HomeMy WebLinkAbout2023-09-18 I09A-C Stivers Ford Pro Center_Preliminary Plat, Final Plat, Site Plan AGENDA ITEM:
CITY OF WAUKEE, IOWA
CITY COUNCIL MEETING COMMUNICATION
MEETING DATE: September 18, 2023
AGENDA ITEM: Consideration of approval of resolutions approving a preliminary plat, final
plat, and site plan for Stivers Ford Pro Center / Williams Pointe Plat 16
FORMAT: Resolutions
SYNOPSIS INCLUDING PRO & CON: The applicant is requesting approval of a preliminary plat,
final plat, and site plan for an automotive service center, located west of SE
Waco Place and south of SE Stone Ridge Drive, containing 7.58-acres.
The project involves the construction of a two-story building to be used as an
automotive service center. The building is approximately 34,150 square feet in
area. The building will be used for commercial vehicle service and also sales
of vehicles and products.
The project also includes improvements to the existing parking lot. A trash
enclosure will be provided on the east side of the building. Several overhead
doors will be provided on the building, with the majority of them on the south
elevation.
The final plats includes two lots. Lot 1 is 2.53-acres in area and includes the
existing building. Lot 2 is 5.06-acres in area and will include the proposed
building.
Two driveways will be provided off of SE Stone Ridge Drive. Parking meets
the requirements of the ordinance. A minimum of 20% is required to be open
space and the applicant is providing 48% open space.
Elevations of the proposed buildings comply with the Site Plan Ordinance
requirements. Materials include metal panel, ACM wall panel, brick, and glass
storefront.
FISCAL IMPACT INCLUDING COST/BENEFIT ANALYSIS:
COMMISSION/BOARD/COMMITTEE COMMENT: The Planning and Zoning Commission
reviewed the preliminary plat, site plan and final plat request at their
meeting on July 11, 2023 and recommended approval:
Approval of Stivers Ford Pro Center – Preliminary Plat/Site Plan and Williams Pointe
Plat 16 – Final Plat
Planning Coordinator, Melissa DeBoer, introduced the request for a preliminary plat,
final plat, and site plan for an automotive service center for Stivers Ford Pro Center, as
submitted by Stivers Iowa Real Estate, LLC.
I9A-C
The property is generally located west of SE Waco Place and south of SE Stone Ridge
Drive, containing approximately 7.58 acres. The subject property is currently six lots and
contains an autobody shop for Stivers Ford and a display parking lot. The applicant is
proposing to plat the lots in order to combine them into two total lots. Lot 1 will contain the
existing autobody shop and Lot 2 will contain the proposed building.
The project involves construction of a two-story building to be used as an automotive
service center. The building is approximately 34,150 square feet in area. The building will be
used for commercial vehicle service and products. The site will also include vehicle sales.
The project also includes improvements to the existing parking lot. A trash enclosure is
shown on the east side of the building. Several overhead doors are proposed on the building
in order to service vehicles, with the majority of them on the south elevation of the building.
Two driveways off of SE Stone Ridge Drive are proposed to provide access to this
site. One is the existing access to the east and will be a shared access. A total of 80 parking
spaces are required. The site plan identified 124 standard parking spaces and 14 over-sized
truck parking spaces being provided, for a total of 138 parking spaces.
A five-foot-wide sidewalk will be constructed along both SE Stone Ridge Drive and
SE Brick Drive as part of the site improvements. The site will be serviced with all public
utilities that exist in the immediate vicinity. Stormwater management will be provided with
several bioretention ponds throughout the site as well as with the existing regional detention
pond at the south side of the site. Landscape and open space requirements have been met.
Elevations are proposed to be constructed mostly of metal panel, ACM wall panel,
brick, and glass storefront system. The trash enclosure will be composed of split face
concrete block and a composite wood gate.
The preliminary plat, final plat, and site plan are in general conformance with the
Zoning Ordinance, Subdivision Ordinance, Site Plan Ordinance and Comprehensive Plan.
Staff recommends approval of preliminary plat, final plat, and site plan subject to any
remaining staff comments and review of legal documents.
Commissioner Streit moved to approve a preliminary plat for an automotive service
center for Stivers Ford Pro Center, subject to any remaining staff comments and review of
legal documents. The motion was seconded by Commissioner Beenken. Ayes: Ayes:
Beenken, Streit, Tessau, Lohse, and Bankole. Nays: None. Motion carried.
Commissioner Streit moved to approve a final plat for Williams Pointe Plat 16, subject
to any remaining staff comments and review of legal documents. The motion was seconded
by Commissioner Beenken. Ayes: Ayes: Beenken, Streit, Tessau, Lohse, and Bankole.
Nays: None. Motion carried.
Commissioner Streit moved to approve a site plan for Stivers Ford Pro Center, 1300
SE Stone Ridge Drive, subject to any remaining staff comments and review of legal
documents. The motion was seconded by Commissioner Beenken. Ayes: Ayes: Beenken,
Streit, Tessau, Lohse, and Bankole. Nays: None. Motion carried.
STAFF REVIEW AND COMMENT: Staff recommends approval of the preliminary plat, final plat
and site plan for Stivers Ford Pro Center / Williams Pointe Plat 16 subject to
remaining staff comments.
RECOMMENDATION: Approve the resolutions.
ATTACHMENTS: I. Proposed Resolutions
II. Staff Report
III. Preliminary Plat / Site Plan
IV. Final Plat
V. Building Elevations
PREPARED BY: Melissa DeBoer, Planning Coordinator
REVIEWED BY:
PUBLIC NOTICE INFORMATION –
NAME OF PUBLICATION:
DATE OF PUBLICATION:
THE CITY OF WAUKEE, IOWA
RESOLUTION 2023-
APPROVING THE PRELIMINARY PLAT FOR STIVERS FORD PRO CENTER
IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA
WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal
Organization; AND,
WHEREAS, the City of Waukee Planning and Zoning Commission reviewed and recommended
approval of a Preliminary Plat for Stivers Ford Pro Center on July 11, 2023; AND,
WHEREAS, the Preliminary Plat for Stivers Ford Pro Center is in general conformance with
section §176 - Subdivision Regulations of the Waukee Municipal Code.
NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on
this the 18th day of September, 2023 that the Preliminary Plat for Stivers Ford Pro Center be
approved subject to remaining staff comments.
____________________________
Courtney Clarke, Mayor
Attest:
___________________________________
Rebecca D. Schuett, City Clerk
RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN
Anna Bergman Pierce
R. Charles Bottenberg
Chris Crone
Larry R. Lyon
Ben Sinclair
THE CITY OF WAUKEE, IOWA
RESOLUTION 2023-
APPROVING THE FINAL PLAT FOR WILLIAMS POINTE PLAT 16
IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA
WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal
Organization; AND,
WHEREAS, Stivers Iowa Real Estate LLC, has requested final plat approval of Williams Pointe Plat
16 (the “Plat”); AND,
WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of the Plat
on July 11, 2023, subject to remaining staff comments and review of the legal documents; AND,
WHEREAS, the Final Plat for Williams Pointe Plat 16 and the documents relating thereto will comply
with section §176 – Subdivision Regulations of the Waukee Municipal Code.
NOW, THEREFORE, BE IT RESOLVED by the City Council of the City of Waukee, Iowa on this
18th day of September, 2023, that the Final Plat for Williams Pointe Plat 16 be and the same is hereby
accepted and approved by the City Council of the City of Waukee.
BE IT FURTHER RESOLVED that the City of Waukee does hereby accept the following easements
and documents to be filed with the Plat:
1. Public Ingress Egress Easement; and
2. Private Water Main Easement
____________________________
Courtney Clarke, Mayor
Attest:
___________________________________
Rebecca D. Schuett, City Clerk
RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN
Anna Bergman Pierce
R. Charles Bottenberg
Chris Crone
Larry R. Lyon
Ben Sinclair
THE CITY OF WAUKEE, IOWA
RESOLUTION 2023-
APPROVING THE SITE PLAN FOR STIVERS FORD PRO CENTER (1300 SE STONE
RIDGE DRIVE)
IN THE NAME AND BY THE AUTHORITY OF THE CITY OF WAUKEE, IOWA
WHEREAS, the City of Waukee, Dallas County, State of Iowa, is a duly organized Municipal
Organization; AND,
WHEREAS, the City of Waukee Planning and Zoning Commission recommended approval of
the Site Plan for Stivers Ford Pro Center, subject to remaining staff comments on July 11, 2023;
AND,
WHEREAS, the Site Plan for Stivers Ford Pro Center is in general conformance with §160 –
Site and Building Development Standards Ordinance of the Waukee Municipal Code; AND,
WHEREAS, the Site Plan for Stivers Ford Pro Center is in general conformance with §161 –
Landscaping and Open Space Ordinance of the Waukee Municipal Code; AND,
NOW THEREFORE BE IT RESOLVED by the City Council of the City of Waukee, Iowa on
this 18th day of September, 2023 that the Site Plan for Stivers Ford Pro Center is approved
subject to remaining staff comments.
____________________________
Courtney Clarke, Mayor
Attest:
___________________________________
Rebecca D. Schuett, City Clerk
RESULTS OF VOTE: AYE NAY ABSENT ABSTAIN
Anna Bergman Pierce
R. Charles Bottenberg
Chris Crone
Larry R. Lyon
Ben Sinclair
PLANNING AND ZONING COMMISSION STAFF REPORT
PROJECT: Stivers Ford Pro Center – Preliminary
Plat / Site Plan and Williams Pointe Plat
16 – Final Plat
PREPARED BY: Melissa DeBoer, AICP – Planning
Coordinator
REPORT DATE: July 7, 2023
MEETING DATE: July 11, 2023
GENERAL INFORMATION
Applicant / Owner: Stivers Iowa Real Estate, LLC
Engineer: Seth Sunderman, P.E. with Bishop Engineering
Company, Inc.
Request: The applicant is requesting approval of a
preliminary plat, final plat, and site plan for an
automotive service center for Stivers Ford Pro
Center.
Location and Size: Property is generally located west of SE Waco
Place and south of SE Stone Ridge Drive, containing
approximately 7.58 acres.
Property Address: 1300 SE Stone Ridge Drive
AREA MAP
ABOVE: Aerial of subject property (outlined in BLUE) in relation to the surrounding area.
July 6, 2023
2 of 3
LAND USES AND ZONING
Location Existing Land Use Comprehensive Plan Current Zoning
Property in
Question
Undeveloped / Stivers Ford
Autobody Shop and parking
lot
Neighborhood Residential C-1 / PD-1 ( Community &
Highway Service
Commercial District /
Planned Development
Overlay)
North Retail Neighborhood Residential C-1 / PD-1 ( Community &
Highway Service
Commercial District /
Planned Development
Overlay)
South Alice Place Senior Living Neighborhood Residential R-3 / PD-1 (Multi-Family
Residential District /
Planned Development
Overlay)
East Stivers Ford Lincoln Auto
Dealership
Neighborhood Residential C-1 (Community & Highway
Service Commercial District)
West LockBox Storage – self
storage
Neighborhood Residential C-1 / PD-1 ( Community &
Highway Service
Commercial District /
Planned Development
Overlay)
HISTORY
The subject property is currently six lots and contains an autobody shop for Stivers Ford and a display parking
lot. The applicant is proposing to plat the lots in order to combine them into two total lots. Lot 1 will contain
the existing autobody shop and Lot 2 will contain the proposed building for the Stivers Ford Pro Center.
PROJECT DESCRIPTION
The project involves the construction of a two-story building to be used as an automotive service center. The
building is approximately 34,150 square feet in area. The building will be used for commercial vehicle service
and products. The site will also include vehicle sales.
The project also includes improvements to the existing parking lot. A trash enclosure is shown on the east
side of the building. Several overhead doors are proposed on the building in order to service vehicles, with the
majority of them on the south elevation of the building.
The final plat includes a total of two lots. Lot 1 is 2.53 acres in area and includes the existing building. Lot 2 is
5.06 acres in area and will include the proposed building.
ACCESS AND PARKING
Two driveways off of SE Stone Ridge Drive are proposed to provide access to this site. One is the existing
access to the building to the east and will be a shared access.
A total of 80 parking spaces are required. The site plan identifies 124 standard parking spaces and 14 over-
sized truck parking spaces being provided, for a total of 138 parking spaces.
July 6, 2023
3 of 3
SIDEWALKS/TRAILS
A 5 foot wide sidewalk will be constructed along both SE Stone Ridge Drive and SE Brick Drive as part of the
site improvements. A pedestrian connection will provide access into the site from the sidewalk along SE Stone
Ridge Drive.
EASEMENTS
All proposed easements have been indicated on the final plat. A shared ingress/egress easement will be
provided for the east driveway.
UTILITIES
All utilities are available at this site and services will be brought in to the site to serve the proposed building.
Storm water management will be provided with several bioretention ponds throughout the site as well as with
the existing regional detention pond at the south side of the site.
LANDSCAPING & OPEN SPACE
A minimum of 20% of the project area is required to be open space. The total amount of open space
proposed is approximately 48%.
Plantings are being provided throughout the site in compliance with the Landscape & Open Space Ordinance.
ELEVATIONS
The elevations are proposed to be constructed mostly of metal panel, ACM wall panel, brick, and glass
storefront system. The trash enclosure will be composed of split face concrete block and a composite wood
gate.
STAFF RECOMMENDATION
The preliminary plat, final plat, and site plan are in general conformance with the Zoning Ordinance,
Subdivision Ordinance, Site Plan Ordinance, and Comprehensive Plan. Staff recommends approval of the
preliminary plat, final plat, and site plan subject to any remaining staff comments and review of the legal
documents.
6
SITE
STIVERS FORD PRO CENTER
SITE PLAN/PRELIMINARY PLAT
IOWAONE CALL
1-800-292-8989
www.iowaonecall.com
811
Know what's below.
Call before you dig.
VICINITY MAP
NOT TO SCALE
COPYRIGHT 2023 BISHOP ENGINEERING. THIS DOCUMENT AND THE INFORMATION CONTAINED MAY NOT BE
REPRODUCED OR EXCERPTED WITHOUT THE EXPRESS WRITTEN PERMISSION OF BISHOP ENGINEERING.
UNAUTHORIZED COPYING OR DISCLOSURE OF CONSTRUCTION USE ARE PROHIBITED BY COPYRIGHT LAW.
LEGEND:
SAN SANITARY SEWER
ST STORM SEWER
W WATER LINE
G GAS LINE
U/E UNDERGROUND ELECTRIC
O/E OVERHEAD ELECTRIC
TELE TELEPHONE LINE
F/O FIBER OPTIC
CATV CABLE TV
STORM MANHOLE
CURB INTAKE
SURFACE INTAKE
FLARED END SECTION
SANITARY MANHOLE
CLEANOUT
FIRE HYDRANT
SPRINKLER
IRRIGATION CONTROL VALVE
WATER MANHOLE
WELL
WATER VALVE
WATER SHUT OFF
YARD HYDRANT
ELECTRIC MANHOLE
ELECTRIC METER
ELECTRIC RISER
ELECTRIC VAULT
POWER POLE
TRANSFORMER POLE
LIGHT POLE
ELECTRIC JUNCTION BOX
ELECTRIC PANEL
TRANSFORMER
GROUND LIGHT
GUY WIRE
ELECTRIC HANDHOLE
GAS METER
GAS VALVE
AIR CONDITIONING UNIT
TELEPHONE RISER
TELEPHONE VAULT
TELEPHONE MANHOLE
TRAFFIC SIGNAL MANHOLE
FIBER OPTIC RISER
FIBER OPTIC FAULT
CABLE TV RISER
SIGN
7 DENOTES NUMBER OF PARKING STALLS
PROPERTY CORNER - FOUND AS NOTED
PROPERTY CORNER- PLACED 3/4" IRON PIPE
WITH YELLOW PLASTIC CAP ID #14775
SECTION CORNER - FOUND AS NOTED
D
S
CO
H Y D
I CV
W
WS O
Y
A DR
E
EM
E
ELEC
EJ
EP
GM
GV
A/C
T
TEL
T
TS
FO
F/O
TV
W
WV
SHEET INDEX:
C0.1 COVER SHEET
C1.1 EX. CONTIONS & DEMO PLAN
C2.1 LAYOUT PLAN
C3.1 GRADING PLAN
C4.1 UTILITY PLAN
C5.1 LANDSCAPE PLAN
C6.1 DETAILS SHEET
C6.2 DETAILS SHEET
C6.3 DETAILS SHEET
C7.1 SWPPP
UTILITY CONFLICT NOTES:
1.UTILITY CONFLICTS MAY EXIST ACROSS THE SITE WITH NEW UTILITIES, GRADING, PAVING ETC.
MOST UTILITY CONFLICTS HAVE BEEN CALLED OUT FOR CONTRACTOR CONVENIENCE.
2.CONTRACTOR IS RESPONSIBLE FOR ALL UTILITY CONFLICTS THAT ARE EITHER CALLED OUT ON
THE PLANS OR THAT CAN BE SEEN ON THE PLANS BETWEEN AN EXISTING UTILITY AND
PROPOSED CONSTRUCTION
WETLAND NOTES:
1.BISHOP ENGINEERING DOES NOT PERFORM WETLAND STUDIES OR WETLAND MITIGATION. IT IS
THE OWNER'S RESPONSIBILITY TO DETERMINE IF ANY WETLANDS ARE LOCATED ON THE
PROJECT SITE AND PERFORM ANY NECESSARY MITIGATION PRIOR TO THE COMMENCEMENT OF
CONSTRUCTION ACTIVITIES.
SURVEY NOTES:
1.SURVEY WORK WAS COMPLETED BY BISHOP ENGINEERING ON 10-18-2022.
GENERAL NOTES:
1.ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2023 CITY OF WAUKEE STANDARD SPECIFICATIONS AND 2023 SUDAS STANDARD SPECIFICATIONS AND ANY AND
ALL CITY/COUNTY SUPPLEMENTAL SPECIFICATIONS. THE CITY OF WAUKEE MUST BE NOTIFIED BY ALL CONTRACTORS 48 HOURS PRIOR TO COMMENCING WORK.
2.IN EVENT OF A DISCREPANCY BETWEEN THE QUANTITY ESTIMATES AND THE DETAILED PLANS, THE DETAILED PLANS SHALL GOVERN.
3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION OF ALL UTILITIES. ANY DAMAGE TO SAID UTILITIES SHALL BE REPAIRED AT THE CONTRACTORS EXPENSE.
4.ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE CURRENT O.S.H.A. CODES AND STANDARDS. NOTHING INDICATED ON THESE PLANS SHALL RELIEVE THE
CONTRACTOR FROM COMPLYING WITH THE APPROPRIATE SAFETY REGULATIONS.
5.ALL NECESSARY CONSTRUCTION SIGNS, BARRICADES AND OTHER TRAFFIC CONTROL DEVICES REQUIRED DURING CONSTRUCTION WILL BE FURNISHED BY THE
CONTRACTOR. SIGNS, BARRICADES AND OTHER TRAFFIC CONTROL DEVICES MUST BE IN CONFORMANCE WITH THE "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES
FOR STREETS AND HIGHWAYS."
6.BISHOP ENGINEERING SHALL NOT BE LIABLE FOR ANY INJURIES THAT HAPPEN ON SITE. THIS SHALL INCLUDE BUT NOT BE LIMITED TO TRENCH COLLAPSES FROM
VARYING SOIL CONDITIONS OR INJURIES CAUSED BY UNDERGROUND UTILITIES INCLUDING UTILITIES THAT ARE NOT SHOWN ON PLAN.
7.THE CONTRACTOR IS LIABLE FOR ALL DAMAGES TO PUBLIC OR PRIVATE PROPERTY CAUSED BY THEIR ACTION OR INACTION IN PROVIDING FOR STORM WATER FLOW
DURING CONSTRUCTION. DO NOT RESTRICT FLOWS IN EXISTING DRAINAGE CHANNELS, STORM SEWER, OR FACILITIES.
8.THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER A SCHEDULE FOR PERFORMANCE OF WORK ITEMS. THIS SCHEDULE SHALL BE PROVIDED BY THE CONTRACTOR AT
THE PROJECT PRECONSTRUCTION CONFERENCE. NO WORK SHALL BEGIN UNTIL A SCHEDULE HAS BEEN SUBMITTED AND ACCEPTED. THE CONTRACTOR SHALL THEN
PERFORM WORK TO CONFORM TO THE ACCEPTED SCHEDULE.
9.LABORATORY TESTS SHALL BE PERFORMED BY THE OWNER UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL PROVIDE SAMPLES OF MATERIAL REQUIRED FOR
LABORATORY TESTS AND TESTING IN ACCORDANCE WITH THE URBAN STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS.
10.SOIL IMPORT OR EXPORT ON THIS PROJECT SHALL BE CONSIDERED INCIDENTAL AND WILL NOT BE MEASURED OR PAID FOR SEPARATELY.
11.THE CONTRACTOR SHALL PROTECT ALL STRUCTURES NOT SHOWN AS REMOVALS ON THE PLANS.
12.THE CONTRACTOR SHALL OBTAIN ANY AND ALL NECESSARY PERMITS PRIOR TO ANY CONSTRUCTION. CONTRACTOR SHALL WORK WITH OWNER OR OWNERS
REPRESENTATIVE ON ALL REQUIRED STORM WATER DISCHARGE PERMITS FROM THE IOWA DEPARTMENT OF NATURAL RESOURCES AND THE CITY OF WAUKEE.
13.GRADING AND EROSION CONTROL SHALL BE DONE IN ACCORDANCE WITH THE APPROVED GRADING PLAN, SWPPP, NPDES DOCUMENTS, AND IOWA DEPARTMENT OF
NATURAL RESOURCES REQUIREMENTS.
14.THE CONTRACTOR SHALL PICK UP ANY DEBRIS SPILLED ONTO THE ADJACENT RIGHT OF WAY OR ABUTTING PROPERTIES AS THE RESULT OF CONSTRUCTION, AT THE
END OF EACH WORK DAY AND PRIOR TO A RAIN EVENT.
15.THE CONTRACTOR IS RESPONSIBLE FOR THE PROMPT REMOVAL OF ALL MUD THAT HAS BEEN TRACKED OR WASHED UNTO ADJACENT PROPERTY OR RIGHT OF WAY
UNTIL SUCH TIME THAT PERMANENT VEGETATION HAS BEEN ESTABLISHED.
16.DISPOSE OF ALL EXCESS MATERIALS AND TRASH IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL REQUIREMENTS. PROVIDE WASTE AREAS OR DISPOSAL SITES
FOR EXCESS MATERIALS NOT DESIRABLE FOR INCORPORATION INTO THE PROJECT.
17.ALL SIGNAGE SHALL REQUIRE A SEPARATE PERMIT FROM THE CITY OF WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT.
18.ANY PROPOSED CHANGES TO THIS PLAN SET SHALL BE APPROVED IN WRITING BY THE CITY OF WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT.
19.CONTRACTOR SHALL BE RESPONSIBLE FOR ANY CHANGES MADE DURING CONSTRUCTION THAT HAVE NOT BEEN GRANTED APPROVAL IN WRITING BY THE CITY OF
WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT.
20.APPROVED FIRE APPARATUS ACCESS ROADS SHALL BE PROVIDED AS SOON AS CONSTRUCTION OF THE BUILDING COMMENCES.THE FIRE APPARATUS ACCESS ROAD
SHALL COMPLY WITH THE REQUIREMENTS OF THE IFC SECTION 503.2 AND SHALL EXTEND TO WITHIN 100 FEET OF ALL PORTIONS OF THE FACILITY AND ALL PORTIONS OF
THE EXTERIOR WALLS OF THE FIRST STORY OF THE BUILDING AS MEASURED BY AN APPROVED ROUTE AROUND THE EXTERIOR OF THE BUILDING OR FACILITY.
PAVING NOTES:
1.THE PAVING/ GRADING CONTRACTOR SHALL BACKFILL THE PAVING SLAB AND FINE GRADE THE RIGHT OF WAY AS SOON AFTER THE PAVING AS POSSIBLE. ALL AREAS
SHALL BE SODDED AND WATERED UNTIL ESTABLISHED IN ACCORDANCE WITH CITY OF WAUKEE STANDARD SPECIFICATIONS AND THE CURRENT VERSION OF SUDAS.
2.SUBGRADE PREPARATION AND PAVEMENTS WILL BE CONSTRUCTED FOLLOWING RECOMMENDATIONS IN THE SOILS REPORT. APPROVED SOILS ENGINEER MUST SIGN
OFF ON SUBASE PRIOR TO ANY PAVEMENT BEING PLACED.
3.SEE DETAILS FOR ALL PAVEMENT THICKNESS.
4.ALL PEDESTRIAN WALKWAYS THAT UNLOAD INTO A VEHICLES TRAVELED PATH MUST HAVE A.D.A. DETECTABLE WARNING PLANEL(S) AS PER A.D.A. REGULATIONS. PANEL
TYPE & COLOR SHALL BE PER CITY STANDARD.
5.ALL WALKS, PARKING LOTS, HANDICAP PARKING, RAMPS, ETC. SHALL COMPLY WITH ALL A.D.A. AND CITY CODES. HANDICAP PARKING SIGNAGE IS REQUIRED FOR ALL
HANDICAP STALLS AND SHALL BE CONSIDERED INCIDENTAL. IN EVENT OF A DISCREPANCY BETWEEN THE PLANS AND THE A.D.A./CITY CODES THE A.D.A./CITY CODES
SHALL GOVERN. CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING A.D.A. CODES ARE MET.
6.ALL DISTURBED AREAS THAT ARE NOT PAVED SHOULD BE SODDED
UTILITY NOTES:
1.QUANTITY CALLOUTS ON PIPE LENGTHS ARE APPROXIMATE AND SHOULD BE USED FOR REFERENCE ONLY.
2.THE CONTRACTOR SHALL PROVIDE AS-BUILTS OF ALL UTILITIES, INCLUDING DEPTH AND LOCATION OF ALL SERVICES.
3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION AND ALL COSTS ASSOCIATED WITH AS-BUILT TOPO OF DETENTION POND & DETENTION POND STORM
SEWER. CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING BISHOP ENGINEERING (DAVID BENTZ AT 515-276-0467) TO PERFORM SAID AS-BUILT SURVEY. IF
DETENTION PONDS HAVE BEEN GRADED INCORRECTLY, CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SUBSEQUENT AS-BUILT TOPO SURVEYS UNTIL ISSUES HAVE
BEEN RECTIFIED.
4.THE CONTRACTOR SHALL COORDINATE THE ADJUSTMENT OF ANY AND ALL EXISTING AND PROPOSED UTILITIES TO PROPOSED GRADES. EXISTING UTILITIES SHALL BE
RAISED OR LOWERED IN ACCORDANCE WITH THE UTILITY OWNER REQUIREMENTS. ANY NECESSARY ADJUSTMENTS SHALL BE CONSIDERED INCIDENTAL TO
CONSTRUCTION.
5.ACTIVE EXISTING FIELD TILES ENCOUNTERED DURING CONSTRUCTION SHALL BE REPAIRED, REROUTED, OR CONNECTED TO PUBLIC OR PRIVATE STORM SEWER TO
REMAIN IN SERVICE.
6.ALL PROPOSED RCP STORM SEWER PIPE JOINTS SHALL BE FABRIC WRAPPED AND THE LAST 3 PIPE SECTIONS ON THE APRON SHALL BE TIED WITH RF-14 TYPE II
CONNECTORS. ALL APRONS SHALL HAVE A STANDARD FOOTING AND TRASH GUARD.
7.ALL RIP RAP CALLED OUT ON PLANS SHALL BE UNDERLAIN WITH ENGINEERING FABRIC.
8.SANITARY SEWER SERVICE CONNECTIONS SHALL BE PLACED AT A SLOPE OF NO LESS THAN 2%. SERVICES SHALL MAINTAIN 18" OF VERTICAL SEPARATION FROM THE
WATERMAIN WITH 18" OF COMPACTED LOW PERMEABILITY SOIL BETWEEN THE UTILITIES WITHIN 10' OF THE CROSSING.
9.MANDREL AND PRESSURE TESTS SHALL BE REQUIRED FOR ALL PROPOSED SANITARY LINES. TELEVISING OF THE SANITARY SEWER SYSTEM SHALL BE COMPLETED
PRIOR TO PAVING UNLESS OTHERWISE APPROVED BY JURISDICTION.
10.WATERMAINS SHALL BE C-900. SIZE OF WATERMAIN AS SHOWN ON PLANS.
11.THRUST BLOCKS SHALL BE INSTALLED AS REQUIRED AND SHALL BE CONSIDERED INCIDENTAL TO WATERMAIN CONSTRUCTION.
12.PROPOSED WATERMAIN SHALL BE PRESSURE TESTED, BACTERIA TESTED AND CHLORINATED. THE FILLING OF THE WATER MAIN SHALL BE DONE BY THE CITY OF
WAUKEE.
13.TRACER WIRE SHALL BE ADDED TO ALL WATER MAIN, AND BROUGHT TO THE SURFACE AT EVERY HYDRANT.
14.ALL HYDRANTS WILL IMMEDIATELY BE COVERED WITH A BLACK PLASTIC BAG (OR EQUIVALENT) ONCE THE HYDRANT IS INSTALLED. THE CITY OF WAUKEE WILL NOTIFY
THE CONTRACTOR WHEN THE BAGS CAN BE REMOVED.
15.THE MINIMUM HYDRANT LEAD SHALL BE 3.5 FEET.
16.ALL HYDRANTS TO HAVE 5" STORZ FITTINGS.
17.CONTRACTOR TO COORDINATE TIE-INS TO EXISTING UTILITIES WITH THE CITY OF WAUKEE PUBLIC WORKS DEPARTMENT.
18.ALL UTILITIES TO BE TESTED TO CITY STANDARDS. CITY TO WITNESS ALL TESTING.
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
#
IS
S
U
E
D
A
T
E
NB
I
#
:
-
-
-
-
-
-
-
-
DB
S
#
:
2
2
-
3
-
4
4
2
DR
A
W
N
B
Y
:
G
S
A
CH
E
C
K
E
D
B
Y
:
S
V
S
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
#
IS
S
U
E
D
A
T
E
ST
I
V
E
R
S
GE
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
-
A
R
C
H
I
T
E
C
T
14
3
5
o
h
i
o
s
t
r
e
e
t
/
p
.
o
.
b
o
x
1
3
1
5
/
d
e
s
m
o
i
n
e
s
,
i
a
5
0
3
0
5
-
1
3
1
5
ph
o
n
e
:
(
5
1
5
)
2
4
3
-
0
1
5
6
/
f
a
x
:
(
5
1
5
)
2
4
3
-
0
1
6
5
NE
U
M
A
N
N
B
R
O
T
H
E
R
S
,
I
N
C
.
-
D
E
S
I
G
N
B
U
I
L
D
S
O
L
U
T
I
O
N
S
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Copyright DesignBuild Solutions, LC. Protected under Architectural Works Copyright Protection Act of 1990.
FIELD BULLETINS
ASSOCIATED WITH
THIS SHEET:
01
/
1
1
/
2
0
2
3
1S
T
C
I
T
Y
S
U
B
M
I
T
T
A
L
04
/
0
6
/
2
0
2
3
2N
D
C
I
T
Y
S
U
B
M
I
T
T
A
L
06
/
1
6
/
2
0
2
3
3R
D
C
I
T
Y
S
U
B
M
I
T
T
A
L
08
/
2
8
/
2
0
2
3
4T
H
C
I
T
Y
S
U
B
M
I
T
T
A
L
09
/
1
3
/
2
0
2
3
5T
H
C
I
T
Y
S
U
B
M
I
T
T
A
L
12
/
1
9
/
2
0
2
2
5
:
0
0
:
1
3
P
M
FO
R
D
P
R
O
C
E
N
T
E
R
13
5
0
S
E
S
t
o
n
e
R
i
d
g
e
D
r
i
v
e
,
W
a
u
k
e
e
,
I
o
w
a
5
0
2
6
3
L:
\
L
A
N
D
P
R
O
J
E
C
T
S
2
0
2
2
\
2
2
0
3
2
8
\
D
W
G
\
C
0
C
O
V
E
R
.
D
W
G
9/
1
3
/
2
0
2
3
1
:
5
5
:
5
5
P
M
UTILITY NOTE:
THE LOCATION OF THE UTILITIES INDICATED ON THE PLANS HAVE BEEN TAKEN FROM THE FIELD SURVEY, EXISTING PUBLIC
RECORDS, AND PLANS PROVIDED BY OTHERS. SURFACE UTILITY LOCATIONS HAVE BEEN FIELD LOCATED BY BISHOP
ENGINEERING, UNLESS OTHERWISE NOTED. ALL UNDERGROUND UTILITY LOCATIONS ARE APPROXIMATE LOCATIONS
ONLY. BISHOP ENGINEERING DOES NOT GUARANTEE THE UNDERGROUND LOCATION OF ANY UTILITIES SHOWN. IT SHALL
BE THE DUTY OF THE CONTRACTOR TO DETERMINE THE LOCATION AND DEPTH OF ANY UNDERGROUND UTILITIES SHOWN
AND IF ANY ADDITIONAL UTILITIES, OTHER THAN THOSE SHOWN ON THE PLANS, MAY BE PRESENT. A REQUEST WAS MADE
TO IOWA ONE CALL FOR UTILITY PROVIDERS TO VERIFY, LOCATE, AND MARK THEIR UTILITIES IN THE FIELD.
ABBREVIATIONS:
AC ACRES
ASPH ASPHALT
BK BOOK
CONC CONCRETE
D DEEDED DISTANCE
EX EXISTING
ENCL ENCLOSURE
FF FINISHED FLOOR
FL FLOW LINE
FRAC FRACTIONAL
M MEASURED DISTANCE
MH MANHOLE
OPC ORANGE PLASTIC CAP
P PLATTED DISTANCE
PG PAGE
POB POINT OF BEGINNING
POC POINT OF COMMENCEMENT
PRA PREVIOUSLY RECORDED AS
PUE PUBLIC UTILITY EASEMENT
ROW RIGHT OF WAY
RPC RED PLASTIC CAP
SF SQUARE FEET
SAN SANITARY
TYP TYPICAL
YPC YELLOW PLASTIC CAP
N NORTH
S SOUTH
E EAST
W WEST
C0.1, C1.1, C2.1, C3.1, C4.1, C6.1, C6.2, C6.3 & C7.1
PROPERTY DESCRIPTION:
QUIT CLAIM DEED BOOK: 2015 PAGE: 20587
LOTS 2, 3, 4, 5, 6 AND 7, IN WILLIAMS POINTE PLAT 14, AN OFFICIAL PLAT, NOW
INCLUDED IN AND FORMING A PART OF THE CITY OF WAUKEE, DALLAS COUNTY,
IOWA.
SAID TRACT OF LAND SUBJECT TO ALL EASEMENTS AND ENCUMBRANCES OF
RECORD.
SUBJECT TO AND TOGETHER WITH ANY AND ALL EASEMENTS AND RESTRICTIONS
OF RECORD.
SAID TRACT OF LAND CONTAINS 7.58 ACRES (330,521 SF) MORE OR LESS.
TOTAL AREA:
330,521 SQUARE FEET - 7.58 ACRES
ADDRESS:
1350 SE STONE RIDGE DR
WAUKEE, IOWA 50263
OWNER:
STIVERS IOWA REAL ESTATE LLC
1450 EAST HICKMAN ROAD
WAUKEE, IOWA 50263
CONTACT: SCOTT POLITTE
PH: 515-987-3697
PREPARED FOR:
STIVERS IOWA REAL ESTATE LLC
1450 EAST HICKMAN ROAD
WAUKEE, IOWA 50263
PROJECT MANAGER:
MATTHEW KELLER
NEUMANN BROTHERS
1435 OHIO STREET
DES MOINES, IOWA 50314
ENGINEER:
BISHOP ENGINEERING
CONTACT: SETH SUNDERMANN
3501 104TH STREET
URBANDALE, IOWA 50322
PH: (515) 276-0467
ZONING:
INFORMATION OBTAINED FROM
THE CITY OF WAUKEE ZONING MAP
ZONED: C-1 (COMMUNITY AND HIGHWAY SERVICE COMMERCIAL DISTRICT)
AND PD (PLANNED DEVELOPMENT DISTRICT - BOOK 2013 PAGE 10218 / ORD 2726).
FOR AN OFFICIAL ZONING REPORT PLEASE CALL CITY OF WAUKEE AT
(515) 978-9533
SETBACKS
FRONT YARD 30 FEET (MIN.)
REAR YARD 30 FEET (MIN.)
SIDE YARD NONE
MAX HEIGHT NONE
OCCUPANCY GROUP & DIVISION:
RENTAL / RETAIL
PARKING REQUIREMENTS:
AUTOMOTIVE SERVICE
REQUIRED:
3 SPACES / 1 SERVICE BAY X 12 BAYS = 36 STALLS
1 SPACE / 1 SERVICE VEHICLE X 2 SERVICE VEHICLES = 2 STALLS
2.5 SPACES / 1000 SF NON SERVICE AREA X 4080 SF = 11 STALLS
PARKING REQUIRED = 49 STALLS
EX. BUILDING PARKING REQUIRED = 31 STALLS (PER PREVIOUS SITE PLAN)
TOTAL PARKING REQUIRED = 80 STALLS
TYPICAL PARKING STALLS PROVIDED = 124 STALLS
OVER-SIZED TRUCK PARKING STALLS PROVIDED = 14 STALLS
OPEN SPACE/IMPERVIOUS REQUIREMENTS:
SITE AREA = 220,399 S.F. (5.06 AC)
REQUIRED OPEN SPACE = 44,080 S.F. (20%)
EXISTING OPEN SPACE = 181,743 S.F. (82.5%)
EXISTING IMPERVIOUS = 38,656 S.F (17.5%)
PROPOSED OPEN SPACE = 99,947 S.F. (45.3%)
PROPOSED IMPERVIOUS = 120,452 S.F (54.7%)
NET INCREASE IMPERVIOUS AREA = 81,796 S.F. (1.88 ACRES)
100-YEAR FLOOD ELEVATION:
NOT IN 100-YEAR FLOOD PLAIN
SITE CONTROL AND BENCHMARKS:
BASIS OF BEARING OBTAINED FROM GPS OBSERVATIONS DATUM = NAD 83, IOWA
SOUTH
BENCHMARK DATUM = NAVD88, GEOID 18
POINT #100, 3/4" IRON PIPE W/ YELLOW PLASTIC CAP
NORTHING = 587,608.16
EASTING = 1,545,183.16
ELEVATION = 1032.78
DESCRIPTION: WEST OF S.W. CORNER, LOT 7
POINT #9011, 3/4" IRON PIPE W/ RED PLASTIC CAP
NORTHING = 588,181.34
EASTING = 1,545,646.71
ELEVATION = 1019.82
DESCRIPTION: NORTH OF N.E. CORNER, LOT 3
PAVEMENT SAWCUT NOTES:
1.CONTRACTOR TO PROVIDE SAWCUT JOINTING PLAN TO SETH SUNDERMAN, BISHOP ENGINEERING (515-276-0467
OR SSUNDERMAN@BISHOPENGR.COM) PRIOR TO ANY CONCRETE PAVEMENT INSTALLATION.
2.PAVEMENT MAY BE REQUIRED TO BE REMOVED AND REPLACED IF PLACED WITHOUT AN APPROVED PLAN.
3.LONGITUDINAL JOINTS IN DRIVE LANES & THE OUTER MOST JOINT OF ALL PARKING AREAS SHALL BE SUDAS TYPE
'L-1' OR 'L-2' JOINTS AND HAVE STEEL. INTERIOR PARKING LOT JOINTS, OTHER THAN THE OUTER MOST JOINT, DO
NOT NEED STEEL AND SHALL BE SUDAS TYPE 'B' JOINTS.
4.TYPICAL LONGITUDINAL JOINTS SHALL BE PLACED IN THE CENTER OF ALL DRIVE AISLES AND AT THE END OF ALL
PARKING STALLS.
5.ALL TRANSVERSE JOINTS SHALL BE SUDAS TYPE 'C' OR TYPE 'DW' JOINTS WITH STEEL IN THE CASE OF A DAY'S
WORK JOINT.
PAVEMENT PLACEMENT NOTES:
1.SEE PROJECT SPECIFICATION SECTION 32 13 13 FOR LASER SCREED REQUIREMENTS.
STORM & SANITARY TELEVISING NOTES:
1.CONTRACTOR IS REQUIRED TO TELEVISE ALL SANITARY AND STORM SEWER SYSTEM PRIOR TO PAVING OPERATIONS.
2.CONTRACTOR SHALL SEND VIDEO INSPECTION TO THE ENGINEER FOR APPROVAL PRIOR TO PAVING.
3.CONTRACTOR SHALL PROVIDE COPIES OF THE REPORTS AND VIDEOS TO THE CITY OF WAUKEE ENGINEERING
DEPARTMENT FOR APPROVAL PRIOR TO PAVING.
REQUIRED AS-BUILTS:
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COST OF AS-BUILT TOPO OF ALL DETENTION PONDS & DETENTION
POND STORM SEWER, PUBLIC STORM SEWER, , RAMPS, LANDINGS, CROSSWALKS AND PUBLIC IMPROVEMENTS.
CONTRACTOR SHALL CONTACT BISHOP ENGINEERING (SETH SUNDERMAN AT 515-276-0467) TO PERFORM SAID
AS-BUILT SURVEYS. IF ANYTHING HAS BEEN CONSTRUCTED INCORRECTLY, CONTRACTOR SHALL BE RESPONSIBLE
FOR ALL SUBSEQUENT AS-BUILT SURVEYS UNTIL ISSUES HAVE BEEN RECTIFIED.
**CONTRACTOR SHALL CONTACT BISHOP ENGINEERING FOR POND AS-BUILTS AFTER TOPSOIL RESPREAD AND
BEFORE SEEDING HAS TAKEN PLACE**
AFTER DETENTION BASINS HAVE BEEN AS-BUILT AND APPROVED, BISHOP ENGINEERING SHALL PROVIDE A SIGNED
CERTIFICATION STATEMENT TO THE CITY OF WAUKEE INDICATING THAT FACILITIES WERE CONSTRUCTED AS
DESIGNED.
SPECIFICATIONS NOTES:
1.ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE STIVERS FORD PRO CENTER PROJECT SPECIFICATIONS,
CITY OF WAUKEE SPECIFICATIONS AND SUDAS SPECIFICATIONS.
2.FOR ANY DISCREPANCIES BETWEEN THE STIVERS FORD LINCOLN PROJECT SPECIFICATIONS AND THE CITY OF
WAUKEE REQUIREMENTS AND SPECIFICATIONS, PLUMBING CODE, AND URBAN STANDARD SPECIFICATIONS FOR
PUBLIC IMPROVEMENT (2023 EDITION SUDAS), THE 2023 CITY OF WAUKEE STANDARD SPECIFICATIONS SHALL
GOVERN.
3.FOR ALL SPECIFICATION DISCREPANCIES, PROJECT ENGINEER SHALL BE CONTACTED PRIOR TO PROCEEDING
WITH CONSTRUCTION. IF ENGINEER IS NOT CONTACTED, CONTRACTOR SHALL BE RESPONSIBLE FOR ANY
PROBLEMS THAT RESULT FROM SAID DISCREPANCIES.
4.FOR ALL SPECIFICATION DISCREPANCIES, CONTRACTOR MUST OBTAIN WRITTEN APPROVAL FROM THE CITY OF
WAUKEE ENGINEERING DEPARTMENT FOR ANY CHANGES TO PROPOSED SITE INFRASTRUCTURE OR GRADES
PRIOR TO PROCEEDING WITH ANY CHANGES.
SECURITY NOTES:
1.CONTRACTOR RESPONSIBLE FOR SECURITY OF THE SITE.
2.TEMPORARY FENCES OR ANY OTHER SECURITY MEASURES ARE THE RESPONSIBILITY OF THE CONTRACTOR.
3.NO SECURITY MEASURES WILL BE ELIGIBLE FOR A CHANGE ORDER AND MUST BE INCLUDED IN THE BASE BID.
STAKING NOTES:
1.CONTRACTOR IS REQUIRED TO HAVE ALL STAKING DONE UNDER THE SUPERVISION OF A LICENSED LAND SURVEYOR
AND IN COORDINATION WITH THE PROJECT ENGINEER.
2.CONTRACTOR IS REQUIRED TO HAVE ALL STAKING DONE DIRECTLY UNDER THE GENERAL CONTRACTOR BY A SINGLE
COMPANY.
3.STAKING DOES NOT RELIEVE CONTRACTOR OF ULTIMATE RESPONSIBILITY TO CONSTRUCT THE PROJECT PER PLAN.
EARTHWORK BALANCE NOTES:
1.SOIL IMPORT OR EXPORT ON THIS PROJECT SHALL BE CONSIDERED INCIDENTAL AND WILL NOT BE MEASURED OR PAID
FOR SEPARATELY. CONTRACTOR RESPONSIBLE FOR MAKING THE SITE EARTHWORK BALANCE.
2.THIS INCLUDES BUT IS NOT LIMITED TO TOPSOIL, POOR SOILS AND STRUCTURAL FILL NECESSARY TO MEET PROJECT
PLANS AND SPECIFICATIONS.
UTILITY MAPS PROVIDED BY:
1. ELECTRIC (MIDAMERICAN / (515) 252-6972)
2. STORM AND SANITARY (CITY OF WAUKEE / (515) 978-7920)
3. WATER & GAS (CITY OF WAUKEE / (515) 978-7920)
4. FIBER OPTIC (AUREON / (515) 830-0445)
5. FIBER OPTIC (CENTURYLINK / (918) 547-0147)
6. FIBER OPTIC (UNITE PRIVATE NETWORKS / (816) 425-3556)
7. TELEPHONE (MEDIACOM / (515) 246-6668)C0.1
COVER SHEET
CP #9011
EX 15 " FES
FL=1015.76
2" TREE
2" TREE
2" TREE
2" TREE
2" TREE
2" TREE
2" PINE
2" PINE
2" TREE
WV
H Y D
F/OF/O
EX 15 " FES
FL=1018.90
F/OFO
D
EX STORM MH
RIM=1025.75
FL(W)=1020.90
FL(NE)=1020.70
D
EX STORM MH
RIM=1024.69
FL(SW)=1020.34
FL(E)=1020.14
WV
H Y D
F/O
WV
WV
WV
H Y D
FO
3" TREE
S
EX SAN MH
RIM=1026.28
INV(N 8")=1013.30
INV(SE 8")=1013.23
4" TREE
D
EX 48" RECTANGULAR STORM MH
RIM=1017.70
FL(SW 15")=1013.00 (DEMO)
FL(W 18")=1012.80
FL(S 36")=1011.80
FL(E 42")=1011.70
S
EX SAN MH
RIM=1021.45
INV(E 8")=1004.33
INV(W 8")=1004.30
S
EX SAN MH
RIM=1022.79
INV(W 8")=1005.04
INV(E 8")=1004.99
INV(S 8")=1004.96
D
EX STORM MH
RIM=1022.39
FL(S 15")=1018.49(DEMO)
FL(W 15")=1018.39
FL(E 18")=1018.34
F/OT
EX INTAKE
T/C=1025.69
GUT=1024.97
EX INTAKE
T/C=1022.22
GUT=1021.72
F/O
3" TREE
EX ROCK EX ROCK
ST 15
"
EX CONCRETE
EX CONCRETE
EX
C
O
N
C
R
E
T
E
S
I
D
E
W
A
L
K
ST
15"
SE
B
R
I
C
K
D
R
I
V
E
(C
O
N
C
R
E
T
E
P
U
B
L
I
C
R
O
A
D
-
8
0
'
R
.
O
.
W
.
)
SE STONE RIDGE DR
(CONCRETE PUBLIC ROAD - 70' R.O.W.)
SE
W
A
C
O
P
L
A
C
E
(C
O
N
C
R
E
T
E
P
U
B
L
I
C
R
O
A
D
-
1
0
0
'
R
.
O
.
W
.
)
LOT 3 LOT 4
LOT 7 LOT 6 LOT 5
(2
3
3
.
3
2
'
)
(R=25.00' Δ=90°0'0" L=39.27'
CH=33.58' N45°8'0"E)
(213.57')(188.51')
(213.58')(213.58')
(2
5
8
.
2
2
'
)
(2
3
3
.
1
5
'
)
(213.57')
(2
5
8
.
2
2
'
)
(213.57')(213.57')(213.57')
(2
5
8
.
2
2
'
)
(2
5
8
.
2
2
'
)
(2
5
8
.
2
2
'
)
(2
5
8
.
2
2
'
)
(R=25.00' Δ=90°8'55" L=39.33'
CH=33.40' S44°47'33"E)
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
EX LOCATION PER
AUREON & UPN MAPS
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
EX LOCATION PER
CENTURYLINK MAP
F/
O
F/
O
F/
O
F/O
F/O F/O F/O F/O F/O F/O F/O
F/
O
F/
O
F/
O
EX LOCATION PER
CENTURYLINK MAP
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
EX LOCATION PER
MEDIACOM MAP
U
/
E
U
/
E
U/E U/E U/E U/E U/E
U/
E
U/
E
U/
E
U/E U/E U/E U/E U/E U/E U/E U/E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
EX LOCATION PER
MIDAMERICAN MAP
EX LOCATION PER
MIDAMERICAN MAP
U/
E
U/
E
U/E
U/
E
U/
E
U/
E
U/E
U/E U/E U/E
U/E
U/E U/E U/E
U/E
U/E U/E U/E
ST 15"ST 15"ST 15"ST 18"ST 18"ST 18"ST 18"ST 42"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
D
ST
15
"
ST 48"ST 48"ST 48"ST 48"
SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"
SEX LOCATION PER
CITY MAP & AERIAL
SA
N
8"
SA
N
8"
SA
N
8"
SA
N
8"
SA
N
8"
EX SERVICE STUBS
PER CITY MAP
W12
"
W12
"
W
12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
EX WATER LINE LOCATION
PER CITY OF WAUKEE GIS
W 12"W 12"W12"W12"W12"W12"W12"W12"W12"W12"W12"W12"W12"W12"
W6"
EX WATER LOCATIONS PER
CITY OF WAUKEE GIS
W6"
W6"
W 6"
W 6"
W
6
"
D
ST
8"
ST
8"
S
T
8
"
ST 15"
ST
18
"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G 2"G 2"G 2"G 2"G 2"G 2"G 2"G 2"G 2"G 2"
G
2"
G 2"G 2"G 2"G 2"G 2"G 2"
G
G
SA
N
8"
EX SERVICE
STUB PER CITY GIS
25
'
B
U
I
L
D
I
N
G
S
E
T
B
A
C
K
L
I
N
E
25' BUILDING SETBACK LINE
25' BUILDING SETBACK LINE
25
'
B
U
I
L
D
I
N
G
S
E
T
B
A
C
K
L
I
N
E
25' BUILDING SETBACK LINE
25' BUILDING SETBACK LINE
25
'
B
U
I
L
D
I
N
G
S
E
T
B
A
C
K
L
I
N
E
25
'
B
U
I
L
D
I
N
G
S
E
T
B
A
C
K
L
I
N
E
25' PRIVATE SANITARY
SEWER EASEMENT
BK. 2007 PG. 15331
10' PUBLIC UTILITY EASEMENT
BK.2007 PG.15339
PRIVATE 15'
STORM SEWER EASEMENT
BK. 2007 PG. 15336
30
'
P
R
I
V
A
T
E
IN
G
R
E
S
S
/
E
G
R
E
S
S
EA
S
E
M
E
N
T
BK
.
2
0
0
7
P
G
.
1
5
3
3
3
30
'
P
R
I
V
A
T
E
IN
G
R
E
S
S
/
E
G
R
E
S
S
EA
S
E
M
E
N
T
BK
.
2
0
0
7
P
G
.
1
5
3
3
3
25' PUBLIC STORM SEWER
AND OVERLAND
FLOWAGE EASEMENT
BK. 2007 PG. 15337
1
5
'
P
R
I
V
A
T
E
S
T
O
R
M
S
E
W
E
R
E
A
S
E
M
E
N
T
B
K
.
2
0
0
7
P
G
.
1
5
3
3
6
PRIVATE 15'
STORM SEWER
EASEMENT
BK. 2007 PG. 15329
15
'
P
R
I
V
A
T
E
W
A
T
E
R
M
A
I
N
E
A
S
E
M
E
N
T
BK
.
2
0
0
7
P
G
.
1
5
3
3
2
10' PUBLIC UTILITY EASEMENT
BK.2007 PG.15339
7.
5
'
P
U
B
L
I
C
S
T
O
R
M
SE
W
E
R
E
A
S
E
M
E
N
T
BK
.
2
0
0
7
P
G
.
1
5
3
3
8
65
'
P
R
I
V
A
T
E
O
V
E
R
L
A
N
D
FL
O
W
A
G
E
A
N
D
D
E
T
E
N
T
I
O
N
EA
S
E
M
E
N
T
BK
.
2
0
0
7
P
G
.
1
5
3
2
8
55,127 SF 54,979 SF
55,143 SF
55,152 SF55,047 SF
WV
WV
EX 48" FES
FL=1017.06
6" TREE
6" PINE6" TREE6" PINE6" PINE
D
EX STORM MH
RIM=1032.11
FL(SW 24")=1021.71
FL(S 48")=1018.61
FL(E 48")=1018.46
ST
(189.25')
W8"W8"W8"W8"W8"
LOT 2
55,071 SF
ST
42
"
ST
42
"
ST
42
"
EX. SW-505 INTAKE
T/C=1021.75
GUT=1021.25
FL(S)=1017.32
100YR HWEL=1021.77
(PER 2018 BE DESIGN
REF. PROJECT #180108)
EX. 15" FES
FL=1016.60
(PER 2018 BE DESIGN
REF. PROJECT #180108)
EX. SW-505 INTAKE
T/C=1021.10
GUT=1020.60
FL(S)=1017.22
100YR HWEL=1021.13
(PER 2018 BE DESIGN
REF. PROJECT #180108)
EX. 15" FES
FL=1016.60
(PER 2018 BE DESIGN
REF. PROJECT #180108)
EX STORM MH
RIM=1021.96
FL(S,N)=1016.56
S
EX SAN MH
RIM=1021.20
INV(S)=1001.38
INV(W)=1001.20
INV(S)=1001.04
EX INTAKE
T/C=1017.01
FL(N,S)=1011.02
EX STORM MH
RIM=1017.21
FL(S)=1011.26
FL(W)=1011.03
FL(N)=1011.03
D D
D
S
D
ST
42"
ST
42
"
ST
42
"
ST
42
"
ST
42
"
ST
42
"
ST
42
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST 15"
ST 15"
EX STORM MH
RIM=1020.92
EX STORM MH
RIM=1022.17
FL(E)=1016.47
FL(S)=1014.85
FL(N)=1014.97
EX INTAKE
T/C=1021.68
FL(E)=1017.18
FL(W)=1017.15
EX INTAKE
T/C=1021.42
FL(W)=1016.97
EX STORM MH
RIM=1024.81
FL(S)=1016.70
FL(N)=1016.41
EX INTAKE
T/C=1024.82
FL(E,W)=20.89
EX INTAKE
T/C=1024.77
FL(E)=10021.37
EX INTAKE
T/C=1024.77
EX INTAKE
T/C=1024.77
EX 15" FES
FL=1021.96
EX STORM MH
RIM=1024.89
FL(N,S)=1019.16
S
S
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
S
A
N
1
0
"
S
A
N
1
0
"
S
A
N
1
0
"
SAN10"
SA
N
10
"
HY D
WV
WV
H Y D
W
W
W
W
W
W
W
W
W
W
G
G
G
G
G
G
G
G
G
G
G
G
G
G
U/E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
EX INTAKE
T/C=1017.02
EX INTAKE
T/C=1017.00
FL(S)=1010.82
EX STORM MH
RIM=1017.76
4" TREE
4" TREE
4" TREE
4" TREE
4" TREE
4" TREE
4" TREE
4" TREE
4" TREE
ST
8"
ST
8"
ST
15"
S
T
1
5
"
D
EX. SW-502
T/C=1020.75
GUT=1020.25
FL(SW, SE)=1014.21
FL(N)=1014.11
100YR HWEL=1020.61
EX. SW-401 W/DOME INTAKE
GRATE
RIM=1023.40
FL(SE)=1015.35
FL(NW)=1015.25
EX. INTAKE
T/C=1022.90
GUT=1022.40
FL(S)=1016.42
FL(N)=1016.32
100YR HWEL=1022.68
EX. 8" DRAIN BASIN
W/DOME GRATE
RIM=1022.70
FL(N)=1017.32
EX. 8" DRAIN BASIN
W/DOME GRATE
RIM=1022.70
FL(N)=1018.18
REGIONAL DETENTION POND
100-YR HWEL = 1020.48
102
7
1028
1
0
2
6
1025
1
0
2
6
1
0
2
7
1
0
2
9
1
0
3
0
1
0
3
1
1
0
3
0
10
2
9
10
2
5
1020
1017
10
1
7
10
2
0
102
5
1
0
2
1
102
1
102
2
10
2
2
10
2
5
1023
10
2
3
1024
1
0
2
3
1025
10
2
5
10
2
5
10
2
3
1
0
2
0
1
0
1
9
1017
1
0
2
0
1
0
2
1
1
0
2
2
10
2
2
1
0
2
0
102210
2
3
1
0
2
5
10
3
1
10
3
0
10
2
9
1
0
2
8
1
0
2
7
10
2
4
10
2
3
1021
1020
101
9
101
8
10
1
7
1017
101
8
10
1
9
1019
1020
1021
10
2
2
1023
1022
10
2
3
10
2
3
10
2
5
1
0
2
5
1
0
2
5
102
5
1
0
2
3
1
0
2
2
1
0
2
1
10
2
1
102
0
10
2
3
10
2
3
1022
1
0
2
2
1020
1017
10
2
6
1
0
2
6
10
2
5
10
2
4
10
2
3
10
2
2
10
2
1
1
0
2
0
10
1
9
10
1
8
10
1
7
1
0
1
8
1
0
1
9
10
2
2
10
2
4
1
0
2
3
10
2
3
102
4
1
0
2
5
1
0
2
3
10
2
3
1022
1022
10
2
3
10
2
2
10
3
1
1024.33
1024.60 1024.60
1025.00
100 YEAR PONDING
ELEV. = 1020.48
30' PRIVATE
INGRESS/EGRESS
EASEMENT
BK. 2007 PG. 15333
25
N: 588182.14
E: 1545274.84
ELEV: 1024.61
CP 3/4 IP RPC
26
N: 588198.62
E: 1545924.80
ELEV: 1020.66
CP 3/4 IP RPC
27
N: 588181.34
E: 1545646.71
ELEV: 1019.82
CP 3/4 IP RPC
9012
N: 587623.67
E: 1545244.24
ELEV: 1031.96
CP PPC
9013
N: 587580.00
E: 1545915.70
ELEV: 1026.14
CP CUT X
9014
N: 587858.53
E: 1545489.51
ELEV: 1024.78
CP CUT X
EX 24" FES
FL=1016.84
EX 18" FES
FL=1016.93
REMOVE EX.
TREE, TYP.
REMOVE EX.
WATER VALVE
REMOVE EX. FES &
CAP PIPE W/
FLOWABLE MORTAR
REMOVE EX.
FES & PIPE
PROTECT EX. UTILITY
STRUCTURES & LINES
PROTECT
EX.SANI
SWR STUB
PROTECT EX.
UTILITY LINESPROTECT EX.
WATER VALVE
& SERVICE
PROTECT EX. UTILITY
STRUCTURES & LINES
PROTECT EX.
UTILITY LINES REMOVE
EX. SANI
SWR LINE
PROTECT EX. SANI
SWR MANHOLE
REMOVE EX. SANI SWR
MANHOLE & LINES
REMOVE EX.
TREE, TYP.
PROTECT
EX. TREE,
TYP.
PROTECT
EX. TREE,
TYP.
PROTECT
EX. LIGHT
POLE, TYP.
REMOVE
EX. LIGHT
POLE, TYP.
PROTECT
EX. HYDRANT
ASSEMBLY
PROTECT & ADJUST EX. F/O
STRUCTURES TO GRADE
(CONTRACTOR TO
COORDINATE W/ OWNER &
UTILITY PROVIDER)
PROTECT
EX. 36"
STORM PIPE
EX. 30' PRIVATE
INGRESS/EGRESS
EASEMENT TO BE
VACATED
EX. 30' PRIVATE
INGRESS/EGRESS
EASEMENT TO BE
VACATED
EX. 25' PRIVATE
SANITARY SEWER
EASEMENT TO BE
VACATED
PROTECT EX. UTILITY
STRUCTURES & LINES
PROTECT EX. FES
& 48" STORM PIPE
PROTECT EX.
F/O STRUCT.
PROTECT
EX. HYDRANT
ASSEMBLY
EX. 15' PRIVATE
STORM SEWER
EASEMENT TO BE
VACATED
REMOVE
EX. PAVEMENT
REMOVE
EX. PAVEMENT
PROTECT
EX. STORM
INTAKE & PIPE
PROTECT
EX. TREE,
TYP.
REMOVE
EX. STRIPE, TYP.
REMOVE
EX. STRIPE,
TYP.
REMOVE
EX. STRIPE, TYP.
PROTECT
EX. STRIPE, TYP.
PROTECT
EX. 36"
STORM PIPE
PROTECT EX.
WATER LINE
PROTECT EX.
UTILITY LINES
PROTECT EX. UTILITY
STRUCTURE & LINES
PROTECT EX.
F/O STRUCT.
REMOVE
EX. STRIPE, TYP.
REMOVE
EX. STRIPE, TYP.
REMOVE
EX. STRIPE, TYP.
REMOVE &
REPLACE EX.
PAVEMENT,
RAMP & LANDING
REMOVE
EX. ISLAND
PROTECT
EX. STRIPE,
TYP.
PROTECT
EX. STRIPE, TYP.
PROTECT
EX. STORM
INTAKE & PIPE
REMOVE
EX. PAVEMENT,
CURB & GUTTER
EX. 15' PRIVATE
STORM SEWER
EASEMENT TO BE
VACATED
PLUG SOUTH
OPENING WITH
WATER TIGHT PLUG
GRIND DOWN
EX. CURB
80'
REMOVE
EX. TREE,
TYP.
DEMO WATER
SERVICE LINE
AND CAP AT MAIN
PER CITY CODE.
COORDINATE WITH
CITY STAFF.
REMOVE
EX. ISLAND
EX. 30' PRIVATE
INGRESS/EGRESS
EASEMENT TO BE
VACATED
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
#
IS
S
U
E
D
A
T
E
NB
I
#
:
-
-
-
-
-
-
-
-
DB
S
#
:
2
2
-
3
-
4
4
2
DR
A
W
N
B
Y
:
G
S
A
CH
E
C
K
E
D
B
Y
:
S
V
S
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
#
IS
S
U
E
D
A
T
E
ST
I
V
E
R
S
GE
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
-
A
R
C
H
I
T
E
C
T
14
3
5
o
h
i
o
s
t
r
e
e
t
/
p
.
o
.
b
o
x
1
3
1
5
/
d
e
s
m
o
i
n
e
s
,
i
a
5
0
3
0
5
-
1
3
1
5
ph
o
n
e
:
(
5
1
5
)
2
4
3
-
0
1
5
6
/
f
a
x
:
(
5
1
5
)
2
4
3
-
0
1
6
5
NE
U
M
A
N
N
B
R
O
T
H
E
R
S
,
I
N
C
.
-
D
E
S
I
G
N
B
U
I
L
D
S
O
L
U
T
I
O
N
S
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Copyright DesignBuild Solutions, LC. Protected under Architectural Works Copyright Protection Act of 1990.
FIELD BULLETINS
ASSOCIATED WITH
THIS SHEET:
01
/
1
1
/
2
0
2
3
1S
T
C
I
T
Y
S
U
B
M
I
T
T
A
L
04
/
0
6
/
2
0
2
3
2N
D
C
I
T
Y
S
U
B
M
I
T
T
A
L
06
/
1
6
/
2
0
2
3
3R
D
C
I
T
Y
S
U
B
M
I
T
T
A
L
08
/
2
8
/
2
0
2
3
4T
H
C
I
T
Y
S
U
B
M
I
T
T
A
L
09
/
1
3
/
2
0
2
3
5T
H
C
I
T
Y
S
U
B
M
I
T
T
A
L
12
/
1
9
/
2
0
2
2
5
:
0
0
:
1
3
P
M
FO
R
D
P
R
O
C
E
N
T
E
R
13
5
0
S
E
S
t
o
n
e
R
i
d
g
e
D
r
i
v
e
,
W
a
u
k
e
e
,
I
o
w
a
5
0
2
6
3
GRAPHIC SCALE
030 15 30 60
L:
\
L
A
N
D
P
R
O
J
E
C
T
S
2
0
2
2
\
2
2
0
3
2
8
\
D
W
G
\
C
1
E
X
.
C
O
N
D
I
T
I
O
N
S
&
D
E
M
O
.
D
W
G
9/
1
3
/
2
0
2
3
1
:
5
6
:
2
0
P
M
DEMO NOTES:
1.SAWCUT & REMOVE ALL PAVEMENT TO FULL DEPTH OF SLAB.
2.PROTECT ALL TREES NOT CALLED OUT FOR REMOVAL WITH
ORANGE CONSTRUCTION FENCE AT THE DRIP LINE.
3.PAVEMENT STRIPING CALLED OUT FOR REMOVAL SHALL BE
SANDBLASTED. NO GRINDING WILL BE ALLOWED.
4.CONTRACTOR TO LOCATE AND VERIFY ALL EXISTING UTILITY
LOCATIONS AND DEPTH ON SITE PRIOR TO CONSTRUCTION
AND CONTACT ENGINEER/OWNER IF DIFFERENT FROM PLANS
OR IN CONFLICT WITH CONSTRUCTION ACTIVITIES.
5.CONTRACTOR TO COORDINATE PERMITTING, SIGNAGE AND
LANE CLOSURE WITH CITY AS REQUIRED FOR WORK WITHIN
RIGHT OF WAY PRIOR TO START OF CONSTRUCTION.
6.CONTRACTOR TO PROTECT ALL UTILITIES, PAVEMENTS AND
STRUCTURES THAT ARE NOT SCHEDULED FOR REMOVAL.
CONTRACTOR SHALL REPAIR AND/OR REPLACE ANY DAMAGED
UTILITIES, PAVEMENTS, AND STRUCTURES NOT SCHEDULED
FOR REMOVAL PER CITY/OWNER SPECIFICATIONS AT THE
CONTRACTORS EXPENSE.
7.CONTRACTOR TO REMOVE EXISTING TEMPORARY GRANULAR
SURFACE AND UNSUITABLE MATERIALS WITHIN REMOVAL
LIMITS SHOWN AND HAUL OFF TO AN APPROVED LOCATION.
8.CONTRACTOR TO COORDINATE WITH OWNER FOR SALVAGING
& STORING MATERIALS AT A LOCATION DESIGNATED BY THE
OWNER.
9.CONTRACTOR TO COORDINATE WITH UTILITY OWNERS AND
MEP FOR ANY REQUIRED RELOCATION OR ADJUSTMENT OF
EXISTING FIBER, ELECTRIC AND GAS LINES AS NEEDED TO
AVOID CONFLICT WITH CONSTRUCTION ACTIVITIES AND
IMPROVEMENTS.
10.THIS PROJECT INCLUDES SAWCUTTING OR CONCRETE
GRINDING SO PROTECTION OF STORM SEWERS AND
DRAINAGE WAYS WILL NEED TO BE PROVIDED FROM SLURRY
FROM THE CONCRETE OPERATIONS TO DISCHARGE OFFSITE.
SEE SWPPP SHEET AND NARRATIVE FOR ADDITIONAL DETAILS.
DEMO LEGEND:
PAVEMENT
REMOVAL LIMITS
DENOTES PROTECTION
DENOTES REMOVAL
C1.1
EX. CONDITIONS
& DEMO PLAN
5,670 SF
FUTURE
DISPLAY
ROOM
PROP. BUILDING
PROP. 34,150 SQ. FT.
FF=1023.50'
HT.=23.00
30'
HEAVY DUTY PAVEMENT
(REF. DETAIL 1/C6.1)
12'
8'
3'
12'
10
'
9
36
'
10'
10'
4
5" PCC
WALK
8'5'8'32
'
5
R1'
R
1
'
DRIVEWAY
5"
P
C
C
T
U
R
N
E
D
D
O
W
N
W
A
L
K
SAWCUT PAVEMENT
& MATCH EX.
SA
W
C
U
T
P
A
V
E
M
E
N
T
&
M
A
T
C
H
E
X
.
SAWCUT PAVEMENT & MATCH EX.
SA
W
C
U
T
P
A
V
E
M
E
N
T
T
O
CL
E
A
N
E
D
G
E
&
M
A
T
C
H
E
X
.
30'
HE
A
V
Y
D
U
T
Y
P
A
V
E
M
E
N
T
(R
E
F
.
D
E
T
A
I
L
1/C6
.
1
)
HEAVY DUTY PAVEMENT
(REF. DETAIL 1/C6.1)
HE
A
V
Y
D
U
T
Y
P
A
V
E
M
E
N
T
(R
E
F
.
D
E
T
A
I
L
1/C6
.
1
)
70.0'
70.0'
81
.
0
'
81
.
0
'
8'
5'
24
'
10
.
5
'
26
'
18'
24
'
10
.
5
'
20
'
18'
1,
7
4
5
S
F
P
R
O
P
.
DE
T
E
N
T
I
O
N
&
R
A
I
N
GA
R
D
E
N
WV
10'10.5'
A/
C
6'
R
2
5
'
TRASH
ENCLOSURE
(REF. ARCH)
OIL TANKER
STALLS
ADA RAMP
ADA
RAMP
ADA LANDING
4" PAINTED
LINE, TYP.PAINTED ADA
STALL PER
ADAAG, TYP.
PAINTED ADA
SYMBOL, TYP.
PAINTED
ISLAND, TYP.
CURB STOP,
TYP.
EV RAPID
CHARGING
STATION &
BOLLARDS, TYP.
STRUCTURAL
STOOP, TYP.
(REF. ARCH &
STRUCT)
STRUCTURAL
STOOP, TYP.
(REF. ARCH &
STRUCT)
STRUCTURAL
STOOP, TYP.
(REF. ARCH &
STRUCT)
STRUCTURAL
STOOP, TYP.
(REF. ARCH &
STRUCT)
PAINTED
ISLAND, TYP.
PAINTED
ISLAND, TYP.SAWCUT
PAVEMENT &
MATCH EX.
SAWCUT &
MATCH EX.
MATCH EX. MATCH EX.
OVERHEAD DOOR, TYP.
(REF. ARCH & STRUCT)
OVERHEAD DOOR, TYP.
(REF. ARCH & STRUCT)
OVERHEAD DOOR, TYP.
(REF. ARCH & STRUCT)OVERHEAD DOOR, TYP.
(REF. ARCH & STRUCT)
BOLLARD, TYP.
(REF. ARCH)
BOLLARD W/
PROXIMITY CARD
READER
(REF. ARCH)
BOLLARD, TYP.
(REF. ARCH)BOLLARD, TYP.
(REF. ARCH)
5" PCC TURNED
DOWN WALK
BOLLARD W/
PROXIMITY CARD
READER
(REF. ARCH)
BOLLARD, TYP.
(REF. ARCH)
AC UNITS ON CONC.
PAD W/ BOLLARDS
(REF. ARCH & ELEC.)
R5'
FF=1023.50
(PER 2018 DESIGN
REF. PROJECT #180108)8'
HYD
HYD
H Y D
TRANSFORMER ON
CONC. PAD
(REF. ELEC & ARCH)
FUTURE
GENERATOR ON
CONC. PAD AREA
(REQUIRED TO BE
SCREENED)
OVERHEAD DOOR, TYP.
(REF. ARCH & STRUCT)
TAPER TO
NO CURB IN
10'
TAPER TO
NO CURB
TAPER TO
NO CURB IN
10'
SAWCUT &
MATCH EX.ADJUST RIM
TO GRADE
ADJUST RIM
TO GRADE
ADJUST RIM
TO GRADE
ADJUST RIM
TO GRADE
ADJUST RIM
TO GRADE
ADJUST RIM
TO GRADE
DETECTABLE
PANEL
ADA RAMP W/
DETECTABLE
PANELS &
5'X5' LANDING
D
D
R2
5
'
4.
5
'
4.
5
'
1'
1'
10.75'
5" PCC SIDEWALK5" PCC SIDEWALK 5'
5'
5'
5"
PC
C
S
I
D
E
W
A
L
K
5'
5"
PC
C
S
I
D
E
W
A
L
K
33
'
CO
CO CO
CO
ADA RAMP W/
DETECTABLE
PANELS &
5'X5' LANDING
MATCH EX.
MATCH EX.
MATCH EX.
MATCH EX.
MATCH EX.
43'
23
12
11
15
15
15
27
R
4
'R4'
R
4
'R4'
R15'
R
5
'
9'
30' SETBACK 30' SETBACK
30' SETBACK30' SETBACK
PROPOSED LOT 1
AREA = 110,122.89
PROPOSED LOT 2
AREA = 220,398.72 SF 49
1
.
3
9
'
213.57'
51
6
.
3
6
'
188.51'
L=39.16'
402.83'
R=25.00' Δ=90°05'55"
L=39.31' CH=35.39'
S45°08'51"W
49
1
.
3
1
'
426.36'
WILLI
A
M
S
P
O
I
N
T
E
P
L
A
T
1
6
WILLI
A
M
S
P
O
I
N
T
E
P
L
A
T
1
6
SUDAS TYPE 'A'
DRIVEWAY
(REF. DETAIL 1/C6.2)
EX. SUDAS TYPE
'A' DRIVEWAY
200.51'
13
7
.
5
0
'
36.50'
41
.
0
0
'
85.62'
0.24'
75.12'
47
.
2
0
'
3.27'
13
1
.
5
4
'
5"
PC
C
S
I
D
E
W
A
L
K
ADA RAMP W/
DETECTABLE
PANELS & 5'X5'
LANDING
5'
5'
8'8'
5'
5'
CO
18
'
2
SAWCUT &
MATCH EX.
9'
4" PAINTED
LINE, TYP.
10.13'
R5'
R
1
5
'
18
'
10'10.5'
10
'
10
'
6'
R15'
R
5
'
8'
5'
67
'
6'
8'
12.
5
'
5' CURB
OPENING
12'
12'
32
'
R
4
'
R9'
60°
18
'
10.5'
12'
12.5'12'
R5
'R5'
R
2
5
'
R5'
43
.
1
9
'
5' CURB
OEPNING
10.5'
CO
CO
S
R5
'
HEAVY DUTY PAVEMENT
(REF. DETAIL 1/C6.1)
79
.
0
0
'
N0
0
°
2
0
'
0
6
"
E
79
.
0
0
'
S0
0
°
2
0
'
0
6
"
W
32.00'
N89°49'20"W
32.00'
S89°49'20"E
INGRESS/EGRESS
EASEMENT
BOLLARD, TYP.
(REF. ARCH)
FDC
(REF. ARCH)
R5
'
R25'
R5'R
5
'
R
2
'
R2'
R
4
'
R4'
R4'R
4
'
SAWCUT &
MATCH EX.
TAPER TO
NO CURB IN
TAPER TO
NO CURB IN
TAPER TO
NO CURB IN
3" CURB
COCO CO
CO
23 TONS CLASS "E"
RIP-RAP W/ ENG. FABRIC
(REF.DETAIL 2, C6.2)
CO CO
MATCH EX.
18 TONS CLASS "E"
RIP-RAP W/ ENG.
FABRIC
(REF.DETAIL 2, C6.2)
12 TONS CLASS "E"
RIP-RAP W/ ENG. FABRIC
(REF.DETAIL 2, C6.2)
43 TONS CLASS "E"
RIP-RAP W/ ENG. FABRIC
(REF.DETAIL 2, C6.2)
PAINTED
ISLAND, TYP.
35 TONS CLASS "E"
RIP-RAP W/ ENG. FABRIC
(REF.DETAIL 2, C6.2)
MATCH EX.
4" RIVER ROCK W/
ENG. FABRIC
STEEL EDGER
OVERFLOW ROUTE
ELEV. = 1017.56
9
'
10'
9.46'
9.38'
9.42'
14 TONS CLASS "E"
RIP-RAP W/ ENG. FABRIC
(REF.DETAIL 2, C6.2)
14'
10
'
229.43'110.47'
50
3
.
3
2
'
49
9
.
1
5
'
9
.
8
8
'
1
0
.
1
2
'
R5'
CO
CO
10'
13
'
21'
23
'
1
6
'
18'
16
'
16'
13
'
15 TONS CLASS "E"
RIP-RAP W/ ENG. FABRIC
(REF. DETAIL 2, C6.2)
11
'
12'
72.47'
21
.
7
9
'
210.73'
5.
0
4
'
23
.
8
2
'
65.19'
5'5'
87
'
20'
100-YR PONDING ELEV. = 1020.43
OVERFLOW ROUTE
ELEV. = 1019.02
PRIVATE
WATERMAIN
EASEMENT
SAWCUT &
MATCH EX.
SAWCUT &
MATCH EX.
30.00'
S89°48'24"E
32
.
0
0
'
N0
0
°
2
0
'
0
6
"
E
30.00'
N89°48'24"W
32
.
0
0
'
S0
0
°
2
0
'
0
6
"
W
D
R5'R5'
60°
WV
H Y D
F/OF/O
F/OFO
D
D
WV
H Y D
F/O
WV
WV
WV
H Y D
FO
3" TREE
D
SS
D
F/OT
F/O
EX ROCK
EX CONCRETE
EX CONCRETE
EX
C
O
N
C
R
E
T
E
S
I
D
E
W
A
L
K
ST
15"
SE
B
R
I
C
K
D
R
I
V
E
(C
O
N
C
R
E
T
E
P
U
B
L
I
C
R
O
A
D
-
8
0
'
R
.
O
.
W
.
)
SE STONE RIDGE DR
(CONCRETE PUBLIC ROAD - 70' R.O.W.)
80'
R.O.W.
70
'
R.
O
.
W
.
100'
R.O.W.
SE
W
A
C
O
P
L
A
C
E
(C
O
N
C
R
E
T
E
P
U
B
L
I
C
R
O
A
D
-
1
0
0
'
R
.
O
.
W
.
)
OWNER: ALICE PLACE LP
ZONED: R-3 (RENTAL MULTI-FAMILY RESIDENTIAL
DISTRICT) & PD (PLANNED DEVELOPMENT)
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/O
F/O F/O F/O F/O F/O F/O F/O
F/
O
F/
O
F/
O
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
ST 15"ST 15"ST 15"ST 18"ST 18"ST 18"ST 18"ST 42"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
D
ST 48"ST 48"ST 48"ST 48"
SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"
S
W12
"
W12
"
W
12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W 12"W 12"W12"W12"W12"W12"W12"W12"W12"W12"W12"W12"W12"W12"
W6"
W6"
W6"
W 6"
W 6"
W
6
"
D
ST
8"
ST
8"
S
T
8
"
ST 15"
ST
18
"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G 2"G 2"G 2"G 2"G 2"G 2"G 2"G 2"G 2"G 2"
G
2"
G 2"G 2"G 2"G 2"G 2"G 2"
G
G
SA
N
8"
10' PUBLIC UTILITY EASEMENT
BK.2007 PG.15339
25' PUBLIC STORM SEWER
AND OVERLAND
FLOWAGE EASEMENT
BK. 2007 PG. 15337
PRIVATE 15'
STORM SEWER
EASEMENT
BK. 2007 PG. 15329
15
'
P
R
I
V
A
T
E
W
A
T
E
R
M
A
I
N
E
A
S
E
M
E
N
T
BK
.
2
0
0
7
P
G
.
1
5
3
3
2
10' PUBLIC UTILITY EASEMENT
BK.2007 PG.15339
7.
5
'
P
U
B
L
I
C
S
T
O
R
M
SE
W
E
R
E
A
S
E
M
E
N
T
BK
.
2
0
0
7
P
G
.
1
5
3
3
8
65
'
P
R
I
V
A
T
E
O
V
E
R
L
A
N
D
FL
O
W
A
G
E
A
N
D
D
E
T
E
N
T
I
O
N
EA
S
E
M
E
N
T
BK
.
2
0
0
7
P
G
.
1
5
3
2
8
WV
6" TREE
6" PINE6" TREE6" PINE6" PINE
D
ST
W8"W8"W8"W8"W8"
ST
42
"
ST
42
"
ST
42
"
S
D D
D
S
D
ST
42"
ST
42
"
ST
42
"
ST
42
"
ST
42
"
ST
42
"
ST
42
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST 15"
ST 15"
S
S
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
S
A
N
1
0
"
S
A
N
1
0
"
S
A
N
1
0
"
SAN10"
SA
N
10
"
HY D
WV
WV
H Y D
W
W
W
W
W
W
W
W
W
W
G
G
G
G
G
G
G
G
G
G
G
G
G
G
4" TREE
4" TREE
4" TREE
4" TREE
4" TREE
4" TREE
4" TREE
4" TREE
4" TREE
ST
8"
ST
8"
ST
15"
S
T
1
5
"
D
REGIONAL DETENTION POND
100-YR HWEL = 1020.48
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
#
IS
S
U
E
D
A
T
E
NB
I
#
:
-
-
-
-
-
-
-
-
DB
S
#
:
2
2
-
3
-
4
4
2
DR
A
W
N
B
Y
:
G
S
A
CH
E
C
K
E
D
B
Y
:
S
V
S
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
#
IS
S
U
E
D
A
T
E
ST
I
V
E
R
S
GE
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
-
A
R
C
H
I
T
E
C
T
14
3
5
o
h
i
o
s
t
r
e
e
t
/
p
.
o
.
b
o
x
1
3
1
5
/
d
e
s
m
o
i
n
e
s
,
i
a
5
0
3
0
5
-
1
3
1
5
ph
o
n
e
:
(
5
1
5
)
2
4
3
-
0
1
5
6
/
f
a
x
:
(
5
1
5
)
2
4
3
-
0
1
6
5
NE
U
M
A
N
N
B
R
O
T
H
E
R
S
,
I
N
C
.
-
D
E
S
I
G
N
B
U
I
L
D
S
O
L
U
T
I
O
N
S
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Copyright DesignBuild Solutions, LC. Protected under Architectural Works Copyright Protection Act of 1990.
FIELD BULLETINS
ASSOCIATED WITH
THIS SHEET:
01
/
1
1
/
2
0
2
3
1S
T
C
I
T
Y
S
U
B
M
I
T
T
A
L
04
/
0
6
/
2
0
2
3
2N
D
C
I
T
Y
S
U
B
M
I
T
T
A
L
06
/
1
6
/
2
0
2
3
3R
D
C
I
T
Y
S
U
B
M
I
T
T
A
L
08
/
2
8
/
2
0
2
3
4T
H
C
I
T
Y
S
U
B
M
I
T
T
A
L
09
/
1
3
/
2
0
2
3
5T
H
C
I
T
Y
S
U
B
M
I
T
T
A
L
12
/
1
9
/
2
0
2
2
5
:
0
0
:
1
3
P
M
FO
R
D
P
R
O
C
E
N
T
E
R
13
5
0
S
E
S
t
o
n
e
R
i
d
g
e
D
r
i
v
e
,
W
a
u
k
e
e
,
I
o
w
a
5
0
2
6
3
GRAPHIC SCALE
030 15 30 60
L:
\
L
A
N
D
P
R
O
J
E
C
T
S
2
0
2
2
\
2
2
0
3
2
8
\
D
W
G
\
C
2
L
A
Y
O
U
T
.
D
W
G
9/
1
3
/
2
0
2
3
1
:
5
6
:
4
0
P
M
GENERAL NOTES:
1.CONTRACTOR TO PROVIDE GRADATION TESTING FOR
EVERY 200 TONS OF GRANULAR MATERIAL DELIVERED
TO THE SITE GRADATION TESTING IS TO BE CONDUCTED
AND REVIEWED BY GEOTECHNICAL FIRM PRIOR TO
GRANULAR MATERIAL BEING INSTALLED.
2.GEOTECHNICAL REPORT FOR SITE WAS NOT PROVIDED
BY OWNER.
3.THE DESIGN AND SPECIFICATIONS IN THE APPROVED
CONSTRUCTION DOCUMENTS ARE BASED ON TYPICAL
CONDITIONS AND ARE NOT BASED ON
RECOMMENDATIONS FROM SITE SPECIFIC
GEOTECHNICAL REPORT.
4.THE RECOMMENDED DESIGN AND SPECIFICATIONS HAVE
BEEN APPROVED BY THE OWNER.
5.ANY RECOMMENDATIONS MADE BY THE OWNER'S
SELECTED GEOTECHNICAL FIRM SHALL GOVERN.
6.IF GRANULAR MATERIAL ARE INSTALLED THAT DO NOT
MEET THE OWNER'S SELECTED GEOTECHNICAL FIRM
SPECIFICATIONS. THE CONTRACTOR, SHALL AT THEIR
OWN EXPENSE, REMOVE AND REPLACE THE DEFICIENT
GRANULAR MATERIAL PER SPECIFICATION.
7.ALL SIGNAGE SHALL RECEIVE SEPARATE APPROVALS
WITH A SIGNED PERMIT APPLICATION FROM THE CITY OF
WAUKEE COMMUNITY DEVELOPMENT DEPARTMENT.
8.ALL BIORETENTION CELLS ARE TO BE CONSTRUCTED
ONLY AFTER ALL OTHER CONSTRUCTION ITEMS ARE
COMPLETE. SEDIMENT PROTECTION WILL BE REQUIRED
IF IMMEDIATE UPSTREAM PROTECTION IS NOT ABLE TO
BE COMPLETED.
PAVEMENT & ASPHALT PLACEMENT NOTES:
1.CONTRACTOR TO CONNECT TO EXISTING PCC
PAVEMENTS WITH IOWA SUDAS TYPICAL BT JOINT.
2.CONTRACTOR TO REPLACE PCC PAVEMENTS FOR
STORM SEWER INSTALLATION PER SUDAS.
3.CONTRACTOR TO REPLACE PAVEMENTS WITH A MINIMUM
THICKNESS THAT IS 1" GREATER THAN THE EXISTING
PAVEMENT THICKNESS.
BUILDING & STRUCTURAL NOTES:
1.SEE FINAL ARCHITECTURAL PLANS FOR BUILDING
DIMENSIONS.
2.CONTRACTOR TO REFER TO ARCHITECTURAL PLANS FOR
DETAILED BUILDING CONSTRUCTION INFORMATION.
3.CONTRACTOR TO REFER TO STRUCTURAL PLANS FOR
DETAILED BUILDING FOUNDATION AND STOOP
LOCATIONS AND DETAILED CONSTRUCTION
INFORMATION.
C2.1
LAYOUT
PLAN
5,670 SF
FUTURE
DISPLAY
ROOM
PROP. BUILDING
PROP. 34,150 SQ. FT.
FF=1023.50'
HT.=23.00
WV
A/
C
FF=1023.50
(PER 2018 DESIGN
REF. PROJECT #180108)
HYD
HYD
H Y D
10
1
9
10
2
0
1
0
3
0
1022
102
2
10
2
3
1022
1018
1
0
2
8
1
0
2
8
1018
1020
10221022
1
0
3
1
1
0
3
2
D
D
1
0
2
2
1
0
2
1
10
2
0
10
2
1
1
0
2
2
1
0
2
5
1.9%
1.9%5.0%
5.0%
CO
CO CO
CO
MATCH EX.
MATCH EX.
30' SETBACK 30' SETBACK
30' SETBACK30' SETBACK
5.8%
6:1
6:1
4.5
%
1.5%
1.5%0.
0
%
1.0%
1.0%
0.
0
%
0.
0
%
1.5%
0.
7
%
0.
0
%
5.
0
%
0.
0
%
0.
0
%
0.
0
%
2.
2
%
2.
2
%
2.
0
%
1.
4
%
1.
4
%
1.
4
%
1.0%
1.2
%
1.0%
1.7%
1.
0
%
0.6%
1.1%
2.6%1.1%
1.0%1.0%
1.0%1.5%
1.
1
%
1.8
%1.
9
%
2.
4
%
0.
9
%
1.6
%
1.
4
%
2.
5
%
1.7%
1.
5
%
0.
8
%
0.
8
%
1.2%
4.
5
%
3.
8
%
0.
6
%
2.1%
1.
7
%
1.
4
%
0.
8
%
0.
8
%
2.
0
%
2.
1
%
1.
2
%
1.5%
1.5%
0.
0
%
1.
8
%
4.7%
1.
0
%
1.0%
1.
0
%
1.
0
%
4.
0
%
1.
5
%
2.0%1.6%
2.0%
2.0
%
1.1%
CO
SEE DETAIL 'C' ON SHEET
C6.2 FOR GRADING
DETAILS IN THIS AREA
SEE DETAIL 'B' ON SHEET
C6.2 FOR GRADING
DETAILS IN THIS AREA
SEE DETAIL 'A' ON SHEET
C6.2 FOR GRADING
DETAILS IN THIS AREA
SEE DETAIL 'D' ON SHEET
C6.2 FOR GRADING
DETAILS IN THIS AREA
2.9
%
1
0
1
9
10
2
2
1024
1
0
2
2
1022.57±EX1022.70±EX1022.91±EX
1022.17±EX
1021.89±EX
1022.44±EX
1022.48±EX
1021.25±EX
1023.16
1023.50
STRUCTURE #14
OVERSPILL
1022.42T/C
1021.92G
1022.45
1022.78T/C
1022.28G 1021.82G
1022.10±EX T/C
STRUCTURE #12
OVERTOPPING
1023.09T/C
1022.59G
1023.92T/C
1023.42G
1023.55T/C
1023.05G
STRUCTURE #6
1022.50T/C
1022.00G
STRUCTURE #6
OVERTOPPING
1023.00T/C
1022.50G
1023.19T/C
1022.69G
1022.37T/C
1021.87G
STRUCTURE #9
OVERTOPPING
1022.45T/C
1021.95G
1021.31
1022.78T/C
1022.28G
1023.23T/C
1022.73G
1023.11T/C
1022.61G
1023.29T/C
1022.79G
1023.29T/C
1022.79G
1023.07T/C
1022.57G
1023.02T/C
1022.52G
1021.77T/C
1021.27G
1021.19
1022.01T/C
1021.51G 1022.24T/C
1021.74G
1022.48T/C
1021.98G
1022.92T/C
1022.42G
1023.09T/C
1022.59G
1023.50
1023.42
1023.50
1023.50
1023.50
1023.50
1023.42
1023.42
1023.50
1023.50
1022.34LP
1022.83HP
1021.55LP
1023.00
1023.50
1023.50
1023.41
1023.29
1023.42E/W
1023.50
1023.19E/W
1023.50
1023.50
1023.38E/W
1023.38E/W
1023.38E/W
1022.511022.61 1022.51
1022.08
1023.19T/C
1022.69G
1023.30T/C
1022.80G
1023.30T/C
1022.80G
1023.30T/C
1022.80G
1022.66±EX 1022.28±EX 1021.96±EX1022.81±EX
1023.08HP
1022.74HP
1023.01T/C
1022.51G
1022.79T/C
1022.29G
1023.50
1022.92E/W
1022.80T/C
1022.30G
1025.07HP
1022.69
1022.78
1022.71T/C
1022.21G
1023.50T/C
1023.25G
1023.31E/W
1023.62T/C
1023.12G
1025.14E/W
1024.55E/W
1024.80E/W
1025.22E/W
1025.14E/W
1032.05E/W
1032.11E/W
STRUCTURE #4
OVERFLOW
1022.10T/C
1021.60G
1022.27T/C
1021.77G
1019.61T/C
1019.11G
1024.14
1025.34
1027.43
1029.09
1032.25
1021.30
1023.50
1023.50
1023.50
1023.29E/W
1023.36E/W
1022.47E/W
1022.55E/W
1023.38E/W
CO
CO
S
1021.97±EX1022.21±EX
1022.02±EX 1021.97±EX
1022.37±EX
1023.08±EX
1022.44±EX
1022.96
1022.48
1022.95T/C
1022.45G
0
.
9
%
1021.38T/C
1020.88G
1022.44T/C
1021.94G
1023.50T/C
1023.25G
1023.50T/C
1023.25G
1023.50T/C
1023.25G
1023.50T/C
1023.25G
1023.50
MATCH EX.
MATCH EX.
1.
2
%
1.0%
1022.60T/C
1022.10G
1022.61T/C
1022.11G
1022.85T/C
1022.35G
1022.53T/C
1022.03G
STRUCTURE #1
OVERTOPPING
1023.49T/C
1022.99G
1023.01T/C
1022.51G
1024.09T/C
1023.59G
1024.02T/C
1023.52G
1023.95T/C
1023.45G
MATCH EX.
1019.09
1019.17
1023.50
0.
7
%
3.8%0.7%
1.
2
%
1.2%
0.
7
%
0.8%
0.
9
%
0.
9
%
1023.27T/C
1022.77G 1023.21T/C
1022.71G
1023.49T/C
1022.99G
1023.50T/C
1023.00G 1023.52T/C
1023.02G
1023.21T/C
1022.71G
1022.54T/C
1022.04G1022.53T/C
1022.03G
1022.84T/C
1022.34G
1022.77T/C
1022.27G
1022.90T/C
1022.40G
1022.51T/C
1022.01G
1022.66T/C
1022.16G
1.
4
%
1022.09
1022.27
1.
0
%
1022.24E/W
1022.19E/W
1022.43T/C
1021.93G
1020.69
1022.95T/C
1022.45G
COCO CO
CO
CO CO
10
2
3
1
0
2
3
10
2
1
1021
102
2
1
0
2
2
1023
1023
1
0
2
2
10
2
3
1
0
2
3
102
3
10
1
9
1018
1021
1020
1022
1020
1
0
2
2
1020
1020
1022
1024
1023
1018
1020
1023
1
0
2
5
4:
1
4:
1
4:
1
4:
1
4:
1
4:
1
6:1
4.9%
1021.94±EX
1019.56±EX
1025.08±EX
1018.61±EX
1018.47
1026.03 EX.
100-YR PONDING=1020.56
100-YR PONDING=1020.46
100-YR
PONDING=1022.48
100-YR
PONDING=1022.21
ON-GRADE.
NO PONDING
1022.34T/C
1021.84G
2.0
%
2.
0
%
1.
2
%
2.
0
%
1022.21T/C
1021.71G
2.
0
%
1022
1022.50T/C
1022.00G
OVERSPILL=1020.56
100-YR PONDING=1021.70
100-YR
PONDING=1021.87
100-YR PONDING=1022.12
BIORETENTION LIMIT
ELEVATION=1018.00
BIORETENTION LIMITS
ELEVATION=1018.00
0.
8
%
0.
8
%
1.5%
1.0%
2.4%
0.9%1.7%
4.5%
1.
6
%
1.
6
%
1.
3
%
1.
3
%
1.
3
%
1.
3
%
1.
3
%
1.
3
%
EX. 1024.52±
EX. 1024.33±
1024.72E/W
1029.22HP
1023.26T/C
1022.76G
100-YR PONDING=1020.76
OVERSPILL=1020.76
BIORETENTION LIMITS
ELEVATION=1018.50
CO
CO
1022.84±EX
1022.90
1021.63±EX
1021.83
1023.05±EX
1023.16
1023.42T/C
1022.92G
1022.52±EX
1022.55
1022.51±EX
ON-GRADE. NO PONDING
1023.26
1023.26
1023.26
0.
7
%
1.7%
1.
5
%
0.1%
0.0%0.0%1.2%3.0%0.9%0.2%
0.9%
1021.00
1021.00
1021.211021.28
1
0
2
3
1
0
2
4
1
0
2
5
1
0
2
6
1
0
2
7
1018
1018
1021
10
2
2
10
2
0
1
0
2
3
1023
10
2
3
10
1
9
10
2
5
10
2
7
1
0
2
9
1025
10
2
9
10
2
2
1022
10
2
3
1
0
2
3
1022
2.
0
%
2.
0
%
0.
0
%
0.
0
%
1022
1022
1
0
2
9
TOP OF BERM=1022.06
1023.421023.42
1023.16
1023.42
1023.501023.50
1023.42
1.
0
%
1.
0
%
1.
0
%
6.
0
%
2.
0
%
0.0%
1.
5
%
1.
5
%
1.
5
%
0.0%0.0%0.0%
OVERFLOW ROUTE
ELEV=1022.37
OVERFLOW ROUTE
ELEV=1021.98
1022.69T/C
1022.19G
1022.96T/C
1022.46G
1021.98 1022.19
0.9%
5.
9
%
0
.
7
%
0.
7
%
0.8%
1.5%
1.5%
1.0
%
1
.
7
%
1.3%
7.
8
%
1.
4
%
1.
4
%
0.
7
%
1.6%
1023.42
0.
6
%
4.1%
5.
4
%
0.8%
1022
10
2
2
1023
10
3
0
103
1
10
2
9
10
2
8
102
6
1027
10
2
8
1024
1023
1022
1021
1020
10
2
3
10
2
3
0.8%
1.7%
1.5%
1.
5
%
1032.78 EX.
1.5%
4.5%4.3%
0.8%
1.
5
%
1018.00FL1018.00FL
1018.75FL
1018.00FL
4.8%
9.
7
%
1018.50FL
1018.50FL
1019.25FL
0.3%
D
100-YR PONDING=1021.74
1016.64
5.2%
CPV ELEV=1020.01
WQV ELEV=1019.25
WQV ELEV=1018.75
CPV ELEV=1019.57
100-YR PONDING =1020.56
CPV ELEV=1019.57
WQV ELEV=1018.75
MAX PONDING=1021.50 MAX PONDING=1021.50
1017.10FL
WV
H Y D
F/OF/O
F/OFO
D
D
WV
H Y D
F/O
WV
WV
WV
H Y D
FO
D
SS
D
F/OT
F/O
EX ROCK
EX CONCRETE
EX CONCRETE
EX
C
O
N
C
R
E
T
E
S
I
D
E
W
A
L
K
ST
15"
SE
B
R
I
C
K
D
R
I
V
E
(C
O
N
C
R
E
T
E
P
U
B
L
I
C
R
O
A
D
-
8
0
'
R
.
O
.
W
.
)
SE STONE RIDGE DR
(CONCRETE PUBLIC ROAD - 70' R.O.W.)
SE
W
A
C
O
P
L
A
C
E
(C
O
N
C
R
E
T
E
P
U
B
L
I
C
R
O
A
D
-
1
0
0
'
R
.
O
.
W
.
)
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/O
F/O F/O F/O F/O F/O F/O F/O
F/
O
F/
O
F/
O
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
U
/
E
U
/
E
U/E U/E U/E U/E U/E
U/
E
U/
E
U/
E
U/E U/E U/E U/E U/E U/E U/E U/E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/E
U/
E
U/
E
U/
E
U/E
U/E U/E U/E
U/E
U/E U/E U/E
U/E
U/E U/E U/E
ST 15"ST 15"ST 15"ST 18"ST 18"ST 18"ST 18"ST 42"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
D
ST 48"ST 48"ST 48"ST 48"
SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"
S
W12
"
W12
"
W
12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W 12"W 12"W12"W12"W12"W12"W12"W12"W12"W12"W12"W12"W12"W12"
W6"
W6"
W6"
W 6"
W 6"
W
6
"
D
ST
8"
ST
8"
S
T
8
"
ST 15"
ST
18
"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G 2"G 2"G 2"G 2"G 2"G 2"G 2"G 2"G 2"G 2"
G
2"
G 2"G 2"G 2"G 2"G 2"G 2"
G
G
SA
N
8"
10' PUBLIC UTILITY EASEMENT
BK.2007 PG.15339
25' PUBLIC STORM SEWER
AND OVERLAND
FLOWAGE EASEMENT
BK. 2007 PG. 15337
PRIVATE 15'
STORM SEWER
EASEMENT
BK. 2007 PG. 15329
15
'
P
R
I
V
A
T
E
W
A
T
E
R
M
A
I
N
E
A
S
E
M
E
N
T
BK
.
2
0
0
7
P
G
.
1
5
3
3
2
10' PUBLIC UTILITY EASEMENT
BK.2007 PG.15339
7.
5
'
P
U
B
L
I
C
S
T
O
R
M
SE
W
E
R
E
A
S
E
M
E
N
T
BK
.
2
0
0
7
P
G
.
1
5
3
3
8
65
'
P
R
I
V
A
T
E
O
V
E
R
L
A
N
D
FL
O
W
A
G
E
A
N
D
D
E
T
E
N
T
I
O
N
EA
S
E
M
E
N
T
BK
.
2
0
0
7
P
G
.
1
5
3
2
8
WV
D
ST
W8"W8"W8"W8"W8"
ST
42
"
ST
42
"
ST
42
"
S
D D
D
S
D
ST
42"
ST
42
"
ST
42
"
ST
42
"
ST
42
"
ST
42
"
ST
42
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST 15"
ST 15"
S
S
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
S
A
N
1
0
"
S
A
N
1
0
"
S
A
N
1
0
"
SAN10"
SA
N
10
"
HY D
WV
WV
H Y D
W
W
W
W
W
W
W
W
W
W
G
G
G
G
G
G
G
G
G
G
G
G
G
G
U/E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
ST
8"
ST
8"
ST
15"
S
T
1
5
"
D
REGIONAL DETENTION POND
100-YR HWEL = 1020.48
102
7
1028
1
0
2
6
1025
1
0
2
6
1
0
2
7
1
0
2
9
1
0
3
0
1
0
3
1
1
0
3
0
10
2
9
10
2
5
1020
1017
10
1
7
10
2
0
102
5
1
0
2
1
102
1
102
2
10
2
2
10
2
5
1023
10
2
3
1024
1
0
2
3
1025
10
2
5
10
2
5
10
2
3
1
0
2
0
1
0
1
9
1017
1
0
2
0
1
0
2
1
1
0
2
2
10
2
2
1
0
2
0
102210
2
3
1
0
2
5
10
3
1
10
3
0
10
2
9
1
0
2
8
1
0
2
7
10
2
4
10
2
3
1021
1020
101
9
101
8
10
1
7
1017
101
8
10
1
9
1019
1020
1021
10
2
2
1023
1022
10
2
3
10
2
3
10
2
5
1
0
2
5
1
0
2
5
102
5
1
0
2
3
1
0
2
2
1
0
2
1
10
2
1
102
0
10
2
3
10
2
3
1022
1
0
2
2
1020
1017
10
2
6
1
0
2
6
10
2
5
10
2
4
10
2
3
10
2
2
10
2
1
1
0
2
0
10
1
9
10
1
8
10
1
7
1
0
1
8
1
0
1
9
10
2
2
10
2
4
1
0
2
3
10
2
3
102
4
1
0
2
5
1
0
2
3
10
2
3
1022
1022
10
2
3
10
2
2
10
3
1
100 YEAR PONDING
ELEV. = 1020.48
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
#
IS
S
U
E
D
A
T
E
NB
I
#
:
-
-
-
-
-
-
-
-
DB
S
#
:
2
2
-
3
-
4
4
2
DR
A
W
N
B
Y
:
G
S
A
CH
E
C
K
E
D
B
Y
:
S
V
S
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
#
IS
S
U
E
D
A
T
E
ST
I
V
E
R
S
GE
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
-
A
R
C
H
I
T
E
C
T
14
3
5
o
h
i
o
s
t
r
e
e
t
/
p
.
o
.
b
o
x
1
3
1
5
/
d
e
s
m
o
i
n
e
s
,
i
a
5
0
3
0
5
-
1
3
1
5
ph
o
n
e
:
(
5
1
5
)
2
4
3
-
0
1
5
6
/
f
a
x
:
(
5
1
5
)
2
4
3
-
0
1
6
5
NE
U
M
A
N
N
B
R
O
T
H
E
R
S
,
I
N
C
.
-
D
E
S
I
G
N
B
U
I
L
D
S
O
L
U
T
I
O
N
S
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Copyright DesignBuild Solutions, LC. Protected under Architectural Works Copyright Protection Act of 1990.
FIELD BULLETINS
ASSOCIATED WITH
THIS SHEET:
01
/
1
1
/
2
0
2
3
1S
T
C
I
T
Y
S
U
B
M
I
T
T
A
L
04
/
0
6
/
2
0
2
3
2N
D
C
I
T
Y
S
U
B
M
I
T
T
A
L
06
/
1
6
/
2
0
2
3
3R
D
C
I
T
Y
S
U
B
M
I
T
T
A
L
08
/
2
8
/
2
0
2
3
4T
H
C
I
T
Y
S
U
B
M
I
T
T
A
L
09
/
1
3
/
2
0
2
3
5T
H
C
I
T
Y
S
U
B
M
I
T
T
A
L
12
/
1
9
/
2
0
2
2
5
:
0
0
:
1
3
P
M
FO
R
D
P
R
O
C
E
N
T
E
R
13
5
0
S
E
S
t
o
n
e
R
i
d
g
e
D
r
i
v
e
,
W
a
u
k
e
e
,
I
o
w
a
5
0
2
6
3
GRAPHIC SCALE
030 15 30 60
L:
\
L
A
N
D
P
R
O
J
E
C
T
S
2
0
2
2
\
2
2
0
3
2
8
\
D
W
G
\
C
3
G
R
A
D
I
N
G
.
D
W
G
9/
1
3
/
2
0
2
3
1
:
5
7
:
0
2
P
M
GRADING LEGEND:
EXISTING CONTOUR
PROPOSED CONTOUR
FINISHED GROUND ELEVATION
TOP OF CURB ELEVATION
GUTTER ELEVATION
TOP OF WALL ELEVATION
BOTTOM OF WALL ELEVATION
EDGE OF WALK ELEVATION
TOP OF STAIR ELEVATION
BOTTOM OF STAIR ELEVATION
NOTE: WALL ELEVATIONS SHOWN ON PLAN ARE FINISHED
GROUND GRADES AT THE TOP AND BOTTOM OF THE WALL.
150.50E/W
150.50B/W
150.50T/W
150.50G
150.50T/C
150.50
150
150
150.50T/S
150.50B/S
GENERAL NOTES:
1.CONTRACTOR TO COORDINATE WITH ARCHITECTURAL PLANS
FOR BUILDING OVERHEAD AND MAN DOOR ELEVATION DETAILS.
ALL BUILDING STOOPS SHALL HAVE A MINIMUM 1.0% CROSS
SLOPE AND A MAX 2% CROSS SLOPE.
2.CONTRACTOR TO VERIFY AND COORDINATE EXTERIOR
PAVEMENT ELEVATIONS ADJACENT TO STOOP AND DOOR
LOCATIONS TO PROVIDE A MINIMUM 1.0% SLOPE AND A MAX 5%
SLOPE AWAY FROM BUILDING AND BUILDING STOOPS.
3.ALL LIGHT DUTY AND HEAVY DUTY PAVEMENT AREAS SHALL
HAVE A MINIMUM 1.0% SLOPE TO PROVIDE POSITIVE DRAINAGE.
4.SIDEWALKS SHALL HAVE A MINIMUM 1.0% CROSS SLOPE AND A
MAX 2% CROSS SLOPE AT ANY LOCATION.
5.THE GENERAL CONTRACTOR AND THEIR SURVEYOR SHALL BE
RESPONSIBLE FOR CREATING THE STAKING MODEL.
CONTRACTOR TO VERIFY ALL GRADING ELEVATIONS AND
CONTACT THE OWNER/ENGINEER, PRIOR TO CONSTRUCTION, IF
THERE ARE ANY DISCREPANCIES OR CONFLICTS BETWEEN THE
PLANS AND TYPICAL CONSTRUCTION STANDARDS AND
TOLERANCES.
6.ANY AS-BUILT PAVEMENTS AREAS THAT ARE IDENTIFIED TO
HAVE LOW SPOTS OR PONDING SHALL BE REMOVED AND
REPLACED, AT CONTRACTOR'S EXPENSE, AS NEEDED TO
PROVIDE POSITIVE DRAINAGE.
7.CONTRACTOR SHALL ADJUST EXISTING UTILITY STRUCTURES
RIMS TO GRADE.
8.CONTRACTOR TO COORDINATE WITH UTILITY PROVIDERS FOR
ANY RELOCATION OR LOWERING OF EXISTING UTILITIES TO
ACCOMMODATE GRADING AND NEW UTILITIES. ANY REMOVAL
AND REPLACEMENT OF SAID UTILITIES SHALL BE INCIDENTAL.
BUILDING DOOR ELEVATIONS:
1.THE ELEVATIONS SHOWN AT THE BUILDING DOORS AND
BUILDING WALLS ON THE GRADING PLAN ARE FOR
COORDINATION ONLY. BUILDING ARCHITECTURAL/STRUCTURAL
PLANS AND DETAILS SHALL GOVERN FOR BUILDING DOOR
ELEVATIONS, STOOP SLOPES AND EXPOSED WALLS OR
FOOTINGS.
2.CONTRACTOR TO COORDINATE AND VERIFY ALL BUILDING AND
DOOR ELEVATIONS WITH EXTERIOR IMPROVEMENTS TO
MAINTAIN POSITIVE DRAINAGE AWAY FROM BUILDING PRIOR TO
CONSTRUCTION. IF THERE IS A DISCREPANCY, CONTRACTOR TO
CONTACT OWNER/ENGINEER FOR DIRECTION PRIOR TO
CONSTRUCTION AND/OR INSTALLATION.
ADA RAMP & LANDING NOTES:
1.RAMPS ON SIDEWALKS THAT EXCEED 5% RUNNING SLOPE
MUST HAVE A MINIMUM OF 5'X5' LANDING AT THE TOP AND
BOTTOM OF THE RAMP. THE LANDING SHALL NOT EXCEED 2%
SLOPE IN ANY DIRECTION.
2.NOT ALL RAMPS AND LANDINGS ARE CALLED OUT ON PLANS.
ANYWHERE A WALK EXCEEDS 5% SLOPE, AS SHOWN ON THE
GRADING PLAN, SHALL BE CONSIDERED AN ADA RAMP AND
THEREFORE MUST HAVE LANDINGS.
TOPSOIL NOTES:
1.STRIP AND STOCKPILE THE TOP 8" OF SOIL ON ALL DISTURBED
AREAS.
2.RESPREAD TOPSOIL TO A MINIMUM DEPTH OF 8" ON ALL GREEN
(NON PAVED) AREAS. IMPORT TOPSOIL AS NECESSARY TO
ACHIEVE A MINIMUM DEPTH OF 8".
3.TOPSOIL SHALL BE FREE OF ALL ROCK AND DEBRIS LARGER
THAN 3/4" IN SIZE.
4.TOPSOIL IS DEFINED AS: FERTILE, FRIABLE LOAM, CAPABLE OF
SUSTAINING VIGOROUS PLANT GROWTH, FROM WELL DRAINED
SITE FREE FROM FLOODING, NOT IN FROZEN OR MUDDY
CONDITIONS; REASONABLE FREE FROM SUBSOIL, CLAY LUMPS,
ROOTS, GRASS, WEEDS, STONES LARGER THAN 3/4 INCH IN
DIAMETER, AND FOREIGN MATTER; ACIDITY RANGE (PH) OF 5.5
TO 7.5; CONTAINING MINIMUM 4 PERCENT AND MAXIMUM 20
PERCENT ORGANIC MATTER.
5.CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING ALL
TOPSOIL REQUIREMENTS OF NPDES GENERAL PERMIT NO. 2
ARE MET.
C3.1
GRADING
PLAN
OWNER MAINTENANCE NOTES:
1.THE OWNER SHALL BE RESPONSIBLE FOR MAINTAINING THE
DETENTION BASIN TO ASSURE THE EFFECTIVENESS OF STORM
WATER MANAGEMENT.
2.CONDUCT QUARTERLY INSPECTIONS FOR ANY DEFECTS,
OBSTRUCTIONS OR CHANGES FROM ORIGINAL DESIGN.
3.REMOVE ALL TRASH, LITTER, DEBRIS OR OBSTRUCTIONS FROM
THE BASIN AND ANY INLETS & OUTLETS.
4.INSPECT AND DETERMINE DEPTH OF BASIN ON AN ANNUAL
BASIS.
5.REMOVE ANY ACCUMULATED SEDIMENT FROM THE OUTLET
STRUCTURE ANNUALLY. REMOVE ANY SEDIMENT
ACCUMULATED IN THE BASIN WHEN IT HAS REACHED A DEPTH
OF 25% OR MORE OF THE ORIGINAL DESIGN DEPTH.
6.ALL MAINTENANCE, RESTORATION AND REPAIRS SHALL
COMPLY WITH THE ORIGINAL DESIGN.
5,670 SF
FUTURE
DISPLAY
ROOM
PROP. BUILDING
PROP. 34,150 SQ. FT.
FF=1023.50'
HT.=23.00
80 LF- 8" WATER SERVICE
F.D.C
(REF. ARCH)
WV
CONNECT TO
EX. 8" WATER WITH MJ TEE
(CONTRACTOR TO VERIFY PRIOR
TO CONSTRUCTION)
CONNECT TO BUILDING
SERVICES.
(REF. PLUMBING PLANS)
90° BEND
33 LF- 8" WATERMAIN
R150'A/
C
AC UNITS ON
CONC. PAD
(REF. ELEC.)
FF=1023.50
(PER 2018 DESIGN
REF. PROJECT #180108)
57 LF- 2.5"
WATER SERVICE
CONNECT TO BUILDING
SERVICES.
(REF. PLUMBING PLANS)
CONNECT TO
EX. WATER WITH TAPPING
SLEEVE AND VALVE
(CONTRACTOR TO VERIFY PRIOR
TO CONSTRUCTION)
HYD
HYDRANT
ASSEMBLY
6"x2.5" TEE
13
0
L
F
-
6"
W
A
T
E
R
M
A
I
N
29
L
F
-
6"
WA
T
E
R
M
A
I
N
REMOVE EX. BLOWOFF
HYDRANT & EXTEND SERVICE
(CONTRACTOR TO VERIFY PRIOR
TO CONSTRUCTION)
HYD HYDRANT
ASSEMBLY
46 LF- 6"
WATERMAIN
CONNECT TO BUILDING
ROOF DRAIN SYSTEM.
(REF. PLUMB. PLANS)
H Y D
13
8
L
F
-
6"
W
A
T
E
R
M
A
I
N
HYDRANT
ASSEMBLY
TRANSFORMER
ON CONC. PAD
(REF. ELEC.)
STRUCTURE #1
72" SW-502 INTAKE
W/ FLAT GRATE
& 6' SUMP (1013.19)
RIM=1022.34
FL(N)=1019.19
STRUCTURE #3
72" SW-502 INTAKE
W/ FLAT GRATE
& 6' SUMP (1012.57)
RIM=1021.61
FL(S)=1018.67
FL(W)=1018.67
FL(NW)=1018.57
PI
P
E
#
1
10
4
L
F
1
5
"
R
C
P
@
S
=
0
.
5
0
%
D
STRUCTURE #10A
MODIFIED 48" SW-401 MANHOLE
(REF. DETAIL 16/C6.1)
RIM=1022.00
SUMP FL =1011.75
FL(6" N-12)=1014.20
FL(SW)=1017.77
FL(NE)=1013.75
PIPE #3
76LF 15" RCP @ S=0.50%
STRUCTURE #9
72" SW-502 INTAKE
W/ STANDARD GRATE
& 6' SUMP (1012.37)
T/C=1021.64
FL(S)=1018.37
FL(W)=1018.37
FL(E)=1018.37
STRUCTURE #8
15" FES
FL(E)=1018.00
PIPE #8
53LF 15" RCP @ S=0.70%
STRUCTURE #6
72" SW-502 INTAKE
W/ STANDARD GRATE
& 6' SUMP (1013.39)
T/C=1022.50
FL(N)=1019.39
FL(NE)=1019.49
STRUCTURE #12
72" SW-502 INTAKE
W/ STANDARD GRATE
& 6' SUMP (1012.61)
T/C=1023.09
FL(W)=1018.61
FL(E)=1018.66
STRUCTURE #12A
18" FES
FL(E)=1018.50
PIPE #12
35LF 18" RCP @ S=0.30%
STRUCTURE #14
60" SW-502 INTAKE
W/ STANDARD GRATE
& 6' SUMP (1013.61)
T/C=1022.44
FL(W)=1018.61
FL(E)=1018.61
STRUCTURE #14A
18" FES
FL(E)=1018.50
PIPE #14
36LF 18" RCP @ S=0.30%
STRUCTURE #15
18" FES
FL(S)=1019.00
D
STRUCTURE #15A
MODIFIED 48" SW-401 MANHOLE
RIM=1023.45
SUMP FL=1015.24
FL(E)=1017.24
FL(N)=1017.34
(REF. DETAIL 19/C6.1)
PIPE #15
30LF 18" RCP @ S=5.49%
STRUCTURE #15B
18" FES
FL(W)=1017.10
47LF 18" RCP @ S=0.30%
PIP
E
#
6
92
L
F
1
2
"
R
C
P
@
S
=
0
.
5
0
%
**CRITICAL CROSSING**
15" STORM (BOT.)=1016.38
6" WATER (TOP)=1013.04
BEND WATERMAIN UNDER STORM
(18" MIN. SEPARATION)
PIPE #11
321LF 15" N-12 @ S=0.30%
(DURASLOT DRAIN, RIM TO MATCH PROPOSED GRADES)
STRUCTURE #11
72" SW-502 INTAKE
W/ FLAT GRATE
& 6' SUMP (1013.62)
RIM=1022.55
FL(W)=1019.62
CO
STRUCTURE #5
CLEANOUT
RIM=1023.36
FL(SW)=1019.28
PIPE #
5
42LF 1
2
"
N
-
1
2
@
S
=
0
.
5
0
%
(ROO
F
D
R
A
I
N
C
O
L
L
E
C
T
I
O
N
L
I
N
E
)
CO
STRUCTURE #2
CLEANOUT
RIM=1023.29
FL(E)=1020.25
CO
STRUCURE #2A
CLEANOUT
RIM=1022.89
FL(W)=1019.10
FL(E)=1019.10
PIPE #2
115LF 12" N-12 @ S=1.00%
(ROOF DRAIN COLLECTION LINE)
43LF 12" N-12 @ S=1.00%
(ROOF DRAIN COLLECTION LINE)
40LF 18" RCP @ S=1.87%
CO
STRUCTURE #7
CLEANOUT
RIM=1023.45
FL(NW)=1018.97
PIPE #7
31LF 12" N-12 @ S=0.13%
(ROOF DRAIN COLLECTION LINE)
CONNECT TO BUILDING
ROOF DRAIN SYSTEM.
(REF. PLUMB. PLANS)
**CRITICAL CROSSING**
EX. SANI SWR UNDER STORM
24" STORM (BOT.)=1011.78
EX. 8" SAN (TOP)=1004.18
NEW FL(SW 24")=1013.00
CORE DRILL & CONNECT
TO EX. MANHOLE
ELEC. CONDUIT
SANI SWR MH #01
48" SW-301
RIM=1022.25
INV(SW,SE)=1008.10
INV(N)=1008.00
65 LF-
4" SAN
I
S
W
R
@ S=
2.0%
M
I
N
CONNECT TO EX. SERVICE STUB
W/ WYE & RISER
(CONTRACTOR TO VERIFY INVERT
PRIOR TO CONSTRUCTION)
CO
SANI SWR CLEANOUT
RIM=1023.45
INV=1016.00
(REF. PLUMB. FOR
CONTINUATION)
CONNECT TO BUILDING
SERVICES.
(REF. PLUMBING PLANS)
**CRITICAL CROSSING CONFLICT**
EX. GAS OVER STORM
EX. 2" GAS (BOT.)=1015.03
24" STORM (TOP)=1014.19
(3' DEPTH ASSUMED FOR EX. GAS.
VERIFY EX. 2" GAS DEPTH & AVOID CONFLICT.)
**CRITICAL CROSSING CONFLICT**
EX. U/E OVER STORM
EX. U/E (BOT.)=1015.80
24" STORM (TOP)=1014.43
(3' DEPTH ASSUMED FOR EX. U/E.
VERIFY EX. U/E DEPTH & AVOID CONFLICT.)
**CRITICAL CROSSING CONFLICT**
EX. U/E OVER STORM
EX. U/E (BOT.)=1016.01
24" STORM (TOP)=1014.54
(3' DEPTH ASSUMED FOR EX. U/E.
VERIFY EX. U/E DEPTH & AVOID CONFLICT.)
40
L
F
-
8"
SA
N
I
S
W
R
@
S
=
2.
0
%
M
I
N
STRUCTURE #9A
15" FES
FL(W)=1018.00
PIPE #09
30LF 18" RCP @ S=1.22%
SANI SWR
BUILDING SAND/OIL
SEPARATOR
(REF. MEP PLANS)
INV =1019.30
(REF. MEP PLANS FOR
CONTINUATION)
SANI SWR CLEANOUT
RIM=1023.00
INV =1018.50
(REF. MEP PLANS FOR
CONTINUATION)
CO
SANI SWR CLEANOUT
RIM=1022.20
INV=1012.00
CO
10
0
L
F
-
6"
SA
N
I
S
W
R
@
S
=
2.
0
%
M
I
N
5
5
L
F
-
6
"
S
A
N
I
S
W
R
@
S
=
2
.
0
%
M
I
N
**CRITICAL CROSSING**
EX. SANI SWR UNDER STORM
12" STORM (BOT.)=1018.87
6" SANI (TOP)=1012.14
GAS SERVICE.
(COORDINATE WITH
UTILITY PROVIDER)
S
STRUCTURE #4
60" SW-502 INTAKE
W/ STANDARD GRATE
& 6' SUMP (1012.09)
T/C=1022.10
FL(SE)=1018.19
FL(N)=1018.09
STRUCTURE #4A
15" FES
FL(S)=1018.00
PIPE #4
17LF 15" RCP @ S=0.50%
STRUCTURE #13
60" SW-502 INTAKE
W/ STANDARD GRATE
& 5' SUMP (1013.89)
T/C=1022.34
FL(W)=1018.89
PIPE #13
95LF 12" RCP @ S=0.30%
COCO CO
CO
STORM CLEANOUT
RIM=1019.15
FL=1015.15
STORM CLEANOUT
RIM=1019.65
FL=1015.45
85 LF -6" SUBDRAIN @ S=0.25% MIN.
STORM CLEANOUT
RIM=1021.35
FL=1014.95
233 LF -6" SUBDRAIN
@ S=0.25% MIN.
STORM CLEANOUT
RIM=1019.55
FL=1014.30
69 LF -6" N-12
@ S=0.25% MIN.
13 LF -6" N-12
@ S=0.25% MIN.
**CRITICAL CROSSING**
12" STORM (BOT.)=1018.77
2.5" WATER (TOP)=1017.27
BEND WATERMAIN UNDER STORM
(18" MIN. SEPARATION)
STRUCTURE #10
24" FES
FL(NE)=1018.75
PIPE #10
11LF 24" RCP @ S=8.96%
GAS SERVICE
CONNECTION.
(COORDINATE WITH
UTILITY PROVIDER)
65 LF-
4" SAN
I
S
W
R
@ S=
2.0%
M
I
N
CO
SANI SWR
CLEANOUT
RIM=1022.30
INV=1014.70
5
5
L
F
-
6
"
S
A
N
I
S
W
R
@
S
=
2
.
0
%
M
I
N
CO
SANI SWR CLEANOUT
RIM=1022.24
INV=1010.90
**CRITICAL CROSSING**
12" STORM(BOT.)=1018.28
6" STORM(TOP)=1015.59
CRITICAL CROSSING
12" STORM(BOT.)=1018.28
6" STORM(TOP)=1015.58
**CRITICAL CROSSING**
36" STORM(BOT.)=1018.18
8" WATER(TOP)=1016.68
WATER SERVICE CURB
STOP
CO
CO
STORM CLEANOUT
RIM=1019.75
FL=1017.74
14
0
L
F
-
6"
S
U
B
D
R
A
I
N
@
S
=
0.
2
5
%
M
I
N
.
STORM CLEANOUT
RIM=1021.00
FL=1017.39
18 L.F. OF 6" N-12 PIPE @ 0.25%
**CRITICAL CROSSING**
15" N-12 (BOT)=1019.34
EX. 36" STORM (TOP)=1018.96
(CONTRACTOR TO INSTALL EXPANSION
MATERIAL BETWEEN PIPES
STRUCTURE #16
RAIN GUARDIAN - TURRET
RIM=1021.00
FL=1020.25
STRUCTURE #17
RAIN GUARDIAN - TURRET
RIM=1021.00
FL=1020.25
**CRITICAL CROSSING**
6" STORM (BOT.)=1014.54
6" WATER (TOP)=1013.04
BEND WATERMAIN UNDER STORM
(18" MIN. SEPARATION)
**CRITICAL CROSSING**
ElEC. CONDUIT (BOT.)=1020.58
6" WATER (TOP)=1018.08
**CRITICAL CROSSING**
8" SANI SWR UNDER
6" SUBDRAIN
(CONTRACTOR TO VERIFY EX. SANI
SWR INVERT TIE IN PRIOR TO
CONSTRUCTION TO AVOID CONFLICT)
**CRITICAL CROSSING**
6" STORM (BOT.)=1014.39
6" WATER (TOP)=1012.50
WATERMAIN UNDER STORM
(18" MIN. SEPARATION)
**CRITICAL CROSSING**
BEND GAS UNDER STORM
PIPE IF NECESSARY
**CRITICAL CROSSING**
BEND GAS UNDER STORM
PIPE IF NECESSARY
**CRITICAL CROSSING**
SANITARY SEWER
UNDER GAS LINE
8" DIA DOWNSPOUT
CONNECTION LINE
@ 2.0% MIN, TYP.
REF. DETAIL 6, C601
8" DIA DOWNSPOUT
CONNECTION LINE
@ 2.0% MIN, TYP.
REF. DETAIL 6, C601
(REF. DETAIL 3, C6.2)
D
PI
P
E
#
7
9
2
L
F
1
2
"
R
C
P
@
S
=
0
.
5
0
%
STRUCTURE #07A
72" SW-401 MANHOLE
& 6' SUMP (1012.83)
RIM=1023.08
FL(S)=1018.93
FL(SE)=1018.93
FL(N)=1018.83
WV
H Y D
F/OF/O
F/OFO
D
EX STORM MH
RIM=1025.75
FL(W)=1020.90
FL(NE)=1020.70
D
EX STORM MH
RIM=1024.69
FL(SW)=1020.34
FL(E)=1020.14
WV
H Y D
F/O
WV
WV
WV
H Y D
FO
D
EX 48" RECTANGULAR STORM MH
RIM=1017.70
FL(SW 15")=1013.00 (DEMO)
FL(W 18")=1012.80
FL(S 36")=1011.80
FL(E 42")=1011.70
S
EX SAN MH
RIM=1021.45
INV(E 8")=1004.33
INV(W 8")=1004.30
S
EX SAN MH
RIM=1022.79
INV(W 8")=1005.04
INV(E 8")=1004.99
INV(S 8")=1004.96
D
EX STORM MH
RIM=1022.39
FL(S 15")=1018.49(DEMO)
FL(W 15")=1018.39
FL(E 18")=1018.34
F/OT
EX INTAKE
T/C=1025.69
GUT=1024.97
EX INTAKE
T/C=1022.22
GUT=1021.72
F/O
EX ROCK
EX CONCRETE
EX CONCRETE
EX
C
O
N
C
R
E
T
E
S
I
D
E
W
A
L
K
ST
15"
SE
B
R
I
C
K
D
R
I
V
E
(C
O
N
C
R
E
T
E
P
U
B
L
I
C
R
O
A
D
-
8
0
'
R
.
O
.
W
.
)
SE STONE RIDGE DR
(CONCRETE PUBLIC ROAD - 70' R.O.W.)
SE
W
A
C
O
P
L
A
C
E
(C
O
N
C
R
E
T
E
P
U
B
L
I
C
R
O
A
D
-
1
0
0
'
R
.
O
.
W
.
)
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
EX LOCATION PER
AUREON & UPN MAPS
F/
O
F/
O
F/
O
F/
O
F/
O
F/
O
EX LOCATION PER
CENTURYLINK MAP
F/
O
F/
O
F/
O
F/O
F/O F/O F/O F/O F/O F/O F/O
F/
O
F/
O
F/
O
EX LOCATION PER
CENTURYLINK MAP
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
EX LOCATION PER
MEDIACOM MAP
U
/
E
U
/
E
U/E U/E U/E U/E U/E
U/
E
U/
E
U/
E
U/E U/E U/E U/E U/E U/E U/E U/E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
EX LOCATION PER
MIDAMERICAN MAP
EX LOCATION PER
MIDAMERICAN MAP
U/
E
U/
E
U/E
U/
E
U/
E
U/
E
U/E
U/E U/E U/E
U/E
U/E U/E U/E
U/E
U/E U/E U/E
ST 15"ST 15"ST 15"ST 18"ST 18"ST 18"ST 18"ST 42"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
D
ST 48"ST 48"ST 48"ST 48"
SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"
SEX LOCATION PER
CITY MAP & AERIAL
W12
"
W12
"
W
12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
EX WATER LINE LOCATION
PER CITY OF WAUKEE GIS
W 12"W 12"W12"W12"W12"W12"W12"W12"W12"W12"W12"W12"W12"W12"
W6"
EX WATER LOCATIONS PER
CITY OF WAUKEE GIS
W6"
W6"
W 6"
W 6"
W
6
"
D
ST
8"
ST
8"
S
T
8
"
ST 15"
ST
18
"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G 2"G 2"G 2"G 2"G 2"G 2"G 2"G 2"G 2"G 2"
G
2"
G 2"G 2"G 2"G 2"G 2"G 2"
G
G
SA
N
8"
EX SERVICE
STUB PER CITY GIS
10' PUBLIC UTILITY EASEMENT
BK.2007 PG.15339
25' PUBLIC STORM SEWER
AND OVERLAND
FLOWAGE EASEMENT
BK. 2007 PG. 15337
PRIVATE 15'
STORM SEWER
EASEMENT
BK. 2007 PG. 15329
15
'
P
R
I
V
A
T
E
W
A
T
E
R
M
A
I
N
E
A
S
E
M
E
N
T
BK
.
2
0
0
7
P
G
.
1
5
3
3
2
10' PUBLIC UTILITY EASEMENT
BK.2007 PG.15339
7.
5
'
P
U
B
L
I
C
S
T
O
R
M
SE
W
E
R
E
A
S
E
M
E
N
T
BK
.
2
0
0
7
P
G
.
1
5
3
3
8
65
'
P
R
I
V
A
T
E
O
V
E
R
L
A
N
D
FL
O
W
A
G
E
A
N
D
D
E
T
E
N
T
I
O
N
EA
S
E
M
E
N
T
BK
.
2
0
0
7
P
G
.
1
5
3
2
8
WV
EX 48" FES
FL=1017.06
D
EX STORM MH
RIM=1032.11
FL(SW 24")=1021.71
FL(S 48")=1018.61
FL(E 48")=1018.46
ST
W8"W8"W8"W8"W8"
ST
42
"
ST
42
"
ST
42
"
EX. SW-505 INTAKE
T/C=1021.75
GUT=1021.25
FL(S)=1017.32
100YR HWEL=1021.77
(PER 2018 BE DESIGN
REF. PROJECT #180108)
EX. 15" FES
FL=1016.60
(PER 2018 BE DESIGN
REF. PROJECT #180108)
EX. SW-505 INTAKE
T/C=1021.10
GUT=1020.60
FL(S)=1017.22
100YR HWEL=1021.13
(PER 2018 BE DESIGN
REF. PROJECT #180108)
EX. 15" FES
FL=1016.60
(PER 2018 BE DESIGN
REF. PROJECT #180108)
EX STORM MH
RIM=1021.96
FL(S,N)=1016.56
S
EX SAN MH
RIM=1021.20
INV(S)=1001.38
INV(W)=1001.20
INV(S)=1001.04
EX INTAKE
T/C=1017.01
FL(N,S)=1011.02
EX STORM MH
RIM=1017.21
FL(S)=1011.26
FL(W)=1011.03
FL(N)=1011.03
D D
D
S
D
ST
42"
ST
42
"
ST
42
"
ST
42
"
ST
42
"
ST
42
"
ST
42
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST 15"
ST 15"
EX STORM MH
RIM=1020.92
EX STORM MH
RIM=1022.17
FL(E)=1016.47
FL(S)=1014.85
FL(N)=1014.97
EX INTAKE
T/C=1021.68
FL(E)=1017.18
FL(W)=1017.15
EX INTAKE
T/C=1021.42
FL(W)=1016.97
EX STORM MH
RIM=1024.81
FL(S)=1016.70
FL(N)=1016.41
EX INTAKE
T/C=1024.82
FL(E,W)=20.89
EX INTAKE
T/C=1024.77
FL(E)=10021.37
EX INTAKE
T/C=1024.77
EX INTAKE
T/C=1024.77
EX 15" FES
FL=1021.96
EX STORM MH
RIM=1024.89
FL(N,S)=1019.16
S
S
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
S
A
N
1
0
"
S
A
N
1
0
"
S
A
N
1
0
"
SAN10"
SA
N
10
"
HY D
WV
WV
H Y D
W
W
W
W
W
W
W
W
W
W
G
G
G
G
G
G
G
G
G
G
G
G
G
G
U/E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
EX INTAKE
T/C=1017.02
EX INTAKE
T/C=1017.00
FL(S)=1010.82
EX STORM MH
RIM=1017.76
ST
8"
ST
8"
ST
15"
S
T
1
5
"
D
EX. SW-502
T/C=1020.75
GUT=1020.25
FL(SW, SE)=1014.21
FL(N)=1014.11
100YR HWEL=1020.61
EX. SW-401 W/DOME INTAKE
GRATE
RIM=1023.40
FL(SE)=1015.35
FL(NW)=1015.25
EX. INTAKE
T/C=1022.90
GUT=1022.40
FL(S)=1016.42
FL(N)=1016.32
100YR HWEL=1022.68
EX. 8" DRAIN BASIN
W/DOME GRATE
RIM=1022.70
FL(N)=1017.32
EX. 8" DRAIN BASIN
W/DOME GRATE
RIM=1022.70
FL(N)=1018.18
REGIONAL DETENTION POND
100-YR HWEL = 1020.48
EX 24" FES
FL=1016.84
EX 18" FES
FL=1016.93
UTILITY NOTES:
1.ALL PROPOSED UTILTIES SHALL BE PRIVATE, UNLESS NOTED OTHERWISE.
2.ALL WATER LINES SHALL HAVE A MINIMUM OF 5.5' OF COVER UNLESS
NOTED OTHERWISE.
3.FIRE HYDRANT ASSEMBLY SHALL INCLUDE THE TEE, BRANCH, VALVE AND
HYDRANT.
4.PIPE LENGTHS CALLED OUT ON PLANS INCLUDE FLARED END SECTION,
WHERE APPLICABLE.
5.STORM SEWER CALLED OUT AS RCP MUST BE CLASS III RCP.
6.STORM SEWER CALLED OUT AS N-12 MAY BE EITHER N-12 OR CLASS III
RCP.
7.FOR RCP PIPE, ASSOCIATED F.E.S. MUST BE RCP. FOR N-12 PIPE,
ASSOCIATED F.E.S. SHALL BE CMP.
8.ALL NYLOPLAST BASINS SHALL HAVE CASTINGS SECURELY FASTENED TO
THE BASIN BODY, AND ALL GRATES/LIDS SHALL BE BOLTED DOWN TO THE
CASTINGS.
9.TRANSFORMER PAD IS SHOWN FOR REFERENCE ONLY AND MAY NOT BE
DRAWN TO ACTUAL SIZE. PAD SHALL CONFORM TO ALL UTILITY COMPANY
DESIGN STANDARDS AND SPECIFICATIONS.
10.ALL SW-505 & SW-501 STRUCTURES TO USE SW-603 TYPE R CASTINGS.
11.ALL ROOF DRAINS TO TIE INTO PROPOSED STORM WATER NETWORK AND
WILL NOT DAYLIGHT.
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
#
IS
S
U
E
D
A
T
E
NB
I
#
:
-
-
-
-
-
-
-
-
DB
S
#
:
2
2
-
3
-
4
4
2
DR
A
W
N
B
Y
:
G
S
A
CH
E
C
K
E
D
B
Y
:
S
V
S
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
#
IS
S
U
E
D
A
T
E
ST
I
V
E
R
S
GE
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
-
A
R
C
H
I
T
E
C
T
14
3
5
o
h
i
o
s
t
r
e
e
t
/
p
.
o
.
b
o
x
1
3
1
5
/
d
e
s
m
o
i
n
e
s
,
i
a
5
0
3
0
5
-
1
3
1
5
ph
o
n
e
:
(
5
1
5
)
2
4
3
-
0
1
5
6
/
f
a
x
:
(
5
1
5
)
2
4
3
-
0
1
6
5
NE
U
M
A
N
N
B
R
O
T
H
E
R
S
,
I
N
C
.
-
D
E
S
I
G
N
B
U
I
L
D
S
O
L
U
T
I
O
N
S
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Copyright DesignBuild Solutions, LC. Protected under Architectural Works Copyright Protection Act of 1990.
FIELD BULLETINS
ASSOCIATED WITH
THIS SHEET:
01
/
1
1
/
2
0
2
3
1S
T
C
I
T
Y
S
U
B
M
I
T
T
A
L
04
/
0
6
/
2
0
2
3
2N
D
C
I
T
Y
S
U
B
M
I
T
T
A
L
06
/
1
6
/
2
0
2
3
3R
D
C
I
T
Y
S
U
B
M
I
T
T
A
L
08
/
2
8
/
2
0
2
3
4T
H
C
I
T
Y
S
U
B
M
I
T
T
A
L
09
/
1
3
/
2
0
2
3
5T
H
C
I
T
Y
S
U
B
M
I
T
T
A
L
12
/
1
9
/
2
0
2
2
5
:
0
0
:
1
3
P
M
FO
R
D
P
R
O
C
E
N
T
E
R
13
5
0
S
E
S
t
o
n
e
R
i
d
g
e
D
r
i
v
e
,
W
a
u
k
e
e
,
I
o
w
a
5
0
2
6
3
GRAPHIC SCALE
030 15 30 60
L:
\
L
A
N
D
P
R
O
J
E
C
T
S
2
0
2
2
\
2
2
0
3
2
8
\
D
W
G
\
C
4
U
T
I
L
I
T
Y
.
D
W
G
9/
1
3
/
2
0
2
3
4
:
2
6
:
4
8
P
M
C4.1
UTILITY PLAN
WV
H Y D
F/OF/O
F/O
FO
D
D
WV
H Y D
F/O
WV
WV
WV
H Y D
FO
D
SS
D
F/OT
F/O
EX ROCK
EX CONCRETE
EX CONCRETE
EX
C
O
N
C
R
E
T
E
S
I
D
E
W
A
L
K
ST
15"
SE
B
R
I
C
K
D
R
I
V
E
(C
O
N
C
R
E
T
E
P
U
B
L
I
C
R
O
A
D
-
8
0
'
R
.
O
.
W
.
)
SE STONE RIDGE DR
(CONCRETE PUBLIC ROAD - 70' R.O.W.)
SE
W
A
C
O
P
L
A
C
E
(C
O
N
C
R
E
T
E
P
U
B
L
I
C
R
O
A
D
-
1
0
0
'
R
.
O
.
W
.
)
F/
O
F/
O
F/
O
F/O
F/O F/O F/O F/O F/O F/O F/O
F/
O
F/
O
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
U
/
E
U
/
E
U/E U/E U/E U/E U/E
U/
E
U/
E
U/
E
U/E U/E U/E U/E U/E U/E U/E U/E
U/
E
U/
E
U/E
U/
E
U/
E
U/E
U/E U/E U/E
U/E
U/E U/E U/E
U/E
U/E U/E U/E
ST 15"ST 15"ST 15"ST 18"ST 18"ST 18"ST 18"ST 42"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
D
ST 48"ST 48"ST 48"ST 48"
SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"
S
W12
"
W12
"
W
12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12"W12"W12"W12"W12"W12"W12"W12"W12"W12"W12"W12"W12"W12"
W6"
W6"
W
6"
W 6"
W 6"
W
6
"
D
ST
8"
ST
8"
S
T
8
"
ST 15"
ST
18
"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G
2"
G 2"G 2"G 2"G 2"G 2"G 2"G 2"G 2"G 2"G 2"
G
2"
G 2"G 2"G 2"G 2"G 2"
G
G
SA
N
8"
WV
D
W8"W8"W8"W8"W8"
ST
42
"
ST
42
"
S
D D
D
S
D
ST
42
"
ST
42
"
ST
42
"
ST
42
"
ST
42
"
ST
42
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST 15"
S
S
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
SA
N
10
"
S
A
N
1
0
"
SAN10"
SA
N
10
"
G
G
G
G
U/E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U
/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
U/
E
ST
8"
ST
8"
ST
15"
S
T
1
5
"
D
REGIONAL DETENTION POND
102
7
1028
1
0
2
6
1025
1
0
2
6
1
0
2
7
1
0
2
9
1
0
3
0
1
0
3
1
1
0
3
0
10
2
9
10
2
5
1020
1017
1
0
2
1
102
1
102
2
10
2
2
10
2
5
1023
10
2
3
1024
1
0
2
3
1025
10
2
5
10
2
5
10
2
3
1
0
2
0
1
0
1
9
1017
1
0
2
0
1
0
2
1
1
0
2
2
10
2
2
1
0
2
0
102210
2
3
1
0
2
5
10
3
1
10
3
0
10
2
9
1
0
2
8
1
0
2
7
10
2
4
10
2
3
1021
1020
101
9
101
8
10
1
7
1017
101
8
10
1
9
1019
1020
1021
10
2
2
1023
1022
10
2
3
10
2
3
1
0
2
5
10
2
1
102
0
10
2
3
10
2
3
1022
1
0
2
2
1020
1017
1
0
2
6
10
2
3
10
2
2
10
2
1
1
0
2
0
10
1
9
10
1
8
10
1
7
1
0
1
8
1
0
1
9
1
0
2
3
10
2
3
102
4
10
2
5
1
0
2
3
10
2
3
1022
1022
10
2
3
10
2
2
10
3
1
1024.33
1024.60 1024.60
1025.00
100 YEAR PONDING
ELEV. = 1020.48
PROP. BUILDING
PROP. 34,150 SQ. FT.
FF=1023.50'
HT.=23.00
WV
A/
C
FF=1023.50
(PER 2018 DESIGN
REF. PROJECT #180108)
HYD
HYD
HY D
D
D
CO
CO CO
CO CO
CO
CO
S
79
.
0
0
'
N0
0
°
2
0
'
0
6
"
E
79
.
0
0
'
S0
0
°
2
0
'
0
6
"
W
32.00'
N89°49'20"W
32.00'
S89°49'20"E
INGRESS/EGRESS
EASEMENT
COCO CO
CO
CO CO
CO
CO
PRIVATE
WATERMAIN
EASEMENT
30.00'
S89°48'24"E
32
.
0
0
'
N0
0
°
2
0
'
0
6
"
E
30.00'
N89°48'24"W
32
.
0
0
'
S0
0
°
2
0
'
0
6
"
W
D
RO
3
SH
1
WO
3
RO
3
WO
3
DF
5
NS
3
GB
2
JT
3
GB
1
RO
4
ER
1PD
8
GL
10
GF
14
CV
5
LB
16
LD
6
LB
16
GL
6
SOD
SOD
SOD
SOD
SOD
SOD
SOD
GF
5
BD
9
GF
8
BD
9
GF
5
DF
2
SH
1
KC
1
SODKC
1
ER
1
SH
1
GL
6
GB
1
DY
10
PD
15
SOD
KF
8
EDGING
EDGING
EDGING BETWEEN ROCK
AND PLANTING BED
SOD
EDGING
LANDSCAPE NOTES:
1.ALL SODDING & LANDSCAPE PLANTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE URBAN STANDARD
SPECIFICATIONS, UNLESS SPECIFIED OTHERWISE.
2.SOD ALL DISTURBED AREAS WITHIN THE CONTRACT LIMITS (INCLUDING RIGHT OF WAY) UNLESS NOTED
OTHERWISE.
3.PLANT QUANTITIES ARE FOR CONTRACTORS CONVENIENCE, THE DRAWING SHALL PREVAIL IF A CONFLICT
OCCURS.
4.ALL PLANT MATERIAL SHALL CONFORM TO THE LATEST EDITION OF THE AMERICAN STANDARD FOR NURSERY
STOCK (ANSI Z60.1).
5.CONTRACTOR SHALL GUARANTEE ALL PLANT MATERIAL FOR A PERIOD OF ONE YEAR FROM THE DATE OF
ACCEPTANCE.
6.IT IS THE CONTRACTORS RESPONSIBILITY TO REMOVE IDENTIFICATION TAGS AND CORDS ON ALL PLANT
MATERIAL PRIOR TO THE COMPLETION OF THE CONTRACT. IDENTIFICATION TAGS MUST BE LEFT ON UNTIL
AFTER ACCEPTANCE BY OWNER OR OWNER'S REPRESENTATIVE.
7.CONTRACTOR SHALL PLACE SHREDDED HARDWOOD MULCH AROUND ALL TREES, SHRUBS AND GROUND
COVER BEDS TO A DEPTH OF 4 INCHES, UNLESS NOTED. DO NOT PLACE MULCH AROUND PLANTS WITHIN
ROCK LANDSCAPE BEDS.
8.STAKE AND WRAP ALL DECIDUOUS TREES IMMEDIATELY AFTER PLANTING. STAKE ALL TREES ACCORDING TO
THE STAKING DETAILS. CONTRACTOR SHALL ADJUST AND MAINTAIN GUYING TENSION THROUGHOUT THE
PLANT ESTABLISHMENT PERIOD.
9.THE LANDSCAPING CONTRACTOR SHALL HAVE ALL UTILITIES LOCATED BEFORE STARTING ANY SITE WORK OR
PLANTING. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING UTILITIES.
10.NO LANDSCAPE MATERIAL SHALL BE SUBSTITUTED WITHOUT THE AUTHORIZATION OF THE LANDSCAPE
ARCHITECT. ANY SUBSTITUTIONS SHALL REQUIRE APPROVAL FROM THE CITY OF WAUKEE COMMUNITY
DEVELOPMENT DEPARTMENT.
11.CONTRACTOR SHALL BE RESPONSIBLE MAINTAINING APPROPRIATE LEVEL OF WATERING FOR ALL NEW
PLANTS FOR A PERIOD OF 30 DAYS.
12.ALL EDGING SHALL BE DURAEDGE 1/8" STEEL EDGING - COLOR BLACK, OR APPROVED EQUAL
13.ALL SHRUB AND PERENNIAL PLANTING BEDS SHALL INCORPORATE TYPAR 3301 NONWOVEN LANDSCAPE
FABRIC (OR SIMILAR) AND 3" THICK LAYER OF WASHED RIVER ROCK (1.5" NOMINAL SIZE).
14.ALL BEDS TO RECEIVE GRANULAR PRE-EMERGENT WEED CONTROL BEFORE AND AFTER ROCK IS INSTALLED.DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
#
IS
S
U
E
D
A
T
E
NB
I
#
:
-
-
-
-
-
-
-
-
DB
S
#
:
2
2
-
3
-
4
4
2
DR
A
W
N
B
Y
:
G
S
A
CH
E
C
K
E
D
B
Y
:
S
V
S
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
#
IS
S
U
E
D
A
T
E
ST
I
V
E
R
S
GE
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
-
A
R
C
H
I
T
E
C
T
14
3
5
o
h
i
o
s
t
r
e
e
t
/
p
.
o
.
b
o
x
1
3
1
5
/
d
e
s
m
o
i
n
e
s
,
i
a
5
0
3
0
5
-
1
3
1
5
ph
o
n
e
:
(
5
1
5
)
2
4
3
-
0
1
5
6
/
f
a
x
:
(
5
1
5
)
2
4
3
-
0
1
6
5
NE
U
M
A
N
N
B
R
O
T
H
E
R
S
,
I
N
C
.
-
D
E
S
I
G
N
B
U
I
L
D
S
O
L
U
T
I
O
N
S
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Copyright DesignBuild Solutions, LC. Protected under Architectural Works Copyright Protection Act of 1990.
FIELD BULLETINS
ASSOCIATED WITH
THIS SHEET:
01
/
1
1
/
2
0
2
3
1S
T
C
I
T
Y
S
U
B
M
I
T
T
A
L
04
/
0
6
/
2
0
2
3
2N
D
C
I
T
Y
S
U
B
M
I
T
T
A
L
06
/
1
6
/
2
0
2
3
3R
D
C
I
T
Y
S
U
B
M
I
T
T
A
L
08
/
2
8
/
2
0
2
3
4T
H
C
I
T
Y
S
U
B
M
I
T
T
A
L
09
/
1
3
/
2
0
2
3
5T
H
C
I
T
Y
S
U
B
M
I
T
T
A
L
12
/
1
9
/
2
0
2
2
5
:
0
0
:
1
3
P
M
FO
R
D
P
R
O
C
E
N
T
E
R
13
5
0
S
E
S
t
o
n
e
R
i
d
g
e
D
r
i
v
e
,
W
a
u
k
e
e
,
I
o
w
a
5
0
2
6
3
GRAPHIC SCALE
030 15 30 60
DO NOT CUT CENTRAL LEADER
WRAP TRUNK WITH APPROVED
TREE WRAP TO FIRST BRANCH
4" DEEP HARDWOOD MULCH
CUT SYNTHETIC CORDS AROUND
ROOTBALL AND TRUNK -ENTIRELY
REMOVE WIRE BASKETS FROM BALL
SET ROOTBALL ON UNDISTURBED
SUBGRADE
DECIDUOUS TREE PLANTING (TYP.)
NOT TO SCALESCALE:
SCARIFY SIDES & BOTTOM OF
PLANTING PIT
STAKING ORIENTATION
NORTH NORTH
2 STAKES - 3" CAL. & LESS
3 STAKES - GREATER THAN 3" CAL.
3'-0"SET ROOTBALL FLUSH WITH
FINISHED GRADE
DO NOT PLACE MULCH IN
CONTACT WITH BASE OF TREE
PRUNE ANY DEAD/DAMAGED
BRANCHING FROM TREE.
MAINTAIN OVERALL APPEARANCE.
USE HOSE GUARDS AROUND
TRUNK ON STAKING WIRE. TIE
WIRE TO STEEL POSTS PLACED
OUTSIDE PLANT PIT..
LEAVE STAKES IN PLACE NO MORE
THAN 1 YEAR FROM INSTALLATION.
CONTRACTOR RESPONSIBLE FOR
REMOVAL.
4" DEPTH SHREDDED HARDWOOD
MULCH
SCARIFY SIDES & BOTTOM OF
PLANTING PIT
EVERGREEN TREE PLANTING (B&B)
NOT TO SCALESCALE:
CUT SYNTHETIC CORDS AROUND
ROOTBALL AND TRUNK -ENTIRELY
REMOVE WIRE BASKETS FROM BALL
SET ROOTBALL ON UNDISTURBED
SUBGRADE
3'-0"
DO NOT PLACE MULCH IN
CONTACT WITH BASE OF TREE
DECIDUOUS SHRUB DETAIL EVERGREEN SHRUB DETAIL
PLANTING ON SLOPES
FIRMLY COMPACT SAUCER
(USE TOPSOIL)
ORIGINAL GROUND LINE
SUB-SOIL
4" MULCH
PLANTING PIT TWICE
THE WIDTH OF ROOTBALL
1
2
SHRUB PLANTING (TYP)
NOT TO SCALESCALE:
L:
\
L
A
N
D
P
R
O
J
E
C
T
S
2
0
2
2
\
2
2
0
3
2
8
\
D
W
G
\
C
5
L
A
N
D
S
C
A
P
E
.
D
W
G
9/
1
3
/
2
0
2
3
1
:
5
7
:
4
2
P
M
DO NOT CUT CENTRAL LEADER
PLANTING SCHEDULE
C5.1
LANDSCAPE
PLAN
SITE LANDSCAPE REQUIREMENTS
TOTAL SQUARE FOOTAGE OF TOTAL SITE AREA 220,399 SF
REQUIRED OPEN SPACE(20%)44,080 SF
GENERAL OPEN SPACE REQUIREMENT
TOTAL REQUIRED TREES (1 PER 1000 SF OF REQUIRED OPEN SPACE 44
50% MUST BE OVER STORY TREES 22 MINIMUM
TOTAL REQUIRED SHRUBS (1 PER 1000 SF OF REQUIRED OPEN SPACE)44
TOTAL PLANTINGS
PROPOSED OVERSTORY TREES 25
EXISTING OVERSTORY TREES TO REMAIN 4
PROPOSED UNDERSTORY TREES 5
PROPOSED EVERGREEN TREES 10
TOTAL SITE TREES 44
TOTAL PROPOSED SHRUBS 83
PARKING PERIMETER (SE STONE RIDGE DRIVE)
TOTAL LENGTH OF LOT 108 LNFT
TOTAL REQUIRED TREES (1 PER 40 LNFT)3
NOTE: ONE EXISTING OVERSTORY TREE (GINKGO) IS BEING REMOVED AT THE NORTH
END OF THE DIVIDING ISLAND BETWEEN THE TWO SITES. THIS TREE IS BEING
REPLACED AT THE SOUTH END OF THE ISLAND. NO OTHER EXISTING TREES FROM
THE PREVIOUSLY APPROVED SITE PLAN ARE BEING REMOVED.
SOD: PROVIDE AND INSTALL SOD FROM LOCAL SUPPLIERS. AREAS TO BE SODDED MUST BE FREE OF ALL CONSTRUCTION DEBRIS
AND ANY DIRT CLUMPS OVER 1" IN DIAMETER. THOROUGHLY WATER SOD UPON INSTALLATION. CONTRACTOR TO MAINTAIN
WATERING UNTIL SOD IS ESTABLISHED (ROOTS KNITTED INTO SUBSURFACE)
EXISTING PLAN LEGEND
OVERSTORY
UNDERSTORY
EVERGREEN
NOTE: AT TIME OF PLANTING OVERSTORY TREES MUST BE A MINIMUM OF 8' HEIGHT, ORNAMENTAL AND EVERGREEN TREES MUST BE A MINIMUM OF 6' HEIGHT.
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
#
IS
S
U
E
D
A
T
E
NB
I
#
:
-
-
-
-
-
-
-
-
DB
S
#
:
2
2
-
3
-
4
4
2
DR
A
W
N
B
Y
:
G
S
A
CH
E
C
K
E
D
B
Y
:
S
V
S
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
#
IS
S
U
E
D
A
T
E
ST
I
V
E
R
S
GE
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
-
A
R
C
H
I
T
E
C
T
14
3
5
o
h
i
o
s
t
r
e
e
t
/
p
.
o
.
b
o
x
1
3
1
5
/
d
e
s
m
o
i
n
e
s
,
i
a
5
0
3
0
5
-
1
3
1
5
ph
o
n
e
:
(
5
1
5
)
2
4
3
-
0
1
5
6
/
f
a
x
:
(
5
1
5
)
2
4
3
-
0
1
6
5
NE
U
M
A
N
N
B
R
O
T
H
E
R
S
,
I
N
C
.
-
D
E
S
I
G
N
B
U
I
L
D
S
O
L
U
T
I
O
N
S
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Copyright DesignBuild Solutions, LC. Protected under Architectural Works Copyright Protection Act of 1990.
FIELD BULLETINS
ASSOCIATED WITH
THIS SHEET:
01
/
1
1
/
2
0
2
3
1S
T
C
I
T
Y
S
U
B
M
I
T
T
A
L
04
/
0
6
/
2
0
2
3
2N
D
C
I
T
Y
S
U
B
M
I
T
T
A
L
06
/
1
6
/
2
0
2
3
3R
D
C
I
T
Y
S
U
B
M
I
T
T
A
L
08
/
2
8
/
2
0
2
3
4T
H
C
I
T
Y
S
U
B
M
I
T
T
A
L
09
/
1
3
/
2
0
2
3
5T
H
C
I
T
Y
S
U
B
M
I
T
T
A
L
12
/
1
9
/
2
0
2
2
5
:
0
0
:
1
3
P
M
FO
R
D
P
R
O
C
E
N
T
E
R
13
5
0
S
E
S
t
o
n
e
R
i
d
g
e
D
r
i
v
e
,
W
a
u
k
e
e
,
I
o
w
a
5
0
2
6
3
L:
\
L
A
N
D
P
R
O
J
E
C
T
S
2
0
2
2
\
2
2
0
3
2
8
\
D
W
G
\
C
6
D
E
T
A
I
L
S
.
D
W
G
9/
1
3
/
2
0
2
3
5
:
1
7
:
4
5
P
M
HEAVY DUTY PAVEMENT SECTION
NOT TO SCALE
1
C6.1
SIDEWALK DETAIL
NOT TO SCALE
FINISHED GROUND GRADE
(INCLUDING SOD) SHALL BE
1/4" BELOW FINISHED PAVEMENT
GRADE ON DOWNHILL SIDE
WIDTH PER PLAN
5" PCC (UNLESS NOTED OTHERWISE)
NOTE: SLOPE SIDEWALK IN
ACCORDANCE WITH GRADING PLAN,
1.5% CROSS SLOPE
6" COMPACTED SUBASE
2
C6.1
RESERVED
PARKING
ACCESSIBLE PARKING SIGN
NOT TO SCALE
MUTCD R7-8
TRANSFORMER PAD MOAT DETAIL
NOT TO SCALE
REINFORCED CONCRETE
TRANSFORMER PAD (PER
MID-AMERICAN STANDARDS)
REFERENCE ELECTRICAL PLANS
TRANSFORMER
3'
3'
3'
3'
3" RIVER ROCK,
SCREENED
DURAEDGE 1/8"
STEEL EDGING,
COLOR GREEN
REINFORCED CONCRETE
TRANSFORMER PAD (PER
MID-AMERICAN STANDARDS)
3" RIVER ROCK,
SCREENED
3'
2'2'
3'LINE TRENCH WITH SILT FENCE
FABRIC (OR OTHER SOIL FABRIC
WITH EQUAL OR LOWER
POROSITY)
DURAEDGE 1/8"
STEEL EDGING,
COLOR GREEN
12"
SLOPE PER PLANS 1.5% MAX CROSS SLOPE
ROADWAY PAVEMENT
6" MAX
24" MIN
(DIRECTION SHOWN ON GRADING PLANS)
VARIES
1" NOMINAL
5/8"RESILIENT JOINT FILLER
1/2" GRAY MASTIC JOINT
SEALANT MATERIAL
DETAIL A: NOT TO SCALE
EDGE WITH 1/4 INCH TOOL FOR LENGTH OF JOINT
INDICATED IF FORMED; EDGING NOT REQUIRED
WHEN CUT WITH DIAMOND BLADE SAW
1"
1" NOMINAL
NOTES:
*IMPORTANT:* 1" EXPANSION JOINT BETWEEN
ROADWAY PAVEMENT AND WALK MUST BE
INSTALLED TO FULL DEPTH OF SLAB.
5"
5"6"
TURNED DOWN WALK DETAIL
SCALE NONE
4
C6.1
FINISH W/ 3/4" RADIUS TOOL
SEALED 'E' JOINT
SEE DETAIL A
& NOTES
SEE PAVEMENT SECTION
FOR SUBGRADE INFO
IF ROCK IS USED UNDER
ROADWAY PAVEMENT, CONTINUE
ROCK UNDER SIDEWALK
PAVEMENT, MATCH SECTION
SEALED 'E' JOINT
SEE DETAIL A
& NOTES
BUILDING WALL
(WHERE APPLICABLE)
#4 BARS 24" O/C BOTH WAYS
ALL REINFORCEMENT SHALL
BE EPOXY COATED
P
a
r
a
l
l
e
l
R
a
m
p
(
i
f
r
e
q
u
i
r
e
d
)
St
a
n
d
a
r
d
Si
d
e
w
a
l
k
1'-0
"
(typ
.
)
Grade Break
Special Shaping
Parallel Curb Ramp: If normal sidewalk
elevation cannot be achieved with the
perpendicular ramp between the street
and landing due to limited ramp length,
provide a parallel ramp to make up the
elevation difference between the
landing and the standard sidewalk.
The length of the parallel ramp is not
required to exceed 15 feet, regardless
of the resulting slope. Do not exceed
8.3% slope for parallel ramps shorter
than 15 feet.
Turning Space: Target slope of 1.5%
with maximum slope perpendicular to the
travel directions of 2.0%. Minimum 5
feet by 5 feet.
Perpendicular Curb Ramp: Target
running slope of 6.25% with maximum
running slope of 8.3%.
Target cross slope of 1.5% with a
maximum cross slope of 2.0%.
Match pedestrian street crossing cross
slope or flatter.
5
6
7
8
7 7
5
6
8
8
9
9
5'
M
I
N
5' MI
N
VARIES
3 ADA RAMP DETAILS
SCALE NONEC6.1
1
2
3
Locate 'DW' joint at a mid-panel location between future
'C' or 'CD' joints. Place no closer than 5 feet to a 'C' or
'CD' joint.
Place bars within the limits shown under dowel
assemblies.
'RT' joint may be used in lieu of 'DW' joint at the end of
the days work. Remove any pavement damaged due to
the drilling at no additional cost to the Contracting
Authority.
4 Saw 'C' joint to a depth of T/3.
6
7
5 Bar supports may be necessary for fixed form paving to
ensure the bar remains in a horizontal position in the
plastic concrete.
Sawing or sealing of joint not required.
The following joints are interchangeable, subject to the
pouring sequence:
'BT-1' and 'L-1'
'BT-2' and 'L-2'
'BT-3' and 'L-3'
1
2" to 3
4''Top of Pavement
Sealant
SECTION A-A
(Detail at Edge of Pavement)
DETAIL C
Joint Sealant Material
1
4'' ± 1
16'' Saw Cut
1 1
4'' ± 1
4'' Saw Cut
1
4'' ± 1
8''
Crack or
Joint Line
A
A
Pavement Edge See Detail C
T
Hole Diameter 1
8''
Larger than Dowel
8
18'' Long 3/4" Dowel
at 12'' Centers
9'' min.9'' min.
'RD'
ABUTTING PAVEMENT JOINT
8 Edge with 1/4 inch tool for length of joint indicated if
formed; edging not required when cut with diamond
blade saw. Remove header block and board when
second slab is placed.
T/2
T
See Detail A or B
T
30'' Long Tie Bar
at 12'' Centers
321
'C'
CONTRACTION JOINT
'DW'
DAY'S WORK JOINT (Non-working)
5 7
30'' Long #4 BarsSee Detail E
See Detail D-1 or D-2
7
6
'KT-1'
ABUTTING PAVEMENT JOINT - KEYWAY TIE
'L-1'
CONTRACTION JOINT
1
4'' ± 1
16'' Saw CutJoint Sealant Material
1
4'' ± 1
8''
Saw Cut 4
A
A
Crack or
Joint Line
1
8'' to 5
16'' Saw CutJoint Sealant Material
1
4'' ± 1
8''
1 1
4'' ± 1
4''
Crack or
Joint Line
A
A
DETAIL B
(Saw cut formed by approved early concrete sawing equipment.)
DETAIL A
(Saw cut formed by conventional concrete sawing equipment.)
at 30'' Centers
36'' Long #4 Bars
at 30'' Centers
T/2
1'' + 1
4'' or - 1
8''
1"2"
DETAIL E
Crack or
Joint Line
T/3 ± 1
4''
Crack or
Joint Line
T/3 ± 1
4''
Joint Sealant Material
1
8'' ± 1
16'' Saw Cut
1
4'' ± 1
16'' Saw Cut
DETAIL D-1
DETAIL D-2
13
(Required when the Department of Transportation
is not the Contracting Authority, or when
specified in the contract documents)
(Required when the Department of Transportation
is the Contracting Authority, or when
specified in the contract documents.)
JOINTING DETAILS
SCALE NONE
5
C6.1
ACCESSIBLE PARKING SIGN
NOT TO SCALE
MUTCD R7-8
HANDICAPPED
PARKING SIGN
'VAN ACCESSIBLE' SIGN FOR
VAN ACCESSIBLE SPACE
MUTCD R7-8p
2" STEEL ROUND
OR SQUARE PIPE
PAVING OR
SIDEWALK (TYP)MOWING
EDGE
P.C.C. FOOTING
10
C6.1
PVC & N-12 PIPE BEDDING
SCALE NONE
7
C6.1
BACK OF CURB
FACE OF CURB EDGE OF TURNED DOWN WALK
SIDEWALK PAVEMENT
GRASS/LANDSCAPING
ROADWAY PAVEMENT
PLAN VIEW
CURB & GUTTER / TURNED DOWN WALK TRANSITION DETAIL
SCALE NONE
12
C6.1
9
C6.1
NOTES:
1.SLOPE GUTTER IN ACCORDANCE WITH GRADING PLAN.
2.GEOTECHNICAL REPORT WAS NOT DONE FOR THIS PROJECT
R 2"
R 1"
7"
6"
4.5"3"
12" COMPACTED
SUBGRADE
95% STD PROCTOR
7" P.C.C.
(C4 MIX)
2-6" LIFTS
DOWNSPOUT (REF ARCH)
4" N-12 PIPE
FLOOR SLAB PROPOSED GROUND
INSTALL CAP ON STORM PIPE AND
EXTEND DOWNSPOUT INTO CAP COVER
EXTERIOR WALL
FOUNDATION WALL
5'
M
I
N
D
E
P
T
H
DOWNSPOUT CONNECTION DETAIL
SCALE NONE
90° BEND
CONNECT TO 8" STORM
SEWER W/ WYE
6
C6.1
C6.1
DETAILS
SHEET
STORM CLEANOUT DETAIL
SCALE NONE
13
C6.1
NYLOPLAST COUPLING
(ADS CODE 1579 AG) SCH. 40 PVC TO N-12
(REDUCING COUPLING AS NECESSARY)
SCH. 40 PVC ROOF
DRAIN LINE (REF MECH)
HDPE STORM SEWER
(SEE SITE PLAN)
ROOF DRAIN CONNECTION DETAIL
SCALE NONE
8
C6.1
D
42
"
VARIES
SAME DIMENSION AS END SECTION
FLARED END
SECTION
A
A
42
"
ELEVATION
SECTION A-A
#4 BARS @ 18" ON CENTER
UNDISTURBED SOIL
PIPE BEDDING
CONCRETE FOOTING
6"
1'- 8"
FLARED END SECTION
W/ TRASH GUARD
FLARED END SECTION DETAIL
SCALE NONE
14
C6.1
CITY OF WAUKEE HYDRANT DETAIL
SCALE NONE
18
C6.1
0" TO 6"
XXX
#4 @ 12" O.C.
THUS:60"
36"
#4 @ 12" O.C.
STRUCTURAL
STOOP-
SEE STRUCTURAL
KEYED
JOINT
4" VOID FORMS
X WIDTH OF
SIDEWALK
2"
5'-0"
SIDEWALK
1/4" EXPANSION JOINT
FILLED W/ GRAY
MASTIC JOINT SEALANT
12"
6" PCC
12"
STRUCTURAL STOOP / SIDEWALK TRANSITION DETAIL
SCALE NONE
17
C6.1
5"
AMMENDED SOILS NOTES (I.S.W.M. CH. 5 SEC 4)
BIORETENTION MAINTENANCE NOTES (I.S.W.M. CH. 5 SEC 4)
GENERAL NOTES:
1.FURTHER DETAILS AND DESCRIPTIONS OF BIORETENTION SYSTEMS CAN BE FOUND
IN THE IOWA STORM WATER MANAGEMENT MANUAL, CHAPTER 5, SECTION 4.
2.CONTRACTOR TO CONTACT BISHOP ENGINEERING (515-276-0467) WITH 10 BUSINESS
DAY LEAD TIME FOR THE AS-BUILT SURVEY OF THE ABOVE GROUND BIORETENTION
AREA. PRIOR TO INSTALLATION, THE CONTRACTOR IS TO VERIFY WITH THE CITY
THAT THE BIORETENTION CELL WAS INSTALLED PER REQUIREMENTS LAID OUT IN
THE IOWA STORM WATER MANAGEMENT MANUAL, CHAPTER 5 SECTION 4.THESE
FACILITIES SHALL NOT BE CONSTRUCTED UNTIL ALL UPSTREAM AREAS ARE
STABILIZED.
6-
9
"
P
O
N
D
I
N
G
D
E
P
T
H
SHEET FLOWSHEET FLOW
POND BOTTOM
POND TOP 6" DEPTH
SOIL
UNDISTURBED
SOIL
AMENDED SOIL
(75-90% CONCRETE SAND, 0-10%
ORGANIC COMPOST, 0-25% SOIL
A-HORIZON
3/8" CHIP LIMESTONE (CHOKER LAYER)
1" LIMESTONE (CLEAN)
NOT TO SCALE
6" PERFORATED PVC SUBDRAIN
18
"
SO
I
L
D
E
P
T
H
2"
12
"
BIORETENTION DETAIL
NOTE:
REFER TO IOWA STORMWATER
MANAGEMENT MANUAL, CHAPTER 5
SECTION 4 (C5-S4-BIORETENTION
SYSTEMS) FOR FURTHER DETAILS
15
C6.1
24" RCP INLET
FL ELEV. = 1,017.77
WEIR WALL
ELEVATION = 1,019.57 (CPV ELEV)
WEIR LENGTH = WIDTH OF MANHOLE
3" DIA. HOLE
ELEV. = 1,014.00
OWNER SHALL CLEAN OUT
ORIFICE AS NECESSARY
RIM = 1,022.00
18" RCP OUTLET
FL ELEV. = 1,013.75
NORTH BASIN STRUCTURE #10A MODIFIED SW-401(48" DIA)
SCALE NONE
16
C6.1
6" SUBDRAIN INLET
FL ELEV. = 1,014.20
6" CONCRETE WEIR WALL
WQV = 9,255 CF
WQV EL = 1,018.75'
1-YR VOLUME = 10,102 CF
1-YR HWL = 1,019.57
FES ELEV = 1,018.75'
BASIN BTM ELEV = 1,018.00'
NOTE** WQV EL IS
CONTROLLED BY INLET FES
ELEVATION.
TRASH GUARD OVER
OPENING
18" RCP INLET
FL ELEV. = 1,017.34
WEIR WALL ELEVATION = 1,020.01
WEIR LENGTH = WIDTH OF MANHOLE
3" DIA. HOLE
ELEV. = 1,017.24
OWNER SHALL CLEAN OUT
ORIFICE AS NECESSARY
18" RCP OUTLET
FL ELEV. = 1,017.24
2' SUMP
DEPTH
SOUTH BASIN STRUCTURE #15A MODIFIED SW-401 (48" DIA)
SCALE NONE
19
C6.1
6" CONCRETE WEIR WALL
WQV = 4,363 CF
WQV EL = 1,019.25'
1-YR VOLUME = 4,456 CF
1-YR HWL = 1,020.01'
FES ELEV = 1,019.25'
BASIN BTM ELEV = 1,018.50
NOTE** WQV EL IS
CONTROLLED BY INLET FES
ELEVATION
TRASH GUARD OVER
OPENING
RIM = 1,023.45
CONTRACTOR TO FILL
BOTTOM OF STRUCTURE
WITH FILLABLE MORTAR TO
PROVIDE POSITIVE
DRAINAGE FROM ORIFICE
OPENING TO INLET AND
OUTLET PIPE
6" SUBDRAIN INLET
FL ELEV. = 1,017.34
2' SUMP
DEPTH
CONTRACTOR TO FILL
BOTTOM OF STRUCTURE
WITH FILLABLE MORTAR TO
PROVIDE POSITIVE
DRAINAGE FROM ORIFICE
OPENING TO INLET AND
OUTLET PIPE
48" DIA.
48" DIA.
INTAKE SUMP DETAIL
SCALE NONE
20
C6.1
INSPECTION/MAINTENANCE NOTE:
1.OWNER TO HIRE AND/OR PERFORM ANNUAL
INSPECTION AND MAINTENANCE OF MODIFIED
OUTLET STRUCTURE. THIS MAY INCLUDE BUT IS
NOT LIMITED TO REMOVAL/CLEANING OF ALL
DEBRIS, SILT AND TRASH ACCUMULATED IN THE
BASIN AND MODIFIED OUTLET STRUCTURES.
2.IF ANY PROLONGED PONDING OR DEBRIS IS
OBSERVED IN THE BASIN, THE OWNER SHALL
PERFORM MAINTENANCE ON A MODIFIED
SCHEDULE AS NEEDED TO KEEP THE BASIN CLEAR
OF DEBRIS, SILT AND TRASH.
INSPECTION/MAINTENANCE NOTE:
1.OWNER TO HIRE AND/OR PERFORM ANNUAL INSPECTION AND MAINTENANCE
OF MODIFIED OUTLET STRUCTURE. THIS MAY INCLUDE BUT IS NOT LIMITED
TO REMOVAL/CLEANING OF ALL DEBRIS, SILT AND TRASH ACCUMULATED IN
THE BASIN AND MODIFIED OUTLET STRUCTURES.
2.IF ANY PROLONGED PONDING OR DEBRIS IS OBSERVED IN THE BASIN, THE
OWNER SHALL PERFORM MAINTENANCE ON A MODIFIED SCHEDULE AS
NEEDED TO KEEP THE BASIN CLEAR OF DEBRIS, SILT AND TRASH.
INLET
OUTLET
SUMP DEPTH
(VARIES, SEE PLANS)
INSPECTION/MAINTENANCE NOTE:
1.OWNER TO HIRE AND/OR PERFORM ANNUAL INSPECTION AND MAINTENANCE OF MODIFIED OUTLET
STRUCTURE. THIS MAY INCLUDE BUT IS NOT LIMITED TO REMOVAL/CLEANING OF ALL DEBRIS, SILT AND TRASH
ACCUMULATED IN THE BASIN AND MODIFIED OUTLET STRUCTURES.
2.IF ANY PROLONGED PONDING OR DEBRIS IS OBSERVED IN THE BASIN, THE OWNER SHALL PERFORM
MAINTENANCE ON A MODIFIED SCHEDULE AS NEEDED TO KEEP THE BASIN CLEAR OF DEBRIS, SILT AND
TRASH.
1023.09G
1023.17G
1022.60G
1022.68G
1023.59T/C
1023.21E/W
1023.29E/W1023.36E/W
1023.29E/W
1023.17E/W
1023.67T/C
1.
5
%
1.
5
%
1.5%1.5%
1.5%
1.
5
%
1.5%
1.2%
1.2%
1.2%
1.2%2.7%
1.2%
1.
5
%
1.0%
1.0%
1.
5
%
1.
5
%
1023.10T/C
1023.18T/C
1022.68E/W
1022.52E/W
1022.60E/W 1022.55E/W
1022.47E/W
1.9%
1.9%
1022.96E/W1022.89E/W
1022.91E/W1022.84E/W
1022.34G
1022.41G
1022.91T/C
1022.84T/C
1.5%
1.5%
1.5%
1.0%
1022.24E/W 1022.19E/W
1022.95T/C
1022.45G
1.
5
%
1.
5
%
4.
4
%
4.
3
%
0.
8
%
0.
8
%
1.
5
%
6.
4
%
6.
3
%
1.
0
%
1.
0
%
1.0%
1.0%
1.
3
%
1.
3
%
1.
7
%
2.
0
%
1.2%
1.2%
5.0%
5.0%
1019.17E/W
1019.09E/W
1019.03E/W
1018.94E/W
1018.77E/W
1018.70G
1018.68G
3.0%
3.0%3.0%
3.0%
1.
5
%
1.
5
%
1.
5
%
0
.
4
%
1019.04T/C EX.
1019.18T/C
1019.42T/C
1018.92G
1018.54 EX.
2.
0
%
3.1%
2.3%
3.1%
2.9%
1017.56 EX.1018.00 EX.
1019.02 EX.
1018.98 EX.
1018.21
1018.41
1017.78 EX.
1018.09 EX.
1023.29T/C
1022.79G
1022.61
1023.11T/C
1022.61G
1023.17T/C
1022.67G
1023.29T/C
1022.79G
1023.16T/C
1022.66G
1023.34T/C
1022.84G
1023.29T/C
1022.79G 1023.29T/C
1022.79G
1022.51
1022.51
1023.29T/C
1022.79G
1023.411023.41 1023.41
1023.29T/C
1023.411022.911022.911023.411023.411023.41
1023.501023.50 1023.50
1023.501023.50
1023.50
1023.50
1022.79T/C 1022.79T/C
1023.23T/C
1022.73G
0.0%
1.
5
%
0.0%0.0%
1.
5
%
1.
5
%
0.0%
0.0%
0.0%
0.0%
0.0%
1.
5
%
1.
5
%
1.
5
%
1.
5
%
6.2%0.0%6.2%
1.
5
%
1.
5
%
0.0%0.0%
1.
5
%
0.2%
0.0%
1
.
0
%
0.4%1.5%
0.0%0.0%
1.
5
%
5.
0
%
0.
6
%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
6.2%
0.0%
1.9%
1.
0
%
1
.
0
%
1.
5
%
0.2%
0.1%
0.0%
6.2%0.0%0.0%0.0%
1.
5
%
1.
5
%
1022.79G 1022.79G
1022.62G
1022.69G
1023.02T/C
1022.52G
1023.12T/C 1023.19T/C
1023.12E/W 1023.19E/W
1023.17E/W
1023.29E/W
1023.29E/W
1023.24E/W
1023.21E/W
1023.38E/W
1023.19T/C
1022.69G
1023.26T/C
1022.76G
1023.38E/W
1023.30T/C
1022.80G
1.5%1.0%
0.
0
%
1.5%
1.
7
%
2.
1
%
2.
2
%
0.
8
%
1.5%
1.
0
%
1.
0
%
1.5%
6.
3
%
6.
3
%
0.
9
%
0.
9
%
0.
7
%
0.
7
%
0.
8
%
0.
8
%
1.5%
1023.07T/C
1022.57G
1025.14E/W
1024.80E/W
1025.23E/W1025.15E/W
1.5%
1.9%
1.9%
1.
6
%
1024.33±G EX.
1.
5
%
1.
6
%
1025.22E/W
1024.72E/W1024.68E/W
1024.52±G EX.
1024.62±T/C EX.
1025.00±T/C EX.
1024.72E/W
1024.57E/W
1024.68E/W
6.0%
6.0%1.5%
1.
7
%
1.
0
%
1.
5
%
6.
0
%
0.9%
7.
8
%
1.0%
7.
8
%
6.
0
%
8.
0
%
CONCRETE DRIVEWAY
SCALE NONE
1
C6.2
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
#
IS
S
U
E
D
A
T
E
NB
I
#
:
-
-
-
-
-
-
-
-
DB
S
#
:
2
2
-
3
-
4
4
2
DR
A
W
N
B
Y
:
G
S
A
CH
E
C
K
E
D
B
Y
:
S
V
S
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
#
IS
S
U
E
D
A
T
E
ST
I
V
E
R
S
GE
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
-
A
R
C
H
I
T
E
C
T
14
3
5
o
h
i
o
s
t
r
e
e
t
/
p
.
o
.
b
o
x
1
3
1
5
/
d
e
s
m
o
i
n
e
s
,
i
a
5
0
3
0
5
-
1
3
1
5
ph
o
n
e
:
(
5
1
5
)
2
4
3
-
0
1
5
6
/
f
a
x
:
(
5
1
5
)
2
4
3
-
0
1
6
5
NE
U
M
A
N
N
B
R
O
T
H
E
R
S
,
I
N
C
.
-
D
E
S
I
G
N
B
U
I
L
D
S
O
L
U
T
I
O
N
S
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Copyright DesignBuild Solutions, LC. Protected under Architectural Works Copyright Protection Act of 1990.
FIELD BULLETINS
ASSOCIATED WITH
THIS SHEET:
01
/
1
1
/
2
0
2
3
1S
T
C
I
T
Y
S
U
B
M
I
T
T
A
L
04
/
0
6
/
2
0
2
3
2N
D
C
I
T
Y
S
U
B
M
I
T
T
A
L
06
/
1
6
/
2
0
2
3
3R
D
C
I
T
Y
S
U
B
M
I
T
T
A
L
08
/
2
8
/
2
0
2
3
4T
H
C
I
T
Y
S
U
B
M
I
T
T
A
L
09
/
1
3
/
2
0
2
3
5T
H
C
I
T
Y
S
U
B
M
I
T
T
A
L
12
/
1
9
/
2
0
2
2
5
:
0
0
:
1
3
P
M
FO
R
D
P
R
O
C
E
N
T
E
R
13
5
0
S
E
S
t
o
n
e
R
i
d
g
e
D
r
i
v
e
,
W
a
u
k
e
e
,
I
o
w
a
5
0
2
6
3
L:
\
L
A
N
D
P
R
O
J
E
C
T
S
2
0
2
2
\
2
2
0
3
2
8
\
D
W
G
\
C
6
D
E
T
A
I
L
S
.
D
W
G
9/
1
3
/
2
0
2
3
1
:
5
8
:
2
1
P
M
C6.2
DETAILS
SHEET
DETAIL 'B'
SCALE: 1'=10"
DETAIL 'A'
SCALE: 1'=10"
DETAIL 'C'
SCALE: 1'=10"
DETAIL 'D'
SCALE: 1'=10"
SUDAS RIP RAP DETAIL
SCALE NONE
2
C6.2
DURASLOT DRAIN DETAIL
SCALE NONE
3
C6.2
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
#
IS
S
U
E
D
A
T
E
NB
I
#
:
-
-
-
-
-
-
-
-
DB
S
#
:
2
2
-
3
-
4
4
2
DR
A
W
N
B
Y
:
G
S
A
CH
E
C
K
E
D
B
Y
:
S
V
S
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
#
IS
S
U
E
D
A
T
E
ST
I
V
E
R
S
GE
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
-
A
R
C
H
I
T
E
C
T
14
3
5
o
h
i
o
s
t
r
e
e
t
/
p
.
o
.
b
o
x
1
3
1
5
/
d
e
s
m
o
i
n
e
s
,
i
a
5
0
3
0
5
-
1
3
1
5
ph
o
n
e
:
(
5
1
5
)
2
4
3
-
0
1
5
6
/
f
a
x
:
(
5
1
5
)
2
4
3
-
0
1
6
5
NE
U
M
A
N
N
B
R
O
T
H
E
R
S
,
I
N
C
.
-
D
E
S
I
G
N
B
U
I
L
D
S
O
L
U
T
I
O
N
S
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Copyright DesignBuild Solutions, LC. Protected under Architectural Works Copyright Protection Act of 1990.
FIELD BULLETINS
ASSOCIATED WITH
THIS SHEET:
01
/
1
1
/
2
0
2
3
1S
T
C
I
T
Y
S
U
B
M
I
T
T
A
L
04
/
0
6
/
2
0
2
3
2N
D
C
I
T
Y
S
U
B
M
I
T
T
A
L
06
/
1
6
/
2
0
2
3
3R
D
C
I
T
Y
S
U
B
M
I
T
T
A
L
08
/
2
8
/
2
0
2
3
4T
H
C
I
T
Y
S
U
B
M
I
T
T
A
L
09
/
1
3
/
2
0
2
3
5T
H
C
I
T
Y
S
U
B
M
I
T
T
A
L
12
/
1
9
/
2
0
2
2
5
:
0
0
:
1
3
P
M
FO
R
D
P
R
O
C
E
N
T
E
R
13
5
0
S
E
S
t
o
n
e
R
i
d
g
e
D
r
i
v
e
,
W
a
u
k
e
e
,
I
o
w
a
5
0
2
6
3
L:
\
L
A
N
D
P
R
O
J
E
C
T
S
2
0
2
2
\
2
2
0
3
2
8
\
D
W
G
\
C
6
D
E
T
A
I
L
S
.
D
W
G
9/
1
3
/
2
0
2
3
1
:
5
8
:
3
0
P
M
C6.3
DETAILS
SHEET
RAIN GUARDIAN TYPICAL DETAIL
SCALE NONE
1
C6.3
INSPECTION/MAINTENANCE NOTE:
1.OWNER TO HIRE AND/OR PERFORM ANNUAL
INSPECTION AND MAINTENANCE OF MODIFIED
OUTLET STRUCTURE. THIS MAY INCLUDE BUT IS
NOT LIMITED TO REMOVAL/CLEANING OF ALL
DEBRIS, SILT AND TRASH ACCUMULATED IN THE
BASIN AND MODIFIED OUTLET STRUCTURES.
2.IF ANY PROLONGED PONDING OR DEBRIS IS
OBSERVED IN THE BASIN, THE OWNER SHALL
PERFORM MAINTENANCE ON A MODIFIED
SCHEDULE AS NEEDED TO KEEP THE BASIN CLEAR
OF DEBRIS, SILT AND TRASH.
PROP. BUILDING
PROP. 34,150 SQ. FT.
FF=1023.50'
HT.=23.00
WV
A/
C
FF=1023.50
(PER 2018 DESIGN
REF. PROJECT #180108)
HY
D
HYD
HY D
10
1
9
10
2
0
1
0
3
0
1022
102
2
10
2
3
1022
1018
1
0
2
8
10
2
8
1018
1020
10221022
1
0
3
1
1
0
3
2
D
D
1
0
2
2
1
0
2
1
10
2
0
10
2
1
1
0
2
2
1
0
2
5
CO
CO CO
CO
PROPOSED LOT 1
AREA = 110,122.89
PROPOSED LOT 2
AREA = 220,398.72 SF
WILLI
A
M
S
P
O
I
N
T
E
P
L
A
T
1
6
WILLI
A
M
S
P
O
I
N
T
E
P
L
A
T
1
6
CO
1
0
1
9
10
2
2
1024
1
0
2
2
CO
CO
S
COCO CO
CO
CO CO
10
2
3
10
2
3
10
2
1
1021
102
2
1
0
2
2
1023
1023
1
0
2
2
10
2
3
1
0
2
3
102
3
10
1
9
1018
1021
1020
1022
1020
1
0
2
2
1020
1020
1022
1024
1023
1018
1020
1023
1
0
2
5
1022
CO
CO
1
0
2
3
1
0
2
4
1
0
2
5
1
0
2
6
1
0
2
7
1018
1018
1021
10
2
2
10
2
0
1
0
2
3
1023
10
2
3
10
1
9
10
2
5
1
0
2
7
1
0
2
9
1025
10
2
9
10
2
2
1022
10
2
3
1
0
2
3
1022
1022
1022
1
0
2
9
1022
10
2
2
1023
10
3
0
103
1
10
2
9
10
2
8
102
6
1027
10
2
8
1024
1023
1022
1021
1020
10
2
3
10
2
3
D
WV
H Y D
F/OF/O
F/OFO
D
D
WV
H Y D
F/O
WV
WV
WV
H Y D
FO
D
SS
D
F/OT
F/O
ST
15"
SE
B
R
I
C
K
D
R
I
V
E
(C
O
N
C
R
E
T
E
P
U
B
L
I
C
R
O
A
D
-
8
0
'
R
.
O
.
W
.
)
SE STONE RIDGE DR
(CONCRETE PUBLIC ROAD - 70' R.O.W.)
F/O
F/O F/O F/O F/O F/O F/O F/O
F/
O
F/
O
F/
O
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
TE
L
E
U
/
E
U
/
E
U/E U/E U/E U/E U/E
U/
E
U/
E
U/
E
U/E U/E U/E U/E U/E U/E U/E U/E
U/E
U/
E
U/
E
U/
E
U/E
U/E U/E U/E
U/E
U/E U/E U/E
U/E
U/E U/E U/E
ST 15"ST 15"ST 15"ST 18"ST 18"ST 18"ST 18"ST 42"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
ST
36
"
D
ST 48"ST 48"ST 48"ST 48"
SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"SAN 8"
W12
"
W12
"
W
12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W12
"
W 12"W 12"W12"W12"W12"W12"W 12"W12"W 12"W12"W12"W12"W12"W12"
W6"
W6"
W6"
W 6"
W 6"
W
6
"
D
ST
8"
ST
8"
S
T
8
"
ST 15"
ST
18
"
G 2"G 2"G 2"G 2"G 2"G 2"G 2"G 2"G 2"G 2"
G
2"
G 2"G 2"G 2"G 2"
G
G
SA
N
8"
WV
W8"W8"W8"W8"
ST
42
"
ST
42
"
ST
42
"
D
ST
42"
ST
8"
ST
8"
ST
15"
S
T
1
5
"
D
102
7
1028
1
0
2
6
1025
1
0
2
6
1
0
2
7
1
0
2
9
1
0
3
0
1
0
3
1
1
0
3
0
10
2
9
10
2
5
1020
1017
10
1
7
10
2
0
10
2
5
1
0
2
1
102
1
102
2
10
2
2
10
2
5
1023
10
2
3
1
0
2
4
1
0
2
3
1025
10
2
5
10
2
5
10
2
3
1
0
2
0
1
0
1
9
1017
1
0
2
0
1
0
2
1
1
0
2
2
10
2
2
1
0
2
0
102210
2
3
1
0
2
5
10
3
1
10
3
0
10
2
9
1
0
2
8
1
0
2
7
10
2
4
10
2
3
1021
1020
101
9
101
8
10
1
7
1017
101
8
10
1
9
1019
1020
1021
10
2
2
1023
1022
10
2
3
10
2
3
10
2
3
1022
1
0
2
2
1020
1017
10
2
5
10
2
4
10
2
3
10
2
2
10
2
1
1
0
2
0
10
1
9
10
1
8
10
1
7
1
0
1
8
1
0
1
9
10
2
2
10
2
4
1
0
2
3
10
2
3
102
4
1
0
2
3
10
2
3
1022
1022
10
2
3
10
2
2
10
3
1
100 YEAR PONDING
ELEV. = 1020.48
STAGING
AREA
SF
SF
TEMP. INLET
PROTECTION
(TYP.)
STABILIZED CONSTRUCTION
ENTRANCE. 12" DEPTH ROCK, CLASS
A ROAD STONE.
(REF. DETAILS ON THIS SHEET)
SILT FENCE
(TYP.)
SF SF SF SF
SF
SF
S
F SF
SF
S
F
TO
P
S
O
I
L
ST
O
C
K
P
I
L
E
SILT FENCE
(TYP.)
DISTURBANCE LIMITS
CONTRACTOR OUTHOUSE,
DUMPSTER & CONC. WASHOUT
(REF. DETAILS ON THIS SHEET)
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SFSF
SF
TEMP. INLET
PROTECTION
(TYP.)
TEMP. INLET
PROTECTION
(TYP.)
TEMP. INLET
PROTECTION
(TYP.)
TEMP. INLET
PROTECTION
(TYP.)
SF
SF
SF
SF
SF
SF SF
SF
SF
SF
SILT FENCE TO BE INSTALLED
AT BIO-SWALE TOE OF SLOPE
TO PREVENT EROSION.
SF
SF
TEMP. INLET
PROTECTION
(TYP.)
SF
SF SF
SF
SILT FENCE
(TYP.)
SF SF
SF SF
SF SF
SILT FENCE
(TYP.)
SILT FENCE
(TYP.)
SF
SF
SF
SF
SF
SILT FENCE
(TYP.)
SILT FENCE
(TYP.)
SF SF SF SF SF SF SF SF SF SFSFSFSFSF
SILT SOCK ALONE BC OF
SE STONE RIDGE DR.
SF
SF
TEMP. INLET
PROTECTION
(TYP.)
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SILT SOCK
ALONG BC OF
SE BRICK DR.
SILT SOCK
(TYP.)
ULTIMATE DISCHARGE:
KEEP FLOWING NORTH THROUGH
PUBLIC SYSTEM TO AN UNNAMED
TRIBUTARY TO WALNUT CREEK IN
DALLAS COUNTY
DISCHARGE
POINT
SF
SF
SF
SF
TEMP. INLET
PROTECTION
(TYP.)
SILT SOCK ALONE BC OF
SE STONE RIDGE DR.
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
BIORETENTION PERIMETER
FINISHED GRADE ELEVATION=1018.50
AREA=1,745 SF
POST CONSTRUCTION FACILITY
BIORETENTION PERIMETER
FINISHED GRADE ELEVATION=1018.00
AREA=1,520 SF
POST CONSTRUCTION FACILITY
BIORETENTION PERIMETER
FINISHED GRADE ELEVATION=1018.00
AREA=2,182 SF
POST CONSTRUCTION FACILITY
SF
SF
SF
SF
SF
SF
SF
SF
S
F
S
F
SF
SF
BIORETENTION PERIMETER -
POST CONSTRUCTION FACILITY
TEMP. INLET
PROTECTION
(TYP.)
SF SF
SFSFSF
SILT FENCE
(TYP.)
SF SF SF SF SF SF SF SF
SFSFSFSFSFSF
SILT FENCE
(TYP.)
RAIN GUARDIAN TURRET -
POST CONSTRUCTION FACILITY
RAIN GUARDIAN TURRET -
POST CONSTRUCTION FACILITY
SUMP INTAKE -
POST
CONSTRUCTION
FACILITY
SUMP INTAKE -
POST
CONSTRUCTION
FACILITY
SUMP INTAKE -
POST
CONSTRUCTION
FACILITY
SUMP INTAKE -
POST
CONSTRUCTION
FACILITY
SUMP INTAKE -
POST
CONSTRUCTION
FACILITY SUMP INTAKE -
POST
CONSTRUCTION
FACILITY
SUMP INTAKE -
POST
CONSTRUCTION
FACILITYSUMP INTAKE -
POST
CONSTRUCTION
FACILITY
6
SITE
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
#
IS
S
U
E
D
A
T
E
NB
I
#
:
-
-
-
-
-
-
-
-
DB
S
#
:
2
2
-
3
-
4
4
2
DR
A
W
N
B
Y
:
G
S
A
CH
E
C
K
E
D
B
Y
:
S
V
S
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
#
IS
S
U
E
D
A
T
E
ST
I
V
E
R
S
GE
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
-
A
R
C
H
I
T
E
C
T
14
3
5
o
h
i
o
s
t
r
e
e
t
/
p
.
o
.
b
o
x
1
3
1
5
/
d
e
s
m
o
i
n
e
s
,
i
a
5
0
3
0
5
-
1
3
1
5
ph
o
n
e
:
(
5
1
5
)
2
4
3
-
0
1
5
6
/
f
a
x
:
(
5
1
5
)
2
4
3
-
0
1
6
5
NE
U
M
A
N
N
B
R
O
T
H
E
R
S
,
I
N
C
.
-
D
E
S
I
G
N
B
U
I
L
D
S
O
L
U
T
I
O
N
S
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Copyright DesignBuild Solutions, LC. Protected under Architectural Works Copyright Protection Act of 1990.
FIELD BULLETINS
ASSOCIATED WITH
THIS SHEET:
01
/
1
1
/
2
0
2
3
1S
T
C
I
T
Y
S
U
B
M
I
T
T
A
L
04
/
0
6
/
2
0
2
3
2N
D
C
I
T
Y
S
U
B
M
I
T
T
A
L
06
/
1
6
/
2
0
2
3
3R
D
C
I
T
Y
S
U
B
M
I
T
T
A
L
08
/
2
8
/
2
0
2
3
4T
H
C
I
T
Y
S
U
B
M
I
T
T
A
L
09
/
1
3
/
2
0
2
3
5T
H
C
I
T
Y
S
U
B
M
I
T
T
A
L
12
/
1
9
/
2
0
2
2
5
:
0
0
:
1
3
P
M
FO
R
D
P
R
O
C
E
N
T
E
R
13
5
0
S
E
S
t
o
n
e
R
i
d
g
e
D
r
i
v
e
,
W
a
u
k
e
e
,
I
o
w
a
5
0
2
6
3
GRAPHIC SCALE
040 20 40 80
STORM WATER POLLUTION PREVENTION PLAN
VICINITY MAP
NOT TO SCALE
IOWAONE CALL
1-800-292-8989
www.iowaonecall.com
811
Know what's below.
Call before you dig.
UTILITY NOTE:
THE LOCATION OF THE UTILITIES INDICATED ON THE PLANS ARE TAKEN FROM
EXISTING PUBLIC RECORDS AND ARE APPROXIMATE LOCATIONS. THE EXACT
LOCATIONS OF ALL UTILITIES MUST BE ASCERTAINED IN THE FIELD. IT SHALL BE
THE DUTY OF THE CONTRACTOR TO DETERMINE WHETHER ANY ADDITIONAL
FACILITIES OTHER THAN THOSE SHOWN ON THE PLANS MAY BE PRESENT.
LEGEND:
120 EXISTING CONTOUR
120 PROPOSED CONTOUR
SF SILT FENCE
SAN SANITARY SEWER
ST STORM SEWER
W WATER LINE
G GAS LINE
U/E UNDERGROUND ELECTRIC
O/E OVERHEAD ELECTRIC
TELE TELEPHONE LINE
F/O FIBER OPTIC
CATV CABLE TV
STORM MANHOLE
CURB INTAKE
SURFACE INTAKE
FLARED END SECTION
SANITARY MANHOLE
CLEANOUT
FIRE HYDRANT
SPRINKLER
IRRIGATION CONTROL VALVE
WATER MANHOLE
WELL
WATER VALVE
WATER SHUT OFF
YARD HYDRANT
ELECTRIC MANHOLE
ELECTRIC METER
ELECTRIC RISER
ELECTRIC VAULT
POWER POLE
TRANSFORMER POLE
LIGHT POLE
ELECTRIC JUNCTION BOX
ELECTRIC PANEL
TRANSFORMER
GROUND LIGHT
GUY WIRE
ELECTRIC HANDHOLE
GAS METER
GAS VALVE
AIR CONDITIONING UNIT
TELEPHONE RISER
TELEPHONE VAULT
TELEPHONE MANHOLE
TRAFFIC SIGNAL MANHOLE
FIBER OPTIC RISER
FIBER OPTIC FAULT
CABLE TV RISER
SIGN
D
S
CO
H Y D
I CV
W
WS O
Y
A DR
E
EM
E
ELEC
EJ
EP
GM
GV
A/C
T
TEL
T
TS
FO
F/O
TV
W
WV
NOT TO SCALE
SITE ENTRANCE DETAIL
TEMP. ROCK ENTRANCE
(PLAN VIEW)
(PROFILE VIEW)
TEMP. ROCK ENTRANCE
3" CLEAN
LIMESTONE
PLACE ROCK
ON FABRIC
STABILIZED ENTRANCE SHALL BE AT
LEAST 50' LONG AND EXTEND TO THE
PUBLIC ROADWAY.
5'
-
0
"
M
I
N
.
GROUND LINE
ENGINEERING FABRIC
FLOW
2
1' ABOVE GROUND LINE VARIABLE
10' MAX.5' MAX.5' MAX.10' MAX.
1' ABOVE GROUND LINE
SECURE TOP OF ENGINEERING FABRIC
ENGINEERING FABRIC TO BE PLACED
TO BOTTOM OF TRENCH.
1
2
ENGINEERING
FABRIC
GROUND
LINE
TRENCH BOTTOM
TRENCH BOTTOM
1 1
1
LINE
GROUND
1
MIN.
4"
EXCESS FABRIC
COMPACTED BACKFILL
12
"
MI
N
.
DETAIL OF SILT FENCE AT DITCH OR SWALE
DETAIL OF SILT FENCE
8' SPACING
TO TOP OF STEEL POST.
SEE DETAIL OF ATTACHMENT TO POST.
VERTICAL CUT
WIRE
CORD
CORD
CORD
WIRE
POST
FABRIC
FABRIC
BACK VIEW OF FABRIC
BACK VIEW
ATTACHMENT TO POST
3
4
NOTES :
3 MAKE VERTICAL CUT IN TOP OF FABRIC.
PULL OUT AND TWIST CORD.
4 LOOP CORD AROUND POST FORMING A
LOOP. PULL WIRE THROUGH FOLD AREA
OF FABRIC AND SECURE AROUND POST.
'T' STEEL
FENCE POST
NORMAL
FORESLOPE
2" RISE
IN FENCE
31"
MIN.
NORMAL BACKSLOPE
31
"
M
I
N
.
6" TRENCH DEPTH FOR
NORMAL INSTALLATION
(MIN.) 12" TRENCH
DEPTH FOR DITCH
INSTALLATION
NOT TO SCALE
(SECTION VIEW)
(PROFILE VIEW)
SILT FENCE DETAILS
NOT TO SCALE
INLET
5'-0"
5'-0"
'T' FENCE POST, 5' MIN.
NOTES:
1. SECURE TOP OF FABRIC TO
POSTS, USING CABLE TIES OR
WIRE.
2. FABRIC TO BE BURIED 12", AND
FOLDED ALONG BOTTOM.
3. STEEL POSTS TO BE EMBEDDED
28".
(PLAN VIEW)
DROP INLET BASKET
PROTECTION
SILT FENCE FABRIC
IF APPLICABLE
INLET PROTECTION DETAIL
NOT TO SCALE
NOTES:
1. 1 C.Y. CONCRETE BAG SHALL BE REQUIRED AT ANY
LOCATION WHERE CONCRETE IS USED.
2. CONCRETE WASHOUT DUMPSTER W/ HEAVY DUTY
LINER IS AN ACCEPTIBLE ALTERNATIVE
(PLAN VIEW)
1 C.Y. CONCRETE
WASH-OUT BAG
'T' FENCE POST
5' MIN
CONCRETE WASH-OUT BAG DETAIL
(PROFILE VIEW)
1 C.Y. CONCRETE
WASH-OUT BAG
L:
\
L
A
N
D
P
R
O
J
E
C
T
S
2
0
2
2
\
2
2
0
3
2
8
\
D
W
G
\
C
7
S
W
P
P
P
.
D
W
G
9/
1
3
/
2
0
2
3
1
:
5
8
:
5
6
P
M
PROPERTY DESCRIPTION:
QUIT CLAIM DEED BOOK: 2015 PAGE: 20587
LOTS 2, 3, 4, 5, 6 AND 7, IN WILLIAMS POINTE PLAT 14, AN
OFFICIAL PLAT, NOW INCLUDED IN AND FORMING A PART OF
THE CITY OF WAUKEE, DALLAS COUNTY, IOWA.
SAID TRACT OF LAND SUBJECT TO ALL EASEMENTS AND
ENCUMBRANCES OF RECORD.
SUBJECT TO AND TOGETHER WITH ANY AND ALL
EASEMENTS AND RESTRICTIONS OF RECORD.
AREA:
330,521 SQUARE FEET - 7.58 ACRES
SAID TRACT OF LAND CONTAINS 7.58 ACRES (330,521 SF)
MORE OR LESS.
ADDRESS:
1350 SE STONE RIDGE DR
WAUKEE, IOWA 50263
OWNER:
STIVERS IOWA REAL ESTATE LLC
1450 EAST HICKMAN ROAD
WAUKEE, IOWA 50263
PREPARED FOR:
STIVERS IOWA REAL ESTATE LLC
1450 EAST HICKMAN ROAD
WAUKEE, IOWA 50263
ZONING:
INFORMATION OBTAINED FROM
THE CITY OF WAUKEE ZONING MAP
ZONED: C-1 (COMMUNITY AND HIGHWAY SERVICE
COMMERCIAL DISTRICT)
AND PD (PLANNED DEVELOPMENT DISTRICT)
FOR AN OFFICIAL ZONING REPORT PLEASE CALL CITY OF
WAUKEE AT (515) 978-9533
SITE CONTROL AND BENCHMARKS:
BASIS OF BEARING OBTAINED FROM GPS OBSERVATIONS
DATUM = NAD 83, IOWA SOUTH
BENCHMARK DATUM = NAVD88, GEOID 18
POINT #100, 3/4" IRON PIPE W/ YELLOW PLASTIC CAP
NORTHING = 587,608.16
EASTING = 1,545,183.16
ELEVATION = 1032.78
DESCRIPTION: WEST OF S.W. CORNER, LOT 7
POINT #9011, 3/4" IRON PIPE W/ RED PLASTIC CAP
NORTHING = 588,181.34
EASTING = 1,545,646.71
ELEVATION = 1019.82
DESCRIPTION: NORTH OF N.E. CORNER, LOT 3
EROSION CONTROL NOTES:
1.SEE SUPPLEMENTAL DETAIL STORM WATER POLLUTION PLAN NARRATIVE FOR ALL EROSION CONTROL MEASURES, ADDITIONAL DETAILS AND NOTE. ADDITIONAL NOTES AND
MEASURES IN NARRATIVE SHALL BE CONSIDERED INCIDENTAL AND SHALL BE INCLUDED IN THE ORIGINAL BID.
2.SWPPP PLAN AND NARRATIVE ARE CONSIDERED A LIVING DOCUMENT AND WILL NEED PERIODIC UPDATES AND ADJUSTMENTS AS NECESSARY DEPENDING ON SITE CONDITIONS TO
ASSURE COMPLIANCE WITH NPDES GENERAL PERMIT NO. 2. IT IS THE CONTRACTOR'S RESPONSIBILITY TO UPDATE THE SWPPP AND IMPLEMENT ANY AND ALL MEASURES NECESSARY
TO COMPLY WITH SAID PERMIT NO. 2.
3.INSTALL PERIMETER SILT FENCE AS SHOWN ON PLANS PRIOR TO CONSTRUCTION.
4.INSTALL INTAKE PROTECTION WITH SILT FENCE IMMEDIATELY AFTER STORM SEWER CONSTRUCTION.
5.INSTALL FINISHED PAVING INLET PROTECTION IMMEDIATELY AFTER PAVING IS COMPLETED AROUND INTAKE.
6.OTHER EROSION CONTROL TYPES MAY NOT BE SUBSTITUTED FOR SILT FENCE.
7.CONTRACTOR SHALL BE RESPONSIBLE FOR SUPPLYING A CONCRETE WASHOUT IN ACCORDANCE WITH SUDAS SPEC 11,050 DURING ALL CONCRETE WORK.
8.CONTRACTOR SHALL BE RESPONSIBLE FOR SUPPLYING TEMPORARY RESTROOM FACILITIES. SANITARY WASTE SHALL BE DISPOSED OF PER ALL FEDERAL, STATE AND LOCAL
REGULATIONS.
9.CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING ALL TOPSOIL REQUIREMENTS OF NPDES GENERAL PERMIT NO. 2 ARE MET.
10.CONTRACTOR SHALL BE RESPONSIBLE FOR REVISING AND/OR INSTALLING ADDITIONAL EROSION CONTROL MEASURES/SEEDING AS NEEDED TO ACCOMMODATE THE CONSTRUCTION
PHASING AND SWPPP INSPECTOR REQUIREMENTS. SUCH CHANGES SHALL BE INCIDENTAL TO THE PROJECT. ALL CHANGES SHALL BE DOCUMENTED AND RECORDED.
11.THIS PROJECT INCLUDES SAWCUTTING OR CONCRETE GRINDING SO PROTECTION OF STORM SEWERS AND DRAINAGE WAYS WILL NEED TO BE PROVIDED FROM SLURRY FROM THE
CONCRETE OPERATIONS TO DISCHARGE OFFSITE. SEE SWPPP SHEET AND NARRATIVE FOR ADDITIONAL DETAILS.
12.CONTRACTOR SHALL PROVIDE APPROPRIATE CONTROLS TO PREVENT DISCHARGES FROM ANY AND ALL DEWATERING ACTIVITIES.
13.SEE LANDSCAPE PLAN FOR FINAL STABILIZATION INCLUDING SEEDING AND SODDING AREAS.
14.PER NPDES GENERAL PERMIT NO. 2, IF CONSTRUCTION ACTIVITY IS NOT PLANNED FOR AT LEAST 14 DAYS, ALL DISTURBED AREAS SHALL BE STABILIZED IMMEDIATELY BY TEMPORARY
EROSION CONTROL MEASURES.
15.THE FOLLOWING DISCHARGES ARE PROHIBITED: WASTEWATER FROM WASHOUT AND CLEANOUT OF STUCCO, PAINT, FORM RELEASE OIL, CURING COMPOUNDS AND OTHER
CONSTRUCTION MATERIALS, FUEL, OILS OR OTHER POLLUTANTS USED IN VEHICLE AND EQUIPMENT OPERATION AND MAINTENANCE, AND SOAPS OR SOLVENTS USED IN VEHICLE AND
EQUIPMENT WASHING.
16.CONTRACTOR IS RESPONSIBLE FOR INSTALLING AND PHASING EROSION CONTROLS AND SILT FENCE, PER SWPPP INSPECTORS RECOMMENDATIONS, TO MAINTAIN EROSION
PROTECTION AND ACCOMMODATE CONSTRUCTION ACTIVITIES AND PHASING. ANY ADDITIONAL EROSION CONTROLS OR ADJUSTMENTS SHALL BE INCIDENTAL.
17.CONTRACTOR IS RESPONSIBLE FOR CORRECTING ANY SILTING, REELING OR SCOURING TO DESIGN GRADE BEFORE CLOSE OF PROJECT PER SWPPP INSPECTOR AND OWNER
RECOMMENDATIONS.
18.CONTRACTOR TO PROTECT PROPOSED PONDS DURING CONSTRUCTION FROM EROSION AND SILTING. ANY CORRECTIVE WORK TO RESTORE POND BOTTOMS SHALL BE INCIDENTAL.
DISTURBED AREA = 4.7 ACRES±
STABILIZED ENTRANCE AT LEAST 50'
LONG-12" DEEP CLASS "A" ROAD STONE
ON GEOTEXTILE
120
SILT FENCE (TYP)
LEGEND:
EXISTING CONTOUR
PROPOSED CONTOUR120
SFSF SF
GRADING LEGEND:
EXISTING CONTOUR
PROPOSED CONTOUR
FINISHED GROUND ELEVATION
TOP OF CURB ELEVATION
GUTTER ELEVATION
TOP OF WALL ELEVATION
BOTTOM OF WALL ELEVATION
EDGE OF WALK ELEVATION
TOP OF STAIR ELEVATION
BOTTOM OF STAIR ELEVATION
NOTE: WALL ELEVATIONS SHOWN ON PLAN ARE FINISHED
GROUND GRADES AT THE TOP AND BOTTOM OF THE WALL.
150.50E/W
150.50B/W
150.50T/W
150.50G
150.50T/C
150.50
150
150
150.50T/S
150.50B/S
C7.1
SWPPP
EROSION CONTROL REMOVAL NOTES:
1.AFTER FINAL STABILIZATION HAS OCCURED, AS DEFINED IN NPDES GENERAL PERMIT NO. 2,
CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL TEMPORARY EROSION
CONTROL DEVICES INCLUDING, BUT NOT LIMITED TO: SILT FENCE, INLET PROTECTION, AND
TEMPORARY STANDPIPES.
QUANTITY ESTIMATE:
EROSION CONTROL:
INLET PROTECTION 22 EA
SILT FENCE 2,300 LF
SOD 91,040 SF
RIP RAP CLASS "E" W/ ENGINEERING FABRIC 146 TONS
CURB LINE SILT SOCK 900 LF
TEMPORARY SEEDING (SUDAS TYPE 4)AS NECESSARY
NOTE: EROSION CONTROL QUANTITIES ARE PROVIDED FOR CITY REQUIREMENT ONLY AND ARE A
ROUGH ESTIMATE. CONTRACTOR SHALL PROVIDE EROSION CONTROL MEASURES AS NECESSARY TO
MEET SITE CONDITIONS.
GENERAL NOTES:
1.ALL BIORETENTION CELLS ARE TO BE CONSTRUCTED
ONLY AFTER ALL OTHER CONSTRUCTION ITEMS ARE
COMPLETE. SEDIMENT PROTECTION WILL BE
REQUIRED IF IMMEDIATE UPSTREAM PROTECTION IS
NOT ABLE TO BE COMPLETED.
25' PRIVATE SANITARY
SEWER EASEMENT
BK. 2007 PG. 15331
10' PUBLIC UTILITY EASEMENT
BK.2007 PG.15339
PRIVATE 15'
STORM SEWER EASEMENT
BK. 2007 PG. 15336
30
'
P
R
I
V
A
T
E
IN
G
R
E
S
S
/
E
G
R
E
S
S
EA
S
E
M
E
N
T
BK
.
2
0
0
7
P
G
.
1
5
3
3
3
30
'
P
R
I
V
A
T
E
IN
G
R
E
S
S
/
E
G
R
E
S
S
EA
S
E
M
E
N
T
BK
.
2
0
0
7
P
G
.
1
5
3
3
3
25' PUBLIC STORM SEWER
AND OVERLAND
FLOWAGE EASEMENT
BK. 2007 PG. 15337
1
5
'
P
R
I
V
A
T
E
S
T
O
R
M
S
E
W
E
R
E
A
S
E
M
E
N
T
B
K
.
2
0
0
7
P
G
.
1
5
3
3
6
PRIVATE 15'
STORM SEWER
EASEMENT
BK. 2007 PG. 15329
15
'
P
R
I
V
A
T
E
W
A
T
E
R
M
A
I
N
E
A
S
E
M
E
N
T
BK
.
2
0
0
7
P
G
.
1
5
3
3
2
10' PUBLIC UTILITY EASEMENT
BK.2007 PG.15339
7.
5
'
P
U
B
L
I
C
S
T
O
R
M
SE
W
E
R
E
A
S
E
M
E
N
T
BK
.
2
0
0
7
P
G
.
1
5
3
3
8
65
'
P
R
I
V
A
T
E
O
V
E
R
L
A
N
D
FL
O
W
A
G
E
A
N
D
D
E
T
E
N
T
I
O
N
EA
S
E
M
E
N
T
BK
.
2
0
0
7
P
G
.
1
5
3
2
8
30' PRIVATE
INGRESS/EGRESS
EASEMENT
BK. 2007 PG. 15333
2
220399 SF
5.06 AC
1
110123 SF
2.53 AC
426.36'
51
6
.
3
6
'
S
0
0
°
2
0
'
0
6
"
W
402.83'188.51'
32' INGRESS/EGRESS
EASEMENT
79
.
0
0
'
S0
0
°
2
0
'
0
6
"
W
32.00'
N89°49'20"W
79
.
0
0
'
N0
0
°
2
0
'
0
6
"
E
213.57'
R=25.00' Δ=90°05'55"
L=39.31' CH=35.39'
S45°08'51"W
R=25.00' Δ=89°44'44"
L=39.16' CH=35.28'
N44°44'27"W
OWNER: FORE RIGHT LC
ZONED: C-1 COMMERCIAL DISTRICT & PD (PLANNED
DEVELOPMENT)
SE
B
R
I
C
K
D
R
I
V
E
PU
B
L
I
C
R
O
A
D
-
8
0
'
R
.
O
.
W
.
SE STONE RIDGE DR
PUBLIC ROAD-70' R.O.W.
SE
W
A
C
O
P
L
A
C
E
PU
B
L
I
C
R
O
A
D
-
1
0
0
'
R
.
O
.
W
.
LOT 1
(S89°52'00"E 591.33')
(N89°52'00"W 640.05')
(S
0
0
°
2
0
'
5
8
"
W
4
9
0
.
8
6
'
)
(S
0
0
°
1
6
'
6
5
"
W
4
9
1
.
3
7
'
)
(R=25.00 L=39.27 CH=35.36
S45°08'00"W)(R=25.00 L=39.33 CH=35.40
N44°47'33"W)
(N
0
0
°
0
8
'
0
0
"
E
1
2
0
.
0
0
'
)
(S
0
0
°
1
6
'
5
5
"
W
1
2
0
.
0
0
)
(N89°52'00"W 80.00')
15.50'
OWNER: ALICE PLACE LP
ZONED: R-3 (RENTAL MULTI-FAMILY RESIDENTIAL
DISTRICT) & PD (PLANNED DEVELOPMENT)
LOT 2
10
'
P
U
B
L
I
C
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
BK
.
2
0
0
7
P
G
.
1
5
3
3
9
23
4
.
2
7
'
(TO BE VACATED)
(TO BE VACATED)
(T
O
B
E
V
A
C
A
T
E
D
)
(T
O
B
E
V
A
C
A
T
E
D
)
(T
O
B
E
V
A
C
A
T
E
D
)
(TO BE VACATED)
PRIVATE
WATERMAIN
EASEMENT
32
.
0
0
'
N0
0
°
2
0
'
0
6
"
E
30.00'
S89°48'24"E
30.00'
N89°48'24"W
32
.
0
0
'
S0
0
°
2
0
'
0
6
"
W
6
SITE
FI
N
A
L
P
L
A
T
1 OF 1
35
0
1
1
0
4
t
h
S
t
r
e
e
t
De
s
M
o
i
n
e
s
,
I
o
w
a
5
0
3
2
2
-
3
8
2
5
Ph
o
n
e
:
(
5
1
5
)
2
7
6
-
0
4
6
7
F
a
x
:
(
5
1
5
)
2
7
6
-
0
2
1
7
"P
l
a
n
n
i
n
g
Y
o
u
r
S
u
c
c
e
s
s
f
u
l
D
e
v
e
l
o
p
m
e
n
t
"
Bi
s
h
o
p
E
n
g
i
n
e
e
r
i
n
g
Ci
v
i
l
E
n
g
i
n
e
e
r
i
n
g
&
L
a
n
d
S
u
r
v
e
y
i
n
g
E
s
t
a
b
l
i
s
h
e
d
1
9
5
9
WI
L
L
I
A
M
S
P
O
I
N
T
E
P
L
A
T
1
6
WA
U
K
E
E
,
I
O
W
A
220328
GRAPHIC SCALE
040 20 40 80
\\
B
E
-
S
E
R
V
\
P
R
O
J
E
C
T
S
2
\
L
A
N
D
P
R
O
J
E
C
T
S
2
0
2
2
\
2
2
0
3
2
8
\
D
W
G
\
F
I
N
A
L
P
L
A
T
.
D
W
G
9/
1
4
/
2
0
2
3
1
:
3
1
:
2
3
P
M
WILLIAMS POINTE PLAT 16
FINAL PLAT
ZONING:
ZONED: C-1 - COMMUNITY AND HIGHWAY SERVICE COMMERCIAL
DISTRICT / PD-1 - PLANNED DEVELOPMENT OVERLAY
FRONT YARD SETBACK: 25 FT
SIDE YARD SETBACK: NONE
REAR YARD SETBACK: 25'
VICINITY MAP
SCALE: 1' = 1,000'
COPYRIGHT 2023 BISHOP ENGINEERING. THIS DOCUMENT AND THE INFORMATION CONTAINED MAY NOT BE
REPRODUCED OR EXCERPTED WITHOUT THE EXPRESS WRITTEN PERMISSION OF BISHOP ENGINEERING.
UNAUTHORIZED COPYING OR DISCLOSURE OF CONSTRUCTION USE ARE PROHIBITED BY COPYRIGHT LAW.
LOCATION:
LOT 2, 3, 4, 5, 6, 7 IN WILLIAMS POINTE PLAT 14
REQUESTOR/OWNER:
STIVERS IOWA REAL ESTATE LLC
1450 EAST HICKMAN ROAD
WAUKEE, IOWA 50263
PREPARED BY & RETURN TO:
LARRY HYLER PLS
BISHOP ENGINEERING
3501 104TH ST
URBANDALE, IA 50322
INDEX LEGEND
ABBREVIATIONS:
AC ACRES
PUE PUBLIC UTILITY EASEMENT
TYP TYPICAL
N NORTH
S SOUTH
E EAST
W WEST
YPC YELLOW PLASTIC CAP
MPE MINIMUM PROTECTION ELEVATION
SF SQUARE FOOTAGE
POB POINT OF BEGINNING
POC POINT OF COMMENCEMENT
PROPERTY CORNER - FOUND AS NOTED
PROPERTY CORNER- PLACED 5/8" IRON ROD
WITH YELLOW PLASTIC CAP ID #14775
SECTION CORNER - FOUND AS NOTED
CUT "X" IN PAVEMENT
ADDRESS
PREVIOUSLY RECORDED
LEGEND:
NOTES:
THIS PLAT HAS AN ERROR OR CLOSURE OF LESS THAN 1.0 FEET IN 10,000.0 FEET. EACH LOT WITHIN
THIS PLAT HAS AN ERROR OF CLOSURE OF LESS THAN 1.0 FEET IN 5,000.0 FEET.
ALL CORNERS HAVE BEEN PLACED WITH A 5/8 INCH IRON PIPE UNLESS NOTED OTHERWISE. ALL
CORNERS PLACED HAVE A YELLOW PLASTIC IDENTIFICATION CAP NO. 14775.
LOTS 1 AND 2 HAVE A MINIMUM PROTECTION ELEVATION OF 1022.50 PER WILLIAMS POINTE PLAT 14
(XXX)
PROPERTY DESCRIPTION:
LOTS 2, 3, 4, 5, 6, AND 7 IN WILLIAMS POINTE PLAT 14, AN
OFFICIAL PLAT, WAUKEE, DALLAS COUNTY, IOWA.
SUBJECT TO AND TOGETHER WITH ANY AND ALL
EASEMENTS AND RESTRICTIONS OF RECORD.
SAID TRACT OF LAND CONTAINS 7.58 ACRES (330,521 SF)
MORE OR LESS.
1350
1300
SE STONE RIDGE DRIVE
SE STONE RIDGE DRIVE
FORD PRO CENTER - STIVERS
Level 1
0"
AEGC3
A300
D
14' - 0"
F9
A400
BC
6
1 13
3
9 16
14
13
13
15
ROOM EXHAUST -
SEE MECHANICAL
ROOM EXHAUST
LOCATION
6'-8"
D3
A301
F4
A510
F6
A510
D6
A510
A1
A510
C1
A510
4'-
0
"
5
4
21
'
-
6
7
/
1
6
"
D8
A510
F
25' - 4 7/16"
F1
A510
Level 1
0"
124567810
B3
A301
E3
A300
24' - 0"
5.19 3
78 9 15
314
13
11
B3
A300
4.1
A6
A510
A8
A510
F6
A510
A8
A510
D6
A510
6.1
15 15 15 15 15 15
F3
A300
Level 1
0"
1 2 4 5 6 7 8 10
24' - 0"23' - 10 1/2"
23' - 0 1/4"
5.1 93
15
14
2
10 87 6 5
1
4.1
6'-2"
DOMESTIC WATER SERVICEELECTRICAL SERVICE
6.1
8'-
1
"
6
11
9 15
3
4915151515
Level 1
0"
A E G
C3
A300
D
F7
A401
B C
24' - 0"
23' - 10 1/2"
23' - 1 1/4"
8
15
14
13
3
9 7 12MAKE UP AIR
UNIT - SEE
MECHANICAL
D3
A301
A6
A510
A8
A510
A8
A510
F4
A510
D6
A510
LOUVERS TO HAVE GRAY FINISH
F
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
#
I
S
S
U
E
D
A
T
E
NB
I
#
:
-
-
-
-
-
-
-
-
DB
S
#
:
2
2
-
3
-
4
4
2
DR
A
W
N
B
Y
:
C
H
E
C
K
E
D
B
Y
:
DE
S
C
R
I
P
T
I
O
N
IS
S
U
E
#
I
S
S
U
E
D
A
T
E
14
ST
I
V
E
R
S
GE
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
-
A
R
C
H
I
T
E
C
T
14
3
5
o
h
i
o
s
t
r
e
e
t
/
p
.
o
.
b
o
x
1
3
1
5
/
d
e
s
m
o
i
n
e
s
,
i
a
5
0
3
05
-
1
3
1
5
ph
o
n
e
:
(
5
1
5
)
2
4
3
-
0
1
5
6
/
f
a
x
:
(
5
1
5
)
2
4
3
-
0
1
6
5
NE
U
M
A
N
N
B
R
O
T
H
E
R
S
,
I
N
C
.
-
D
E
S
I
G
N
B
U
I
L
D
S
O
L
U
T
I
O
N
S
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Copyright DesignBuild Solutions, LC. Protected under Architectural Works Copyright Protection Act of 1990.
FIELD BULLETINS
ASSOCIATED WITH
THIS SHEET:
1/
0
6
/
2
0
2
3
B
U
D
G
E
T
S
E
T
(
8
0
%
D
D
)
NOT FOR CONSTRUCTION
1/
1
1
/
2
0
2
3
9
:
2
3
:
5
6
A
M
A200
EXTERIOR
ELEVATIONS
FO
R
D
P
R
O
C
E
N
T
E
R
.
.
13
5
0
S
E
S
t
o
n
e
R
i
d
g
e
D
r
i
v
e
,
W
a
u
k
e
e
,
I
o
w
a
5
0
2
6
3
ELEVATION KEYNOTES
MARK DESCRIPTION
1 HORIZONTAL CORRUGATED METAL PANEL, COLOR EQUIVALENT TO SHERWIN WILLIAMS SW7016 MINDFUL GREY:
METL-SPAN 7.2 PANEL
2 3" THICK X 36" WIDE INSULATED METAL WALL PANEL W/ 1/2" REVEAL - EQUIVALENT TO SW7016 MINDFUL GRAY
:METAL SPAN SMOOTH FACED DW-4000 W/ KYNAR FINISH AND MAX U-VALUE OF 0.048
3 3" THICK X 36" WIDE INSULATED METAL WALL PANEL W/ 1/2" REVEAL - SLATE GRAY: METAL SPAN SMOOTH FACED
DW-4000 W/ KYNAR FINISH AND MAX U-VALUE OF 0.048
4 FORD BLUE ACM WALL
5 CLEAR ANODIZED THERMAL BREAK STOREFRONT WITH 1" LOW E INSULATED GLASS EQUAL TO KAWNEER 600 SERIES
- U-VALUE OF GLAZING: 0.30 OR LOWER
6 MODULAR BRICK: INDULGENCE KLAYCOAT SERIES., STEEL GREY KLAYCOAT BY GLEN-GERY W/GLEN-GERY COLORED
MORTAR
7 INSULATED HOLLOW METAL OVERHEAD DOOR W/ INSULATED GLASS TOP PANEL. INSULATED PANEL EQUIVALENT TO
GAUNTLET GRAY SW 7019.
8 BOLLARD: 6" DIA GALV. STEEL BOLLARD, CONCRETE FILLED, PAINTED AND MOUNTED TO BUILDING FOOTING BELOW
9 2 5/16" CONCRETE INSULATED PANEL (WALLGUARD BY T-CLEAR OR EQUAL), SW7016 MINDFUL GRAY PAINT FINISH
10 2 5/16" CONCRETE INSULATED PANEL (WALLGUARD BY T-CLEAR OR EQUAL), SW7019 GAUNTLET GRAY PAINT FINISH
11 COLORED SPLIT FACE CONCRETE BLOCK W/ COLORED MORTAR
12 DUMPSTER GATE: COMPOSITE WOOD VERTICAL SLATS - STAINED & SEALED - ON METAL FRAMING MOUNTED ON
CONCRETE FILLED 6" GALVANIZED STEEL POST
13 RAKE FLASHING BY METAL BUILDING MFR.
14 PRE-FINISH ROOF GUTTER BY METAL BUILDING MFR.
15 PREFINISHED METAL DOWNSPOUT BY METAL BUILDING MFR. - CONNECTED TO SUBSURFACE DRAINAGE
16 INSULATED GLASS PANEL OVERHEAD DOOR W/ BOTTOM TWO PANELS TO BE INSULATED METAL TO MATCH "MINDFUL
GRAY" SW 7016
1/8" = 1'-0"A200
C1 WEST ELEVATION
1/8" = 1'-0"A200
D1 SOUTH ELEVATION
1/8" = 1'-0"A200
A1 NORTH ELEVATION
1/8" = 1'-0"A200
F1 EAST ELEVATION
Level 1
0"
1 2 4 5 6 7 8 10
24' - 0"23' - 10 1/2"
23' - 0 1/4"
5.1 93
15
14
2
10 817 6 5
1
4.1
6'-4"
DOMESTIC WATER SERVICEELECTRICAL SERVICE
6.1
8'-
1
"
6
11
9 15
3
4915151515
3
14' - 0"
1/8" = 1'-0"A200
A1 NORTH ELEVATION
Level 1
0"
A E G
C3
A300
D
F7
A401
B C
24' - 0"
23' - 10 1/2"
23' - 1 1/4"
8
15
14
13
3
9 7 12MAKE UP AIR
UNIT - SEE
MECHANICAL
D3
A301
A6
A510
A8
A510
A8
A510
F4
A510
D6
A510
LOUVERS TO HAVE GRAY FINISH
F
1/8" = 1'-0"A200
F1 EAST ELEVATION