTRACTOR TO INSTALL 2 INCH RIVER GRAVEL ROCK MULCH TO A DEPTH OF 4 INCHES IN MULCH. 4. CONTRACTOR TO PROVIDE BLACK LANDSCAPE FABRIC IN ALL PLANT BEDS TO RECEIVE ROCK 3. SOD AREAS AS INDICATED ON PLANS AS PER SUDAS SPECIFICATION SECTION 9010. SPECIFICATIONS SECTION 9010. INSTALL AND MAINTAIN PER OWNER'S REQUIREMENTS. 2. SEED AREAS AS INDICATED ON PLANS WITH TYPE 1 PERMANENT LAWN MIXTURE AS PER SUDAS DIAMETER MINIMUM MULCH RING. 1. PROVIDE 3" MIN. DEPTH SHREDDED HARDWOOD MULCH ON ALL INDIVIDUAL TREES WITH A 5' 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= AWSV:\Projects\2017\117.0086.01\CADD\SP_1170086_08dtl.dgn2/20/20171:37:54 PMSnyder1:20Y:\pen\date.tblY:\print_drivers\Black_Gray\V8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.AUTUMN RIDGE PLAT 1, LOT 1WAUKEE, IA1170086 9KMMBKCAWS01/24/17117008691REVISED PER CITY COMMENTS02/07/17AWS2REVISED PER CITY COMMENTS02/21/17AWSNO SCALE PLANTING PIT DETAILS SLOPE PLANTING PIT DETAIL SCARIFY SIDES OF PIT LOCATED AT TOP OF ROOTBALL 2" OF TRUNK. ROOT COLLAR IS NOT ALWAYS FINISH GRADE. DO NOT PLACE MULCH WITHIN SET ROOT COLLAR AND ROOT FLARE 2" ABOVE MINIMUM FOR SHRUBS 2X ROOTBALL MINIMUM FOR TREES 3X ROOTBALL ROOT SYSTEM OR CONTAINER DEPTH OF ROOT BALL EXISTING SLOPE FINISH GRADE PLACE ROOT BALL ON UNDISTURBED SOIL TREE OR SHRUB ROOT BALL BEGIN TRANSITION AT EDGE OF 2:1 MAXIMUM TRANSITION SLOPE. MINIMUM 6' DIAMETER, 3" DEPTH MULCH RING BEYOND EDGE OF ROOT BALL 3" HEIGHT WATER RETENTION BERM BASKET MINIMUM. MINIMUM TOP 1/2 OF BURLAP AND WIRE BALLED AND BURLAP (B&B) PLANTS REMOVE MATERIAL. REMOVE ALL TWINE. FOR IMPEDE THE GROWTH OF THE PLANT CONTAINERS OR OTHER MATERIAL THAT WILL REMOVE ALL NON-BIODEGRADABLE MATERIAL, Root Ball Diameter 1 1/2 to 2 Tim es SCARIFY SIDES OF PIT TYPICAL PLANTING PIT DETAIL LOCATED AT TOP OF ROOTBALL 2" OF TRUNK. ROOT COLLAR IS NOT ALWAYS FINISH GRADE. DO NOT PLACE MULCH WITHIN SET ROOT COLLAR AND ROOT FLARE 2" ABOVE MINIMUM FOR SHRUBS 2X ROOTBALL MINIMUM FOR TREES 3X ROOTBALL ROOT SYSTEM OR CONTAINER DEPTH OF ROOT BALL FINISH GRADE PLACE ROOT BALL ON UNDISTURBED SOIL BEYOND EDGE OF ROOT BALL 3" HEIGHT WATER RETENTION BERM BASKET MINIMUM. MINIMUM TOP 1/2 OF BURLAP AND WIRE BALLED AND BURLAP (B&B) PLANTS REMOVE MATERIAL. REMOVE ALL TWINE. FOR IMPEDE THE GROWTH OF THE PLANT CONTAINERS OR OTHER MATERIAL THAT WILL REMOVE ALL NON-BIODEGRADABLE MATERIAL, MINIMUM 6' DIAMETER, 3" DEPTH MULCH RING 1 1 NO SCALE TREE DRAINAGE WELL DETAIL Diameter 8" to 12" 6' DEPTH SEE PLANTING PIT DETAIL FINISH GRADE IMPERVIOUS SOIL SEPTIC GRAVEL {IF PRESENT} PERVIOUS SOIL BY ENGINEER. INSTALLATION; AS APPROVED IMPERVIOUS SOILS ARE FOUND DURING TREE DRAINAGE WELL ONLY REQUIRED IF NOTE: into the pervious soil layer. extends a minimum of 12 inches well may be termineated when the well depth less the 6 feet, the drainage If pervious soil is encountered at a ENGINEERING FABRIC NO SCALE FIRE HYDRANT ASSEMBLY 6'' (Trees larger than 2 1/2 inch diameter) STAKING PLAN 1 1 (4'-0" MIN.) TREE HEIGHT 1/2 TO 2/3 (2'-0" MIN.) TREE HEIGHT 1/4 TO 1/3 6" NO SCALE DECIDUOUS TREE STAKING DETAIL TO SOUTHWEST PLACE ON STAKE TO SOUTHWEST PLACE ON STAKE inch diameter or smaller}2 1{Trees 2 STAKING PLAN MATERIAL FLAGGING GARDEN HOSE DETAILS SEE PLANTING PIT branch. Wrap trunk from ground line to first MISCELLANEOUS DETAILS8 820'EXTERIOR WALL FLOOR SLAB (LOCATIONS PER PLAN) @ MIN S= 1.00% 6" N-12 HDPE STORMSEWER DOWNSPOUT INTO PIPE COVER CAP STORMPIPE AND EXTEND (SEE ARCH PLANS) PROPOSED DOWNSPOUT FOUNDATION WALL PROPOSED NO SCALE DOWNSPOUT CONNECTION DETAIL VALVE BOX ANCHORING TEE OR STANDARD UNDISTURBED EARTH TEE AND ANCHORING COUPLING2'-0"DEPTH VARIES1'-0" X 1'-0" X 4" CONCRETE PAD BACKFILL WITH 3/4" WASHED GRAVEL MAIN TRENCH WALL VARIES WATER MAIN THRUST BLOCKANCHORING PIPE GATE VALVE HYDRANT NOTES MINIMUM SIZE FOR PIPING. VALVES AND FITTINGS FROM WATER MAIN TO HYDRANT INLET: 6". 1.MIN. 5'-6"18" MIN. OR TRACER WIRE. NOT COVER DRAIN HOLES UNDISTURBED EARTH. DO THRUST BLOCK AGAINST POURED CONCRETE PROVIDE TRACER WIRE AND TRACER WIRE STATION.2. WRAP HYDRANT, PIPE AND FITTINGS WITH POLYETHYLENE ENCASEMENT. 3. TRACER WIRE STATION STORZ COUPLING AND CAP 0" TO 6"DEPTH VARIES PER PLANMIN 4" PAVEMENT PROPOSED EROSION CONTROL MEASURES D DVARIES SAME DIMENSION AS END SECTION FLARED END SECTION A A FLARED END SECTION DELEVATION SECTION A-A #4 BARS @ 18" ON CENTER UNDISTURBED SOIL VARIABLE CONCRETE FOOTING 6" 1'- 0"MIN. SECTION PIPE JOINT. WATERSTOP AT FLARED END INSTALL 3' WIDE CLAY 2. OF FLARED END;MINIMUM D=42" FLOW LINE 300 FT DOWNSTREAM AND DRAINAGE WAY CHANNEL BETWEEN FLARED END INVERT D=DIFFERENCE IN ELEVATION 1. NOTES: MAX. FORMED VERTICAL FACE NO SCALE FES FOOTING DETAIL 6 7 4 2 3 height: 0" to 2" Drop curb 1'-0" min. Curb opening 18"12" Driveway width NO SCALE CONCRETE DRIVEWAY, TYPE A 5 DETAIL B 2 7Back of curb 1 R bar reinforcing #5 x 36" 1'-0" TYPICAL SECTION Curb Driveway SidewalkPr o pert y line TYPE A WITH RADII as specified Detail B Refer to curb Back of 8 2 'E' joint joint 'C' or 'E' 'B' joint 'C' joint 9 10 10 1'-0" 8 1 8 2 8 3 8 4 8 5 8 6 8 7 detectable warning panel with Engineer. Figure 7030.205; verify need for change requires a curb ramp, comply with sidewalk through driveway. If elevation transition from existing sidewalk to exceeds 2.0%, remove and replace to If cross slope of adjacent sidewalk panel passing space. driveway 5 feet wide to serve as a construct the sidewalk through the specified in the contract documents, maximum cross slope of 2.0%. If Target cross slope of 1.5% with a 2% toward center of alley. For alleys, invert the pavement crown 'B' joint is specified. Provide 'E' joint at back of curb unless 10 9 8 7 6 5 4 3 2 1 8 inches minimum. Match thickness of adjacent roadway, pavement. Center reinforcing bar vertically in the match thickness of driveway. Sidewalk thickness through driveway to minimum. Commercial and industrial: 7 inches Residential: 6 inches minimum. Pavement thickness. across sidewalk. of sidewalk. Do not extend raised curb end of taper/radius or at the front edge Transition the curb height to 0 inches at specified in the contract documents. Commercial and industrial: As maximum. Residential: 10 foot minimum,15 foot Driveway radius (R). BYDATEREVISIONMARKScale:Checked By:Engineer:Technician:Date:Field Bk: Pg:1"= AWSV:\Projects\2017\117.0086.01\CADD\SP_1170086_09dtl.dgn2/20/20171:37:56 PMSnyder1:10Y:\pen\date.tblY:\print_drivers\Black_Gray\V8iBWFullWeightPDF.pltcfgSheetofSheet of Project No:SNYDER & ASSOCIATES, INC.Project No:515-964-2020 | www.snyder-associates.comANKENY, IOWA 500232727 S.W. SNYDER BLVD.AUTUMN RIDGE PLAT 1, LOT 1WAUKEE, IA1170086 9KMMBKCAWS01/24/17117008691REVISED PER CITY COMMENTS02/07/17AWS2REVISED PER CITY COMMENTS02/21/17AWSTENANT2,000 SFAUTUMN RIDGE PLAT 1SPRINKLERFDC15" RCP24" RCPConcreteICVO1052.34 1052.34 1051.84 1051.93 7.63% 6.35%0.00%1.39%1.67%1052.40 1052.30 1052.05 1052.15 1051.65 1051.55 1051.55 1051.65 1052.05 1052.15 1052.00 1051.30 1051.401052.05 1051.25 1051.35 1051.40 1051.35 1051.25 1051.30 1.67%5.56%0.00%5.26%1.67%1.67%1.67% 1.77%5.42%5.83%5.83% 5.46% 0.91% 0.91%0.91%0.91%1.84% 1.84% 2.83% 4.57% 1.28% 1.25% 4.60% 4.55%1.25%1.25%1.25%1.25%1.77%6.39%6.50%1.00%0.54 % 0.36%0.00%6.50%5.49%1.25%1.25%1.25%1.25% 1. 7 7 %1051.20 1051.10 1051 .37 1051.43 1051.37 1051.31 1049.06 1049.12 1049.061048.991048.56 1048.63 1048.60 1048.84 1048.82 1049.18 1049.25 1049.31 1049.25 1048.841.22%1.25%2.00%1.77%1.67%0.83%1.67%0.83% 1.64% 1.67% 0 SCALE (FEET) 10 SIDEWALK DETAILS9 910'1.23%1052.211052.251052.31 1052.301052.42 1052.15 2.00% 1.79%1.43%1.62%1.67%1.62%1.43%0.85% 1048.71 1048.75 1048.90 1048.86 2017.02.20 DARK GRAY BRICK TAN-COLORED, SAND- TEXTURED EIFS METALLIC GRAY RIBBED METAL PANELS DARK GRAY BRICK TAN-COLORED, SAND- TEXTURED EIFS 12’ X 12’ ALUMINUM AND GLASS OVERHEAD DOORS METALLIC GRAY RIBBED METAL PANELS 12’ TALL ALUMINUM AND GLASS CURTAINWALL F R O N T (S O U T H) E L E V A T I O N - F A C E S S E O L S E N D R I V E B A C K E L E V A T I O N W E S T E L E V (FA C E S A L I C E ‘ S R O A D) TAN-COLORED, SAND- TEXTURED EIFS DARK GRAY BRICK METALLIC GRAY RIBBED METAL PANELS T R A S H E N C L O S U R E NEW RETAIL CENTER PLANNED FOR: AUTUMN RIDGE PLOT 1, LOT 1, WAUKEE, IA E A S T E L E V