HomeMy WebLinkAbout2021-09-20-I12 Enterprise Business Park Plat 1 Lot 5_Site Plan AGENDA ITEM:
CITY OF WAUKEE, IOWA
CITY COUNCIL MEETING COMMUNICATION
MEETING DATE: September 20, 2021
AGENDA ITEM: Consideration of approval of a resolution approving a site plan for Lot 5,
Enterprise Business Park Plat 1 (35 NE Venture Drive)
FORMAT: Resolution
SYNOPSIS INCLUDING PRO & CON: M&A Capital Partners, LLC, requests approval of a site
plan for a 23,400 square foot building for contractor storage. A monument
sign is shown at the southwest corner of the site off of NE Venture Drive.
The applicant has provided elevations for the proposed building on the site,
which meets the intent of the architectural guidelines within the Site Plan
Ordinance.
FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS:
COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning
Commission reviewed this project at the September 14, 2021 Commission Meeting and
recommended approval subject to remaining staff comments:
Approval of a Site Plan for Lot 5, Enterprise Business Park Plat 1 (35 NE Venture Drive)
Senior Planner, Melissa DeBoer, introduced the request for approval of a site plan as submitted by the
applicant M&A Capital Partners LLC, for a contractor storage building. The subject property is
generally located north of NE Venture Drive and east of Warrior lane, containing approximately 1.53
acres.
Mrs. DeBoer advised that the site plan identifies the construction of a 23,400 square foot contractor
storage building and a monument sign at the southwest corner of the site off of NE Venture drive.
Access will be provided off of NE Venture Drive into the site. A total of 40 parking spaces are
provided with this project exceeding the required amount, and a five foot side walk is identified on the
north side of NE Venture Drive. The site will be serviced with public utilities and storm water
detention will be provided in a shared detention basin located to the north of the site. All Landscape,
open space, and elevation requirements have been met at this time.
Staff would recommend approval of the site plan for Lot 5 of Enterprise Business Park Plat 1 subject
to remaining staff comments.
Commissioner Hoifeldt moved to approve the Site Plan for Lot 5 of Enterprise Business Park Plat 1
subject to any remaining staff comments. Commissioner Streit seconded the motion. Ayes: Streit,
Broderick, Hoifeldt, and Koshy. Nays: none. Motion carried.
STAFF REVIEW AND COMMENT: Staff recommends approval of the site plan subject to
remaining staff comments.
I12
RECOMMENDATION: Approve the resolution subject to remaining staff comments.
ATTACHMENTS: I. Proposed Resolution
II. Staff Report
III. Site Plan & Elevations
PREPARED BY: Melissa DeBoer, Senior Planner
REVIEWED BY:
THE CITY OF WAUKEE, IOWA
RESOLUTION 2021-
APPROVING THE SITE PLAN FOR LOT 5, ENTERPRISE BUSINESS PARK PLAT 1
(35 NE VENTURE DRIVE)
IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA
WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal
Organization; AND,
WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of
the Site Plan for Lot 5, Enterprise Business Park Plat 1, subject to remaining staff comments on
September 14, 2021; AND,
WHEREAS, the Site Plan for Lot 5, Enterprise Business Park Plat 1 is in general conformance
with §160 – Site and Building Development Standards Ordinance of the Waukee Municipal
Code; AND,
WHEREAS, the Site Plan for Lot 5, Enterprise Business Park Plat 1 is in general conformance
with §161 – Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND,
NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on
this 20th day of September, 2021 that the Site Plan for Lot 5, Enterprise Business Park Plat 1 is
approved subject to remaining staff comments.
____________________________
Courtney Clarke, Mayor
Attest:
___________________________________
Rebecca D. Schuett, City Clerk
RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN
Anna Bergman Pierce
R. Charles Bottenberg
Chris Crone
Larry R. Lyon
Ben Sinclair
PLANNING AND ZONING COMMISSION STAFF REPORT
PROJECT: Lot 5, Enterprise Business Park Plat 1
– Site Plan
PREPARED BY: Melissa DeBoer, AICP – Senior Planner
REPORT DATE: September 10, 2021
MEETING DATE: September 14, 2021
GENERAL INFORMATION
Applicant: M&A Capital Partners, LLC
Owner:
Thomas Dickson
Engineer: Korey Marsh, P.E. – Snyder & Associates, Inc.
Request: The applicant is requesting approval of a site plan
for a contractor storage building.
Location and Size: Property is located north of NE Venture Drive and
east of Warrior Lane, containing approximately
1.53-acres.
Property Address: 35 NE Venture Drive
AREA MAP
ABOVE: Aerial of subject property (outlined in RED) in relation to the surrounding area.
September 10, 2021
2 of 2
LAND USES AND ZONING
Location Existing Land Use Comprehensive Plan Current Zoning
Property in
Question
Vacant – Undeveloped Community Commercial M-1 (Light Industrial District)
North Waukee Community Church Community Commercial M-1 (Light Industrial District)
South Self-Storage Mixed Use M-1 (Light Industrial District)
East Industrial Warehouse Community Commercial M-1 (Light Industrial District)
West Commercial Community Commercial M-1 (Light Industrial District)
& C-1 (Community and
Highway Service
Commercial District)
PROJECT DESCRIPTION
The site plan identifies the construction of a 23,400 square foot contractor storage building. A monument sign
is shown at the southwest corner of the site off of NE Venture Drive.
ACCESS AND PARKING
One access is provided to the site off of NE Venture Drive.
A total of 34 parking spaces are required for this project. The total amount of parking proposed is 40 parking
spaces, including two accessible spaces. The proposed site plan meets the parking requirements.
SIDEWALKS/TRAILS
A 5-foot-wide sidewalk will be constructed on the north side of NE Venture Drive.
UTILITIES
The site will be serviced with all public utilities. Water and sanitary will be brought in from the mains located
along NE Venture Drive. Stormwater detention will be provided with a shared detention basin located to the
north of this site.
LANDSCAPING & OPEN SPACE
A minimum of 15% of the project area is required to be open space. The total amount of open space
proposed is 17%. The plantings shown on the landscape plan meet the minimum requirements of the
Landscape & Open Space Ordinance.
ELEVATIONS
Colored building elevations are included for review. The building is proposed to be constructed mostly of
Nichiha Stone, metal panel system and overhead doors.
STAFF RECOMMENDATION
Staff recommends approval of the site plan for Lot 5, Enterprise Business Park Plat 1 subject to remaining staff
comments.
HICKMAN ROAD
NE VENTURE DR
NE SUNRISE DR
NE DARTMOOR DRNE WESTGATE DRWARRIOR LNSITE PLANS
FOR
LOT 5, ENTERPRISE BUSINESS PARK PLAT 1
35 NE VENTURE DRIVE
CITY OF WAUKEE, DALLAS COUNTY, IOWA
VICINITY MAP
PROJECT LOCATION
NOT TO SCALE
OWNER
THOMAS DICKSON
2164 NW 140TH ST
CLIVE, IOWA 50325
DEVELOPER
M&A CAPITAL PARTNERS, LLC
3693 NW 178TH CT
CLIVE, IOWA 50325
CONTACT: MATT SCHILLING
PHONE: (319) 330-0003
ENGINEER
SNYDER &ASSOCIATES
2727 SW SNYDER BLVD
ANKENY, IOWA 50023
CONTACT: KOREY MARSH
PHONE: (515) 964-2020 BYDATEREVISIONMARKScale:Technician:T-R-S:SNYDER & ASSOCIATES, INC. |Checked By:Engineer:Date:1" =Project No:SheetProject No:
Sheet 2727 S.W. SNYDER BLVDANKENY, IOWA 50023515-964-2020 | www.snyder-associates.comEDCRMBKMM07/19/2021500'121.0643C100121.0643
C100LOT 5, ENTERPRISE BUSINESS PARK PLAT 1TITLE SHEETWAUKEE, IOWAAS PER CITY COMMENTSAS PER CITY COMMENTS 08/17/2108/31/21 JRCJRC 12 TTN-RRW-SSV:\Projects\2021\121.0643.01\CADD\SP_1210643_PLAN.dwg JAKE R. CAMPOS, TITLE SHEET, 2021/08/31, 8:14 AM, ANSI FULL BLEED D (34.00 X 22.00 INCHES)I hereby certify that this engineering document
was prepared by me or under my direct personal
supervision and that I am a duly licensed
Professional Engineer under the laws of the
State of Iowa.
Korey M. Marsh, P.E.Date
License Number P25347
My License Renewal Date is December 31, 2022
Pages or sheets covered by this seal:
KOREY M.
MARSH
P25347DPROFELNSEICEIONALENGINEER
AIOW
SS
Index of Sheets
Sheet Number Sheet Title
C100 TITLE SHEET
C101 PROJECT INFORMATION
C200 DIMENSION AND UTILITY PLAN
C300 STORM SEWER PLAN
C400 GRADING AND EROSION CONTROL PLAN
C500 PLANTING PLAN
PEFROSS
O
N
LA
I
AC PNALCDS CARHECETTIIA ETST F IO
AW
O
License Expires:
June 30, 2022
LARA F.
GULDENPFENNIG
668
LANDSCAPE
ARCHITECT
NO.
Lara F. Guldenpfennig, ASLA
License Number
Pages or sheets covered by this seal:
668
Date
I hereby certify that the portion of this technical
submission described below was prepared by me
or under my direct supervision and responsible
charge. I am a duly licensed Professional
Landscape Architect under the laws of the
State of Iowa.
C100-C400
C500
PROPERTY DESCRIPTION
ENTERPRISE BUSINESS PARK PLAT 1, LOT 5
PROPERTY ADDRESS
35 NE VENTURE DR.
WAUKEE, IOWA 50263
ZONING
M-1: LIGHT-INDUSTRIAL DISTRICT
BULK REGULATIONS
MAX HEIGHT: 40 FEET
BUILDING HEIGHT: 17 FEET 10.5 INCHES
MAX # OF STORIES: 3
FRONT YARD SETBACK: 30 FEET
REAR YARD SETBACK: 30 FEET
SIDE YARD SETBACK: NONE, EXCEPT WHEN ADJACENT TO R OR C-1 DISTRICT
OR STREET ROW THEN 40'
TOTAL LOT AREA 66,704 SF
TOTAL DISTURBED AREA 66,704 SF
PROPOSED BUILDING FOOTPRINT 23,400 SF
PROPOSED PAVEMENTS 31,984 SF
TOTAL IMPERVIOUS AREA (OVERALL)55,384 SF
MINIMUM OPEN SPACE: 15%
66,704 SF X0.15 = 10,006 SF REQUIRED
11,320 SF PROVIDED (17.0%)
GENERAL USE
CONTRACTOR SUITES
PARKING REQUIREMENTS
1.5 SPACES PER 1000 SF OF GROSS FLOOR AREA
22,400 SF/1000 x 1.5 PARKING STALLS= 34 STALLS REQUIRED
=40 STALLS PROVIDED
(INCLUDING 2 HANDICAP STALLS)BYDATEREVISIONMARKScale:Technician:T-R-S:SNYDER & ASSOCIATES, INC. |Checked By:Engineer:Date:1" =Project No:SheetProject No:
Sheet 2727 S.W. SNYDER BLVDANKENY, IOWA 50023515-964-2020 | www.snyder-associates.comEDCRMBKMM07/19/2021 121.0643C101121.0643
C101LOT 5, ENTERPRISE BUSINESS PARK PLAT 1PROJECT INFORMATIONWAUKEE, IOWAAS PER CITY COMMENTSAS PER CITY COMMENTS 08/17/2108/31/21 JRCJRC 12 TTN-RRW-SSV:\Projects\2021\121.0643.01\CADD\SP_1210643_PLAN.dwg JAKE R. CAMPOS, PROJECT INFORMATION, 2021/08/31, 8:14 AM, ANSI FULL BLEED D (34.00 X 22.00 INCHES)UTILITY QUALITY SERVICE LEVELS
QUALITY LEVELS OF UTILITIES ARE SHOWN IN THE PARENTHESES WITH THE UTILITY
TYPE AND WHEN APPLICABLE, SIZE. THE QUALITY LEVELS ARE BASED ON THE CI /
ASCE 38-02 STANDARD.
QUALITY LEVEL (D) INFORMATION IS DERIVED FROM EXISTING UTILITY RECORDS OR
ORAL RECOLLECTIONS.
QUALITY LEVEL (C) INFORMATION IS OBTAINED BY SURVEYING AND PLOTTING
VISIBLE ABOVE-GROUND UTILITY FEATURES AND USING PROFESSIONAL JUDGMENT
IN CORRELATING THIS INFORMATION WITH
QUALITY D INFORMATION.
QUALITY LEVEL (B) INFORMATION IS OBTAINED THROUGH THE APPLICATION OF
APPROPRIATE SURFACE GEOPHYSICAL METHODS TO DETERMINE THE EXISTENCE
AND APPROXIMATE HORIZONTAL POSITION OF SUBSURFACE UTILITIES.
QUALITY LEVEL (A) IS HORIZONTAL AND VERTICAL POSITION OF UNDERGROUND
UTILITIES OBTAINED BY ACTUAL EXPOSURE OR VERIFICATION OF PREVIOUSLY
EXPOSED SUBSURFACE UTILITIES, AS WELL AS THE TYPE, SIZE, CONDITION,
MATERIAL, AND OTHER CHARACTERISTICS.
UTILITY WARNING
THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY
INFORMATION AND/OR RECORDS OBTAINED. THE SURVEYOR MAKES NO
GUARANTEE THAT THE UTILITIES OR SUBSURFACE FEATURES SHOWN
COMPRISE ALL SUCH ITEMS IN THE AREA, EITHER IN SERVICE OR ABANDONED.
THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UTILITIES OR
SUBSURFACE FEATURES SHOWN ARE IN THE EXACT LOCATION INDICATED
EXCEPT WHERE NOTED AS QUALITY LEVEL A.
FEATURES EXISTING PROPOSED
Spot Elevation
Contour Elevation
Fence (Barbed, Field, Hog)
Fence (Chain Link)
Fence (Wood)
Fence (Silt)
Tree Line
Tree Stump
Deciduous Tree \\ Shrub
Coniferous Tree \\ Shrub
Communication
Overhead Communication
Fiber Optic
Underground Electric
Overhead Electric
Gas Main with Size
High Pressure Gas Main with Size
Water Main with Size
Sanitary Sewer with Size
Duct Bank
Test Hole Location for SUE w/ID
(*) Denotes the survey quality service level for utilities
Sanitary Manhole
Storm Sewer with Size
Storm Manhole
Single Storm Sewer Intake
Double Storm Sewer Intake
Fire Hydrant
Fire Hydrant on Building
Water Main Valve
Water Service Valve
Well
Utility Pole
Guy Anchor
Utility Pole with Light
Utility Pole with Transformer
Street Light
Yard Light
Electric Box
Electric Transformer
Traffic Sign
Communication Pedestal
Communication Manhole
Communication Handhole
Fiber Optic Manhole
Fiber Optic Handhole
Gas Valve
Gas Manhole
Gas Apparatus
Fence Post or Guard Post
Underground Storage Tank
Above Ground Storage Tank
Sign
Satellite Dish
Mailbox
Sprinkler Head
Irrigation Control Valve
LEGEND
○
1
2
2
5
X 1225.25
●
X
1
2
2
5
1225.25
FEATURES FOUND SET
Section Corner
1/2" Rebar, Cap # 11579
(Unless Otherwise Noted)
ROW Marker
ROW Rail
Control Point
Bench Mark
Platted Distance P
Measured Bearing & Distance M
Recorded As R
Deed Distance D
Calculated Distance C
Minimum Protection Elevation MPE
Centerline
Section Line
1/4 Section Line
1/4 1/4 Section Line
Easement Line
UTILITY CONTACT INFORMATION
UTILITY CONTACT FOR MAPPING INFORMATION SHOWN AS RECEIVED FROM
THE IOWA ONE CALL DESIGN REQUEST SYSTEM, TICKET NUMBER 552103586.
W1-WATER MAIN CITY OF WAUKEE
S1-SANITARY SEWER TIM ROYER
G1-GAS MAIN 515-978-7920
ST-STORM SEWER troyer@waukee.org
UE1-UNDERGROUND ELECTRIC MIDAMERICAN ENERGY
JAMIE NEER
515-252-6972
MECDSMDesignLocates@midamerican.com
CO1-COMMUNICATION CENTURYLINK
SADIE HULL
918-547-0147
sadie.hull@lumen.com
FO1-FIBER OPTIC AUREON NETWORK SERVICES
JEFF KLOCKO
515-830-0445
jeff.klocko@aureon.com
FO2-FIBER OPTIC CONSOLIDATED COMMUNICATIONS
JUSTIN GREV
507-386-3606
justin.grev@consolidated.com
CLEAR PER EMAIL XENIA RURAL WATER DISTRICT
LAIRD VAN DEE
515-676-2117
lvandee@xeniawater.org
NO RESPONSE MEDIACOM COMMUNICATIONS CORP
PAUL MAY
515-246-2252
pmay@mediacomcc.com
NO RESPONSE MI-FIBER
JACK JONES
515-897-9192
jack@grm.net
NO RESPONSE VERIZON
JOHN BACHELDER
972-729-7000
john.bachelder@verizon.com
CONTROL POINTS
IOWA STATE PLANE SOUTH COORDINATE SYSTEM
NAD83(2011)(EPOCH 2010.00) IARTN DERIVED - US SURVEY FEET
CP1 N=589621.83 E=1539093.82 Z=1024.01
CUT "X" ON CURB 15' SOUTH OF THE NORTHWEST CORNER OF
PARKING LOT TO REDLINE CROSSFIT, NORTHEAST SIDE OF SITE.
CP2 N=589138.94 E=1539117.04 Z=1023.27
CUT "X" ON CURB RADIUS 15' EAST OF INTAKE AT ENTRANCE TO
STORAGE MART, SOUTHEAST CORNER OF SITE.
CP3 N=589141.47 E=1538851.47 Z=1021.37
CUT "X" ON CURB 3' NORTH OF SPEED LIMIT SIGN ON THE SOUTH
SIDE OF VENTURE DRIVE, SOUTHWEST CORNER OF SITE.
CP4 N=589380.28 E=1538885.52 Z=1023.40
CUT "X" ON CURB CORNER 30' SOUTHEAST OF BRICK BUILDING,
WEST SIDE OF SITE.
CP5 N=589589.30 E=1538960.55 Z=1022.52
CUT "X" ON EAST CURB CORNER OF PARKING LOT TO WAUKEE
COMMUNITY CHURCH, NORTHWEST CORNER OF SITE.
BENCHMARKS
NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88 - GEOID12A)
IARTN DERIVED - US SURVEY FEET
BM500 N=589408.86 E=1538878.09 ELEV=1024.43
TRIANGLE AT SOUTHEAST CORNER OF CONCRETE TRANSFORMER
PAD, WEST SIDE OF SITE.
BM501 N=589128.26 E=1538972.05 ELEV=1023.97
BURY BOLT ON HYDRANT ON THE SOUTH SIDE OF VENTURE DRIVE
SOUTH OF FOR SALE SIGN, SOUTH SIDE OF SITE.
DATE OF SURVEY
JUNE 21, 2021
GENERAL NOTES
A. NOTIFY UTILITY PROVIDERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES AND COORDINATE WITH UTILITY
PROVIDERS AS NECESSARY DURING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXISTENCE, EXACT
LOCATION, AND DEPTH OF ALL UTILITIES. PROTECT ALL UTILITY LINES AND STRUCTURES NOT SHOWN FOR REMOVAL OR
MODIFICATION. ANY DAMAGES TO UTILITY ITEMS NOT SHOWN FOR REMOVAL OR MODIFICATION SHALL BE REPAIRED TO THE
UTILITY OWNER'S SPECIFICATIONS AT THE CONTRACTOR'S EXPENSE.
B. CONSTRUCTION OF ALL STREET AND UTILITY IMPROVEMENTS SHALL CONFORM TO THE 2020 WAUKEE STANDARD
SPECIFICATIONS FOR PUBLIC IMPROVEMENTS, 2021 STATEWIDE URBAN DESIGN AND SPECIFICATIONS (SUDAS) AND THE SOILS
REPORTS PREPARED BY OTHERS.
C. LENGTH OF UTILITIES SHOWN ON PLANS ARE DIMENSIONED FROM CENTERLINE OF STRUCTURE TO CENTERLINE OF
STRUCTURE.
D. ALL TRAFFIC CONTROL SHALL BE PROVIDED IN ACCORDANCE WITH REQUIREMENTS SET FORTH IN THE MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (MUTCD). WHEN CONSTRUCTION ACTIVITIES OBSTRUCT PORTIONS OF THE ROADWAY, FLAGGERS
SHALL BE PROVIDED. FLAGGERS SHALL CONFORM TO THE MUTCD IN APPEARANCE, EQUIPMENT AND ACTIONS. THE
CONTRACTOR SHALL NOTIFY THE CITY OF WAUKEE AT LEAST ONE WEEK PRIOR TO ANY ANTICIPATED LANE CLOSURE.
E. NOTIFY OWNER, ENGINEER, CITY OF WAUKEE AT LEAST 48 HOURS PRIOR TO BEGINNING WORK. CONTRACTOR SHALL ALSO
NOTIFY THE CITY OF WAUKEE PUBLIC WORKS DEPARTMENT AT LEAST 48 HOURS PRIOR TO ANY PLANNED WEEKEND OR
HOLIDAY WORK.
F. CONSTRUCT MANHOLES AND APPURTENANCES AS WORK PROGRESSES. BACKFILL WITH SUITABLE MATERIAL AND COMPACT
TO 95% MAXIMUM DENSITY.
G. IN THE EVENT OF A DISCREPANCY BETWEEN THE QUANTITY ESTIMATES AND THE DETAILED PLANS, THE DETAILED PLANS
SHALL GOVERN.
H. ALL FIELD TILES ENCOUNTERED DURING CONSTRUCTION SHALL BE RECONNECTED OR REPAIRED AND NOTED ACCORDINGLY
ON THE AS-BUILT DOCUMENTS.
I. DIMENSIONS, BUILDING LOCATION, UTILITIES AND GRADING OF THIS SITE ARE BASED ON AVAILABLE INFORMATION AT THE
TIME OF DESIGN. DEVIATIONS MAY BE NECESSARY IN THE FIELD. ANY SUCH CHANGES OR CONFLICTS BETWEEN THIS PLAN AND
FIELD CONDITIONS ARE TO BE REPORTED TO THE ARCHITECT/ENGINEER PRIOR TO STARTING CONSTRUCTION. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR LAYOUT VERIFICATION OF ALL SITE IMPROVEMENTS PRIOR TO CONSTRUCTION.
CONTACT CITY OF WAUKEE FOR APPROVAL OF ANY CHANGES AND THAT ANY CHANGES COMPLETED WITHOUT APPROVAL ARE
SUBJECT TO REMOVAL IN ORDER TO MEET THE CITY OF WAUKEE STANDARDS.
J. CONTRACTOR TO LOAD AND TRANSPORT ALL MATERIALS CONSIDERED TO BE UNDESIRABLE TO BE INCORPORATED INTO THE
PROJECT TO AN APPROVED OFF-SITE WASTE SITE.
K. CONTRACTOR TO STRIP AND STOCKPILE TOPSOIL FROM ALL AREAS TO BE CUT OR FILLED. RESPREAD TO FINISH GRADES TO
MEET SUDAS SPECIFICATIONS SECTION 2010 FOR TOPSOIL.
L. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS SHOWN ARE FINISHED GRADES AND/OR TOP OF PAVING SLAB (GUTTER),
UNLESS OTHERWISE NOTED.
M. THE CONTRACTOR IS RESPONSIBLE FOR CLEANING DIRT AND DEBRIS FROM NEIGHBORING STREETS, DRIVEWAYS, AND
SIDEWALKS CAUSED BY CONSTRUCTION ACTIVITIES AT THE END OF EACH WORK DAY AND PRIOR TO A RAIN EVENT.
N. THE ADJUSTMENT OF ANY EXISTING UTILITY APPURTENANCES TO FINAL GRADE IS CONSIDERED INCIDENTAL TO THE SITE
WORK.
O. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING EROSION AND SEDIMENT CONTROL MEASURES AS NECESSARY.
CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR MAINTAINING ANY EXISTING EROSION CONTROL MEASURES ON SITE AT THE
TIME OF CONSTRUCTION. GRADING AND SOIL EROSION CONTROL CODE REQUIREMENTS SHALL BE MET BY CONTRACTOR. A
COSESCO PERMIT IS REQUIRED FOR THIS PROJECT.
P. CONTRACTOR TO COORDINATE NATURAL GAS, ELECTRICAL, TELEPHONE AND ANY OTHER FRANCHISE UTILITY SERVICES WITH
UTILITY SERVICE PROVIDER, CITY OF WAUKEE, AND THE OWNER PRIOR TO CONSTRUCTION.
Q. IF STORM SEWER CROSSES ABOVE WATER MAIN OR CROSSES LESS THAN 18" BELOW A WATER MAIN THEN STORM SEWER
SHALL BE CONSTRUCTED OF REINFORCED CONCRETE WITH A FLEXIBLE O-RING GASKET RATED AT 13 PSI OR GREATER. O-RING
GASKET JOINTS SHALL BE INSTALLED ON EACH SIDE OF THE CROSSING UNTIL THE NORMAL DISTANCE FROM THE WATER MAIN
TO THE STORM SEWER IS AT LEAST TEN FEET.
R. A PRE-CONSTRUCTION MEETING WITH THE CITY OF WAUKEE WILL BE REQUIRED A MINIMUM OF ONE WEEK PRIOR TO
CONSTRUCTION ACTIVITIES BEGINNING.
S. ALL STAKING SHALL BE DONE UNDER THE DIRECTION OF A LICENSED ENGINEER OR LAND SURVEYOR INCLUDING PEDESTRIAN
FACILITIES.
T. ANY CHANGES PROPOSED TO THE DRAWINGS DURING CONSTRUCTION SHALL BE APPROVED IN WRITING BY THE CITY OF
WAUKEE DEVELOPMENT SERVICES DEPARTMENT PRIOR TO CONSTRUCTION.
U. THE CONTRACTOR IS RESPONSIBLE FOR ANY CHANGES MADE DURING CONSTRUCTION THAT HAVE NOT BEEN GRANTED
APPROVAL IN WRITING BY THE CITY OF WAUKEE DEVELOPMENT SERVICES DEPARTMENT.
V. ALL SANITARY SEWER AND STORM SEWER SHALL BE CLEANED AND TELEVISED PRIOR TO PAVING. THE CITY OF WAUKEE
SHALL WITNESS ALL CLEANING AND TELEVISING. COPIES OF THE REPORT AND VIDEO SHALL BE PROVIDED TO THE CITY OF
WAUKEE. ALL SANITARY SEWER MANHOLES SHALL BE VACUUM TESTED.
W. PLACE 3/4" EXPANSION JOINT BETWEEN ALL PCC PAVEMENT/SIDEWALKS AND BUILDINGS. PLACE 1/2" EXPANSION JOINT
BETWEEN SIDEWALKS AND PCC PAVEMENT. THE PCC RAMP JOINT LOCATED AT THE BACK OF CURB AND ALL EXPANSION JOINTS
SHALL BE SEALED.
X. AS-BUILTS SHALL BE PROVIDED TO THE WAUKEE ENGINEERING DEPARTMENT INCLUDING ALL UTILITIES AND AS-BUILT
GRADES FOR DRAINAGE SWALES, OVERFLOWS, ACCESSIBLE RAMPS AND DETENTION FACILITIES. THE CONTRACTOR SHALL
PROVIDE INFORMATION TO THE DESIGN ENGINEER FOR INCLUSION ON THE RECORD AS-BUILT DRAWINGS.
Y. ALL UTILITIES INCLUDING PRIVATE UTILITIES SHALL BE CONSTRUCTED TO THE CITY OF WAUKEE STANDARD SPECIFICATIONS
FOR PUBLIC IMPROVEMENTS AND ALL UTILITIES SHALL BE TESTED TO CITY STANDARDS. THE CITY SHALL WITNESS ALL TESTING.
Z. CONSTRUCTION OPERATIONS SHALL PROTECT STORM SEWERS AND DRAINAGE WAYS FROM ALLOWING CONCRETE SLURRY
FROM CONCRETE OPERATIONS TO DISCHARGE OFFSITE.
AA. CONTRACTOR SHALL COORDINATE ALL TIE-IN TO UTILITIES WITH THE CITY OF WAUKEE ENGINEERING DEPARTMENT AND
CITY OF WAUKEE ENGINEERING DEPARTMENT SHALL WITNESS ALL TIE-INS.
BB. ALL FIRE HYDRANTS WILL BE REQUIRED TO HAVE 5-INCH STORZ FITTINGS.
CC. CONTRACTOR IS TO PROVIDE SHOP DRAWING SUBMITTALS OF CONSTRUCTION MATERIALS PRIOR TO CONSTRUCTION.
DD. PRIOR TO ANY LANE CLOSURE THE CONTRACTOR IS RESPONSIBLE FOR HAVING A DIGITAL MESSAGE BOARD NOTIFYING
DRIVERS OF LANE CLOSURES AT LEAST ONE WEEK PRIOR TO ANY CLOSURE. CONTRACTOR IS TO COORDINATE ANY LANE/ROAD
CLOSURES WITH THE CITY OF WAUKEE.
EE. APPROVED FIRE APPARATUS ACCESS ROADS SHALL BE PROVIDED FOR EVERY FACILITY, BUILDING, OR PORTION OF A
BUILDING AS SOON AS CONSTRUCTION COMMENCES. THE FIRE APPARATUS ACCESS ROAD SHALL COMPLY WITH THE
REQUIREMENTS OF SECTION 503.2 AND THIS SECTION SHALL EXTEND TO WITHIN 100 FEET OF ALL PORTIONS OF THE EXTERIOR
WALLS OF THE FIRST STORY OF THE BUILDING AS MEASURED BY AN APPROVED ROUTE AROUND THE EXTERIOR OF THE
BUILDING OR FACILITY.
FF. ALL SIGNAGE REQUIRES A SEPARATE PERMIT FROM THE CITY OF WAUKEE DEVELOPMENT SERVICES DEPARTMENT.
POLLUTION PREVENTION NOTES
A.POLLUTION PREVENTION AND EROSION PROTECTION
1.CODE COMPLIANCE: THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL
POTENTIAL POLLUTION AND SOIL EROSION CONTROL REQUIREMENTS OF THE IOWA CODE,
THE IOWA DEPARTMENT OF NATURAL RESOURCES (IDNR) NPDES PERMIT, THE U.S. CLEAN
WATER ACT AND ANY LOCAL ORDINANCES. THE CONTRACTOR SHALL TAKE ALL NECESSARY
STEPS TO PROTECT AGAINST EROSION AND POLLUTION FROM THIS PROJECT SITE AND ALL
OFF-SITE BORROW OR DEPOSIT AREAS DURING PERFORMANCE OR AS A RESULT OF
PERFORMANCE.
2.DAMAGE CLAIMS: THE CONTRACTOR WILL HOLD THE OWNER AND ARCHITECT / ENGINEER
HARMLESS FROM ANY AND ALL CLAIMS OF ANY TYPE WHATSOEVER RESULTING FROM
DAMAGES TO ADJOINING PUBLIC OR PRIVATE PROPERTY, INCLUDING REASONABLE
ATTORNEY FEES INCURRED TO OWNER. FURTHER, IF THE CONTRACTOR FAILS TO TAKE
NECESSARY STEPS TO PROMPTLY REMOVE EARTH SEDIMENTATION OR DEBRIS WHICH
COMES ONTO ADJOINING PUBLIC OR PRIVATE PROPERTY, THE OWNER MAY, BUT NEED NOT,
REMOVE SUCH ITEMS AND DEDUCT THE COST THEREOF FROM AMOUNTS DUE TO THE
CONTRACTOR.
B.STORM WATER DISCHARGE PERMIT
1.THIS PROJECT REQUIRES COVERAGE UNDER THE NPDES GENERAL PERMIT NO. 2 FOR
STORM WATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITIES FROM THE
IDNR, AS REQUIRED BY THE ENVIRONMENTAL PROTECTION AGENCY (EPA). THE GENERAL
CONTRACTOR AND ALL SUBCONTRACTORS ARE RESPONSIBLE FOR COMPLIANCE WITH AND
FULFILLMENT OF ALL REQUIREMENTS OF THE NPDES GENERAL PERMIT NO. 2 AS SPECIFIED
IN THE CONTRACT DOCUMENTS.
2.ALL DOCUMENTS RELATED TO THE STORM WATER DISCHARGE PERMIT, INCLUDING, BUT
NOT LIMITED TO, THE NOTICE OF INTENT, PROOF OF PUBLICATIONS, DISCHARGE
AUTHORIZATION LETTER, CURRENT SWPPP, SITE INSPECTION LOG, AND OTHER ITEMS,
SHALL BE KEPT ON SITE AT ALL TIMES AND MUST BE PRESENTED TO ANY JURISDICTIONAL
AGENCIES UPON REQUEST. FAILURE TO COMPLY WITH THE NPDES PERMIT REQUIREMENTS
IS A VIOLATION OF THE CLEAN WATER ACT AND THE CODE OF IOWA.
3.A "NOTICE OF DISCONTINUATION" MUST BE FILED WITH THE IDNR UPON FINAL
STABILIZATION OF THE DISTURBED SITE AND REMOVAL OF ALL TEMPORARY EROSION
CONTROL MEASURES. ALL PLANS, INSPECTION REPORTS, AND OTHER DOCUMENTS MUST
BE RETAINED FOR A PERIOD OF THREE YEARS AFTER PROJECT COMPLETION. THE
CONTRACTOR SHALL RETAIN A RECORD COPY AND PROVIDE THE ORIGINAL DOCUMENTS
TO THE OWNER UPON PROJECT ACCEPTANCE AND/OR SUBMITTAL OF THE NOTICE OF
DISCONTINUATION.
C.POLLUTION PREVENTION PLAN
1.THE STORM WATER POLLUTION PREVENTION PLAN (SWPPP) IS A SEPARATE DOCUMENT IN
ADDITION TO THESE PLAN DRAWINGS. THE CONTRACTOR SHOULD REFER TO THE SWPPP
FOR ADDITIONAL REQUIREMENTS AND MODIFICATIONS TO THE POLLUTION PREVENTION
PLAN MADE DURING CONSTRUCTION.
2.THE SWPPP ILLUSTRATES GENERAL MEASURES AND BEST MANAGEMENT PRACTICES (BMP)
FOR COMPLIANCE WITH THE PROJECT'S NPDES PERMIT COVERAGE. ALL BMP'S AND
EROSION CONTROL MEASURES REQUIRED AS A RESULT OF CONSTRUCTION ACTIVITIES
ARE THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY, NOTE AND IMPLEMENT.
ADDITIONAL BMP'S FROM THOSE SHOWN ON THE PLAN MAY BE REQUIRED.
3.THE SWPPP AND SITE MAP SHOULD BE EXPEDITIOUSLY REVISED TO REFLECT
CONSTRUCTION PROGRESS AND CHANGES AT THE PROJECT SITE.
4.THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL REQUIREMENTS OF THE
GENERAL PERMIT AND SWPPP, INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING BMP'S
UNLESS INFEASIBLE OR NOT APPLICABLE:
a.UTILIZE OUTLET STRUCTURES THAT WITHDRAW WATER FROM THE SURFACE WHEN
DISCHARGING FROM BASINS, PROVIDE AND MAINTAIN NATURAL BUFFERS AROUND
SURFACE WATERS, DIRECT STORM WATER TO VEGETATED AREAS TO INCREASE
SEDIMENT REMOVAL AND MAXIMIZE STORM WATER INFILTRATION, AND MINIMIZE SOIL
COMPACTION.
b.INSTALL PERIMETER AND FINAL SEDIMENT CONTROL MEASURES SUCH AS SILT
BARRIERS, DITCH CHECKS, DIVERSION BERMS, OR SEDIMENTATION BASINS
DOWNSTREAM OF SOIL DISTURBING ACTIVITIES PRIOR TO SITE CLEARING AND GRADING
OPERATIONS.
c.PRESERVE EXISTING VEGETATION IN AREAS NOT NEEDED FOR CONSTRUCTION AND
LIMIT TO A MINIMUM THE TOTAL AREA DISTURBED BY CONSTRUCTION OPERATIONS AT
ANY TIME.
d.MAINTAIN ALL TEMPORARY AND PERMANENT EROSION CONTROL MEASURES IN
WORKING ORDER, INCLUDING CLEANING, REPAIRING, REPLACEMENT, AND SEDIMENT
REMOVAL THROUGHOUT THE PERMIT PERIOD. CLEAN OR REPLACE SILT CONTROL
DEVICES WHEN THE MEASURES HAVE LOST 50% OF THEIR ORIGINAL CAPACITY.
e.INSPECT THE PROJECT AREA AND CONTROL DEVICES (BY QUALIFIED PERSONNEL
ASSIGNED BY THE CONTRACTOR) EVERY SEVEN CALENDAR DAYS. RECORD THE
FINDINGS OF THESE INSPECTIONS AND ANY RESULTING ACTIONS IN THE SWPPP WITH A
COPY SUBMITTED WEEKLY TO THE OWNER OR ENGINEER DURING CONSTRUCTION.
REVISE THE SWPPP AND IMPLEMENT ANY RECOMMENDED MEASURES WITHIN 7 DAYS.
f.PREVENT ACCUMULATION OF EARTH AND DEBRIS FROM CONSTRUCTION ACTIVITIES ON
ADJOINING PUBLIC OR PRIVATE PROPERTIES, INCLUDING STREETS, DRIVEWAYS,
SIDEWALKS, DRAINAGEWAYS, OR UNDERGROUND SEWERS. REMOVE ANY
ACCUMULATION OF EARTH OR DEBRIS IMMEDIATELY AND TAKE REMEDIAL ACTIONS FOR
FUTURE PREVENTION.
g.INSTALL NECESSARY CONTROL MEASURES SUCH AS SILT BARRIERS, EROSION CONTROL
MATS, MULCH, DITCH CHECKS OR RIPRAP AS SOON AS AREAS REACH THEIR FINAL
GRADES AND AS CONSTRUCTION OPERATIONS PROGRESS TO ENSURE CONTINUOUS
RUNOFF CONTROL. PROVIDE INLET AND OUTLET CONTROL MEASURES AS SOON AS
STORM SEWERS ARE INSTALLED.
h.RESPREAD A MINIMUM OF 8 INCHES OF TOPSOIL (INCLUDING TOPSOIL FOUND IN SOD) ON
ALL DISTURBED AREAS, EXCEPT WHERE PAVEMENT, BUILDINGS OR OTHER
IMPROVEMENTS ARE LOCATED.
i.STABILIZE UNDEVELOPED, DISTURBED AREAS WITH MULCH, TEMPORARY SEED MIX,
PERMANENT SEED MIX, SOD, OR PAVEMENT IMMEDIATELY AS SOON AS POSSIBLE UPON
COMPLETION OR DELAY OF GRADING OPERATIONS. INITIATE STABILIZATION MEASURES
IMMEDIATELY AFTER CONSTRUCTION ACTIVITY IS FINALLY COMPLETED OR
TEMPORARILY CEASED ON ANY PORTION OF THE SITE AND WHICH WILL NOT RESUME
FOR A PERIOD EXCEEDING 14 CALENDAR DAYS.
j.COORDINATE LOCATIONS OF STAGING AREAS WITH THE OWNER AND RECORD IN THE
SWPPP. UNLESS NOTED OTHERWISE, STAGING AREAS SHOULD CONTAIN THE
FOLLOWING: JOB TRAILERS, FUELING / VEHICLE MAINTENANCE AREA, TEMPORARY
SANITARY FACILITIES, MATERIALS STORAGE, AND CONCRETE WASHOUT FACILITY.
CONTROL RUNOFF FROM STAGING AREAS WITH DIVERSION BERMS AND/OR SILT
BARRIERS AND DIRECT TO A SEDIMENT BASIN OR OTHER CONTROL DEVICE WHERE
POSSIBLE. CONCRETE WASHOUT MUST BE CONTAINED ONSITE.
k.REMOVE ALL TEMPORARY EROSION CONTROL MEASURES AND SITE WASTE PRIOR TO
FILING OF THE "NOTICE OF DISCONTINUATION".
S89°57'41"W 200.00'N0°02'19"W 333.52'N89°57'41"E 200.00'S0°02'19"E 333.52'
15' P.U.E.
Bk 798, Pg 366-382
15' Drainage Easement
Bk 798, Pg 366-382
40' Building Setback30' Building Setback30' Building SetbackBM500BM501 2 3 4ConcreteNE VENTURE DRIVEF.L.=1019.25 15" RCP SE
Rim=1024.34
F.L.=1007.61 8" Truss E&W
Rim=1023.17
Intake=1022.41
F.L.=1016.15 18" RCP W
F.L.=1016.21 15" RCP S
Rim=1021.83
Intake=1021.04
F.L.=1015.29 18" RCP E&W
F.L.=1016.63 12" RCP NW
For Sale Sign5.5'20.0' B/B
5.0'
260.0'8.0'
25.0' B/B10.0'26.0'19.0'90.0'19.0'26.0'10.0'26.0' TYP45.0' TYP6.0'
TYP
10.0'
TYP
10.0'
TYP
6.0'
TYP
10.0'
TYP
R25.0R25.0R4.0R29.
0
R
4
.
0
R29
.0
R20.0
R2
5
.
025.0' B/B10.0'
TYP
TYP
TYPTYP
TYPTYP
TYP TYP
PROPOSED BUILDING
23,400 SF
TYPTYP
TYP TYP T5.0'
5.0'5.0'31.0' B/B
5.0'WAUKEE COMMUNITY CHURCHM-1 LIGHT INDUSTRIAL DISTRICTIT'S A RU
F
F
L
I
F
E
-
D
O
G
G
Y
D
A
Y
C
A
R
E
,
L
L
C
C-1 COMM
U
N
I
T
Y
A
N
D
H
I
G
H
W
A
Y
S
E
R
V
I
C
E
COMMERC
I
A
L
D
I
S
T
R
I
C
T
1500 C
L
I
V
E
L
L
C
M-1 LIG
H
T
I
N
D
U
S
T
R
I
A
L
D
I
S
T
R
I
C
T
DOWNIN
G
D
E
V
E
L
O
P
M
E
N
T
,
L
T
D
M-1 LIGH
T
I
N
D
U
S
T
R
I
A
L
D
I
S
T
R
I
C
T
50.0' 1/2 ROW
R5.0'R1.0'R5.0'R1.0'1A
1A
1A
1B
1B
1B
1B
1A
1A
1C
1C1C1C
1C
1C
1C
1A
1C
1C
1B
1B
2A
3B
3B
3B
3B
4C 4C
4D 4D
4D4D
4B 4B 4A4A
4A 4A
5A5A
9F
3A
3A
3C
3C
3C
3C
3D
3D
3D
3D3D
3D
3E
3E
3E
3E
9H
2A
9A
9G
9E
79D
8B 8A
9B 9G
8D
8C
11111111
11 11 11 11
10A10A
10A 10A
12E
12D
3F
3F
3D
1A
3G
3G
7
5B
9C
9J
9J BP:1015.72 (ST)
TP:1013.62 (W)
BP:1016.74 (W)
TP:1008.71 (SAN)
9C7
8A INV: 1016.48
(VERIFY)4" PCC
4" PCC
9I
9K
9L
15.5'9.9'12B
12F
INV: 1019.7512G
3H
3H
5C
5C BYDATEREVISIONMARKScale:Technician:T-R-S:SNYDER & ASSOCIATES, INC. |Checked By:Engineer:Date:1" =Project No:SheetProject No:
Sheet 5010 VOGES ROADMADISON. WISCONSIN 53718608-838-0444 | www.snyder-associates.comEDCRMBKMM07/19/202120'121.0643C200121.0643
C200LOT 5, ENTERPRISE BUSINESS PARK PLAT 1DIMENSION AND UTILITY PLANWAUKEE, IOWAAS PER CITY COMMENTSAS PER CITY COMMENTS 08/17/2108/31/21 JRCJRC 12 TTN-RRW-SSV:\Projects\2021\121.0643.01\CADD\SP_1210643_DIMS.dwg JAKE R. CAMPOS, DIMENSION AND UTILITY PLAN, 2021/08/31, 8:14 AM, ANSI FULL BLEED D (34.00 X 22.00 INCHES)FEET
0 20
DIMENSION PLAN CONSTRUCTION NOTES
1. EXISTING FEATURES, PROTECT THE FOLLOWING:
A.PAVEMENT TO REMAIN.
B.EXISTING UTILITIES. COORDINATE ANY RELOCATIONS OR ADJUSTMENTS WITH
UTILITY SERVICE PROVIDER AS NECESSARY.
C.EXISTING TREES.
2.DRIVEWAY:
A.GRIND CURB AND CONSTRUCT TYPE "A" DRIVEWAY CONNECTION TO EXISTING
PRIVATE DRIVE.
3.PAVEMENTS, PROVIDE THE FOLLOWING WHERE INDICATED ON PLAN:
A.6" DEPTH PCC DRIVE AND PARKING.
B.7" DEPTH PCC PAVEMENT.
C.3" ROLLED CURB.
D.6" HEIGHT STANDARD CURB.
E.TAPER CURB IN 3 FEET.
F.4" DEPTH PCC SIDEWALK.
G.TAPER 5' SIDEWALK TO EXISTING IN ONE PANEL.
H.6" PCC PEDESTRIAN RAMP WITH MAX SLOPE OF 8.33%.
4.PAVEMENT MARKINGS, PROVIDE THE FOLLOWING:
A.4" WIDE PAINTED PARKING STALL LINES.
B.PAINTED STATE OF IOWA APPROVED ACCESSIBLE PARKING SYMBOL.
C.ACCESSIBLE AISLE. 45° STRIPING AT 3' ON CENTER SPACING WHERE SHOWN.
D.45° STRIPING AT 3' ON CENTER TO DELINEATE NO PARKING.
5.SIGNS, PROVIDE THE FOLLOWING:
A.PROVIDE VAN ACCESSIBLE PARKING SIGNAGE AS PER ADAAG REQUIREMENTS.
MOUNT SIGN TO BUILDING.
B.MONUMENT SIGN.
C.FIRE LANE SIGN. SEE NOTES ON THIS SHEET FOR DETAILS.
6.SITE LIGHTING, PROVIDE THE FOLLOWING:
A.CONTRACTOR TO COORDINATE WITH THE UTILITY OWNER AND PROPERTY
OWNER ALL ASPECTS OF ELECTRICAL SERVICE.
B.WALL MOUNTED LIGHT. REFER TO BUILDING ELECTRICAL PLANS.
7.CONTRACTOR TO VERIFY ALL UTILITY CROSSINGS AND MAINTAIN A MINIMUM OF 18"
OF CLEARANCE BETWEEN UTILITIES.
8.SANITARY SEWER SERVICE, PROVIDE AND INSTALL THE FOLLOWING:
A.CONNECT TO EXISTING SANITARY SEWER STUB. VERIFY LOCATION AND
ELEVATION PRIOR TO CONSTRUCTION.
B.6" PVC SANITARY SEWER SERVICE LINE AT 1.0% MIN SLOPE (1/8" PER FOOT).
PROVIDE 1:1 RISER AS NECESSARY.
C.COORDINATE THE EXACT LOCATION AND DEPTH WHERE SANITARY SEWER
SERVICE LINE ENTERS THE BUILDING WITH THE ARCHITECTURAL AND
MECHANICAL PLANS PRIOR TO CONSTRUCTION.
D.SANITARY SEWER CLEANOUT. PROVIDE MANHOLE CASTING NEENAH R-1976
WHEN IN PAVEMENT.
9.WATER SERVICE FROM CITY OF WAUKEE, PROVIDE THE FOLLOWING AS PER CITY
REQUIREMENTS AND GUIDELINES:
A.CONNECTION TO EXISTING WATER MAIN W/ TAPPING SLEEVE AND VALVE.
COORDINATE WITH THE CITY OF WAUKEE WATER DEPARTMENT FOR EXACT
LOCATION TO KEEP SEPARATION FROM EXISTING SERVICE.
B.2" DOMESTIC WATER SERVICE LINE.
C.REMOVE 2" CURB SHUT OFF VALVE AND ABANDON 2" SERVICE IN PLACE.
DISCONNECT 2" WATER SERVICE AT MAIN. REMOVE CORP AND INSTALL SOLID
SLEEVE.
D.COORDINATE THE EXACT LOCATION, SIZE AND ELEVATION WHERE WATER
SERVICE LINE ENTERS THE BUILDING WITH THE ARCHITECTURAL AND
MECHANICAL PLANS PRIOR TO CONSTRUCTION.
E.FIRE HYDRANT ASSEMBLY.
F.FIRE DEPARTMENT CONNECTION WITH LOCKING KNOX CAPS.
G.6" WATER SERVICE.
H.DIRECTIONAL DRILL 6" WATER SERVICE.
I.6"x6" TEE.
J.CRITICAL CROSSING. CONTRACTOR TO VERIFY EXACT DEPTH, LOCATION AND
SIZE OF EXISTING UTILITIES PRIOR TO CONSTRUCTION. COORDINATE ANY
RELOCATIONS OF EXISTING UTILITIES WITH UTILITY PROVIDER, OWNER AND
CITY OF WAUKEE PRIOR TO CONSTRUCTION. MAINTAIN 18" OF VERTICAL
SEPARATION BETWEEN UTILITIES.
K.6" SHUT OFF VALVE.
L.2" SHUT OFF VALVE.
10.DOORS
A.AT-GRADE 12' WIDE OVERHEAD ENTRANCE DOOR.
11.BUILDING DOWNSPOUT LOCATION. VERIFY WITH ARCHITECTURAL PLANS.
CONTRACTOR TO COORDINATE DOWNSPOUT CONNECTION PRIOR TO
CONSTRUCTION.
12.UTILITY SERVICE. COORDINATE WITH ARCHITECTURAL AND MECHANICAL PLANS.
A.GAS SERVICE.
B.GAS METER.
C.ELECTRIC SERVICE.
D.TRANSFORMER.
E.FIRE RISER ROOM.
F.ELECTRICAL METER.
G.ROOF ACCESS LADDER.
FORM
GRADE
ELEV.
2
C200
6-INCH STANDARD CURB
NO SCALE 6"SLOPE AS
PER PLANS
4 1
2"
7 1
2"
R3"
R3"
3
C200
3-INCH ROLLED CURB
NO SCALE
2 1
2"
10 1
2"3"7"FINISHED GRADE
OR SIDEWALK
(SEE PLAN)
3" DROP CURB
2"R
1"R
PAVEMENT LEGEND
7" PCC PAVEMENT
6" PCC PAVEMENT
4" PCC PAVEMENT
1
C200
DOWNSPOUT CONNECTION DETAIL
NO SCALE
NOTES:
CONTRACTOR IS RESPONSIBLE
FOR CONNECTING ROOF DRAIN TO
INTAKES. SEE PLANS FOR ALL
INVERTS.
BUILDING
BUILDING
12"4"12"4"DOWNSPOUT.
SEE ARCHITECTURAL PLANS
12" PVC
PERIMETER
SEALANT AT
JOINT
DOWNSPOUT
12" CAP WITH 8"
SQUARE CUT O.C.
TO STORM SEWER
FIRE LANE SIGN NOTES
1.FIRE LANE SIGN SHALL BE 18" TALL X 12" WIDE WITH RED LETTERS ON A WHITE
REFLECTIVE BACKGROUND TO READ "FIRE LANE - NO PARKING EXCEPT
EMERGENCY VEHICLES".
2.FIRE LANE SIGNS SHALL BE PLACED BETWEEN 2-FEET AND 4-FEET FROM THE EDGE
OF THE FIRE LANE.
3.ALL SIGNS SHALL BE SET AT AN ANGLE OF NOT LESS THAN 30 DEGREES AND NOT
MORE THAN 45 DEGREES WITH THE LINE OF TRAFFIC FLOW.
4.SIGNS IN OPEN SPACE SHALL BE MOUNTED BETWEEN 5-FEET AND 7-FEET FROM
THE FINISHED GROUND GRADE TO THE BOTTOM OF THE SIGN.
5.FIRE LANES SHALL BE STRIPED IN RED ALONG THE ENTIRE LENGTH OF THE FIRE
LANE.
6.VERTICAL CURBS SHALL BE PAINTED RED ON THE TOP AND SIDE.
7.THE WORDS "NO PARKING - FIRE LANE" SHALL BE STENCILED WITH 3" TALL WHITE
LETTERS AND A MINIMUM 3/4" STROKE ON THE VERTICAL FACE OF CURBING. THE
STENCILING SHALL BE SPACED AT FIFTY FOOT INTERVALS ALONG THE ENTIRE FIRE
LANE LENGTH.
4
C200
WAUKEE STD.DWG.NO.53
NO SCALE
T15' P.U.E.
Bk 798, Pg 366-382
15' Drainage Easement
Bk 798, Pg 366-382
40' Building Setback30' Building Setback30' Building SetbackPROPOSED BUILDING
23,400 SF
FFE = 1024.75
BM500BM501 1 2 3 4 5102210231
0
2
4
1024102410251026102310101015102010241
0
2
2
10
2
3
10
2
4
1025
1024
102310241025
10251026
10
2
5
1026
1026 102610251023
ConcreteNE VENTURE DRIVEIntake=1022.45
F.L.=1016.55 15" RCP N
F.L.=1019.25 15" RCP SE
Rim=1024.34
F.L.=1007.61 8" Truss E&W
Rim=1022.43
Bottom of Well=1021.40
F.L.=1021.63 4" PVC W
F.L.=1021.71 4" PVC E
Rim=1023.17
Intake=1022.41
F.L.=1016.15 18" RCP W
F.L.=1016.21 15" RCP S
Rim=1021.83
Intake=1021.04
F.L.=1015.29 18" RCP E&W
F.L.=1016.63 12" RCP NW1024For Sale Sign
Rip Rap
Rip Rap10231023
1022128 LF OF 12" RCP @ 0.51%
128 LF OF 15" RCP @ 0.51%
75 LF OF 15" RCP @ 3.16%
127 LF OF 12" RCP @ 0.51%
128 LF OF 15" RCP @ 0.51%
222 LF OF 15" RCP @ 1.61%
ST-7B, 18'' FES W/ FOOTING
INV: 1010.25
ST-7, SW-501, Single Grate Intake
T/C: 1024.10
INV: 1019.10 (IN S)
INV: 1019.10 (IN W)
INV: 1019.00 (OUT N)
ST-5, SW-501, Single Grate Intake
T/C: 1024.10
INV: 1019.85 (IN S)
INV: 1019.75 (OUT N)
ST-4, SW-501, Single Grate Intake
T/C: 1024.10
INV: 1020.50 (OUT N)
ST-3, SW-501, Single Grate Intake
T/C: 1024.10
INV: 1019.10 (IN N)
INV: 1019.00 (OUT S)
ST-2, SW-501, Single Grate Intake
T/C: 1024.10
INV: 1019.85 (IN N)
INV: 1019.75 (OUT S)
ST-1, SW-501, Single Grate Intake
T/C: 1024.10
INV: 1020.50 (OUT S)
93 LF OF 12" RCP @ 1.00%
ST-6, SW-501, Single Grate Intake
T/C: 1024.25
INV: 1020.03 (OUT E)
ST-7A, SW-401, Circular Storm Sewer Manhole
RIM: 1020.00
INV: 1015.43 S
INV: 1010.43 N
36 LF OF 18" RCP @ 0.50%
CRITICAL
CROSSING:
BP = 1017.12 ST
TP = 1007.62 SAN
CRITICAL CROSSING:
BP = 1021.50 ST
TP = 1017.37 ST ○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
20' STORM
SEWER EASEMENT
(TO BE RECORDED IN
SEPARATE DOCUMENT)
15' DRAINAGE EASEMENT
BK 798, Pg 366-382
100' STORM WATER & SURFACE
WATER FLOWAGE EASEMENT
BK 798, PG 366-382
CONNECT TO EXISTING:
INV.=1016.63 BYDATEREVISIONMARKScale:Technician:T-R-S:SNYDER & ASSOCIATES, INC. |Checked By:Engineer:Date:1" =Project No:SheetProject No:
Sheet 2727 S.W. SNYDER BLVDANKENY, IOWA 50023515-964-2020 | www.snyder-associates.comEDCRMBKMM07/19/202130'121.0643C300121.0643
C300LOT 5, ENTERPRISE BUSINESS PARK PLAT 1STORM SEWER PLANWAUKEE, IOWAAS PER CITY COMMENTSAS PER CITY COMMENTS 08/17/2108/31/21 JRCJRC 12 TTN-RRW-SSV:\Projects\2021\121.0643.01\CADD\SP_1210643_STRM.dwg JAKE R. CAMPOS, STORM SEWER PLAN, 2021/08/31, 8:15 AM, ANSI FULL BLEED D (34.00 X 22.00 INCHES)FEET
0 30
BENCHMARKS
NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88 - GEOID12A)
IARTN DERIVED - US SURVEY FEET
BM500 N=589408.86 E=1538878.09 ELEV=1024.43
TRIANGLE AT SOUTHEAST CORNER OF CONCRETE
TRANSFORMER PAD, WEST SIDE OF SITE.
BM501 N=589128.26 E=1538972.05 ELEV=1023.97
BURY BOLT ON HYDRANT ON THE SOUTH SIDE OF VENTURE
DRIVE SOUTH OF FOR SALE SIGN, SOUTH SIDE OF SITE.
T15' P.U.E.
Bk 798, Pg 366-382
15' Drainage Easement
Bk 798, Pg 366-382
40' Building Setback30' Building Setback30' Building SetbackPROPOSED BUILDING
23,400 SF
FFE = 1024.75
BM500BM501 1 2 3 4 5102210231
0
2
4
1024102410251026102310101015102010241
0
2
2
10
2
3
10
2
4
1025
1024
102310241025
10251026
10
2
5
1026
1026 102610251023
ConcreteNE VENTURE DRIVEIntake=1022.45
F.L.=1016.55 15" RCP N
F.L.=1019.25 15" RCP SE
Rim=1024.34
F.L.=1007.61 8" Truss E&W
Rim=1022.43
Bottom of Well=1021.40
F.L.=1021.63 4" PVC W
F.L.=1021.71 4" PVC E
Rim=1023.17
Intake=1022.41
F.L.=1016.15 18" RCP W
F.L.=1016.21 15" RCP S
Rim=1021.83
Intake=1021.04
F.L.=1015.29 18" RCP E&W
F.L.=1016.63 12" RCP NW1024For Sale Sign
Rip Rap
Rip Rap10231023
10221024.10 TC
1023.60 G
1024.75 TC1024.25 G
102
4.
7
5
T
C
102
4.
2
5
G
1024.10 TC1023.60 G
1
0
2
4
.
1
0
T
C
1
0
2
3
.
6
0
G
1
0
2
4
.
7
5
T
C
1
0
2
4
.
2
5
G
1
0
2
4
.
1
0
T
C
1
0
2
3
.
6
0
G
1
0
2
4
.
7
5
T
C
1
0
2
4
.
2
5
G
1024.10 TC
1023.60 G
1024.35
FFE=1024.75
1024.25
1024.25
1024.25 TC
1024.00 G
1024.25
102
4
.
2
5
1024.35
FFE=1024.75
1023.98
1023.98
1024.30
1024.25
1024.251024.50 TC
1024.25 G
1024.25
1024.25
1
0
2
4
.
3
0
FFE=1024.75
FFE=1024.75
1024.25
1024.25
(1022.04)(1022.59)(1021.90)1023.611024.541024.54
1024.54
1
0
2
4
.
5
4
1024.10 TC1023.60 G1024.25 TC
1023.75 G
1023.21
1024.77
SEDIMENT
BASKET
SEDIMENT
BASKET
SEDIMENT
BASKET
SEDIMENT
BASKET
SEDIMENT
BASKET SEDIMENT
BASKET
SEDIMENT
BASKET
STABILIZED
CONSTRUCTION
ENTRANCE○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
SILT FENCE (TYP.)
STAGING
AREA1024
1
0
2
4
1024
1024102310221024
1024
10241024
1025 1025
1024
1023102410261026
1024FFE=1024.75
(1022.29)
FFE=1024.75
FFE=1024.75
(1024.09)
FFE=1024.75
100-YEAR
ELV.=1023.79'100-YEAR
ELV.=1023.84'
100-YEAR ELV.
1023.66'
100-YEAR
ELV.=1023.79'
100-YEAR
ELV.=1023.83'
100-YEAR
ELV.=1023.63'
SEDIMENT
BASKET
SEDIMENT
BASKET
LIMIT OF DISTURBANCE
CONCRETE WASHOUT
AND WASTE MATERIALS
TOPSOIL
STOCKPILE○ULTIMATE DISCHARGE TO
LITTLE WALNUT CREEK
○○○○○○○○○○SILT FENCE (TYP.)○○
NORMAL POOL: 1010.25
100-YR: 1016.00
-2.
0
5
%-2.05%-3.12%
-3.12%
20' STORM
SEWER EASEMENT
(TO BE RECORDED IN
SEPARATE DOCUMENT)
15' DRAINAGE EASEMENT
BK 798, Pg 366-382
10 TONS CLASS D RIP RAP
10'L X 10'W X 1.5'D
OVERFLOW
@1024.25
OVERFLOW
@1024.25
OVERFLOW@1024.25OVERFLOW@1024.25OVERFLOW
@1024.25OVERFLOW
@1024.25OVERFLOW@1024.25
OVE
RFL
O
W
@1024.25
100-YEAR
ELV.=1023.25'
1023.34
1023.40
1023.20
1023.081023.56
1023.69
1023.50
1023.451023.50
1023.55 1023.43 1023.93
1023.32 1023.81
1023.85 1023.90
1023.951023.90
-1.00%-1.00%-1.00%-1.00%-4.22%
-3.64%
1023.16
1023.16
1023.10 1023.43
-5.37%-1.00%-6.21%
-1.00%
-1.00%-1.00%-1.50%0.03%0.59%1023
10
2
3
1024.54
1024.54 1024.75
1024.75
1024.54 1024.75
1.11%0.00%-0.00%BYDATEREVISIONMARKScale:Technician:T-R-S:SNYDER & ASSOCIATES, INC. |Checked By:Engineer:Date:1" =Project No:SheetProject No:
Sheet 2727 S.W. SNYDER BLVDANKENY, IOWA 50023515-964-2020 | www.snyder-associates.comEDCRMBKMM07/19/202130'121.0643C400121.0643
C400LOT 5, ENTERPRISE BUSINESS PARK PLAT 1GRADING AND EROSION CONTROL PLANWAUKEE, IOWAAS PER CITY COMMENTSAS PER CITY COMMENTS 08/17/2108/31/21 JRCJRC 12 TTN-RRW-SSV:\Projects\2021\121.0643.01\CADD\SP_1210643_GRDG.dwg JAKE R. CAMPOS, GRADING AND EROSION CONTROL PLAN, 2021/08/31, 8:15 AM, ANSI FULL BLEED D (34.00 X 22.00 INCHES)FEET
0 30
GRADING PLAN CONSTRUCTION NOTES
A.CONTRACTOR TO STRIP AND STOCKPILE TOPSOIL ON ALL AREAS TO BE
CUT OR FILLED. RESPREAD TO MINIMUM 8" DEPTH TO FINISH GRADES.
B.ANY EXCESS CUT TO BE SPREAD ON SITE AS DIRECTED BY ENGINEER
DURING CONSTRUCTION. PLACE TOPSOIL OVER ALL AREAS
DISTURBED.
C.ALL DRAINAGE SWALES AND SLOPES 5 TO 1 OR GREATER TO BE
SEEDED USING COMMERCIALLY AVAILABLE EROSION CONTROL SEED
(SUDAS TYPE 4). MIXTURE APPLIED AT RATE RECOMMENDED BY
SUPPLIER.
D.EROSION CONTROL: SEED THE SITE AFTER ROUGH GRADING HAS
BEEN COMPLETED. PLACE SILT FENCE AND MAINTAIN IN PROBLEM
AREAS AFTER GROUND COVER HAS BEEN ESTABLISHED. COMPLY
WITH EROSION CONTROL LAW.
E.PROVIDE BELOW GRADE INLET PROTECTION IN PAVED AREAS
FOLLOWING PAVING OPERATIONS.
QUANITIES
TEMPORARY SEEDING AND MULCHING (SUDAS TYPE 4) 1.53 AC.
OFF-SITE SEEDING (SUDAS TYPE 1)0.24 AC
SILT FENCE 1,285 LF.
SEDIMENT BASKET 9 EA.
SOD 0.26 AC
DISTURBED AREA
AREA 1.75 AC.
BENCHMARKS
NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88 - GEOID12A)
IARTN DERIVED - US SURVEY FEET
BM500 N=589408.86 E=1538878.09 ELEV=1024.43
TRIANGLE AT SOUTHEAST CORNER OF CONCRETE
TRANSFORMER PAD, WEST SIDE OF SITE.
BM501 N=589128.26 E=1538972.05 ELEV=1023.97
BURY BOLT ON HYDRANT ON THE SOUTH SIDE OF VENTURE
DRIVE SOUTH OF FOR SALE SIGN, SOUTH SIDE OF SITE.
DETAILS OF SILT FENCE ON LONGITUDINAL SLOPES
ATTACHMENT TO POST
TYPICAL SILT FENCE DITCH CHECK
FLOW
BAC
K
SL
O
P
E
FOR
E
S
L
O
P
E
1
1
2
TYPICAL SILT FENCE ISTALLATION ON LONGITUDINAL SLOPES
(Profile View)
TYPICAL SILT FENCE ISTALLATION ON LONGITUDINAL SLOPES
(Plan View)
1
C400
SILT FENCE DETAIL
NO SCALE
1 INSERT 12 INCHES OF FABRIC A
MINIMUM OF 6 INCHES DEEP
(FABRIC MAY BE FOLDED
BELOW THE GROUND LINE.
2 REDUCE POST SPACING TO 5'-0"
AT WATER CONCENTRATION
AREAS, OR AS REQUIRED TO
ADEQUATELY SUPPORT FENCE.'T' STEELFENCE POST4'-0" MINSEE PLANS FOR SPACING
200'-0" MAX LENGTH PER SECTION
600'-0" IF SLOPE IS FLATTER THAN 5%36"24"8'-0" SPACING
VARIABLE (20'-0" FOR A NORMAL 10'-0" WIDE DITCH)
POST SPACING
(5'-0" MAX)
POST SPACING
5'-0" MAX)2"MIN20" MINGROUND LINE
FABRIC
GROUND CONTOURS
INSTALL "J-HOOK" AT EACH END OF AN
INDIVIDUAL SECTION OF SILT FENCE
INSTALL PARALLEL TO
GROUND CONTOUR
FABRICGROUND LINE
FABRIC
POST
WIRE OR
CABLE TIES
2
2
FEET
0 5
NE VENTURE DRIVE
T10000.00IRON MARKER FND (5/8IN REBAR WITH YPC ILLEGIBLE(101-FND))10010.00IRON MARKER FND (5/8IN REBAR YPC 10313(101-FND))10020.00IRON MARKER FND (5/8IN REBAR(101-FND))10030.00IRON MARKER FND (5/8IN REBAR(101-FND))10040.00IRON MARKER FND (5/8IN REBAR//LEANING NORTH(101-FND))S89°57'41"W 200.00'N0°02'19"W 333.52'N89°57'41"E 200.00'S0°02'19"E 333.52'
15' P.U.E.
Bk 798, Pg 366-382
15' Drainage Easement
Bk 798, Pg 366-382
40' Building Setback30' Building Setback30' Building SetbackBM500 4102210231
0
2
4
102410241025102610231025
1024
10241025
10251026
10
2
5
1026
1026 102610251023
ConcreteNE VENTURE DRIVERim=1024.34
F.L.=1007.61 8" Truss E&W
1024For Sale Sign 102310222-QR
2-QR
1-GT
1-GT
2-PG
2-PG
3-VL
3-EA
3-VL3-EA
F F F
F F F
G G
E E
E E
10241024
1
0
2
4
10241024
1024
1024 10241024
1023102210241024
5-HY
F
F
H
E
3-HY BYDATEREVISIONMARKScale:Technician:T-R-S:SNYDER & ASSOCIATES, INC. |Checked By:Engineer:Date:1" =Project No:SheetProject No:
Sheet 2727 S.W. SNYDER BLVDANKENY, IOWA 50023515-964-2020 | www.snyder-associates.comEDCRMBKMM07/19/202120'121.0643C500121.0643
C500LOT 5, ENTERPRISE BUSINESS PARK PLAT 1PLANTING PLANWAUKEE, IOWAAS PER CITY COMMENTSAS PER CITY COMMENTS 08/17/2108/31/21 JRCJRC 12 TTN-RRW-SSV:\Projects\2021\121.0643.01\CADD\SP_1210643_LAND.dwg JAKE R. CAMPOS, PLANTING PLAN, 2021/08/31, 8:15 AM, ANSI FULL BLEED D (34.00 X 22.00 INCHES)FEET
0 20
2
C500
PLANTING PIT DETAILS
NO SCALE
TYPICAL PLANTING PIT DETAIL SLOPE PLANTING PIT DETAIL
3X ROOTBALL
MINIMUM FOR TREES
2X ROOTBAL
MINIMUM FOR SHRUBSDEPTH OFROOT BALLOR CONTAINERROOT SYSTEM3X ROOTBALL
MINIMUM FOR TREES
2X ROOTBAL
MINIMUM FOR SHRUBSDEPTH OFROOT BALLOR CONTAINERROOT SYSTEMSET ROOT COLLAR AND
ROOT FLARE 2" ABOVE
FINISH GRADE. DO NOT
PLACE MULCH WITHIN 2"
OF TRUNK. ROOT
COLLAR IS NOT ALWAYS
LOCATED AT TOP OF
ROOTBALL
MINIMUM 6' DIAMETER,
3" DEPTH MULCH RING
3" HEIGHT WATER RETENTION
BERM BEYOND EDGE OF ROOT BALL
FINISH GRADE
SCARIFY SIDES OF PIT
REMOVE ALL NON-BIODEGRADABLE MATERIAL,
CONTAINERS OR OTHER MATERIAL THAT WILL
IMPEDE THE GROWTH OF THE PLANT MATERIAL.
REMOVE ALL TWINE. FOR BALLED AND BURLAP
(B&B) PLANTS REMOVE MINIMUM TOP 1
2 OF BURLAP
AND WIRE BASKET MINIMUM.
PLACE ROOT BALL ON UNDISTURBED SOIL
2:1 MAXIMUM TRANSITION SLOPE.
BEGIN TRANSITION AT EDGE OF
ROOT BALL
EXISTING
SLOPE
TREE OR SHRUB
SCARIFY SIDES OF PIT
REMOVE ALL NON-BIODEGRADABLE MATERIAL,
CONTAINERS OR OTHER MATERIAL THAT WILL
IMPEDE THE GROWTH OF THE PLANT MATERIAL.
REMOVE ALL TWINE. FOR BALLED AND BURLAP
(B&B) PLANTS REMOVE MINIMUM TOP 1
2 OF BURLAP
AND WIRE BASKET MINIMUM.
PLACE ROOT BALL ON UNDISTURBED SOIL
FINISH GRADE
3" HEIGHT WATER RETENTION
BERM BEYOND EDGE OF ROOT BALL
MINIMUM 6' DIAMETER,
3" DEPTH MULCH RING
SET ROOT COLLAR AND ROOT FLARE 2" ABOVE
FINISH GRADE. DO NOT PLACE MULCH WITHIN
2" OF TRUNK. ROOT COLLAR IS NOT ALWAYS
LOCATED AT TOP OF ROOT BALL
(AS PER CITY OF WAUKEE SITE PLAN ORDINANCE)
OPEN SPACE AREA REQUIREMENTS:
66,704 S.F. TOTAL LOT AREA x 15%= 10,006 S.F. REQUIRED
11,320 S.F. TOTAL OPEN SPACE PROVIDED (17.0%)
31,984 S.F. OF PAVEMENT AREA SHOWN
NO INTERIOR LANDSCAPE REQUIREMENTS LISTED
OPEN SPACE PLANTING REQUIREMENTS:
66,704 S.F. TOTAL LOT AREA x 15%= 10,006 S.F. REQUIRED
1 TREE/1,000 S.F. REQ'D OPEN SPACE
10 TREES REQUIRED (10 PROVIDED)
1 SHRUB/1,000 S.F. REQ'D OPEN SPACE
10 SHRUBS REQUIRED (12 PROVIDED)
PLANTING PLAN CONSTRUCTION NOTES
A.UTILITY WARNING:
THE UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND/OR RECORDS
OBTAINED. THE SURVEYOR MAKES NO GUARANTEE THAT THE UTILITIES SHOWN COMPRISE ALL SUCH
UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEY FURTHER DOES NOT WARRANT
THAT THE UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED.
B.NOTIFY UTILITY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR
DETERMINING EXISTENCE, EXACT LOCATION AND DEPTH OF ALL UTILITIES. AVOID DAMAGE TO UTILITIES
AND SERVICES DURING CONSTRUCTION. ANY DAMAGE DUE TO THE CONTRACTOR'S CARELESSNESS SHALL
BE CORRECTED AT THE CONTRACTOR'S EXPENSE. COORDINATE AND COOPERATE WITH UTILITY
COMPANIES DURING CONSTRUCTION.
C.ALL PLANT MATERIAL SHALL AT LEAST MEET MINIMUM REQUIREMENTS SHOWN IN THE "AMERICAN
STANDARDS FOR NURSERY STOCK" (ANSI Z60.1-LATEST EDITION).
D.CONTRACTOR SHALL GUARANTEE ALL PLANT MATERIAL FOR A PERIOD OF ONE YEAR FROM DATE OF
INSTALLATION.
E.PROVIDE A MIN 3-FOOT PERIMETER RING OF SHREDDED HARDWOOD MULCH AROUND ALL TREES. FOR
GROUPINGS OF SHRUBS WITHIN THE OPEN SPACE, THEY SHALL BE PLANTED IN THE DEFINED MULCH BEDS.
PROVIDE VERTICAL CUT NATURAL EDGE TO A DEPTH OF 4-INCHES FOR BOTH SITUATIONS.
F.SOD ALL AREAS DISTURBED BY CONSTRUCTION, INCLUDING WITHIN THE PUBLIC R.O.W., UNLESS DIRECTED
BY OWNER OR SHOWN OTHERWISE ON THE LANDSCAPE PLAN.
G.PROVIDE 1.5-2" DIAMETER RIVER ROCK AND WEED FABRIC AS SHOWN.
H.CONTRACTOR TO SEED AREA OF OFF SITE STORM SEWER CONSTRUCTION WITH SUDAS TYPE 1 PERMANENT
LAWN SEED MIX.
PLANTING PLAN REQUIREMENTS
PLANT SCHEDULE
QTY KEY BOTANICAL NAME COMMON NAME
MINIMUM
INSTALL SIZE
HEIGHT
COMMENTS
CANOPY TREES
2 GT Gleditsia triacanthos var. inermis 'Skycole'SKYLINE HONEYLOCUST 2" CAL. & 8' HT.B&B
4 QR Quercus x warei 'Long'REGAL PRINCE OAK 2" CAL & 8' HT..B&B
EVERGREEN TREES
4 PG Picea glauca densata BLACK HILLS SPRUCE 6' HT.B&B
DECIDUOUS SHRUBS
6 EA Euonymus alatus 'Compactus'COMPACT BURNING BUSH 24" HT.#3 CONT. (7' O.C.)
8 HY Hydrangea paniculata 'Renhy'VANILLA STRAWBERRY HYDRANGEA 36" HT.#3 CONT. (6' O.C.)
6 VL Viburnum lentago 'Mohican'MOHICAN VIBURNUM 24" HT.#3 CONT. (7' O.C.)
1
C500
DECIDUOUS TREES STAKING DETAIL
NO SCALE
STAKING PLAN
(TREES 2 1/2" DIA OR SMALLER)
STAKING PLAN
(TREES LARGER THAN 2 1/2" DIA)
1 WRAP TRUNK FROM GROUND TO FIRST BRANCH.12 TO 23 TREE HEIGHT(4'-0" MIN)1
4 TO 1
3
TREE HEIGHT
(2'-0" MIN)6"SEE PLANTING PIT
DETAILS
GARDEN
HOSE FLAGGING
MATERIAL
1
PLACE ON STAKE
TO SOUTHWEST
PLACE ON STAKE
TO SOUTHWEST
MINIMUM TREE HEIGHT:
DECIDUOUS OVERSTORY 8'
EVERGREEN OVERSTORY 6'
DECIDUOUS ORNAMENTAL 6'
FIELD VERIFY ALL SITE
DIMENSIONS AND BEARINGS
Buck Kerndt - Webster City Iowa
Waukee Iowa
Elevation
Pella Building Systems, INC.
906 WEST 9TH ST.
Pella, Iowa 50219
1-800-225-0491 or 1-641-628-9300
www.Pellabuilding.com
NICHIHA STONE
NICHIHA STONE
NICHIHA STONE
NICHIHA STONE
NICHIHA STONE
FW 120 PANELFW 120 PANEL
Percentage of Materials
South - 90' x 16'
Total Square Foot = 1,530
Nichiha = 1,080
FW120 = 441
North - 90' x 16'
Total Square Foot = 1,530
Nichiha = 630
FW120 = 900
East/West - 260' x 16'
Total Square Foot = 8,320
Nichiha = 1,540
FW120 = 3,000
Total For Building
Total Square Foot = 11,380
FW120
Total sqft 4,341 = 38.2%