Loading...
HomeMy WebLinkAbout2016-03-21-J08 Central Plaza_Site Plan AGENDA ITEM: CITY OF WAUKEE, IOWA CITY COUNCIL MEETING COMMUNICATION MEETING DATE: March 21 2016 AGENDA ITEM: Consideration of approval of a resolution approving site plan for Central Plaza [1135 SE Alice’s Road] FORMAT: Resolution SYNOPSIS INCLUDING PRO & CON: The applicants, Greater Iowa Credit Union and Three-Sixty Group, request approval of a site plan for a multi-tenant commercial building proposed to be located at the northeast corner of SE Alice’s Road and SE University Avenue. The site plan indicates a 10,650 square feet building with three tenant spaces. The building will have the ability to be further subdivided in the future. The site plan identifies a coffee shop on the north side of the building and a credit union on the south side of the building. Both will have drive-thru windows. Access to the site will be provided via a private road on the north side of the property and SE University Avenue. The applicant has provided elevations of the proposed building. Staff has reviewed the elevations and feels they meet the intent of the Site Plan Ordinance. The building is proposed to be constructed of brick, EIFS, metal paneling, and glazing. The applicant has requested a new address for the site. The current address for the site is 1155 SE University Avenue. Because the building will face SE Alice’s Road the applicant has requested an address of 1135 SE Alice’s Road. A separate cover sheet and resolution have been prepared for the address change request. FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS: COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning Commission reviewed the request at their meeting on March 8, 2016 and recommended approval subject to remaining staff comments: Approval of a Site Plan for Central Plaza (1155 SE University Avenue) Waukee Senior Planner Andy Kass introduced a request for a site plan approval proposed by the Greater Iowa Credit Union and the Three-Sixty Group. The Property in question is 1.46 acre lot within Williams Point Plat 15, located east of SE Alice’s Road and north of SE University Avenue. The Subject property was originally rezoned in 2005 as part of a planned development. The applicants are proposing to construct a multi-tenant retail/commercial building. The building would be 10,650 square feet separated into three tenant spaces. Spaces for a coffee shop and a credit union have been identified on the plans submitted. Both the coffee shop and credit union spaces are proposed to both have drive-thru windows. The trash enclosure would be located on the east side of the building. The exterior lighting for the site has been reviewed and is in compliance with the site plan ordinance. Access to the site will be provided via and existing unnamed private road on the north side of the property and SE University Avenue. The private road provides access to SE Alice’s Road and SE Brick Drive. SE University Avenue will be restricted to a right-in and right out access only. Sanitary and water services have already been extended to the lot from previous plats of the property. Storm water detention will be provided in the adjacent outlet. The coffee shop portion of the building will be connected to a grease interceptor. The site plane ordinance requires 20% open space for this site and the site plan indicates that 20.2% will be provided. Landscaping has been provided in compliance with the required planting requirements. The elevations propose pre-finished metal paneling, brick, glazing, burnished block, and EIFS as some of the proposed building materials. There is a possible plan for a monument sign, subject to staff approval. These elevations meet the compliance required and Staff is comfortable recommending an approval of the site plan. • Commissioner Schmidt brought up a major intersection and architectural water feature that was discussed for this particular area upwards of 10 years ago. Mr. Kass advised that it could be implemented down the road for future improvements to the corridor, but right now there were not proposed plans. • Commissioners Streit and Hoifeldt questioned whether the intersections along the private road would be signalized and Mr. Kass advised that the street was not held to any public regulations, but that at a certain point of traffic, it would be signaled. • Commissioner Schmidt wanted a clarification on the distance between SE Brick and SE university for viability of signaling. Mr. Kass advised that there would need to be 600-800 feet between each road on the corridor to install signal lights. • Commissioner Nigro brought up the fact that this area has the potential to grow and wanted more clarification on how the city would handle addressing the properties. Mr. Kass advised that at this time the tenants would have SE University Avenue addresses, however the applicant can change the address if they so choose as the current proposition was just for the consistency of the plat. The fire department, as long as they have a monument sigh and as long as the address is visible on that sign, would consider an address change. If they do not plan to add a monument sign then the fire department would need to be consulted to find a solution. To answer Commissioner Schmidt’s question regarding how the separation of tenant sections would be offered, Mr. Kass advised that it would most likely be suite numbers over lot numbers. • Commissioner Hoifeldt questioned if the road to the east which is the private drive, is a full width road, or is planned to be. Mr. Kass advised that it would be made into a full width road. • Commissioner Nigro wanted further explanation of the landscaping provided on the side that faces the lot owner to the east, as that is the back side of this building. Mr. Kass advised that there was some landscaping that complies with the ordinances. Commissioner Schmidt mentioned that the lot to the east could turn their back entrance to face the back of this building to optimize the visual appeal of the property. • Commissioner Hoifeldt wanted some clarification on the logistics regarding the accessibility of the dumpster in the SE corner and a concern that the truck would not be able to get in to the structure. • Tim Walpole from Three-Sixty Group advised that the trash is mostly a management issue. The radius shows that the trucks can fit, the dumpster will have to be rolled out of the enclosure and back in though. • Commissioner Hoifeldt questioned the stacking on the parking for the coffee shop. Mr. Walpole advised that there were parking spaces on the east side of the building. He also advised that the proposed flow is to enter on the south east corner and follow the loop of the building to reach the menu signs and exit to minimize traffic congestion in the area. • Commissioner Hoifeldt questioned about what materials were going to be used and Mr. Walpole advised that the front is mainly glass and two colors of stone and brick. The top band will have a metal-like smooth finish and LED lights behind frosted glass panels for interest on the front of the store systems. He also advised that the top band of the windows will have a 3M film applied to help minimize the glare into the shops. He also clarified that each individual store would have their own signage done in blocked letters only, no flat signs. Mr. Walpole also advised that the rooftop units would be screened from sight by the Para petted roof. Motion by Commissioner Nigro, seconded by Commissioner Fontenot to approve the Site Plan for Central Plaza (1155 SE University Avenue), subject to any remaining staff comments and review of all legal documents by the City Attorney. Ayes: Fontenot, Streit, Nigro, Hoifeldt, Broderick, Schmidt and Shanks. Nays: none. Motion carried. STAFF REVIEW AND COMMENT: At this time a majority of staff comments have been addressed, staff is confident that the remaining comments will be addressed prior to Council approval. Staff recommends approval subject to remaining staff comments. RECOMMENDATION: Approve the Resolution. ATTACHMENTS: I. Proposed Resolution II. Staff Report III. Staff Comment Letter IV. Site Plan V. Building Elevations PREPARED BY: Andy Kass, Senior Planner REVIEWED BY: PUBLIC NOTICE INFORMATION THE CITY OF WAUKEE, IOWA RESOLUTION 16- APPROVING THE SITE PLAN FOR CENTRAL PLAZA (1135 SE ALICE’S ROAD) IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal Organization; AND, WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval subject to remaining staff comments of the Site Plan for Central Plaza on March 8, 2016; AND, WHEREAS, the Site Plan for Central Plaza is in general conformance with §304 – Site and Building Development Standards Ordinance of the Waukee Municipal Code; AND, WHEREAS, the Site Plan for Central Plaza is in general conformance with §301.27(A) – Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND, NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this 21st day of March 2016 that the Site Plan for Central Plaza is approved subject to remaining staff comments. ____________________________ William F. Peard, Mayor Attest: ___________________________________ Rebecca D. Schuett, City Clerk ROLL CALL VOTE AYE NAY ABSENT ABSTAIN Shane Blanchard Brian Harrison Shelly Hughes Larry R. Lyon Rick Peterson STAFF REPORT TO: Planning and Zoning Commission PREPARED BY: Andy Kass RE: Central Plaza – Site Plan DATE: March 8, 2016 GENERAL INFORMATION: Applicant: Greater Iowa Credit Union & Three-Sixty Group Requested Action Site Plan Approval Location and Size: Property is generally located east of 6th Street and north of SE University Avenue containing approximately 1.46 acres more or less. LAND USES AND ZONING: Location Existing Land Use Comprehensive Plan Current Zoning Property in Question Vacant – Undeveloped Community Village PD/C-1A North Vacant – Undeveloped Community Village PD/C-4 & PD/C- 1A South Vacant – Undeveloped Community Village C-1 East Winhall at Williams Pointe / People’s Trust and Savings Bank Neighborhood Residential PD/R-3 & PD/C- 1A West Gilcrest Jewett Community Village C-1A & M-1A BACKGROUND: The property in question is a 1.46 acre lot within Williams Pointe Plat 15, located east of SE Alice’s Road and north of SE University Avenue. The subject property was originally rezoned in 2005 as part of a planned development and has been platted a number of different times. The applicants, Greater Iowa Credit Union and Three-Sixty Group propose to construct a multi-tenant retail/commercial building. March 4, 2016 2 of 3 ABOVE: Aerial of Concept Plan identifying the proposed transportation facility and Surrounding Properties. PROJECT DESCRIPTION: The project involves the construction of a 10,650 square foot multi-tenant retail/commercial building. The site plan identifies three tenant spaces. Spaces for a coffee shop and a credit union have been identified on the plan set. The coffee shop and credit union spaces are proposed to both have drive-thru windows. The trash enclosure for the proposed building is located on the east side of the site. The proposed exterior lighting for the site has been reviewed and is in compliance with the Site Plan Ordinance. ACCESS AND PARKING Access to the site will be provided via an existing unnamed private road on the north side of the property and SE University Avenue. The private road provides access to SE Alice’s Road and SE Brick Drive. Ingress and egress via SE university Avenue will be restricted to right-in right-out access only. The Parking Ordinance requires 46 spaces for this site and the site plan identifies a total of 49 parking spaces. Queuing spaces are also required for the drive-thru windows for which 6 are required and 10 have been provided. March 4, 2016 3 of 3 UTILITIES Sanitary and water services have already been extended to the lot from previous plats of the property. Storm water detention will be provided in the adjacent outlet. The coffee shop portion of the building will be connected to a grease interceptor. LANDSCAPING The site plan ordinance requires 20% open space for this site and the site plan plan indicates that 20.2% will be provided. Landscaping has been provided along the perimeter of the site in compliance with require planting requirements. ELEVATIONS Pre finished metal paneling, brick, glazing, burnished block, and EIFS are some of the proposed building materials. The proposed elevations meet the intent of the Site Plan Ordinance with respect to architectural requirements. All mechanical units will be roof mounted and will be screened. STAFF RECOMMENDATION At this time Staff is comfortable with the site plan and would recommend approval of the site plan subject to remaining staff comments and review of all legal documents by the City Attorney. CITY OF WAUKEE Andy Kass, AICP Senior Planner Development Services Department 230 W. Hickman Road Waukee, IA 50263 Phone: (515) 978-9533 Fax: (515) 987-1845 1st Review: January 26, 2016 2nd Review: February 23, 2016 3rd Review: 4th Review: Civil Design Advantage Attn: Keith Weggen 3405 SE Crossroads Drive, Suite G Grimes, Iowa 50111 RE: Central Plaza – Site Plan Dear Mr. Weggen: Per your request, staff has reviewed the proposed site plan for Williams Pointe Retail. The property is located at the northeast corner of NE Alice’s Road and SE University Avenue. Based upon our review, staff has the following comments related to the site plan: COVER SHEET & GENERAL COMMENTS 1. The zoning should be update to PD/C-1A 2. A photometric plan should be provided for review along with manufacturers cut sheets for all proposed exterior fixtures. 3. Provide project manager contact information. 4. Building material samples should be provided for review. 5. A storm water management plan should be submitted for review. SHEET C1.1 | TOPOGRAPHIC SUVEY & DEMOLITION PLAN 6. Provide recorded book and page numbers for all existing easements. SHEET C2.1 | DIMENSION PLAN 7. Please provide total building square footage. 8. Provide a detailed elevation of the trash enclosure. A full detail of the trash enclosure should be provided for review. The detail provided is not adequate. Engineers Response: 9. A note should be added to the site plan indicating that all proposed signage will require a permit from the City of Waukee Development Services Department. 10. General Note #19 should also include all pedestrian facilities. 11. Future uses of space in the proposed building will be limited due to the provided parking. Any potential future user will need to meet required parking per the Ordinance. Utilizing the flex space Project Name Project Engineer/Manager Project Type City Contact Central Plaza Keith Weggen Site Plan Andy Kass requirement (8 spaces/1,000 square feet of building area) would allow future uses to be more flexible. SHEET C3.1| GRADING PLAN 12. 100 year flood elevations should be indicated and illustrated for all detention and sump areas on site, including any offsite facilities. 13. Overflow elevations and routes should be indicated and illustrated by using directional arrows. 14. A Sediment and Erosion Control Plan should be provided for review. 15. An area of disturbance calculation should be provided. 16. Label this sheet as Grading and Sediment & Erosion Control Plan 17. Provide proposed construction exit location. 18. Provide proposed concrete washout location. 19. Provide proposed topsoil stockpile location. 20. Provide final discharge locations for storm water and name of ultimate receiving water bodies. Provide discharge information for the north FES that outlets into the basin. 21. An area of disturbance calculation should be provided. 22. Please show the proposed inlet protection device locations. 23. Grading Note #2 should be changed to 8-inch topsoil depth per SUDAS. 24. Staff questions if Grading Note #12 is applicable. 25. Grading Notes 13 and 16 can be removed as they do not appear to be applicable to this project. SHEET C4.1 | UTILITY PLAN 26. Staff questions if gas service is planned for the proposed buildings. If so, please indicate anticipated gas meter locations. Please address. 27. Valves will need to be provided on both the domestic service and fire service. 28. All critical crossings should be called out with top and bottom of pipe elevations. 29. A note should be added to the plan set indicating that any field tiles encountered during construction should be repaired, reconnected, or rerouted and their locations should be noted on as-built drawings. 30. The 15-inch storm sewer on the south side should be 15-inch RCP as Waukee Standard Specifications require RCP in the public right-of-way. 31. Please indicate the size of the grease interceptor. 32. Label fittings at the water main split. 33. Install footing and apron and erosion protection at storm outlets. 34. Provide class of rip-rap to be installed. SHEET C5.1 | DETAILS 35. Staff questions if Detail #1 is applicable to this project. Please address. SHEET L1.1 | LANDSCAPE PLAN 36. The setback area between parking areas and the right-of-way are required to be planted with a minimum of one (1) overstory deciduous tree per 40 lineal feet. 37. A note should be added to the Landscape Plan indicating that approval from the City of Waukee is required for substitutions. 38. All disturbed areas should be noted to be sodded per the Landscape and Open Space Ordinance. 39. A note should be added to the Landscape Plan indicating that all disturbed offsite areas shall be replaced with sod and watered until established. 40. Ground mounted mechanical units should be indicated on the site plan. A screening detail should also be provided. BUILDING ELEVATIONS 41. The Site Plan Ordinance allows EIFS as an acceptable secondary building material. It appears that it is proposed to be used as a primary material on the north elevation and the east elevation of the proposed building. Staff would suggest adding additional brick or other materials to reduce the amount of EIFS used. FIRE DEPARTMENT COMMENTS 42. The fire hydrant assembly located on the east side of the building across from the FDC will need to be moved closer to parking lot and turned so it faces parking lot. The fire hydrant shall be maintained with a 5 – foot clear space around the circumference. Page L1.1 shows a tree that could be within the clearance area of the hydrant. 43. The FDC is in the appropriate location. Please provide a note informing FDC will be 2 - 2 1/2" connections with providing Locking Knox caps. 44. Provide location of Knox Box on handle side of door no more than 6 feet from ground level next to the exterior door of the riser and fire alarm room. MISCELLANEOUS COMMENTS: 45. Provide a copy of the Construction Site SWPPP Review Checklist signed by the SWPP designer. Engineers Response: 46. Provide a copy of the SWPPP Prepared for obtaining General Permit #2 coverage. Engineers Response: 47. Provide a copy of the IDNR issued General Permit #2 authorization letter. Engineers Response: 48. Complete COSESCO application and submit with $65 fee for the first required quarterly COSESCO inspection. Engineers Response: The applicant will be required to provide the following as a part of the completion of the public improvements prior to approval of a final plat: 49. Post Construction What practices considered for this site? 50. Provide a site plan specific to the storm water management facilities of the property indicating the permanent measures utilized by the designer and requirements for maintenance of said facilities. 51. A maintenance covenant will need to be created and provided for review (if different than the existing). 52. As-built plans of all storm water management facilities on site and a certification statement signed by SWPPP designer indicating that facilities were constructed as designed will be required. Staff would request that the revised plans and comment response letter be provided in digital form (PDF) and hard copies with 5 full-sized hard copies delievered to Waukee City Hall. The PDF copy may be emailed. One additional hard copy set including any storm water management materials should be delivered directly to Veenstra and Kimm to Jordan Kappos’s attention. Staff anticipates forwarding this site plan request to the March 8th Planning & Zoning Commission meeting. Please have revisions submitted no later than March 1st in order to stay on schedule for the meeting date. Should you have any questions or concerns regarding these comments, please feel free to contact Brad Deets (515-978-7899), Melissa DeBoer (515-978-7898) or myself at (515) 978-7897. Sincerely, Andy Kass, AICP Senior Planner